WorldWideScience

Sample records for computadorizada helicoidal sem

  1. Tomografia computadorizada sem contraste intravenoso no abdome agudo: quando e por que usar When and why use unenhanced computed tomography in patients with acute abdomen

    Directory of Open Access Journals (Sweden)

    Edison de Oliveira Freire Filho

    2006-02-01

    Full Text Available A tomografia computadorizada sem contraste intravenoso tem sido freqüentemente proposta na avaliação inicial de pacientes com suspeita de abdome agudo, ocupando o espaço de outros métodos diagnósticos. Os autores apresentam uma revisão bibliográfica dos principais aspectos e eficácia da tomografia computadorizada sem contraste intravenoso no diagnóstico de apendicite aguda, cólica nefrética, diverticulite, pancreatite aguda, apendicite epiplóica, pneumoperitônio e obstrução intestinal. Discutem quais as vantagens e limitações desta técnica de exame, bem como seus aspectos práticos.The use of unenhanced computed tomography has been frequently recommended for the initial assessment of patients with clinical suspicion of acute abdomen instead of other diagnostic methods. The authors present a review of the literature on the main aspects, advantages, limitations and efficacy of unenhanced computed tomography for the diagnosis of acute appendicitis, renal colic, diverticulitis, acute pancreatitis, primary epiploic appendicitis, pneumoperitoneum and small bowel obstruction. The advantages and limitations of this technique are also discussed.

  2. Avaliação da concordância interobservador na análise da tomografia computadorizada sem contraste no diagnóstico da urolitíase em pacientes com cólica renal aguda Interobserver agreement on non-contrast computed tomography interpretation for diagnosis of urolithiasis in patients with acute flank pain

    Directory of Open Access Journals (Sweden)

    Luís Ronan Marquez Ferreira de Souza

    2006-10-01

    Full Text Available OBJETIVO: Avaliar a reprodutibilidade da tomografia computadorizada sem contraste na avaliação da litíase ureteral e os sinais secundários de obstrução do sistema coletor em pacientes com cólica renal aguda. MATERIAIS E MÉTODOS: Estudo prospectivo de 52 pacientes com diagnóstico clínico de cólica renal aguda submetidos a exame de tomografia computadorizada de abdome sem contraste. Os exames foram realizados com técnica helicoidal e posteriormente analisados por três observadores independentes, com a concordância interobservador avaliada pelo método estatístico kappa (kapa. Foram analisados os parâmetros: a presença, localização e mensuração dos cálculos ureterais; b dilatação do sistema coletor intra-renal; c heterogeneidade da gordura perirrenal; d dilatação ureteral; e edema da parede ureteral (sinal do halo. RESULTADOS: Foram encontrados 40 cálculos ureterais na tomografia computadorizada (77%. A concordância interobservador para a identificação do cálculo ureteral e da dilatação ureteral foi quase perfeita (kapa = 0,89 e kapa = 0,87, respectivamente, substancial para dilatação do sistema coletor intra-renal (kapa = 0,77 e moderada para heterogeneidade da gordura perirrenal e para edema da parede ureteral (kapa = 0,55 e kapa = 0,56, respectivamente. CONCLUSÃO: A tomografia computadorizada de abdome sem contraste apresenta elevada reprodutibilidade na avaliação da litíase ureteral e dos sinais secundários de obstrução do sistema coletor.OBJECTIVE: To evaluate the interobserver agreement on non-contrast computed tomography interpretation by a group of experienced abdominal radiologists, for the study of urolithiasis in patients presenting acute flank pain. MATERIALS AND METHODS: Prospective study of 52 patients submitted to non-contrast enhanced helical computed tomography. The images were subsequently analyzed by three independent observers, with the interobserver agreement assessed by means of the

  3. O valor da fase sem contraste na tomografia computadorizada do abdome The role of the unenhanced phase in the routine abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Ana Paula Klautau Leite

    2008-10-01

    Full Text Available OBJETIVO: Determinar o valor agregado da fase sem meio de contraste da tomografia computadorizada do abdome em pacientes sem diagnóstico determinado ou em estadiamento tumoral. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 100 pacientes consecutivos submetidos a tomografia computadorizada abdominal sem e com meio de contraste intravenoso. Dois examinadores avaliaram todos os exames, procurando estabelecer, através da fase com meio de contraste intravenoso (primeira análise e posteriormente através da fase sem contraste (segunda análise, o diagnóstico principal e os secundários em função da indicação clínica do exame. Mediu-se a freqüência de mudança diagnóstica decorrente da análise combinada das fases pré- e pós-contraste intravenoso. Casos que tiveram mudança diagnóstica foram avaliados por especialistas clínicos para determinar se implicaria mudanças de conduta. RESULTADOS: Diagnósticos principal e secundário foram modificados em 1 e 18 casos, respectivamente (p = 1,000; p = 0,143. Os diagnósticos modificados foram: esteatose, definição de nódulo em adrenal, nefrolitíase, classificação de cistos renais e calcificação hepática. Nos casos em que a fase sem contraste modificou o diagnóstico, os especialistas mudaram sua conduta em 14/19 (73% dos pacientes (p = 0,038. CONCLUSÃO: A fase sem contraste não modificou significativamente o diagnóstico principal ou secundário. Porém, as mudanças nos diagnósticos secundários influenciaram na conduta adotada pelos especialistas.OBJECTIVE: To determine the role of the unenhanced phase of abdominal computed tomography in patients without a definite diagnosis or undergoing tumor staging. MATERIALS AND METHODS: A prospective and transversal study was developed with 100 consecutive patients submitted to unenhanced and contrast-enhanced abdominal computed tomography. Two observers evaluated all the computed tomography images in the contrast-enhanced phase

  4. Reflection of neutrons from a helicoidal system

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Ignatovich, V.K.; Nikitenko, Yu.V.

