WorldWideScience

Sample records for computed tomography angiography

  1. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  2. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  3. Image quality in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Gerke, Oke; Thygesen, Jesper

    2018-01-01

    Background Computed tomography (CT) technology is rapidly evolving and software solution developed to optimize image quality and/or lower radiation dose. Purpose To investigate the influence of adaptive statistical iterative reconstruction (ASIR) at different radiation doses in coronary CT...

  4. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Llerena Rojas, Lorenzo D; Mendoza Rodriguez, Vladimir

    2013-01-01

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  5. Intracranial arterial anatomy: evaluation by computed tomography angiography

    International Nuclear Information System (INIS)

    Regattieri, Neysa Aparecida Tinoco; Haetinger, Rainer Guilherme; Liberti, Edson Aparecido

    2010-01-01

    By many decades, the intracranial arteries study was realized exclusively by angiography through selective arterial catheterization. Nowadays, with the technologic evaluation of computerized tomography devices with multi detectors allowing acquisitions with even more thinner slices, higher speed and better resolution, it had appeared a new modality of investigation: the computed tomography angiography, less invasive and with minor morbidity than conventional arteriography. Many studies in the literature have been analyzing the sensibility of the new method for the detection of intracranial aneurysms and comparing them with the conventional arteriography. There is a necessity to recognize the normal intracranial arterial anatomy and its variations using images obtained from multiplanar reformations, in order to give important information for surgeries strategies, such as wall calcifications, aneurismatic neck position and relationships with surrounding anatomical structures. (author)

  6. Computed tomography angiography in patients with active gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Fatima Regina Silva; D' Ippolito, Giuseppe, E-mail: fatima.rsreis@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Cardia, P.P. [Hospital Vera Cruz, Campinas, SP (Brazil)

    2015-11-15

    Gastrointestinal bleeding represents a common medical emergency, with considerable morbidity and mortality rates, and a prompt diagnosis is essential for a better prognosis. In such a context, endoscopy is the main diagnostic tool; however, in cases where the gastrointestinal hemorrhage is massive, the exact bleeding site might go undetected. In addition, a trained professional is not always present to perform the procedure. In an emergency setting, optical colonoscopy presents limitations connected with the absence of bowel preparation, so most of the small bowel cannot be assessed. Scintigraphy cannot accurately demonstrate the anatomic location of the bleeding and is not available at emergency settings. The use of capsule endoscopy is inappropriate in the acute setting, particularly in the emergency department at night, and is a highly expensive method. Digital angiography, despite its high sensitivity, is invasive, presents catheterization-related risks, in addition to its low availability at emergency settings. On the other hand, computed tomography angiography is fast, widely available and minimally invasive, emerging as a promising method in the diagnostic algorithm of these patients, being capable of determining the location and cause of bleeding with high accuracy. Based on a critical literature review and on their own experience, the authors propose a computed tomography angiography protocol to assess the patient with gastrointestinal bleeding. (author)

  7. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  8. Myocardial bridging: evaluation with multislice computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, M.V.L. de; Rabelo, D.R.; Nunes, M.C.P.; Siqueira, M.H.A. [Mater Dei Hospital, Belo Horizonte, MG (Brazil)

    2012-04-15

    Myocardial bridging (MB) is defined as a segment of a major epicardial coronary artery that proceeds intramurally through the myocardium beneath the muscle bridge. Although MB is clinically silent in most cases, it has been associated with myocardial ischemia, myocardial infarction, arrhythmia, and sudden death. Conventional coronary angiography (CCA) is the gold standard for detection, but it is invasive and may not be sensitive enough to detect a thin bridge. Recently, multislice computed tomography coronary angiography (MCTCA) have made possible the clear detection of the entire running courses of coronary arteries and the MB itself. Objective: To evaluate the prevalence MB in patients suspect to coronary artery disease submitted to MCTCA and assessing the predictive value of this method in the midterm. Methods: 498 consecutive patients were examined by MCTCA for the diagnosis of coronary artery disease and followed for a mean follow-up of 17 months for the occurrence of cardiovascular events (death, hospitalization and / or revascularization myocardial). Results: The mean age of patients was 58.4 ± 12.5 years old, 74.3% male. Among the patients, 6,02% (30 patients) showed MB. The major indications were angina pectoris in 45,8% and positive stress testing in 33,3%. 62,5% showed absent atherosclerotic disease and only 1 patient showed moderade descending anterior stenosis. During the follow-up none patient showed hard events. Conclusion: Patients with MB could present with angina pectoris and positive stress testing and showed midterm excellent prognosis. MCTCA is an alternative noninvasive imaging tool that allows for easy and accurate evaluation of MB.

  9. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  10. Sublingual Nitroglycerin Administration in Coronary Computed Tomography Angiography : a Systematic Review

    NARCIS (Netherlands)

    Takx, Richard A. P.; Suchá, D.; Park, Jakob; Leiner, Tim; Hoffmann, Udo

    2015-01-01

    To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography. A systematic

  11. Coronary Computed Tomography Angiography in the Assessment of Acute Chest Pain in the Emergency Room

    Energy Technology Data Exchange (ETDEWEB)

    Prazeres, Carlos Eduardo Elias dos; Cury, Roberto Caldeira; Carneiro, Adriano Camargo de Castro [Hospital do Coração - HCor, Associação do Sanatório Sírio, São Paulo, SP (Brazil); Rochitte, Carlos Eduardo, E-mail: rochitte@cardiol.br [Hospital do Coração - HCor, Associação do Sanatório Sírio, São Paulo, SP (Brazil); Instituto do Coração - InCor - HCFMUSP, São Paulo, SP (Brazil)

    2013-12-15

    The coronary computed tomography angiography has recently emerged as an accurate diagnostic tool in the evaluation of coronary artery disease, providing diagnostic and prognostic data that correlate directly with the data provided by invasive coronary angiography. The association of recent technological developments has allowed improved temporal resolution and better spatial coverage of the cardiac volume with significant reduction in radiation dose, and with the crucial need for more effective protocols of risk stratification of patients with chest pain in the emergency room, recent evaluation of the computed tomography coronary angiography has been performed in the setting of acute chest pain, as about two thirds of invasive coronary angiographies show no significantly obstructive coronary artery disease. In daily practice, without the use of more efficient technologies, such as coronary angiography by computed tomography, safe and efficient stratification of patients with acute chest pain remains a challenge to the medical team in the emergency room. Recently, several studies, including three randomized trials, showed favorable results with the use of this technology in the emergency department for patients with low to intermediate likelihood of coronary artery disease. In this review, we show data resulting from coronary angiography by computed tomography in risk stratification of patients with chest pain in the emergency room, its diagnostic value, prognosis and cost-effectiveness and a critical analysis of recently published multicenter studies.

  12. Coronary Computed Tomography Angiography in the Assessment of Acute Chest Pain in the Emergency Room

    International Nuclear Information System (INIS)

    Prazeres, Carlos Eduardo Elias dos; Cury, Roberto Caldeira; Carneiro, Adriano Camargo de Castro; Rochitte, Carlos Eduardo

    2013-01-01

    The coronary computed tomography angiography has recently emerged as an accurate diagnostic tool in the evaluation of coronary artery disease, providing diagnostic and prognostic data that correlate directly with the data provided by invasive coronary angiography. The association of recent technological developments has allowed improved temporal resolution and better spatial coverage of the cardiac volume with significant reduction in radiation dose, and with the crucial need for more effective protocols of risk stratification of patients with chest pain in the emergency room, recent evaluation of the computed tomography coronary angiography has been performed in the setting of acute chest pain, as about two thirds of invasive coronary angiographies show no significantly obstructive coronary artery disease. In daily practice, without the use of more efficient technologies, such as coronary angiography by computed tomography, safe and efficient stratification of patients with acute chest pain remains a challenge to the medical team in the emergency room. Recently, several studies, including three randomized trials, showed favorable results with the use of this technology in the emergency department for patients with low to intermediate likelihood of coronary artery disease. In this review, we show data resulting from coronary angiography by computed tomography in risk stratification of patients with chest pain in the emergency room, its diagnostic value, prognosis and cost-effectiveness and a critical analysis of recently published multicenter studies

  13. Coronary Computed Tomography Angiography Derived Fractional Flow Reserve and Plaque Stress

    DEFF Research Database (Denmark)

    Nørgaard, Bjarne Linde; Leipsic, Jonathon; Koo, Bon-Kwon

    2016-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is an independent prognosticator in patients with coronary artery disease and the gold standard for decision making in coronary revascularization. The integration of computational fluid dynamics and quantitative anatomic...... and physiologic modeling now enables simulation of patient-specific hemodynamic parameters including blood velocity, pressure, pressure gradients, and FFR from standard acquired coronary computed tomography (CT) datasets. In this review article, we describe the potential impact on clinical practice...... and the science behind noninvasive coronary computed tomography (CT) angiography derived fractional flow reserve (FFRCT) as well as future applications of this technology in treatment planning and quantifying forces on atherosclerotic plaques....

  14. The value of standard radiology, angiography and computed tomography for the diagnosis of primary and secondary bone tumors

    International Nuclear Information System (INIS)

    Wagner, R.

    1986-01-01

    The diagnostic value of X-ray images, angiography and computed tomography (CT) was compared using 45 benign, semi-malignant and malignant bone tumors. All around, computed tomography proved to be more accurate than angiography. CT is therefore recommended for use as the first non-invasive examination method after X-ray images have been made. (MBC) [de

  15. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    Energy Technology Data Exchange (ETDEWEB)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients.

  16. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    International Nuclear Information System (INIS)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients

  17. Evaluation of patient dose during computed tomography angiography

    International Nuclear Information System (INIS)

    Dafalla, Elamam Yagoob Taha

    2015-10-01

    Computed tomography (CT), is an x-ray procedure that generates high quality cross sectional images of the body, and by comparison to other radiological diagnosis, CT is responsible for higher doses to patients. The evaluation of patient dose from computed tomography for pulmonary examinations the CT is responsible for higher doses to patients. The radiation dose was measured in three hospitals in Khartoum State during March 2015-October 2015 using different CT modalities. The radiation dose was higher at Alzytouna hospital than Daralelaj hospital and Alatebaa hospital was lowest. In this study, the mean effective dose for first hospital was 23.83±3.93 mSv and the mean effective dose for second hospital was 8.94±1.64 mSv and the mean effective dose for third hospital was 2.96±0.79. (author)

  18. Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Uren Neal G

    2007-06-01

    Full Text Available Abstract Background Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. Methods Fifty patients with previous coronary artery bypass surgery who were listed for diagnostic coronary angiography underwent contrast enhanced computed tomography angiography using a 16-slice computed tomography scanner. Images were retrospectively gated to the electrocardiogram and two dimensional axial, multiplanar and three dimensional reconstructions acquired. Sensitivity, specificity, positive and negative predictive value, accuracy and level of agreement for detection of graft patency by multidetector computed tomography. Results A total of 116 grafts were suitable for analysis. The specificity of CT for the detection of graft patency was 100%, with a sensitivity of 92.8%, positive predictive value 100%, negative predictive value 85.8% and an accuracy of 94.8%. The kappa value of agreement between the two means of measuring graft patency was 0.9. Mean radiation dose was 9.0 ± 7.2 mSv for coronary angiography and 18.5 ± 4 mSv for computed tomography. Pooled analysis of eight studies, incorporating 932 grafts, confirmed a 97% accuracy for the detection of graft patency by multidetector computed tomography. Conclusion Computed tomography is an accurate, rapid and non-invasive method of assessing coronary artery bypass graft patency. However, this was achieved at the expense of an increase in radiation dose.

  19. Congenital Absence of Left Circumflex Artery Detected by Computed Tomography Coronary Angiography: A Case Report

    Directory of Open Access Journals (Sweden)

    Keerati Hongsakul

    2012-01-01

    Full Text Available The congenital absence of the left circumflex artery (LCx is a very rare congenital anomaly of coronary arteries, but it is benign. Currently, the best modality for the diagnosis of coronary anomalies is computed tomography coronary angiography (CTCA. We report a case of congenitally absent LCx with an atypical chest pain.

  20. Clinical application of electron beam computed tomography in intravenous three-dimensional coronary angiography

    International Nuclear Information System (INIS)

    Luo Chufan; Du Zhimin; Hu Chengheng; Li Yi; Zeng Wutao; Ma Hong; Li Xiangmin; Zhou Xuhui

    2002-01-01

    Objective: To investigate the clinical application of intravenous three-dimensional coronary angiography using electron beam computed tomography (EBCT) as compared with selective coronary angiography. Methods: Intravenous EBCT and selective coronary angiography were performed during the same period in 38 patients. The value of EBCT angiography for diagnosing coronary artery disease was evaluated. Results: The number of coronary arteries adequately evaluated by EBCT angiography was 134 out of 152 vessels (88.2%), including 100% of the left main coronary arteries, 94.7% of the left anterior descending arteries, 81.6% of the left circumflex arteries and 76.3 % of the right coronary arteries. Significantly more left main and heft anterior descending coronary arteries were adequately visualized than the left circumflex and right coronary arteries (P < 0.05). The sensitivity, specificity, accuracy, and positive and negative predictive value of EBCT angiography for diagnosing coronary artery disease were 88.0%, 84.6%, 86.8%, 91.7% and 78.6%, respectively. Of the 38 arteries with ≥ 50% stenosis, EBCT underestimated 8, for a sensitivity of 78.9%. Of the 96 arteries without significant stenosis, EBCT overestimated 7 stenosis, for a specificity of 92.7%. Conclusion: Intravenous electron beam computed tomographic coronary angiography is a promising noninvasive method for diagnosing coronary artery disease

  1. Fractional Flow Reserve Measurement by Coronary Computed Tomography Angiography: A Review with Future Directions

    Directory of Open Access Journals (Sweden)

    Asim Rizvi

    2016-12-01

    Full Text Available Invasive fractional flow reserve (FFR measurement is currently the gold standard for coronary intervention. FFR measurement by coronary computed tomography angiography (FFRCT is a novel and promising imaging technology that permits noninvasive assessment of physiologically significant coronary lesions. FFRCT is capable of combining the anatomic information provided by coronary computed tomography angiography with computational fluid dynamics to compute FFR. To date, several studies have reported the diagnostic performance of FFRCT compared with invasive FFR measurement as the reference standard. Further studies are now being implemented to determine the clinical feasibility and economic implications of FFRCT techniques. This article provides an overview and discusses the available evidence as well as potential future directions of FFRCT.

  2. Imaging of peripheral arteries by 16-slice computed tomography angiography: a valuable tool

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2007-01-01

    To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral vascular disease. Thirty three patients underwent multislice computed tomography angiography (MSCTA) of the upper or the lower limb on multislice (16-slice) CT scanner between November 2004 and July 2005 in the Department of Radiology, National Organ Transplant Center, Tripoli, Libya. The findings were retrospectively compared with the surgical outcome in cases of trauma with suspected arterial injuries; or color Doppler correlation was obtained, for patients of peripheral vascular disease. Multislice computed tomography angiography allows a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In 23 cases of peripheral vascular diseases, MSCTA adequately demonstrated the presence of any stenosis or occlusion, its degree and extent, the presence of collaterals and distal reformation if any; the presence of plaques. Our experience of computed tomography angiography with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries; and as a useful screening modality in cases of peripheral vascular disease for diagnosis and for grading. (author)

  3. The Role of Coronary Computed Tomography Angiography and Cardiac Magnetic Resonance in STEMI Patients with Normal Coronary Angiography

    Directory of Open Access Journals (Sweden)

    Beganu Elena

    2017-09-01

    Full Text Available Usually, the diagnosis of myocardial infarction based on patient symptoms, electrocardiogram (ECG changes, and cardiac enzymes, is not a challenge for cardiologists. The correlation between coronary anatomy and the ECG territories that present ischemic changes can help the clinician to estimate which coronary artery presents lesions upon performing a coronary angiogram. In certain situations, the diagnosis of myocardial infarction can be difficult due to the lack of correlations between the clinical and paraclinical examinations and the coronary angiogram. In some cases, patients with chest pain and ST-segment elevation on the ECG tracing present with a normal coronary angiography. In other cases, patients without important changes on the ECG can present critical lesions or even occlusions upon angiographic examination. The aim of this article is to highlight the role of noninvasive coronary magnetic resonance and multi-slice computed tomography in patients with ST-segment elevation myocardial infarction and normal coronary angiography.

  4. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  5. Computed tomography angiography in acute stroke (revisiting the 4Ps of imaging).

    Science.gov (United States)

    Varadharajan, Shriram; Saini, Jitender; Acharya, Ullas V; Gupta, Arun Kumar

    2016-02-01

    Imaging in acute stroke has traditionally focussed on the 4Ps-parenchyma, pipes, perfusion, and penumbra-and has increasingly relied upon advanced techniques including magnetic resonance imaging to evaluate such patients. However, as per European Magnetic Resonance Forum estimates, the availability of magnetic resonance imaging scanners for the general population in India (0.5 per million inhabitants) is quite low as compared to Europe (11 per million) and United States (35 per million), with most of them only present in urban cities. On the other hand, computed tomography (CT) is more widely available and has reduced scanning duration. Computed tomography angiography of cervical and intracranial vessels is relatively simpler to perform with extended coverage and can provide all pertinent information required in such patients. This imaging review will discuss relevant imaging findings on CT angiography in patients with acute ischemic stroke through illustrated cases. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H.; Broersen, Alexander

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model- based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) im- ages on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods...

  7. Apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.

    Directory of Open Access Journals (Sweden)

    Ioannis Pneumatikos

    2008-10-01

    Full Text Available Respiratory motion artifact in intubated and mechanically ventilated patients often reduces the quality of helical computed tomography pulmonary angiography (CTPA. Apneic oxygenation is a well established intra-operative technique that allows adequate oxygenation for short periods (up to 10 min in sedated and paralyzed patients. We describe the use of the apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.

  8. Prevalence and Characteristics of Myocardial Bridging in Multidetector-Row Computed Tomography Coronary Angiography

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Martin Lopez, Elba; Capunay, Carlos; Deviggiano, Alejandro; Vallejos, Javier; Carrascosa, Jorge

    2009-01-01

    Background: Myocardial bridging (MB) are congenital defects of the coronary arteries in which a segment of an epicardial artery lies in the myocardium for part of its course. The current gold standard for diagnosing MB is coronary angiography; however other invasive techniques are also useful. Myocardial bridging can also be visualized with the use of novel non-invasive imaging techniques such as multidetector-row computed tomography coronary angiography (MDCT-CA). Objectives: To assess the prevalence and characteristics of myocardial bridging in patients undergoing multidetector-row computed tomography coronary angiography (MDCT-CA). Material and Methods: A total of 452 consecutive patients were evaluated with 16-row and 64-row MDCT-CA due to the presence of abnormal findings in myocardial perfusion image tests, symptoms suggestive of coronary artery disease, and in asymptomatic patients with a family history of coronary artery disease. The presence of MB, their location and characteristics were analyzed. Myocardial bridging were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of the artery involved. Quantitative measurements of vessel diameter during systole and diastole were evaluated. Results: The prevalence of MB was 35.18%; 88 were complete and 71 incomplete. Among complete MB, 6 affected both systole and diastole, 27 presented only systolic compression and 55 showed no compression. Incomplete MB showed absence of arterial compression. Conclusions: Multidetector-row computed tomography coronary angiography detected a higher prevalence of MB in the study population and allowed to classify them and to assess their functional aspects throughout the cardiac cycle. (authors) [es

  9. Early-Dynamic Positron Emission Tomography (PET)/Computed Tomography and PET Angiography for Endoleak Detection After Endovascular Aneurysm Repair.

    Science.gov (United States)

    Drescher, Robert; Gühne, Falk; Freesmeyer, Martin

    2017-06-01

    To propose a positron emission tomography (PET)/computed tomography (CT) protocol including early-dynamic and late-phase acquisitions to evaluate graft patency and aneurysm diameter, detect endoleaks, and rule out graft or vessel wall inflammation after endovascular aneurysm repair (EVAR) in one examination without intravenous contrast medium. Early-dynamic PET/CT of the endovascular prosthesis is performed for 180 seconds immediately after intravenous injection of F-18-fluorodeoxyglucose. Data are reconstructed in variable time frames (time periods after tracer injection) to visualize the arterial anatomy and are displayed as PET angiography or fused with CT images. Images are evaluated in view of vascular abnormalities, graft configuration, and tracer accumulation in the aneurysm sac. Whole-body PET/CT is performed 90 to 120 minutes after tracer injection. This protocol for early-dynamic PET/CT and PET angiography has the potential to evaluate vascular diseases, including the diagnosis of complications after endovascular procedures.

  10. Diagnostic accuracy of coronary angiography with multislice computed tomography applied to 'the Real World'

    International Nuclear Information System (INIS)

    Rodriguez Granillo, Gaston A.; Rosales, Miguel A.; Llaurado, Claudio; Fernandez Pereira, Carlos; Garcia Carcia, Hector M.

    2006-01-01

    Objective: To assess the diagnostic accuracy of Coronary Angiography with Multislice Computed Tomography (MSCT) for the detection of significant coronary artery stenoses. Material and methods: Patients studied had an indication for diagnostic coronary angiography and no history of contrast allergies, renal failure or arrhythmias. A multislice tomography equipment (Brilliance 40, Philips, The Netherlands) with ECG gating was used for image acquisition. A total of 90-125 mI of iodinated contrast was administered by IV route. Obesity, diabetes, diffusely calcified segments with a diameter < 2.0 mm, and segments treated with stents were not considered exclusion criteria. Lesions were defined as significant when the decrease in Iumen was ≥ 50% by MSCT and quantitative coronary angiography (QCA). Results: A total of 38 patients were scanned before the intervention. Of them, one (3%) was excluded because of inadequate image quality. The remaining 37 patients (444 segments), with an adequate quality image, were included in the study (81% men, mean age 62.43 ± 12.5 years, 13.5% diabetics). Mean scan time was 15.12 ± 2.6 seconds, and 444 segments were assessed with both techniques. The number of lesions deemed significant by QCA and MSCT were 88 (17%) and 93 (18%), respectively. Sensitivity, specificity, positive and negative predictive values of MSCT to detect significant stenoses were 82%, 93%, 72% and 96%, respectively. Conclusion: In non-selected patients, coronary angiography by multislice computed tomography exhibits a high negative predictive value for the detection of obstructive coronary disease. (author)

  11. Utility of computed axial tomography angiography in anatomic evaluation of pediatric patients with congenital heart diseases

    International Nuclear Information System (INIS)

    Mosquera, Walter A; Reyes P, Rafael; Aguilera N, Favio M; Breton, Cesar A; Buitrago, Danuby A; Suarez J Ramiro; Castillo, Victor

    2007-01-01

    Although echocardiogram and cardiac catheterization are used as first option tools for congenital heart diseases diagnosis, computed tomography angiography is a minimally invasive exam that through two to three dimensional images in real time gives an adequate approach to patients having this type of pathologies that require a rapid and precise evaluation of its extra cardiac anatomy. Objective: describe the institutional experience from August 2005 to August 2006 in the use of angiography by tomography as a complementary diagnostic method in the evaluation of pediatric patients with congenital heart diseases. Method: serial descriptive study. 58 pediatric patients with clinical and echocardiographic diagnosis of congenital heart diseases were evaluated through the General Electric Multislice Light peed/16 scanner. Results: 58 patients with history of congenital heart disease were evaluated through CT angiography. Mean age was 2.4 ± 4.03 years. Twenty (33.8%) had diagnosis of pulmonary atresia, four (6.7%) had tricuspid atresia, eight (13.5%,) had double-outlet right ventricle, seven (11.8%) had tetralogy of Fallot, nine (15.2%) had alterations of the aortic arch, seven (11.8%) had coarctation of the aorta two (3.3%) had interrupted aortic arch, six (10.3%) had persistent ductus arteriosus, four (6.7%) had anomalous venous drainage and three (5.1 %) had transposition of the great arteries. High quality images that allowed assessing the precise vascular anatomy were obtained. Conclusions: computed tomography angiography turned out to be a useful tool in the diagnostic approach of congenital heart diseases, because it allowed a tridimensional anatomic reconstruction. New studies that may permit the assessment of sensitivity, specificity and concordance level of this technique with other invasive diagnostic methods available for the diagnosis of this type of diseases, are required

  12. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G. (Dept. of Radiology, Dept. of Vascular Diagnosis and Research, and Division of Cardiology, Aker Univ. Hospital, Oslo (Norway))

    2008-12-15

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome.

  13. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G.

    2008-01-01

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome

  14. Free and open-source software application for the evaluation of coronary computed tomography angiography images.

    Science.gov (United States)

    Hadlich, Marcelo Souza; Oliveira, Gláucia Maria Moraes; Feijóo, Raúl A; Azevedo, Clerio F; Tura, Bernardo Rangel; Ziemer, Paulo Gustavo Portela; Blanco, Pablo Javier; Pina, Gustavo; Meira, Márcio; Souza e Silva, Nelson Albuquerque de

    2012-10-01

    The standardization of images used in Medicine in 1993 was performed using the DICOM (Digital Imaging and Communications in Medicine) standard. Several tests use this standard and it is increasingly necessary to design software applications capable of handling this type of image; however, these software applications are not usually free and open-source, and this fact hinders their adjustment to most diverse interests. To develop and validate a free and open-source software application capable of handling DICOM coronary computed tomography angiography images. We developed and tested the ImageLab software in the evaluation of 100 tests randomly selected from a database. We carried out 600 tests divided between two observers using ImageLab and another software sold with Philips Brilliance computed tomography appliances in the evaluation of coronary lesions and plaques around the left main coronary artery (LMCA) and the anterior descending artery (ADA). To evaluate intraobserver, interobserver and intersoftware agreements, we used simple and kappa statistics agreements. The agreements observed between software applications were generally classified as substantial or almost perfect in most comparisons. The ImageLab software agreed with the Philips software in the evaluation of coronary computed tomography angiography tests, especially in patients without lesions, with lesions 70% in the ADA was lower, but this is also observed when the anatomical reference standard is used.

  15. Scimitar syndrome: multi detector computed tomography angiography findings of a case

    International Nuclear Information System (INIS)

    Aslan, A.; Bozlar, U.; Ors, F.; Tasar, M.

    2012-01-01

    Full text: Introduction: Scimitar syndrome also known as pulmonary venolobar syndrome is a rare congenital abnormality. This abnormality consists of ipsilateral anomalous pulmonary venous drainage of right lung into the inferior vena cava (IVC), with hypoplasia of the right lung, an anomalous systemic arterial supply from supradiaphragmatic aorta to the right lower lobe and dextrocardia. Objectives and tasks: In this article, we aimed to present multidetector computed tomography (MDCT) angiography findings of a case with scimitar syndrome. Material and methods: 21 year old male with dextrocardia and anomalous curvilinear density in the right lower lobe directed toward the right hemidiaphragm on chest radiography was evaluated with MDCT angiography examination. Results: Dextrocardia and interruption of IVC with azygous continuation was detected in MDCT angiography examination. Vertically directing right superior pulmonary vein was draining to the suprahepatic segment of IVC. Pulmonary sequestration in the right lower lobe taking feeder from celiac trunk was detected. Right pulmonary artery was hypoplastic and bronchial tree was abnormal, manifesting as a mirror image in both lung lobes. Conclusion: MDCT angiography is very successful imaging method in demonstrating the anomalous pulmonary vein and assessing pulmonary arterial and bronchial anomalies

  16. The Basilar Artery on Computed Tomography Angiography Prognostic Score for Basilar Artery Occlusion.

    Science.gov (United States)

    Alemseged, Fana; Shah, Darshan G; Diomedi, Marina; Sallustio, Fabrizio; Bivard, Andrew; Sharma, Gagan; Mitchell, Peter J; Dowling, Richard J; Bush, Steven; Yan, Bernard; Caltagirone, Carlo; Floris, Roberto; Parsons, Mark W; Levi, Christopher R; Davis, Stephen M; Campbell, Bruce C V

    2017-03-01

    Basilar artery occlusion is associated with high risk of disability and mortality. This study aimed to assess the prognostic value of a new radiological score: the Basilar Artery on Computed Tomography Angiography (BATMAN) score. A retrospective analysis of consecutive stroke patients with basilar artery occlusion diagnosed on computed tomographic angiography was performed. BATMAN score is a 10-point computed tomographic angiography-based grading system which incorporates thrombus burden and the presence of collaterals. Reliability was assessed with intraclass coefficient correlation. Good outcome was defined as modified Rankin Scale score of ≤3 at 3 months and successful reperfusion as thrombolysis in cerebral infarction 2b-3. BATMAN score was externally validated and compared with the Posterior Circulation Collateral score. The derivation cohort included 83 patients with 41 in the validation cohort. In receiver operating characteristic (ROC) analysis, BATMAN score had an area under receiver operating characteristic curve of 0.81 (95% confidence interval [CI], 0.7-0.9) in derivation cohort and an area under receiver operating characteristic curve of 0.74 (95% CI, 0.6-0.9) in validation cohort. In logistic regression adjusted for age and clinical severity, BATMAN score of BATMAN score of BATMAN score had greater accuracy compared with Posterior Circulation Collateral score ( P =0.04). The addition of collateral quality to clot burden in BATMAN score seems to improve prognostic accuracy in basilar artery occlusion patients. © 2017 American Heart Association, Inc.

  17. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Directory of Open Access Journals (Sweden)

    Carlos Fernando de Mello Júnior

    2016-06-01

    Full Text Available Abstract Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  18. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Energy Technology Data Exchange (ETDEWEB)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil); Reboucas, Rafael Batista, E-mail: severinoaires@hotmail.com [Faculdade de Ciencias Medicas da Paraiba, Joao Pessoa, PB (Brazil)

    2016-05-15

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  19. Gender differences in coronary plaque composition by coronary computed tomography angiography.

    Science.gov (United States)

    Blaha, Michael J; Nasir, Khurram; Rivera, Juan J; Choi, Eue-Keun; Chang, Sung-A; Yoon, Yeonyee E; Chun, Eun Ju; Choi, Sang-il; Agatston, Arthur; Blumenthal, Roger S; Chang, Hyuk-Jae

    2009-12-01

    Coronary computed tomography angiography allows the differentiation of non-calcified (NCAP), calcified (CAP), and mixed coronary artery plaques (MCAP). Although males are thought to have a higher prevalence of atherosclerosis for a given age, there are currently few data regarding age-adjusted sex differences in plaque morphology and composition. We studied 1015 consecutive asymptomatic South Korean patients (49+/-10 years, 64% men) who underwent 64-slice coronary computed tomography angiography during a routine health evaluation. Coronary plaque characteristics were analyzed on a per-segment basis according to the modified AHA classification. Plaques with more than 50% calcified tissue were classified as CAP, plaques with less than 50% calcified tissue were classified as MCAP, and plaques without calcium were classified as NCAP. Multiple regression analysis was used to describe the cross-sectional association between sex and plaque-type burden (>or=2 affected segments) after adjustment for age and other cardiovascular risk factors. There was a greater prevalence of coronary plaque among men (13 vs. 4%, PNCAP was similar across sex (2 vs. 1%, P = 0.28). After multivariable adjustment, men have six to seven times greater odds of having an increased burden of CAP and MCAP, whereas no sex difference was observed in the burden of NCAP. In this population of asymptomatic middle-aged Korean individuals, males had a significantly greater burden of MCAP and CAP. Future studies will determine whether these differences contribute to the accelerated cardiovascular risk observed in men.

  20. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    International Nuclear Information System (INIS)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de; Reboucas, Rafael Batista

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  1. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  2. Coronary plaque quantification and fractional flow reserve by coronary computed tomography angiography identify ischaemia-causing lesions

    DEFF Research Database (Denmark)

    Gaur, Sara; Øvrehus, Kristian Altern; Dey, Damini

    2016-01-01

    AIMS: Coronary plaque characteristics are associated with ischaemia. Differences in plaque volumes and composition may explain the discordance between coronary stenosis severity and ischaemia. We evaluated the association between coronary stenosis severity, plaque characteristics, coronary computed...... tomography angiography (CTA)-derived fractional flow reserve (FFRCT), and lesion-specific ischaemia identified by FFR in a substudy of the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). METHODS AND RESULTS: Coronary CTA stenosis, plaque volumes, FFRCT, and FFR were assessed...

  3. CT angiography using electron-beam computed tomography (EBCT). A phantom study

    International Nuclear Information System (INIS)

    Uchino, Akira; Kato, Akira; Kudo, Sho

    1997-01-01

    The purpose of this study was to evaluate the accuracy of CT angiography in small vessels using electron-beam computed tomography (EBCT). Vessel phantoms with inner diameters of 8 mm, 6 mm, and 4 mm were prepared with segments of 75%, 50%, and 25% stenosis in each vessel. The vessels were filled with contrast medium (Iopamidol 300 at 1/24 dilution, approximately 380 HU). The EBCT apparatus used was an Imatron C-150. The step volume scan mode was used with slice thicknesses of 1.5 mm and 3.0 mm, scan time of 0.3 sec, and 210 mm field of view. Images with a slice thickness of 1.5 mm were definitely better than those with a slice thickness of 3.0 mm. The quality of maximum intensity projection (MIP) images was quite similar to that of three-dimensional (3D) images. Using the 8 mm vessel phantom, all stenotic segments were accurately visualized on CT angiography. The 50% stenotic segments were accurately estimated in all vessels. However, the 75% stenotic segments were slightly overestimated in smaller vessels, and the 25% stenotic segments were slightly underestimated in smaller vessels. We consider CT angiography using EBCT to be a useful, less invasive diagnostic modality for stenoocclusive lesions. (author)

  4. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  5. Malignant hemangiopericytoma. A correlative study of angiography, computed tomography, and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Kuroda, Yasumasa; Kobashi, Yoichiro; Ichijima, Kunio; Odori, Teruo; Torizuka, Kanji [Kyoto Univ. (Japan). Hospital

    1983-01-01

    Four cases of primary and secondary malignant hemangiopericytoma were correlatively studied using selective angiography, computed tomography, and pathologic specimens. One case was found in each of the peritoneal space (metastasis), the left middle cranial fossa, the left thigh, and the left retroperitoneal space. Basic angiographic features of the tumor were a few feeding arteries entering the tumor with radially arranged fine network throughout, early visualization of veins due to A-V shunting, and a long-standing tumor stain with avascular area (s). Correlative evaluation of angiograms, computed tomograms, and pathologic specimens revealed hemorrhage, central necrosis, and cystic degeneration for the avascular area (s) of the tumor stains on the angiograms. The more prominent those secondary changes, the less characteristic the angiographic features.

  6. Novel Approaches for the Use of Cardiac/Coronary Computed Tomography Angiography

    Directory of Open Access Journals (Sweden)

    Hadi Mirhedayati Roudsari, MD

    2016-12-01

    Full Text Available Recent developments in the novel imaging technology of cardiac computed tomography (CT not only permit detailed assessment of cardiac anatomy but also provide insight into cardiovascular physiology. Foremost, coronary CT angiography (CCTA enables direct noninvasive examination of both coronary artery stenoses and atherosclerotic plaque characteristics. Calculation of computational fluid dynamics by cardiac CT allows the noninvasive estimation of fractional flow reserve, which increases the diagnostic accuracy for detection of hemodynamically significant coronary artery disease. In addition, a combination of myocardial CT perfusion and CCTA can provide simultaneous anatomical and functional assessment of coronary artery disease. Finally, detailed anatomical evaluation of atrial, ventricular, and valvular anatomy provides diagnostic information and guidance for procedural planning, such as for transcatheter aortic valve replacement. The clinical applications of cardiac CT will be extended with the development of these novel modalities.

  7. Assessment of radiation exposure on a dual-source computed tomography-scanner performing coronary computed tomography-angiography

    International Nuclear Information System (INIS)

    Kirchhoff, S.; Herzog, P.; Johnson, T.; Boehm, H.; Nikolaou, K.; Reiser, M.F.; Becker, C.H.

    2010-01-01

    Objective: The radiation exposure of a dual-source-64-channel multi-detector-computed-tomography-scanner (Somatom-Defintion, Siemens, Germany) was assessed in a phantom-study performing coronary-CT-angiography (CTCA) in comparison to patients' data randomly selected from routine scanning. Methods: 240 CT-acquisitions of a computed tomography dose index (CTDI)-phantom (PTW, Freiburg, Germany) were performed using a synthetically generated Electrocardiography (ECG)-signal with variable heart rates (30-180 beats per minute (bpm)). 120 measurements were acquired using continuous tube-output; 120 measurements were performed using ECG-synchronized tube-modulation. The pulsing window was set at minimum duration at 65% of the cardiac cycle between 30 and 75 bpm. From 90-180 bpm the pulsing window was set at 30-70% of the cardiac cycle. Automated pitch adaptation was always used. A comparison between phantom CTDI and two patient groups' CTDI corresponding to the two pulsing groups was performed. Results: Without ECG-tube-modulation CDTI-values were affected by heart-rate-changes resulting in 85.7 mGray (mGy) at 30 and 45 bpm, 65.5 mGy/60 bpm, 54.7 mGy/75 bpm, 46.5 mGy/90 bpm, 34.2 mGy/120 bpm, 27.0 mGy/150 bpm and 22.1 mGy/180 bpm equal to effective doses between 14.5 mSievert (mSv) at 30/45 bpm and 3.6 mSv at 180 bpm. Using ECG-tube-modulation these CTDI-values resulted: 32.6 mGy/30 bpm, 36.6 mGy/45 bpm, 31.4 mGy/60 bpm, 26.8 mGy/75 bpm, 23.7 mGy/90 bpm, 19.4 mGy/120 bpm, 17.2 mGy/150 bpm and 15.6 mGy/180 bpm equal to effective doses between 5.5 mSv at 30 bpm and 2.6 mSv at 180 bpm. Significant CTDI-differences were found between patients with lower/moderate and higher heart rates in comparison to the phantom CTDI-results. Conclusions: Dual source CTCA is particularly dose efficient at high heart rates when automated pitch adaptation, especially in combination with ECG-based tube-modulation is used. However in clinical routine scanning for patients with higher heart rates

  8. Identification of discrete vascular lesions in the extremities using post-mortem computed tomography angiography – Case reports

    NARCIS (Netherlands)

    Haakma, Wieke; Rohde, Marianne; Uhrenholt, Lars; Pedersen, Michael; Boel, Lene Warner Thorup

    2017-01-01

    In this case report, we introduced post-mortem computed tomography angiography (PMCTA) in three cases suffering from vascular lesions in the upper extremities. In each subject, the third part of the axillary arteries and veins were used to catheterize the arms. The vessels were filled with a barium

  9. Post-mortem computed tomography angiography utilizing barium sulfate to identify microvascular structures : a preliminary phantom model and case study

    NARCIS (Netherlands)

    Haakma, Wieke; Rohde, Marianne; Kuster, Lidy; Uhrenholt, Lars; Pedersen, Michael; Boel, Lene Warner Thorup

    2016-01-01

    We investigated the use of computer tomography angiography (CTA) to visualize microvascular structures in a vessel-mimicking phantom and post-mortem (PM) bodies. A contrast agent was used based on 22% barium sulfate, 20% polyethylene glycol and 58% distilled water. A vessel-mimicking phantom

  10. Value of Myocardial Perfusion Assessment With Coronary Computed Tomography Angiography in Patients With Recent Acute-Onset Chest Pain

    DEFF Research Database (Denmark)

    Sørgaard, Mathias H; Linde, Jesper J; Kühl, J Tobias

    2018-01-01

    was the frequency of coronary revascularization among patients referred for invasive coronary angiography (ICA) based on index computed tomography evaluation. Secondary endpoints were invasive procedural complications at index-related ICA, post-index cardiac death, hospital admittance because of recurrence of chest...

  11. Non-obstructive coronary artery disease assessed by coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nielsen, L.; Bøtker, H. E.; Sorensen, H.

    2015-01-01

    Introduction: Coronary CT angiography (CTA) detects non-obstructive coronary artery disease (CAD) that may not be recognized by functional testing, but the prognostic impact is not well understood. This study aimed to compare the risk of myocardial infarction (MI) and all-cause mortality...... in patients without or with non-obstructive and obstructive CAD assessed by coronary CTA. Methods: Consecutive patients without known coronary artery disease (CAD) and with chest pain who underwent coronary CTA (>64-detector row) between January 2007 and December 2012 in the 10 centers participating...... in the Western Denmark Cardiac Computed Tomography Registry were included. The endpoints were 3-year MI or all-cause mortality. The coronary CTA result was defined as normal (0% luminal stenosis), non-obstructive CAD (1%-49% luminal stenosis) or obstructive CAD (>50% luminal stenosis; 1-vessel, 2-vessel, or 3...

  12. Prognostic assessment of stable coronary artery disease as determined by coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Hüche Nielsen, Lene; Bøtker, Hans Erik; Sørensen, Henrik T.

    2017-01-01

    Aims: To examine the 3.5 year prognosis of stable coronary artery disease (CAD) as assessed by coronary computed tomography angiography (CCTA) in real-world clinical practice, overall and within subgroups of patients according to age, sex, and comorbidity. Methods and results: This cohort study......, and comorbidity. Conclusion: Coronary artery disease determined by CCTA in real-world practice predicts the 3.5 year composite risk of late revascularization, myocardial infarction, and all-cause death across different groups of age, sex, or comorbidity burden....... included 16,949 patients (median age 57 years; 57% women) with new-onset symptoms suggestive of CAD, who underwent CCTA between January 2008 and December 2012. The endpoint was a composite of late coronary revascularization procedure >90 days after CCTA, myocardial infarction, and all-cause death...

  13. Effects of Hyperthyroidism on Coronary Artery Disease: A Computed Tomography Angiography Study.

    Science.gov (United States)

    Beyer, Christoph; Plank, Fabian; Friedrich, Guy; Wildauer, Matthias; Feuchtner, Gudrun

    2017-10-01

    Changes in thyroid hormone concentration can negatively affect the cardiovascular system. Subclinical hyperthyroidism has been linked to an increase of cardiovascular heart disease, however, clinical effects and significance are still uncertain. Therefore, we analyzed coronary computed tomography angiographies of patients with overt and subclinical hyperthyroidism for quantitative parameters and plaque morphology. Seven hundred forty-four (47.1% female) patients who underwent coronary computed tomography angiography were stratified into 3 groups: 51 patients with overt, 74 patients with subclinical hyperthyroidism, and 619 patients with euthyroidism. Analysis included grades of stenosis (no stenosis = 0, mild 70%) and plaque types (noncalcified, mixed, and calcified), segment involvement score (SIS), noncalcified SIS, and high-risk plaque features (napkin ring sign, low attenuation plaque, spotty calcifications, positive remodelling). Patients with overt and subclinical hyperthyroidism had more high-grade stenoses (39.2% vs 37.8% vs 24.2%; P = 0.007) and a higher coronary calcium score (456.5 vs 199.5 vs 155.9; P hyperthyroidism, followed by those with subclinical hyperthyroidism, had the most high-risk plaque features: napkin ring (21.6% vs 9.5% vs 6.0%, P hyperthyroid patients. Patients with subclinical and overt hyperthyroidism showed more high-grade coronary stenoses, plaque burden, and high-risk plaque features than patients with euthyroidism, which indicates that an increase of thyroid hormones might lead to coronary vascular degeneration and plaque instability. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. The New Frontier of Cardiac Computed Tomography Angiography: Fractional Flow Reserve and Stress Myocardial Perfusion.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Mushtaq, Saima; Baggiano, Andrea; Conte, Edoardo; Beltrama, Virginia; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Rabbat, Mark G; Pepi, Mauro

    2016-12-01

    The increased number of patients with coronary artery disease (CAD) in developed countries is of great clinical relevance and involves a large burden of the healthcare system. The management of these patients is focused on relieving symptoms and improving clinical outcomes. Therefore the ideal test would provide the correct diagnosis and actionable information. To this aim, several non-invasive functional imaging modalities are usually used as gatekeeper to invasive coronary angiography (ICA), but their diagnostic yield remains low with limited accuracy when compared to obstructive CAD at the time of ICA or invasive fractional flow reserve (FFR). Invasive FFR is considered the gold standard for the evaluation of functionally relevant CAD. Therefore, an urgent need for non-invasive techniques that evaluate both the functional and morphological severity of CAD is growing. Coronary computed tomography angiography (CCTA) has emerged as a unique non-invasive technique providing coronary artery anatomic imaging. More recently, the evaluation of FFR with CCTA (FFR CT ) has demonstrated high diagnostic performance compared to invasive FFR. Additionally, stress myocardial computed tomography perfusion (CTP) represents a novel tool for the diagnosis of ischemia with high diagnostic accuracy. Compared to nuclear imaging and cardiac magnetic resonance imaging, both FFR CT and stress-CTP, allow us to integrate the anatomical evaluation of coronary arteries with the functional relevance of coronary artery lesions having the potential to revolutionize the diagnostic paradigm of suspected CAD. FFR CT and stress-CTP could be assimilated in diagnostic pathways of patients with stable CAD and will likely result in a decrease of invasive diagnostic procedures and costs. The current review evaluates the technical aspects and clinical experience of FFR CT and stress-CTP in the evaluation of functionally relevant CAD discussing the strengths and weaknesses of each approach.

  15. Non-invasive coronary angiography with multislice computed tomography. Technology, methods, preliminary experience and prospects.

    Science.gov (United States)

    Traversi, Egidio; Bertoli, Giuseppe; Barazzoni, Giancarlo; Baldi, Maurizia; Tramarin, Roberto

    2004-02-01

    The recent technical developments in multislice computed tomography (MSCT), with ECG retro-gated image reconstruction, have elicited great interest in the possibility of accurate non-invasive imaging of the coronary arteries. The latest generation of MSCT systems with 8-16 rows of detectors permits acquisition of the whole cardiac volume during a single 15-20 s breath-hold with a submillimetric definition of the images and an outstanding signal-to-noise ratio. Thus the race which, between MSCT, electron beam computed tomography and cardiac magnetic resonance imaging, can best provide routine and reliable imaging of the coronary arteries in clinical practice has recommenced. Currently available MSCT systems offer different options for both cardiac image acquisition and reconstruction, including multiplanar and curved multiplanar reconstruction, three-dimensional volume rendering, maximum intensity projection, and virtual angioscopy. In our preliminary experience including 176 patients suffering from known or suspected coronary artery disease, MSCT was feasible in 161 (91.5%) and showed a sensitivity of 80.4% and a specificity of 80.3%, with respect to standard coronary angiography, in detecting critical stenosis in coronary arteries and artery or venous bypass grafts. These results correspond to a positive predictive value of 58.6% and a negative predictive value of 92.2%. The true role that MSCT is likely to play in the future in non-invasive coronary imaging is still to be defined. Nevertheless, the huge amount of data obtainable by MSCT along with the rapid technological advances, shorter acquisition times and reconstruction algorithm developments will make the technique stronger, and possible applications are expected not only for non-invasive coronary angiography, but also for cardiac function and myocardial perfusion evaluation, as an all-in-one examination.

  16. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz, E-mail: moritzwildgruber@ukmuenster.de [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Institut für klinische Radiologie, Universitätsklinikum Münster, D-48149 Münster (Germany); Wrede, Christian E. [Notfallzentrum, Helios Klinikum Berlin-Buch, D-13125 Berlin (Germany); Zorger, Niels [Institut für Radiologie, Neuroradiologie und Nuklearmedizin, Krankenhaus Barmherzige Brüder, D-93049 Regensburg (Germany); Müller-Wille, René; Hamer, Okka W. [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Zeman, Florian [Zentrum für Klinische Studien, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Stroszczynski, Christian; Heiss, Peter [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany)

    2017-03-15

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  17. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Wildgruber, Moritz; Wrede, Christian E.; Zorger, Niels; Müller-Wille, René; Hamer, Okka W.; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-01-01

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  18. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Anuj [Department of Radiology, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)]. E-mail: dranujmish@yahoo.com; Bhaktarahalli, Jahnavi Narayanaswamy [Department of Clinical Pathology, Tripoli Medical Centre, Tripoli (Libyan Arab Jamahiriya); Ehtuish, Ehtuish F. [Department of Surgery, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)

    2007-03-15

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading.

  19. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    International Nuclear Information System (INIS)

    Mishra, Anuj; Bhaktarahalli, Jahnavi Narayanaswamy; Ehtuish, Ehtuish F.

    2007-01-01

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading

  20. Sublingual nitroglycerin administration in coronary computed tomography angiography: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P. [Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Sucha, Dominika; Leiner, Tim [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Park, Jakob [Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); University of Heidelberg, Department of Cardiology, Heidelberg (Germany); Hoffmann, Udo [Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2015-12-15

    To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography. A systematic search was performed in PubMed, EMBASE and Web of Science. The studies were evaluated for the effect of sublingual nitroglycerin on coronary artery diameter, evaluable segments, objective and subjective image quality, systemic physiological effects and diagnostic accuracy. Due to the heterogeneous reporting of outcome measures, a narrative synthesis was applied. Of the 217 studies identified, nine met the inclusion criteria: seven reported on the effect of nitroglycerin on coronary artery diameter, six on evaluable segments, four on image quality, five on systemic physiological effects and two on diagnostic accuracy. Sublingual nitroglycerin administration resulted in an improved evaluation of more coronary segments, in particular, in smaller coronary branches, better image quality and improved diagnostic accuracy. Side effects were mild and were alleviated without medical intervention. Sublingual nitroglycerin improves the coronary diameter, the number of assessable segments, image quality and diagnostic accuracy of coronary CT angiography without major side effects or systemic physiological changes. (orig.)

  1. Multislice Computed Tomography Coronary Angiography at a Local Hospital: Pitfalls and Potential

    Energy Technology Data Exchange (ETDEWEB)

    Kolnes, K.; Velle, Ose H.; Hareide, S.; Hegbom, K.; Wiseth, R. [Volda Hospital (Norway). Depts. of Radiology and Internal Medicine

    2006-09-15

    Purpose: To evaluate whether the favorable results achieved with multislice computed tomography (MSCT) of coronary arteries at larger centers could be paralleled at a local hospital. Material and Methods: Fifty consecutive patients with suspected coronary artery disease scheduled for invasive investigation with quantitative coronary angiography (QCA) at a university hospital underwent MSCT with a 16-slice scanner at a local hospital. Diagnostic accuracy of MSCT for coronary artery disease was assessed using a 16-segment coronary artery model with QCA as the gold standard. Results: Segments with diameter 50% stenosis for the 416 assessable segments were 92%, 82%, 53%, and 98%, respectively. Conclusion: Our beginners' experience demonstrated favorable results regarding sensitivity and negative predictive value. The positive predictive value, however, was unsatisfactory. Calcifications were identified as the most important factor for false-positive results with MSCT. With widespread use of MSCT coronary angiography, there is a risk of recruiting patients without significant coronary artery disease to unnecessary and potentially harmful invasive procedures.

  2. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  3. Evaluation of malposition of the branch pulmonary arteries using cardiovascular computed tomography angiography

    International Nuclear Information System (INIS)

    Liu, Hui; Juan, Yu-Hsiang; Wang, Qiushi; Huang, Hongfei; Yang, Lin; Xie, Zhaofeng; Chen, Jimei; Zhang, Xiaoshen; Liang, Changhong; Chung, Taylor; Kwong, Raymond Y.; Saboo, Sachin S.

    2014-01-01

    To analyze 15 cases of malposition of branch pulmonary arteries (MBPA) for the hospital-based prevalence, clinical information, surgical outcome, imaging findings, associated cardiovascular and airway abnormalities on cardiovascular computed tomography angiography (CCTA). We retrospectively searched for patients with MBPA from our database consisting of patients referred for CCTA due to known or suspected congenital heart disease and also from all patients receiving chest computed tomography (CT) during the same time period. We analyzed the hospital-based prevalence, image findings, associated cardiovascular anomalies, airway compression, and recorded the clinical information and surgical outcome. Our study showed 15 patients with MBPA (hospital-based prevalence: 0.33 % among patients with congenital heart disease and 0.06 % in all patients receiving chest CT or CCTA). Classic type was more common than lesser type (67 % versus 33 %). All patients had associated cardiovascular anomalies, including aortic arch abnormalities (80 %) and secondary airway compression (33 %). Surgery was performed in 67 % of cardiovascular anomalies and 60 % of airway stenoses. MBPA has a hospital-based prevalence of 0.33 % among patients with congenital heart disease and 0.06 % in all patients receiving either chest CT or CCTA. CCTA can delineate the anatomy of MBPA, associated cardiovascular and airway abnormalities for preoperative evaluation. (orig.)

  4. Evaluation of malposition of the branch pulmonary arteries using cardiovascular computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hui [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Brigham and Women' s Hospital, Harvard Medical School, Cardiovascular Imaging Program, Department of Medicine (Division of Cardiovascular Medicine) and Radiology, Boston, MA (United States); Juan, Yu-Hsiang [Brigham and Women' s Hospital, Harvard Medical School, Cardiovascular Imaging Program, Department of Medicine (Division of Cardiovascular Medicine) and Radiology, Boston, MA (United States); Chang Gung Memorial Hospital, Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Taoyuan (China); Wang, Qiushi; Huang, Hongfei; Yang, Lin [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Xie, Zhaofeng [Guangdong Academy of Medical Sciences, Department of Pediatric Cardiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Chen, Jimei; Zhang, Xiaoshen [Guangdong Academy of Medical Sciences, Department of Cardiovascular Surgery, Guangdong General Hospital, GuangZhou, GuangDong (China); Liang, Changhong [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, Guangzhou (China); Chung, Taylor [Children' s Hospital and Research Center Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); Kwong, Raymond Y.; Saboo, Sachin S. [Brigham and Women' s Hospital, Harvard Medical School, Cardiovascular Imaging Program, Department of Medicine (Division of Cardiovascular Medicine) and Radiology, Boston, MA (United States)

    2014-12-15

    To analyze 15 cases of malposition of branch pulmonary arteries (MBPA) for the hospital-based prevalence, clinical information, surgical outcome, imaging findings, associated cardiovascular and airway abnormalities on cardiovascular computed tomography angiography (CCTA). We retrospectively searched for patients with MBPA from our database consisting of patients referred for CCTA due to known or suspected congenital heart disease and also from all patients receiving chest computed tomography (CT) during the same time period. We analyzed the hospital-based prevalence, image findings, associated cardiovascular anomalies, airway compression, and recorded the clinical information and surgical outcome. Our study showed 15 patients with MBPA (hospital-based prevalence: 0.33 % among patients with congenital heart disease and 0.06 % in all patients receiving chest CT or CCTA). Classic type was more common than lesser type (67 % versus 33 %). All patients had associated cardiovascular anomalies, including aortic arch abnormalities (80 %) and secondary airway compression (33 %). Surgery was performed in 67 % of cardiovascular anomalies and 60 % of airway stenoses. MBPA has a hospital-based prevalence of 0.33 % among patients with congenital heart disease and 0.06 % in all patients receiving either chest CT or CCTA. CCTA can delineate the anatomy of MBPA, associated cardiovascular and airway abnormalities for preoperative evaluation. (orig.)

  5. A comparison of patient dose levels between 3/4 vessel conventional angiography and computed tomography angiography during examinations to investigate subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Spanton, David; Strudwick, Ruth M.

    2007-01-01

    The aim of this study was to investigate and compare the levels of ionising radiation dose received by patients whilst undergoing radiological examination for Subarachnoid haemorrhage by conventional angiography (single and bi plane) and computed tomography angiography. The results obtained from previous examinations have been compared to consider which method of investigation delivers the lowest ionising radiation dose to the patient. Consideration was also given to comparing single plane angiography to bi plane angiography as empirical evidence suggested that radiologists received no formal training and only a small amount of informal training on newly installed equipment at the hospital in which the research was carried out. Would this lead to patients being inadvertently exposed to increased radiation as radiologists familiarised themselves with the equipment? The dose received by 30 patients examined for SAH by each modality was converted to effective dose (mSv) for comparison. These results were then further compared by removing the lowest and highest recorded doses to eliminate any bias that may have been caused by skewed data. The results showed that CTA consistently delivered a lower dose to patients than single or bi plane angiography and that bi plane delivered a lower mean average dose than single plane angiography, with or without any skewed data

  6. Importance of oral fluid intake after coronary computed tomography angiography: An observational study

    International Nuclear Information System (INIS)

    Yoshikawa, Daiji; Isobe, Satoshi; Sato, Kimihide; Ohashi, Toshio; Fujiwara, Yuka; Ohyama, Hisato; Ishii, Hideki; Murohara, Toyoaki

    2011-01-01

    Background: The prevention of contrast-induced acute kidney injury (AKI) after coronary computed tomography angiography (CCTA) is important because patients referred for CCTA often need further contrast exposure such as an invasive coronary angiography. We aimed to examine the effects of oral volume intake on renal function in patients with preserved renal function referred for CCTA. Methods: We enrolled 180 patients who were referred for CCTA. The serum creatinine (SCr) and estimated glomerular filtration rate (eGFR) levels were measured before, 24 h, and a mean of 4.8 days after CCTA. The amount of unrestricted oral fluid intake for 24 h was checked. The patients were divided into two groups: 106 subjects with a rise in SCr after CCTA (group A); and 74 without (group B). Results: Significant correlations were observed between the amount of oral fluid intake and the percentage changes in SCr (%SCr) (r = -0.66, p < 0.0001) as well as the absolute changes in eGFR (ΔeGFR) (r = 0.65, p < 0.0001). The percentage of patients showing hemoglobin-A1c (HbA1c) ≥ 6.5% was greater in group A than in group B (29% vs. 18%, p < 0.001). Patients with HbA1c ≥ 6.5% showed higher %SCr and lower ΔeGFR compared to those without it. Multiple regression analysis revealed that the amount of oral fluid intake was the only independent predictor for a rise in SCr (β = -0.731, p < 0.0001). Conclusion: Oral volume intake after CCTA is a very simple but important prophylactic procedure for contrast-induced AKI especially in diabetic patients.

  7. Importance of oral fluid intake after coronary computed tomography angiography: An observational study

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Daiji [Department of Cardiology, Nagoya University Graduate School of Medicine (Japan); Department of Cardiology, Kami-iida Daiichi General Hospital, Nagoya (Japan); Isobe, Satoshi, E-mail: sisobe@med.nagoya-u.ac.jp [Department of Cardiology, Nagoya University Graduate School of Medicine (Japan); Department of Cardiology, Kami-iida Daiichi General Hospital, Nagoya (Japan); Sato, Kimihide; Ohashi, Toshio [Division of Radiology, Kami-iida Daiichi General Hospital, Nagoya (Japan); Fujiwara, Yuka; Ohyama, Hisato [Division of Nursing, Kami-iida Daiichi General Hospital, Nagoya (Japan); Ishii, Hideki; Murohara, Toyoaki [Department of Cardiology, Nagoya University Graduate School of Medicine (Japan)

    2011-01-15

    Background: The prevention of contrast-induced acute kidney injury (AKI) after coronary computed tomography angiography (CCTA) is important because patients referred for CCTA often need further contrast exposure such as an invasive coronary angiography. We aimed to examine the effects of oral volume intake on renal function in patients with preserved renal function referred for CCTA. Methods: We enrolled 180 patients who were referred for CCTA. The serum creatinine (SCr) and estimated glomerular filtration rate (eGFR) levels were measured before, 24 h, and a mean of 4.8 days after CCTA. The amount of unrestricted oral fluid intake for 24 h was checked. The patients were divided into two groups: 106 subjects with a rise in SCr after CCTA (group A); and 74 without (group B). Results: Significant correlations were observed between the amount of oral fluid intake and the percentage changes in SCr (%SCr) (r = -0.66, p < 0.0001) as well as the absolute changes in eGFR ({Delta}eGFR) (r = 0.65, p < 0.0001). The percentage of patients showing hemoglobin-A1c (HbA1c) {>=} 6.5% was greater in group A than in group B (29% vs. 18%, p < 0.001). Patients with HbA1c {>=} 6.5% showed higher %SCr and lower {Delta}eGFR compared to those without it. Multiple regression analysis revealed that the amount of oral fluid intake was the only independent predictor for a rise in SCr ({beta} = -0.731, p < 0.0001). Conclusion: Oral volume intake after CCTA is a very simple but important prophylactic procedure for contrast-induced AKI especially in diabetic patients.

  8. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Energy Technology Data Exchange (ETDEWEB)

    Araujo-Neto, Severino Aires; Mello-Junior, Carlos Fernando de; Franca, Henrique Almeida; Duarte, Claudia Martina Araujo; Borges, Rafael Farias; Magalhaes, Ana Guardiana Ximenes de, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2016-01-15

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  9. Influence of Adaptive Statistical Iterative Reconstruction on coronary plaque analysis in coronary computed tomography angiography.

    Science.gov (United States)

    Precht, Helle; Kitslaar, Pieter H; Broersen, Alexander; Dijkstra, Jouke; Gerke, Oke; Thygesen, Jesper; Egstrup, Kenneth; Lambrechtsen, Jess

    The purpose of this study was to study the effect of iterative reconstruction (IR) software on quantitative plaque measurements in coronary computed tomography angiography (CCTA). Thirty patients with a three clinical risk factors for coronary artery disease (CAD) had one CCTA performed. Images were reconstructed using FBP, 30% and 60% adaptive statistical IR (ASIR). Coronary plaque analysis was performed as per patient and per vessel (LM, LAD, CX and RCA) measurements. Lumen and vessel volumes and plaque burden measurements were based on automatic detected contours in each reconstruction. Lumen and plaque intensity measurements and HU based plaque characterization were based on corrected contours copied to each reconstruction. No significant changes between FBP and 30% ASIR were found except for lumen- (-2.53 HU) and plaque intensities (-1.28 HU). Between FBP and 60% ASIR the change in total volume showed an increase of 0.94%, 4.36% and 2.01% for lumen, plaque and vessel, respectively. The change in total plaque burden between FBP and 60% ASIR was 0.76%. Lumen and plaque intensities decreased between FBP and 60% ASIR with -9.90 HU and -1.97 HU, respectively. The total plaque component volume changes were all small with a maximum change of -1.13% of necrotic core between FBP and 60% ASIR. Quantitative plaque measurements only showed modest differences between FBP and the 60% ASIR level. Differences were increased lumen-, vessel- and plaque volumes, decreased lumen- and plaque intensities and a small percentage change in the individual plaque component volumes. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  10. Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteries

    International Nuclear Information System (INIS)

    Ferencik, Maros; Nomura, Cesar H.; Maurovich-Horvat, Pal; Hoffmann, Udo; Pena, Antonio J.; Cury, Ricardo C.; Abbara, Suhny; Nieman, Koen; Fatima, Umaima; Achenbach, Stephan; Brady, Thomas J.

    2006-01-01

    We explored quantitative parameters of image quality in consecutive patients undergoing 64-slice multi-detector computed tomography (MDCT) coronary angiography for clinical reasons. Forty-two patients (36 men, mean age 61 ± 11 years, mean heart rate 63 ± 10 bpm) underwent contrast-enhanced MDCT coronary angiography with a 64-slice scanner (Siemens Sensation 64, 64 mmx 0.6 mm collimation, 330 ms tube rotation, 850 mAs, 120 kV). Two independent observers measured the overall visualized vessel length and the length of the coronary arteries visualized without motion artifacts in curved multiplanar reformatted images. Contrast-to-noise ratio was measured in the proximal and distal segments of the coronary arteries. The mean length of visualized coronary arteries was: left main 12 ± 6 mm, left anterior descending 149 ± 25 mm, left circumflex 89 ± 30 mm, and right coronary artery 161 ± 38 mm. On average, 97 ± 5% of the total visualized vessel length was depicted without motion artifacts (left main 100 ± 0%, left anterior descending 97 ± 6%, left circumflex 98 ± 5%, and right coronary artery 95 ± 6%). In 27 patients with a heart rate ≤65 bpm, 98 ± 4% of the overall visualized vessel length was imaged without motion artifacts, whereas 96 ± 6% of the overall visualized vessel length was imaged without motion artifacts in 15 patients with a heart rate >65 bpm (p < 0.001). The mean contrast-to-noise ratio in all measured coronary arteries was 14.6 ± 4.7 (proximal coronary segments: range 15.1 ± 4.4 to 16.1 ± 5.0, distal coronary segments: range 11.4 ± 4.2 to 15.9 ± 4.9). In conclusion, 64-slice MDCT permits reliable visualization of the coronary arteries with minimal motion artifacts and high CNR in consecutive patients referred for non-invasive MDCT coronary angiography. Low heart rate is an important prerequisite for excellent image quality

  11. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound

    OpenAIRE

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Śpiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin

    2013-01-01

    Introduction Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. Aim To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Material and methods Two hundred and...

  12. Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography.

    Science.gov (United States)

    Precht, Helle; Thygesen, Jesper; Gerke, Oke; Egstrup, Kenneth; Waaler, Dag; Lambrechtsen, Jess

    2016-12-01

    Coronary computed tomography angiography (CCTA) requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR) techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure. To evaluate whether adaptive statistical iterative reconstruction (ASIR) enhances perceived image quality in CCTA compared to filtered back projection (FBP). Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA) and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR]) was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data. VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR ( P  = 0.004). The objective measures showed significant differences between FBP and 60% ASIR ( P  < 0.0001) for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26. ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

  13. CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    Science.gov (United States)

    Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo

    2018-04-01

    Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.

  14. Computed tomography versus invasive coronary angiography: design and methods of the pragmatic randomised multicentre DISCHARGE trial

    International Nuclear Information System (INIS)

    Napp, Adriane E.; Haase, Robert; Schuetz, Georg M.; Rief, Matthias; Katzer, Christoph; Dewey, Marc; Laule, Michael; Dreger, Henryk; Feuchtner, Gudrun; Friedrich, Guy; Spacek, Miloslav; Suchanek, Vojtech; Fuglsang Kofoed, Klaus; Engstroem, Thomas; Schroeder, Stephen; Drosch, Tanja; Gutberlet, Matthias; Woinke, Michael; Maurovich-Horvat, Pal; Merkely, Bela; Donnelly, Patrick; Ball, Peter; Dodd, Jonathan D.; Quinn, Martin; Saba, Luca; Porcu, Maurizio; Francone, Marco; Mancone, Massimo; Erglis, Andrejs; Zvaigzne, Ligita; Jankauskas, Antanas; Sakalyte, Gintare; Haran, Tomasz; Ilnicka-Suckiel, Malgorzata; Bettencourt, Nuno; Gama-Ribeiro, Vasco; Condrea, Sebastian; Benedek, Imre; Cemerlic Adjic, Nada; Adjic, Oto; Rodriguez-Palomares, Jose; Garcia del Blanco, Bruno; Roditi, Giles; Berry, Colin; Davis, Gershan; Thwaite, Erica; Knuuti, Juhani; Pietilae, Mikko; Kepka, Cezary; Kruk, Mariusz; Vidakovic, Radosav; Neskovic, Aleksandar N.; Diez, Ignacio; Lecumberri, Inigo; Geleijns, Jacob; Kubiak, Christine; Strenge-Hesse, Anke; Do, The-Hoang; Froemel, Felix; Gutierrez-Ibarluzea, Inaki; Benguria-Arrate, Gaizka; Keiding, Hans; Mueller-Nordhorn, Jacqueline; Rieckmann, Nina; Walther, Mario; Schlattmann, Peter

    2017-01-01

    More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninvasive test for detection and exclusion of coronary artery disease (CAD). To investigate the comparative effectiveness of CT and ICA, we designed the European pragmatic multicentre DISCHARGE trial funded by the 7th Framework Programme of the European Union (EC-GA 603266). In this trial, patients with a low-to-intermediate pretest probability (10-60 %) of suspected CAD and a clinical indication for ICA because of stable chest pain will be randomised in a 1-to-1 ratio to CT or ICA. CT and ICA findings guide subsequent management decisions by the local heart teams according to current evidence and European guidelines. Major adverse cardiovascular events (MACE) defined as cardiovascular death, myocardial infarction and stroke as a composite endpoint will be the primary outcome measure. Secondary and other outcomes include cost-effectiveness, radiation exposure, health-related quality of life (HRQoL), socioeconomic status, lifestyle, adverse events related to CT/ICA, and gender differences. The DISCHARGE trial will assess the comparative effectiveness of CT and ICA. (orig.)

  15. Computed tomography versus invasive coronary angiography: design and methods of the pragmatic randomised multicentre DISCHARGE trial

    Energy Technology Data Exchange (ETDEWEB)

    Napp, Adriane E.; Haase, Robert; Schuetz, Georg M.; Rief, Matthias; Katzer, Christoph; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Laule, Michael; Dreger, Henryk [Charite - Universitaetsmedizin Berlin, Department of Cardiology, Berlin (Germany); Feuchtner, Gudrun [Medical University Innsbruck, Department of Radiology, Innsbruck (Austria); Friedrich, Guy [Medical University Innsbruck, Department of Cardiology, Innsbruck (Austria); Spacek, Miloslav [University Hospital Motol, Department of Cardiology, Prague (Czech Republic); Suchanek, Vojtech [University Hospital Motol, Department of Radiology, Prague (Czech Republic); Fuglsang Kofoed, Klaus [Rigshospitalet Region Hovedstaden, Department of Radiology and Department of Cardiology, Copenhagen (Denmark); Engstroem, Thomas [Rigshospitalet Region Hovedstaden, Department of Cardiology, Copenhagen (Denmark); Schroeder, Stephen; Drosch, Tanja [ALB FILS KLINIKEN GmbH, Department of Cardiology, Goeppingen (Germany); Gutberlet, Matthias [University of Leipzig Heart Centre, Department of Radiology, Leipzig (Germany); Woinke, Michael [University of Leipzig Heart Centre, Department of Cardiology, Leipzig (Germany); Maurovich-Horvat, Pal; Merkely, Bela [Semmelweis University, MTA-SE Cardiovascular Imaging Center, Heart and Vascular Center, Budapest (Hungary); Donnelly, Patrick [Southeastern Health and Social Care Trust, Department of Cardiology, Belfast (United Kingdom); Ball, Peter [Southeastern Health and Social Care Trust, Department of Radiology, Belfast (United Kingdom); Dodd, Jonathan D. [St. Vincent' s University Hospital and National University of Ireland, Department of Radiology, Dublin (Ireland); Quinn, Martin [St. Vincent' s University Hospital, Department of Cardiology, Dublin (Ireland); Saba, Luca [Azienda Ospedaliero Universitaria di Cagliari, Department of Radiology, Monserrato (Italy); Porcu, Maurizio [Azienda Ospedaliera Brotzu, Department of Cardiology, Cagliari (Italy); Francone, Marco [Sapienza University of Rome, Department of Radiology, Rome (Italy); Mancone, Massimo [Sapienza University of Rome, Department of Cardiovascular, Respiratory, Nephrology, Anesthesiology and Geriatric Sciences, Rome (Italy); Erglis, Andrejs [Paul Stradins Clinical University Hospital, Department of Cardiology, Riga (Latvia); Zvaigzne, Ligita [Paul Stradins Clinical University Hospital, Department of Radiology, Riga (Latvia); Jankauskas, Antanas [Lithuanian University of Health Sciences, Department of Radiology, Kaunas (Lithuania); Sakalyte, Gintare [Lithuanian University of Health Sciences, Department of Cardiology, Kaunas (Lithuania); Haran, Tomasz [Wojewodzki Szpital Specjalistyczny We Wroclawiu, Department of Radiology, Wroclaw (Poland); Ilnicka-Suckiel, Malgorzata [Wojewodzki Szpital Specjalistyczny We Wroclawiu, Department of Cardiology, Wroclaw (Poland); Bettencourt, Nuno; Gama-Ribeiro, Vasco [Centro Hospitalar de Vila Nova de Gaia, Department of Cardiology, Vila Nova de Gaia (Portugal); Condrea, Sebastian; Benedek, Imre [Cardio Med Medical Center, Department of Cardiology, Targu-Mures (Romania); Cemerlic Adjic, Nada [Institute of Cardiovascular Diseases of Vojvodina, Department of Cardiology, Novi Sad, Sremska Kamenica (Serbia); Adjic, Oto [Institute of Cardiovascular Diseases of Vojvodina, Radiology Department Imaging Center, Novi Sad, Sremska Kamenica (Serbia); Rodriguez-Palomares, Jose; Garcia del Blanco, Bruno [Universitat Autonoma de Barcelona, Department of Cardiology (Barcelona Spain), Hospital Universitari Vall d' Hebron, Institut de Recerca (VHIR), Barcelona (ES); Roditi, Giles; Berry, Colin [University of Glasgow, Institute of Cardiovascular and Medical Sciences, Glasgow (GB); Davis, Gershan [Aintree University Hospital, Department of Cardiology, Liverpool (GB); Thwaite, Erica [Aintree University Hospital, Department of Radiology, Liverpool (GB); Knuuti, Juhani [Turku University Hospital and University of Turku, Turku PET Centre, Turku (FI); Pietilae, Mikko [Turku University Hospital, Heart Centre, Turku (FI); Kepka, Cezary [The Institute of Cardiology in Warsaw, Department of Radiology, Warsaw (PL); Kruk, Mariusz [The Institute of Cardiology in Warsaw, Department of Cardiology, Warsaw (PL); Vidakovic, Radosav; Neskovic, Aleksandar N. [Clinical Hospital Center Zemun, Department of Cardiology, Belgrade-Zemun (RS); Diez, Ignacio [Basurto University Hospital, Department of Cardiology, Bilbao (ES); Lecumberri, Inigo [Basurto University Hospital, Department of Radiology, Bilbao (ES); Geleijns, Jacob [Leiden University Medical Center, Department of Radiology, Leiden (NL); Kubiak, Christine [European Clinical Research Infrastructure Network (ECRIN-ERIC), Management Office, Paris (FR); Strenge-Hesse, Anke [University Cologne, European Clinical Research Infrastructure Network (ECRIN-ERIC), National ECRIN office/KKS Network, Cologne (DE); Do, The-Hoang; Froemel, Felix [Charite - Universitaetsmedizin Berlin, Clinical Coordinating Centre, Berlin (DE); Gutierrez-Ibarluzea, Inaki; Benguria-Arrate, Gaizka [Basque Office for Health Technology Assessment, Vitoria-Gasteiz (ES); Keiding, Hans [University of Copenhagen, Department of Economics, Department of Economics, Copenhagen (DK); Mueller-Nordhorn, Jacqueline; Rieckmann, Nina [Charite - Universitaetsmedizin Berlin, Institute of Public Health, Berlin (DE); Walther, Mario; Schlattmann, Peter [Jena University Hospital, Friedrich Schiller University Jena, Institute of Medical Statistics, Computer Sciences and Documentation, Jena (DE); Collaboration: The DISCHARGE Trial Group

    2017-07-15

    More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninvasive test for detection and exclusion of coronary artery disease (CAD). To investigate the comparative effectiveness of CT and ICA, we designed the European pragmatic multicentre DISCHARGE trial funded by the 7th Framework Programme of the European Union (EC-GA 603266). In this trial, patients with a low-to-intermediate pretest probability (10-60 %) of suspected CAD and a clinical indication for ICA because of stable chest pain will be randomised in a 1-to-1 ratio to CT or ICA. CT and ICA findings guide subsequent management decisions by the local heart teams according to current evidence and European guidelines. Major adverse cardiovascular events (MACE) defined as cardiovascular death, myocardial infarction and stroke as a composite endpoint will be the primary outcome measure. Secondary and other outcomes include cost-effectiveness, radiation exposure, health-related quality of life (HRQoL), socioeconomic status, lifestyle, adverse events related to CT/ICA, and gender differences. The DISCHARGE trial will assess the comparative effectiveness of CT and ICA. (orig.)

  16. An Audit on the Appropriateness of Coronary Computed Tomography Angiography Referrals in a Tertiary Cardiac Center.

    Science.gov (United States)

    Alderazi, Ahmed Ali; Lynch, Mary

    2017-01-01

    In response to growing concerns regarding the overuse of coronary computed tomography angiography (CCTA) in the clinical setting, multiple societies, including the American College of Cardiology Foundation, have jointly published revised criteria regarding the appropriate use of this imaging modality. However, previous research indicates significant discrepancies in the rate of adherence to these guidelines. To assess the appropriateness of CCTA referrals in a tertiary cardiac center in Bahrain. This retrospective clinical audit examined the records of patients referred to CCTA between the April 1, 2015 and December 31, 2015 in Mohammed bin Khalifa Cardiac Center. Using information from medical records, each case was meticulously audited against guidelines to categorize it as appropriate, inappropriate, or uncertain. Of the 234 records examined, 176 (75.2%) were appropriate, 47 (20.1%) were uncertain, and 11 (4.7%) were inappropriate. About 74.4% of all referrals were to investigate coronary artery disease (CAD). The most common indication that was deemed appropriate was the detection of CAD in the setting of suspected ischemic equivalent in patients with an intermediate pretest probability of CAD (65.9%). Most referrals deemed inappropriate were requested to detect CAD in asymptomatic patients at low or intermediate risk of CAD (63.6%). This audit demonstrates a relatively low rate of inappropriate CCTA referrals, indicating the appropriate and efficient use of this resource in the Mohammed bin Khalifa Cardiac Center. Agreement on and reclassification of "uncertain" cases by guideline authorities would facilitate a deeper understanding of referral appropriateness.

  17. Creating vascular models by postprocessing computed tomography angiography images: a guide for anatomical education.

    Science.gov (United States)

    Govsa, Figen; Ozer, Mehmet Asim; Sirinturk, Suzan; Eraslan, Cenk; Alagoz, Ahmet Kemal

    2017-08-01

    A new application of teaching anatomy includes the use of computed tomography angiography (CTA) images to create clinically relevant three-dimensional (3D) printed models. The purpose of this article is to review recent innovations on the process and the application of 3D printed models as a tool for using under and post-graduate medical education. Images of aortic arch pattern received by CTA were converted into 3D images using the Google SketchUp free software and were saved in stereolithography format. Using a 3D printer (Makerbot), a model mode polylactic acid material was printed. A two-vessel left aortic arch was identified consisting of the brachiocephalic trunk and left subclavian artery. The life-like 3D models were rotated 360° in all axes in hand. The early adopters in education and clinical practices have embraced the medical imaging-guided 3D printed anatomical models for their ability to provide tactile feedback and a superior appreciation of visuospatial relationship between the anatomical structures. Printed vascular models are used to assist in preoperative planning, develop intraoperative guidance tools, and to teach patients surgical trainees in surgical practice.

  18. Computed tomography angiography study of variations of the celiac trunk and hepatic artery in 100 patients

    Energy Technology Data Exchange (ETDEWEB)

    Brasil, Ivelise Regina Canito; Araujo, Igor Farias de; Lima, Adriana Augusta Lopes de Araujo; Melo, Ernesto Lima Araujo; Esmeraldo, Ronaldo de Matos, E-mail: igor_farias98@hotmail.com [Universidade Estadual do Ceará (UECE), Fortaleza, CE (Brazil). Escola de Medicina

    2018-01-15

    Objective: To describe the main anatomical variations of the celiac trunk and the hepatic artery at their origins. Materials and methods: This was a prospective analysis of 100 consecutive computed tomography angiography studies of the abdomen performed during a one-year period. The findings were stratified according to classification systems devised by Sureka et al. and Michels. Results: The celiac trunk was 'normal' (i.e., the hepatogastrosplenic trunk and superior mesenteric artery originating separately from the abdominal aorta) in 43 patients. In our sample, we identified four types of variations of the celiac trunk. Regarding the hepatic artery, a normal anatomical pattern (i.e., the proper hepatic artery being a continuation of the common hepatic artery and bifurcating into the right and left hepatic arteries) was seen in 82 patients. We observed six types of variations of the hepatic artery. Conclusion: We found rates of variations of the hepatic artery that are different from those reported in the literature. Our findings underscore the need for proper knowledge and awareness of these anatomical variations, which can facilitate their recognition and inform decisions regarding the planning of surgical procedures, in order to avoid iatrogenic intraoperative injuries, which could lead to complications. (author)

  19. Isolated unilateral absence of the right pulmonary artery in two cats visualized by computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Tyler JM Jordan

    2016-10-01

    Full Text Available Case series summary Two cats were evaluated for progressive exercise intolerance, dyspnea and unilateral infiltrate of the left lung. Computed tomography angiography (CTA revealed absence of the right pulmonary artery in both cats with systemic arterial collateral vessels perfusing the right segmental pulmonary arteries. In one case, the collateral vessels arose from the esophageal artery, while in the other case they derived off the right costocervical trunk. One cat was diagnosed with pulmonary hypertension and was euthanized owing to progressive respiratory distress despite medical management with sildenafil, pimobendan, clopidogrel and furosemide. The other cat, without echocardiographic evidence of pulmonary hypertension, was successfully managed with furosemide and enalapril for more than 4 years. Relevance and novel information CTA allowed visualization of a rare congenital heart malformation, unilateral absence of the right pulmonary artery, in two cats and accurately characterized the source of collateral blood supply to the affected lung. Severe pulmonary hypertension may be a negative prognostic factor in cats with this condition as medical therapy in the cat without evidence of pulmonary hypertension resolved clinical signs, while the cat with severe pulmonary hypertension died from the disease.

  20. Computed tomography angiography study of variations of the celiac trunk and hepatic artery in 100 patients

    Directory of Open Access Journals (Sweden)

    Ivelise Regina Canito Brasil

    Full Text Available Abstract Objective: To describe the main anatomical variations of the celiac trunk and the hepatic artery at their origins. Materials and Methods: This was a prospective analysis of 100 consecutive computed tomography angiography studies of the abdomen performed during a one-year period. The findings were stratified according to classification systems devised by Sureka et al. and Michels. Results: The celiac trunk was "normal" (i.e., the hepatogastrosplenic trunk and superior mesenteric artery originating separately from the abdominal aorta in 43 patients. In our sample, we identified four types of variations of the celiac trunk. Regarding the hepatic artery, a normal anatomical pattern (i.e., the proper hepatic artery being a continuation of the common hepatic artery and bifurcating into the right and left hepatic arteries was seen in 82 patients. We observed six types of variations of the hepatic artery. Conclusion: We found rates of variations of the hepatic artery that are different from those reported in the literature. Our findings underscore the need for proper knowledge and awareness of these anatomical variations, which can facilitate their recognition and inform decisions regarding the planning of surgical procedures, in order to avoid iatrogenic intraoperative injuries, which could lead to complications.

  1. Computed Tomography Angiography Evaluation of Risk Factors for Unstable Intracranial Aneurysms.

    Science.gov (United States)

    Wang, Guang-Xian; Gong, Ming-Fu; Wen, Li; Liu, Lan-Lan; Yin, Jin-Bo; Duan, Chun-Mei; Zhang, Dong

    2018-03-19

    To evaluate risk factors for instability in intracranial aneurysms (IAs) using computed tomography angiography (CTA). A total of 614 consecutive patients diagnosed with 661 IAs between August 2011 and February 2016 were reviewed. Patients and IAs were divided into stable and unstable groups. Along with clinical characteristics, IA characteristics were evaluated by CTA. Multiple logistic regression analysis was used to identify the independent risk factors associated with unstable IAs. Receiver operating characteristic (ROC) curve analysis was performed on the final model, and optimal thresholds were obtained. Patient age (odds ratio [OR], 0.946), cerebral atherosclerosis (CA; OR, 0.525), and IAs located at the middle cerebral artery (OR, 0.473) or internal carotid artery (OR, 0.512) were negatively correlated with instability, whereas IAs with irregular shape (OR, 2.157), deep depth (OR, 1.557), or large flow angle (FA; OR, 1.015) were more likely to be unstable. ROC analysis revealed threshold values of age, depth, and FA of 59.5 years, 4.25 mm, and 87.8°, respectively. The stability of IAs is significantly affected by several factors, including patient age and the presence of CA. IA shape and location also have an impact on the stability of IAs. Growth into an irregular shape, with a deep depth, and a large FA are risk factors for a change in IAs from stable to unstable. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. 320-row detector computed tomography angiography findings of a case with multiple

    International Nuclear Information System (INIS)

    Akay, S.; Bozlar, U.; Demirkol, S.; Tasar, M.

    2012-01-01

    Full text: Introduction: Computed tomography angiography (CTA) with three-dimensional imaging capability is a very reliable imaging modality for the evaluation of the coronary arteries. Objectives and tasks: To discuss the 320-row detector CTA findings of a case with multiple coronary artery course anomaly. Materials and methods: A 46-year-old man with palpitation, admitted to Cardiology department of our hospital. On electrocardiography, polymorphic ventricular early beats were observed. The patient was referred to Radiology department for CTA examination in terms of probable coronary artery anomaly. Results: On CTA, left main coronary artery was short. The bridging causes nearly 75% luminal stenosis was observed in the middle part of left descending artery. Circumflex artery was continuing as the first obtuse margin and this branch was separating to four branches in the middle part. They were coursing subepicardially in the middle and distal part. Right main coronary artery has also subepicardial course in its middle and distal part. Conclusion: Myocardial bridging is not a rare situation in routine clinical practice. But bridging in all of the three coronary arteries is very uncommon. Multidetector CTA is an effective and non-invasive imaging modality for understanding the normal anatomy and detecting the congenital anomalies of the coronary arteries

  3. The clinical usefulness evaluation of normal saline injection in coronary artery computed tomography angiography (Coronary CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kang Kyo; Lee, Mi Hwa; Cho, Pyong Kon [Dept. of Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2014-12-15

    The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about 4.8±0.3 bpm (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less 6.0±1.0 mSv (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation.

  4. Computed Tomography Pulmonary Angiography for Evaluation of Patients With Suspected Pulmonary Embolism: Use or Overuse

    International Nuclear Information System (INIS)

    Molaee, Shima; Ghanaati, Hossein; Safavi, Enayat; Foroumandi, Morteza; Peiman, Soheil

    2015-01-01

    The use of computed tomography pulmonary angiography (CTPA) has been increased during the last decade. We studied the adherence to current diagnostic recommendations for evaluation of pulmonary embolism in a teaching hospital of Tehran University of Medical Sciences. The registered medical records (Wells scores and serum D-dimer level) of all patients whose CTPA was performed with suspicion of pulmonary thromboembolism (PTE) were studied retrospectively. Modified Wells score of each patient was determined without being aware of the CTPA results. The patients were categorized to those with a high (likely) clinical probability (score > 4) and low (unlikely) clinical probability (score≤ 4) of PTE. During a 6-month period, 82 patients who underwent CTPA were included. The prevalence of PTE was 62.2% in the group of subjects with a likely clinical risk. In 45 (54.8%) of those patients whose CTPA was requested, the PTE was unlikely based on modified Wells criteria. In the clinically unlikely group, serum D-dimer assay was done in 15 out of 45 (33.3%), while it was inappropriately checked in 10 out of 37 (27.0%) with a clinically likely risk. General adherence rate to diagnostic algorithm of PTE was 43.9%. There is still excessive unjustified concern of PTE in less trained physicians leading to excessive diagnostic work-up. Loyalty to the existing guideline for management of suspected PTE in educational hospitals and supervision of attending physicians could prevent overuse of CTPA

  5. The hemodynamics in intracranial aneurysm ruptured region with active contrast leakage during computed tomography angiography

    Science.gov (United States)

    Li, Ming-Lung; Wang, Yi-Chou; Liou, Tong-Miin; Lin, Chao-An

    2014-10-01

    Precise locations of rupture region under contrast agent leakage of five ruptured cerebral artery aneurysms during computed tomography angiography, which is to our knowledge for the first time, were successfully identified among 101 patients. These, together with numerical simulations based on the reconstructed aneurysmal models, were used to analyze hemodynamic parameters of aneurysms under different cardiac cyclic flow rates. For side wall type aneurysms, different inlet flow rates have mild influences on the shear stresses distributions. On the other hand, for branch type aneurysms, the predicted wall shear stress (WSS) correlates strongly with the increase of inlet vessel velocity. The mean and time averaged WSSes at rupture regions are found to be lower than those over the surface of the aneurysms. Also, the levels of the oscillatory shear index (OSI) are higher than the reported threshold value, supporting the assertion that high OSI correlates with rupture of the aneurysm. However, the present results also indicate that OSI level at the rupture region is relatively lower.

  6. The clinical usefulness evaluation of normal saline injection in coronary artery computed tomography angiography (Coronary CTA)

    International Nuclear Information System (INIS)

    Jung, Kang Kyo; Lee, Mi Hwa; Cho, Pyong Kon

    2014-01-01

    The purpose of this study is that in coronary artery angiography computed tomography (coronary CTA), to gain high quality of image and to use low dose radiation by administrating normal saline and converting the mode of scanning heart rate (HR) characteristics before infusing contrast media. All patients data (total specimens: 200, male: 108, female: 92) were measured by using appropriate mode of scanning the heart rate (HR) after injection of saline. in addition we measured radiation dose (CTDIvol, effective dose) in all examinations. CT number and noise, and blurring of coronary artery (proximal RCA, middle RCA, proximal LCA) were measured and compared. The result of this study after injection of saline, mean heart rate was decreased about 4.8±0.3 bpm (beats per minute). 33 patients (13%) got converting scan mode due to reducing heart rate (HR). In prospective gating mode, radiation dose were measured less 6.0±1.0 mSv (54.1%) than retrospective gating mode. Also showed a significant difference in heart rate decrease in image evaluation

  7. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    Science.gov (United States)

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  8. Automatic segmentation of coronary arteries from computed tomography angiography data cloud using optimal thresholding

    Science.gov (United States)

    Ansari, Muhammad Ahsan; Zai, Sammer; Moon, Young Shik

    2017-01-01

    Manual analysis of the bulk data generated by computed tomography angiography (CTA) is time consuming, and interpretation of such data requires previous knowledge and expertise of the radiologist. Therefore, an automatic method that can isolate the coronary arteries from a given CTA dataset is required. We present an automatic yet effective segmentation method to delineate the coronary arteries from a three-dimensional CTA data cloud. Instead of a region growing process, which is usually time consuming and prone to leakages, the method is based on the optimal thresholding, which is applied globally on the Hessian-based vesselness measure in a localized way (slice by slice) to track the coronaries carefully to their distal ends. Moreover, to make the process automatic, we detect the aorta using the Hough transform technique. The proposed segmentation method is independent of the starting point to initiate its process and is fast in the sense that coronary arteries are obtained without any preprocessing or postprocessing steps. We used 12 real clinical datasets to show the efficiency and accuracy of the presented method. Experimental results reveal that the proposed method achieves 95% average accuracy.

  9. Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material.

    Science.gov (United States)

    Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito

    2014-01-01

    The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.  

  10. Computed tomography angiography study of variations of the celiac trunk and hepatic artery in 100 patients

    International Nuclear Information System (INIS)

    Brasil, Ivelise Regina Canito; Araujo, Igor Farias de; Lima, Adriana Augusta Lopes de Araujo; Melo, Ernesto Lima Araujo; Esmeraldo, Ronaldo de Matos

    2018-01-01

    Objective: To describe the main anatomical variations of the celiac trunk and the hepatic artery at their origins. Materials and methods: This was a prospective analysis of 100 consecutive computed tomography angiography studies of the abdomen performed during a one-year period. The findings were stratified according to classification systems devised by Sureka et al. and Michels. Results: The celiac trunk was 'normal' (i.e., the hepatogastrosplenic trunk and superior mesenteric artery originating separately from the abdominal aorta) in 43 patients. In our sample, we identified four types of variations of the celiac trunk. Regarding the hepatic artery, a normal anatomical pattern (i.e., the proper hepatic artery being a continuation of the common hepatic artery and bifurcating into the right and left hepatic arteries) was seen in 82 patients. We observed six types of variations of the hepatic artery. Conclusion: We found rates of variations of the hepatic artery that are different from those reported in the literature. Our findings underscore the need for proper knowledge and awareness of these anatomical variations, which can facilitate their recognition and inform decisions regarding the planning of surgical procedures, in order to avoid iatrogenic intraoperative injuries, which could lead to complications. (author)

  11. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

    International Nuclear Information System (INIS)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao; Failla, Bruna Bonaventura

    2013-01-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  12. Male Gender and Arterial Hypertension are Plaque Predictors at Coronary Computed Tomography Angiography

    Science.gov (United States)

    Oliveira, Joselina Luzia Menezes; Hirata, Mario Hiroyuki; Sousa, Amanda Guerra de Moraes Rego; Gabriel, Fabíola Santos; Hirata, Thiago Dominguez Crespo; Tavares, Irlaneide da Silva; Melo, Luiza Dantas; Dória, Fabiana de Santana; Sousa, Antônio Carlos Sobral; Pinto, Ibraim Masciarelli Francisco

    2015-01-01

    Background Systemic Arterial Hypertension (SAH) is one of the main risk factors for Coronary Artery Disease (CAD), in addition to male gender. Differences in coronary artery lesions between hypertensive and normotensive individuals of both genders at the Coronary Computed Tomography Angiography (CCTA) have not been clearly determined. Objective To Investigate the calcium score (CS), CAD extent and characteristics of coronary plaques at CCTA in men and women with and without SAH. Methods Prospective cross-sectional study of 509 patients undergoing CCTA for CAD diagnosis and risk stratification, from November 2011 to December 2012, at Instituto de Cardiologia Dante Pazzanese. Individuals were stratified according to gender and subdivided according to the presence (HT +) or absence (HT-) of SAH. Results HT+ women were older (62.3 ± 10.2 vs 57.8 ± 12.8, p = 0.01). As for the assessment of CAD extent, the HT+ individuals of both genders had significant CAD, although multivessel disease is more frequent in HT + men. The regression analysis for significant CAD showed that age and male gender were the determinant factors of multivessel disease and CS ≥ 100. Plaque type analysis showed that SAH was a predictive risk factor for partially calcified plaques (OR = 3.9). Conclusion Hypertensive men had multivessel disease more often than women. Male gender was a determinant factor of significant CAD, multivessel disease, CS ≥ 100 and calcified and partially calcified plaques, whereas SAH was predictive of partially calcified plaques. PMID:25861034

  13. Usefulness of computed tomography angiography for the detection of high-risk aortas for carotid artery stenting

    International Nuclear Information System (INIS)

    Yamamoto, Hiromichi; Kuwayama, Naoya; Hayashi, Nakamasa; Kubo, Michiya; Endo, Shunro

    2011-01-01

    This study evaluated the usefulness of computed tomography (CT) angiography for the detection of high-risk aortas for carotid artery stenting (CAS). We investigated changes in the treatment method and modifications of endovascular techniques according to the information from CT angiography. CT angiography using three-dimensional and multi-planar reconstruction was performed in 43 consecutive patients with carotid artery stenoses intended to undergo CAS. Two neurosurgeons evaluated the images and estimated the risk and difficulties of CAS. CT angiography clearly depicted the entire aorta, the supra-aortic vessels, and the ilio-femoral arteries in all patients. Abnormal vascular findings were found in 17 patients. High-risk aortic lesions for CAS were detected in 5 patients, including thick aortic plaques with thrombi in 2. We changed the treatment strategy from CAS to carotid endarterectomy (CEA) in these 2 patients. CT angiograms proved very useful in evaluating the approach routes of CAS in 12 patients. One patient had dissecting aneurysm of the thoracic aorta and another had aberrant right vertebral artery. In these two, the treatment strategy was changed from CAS to CEA. The treatment method was changed in 4 patients in total. CT angiography is useful for the detection of high-risk aortas for CAS and for the evaluation of safe approaches to the carotid artery. (author)

  14. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    International Nuclear Information System (INIS)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  15. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  16. Association between smoking habits and severity of coronary stenosis as assessed by coronary computed tomography angiography.

    Science.gov (United States)

    Yano, Masaya; Miura, Shin-Ichiro; Shiga, Yuhei; Miyase, Yuiko; Suematsu, Yasunori; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Nishikawa, Hiroaki; Saku, Keijiro

    2016-07-01

    Smoking promotes arteriosclerosis and is one of the most important coronary risk factors. However, few studies have investigated the association between smoking habits and the severity of coronary stenosis as assessed by coronary computed tomography angiography (CTA). We enrolled 416 patients [165/251 = smoker (past and current)/non-smoker)]. They had all undergone CTA and either were clinically suspected of having coronary artery disease (CAD) or had at least one cardiovascular risk factor. We divided the patients into smoking and non-smoking groups, and evaluated the presence of CAD, the number of significantly stenosed coronary vessels (VD), and the Gensini score as assessed by CTA in the two groups. The incidence of CAD, VD, the Gensini score, and coronary calcification score in the smoking group were all significantly greater than those in the non-smoking group (CAD, p = 0.009; VD, p = 0.003; Gensini score, p = 0.007; coronary calcification score, p = 0.01). Pack-year was significantly associated with VD and the Gensini score, and was strongly associated with multi-vessel disease (2- and 3-VD) (p < 0.05), whereas the duration of cessation in past smokers was not associated with VD or the Gensini score. Pack-year, but not the duration of cessation, may be the most important factor that was associated with the severity of coronary stenosis in terms of VD and the Gensini score.

  17. Intravenous digital subtraction angiography and helical computed tomography in evaluation of living renal donors

    International Nuclear Information System (INIS)

    Watarai, Yoshihiko; Usuki, Tomoaki; Takeuchi, Ichiro; Nonomura, Katsuya; Koyanagi, Tomohiko; Kubo, Kozo; Hirano, Tetsuo; Togashi, Masaki; Ohashi, Nobuo

    2001-01-01

    The present study was carried out to evaluate the accuracy of helical computed tomography (CT) and intravenous digital subtraction angiography (IV-DSA) on anatomical assessment of renal vasculature for living renal donors. Forty-two healthy potential renal donors were prospectively evaluated and 35 subsequently underwent donor nephrectomy after helical CT and IV-DSA evaluation. The vascular and non-vascular findings were compared between the findings on helical CT, IV-DSA and surgery. Ten prehilar branches and five accessory renal arteries were found at nephrectomy. Overall, operative findings agreed with the findings by IV-DSA in 89% and by helical CT in 83%. In delineating accessory arteries, IV-DSA had a sensitivity of 60% and specificity of 97%, whereas helical CT had a sensitivity of 40% and specificity of 100%. In delineating prehilar branches, IV-DSA had a sensitivity of 90% and specificity of 100%, whereas helical CT had a sensitivity of 70% and specificity of 100%. Accessory arteries and prehilar branches that were not detected by helical CT or IV-DSA, were less than 2 mm in diameter and did not require vascular reconstruction. Renal veins were delineated in 63% by IV-DSA, whereas they were clearly imaged by helical CT in all cases, including a case with a circumaortic renal vein. Non-vascular findings were obtained in 64% by helical CT, including two renal tumors. None of these findings were obtained by IV-DSA. Helical CT and IV-DSA provide comparably sufficient information on renal artery vasculature. However, helical CT provides significantly more information on venous and non-vascular findings as a single-imaging modality. (author)

  18. Ditection of coronary artery disease: accuracy of 64- slice computed tomography versus converntional invasive angiography

    Directory of Open Access Journals (Sweden)

    Taghizadeh M

    2008-11-01

    Full Text Available "nBackground: Multislice computed tomography (MSCT is a noninvasive method of detecting coronary artery disease (CAD. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT in daily practice, without patient selection. "nMethods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA. The CT system The mean time span between MSCT and QCA was 7.2±3.9 days. For the 64-MSCT, detection or exclusion of CAD, defined as one or more areas of >50% stenosis within major epicardial coronary arteries, the sensitivity, specificity, diagnostic accuracy, positive predictive value (PPV, and negative predictive value (NPV were evaluated both per patient and per segment. "nResults: Sixty-one of the 64 coronary CT angiograms (95% were of diagnostic image quality. QCA showed significant CAD in 64% (39/61 of the patients, with the other 36% (22/61 showing nonsignificant disease or no disease. Sensitivity, specificity, accuracy, PPV, and NPV of 64-MSCT per patient were 92%, 86%, 90%, 92% and 96%, respectively. By the per-segment analysis, 695 of 791 coronary artery segments were assessable (88%. Of these, 64-MSCT showed a sensitivity of 80%, specificity of 92%, accuracy of 90%, PPV of 65%, and NPV of 96%, respectively, in detecting CAD. "nConclusions: Both per patient and per segment analyses for coronary 64-MSCT showed a higher diagnostic accuracy than QCA. This suggests 64-MSCT should primarily be used for risk stratification on a per patient basis as a noninvasive gate-keeper diagnostic method.

  19. Estimation of radiation exposure of prospectively triggered 128-slice computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, D.; Fenchel, M.; Thomas, C.; Boehringer, N.; Tsiflikas, I.; Kaempf, M.; Syha, R.; Claussen, C.D.; Heuschmid, M. [Tuebingen Univ. (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Buchgeister, M. [Tuebingen Univ. (Germany). Medizinische Physik

    2010-12-15

    Purpose: To estimate the effective dose of prospectively triggered computed tomography coronary angiography (CTCA) in step-and-shoot (SAS) mode, depending on the tube current and tube voltage modulation. Materials and Methods: For dose measurements, an Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a 128-slice single source scanner providing a collimation of 128 x 0.6 mm and a rotation time of 0.38 seconds. CTCA in the SAS mode was acquired with variation of the tube current (160, 240, 320 mAs) and tube voltage (100, 120, 140 kV) at a simulated heart rate of 60 beats per minute and a scan range of 13.5 cm. Results: Depending on gender, tube current and tube voltage, the effective dose of a CTCA in SAS mode varies from 2.8 to 10.8 mSv. Due to breast tissue in the primary scan range, exposure in the case of females showed an increase of up to 60.0 {+-}.4 % compared to males. The dose reduction achieved by a reduction of tube current showed a significant positive, linear correlation to effective dose with a possible decrease in the effective dose of up to 60.4 % (r = 0.998; p = 0.044). Disproportionately high, the estimated effective dose can be reduced by using a lower tube voltage with a dose reduction of up to 52.4 %. Conclusion: Further substantial dose reduction of low-dose CTCA in SAS mode can be achieved by adapting the tube current and tube voltage and should be implemented in the clinical routine, i.e. adapting those protocol parameters to patient body weight. (orig.).

  20. Differences in coronary plaque composition with aging measured by coronary computed tomography angiography.

    Science.gov (United States)

    Tota-Maharaj, Rajesh; Blaha, Michael J; Rivera, Juan J; Henry, Travis S; Choi, Eue-Keun; Chang, Sung-A; Yoon, Yeonyee E; Chun, Eun Ju; Choi, Sang-Il; Blumenthal, Roger S; Chang, Hyuk-Jae; Nasir, Khurram

    2012-07-12

    Little is known about the independent impact of aging on coronary plaque morphology and composition in the era of cardiac computed tomography angiography (CCTA). We studied 1015 consecutive asymptomatic South Korean subjects (49 ± 10 years, 64% men) who underwent 64-slice CCTA during routine health evaluation. Coronary plaque characteristics were analyzed on a per-segment basis according to the modified AHA classification. Plaques with >50% calcified tissue were classified as calcified (CAP), plaques with NCAP). Multiple regression analysis was employed to describe the cross-sectional association between age tertile and plaque type burden (≥ 2 affected segments) after adjustment for other cardiovascular risk factors. The prevalence of coronary plaque increased with age, (1st tertile: 7.5%, 3rd tertile: 38.5% [pNCAP to overall plaque burden decreased with age from nearly 50% in the first tertile to approximately 20% in the third, while there was a reciprocal increase in both MCAP and CAP subtypes. In multivariable analysis, patients in the oldest tertile had a 2.5-fold increase in burden of NCAP, yet a nearly 40-fold increase in MCAP and 16-fold increase in CAP compared to the youngest tertile. In conclusion, CCTA is an effective method for measuring age-related differences in the burden of individual coronary plaque subtypes. Future research is needed to determine whether the increase in mixed and calcified plaques seen with aging produce an independent contribution to the age-related increase in cardiovascular risk. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Factors associated with coronary artery disease progression assessed by serial coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Camargo, Gabriel Cordeiro; Gottlieb, Ilan; Rothstein, Tamara; Derenne, Maria Eduarda; Sabioni, Leticia; Lima, Ronaldo de Souza Leão; Lima, João A. C.

    2017-01-01

    Background: Coronary computed tomography angiography (CCTA) allows for noninvasive coronary artery disease (CAD) phenotyping. Factors related to CAD progression are epidemiologically valuable. Objective: To identify factors associated with CAD progression in patients undergoing sequential CCTA testing. Methods: We retrospectively analyzed 384 consecutive patients who had at least two CCTA studies between December 2005 and March 2013. Due to limitations in the quantification of CAD progression, we excluded patients who had undergone surgical revascularization previously or percutaneous coronary intervention (PCI) between studies. CAD progression was defined as any increase in the adapted segment stenosis score (calculated using the number of diseased segments and stenosis severity) in all coronary segments without stent (in-stent restenosis was excluded from the analysis). Stepwise logistic regression was used to assess variables associated with CAD progression. Results: From a final population of 234 patients, a total of 117 (50%) had CAD progression. In a model accounting for major CAD risk factors and other baseline characteristics, only age (odds ratio [OR] 1.04, 95% confidence interval [95%CI] 1.01–1.07), interstudy interval (OR 1.03, 95%CI 1.01–1.04), and past PCI (OR 3.66, 95%CI 1.77–7.55) showed an independent relationship with CAD progression. Conclusions: A history of PCI with stent placement was independently associated with a 3.7-fold increase in the odds of CAD progression, excluding in-stent restenosis. Age and interstudy interval were also independent predictors of progression. (author)

  2. "No zone" approach in penetrating neck trauma reduces unnecessary computed tomography angiography and negative explorations.

    Science.gov (United States)

    Ibraheem, Kareem; Khan, Muhammad; Rhee, Peter; Azim, Asad; O'Keeffe, Terence; Tang, Andrew; Kulvatunyou, Narong; Joseph, Bellal

    2018-01-01

    The most recent management guidelines advocate computed tomography angiography (CTA) for any suspected vascular or aero-digestive injuries in all zones and give zone II injuries special consideration. We hypothesized that physical examination can safely guide CTA use in a "no zone" approach. An 8-year retrospective analysis of all adult trauma patients with penetrating neck trauma (PNT) was performed. We included all patients in whom the platysma was violated. Patients were classified into three groups as follows: hard signs, soft signs, and asymptomatic. CTA use, positive CTA (contrast extravasation, dissection, or intimal flap) and operative details were reported. Primary outcomes were positive CTA and therapeutic neck exploration (TNE) (defined by repair of major vascular or aero-digestive injuries). A total of 337 patients with PNT met the inclusion criteria. Eighty-two patients had hard signs and all of them went to the operating room, of which 59 (72%) had TNE. One hundred fifty-six patients had soft signs, of which CTA was performed in 121 (78%), with positive findings in 12 (10%) patients. The remaining 35 (22%) underwent initial neck exploration, of which 14 (40%) were therapeutic yielding a high rate of negative exploration. Ninty-nine patients were asymptomatic, of which CTA was performed in 79 (80%), with positive findings in 3 (4%), however, none of these patients required TNE. On sub analysis based on symptoms, there was no difference in the rate of TNE between the neck zones in patients with hard signs (P = 0.23) or soft signs (P = 0.51). Regardless of the zone of injury, asymptomatic patients did not require a TNE. Physical examination regardless of the zone of injury should be the primary guide to CTA or TNE in patients with PNT. Following traditional zone-based guidelines can result in unnecessary negative explorations in patients with soft signs and may need rethinking. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Characteristic detected on computed tomography angiography predict coronary artery plaque progression in non-culprit lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Ya Hang; Zhou, Jia Zhou; Zhou, Ying; Yang, Xiaobo; Yang, Jun Jie; Chen, Yun Dai [Dept. of Cardiology, Chinese PLA General Hospital, Beijing (China)

    2017-06-15

    This study sought to determine whether variables detected on coronary computed tomography angiography (CCTA) would predict plaque progression in non-culprit lesions (NCL). In this single-center trial, we analyzed 103 consecutive patients who were undergoing CCTA and percutaneous coronary intervention (PCI) for culprit lesions. Follow-up CCTA was scheduled 12 months after the PCI, and all patients were followed for 3 years after their second CCTA examination. High-risk plaque features and epicardial adipose tissue (EAT) volume were assessed by CCTA. Each NCL stenosis grade was compared visually between two CCTA scans to detect plaque progression, and patients were stratified into two groups based on this. Logistic regression analysis was used to evaluate the factors that were independently associated with plaque progression in NCLs. Time-to-event curves were compared using the log-rank statistic. Overall, 34 of 103 patients exhibited NCL plaque progression (33%). Logistic regression analyses showed that the NCL progression was associated with a history of ST-elevated myocardial infarction (odds ratio [OR] = 5.855, 95% confidence interval [CI] = 1.391–24.635, p = 0.016), follow-up low-density lipoprotein cholesterol level (OR = 6.832, 95% CI = 2.103–22.200, p = 0.001), baseline low-attenuation plaque (OR = 7.311, 95% CI = 1.242–43.028, p = 0.028) and EAT (OR = 1.015, 95% CI = 1.000–1.029, p = 0.044). Following the second CCTA examination, major adverse cardiac events (MACEs) were observed in 12 patients, and NCL plaque progression was significantly associated with future MACEs (log rank p = 0.006). Noninvasive assessment of NCLs by CCTA has potential prognostic value.