    2006-01-01

    Analytical solution for neutron reflection and transmission of magnetic mirrors with helicoidal magnetization is found. The dependence of neutron speed of reflection and transmission curves is shown. Resonant properties of helicoidal systems are found

  5. Estudo descritivo da resposta de acuidade visual sem correção e pressão intra-ocular computadorizada de não contato em jogadores de futebol amadores e profissionais

    Directory of Open Access Journals (Sweden)

    Emídio Valenti Tavares

    1999-08-01

    Full Text Available O principal objetivo deste estudo foi verificar as possíveis alterações de acuidade visual e pressão intra-ocular em jogadores de futebol. A clínica Oftalmos e Cirurgia Oftalmológica submeteu à avaliação oftalmológica 127 atletas futebolistas provenientes de várias categorias, incluindo mulheres, com idades variando de 14 a 33 anos. Todos foram submetidos a testes de acuidade visual sem correção, utilizando-se a tabela de Snellen e avaliando-se a pressão intra-ocular de não contato com um tonômetro computadorizado (modelo TX-10, Canon, EUA. Além disso, os atletas foram submetidos a exame de auto-refração, no equipamento auto-refrator (modelo R-30, Canon, EUA. Os seguintes parâmetros utilizados e os resultados encontrados foram: dos 127 atletas avaliados, 56 (44% apresentaram alterações de auto-refração, consideradas de grau mais ou menos importante em um ou ambos os olhos. No teste de acuidade visual, 3% e 2,4% dos atletas apresentaram, no OD e OE, somente 20/100 e 20/200 pés de visão, respectivamente. Em uma jogadora, foi constatada catarata puntata congênita. Os resultados da tonometria mostraram, em 5 atletas de cor negra, quadro suspeito de glaucoma (necessitando investigação mais apurada.Concluindo, o estudo comprovou a importância da oftalmologia como medida preventiva e/ou corretiva na identificação de possíveis alterações oftalmológicas em atletas futebolistas, devendo ser uma prática rotineira nesse esporte.

  6. A bioinspired study on the compressive resistance of helicoidal fibre structures.

    Science.gov (United States)

    Tan, Ting; Ribbans, Brian

    2017-10-01

    Helicoidal fibre structures are widely observed in natural materials. In this paper, an integrated experimental and analytical approach was used to investigate the compressive resistance of helicoidal fibre structures. First, helicoidal fibre-reinforced composites were created using three-dimensionally printed helicoids and polymeric matrices, including plain, ring-reinforced and helix-reinforced helicoids. Then, load-displacement curves under monotonic compression tests were collected to measure the compressive strengths of helicoidal fibre composites. Fractographic characterization was performed using an X-ray microtomographer and scanning electron microscope, through which crack propagations in helicoidal structures were illustrated. Finally, mathematical modelling was performed to reveal the essential fibre architectures in the compressive resistance of helicoidal fibre structures. This work reveals that fibre-matrix ratios, helix pitch angles and interlayer rotary angles are critical to the compressive resistance of helicoidal structures.

  7. Helicoidal microstructure of Scarabaei cuticle and biomimetic research

    International Nuclear Information System (INIS)

    Chen, B.; Peng, X.; Cai, C.; Niu, H.; Wu, X.

    2006-01-01

    Insect cuticles as a natural biocomposite include many favorable microstructures which have been refined over centuries and endow the cuticles excellent mechanical and physical properties, such as light weight, high strength and toughness, etc. The various microstructures of a Scarabaei cuticle are investigated with a scanning electronic microscope and reported in this paper. It is found that the cuticle is a kind of fiber-reinforced biocomposite composed of chitin-fiber layers and sclerous protein matrixes. Different chitin-fiber layers have different orientations, composed of crossed and helicoidal structures at different location. In the helicoidal structure, each fiber layer rotates with an almost fixed angle against its neighboring layer. The maximum pullout energy of the helicoidal structure is analyzed based on the representative model of the structure. The result shows that the pullout energy of the helicoidal structure is markedly larger than that of the conventional 0 o -structure. A biomimetic composite with the observed helicoidal structure is designed and fabricated. A comparative test shows that the fracture toughness of the biomimetic composite is markedly larger than that of the 0 o -layer composite

  8. METHODS FOR THE REPRESENTATION OF THE HELICOIDAL SURFACE

    Directory of Open Access Journals (Sweden)

    SCURTU Liviu-Iacob

    2017-05-01

    Full Text Available In this paper there are presented the graphical methods to determine the parameters of an helicoidal stairs. The first part of this paper shows the used methods to generate the helicoidal curves using descriptive geometry methods. It has represented the state of the art of the generation of a helical surface studies. The second part of this study shows the helical stairs surface representation using descriptive geometry methods. For the representation of the helicoidal stairs are used two projections, the front and top view. A method of the stairs representation is solved using CAD modelling dedicated software. Following the helical surface representation in both methods, has been achieved a comparative study by using two representation methods. Conclusions about these two representation methods are presented in the end of this paper.