  4. Factors associated with coronary artery disease progression assessed by serial coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Gabriel Cordeiro; Gottlieb, Ilan, E-mail: ilangottlieb@gmail.com [Casa de Saúde São José, Rio de Janeiro, RJ (Brazil); Rothstein, Tamara; Derenne, Maria Eduarda; Sabioni, Leticia; Lima, Ronaldo de Souza Leão [Centro de Diagnóstico por Imagem CDPI, Rio de Janeiro, RJ (Brazil); Lima, João A. C. [Johns Hopkins University, Baltimore (United States)

    2017-05-15

    Background: Coronary computed tomography angiography (CCTA) allows for noninvasive coronary artery disease (CAD) phenotyping. Factors related to CAD progression are epidemiologically valuable. Objective: To identify factors associated with CAD progression in patients undergoing sequential CCTA testing. Methods: We retrospectively analyzed 384 consecutive patients who had at least two CCTA studies between December 2005 and March 2013. Due to limitations in the quantification of CAD progression, we excluded patients who had undergone surgical revascularization previously or percutaneous coronary intervention (PCI) between studies. CAD progression was defined as any increase in the adapted segment stenosis score (calculated using the number of diseased segments and stenosis severity) in all coronary segments without stent (in-stent restenosis was excluded from the analysis). Stepwise logistic regression was used to assess variables associated with CAD progression. Results: From a final population of 234 patients, a total of 117 (50%) had CAD progression. In a model accounting for major CAD risk factors and other baseline characteristics, only age (odds ratio [OR] 1.04, 95% confidence interval [95%CI] 1.01–1.07), interstudy interval (OR 1.03, 95%CI 1.01–1.04), and past PCI (OR 3.66, 95%CI 1.77–7.55) showed an independent relationship with CAD progression. Conclusions: A history of PCI with stent placement was independently associated with a 3.7-fold increase in the odds of CAD progression, excluding in-stent restenosis. Age and interstudy interval were also independent predictors of progression. (author)

  5. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Laspas, Fotios; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John; Tsantioti, Dimitra

    2011-01-01

    Background: Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. Purpose: To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Material and Methods: Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Results: Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR =65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Conclusion: Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure

  6. Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Helle Precht

    2016-12-01

    Full Text Available Background Coronary computed tomography angiography (CCTA requires high spatial and temporal resolution, increased low contrast resolution for the assessment of coronary artery stenosis, plaque detection, and/or non-coronary pathology. Therefore, new reconstruction algorithms, particularly iterative reconstruction (IR techniques, have been developed in an attempt to improve image quality with no cost in radiation exposure. Purpose To evaluate whether adaptive statistical iterative reconstruction (ASIR enhances perceived image quality in CCTA compared to filtered back projection (FBP. Material and Methods Thirty patients underwent CCTA due to suspected coronary artery disease. Images were reconstructed using FBP, 30% ASIR, and 60% ASIR. Ninety image sets were evaluated by five observers using the subjective visual grading analysis (VGA and assessed by proportional odds modeling. Objective quality assessment (contrast, noise, and the contrast-to-noise ratio [CNR] was analyzed with linear mixed effects modeling on log-transformed data. The need for ethical approval was waived by the local ethics committee as the study only involved anonymously collected clinical data. Results VGA showed significant improvements in sharpness by comparing FBP with ASIR, resulting in odds ratios of 1.54 for 30% ASIR and 1.89 for 60% ASIR (P = 0.004. The objective measures showed significant differences between FBP and 60% ASIR (P < 0.0001 for noise, with an estimated ratio of 0.82, and for CNR, with an estimated ratio of 1.26. Conclusion ASIR improved the subjective image quality of parameter sharpness and, objectively, reduced noise and increased CNR.

  7. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    International Nuclear Information System (INIS)

    Moore, R.K.G.; Sampson, C.; MacDonald, S.; Moynahan, C.; Groves, D.; Chester, M.R.

    2005-01-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor

  8. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    Energy Technology Data Exchange (ETDEWEB)

    Moore, R.K.G. [Cardiothoracic Centre, Liverpool (United Kingdom)]. E-mail: moore@roger.go-legend.net; Sampson, C. [Cardiothoracic Centre, Liverpool (United Kingdom); MacDonald, S. [Cardiothoracic Centre, Liverpool (United Kingdom); Moynahan, C. [Cardiothoracic Centre, Liverpool (United Kingdom); Groves, D. [National Refractory Angina Centre, Liverpool (United Kingdom); Chester, M.R. [National Refractory Angina Centre, Liverpool (United Kingdom)

    2005-09-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.

  9. Prospectively electrocardiogram-triggered high-pitch spiral acquisition coronary computed tomography angiography for assessment of biodegradable vascular scaffold expansion: Comparison with optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    D’Alfonso, Maria Grazia [Interventional Cardiology Unit University Of Florence, Heart and Vessels department, AOU Careggi, Florence (Italy); Mattesini, Alessio, E-mail: amattesini@gmail.com [Interventional Cardiology Unit University Of Florence, Heart and Vessels department, AOU Careggi, Florence (Italy); Meucci, Francesco [Interventional Cardiology Unit University Of Florence, Heart and Vessels department, AOU Careggi, Florence (Italy); Acquafresca, Manlio [Radiology Unit 4, Radiology Department, AOU Careggi, Florence (Italy); Gensini, Gian Franco; Valente, Serafina [Interventional Cardiology Unit University Of Florence, Heart and Vessels department, AOU Careggi, Florence (Italy)

    2014-11-15

    BVS polymeric struts are transparent to the light so that the vessel wall contour can be easily visualized using optical coherence tomography (OCT). Therefore OCT represents a unique tool for both the evaluation of the resorption process and for the assessment of acute BVS mechanical failure. Similarly, the metal-free struts allow unrestricted coronary computed tomography angiography (CCTA), thus this non invasive method might become the gold standard for a non invasive assessment of BVS. In this case we show the ability of CCTA, performed with a low X-Ray dose, to provide a good evaluation of scaffold expansion. The quantitative measurements were in agreement with those obtained with OCT.

  10. A comparison of standard radiological examinations, computed tomography, scintigraphy and angiography in the recidivistic diagnostic of bone tumors

    International Nuclear Information System (INIS)

    Schaeffer, G.

    1986-01-01

    In a retrospective study the diagnostic efficiency of standard radiography, computed tomography (CT), bone scintigraphy and angiography in the diagnosis of tumor recidivism was studied using 54 patients with an operatively treated bone tumor. The highest diagnostic sensitivity (100%) was achieved with the help of CT. For the determination or exclusion of a recidivistic bone tumor, the diagnostic strength of the individual procedures lies in their combinations, but these combinations should be made on the basis of the tumor type and disease. (MBC) [de

  11. Computed tomography angiography spot sign predicts intraprocedural aneurysm rupture in subarachnoid hemorrhage.

    Science.gov (United States)

    Burkhardt, Jan-Karl; Neidert, Marian Christoph; Stienen, Martin Nikolaus; Schöni, Daniel; Fung, Christian; Roethlisberger, Michel; Corniola, Marco Vincenzo; Bervini, David; Maduri, Rodolfo; Valsecchi, Daniele; Tok, Sina; Schatlo, Bawarjan; Bijlenga, Philippe; Schaller, Karl; Bozinov, Oliver; Regli, Luca

    2017-07-01

    To analyze whether the computed tomography angiography (CTA) spot sign predicts the intraprocedural rupture rate and outcome in patients with aneurysmal subarachnoid hemorrhage (aSAH). From a prospective nationwide multicenter registry database, 1023 patients with aneurysmal subarachnoid hemorrhage (aSAH) were analyzed retrospectively. Descriptive statistics and logistic regression analysis were used to compare spot sign-positive and -negative patients with aneurysmal intracerebral hemorrhage (aICH) for baseline characteristics, aneurysmal and ICH imaging characteristics, treatment and admission status as well as outcome at discharge and 1-year follow-up (1YFU) using the modified Rankin Scale (mRS). A total of 218 out of 1023 aSAH patients (21%) presented with aICH including 23/218 (11%) patients with spot sign. Baseline characteristics were comparable between spot sign-positive and -negative patients. There was a higher clip-to-coil ratio in patients with than without aICH (both spot sign positive and negative). Median aICH volume was significantly higher in the spot sign-positive group (50 ml, 13-223 ml) than in the spot sign-negative group (18 ml, 1-416; p spot sign-positive aICH thus were three times as likely as those with spot sign-negative aICH to show an intraoperative aneurysm rupture [odds ratio (OR) 3.04, 95% confidence interval (CI) 1.04-8.92, p = 0.046]. Spot sign-positive aICH patients showed a significantly worse mRS at discharge (p = 0.039) than patients with spot sign-negative aICH (median mRS 5 vs. 4). Logistic regression analysis showed that the spot sign was an aICH volume-dependent predictor for outcome. Both spot sign-positive and -negative aICH patients showed comparable rates of hospital death, death at 1YFU and mRS at 1YFU. In this multicenter data analysis, patients with spot sign-positive aICH showed higher aICH volumes and a higher rate of intraprocedural aneurysm rupture, but comparable long-term outcome to spot sign

  12. Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography: A Systematic Preclinical Approach.

    Science.gov (United States)

    Fleischmann, Ulrike; Pietsch, Hubertus; Korporaal, Johannes G; Flohr, Thomas G; Uder, Michael; Jost, Gregor; Lell, Michael M

    2018-05-01

    Low peak kilovoltage (kVp) protocols in computed tomography angiography (CTA) demand a review of contrast media (CM) administration practices. The aim of this study was to systematically evaluate different iodine concentrations of CM in a porcine model. Dynamic 70 kVp CTA was performed on 7 pigs using a third-generation dual-source CT system. Three CM injection protocols (A-C) with an identical total iodine dose and iodine delivery rate (150 mg I/kg, 12 s, 0.75 g I/s) differed in iodine concentration and flow rate (protocol A: 400 mg I/mL, 1.9 mL/s; B: 300 mg I/mL, 2.5 mL/s; C: 150 mg I/mL, 5 mL/s). All protocols were applied in a randomized order and compared intraindividually. Arterial enhancement at different locations in the pulmonary artery, the aorta, and aortic branches was measured over time. Time attenuation curves, peak enhancement, time to peak, and bolus tracking delay times needed for static CTA were calculated. The reproducibility of optimal parameters was tested in single-phase CTA. The heart rates of the pigs were comparable for all protocols (P > 0.7). The injection pressure was significantly higher for protocol A (64 ± 5 psi) and protocol C (55 ± 3 psi) compared with protocol B (39 ± 2 psi) (P < 0.001). Average arterial peak enhancement in the dynamic scans was 359 ± 51 HU (protocol A), 382 ± 36 HU (B), and 382 ± 60 HU (C) (A compared with B and C: P < 0.01; B compared with C: P = 0.995). Time to peak enhancement decreased with increasing injection rate. The delay time for bolus tracking depended on the injection rate as well and was highest for protocol A (4.7 seconds) and lowest for protocol C (3.9 seconds) (P = 0.038). The peak enhancement values of the dynamic scans highly correlated with those of the single-phase CTA scans. In 70 kVp CTA, 300 mg I/mL iodine concentrations showed to be superior to high-concentration CM when keeping the iodine delivery rate constant. Besides, iodine concentrations as low as 150 mg I/mL can be administered

  13. Coronary Plaque Volume and Composition Assessed by Computed Tomography Angiography in Patients With Late-Onset Major Depression

    DEFF Research Database (Denmark)

    Devantier, Torben Albert; Nørgaard, Bjarne Linde; Ovrehus, Kristian Altern

    2013-01-01

    Background: Depression is a stronger predictor for the onset of or death from clinical coronary artery disease than traditional cardiovascular risk factors. The association between depression and coronary artery disease has previously been investigated in non-contrast enhanced computed tomography...... studies with conflicting results. The aim of this study was to further elucidate the depression-coronary artery disease relation by use of coronary computed tomography angiography. Methods: The calcified and noncalcified coronary plaque volumes were determined by semiautomatic volumetric quantification...... with controls (14% vs. 7%, p = 0.044). Correspondingly, having depression was associated with an increased calcified plaque proportion of 11.3 [95% confidence interval: 2.63-20.1; p = 0.012] percentage points after adjustment for demographics and cardiovascular risk factors. Conclusion: The proportion...

  14. The increased use of computed tomography angiography and magnetic resonance angiography as the sole imaging modalities prior to infrainguinal bypass has had no effect on outcomes.

    Science.gov (United States)

    Shue, Bing; Damle, Rachelle N; Flahive, Julie; Kalish, Jeffrey A; Stone, David H; Patel, Virendra I; Schanzer, Andres; Baril, Donald T

    2015-08-01

    Angiography remains the gold standard imaging modality before infrainguinal bypass. Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) have emerged as noninvasive alternatives for preoperative imaging. We sought to examine contemporary trends in the utilization of CTA and MRA as isolated imaging modalities before infrainguinal bypass and to compare outcomes following infrainguinal bypass in patients who underwent CTA or MRA versus those who underwent conventional arteriography. Patients undergoing infrainguinal bypass within the Vascular Study Group of New England were identified (2003-2012). Patients were stratified by preoperative imaging modality: CTA/MRA alone or conventional angiography. Trends in utilization of these modalities were examined and demographics of these groups were compared. Primary end points included primary patency, secondary patency, and major adverse limb events (MALE) at 1 year as determined by Kaplan-Meier analysis. Multivariable Cox proportional hazards models were constructed to evaluate the effect of imaging modality on primary patency, secondary patency, and MALE after adjusting for confounders. In 3123 infrainguinal bypasses, CTA/MRA alone was used in 462 cases (15%) and angiography was used in 2661 cases (85%). Use of CTA/MRA alone increased over time, with 52 (11%) bypasses performed between 2003 and 2005, 189 (41%) bypasses performed between 2006 and 2009, and 221 (48%) bypasses performed between 2010 and 2012 (P < 0.001). Patients with CTA/MRA alone, compared with patients with angiography, more frequently underwent bypass for claudication (33% vs. 26%, P = 0.001) or acute limb ischemia (13% vs. 5%, P < 0.0001), more frequently had prosthetic conduits (39% vs. 30%, P = 0.001), and less frequently had tibial/pedal targets (32% vs. 40%, P = 0.002). After adjusting for these and other confounders, multivariable analysis demonstrated that the use of CTA/MRA alone was not associated with a significant

  15. Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography.

    Science.gov (United States)

    Lee, Ji Won; Lee, Geewon; Lee, Nam Kyung; Moon, Jin Il; Ju, Yun Hye; Suh, Young Ju; Jeong, Yeon Joo

    2016-01-01

    The aim of the study was to assess the effectiveness of the adaptive statistical iterative reconstruction (ASIR) for dual-energy computed tomography pulmonary angiography (DE-CTPA) with a reduced iodine load. One hundred forty patients referred for chest CT were randomly divided into a DE-CTPA group with a reduced iodine load or a standard CTPA group. Quantitative and qualitative image qualities of virtual monochromatic spectral (VMS) images with filtered back projection (VMS-FBP) and those with 50% ASIR (VMS-ASIR) in the DE-CTPA group were compared. Image qualities of VMS-ASIR images in the DE-CTPA group and ASIR images in the standard CTPA group were also compared. All quantitative and qualitative indices, except attenuation value of pulmonary artery in the VMS-ASIR subgroup, were superior to those in the VMS-FBP subgroup (all P ASIR images were superior to those of ASIR images in the standard CTPA group (P ASIR images of the DE-CTPA group than in ASIR images of the standard CTPA group (P = 0.001). The ASIR technique tends to improve the image quality of VMS imaging. Dual-energy computed tomography pulmonary angiography with ASIR can reduce contrast medium volume and produce images of comparable quality with those of standard CTPA.

  16. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  17. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2006-01-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA).Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far. (author)

  18. Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time

    International Nuclear Information System (INIS)

    Zhang, Shi-Zheng; Hu, Xiu-Hua; Zhang, Qiao-Wei; Huang, Wen-Xin

    2005-01-01

    The aim of our study is to evaluate computed tomography (CT) coronary angiography in patients with a high heart rate using 16-slice spiral CT with 0.37-s gantry rotation time. We compare the image quality of patients whose heart rates were over 70 beats per minute (bpm) with that of patients whose heart rates were 70 bpm or less. Sixty patients with various heart rates underwent retrospectively ECG-gated multislice spiral CT (MSCT) coronary angiography. Two experienced observers who were blind to the heart rates of the patients evaluated all the MSCT coronary angiographic images and calculated the assessable segments. A total of 620 out of 891 (69.6%) segments were satisfactorily visualized. On average, 10.3 coronary artery segments per patient could be evaluated. In 36 patients whose heart rates were below 70 bpm [mean 62.2 bpm±5.32 (standard deviation, SD)], the number of assessable segments was 10.72±2.02 (SD). In the other 24 patients whose heart rates were above 70 bpm [mean 78.6 bpm±8.24 (SD)], the corresponding number was 9.75±1.74 (SD). No statistically significant difference was found in these two subgroups' t test, P>0.05. The new generation of 16-slice spiral CT with 0.37-s rotation time can satisfactorily evaluate the coronary arteries of patients with high heart rates (above 70 bpm, up to 102 bpm). (orig.)

  19. Prevalence of extra-cardiac findings on studies of noninvasive coronary angiography multidetector computed tomography 64 rows

    International Nuclear Information System (INIS)

    Carrascosa, Patricia M.; Capunay, Carlos M.; Deviggiano, A.; Melendez, F.; Carrascosa, Jorge M.; Garcia, M.

    2007-01-01

    The aim of this paper is to show the importance of evaluating in a full form images obtained from a studio of noninvasive coronary angiography by multidetector computed tomography (AC-TCMD). 90 users of AC-TCMD were evaluated retrospectively conducted between October 2006 and April 2007 with a multidetector tomography of 64-rows(Phillips Medical Systems) . The images were reprocessed with a maximum field of vision and determined the presence of extra-cardiac findings, which were classified according to their impact on the management and treatment of patient at 3 degrees: low, medium and high grade. The studies were assessed jointly by a cardiologist and a radiologist qualified for cardiac and corporal evaluation. Extra-cardiac findings were identified in 58 patients. There were 38 patients with findings of low grade, 31 medium grade and 1 high grade. It was recommended to 16 patients its monitoring by images on reasonable period of time [es

  20. Anatomical variants of celiac trunk, hepatic and renal arteries in a population of developing country using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Arifuzzaman, M.; Naqvi, S.S.N.; Rasool, M.; Hussain, M.

    2017-01-01

    Background: Multidetector Computed Tomography (MDCT)s has become a major part in evaluation of hepatic and renal tumours. With improvements in MDCT, CT angiography has also improved and normal anatomy and its variants in patients undergoing operative or interventional procedures can be effectively studied. The purpose of this study was to evaluate the frequency of anatomical variation of celiac trunk, hepatic and renal arterial systems in patients undergoing multidetector CT (MDCT) angiography of the abdominal aorta. Methods: A descriptive, retrospective cross-sectional study was carried out on CT angiographies performed during the months of October till December 2015. Hepatic and renal arteries and celiac trunk were studied and normal and anatomical variations were noted. All patients with abnormalities affecting the vessels or a history of any vascular abnormality were excluded from the study. Results: Out of total 110 patients, 69.1% had normal and 30.9% had variant hepatic artery with Michel Type IV being the most common variant whereas 88.2% had normal celiac trunk and 8.2% had gastrosplenic trunk variant. Variation in renal arterial system was observed in 15.5% of the patients with two renal arteries on right and two on left being the most common type. Multiple variants were identified in 11.8% of the patients. Conclusion: The type and knowledge of anatomy is of prime importance for an optimum preoperative planning in surgical or radiological procedure. MDCT allows minimally invasive assessment of arterial anatomy with high quality 3D reconstruction images. (author)

  1. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.

    Science.gov (United States)

    Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T

    2013-12-01

    Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  3. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  4. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  5. Sensitivity of computer assisted radionuclide angiography in transient ischemic attack and prolonged reversible ischemic neurological deficit. Comparison with findings in radiographic angiography and transmission computerized axial tomography

    International Nuclear Information System (INIS)

    Buell, U.; Scheid, K.F.; Lanksch, W.; Kleinhans, E.; Ulbert, V.; Reger, U.; Rath, M.; Moser, E.A.

    1981-01-01

    Computer assisted radionuclide angiography (CARNA) with 99mTc-DTPA was employed to study 143 patients with transient ischemic attacks (TIA) and 79 patients with prolonged reversible ischemic neurologic deficit (PRIND). The results of CARNA were compared with findings from radiographic angiography (RGA) in 173 patients and with findings in transmission computerized axial tomography (T-CAT) in 154 patients. In patients with TIA, CARNA showed a hemispherical perfusion deficit in 74.8%, and with PRIND 87.3%. This deficit, determined as the relative difference between the involved and the non-involved hemisphere, was significantly (p less than 0.0025) greater in PRIND (minus 23%) than in TIA (minus 17%). Sensitivity of CARNA was independent of the interval from ictus to examination for more than 4 months. RGA in TIA revealed true positives in 82.0%, in PRIND it was 89.5%. T-CAT was positive in TIA in only 16.8% but in PRIND it was 64.4%. Combined sensitivities in TIA (92.4%) and in PRIND (94.0%) were highest with the combination of CARNA and RGA. However, in PRIND the combination of non-invasive methods (CARNA and T-CAT) revealed 93.2% positive findings. Combinations of these evaluation methods may be used to detect cerebrovascular disease in patients with such dysfunction

  6. Diagnostic accuracy of computer tomography angiography and magnetic resonance angiography in the stenosis detection of autologuous hemodialysis access: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Bin Li

    Full Text Available PURPOSE: To compare the diagnostic performances of computer tomography angiography (CTA and magnetic resonance angiography (MRA for detection and assessment of stenosis in patients with autologuous hemodialysis access. MATERIALS AND METHODS: Search of PubMed, MEDLINE, EMBASE and Cochrane Library database from January 1984 to May 2013 for studies comparing CTA or MRA with DSA or surgery for autologuous hemodialysis access. Eligible studies were in English language, aimed to detect more than 50% stenosis or occlusion of autologuous vascular access in hemodialysis patients with CTA and MRA technology and provided sufficient data about diagnosis performance. Methodological quality was assessed by the Quality Assessment of Diagnostic Studies (QUADAS instrument. Sensitivities (SEN, specificities (SPE, positive likelihood ratio (PLR, negative likelihood values (NLR, diagnostic odds ratio (DOR and areas under the receiver operator characteristic curve (AUC were pooled statistically. Potential threshold effect, heterogeneity and publication bias was evaluated. The clinical utility of CTA and MRA in detection of stenosis was also investigated. RESULT: Sixteen eligible studies were included, with a total of 500 patients. Both CTA and MRA were accurate modality (sensitivity, 96.2% and 95.4%, respectively; specificity, 97.1 and 96.1%, respectively; DOR [diagnostic odds ratio], 393.69 and 211.47, respectively for hemodialysis vascular access. No significant difference was detected between the diagnostic performance of CTA (AUC, 0.988 and MRA (AUC, 0.982. Meta-regression analyses and subgroup analyses revealed no statistical difference. The Deek's funnel plots suggested a publication bias. CONCLUSION: Diagnostic performance of CTA and MRA for detecting stenosis of hemodialysis vascular access had no statistical difference. Both techniques may function as an alternative or an important complement to conventional digital subtraction angiography (DSA and may be

  7. Analysis of Complex Coronary Plaque in Multidetector Computed Tomography: Comparison with Conventional Coronary Angiography

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Bang, Duck Won; Cho, Yoon Haeng; Suk, Eun Ha

    2011-01-01

    To delineate complex plaque morphology in patients with stable angina using coronary computed tomographic angiography (CTA). 36 patients with complex plaques proven by conventional coronary angiography (CAG), who had taken CTA for evaluation of typical angina, were enrolled in this study. Intravascular ultrasonography (IVUS) was performed in 14 patients (16 lesions). We compared CTA with CAG for plaque features and analyzed vascular cutoff, intraluminal filling defect in a patent vessel, irregularity of plaque, and ulceration. Also, the density of plaque was evaluated on CTA. CAG and CTA showed complex morphology in 44 cases (100%) and 34 cases, (77%), respectively, with features including abrupt vessel cutoff (27 vs. 16%, κ=0.57), intraluminal filling defect (32 vs. 30%, κ=0.77), irregularity (75 vs. 52%, κ=0.52), and ulceration (16 vs. 11%, κ=0.60). CTA indicated that the complex lesions were hypodense (mean 66 ± 21 Houndsfield Units). CTA is a very accurate and useful non-invasive imaging modality for evaluating complex plaque in patients with typical angina.

  8. Analysis of Complex Coronary Plaque in Multidetector Computed Tomography: Comparison with Conventional Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun [Dept. of Radiology, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Bang, Duck Won; Cho, Yoon Haeng [Dept. of Internal Medicine, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthyesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2011-04-15

    To delineate complex plaque morphology in patients with stable angina using coronary computed tomographic angiography (CTA). 36 patients with complex plaques proven by conventional coronary angiography (CAG), who had taken CTA for evaluation of typical angina, were enrolled in this study. Intravascular ultrasonography (IVUS) was performed in 14 patients (16 lesions). We compared CTA with CAG for plaque features and analyzed vascular cutoff, intraluminal filling defect in a patent vessel, irregularity of plaque, and ulceration. Also, the density of plaque was evaluated on CTA. CAG and CTA showed complex morphology in 44 cases (100%) and 34 cases, (77%), respectively, with features including abrupt vessel cutoff (27 vs. 16%, {kappa}=0.57), intraluminal filling defect (32 vs. 30%, {kappa}=0.77), irregularity (75 vs. 52%, {kappa}=0.52), and ulceration (16 vs. 11%, {kappa}=0.60). CTA indicated that the complex lesions were hypodense (mean 66 {+-} 21 Houndsfield Units). CTA is a very accurate and useful non-invasive imaging modality for evaluating complex plaque in patients with typical angina.

  9. Relationship Between Quantitative Adverse Plaque Features From Coronary Computed Tomography Angiography and Downstream Impaired Myocardial Flow Reserve by 13N-Ammonia Positron Emission Tomography: A Pilot Study.

    Science.gov (United States)

    Dey, Damini; Diaz Zamudio, Mariana; Schuhbaeck, Annika; Juarez Orozco, Luis Eduardo; Otaki, Yuka; Gransar, Heidi; Li, Debiao; Germano, Guido; Achenbach, Stephan; Berman, Daniel S; Meave, Aloha; Alexanderson, Erick; Slomka, Piotr J

    2015-10-01

    We investigated the relationship of quantitative plaque features from coronary computed tomography (CT) angiography and coronary vascular dysfunction by impaired myocardial flow reserve (MFR) by (13)N-Ammonia positron emission tomography (PET). Fifty-one patients (32 men, 62.4±9.5 years) underwent combined rest-stress (13)N-ammonia PET and CT angiography scans by hybrid PET/CT. Regional MFR was measured from PET. From CT angiography, 153 arteries were evaluated by semiautomated software, computing arterial noncalcified plaque (NCP), low-density NCP (NCP<30 HU), calcified and total plaque volumes, and corresponding plaque burden (plaque volumex100%/vessel volume), stenosis, remodeling index, contrast density difference (maximum difference in luminal attenuation per unit area in the lesion), and plaque length. Quantitative stenosis, plaque burden, and myocardial mass were combined by boosted ensemble machine-learning algorithm into a composite risk score to predict impaired MFR (MFR≤2.0) by PET in each artery. Nineteen patients had impaired regional MFR in at least 1 territory (41/153 vessels). Patients with impaired regional MFR had higher arterial NCP (32.4% versus 17.2%), low-density NCP (7% versus 4%), and total plaque burden (37% versus 19.3%, P<0.02). In multivariable analysis with 10-fold cross-validation, NCP burden was the most significant predictor of impaired MFR (odds ratio, 1.35; P=0.021 for all). For prediction of impaired MFR with 10-fold cross-validation, receiver operating characteristics area under the curve for the composite score was 0.83 (95% confidence interval, 0.79-0.91) greater than for quantitative stenosis (0.66, 95% confidence interval, 0.57-0.76, P=0.005). Compared with stenosis, arterial NCP burden and a composite score combining quantitative stenosis and plaque burden from CT angiography significantly improves identification of downstream regional vascular dysfunction. © 2015 American Heart Association, Inc.

  10. Morphological Analysis of Bronchial Arteries and Variants with Computed Tomography Angiography

    Directory of Open Access Journals (Sweden)

    Claudia Nallely Esparza-Hernández

    2017-01-01

    Full Text Available The aim of our study was to determine the prevalence of anatomical variants of bronchial arteries using computed tomographic angiography in a population of northeastern Mexico. An observational, transversal, descriptive, comparative, retrospective study was performed using 139 imaging studies of Mexican patients in which we evaluated the following parameters from the left and right bronchial arteries: artery origin, branching pattern, arterial ostium, vertebral level of origin, diameter, and mediastinal trajectory. The anatomies of the bronchial arteries were similar in both genders, except distribution for vertebral origin level (p  0.006 and the diameter (p  0.013. Left and right arteries were similar, except for the mediastinal trajectory in reference to the esophagus (p<0.001 as well as the arterial diameter (p<0.001 and lumen diameter.

  11. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  12. Ultrasonography, angiography, computed tomography and magnetic resonance in nodular regenerative hyperplasia of the liver

    International Nuclear Information System (INIS)

    Patriarche, C.; Pelletier, G.; Attali, P.; Ladouch-Badre, A.; Fabre, M.; Roche, A.; Etienne, J.P.

    1988-01-01

    Ultrasonographic, computed tomographic, and angiographic abnormalities of nodular regenerative hyperplasia have been described in very few cases. We report here the case of a 50-year-old man with round, well-limited hypoechogenic lesions involving the two lobes of the liver, and hypervascular, poorly delineated angiographic lesions. Computed tomography and magnetic resonance of the liver were normal. Histological examination of large liver specimens provided by intraoperative biopsy allowed the diagnosis of nodular regenerative hyperplasia. Such a pseudo-tumoral ultrasonographic and angiographic pattern must be recognized in order to avoid diagnostic and therapeutic mistakes, especially since percutaneous liver biopsy usually fails to diagnose this disease. (author)

  13. Diagnostic performance of computed tomography coronary angiography (from the Prospective National Multicenter Multivendor EVASCAN Study).

    Science.gov (United States)

    Gueret, Pascal; Deux, Jean-François; Bonello, Laurent; Sarran, Anthony; Tron, Christophe; Christiaens, Luc; Dacher, Jean-Nicolas; Bertrand, David; Leborgne, Laurent; Renard, Cedric; Caussin, Christophe; Cluzel, Philippe; Helft, Gerard; Crochet, Dominique; Vernhet-Kovacsik, Hélène; Chabbert, Valérie; Ferrari, Emile; Gilard, Martine; Willoteaux, Serge; Furber, Alain; Barone-Rochette, Gilles; Jankowski, Adrien; Douek, Philippe; Mousseaux, Elie; Sirol, Marc; Niarra, Ralph; Chatellier, Gilles; Laissy, Jean-Pierre

    2013-02-15

    Computed tomographic coronary angiography (CTCA) has been proposed as a noninvasive test for significant coronary artery disease (CAD), but only limited data are available from prospective multicenter trials. The goal of this study was to establish the diagnostic accuracy of CTCA compared to coronary angiography (CA) in a large population of symptomatic patients with clinical indications for coronary imaging. This national, multicenter study was designed to prospectively evaluate stable patients able to undergo CTCA followed by conventional CA. Data from CTCA and CA were analyzed in a blinded fashion at central core laboratories. The main outcome was the evaluation of patient-, vessel-, and segment-based diagnostic performance of CTCA to detect or rule out significant CAD (≥50% luminal diameter reduction). Of 757 patients enrolled, 746 (mean age 61 ± 12 years, 71% men) were analyzed. They underwent CTCA followed by CA 1.7 ± 0.8 days later using a 64-detector scanner. The prevalence of significant CAD in native coronary vessels by CA was 54%. The rate of nonassessable segments by CTCA was 6%. In a patient-based analysis, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of CTCA were 91%, 50%, 68%, 83%, 1.82, and 0.18, respectively. The strongest predictors of false-negative results on CTCA were high estimated pretest probability of CAD (odds ratio [OR] 1.97, p <0.001), male gender (OR 1.5, p <0.002), diabetes (OR 1.5, p <0.0001), and age (OR 1.2, p <0.0001). In conclusion, in this large multicenter study, CTCA identified significant CAD with high sensitivity. However, in routine clinical practice, each patient should be individually evaluated, and the pretest probability of obstructive CAD should be taken into account when deciding which method, CTCA or CA, to use to diagnose its presence and severity. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Combined diagnostic performance of coronary computed tomography angiography and computed tomography derived fractional flow reserve for the evaluation of myocardial ischemia: A meta-analysis.

    Science.gov (United States)

    Tan, Xiao Wei; Zheng, Qishi; Shi, Luming; Gao, Fei; Allen, John Carson; Coenen, Adriaan; Baumann, Stefan; Schoepf, U Joseph; Kassab, Ghassan S; Lim, Soo Teik; Wong, Aaron Sung Lung; Tan, Jack Wei Chieh; Yeo, Khung Keong; Chin, Chee Tang; Ho, Kay Woon; Tan, Swee Yaw; Chua, Terrance Siang Jin; Chan, Edwin Shih Yen; Tan, Ru San; Zhong, Liang

    2017-06-01

    To evaluate the combined diagnostic accuracy of coronary computed tomography angiography (CCTA) and computed tomography derived fractional flow reserve (FFRct) in patients with suspected or known coronary artery disease (CAD). PubMed, The Cochrane library, Embase and OpenGray were searched to identify studies comparing diagnostic accuracy of CCTA and FFRct. Diagnostic test measurements of FFRct were either extracted directly from the published papers or calculated from provided information. Bivariate models were conducted to synthesize the diagnostic performance of combined CCTA and FFRct at both "per-vessel" and "per-patient" levels. 7 articles were included for analysis. The combined diagnostic outcomes from "both positive" strategy, i.e. a subject was considered as "positive" only when both CCTA and FFRct were "positive", demonstrated relative high specificity (per-vessel: 0.91; per-patient: 0.81), high positive likelihood ratio (LR+, per-vessel: 7.93; per-patient: 4.26), high negative likelihood ratio (LR-, per-vessel: 0.30; per patient: 0.24) and high accuracy (per-vessel: 0.91; per-patient: 0.81) while "either positive" strategy, i.e. a subject was considered as "positive" when either CCTA or FFRct was "positive", demonstrated relative high sensitivity (per-vessel: 0.97; per-patient: 0.98), low LR+ (per-vessel: 1.50; per-patient: 1.17), low LR- (per-vessel: 0.07; per-patient: 0.09) and low accuracy (per-vessel: 0.57; per-patient: 0.54). "Both positive" strategy showed better diagnostic performance to rule in patients with non-significant stenosis compared to "either positive" strategy, as it efficiently reduces the proportion of testing false positive subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Prognostic value of absence or presence of coronary artery disease determined by 64-slice computed tomography coronary angiography A systematic review and meta-analysis

    DEFF Research Database (Denmark)

    Abdulla, Jawdat; Asferg, Camilla Lundegaard; Kofoed, Klaus Fuglsang

    2011-01-01

    To determine via a meta-analysis the prognostic value of 64-slice computed tomography angiography (CTA) by quantifying risk of major adverse cardiac events (MACE) in different patient groups classified according to CT angiographic findings. A systematic literature search and meta...

  16. Normal values of left ventricularmass and cardiac chamber volumes assessed by 320-detector computed tomography angiography in the Copenhagen General Population Study

    DEFF Research Database (Denmark)

    Fuchs, Andreas; Mejdahl, Mads Rams; Kühl, J Tobias

    2016-01-01

    Aims Normal values of left ventricular mass (LVM) and cardiac chamber sizes are prerequisites for the diagnosis of individuals with heart disease. LVM and cardiac chamber sizes may be recorded during cardiac computed tomography angiography (CCTA), and thus modality specific normal values are need...

  17. Effects on costs of frontline diagnostic evaluation in patients suspected of angina: coronary computed tomography angiography vs. conventional ischaemia testing

    DEFF Research Database (Denmark)

    Nielsen, Lene H; Olsen, Jens; Markenvard, John

    2013-01-01

    group. The mean (SD) total costs per patient at the end of thefollow-up were 14% lower in the CTA group than in the ex-test group, € 1510 (3474) vs. €1777 (3746) (P = 0.03). CONCLUSION: Diagnostic assessment of symptomatic patients with a low-intermediate probability of CAD by CTA incurred lower costs......AIMS: The aim of this study was to investigate in patients with stable angina the effects on costs of frontline diagnostics by exercise-stress testing (ex-test) vs. coronary computed tomography angiography (CTA). METHODS AND RESULTS: In two coronary units at Lillebaelt Hospital, Denmark, 498...... patients were identified in whom either ex-test (n = 247) or CTA (n = 251) were applied as the frontline diagnostic strategy in symptomatic patients with a low-intermediate pre-test probability of coronary artery disease (CAD). During 12 months of follow-up, death, myocardial infarction and costs...

  18. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  19. Intravenous coronary angiography by electron beam computed tomography : a clinical evaluation

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A; van Geuns, R J; van Ooijen, P; Oudkerk, M; de Feyter, P J

    1998-01-01

    BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold

  20. Impact of a New Adaptive Statistical Iterative Reconstruction (ASIR)-V Algorithm on Image Quality in Coronary Computed Tomography Angiography.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Baggiano, Andrea; Fazzari, Fabio; Mushtaq, Saima; Conte, Edoardo; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Verdecchia, Massimo; Campari, Alessandro; Martini, Chiara; Gatti, Marco; Fusini, Laura; Bonfanti, Lorenzo; Consiglio, Elisa; Rabbat, Mark G; Bartorelli, Antonio L; Pepi, Mauro

    2018-03-27

    A new postprocessing algorithm named adaptive statistical iterative reconstruction (ASIR)-V has been recently introduced. The aim of this article was to analyze the impact of ASIR-V algorithm on signal, noise, and image quality of coronary computed tomography angiography. Fifty consecutive patients underwent clinically indicated coronary computed tomography angiography (Revolution CT; GE Healthcare, Milwaukee, WI). Images were reconstructed using filtered back projection and ASIR-V 0%, and a combination of filtered back projection and ASIR-V 20%-80% and ASIR-V 100%. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for left main coronary artery (LM), left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA) and were compared between the different postprocessing algorithms used. Similarly a four-point Likert image quality score of coronary segments was graded for each dataset and compared. A cutoff value of P ASIR-V 0%, ASIR-V 100% demonstrated a significant reduction of image noise in all coronaries (P ASIR-V 0%, SNR was significantly higher with ASIR-V 60% in LM (P ASIR-V 0%, CNR for ASIR-V ≥60% was significantly improved in LM (P ASIR-V ≥80%. ASIR-V 60% had significantly better Likert image quality scores compared to ASIR-V 0% in segment-, vessel-, and patient-based analyses (P ASIR-V 60% provides the optimal balance between image noise, SNR, CNR, and image quality. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  2. Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pontone, Gianluca; Bertella, Erika; Baggiano, Andrea; Mushtaq, Saima; Loguercio, Monica; Segurini, Chiara; Conte, Edoardo; Beltrama, Virginia; Annoni, Andrea; Formenti, Alberto; Petulla, Maria; Trabattoni, Daniela; Pepi, Mauro [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Andreini, Daniele; Montorsi, Piero; Bartorelli, Antonio L. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); University of Milan, Department of Cardiovascular Sciences and Community Health, Milan (Italy); Guaricci, Andrea I. [University of Foggia, Department of Cardiology, Foggia (Italy)

    2016-01-15

    The aim of this study was to evaluate the impact of a novel intra-cycle motion correction algorithm (MCA) on overall evaluability and diagnostic accuracy of cardiac computed tomography coronary angiography (CCT). From a cohort of 900 consecutive patients referred for CCT for suspected coronary artery disease (CAD), we enrolled 160 (18 %) patients (mean age 65.3 ± 11.7 years, 101 male) with at least one coronary segment classified as non-evaluable for motion artefacts. The CCT data sets were evaluated using a standard reconstruction algorithm (SRA) and MCA and compared in terms of subjective image quality, evaluability and diagnostic accuracy. The mean heart rate during the examination was 68.3 ± 9.4 bpm. The MCA showed a higher Likert score (3.1 ± 0.9 vs. 2.5 ± 1.1, p < 0.001) and evaluability (94%vs.79 %, p < 0.001) than the SRA. In a 45-patient subgroup studied by clinically indicated invasive coronary angiography, specificity, positive predictive value and accuracy were higher in MCA vs. SRA in segment-based and vessel-based models, respectively (87%vs.73 %, 50%vs.34 %, 85%vs.73 %, p < 0.001 and 62%vs.28 %, 66%vs.51 % and 75%vs.57 %, p < 0.001). In a patient-based model, MCA showed higher accuracy vs. SCA (93%vs.76 %, p < 0.05). MCA can significantly improve subjective image quality, overall evaluability and diagnostic accuracy of CCT. (orig.)

  3. Electrocardiograph-gated single photon emission computed tomography radionuclide angiography presents good interstudy reproducibility for the quantification of global systolic right ventricular function.

    Science.gov (United States)

    Daou, Doumit; Coaguila, Carlos; Vilain, Didier

    2007-05-01

    Electrocardiograph-gated single photon emission computed tomography (SPECT) radionuclide angiography provides accurate measurement of right ventricular ejection fraction and end-diastolic and end-systolic volumes. In this study, we report the interstudy precision and reliability of SPECT radionuclide angiography for the measurement of global systolic right ventricular function using two, three-dimensional volume processing methods (SPECT-QBS, SPECT-35%). These were compared with equilibrium planar radionuclide angiography. Ten patients with chronic coronary artery disease having two SPECT and planar radionuclide angiography acquisitions were included. For the right ventricular ejection fraction, end-diastolic volume and end-systolic volume, the interstudy precision and reliability were better with SPECT-35% than with SPECT-QBS. The sample sizes needed to objectify a change in right ventricular volumes or ejection fraction were lower with SPECT-35% than with SPECT-QBS. The interstudy precision and reliability of SPECT-35% and SPECT-QBS for the right ventricle were better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography on the same population. SPECT-35% and SPECT-QBS present good interstudy precision and reliability for right ventricular function, with the results favouring the use of SPECT-35%. The results are better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography. They need to be confirmed in a larger population.

  4. Coronary computed tomography angiography using prospective electrocardiography-gated axial scans with 64-detector computed tomography. Evaluation of stair-step artifacts and padding time

    International Nuclear Information System (INIS)

    Kimura, Fumiko; Umezawa, Tatsuo; Asano, Tomonari; Chihara, Ruri; Nishi, Naoko; Nishimura, Shigeyoshi; Sakai, Fumikazu

    2010-01-01

    We compared stair-step artifacts and radiation dose between prospective electrocardiography (ECG)-gated coronary computed tomography angiography (prospective CCTA) and retrospective CCTA using 64-detector CT and determined the optimal padding time (PT) for prospective CCTA. We retrospectively evaluated 183 patients [mean heart rate (HR) <65 beats/min, maximum HR instability <5 beats/min] who had undergone CCTA. We scored stair-step artifacts from 1 (severe) to 5 (none) and evaluated the effective dose in 53 patients with retrospective CCTA and 130 with prospective CCTA (PT 200 ms, n=32; PT 50 ms, n=98). Mean artifact scores were 4.3 in both retrospective and prospective CCTAs. However, statistically more arteries scored <3 (nonassessable) on prospective CCTA (P<0.001). Mean scores for prospective CCTA with 200- and 50-ms PT were 4.1 and 4.3, respectively (no significant difference). The radiation dose of prospective CCTA was reduced by 59.1% to 80.7%. Prospective CCTA reduces the radiation dose and allows diagnostic imaging in most cases but shows more nonevaluable artifacts than retrospective CCTA. Use of 50-ms instead of 200-ms PT appears to maintain image quality in patients with a mean HR <65 beats/min and HR instability of <5 beats/min. (author)

  5. Denver screening protocol for blunt cerebrovascular injury reduces the use of multi-detector computed tomography angiography.

    Science.gov (United States)

    Beliaev, Andrei M; Barber, P Alan; Marshall, Roger J; Civil, Ian

    2014-06-01

    Blunt cerebrovascular injury (BCVI) occurs in 0.2-2.7% of blunt trauma patients and has up to 30% mortality. Conventional screening does not recognize up to 20% of BCVI patients. To improve diagnosis of BCVI, both an expanded battery of screening criteria and a multi-detector computed tomography angiography (CTA) have been suggested. The aim of this study is to investigate whether the use of CTA restricted to the Denver protocol screen-positive patients would reduce the unnecessary use of CTA as a pre-emptive screening tool. This is a registry-based study of blunt trauma patients admitted to Auckland City Hospital from 1998 to 2012. The diagnosis of BCVI was confirmed or excluded with CTA, magnetic resonance angiography and, if these imaging were non-conclusive, four-vessel digital subtraction angiography. Thirty (61%) BCVI and 19 (39%) non-BCVI patients met eligibility criteria. The Denver protocol applied to our cohort of patients had a sensitivity of 97% (95% confidence interval (CI): 83-100%) and a specificity of 42% (95% CI: 20-67%). With a prevalence of BCVI in blunt trauma patients of 0.2% and 2.7%, post-test odds of a screen-positive test were 0.03 (95% CI: 0.002-0.005) and 0.046 (95% CI: 0.314-0.068), respectively. Application of the CTA to the Denver protocol screen-positive trauma patients can decrease the use of CTA as a pre-emptive screening tool by 95-97% and reduces its hazards. © 2013 Royal Australasian College of Surgeons.

  6. Comparison of intra-aortic computed tomography angiography to conventional angiography in the presurgical visualization of the Adamkiewicz artery: first results in patients with thoracoabdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Clarencon, Frederic; Maria, Federico di; Cormier, Evelyne; Sourour, Nader; Gabrieli, Joseph; Iosif, Christina; Chiras, Jacques; Gaudric, Julien; Koskas, Fabien; Jenny, Catherine

    2013-01-01

    The aim of this study was to compare the sensitivity of intra-aortic computed tomography angiography (IA-CTA) to that of regular spinal digital subtraction angiography for the presurgical location of the Adamkiewicz artery (AKA). Thirty patients (21 males, 9 females; mean age 64 years) had an IA-CTA for the location of the AKA before surgery of aneurysm (n = 24) or dissection (n = 6) of the thoracoabdominal aorta. After femoral artery puncture, a pigtail catheter was positioned at the origin of the descending aorta. CT acquisition was performed with an intra-aortic iodinated contrast media injection (15 mL/s, 120 mL). The visualization of the AKA and the location of the feeder(s) to the AKA were independently evaluated by two observers. Interrater agreement was calculated using a kappa test. Spinal angiogram by selective catheterization was systematically performed to confirm the results of the IA-CTA. The AKA was visualized by the IA-CTA in 27/30 cases (90 %); in 26/31 (84 %) cases, the continuity with the aorta was satisfactorily seen. Interrater agreement was good for the visualization of the AKA and its feeder(s): 0.625 and 0.87, respectively. In 75 % of the cases for which the AKA was visualized, the selective catheterization confirmed the results of the IA-CTA. In the remaining 25 % of the cases, the selective catheterization could not be performed due to marked vessels' tortuosity or ostium stenosis. IA-CTA is a feasible technique in a daily practice that presents a good sensitivity for the location of the AKA. (orig.)

  7. The diagnostic value of time-resolved MR angiography with Gadobutrol at 3 T for preoperative evaluation of lower extremity tumors: Comparison with computed tomography angiography

    International Nuclear Information System (INIS)

    Wu, Gang; Jin, Teng; Li, Ting; Li, Xiaoming

    2016-01-01

    To evaluate the diagnostic value of time resolved magnetic resonance angiography with interleaved stochastic trajectory (TWIST) using Gadobutrol for preoperative evaluation of lower extremity tumors. This prospective study was approved by the local Institutional Review Board. 50 consecutive patients (31 men, 19 women, age range 18–80 years, average age 42.7 years) with lower extremity tumors underwent TWIST and computed tomography angiography (CTA). Image quality of TWIST and CTA were evaluated by two radiologists according to a 4-point scale. The degree of arterial stenosis caused by tumor was assessed using TWSIT and CTA separately, and the intra-modality agreement was determined using a kappa test. The number of feeding arteries identified by TWIST was compared with that by CTA using Wilcoxon signed rank test. The ability to identify arterio-venous fistulae (AVF) were compared using a chi-square test. Image quality of TWIST and CTA were rated as 3.88 ± 0.37 and 3.97 ± 0.16, without statistically significant difference (P = 0.135). Intra-modality agreement was excellent for the assessment of arterial stenosis (kappa = 0.806 ± 0.073 for Reader 1, kappa = 0.805 ± 0.073 for Reader 2). Readers identified AVF with TWIST in 27 of 50 cases, and identified AVF with CTA in 14 of 50 (P < 0.001). Mean feeding arteries identified with TWIST was significantly more than that with CTA (2.08 ± 1.72 vs 1.62 ± 1.52, P = 0.02). TWIST is a reliable imaging modality for the assessment of lower extremity tumors. TWIST is comparable to CTA for the identification of AVF and feeding arteries

  8. Prospective Electrocardiogram-Gated Multidetector Row Computed Tomography Coronary Angiography. Analysis of Quality Image and Radiation Dose

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Deviggiano, A.; Tajer, C.D.; Vallejos, J.; Goldsmit, A.; Garcia, M.J.

    2009-01-01

    Multidetector row computed tomography coronary angiography (MDCT-CA) has become a useful diagnostic tool for the direct quantification of coronary stenosis, for identifying coronary anomalies and for the assessment of coronary artery bypass grafts. Despite its clinical value has been questioned due to the effective radiation dose (ERD) received by each patient, radiation exposure is similar to other studies. However, different strategies are permanently tested in order to reduce the ERD maintaining adequate and diagnostic image quality. Objectives: To determine the image quality and effective radiation dose (ERD) of prospective electrocardiogram-gated multidetector row computed tomography coronary angiography (PMDCTCA) (the x-ray beam is turned on for only a short portion of diastole) compared to retrospective ECG gating (RMDCTCA) (the x-ray beam is turned on throughout the cardiac cycle) and a preliminary approach of its diagnostic accuracy compared to digital invasive coronary angiography (CA). Material and Methods: Fifty consecutive patients with suspected coronary artery disease and sinus rhythm were evaluated with PMDCT-CA and compared to a control group who underwent RMDCTCA. Image quality was analyzed by two reviewers. Interobserver concordance and ERD were determined. The diagnostic accuracy of PMDCT-CA compared to CA to detect coronary artery stenosis > 50% was assessed in 30 patients. Results: There were no significant differences in the image quality between both groups. Agreement between the reviewers for segment image quality scores was k = 0.92. Mean ERD was 3.5 mSv for PMDCT-CA compared to 9.7 and 12.9 mSv for RMDCT-CA with and without tube current modulation, respectively. Individual analysis including all segments showed that the sensitivity, specificity, positive predictive value and negative predictive value of PMDCT-CA for the detection of coronary stenosis were 94.74%, 81.82%, 90% and 90%, respectively. Conclusion: Our initial experience

  9. Comparison of 64-slice computed tomography angiography and coronary angiography for the detection and assessment of coronary artery disease in patients with angina: A systematic review

    International Nuclear Information System (INIS)

    Powell, H.; Cosson, P.

    2013-01-01

    Background: Coronary artery disease (CAD) is the leading cause of death in Western countries. It presents itself in various ways, the commonest being angina. According to the Royal College of Radiologist referral guidelines, Coronary Angiography (CA) is currently the gold standard for diagnosis and evaluation of CAD. However, due to the invasive nature and expense of CA there is a perceived need for a primary non-invasive imaging modality to supersede it. Computed tomography angiography (CTA), utilising 64-slice technology, may be a less invasive alternative to CA. Aim: To consider the research evidence for the current gold standard diagnostic test for CAD. Specifically, which is more sensitive and specific for detecting CAD in patients with angina; 64-slice CTA or CA? Inclusion Criteria: Prospective, non-randomised control trials and diagnostic accuracy studies comparing 64-slice CTA and CA were included. Participants were adults with angina with suspected or known CAD. Method: An electronic search of the databases; AMED, CINAHL, Cochrane Library, EMBASE, MEDLINE and Science Direct, was conducted between January 2004 and April 2012. Secondary hand-searching of grey literature was undertaken. Two reviewers independently determined studies for inclusion, assessed quality, using SIGN50, and extracted data. Diagnostic value of 64-slice CTA and CA was compared and analysed at patient and segment level. Results: Ten studies were included in the critical review enrolling 1188 patients. At patient level sensitivity for 64-slice CTA ranged from 88% to 100%, specificity 64–92%, PPV 86–97% and NPV 76.9–100%. At segment level sensitivity for 64-slice CTA ranged from 73% to 100%, specificity 83–98%, PPV 47–90% and NPV 89–100% Conclusion: At both patient and segment level, 64-slice CTA is a highly sensitive and specific non-invasive alternative to CA for diagnosis of significant stenosis in patients with angina. For standalone diagnosis of CAD current research would

  10. Diagnosis and screening of small hepatocellular carcinomas. Comparison of radionuclide imaging, ultrasound, computed tomography, hepatic angiography, and alpha 1-fetoprotein assay

    International Nuclear Information System (INIS)

    Takashima, T.; Matsui, O.; Suzuki, M.; Ida, M.

    1982-01-01

    Twenty-nine small (less than 5 cm) hepatocellular carcinomas in 18 patients were examined by radionuclide imaging (RN), ultrasound (US), computed tomography (CT), hepatic angiography, and serum alpha 1-fetoprotein (AFP) assay. Sensitivity was 39% with RN, 50% with US, 56% with CT, and 94% with angiography, including infusion hepatic angiography (IHA). Lesions larger than 3 cm could be detected by all of these methods; those between 2 and 3 cm were generally shown by US and CT but not RN. IHA was essential for diagnosis of lesions less than 2 cm, which were otherwise difficult or impossible to detect except with angiography. As a screening method, AFP was best, followed by US and CT. The authors recommend using AFP and US to minimize expense and radiation exposure. In questionable cases, IHA should be performed

  11. Italian Chapter of the International Society of Cardiovascular Ultrasound expert consensus document on coronary computed tomography angiography: overview and new insights.

    Science.gov (United States)

    Sozzi, Fabiola B; Maiello, Maria; Pelliccia, Francesco; Parato, Vito Maurizio; Canetta, Ciro; Savino, Ketty; Lombardi, Federico; Palmiero, Pasquale

    2016-09-01

    Coronary computed tomography angiography is a noninvasive heart imaging test currently undergoing rapid development and advancement. The high resolution of the three-dimensional pictures of the moving heart and great vessels is performed during a coronary computed tomography to identify coronary artery disease and classify patient risk for atherosclerotic cardiovascular disease. The technique provides useful information about the coronary tree and atherosclerotic plaques beyond simple luminal narrowing and plaque type defined by calcium content. This application will improve image-guided prevention, medical therapy, and coronary interventions. The ability to interpret coronary computed tomography images is of utmost importance as we develop personalized medical care to enable therapeutic interventions stratified on the bases of plaque characteristics. This overview provides available data and expert's recommendations in the utilization of coronary computed tomography findings. We focus on the use of coronary computed tomography to detect coronary artery disease and stratify patients at risk, illustrating the implications of this test on patient management. We describe its diagnostic power in identifying patients at higher risk to develop acute coronary syndrome and its prognostic significance. Finally, we highlight the features of the vulnerable plaques imaged by coronary computed tomography angiography. © 2016, Wiley Periodicals, Inc.

  12. Contrast media administration in coronary computed tomography angiography. A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Mihl, Casper; Kok, Madeleine; Wildberger, Joachim E.; Das, Marco [Maastricht Univ. Medical Center (Netherlands). CARIM School for Cardiovascular Diseases; Maastricht Univ. Medical Center (Netherlands). Radiology; Maas, Monique; Lobbes, Marc B.I. [Maastricht Univ. Medical Center (Netherlands). Radiology; Turek, Jakub; Seehofnerova, Anna [Maastricht Univ. Medical Center (Netherlands). CARIM School for Cardiovascular Diseases; Leijenaar, Ralph T.H. [GROW School for Oncology and Developmental Biology, Maastricht (Netherlands). Radiation Oncology (MAASTRO)

    2017-04-15

    Various different injection parameters influence enhancement of the coronary arteries. There is no consensus in the literature regarding the optimal contrast media (CM) injection protocol. The aim of this study is to provide an update on the effect of different CM injection parameters on the coronary attenuation in coronary computed tomographic angiography (CCTA). Studies published between January 2001 and May 2014 identified by Pubmed, Embase and MEDLINE were evaluated. Using predefined inclusion criteria and a data extraction form, the content of each eligible study was assessed. Initially, 2551 potential studies were identified. After applying our criteria, 36 studies were found to be eligible. Studies were systematically assessed for quality based on the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-II checklist. Extracted data proved to be heterogeneous and often incomplete. The injection protocol and outcome of the included publications were very diverse and results are difficult to compare. Based on the extracted data, it remains unclear which of the injection parameters is the most important determinant for adequate attenuation. It is likely that one parameter which combines multiple parameters (e.g. IDR) will be the most suitable determinant of coronary attenuation in CCTA protocols. Research should be directed towards determining the influence of different injection parameters and defining individualized optimal IDRs tailored to patient-related factors (ideally in large randomized trials). Key points: This systematic review provides insight into decisive factors on coronary attenuation. Different and contradicting outcomes are reported on coronary attenuation in CCTA. One parameter combining multiple parameters (IDR) is likely decisive in coronary attenuation. Research should aim at defining individualized optimal IDRs tailored to individual factors. Future directions should be tailored towards the influence of different injection

  13. Contrast media administration in coronary computed tomography angiography. A systematic review

    International Nuclear Information System (INIS)

    Mihl, Casper; Kok, Madeleine; Wildberger, Joachim E.; Das, Marco

    2017-01-01

    Various different injection parameters influence enhancement of the coronary arteries. There is no consensus in the literature regarding the optimal contrast media (CM) injection protocol. The aim of this study is to provide an update on the effect of different CM injection parameters on the coronary attenuation in coronary computed tomographic angiography (CCTA). Studies published between January 2001 and May 2014 identified by Pubmed, Embase and MEDLINE were evaluated. Using predefined inclusion criteria and a data extraction form, the content of each eligible study was assessed. Initially, 2551 potential studies were identified. After applying our criteria, 36 studies were found to be eligible. Studies were systematically assessed for quality based on the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-II checklist. Extracted data proved to be heterogeneous and often incomplete. The injection protocol and outcome of the included publications were very diverse and results are difficult to compare. Based on the extracted data, it remains unclear which of the injection parameters is the most important determinant for adequate attenuation. It is likely that one parameter which combines multiple parameters (e.g. IDR) will be the most suitable determinant of coronary attenuation in CCTA protocols. Research should be directed towards determining the influence of different injection parameters and defining individualized optimal IDRs tailored to patient-related factors (ideally in large randomized trials). Key points: This systematic review provides insight into decisive factors on coronary attenuation. Different and contradicting outcomes are reported on coronary attenuation in CCTA. One parameter combining multiple parameters (IDR) is likely decisive in coronary attenuation. Research should aim at defining individualized optimal IDRs tailored to individual factors. Future directions should be tailored towards the influence of different injection

  14. Assessment of the validity of sonography, computed tomography and angiography in diagnosis of the adrenals

    International Nuclear Information System (INIS)

    Georgi, M.; Hofbauer, J.; Weiss, H.; Keller, W.; Wunschik, F.; Mittelstaedt, G. von; Linder, M.; Heidelberg Univ., Mannheim; Heidelberg Univ., Mannheim

    1984-01-01

    Between 1979 and 1982, 47 patients with pathological process of the adrenals were surgically treated after preceding thorough non-evasive angiographic diagnosis (6 phaeochromocytomas, 20 adrenal adenomas, 8 adrenal hyperplasias, 5 adrenal carcinomas, 5 adrenal cysts and 3 adrenal metastases). The most consistently accurate results were obtained via adrenal phlebography with an accuracy of 94%. This was followed by non-evasive computed tomography (87%). Compared with the data given in literature, hormone determination in the adrenal venous blood was less favourable (79%). Selective adrenal arteriography, which was used less often, yielded correct results in 83% of the cases, whereas the number of accurate diagnoses achieved via sonography was lowest with 54%. (orig.) [de

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  18. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S.; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  19. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  20. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    Science.gov (United States)

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  1. Metaanalysis of Diagnostic Performance of Computed Coronary Tomography Angiography, Computed Tomography Perfusion and Computed Tomography-Fractional Flow Reserve in Functional Myocardial Ischemia Assessment versus Invasive Fractional Flow Reserve

    Science.gov (United States)

    Gonzalez, Jorge A.; Lipinski, Michael J.; Flors, Lucia F.; Shaw, Peter; Kramer, Christopher M.; Salerno, Michael

    2015-01-01

    We sought to compare the diagnostic performance of computed coronary tomography angiography (CCTA), computed tomography perfusion (CTP) and computed tomography fractional flow reserve (CT-FFR) for assessing the functional significance of coronary stenosis as defined by invasive fractional flow reserve (FFR), in patients with known or suspected coronary artery disease. CCTA has proven clinically useful for excluding obstructive CAD due to its high sensitivity and negative predictive value (NPV), however the ability of CTA to identify functionally significant CAD has remained challenging. We searched PubMed/Medline for studies evaluating CCTA, CTP or CT-FFR for the non-invasive detection of obstructive CAD as compared to catheter-derived FFR as the reference standard. Pooled sensitivity, specificity, PPV, NPV, likelihood ratios (LR), odds ratio (OR) of all diagnostic tests were assessed. Eighteen studies involving a total of 1535 patients were included. CTA demonstrated a pooled sensitivity of 0.92, specificity 0.43, PPV of 0.56 and NPV of 0.87 on a per-patient level. CT-FFR and CTP increased the specificity to 0.72 and 0.77 respectively (P=0.004 and P=0.0009)) resulting in higher point estimates for PPV 0.70 and 0.83 respectively. There was no improvement in the sensitivity. The CTP protocol involved more radiation (3.5 mSv CCTA VS 9.6 mSv CTP) and a higher volume of iodinated contrast (145 mL). In conclusion, CTP and CT-FFR improve the specificity of CCTA for detecting functionally significant stenosis as defined by invasive FFR on a per-patient level; both techniques could advance the ability to non-invasively detect the functional significance of coronary lesions. PMID:26347004

  2. Limitations of 64-Detector-Row Computed Tomography Coronary Angiography: Calcium and Motion but not Short Experience

    International Nuclear Information System (INIS)

    Mir-Akbari, H.; Ripsweden, J.; Jensen, J.; Pichler, P.; Sylven, C.; Cederlund, K.; Rueck, A.

    2009-01-01

    Background: Recently, 64-detector-row computed tomography coronary angiography (CTA) has been introduced for the noninvasive diagnosis of coronary artery disease. Purpose: To evaluate the diagnostic capacity and limitations of a newly established CTA service. Material and Methods: In 101 outpatients with suspected coronary artery disease, 64-detector-row CTA (VCT Lightspeed 64; GE Healthcare, Milwaukee, WI., USA) was performed before invasive coronary angiography (ICA). The presence of >50% diameter coronary stenosis on CTA was rated by two radiologists recently trained in CTA, and separately by an experienced colleague. Diagnostic performance of CTA was calculated on segment, vessel, and patient levels, using ICA as a reference. Segments with a proximal reference diameter <2 mm or with stents were not analyzed. Results: In 51 of 101 patients and 121 of 1280 segments, ICA detected coronary stenosis. In 274 of 1280 (21%) segments, CTA had non-diagnostic image quality, the main reasons being severe calcifications (49%), motion artifacts associated with high or irregular heart rate (45%), and low contrast opacification (14%). Significantly more women (43%) had non-diagnostic scans compared to men (20%). A heart rate above 60 beats per minute was associated with significantly more non-diagnostic patients (38% vs. 18%). In the 1006 diagnostic segments, CTA had a sensitivity of 78%, specificity of 95%, positive predictive value (PPV) of 54%, and negative predictive value (NPV) of 98% for detecting significant coronary stenosis. In 29 patients, CTA was non-diagnostic. In the remaining 72 patients, sensitivity was 100%, specificity 65%, PPV 79%, and NPV 100%. The use of a more experienced CTA reader did not improve diagnostic performance. Conclusion: CTA had a very high negative predictive value, but the number of non-diagnostic scans was high, especially in women. The main limitations were motion artifacts and vessel calcifications, while short experience in CTA did not

  3. The Basilar Artery on Computed Tomography Angiography Score for Acute Basilar Artery Occlusion Treated with Mechanical Thrombectomy.

    Science.gov (United States)

    Yang, Haihua; Ma, Ning; Liu, Lian; Gao, Feng; Mo, Dapeng; Miao, Zhongrong

    2018-06-01

    Recently, the Basilar Artery on Computed Tomography Angiography (BATMAN) score predicts clinical outcome of acute basilar artery occlusion (BAO), yet there is no extensive external validation. The purpose of this study was to validate the prognostic value of BATMAN scoring system for the prediction of clinical outcome in patients with acute BAO treated with endovascular mechanical thrombectomy by using cerebral digital subtraction angiography (DSA). We analyzed the clinical and angiographic data of consecutive patients with acute BAO from March 2012 to November 2016. The BATMAN scoring system was used to assess the collateral status and thrombus burden. Thrombolysis in Cerebral Infarction (TICI) score 2b-3 was defined as successful recanalization. Receiver operating characteristic (ROC) curve was used to determine the area under the curve (AUC) and the optimum cutoff value. Multivariate regression analysis was used to identify the predictor of clinical outcome. This study included 63 patients with acute BAO who underwent mechanical thrombectomy. Of these patients, 90.5% (57/63) achieved successful recanalization (TICI, 2b-3) and 34.9% (22/63) had a favorable outcome (modified Rankin Scale score 0-2). ROC analysis indicated that the AUC of the BATMAN score was .722 (95% confidence interval [CI], .594-.827), and the optimal cutoff value was 3 (sensitivity = 72.73, specificity = 63.41). In multivariate logistic regression analysis, the BATMAN score higher than 3 was associated with favorable outcome (odds ratio, 5.214; 95% CI, 1.47-18.483; P = .011). The BATMAN score on DSA seems to predict the functional outcome in patients of acute BAO treated with mechanical thrombectomy. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. Differentiation of acute total occlusion of coronary artery from chronic total occlusion in coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kwag, Hyon Joo [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)

    2012-08-15

    To compare the features of coronary computed tomography angiography (CCTA) imaging of the patients with acute total occlusion (ATO) of coronary artery with those of chronic total occlusion (CTO). CCTA of 26 patients with complete interruption of the coronary artery in CCTA and occlusion in conventional coronary angiography, were retrospectively analyzed. Discrimination between the ATO group (n = 11, patients with non ST elevation myocardial infarction or unstable angina) and the CTO group (n = 15, patients with stable angina or nonspecific symptom) was arbitrarily determined by clinical diagnosis. Lesion length, remodeling index (RI), plaque density measured by Hounsfield units (HU), plaque composition, percentage attenuation drop across the lesion, and presence of myocardial thinning were evaluated. Comparisons between the ATO and CTO groups revealed significantly shorter lesion length in the ATO group (0.40 cm vs. 1.87 cm, respectively; p = 0.001), and significantly higher RI (1.56 vs. 1.10, respectively; p = 0.004). Plaque density of the ATO group was lower (37.0 HU vs. 104.7 HU, respectively; p < 0.001) and non calcified plaque was frequently seen in the ATO group (72.7% vs. 26.7%, respectively; p = 0.02). Percentage attenuation drop across the lesion was lower for the ATO group (10.92% vs. 25.44%, respectively; p = 0.005). Myocardial thinning was exclusively observed in the CTO group (seven of 15 patients, p = 0.01). CCTA shows various statistically significant differences between the ATO and CTO groups.

  5. Differentiation of acute total occlusion of coronary artery from chronic total occlusion in coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Kwag, Hyon Joo

    2012-01-01

    To compare the features of coronary computed tomography angiography (CCTA) imaging of the patients with acute total occlusion (ATO) of coronary artery with those of chronic total occlusion (CTO). CCTA of 26 patients with complete interruption of the coronary artery in CCTA and occlusion in conventional coronary angiography, were retrospectively analyzed. Discrimination between the ATO group (n = 11, patients with non ST elevation myocardial infarction or unstable angina) and the CTO group (n = 15, patients with stable angina or nonspecific symptom) was arbitrarily determined by clinical diagnosis. Lesion length, remodeling index (RI), plaque density measured by Hounsfield units (HU), plaque composition, percentage attenuation drop across the lesion, and presence of myocardial thinning were evaluated. Comparisons between the ATO and CTO groups revealed significantly shorter lesion length in the ATO group (0.40 cm vs. 1.87 cm, respectively; p = 0.001), and significantly higher RI (1.56 vs. 1.10, respectively; p = 0.004). Plaque density of the ATO group was lower (37.0 HU vs. 104.7 HU, respectively; p < 0.001) and non calcified plaque was frequently seen in the ATO group (72.7% vs. 26.7%, respectively; p = 0.02). Percentage attenuation drop across the lesion was lower for the ATO group (10.92% vs. 25.44%, respectively; p = 0.005). Myocardial thinning was exclusively observed in the CTO group (seven of 15 patients, p = 0.01). CCTA shows various statistically significant differences between the ATO and CTO groups

  6. Association of Dyslipidemia and Sex With Coronary Artery Calcium Assessed by Coronary Computed Tomography Angiography.

    Science.gov (United States)

    Asami, Masahiko; Yamaji, Kyohei; Aoki, Jiro; Tanimoto, Shuzou; Watanabe, Mika; Horiuchi, Yu; Furui, Koichi; Kato, Nahoko; Hara, Kazuhiro; Tanabe, Kengo

    2017-10-21

    Previous studies reporting that statin increases coronary artery calcium (CAC) were conducted exclusively on patients with statin as a prevention, regardless of the presence or absence of dyslipidemia. The impact of sex on CAC has not been fully evaluated. We aimed to determine the association of dyslipidemia and sex with CAC using 320-row multi-detector computed tomography (MDCT).Of the 356 consecutive patients who underwent coronary MDCT, 251 patients were enrolled, after excluding those with prior stenting and/or coronary bypass grafting or images showing motion artifacts. The primary outcome measures were the percent calcium volume (PCV) and percent atheroma volume (PAV) per coronary vessel.Multivariable analyses indicated that PCV was significantly higher in dyslipidemia patients without statins than in the subjects without dyslipidemia [partial regression coefficient (PRC): 2.59, 95% confidence interval (CI): 0.83 to 4.34, P = 0.004]. In contrast, PCV was similar in dyslipidemia patients taking statins and those without dyslipidemia (PRC: -1.09, 95% CI: -2.82 to 0.65, P = 0.22). There was no significant difference in PCV between men and women, although women exhibited a significantly lower PAV (PRC: -2.87, 95% CI: -4.54 to -1.20, P = 0.001).In low-risk patients, these results could be translated into hypotheses, which should be tested in future prospective studies. Furthermore, there was no significant difference in CAC between men and women, but women had lower PAV than men.

  7. Evaluation of patients radiation dose from computed tomography during lower peripheral angiography procedure

    International Nuclear Information System (INIS)

    Khlafallah, Leena Ahmed Ali

    2015-09-01

    The purpose of this study was to evaluate patient radiation doses in lower peripheral angiography CT examinations in Sudan. Survey was conducted in four major hospitals which almost carry out lower peripheral angiography procedures in Sudan at the time of study. All hospitals were equipped with 64 slices multi detectors CT from Toshiba (Japan). The total number of patients was 74. Information on patient's genders and ages, exposure technique factors and radiation dose were collected. The procedures performed in multi phases, up to five phases covering part of the abdomen region, which can make patients exposure reasonably high. CTDI values in the different phases ranged between (13-30) mGy. The total DLP in the four hospitals were 6888.75, 5065.05, 6608.88 and 5754.9 mGy.cm. This study provided first survey for patient dose during lower peripheral angiography procedures in Sudan. Taking into account that the CT machines were similar: the variation between patient's DLP and CTDI values in the different hospitals indicated the need of optimization of radiation protection. Staff training and awareness on factors affecting patient dose are essential.(Author)

  8. Short term high dose atorvastatin for the prevention of contrast-induced nephropathy in patients undergoing computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Hamid Sanei

    2014-09-01

    Full Text Available BACKGROUND: Statins are shown effective by some studies in preventing contrast-induced nephropathy (CIN. We evaluated the effectiveness of atorvastatin in the prevention of CIN in computed tomography angiography (CTA candidates. METHODS: This study was conducted on patients referring for elective CTA with normal renal function. Patients received atorvastatin (80 mg/day or placebo from 24 h before to 48 h after administration of the contrast material. Serum creatinine was measured before and 48 h after contrast material injection. CIN was defined as an increase in serum creatinine level of ≥ 0.5 mg/dl or ≥ 25% of the baseline creatinine. RESULTS: A total of 236 patients completed the study; 115 atorvastatin, 121 placebo, mean age = 58.40 ± 9.80 year, 68.6% male. Serum creatinine increased after contrast material injection in both the atorvastatin (1.00 ± 0.16-1.02 ± 0.15 mg/dl, P = 0.017 and placebo groups (1.03 ± 0.17-1.08 ± 0.18 mg/dl, P < 0.001. Controlling for age, gender, comorbidities, drug history, and baseline serum creatinine level, patients who received atorvastatin experienced less increase in serum creatinine after contrast material injection (beta = 0.127, P = 0.034. However, there was no difference between the atorvastatin and placebo groups in the incidence of CIN (4.3 vs. 5.0%, P = 0.535. CONCLUSION: In patients undergoing CTA, a short-term treatment with high dose atorvastatin is effective in preventing contrast-induced renal dysfunction, in terms of less increase in serum creatinine level after contrast material injection. Further trials including larger sample of patients and longer follow-ups are warranted.   Keywords: Kidney Diseases, Multidetector Computed Tomography, Contrast Media, Hydroxymethylglutaryl-CoA Reductase Inhibitors, Atorvastatin 

  9. The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles

    Directory of Open Access Journals (Sweden)

    Nicolette Cassel

    2013-05-01

    Full Text Available Computed tomography thoracic angiography studies were performed on five adult beagles using the bolus tracking (BT technique and the test bolus (TB technique, which were performed at least two weeks apart. For the BT technique, 2 mL/kg of 300 mgI/mL iodinated contrast agent was injected intravenously. Scans were initiated when the contrast in the aorta reached 150 Hounsfield units (HU. For the TB technique, the dogs received a test dose of 15% of 2 mL/kg of 300 mgI/mL iodinated contrast agent, followed by a series of low dose sequential scans. The full dose of the contrast agent was then administered and the scans were conducted at optimal times as identified from time attenuation curves. Mean attenuation in HU was measured in the aorta (Ao and right caudal pulmonary artery (rCPA. Additional observations included the study duration, milliAmpere (mA, computed tomography dose index volume (CTDI[vol] and dose length product (DLP. The attenuation in the Ao (BT = 660 52 HU ± 138 49 HU, TB = 469 82 HU ± 199 52 HU, p = 0.13 and in the rCPA (BT = 606 34 HU ± 143 37 HU, TB = 413 72 HU ± 174.99 HU, p = 0.28 did not differ significantly between the two techniques. The BT technique was conducted in a significantly shorter time period than the TB technique (p = 0.03. The mean mA for the BT technique was significantly lower than the TB technique (p = 0.03, as was the mean CTDI(vol (p = 0.001. The mean DLP did not differ significantly between the two techniques (p = 0.17. No preference was given to either technique when evaluating the Ao or rCPA but the BT technique was shown to be shorter in duration and resulted in less DLP than the TB technique.

  10. Anatomical variation of celiac axis, superior mesenteric artery, and hepatic artery: Evaluation with multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Maryam Farghadani

    2016-01-01

    Full Text Available Background: The celiac axis, superior mesenteric artery (SMA, and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT angiography of upper abdomen arteries. Materials and Methods: MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Results: Three hundred and eighty-eight (63.9% of the 607 patients had classic arterial anatomy and 219 (36.1% patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA from SMA (9.6%, and the next common variation was the origin of the left hepatic artery (LHA from the left gastric artery (6.9%. Variations in the origin of the common hepatic artery (CHA were seen in 16 (2.6% patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8% patients and from the aorta in 8 (1.3% patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8% patients. Conclusion: The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.

  11. Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Hasan B Altinsoy

    2017-01-01

    Full Text Available Objective: This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. Materials and Methods: Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass grafting (CABG were randomly selected for this prospective study. MDCT angiography was performed for 110 examinations of forearm and hand arterial anatomy. Prior to MDCT, Allen tests were performed in all patients with a normal result, except four. Thirteen patients had diabetes mellitus (DM, 8 had peripheral artery occlusive disease, and 19 had a history of smoking. Results: All arteries, including axillary, ulnar artery (UA and radial artery (RA, were clearly visualized in all patients. Upper extremity anatomical and pathological results were examined in 16 patients (29.1%. Severely calcified RA and/or UA were found in 6 patients who had a moderate renal failure. Nearly total occlusion of the RA was detected in another two patients. Focal intimal RA calcification was recorded in 1 female and 3 male patients. Ten patients who had severe calcification or intimal sclerosis of the upper extremity arteries had DM. The remaining patients had normal forehand arterial circulation. A persistent median artery with the absence of radial and ulnar arteries and a high bifurcation of RA from the brachial artery was detected as an anatomic variation in seven patients (12.7%. Conclusions: The major advantages of MDCT angiography are its non-invasiveness and the ability to detect calcific subadventitial plaques, which are difficult to diagnose using conventional angiography. MDCT may be used as a safe and non-invasive method to assess RA and UA prior to harvesting the upper limb artery. Preoperative imaging of forehand arteries is a means to avoid unnecessary forearm

  12. The effect of blood pressure on non-invasive fractional flow reserve derived from coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Akira [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Coenen, Adriaan; Lubbers, Marisa M.; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Departmenet of Cardiology, Rotterdam (Netherlands); Kido, Teruhito; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Kido, Tomoyuki [Matsuyama Saiseikai Hospital, Department of Radiology, Matsuyama, Ehime (Japan); Yamashita, Natsumi [Clinical Research Center, National Hospital Organization Shikoku Cancer Center, Division of Clinical Biostatistics, Section of Cancer Prevention and Epidemiology, Matsuyama, Ehime (Japan); Watanabe, Kouki [Matsuyama Saiseikai Hospital, Department of Cardiology, Matsuyama, Ehime (Japan); Krestin, Gabriel P. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2017-04-15

    The aim of this study is to assess the effect of blood pressure (BP) on coronary computed tomography angiography (CTA) derived computational fractional flow reserve (CTA-FFR). Twenty-one patients who underwent coronary CTA and invasive FFR were retrospectively identified. Ischemia was defined as invasive FFR ≤0.80. Using a work-in-progress computational fluid dynamics algorithm, CTA-FFR was computed with BP measured before CTA, and simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg respectively. Correlation between CTA-FFR and invasive FFR was assessed using Pearson test. The repeated measuring test was used for multiple comparisons of CTA-FFR values by simulated BP inputs. Twenty-nine vessels (14 with invasive FFR ≤0.80) were assessed. The average CTA-FFR for measured BP (134 ± 20/73 ± 12 mmHg) was 0.77 ± 0.12. Correlation between CTA-FFR by measured BP and invasive FFR was good (r = 0.735, P < 0.001). For simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg, the CTA-FFR increased: 0.69 ± 0.13, 0.73 ± 0.12, 0.75 ± 0.12, 0.77 ± 0.11, 0.79 ± 0.11, and 0.81 ± 0.10 respectively (P < 0.05). Measurement of the BP just before CTA is preferred for accurate CTA-FFR simulation. BP variations in the common range slightly affect CTA-FFR. However, inaccurate BP assumptions differing from the patient-specific BP could cause misinterpretation of borderline significant lesions. (orig.)

  13. Automatic assessment of coronary artery calcium score from contrast-enhanced 256-row coronary computed tomography angiography.

    Science.gov (United States)

    Rubinshtein, Ronen; Halon, David A; Gaspar, Tamar; Lewis, Basil S; Peled, Nathan

    2014-01-01

    The coronary artery calcium score (CS), an independent predictor of cardiovascular events, can be obtained from a stand-alone nonenhanced computed tomography (CT) scan (CSCT) or as an additional nonenhanced procedure before contrast-enhanced coronary CT angiography (CCTA). We evaluated the accuracy of a novel fully automatic tool for computing CS from the CCTA examination. One hundred thirty-six consecutive symptomatic patients (aged 59 ± 11 years, 40% female) without known coronary artery disease who underwent both 256-row CSCT and CCTA were studied. Original scan reconstruction (slice thickness) was maintained (3 mm for CSCT and 0.67 mm for CCTA). CS was computed from CCTA by an automatic tool (COR Analyzer, rcadia Medical Imaging, Haifa, Israel) and compared with CS results obtained by standard assessment of nonenhanced CSCT (HeartBeat CS, Philips, Cleveland, Ohio). We also compared both methods for classification into 5 commonly used CS categories (0, 1 to 10, 11 to 100, 101 to 400, >400 Agatston units). All scans were of diagnostic quality. CS obtained by the COR Analyzer from CCTA classified 111 of 136 (82%) of patients into identical categories as CS by CSCT and 24 of remaining 25 into an adjacent category. Overall, CS values from CCTA showed high correlation with CS values from CSCT (Spearman rank correlation = 0.95, p automatically computed from 256-row CCTA correlated highly with standard CS values obtained from nonenhanced CSCT. CS obtained directly from CCTA may obviate the need for an additional scan and attendant radiation. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. The effect of blood pressure on non-invasive fractional flow reserve derived from coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Kurata, Akira; Coenen, Adriaan; Lubbers, Marisa M.; Nieman, Koen; Kido, Teruhito; Mochizuki, Teruhito; Kido, Tomoyuki; Yamashita, Natsumi; Watanabe, Kouki; Krestin, Gabriel P.

    2017-01-01

    The aim of this study is to assess the effect of blood pressure (BP) on coronary computed tomography angiography (CTA) derived computational fractional flow reserve (CTA-FFR). Twenty-one patients who underwent coronary CTA and invasive FFR were retrospectively identified. Ischemia was defined as invasive FFR ≤0.80. Using a work-in-progress computational fluid dynamics algorithm, CTA-FFR was computed with BP measured before CTA, and simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg respectively. Correlation between CTA-FFR and invasive FFR was assessed using Pearson test. The repeated measuring test was used for multiple comparisons of CTA-FFR values by simulated BP inputs. Twenty-nine vessels (14 with invasive FFR ≤0.80) were assessed. The average CTA-FFR for measured BP (134 ± 20/73 ± 12 mmHg) was 0.77 ± 0.12. Correlation between CTA-FFR by measured BP and invasive FFR was good (r = 0.735, P < 0.001). For simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg, the CTA-FFR increased: 0.69 ± 0.13, 0.73 ± 0.12, 0.75 ± 0.12, 0.77 ± 0.11, 0.79 ± 0.11, and 0.81 ± 0.10 respectively (P < 0.05). Measurement of the BP just before CTA is preferred for accurate CTA-FFR simulation. BP variations in the common range slightly affect CTA-FFR. However, inaccurate BP assumptions differing from the patient-specific BP could cause misinterpretation of borderline significant lesions. (orig.)

  15. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    International Nuclear Information System (INIS)

    Saba, Luca; Mallarini, Giorgio; Anzidei, Michele; Lucatelli, Pierleone

    2011-01-01

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  16. Abdominal lymph node metastases of hepatocellular carcinoma diagnosed by computed tomography and angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Hironobu; Oi, Hiromichi [Osaka Univ. (Japan). Research Inst. for Microbial Diseases; Tanaka, Takeshi; Sai, Soomi; Hori, Shinichi

    1984-04-01

    CT scans of 164 patients with hepatocellular carcinoma were studied, and abdominal lymph node metastases were detected in 13 cases. Most of these lymph node metastases occured in periportal, peripancreatic and paraaortic lymph nodes. Ten instances of each these metastases were identified by CT. Six of the patients had metastases in all three sites. In 9 of 13 cases, lymph node metastases were demonstrated by angiography and various degrees of contrast material stain were seen. Lymph node metastasis of hepatocellular carcinoma is apt to be hypervascular. Most of hepatocellular carcinoma with lymph node metastasis showed infiltrative growth, and tumor thrombosis in the portal vein was commonly complicated.

  17. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  18. Multidetector computed tomography angiography in clinically suspected hyperacute ischemic stroke in the anterior circulation: an etiological workup in a cohort of Brazilian patients

    OpenAIRE

    Pacheco, Felipe Torres; Littig, Ingrid Aguiar; Gagliardi, Rubens Jose; Rocha, Antônio Jose da

    2015-01-01

    Objective The potential of computed tomography angiography (CTA) was assessed for early determination of stroke subtypes in a Brazilian cohort of patients with stroke. Method From July 2011 to July 2013, we selected patients with suspected hyperacute stroke (< 6 hours). Intracranial and cervical arteries were scrutinized on CTA and their imaging features were correlated with concurrent subtype of stroke. Results Stroke was documented in 50/106 selected patients (47.2%) based on both clinical ...

  19. Investigation of vessel visibility of iterative reconstruction method in coronary computed tomography angiography using simulated vessel phantom

    International Nuclear Information System (INIS)

    Inoue, Takeshi; Uto, Fumiaki; Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Hoshino, Takashi; Miura, Youhei; Terakawa, Syouichi

    2012-01-01

    Iterative reconstruction methods can reduce the noise of computed tomography (CT) images, which are expected to contribute to the reduction of patient dose CT examinations. The purpose of this study was to investigate impact of an iterative reconstruction method (iDose 4 , Philips Healthcare) on vessel visibility in coronary CT angiography (CTA) by using phantom studies. A simulated phantom was scanned by a CT system (iCT, Philips Healthcare), and the axial images were reconstructed by filtered back projection (FBP) and given a level of 1 to 7 (L1-L7) of the iterative reconstruction (IR). The vessel visibility was evaluated by a quantitative analysis using profiles across a 1.5-mm diameter simulated vessel as well as visual evaluation for multi planar reformation (MPR) images and volume rendering (VR) images in terms of the normalized-rank method with analysis of variance. The peak CT value of the profiles decreased with IR level and full width at half maximum of the profile also decreased with the IR level. For normalized-rank method, there was no statistical difference between FBP and L1 (20% dose reduction) for both MPR and VR images. The IR levels higher than L1 sacrificed the spatial resolution for the 1.5-mm simulated vessel, and their visual vessel visibilities were significantly inferior to that of the FBP. (author)

  20. Added value of delayed computed tomography angiography in primary intracranial hemorrhage and hematoma size for predicting spot sign.

    Science.gov (United States)

    Wu, Te Chang; Chen, Tai Yuan; Shiue, Yow Ling; Chen, Jeon Hor; Hsieh, Tsyh-Jyi; Ko, Ching Chung; Lin, Ching Po

    2018-04-01

    Background The computed tomography angiography (CTA) spot sign represents active contrast extravasation within acute primary intracerebral hemorrhage (ICH) and is an independent predictor of hematoma expansion (HE) and poor clinical outcomes. The spot sign could be detected on first-pass CTA (fpCTA) or delayed CTA (dCTA). Purpose To investigate the additional benefits of dCTA spot sign in primary ICH and hematoma size for predicting spot sign. Material and Methods This is a retrospective study of 100 patients who underwent non-contrast CT (NCCT) and CTA within 24 h of onset of primary ICH. The presence of spot sign on fpCTA or dCTA, and hematoma size on NCCT were recorded. The spot sign on fpCTA or dCTA for predicting significant HE, in-hospital mortality, and poor clinical outcomes (mRS ≥ 4) are calculated. The hematoma size for prediction of CTA spot sign was also analyzed. Results Only the spot sign on dCTA could predict high risk of significant HE and poor clinical outcomes as on fpCTA ( P spot sign on fpCTA or dCTA in the absence of intraventricular and subarachnoid hemorrhage. Conclusion This study clarifies that dCTA imaging could improve predictive performance of CTA in primary ICH. Furthermore, the XY value is the best predictor for CTA spot sign.

  1. Prognostic value of incidental hypervascular micronodules detected on cone-beam computed tomography angiography of patients with liver metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Odisio, Bruno C.; Mahvash, Armeen; Gupta, Sanjay; Tam, Alda L.; Murthy, Ravi [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology, Division of Diagnostic Imaging, Houston, TX (United States); Cox, Veronica L.; Faria, Silvana C. [The University of Texas MD Anderson Cancer Center, Diagnostic Radiology, Houston, TX (United States); Yamashita, Suguru; Vauthey, Jean-Nicolas [The University of Texas MD Anderson Cancer Center, Surgical Oncology, Houston, TX (United States); Shi, Xiao [Baylor College of Medicine, Department of Diagnostic Radiology, Houston, TX (United States); Ensor, Joe [Biostatistics of the Houston Methodist Cancer Center, Houston, TX (United States); Jones, Aaron K. [The University of Texas MD Anderson Cancer Center, Imaging Physics, Houston, TX (United States)

    2017-11-15

    To determine the clinical relevance of incidentally-found hypervascular micronodules (IHM) on cone-beam computed tomography angiography (CBCTA) in patients with liver metastasis undergoing transarterial (chemo)embolization (TACE/TAE). This was a HIPAA-compliant institutional review board-approved single-institution retrospective review of 95 non-cirrhotic patients (52 men; mean age, 60 years) who underwent CBCTA prior to (chemo)embolic delivery. IHM were defined by the presence of innumerable subcentimetre hepatic parenchymal hypevascular foci not detected on pre-TACE/TAE contrast-enhanced cross-sectional imaging. Multivariate analysis was performed to compare time to tumour progression (TTP) between patients with and without IHM. IHM were present in 21 (22%) patients. Patients with IHM had a significantly shorter intrahepatic TTP determined by a higher frequency of developing new liver metastasis (hazard ratio [HR]: 1.99; 95% confidence interval [CI] 1.08-3.67, P= 0.02). Patients with IHM trended towards a shorter TTP of the tumour(s) treated with TACE/TAE (HR: 1.72; 95% CI: 0.98-3.01, P= 0.056). Extrahepatic TTP was not significantly different between the two cohorts (P= 0.27). Patients with IHM on CBCTA have worse prognosis due to a significantly higher risk of developing new hepatic tumours. Further work is needed to elucidate its underlying mechanisms of pathogenesis. (orig.)

  2. Long-term prognostic performance of low-dose coronary computed tomography angiography with prospective electrocardiogram triggering

    Energy Technology Data Exchange (ETDEWEB)

    Clerc, Olivier F.; Kaufmann, Basil P.; Possner, Mathias; Liga, Riccardo; Vontobel, Jan; Mikulicic, Fran; Graeni, Christoph; Benz, Dominik C.; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Gaemperli, Oliver; Kaufmann, Philipp A.; Buechel, Ronny R. [University Hospital Zurich, Cardiac Imaging, Department of Nuclear Medicine, Zurich (Switzerland)

    2017-11-15

    To assess long-term prognosis after low-dose 64-slice coronary computed tomography angiography (CCTA) using prospective electrocardiogram-triggering. We included 434 consecutive patients with suspected or known coronary artery disease referred for low-dose CCTA. Patients were classified as normal, with non-obstructive or obstructive lesions, or previously revascularized. Coronary artery calcium score (CACS) was assessed in 223 patients. Follow-up was obtained regarding major adverse cardiac events (MACE): cardiac death, myocardial infarction and elective revascularization. We performed Kaplan-Meier analysis and Cox regressions. Mean effective radiation dose was 1.7 ± 0.6 mSv. At baseline, 38% of patients had normal arteries, 21% non-obstructive lesions, 32% obstructive stenosis and 8% were revascularized. Twenty-nine patients (7%) were lost to follow-up. After a median follow-up of 6.1 ± 0.6 years, MACE occurred in 0% of patients with normal arteries, 6% with non-obstructive lesions, 30% with obstructive stenosis and 39% of those revascularized. MACE occurrence increased with increasing CACS (P < 0.001), but 4% of patients with CACS = 0 experienced MACE. Multivariate Cox regression identified obstructive stenosis, lesion burden in CCTA and CACS as independent MACE predictors (P ≤ 0.001). Low-dose CCTA with prospective electrocardiogram-triggering has an excellent long-term prognostic performance with a warranty period >6 years for patients with normal coronary arteries. (orig.)

  3. Cases similar to the cerebrovascular 'Moyamoya disease'. Investigation by angiography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomura, Noriaki; Inugami, Atsushi; Higano, Shuichi; Fujita, Hideaki; Abe, Toushi; Shishido, Fumio; Uemura, Kazuo

    1988-10-01

    Findings of cerebral computed tomographies were investigated in 13 patients who did not satisfy the criteria of cerebrovascular Moyamoya disease, but showed the Moyamoya vessels (so-called pseudo-Moyamoya disease). Their ages ranged from 15 to 70 years old. Single patients were diagnosed as having pituitary adenoma after radiation therapy, head trauma, aplastic anemia, and the Rainoud phenomenon, and five as having hypertension. Angiography revealed occlusion and stenosis in the unilateral carotid forks in 7 and 5 patients, respectively. Other appearances included transdural anastomosis via the superficial temporal arteries, the anterior ethmoid arteries, and the collateral pathway from the perforating branches to the cortical branches. Low density areas were seen on CT in 10 patients, seven of whom had multiple areas. Low density areas were seen in the cerebral basal ganglia, watershed zone, and the outer side of the lateral cerebral body, in that order. Four patients had intracranial hemorrhage, subarachnoid hemorrhage, and hemorrhage infarction. Pseudo-Moyamoya disease was sometimes of the incomplete form of the cerebrovascular Moyamoya disease, and attributable to arterial stenosis or constricture due to radiation therapy. (Namekawa, K.).

  4. Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice Computed Tomography coronary angiography

    International Nuclear Information System (INIS)

    Cademartiri, Filippo; Mollet, Nico R.; Kriestin, Gabriel P.; Runza, Giuseppe; Bartolotta, Tommaso Vincenzo; Galia, Massimo; Midiri, Massimo; Belgrano, Manuel; Pozzi Mucelli, Roberto

    2005-01-01

    Purpose. To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). Materials and methods. One hundred patients (88 males; 59±11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/nl at 4 ml/s and the scan delay was defined with a bolus tracking technique. In all patients vascular enhancement was measured in the aortic root, and the left and the right coronary arteries. The average enhancement was used to divide the population in two groups of 50 patients each, one with lower enhancement (Low), and one with higher enhancement (High). In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (≥50% lumen reduction) was evaluated in vessels ≥2mm in diameter using quantitative CA as the reference standard. The differences in diagnostic accuracy were compared with a Chi-square test and a p [it

  5. Long-term prognostic performance of low-dose coronary computed tomography angiography with prospective electrocardiogram triggering

    International Nuclear Information System (INIS)

    Clerc, Olivier F.; Kaufmann, Basil P.; Possner, Mathias; Liga, Riccardo; Vontobel, Jan; Mikulicic, Fran; Graeni, Christoph; Benz, Dominik C.; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Gaemperli, Oliver; Kaufmann, Philipp A.; Buechel, Ronny R.

    2017-01-01

    To assess long-term prognosis after low-dose 64-slice coronary computed tomography angiography (CCTA) using prospective electrocardiogram-triggering. We included 434 consecutive patients with suspected or known coronary artery disease referred for low-dose CCTA. Patients were classified as normal, with non-obstructive or obstructive lesions, or previously revascularized. Coronary artery calcium score (CACS) was assessed in 223 patients. Follow-up was obtained regarding major adverse cardiac events (MACE): cardiac death, myocardial infarction and elective revascularization. We performed Kaplan-Meier analysis and Cox regressions. Mean effective radiation dose was 1.7 ± 0.6 mSv. At baseline, 38% of patients had normal arteries, 21% non-obstructive lesions, 32% obstructive stenosis and 8% were revascularized. Twenty-nine patients (7%) were lost to follow-up. After a median follow-up of 6.1 ± 0.6 years, MACE occurred in 0% of patients with normal arteries, 6% with non-obstructive lesions, 30% with obstructive stenosis and 39% of those revascularized. MACE occurrence increased with increasing CACS (P < 0.001), but 4% of patients with CACS = 0 experienced MACE. Multivariate Cox regression identified obstructive stenosis, lesion burden in CCTA and CACS as independent MACE predictors (P ≤ 0.001). Low-dose CCTA with prospective electrocardiogram-triggering has an excellent long-term prognostic performance with a warranty period >6 years for patients with normal coronary arteries. (orig.)

  6. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  7. Computed Tomography Angiography in Patients Evaluated for Acute Pulmonary Embolism with Low Serum D-dimer Levels: A Prospective Study.

    Science.gov (United States)

    Gimber, Lana Hirai; Travis, R Ing; Takahashi, Jayme M; Goodman, Torrey L; Yoon, Hyo-Chun

    2009-01-01

    Pulmonary computed tomography angiography (CTA) and the Wells criteria both have interobserver variability in the assessment of pulmonary embolism (PE). Quantitative D-dimer assay findings have been shown to have a high negative predictive value in patients with low pretest probability of PE. Evaluate roles for clinical probability and CTA in Emergency Department (ED) patients suspected of acute PE but having a low serum D-dimer level. Prospective observational study of ED patients with possible PE who underwent pulmonary CTA and had D-dimer levels tiebreaker. Pulmonary CTA findings positive for acute embolism should be viewed with caution, especially if the suspected PE is in a distal segmental or subsegmental artery in a patient with a serum D-dimer level of

  8. Anatomical criteria of malignancy by computed tomography angiography in patients with anomalous coronary arteries with an interarterial course

    Energy Technology Data Exchange (ETDEWEB)

    Ashrafpoor, Golmehr [Assistance Publique-Hopitaux de Paris, Hopital Europeen Georges Pompidou, Universite Paris Descartes, Department of Radiology, Cardiovascular Imaging Unit, Paris (France); Danchin, Nicolas [Assistance Publique-Hopitaux de Paris, Hopital Europeen Georges Pompidou, Universite Paris Descartes, Department of Cardiology, Paris (France); Houyel, Lucile; Belli, Emre [Centre Chirurgical Marie-Lannelongue, Department of Congenital Cardiac Surgery, Le Plessis-Robinson (France); Ramadan, Ramzi [Centre Chirurgical Marie-Lannelongue, Department of Cardiac Surgery, Le Plessis-Robinson (France); Paul, Jean-Francois [Institut Mutualiste Montsouris, Department of Radiology, Paris (France)

    2014-10-11

    We sought to determine the relation between major adverse cardiac events (MACE) and anatomical criteria assessed by coronary computed tomography angiography (CCTA) in patients with an anomalous coronary artery with an interarterial course (ACAIAC). We selected CCTA studies of patients with an ACAIAC from a database of 4,160 examinations and studied anatomical criteria according to the presence of prior MACE, defined as syncope, unstable angina, myocardial infarction and resuscitated sudden cardiac death. There were 19 patients (18 males) with an ACAIAC during the study period (incidence 0.46 %). Seven patients with prior MACE were younger (26 years vs 59 years, p < 0.001), had a smaller minimal lumen area (3.6 mm{sup 2} vs 9.0 mm{sup 2}, p = 0.001), a higher degree of area stenosis (57 % vs 24 %, p = 0.001), a longer interarterial course (14.7 vs 8.6 mm, p = 0.003) and a smaller proximal segment width (1.6 mm vs 2.5 mm, p = 0.02) compared with the 12 patients without prior MACE. All patients with MACE had the following concomitant anatomical characteristics: minimum lumen area ≤4 mm{sup 2}, an area stenosis ≥50 % and intra-arterial length >10 mm Prior MACE is associated with specific anatomical CCTA characteristics among patients with ACAIAC. CCTA may therefore contribute to distinguish patients at risk of adverse events. (orig.)

  9. Age-related incidence of pulmonary embolism and additional pathologic findings detected by computed tomography pulmonary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Groth, M., E-mail: groth.michael@googlemail.com [Center for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Henes, F.O., E-mail: f.henes@uke.uni-hamburg.de [Center for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Mayer, U., E-mail: mayer@uke.uni-hamburg.de [Emergency Department, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Regier, M., E-mail: m.regier@uke.uni-hamburg.de [Center for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Adam, G., E-mail: g.adam@uke.uni-hamburg.de [Center for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Begemann, P.G.C., E-mail: p.begemann@me.com [Center for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany)

    2012-08-15

    Objective: To compare the incidence of pulmonary embolism (PE) and additional pathologic findings (APF) detected by computed tomography pulmonary angiography (CTPA) according to different age-groups. Materials and methods: 1353 consecutive CTPA cases for suspected PE were retrospectively reviewed. Patients were divided into seven age groups: {<=}29, 30-39, 40-49, 50-59, 60-69, 70-79 and {>=}80 years. Differences between the groups were tested using Fisher's exact or chi-square test. A p-value < 0.0024 indicated statistical significance when Bonferroni correction was used. Results: Incidence rates of PE ranged from 11.4% to 25.4% in different age groups. The three main APF were pleural effusion, pneumonia and pulmonary nodules. No significant difference was found between the incidences of PE in different age groups. Furthermore, APF in different age groups revealed no significant differences (all p-values > 0.0024). Conclusion: The incidences of PE and APF detected by CTPA reveal no significant differences between various age groups.

  10. Computed tomography and angiography do not reliably discriminate malignant meningiomas from benign ones

    International Nuclear Information System (INIS)

    Servo, A.; Porras, M.; Jaeaeskelaeinen, J.; Paetau, A.; Haltia, M.

    1990-01-01

    Histological anaplasia, found in up to 10% of meningiomas, is an important prognostic sign as it is associated with increased recurrence rate and volume growth rate. We studied in retrospect a series of 230 primary intracranial meningiomas to discover whether histological anaplasia can be reliably foreseen in CT scans and angiograms. 205 meningiomas were histologically benign, and 25 meningiomas were classified as malignant (atypical or anaplastic), with either incipient (20) or overt (5) signs of anaplasia. Of ten CT parameters tested, three were associated significantly more often with malignant meningiomas: Nodular contour (58.3% vs 26.7%); cysts (20.0% vs 4.4%) and absence of calcifications (92% vs 65.3%); none of these parameters was an absolute sign of anaplasia. 'Mushrooming', previously regarded as a definite sign of malignancy, was seen in 9% of benign meningiomas and in 21% of malignant ones. In angiography, no apparent differences between benign and malignant meningiomas were seen. The conclusion is that it is not possible to distinguish malignant meningiomas from benign ones with CT or angiography. (orig.)

  11. Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration

    International Nuclear Information System (INIS)

    Hwang, Jae-Yeon; Choo, Ki Seok; Choi, Yoon Young; Kim, Jin Hyeok; Ryu, Hwaseong; Kim, Yong-Woo; Jeon, Ung Bae; Nam, Kyung Jin; Han, Junhee

    2017-01-01

    Several recent studies showed the optimal contrast enhancement with a low-concentration and iso-osmolar contrast media in both adult and pediatric patients. However, low contrast media concentrations are not routinely used due to concerns of suboptimal enhancement of cardiac structures and small vessels. To evaluate the feasibility of using iso-osmolar contrast media containing a low iodine dose for CT cardiac angiography at 80 kilovolts (kVp) in neonates and infants. The iodixanol 270 group consisted of 79 CT scans and the iopromide 370 group of 62 CT scans in patients ≤1 year old. Objective measurement of the contrast enhancement was analyzed and contrast-to-noise ratios of the ascending aorta and left ventricle were calculated. Regarding subjective measurement, a four-point scale system was devised to evaluate degrees of contrast enhancement, image noise, motion artifact and overall image quality of each image set. Reader performance for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment was evaluated. Group objective and subjective measurements were nonsignificantly different. Overall sensitivity, specificity and diagnostic accuracy for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment were 42.8%, 59%, and 50%, respectively. The application of iodixanol 270 achieved optimal enhancement for performing pediatric cardiac CT angiography at 80 kVp in neonates and infants. Objective measurements of contrast enhancement and subjective image quality assessments were not statistically different in the iodixanol 270 and iopromide 370 groups. (orig.)

  12. Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae-Yeon [Pusan National University Yangsan Hospital, Department of Radiology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Pusan National University Yangsan Hospital, Research Institute for Convergence of Biomedical Science and Technology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Choo, Ki Seok; Choi, Yoon Young; Kim, Jin Hyeok; Ryu, Hwaseong; Kim, Yong-Woo; Jeon, Ung Bae; Nam, Kyung Jin [Pusan National University Yangsan Hospital, Department of Radiology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Han, Junhee [Pusan National University Yangsan Hospital, Division of Biostatistics, Research Institute for Convergence of Biomedical Science and Technology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of)

    2017-05-15

    Several recent studies showed the optimal contrast enhancement with a low-concentration and iso-osmolar contrast media in both adult and pediatric patients. However, low contrast media concentrations are not routinely used due to concerns of suboptimal enhancement of cardiac structures and small vessels. To evaluate the feasibility of using iso-osmolar contrast media containing a low iodine dose for CT cardiac angiography at 80 kilovolts (kVp) in neonates and infants. The iodixanol 270 group consisted of 79 CT scans and the iopromide 370 group of 62 CT scans in patients ≤1 year old. Objective measurement of the contrast enhancement was analyzed and contrast-to-noise ratios of the ascending aorta and left ventricle were calculated. Regarding subjective measurement, a four-point scale system was devised to evaluate degrees of contrast enhancement, image noise, motion artifact and overall image quality of each image set. Reader performance for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment was evaluated. Group objective and subjective measurements were nonsignificantly different. Overall sensitivity, specificity and diagnostic accuracy for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment were 42.8%, 59%, and 50%, respectively. The application of iodixanol 270 achieved optimal enhancement for performing pediatric cardiac CT angiography at 80 kVp in neonates and infants. Objective measurements of contrast enhancement and subjective image quality assessments were not statistically different in the iodixanol 270 and iopromide 370 groups. (orig.)

  13. Evaluation of right atrium-to-right ventricle diameter ratio on computed tomography pulmonary angiography: Prediction of adverse outcome and 30-day mortality.

    Science.gov (United States)

    Oz, Ibrahim Ilker; Altınsoy, Bülent; Serifoglu, Ismail; Sayın, Rasit; Buyukuysal, Mustafa Cagatay; Erboy, Fatma; Akduman, Ece Isin

    2015-12-01

    The aim of this study was to examine the association between right atrium (RA) and right ventricle (RV) diameters on computed tomography (CT) pulmonary angiography in response to acute pulmonary embolism (APE), in addition to 30-day mortality and adverse outcomes in patients with APE. This retrospective study was accepted by the institutional ethics committee. From January 2013 to March 2014, 79 hospitalized adult patients with symptomatic APE were included. Inclusion criteria were a CT pulmonary angiography positive for pulmonary embolism, availability of patient records, and a follow-up of at least 30 days. A review of patient records and images was performed. The maximum diameters of the heart chambers were measured on a reconstructed four-chamber heart view, and the vascular obstruction index was calculated on CT pulmonary angiography. There were statistically significant relationships in both the RA/RV diameter ratio and the RV/left ventricle (LV) diameter ratio between patients with and without adverse outcomes (prights reserved.

  14. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Christoph J., E-mail: c.jensen@contilia.d [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Jochims, Markus [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Hunold, Peter; Forsting, Michael; Barkhausen, Joerg [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany); Sabin, Georg V.; Bruder, Oliver [Department of Cardiology and Angiology, Elisabeth Hospital, Essen (Germany); Schlosser, Thomas [Department of Diagnostic and Interventional Radiology and Neuroradiology, University of Essen (Germany)

    2010-06-15

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 {+-} 8% vs. 64 {+-} 8%, p = 0.47; EDV 136 {+-} 36 ml vs. 138 {+-} 35 ml, p = 0.66; ESV 52 {+-} 21 ml vs. 52 {+-} 22 ml, p = 0.61; SV 83 {+-} 22 ml vs. 87 {+-} 19 ml, p = 0.22; CO 5.4 {+-} 0.9 l/min vs. 5.7 {+-} 1.2 l/min, p = 0.09, LVM 132 {+-} 33 g vs. 132 {+-} 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 {+-} 8% vs. 62 {+-} 9%; SV 73 {+-} 17 ml vs. 81 {+-} 15 ml; CO 5.7 {+-} 1.2 l/min vs. 5.0 {+-} 0.8 l/min; ESV 52 {+-} 27 ml vs. 57 {+-} 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 {+-} 31 g vs. 132 {+-} 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  15. Assessment of left ventricular function and mass in dual-source computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Jensen, Christoph J.; Jochims, Markus; Hunold, Peter; Forsting, Michael; Barkhausen, Joerg; Sabin, Georg V.; Bruder, Oliver; Schlosser, Thomas

    2010-01-01

    Purpose: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). Methods: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. Results.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63 ± 8% vs. 64 ± 8%, p = 0.47; EDV 136 ± 36 ml vs. 138 ± 35 ml, p = 0.66; ESV 52 ± 21 ml vs. 52 ± 22 ml, p = 0.61; SV 83 ± 22 ml vs. 87 ± 19 ml, p = 0.22; CO 5.4 ± 0.9 l/min vs. 5.7 ± 1.2 l/min, p = 0.09, LVM 132 ± 33 g vs. 132 ± 33 g, p = 0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59 ± 8% vs. 62 ± 9%; SV 73 ± 17 ml vs. 81 ± 15 ml; CO 5.7 ± 1.2 l/min vs. 5.0 ± 0.8 l/min; ESV 52 ± 27 ml vs. 57 ± 24 ml, all p < 0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177 ± 31 g vs. 132 ± 33 g, p < 0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. Conclusion: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.

  16. Volumetric Single-Beat Coronary Computed Tomography Angiography: Relationship of Image Quality, Heart Rate, and Body Mass Index. Initial Patient Experience With a New Computed Tomography Scanner.

    Science.gov (United States)

    Latif, Muhammad Aamir; Sanchez, Frank W; Sayegh, Karl; Veledar, Emir; Aziz, Muhammad; Malik, Rehan; Haider, Imran; Agatston, Arthur S; Batlle, Juan C; Janowitz, Warren; Peña, Constantino; Ziffer, Jack A; Nasir, Khurram; Cury, Ricardo C

    2016-01-01

    Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and

  17. Optimizing computed tomography pulmonary angiography using right atrium bolus monitoring combined with spontaneous respiration

    Energy Technology Data Exchange (ETDEWEB)

    Min, Wang; Jian, Li; Rui, Zhai [Jining No. 1 People' s Hospital, Department of Computed Tomography, Jining City, ShanDong Province (China); Wen, Li [Jining No. 1 People' s Hospital, Department of Gastroenterology, Jining, ShanDong (China); Dai, Lun-Hou [Shandong Chest Hospital, Department of Radiology, Jinan, ShanDong (China)

    2015-09-15

    CT pulmonary angiography (CTPA) aims to provide pulmonary arterial opacification in the absence of significant pulmonary venous filling. This requires accurate timing of the imaging acquisition to ensure synchronization with the peak pulmonary artery contrast concentration. This study was designed to test the utility of right atrium (RA) monitoring in ensuring optimal timing of CTPA acquisition. Sixty patients referred for CTPA were divided into two groups. Group A (n = 30): CTPA was performed using bolus triggering from the pulmonary trunk, suspended respiration and 70 ml of contrast agent (CA). Group B (n = 30): CTPA image acquisition was triggered using RA monitoring with spontaneous respiration and 40 ml of CA. Image quality was compared. Subjective image quality, average CT values of pulmonary arteries and density difference between artery and vein pairs were significantly higher whereas CT values of pulmonary veins were significantly lower in group B (all P < 0.05). There was no significant difference between the groups in the proportion of subjects where sixth grade pulmonary arteries were opacified (P > 0.05). RA monitoring combined with spontaneous respiration to trigger image acquisition in CTPA produces optimal contrast enhancement in pulmonary arterial structures with minimal venous filling even with reduced doses of CA. (orig.)