  9. Helicoid peripapillary chorioretinal degeneration complicated by choroidal neovascularization.

    Science.gov (United States)

    Triantafylla, Magdalini; Panos, Georgios D; Dardabounis, Doukas; Nanos, Panagiotis; Konstantinidis, Aristeidis

    2016-02-15

    Helicoid peripapillary chorioretinal degeneration (HPCD) is a hereditary disease of the fundus that is characterized by atrophic chorioretinal areas that appear early in life and expand gradually from the optic disc towards the macula and the periphery. We describe the case of an elderly man with a known diagnosis of HPCD who developed choroidal neovascular membrane (CNV) in both eyes during the course of the disease. The patient was treated with intravitreal injection of ranibizumab, to which he had excellent response. The CNV subsided with 2 injections in the right eye and 1 in the left. Two years after the initial diagnosis of CNV in the right eye, visual acuity was 5/10 OD and 9/10 OS. Helicoid peripapillary chorioretinal degeneration is rarely complicated by CNV as the fundus lacks the trigger factors that would sustain this process. Although rare, HPCD complicated by CNV can be seen bilaterally, but responds well to few ranibizumab injections.

  10. Tomografia computadorizada das patologias acometendo o compartimento iliopsoas

    Directory of Open Access Journals (Sweden)

    Montandon Cristiano

    2001-01-01

    Full Text Available Este trabalho tem como objetivo revisar as patologias que acometem o compartimento iliopsoas. Foi realizada análise retrospectiva de casos com acometimento do compartimento iliopsoas avaliados por tomografia computadorizada (TC, no Departamento de Radiologia da Faculdade de Ciências Médicas da Universidade Estadual de Campinas, nos últimos dez anos, confirmados por biópsia cirúrgica ou percutânea. Os principais diagnósticos encontrados foram neoplasias, abscessos e hematomas. Os achados tomográficos baseiam-se na extensão do acometimento iliopsoas, no grau de atenuação, margens da lesão, presença de gás e/ou calcificações, destruição óssea, infiltração da gordura e acometimento de estruturas abdominais adjacentes. A TC é o método de escolha na avaliação do compartimento iliopsoas, podendo ser utilizada para orientar biópsias percutâneas, cirúrgicas ou drenagem. Porém, os achados isolados do estudo por TC, sem o conhecimento da história clínica, não são específicos para permitir a diferenciação das diversas patologias que acometem o compartimento iliopsoas.

  11. Avaliação da reprodutibilidade da tomografia computadorizada no estadiamento da pancreatite aguda Reproducibility in the assessment of acute pancreatitis with computed tomography

    Directory of Open Access Journals (Sweden)

    Edison de Oliveira Freire Filho

    2007-12-01

    Full Text Available OBJETIVO: Medir a reprodutibilidade da tomografia computadorizada sem e com contraste na avaliação da gravidade da pancreatite aguda. MATERIAIS E MÉTODOS: Cinqüenta e um exames de tomografia computadorizada abdominal sem e com contraste de pacientes com pancreatite aguda foram analisados por dois radiologistas (observadores 1 e 2. Calculamos o índice morfológico pela tomografia computadorizada sem e com contraste, separadamente, e o índice de gravidade da tomografia computadorizada para pancreatite aguda. Medimos a reprodutibilidade intra- e interobservador da tomografia computadorizada através do índice kappa (kapa. RESULTADOS: Para a concordância interobservador obtivemos kapa de 0,666, 0,705, 0,648, 0,547 e 0,631 para índice morfológico sem e com contraste, presença de necrose pancreática, extensão da necrose pancreática e índice de gravidade da tomografia computadorizada, respectivamente. Para a concordância intra-observador dos observadores 1 e 2 obtivemos, respectivamente, kapa de 0,796 e 0,732 para o índice morfológico sem contraste; 0,725 e 0,802 para o índice morfológico com contraste; 0,674 e 0,849 para a presença de necrose pancreática; 0,606 e 0,770 para a extensão da necrose pancreática; e 0,801 e 0,687 para o índice de gravidade da tomografia computadorizada. CONCLUSÃO: O estadiamento da pancreatite aguda pela tomografia computadorizada por meio do índice morfológico e do índice de gravidade da tomografia computadorizada é um método bastante reprodutível. O não-uso do contraste não afeta a reprodutibilidade da tomografia computadorizada para o cálculo do índice morfológico.OBJECTIVE: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. MATERIALS AND METHODS: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two

  12. SEM Anthology

    Science.gov (United States)

    Rodgers, Michelle; Zimar, Heather

    2004-01-01

    The "SEM Anthology" is a compilation of articles by more than 30 enrollment management professionals from a variety of institutions across the country. This collection, which has appeared in SEM Monthly over the past year, chronicles Strategic Enrollment Management efforts at campuses nationwide. The book illustrates the successes and challenges…