  18. Computed tomography angiography intraluminal filling defect is predictive of internal carotid artery free-floating thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Jaberi, A.; Lum, C.; Stefanski, P.; Iancu, D. [University of Ottawa, Faculty of Medicine, Ottawa, Ontario (Canada); The Ottawa Hospital, Department of Radiology, Neuroradiology Section, Ottawa, Ontario (Canada); Thornhill, R. [Neurosciences and Clinical Epidemiology Program/Methods Centre, Ottawa Hospital Research Institute, Ottawa, Ontario (Canada); The Ottawa Hospital, Department of Radiology, Neuroradiology Section, Ottawa, Ontario (Canada); Petrcich, W. [Neurosciences and Clinical Epidemiology Program/Methods Centre, Ottawa Hospital Research Institute, Ottawa, Ontario (Canada); Momoli, F. [Children' s Hospital of Eastern Ontario Research Institute, Ottawa, Ontario (Canada); University of Ottawa, Department of Epidemiology and Community Medicine, Ottawa, Ontario (Canada); Torres, C.; Dowlatshahi, D. [University of Ottawa, Faculty of Medicine, Ottawa, Ontario (Canada); University of Ottawa, Division of Neurology, Department of Medicine, Ottawa, Ontario (Canada)

    2014-01-15

    Filling defects at the internal carotid artery (ICA) origin in the work-up of stroke or transient ischemic attack may be an ulcerated plaque or free-floating thrombus (FFT). This may be challenging to distinguish, as they can appear morphologically similar. This is an important distinction as FFT can potentially embolize distally, and its management differs. We describe a series of patients with suspected FFT and evaluate its imaging appearance, clinical features, and evolution with therapy. Between 2008 and 2013, we prospectively collected consecutive patients with proximal ICA filling defects in the axial plane surrounded by contrast on CT/MR angiography. We defined FFT as a filling defect that resolved on follow-up imaging. We assessed the cranial-caudal dimension of the filling defect and receiver operating characteristics to identify clinical and radiological variables that distinguished FFT from complex ulcerated plaque. Intraluminal filling defects were identified in 32 patients. Filling defects and resolved or decreased in 25 patients (78 %) and felt to be FFT; there was no change in 7 (22 %). Resolved defects and those that decreased in size extended more cranially than those that remained unchanged: 7.3 mm (4.2-15.9) versus 3.1 mm (2.7-3.7; p = 0.0038). Receiver operating characteristic analysis established a threshold of 3.8 mm (filling defect length), sensitivity of 88 %, specificity of 86 %, and area under the curve of 0.86 (p < 0.0001) for distinguishing FFT from plaque. Filling defects in the proximal ICA extending cranially >3.8 mm were more likely to be FFT than complex ulcerated plaque. Further studies evaluating filling defect length as a predictor for FFT are warranted. (orig.)

  19. Arterial anomalies of the celiac trunk and median arcuate ligament compression in dogs and cats assessed by computed tomography angiography.

    Science.gov (United States)

    Le Pommellet, Hélène M; Scansen, Brian A; Mathys, Dimitria A; Mollenkopf, Dixie F; Reeves, Lauren; Skinas, Melissa L; Patel, Mira

    2018-02-01

    To identify abnormalities of the celiac artery (CA) and major branches in dogs and cats by computed tomography angiography (CTA). Multi-institutional retrospective case series. Two hundred fifty-four dogs and 13 cats. Abdominal CTA images from 2009 to 2017 were reviewed. Logistic regression models were used to evaluate the relationship between CA abnormalities and sex, age, size of dog, concurrent venous anomaly, or presence of gastrointestinal signs. Abnormalities in the CA were observed in 32 animals (11.9%) including 9 with abnormal branching (3.4%) and 23 with CA compression (8.6%). A celiacomesenteric trunk was observed in 8 (2.9%; 6 dogs, 2 cats). The splenic artery originated from the cranial mesenteric artery in 1 dog; the hepatic arterial branches originated from the left gastric artery in another. Four out of 32 animals (12.5%) with an arterial anomaly had another vascular abnormality. Large breed dogs were more likely to have an arterial anomaly (OR 4.3, 95% CI: 1.18-15.5, P = .02) and 12 times more likely to have CA compression (OR 12.0, 95% CI: 1.4-97.7, P = .02) compared to small breed dogs. Dogs with CA compression were more likely to present for gastrointestinal signs (OR 3.6, 95% CI: 1.2-10.3, P = .01). Anomalies of the celiac trunk are apparent on CTA and may impact surgical or image-guided intervention. Compression at the origin of the CA was apparent on imaging, similar to the median arcuate ligament syndrome in people, although the significance of this finding in dogs is unknown. © 2017 The American College of Veterinary Surgeons.

  20. Clinical and echocardiographic findings of patients with suspected acute pulmonary thromboembolism who underwent computed tomography pulmonary angiography

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2016-01-01

    Full Text Available Background: The aim of the study was to determine the correlation between clinical and echocardiographic findings and risk factors of patients with suspected acute pulmonary thromboembolism (PTE who underwent computed tomography pulmonary angiography (CTPA. Materials and Methods: In this cross-sectional study, 310 hospitalized patients aged >18 years with high clinical suspicion of PTE referred to imaging center of our hospital from different wards for CTPA were enrolled. The frequency of different clinical presentations, risk factors, items of Wells' criteria, and echocardiographic findings was compared in patients with and without PTE, which have been diagnosed according to the CTPA results. Results: PTE was diagnosed in 53 (17.1% of patients with suspected PTE. From clinical manifestations, tachypnea, pleuritic chest pain, and edema of lower extremities were significantly more frequent among patients with PTE (P < 0.05. Major surgery was the risk factor which was significantly more prevalent among patients with PTE (P < 0.05. Frequency of all criteria of Wells' criteria, except hemoptysis, was significantly higher in patients with PTE (P < 0.05. The frequency of all studied echocardiographic variables was significantly higher in patients with PTE (P < 0.05. Conclusion: It is suggested that we could use the results of this study for utilizing the diagnostic process of PTE in patients with highly clinical suspicion of PTE and providing more validated decision. Using the results of this study, we could identify high-risk patients and made appropriate risk assessment for better management of patients with suspected PTE as well as reduce the rate of unnecessary CTPA and its related adverse consequences.

  1. Optimal measurement for "posterolateral protrusion" of the vertebral artery at the craniovertebral junction using computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Junichi Ohya

    2014-01-01

    Full Text Available Purpose: Among extraosseous abnormalities of the vertebral artery (VA at the craniovertebral junction (CVJ, available evidence regarding "posterolateral protrusion," the VA running distant from the groove over the superior surface of the posterior arch of the atlas, is limited. The purpose of this study was to determine the optimal measurement to indicate posterolateral protrusion of the VA. Materials and Methods: Computed tomography angiography (CTA images of 40 consecutive patients with cervical disease were reviewed. Ultimately, 66 arteries were included in this study. Five parameters predicted to indicate posterolateral protrusion of the VA were defined (A-E and measured by two surgeons twice over a 2-week interval. Intraclass correlation coefficients (ICC were used to examine intra-observer reproducibility and inter-observer reliability. Receiver operating characteristic (ROC curve analysis was performed to determine the most optimal parameter to predict posterolateral protrusion of the VA. Results: Excellent inter-observer reliability and intra-observer reproducibility were obtained for all parameters (ICC = 0.87-0.99. Among them, parameter A, defined as the maximal length from the outer surface of the VA to the outer surface of the posterior arch of the atlas, was most accurately described posterolateral protrusion of the VA. The optimal cut-off value of parameter A obtained with ROC curves was 8.3 mm (sensitivity 97.5%, specificity 100%. Conclusions: The measurement in this study can quantitatively evaluate the posterolateral protrusion of the VA. Before posterior surgery at the CVJ, pre-operative CTA can help surgeons detect anomalous VA and reduce the risk of intra-operative VA injury.

  2. Lower extremity computed tomography angiography can help predict technical success of endovascular revascularization in the superficial femoral and popliteal artery.

    Science.gov (United States)

    Itoga, Nathan K; Kim, Tanner; Sailer, Anna M; Fleischmann, Dominik; Mell, Matthew W

    2017-09-01

    Preprocedural computed tomography angiography (CTA) assists in evaluating vascular morphology and disease distribution and in treatment planning for patients with lower extremity peripheral artery disease (PAD). The aim of the study was to determine the predictive value of radiographic findings on CTA and technical success of endovascular revascularization of occlusions in the superficial femoral artery-popliteal (SFA-pop) region. Medical records and available imaging studies were reviewed for patients undergoing endovascular intervention for PAD between January 2013 and December 2015 at a single academic institution. Radiologists reviewed preoperative CTA scans of patients with occlusions in the SFA-pop region. Radiographic criteria previously used to evaluate chronic occlusions in the coronary arteries were used. Technical success, defined as restoration of inline flow through the SFA-pop region with technical failure (P = .014). Longer lengths of occlusion were also associated with technical failure (P = .042). Multiple occlusions (P = .55), negative remodeling (P = .69), vessel runoff (P = .56), and percentage of vessel calcification (P = .059) were not associated with failure. On multivariable analysis, 100% calcification remained the only significant predictor of technical failure (odds ratio, 9.0; 95% confidence interval, 1.8-45.8; P = .008). Analysis of preoperative CTA shows 100% calcification as the best predictor of technical failure of endovascular revascularization of occlusions in the SFA-pop region. Further studies are needed to determine the cost-effectiveness of obtaining preoperative CTA for lower extremity PAD. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. TH-CD-206-12: Image-Based Motion Estimation for Plaque Visualization in Coronary Computed Tomography Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X; Sisniega, A; Zbijewski, W; Stayman, J [Johns Hopkins University, Balitmore, MD (United States); Contijoch, F; McVeigh, E [University of California, San Diego, San Diego, CA (United States)

    2016-06-15

    Purpose: Visualization and quantification of coronary artery calcification and atherosclerotic plaque benefits from coronary artery motion (CAM) artifact elimination. This work applies a rigid linear motion model to a Volume of Interest (VoI) for estimating motion estimation and compensation of image degradation in Coronary Computed Tomography Angiography (CCTA). Methods: In both simulation and testbench experiments, translational CAM was generated by displacement of the imaging object (i.e. simulated coronary artery and explanted human heart) by ∼8 mm, approximating the motion of a main coronary branch. Rotation was assumed to be negligible. A motion degraded region containing a calcification was selected as the VoI. Local residual motion was assumed to be rigid and linear over the acquisition window, simulating motion observed during diastasis. The (negative) magnitude of the image gradient of the reconstructed VoI was chosen as the motion estimation objective and was minimized with Covariance Matrix Adaptation Evolution Strategy (CMAES). Results: Reconstruction incorporated the estimated CAM yielded signification recovery of fine calcification structures as well as reduced motion artifacts within the selected local region. The compensated reconstruction was further evaluated using two image similarity metrics, the structural similarity index (SSIM) and Root Mean Square Error (RMSE). At the calcification site, the compensated data achieved a 3% increase in SSIM and a 91.2% decrease in RMSE in comparison with the uncompensated reconstruction. Conclusion: Results demonstrate the feasibility of our image-based motion estimation method exploiting a local rigid linear model for CAM compensation. The method shows promising preliminary results for the application of such estimation in CCTA. Further work will involve motion estimation of complex motion corrupted patient data acquired from clinical CT scanner.

  4. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound.

    Science.gov (United States)

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Spiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin; Rużyłło, Witold; Kępka, Cezary

    2013-01-01

    Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Two hundred and fifty-two calcified lesions within 97 arteries of 60 patients (19 women, age 63 ±10 years) underwent assessment with both 2 × 64 slice CT (Somatom Definition, Siemens) and IVUS (s5, Volcano Corp.). Coronary lumen and calcium dimensions within calcified lesions were assessed with CTCA and compared to the reference measurements made with IVUS. On average CTCA underestimated mean lumen diameter (2.8 ±0.7 mm vs. 2.9 ±0.8 mm for IVUS), lumen area (6.4 ±3.4 mm(2) vs. 7.0 ±3.7 mm(2) for IVUS, p < 0.001) and total calcium arc (52 ±35° vs. 83 ±54°). However, analysis of tertiles of the examined parameters revealed that the mean lumen diameter, lumen area and calcium arc did not significantly differ between CTCA and IVUS within the smallest lumens (1(st) tertile of mean lumen diameter at 2.1 mm, and 1(st) tertile of lumen area at 3.7 mm(2)) and lowest calcium arc (mean of 40°). Although, on average, CTCA underestimates lumen diameter and area as well as calcium arc within calcified lesions, the differences are not significant within the smallest vessels and calcium arcs. The low diagnostic accuracy of CTCA within calcified lesions may be attributed to high variance and not to systematic error of measurements.

  5. Prevalence and diagnostic performance of computed tomography angiography spot sign for intracerebral hematoma expansion depend on scan timing

    Energy Technology Data Exchange (ETDEWEB)

    Tsukabe, Akio; Watanabe, Yoshiyuki; Tanaka, Hisashi; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Suita, Osaka (Japan)

    2014-12-15

    The computed tomography angiography (CTA) spot sign correlates with intracerebral hemorrhage (ICH) expansion; however, various diagnostic performances for hematoma expansion, especially in sensitivity, have been reported. We aimed to assess the impact of scan timing of CTA on the diagnostic performance of the CTA spot sign for ICH expansion in two different arterial phases within patients. Eighty-three consecutive patients with primary ICH who received two sequential CTAs were recruited. Two neuroradiologists reviewed CTAs for CTA spot signs, while one reviewed initial and follow-up non-contrast CT for measuring ICH volume. The time interval between two phases was then calculated, and the diagnostic performance of CTA spot sign in each phase was evaluated. CTA spot signs were observed in 20/83 (24.1 %) patients in the early phase and 44/83 (53.0 %) patients in the late phase. The mean time interval between the two phases was 12.7 s. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for hematoma progression of CTA spot sign were 48.1, 87.5, 65.0, 77.8, and 74.7 %, respectively, in early phase and 92.6, 66.1, 56.8, 94.9, and 74.7 %, respectively, in late phase. The CTA spot sign was significantly associated with ICH expansion in early (P < 0.001) and late (P < 0.00001) phases (Pearson's chi-square test). A mere 10-s difference in scan timing could make a difference on prevalence and diagnostic performance of the CTA spot sign, suggesting a need for the standardization of the CTA protocol to generalize the approach for effective clinical application. (orig.)

  6. Imaging of the Coronary Venous System: Validation of Three-Dimensional Rotational Venous Angiography Against Dual-Source Computed Tomography

    International Nuclear Information System (INIS)

    Knackstedt, Christian; Muehlenbruch, Georg; Mischke, Karl; Bruners, Philipp; Schimpf, Thomas; Frechen, Dirk; Schummers, Georg; Mahnken, Andreas H.; Guenther, Rolf W.; Kelm, Malte; Schauerte, Patrick

    2008-01-01

    Information on the anatomy of the cardiac venous system (CVS) is increasingly important for cardiac resynchronization therapy or percutaneous transvenous mitral valve annuloplasty. Three-dimensional (3D) imaging can further improve the understanding of the relationship of cardiac structures. This study was performed to validate the accuracy of rotational coronary sinus angiography (CSA) displaying the 3D anatomy of the CVS compared to ECG-gated, contrast-enhanced, cardiac dual-source computed tomography (DSCT). Five domestic pigs (60 kg) underwent DSCT using a standardized examination protocol. Using a standard C-arm for fluoroscopy, a rotational CSA was obtained and 3D-image reconstructions performed. Side branches were identified using both methods and enumerated. Vessel visibility was estimated for each side branch and great cardiac vein/anterior interventricular vein. Also, vessel diameters were measured at distinct landmarks, i.e., side branching. The amount of contrast medium was determined and the effective radiation exposure of both methods was calculated. There was no significant difference regarding the vessel diameter of the great cardiac vein/anterior interventricular vein or its side branches. Also, estimation of vessel visibility was not different between the two imaging modalities. Estimated radiation exposure and amount of contrast medium were lower for rotational CSA. In conclusion, a 3D reconstruction of rotational CSA images is possible. All parts of the CVS are well depicted, allowing a 3D overview of the CVS anatomy. On-site 3D visualization might improve decision making during cardiac interventions. In contrast to DSCT, rotational CSA does not demonstrate the anatomy of the mitral annulus or the course of the left circumflex artery.

  7. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  8. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Precht, H.; Kitslaar, P.H.; Broersen, A.; Gerke, O.; Dijkstra, J.; Thygesen, J.; Egstrup, K.; Lambrechtsen, J.

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model-based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) images on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods: Three patients had three independent dose reduced CCTA performed and reconstructed with 30% ASIR (CTDI vol at 6.7 mGy), 60% ASIR (CTDI vol 4.3 mGy) and Veo (CTDI vol at 1.9 mGy). Coronary plaque analysis was performed for each measured CCTA volumes, plaque burden and intensities. Results: Plaque volume and plaque burden show a decreasing tendency from ASIR to Veo as median volume for ASIR is 314 mm 3 and 337 mm 3 –252 mm 3 for Veo and plaque burden is 42% and 44% for ASIR to 39% for Veo. The lumen and vessel volume decrease slightly from 30% ASIR to 60% ASIR with 498 mm 3 –391 mm 3 for lumen volume and vessel volume from 939 mm 3 to 830 mm 3 . The intensities did not change overall between the different reconstructions for either lumen or plaque. Conclusion: We found a tendency of decreasing plaque volumes and plaque burden but no change in intensities with the use of low dose Veo CCTA (1.9 mGy) compared to dose reduced ASIR CCTA (6.7 mGy & 4.3 mGy), although more studies are warranted. - Highlights: • Veo decrease plaque volumes and plaque burden using low-dose CCTA. • Moving from ASIR 30%, ASIR 60% to Veo did not appear to influence the plaque intensities. • Studies including larger sample size are needed to investigate the effect on plaque.

  9. Stereoscopic Vascular Models of the Head and Neck: A Computed Tomography Angiography Visualization

    Science.gov (United States)

    Cui, Dongmei; Lynch, James C.; Smith, Andrew D.; Wilson, Timothy D.; Lehman, Michael N.

    2016-01-01

    Computer-assisted 3D models are used in some medical and allied health science schools; however, they are often limited to online use and 2D flat screen-based imaging. Few schools take advantage of 3D stereoscopic learning tools in anatomy education and clinically relevant anatomical variations when teaching anatomy. A new approach to teaching…

  10. Usefulness of preoperative coronary angiography and brain computed tomography in cases of coronary artery disease and cerebrovascular disease undergoing revascularization for arteriosclerosis obliterans

    International Nuclear Information System (INIS)

    Sakurada, Tall; Shibata, Yoshiki

    2003-01-01

    Coronary angiography and brain computed tomography were preoperatively performed to evaluate the clinical condition of coronary artery disease and cerebrovascular disease in 101 patients (mean age, 68.4 years) with revascularization for arteriosclerosis obliterans. Eighty patients had hypertension, 12 had diabetes, and 26 had hyperlipidemia. Seventy-one patients (70.3%) had coronary stenosis. Significant stenoses in major coronary artery branches were confirmed in 35 patients, including 13 patients with old myocardial infarction. Coronary artery bypass grafting and percutaneous coronary angioplasty were performed in 2 and 7 patients with critical stenosis, respectively. Of 57 patients, who underwent brain computed tomography, abnormalities were found in 52 patients (91.2%), including cortical infarction in 9, lacunar infarction in 35, and leukoaraiosis in 27 patients. During the follow-up period 13 patients died (including 3 cases of myocardial infarction and 3 cases of stroke). Actuarial survival rate at 5 years was 80.4%. The influence of ischemic heart disease and cerebrovascular disease on early and late mortality after surgical reconstruction for peripheral occlusive vascular disease is significant. Using visual diagnostic techniques, such as coronary angiography and brain computed tomography, long term survivor should be closely observed for multiple arteriosclerotic vascular diseases. (author)

  11. Usefulness of preoperative coronary angiography and brain computed tomography in cases of coronary artery disease and cerebrovascular disease undergoing revascularization for arteriosclerosis obliterans

    Energy Technology Data Exchange (ETDEWEB)

    Sakurada, Tall; Shibata, Yoshiki [Southern Tohoku Fukushima Hospital (Japan)

    2003-05-01

    Coronary angiography and brain computed tomography were preoperatively performed to evaluate the clinical condition of coronary artery disease and cerebrovascular disease in 101 patients (mean age, 68.4 years) with revascularization for arteriosclerosis obliterans. Eighty patients had hypertension, 12 had diabetes, and 26 had hyperlipidemia. Seventy-one patients (70.3%) had coronary stenosis. Significant stenoses in major coronary artery branches were confirmed in 35 patients, including 13 patients with old myocardial infarction. Coronary artery bypass grafting and percutaneous coronary angioplasty were performed in 2 and 7 patients with critical stenosis, respectively. Of 57 patients, who underwent brain computed tomography, abnormalities were found in 52 patients (91.2%), including cortical infarction in 9, lacunar infarction in 35, and leukoaraiosis in 27 patients. During the follow-up period 13 patients died (including 3 cases of myocardial infarction and 3 cases of stroke). Actuarial survival rate at 5 years was 80.4%. The influence of ischemic heart disease and cerebrovascular disease on early and late mortality after surgical reconstruction for peripheral occlusive vascular disease is significant. Using visual diagnostic techniques, such as coronary angiography and brain computed tomography, long term survivor should be closely observed for multiple arteriosclerotic vascular diseases. (author)

  12. Direct costs and cost-effectiveness of dual-source computed tomography and invasive coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease.

    Science.gov (United States)

    Dorenkamp, Marc; Bonaventura, Klaus; Sohns, Christian; Becker, Christoph R; Leber, Alexander W

    2012-03-01

    The study aims to determine the direct costs and comparative cost-effectiveness of latest-generation dual-source computed tomography (DSCT) and invasive coronary angiography for diagnosing coronary artery disease (CAD) in patients suspected of having this disease. The study was based on a previously elaborated cohort with an intermediate pretest likelihood for CAD and on complementary clinical data. Cost calculations were based on a detailed analysis of direct costs, and generally accepted accounting principles were applied. Based on Bayes' theorem, a mathematical model was used to compare the cost-effectiveness of both diagnostic approaches. Total costs included direct costs, induced costs and costs of complications. Effectiveness was defined as the ability of a diagnostic test to accurately identify a patient with CAD. Direct costs amounted to €98.60 for DSCT and to €317.75 for invasive coronary angiography. Analysis of model calculations indicated that cost-effectiveness grew hyperbolically with increasing prevalence of CAD. Given the prevalence of CAD in the study cohort (24%), DSCT was found to be more cost-effective than invasive coronary angiography (€970 vs €1354 for one patient correctly diagnosed as having CAD). At a disease prevalence of 49%, DSCT and invasive angiography were equally effective with costs of €633. Above a threshold value of disease prevalence of 55%, proceeding directly to invasive coronary angiography was more cost-effective than DSCT. With proper patient selection and consideration of disease prevalence, DSCT coronary angiography is cost-effective for diagnosing CAD in patients with an intermediate pretest likelihood for it. However, the range of eligible patients may be smaller than previously reported.

  13. Computed tomography angiography reveals stenosis and aneurysmal dilation of an aberrant right subclavian artery causing systemic blood pressure misreading in an old Pekinese dog.

    Science.gov (United States)

    Kim, Jaehwan; Eom, Kidong; Yoon, Hakyoung

    2017-06-16

    A 14-year-old dog weighing 4 kg presented with hypotension only in the right forelimb. Thoracic radiography revealed a round soft tissue opacity near the aortic arch and below the second thoracic vertebra on a lateral view. Three-dimensional computed tomography angiography clearly revealed stenosis and aneurysmal dilation of an aberrant right subclavian artery. Stenosis and aneurysm of an aberrant subclavian artery should be included as a differential diagnosis in dogs showing a round soft tissue opacity near the aortic arch and below the thoracic vertebra on the lateral thoracic radiograph.

  14. Prevalence of Coronary Artery Intramyocardial Course in a Large Population of Clinical Patients Detected by Multislice Computed Tomography Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    De Rosa, R.; Sacco, M.; Tedeschi, C.; Pepe, R.; Capogrosso, P.; Montemarano, E.; Rotondo, A.; Runza, G.; Midiri, M.; Cademartiri, F. (UO di Radiologia, Ospedale San Gennaro, Napoli (Italy))

    2008-10-15

    Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59+-6 years) with atypical chest pain admitted to our hospital between December 2004 and September 2006. All MDCT examinations were performed using a 16-detector-row scanner (Aquilion 16 CFX; Toshiba Medical System, Tokyo, Japan). Patients with heart rate above 65 bpm received 50 mg atenolol orally for 3 days prior to the MDCT scan, or they increased their usual therapy with beta-blockers, in order to obtain a prescan heart rate <60 bpm. Curved multiplanar and 3D volume reconstructions were performed to explore coronary anatomy. Results: In 235 patients, the CT scan was successful and images were appropriate for evaluation. The prevalence of myocardial bridging and intramyocardial course of coronary arteries was 18.7% (47 cases) in our patient population. In 30 segments (63.8%), the vessels ran and ended in the myocardium. In the remaining 17 segments (36.2%), the vessels returned to an epicardial position after the muscle bridge. We found no difference in the prevalence of this inborn coronary anomaly when comparing different clinical characteristics of the study population (sex, age, body-mass index [BMI], etc.). The mean length of the subepicardial artery was 7 mm (range 5-12 mm), and the mean depth in the diastolic phase was 1.9 mm (range 1.2-2.3 mm). There was no significant difference of

  15. Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B., E-mail: hinrichs.jan@mh-hannover.de; Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Falck, Christian von, E-mail: falck.christian.von@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany); Hoeper, Marius M., E-mail: hoeper.marius@mh-hannover.de; Olsson, Karen M., E-mail: olsson.karen@mh-hannover.de [Hannover Medical School, Clinic for Pneumology, German Center for Lung Research (DZL) (Germany); Wacker, Frank K., E-mail: wacker.frank@mh-hannover.de; Meyer, Bernhard C., E-mail: meyer.bernhard@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany)

    2016-01-15

    PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

  16. Congenital coronary artery anomalies: diagnosis with 64 slice multidetector row computed tomography coronary angiography: A single Centre Study

    International Nuclear Information System (INIS)

    Srnivasan, K.G.; Gaikward, A.; Kannan, B.R.J.; Ritesh, K.; Ushanandini, K.P.

    2008-01-01

    Full text: Retrospective review of the congenital coronary artery (CA) anomalies detected by a 64-slice multidetector row computed tomographic (MDCT) angiography. The type of the anomaly, imaging characteristics, clinical relevance and the superiority of the MDCT over conventional coronary angiography are discussed. Multidetector row computed tomographic coronary angiography was carried out by the usual technique with 70 cc of non-ionic contrast agent and retrospective electrocardiogram gating. The volume data obtained were reconstructed in axial plane, along with volume-rendered three-dimensional reconstruction and virtual angioscopy in selected patients. The images were analysed by a radiologist, experienced in cardiac CT, and an experienced cardiologist. A retrospective review of the records was carried out, and subjects with congenital coronary anomalies were included in the study. Between 15 November 2005 and 27 February 2007, 1495 MDCT coronary angiograms were carried out. Eleven of them were found to have coronary anomalies. Five had absent left main CA. Two had interarterial course of the left main CA artery passing in between the right ventricular outflow tract and the root of aorta. In one patient, there was aberrant origin of right CA from the left aortic sinus with subsequent interarterial course and another one had aberrant origin of circumflex artery from the right aortic sinus. One patient each of congenitally absent circumflex artery and atresia of the right CA were found. Sixty-four slice MDCT coronary angiography provided accurate depiction of anomalous vessel origin and course along with the complex anatomical relation with the adjacent structures. CTcan be considered as a first-line imaging method for delineating coronary arterial anomalies.

  17. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. [Dept. of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany)

    2007-04-15

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography.

  18. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    International Nuclear Information System (INIS)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2007-01-01

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography

  19. Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80 kV and iterative reconstruction algorithm using different concentration contrast media.

    Science.gov (United States)

    Annoni, Andrea Daniele; Mancini, Maria E; Andreini, Daniele; Formenti, Alberto; Mushtaq, Saima; Nobili, Enrica; Guglielmo, Marco; Baggiano, Andrea; Conte, Edoardo; Pepi, Mauro

    2017-10-01

    Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV. Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols. © 2017 The Royal Australian and New Zealand College of Radiologists.

  20. Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

    International Nuclear Information System (INIS)

    Struffert, Tobias; Ott, Sabine; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Doerfler, Arnd; Deuerling-Zheng, Yu

    2011-01-01

    Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents. (orig.)

  1. Computational fluid dynamics comparisons of wall shear stress in patient-specific coronary artery bifurcation using coronary angiography and optical coherence tomography

    Science.gov (United States)

    Poon, Eric; Thondapu, Vikas; Chin, Cheng; Scheerlinck, Cedric; Zahtila, Tony; Mamon, Chris; Nguyen, Wilson; Ooi, Andrew; Barlis, Peter

    2016-11-01

    Blood flow dynamics directly influence biology of the arterial wall, and are closely linked with the development of coronary artery disease. Computational fluid dynamics (CFD) solvers may be employed to analyze the hemodynamic environment in patient-specific reconstructions of coronary arteries. Although coronary X-ray angiography (CA) is the most common medical imaging modality for 3D arterial reconstruction, models reconstructed from CA assume a circular or elliptical cross-sectional area. This limitation can be overcome with a reconstruction technique fusing CA with intravascular optical coherence tomography (OCT). OCT scans the interior of an artery using near-infrared light, achieving a 10-micron resolution and providing unprecedented detail of vessel geometry. We compared 3D coronary artery bifurcation models generated using CA alone versus OCT-angiography fusion. The model reconstructed from CA alone is unable to identify the detailed geometrical variations of diseased arteries, and also under-estimates the cross-sectional vessel area compared to OCT-angiography fusion. CFD was performed in both models under pulsatile flow in order to identify and compare regions of low wall shear stress, a hemodynamic parameter directly linked with progression of atherosclerosis. Supported by ARC LP150100233 and VLSCI VR0210.

  2. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  3. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  4. Computed tomography in renal trauma

    International Nuclear Information System (INIS)

    Brueck, W.; Eisenberger, F.; Buck, J.

    1981-01-01

    In a group of 19 patients suffering from flank trauma and gross hematuria the diagnostic value of angiography was compared with that of computed tomography. The cases that underwent both tests were found to have the some diagnosis of rupture of the kidney. Typical CT-findings in kidney rupture are demonstrated. Whereas angiography presents an exact picture of the arterial system of the kidney, including its injures computed tomography reveals the extent of organ lesons by showing extra- and intrarenal hematomas. If surgery is planned angiography is still mandatory, whereby the indication is largely determined by the clinical findings. Computed tomography as a non-invasive method is equally suitable for follow-ups. (orig.) [de

  5. Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia M., E-mail: investigacion@diagnosticomaipu.com.ar; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López Munain, Marina de; Vallejos, Javier; Tajer, Carlos; Rodriguez-Granillo, Gaston A.

    2015-04-15

    Highlights: •We evaluated myocardial perfusion by dual energy computed tomography (DECT). •We included patients with intermediate to high likelihood of coronary artery disease. •Stress myocardial perfusion by DECT had a reliable accuracy for the detection of ischemia. •Stress myocardial perfusion with DECT showed an incremental value over anatomical evaluation. •DECT imaging was associated to a significant reduction in radiation dose compared to SPECT. -- Abstract: Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80–0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65–0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.

  6. Relationship of the duke jeopardy score combined with minimal lumen diameter as assessed by computed tomography angiography to the hemodynamic relevance of coronary artery stenosis.

    Science.gov (United States)

    Yu, Mengmeng; Zhao, Yonghong; Li, Wenbin; Lu, Zhigang; Wei, Meng; Zhou, Wenxiao; Zhang, Jiayin

    2018-03-02

    To study the diagnostic performance of the ratio between the Duke jeopardy score (DJS) and the minimal lumen diameter (MLD) (DJS/MLD CT ratio) as assessed by coronary computed tomographic angiography (CTA) for differentiating functionally significant from non-significant coronary artery stenoses, with reference to invasive fractional flow reserve (FFR). Patients who underwent both coronary CTA and FFR measurement during invasive coronary angiography (ICA) within 2 weeks were retrospectively included in the study. Invasive FFR measurement was performed in patients with intermediate to severe coronary stenoseis. DJS/MLD CT ratio and anatomical parameters were recorded. Lesions with FFR ≤0.80 were considered to be functionally significant. One hundred and sixty-one patients with 175 lesions were included into the analysis. Diameter stenosis in CT, area stenosis, plaque burden, lesion length (LL), ICA-based stenosis degree, DJS, LL/MLD 4 ratio, DJS/MLA ratio as well as DJS/MLD ratio were all significantly different between hemodynamically significant and non-significant lesions (pvalue for DJS/MLD CT ratio to be 1.96 (area under curve = 0.863, 95 % confidence interval = 0.803-0.910), yielding a high diagnostic accuracy (86.9%, 152/175). In coronary artery stenoses detected by coronary CTA, the DJS/MLD ratio is able to predict hemodynamic relevance. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  7. Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Cademartiri, Filippo; Krestin, Gabriel P.; Mollet, Nico R.; Feyter, Pim J. de; Runza, Giuseppe; Midiri, Massimo; Bruining, Nico; Hamers, Ronald; Somers, Pamela; Knaapen, Michiel; Verheye, Stefan

    2005-01-01

    Assessment of attenuation (measured in Hounsfield units, HU) of human coronary plaques was performed using multislice computed tomography (MSCT) in an ex vivo model. In three ex vivo specimens of left coronary arteries in oil, MSCT was performed after intracoronary injection of four solutions of contrast material (400 mgI/ml iomeprol). The four solutions were diluted as follows: 1/∞, 1/200, 1/80, and 1/20. All scans were performed with the following parameters: slices/collimation 16/0.75 mm, rotation time 375 ms. Each specimen was scored for the presence of atherosclerotic plaques. In each plaque the attenuation was measured in four regions of interest for lumen, plaque (non-calcified thickening of the vessel wall), calcium, and surrounding (oil surrounding the vessel). The results were compared with a one-way analysis of variance test and were correlated with Pearson's test. There were no significant differences in the attenuation of calcium and oil in the four solutions. The mean attenuation in the four solutions for lumen (35±10, 91±7, 246±18, 511±89 HU) and plaque (22±22, 50±26, 107±36, 152±67 HU) was significantly different between each decreasing dilution (p<0.001). The mean attenuation of lumen and plaque of coronary plaques showed high correlation, while the values were significantly different (r=0.73; p<0.001). Intracoronary attenuation modifies significantly the attenuation of plaques assessed with MSCT. (orig.)

  8. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  9. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    Science.gov (United States)

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  10. Non-invasive Heart Team assessment of multivessel coronary disease with coronary computed tomography angiography based on SYNTAX score II treatment recommendations: design and rationale of the randomised SYNTAX III Revolution trial

    NARCIS (Netherlands)

    Cavalcante, Rafael; Onuma, Yoshinobu; Sotomi, Yohei; Collet, Carlos; Thomsen, Brian; Rogers, Campbell; Zeng, Yaping; Tenekecioglu, Erhan; Asano, Taku; Miyasaki, Yosuke; Abdelghani, Mohammad; Morel, Marie-Angèle; Serruys, Patrick W.

    2017-01-01

    The aim of this study was to investigate whether a Heart Team decision-making process regarding the choice of revascularisation strategy based on non-invasive coronary multislice computed tomography angiography (MSCT) assessment of coronary artery disease (CAD) is equivalent to the standard-of-care

  11. Multidetector computed tomography angiography in clinically suspected hyperacute ischemic stroke in the anterior circulation: an etiological workup in a cohort of Brazilian patients

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2015-05-01

    Full Text Available Objective The potential of computed tomography angiography (CTA was assessed for early determination of stroke subtypes in a Brazilian cohort of patients with stroke. Method From July 2011 to July 2013, we selected patients with suspected hyperacute stroke (< 6 hours. Intracranial and cervical arteries were scrutinized on CTA and their imaging features were correlated with concurrent subtype of stroke. Results Stroke was documented in 50/106 selected patients (47.2% based on both clinical grounds and imaging follow-up (stroke group, with statistically significant arterial stenosis and vulnerable plaques on CTA. Intracranial large artery disease was demonstrated in 34% of patients in the stroke group. Partial territorial infarct prevailed (86% while artery-to-artery embolization was the most common stroke mechanism (52%. Conclusion Multidetector CTA was useful for the etiologic work-up of hyperacute ischemic stroke and facilitated the knowledge about the topographic pattern of brain infarct in accordance with its causative mechanism.

  12. Normal values of regional left ventricular myocardial thickness, mass and distribution-assessed by 320-detector computed tomography angiography in the Copenhagen General Population Study

    DEFF Research Database (Denmark)

    Hindsø, Louise; Fuchs, Andreas; Kühl, Jørgen Tobias

    2017-01-01

    regional normal reference values of the left ventricle. The aim of this study was to derive reference values of regional LV myocardial thickness (LVMT) and mass (LVMM) from a healthy study group of the general population using cardiac computed tomography angiography (CCTA). We wanted to introduce LV...... myocardial distribution (LVMD) as a measure of regional variation of the LVMT. Moreover, we wanted to determine whether these parameters varied between men and women. We studied 568 (181 men; 32%) adults, free of cardiovascular disease and risk factors, who underwent 320-detector CCTA. Mean age was 55 (range...... 40-84) years. Regional LVMT and LVMM were measured, according to the American Heart Association's 17 segment model, using semi-automatic software. Mean LVMT were 6.6 mm for men and 5.4 mm for women (p normal LV was thickest in the basal septum (segment 3; men = 8.3 mm; women = 7.2 mm...

  13. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  15. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  16. The value of coronary artery calcium score assessed by dual-source computed tomography coronary angiography for predicting presence and severity of coronary artery disease

    International Nuclear Information System (INIS)

    Almasi, Alireza; Pouraliakbar, Hamidreza; Sedghian, Ahmad; Karimi, Mohammad Ali; Firouzi, Ata; Tehrai, Mahmood

    2014-01-01

    Measuring coronary artery calcium score (CACS) using a dual-source CT scanner is recognized as a major indicator for assessing coronary artery disease. The present study aimed to validate the clinical significance of CACS in predicting coronary artery stenosis and its severity. This prospective study was conducted on 202 consecutive patients who underwent both conventional coronary angiography and dual-source (256-slice) computed tomography coronary angiography (CTA) for any reason in our cardiac imaging center from March to September 2013. CACS was measured by Agatston algorithm on non-enhanced CT. The severity of coronary artery disease was assessed by Gensini score on conventional angiography. There was a significant relationship between the number of diseased coronary vessels and mean calcium score, i.e. the mean calcium score was 202.25±450.06 in normal coronary status, 427.50±607.24 in single-vessel disease, 590.03±511.34 in two-vessel disease, and 953.35±1023.45 in three-vessel disease (p<0.001). There was a positive association between calcium score and Gensini score (r=0.636, p<0.001). In a linear regression model, calcium score was a strong determinant of the severity of coronary artery disease. Calcium scoring had an acceptable value for discriminating coronary disease from normal condition with optimal cutoff point of 350, yielding a sensitivity and specificity of 83% and 70%, respectively. Our study confirmed the strong relationship between the coronary artery calcium score and the presence and severity of stenosis in coronary arteries assessed by both the number of diseased coronary vessels and also by the Gnesini score

  17. The effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multislice computed tomography angiography

    International Nuclear Information System (INIS)

    Tuyyab, F.; Naeem, M.Y.; Maken, G.R.; Najfi, M.H.; Hassan, F.

    2012-01-01

    Objective: The purpose of this study was to determine the effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multi slice computed tomography (MSCT) angiography. Methodology: This was a Double blind randomized controlled trial was conducted at AFIC/NIHD, Rawalpindi, from May 2011 to November 2011. Patients undergoing first MSCT angiography meeting inclusion criteria with heart rates (HR) more than 80 beats/min were included. Patients were randomized in to two groups using random numbers table. Group 1 was administered metaprolol plus placebo while group 2 was administered metaprolol plus bromazepam one hour before the scan. Both groups had scans under strictly similar conditions. HR before and during scan along with heart rate variability (HRV) were recorded. Results: A total of 80 patients were included. Patients mean age was 49 + 13, 57 % were males while 43 % were females. Risk factor profile was similar in both groups. HR reduction in group 1 was 15+ 6.0 and in group 2, was 21+9.0 (p= 0.002). HRV in group 1 was 3.9 + 1.32 and in group 2 was 2.3 + 1.0 (p= 0.003). Group 2 had significantly lower HR and significantly less HRV as compared with group 1. Conclusion: Combination of bromazepam and metaprolol results in significant and further reduction in heart rate and heart rate variability than metaprolol alone. Both drugs can be used together for a better control of heart rate and heart rate variability during MSCT angiography for improving the quality of images. (author)

  18. Use of ECG-gated computed tomography, echocardiography and selective angiography in five dogs with pulmonic stenosis and one dog with pulmonic stenosis and aberrant coronary arteries.

    Science.gov (United States)

    Laborda-Vidal, P; Pedro, B; Baker, M; Gelzer, A R; Dukes-McEwan, J; Maddox, T W

    2016-12-01

    Pulmonic stenosis (PS) is the most common congenital cardiac disease in dogs. Boxers and English bulldogs are among the most commonly affected breeds and also commonly associated with an aberrant coronary artery (CA). If an aberrant CA is suspected and balloon valvuloplasty indicated, an intra-operative angiography is recommended prior to the procedure. ECG-gated computed tomography (CT) can be used to screen for CA anomalies in a quick and minimally-invasive way (preventing side effects associated with selective catheter angiography) and allowing early planning of the procedure. The aim of this case series was to report CT findings associated with PS diagnosed by echocardiography. Our database was retrospectively searched for cases of dogs with PS diagnosed by echocardiography, where an ECG-gated CT was performed. A total of six cases were retrieved: all were diagnosed with severe PS. Four dogs had concurrent congenital defects: two dogs had a patent ductus arteriosus, one dog had a ventricular septal defect and an overriding aorta, one dog had an aberrant CA. Detailed CT findings of all cases were reported, including one case of a patent ductus arteriosus and an overriding aorta not identified by transthoracic echocardiography. In addition, an abnormal single left coronary ostium, with a pre-pulmonic right CA was described. In conclusion, despite echocardiography remaining the gold standard for diagnosis and assessment of PS, ECG-gated-CT angiography is a complementary diagnostic method that may provide additional relevant information, shorten surgery/anaesthesia time and reduce the amount of radiation to which the clinician is subjected. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Coronary Computed Tomography Angiography vs Functional Stress Testing for Patients With Suspected Coronary Artery Disease: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Foy, Andrew J; Dhruva, Sanket S; Peterson, Brandon; Mandrola, John M; Morgan, Daniel J; Redberg, Rita F

    2017-11-01

    Coronary computed tomography angiography (CCTA) is a new approach for the diagnosis of anatomical coronary artery disease (CAD), but it is unclear how CCTA performs compared with the standard approach of functional stress testing. To compare the clinical effectiveness of CCTA with that of functional stress testing for patients with suspected CAD. A systematic literature search was conducted in PubMed and MEDLINE for English-language randomized clinical trials of CCTA published from January 1, 2000, to July 10, 2016. Researchers selected randomized clinical trials that compared a primary strategy of CCTA with that of functional stress testing for patients with suspected CAD and reported data on patient clinical events and changes in therapy. Two reviewers independently extracted data from and assessed the quality of the trials. This analysis followed the PRISMA statement for reporting systematic reviews and meta-analyses and used the Cochrane Collaboration's tool for assessing risk of bias in randomized trials. The Mantel-Haenszel method was used to conduct the primary analysis. Summary relative risks were calculated with a random-effects model. The outcomes of interest were all-cause mortality, cardiac hospitalization, myocardial infarction, invasive coronary angiography, coronary revascularization, new CAD diagnoses, and change in prescription for aspirin and statins. Thirteen trials were included, with 10 315 patients in the CCTA arm and 9777 patients in the functional stress testing arm who were followed up for a mean duration of 18 months. There were no statistically significant differences between CCTA and functional stress testing in death (1.0% vs 1.1%; risk ratio [RR], 0.93; 95% CI, 0.71-1.21) or cardiac hospitalization (2.7% vs 2.7%; RR, 0.98; 95% CI, 0.79-1.21), but CCTA was associated with a reduction in the incidence of myocardial infarction (0.7% vs 1.1%; RR, 0.71; 95% CI, 0.53-0.96). Patients undergoing CCTA were significantly more likely to undergo

  20. Angiography

    International Nuclear Information System (INIS)

    Grinnell, V.S.; Mehringer, C.M.; Hieshima, G.B.

    1987-01-01

    The history of angiography is short, with its centennial approaching. A very brief review of milestones begins with the discovery of x-rays in 1895. Only a few months later contrast agents too toxic for human use were being injected into cadavers, severed limbs, and animals. The next major developments came in the late 1970s when percutaneous translumbar aortography and cerebral angiography were described. Contrast agents were now less toxic, and clinically useful angiography was a reality. In 1953 a technique for percutaneous vascular catheterization which formed the basis of many catheterization techniques to follow was described. In the 1970s the development of less invasive diagnostic methods such as computed tomography and diagnostic ultrasound decreased the indications for angiography, but newer interventional techniques such as embolization therapy and angioplasty have taken up the slack. Angiography remains the most important way to demonstrate vascular diseases graphically. Specific techniques such as angioplasty and digital subtraction angiography will be dealt with in other chapters. The authors hope to provide an overview of major areas of angiographic utilization. The basic techniques of arterial puncture and catheterization have been well described elsewhere

  1. Prediction of Clinical Outcome After Acute Ischemic Stroke: The Value of Repeated Noncontrast Computed Tomography, Computed Tomographic Angiography, and Computed Tomographic Perfusion.

    Science.gov (United States)

    Dankbaar, Jan W; Horsch, Alexander D; van den Hoven, Andor F; Kappelle, L Jaap; van der Schaaf, Irene C; van Seeters, Tom; Velthuis, Birgitta K

    2017-09-01

    Early prediction of outcome in acute ischemic stroke is important for clinical management. This study aimed to compare the relationship between early follow-up multimodality computed tomographic (CT) imaging and clinical outcome at 90 days in a large multicenter stroke study. From the DUST study (Dutch Acute Stroke Study), patients were selected with (1) anterior circulation occlusion on CT angiography (CTA) and ischemic deficit on CT perfusion (CTP) on admission, and (2) day 3 follow-up noncontrast CT, CTP, and CTA. Follow-up infarct volume on noncontrast CT, poor recanalization on CTA, and poor reperfusion on CTP (mean transit time index ≤75%) were related to unfavorable outcome after 90 days defined as modified Rankin Scale 3 to 6. Four multivariable models were constructed: (1) only baseline variables (model 1), (2) model 1 with addition of infarct volume, (3) model 1 with addition of recanalization, and (4) model 1 with addition of reperfusion. Area under the curves of the receiver operating characteristic curves of the models were compared using the DeLong test. A total of 242 patients were included. Poor recanalization was found in 21%, poor reperfusion in 37%, and unfavorable outcome in 44%. The area under the curve of the receiver operating characteristic curve without follow-up imaging was 0.81, with follow-up noncontrast CT 0.85 ( P =0.02), CTA 0.86 ( P =0.01), and CTP 0.86 ( P =0.01). All 3 follow-up imaging modalities improved outcome prediction compared with no imaging. There was no difference between the imaging models. Follow-up imaging after 3 days improves outcome prediction compared with prediction based on baseline variables alone. CTA recanalization and CTP reperfusion do not outperform noncontrast CT at this time point. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00880113. © 2017 American Heart Association, Inc.

  2. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    Science.gov (United States)

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy.

    Science.gov (United States)

    Wichmann, Julian L; Gillott, Matthew R; De Cecco, Carlo N; Mangold, Stefanie; Varga-Szemes, Akos; Yamada, Ricardo; Otani, Katharina; Canstein, Christian; Fuller, Stephen R; Vogl, Thomas J; Todoran, Thomas M; Schoepf, U Joseph

    2016-02-01

    The aim of this study was to evaluate the impact of a noise-optimized virtual monochromatic imaging algorithm (VMI+) on image quality and diagnostic accuracy at dual-energy computed tomography angiography (CTA) of the lower extremity runoff. This retrospective Health Insurance Portability and Accountability Act-compliant study was approved by the local institutional review board. We evaluated dual-energy CTA studies of the lower extremity runoff in 48 patients (16 women; mean age, 63.3 ± 13.8 years) performed on a third-generation dual-source CT system. Images were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monochromatic (VMI) algorithms at 40 to 120 keV in 10-keV intervals. Vascular attenuation and image noise in 18 artery segments were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used to subjectively evaluate vascular attenuation and image noise. In a subgroup of 21 patients who underwent additional invasive catheter angiography, diagnostic accuracy for the detection of significant stenosis (≥50% lumen restriction) of F_0.5, 50-keV VMI+, and 60-keV VMI data sets were assessed. Objective image quality metrics were highest in the 40- and 50-keV VMI+ series (SNR: 20.2 ± 10.7 and 19.0 ± 9.5, respectively; CNR: 18.5 ± 10.3 and 16.8 ± 9.1, respectively) and were significantly (all P traditional VMI technique and standard linear blending for evaluation of the lower extremity runoff using dual-energy CTA.

  4. Diagnostic accuracy of second-generation dual-source computed tomography coronary angiography with iterative reconstructions: a real-world experience.

    Science.gov (United States)

    Maffei, E; Martini, C; Rossi, A; Mollet, N; Lario, C; Castiglione Morelli, M; Clemente, A; Gentile, G; Arcadi, T; Seitun, S; Catalano, O; Aldrovandi, A; Cademartiri, F

    2012-08-01

    The authors evaluated the diagnostic accuracy of second-generation dual-source (DSCT) computed tomography coronary angiography (CTCA) with iterative reconstructions for detecting obstructive coronary artery disease (CAD). Between June 2010 and February 2011, we enrolled 160 patients (85 men; mean age 61.2±11.6 years) with suspected CAD. All patients underwent CTCA and conventional coronary angiography (CCA). For the CTCA scan (Definition Flash, Siemens), we use prospective tube current modulation and 70-100 ml of iodinated contrast material (Iomeprol 400 mgI/ ml, Bracco). Data sets were reconstructed with iterative reconstruction algorithm (IRIS, Siemens). CTCA and CCA reports were used to evaluate accuracy using the threshold for significant stenosis at ≥50% and ≥70%, respectively. No patient was excluded from the analysis. Heart rate was 64.3±11.9 bpm and radiation dose was 7.2±2.1 mSv. Disease prevalence was 30% (48/160). Sensitivity, specificity and positive and negative predictive values of CTCA in detecting significant stenosis were 90.1%, 93.3%, 53.2% and 99.1% (per segment), 97.5%, 91.2%, 61.4% and 99.6% (per vessel) and 100%, 83%, 71.6% and 100% (per patient), respectively. Positive and negative likelihood ratios at the per-patient level were 5.89 and 0.0, respectively. CTCA with second-generation DSCT in the real clinical world shows a diagnostic performance comparable with previously reported validation studies. The excellent negative predictive value and likelihood ratio make CTCA a first-line noninvasive method for diagnosing obstructive CAD.

  5. SYNTAX score based on coronary computed tomography angiography may have a prognostic value in patients with complex coronary artery disease: An observational study from a retrospective cohort.

    Science.gov (United States)

    Suh, Young Joo; Han, Kyunghwa; Chang, Suyon; Kim, Jin Young; Im, Dong Jin; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Kim, Young Jin; Choi, Byoung Wook

    2017-09-01

    The SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery (SYNTAX) score is an invasive coronary angiography (ICA)-based score for quantifying the complexity of coronary artery disease (CAD). Although the SYNTAX score was originally developed based on ICA, recent publications have reported that coronary computed tomography angiography (CCTA) is a feasible modality for the estimation of the SYNTAX score.The aim of our study was to investigate the prognostic value of the SYNTAX score, based on CCTA for the prediction of major adverse cardiac and cerebrovascular events (MACCEs) in patients with complex CAD.The current study was approved by the institutional review board of our institution, and informed consent was waived for this retrospective cohort study. We included 251 patients (173 men, mean age 66.0 ± 9.29 years) who had complex CAD [3-vessel disease or left main (LM) disease] on CCTA. SYNTAX score was obtained on the basis of CCTA. Follow-up clinical outcome data regarding composite MACCEs were also obtained. Cox proportional hazards models were developed to predict the risk of MACCEs based on clinical variables, treatment, and computed tomography (CT)-SYNTAX scores.During the median follow-up period of 1517 days, there were 48 MACCEs. Univariate Cox hazards models demonstrated that MACCEs were associated with advanced age, low body mass index (BMI), and dyslipidemia (P < .2). In patients with LM disease, MACCEs were associated with a higher SYNTAX score. In patients with CT-SYNTAX score ≥23, patients who underwent coronary artery bypass graft surgery (CABG) and percutaneous coronary intervention had significantly lower hazard ratios than patients who were treated with medication alone. In multivariate Cox hazards model, advanced age, low BMI, and higher SYNTAX score showed an increased hazard ratio for MACCE, while treatment with CABG showed a lower hazard ratio (P < .2).On the basis of our results, CT-SYNTAX score

  6. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2015-11-15

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  7. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca

    2015-01-01

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  8. Optical Coherence Tomography Angiography in Retinal Diseases.

    Science.gov (United States)

    Chalam, K V; Sambhav, Kumar

    2016-01-01

    Optical coherence tomography angiography (OCTA) is a new, non-invasive imaging system that generates volumetric data of retinal and choroidal layers. It has the ability to show both structural and blood flow information. Split-spectrum amplitude-decorrelation angiography (SSADA) algorithm (a vital component of OCTA software) helps to decrease the signal to noise ratio of flow detection thus enhancing visualization of retinal vasculature using motion contrast. Published studies describe potential efficacy for OCTA in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age related macular degeneration (AMD), retinal vascular occlusions and sickle cell disease. OCTA provides a detailed view of the retinal vasculature, which allows accurate delineation of microvascular abnormalities in diabetic eyes and vascular occlusions. It helps quantify vascular compromise depending upon the severity of diabetic retinopathy. OCTA can also elucidate the presence of choroidal neovascularization (CNV) in wet AMD. In this paper, we review the knowledge, available in English language publications regarding OCTA, and compare it with the conventional angiographic standard, fluorescein angiography (FA). Finally, we summarize its potential applications to retinal vascular diseases. Its current limitations include a relatively small field of view, inability to show leakage, and tendency for image artifacts. Further larger studies will define OCTA's utility in clinical settings and establish if the technology may offer a non-invasive option of visualizing the retinal vasculature, enabling us to decrease morbidity through early detection and intervention in retinal diseases.

  9. Influence of heart rhythm, breathing and arm position during computed tomography scanning on the registration accuracy of electro anatomical map (EAM) images, left atrium three-dimensional computed tomography angiography images, and fluoroscopy time during ablation to treat atrial fibrillation

    International Nuclear Information System (INIS)

    Chono, Taiki; Shimoshige, Shinya; Yoshikawa, Kenta; Mizonobe, Kazuhusa; Ogura, Keishi

    2013-01-01

    In CARTOMERGE for treatment of atrial fibrillation (AF) by ablation, by integrating electro anatomical map (EAM) and left atrium three-dimensional computed tomography angiography (3D-CTA) images, identification of the ablation points is simplified and the procedure can be made carried out more rapidly. However, the influence that heart rhythm, breathing and arm position during CT scanning have on registration accuracy and fluoroscopy time is not clear. To clarify the influence on registration accuracy and fluoroscopy time of heart rhythm, breathing and arm position during CT scanning. The patients were CT-scanned during both sinus rhythm (SR) and AF in each study subject. We evaluated the registration accuracy of images reconstructed between the cardiac cycle and assessed the registration accuracy and fluoroscopy time of images obtained during inspiratory breath-hold, expiratory breath-hold and up and down position of the arm. Although the registration accuracy of the EAM image and left atrium 3D-CTA image showed a significant difference during SR, no significant difference was seen during AF. Expiratory breath-hold and down position of the arm resulted in the highest registration accuracy and the shortest fluoroscopy time. However, arm position had no significant effect on registration accuracy. Heart rhythm and breathing during CT scanning have a significant effect on the registration accuracy of EAM images, left atrium 3D-CTA images, and fluoroscopy time. (author)

  10. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  11. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M.; Hack, N.; Tiling, R. [Klinikum Grosshadern (Germany). Dept. of Nuclear Medicine; Jakobs, T.; Nikolaou, K.; Becker, C. [Klinikum Grosshadern (Germany). Dept. of Clinical Radiology; Ziegler, F. von; Knez, A. [Klinikum Grosshadern (Germany). Dept. of Cardiology; Koenig, A.; Klauss, V. [Medizinische Poliklinik-Innenstadt, Univ. of Munich (Germany). Dept. of Cardiology

    2007-07-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting ''obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 {+-} 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  12. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting.

    Science.gov (United States)

    Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J

    2018-01-01

    This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology

  13. Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Girinsky, Theodore, E-mail: girinsky.theodore@orange.fr [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); M’Kacher, Radhia [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Lessard, Nathalie [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Koscielny, Serge [Biostatistics and Epidemiology Unit, Institut Gustave Roussy, Villejuif (France); Elfassy, Eric; Raoux, François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France); Carde, Patrice [Department of Hematology, Institut Gustave Roussy, Villejuif (France); Santos, Marcos Dos [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Margainaud, Jean-Pierre [Department of Head and Neck Surgery, Institut Gustave Roussy, Villejuif (France); Sabatier, Laure [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Ghalibafian, Mithra [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Paul, Jean-François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France)

    2014-05-01

    Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

  14. Non-invasive diagnostic workup of patients with suspected stable angina by combined computed tomography coronary angiography and magnetic resonance perfusion imaging

    International Nuclear Information System (INIS)

    Kirschbaum, S.W.; Nieman, K.; Springeling, T.

    2011-01-01

    The background of this study was to evaluate additional adenosine magnetic resonance perfusion (MRP) imaging in the diagnostic workup of patients with suspected stable angina with computed tomography coronary angiography (CTCA) as first-line diagnostic modality. Two hundred and thirty symptomatic patients (male, 52%; age, 56 year) with suspected stable angina underwent CTCA. In patients with a stenosis of >50% as visually assessed, MRP was performed and the quantitative myocardial perfusion reserve index (MPRI) was calculated. Coronary flow reserve (CFR) using invasive coronary flow measurements served as the standard of reference. CTCA showed non-significant coronary artery disease (CAD) in 151/230 (66%) patients and significant CAD in 79/230 patients (34%), of whom 50 subsequently underwent MRP and CFR. MRP showed reduced perfusion in 32 patients (64%), which was confirmed by CFR in 27 (84%). All 18 cases of normal MRP (36%) were confirmed by CFR. The positive likelihood ratio of MRP for the presence of functional significant disease in patients with a lesion on CTCA was 4.49 (95% confidence interval [CI] 2.12-9.99). The negative likelihood ratio was 0.05 (95% CI 0.01-0.34). CTCA as first-line diagnostic modality excluded coronary artery disease in a high percentage of patients referred for diagnostic workup of suspected stable angina. MRP made a significant contribution to the detection of functional significant lesions in patients with a positive CTCA. (author)

  15. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Haga Teaching Hospital, The Hague (Netherlands); Sucha, Dominika; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Laufer, Ward; Chamuleau, Steven [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Herwerden, Lex.A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Symersky, Petr [Vrije Universiteit, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-06-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  16. Detection of hemodynamic impairment using magnetic resonance angiography in patients with internal carotid artery stenoocclusive disease. Comparison with quantitative brain perfusion single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Hirooka, Ryonoshin; Ogasawara, Kuniaki

    2008-01-01

    Cerebrovascular reactivity (CVR) to acetazolamideis a key parameter in determining the severity of hemodynamic impairment in patients with major cerebral artery occlusive disease. The aim of the present study is to validate the accuracy of magnetic resonance angiography (MRA) for detecting hemodynamic impairment by correlating detectability of the middle cerebral artery obtained by MRA with CVR measured by single-photon emission computed tomography (SPECT) in patients with internal carotid artery (ICA) occlusive disease. Ninety-four patients with chronic ICA occlusion underwent single slab three-dimensional time-of-flight MRA and SPECT. SPECT-CVR was calculated by measured cerebral blood flow before and after acetazolamide challenge. CVR was significantly lower in patients without detection of any portion (M1, M2 or M3) of the MCA than in those with detection of all portions. When SPECT-CVR lower than the mean- 2 standard deviation (SD) obtained in normal subjects was defined as reduced and the SPECT-CVR was assumed as the true determinant of hemodynamic impairment, MRA provided 92% sensitivity and 73% specificity, with 96% negative predictive value for detecting patients with reduced CVR. The present MRA method is effective for the identification of patients with hemodynamic impairment. (author)

  17. Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Kuettner, Axel; Lell, Michael M.; Wuest, Wolfgang; Scharf, Michael; Uder, Michael [University of Erlangen, Department of Radiology, Erlangen (Germany); Deak, Paul; Kalender, Willi A. [University of Erlangen, Department of Medical Physics, Erlangen (Germany); Keller, Andrea K.; Haeberle, Lothar [University of Erlangen, Department of Medical Informatics, Biometry and Epidemiology, Erlangen (Germany); Achenbach, Stephan; Seltmann, Martin [University of Erlangen, Department of Cardiology, Erlangen (Germany)

    2012-03-15

    To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. Estimates for mean relative ED was 7.1 {+-} 2.1 mSv/100 mAs for TCM and 12.5 {+-} 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR ({<=}60 bpm) was highest (49 {+-} 5%) compared to intermediate (60-70 bpm, 33 {+-} 12%) and high HR (>70 bpm, 29 {+-} 12%). However lowest ED is achieved at high HR (5.2 {+-} 1.5 mSv/100 mAs), compared with intermediate (6.7 {+-} 1.6 mSv/100 mAs) and low (8.3 {+-} 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. circle Monte Carlo simulations allow for individual radiation dose calculations. (orig.)

  18. Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch

    International Nuclear Information System (INIS)

    May, Matthias S.; Kuettner, Axel; Lell, Michael M.; Wuest, Wolfgang; Scharf, Michael; Uder, Michael; Deak, Paul; Kalender, Willi A.; Keller, Andrea K.; Haeberle, Lothar; Achenbach, Stephan; Seltmann, Martin

    2012-01-01

    To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. Estimates for mean relative ED was 7.1 ± 2.1 mSv/100 mAs for TCM and 12.5 ± 5.3 mSv/100 mAs for CTC (P 70 bpm, 29 ± 12%). However lowest ED is achieved at high HR (5.2 ± 1.5 mSv/100 mAs), compared with intermediate (6.7 ± 1.6 mSv/100 mAs) and low (8.3 ± 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. circle Monte Carlo simulations allow for individual radiation dose calculations. (orig.)

  19. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    International Nuclear Information System (INIS)

    Tanis, Wilco; Sucha, Dominika; Habets, Jesse; Laufer, Ward; Chamuleau, Steven; Herwerden, Lex.A. van; Symersky, Petr; Budde, Ricardo P.J.

    2015-01-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  20. Non-invasive imaging of myocardial bridge by coronary computed tomography angiography: the value of transluminal attenuation gradient to predict significant dynamic compression

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yuehua; Yu, Mengmeng; Zhang, Jiayin; Li, Minghua [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Institute of Diagnostic and Interventional Radiology, Shanghai (China); Lu, Zhigang; Wei, Meng [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Department of Cardiology, Shanghai (China)

    2017-05-15

    To study the diagnostic value of transluminal attenuation gradient (TAG) measured by coronary computed tomography angiography (CCTA) for identifying relevant dynamic compression of myocardial bridge (MB). Patients with confirmed MB who underwent both CCTA and ICA within one month were retrospectively included. TAG was defined as the linear regression coefficient between luminal attenuation and distance. The TAG of MB vessel, length and depth of MB were measured and correlated with the presence and degree of dynamic compression observed at ICA. Systolic compression ≥50 % was considered significant. 302 patients with confirmed MB lesions were included. TAG was lowest (-17.4 ± 6.7 HU/10 mm) in patients with significant dynamic compression and highest in patients without MB compression (-9.5 ± 4.3 HU/10 mm, p < 0.001). Linear correlation revealed relation between the percentage of systolic compression and TAG (Pearson correlation, r = -0.52, p < 0.001) and no significant relation between the percentage of systolic compression and MB depth or length. ROC curve analysis determined the best cut-off value of TAG as -14.8HU/10 mm (area under curve = 0.813, 95 % confidence interval = 0.764-0.855, p < 0.001), which yielded high diagnostic accuracy (82.1 %, 248/302). The degree of ICA-assessed systolic compression of MB significantly correlates with TAG but not MB depth or length. (orig.)

  1. Prognostic value of computed tomography coronary angiography in patients with suspected coronary artery disease: a 24-month follow-up study

    Energy Technology Data Exchange (ETDEWEB)

    Aldrovandi, Annachiara; Maffei, Erica; Seitun, Sara; Martini, Chiara; Ruffini, Livia; Crisi, Girolamo; Ardissino, Diego [Azienda Ospedaliero-Universitaria, Department of Radiology and Cardiology, Parma (Italy); Palumbo, Alessandro [Azienda Ospedaliero-Universitaria, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Brambilla, Valerio [University of Parma, Cardiovascular Prevention and Rehabilitation Unit, Don Gnocchi ONLUS, Parma (Italy); Zuccarelli, Alessandra [Ospedale di Carrara, Department of Cardiology, Carrara (Italy); Tarantini, Giuseppe [University of Padua, Department of Cardiology, Padua (Italy); Weustink, Annick C.; Mollet, Nico R.; Feyter, Pim J. de; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Cademartiri, Filippo [Azienda Ospedaliero-Universitaria, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Azienda Ospedaliero-Universitaria di Parma, Department of Radiology, c/o Piastra Tecnica - Piano 0 - CT Section, Parma (Italy)

    2009-07-15

    The aim of this study was to determine the predictive value of 64-slice computed tomography coronary angiography (CTCA) for major cardiac events in patients with suspected coronary artery disease (CAD). A total of 187 consecutive patients (119 men, age 62.5 {+-} 10.5 years) without known heart disease underwent single-source 64-slice CTCA (Somatom Sensation 64, Siemens) for clinical suspicion of CAD. Patients underwent follow-up for the occurrence of cardiac death, nonfatal myocardial infarction, unstable angina and cardiac revascularization. In total, 2,822 coronary segments were assessed. Forty-two segments (1.5%) were not assessable because of insufficient image quality. Overall, CTCA revealed absence of CAD in 65 (34.7%) patients, nonobstructive CAD (coronary plaque {<=}50%) in 87 (46.5%) patients and obstructive CAD (>50%) in 35 (18.8%) patients. A total of 20 major cardiac events (3 myocardial infarctions, 16 cardiac revascularizations, 1 unstable angina) occurred during a mean follow-up of 24 months. One noncardiac death occurred. Seventeen events occurred in the group of patients with obstructive CAD and three events occurred in the group of nonobstructive CAD. The event rate was 0% among patients with normal coronary arteries at CTCA. CTCA has a 100% negative predictive value for major cardiac events at 24-month follow-up in patients with normal coronary arteries. (orig.)

  2. Effect of diltiazem on myocardial infarct size estimated by enzyme release, serial thallium-201 single-photon emission computed tomography and radionuclide angiography

    International Nuclear Information System (INIS)

    Zannad, F.; Amor, M.; Karcher, G.; Maurin, P.; Ethevenot, G.; Sebag, C.; Bertrand, A.; Pernot, C.; Gilgenkrantz, J.M.

    1988-01-01

    Diltiazem is a calcium antagonist with demonstrated experimental cardioprotective effects. Its effects on myocardial infarct size were studied in 34 patients admitted within 6 hours after the first symptoms of acute myocardial infarction. These patients were randomized, double-blind to placebo or diltiazem (10-mg intravenous bolus followed by 15 mg/hr intravenous infusion during 72 hours, followed by 4 X 60 mg during 21 days). Myocardial infarct size was assessed by plasma creatine kinase and creatine kinase-MB indexes, perfusion defect scores using single-photon emission computed tomography with thallium-201 and left ventricular ejection fraction measured by radionuclide angiography. Tomographic and angiographic scanning was performed serially before randomization, after 48 hours and 21 days later. Groups were comparable in terms of age, sex, inclusion time and baseline infarct location and size. Results showed no difference in creatine kinase and creatine kinase-MB data between controls and treated patients, a significant decrease in the perfusion defect scores in the diltiazem group (+0.1 +/- 3.0 placebo vs -2.2 +/- 1.9 diltiazem, p less than 0.02) and a better ejection fraction recovery in the diltiazem group (-4.2 +/- 7.4 placebo vs +7.7 +/- 11.2 diltiazem, p less than 0.05). Myocardial infarct size estimates from perfusion defect scores and enzyme data were closely correlated. These preliminary results suggest that diltiazem may reduce ischemic injury in acute myocardial infarction

  3. Prognostic value of computed tomography coronary angiography in patients with suspected coronary artery disease: a 24-month follow-up study

    International Nuclear Information System (INIS)

    Aldrovandi, Annachiara; Maffei, Erica; Seitun, Sara; Martini, Chiara; Ruffini, Livia; Crisi, Girolamo; Ardissino, Diego; Palumbo, Alessandro; Brambilla, Valerio; Zuccarelli, Alessandra; Tarantini, Giuseppe; Weustink, Annick C.; Mollet, Nico R.; Feyter, Pim J. de; Krestin, Gabriel P.; Cademartiri, Filippo

    2009-01-01

    The aim of this study was to determine the predictive value of 64-slice computed tomography coronary angiography (CTCA) for major cardiac events in patients with suspected coronary artery disease (CAD). A total of 187 consecutive patients (119 men, age 62.5 ± 10.5 years) without known heart disease underwent single-source 64-slice CTCA (Somatom Sensation 64, Siemens) for clinical suspicion of CAD. Patients underwent follow-up for the occurrence of cardiac death, nonfatal myocardial infarction, unstable angina and cardiac revascularization. In total, 2,822 coronary segments were assessed. Forty-two segments (1.5%) were not assessable because of insufficient image quality. Overall, CTCA revealed absence of CAD in 65 (34.7%) patients, nonobstructive CAD (coronary plaque ≤50%) in 87 (46.5%) patients and obstructive CAD (>50%) in 35 (18.8%) patients. A total of 20 major cardiac events (3 myocardial infarctions, 16 cardiac revascularizations, 1 unstable angina) occurred during a mean follow-up of 24 months. One noncardiac death occurred. Seventeen events occurred in the group of patients with obstructive CAD and three events occurred in the group of nonobstructive CAD. The event rate was 0% among patients with normal coronary arteries at CTCA. CTCA has a 100% negative predictive value for major cardiac events at 24-month follow-up in patients with normal coronary arteries. (orig.)

  4. Contrast-enhanced computed tomography angiography and volume-rendered imaging for evaluation of cellophane banding in a dog with extrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    H. Yoon

    2011-04-01

    Full Text Available A 4-year-old, 1.8 kg, male, castrated Maltese was presented for evaluation of urolithiasis. Urinary calculi were composed of ammonium biurate. Preprandial and postprandial bile acids were 44.2 and 187.3 μmol/ , respectively (reference ranges 0–10 and 0–20 μmol/ , respectively. Single-phase contrast-enhanced computed tomography angiography (CTA with volume-rendered imaging (VRI was obtained. VRI revealed a portocaval shunt originating just cranial to a tributary of the gastroduodenal vein and draining into the caudal vena cava at the level of the epiploic foramen. CTA revealed a 3.66 mm-diameter shunt measured at the level of the termination of the shunt and a 3.79 mm-diameter portal vein measured at the level between the origin of the shunt and the porta of the liver. Surgery was performed using cellophane banding without attenuation. Follow-up single-phase CTA with VRI was obtained 10 weeks after surgery. VRI revealed no evidence of portosystemic communication on the level of a cellophane band and caudal to the cellophane band. CTA demonstrated an increased portal vein diameter (3.79–5.27 mm measured at the level between the origin of the shunt and the porta of the liver. Preprandial and postprandial bile acids were 25 and 12.5 μmol/ , respectively (aforementioned respective reference ranges, 3 months post-surgery. No problems were evident at 6 months.

  5. Computed tomography coronary angiography accuracy in women and men at low to intermediate risk of coronary artery disease

    International Nuclear Information System (INIS)

    Dharampal, Anoeshka S.; Papadopoulou, Stella L.; Rossi, Alexia; Weustink, Annick C.; Mollet, Nico R.A.; Meijboom, W. Bob; Neefjes, Lisan A.; Nieman, Koen; Feijter, Pim J. de; Boersma, Eric; Krestin, Gabriel P.

    2012-01-01

    To investigate the diagnostic accuracy of CT coronary angiography (CTCA) in women at low to intermediate pre-test probability of coronary artery disease (CAD) compared with men. In this retrospective study we included symptomatic patients with low to intermediate risk who underwent both invasive coronary angiography and CTCA. Exclusion criteria were previous revascularisation or myocardial infarction. The pre-test probability of CAD was estimated using the Duke risk score. Thresholds of less than 30 % and 30-90 % were used for determining low and intermediate risk, respectively. The diagnostic accuracy of CTCA in detecting obstructive CAD (≥50 % lumen diameter narrowing) was calculated on patient level. P < 0.05 was considered significant. A total of 570 patients (46 % women [262/570]) were included and stratified as low (women 73 % [80/109]) and intermediate risk (women 39 % [182/461]). Sensitivity, specificity, PPV and NPV were not significantly different in and between women and men at low and intermediate risk. For women vs. men at low risk they were 97 % vs. 100 %, 79 % vs. 90 %, 80 % vs. 80 % and 97 % vs. 100 %, respectively. For intermediate risk they were 99 % vs. 99 %, 72 % vs. 83 %, 88 % vs. 93 % and 98 % vs. 99 %, respectively. CTCA has similar diagnostic accuracy in women and men at low and intermediate risk. (orig.)

  6. Comparative analysis of the results of surgery for juvenile nasopharyngeal angiofibroma with the use of 3D reconstructions of computed tomography angiography

    Directory of Open Access Journals (Sweden)

    N. S. Grachev

    2017-01-01

    Full Text Available Rationale: The relapse rates after surgery for juvenile nasopharyngeal and/or skull base angiofibroma is in the range of 23 to 27.5%, which is mostly related to diagnostic issues. Aim: To perform a comparative analysis of the results of surgical treatment for juvenile nasopharyngeal and skull base angiofibroma based on our technique of 3D reconstructions of computed tomography angiograms in patients with primary tumors and with relapses. Materials and methods: We analyzed retrospectively the data from 32 patients with juvenile nasopharyngeal and skull base angiofibroma who had been diagnosed and treated from 2013 to 2017 (42 surgeries. Multislice computed tomography (MSCT angiography with 3D reconstruction was used for the planning of surgical approaches. At days 3 to 7 after the surgery, in 31 patients with stages II, IIIa and IIIb (according to U. Fisch classification modified by R. Andrews, 1989, we looked for residual tumor tissues by MSCT with standard analysis and with 3D MSCT angiography reconstructions, comparing them with their corresponding baseline images. The patients were divided into two groups: group 1, 17 patients with primary tumors (median age 13.5 years, group 2, 14 patients who had been previously operated (median age 14 years. Both groups were comparable in their clinical and demographic characteristics, as well as in the tumor staging (p > 0.05. Results: The relapse rates were 22.58% (7 / 31 patients, being 11.76% (2 / 17 in the group 1 and 35.71% (5 / 14 in the group 2 (p > 0.05. In each group, the maximal difference in the resected tumor volume was found in stage II patients, with more radical resection in the patients with primary tumors (p < 0.05. Contrast-enhanced MSCT showed residual tumor masses in 19 patients (8, with primary tumors and 11, with relapses. From those, 10 patients (3 with primary tumors and 7 who had underwent surgery earlier required second surgeries (4 patients were curatively operated, and 2

  7. Bone marrow edema pattern identification in patients with lytic bone lesions using digital subtraction angiography-like bone subtraction on large-area detector computed tomography.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Hossu, Gabriela; Lecocq, Sophie; Razeto, Marco; Louis, Matthias; Blum, Alain

    2014-03-01

    The objective of this study was to evaluate the performance of digital subtraction angiography (DSA)-like bone subtraction with 2 different registration methods for the identification of bone marrow edema pattern (BMEP) in patients with lytic bone lesions, using magnetic resonance imaging as the criterion standard. Fifty-five patients with a lytic bone lesion were included in this prospective study with approval from the ethics committee. All patients underwent magnetic resonance imaging and low-dose computed tomographic (CT) perfusion after signing an informed consent. Two CT volumes were used for bone subtraction, which was performed with 2 different algorithms (rigid and nonrigid). Enhancement at the nonlytic bone marrow was considered as a sign of BMEP. Two readers evaluated the images blindly. The presence of BMEP on bone-subtracted CT images was evaluated subjectively and quantitatively. Image quality was assessed. Magnetic resonance imaging was used as the criterion standard. Using a rigid registration method, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT with DSA-like bone subtraction BMEP was 77%, 100%, 100%, 68%, and 85%, respectively. The interobserver agreement was good (κ, 0.782). Image quality was better using a nonrigid registration. With this algorithm, artifacts interfered with image interpretation in only 5% of cases. However, there was a noticeable drop in sensitivity and negative predictive value when a nonrigid algorithm was used: 56% and 52%, respectively. The interobserver agreement was average with a nonrigid subtraction algorithm. Computed tomography with DSA-like bone subtraction is sensitive and highly specific for the identification of BMEP associated with lytic bone lesions. Rigid registering should be preferred, but nonrigid algorithms can be used as a second option when artifacts interfere with image interpretation.

  8. The prevalence and characteristics of intra-atrial right coronary artery anomaly in 9,284 patients referred for coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Opolski, Maksymilian P.; Pregowski, Jerzy; Kruk, Mariusz; Staruch, Adam D.; Witkowski, Adam; Demkow, Marcin; Hryniewiecki, Tomasz; Michalek, Piotr; Ruzyllo, Witold; Kepka, Cezary

    2014-01-01

    Objective: To determine the prevalence, radiologic patterns and clinical characteristics of intra-atrial right coronary artery (IARCA) among adult coronary computed tomography angiography (CCTA) population. Methods: We included 9,284 consecutive subjects who underwent CCTA at a single high-volume center. The presence of IARCA including the number, length and diameter of IARCA segments with accompanying atherosclerosis and coronary anomalies were evaluated. Additionally, clinical characteristics and midterm follow-up of IARCA patients were recorded. Results: The IARCA prevalence was 0.15% (14/9,284) with 15 intra-atrial segments. The intra-atrial segment length ranged from 14 to 53 mm, and the mean diameter proximal to the entry site was 3.3 ± 0.7 mm. IARCA was more often associated with intramuscular course of the left anterior descending coronary artery (29% vs. 4%, p = 0.001) and anomalous origin of the left circumflex artery from the right aortic sinus (14% vs. 0.3%, p = 0.001) compared with non-IARCA cases. The majority of IARCA patients were women (86%) presenting with supraventricular arrhythmia (71%). Compared with computed tomographic population without IARCA, IARCA subjects were younger (60 ± 12 vs. 54 ± 14 years, p = 0.037) and more often women (51% vs. 86%, p = 0.013). At a mean of 20 months follow-up of IARCA patients there were no adverse cardiac events except for supraventricular tachycardia episodes occurring in 36% of subjects. Conclusions: IARCA occurs rarely and is often associated with additional coronary anomalies. The clinical profile of IARCA patients is most often represented by middle-aged women with supraventricular arrhythmia showing favorable midterm prognosis

  9. Myocardial segmentation based on coronary anatomy using coronary computed tomography angiography: Development and validation in a pig model

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Mi Sun [Chung-Ang University College of Medicine, Department of Radiology, Chung-Ang University Hospital, Seoul (Korea, Republic of); Yang, Dong Hyun; Seo, Joon Beom; Kang, Joon-Won; Lim, Tae-Hwan [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Kim, Young-Hak; Kang, Soo-Jin; Jung, Joonho [Asan Medical Center, University of Ulsan College of Medicine, Heart Institute, Seoul (Korea, Republic of); Kim, Namkug [Asan Medical Center, University of Ulsan College of Medicine, Department of Convergence Medicine, Seoul (Korea, Republic of); Heo, Seung-Ho [Asan Medical Center, University of Ulsan College of Medicine, Asan institute for Life Science, Seoul (Korea, Republic of); Baek, Seunghee [Asan Medical Center, University of Ulsan College of Medicine, Department of Clinical Epidemiology and Biostatistics, Seoul (Korea, Republic of); Choi, Byoung Wook [Yonsei University, Department of Diagnostic Radiology, College of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    To validate a method for performing myocardial segmentation based on coronary anatomy using coronary CT angiography (CCTA). Coronary artery-based myocardial segmentation (CAMS) was developed for use with CCTA. To validate and compare this method with the conventional American Heart Association (AHA) classification, a single coronary occlusion model was prepared and validated using six pigs. The unstained occluded coronary territories of the specimens and corresponding arterial territories from CAMS and AHA segmentations were compared using slice-by-slice matching and 100 virtual myocardial columns. CAMS more precisely predicted ischaemic area than the AHA method, as indicated by 95% versus 76% (p < 0.001) of the percentage of matched columns (defined as percentage of matched columns of segmentation method divided by number of unstained columns in the specimen). According to the subgroup analyses, CAMS demonstrated a higher percentage of matched columns than the AHA method in the left anterior descending artery (100% vs. 77%; p < 0.001) and mid- (99% vs. 83%; p = 0.046) and apical-level territories of the left ventricle (90% vs. 52%; p = 0.011). CAMS is a feasible method for identifying the corresponding myocardial territories of the coronary arteries using CCTA. (orig.)

  10. Treatment Effect of Balloon Pulmonary Angioplasty in Chronic Thromboembolic Pulmonary Hypertension Quantified by Automatic Comparative Imaging in Computed Tomography Pulmonary Angiography.

    Science.gov (United States)

    Zhai, Zhiwei; Ota, Hideki; Staring, Marius; Stolk, Jan; Sugimura, Koichiro; Takase, Kei; Stoel, Berend C

    2018-05-01

    Balloon pulmonary angioplasty (BPA) in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) can have variable outcomes. To gain more insight into this variation, we designed a method for visualizing and quantifying changes in pulmonary perfusion by automatically comparing computed tomography (CT) pulmonary angiography before and after BPA treatment. We validated these quantifications of perfusion changes against hemodynamic changes measured with right-sided heart catheterization. We studied 14 consecutive CTEPH patients (12 women; age, 70.5 ± 24), who underwent CT pulmonary angiography and right-sided heart catheterization, before and after BPA. Posttreatment images were registered to pretreatment CT scans (using the Elastix toolbox) to obtain corresponding locations. Pulmonary vascular trees and their centerlines were detected using a graph cuts method and a distance transform method, respectively. Areas distal from vessels were defined as pulmonary parenchyma. Subsequently, the density changes within the vascular centerlines and parenchymal areas were calculated and corrected for inspiration level differences. For visualization, the densitometric changes were displayed in color-coded overlays. For quantification, the median and interquartile range of the density changes in the vascular and parenchymal areas (ΔVD and ΔPD) were calculated. The recorded changes in hemodynamic parameters, including changes in systolic, diastolic, and mean pulmonary artery pressure (ΔsPAP, ΔdPAP, and ΔmPAP, respectively) and vascular resistance (ΔPVR), were used as reference assessments of the treatment effect. Spearman correlation coefficients were employed to investigate the correlations between changes in perfusion and hemodynamic changes. Comparative imaging maps showed distinct patterns in perfusion changes among patients. Within pulmonary vessels, the interquartile range of ΔVD correlated significantly with ΔsPAP (R = -0.58, P = 0.03),

  11. Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography

    International Nuclear Information System (INIS)

    Yang, Lin; Liang, Changhong; Zhuang, Jian; Huang, Meiping; Liu, Hui

    2017-01-01

    Hybrid iterative reconstruction can reduce image noise and produce better image quality compared with filtered back-projection (FBP), but few reports describe optimization of the iteration level. We optimized the iteration level of iDose"4 and evaluated image quality for pediatric cardiac CT angiography. Children (n = 160) with congenital heart disease were enrolled and divided into full-dose (n = 84) and half-dose (n = 76) groups. Four series were reconstructed using FBP, and iDose"4 levels 2, 4 and 6; we evaluated subjective quality of the series using a 5-grade scale and compared the series using a Kruskal-Wallis H test. For FBP and iDose"4-optimal images, we compared contrast-to-noise ratios (CNR) and size-specific dose estimates (SSDE) using a Student's t-test. We also compared diagnostic-accuracy of each group using a Kruskal-Wallis H test. Mean scores for iDose"4 level 4 were the best in both dose groups (all P < 0.05). CNR was improved in both groups with iDose"4 level 4 as compared with FBP. Mean decrease in SSDE was 53% in the half-dose group. Diagnostic accuracy for the four datasets were in the range 92.6-96.2% (no statistical difference). iDose"4 level 4 was optimal for both the full- and half-dose groups. Protocols with iDose"4 level 4 allowed 53% reduction in SSDE without significantly affecting image quality and diagnostic accuracy. (orig.)

  12. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    Energy Technology Data Exchange (ETDEWEB)

    Felmly, Lloyd M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiothoracic Surgery, Department of Surgery, Charleston, SC (United States); De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-05-15

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m{sup 2} vs. 28.1±5.4 kg/m{sup 2}, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  13. Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Lin; Liang, Changhong [Southern Medical University, Guangzhou (China); Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China); Zhuang, Jian [Guangdong Academy of Medical Sciences, Dept. of Cardiac Surgery, Guangdong Cardiovascular Inst., Guangdong Provincial Key Lab. of South China Structural Heart Disease, Guangdong General Hospital, Guangzhou (China); Huang, Meiping [Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China); Guangdong Academy of Medical Sciences, Dept. of Catheterization Lab, Guangdong Cardiovascular Inst., Guangdong Provincial Key Lab. of South China Structural Heart Disease, Guangdong General Hospital, Guangzhou (China); Liu, Hui [Guangdong Academy of Medical Sciences, Dept. of Radiology, Guangdong General Hospital, Guangzhou (China)

    2017-01-15

    Hybrid iterative reconstruction can reduce image noise and produce better image quality compared with filtered back-projection (FBP), but few reports describe optimization of the iteration level. We optimized the iteration level of iDose{sup 4} and evaluated image quality for pediatric cardiac CT angiography. Children (n = 160) with congenital heart disease were enrolled and divided into full-dose (n = 84) and half-dose (n = 76) groups. Four series were reconstructed using FBP, and iDose{sup 4} levels 2, 4 and 6; we evaluated subjective quality of the series using a 5-grade scale and compared the series using a Kruskal-Wallis H test. For FBP and iDose{sup 4}-optimal images, we compared contrast-to-noise ratios (CNR) and size-specific dose estimates (SSDE) using a Student's t-test. We also compared diagnostic-accuracy of each group using a Kruskal-Wallis H test. Mean scores for iDose{sup 4} level 4 were the best in both dose groups (all P < 0.05). CNR was improved in both groups with iDose{sup 4} level 4 as compared with FBP. Mean decrease in SSDE was 53% in the half-dose group. Diagnostic accuracy for the four datasets were in the range 92.6-96.2% (no statistical difference). iDose{sup 4} level 4 was optimal for both the full- and half-dose groups. Protocols with iDose{sup 4} level 4 allowed 53% reduction in SSDE without significantly affecting image quality and diagnostic accuracy. (orig.)

  14. Clinical relevance and scope of accidental extracoronary findings in coronary computed tomography angiography: A cardiac versus thoracic FOV study

    International Nuclear Information System (INIS)

    Aglan, Iman; Jodocy, Daniel; Hiehs, Stefan; Soegner, Peter; Frank, Renate; Haberfellner, Berhard; Klauser, Andrea; Jaschke, Werner; Feuchtner, Gudrun M.

    2010-01-01

    Objective: To assess the spectrum and clinical relevance of extracoronary findings in coronary CT angiography (CCTA), and to compare a small (cardiac) field of view (FOV) to a large (thoracic) FOV setting. Material and methods: 1084 consecutive patients (mean 57 years) with low-to-intermediate risk of coronary artery disease were enrolled. 542 CCTA scans were interpreted with small FOV (160-190 mm 2 ) encompassing the cardiac region. In another 542 CCTA (patients matched for age and gender), read-out of an additional full FOV (>320 mm 2 ) covering the thorax was performed. Clinical relevance of extracoronary findings was considered as either 'significant' or 'non-significant'. 'Significant' findings were subclassified as either score 1: findings necessitating immediate therapeutic actions, or score 2: findings with undoubted clinical or prognostic relevance, requiring clinical awareness, follow-up or further investigations (non-urgent). 'Non-significant' findings were assigned to either score 3: findings not requiring follow-up or further tests, or as score 4: irrelevant incidental findings. Results: Significantly more patients with extracoronary findings were identified by using a full FOV with 43.2% (234/542) compared to a small FOV with 33.6% (182/542) (p = 0.001). Similarly, a higher total number of extracoronary findings (n = 394) was found on full FOV compared to small FOV (n = 250) (p 2 aortic valve orifice area. Conclusions: The interpretation of extracoronary findings on CCTA scans is mandatory given high prevalence of clinically significant findings by using a full 'thoracic' FOV.

  15. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    International Nuclear Information System (INIS)

    Felmly, Lloyd M.; De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D.; Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R.; Mangold, Stefanie; Vogl, Thomas J.; Wichmann, Julian L.

    2017-01-01

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m 2 vs. 28.1±5.4 kg/m 2 , P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  16. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lee, Jung S.; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Choo, Ki S.; Lee, Jun S.

    2007-01-01

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  17. Clinical relevance and scope of accidental extracoronary findings in coronary computed tomography angiography: A cardiac versus thoracic FOV study

    Energy Technology Data Exchange (ETDEWEB)

    Aglan, Iman; Jodocy, Daniel; Hiehs, Stefan; Soegner, Peter; Frank, Renate; Haberfellner, Berhard; Klauser, Andrea; Jaschke, Werner [Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria); Feuchtner, Gudrun M. [Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria)], E-mail: Gudrun.Feuchtner@i-med.ac.at

    2010-04-15

    Objective: To assess the spectrum and clinical relevance of extracoronary findings in coronary CT angiography (CCTA), and to compare a small (cardiac) field of view (FOV) to a large (thoracic) FOV setting. Material and methods: 1084 consecutive patients (mean 57 years) with low-to-intermediate risk of coronary artery disease were enrolled. 542 CCTA scans were interpreted with small FOV (160-190 mm{sup 2}) encompassing the cardiac region. In another 542 CCTA (patients matched for age and gender), read-out of an additional full FOV (>320 mm{sup 2}) covering the thorax was performed. Clinical relevance of extracoronary findings was considered as either 'significant' or 'non-significant'. 'Significant' findings were subclassified as either score 1: findings necessitating immediate therapeutic actions, or score 2: findings with undoubted clinical or prognostic relevance, requiring clinical awareness, follow-up or further investigations (non-urgent). 'Non-significant' findings were assigned to either score 3: findings not requiring follow-up or further tests, or as score 4: irrelevant incidental findings. Results: Significantly more patients with extracoronary findings were identified by using a full FOV with 43.2% (234/542) compared to a small FOV with 33.6% (182/542) (p = 0.001). Similarly, a higher total number of extracoronary findings (n = 394) was found on full FOV compared to small FOV (n = 250) (p < 0.001). The detection rate of clinically significant findings was higher by using full FOV compared to small FOV (25.6% versus 15.4%) (p < 0.001), out of those 2.2% versus 1.8% of findings required immediate actions (score 1), and 23.4% versus 13.6% (p = 0.0001), respectively were of clinical relevance (non-urgent, score 2). The rate of malign findings was 0.2%, and of acute pulmonary embolism 0.1%. More lung pathologies were observed by using full FOV compared to small FOV (22% versus 7%) (p < 0.0001), and the detection rate of

  18. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    International Nuclear Information System (INIS)

    Ferencik, Maros; Lisauskas, Jennifer B.; Cury, Ricardo C.; Hoffmann, Udo; Abbara, Suhny; Achenbach, Stephan; Karl, W. Clem; Brady, Thomas J.; Chan, Raymond C.

    2006-01-01

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 ± 5 years, mean heart rate 54 ± 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 ± 3.8 mm 2 and -0.2 ± 2.2 mm 2 (p 2 , respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area

  19. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Shapiro, Michael D.; Pena, Antonio J.; Nichols, John H.; Worrell, Stewart; Bamberg, Fabian; Dannemann, Nina; Abbara, Suhny; Cury, Ricardo C.; Brady, Thomas J.; Hoffmann, Udo

    2008-01-01

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 ± 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 ± 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration

  20. Quantitative perfusion computed tomography measurements of cerebral hemodynamics: Correlation with digital subtraction angiography identified primary and secondary cerebral collaterals in internal carotid artery occlusive disease

    International Nuclear Information System (INIS)

    Cheng Xiaoqing; Tian Jianming; Zuo Changjing; Liu Jia; Zhang Qi; Lu Guangming

    2012-01-01

    Background: The aim of the present study was to assess hemodynamic variations in symptomatic unilateral internal carotid artery occlusion (ICAO) patients with primary collateral flow via circle of Willis or secondary collateral flow via ophthalmic artery and/or leptomeningeal collaterals. Methods: Thirty-eight patients with a symptomatic unilateral ICAO were enrolled in the study. Based on digital subtraction angiography (DSA) findings, patients were classified into 2 groups: primary collateral (n = 14) and secondary collateral (n = 24) groups. Collateral flow hemodynamics were investigated with perfusion computed tomography (PCT) by measuring the cerebral blood flow (CBF), cerebral blood volume (CBV) and time to peak (TTP) in the hemispheres ipsilateral and contralateral to ICAO. Based on the measurements, the ipsilateral to contralateral ratio for each parameter was calculated and compared. Results: Irrespective of the collateral patterns, ipsilateral CBF was not significantly different from that of the contralateral hemisphere (P = 0.285); ipsilateral CBV and TTP was significantly increased compared with those of the contralateral hemisphere (P = 0.000 and P = 0.000 for CBV and TTP, respectively). Furthermore, patients with secondary collaterals had significantly larger ipsilateral-to-contralateral ratios for both CBV (rCBV, P = 0.0197) and TTP (rTTP, P = 0.000) than those of patients with only primary collaterals. These two groups showed no difference in ipsilateral-to-contralateral ratio for CBF (rCBF, P = 0.312). Conclusion: Patients with symptomatic unilateral ICAO in our study were in an autoregulatory vasodilatation status. Moreover, secondary collaterals in ICAO patients were correlated with ipsilateral CBV and delayed TTP that suggested severe hemodynamic impairment, presumably increasing the risk of ischemic events.

  1. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Michael D. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Pena, Antonio J.; Nichols, John H. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Worrell, Stewart [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Bamberg, Fabian [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Dannemann, Nina [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Abbara, Suhny; Cury, Ricardo C.; Brady, Thomas J. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Hoffmann, Udo [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States)], E-mail: uhoffmann@partners.org

    2008-04-15

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 {+-} 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 {+-} 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration.

  2. Diagnostic performance of coronary computed tomography angiography versus exercise electrocardiography for coronary artery disease: a systematic review and meta-analysis.

    Science.gov (United States)

    Yin, Xinxin; Wang, Jiali; Zheng, Wen; Ma, Jingjing; Hao, Panpan; Chen, Yuguo

    2016-07-01

    Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95-0.99] and 0.66 (95% CIs: 0.59-0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81-0.87) and 0.75 (95% CIs: 0.71-0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07-346.55) and 6.28 (95% CIs: 2.06-19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks' test showed no potential publication bias (P=0.17). CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD.

  3. Prognostic value of computed tomography pulmonary angiography indices in patients with cancer-related pulmonary embolism: Data from a multicenter cohort study

    International Nuclear Information System (INIS)

    Plasencia-Martínez, Juana María; Carmona-Bayonas, Alberto; Calvo-Temprano, David; Jiménez-Fonseca, Paula; Fenoy, Francisco; Benegas, Mariana; Sánchez, Marcelo; Font, Carme; Varona, Diego; Martínez de la Haza, David

    2017-01-01

    Highlights: • CTPA can predict the prognosis of pulmonary embolism in cancer patients. • Right ventricular dysfunction (RVD) is predictive of complications at 15 days. • The Frank-Starling mechanism is the theoretical framework to interpret RVD signs. • Pulmonary artery obstruction plays a pathophysiological role only in subjects with RVD. • A proposal for an explanation of clinical-radiological dissociation is presented. - Abstract: Objective: To analyze the prognostic value of pulmonary artery obstruction versus right-ventricle (RV) dysfunction radiologic indices in cancer-related pulmonary embolism (PE). Methods: We enrolled 303 consecutive patients with paraneoplastic PE, evaluated by computed tomography pulmonary angiography (CTPA) between 2013 and 2014. The primary outcome measure was serious complications at 15 days. Multivariate analyses were conducted by using binary logistic and robust regressions. Radiological features such as the Qanadli index (QI) and RV dysfunction signs were analyzed with Spearman’s partial rank correlations. Results: RV diameter was the only radiological variable associated with an adverse outcome. Subjects with enlarged RV (diameter > 45 mm) had more 15-day complications (58% versus 40%, p = 0.001). The QI correlated with the RV diameter (r = 0.28, p < 0.001), left ventricle diameter (r = −0.19, p < 0.001), right ventricular-to-left ventricular diameter ratio (r = 0.39, p < 0.001), pulmonary artery diameter (r = 0.22, p < 0.001), and pulmonary artery/ascending aorta ratio (r = 0.27, p < 0.001). A QI ≥ 50% was only associated with 15-day complications in subjects with enlarged RV, inverted intraventricular septum, or chronic cardiopulmonary diseases. The central or peripheral PE location did not affect the correlations among radiological variables and was not associated with clinical outcomes. Conclusions: Right ventricular dysfunction signs in CTPA are more useful than QI in predicting cancer-related PE outcome.

  4. Quantitative coronary plaque analysis predicts high-risk plaque morphology on coronary computed tomography angiography: results from the ROMICAT II trial.

    Science.gov (United States)

    Liu, Ting; Maurovich-Horvat, Pál; Mayrhofer, Thomas; Puchner, Stefan B; Lu, Michael T; Ghemigian, Khristine; Kitslaar, Pieter H; Broersen, Alexander; Pursnani, Amit; Hoffmann, Udo; Ferencik, Maros

    2018-02-01

    Semi-automated software can provide quantitative assessment of atherosclerotic plaques on coronary CT angiography (CTA). The relationship between established qualitative high-risk plaque features and quantitative plaque measurements has not been studied. We analyzed the association between quantitative plaque measurements and qualitative high-risk plaque features on coronary CTA. We included 260 patients with plaque who underwent coronary CTA in the Rule Out Myocardial Infarction/Ischemia Using Computer Assisted Tomography (ROMICAT) II trial. Quantitative plaque assessment and qualitative plaque characterization were performed on a per coronary segment basis. Quantitative coronary plaque measurements included plaque volume, plaque burden, remodeling index, and diameter stenosis. In qualitative analysis, high-risk plaque was present if positive remodeling, low CT attenuation plaque, napkin-ring sign or spotty calcium were detected. Univariable and multivariable logistic regression analyses were performed to assess the association between quantitative and qualitative high-risk plaque assessment. Among 888 segments with coronary plaque, high-risk plaque was present in 391 (44.0%) segments by qualitative analysis. In quantitative analysis, segments with high-risk plaque had higher total plaque volume, low CT attenuation plaque volume, plaque burden and remodeling index. Quantitatively assessed low CT attenuation plaque volume (odds ratio 1.12 per 1 mm 3 , 95% CI 1.04-1.21), positive remodeling (odds ratio 1.25 per 0.1, 95% CI 1.10-1.41) and plaque burden (odds ratio 1.53 per 0.1, 95% CI 1.08-2.16) were associated with high-risk plaque. Quantitative coronary plaque characteristics (low CT attenuation plaque volume, positive remodeling and plaque burden) measured by semi-automated software correlated with qualitative assessment of high-risk plaque features.

  5. Evaluation of right ventricular function by coronary computed tomography angiography using a novel automated 3D right ventricle volume segmentation approach: a validation study.

    Science.gov (United States)

    Burghard, Philipp; Plank, Fabian; Beyer, Christoph; Müller, Silvana; Dörler, Jakob; Zaruba, Marc-Michael; Pölzl, Leo; Pölzl, Gerhard; Klauser, Andrea; Rauch, Stefan; Barbieri, Fabian; Langer, Christian-Ekkehardt; Schgoer, Wilfried; Williamson, Eric E; Feuchtner, Gudrun

    2018-06-04

    To evaluate right ventricle (RV) function by coronary computed tomography angiography (CTA) using a novel automated three-dimensional (3D) RV volume segmentation tool in comparison with clinical reference modalities. Twenty-six patients with severe end-stage heart failure [left ventricle (LV) ejection fraction (EF) right heart invasive catheterisation (IC). Automated 3D RV volume segmentation was successful in 26 (100%) patients. Read-out time was 3 min 33 s (range, 1 min 50s-4 min 33s). RV EF by CTA was stronger correlated with right atrial pressure (RAP) by IC (r = -0.595; p = 0.006) but weaker with TAPSE (r = 0.366, p = 0.94). When comparing TAPSE with RAP by IC (r = -0.317, p = 0.231), a weak-to-moderate non-significant inverse correlation was found. Interobserver correlation was high with r = 0.96 (p right atrium (RA) and right ventricle (RV) was 196.9 ± 75.3 and 217.5 ± 76.1 HU, respectively. Measurement of RV function by CTA using a novel 3D volumetric segmentation tool is fast and reliable by applying a dedicated biphasic injection protocol. The RV EF from CTA is a closer surrogate of RAP than TAPSE by TTE. • Evaluation of RV function by cardiac CTA by using a novel 3D volume segmentation tool is fast and reliable. • A biphasic contrast agent injection protocol ensures homogenous RV contrast attenuation. • Cardiac CT is a valuable alternative modality to CMR for the evaluation of RV function.

  6. {sup 18}F-fluorodeoxyglucose positron emission tomography combined with whole-body computed tomographic angiography in critically ill patients with suspected severe sepsis with no definite diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Mandry, Damien [CHU Nancy, Pole d' imagerie, Nancy (France); University of Lorraine, Faculty of Medicine, Nancy (France); INSERM, UMR 947, Nancy (France); Tatopoulos, Alexis; Lemarie, Jeremie; Bollaert, Pierre-Edouard; Gibot, Sebastien [University of Lorraine, Faculty of Medicine, Nancy (France); CHU de Nancy - Hopital Central, Service de Reanimation Medicale, Nancy (France); INSERM, UMR 1116, Nancy (France); Chevalier-Mathias, Elodie [CHU Nancy, Pole d' imagerie, Nancy (France); INSERM, UMR 947, Nancy (France); Nancyclotep, Experimental Imaging Platform, Nancy (France); Roch, Veronique [CHU Nancy, Pole d' imagerie, Nancy (France); Nancyclotep, Experimental Imaging Platform, Nancy (France); Olivier, Pierre [CHU Nancy, Pole d' imagerie, Nancy (France); University of Lorraine, Faculty of Medicine, Nancy (France); Nancyclotep, Experimental Imaging Platform, Nancy (France); Marie, Pierre-Yves [CHU Nancy, Pole d' imagerie, Nancy (France); University of Lorraine, Faculty of Medicine, Nancy (France); INSERM, UMR 1116, Nancy (France); Nancyclotep, Experimental Imaging Platform, Nancy (France)

    2014-10-15

    Timely identification of septic foci is critical in patients with severe sepsis or septic shock of unknown origin. This prospective pilot study aimed to assess {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET), combined with whole-body computed tomographic angiography (CTA), in patients with suspected severe sepsis and for whom the prior diagnostic workup had been inconclusive. Patients hospitalized in an intensive care unit with a suspected severe sepsis but no definite diagnosis after 48 h of extensive investigations were prospectively included and referred for a whole body FDG-PET/CTA. Results from FDG-PET/CTA were assessed according to the final diagnosis obtained after follow-up and additional diagnostic workup. Seventeen patients were prospectively included, all on mechanical ventilation and 14 under vasopressor drugs. The FDG-PET/CTA exam 1) was responsible for only one desaturation and one hypotension, both quickly reversible under treatment; 2) led to suspect 16 infectious sites among which 13 (81 %) could be confirmed by further diagnostic procedures; and 3) triggered beneficial changes in the medical management of 12 of the 17 study patients (71 %). The FDG-PET/CTA images showed a single or predominant infectious focus in two cases where CTA was negative and in three cases where CTA exhibited multiple possible foci. Whole-body FDG-PET/CTA appears to be feasible, relatively safe, and provides reliable and useful information, when prospectively planned in patients with suspected severe sepsis and for whom prior diagnostic workup had been inconclusive. The FDG-PET images are particularly helpful when CTA exhibits no or multiple possible sites. (orig.)

  7. Sensitivity of 3D gradient recalled echo susceptibility-weighted imaging technique compared to computed tomography angiography for detection of middle cerebral artery thrombus in acute stroke

    Directory of Open Access Journals (Sweden)

    Amit Agarwal

    2014-11-01

    Full Text Available We aimed at comparing the sensitivity of magnetic resonance (MR susceptibility-weighted imaging (SWI with computed tomography angiography (CTA in the detection of middle cerebral artery (MCA thrombus in acute stroke. Seventy-nine patients with acute MCA stroke was selected using our search engine software; only the ones showing restricted diffusion in the MCA territory on diffusion-weighted images were included. We finally selected 35 patients who had done both MRI (including SWI and CTA. Twenty random subjects with completely normal MRI (including SWI exam were selected as control. Two neuroradiologists (blinded to the presence or absence of stroke reviewed the SW images and then compared the findings with CT angiogram (in patients with stroke. The number of MCA segments showing thrombus in each patient was tabulated to estimate the thrombus burden. Thrombus was detected on SWI in one or more MCA segments in 30 out of 35 patients, on the first review. Of the 30, SWI showed thrombus in more than one MCA segments in 7 patients. CTA depicted branch occlusion in 31 cases. Thrombus was seen on both SWI and CTA in 28 patients. Thrombus was noted in two patients on SWI only, with no corresponding abnormality seen on CTA. Two patients with acute MCA showed no vascular occlusion or thrombus on either CTA or SWI. Only two case of false-positive thrombus was reported in normal control subjects. Susceptibility-weighted images had sensitivity and specificity of 86% and 90% respectively, with positive predictive value 94%. Sensitivity was 86% for SWI, compared with 89% for CTA, and this difference was statistically insignificant (P>0.05. Of all the positive cases on CTA (31 corresponding thrombus was seen on SWI in 90% of subjects (28 of 31. Susceptibility-weighted imaging has high sensitivity for detection of thrombus in acute MCA stroke. Moreover, SWI is a powerful technique for estimation of thrombus burden, which can be challenging on CTA.

  8. Prognostic value of computed tomography pulmonary angiography indices in patients with cancer-related pulmonary embolism: Data from a multicenter cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Plasencia-Martínez, Juana María, E-mail: plasen79@gmail.com [Radiology Department, Hospital Universitario Morales Meseguer, Av Marqués de los Vélez, s/n, 30008, Murcia (Spain); Carmona-Bayonas, Alberto [Hematology and Medical Oncology Department, Hospital Universitario Morales Meseguer, Av Marqués de los Vélez, s/n, 30008, Murcia (Spain); Calvo-Temprano, David [Radiology Department, Hospital Universitario Central de Asturias, Avenida de Roma, s/n, 33011, Oviedo (Spain); Jiménez-Fonseca, Paula [Medical Oncology Department, Hospital Universitario Central de Asturias, Avenida de Roma, s/n, 33011, Oviedo (Spain); Fenoy, Francisco [Department of Physiology, Faculty of Medicine, Campus Universitario de Espinardo, University of Murcia, s/n, 30100 Espinardo, Murcia (Spain); Benegas, Mariana; Sánchez, Marcelo [Radiology Department, Hospital Clínic de Barcelona (HCB), Villarroel, 170, 08036, Barcelona (Spain); Font, Carme [Medical Oncology Department, Hospital Clínic de Barcelona, Translational Genomics and Targeted Therapeutics in Solid Tumors, IDIBAPS, Villarroel, 170, 08036, Barcelona (Spain); Varona, Diego [Radiology Department, Hospital Universitari Vall d’Hebron, Passeig de la Vall d' Hebron, 119-129, 08035, Barcelona (Spain); Martínez de la Haza, David [Radiology Department, Hospital Duran i Reynals, Institut Català d’Oncologia (ICO), Avinguda Granvia, 199-203, 08907, Hospitalet de Llobregat, Barcelona (Spain); and others

    2017-02-15

    Highlights: • CTPA can predict the prognosis of pulmonary embolism in cancer patients. • Right ventricular dysfunction (RVD) is predictive of complications at 15 days. • The Frank-Starling mechanism is the theoretical framework to interpret RVD signs. • Pulmonary artery obstruction plays a pathophysiological role only in subjects with RVD. • A proposal for an explanation of clinical-radiological dissociation is presented. - Abstract: Objective: To analyze the prognostic value of pulmonary artery obstruction versus right-ventricle (RV) dysfunction radiologic indices in cancer-related pulmonary embolism (PE). Methods: We enrolled 303 consecutive patients with paraneoplastic PE, evaluated by computed tomography pulmonary angiography (CTPA) between 2013 and 2014. The primary outcome measure was serious complications at 15 days. Multivariate analyses were conducted by using binary logistic and robust regressions. Radiological features such as the Qanadli index (QI) and RV dysfunction signs were analyzed with Spearman’s partial rank correlations. Results: RV diameter was the only radiological variable associated with an adverse outcome. Subjects with enlarged RV (diameter > 45 mm) had more 15-day complications (58% versus 40%, p = 0.001). The QI correlated with the RV diameter (r = 0.28, p < 0.001), left ventricle diameter (r = −0.19, p < 0.001), right ventricular-to-left ventricular diameter ratio (r = 0.39, p < 0.001), pulmonary artery diameter (r = 0.22, p < 0.001), and pulmonary artery/ascending aorta ratio (r = 0.27, p < 0.001). A QI ≥ 50% was only associated with 15-day complications in subjects with enlarged RV, inverted intraventricular septum, or chronic cardiopulmonary diseases. The central or peripheral PE location did not affect the correlations among radiological variables and was not associated with clinical outcomes. Conclusions: Right ventricular dysfunction signs in CTPA are more useful than QI in predicting cancer-related PE outcome.

  9. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    Science.gov (United States)

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

    Science.gov (United States)

    Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C

    2013-06-01

    Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.

  11. Incremental value of B-type natriuretic peptide for detection and risk reclassification of obstructive coronary artery disease on computed tomography angiography.