  13. Criptococose pulmonar: aspectos na tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Silva Ana Carina Gamboa da

    2003-01-01

    Full Text Available A criptococose pulmonar é uma doença causada pelo Criptococcus neoformans, um fungo unimórfico que possui distribuição mundial, existindo na mesma forma tanto no seu habitat natural quanto em animais e humanos. A doença possui apresentações clínica e patológica variáveis e pode manifestar-se tanto em pacientes com a imunidade normal como em imunocomprometidos, que representam a maioria dos casos. Neste trabalho são analisados os aspectos encontrados nas tomografias computadorizadas do tórax de 14 pacientes com criptococose pulmonar confirmada. Os achados mais freqüentes na tomografia do tórax foram as massas e os nódulos pulmonares. Outros aspectos observados foram as áreas de escavação, as consolidações, o espessamento do interstício peribroncovascular e o reticulado difuso. Massa pulmonar foi o achado isolado mais comum (64,2%, seguido dos nódulos isolados ou múltiplos (35,7%. Doença pulmonar difusa foi vista em apenas 14,2% dos casos. Os lobos superiores foram os mais comprometidos, sendo a doença mais comum nas regiões anteriores. A tomografia do tórax permitiu avaliar com precisão o grau de comprometimento do parênquima pulmonar.

  14. First report of root rot caused by Phytopythium helicoides on pistachio rootstock in California

    Science.gov (United States)

    We examined pathogenicity of Phytopythium helicoides on UCB-1 rootstock to investigate its role in root disease and collapse observed on potted pistachio plants. Approximately 25 potted 2-year-old pistachio rootstock trees in a Kern County, CA, research plot maintained outdoors and irrigated to cont...

  15. Eletrocardiografia computadorizada em cães: estudo comparativo

    Directory of Open Access Journals (Sweden)

    Lídia S. Oliveira

    2013-07-01

    Full Text Available O método de eletrocardiografia computadorizada (ECG-C vem sendo crescentemente difundido na medicina veterinária, havendo atualmente diversas marcas e modelos de eletrocardiógrafos disponíveis no mercado. Diante da possibilidade de diferenças na sensibilidade e na reprodutibilidade das medidas obtidas nos traçados, o presente estudo teve como objetivo comparar os parâmetros eletrocardiográficos de cães, obtidos por dois sistemas. Foram avaliados dois diferentes softwares computadorizados, o Wincardio Micromed® (WIN e o modelo TEB ECGPC® (TEB. Quarenta e dois cães hígidos, de diferentes raças (Cocker Spaniel, Daschund, Labrador, Pinscher, Pit Bull Terrier Poodle, Schnauzer, Shit Tzu, Yorkshire e sem raça definida, machos e fêmeas e com idade entre 4 meses e 16 anos foram agrupados segundo o peso e examinados pelos dois sistemas. As medidas eletrocardiográficas dos diferentes traçados foram analisadas na derivação DII. Os resultados indicaram que o sistema TEB apresentou maior sensibilidade na obtenção das medidas de duração da onda P e do complexo QRS, enquanto o sistema WIN foi mais sensível para determinar as medidas de amplitude dos mesmos parâmetros. Os animais de maior porte (26-37kg apresentaram maior variância nas medidas de duração e amplitude de onda P e duração do complexo QRS em comparação aos cães de médio (14-25kg e pequeno (1-13kg porte. O achado de diferenças entre os sistemas testados deve ser levado em consideração ao se empregar os diversos equipamentos para diagnóstico por meio de ECG-C na rotina clínica, de modo a evitarem-se divergências na interpretação dos exames entre diferentes prestadores de serviços veterinários.

  16. Evaluation by computerized morphometry of histopathological alterations of the colon wall in segments with and without intestinal transit in rats Avaliação por morfometria computadorizada das alterações histopatológicas da parede cólica em segmentos com e sem trânsito intestinal em ratos

    Directory of Open Access Journals (Sweden)

    Marcos Vieira de Sousa

    2008-10-01

    ópria, presença de células caliciformes, infiltrado inflamatório, graduação inflamatória e o tempo de exclusão de trânsito. CONCLUSÕES: Alterações histológicas ocorrem em todas as camadas da parede cólica, em segmentos sem trânsito intestinal. Ulcerações na mucosa intestinal, aumento no número de células caliciformes, maior congestão vascular na camada submucosa e reação inflamatória estavam relacionadas com o progredir do tempo de exclusão intestinal.

  17. Tomografia computadorizada no diagnóstico da otosclerose fenestral

    Directory of Open Access Journals (Sweden)

    Vicente Andy de Oliveira

    2004-01-01

    Full Text Available OBJETIVO: Identificar os principais achados tomográficos da otosclerose fenestral e avaliar a utilidade da tomografia computadorizada de alta resolução (TCAR, como método diagnóstico dessa osteodistrofia. FORMA DE ESTUDO: Estudo prospectivo multicêntrico com tomografia computadorizada (TC de ossos temporais. MATERIAL E MÉTODO: 54 pacientes com diagnóstico clínico e cirúrgico de otosclerose. Foi realizada uma análise tomográfica, em que foi avaliada a sensibilidade da TC no diagnóstico radiológico da otosclerose fenestral, sendo verificados os principais sítios de lesões dessa doença, como também a sua bilateralidade e simetria. Foram incluídos neste estudo 22 pacientes submetidos à TC de ossos temporais para investigação de outras afecções otológicas, que constituíram o grupo controle. RESULTADOS: A TC foi positiva em 87% dos pacientes (77% das orelhas. Os achados tomográficos foram bilaterais na maioria dos casos (78,7%, e o foco fenestral mais prevalente foi o foco anterior à janela oval (FAJO. CONCLUSÕES: A TC apresentou um alto índice de positividade e o FAJO foi o foco mais prevalente nessa população, podendo ser considerado um achado tomográfico altamente sugestivo de otosclerose.

  18. Experimental analysis of the velocity field in an anular channel with helicoidal wire

    International Nuclear Information System (INIS)

    Lemos, M.J.S. de.

    1979-06-01

    In general, nuclear reactor fuel elements are rod bundles with coolant flowing axially among them. LMFBR's (Liquid Metal Fast Breeder Reactor) have wire wrapped fuel rods, with the wire working as spacer and mixer. The present work consists in the experimental analysis of the velocity field created by a typical LMFBR fuel rod placed in a cylinder, yielding an annular channel with helicoidal wire. Using hot wire anemometry, the main and secondary velocity fields were measured. The range for Re was from 2.2x 10 4 to 6.1x 10 4 , for air. The aspect ratio, P/D, and the lead-to-diameter ratio, 1/D, were 1.2 and 15, respectively. (Author) [pt

  19. Continuous transesterification of biodiesel in a helicoidal reactor using recycled oil

    International Nuclear Information System (INIS)

    Avellaneda, Fredy; Salvado, Joan

    2011-01-01

    The main problem with biodiesel is the high cost of oils made from oleaginous crops. For this reason, various raw materials have been analysed with a view to reducing production costs and obtaining a product that can compete with the price of petrodiesel. Recycled oil is one of the most promising alternatives in the production of biodiesel because not only is the cheapest raw material but it also avoids the expense of treating the oil as a residue. Another way to reduce costs is to make the process more economical. Conventional technology uses sodium hydroxide as the basic catalyst and large-scale batch reactors, whose mechanical agitation requires high energy consumption due to residence times of at least 60 min and temperatures of 60 C. In this paper we use a recycled pretreated oil to compare conventional transesterification with continuous transesterification in a tubular reactor. In this reactor the reactants (oil, methanol and sodium hydroxide) flow through a helicoidal tube submerged in a heating bath at 60 C. The reactor has five outlets distributed non-uniformly to enable samples to be taken at different reaction times. This is to reduce the reaction time and avoid the need for mechanical agitation. With the aim of improving the quality of the biodiesel obtained, we varied the helicoidal system by incorporating a static micromixer and supplying energy in the form of ultrasound from the heating bath. This reactor produced biodiesel and glycerine at compositions roughly equal to those obtained in the batch process (89% FAME content at 75 min) but did so continuously (2.5 mL/min) and just 13 min after the reactants were integrated in a single line using a T device. Both the oil and the biodiesel were characterized and analysed in accordance with European standard UNE EN14214 for biodiesel. (author)

  20. Ao leitor sem medo

    Directory of Open Access Journals (Sweden)

    José Eisenberg

    2000-05-01

    Full Text Available O texto resenha Ao leitor sem medo, de Renato Janine Ribeiro (Belo Horizonte, UFMG, 1999.This text is a review of Ao leitor sem medo by Renato Janine Ribeiro (Belo Horizonte, UFMG, 1999

  1. Detecção de fraturas radiculares em imagens de tomografia computadorizada de feixe cônico utilizando diferentes parâmetros de exposição e materiais intracanais

    OpenAIRE

    Pinto, Martina Gerlane de Oliveira

    2015-01-01

    O objetivo deste estudo foi avaliar a detecção de fraturas radiculares (FRs) em imagens de Tomografia Computadorizada de Feixe Cônico (TCFC) utilizando diferentes parâmetros de exposição e analisar a influência da guta- percha, do núcleo metálico fundido e do pino de fibra de vidro no diagnóstico das FRs, assim como a formação de artefatos em TCFC. Cento e sessenta dentes foram selecionados e divididos em quatro grupos de acordo com o material de preenchimento (sem guta-percha, com guta-perch...

  2. The Borromini's helicoidal staircase in Barberini Palace: scan laser survey and parametric modeling.

    Directory of Open Access Journals (Sweden)

    Leonardo Paris

    2015-07-01

    Full Text Available The paper concerns the study of the shape and geometry of the helicoidal staircase in Barberini Palace. Integrated models of representation (graphic and 3D have been produced starting from the digital data acquired by a laser scanner, processed and subsequently managed through procedures for optimizing the cloud-points.The realization of the helicoidal staircase in the Barberini Palace has an important rule in the architectural history because  it is a wonderful example of the constructive development of a complex geometric shape which is a helix oval. This stair should be read and interpreted as evidence of a particular period,the Roman Baroque, rich of intertwining and overlapping of ecclesiastical and noble commissions, of alternations in the yards of the greatest artists and architects of the era, often working simultaneously. Borromini proposes a modification to the first design of Maderno, which included a helicoidal staircase to the right of the large porch entrance to the palace, imagining a new oval stair  with a set of six twin columns for each revolution, very similar to the staircase that had been built a few years earlier, in 1585, at the Quirinale Palace by the Mascherino. Borromini had worked a few years earlier, under the direction of Maderno, in the Quirinal Palace, having a possibility to carefully study the Mascherino’s oval stair .Following the death of Maderno (1629 the yard of the Barberini Palace takes over the Bernini. Borromini will initiate a collaboration destined to end soon. The scale will be built in 1633 when now Borromini had already left the yard.The article wants above all to highlight the correlations between form and geometry when designing a campaign of digital acquisition using a laser scanner. Indeed, there are important implications to choice the positioning points of the instrument, with important fallout on the relationship between quality and quantity of a points cloud. The points cloud is a 3D