    Science.gov (United States)

    Kawabe, Masayuki; Sato, Akira; Hoshi, Tomoya; Endo, Masae; Yoshida, Ikuo; Aonuma, Kazutaka

    2017-04-01

    B-type natriuretic peptide (BNP) is well known to increase as a result of left ventricular systolic dysfunction and is a useful diagnostic marker for heart failure. The purpose of this study was to assess the incremental value of BNP for predicting obstructive coronary artery disease (CAD) on computed tomography angiography (CTA) in patients with suspected CAD. This was an observational analysis of patients with stable CAD undergoing CTA in our institution between April 2008 and June 2014. Consecutive 947 patients with suspected CAD who underwent 64-slice CTA were enrolled. Obstructive CAD was defined as more than 50% luminal narrowing. We divided the patients into 2 groups according to median BNP value (20.3pg/ml). Duke clinical score for obstructive CAD was calculated for each patient. Obstructive CAD was found in 273 (28.0%) patients. Median follow-up period was 37 months (interquartile range 21-55 months). Kaplan-Meier curves showed that BNP above median was significantly associated with major adverse cardiac events (p=0.001). In multivariable logistic analysis, patients with BNP above median were associated with the presence of obstructive CAD, as compared with BNP below median [odds ratio, 2.55; 95% confidence interval (CI), 1.79-3.63; pvalue of the Duke clinical score and BNP, the predictive value of the Duke clinical score [area under the curve (AUC), 0.714] could be increased by BNP (AUC 0.745 for the combined model; prisk score. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  12. A Novel Pairwise Comparison-Based Method to Determine Radiation Dose Reduction Potentials of Iterative Reconstruction Algorithms, Exemplified Through Circle of Willis Computed Tomography Angiography.

    Science.gov (United States)

    Ellmann, Stephan; Kammerer, Ferdinand; Brand, Michael; Allmendinger, Thomas; May, Matthias S; Uder, Michael; Lell, Michael M; Kramer, Manuel

    2016-05-01

    The aim of this study was to determine the dose reduction potential of iterative reconstruction (IR) algorithms in computed tomography angiography (CTA) of the circle of Willis using a novel method of evaluating the quality of radiation dose-reduced images. This study relied on ReconCT, a proprietary reconstruction software that allows simulating CT scans acquired with reduced radiation dose based on the raw data of true scans. To evaluate the performance of ReconCT in this regard, a phantom study was performed to compare the image noise of true and simulated scans within simulated vessels of a head phantom. That followed, 10 patients scheduled for CTA of the circle of Willis were scanned according to our institute's standard protocol (100 kV, 145 reference mAs). Subsequently, CTA images of these patients were reconstructed as either a full-dose weighted filtered back projection or with radiation dose reductions down to 10% of the full-dose level and Sinogram-Affirmed Iterative Reconstruction (SAFIRE) with either strength 3 or 5. Images were marked with arrows pointing on vessels of different sizes, and image pairs were presented to observers. Five readers assessed image quality with 2-alternative forced choice comparisons. In the phantom study, no significant differences were observed between the noise levels of simulated and true scans in filtered back projection, SAFIRE 3, and SAFIRE 5 reconstructions.The dose reduction potential for patient scans showed a strong dependence on IR strength as well as on the size of the vessel of interest. Thus, the potential radiation dose reductions ranged from 84.4% for the evaluation of great vessels reconstructed with SAFIRE 5 to 40.9% for the evaluation of small vessels reconstructed with SAFIRE 3. This study provides a novel image quality evaluation method based on 2-alternative forced choice comparisons. In CTA of the circle of Willis, higher IR strengths and greater vessel sizes allowed higher degrees of radiation dose

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  14. Angiographic patterns of in-stent restenosis classified by computed tomography in patients with drug-eluting stents: correlation with invasive coronary angiography

    International Nuclear Information System (INIS)

    Pan, Jingwei; Lu, Zhigang; Wei, Meng; Zhang, Jiayin; Li, Minghua

    2013-01-01

    To evaluate the diagnostic accuracy of Mehran's in-stent restenosis (ISR) classification by coronary computed angiography (CCTA), with reference to invasive coronary angiography (ICA). Consecutive symptomatic patients, who had clinically suspected ISR and implanted stent diameter ≥ 3 mm, were prospectively enrolled in our study. Mehran's classification was employed by CCTA and ICA to classify ISR lesions into four subtypes: focal, diffuse intrastent, diffuse proliferative and total occlusion. CCTA and ICA measurement of lesion length was further compared. Sixty-one patients with 101 implanted stents were included in our study. The overall sensitivity, specificity, PPV and NPV of CCTA diagnosis of binary ISR, as shown by patient-based analysis (n = 61), were 100 % (49/49), 75 % (8/12), 92.45 % (49/53) and 100 % (8/8) respectively. Mehran's classification of CCTA correlated well with ICA findings. The diagnostic accuracy of CCTA for class I, class II, class III and class IV lesions was 92.5 %, 91.67 %, 100 % and 100 % respectively. Lesion length was assessed to be significantly longer with CCTA than with ICA (11.03 ± 5.89 mm versus 8.56 ± 4.99 mm, P < 0.001). Angiographic patterns of in-stent restenosis can be accurately classified by coronary computed angiography. The lesion length measured by CCTA is longer than that assessed by invasive coronary angiography. (orig.)

  15. Value of multislice computed tomography angiography of the thorax in preparation for catheter ablation for the treatment of atrial fibrillation: The impact of unexpected cardiac and extracardiac findings on patient care

    Energy Technology Data Exchange (ETDEWEB)

    Wissner, Erik; Wellnitz, Clinton V.; Srivathsan, Komandoor; Scott, Luis R. [Mayo Clinic Arizona - Mayo Clinic Hospital, Cardiovascular Diseases, 5777 East Mayo Boulevard, Phoenix, AZ 85054 (United States); Altemose, Gregory T. [Mayo Clinic Arizona - Mayo Clinic Hospital, Cardiovascular Diseases, 5777 East Mayo Boulevard, Phoenix, AZ 85054 (United States)], E-mail: altemose.gregory@mayo.edu

    2009-11-15

    Objective: In patients referred for catheter ablation for the treatment of atrial fibrillation, multislice computed tomography angiography of the thorax is routinely performed to assess pulmonary vein anatomy. We sought to investigate the incidence of unexpected cardiac and extracardiac findings in this select patient population and to establish how these findings influence subsequent patient care. Methods: Ninety-five patients (mean age 62 {+-} 10 years, 35% female) referred to our institution for ablation therapy for atrial fibrillation between July 2003 and October 2007 underwent multislice computed tomography angiography of the thorax. Radiologists interpreted all images. Need for additional testing, consultation and eventual diagnosis were assessed by electronic record review. Results: A total of 83 (5 cardiac, 78 extracardiac) unexpected findings were observed in 50/95 (53%) of patients. The findings prompted 23 additional tests (5 cardiac, 18 noncardiac) in 15/95 (16%) of patients and 8 subsequent referrals in 7/95 (7%) patients. In 6 patients the findings significantly altered future patient care and resulted in postponement of ablation therapy in 4 patients. In 2 patients, extracardiac findings (pulmonary emboli and adenocarcinoma of the lung) were of potentially life-saving consequence. Conclusions: In patients undergoing multislice computed tomography angiography of the thorax in anticipation of planned catheter ablation therapy for the treatment of atrial fibrillation, unexpected findings are common and of potentially significant value. In comparison, there is a higher prevalence of unexpected extracardiac, rather than cardiac findings. Further investigation of these findings may lead to postponement of ablation therapy, but may also be of potentially lifesaving consequence.

  16. Value of multislice computed tomography angiography of the thorax in preparation for catheter ablation for the treatment of atrial fibrillation: The impact of unexpected cardiac and extracardiac findings on patient care

    International Nuclear Information System (INIS)

    Wissner, Erik; Wellnitz, Clinton V.; Srivathsan, Komandoor; Scott, Luis R.; Altemose, Gregory T.

    2009-01-01

    Objective: In patients referred for catheter ablation for the treatment of atrial fibrillation, multislice computed tomography angiography of the thorax is routinely performed to assess pulmonary vein anatomy. We sought to investigate the incidence of unexpected cardiac and extracardiac findings in this select patient population and to establish how these findings influence subsequent patient care. Methods: Ninety-five patients (mean age 62 ± 10 years, 35% female) referred to our institution for ablation therapy for atrial fibrillation between July 2003 and October 2007 underwent multislice computed tomography angiography of the thorax. Radiologists interpreted all images. Need for additional testing, consultation and eventual diagnosis were assessed by electronic record review. Results: A total of 83 (5 cardiac, 78 extracardiac) unexpected findings were observed in 50/95 (53%) of patients. The findings prompted 23 additional tests (5 cardiac, 18 noncardiac) in 15/95 (16%) of patients and 8 subsequent referrals in 7/95 (7%) patients. In 6 patients the findings significantly altered future patient care and resulted in postponement of ablation therapy in 4 patients. In 2 patients, extracardiac findings (pulmonary emboli and adenocarcinoma of the lung) were of potentially life-saving consequence. Conclusions: In patients undergoing multislice computed tomography angiography of the thorax in anticipation of planned catheter ablation therapy for the treatment of atrial fibrillation, unexpected findings are common and of potentially significant value. In comparison, there is a higher prevalence of unexpected extracardiac, rather than cardiac findings. Further investigation of these findings may lead to postponement of ablation therapy, but may also be of potentially lifesaving consequence.

  17. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  19. Effect of calcified plaques on estimation of arterial stenosis of lower extremity in diabetic foot patients using multislice computed tomography angiography

    International Nuclear Information System (INIS)

    Yu Xiaojing; Jin Yan; Wang Ge; Li Chunzhi; Zhang Yi; Ren Hua

    2013-01-01

    Objective: To investigate the impacts of calcified plaques on estimation of arterial stenosis of lower extremity in diabetic foot patients using 16 -slice computed tomography angiography (MSCTA). Materials and Methods: Thirty-five patients (representing 38 cases)underwent both MSCTA and digital subtraction angiography (DSA) examinations. The arteries of lower extremity were divided into 15 anatomic segments, and the degree of artery stenosis in each segment was classified as normal, mildly, moderately. severely or occluded. The extent of calcification in each segment was also assessed on cross -sectional image of MDCTA and was classified as absent, mildly, moderately, or severely. Using DSA as the standard reference, the sensitivity, specificity, accuracy, Youden index, positive predictive value and negative predictive value of MSCTA were calculated. Agreement between MSCTA and DSA was assessed by Cohen's kappa statistics. Results: In the noncalcified, mildly and moderately calcified segments of the artery above the knee, for the detection of segments that had more than mild stenosis, the sensitivity, specificity, accuracy. Youden index, positive predictive value and negative predictive value of MSCTA were 97.1%, 98.7%, 98.2%, 95.8%, 97.0% and 98.7%, respectively. In the severely calcified segments of the artery above the knee, for the detection of segments that had more than mild stenosis, the sensitivity, specificity, accuracy, Youden index, positive predictive value and negative predictive value of MSCTA were 96.3%, 93.8%, 94.7%, 90.1%, 89.7% and 97.8%, respectively. In the noncalcified, mildly and moderately calcified segments of the artery below the knee, for the detection of segments that had more than mild stenosis, the sensitivity, specificity, accuracy, Youden index, positive predictive value and negative predictive value of MSCTA were 95.1%, 93.2%, 94.1%, 88.3%, 93.4% and 94.9%, respectively. In the severely calcified segments of the artery below the

  20. Individual selection of X-ray tube settings in computed tomography coronary angiography: Reliability of an automated software algorithm to maintain constant image quality.

    Science.gov (United States)

    Durmus, Tahir; Luhur, Reny; Daqqaq, Tareef; Schwenke, Carsten; Knobloch, Gesine; Huppertz, Alexander; Hamm, Bernd; Lembcke, Alexander

    2016-05-01

    To evaluate a software tool that claims to maintain a constant contrast-to-noise ratio (CNR) in high-pitch dual-source computed tomography coronary angiography (CTCA) by automatically selecting both X-ray tube voltage and current. A total of 302 patients (171 males; age 61±12years; body weight 82±17kg, body mass index 27.3±4.6kg/cm(2)) underwent CTCA with a topogram-based, automatic selection of both tube voltage and current using dedicated software with quality reference values of 100kV and 250mAs/rotation (i.e., standard values for an average adult weighing 75kg) and an injected iodine load of 222mg/kg. The average radiation dose was estimated to be 1.02±0.64mSv. All data sets had adequate contrast enhancement. Average CNR in the aortic root, left ventricle, and left and right coronary artery was 15.7±4.5, 8.3±2.9, 16.1±4.3 and 15.3±3.9 respectively. Individual CNR values were independent of patients' body size and radiation dose. However, individual CNR values may vary considerably between subjects as reflected by interquartile ranges of 12.6-18.6, 6.2-9.9, 12.8-18.9 and 12.5-17.9 respectively. Moreover, average CNR values were significantly lower in males than females (15.1±4.1 vs. 16.6±11.7 and 7.9±2.7 vs. 8.9±3.0, 15.5±3.9 vs. 16.9±4.6 and 14.7±3.6 vs. 16.0±4.1 respectively). A topogram-based automatic selection of X-ray tube settings in CTCA provides diagnostic image quality independent of patients' body size. Nevertheless, considerable variation of individual CNR values between patients and significant differences of CNR values between males and females occur which questions the reliability of this approach. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.

    1989-01-01

    This paper reports on computed tomographic (CT) scanning which has improved computer-assisted imaging modalities for radiologic diagnosis. The advantage of this modality is its ability to image thin cross-sectional planes of the body, thus uncovering density information in three dimensions without tissue superposition problems. Because this enables vastly superior imaging of soft tissues in the brain and body, CT scanning was immediately successful and continues to grow in importance as improvements are made in speed, resolution, and cost efficiency. CT scanners are used for general purposes, and the more advanced machines are generally preferred in large hospitals, where volume and variety of usage justifies the cost. For imaging in the abdomen, a scanner with a rapid speed is preferred because peristalsis, involuntary motion of the diaphram, and even cardiac motion are present and can significantly degrade image quality. When contrast media is used in imaging to demonstrate scanner, immediate review of images, and multiformat hardcopy production. A second console is reserved for the radiologist to read images and perform the several types of image analysis that are available. Since CT images contain quantitative information in terms of density values and contours of organs, quantitation of volumes, areas, and masses is possible. This is accomplished with region-of- interest methods, which involve the electronic outlining of the selected region of the television display monitor with a trackball-controlled cursor. In addition, various image- processing options, such as edge enhancement (for viewing fine details of edges) or smoothing filters (for enhancing the detectability of low-contrast lesions) are useful tools

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  3. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  6. Coronary Computed Tomography Angiography (CTA)

    Science.gov (United States)

    ... coronary arteries, may also be administered as a tablet or spray underneath your tongue. While lying on ... the scanner at one time such as with MRI. If an intravenous contrast material is used, you ...

  7. Angiotomografía computerizada, colgajos de perforante, cirujano y OsiriX Computed tomography angiography, perforator flaps, surgeon and OsiriX

    Directory of Open Access Journals (Sweden)

    M. Rodríguez-Vegas

    2013-03-01

    consecuencia, parece aconsejable que el cirujano plástico relacionado con los colgajos de perforante se involucre decididamente en el postprocesamiento de las imágenes de angiotomografía computerizada. El visor de imágenes DICOM gratuito OsiriX es una alternativa eficiente, comparable a aplicaciones más profesionales sólo disponibles en servicios de Radiología.With the advent of perforator-based skin transfer, computed tomography angiography has emerged as an invaluable tool in the preoperative planning of perforator flaps. But most likely, the exploitation of the technique is less than desirable. Through our experience with 144 patients, we evaluate the use of the free DICOM viewer OsiriX for Mac in the preoperative planning of perforator flaps with three objectives: 1 increase the present knowledge related with the preoperative planning of perforator flaps with computed tomography angiography, 2 evaluate the OsiriX application in the image post-processing of perforator flaps and 3 evaluate the performance of the procedure when performed by a surgeon (not specialized in Radiology. The experience has shown that the image post-processing performed by the surgeon with the OsiriX application usually allows an adequate evaluation of different structures and parameters of great preoperative interest in perforator flap surgery: 1 source artery, 2 diameter of artery and vein/s at the hypothetical site of microsurgical anastomoses, 3 course and branching pattern of the flap pedicle, 4 perforator course in the subcutaneous fat (theoretical flap axis, 5 measurement of the skin and fat where the perforator pierces the deep fascia (theoretical flap thickness , 6 measurement of the distance between the point of entrance of the perforator in the subcutaneous fat to the source artery (theoretical maximal pedicle length and 7 measurement of the perforator diameter where it pierces the deep fascia. Ultimately, in the authors' opinion, those plastic surgeons involved in perforator flap

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  9. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  10. Association of traditional cardiovascular risk factors with coronary plaque sub-types assessed by 64-slice computed tomography angiography in a large cohort of asymptomatic subjects.

    Science.gov (United States)

    Rivera, Juan J; Nasir, Khurram; Cox, Pedro R; Choi, Eue-Keun; Yoon, Yeonyee; Cho, Iksung; Chun, Eun-Ju; Choi, Sang-Il; Blumenthal, Roger S; Chang, Hyuk-Jae

    2009-10-01

    Although prior studies have shown that traditional cardiovascular (CV) risk factors are associated with the burden of coronary atherosclerosis, less is known about the relationship of risk factors with coronary plaque sub-types. Coronary computed tomography angiography (CCTA) allows an assessment of both, total disease burden and plaque characteristics. In this study, we investigate the relationship between traditional CV risk factors and the presence and extent of coronary plaque sub-types in a large group of asymptomatic individuals. The study population consisted of 1015 asymptomatic Korean subjects (53+/-10 years; 64% were males) free of known CV disease who underwent 64-slice CCTA as part of a health screening evaluation. We analyzed plaque characteristics on a per-segment basis according to the modified American Heart Association classification. Plaques in which calcified tissue occupied more than 50% of the plaque area were classified as calcified (CAP), NCAP). A total of 215 (21%) subjects had coronary plaque while 800 (79%) had no identifiable disease. Multivariate regression analysis demonstrated that increased age (per decade) and gender are the strongest predictors for the presence of any coronary plaque or the presence of at least one segment of CAP and MCAP (any plaque-age: OR 2.89; 95% CI 2.34, 3.56; male gender: OR 5.21; 95% CI 3.20, 8.49; CAP-age: OR 2.75; 95% CI 2.12, 3.58; male gender: 4.78; 95% CI 2.48, 9.23; MCAP-age: OR 2.62; 95% CI 2.02, 3.39; male gender: OR 4.15; 95% CI 2.17, 7.94). The strongest predictors for the presence of any NCAP were gender (OR 3.56; 95% CI 1.96-6.55) and diabetes mellitus (OR 2.87; 95% CI 1.63-5.08). When looking at the multivariate association between the presence of >/=2 coronary segments with a plaque sub-type and CV risk factors, male gender was the strongest predictor for CAP (OR 7.31; 95% CI 2.12, 25.20) and MCAP (OR 5.54; 95% CI 1.84, 16.68). Alternatively, smoking was the strongest predictor for the presence

  11. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  12. [Evaluation of diabetic microangiopathy using optical coherence tomography angiography].

    Science.gov (United States)

    Czakó, Cecília; Sándor, Gábor László; Ecsedy, Mónika; Szepessy, Zsuzsanna; Borbándy, Ágnes; Resch, Miklós; Papp, András; Récsán, Zsuzsa; Horváth, Hajnalka; Nagy, Zoltán Zsolt; Kovács, Illés

    2018-02-01

    Optical coherence tomography angiography is a non-invasive imaging technique that is able to visualize the different retinal vascular layers using motion contrast to detect blood flow without intravenous dye injection. This method might help to assess microangiopathy in diabetic retinopathy during screening and follow-up. To quantify retinal microvasculature alterations in both eyes of diabetic patients in relation to systemic risk factors using optical coherence tomography angiography. Both eyes of 36 diabetic patients and 45 individuals without diabetes were examined. Duration of diabetes, insulin therapy, blood pressure, HbA 1c , dyslipidemia, axial length and the presence of diabetic retinopathy were recorded. Retinal vessel density was measured by optical coherence tomography angiography. The effect of risk factors on vessel density and between-eye asymmetry was assessed using multivariable regression analysis. Vessel density was significantly lower and between-eye difference was significantly higher in diabetic patients compared to controls (pdiabetes duration (pdiabetic retinopathy compared to control subjects (pdiabetes compared to healthy subjects. By using optical coherence tomography angiography, the detection of these microvascular alterations is possible before clinically detectable diabetic retinopathy and might serve as a useful tool in both screening and timing of treatment. Orv Hetil. 2018; 159(8): 320-326.

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  14. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  17. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  18. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  19. Computer assisted radionuclide angiography to confirm reversible ischemic cerebral dysfunction

    International Nuclear Information System (INIS)

    Buell, U.; Lanksch, W.; Tosch, U.; Kleinhans, E.; Steinhoff, H.

    1982-01-01

    Computer assisted radionuclide angiography (CARNA) was employed in patients with transient ischemic attack (TIA) or prolonged reversible ischemic neurologic deficit (PRIND) to establish the sensitivity of CARNA in detecting and quantifying changes of cerebral perfusion in such selected patients. Moreover, results of CARNA were compared with findings of cranial radiographic angiography (RGA) to obtain data on combined sensitivities of these methods. CARNA may be the preferred noninvasive procedure employed because it detects and quantifies the vascular supply disorder in patients with TIA and PRIND. If no computer assistance is used to evaluate cranial radionuclide angiography, results are considerable less accurate. Specifity of CARNA is 84.6%. If CARNA is negative (25.2% in TIA; 12.7% in PRIND), a further method must be employed to confirm the cranial vascular origin of the attack. This may be RGA in TIA and transmission computed axial tomography (T-CAT) T-CAT in PRIND. This diagnos - tic sequence lead to 92.4% true positive in TIA and to 93.2% true positives in PRIND

  20. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  1. Optical Coherence Tomography Angiography of Retinal Cavernous Hemangioma.

    Science.gov (United States)

    Pierro, Luisa; Marchese, Alessandro; Gagliardi, Marco; Bandello, Francesco

    2017-08-01

    Retinal cavernous hemangioma is a rare, benign, retinal tumor characterized by angiomatous proliferation of vessels within the inner retina or the optic disc.1 Here we report a case of retinal cavernous hemangioma on the margin of the optic disc in the right eye of a 61-year-old asymptomatic female. The lesion was studied with multimodal imaging which included structural optical coherence tomography, fluorescein angiography, blue fundus auto-fluorescence, optical coherence tomography angiography (OCTA) (DRI OCT Triton; Topcon, Tokyo, Japan) and visual field examination. Blood circulation inside retinal cavernous hemangioma lesion is typically low-stagnant.2 However, OCTA demonstrated blood flow inside the lesion, illustrating its vascular circulation.3 Visual field was within the normal limits, except from a slight enlargement of the blind spot. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:684-685.]. Copyright 2017, SLACK Incorporated.

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  11. Evaluation of a High Concentrated Contrast Media Injection Protocol in Combination with Low Tube Current for Dose Reduction in Coronary Computed Tomography Angiography: A Randomized, Two-center Prospective Study.

    Science.gov (United States)

    Sun, Yibo; Hua, Yanqing; Wang, Mingpeng; Mao, Dingbiao; Jin, Xiu; Li, Cheng; Shi, Kailei; Xu, Jianrong

    2017-12-01

    The study aimed to prospectively evaluate the radiation dose reduction potential and image quality (IQ) of a high-concentration contrast media (HCCM) injection protocol in combination with a low tube current (mAs) in coronary computed tomography angiography. Eighty-one consecutive patients (mean age: 62 years; 34 females; body mass index: 18-31) were included and randomized-assigned into two groups. All computed tomography (CT) examinations were performed in two groups with the same tube voltage (100 kV), flow rate of contrast medium (5.0 mL/s), and iodine dose (22.8 g). An automatic mAs and low concentration contrast medium (300 mgI/mL) were used in group A, whereas effective mAs was reduced by a factor 0.6 along with HCCM (400 mgI/mL) in group B. Radiation dose was assessed (CT dose index [CTDI vol ] and dose length product), and vessel-based objective IQ for various regions of interest (enhancement, noise, signal-to-noise ratio, and contrast-to-noise ratio), subjective IQ, noise, and motion artifacts were analyzed overall and vessel-based with a 5-point Likert scale. The CT attenuation of coronary arteries and image noise in group B were significantly higher than those in group A (ranges: 507.5-548.1 Hounsfield units vs 407.5-444.5 Hounsfield units; and 20.3 ± 8.6 vs 17.7 ± 8.0) (P ≤ 0.0166). There was no significant difference between the two groups in signal-to-noise ratio, contrast-to-noise ratio, and subjective IQ of coronary arteries (29.4-31.7, 30.0-37.0, and medium score of 5 in group A vs 29.4-32.4, 27.7-36.3, and medium score of 5 in group B, respectively, P ≥ 0.1859). Both mean CTDI vol and dose length product in group B were 58% of those of group A. HCCM combined with low tube current allows dose reduction in coronary computed tomography angiography and does not compromise IQ. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Computed tomography in hepatic trauma

    International Nuclear Information System (INIS)

    Moon, K.L. Jr.; Federle, M.P.

    1983-01-01

    Twenty-five patients with hepatic injury from blunt upper abdominal trauma were examined by computed tomography (CT). The spectrum of CT findings was recorded, and the size of the hepatic laceration and the associated hemoperitoneum were correlated with the mode of therapy used in each case (operative vs nonoperative). While the need for surgery correlated roughly with the size of the hepatic laceration, the size of the associated hemoperitoneum was an important modifying factor. Fifteen patients with hepatic lacerations but little or no hemoperitoneum were managed nonoperatively. CT seems to have significant advantages over hepatic scintigraphy, angiography, and diagnostic peritoneal lavage. By combining inforamtion on the clinical state of the patient and CT findings, therapy of hepatic injury can be individualized and the incidence of nontherapeutic laparotomies decreased

  13. Co-registration of optical coherence tomography and X-ray angiography in percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Hebsgaard, Lasse; Nielsen, Troels Munck; Tu, Shengxian

    2014-01-01

    Background Intracoronary imaging provides accurate lesion delineation and precise measurements for sizing and positioning of coronary stents. During percutaneous coronary intervention (PCI), it may be challenging to identify corresponding segments between intracoronary imaging and angiography....... Computer based online co-registration may aid the target segment identification. Methods The DOCTOR fusion study was a prospective, single arm, observational study including patients admitted for elective PCI. Optical coherence tomography (OCT) was acquired pre-stent implantation for sizing of stents...... to the computer-based co-registration, segments of the target lesion indicated on OCT were left uncovered by stent in 14 patients (70%). Conclusion Computer based online co-registration of OCT and angiography is feasible. Frequent inaccuracies in operator based registration indicate that computer aided co...

  14. Evaluation of image quality on a per-patient, per-vessel, and per-segment basis by noninvasive coronary angiography with 64-section computed tomography. Dual-source versus single-source computed tomography

    International Nuclear Information System (INIS)

    Nakashima, Yoshiteru; Okada, Munemasa; Washida, Yasuo; Miura, Toshiro; Fujimura, Tatsuo; Nao, Tomoko; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the image quality (IQ) of dual-source CT (DSCT) versus single-source CT (SSCT). A total of 100 patients underwent 64-section CT coronary angiography (50 DSCT, 50 SSCT). Three observers evaluated the IQ of each coronary segment using a four-point scale (1, excellent; 2, good; 3, fair; 4, no assessment). The IQ of DSCT coronary angiography was compared with SSCT coronary angiography on a per-patient, per-vessel, and per-segment basis using the chi-squared test. The DSCT image quality score (IQS) was significantly lower on a per-patient basis and per-vessel basis for all vessels and on a per-segment basis for some segments (1, 2, 4PD, 4AV, 7, 9, 11, 12, 13) compared with SSCT. The DSCT IQS was significantly lower for certain segments (2, 4PD, 11, 13) with high heart rates (≥70 beats/min). The DSCT IQS was significantly lower for certain segments (1, 2, 3, 4PD, 4AV, 7, 8, 9, 10, 12, 13) with low heart rates (<70 beats/min). DSCT showed a significantly better IQ than SSCT, especially in patients with low heart rates. (author)

  15. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris, E-mail: boris.schell@googlemail.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Heidenreich, Ralf, E-mail: ralf.heidenreich@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Heidenreich, Monika, E-mail: info@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Thalhammer, Axel, E-mail: axel.thalhammer@kgu.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Naeem, Naguib Nagy Naguib, E-mail: nagynnn@yahoo.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas Josef, E-mail: T.Vogl@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Zangos, Stefan, E-mail: Zangos@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany)

    2012-12-15

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  16. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications.

    Science.gov (United States)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-12-01

    To evaluate the radiation exposure for operating personnel associated with rotational flat-panel angiography and C-arm cone beam CT. Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8s/rotation, 20s/rotation and 5s/2 rotations), and 47 cm×18 cm (16s/2 rotations) and standard 2D angiography (10s, FOV 24 cm×18 cm). Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8s/rotation: 28.0 μSv, 20s/rotation: 79.3 μSv, 5s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20s/rotation). Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    International Nuclear Information System (INIS)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-01-01

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  18. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography

    International Nuclear Information System (INIS)

    Burgstahler, Christof; Reimann, Anja; Brodoefel, Harald; Tsiflikas, Ilias; Thomas, Christoph; Heuschmid, Martin; Daferner, Ulrike; Drosch, Tanja; Schroeder, Stephen; Herberts, Tina

    2009-01-01

    Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n=90; Siemens Sensation 64: n=91; Siemens Definition: n=75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347±13 vs. 254±14 (64-MSCT) vs. 233±11 (16-MSCT) HU], LM (362±11/275 ± 12/262±9), LAD (332±17/248±19/219±14) and LCX (310±12/210±13/221±10, all p<0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p<0.05). BMI had no impact on the CA ratio in DSCT only (p<0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a

  19. Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols

    International Nuclear Information System (INIS)

    Beitzke, D.; Berger-Kulemann, V.; Unterhumer, S.; Loewe, C.; Wolf, F.; Schoepf, V.; Spitzer, E.; Feuchtner, G.M.; Gyoengyoesi, M.; Uyanik-Uenal, K.; Zuckermann, A.

    2015-01-01

    To prospectively evaluate image quality (IQ) and radiation dose of dual-source cardiac computed tomography (CCTA) using different imaging protocols. CCTA was performed in 150 patients using the retrospective ECG-gated spiral technique (rECG) the prospective ECG-gated technique (pECG), or the prospective ECG-gated technique with systolic imaging and automated tube voltage selection (pECGsys). IQ was rated using a 16-segment coronary artery model. Techniques were compared for overall IQ, IQ of the large and the small coronary artery segments. Effective dose was used for comparison of radiation dose. Overall IQ and IQ of the large segments showed no differences between the groups. IQ analysis of the small segments showed lowered IQ in pECGsys compared to rECG (p = 0.02), but not to pECG (p = 0.6). Effective dose did not differ significantly between rECG and pECG (p = 0.13), but was significantly lower for pECGsys (p < 0.001 vs. rECG and pECG). Radiation dose of dual-source CCTA in heart transplant recipients is significantly reduced by using prospective systolic scanning and automated tube voltage selection, while overall IQ and IQ of the large coronary segments are maintained. IQ appears to be lower compared to retrospective techniques with regard to small coronary segments. (orig.)

  20. Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beitzke, D.; Berger-Kulemann, V.; Unterhumer, S.; Loewe, C.; Wolf, F. [Medical University Vienna, Department of Biomedical Imaging and Image Guided Therapy, Division of Cardiovascular and Interventional Radiology, Vienna (Austria); Schoepf, V. [Medical University Vienna, Department of Biomedical Imaging and Image Guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Spitzer, E. [Bern University Hospital, Department of Cardiology, Bern (Switzerland); Feuchtner, G.M. [Innsbruck Medical University, Department of Radiology II, Innsbruck (Austria); Gyoengyoesi, M. [Medical University Vienna, Department of Cardiology, Vienna (Austria); Uyanik-Uenal, K.; Zuckermann, A. [Medical University Vienna, Department of Cardiac Surgery, Vienna (Austria)

    2015-08-15

    To prospectively evaluate image quality (IQ) and radiation dose of dual-source cardiac computed tomography (CCTA) using different imaging protocols. CCTA was performed in 150 patients using the retrospective ECG-gated spiral technique (rECG) the prospective ECG-gated technique (pECG), or the prospective ECG-gated technique with systolic imaging and automated tube voltage selection (pECGsys). IQ was rated using a 16-segment coronary artery model. Techniques were compared for overall IQ, IQ of the large and the small coronary artery segments. Effective dose was used for comparison of radiation dose. Overall IQ and IQ of the large segments showed no differences between the groups. IQ analysis of the small segments showed lowered IQ in pECGsys compared to rECG (p = 0.02), but not to pECG (p = 0.6). Effective dose did not differ significantly between rECG and pECG (p = 0.13), but was significantly lower for pECGsys (p < 0.001 vs. rECG and pECG). Radiation dose of dual-source CCTA in heart transplant recipients is significantly reduced by using prospective systolic scanning and automated tube voltage selection, while overall IQ and IQ of the large coronary segments are maintained. IQ appears to be lower compared to retrospective techniques with regard to small coronary segments. (orig.)

  1. Coronary calcium score as gatekeeper for 64-slice computed tomography coronary angiography in patients with chest pain: per-segment and per-patient analysis

    International Nuclear Information System (INIS)

    Palumbo, Anselmo Alessandro; Cademartiri, Filippo; Maffei, Erica; Martini, Chiara; Tarantini, Giuseppe; Di Tanna, Gian Luca; Berti, Elena; Grilli, Roberto; Casolo, Giancarlo; Brambilla, Valerio; Cerrato, Marcella; Rotondo, Antonio; Weustink, Annick C.; Mollet, Nico R.A.

    2009-01-01

    We sought to investigate the performance of 64-slice CT in symptomatic patients with different coronary calcium scores. Two hundred patients undergoing 64-slice CT coronary angiography for suspected coronary artery disease were enrolled into five groups based on Agatston calcium score using the Mayo Clinic risk stratification: group 1: score 0, group 2: score 1-10, group 3: score 11-100, group 4: score 101-400, and group 5: score > 401. Diagnostic accuracy for the detection of significant (≥50% lumen reduction) coronary artery stenosis was assessed on a per-segment and per-patient base using quantitative coronary angiography as the gold standard. For groups 1 through 5, sensitivity was 97, 96, 91, 90, 92%, and specificity was 99, 98, 96, 88, 90%, respectively, on a per-segment basis. On a per-patient basis, the best diagnostic performance was obtained in group 1 (sensitivity 100% and specificity 100%) and group 5 (sensitivity 95% and specificity 100%). Progressively higher coronary calcium levels affect diagnostic accuracy of CT coronary angiography, decreasing sensitivity and specificity on a per-segment base. On a per-patient base, the best results in terms of diagnostic accuracy were obtained in the populations with very low and very high cardiovascular risk. (orig.)

  2. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, M.C., E-mail: mburgmans@hotmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Too, C.W., E-mail: too.chow.wei@singhealth.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Kao, Y.H., E-mail: yung.h.kao@gmail.com [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Goh, A.S.W., E-mail: anthony.goh.s.w@sgh.com.sg [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Chow, P.K.H., E-mail: gsupc@singnet.com.sg [Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore); Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore); Tan, B.S., E-mail: tan.bien.soo@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Lo, R.H.G., E-mail: richard.lo.h.g@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2012-12-15

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  3. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    International Nuclear Information System (INIS)

    Burgmans, M.C.; Too, C.W.; Kao, Y.H.; Goh, A.S.W.; Chow, P.K.H.; Tan, B.S.; Tay, K.H.; Lo, R.H.G.

    2012-01-01

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  4. 128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram-triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral Scan.

    Science.gov (United States)

    Lin, Lu; Wang, Yi-Ning; Kong, Ling-Yan; Jin, Zheng-Yu; Lu, Guang-Ming; Zhang, Zhao-Qi; Cao, Jian; Li, Shuo; Song, Lan; Wang, Zhi-Wei; Zhou, Kang; Wang, Ming

    2013-01-01

    Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequential scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrillation referred for a second-generation 128-slice DSCT coronary angiography were included in the prospective study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG-triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel-lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each patient were compared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean HR (t=1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by reader1 and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by reader1 and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27±0.19 vs. 1.25±0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  9. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  10. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  11. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  14. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  15. Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Renapurkar, Rahul D.; Azok, Joseph; Lempel, Jason; Karim, Wadih; Graham, Ruffin [Thoracic Imaging, L10, Imaging Institute, Cleveland Clinic, Cleveland, OH (United States); Primak, Andrew [Siemens Medical Solutions, Malvern, PA (United States); Tandon, Yasmeen [Case Western Reserve University-Metro Health Medical Center, Department of Radiology, Cleveland, OH (United States); Bullen, Jennifer [Quantitative Health Sciences, Cleveland Clinic, Cleveland, OH (United States); Dong, Frank [Section of Medical Physics, Cleveland Clinic, Cleveland, OH (United States)

    2017-08-15

    The purpose of this study was to evaluate the impact of attenuation-based kilovoltage (kV) pair selection in dual source dual energy (DSDE)-pulmonary embolism (PE) protocol examinations on radiation dose savings and image quality. A prospective study was carried out on 118 patients with suspected PE. In patients in whom attenuation-based kV pair selection selected the 80/140Sn kV pair, the pre-scan 100/140Sn CTDIvol (computed tomography dose index volume) values were compared with the pre-scan 80/140Sn CTDIvol values. Subjective and objective image quality parameters were assessed. Attenuation-based kV pair selection switched to the 80/140Sn kV pair (''switched'' cohort) in 63 out of 118 patients (53%). The mean 100/140Sn pre-scan CTDIvol was 8.8 mGy, while the mean 80/140Sn pre-scan CTDIvol was 7.5 mGy. The average estimated dose reduction for the ''switched'' cohort was 1.3 mGy (95% CI 1.2, 1.4; p < 0.001), representing a 15% reduction in dose. After adjusting for patient weight, mean attenuation was significantly higher in the ''switched'' vs. ''non-switched'' cohorts in all five pulmonary arteries and in all lobes on iodine maps. This study demonstrates that attenuation-based kV pair selection in DSDE examination is feasible and can offer radiation dose reduction without compromising image quality. (orig.)

  16. Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Cademartiri, Filippo; Palumbo, Alessandro; La Grutta, Ludovico; Runza, Giuseppe; Maffei, Erica; Mollet, Nico R.; Hamers, Ronald; Bruining, Nico; Bartolotta, Tommaso V.; Midiri, Massimo; Somers, Pamela; Knaapen, Michiel; Verheye, Stefan

    2007-01-01

    Attenuation variability (measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/∞) and a 1/50 solution of contrast material (400 mgI/ml iomeprol). Scan parameters were: slices/collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques and the surrounding oil. The results were compared by the ANOVA test and correlated with Pearson's test. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The mean attenuation values were significantly different between the four filters (p < 0.0001) in each structure with both solutions. After clustering for the filter, all of the noncalcified plaque values (20.8 ± 39.1, 14.2 ± 35.8, 14.0 ± 32.0, 3.2 ± 32.4 HU with saline; 74.7 ± 66.6, 68.2 ± 63.3, 66.3 ± 66.5, 48.5 ± 60.0 HU in contrast solution) were significantly different, with the exception of the pair b36f-b46f, for which a moderate-high correlation was generally found. Improved SNRs and CNRs were achieved by b30f and b46f. The use of different convolution filters significantly modified the attenuation values, while sharper filtering increased the calcified plaque attenuation and reduced the noncalcified plaque attenuation. (orig.)

  17. Early detection of lung cancer using ultra-low-dose computed tomography in coronary CT angiography scans among patients with suspected coronary heart disease.

    Science.gov (United States)

    Zanon, Matheus; Pacini, Gabriel Sartori; de Souza, Vinicius Valério Silveiro; Marchiori, Edson; Meirelles, Gustavo Souza Portes; Szarf, Gilberto; Torres, Felipe Soares; Hochhegger, Bruno

    2017-12-01

    To assess whether an additional chest ultra-low-dose CT scan to the coronary CT angiography protocol can be used for lung cancer screening among patients with suspected coronary artery disease. 175 patients underwent coronary CT angiography for assessment of coronary artery disease, additionally undergoing ultra-low-dose CT screening to early diagnosis of lung cancer in the same scanner (80kVp and 15mAs). Patients presenting pulmonary nodules were followed-up for two years, repeating low-dose CTs in intervals of 3, 6, or 12 months based on nodule size and growth rate in accordance with National Comprehensive Cancer Network guidelines. Ultra-low-dose CT identified 71 patients with solitary pulmonary nodules (41%), with a mean diameter of 5.50±4.00mm. Twenty-eight were >6mm, and in 79% (n=22) of these cases they were false positive findings, further confirmed by follow-up (n=20), resection (n=1), or biopsy (n=1). Lung cancer was detected in six patients due to CT screening (diagnostic yield: 3%). Among these, four cases could not be detected in the cardiac field of view. Most patients were in early stages of the disease. Two patients diagnosed at advanced stages died due to cancer complications. The addition of the ultra-low-dose CT scan represented a radiation dose increment of 1.22±0.53% (effective dose, 0.11±0.03mSv). Lung cancer might be detected using additional ultra-low-dose protocols in coronary CT angiography scans among patients with suspected coronary artery disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Application of optical coherence tomography angiography for diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Qing Liu

    2016-04-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new emerging technology of the optical coherence tomography(OCTin recent years. It's a noninvasive and fast retinal vascular imaging technology with high resolution, and has been gradually applied to make diagnosis, gives treatment and follow-up for various types of retinal vascular diseases, such as diabetic retinopathy, choroid neovascularization, etc. OCTA has the unique advantages of layered observing the structure and shape of the chorioretinal vascular at different levels, and quantifying the blood flow index of designated scope and the flow area of lesions. However, OCTA requires high solid vision and good cooperation of patients, even has the limitations to observe the retinal scope and retinal vascular barrier function. With overcoming these limitations, it's helpful for us to improve the understanding of retinal vascular diseases, consummate the diagnosis and treatment and observation of retinal vascular diseases.

  19. Computed tomography of cartilaginous tumours

    International Nuclear Information System (INIS)

    Marincek, B.; Triller, J.; Robotti, G.; Gumppenberg, S. von

    1984-01-01

    The compound tomography (CT) morphology of cartilaginous tumors and the utility of CT in their diagnostic work-up is presented on the basis of 19 cases. CT provided unique informations regarding definition of tumor extent and tumor relationship to adjacent structures particularly in the axial skeleton. CT has diminished the indications for angiography in cartilaginous tumors. (orig.) [de

  20. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  1. Three-dimensional (3D)- computed tomography bronchography and angiography combined with 3D-video-assisted thoracic surgery (VATS) versus conventional 2D-VATS anatomic pulmonary segmentectomy for the treatment of non-small cell lung cancer.

    Science.gov (United States)

    She, Xiao-Wei; Gu, Yun-Bin; Xu, Chun; Li, Chang; Ding, Cheng; Chen, Jun; Zhao, Jun

    2018-02-01

    Compared to the pulmonary lobe, the anatomical structure of the pulmonary segment is relatively complex and prone to variation, thus the risk and difficulty of segmentectomy is increased. We compared three-dimensional computed tomography bronchography and angiography (3D-CTBA) combined with 3D video-assisted thoracic surgery (3D-VATS) to perform segmentectomy to conventional two-dimensional (2D)-VATS for the treatment of non-small cell lung cancer (NSCLC). We retrospectively reviewed the data of randomly selected patients who underwent 3D-CTBA combined with 3D-VATS (3D-CTBA-VATS) or 2D-VATS at the Department of Thoracic Surgery, The First Affiliated Hospital of Soochow University Hospital, from January 2014 to May 2017. The operative duration of 3D group was significantly shorter than the 2D group (P 0.05). The extent of intraoperative bleeding and postoperative drainage in the 3D group was significantly lower than in the 2D group (P 3D group was shorter than in the 2D group (P 0.05). However, hemoptysis and pulmonary air leakage (>3d) occurred significantly less frequently in the 3D than in the 2D group (P 3D-CTBA-VATS is a more accurate and smooth technique and leads to reduced intraoperative and postoperative complications. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  2. Use of 3D-computed tomography angiography for planning the surgical removal of pineal region meningiomas using Poppen's approach: a report of ten cases and a literature review

    Directory of Open Access Journals (Sweden)

    Li Ye

    2011-06-01

    Full Text Available Abstract Background There are several treatment approaches for pineal region meningiomas, such as Poppen's approach, Krause's approach and combinations of the two approaches. We present our experience with the use of 3D-computed tomography angiography for planning the surgical removal of pineal region meningiomas using a suboccipital transtentorial approach (Poppen's approach and evaluate the role of Poppen's approach. Methods During the period from January 2005 to June 2010, ten patients presented to us with pineal region meningioma. MRI was routinely used to define the tumor size, position, and its relevant complications while 3D-CTA was applied to define the blood supply of the tumor and the venous complex (VC shift before operations. Most of the meningiomas had developed at both sides of the tentorial plane and extended laterally with typical characteristics of a pineal region tumor. Results All tumors were completely removed surgically without any injury to the VC. Postoperative intracranial infection occurred in one case who recovered after antibiotics were given. Postoperative intraventricular hemorrhage and pneumocephalus were found in one case, but fully recovered after conservative treatment. In the nine cases of concurrent hydrocephalus, this was gradually relieved in eight patients and the single case that became aggravated was successfully treated with ventriculoperitoneal shunt. Moreover, the follow-up MRI examinations did not indicate any recurrence of the meningiomas. Conclusion We found that the use of Poppen's approach is strongly supported for the successful removal of pineal region meningiomas without serious complications.

  3. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience; Angiotomografia computadorizada de coronarias com tomografo com 320 fileiras de detectores e utilizando o AIDR-3D: experiencia inicial

    Energy Technology Data Exchange (ETDEWEB)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao, E-mail: roberto.neto@einstein.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil); Failla, Bruna Bonaventura [Universidade Metodista de Sao Paulo, Sao Bernardo do Campo, SP (Brazil)

    2013-07-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  5. Use of postmortem coronary computed tomography angiography with water-insoluble contrast medium to detect stenosis of the left anterior descending artery in a case of sudden death.

    Science.gov (United States)

    Takahashi, Yoichiro; Sano, Rie; Takahashi, Keiko; Kominato, Yoshihiko; Takei, Hiroyuki; Kobayashi, Susumu; Shimada, Takehiro; Tokue, Hiroyuki; Awata, Sachiko; Hirasawa, Satoshi

    2016-03-01

    A 40-year-old man was found dead on a sidewalk in an expressway parking area one hour after he had entered the area on a motorcycle. A medicolegal autopsy was performed to reveal the cause of this sudden and unexpected death. Postmortem coronary CT angiography after introduction of 5% gelatin-barium emulsion as a radiopaque contrast medium into the heart demonstrated a significant arterial luminal filling defect in the left anterior descending (LAD) coronary artery. Macroscopic and microscopic examinations revealed that a thrombus had become deposited on ruptured plaque within the LAD artery, and that a small amount of the contrast medium was present between the thrombus and the vessel endothelium. These histological findings were consistent with incomplete occlusion of the LAD artery in the 3D reconstructed image. The cause of death in this case was definitively determined to be ischemic heart disease. Postmortem angiography played a role in screening of a vascular lesion that was subsequently verified by histology to have been responsible for sudden and unexpected death. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  7. Evaluation of resectability of renal cell carcinoma by computed tomography

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Matsumoto, Kunihiko; Tatezawa, Takashi; Kikuchi, Yoichi; Akisada, Masahiro; Kitagawa, Ryuichi

    1982-01-01

    Renal cell carcinoma is one of the unique neoplasm which is characterized by disappearing of the metastatic tumors after removal of the primary lesion. Angiography has been performed to evaluate the resectability of the primary tumor by nephrectomy in the past. With the use of computed tomography, detailed evaluation of the retroperitoneal structures is now possible. We have evaluated the resectability of renal cell tumor by computed tomography and compared the results with the angiographic findings and operative findings. Computed tomography is very accurate in determining the extent of the tumor especially in evaluation of tumor and the Gerota's fascia, which is essential to determine the resectability of the tumor. Informations about lymph node metastasis and invasion to the renal veins or inferior vena cava are also obtained.FIn most of the cases, angiography can be spared if computed tomography is properly performed. (author)

  8. E-learn Computed Tomographic Angiography

    DEFF Research Database (Denmark)

    Havsteen, Inger; Christensen, Anders; Nielsen, Jens K

    2012-01-01

    BACKGROUND: Computed tomographic angiography (CTA) is widely available in emergency rooms to assess acute stroke patients. To standardize readings and educate new readers, we developed a 3-step e-learning tool based on the test-teach-retest methodology in 2 acute stroke scenarios: vascular...... occlusion and "spot sign" in acute intracerebral hemorrhage. We hypothesized that an e-learning program enhances reading skills in physicians of varying experience. METHODS: We developed an HTML-based program with a teaching segment and 2 matching test segments. Tests were taken before and after...... sign correctly 69% before versus 92% after teaching (P = .009) and reported a median self-perceived diagnostic certainty of 50% versus 75% (P = .030). Self-perceived diagnostic certainty revealed no significant increase for vascular occlusion. CONCLUSIONS: The e-learning program is a useful educational...

  9. Computed Tomography. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Geleijns, J. [Leiden University Medical Centre, Leiden (Netherlands)

    2014-09-15

    After its clinical introduction in 1971, computed tomography (CT) developed from an X ray modality that was limited to axial imaging of the brain in neuroradiology into a versatile 3-D whole body imaging modality for a wide range of applications, including oncology, vascular radiology, cardiology, traumatology and interventional radiology. CT is applied for diagnosis and follow-up studies of patients, for planning of radiotherapy, and even for screening of healthy subpopulations with specific risk factors.

  10. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  11. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  12. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; Peterson, T.E.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented especially of the ball bearing races used in the rotation. (U.K.)

  13. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Brandt, R.T.; Hein, P.W.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. The tracks are supported on rollers which carry the substantial weight. Explicit engineering details are presented. (U.K.)

  14. ''In-house'' pharmacological management for computed tomography coronary angiography: heart rate reduction, timing and safety of different drugs used during patient preparation

    International Nuclear Information System (INIS)

    Maffei, Erica; Tedeschi, Carlo; Seitun, Sara; Ruffini, Livia; Aldrovandi, Annachiara; Palumbo, Alessandro A.; Martini, Chiara; Tarantini, Giuseppe; Weustink, Annick C.; Meijboom, Willem B.; Mollet, Nico R.; Krestin, Gabriel P.; Feyter, Pim J. de; Cademartiri, Filippo

    2009-01-01

    We retrospectively evaluated the effect, timing and safety of different pharmacological strategies during 64-slice CT coronary angiography (CT-CA). From the institutional database of CT-CA we enrolled 560 consecutive patients with suspected coronary artery disease. The type of drug preparation (group 1 = no treatment; group 2 = oral metoprolol; group 3 = other; group 4 = intravenous (IV) atenolol; group 5 = IV atenolol + nitrates; NR = non-responders), timing, and adverse effects were recorded. Heart rate (HR) during different preparation phases was recorded. Four adverse effects were recorded, none of which was attributable to pharmacological treatment. In all groups, except group 1, the HR on arrival was significantly reduced by the pharmacological treatment (p < 0.01). Group 4 showed the best (-16 ± 8 bpm) HR reduction. There was no significant effect on HR due to nitrates (p = 0.49), while a slight increase due to contrast material was noted (p < 0.05). Average time required for preparation was 44 ± 25 min. Groups 4 and 5 showed the most effective timing (8 ± 9 min and 8 ± 8 min, respectively; p < 0.01). Pharmacological preparation in patients undergoing CT-CA is safe and effective. Best results in terms of HR reduction and fast preparation are obtained with IV administration of beta-blockers. (orig.)

  15. ''In-house'' pharmacological management for computed tomography coronary angiography: heart rate reduction, timing and safety of different drugs used during patient preparation

    Energy Technology Data Exchange (ETDEWEB)

    Maffei, Erica; Tedeschi, Carlo; Seitun, Sara; Ruffini, Livia; Aldrovandi, Annachiara [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Palumbo, Alessandro A.; Martini, Chiara [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Tarantini, Giuseppe [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); University of Padua, Department of Cardiology, Padua (Italy); Weustink, Annick C.; Meijboom, Willem B.; Mollet, Nico R.; Krestin, Gabriel P.; Feyter, Pim J. de [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Cademartiri, Filippo [Azienda Ospedaliero - Universitaria di Parma, Department of Radiology and Cardiology, Parma (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Azienda Ospedaliero-Universitaria - Parma, Department of Radiology c/o Piastra Tecnica - Piano 0, Parma (Italy)

    2009-12-15

    We retrospectively evaluated the effect, timing and safety of different pharmacological strategies during 64-slice CT coronary angiography (CT-CA). From the institutional database of CT-CA we enrolled 560 consecutive patients with suspected coronary artery disease. The type of drug preparation (group 1 = no treatment; group 2 = oral metoprolol; group 3 = other; group 4 = intravenous (IV) atenolol; group 5 = IV atenolol + nitrates; NR = non-responders), timing, and adverse effects were recorded. Heart rate (HR) during different preparation phases was recorded. Four adverse effects were recorded, none of which was attributable to pharmacological treatment. In all groups, except group 1, the HR on arrival was significantly reduced by the pharmacological treatment (p < 0.01). Group 4 showed the best (-16 {+-} 8 bpm) HR reduction. There was no significant effect on HR due to nitrates (p = 0.49), while a slight increase due to contrast material was noted (p < 0.05). Average time required for preparation was 44 {+-} 25 min. Groups 4 and 5 showed the most effective timing (8 {+-} 9 min and 8 {+-} 8 min, respectively; p < 0.01). Pharmacological preparation in patients undergoing CT-CA is safe and effective. Best results in terms of HR reduction and fast preparation are obtained with IV administration of beta-blockers. (orig.)

  16. Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study.

    Science.gov (United States)

    Anand, Rishi; Gorev, Maxim V; Poghosyan, Hermine; Pothier, Lindsay; Matkins, John; Kotler, Gregory; Moroz, Sarah; Armstrong, James; Nemtsov, Sergei V; Orlov, Michael V

    2016-08-01

    To compare the efficacy and accuracy of rotational angiography with three-dimensional reconstruction (3DATG) image merged with electro-anatomical mapping (EAM) vs. CT-EAM. A prospective, randomized, parallel, two-center study conducted in 36 patients (25 men, age 65 ± 10 years) undergoing AF ablation (33 % paroxysmal, 67 % persistent) guided by 3DATG (group 1) vs. CT (group 2) image fusion with EAM. 3DATG was performed on the Philips Allura Xper FD 10 system. Procedural characteristics including time, radiation exposure, outcome, and navigation accuracy were compared between two groups. There was no significant difference between the groups in total procedure duration or time spent for various procedural steps. Minor differences in procedural characteristics were present between two centers. Segmentation and fusion time for 3DATG or CT-EAM was short and similar between both centers. Accuracy of navigation guided by either method was high and did not depend on left atrial size. Maintenance of sinus rhythm between the two groups was no different up to 24 months of follow-up. This study did not find superiority of 3DATG-EAM image merge to guide AF ablation when compared to CT-EAM fusion. Both merging techniques result in similar navigation accuracy.