  3. Tomografia computadorizada no seguimento de pacientes com tumores intracranianos

    Directory of Open Access Journals (Sweden)

    Gilberto Machado de Almeida

    1981-03-01

    Full Text Available A tomografia computadorizada tem grande valor no controle dos pacientes com tumores cerebrais. Imediatamente após o ato cirúrgico pode ser útil para avaliar a retirada do processo expansivo ou para comprovar a área atingida. Nos primeiros dias após a intervenção tem sido indicada principalmente quando há piora do quadro neurológico. Nestas condições, o exame permite verificar a existência de ar, edema, hematoma, desvios ventriculares e hidrocéfalo. Os dados fornecidos são mais precisos que os obtidos com outros exames neuror-radiológicos ou com a medida contínua da pressão intracraniana, métodos menos inócuos. A longo prazo a tomografia permite o diagnóstico precoce de recidivas, a avaliação da eficácia de tratamentos radio ou quimioterápicos e o controle do hidrocéfalo. Ainda não é possível fazer o diagnóstico diferencial entre radio-necrose e recidiva tumoral.

  4. Biópsia mamária realizada pela técnica de biópsia helicoide: estudo experimental Breast biopsy performed by the helicoid biopsy technique: an experimental study

    Directory of Open Access Journals (Sweden)

    Eliel de Souza

    2010-12-01

    Full Text Available OBJETIVO: avaliar o desempenho da biópsia helicoide na realização de biópsias mamárias. MÉTODOS: foi selecionado aleatoriamente uma amostra composta de 30 pacientes portadoras de câncer de mama submetidas à mastectomia. Foram excluídas as mulheres portadoras de tumor que tivessem consistência pétrea, não-palpável, com manipulação cirúrgica prévia ou que contivesse líquido. Utilizando-se o kit de biópsia helicoide e um equipamento de core biopsy com cânula e agulha de 14 gauge, respectivamente, coletou-se um fragmento por equipamento em área sã e nos tumores, em cada peça cirúrgica, totalizando 120 fragmentos para estudo histológico. Para a análise dos dados, definiu-se um nível de confiança de 95% e utilizou-se o software SPSS, versão 13; o índice de concordância Kappa e o teste paramétrico t de Student. RESULTADOS: a média das idades das pacientes foi de 51,6 anos (±11,1 anos. A core biopsy apresentou sensibilidade de 93,3%, especificidade de 100% e acurácia de 96,7%, enquanto a biópsia helicoide teve sensibilidade de 96,7%, especificidade de 100% e acurácia de 98,3%. Na comparação entre a histologia dos tumores e dos fragmentos de biópsias, houve alto grau de concordância nos diagnósticos (Kappa igual a 0,9, com pPURPOSE: to assess the helicoid biopsy performance when carrying out breast biopsies. METHODS: thirty patients with breast cancer submitted to mastectomy were selected at random. Women with a tumor of petreous consistency, nonpalpable, submitted to previous surgical manipulation or containing fluid were excluded. The helicoid biopsy kit and a core biopsy device with a cannula and a 14-gauge-needle, respectively, were used to collect a fragment each from a healthy area and from the tumor of each surgical specimen, for a total of 120 fragments for histological study. Data were analyzed statistically by the parametric Student's t-test and by the Kappa concordance index at the 95% confidence level

  5. Monte Carlo analysis of thermal transpiration effects in capacitance diaphragm gauges with helicoidal baffle system

    International Nuclear Information System (INIS)

    Vargas, M; Stefanov, S; Wüest, M

    2012-01-01

    The Capacitance Diaphragm Gauge (CDG) is one of the most widely used vacuum gauges in low and middle vacuum ranges. This device consists basically of a very thin ceramic or metal diaphragm which forms one of the electrodes of a cap acitor. The pressure is determined by measuring the variation in the capacitance due to the deflection of the diaphragm caused by the pressure difference established across the membrane. In order to minimize zero drift, some CDGs are operated keeping the sensor at a higher temperature. This difference in the temperature between the sensor and the vacuum chamber makes the behaviour of the gauge non-linear due to thermal transpiration effects. This effect becomes more significant when we move from the transitional flow to the free molecular regime. Besides, CDGs may incorporate different baffle systems to avoid the condensation on the membrane or its contamination. In this work, the thermal transpiration effect on the behaviour of a rarefied gas and on the measurements in a CDG with a helicoidal baffle system is investigated by using the Direct Simulation Monte Carlo method (DSMC). The study covers the behaviour of the system under the whole range of rarefaction, from the continuum up to the free molecular limit and the results are compared with empirical results. Moreover, the influence of the boundary conditions on the thermal transpiration effects is investigated by using Maxwell boundary conditions.

  6. Modulational instability and discrete breathers in a nonlinear helicoidal lattice model

    Science.gov (United States)

    Ding, Jinmin; Wu, Tianle; Chang, Xia; Tang, Bing

    2018-06-01

    We investigate the problem on the discrete modulation instability of plane waves and discrete breather modes in a nonlinear helicoidal lattice model, which is described by a discrete nonlinear Schrödinger equation with the first-, second-, and third-neighbor coupling. By means of the linear stability analysis, we present an analytical expression of the instability growth rate and identify the regions of modulational instability of plane waves. It is shown that the introduction of the third-neighbor coupling will affect the shape of the areas of modulational instability significantly. Based on the results obtained by the modulational instability analysis, we predict the existence conditions for the stationary breather modes. Otherwise, by making use of the semidiscrete multiple-scale method, we obtain analytical solutions of discrete breather modes and analyze their properties for different types of nonlinearities. Our results show that the discrete breathers obtained are stable for a long time only when the system exhibits the repulsive nonlinearity. In addition, it is found that the existence of the stable bright discrete breather closely relates to the presence of the third-neighbor coupling.

  7. Lesões traumáticas do parênquima pulmonar: aspectos na tomografia computadorizada Traumatic lung lesions: computed tomography findings

    Directory of Open Access Journals (Sweden)

    Alessandro Severo Alves de Melo

    2003-06-01

    Full Text Available As lesões pulmonares são achados freqüentes no trauma torácico, sendo cada vez mais diagnosticadas pela tomografia computadorizada, em especial pelo rápido tempo de aquisição decorrente da técnica helicoidal, que permite a avaliação de pacientes em estado grave, possibilitando a adoção de conduta terapêutica eficiente. Os autores estudaram 150 pacientes vítimas de trauma torácico submetidos a tomografia computadorizada, que apresentaram lesões pulmonares, representadas por contusões, atelectasias, lacerações e hematomas pulmonares. As contusões pulmonares se caracterizaram por consolidações e atenuação em vidro fosco, sendo as lesões pulmonares mais comuns. As atelectasias foram observadas com os padrões subsegmentar e compressiva, e foram a segunda lesão mais comum. As lacerações se apresentaram como consolidações com ar ou nível líquido no interior. Os hematomas pulmonares representaram a lesão pulmonar mais rara, presentes em apenas cinco casos, caracterizados por opacidades arredondadas. Neste trabalho o trauma torácico fechado predominou, com 120 casos, enquanto o trauma aberto ocorreu em 30 casos. As causas de trauma fechado, em ordem decrescente de freqüência, foram: colisão automobilística, atropelamento, queda de altura, acidente de motocicleta e espancamento. A forma penetrante de traumatismo torácico decorreu de duas causas de agressão: lesão por arma de fogo e lesão por arma branca.Traumatic lesions of the lung are common findings in patients with thoracic trauma. These lesions are increasingly diagnosed using computed tomography, mostly due to the fast acquisition time helical techniques that allow evaluation of critically ill patients and an efficient therapeutic management. The authors studied 150 patients with thoracic trauma submitted to computed tomography that demonstrated lung contusions, atelectasies, lacerations and hematomas. Lung contusions were the most frequent lesions

  8. Advanced SEM imaging

    International Nuclear Information System (INIS)

    Joy, D. C.; Newbury, D. E.

    1998-01-01

    The scanning electron microscope (SEM) represents the most promising tool for metrology, defect review, and for the analysis of ULSI structures, but both fundamental problems such as electron-solid interactions, and practical considerations such as electron-optical constraints, are now setting a limit to performance. This paper examines the directions in which an advanced SEM might be developed to overcome these constraints. The SEM also offers considerable promise as a tool for the high spatial resolution X-ray microanalysis, especially for those situations where a thin cross-section is not practical and first surface analysis is required. The ways in which this capability can be incorporated in an advanced SEM are examined

  9. Advanced SEM imaging

    International Nuclear Information System (INIS)

    Joy, D.C.; Newbury, D.E.; Newbury, D.E.

    1998-01-01

    The scanning electron microscope (SEM) represents the most promising tool for metrology, defect review, and for the analysis of ULSI structures, but both fundamental problems such as electron-solid interactions, and practical considerations such as electron-optical constraints, are now setting a limit to performance. This paper examines the directions in which an advanced SEM might be developed to overcome these constraints. The SEM also offers considerable promise as a tool for the high spatial resolution X-ray microanalysis, especially for those situations where a thin cross-section is not practical and first surface analysis is required. The ways in which this capability can be incorporated in an advanced SEM are examined. copyright 1998 American Institute of Physics

  10. Tomografia computadorizada aplicada a estudos de um Planossolo

    Directory of Open Access Journals (Sweden)