  17. Effect of collateral circulation on myocardial protection in patients with acute myocardial infarction. Comparison of technetium-99m-tetrofosmin myocardial single photon emission computed tomography and coronary angiography

    International Nuclear Information System (INIS)

    Yoshida, Michi; Kondo, Makoto; Abe, Yoshiteru; Kubota, Tomoyuki; Matsuoka, Ryota; Araki, Makoto; Tanio, Hitoshi; Doyama, Kiyoshi

    2006-01-01

    Evaluation of myocardial blood flow from collateral vessels into the infarct area has been estimated by coronary angiography. In patients with acute myocardial infarction with Thrombolysis in Myocardial Infarction (TIMI) 0 flow, myocardial tracer uptake on single photon emission computed tomography (SPECT) images can predict the collateral blood flow in the infarct area if technetium (Tc)-99m-tetrofosmin was administered before recanalization. The present study investigated whether collateral blood flow evaluated by myocardial scintigraphy is a good predictor of myocardial salvage in patients with acute myocardial infarction. The study group consisted of 30 patients (mean age 65±14 years, 23 males, 7 females) with first acute myocardial infarction and coronary angiography evidence of total occlusion (TIMI 0) within 12 hr after the onset. All patients had one vessel disease related to infarction and TIMI 3 flow after percutaneous coronary intervention (PCI). Tc-99m-tetrofosmin was injected intravenously before the PCI. The regional severity score index (RSSI) was obtained from SPECT using the 17 segment method with the four-point scoring system. Myocardial viability was evaluated by the RSSI obtained from thallium-glucose-insulin infusion SPECT after 1 week and regional wall motion score index obtained from echocardiography during the chronic phase. The patients were divided into two groups according to the angiographic collateral finding. There were no differences in RSSI on thallium-glucose-insulin SPECT and regional wall motion score between the good collateral group (n=8) and poor collateral group (n=22). Myocardial Tc-99m-tetrofosmin RSSI was similar in these groups. On the other hand, the patients were divided according to Tc-99m-tetrofosmin scintigraphic evaluation before PCI. RSSI on thallium-glucose-insulin SPECT was significantly greater (0.7±0.5 vs 1.5±0.4, p<0.01) and regional wall motion score was significantly less (1.46±0.50 vs 2.08±0.78, p<0

  18. Comparison of anterior segment optical coherence tomography angiography and fluorescein angiography for iris vasculature analysis.

    Science.gov (United States)

    Zett, Claudio; Stina, Deborah M Rosa; Kato, Renata Tiemi; Novais, Eduardo Amorim; Allemann, Norma

    2018-04-01

    The aim of this study is to perform imaging of irises of different colors using spectral domain anterior segment optical coherence tomography angiography (AS-OCTA) and iris fluorescein angiography (IFA) and compare their effectiveness in examining iris vasculature. This is a cross-sectional observational clinical study. Patients with no vascular iris alterations and different pigmentation levels were recruited. Participants were imaged using OCTA adapted with an anterior segment lens and IFA with a confocal scanning laser ophthalmoscope (cSLO) adapted with an anterior segment lens. AS-OCTA and IFA images were then compared. Two blinded readers classified iris pigmentation and compared the percentage of visible vessels between OCTA and IFA images. Twenty eyes of 10 patients with different degrees of iris pigmentation were imaged using AS-OCTA and IFA. Significantly more visible iris vessels were observed using OCTA than using FA (W = 5.22; p Iris pigmentation was negatively correlated to the percentage of visible vessels in both imaging methods (OCTA, rho = - 0.73, p iris vasculature. In both AS-OCTA and IFA, iris pigmentation caused vasculature imaging blockage, but AS-OCTA provided more detailed iris vasculature images than IFA. Additional studies including different iris pathologies are needed to determine the most optimal scanning parameters in OCTA of the anterior segment.

  19. Potential applications of optical coherence tomography angiography in glaucoma.

    Science.gov (United States)

    Dastiridou, Anna; Chopra, Vikas

    2018-05-01

    Optical coherence tomography angiography (OCTA) is a novel, noninvasive imaging modality that allows assessment of the retinal and choroidal vasculature. The scope of this review is to summarize recent studies using OCTA in glaucoma and highlight potential applications of this new technology in the field of glaucoma. OCTA studies have shown that retinal vascular changes may not develop solely as a result of advanced glaucoma damage. OCTA-derived measurements have provided evidence for lower retinal vascular densities at the optic nerve head, peripapillary and macula in preperimetric-glaucoma and early-glaucoma, as well as, in more advanced glaucoma, in comparison to with normal eyes. OCTA is a novel imaging modality that has already started to expand our knowledge base regarding the role of ocular blood flow in glaucoma. Future studies will better elucidate the role of OCTA-derived measurements in clinical practice, research, and clinical trials in glaucoma.

  20. Reduction of metal artifacts due to dental hardware in computed tomography angiography: assessment of the utility of model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kuya, Keita; Shinohara, Yuki; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Kato, Ayumi [Tottori Municipal Hospital, Department of Radiology, Yonago (Japan); Sakamoto, Makoto; Kurosaki, Masamichi [Tottori University, Division of Neurosurgery, Department of Neurological Sciences, Faculty of Medicine, Yonago (Japan)

    2017-03-15

    The aim of this study is to assess the value of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) for reduction of metal artifacts due to dental hardware in carotid CT angiography (CTA). Thirty-seven patients with dental hardware who underwent carotid CTA were included. CTA was performed with a GE Discovery CT750 HD scanner and reconstructed with filtered back projection (FBP), ASIR, and MBIR. We measured the standard deviation at the cervical segment of the internal carotid artery that was affected most by dental metal artifacts (SD{sub 1}) and the standard deviation at the common carotid artery that was not affected by the artifact (SD{sub 2}). We calculated the artifact index (AI) as follows: AI = [(SD{sub 1})2 - (SD{sub 2})2]1/2 and compared each AI for FBP, ASIR, and MBIR. Visual assessment of the internal carotid artery was also performed by two neuroradiologists using a five-point scale for each axial and reconstructed sagittal image. The inter-observer agreement was analyzed using weighted kappa analysis. MBIR significantly improved AI compared with FBP and ASIR (p < 0.001, each). We found no significant difference in AI between FBP and ASIR (p = 0.502). The visual score of MBIR was significantly better than those of FBP and ASIR (p < 0.001, each), whereas the scores of ASIR were the same as those of FBP. Kappa values indicated good inter-observer agreements in all reconstructed images (0.747-0.778). MBIR resulted in a significant reduction in artifact from dental hardware in carotid CTA. (orig.)

  1. Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography

    International Nuclear Information System (INIS)

    D'Angelo, Tommaso; ''G. Martino'' University Hospital, Messina; Bucher, Andreas M.; Lenga, Lukas; Arendt, Christophe T.; Peterke, Julia L.; Martin, Simon S.; Leithner, Doris; Vogl, Thomas J.; Wichmann, Julian L.; Caruso, Damiano; University Hospital, Latina; Mazziotti, Silvio; Blandino, Alfredo; Ascenti, Giorgio; University Hospital, Messina; Othman, Ahmed E.

    2018-01-01

    To define optimal window settings for displaying virtual monoenergetic images (VMI) of dual-energy CT pulmonary angiography (DE-CTPA). Forty-five patients who underwent clinically-indicated third-generation dual-source DE-CTPA were retrospectively evaluated. Standard linearly-blended (M 0 .6), 70-keV traditional VMI (M70), and 40-keV noise-optimised VMI (M40+) reconstructions were analysed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with pulmonary artery attenuation to calculate separate optimised values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures of variance were performed to compare W/L settings and IQ indices between M 0 .6, M70, and M40+. B-W/L and O-W/L for M70 were 460/140 and 450/140, and were 1100/380 and 1070/380 for M40+, respectively, differing from standard DE-CTPA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding vascular contrast, embolism demarcation, and overall IQ (all p<0.001). Application of O-W/L settings is beneficial to optimise subjective IQ of VMI reconstructions of DE-CTPA. A width slightly less than two times the pulmonary trunk attenuation and a level approximately of overall pulmonary vessel attenuation are recommended. (orig.)

  2. Reduction of metal artifacts due to dental hardware in computed tomography angiography: assessment of the utility of model-based iterative reconstruction

    International Nuclear Information System (INIS)

    Kuya, Keita; Shinohara, Yuki; Ogawa, Toshihide; Kato, Ayumi; Sakamoto, Makoto; Kurosaki, Masamichi

    2017-01-01

    The aim of this study is to assess the value of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) for reduction of metal artifacts due to dental hardware in carotid CT angiography (CTA). Thirty-seven patients with dental hardware who underwent carotid CTA were included. CTA was performed with a GE Discovery CT750 HD scanner and reconstructed with filtered back projection (FBP), ASIR, and MBIR. We measured the standard deviation at the cervical segment of the internal carotid artery that was affected most by dental metal artifacts (SD_1) and the standard deviation at the common carotid artery that was not affected by the artifact (SD_2). We calculated the artifact index (AI) as follows: AI = [(SD_1)2 - (SD_2)2]1/2 and compared each AI for FBP, ASIR, and MBIR. Visual assessment of the internal carotid artery was also performed by two neuroradiologists using a five-point scale for each axial and reconstructed sagittal image. The inter-observer agreement was analyzed using weighted kappa analysis. MBIR significantly improved AI compared with FBP and ASIR (p < 0.001, each). We found no significant difference in AI between FBP and ASIR (p = 0.502). The visual score of MBIR was significantly better than those of FBP and ASIR (p < 0.001, each), whereas the scores of ASIR were the same as those of FBP. Kappa values indicated good inter-observer agreements in all reconstructed images (0.747-0.778). MBIR resulted in a significant reduction in artifact from dental hardware in carotid CTA. (orig.)

  3. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  4. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen, E-mail: zhengmw2007@163.com; Liu, Ying, E-mail: yingyinglyly@126.com; Wei, Mengqi, E-mail: weimengqi2008@163.com; Wu, Yongjie, E-mail: wu18291988526@163.com; Zhao, Hongliang, E-mail: zhaohl1980@163.com; Li, Jian, E-mail: xjyylj@yeah.net

    2014-02-15

    Objectives: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality and radiation dose of coronary CT angiography (cCTA) by using a combination of iterative reconstruction (IR) and low-tube-voltage technique. Materials and methods: One hundred patients were prospectively randomized to two types of contrast medium and underwent prospective electrocardiogram-triggering cCTA (Definition Flash, Siemens Healthcare; collimation: 128 mm × 0.6 mm; tube current: 300 mA s). Fifty patients received Iopromide 370 were scanned using the conventional tube setting (100 kVp or 120 kVp if BMI ≥ 25 kg/m{sup 2}) and reconstructed with filtered back projection (FBP). Fifty patients received Iodixanol 270 were scanned using the low-tube-voltage (80 kVp or 100 kVp if BMI ≥ 25 kg/m{sup 2}) technique and reconstructed with IR. CT attenuation was measured in coronary artery and other anatomical regions. Noise, image quality and radiation dose were compared. Results: Compared with two Iopromide 370 subgroups, Iomeprol 270 subgroups showed no significant difference in CT attenuation (576.63 ± 95.50 vs. 569.51 ± 118.93 for BMI < 25 kg/m{sup 2}, p = 0.647 and 394.19 ± 68.09 vs. 383.72 ± 63.11 for BMI ≥ 25 kg/m{sup 2}, p = 0.212), noise (in various anatomical regions of interest) and image quality (3.5 vs. 4.0, p = 0.13), but significantly (0.41 ± 0.17 vs. 0.94 ± 0.45 for BMI < 25 kg/m{sup 2}, p < 0.001 and 1.14 ± 0.24 vs. 2.37 ± 0.69 for BMI ≥ 25 kg/m{sup 2}, p < 0.001) lower radiation dose, which reflects dose saving of 56.4% and 51.9%, respectively. Conclusions: Combined IR with low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/ml can still maintain the contrast enhancement without impairing image quality, as well as significantly lower the radiation dose.

  5. Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

    Energy Technology Data Exchange (ETDEWEB)

    Dudeck, O., E-mail: oliver.dudeck@med.ovgu.de [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Schnapauff, D. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Herzog, L.; Löwenthal, D.; Bulla, K.; Bulla, B. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Halloul, Z.; Meyer, F. [University of Magdeburg, Department of General, Visceral and Vascular Surgery (Germany); Pech, M. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Gebauer, B. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Ricke, J. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany)

    2015-02-15

    PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

  6. Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.

    Science.gov (United States)

    Qi, Li; Zhao, Yan'E; Zhou, Chang Sheng; Spearman, James V; Renker, Matthias; Schoepf, U Joseph; Zhang, Long Jiang; Lu, Guang Ming

    2015-06-01

    Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Agreement of duplex ultrasonography vs. computed tomography angiography for evaluation of native and in-stent SFA re-stenosis—Findings from a randomized controlled trial

    International Nuclear Information System (INIS)

    Langenberger, Herbert; Schillinger, Martin; Plank, Christina; Sabeti, Schila; Dick, Petra; Cejna, Manfred; Lammer, Johannes; Minar, Erich; Loewe, Christian

    2012-01-01

    Background: Multidetector CT angiography (CTA) is a non-invasive imaging technique for evaluation of peripheral vascular disease. CTA might be particularly useful for assessment of intermediate- and long-term morphological outcome after endovascular treatment. Validation of CTA vs. the current imaging standard, colour Doppler ultrasonography (CDUS), for quantification of native and in-stent re-stenosis in the superficial femoral artery (SFA) is required. Methods: Seventy randomized patients who underwent stent implantation (n = 47) or balloon angioplasty (n = 23) underwent 6-month follow-up with CDUS and CTA. CTA was compared with CDUS in both sub-groups of patients in terms of binary re-stenosis (>50% lumen narrowing) and re-occlusion. Agreement between CTA and CDUS was assessed using Kappa (κ) statistics with 95% confidence intervals, and correlation coefficients. Results: Binary re-stenosis was detected in 16/70 (22.9%) patients by CTA and 17/70 (24.3%) patients by CDUS (κ = 0.88, 95% CI: 0.80–0.96). Re-stenosis rates after balloon angioplasty were 39.1% (9/23) on CTA and CDUS (κ = 0.82, 95% CI: 0.66–0.98), and after stent implantation 14.9% (7/47) on CTA and 17.0% (8/47) on CDUS (κ = 0.92, 95% CI: 0.84–1.00). Re-occlusions were detected in 3/70 (4.3%) patients by both CTA and CDUS (κ = 0.65; 95% CI 0.54–0.76). Significant correlations (r = 0.85, p < 0.001) were noted between degree of re-stenosis on CTA and peak velocity ratio on CDUS. The correlation coefficient was higher in patients after balloon angioplasty (r = 0.94, p < 0.001) than in patients after stent implantation (r = 0.71, p < 0.001). Conclusion: CTA and CDUS show excellent agreement for evaluation of native and in-stent re-stenosis after endovascular treatment of SFA obstructions. CTA is an appropriate non-invasive imaging modality for follow-up after endovascular therapy

  8. Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate

    International Nuclear Information System (INIS)

    Kishimoto, Miori; Doi, Shoko; Shimizu, Junichiro; Lee, Ki-Ja; Iwasaki, Toshiroh; Miyake, Yoh-Ichi; Yamada, Kazutaka

    2010-01-01

    Purpose: To evaluate the influence of osmolarity of iodinated contrast media and saline flush on the contrast effect in thoracic computed tomography angiography (CTA) at an identical iodine delivery rate (IDR). Materials and methods: Seven beagles were used in a cross-over experiment. The contrast media used were iohexol 350 mgI/ml (IOH350; osmolarity 844 mmol/kg) and iodixanol 320 mgI/ml (IDX320; osmolarity 290 mmol/kg). Each contrast medium was administered to groups with and without saline flush at 40.0 mgI/kg/s for all experiments. Dynamic CT scanning was performed at the ninth thoracic vertebra level. The peak value, area under the curve (AUC), and time to peak (TTP) were calculated from the time attenuation curves of the pulmonary artery and aorta. Results: There was no significant difference between IOH350 and IDX320 with or without saline flush in the peak values for the pulmonary artery and aorta. AUC was significantly higher in groups with saline flush for both contrast media and arteries (p < 0.05) with no significant difference between contrast media. TTP was significantly longer in groups with saline flush than without saline flush for both contrast media and arteries (p < 0.05), with no significant difference between contrast media. Conclusions: There were no significant differences in the contrast effects of monomeric IOH350 and dimeric IDX320 in thoracic CTA when used at an identical IDR. Moreover, saline flush prolonged the peak duration at 600 mgI/kg.

  9. Diagnostic value of 123I-betamethyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) in patients with chest pain. Comparison with rest-stress 99mTc-tetrofosmin SPECT and coronary angiography

    International Nuclear Information System (INIS)

    Kawai, Yuko; Nozaki, Yoichi; Ohkusa, Takanori; Sakurai, Masayuki; Morita, Koichi; Tamaki, Nagara

    2004-01-01

    Basic and clinical studies have indicated that 15-(p-[ 123 I] iodophenyl)-3-(R, S) methylpentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) can identify ischemic myocardium without evidence of myocardial infarction by the regional decline of tracer uptake. The present study compared BMIPP SPECT with rest-stress myocardial perfusion imaging (MPI) findings and coronary angiography (CAG) in 150 patients with acute chest pain. Patients with acute chest pain who underwent all of the following tests were selected: MPI at rest-stress, BMIPP SPECT at rest and CAG. Organic coronary artery stenosis (≥75%) was observed in 46 patients, 27 patients had total or subtotal coronary occlusion by spasm in the spasm provocation test on CAG and the remaining 77 patients had no significant coronary artery stenosis or spasm. The sensitivity of BMIPP at rest to detect organic stenosis was significantly higher (54%) than that of rest-MPI (33%, p<0.005), but lower than that of stress-MPI (76%, p=0.05). The sensitivity of BMIPP at rest to detect spasm was significantly higher (63%) than that of both rest-MPI (15%; p<0.001) and stress-MPI (19%; p<0.001). Overall, the sensitivity of BMIPP at rest to detect both organic stenosis and spasm was significantly higher (58%) than that of rest-MPI (26%; p<0.001), despite having no significance with that of stress-MPI (55%). The specificity was not significantly different among the three imaging techniques. Resting BMIPP SPECT is an alternative method to stress MPI for identifying patients with not only organic stenosis but also spasm without the need for a stress examination. (author)

  10. Computed tomography device

    International Nuclear Information System (INIS)

    Ohhashi, A.

    1985-01-01

    A computed tomography device comprising a subtraction unit which obtains differential data strings representing the difference between each time-serial projection data string of a group of projection data strings corresponding to a prospective reconstruction image generated by projection data strings acquired by a data acquisition system, a convolution unit which convolves each time-serial projection data string of the group of projection data strings corresponding to the prospective reconstruction image, and a back-projection unit which back-projects the convolved data strings

  11. Method for computed tomography

    International Nuclear Information System (INIS)

    Wagner, W.

    1980-01-01

    In transversal computer tomography apparatus, in which the positioning zone in which the patient can be positioned is larger than the scanning zone in which a body slice can be scanned, reconstruction errors are liable to occur. These errors are caused by incomplete irradiation of the body during examination. They become manifest not only as an incorrect image of the area not irradiated, but also have an adverse effect on the image of the other, completely irradiated areas. The invention enables reduction of these errors

  12. Dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzia, A.E.

    2014-01-01

    Objective: The amount of computed tomography (CT) studies that are performed each year in the world is growing exponentially mainly due to the incorporation of multislice CT that allows studies in a few seconds. But, despite the benefit received by patients with the diagnosis, radiation dose is a concern in the professional community and it has be reduced as much as reasonably possible. This article describes the main dosimetric CT units used in order to work with this practice easily, using the values that provide modern equipment and internationally known reference levels. (authors) [es

  13. Use of Coronary Computed Tomographic Angiography to Guide Management of Patients With Coronary Disease

    Science.gov (United States)

    Williams, Michelle C.; Hunter, Amanda; Shah, Anoop S.V.; Assi, Valentina; Lewis, Stephanie; Smith, Joel; Berry, Colin; Boon, Nicholas A.; Clark, Elizabeth; Flather, Marcus; Forbes, John; McLean, Scott; Roditi, Giles; van Beek, Edwin J.R.; Timmis, Adam D.; Newby, David E.

    2016-01-01

    Background In a prospective, multicenter, randomized controlled trial, 4,146 patients were randomized to receive standard care or standard care plus coronary computed tomography angiography (CCTA). Objectives The purpose of this study was to explore the consequences of CCTA-assisted diagnosis on invasive coronary angiography, preventive treatments, and clinical outcomes. Methods In post hoc analyses, we assessed changes in invasive coronary angiography, preventive treatments, and clinical outcomes using national electronic health records. Results Despite similar overall rates (409 vs. 401; p = 0.451), invasive angiography was less likely to demonstrate normal coronary arteries (20 vs. 56; hazard ratios [HRs]: 0.39 [95% confidence interval (CI): 0.23 to 0.68]; p coronary artery disease (283 vs. 230; HR: 1.29 [95% CI: 1.08 to 1.55]; p = 0.005) in those allocated to CCTA. More preventive therapies (283 vs. 74; HR: 4.03 [95% CI: 3.12 to 5.20]; p coronary heart disease, CCTA leads to more appropriate use of invasive angiography and alterations in preventive therapies that were associated with a halving of fatal and non-fatal myocardial infarction. (Scottish COmputed Tomography of the HEART Trial [SCOT-HEART]; NCT01149590) PMID:27081014

  14. Mesenteric panniculitis: computed tomography aspects

    International Nuclear Information System (INIS)

    Moreira, Luiza Beatriz Melo; Alves, Jose Ricardo Duarte; Marchiori, Edson; Pinheiro, Ricardo Andrade; Melo, Alessandro Severo Alves de; Noro, Fabio

    2001-01-01

    Mesenteric panniculitis is an inflammatory process that represents the second stage of a rare progressive disease involving the adipose tissue of the mesentery. Imaging methods used in the diagnosis of mesenteric panniculitis include barium studies, ultrasonography, computed tomography and magnetic resonance imaging. Computed tomography is important for both, diagnosis and evaluation of the extension of the disease and treatment monitoring. Computed tomography findings may vary according to the stage of the disease and the amount of inflammatory material or fibrosis. There is also good correlation between the computed tomography and anatomical pathology findings. The authors studied 10 patients with mesenteric panniculitis submitted to computed tomography. Magnetic resonance imaging was also performed in one patient. In all patients, computed tomography revealed a heterogeneous mass in the mesentery with density of fat, interspersed with areas of soft tissue density and dilated vessels. (author)

  15. The neutron computer tomography

    International Nuclear Information System (INIS)

    Matsumoto, G.; Krata, S.

    1983-01-01

    The method of computer tomography (CT) was applied for neutrons instead of X-rays. The neutron radiography image of samples was scanned by microphotometer to get the transmission data. This process was so time-consuming that the number of incident angles to samples could not be increased. The transmission data was processed by FACOM computer and CT image was gained. In the experiment at the Japan Research Reactor No. 4 at Tokai-mura with 18 projection angles, the resolution of paraffin in the aluminum block was less than 0.8 mm. In the experiment at Van de Graaf accelerator of Nagoya University, this same resolution was 1.2 mm because of the angle distribution of neutron beam. This experiment is the preliminary one, the facility which utilizes neutron television and video-recorder will be necessary for the next stage. (Auth.)

  16. Gantry for computed tomography

    International Nuclear Information System (INIS)

    Kelman, A.L.; O'Dell, W.R.; Brook, R.F.; Hein, P.W.; Brandt, R.T.

    1981-01-01

    A novel design of gantry for use in computed tomography is described in detail. In the new gantry, curved tracks are mounted to the laterally spaced apart sides of the frame which rotates and carries the detector and X-ray source. This permits the frame to be tilted either side of vertical enabling angular slices of body layers to be viewed and allows simplification of the algorithm which the computer uses for image reconstruction. A failsafe, solenoid brake is described which can lock the shaft against rotation. The gantry also contains a hoist mechanism which aids maintenance of the heavy X-ray tube and/or detector arrays. Explicit engineering details are presented. (U.K.)

  17. The application of optical coherence tomography angiography in retinal diseases.

    Science.gov (United States)

    Sambhav, Kumar; Grover, Sandeep; Chalam, Kakarla V

    Optical coherence tomography angiography (OCTA) is a new, noninvasive imaging technique that generates real-time volumetric data on chorioretinal vasculature and its flow pattern. With the advent of high-speed optical coherence tomography, established enface chorioretinal segmentation, and efficient algorithms, OCTA generates images that resemble an angiogram. The principle of OCTA involves determining the change in backscattering between consecutive B-scans and then attributing the differences to the flow of erythrocytes through retinal blood vessels. OCTA has shown promise in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age-related macular degeneration, and retinal vascular occlusions. It quantifies vascular compromise reflecting the severity of diabetic retinopathy. OCTA detects the presence of choroidal neovascularization in exudative age-related macular degeneration and maps loss of choriocapillaris in nonexudative age-related macular degeneration. We describe principles of OCTA and findings in common and some uncommon retinal pathologies. Finally, we summarize its potential future applications. Its current limitations include a relatively small field of view, inability to show leakage, and a tendency for image artifacts. Further larger studies will define OCTAs utility in clinical settings and establish if the technology may offer its utility in decreasing morbidity through early detection and guide therapeutic interventions in retinal diseases. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... cavities (ventricles) in patients with hydrocephalus . diseases or malformations of the skull. CT scanning is also performed ... biopsy ) from the brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more ...

  19. Exercise transcutaneous oxygen pressure measurement has good sensitivity and specificity to detect lower extremity arterial stenosis assessed by computed tomography angiography

    OpenAIRE

    Koch, Caroline; Chauve, Emmanuel; Chaudru, S?gol?ne; Le Faucheur, Alexis; Jaquinandi, Vincent; Mah?, Guillaume

    2016-01-01

    Abstract Peripheral artery disease (PAD) is a highly prevalent disease diagnosed by the use of ankle-brachial index (ABI) at rest. In some clinical conditions (diabetes, renal insufficiency, advanced age), ABI can be falsely normal and other tests are required for the PAD diagnosis (American Heart Association statement). This study was conducted to determine the accuracy of exercise transcutaneous oxygen pressure measurement (exercise-TcPo2) in detection of arterial stenosis ?50% using comput...

  20. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  1. Diabetic Macular Ischemia Diagnosis: Comparison between Optical Coherence Tomography Angiography and Fluorescein Angiography

    Directory of Open Access Journals (Sweden)

    Jose Mauricio Botto de Barros Garcia

    2016-01-01

    Full Text Available Purpose. To compare fluorescein angiography (FA and optical coherence tomography angiography (OCTA images of foveal avascular zone (FAZ in patients with diabetic retinopathy (DR with and without diabetic macular ischemia (DMI. Methods. The Wilcoxon signed-rank test was used to compare area measurements and p values of <0.05 were considered statistically significant. FA and OCTA images were independently graded by 2 observers that reached agreement regarding quantitative DMI according established protocols. The ischemic area was divided into “large” macular ischemia (superior to 0.32 mm2 and “small” (inferior to 0.32 mm2 groups. Quantitative analyses of the FAZ were performed using custom software. Results. Thirty-four eyes from 34 diabetic patients were enrolled. Subjects with DMI presented a mean area on FA and OCTA of 0.68 ± 0.53 mm2 and 0.58 ± 0.35 mm2, respectively (p=0.1374. Patients without DMI presented a mean area on FA and OCTA of 0.19 ± 0.67 mm2 and 0.20 ± 0.79 mm2, respectively (p=0.9594. The ICC for the FAZ measurements between the 2 observers on FA and OCTA was 0.96 and 0.92, respectively. Conclusion. OCTA represents a novel technique for the diagnosis of DMI and it may become an alternative to FA for this purpose.

  2. Optical coherence tomography angiography changes in radial peripapillary capillaries in Leber hereditary optic neuropathy

    Directory of Open Access Journals (Sweden)

    Mitsuhiro Matsuzaki

    2018-03-01

    Conclusions and importance: Optical coherence tomography angiography showed LHON from the presymptomatic stage. The results indicate that temporal RPC defects and RFT thinning start to spread once the pseudoedema begins to resolve.

  3. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block

    OpenAIRE

    Cabeda, Est?van Vieira; Falc?o, Andr?a Maria Gomes; Soares Jr., Jos?; Rochitte, Carlos Eduardo; Nomura, C?sar Higa; ?vila, Luiz Francisco Rodrigues; Parga, Jos? Rodrigues

    2015-01-01

    Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and comp...

  4. Computed tomography in subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Lee, Seung Ro; Chang, Kee Hyun; Choi, Byung Ihn; Han, Man Chung; Sim, Bo Sung

    1981-01-01

    Computed Tomography has become increasingly important diagnostic method as the initial examination in the diagnosis of subarachnoid hemorrhage with direct detection of extravasated blood in basal cistern and cortical sulci. Furthermore, CT provides better and exact visualization of the presence, localization, extent and degree of intracerebral, intraventricular and subdural hemorrhage, infarction, hydrocephalus and rebleeding which may be associated with subarachnoid hemorrhage, and also could detect the causative lesions with contrast enhancement in many cases. The purpose of the paper is to describe the CT findings of subarachnoid hemorrhage due to various causes and to evaluate the diagnostic accuracy of CT in subarachnoid hemorrhage. Authors analysed a total of 153 cases with subarachnoid hemorrhage confirmed by lumbar puncture at Seoul National University Hospital from March 1979 to April 1981, with special emphasis on CT findings. All of the cases took CT scan and 125 cases of them angiography. The results are as follows: 1. Most prevalent age group was 4th to 6th decades (78%). The ratio of male to female was 1.1: 1. 2. Of 125 cases with angiography, aneurysm was a major cause (68%). Others were arterio-venous malformation (9.6%), Moya-moya disease (4%) and unknown (18.4%). 3. Of all 153 cases with CT scan, hemorrhage was demonstrated in 98 cases (64.1%); SAH in 72 cases (47.1%), ICH in 65 cases (42.5%), IVH in 34 cases (22.2%) and SDH in 1 case (0.7%). SAH combined with ICH was a major group (34.7%) in SAH. Detection rate of SAH was 68.3% within the first 7 days and 5.8% after 7 dyas. 4. In aneurysms, SAH was detected in 60 of 85 cases (70.6%); 88.1% within the first 7 dyas and 5.6% after 7 dyas. Anterior communicating artery was the most common site of the aneurysms (40%), in which detection rate of SAH was 100% within the first 7 days. SAH was combined with ICH in 38.3%. 5. On CT, SAH of unilateral Sylvian fissure was pathognomonic for ruptured MCA

  5. Proton computed tomography

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1978-01-01

    The use of protons or other heavy charged particles instead of x rays in computed tomography (CT) is explored. The results of an experimental implementation of proton CT are presented. High quality CT reconstructions are obtained at an average dose reduction factor compared with an EMI 5005 x-ray scanner of 10:1 for a 30-cm-diameter phantom and 3.5:1 for a 20-cm diameter. The spatial resolution is limited by multiple Coulomb scattering to about 3.7 mm FWHM. Further studies are planned in which proton and x-ray images of fresh human specimens will be compared. Design considerations indicate that a clinically useful proton CT scanner is eminently feasible

  6. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  7. Optical coherence tomography angiography in age-related macular degeneration: The game changer.

    Science.gov (United States)

    Lupidi, Marco; Cerquaglia, Alessio; Chhablani, Jay; Fiore, Tito; Singh, Sumit Randhir; Cardillo Piccolino, Felice; Corbucci, Roberta; Coscas, Florence; Coscas, Gabriel; Cagini, Carlo

    2018-04-01

    Optical coherence tomography angiography is one of the biggest advances in ophthalmic imaging. It enables a depth-resolved assessment of the retinal and choroidal blood flow, far exceeding the levels of detail commonly obtained with dye angiographies. One of the first applications of optical coherence tomography angiography was in detecting the presence of choroidal neovascularization in age-related macular degeneration and establishing its position in relation to the retinal pigmented epithelium and Bruch's membrane, and thereby classifying the CNV as type 1, type 2, type 3, or mixed lesions. Optical coherence tomography angiograms, due to the longer wavelength used by optical coherence tomography, showed a more distinct choroidal neovascularization vascular pattern than fluorescein angiography, since there is less suffering from light scattering or is less obscured by overlying subretinal hemorrhages or exudation. Qualitative and quantitative assessments of optical coherence tomography angiography findings in exudative and nonexudative age-related macular degeneration have been largely investigated within the past 3 years both in clinical and experimental settings. This review constitutes an up-to-date of all the potential applications of optical coherence tomography angiography in age-related macular degeneration in order to better understand how to translate its theoretical usefulness into the current clinical practice.

  8. Computed tomography of juvenile nasopharyngeal angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yoo, Shi Joon; Lee, Yul; Chang, Kee Hyun; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma.

  9. Computer tomography of the neurocranium.

    Science.gov (United States)

    Liliequist, B; Forssell, A

    1976-07-01

    The experience with computer tomography of the neurocranium in 300 patients submitted for computer tomography of the brain is reported. The more appropriate projections which may be obtained with the second generation of scanners in combination with an elaborated reconstruction technique seem to constitute a replacement of conventional skull films.

  10. Computed tomography of cerebrovascular accidents

    International Nuclear Information System (INIS)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin

    1989-01-01

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography

  11. Computed tomography of cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Deuk; Moon, Yang In; Lim, Se Hwan; Lee, Cheorl Woo; Kim, Byung Chan; Won, Jong Jin [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1989-10-15

    Computed tomography (CT) is an accurate and noninvasive method in the evaluation of cerebrovascular accidents (CVA) for detection of nature, location, extension and associated changes. Retrospective analysis was done in 402 patients of clinically suspected CVA who were performed CT in our hospital from December 1985 to December 1987. The results were as follows; 1. The analysis of CT findings in 402 patients showed 321 cases of CVA, 79 cases of normal findings, and 2 cases of brain tumors. 2. Among 321 cases of CVA, intracerebral hemorrhage was noted in 158 cases, cerebral infarction in 126 cases, and subarachnoid hemorrhage in 37 cases. 3. The common sites of cerebral hemorrhage were basal ganglia in 99 cases, especially putamen, thalamus in 32 cases, and cerebrum, cerebellum in 11 cases respectively. Cerebral infarction was found chiefly at the areas distributed by the middle cerebral artery: cerebral lobe 55 cases and basal ganglia 51 cases. The aneurysm was the most common cause of subarachnoid hemorrhage, and its common site was posterior communicating artery and middle cerebral artery areas. 4. The common shape of cerebral infarction was oval in basal ganglia and wedged in the cerebral lobes. The contrast enhancement of the cerebral infarction was observed in 10% of cases between the 3rd days and 2nd weeks after onset, and was usually gyral patients (77.7%). 5. The aneurysm was noted as enhancing nodule on contrast CT in all 14 cases. In conclusion, the most common cause of CVA is intracerebral hemorrhage in Iri, Korea. High resolution contrast enhanced CT can be used in the diagnosis of the ruptured cerebral aneurysm without the aid of cerebral angiography.

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  13. Image Quality, Overall Evaluability, and Effective Radiation Dose of Coronary Computed Tomography Angiography With Prospective Electrocardiographic Triggering Plus Intracycle Motion Correction Algorithm in Patients With a Heart Rate Over 65 Beats Per Minute.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Baggiano, Andrea; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Fazzari, Fabio; Mushtaq, Saima; Conte, Edoardo; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Verdecchia, Massimo; Fusini, Laura; Bonfanti, Lorenzo; Consiglio, Elisa; Rabbat, Mark G; Bartorelli, Antonio L; Pepi, Mauro

    2018-01-16

    Recently, a new intracycle motion correction algorithm (MCA) was introduced to reduce motion artifacts from heart rate (HR) in coronary computed tomography angiography (cCTA). The aim of the study was to evaluate the image quality, overall evaluability, and effective radiation dose (ED) of cCTA with prospective electrocardiographic (ECG) triggering plus MCA as compared with standard protocol with retrospective ECG triggering in patients with HR≥65 bpm. One hundred consecutive patients (67±10 y) scheduled for cCTA with 65Ethics Committee and a written informed consent was obtained from all patients. Image noise, signal to noise ratio, contrast to noise ratio, Likert image quality score (score 1, nondiagnostic; score 2, adequate; score 3, good; score 4, excellent), overall image evaluability, and ED were measured and compared between the 2 groups. Both vessel-based and patient-based analyses were evaluated. Student test or Wilcoxon test were used to evaluate differences of continuous variables, whereas the χ test was used to study differences with regard to categorical data. A P-value <0.05 was considered statistically significant. cCTA was successfully performed in all patients. In a segment-based model, group 1 compared with group 2 showed a lower rate of overall artifacts (67% vs. 83%; P<0.001) and motion artifacts (49% vs. 66%; P<0.001), resulting in a better Likert image quality score (2.83±1.03 vs. 2.37±1.02; P<0.01) and overall evaluability (85% vs. 75%; P<0.01). Group 1 showed a lower ED as compared with group 2 (3.1±1.9 vs. 11.9±3.3 mSv; P<0.01). MCA and cCTA with prospective ECG-triggering acquisition in patients with high HR improves image quality and overall evaluability compared with cCTA with standard retrospective ECG triggering.

  14. CAPILLARY NETWORK ANOMALIES IN BRANCH RETINAL VEIN OCCLUSION ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    Rispoli, Marco; Savastano, Maria Cristina; Lumbroso, Bruno

    2015-11-01

    To analyze the foveal microvasculature features in eyes with branch retinal vein occlusion (BRVO) using optical coherence tomography angiography based on split spectrum amplitude decorrelation angiography technology. A total of 10 BRVO eyes (mean age 64.2 ± 8.02 range between 52 years and 76 years) were evaluated by optical coherence tomography angiography (XR-Avanti; Optovue). The macular angiography scan protocol covered a 3 mm × 3 mm area. The focus of angiography analysis were two retinal layers: superficial vascular network and deep vascular network. The following vascular morphological congestion parameters were assessed in the vein occlusion area in both the superficial and deep networks: foveal avascular zone enlargement, capillary non-perfusion occurrence, microvascular abnormalities appearance, and vascular congestion signs. Image analyses were performed by 2 masked observers and interobserver agreement of image analyses was 0.90 (κ = 0.225, P network of BRVO, a decrease in capillary density with foveal avascular zone enlargement, capillary non-perfusion occurrence, and microvascular abnormalities appearance was observed (P network showed the main vascular congestion at the boundary between healthy and nonperfused retina. Optical coherence tomography angiography in BRVO allows to detect foveal avascular zone enlargement, capillary nonperfusion, microvascular abnormalities, and vascular congestion signs both in the superficial and deep capillary network in all eyes. Optical coherence tomography angiography technology is a potential clinical tool for BRVO diagnosis and follow-up, providing stratigraphic vascular details that have not been previously observed by standard fluorescein angiography. The normal retinal vascular nets and areas of nonperfusion and congestion can be identified at various retinal levels. Optical coherence tomography angiography provides noninvasive images of the retinal capillaries and vascular networks.

  15. Computed tomography apparatus

    International Nuclear Information System (INIS)

    Fairbairn, I.A.

    1984-01-01

    In fan-beam computed tomography apparatus, timing reference pulses, normally occurring at intervals t, for data transfer and reset of approx. 500 integrators in the signal path from the detector array, are generated from the scan displacement, e.g. using a graticule and optical sensor to relate the measurement paths geometrically to the body section. Sometimes, a slow scan rate is required to provide a time-averaged density image, e.g. for planning irradiation therapy, and then the sensed impulses will occur at extended intervals and can cause integrator overload. An improvement is described which provides a pulse generator which responds to a reduced scan rate by generating a succession of further transfer and reset pulses at intervals approximately equal to t starting a time t after each timing reference pulse. Then, using an adding device and RAM, all the transferred signals integrated in the interval t' between two successive slow scan reference pulses are accumulated in order to form a corresponding measurement signal. (author)

  16. Computed tomography intravenous cholangiography

    International Nuclear Information System (INIS)

    Nascimento, S.; Murray, W.; Wilson, P.

    1997-01-01

    Indications for direct visualization of the bile ducts include bile duct dilatation demonstrated by ultrasound or computed tomography (CT) scanning, where the cause of the bile duct dilatation is uncertain or where the anatomy of bile duct obstruction needs further clarification. Another indication is right upper quadrant pain, particularly in a post-cholecystectomy patient, where choledocholithiasis is suspected. A possible new indication is pre-operative evaluation prior to laparoscopic cholecystectomy. The bile ducts are usually studied by endoscopic retrograde cholangiopancreatography (ERCP), or, less commonly, trans-hepatic cholangiography. The old technique of intravenous cholangiography has fallen into disrepute because of inconsistent bile-duct opacification. The advent of spiral CT scanning has renewed interest in intravenous cholangiography. The CT technique is very sensitive to the contrast agent in the bile ducts, and angiographic and three-dimensional reconstructions of the biliary tree can readily be obtained using the CT intravenous cholangiogram technique (CT IVC). Seven patients have been studied using this CT IVC technique, between February 1995 and June 1996, and are the subject of the present report. Eight further studies have since been performed. The results suggest that CT IVC could replace ERCP as the primary means of direct cholangiography, where pancreatic duct visualization is not required. (authors)

  17. Computed tomography of the pancreas

    International Nuclear Information System (INIS)

    Kolmannskog, F.; Kolbenstvedt, A.; Aakhus, T.; Bergan, A.; Fausa, O.; Elgjo, K.

    1980-01-01

    The findings by computed tomography in 203 cases of suspected pancreatic tumours, pancreatitis or peripancreatic abnormalities were evaluated. The appearances of the normal and the diseased pancreas are described. Computed tomography is highly accurate in detecting pancreatic masses, but can not differentiate neoplastic from inflammatory disease. The only reliable signs of pancreatic carcinoma are a focal mass in the pancreas, together with liver metastasis. When a pancreatic mass is revealed by computed tomography, CT-guided fine-needle aspiration biopsy of the pancreas is recommended. Thus the need for more invasive diagnostic procedures and explorative laparotomy may be avoided in some patients. (Auth.)

  18. Computed tomography of the head in neurological examination of children

    International Nuclear Information System (INIS)

    Baeckman, E.; Egg-Olofsson, O.; Raadberg, C.

    1980-01-01

    A total of 247 children from the departments of pediatrics and neurosurgery were examined with computed tomography of the head during a two year period in 1977-78. Pathological changes were demonstrated in 79 per cent. Supplementary neuro-radiological examination - angiography and encephalography - was necessary in 17 per cent. Computed tomography together with the clinical assessment frequently suffices for final diagnosis. Computed tomography greatly reduces the need for previously used neurological examinations including skull radiography. Complications may ensure because of over-sensitivity to intravenously administered contrast medium in connection with anesthesia, and the radiation dose particularly to the crystalline lens of the eye must be taken into account. Computed tomography should therefore be used only on strict indications after careful scrutiny of the case history and the status. (author)

  19. Exposed dose comparison between coronary computed tomographic angiography and coronary angiography. Basic examination by phantom

    International Nuclear Information System (INIS)

    Kato, Kyoichi; Takahashi, Yoshimasa; Takahashi, Toshiyuki; Sai, Syogo; Fujimura, Kazumasa; Watanabe, Hiroyuki; Sato, Hisaya; Imai, Yasuhiro; Nakazawa, Yasuo

    2007-01-01

    The new type of coronary angiography (CAG) that uses 40 mm volumetric computed tomography (VCT) has great potential for cardiac disease. However, it is still necessary to be cognizant of exposure dose. We measured doses of CAG by both VCT and cardiovascular X-ray using a body phantom within 170 glass dosimeters. VCT protocols were 120 kV, 570 mA, and 0.35 sec/rot with and without the dose-reduction features (small cardiac X-ray beam filter and electrocardiogram (ECG) mA modulation). The cardiovascular X-ray protocol was Auto (65-77 kV) kV, Auto (41-46 mA) mA, 5 sec x 11 shots + 11 min fluoroscopy (minimum protocol for screening). VCT with and without the dose-reduction features has the same dose distribution, however, the dose-reduction features reduced the amount of dose by about 40-50%. For VCT with those features, measured dose was about 70 mGy in the cardiac area and 60 mGy at the skin of the back, whereas those of cardiovascular X-ray were 10 mGy and 30 mGy. We measured detailed dose distributions and variations in the phantom, and we also demonstrated the possibility of VCT's dose-reduction features. The CT dose was still higher than that of cardiovascular X-ray, however, there were advantages of CT scanning, for instance, information about calcification, soft plaque, and three-dimensional (3D) visualization. We think it is important to use both systems with an understanding of their advantages and limitations. (author)

  20. Estimation of intrathoracic arterial diameter by means of computed tomographic angiography in Hispaniolan Amazon parrots.

    Science.gov (United States)

    Beaufrère, Hugues; Rodriguez, Daniel; Pariaut, Romain; Gaschen Dvm, Lorrie; Schnellbacher, Rodney; Nevarez, Javier G; Tully, Thomas N

    2011-02-01

    To establish a computed tomography (CT)-angiography protocol and measure the diameters of major arteries in parrots. 13 Hispaniolan Amazon parrots (Amazona ventralis). 16-slice CT scanning was used to measure the apparent diameter of the ascending aorta, abdominal aorta, pulmonary arteries, and brachiocephalic trunk. Before scanning, all birds underwent ECG and echocardiographic assessment and were considered free of detectable cardiovascular diseases. Each bird was anesthetized, and a precontrast helical CT scan was performed. Peak aortic enhancement was established with a test bolus technique via dynamic axial CT scan over a predetermined single slice. An additional bolus of contrast medium was then injected, and a helical CT-angiography scan was performed immediately afterward. Arterial diameter measurements were obtained by 2 observers via various windows before and after injection, and intra- and interobserver agreement was assessed. Reference limits were determined for arterial diameter measurements before and after contrast medium administration in pulmonary, mediastinal, and manual angiography windows. Ratios of vertebral body diameter to keel length were also calculated. Intraobserver agreement was high (concordance correlation coefficients ≥ 0.95); interobserver agreement was medium to high (intraclass correlation coefficients ≥ 0.65). CT-angiography was safe and is of potential diagnostic value in parrots. We recommend performing the angiography immediately after IV injection of 3 mL of iohexol/kg. Arterial diameter measurements at the described locations were reliable.

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  2. Computed tomography of drill cores

    International Nuclear Information System (INIS)

    Taylor, T.

    1985-08-01

    A preliminary computed tomography evaluation of drill cores of granite and sandstone has generated geologically significant data. Density variations as small as 4 percent and fractures as narrow as 0.1 mm were easily detected

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Children's (Pediatric) CT (Computed Tomography) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  8. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  9. Assessment of extracranial-intracranial bypass patency with 64-slice multidetector computerized tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Thines, Laurent [Lille University Hospital, Department of Neurosurgery, Lille (France); Toronto Western Hospital, Division of Neurosurgery and Department of Surgery, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada); Agid, Ronit; Da Costa, Leodante; Terbrugge, Karel G. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada); Dehdashti, Amir R.; Wallace, M.C.; Tymianski, Michael [Toronto Western Hospital, Division of Neurosurgery and Department of Surgery, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada)

    2009-08-15

    Extracranial-intracranial (EC/IC) bypass is a useful procedure for the treatment of cerebral vascular insufficiency or complex aneurysms. We explored the role of multidetector computed tomography angiography (MDCTA), instead of digital subtraction angiography (DSA), for the postoperative assessment of EC/IC bypass patency. We retrospectively analyzed a consecutive series of 21 MDCTAs from 17 patients that underwent 25 direct or indirect EC/IC bypass procedures between April 2003 and November 2007. Conventional DSA was available for comparison in 13 cases. MDCTA used a 64-slice MDCT scanner (Aquilion 64, Toshiba). The proximal and distal patencies were analyzed independently on MDCTA and DSA by a neuroradiologist and a neurosurgeon. The bypass was considered patent when the entire donor vessel was opacified without discontinuity from proximal to distal ends and was visibly in contact with the recipient vessel. MDCTA depicted the patency status in every patient. Bypasses were patent in 22 cases, stenosed in one, and occluded in two. DSA always confirmed the results of the MDCTA (sensitivity = 100%, 95% CI = 0.655-1.0; specificity 100%, 95% CI = 0.05-1.0). MDCTA is a non-invasive and accurate exam to assess the postoperative EC/IC bypass patency and is a promising technique in routine follow-up. (orig.)

  10. [Effects of anteriolateral thigh perforator flap and fascia lata transplantation in combination with computed tomography angiography on repair of electrical burn wounds of head with skull exposure and necrosis].

    Science.gov (United States)

    Li, X Q; Wang, X; Han, Y L; Ji, G; Chen, Z H; Zhang, J; Zhu, J P; Duan, J X; He, Y J; Yang, X M; Liu, W J

    2018-05-20

    Objective: To explore the effects of anteriolateral thigh perforator flap and fascia lata transplantation in combination with computed tomography angiography (CTA) on repair of electrical burn wounds of head with skull exposure and necrosis. Methods: Seven patients with head electrical burns accompanied by skull exposure and necrosis were admitted to our burn center from March 2016 to December 2017. Head CTA was performed before the operation. The diameters of the facial artery and vein or the superficial temporal artery and vein were measured, and their locations were marked on the body surface. Preoperative CTA for flap donor sites in lower extremities were also performed to track the descending branch of the lateral circumflex femoral artery with the similar diameter as the recipient vessels on the head, and their locations were marked on the body surface. Routine wound debridement and skull drilling were performed successively. The size of the wounds after debridement ranged from 12 cm×8 cm to 20 cm×12 cm, and the areas of skull exposure ranged from 8 cm×6 cm to 15 cm×10 cm. Anteriolateral thigh perforator flaps with areas from 13 cm×9 cm to 21 cm×13 cm containing 5-10 cm long vascular pedicles were designed and dissected accordingly. The fascia lata under the flap with area from 5 cm×2 cm to 10 cm×3 cm was dissected according to the length of vascular pedicle. The fascia lata was transplanted to cover the exposed skull, and the anteriolateral thigh perforator flap was transplanted afterwards. The descending branch of the lateral circumflex femoral artery and its accompanying vein of the flap were anastomosed with superficial temporal artery and vein or facial artery and vein before the suture of flap. The flap donor sites were covered by intermediate split-thickness skin graft collected from contralateral thigh or abdomen. Results: The descending branch of the lateral circumflex femoral artery and its accompanying vein were anastomosed with superficial

  11. Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors

    Science.gov (United States)

    Skalet, Alison H.; Li, Yan; Lu, Chen D.; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G.; Thomas, Charles R.; Huang, David

    2016-01-01

    Objective To evaluate tumor vasculature with optical coherence tomography (OCT) angiography (OCTA) in malignant iris melanomas and benign iris lesions. Design Cross-sectional observational clinical study. Participants Patients with iris lesions and healthy volunteers. Methods Eyes were imaged using OCTA systems operating at 1050 and 840 nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanomas patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. Main Outcome Measures OCT and OCTA images, qualitative evaluation of iris and tumor vasculature and quantitative vessel density. Results One eye each of eight normal volunteers and nine patients with iris melanomas or benign iris lesions including freckles, nevi, and an iris pigment epithelial (IPE) cyst were imaged. The normal iris has radially-oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In two eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, piris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050 nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% participants in whom imaging was attempted. Conclusions This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no

  12. Computed tomography of the traumatized abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki [Wallace Memotial Baptist Hospital, Pusan (Korea, Republic of)

    1989-02-15

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries.

  13. Computed tomography of the traumatized abdomen

    International Nuclear Information System (INIS)

    Yoon, Young Woon; Baik, Seung Kug; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki

    1989-01-01

    Forty-seven patients with abdominal and retroperitoneal injuries were examined by computed tomography(CT). We analyzed the results of 47 patients who were confirmed of abdominal injuries by operation, clinical follow up, and repeated radiologic examinations. 1. the type of trauma was blunt in 38 patients (81%) and penerating in 9 patients (19%) 2. There were 14 splenic, 11 renal, 9 hepatic, 6 retroperitoneal, 4 pancreatic, and 3 alimentary tract injuries. 3. The patients who had been treated by conservative management were 23.4% (surgical treatment,76.6%). 4. The six ratio was 4.9 : 1.0 (male ; female). 5. CT has major advantage over plain radiography, radionuclide imaging, and angiography in assessment of trauma-induced injuries

  14. Diltiazem como alternativa ao betabloqueador na angiotomografia de artérias coronárias Diltiazem as an alternative to beta-blocker in coronary artery computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Rochitte

    2012-08-01

    reduction of HR and RR variability of metoprolol and diltiazem in CTACor. METHODS: Prospective, randomized, open study that included patients with clinical indication of CTACor in sinus rhythm with HR > 70 bpm and no use of agents that could interfere with HR. Fifty patients were randomized to the groups: metoprolol IV 5-15 mg or up to HR ≤ 60 bpm (M, and diltiazem IV 0.25 to 0.60 mg/kg or up to HR ≤ 60 bpm (D. Blood pressure (BP and HR were measured at baseline, 1 minute, 3 minutes and 5 minutes after the agents, at the acquisition and after CTACor. RESULTS: HR reduction in absolute values was higher in group M than in group D (1, 3, 5 min, acquisition and post-test. The percentage reduction of HR was significantly higher in group M only 1 min and 3 min after the start of the agents. There was no difference in 5 min at acquisition and after examination. The percentage RR variability in group D was lower than that in group M during acquisition (RR variability/mean HR of acquisition. A single case of AVB, 2:1 Mobitz I occurred, which was spontaneously reverted (group D. CONCLUSION: We conclude that diltiazem is an effective and safe alternative to beta-blockers in the reduction of HR when performing computed tomography angiography of coronary arteries. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0

  15. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  16. Neuroanatomy of cranial computed tomography

    International Nuclear Information System (INIS)

    Kretschmann, H.J.; Weinrich, W.

    1985-01-01

    Based on the fundamental structures visualized by means of computed tomography, the authors present the functional systems which are relevant in neurology by means of axial cross-sections. All drawings were prepared from original preparations by means of a new technique which is similar to the grey values of X-ray CT and nuclear magnetic resonance tomography. A detailed description is given of the topics of neurofunctional lesions

  17. Vertebrobasilar system computed tomographic angiography in central vertigo.

    Science.gov (United States)

    Paşaoğlu, Lale

    2017-03-01

    The incidence of vertigo in the population is 20% to 30% and one-fourth of the cases are related to central causes. The aim of this study was to evaluate computed tomography angiography (CTA) findings of the vertebrobasilar system in central vertigo without stroke.CTA and magnetic resonance images of patients with vertigo were retrospectively evaluated. One hundred twenty-nine patients suspected of having central vertigo according to history, physical examination, and otological and neurological tests without signs of infarction on diffusion-weighted magnetic resonance imaging were included in the study. The control group included 120 patients with similar vascular disease risk factors but without vertigo. Vertebral and basilar artery diameters, hypoplasias, exit-site variations of vertebral artery, vertebrobasilar tortuosity, and stenosis of ≥50% detected on CTA were recorded for all patients. Independent-samples t test was used in variables with normal distribution, and Mann-Whitney U test in non-normal distribution. The difference of categorical variable distribution according to groups was analyzed with χ and/or Fisher exact test.Vertebral artery hypoplasia and ≥50% stenosis were seen more often in the vertigo group (P = 0.000, vertigo patients had ≥50% stenosis, 54 (69.2%) had stenosis at V1 segment, 9 (11.5%) at V2 segment, 2 (2.5%) at V3 segment, and 13 (16.6%) at V4 segment. Both vertigo and control groups had similar basilar artery hypoplasia and ≥50% stenosis rates (P = 0.800, >0.05).CTA may be helpful to clarify the association between abnormal CTA findings of vertebral arteries and central vertigo.This article reveals the opportunity to diagnose posterior circulation abnormalities causing central vertigo with a feasible method such as CTA.