    Pedrotti Alceu

    2003-01-01

    Full Text Available Na busca de técnicas mais apuradas para a determinação e avaliação de parâmetros físicos do solo com aplicabilidade em várzeas, vem se destacando a tomografia computadorizada, por medir a densidade e a umidade com boa sensibilidade e alta resolução espacial. O presente trabalho teve como objetivo descrever aspectos e procedimentos da calibração de um minitomógrafo de raios-X e gama para estudo da densidade e umidade de um Planossolo no Rio Grande do Sul, bem como estabelecer parâmetros estatísticos para sua adequada utilização. A calibração do minitomógrafo foi obtida pela regressão linear entre as unidades tomográficas (UT, apresentadas pelo programa de reconstrução de imagem, e os coeficientes de atenuação linear (µl, cm-1, medidos por transmissão direta de raios gama, em amostras dos horizontes A e B do Planossolo, água destilada, benzina e alumínio. Para as medidas de transmissão direta de radiação utilizaram-se recipientes com água destilada, benzina, solo e Al, obtendo-se as seguintes fórmulas para o cálculo da densidade do solo no horizonte A: Ds = [(UT/986,16-(0,200xteta]/0,267; e no horizonte B: Ds = [(UT/986,16-(0,200xteta]/0,297, em que UT é o valor médio de UT em cada linha e teta é a umidade volumétrica da amostra de solo, em m³ m-3. Com as configurações obtidas, verificou-se variabilidade média de 2,74% e 0,73%, respectivamente, em termos de homogeneidade e repetibilidade. Os erros atribuídos ao equipamento são de 0,051 e 0,046 Mg m-3, respectivamente, nos horizontes A e B, revelando precisão e adaptabilidade no emprego da técnica em estudos do Planossolo.

  11. Spin-polarized SEM

    International Nuclear Information System (INIS)

    Konoto, Makoto

    2007-01-01

    Development of highly effective evaluation technology of magnetic structures on a nanometric scale is a key to understanding spintronics and related phenomena. A high-resolution spin-polarized scanning electron microscope (spin SEM) developed recently is quite suitable for probing such nanostructures because of the capability of analyzing local magnetization vectors in three dimensions. Utilizing the spin SEM, a layered antiferromagnetic structure with the 1nm-alternation of bilayer-sheet magnetization has been successfully resolved. The real-space imaging with full analysis of the temperature-dependent magnetization vectors will be demonstrated. (author)

  12. SEM microcharacterization of semiconductors

    CERN Document Server

    Holt, D B

    1989-01-01

    Applications of SEM techniques of microcharacterization have proliferated to cover every type of material and virtually every branch of science and technology. This book emphasizes the fundamental physical principles. The first section deals with the foundation of microcharacterization in electron beam instruments and the second deals with the interpretation of the information obtained in the main operating modes of a scanning electron microscope.

  13. É hora de investirmos em intervenções comportamentais computadorizadas no Brasil?

    Directory of Open Access Journals (Sweden)

    Henrique Pinto Gomide

    2013-06-01

    Full Text Available Intervenções comportamentais computadorizadas apresentam evidências de eficácia para diversas condições de saúde, como transtornos de ansiedade ou de humor e abuso do uso de álcool e tabagismo. Embora apresentem efeitos relativamente pequenos, elas podem atingir um grande número de usuários simultaneamente e funcionar de forma ininterrupta. Os objetivos do presente estudo foram: 1 analisar criticamente as evidências de eficácia presentes na literatura sobre intervenções comportamentais computadorizadas; 2 avaliar o potencial de utilização no país; 3 descrever a regulamentação existente; e 4 apresentar ferramentas para desenvolvimento destas intervenções através de uma revisão narrativa da literatura. As intervenções comportamentais computadorizadas se configuram como uma potencial ferramenta para a saúde pública, devido ao crescimento do uso de computadores e internet no Brasil e ao baixo custo de seu desenvolvimento.

  14. Space Experiment Module (SEM)

    Science.gov (United States)

    Brodell, Charles L.

    1999-01-01

    The Space Experiment Module (SEM) Program is an education initiative sponsored by the National Aeronautics and Space Administration (NASA) Shuttle Small Payloads Project. The program provides nationwide educational access to space for Kindergarten through University level students. The SEM program focuses on the science of zero-gravity and microgravity. Within the program, NASA provides small containers or "modules" for students to fly experiments on the Space Shuttle. The experiments are created, designed, built, and implemented by students with teacher and/or mentor guidance. Student experiment modules are flown in a "carrier" which resides in the cargo bay of the Space Shuttle. The carrier supplies power to, and the means to control and collect data from each experiment.

  15. Development of SCAR markers and PCR assays for single or simultaneous species-specific detection of Phytophthora nicotianae and Pythium helicoides in ebb-and-flow irrigated kalanchoe.

    Science.gov (United States)

    Ahonsi, Monday O; Ling, Yin; Kageyama, Koji

    2010-11-01

    Phytophthora nicotianae and Pythium helicoides are important water-borne oomycete pathogens of irrigated ornamentals particularly ebb-and-flow irrigated kalanchoe in Japan. We developed novel PCR-based sequence characterized amplified region markers and assays for rapid identification and species-specific detection of both pathogens in separate PCR reactions or simultaneously in a duplex PCR.

  16. O Cinema sem Imagens

    Directory of Open Access Journals (Sweden)

    Paulo Andrade

    2001-12-01

    Full Text Available A obra cinematográfica de Marguerite Duras, praticamente desconhecida pelo grande público, estabeleça intricadas relações com sua obra literária, ao promover a indiscernibilidade entre os dois campo, sem, contudo, instituir qualquer tipo de subordinação de um ao outro. O processo de criação do filme Lê camion, de 1977, aponta para outras possibilidades de se pensar o cinema e a literatura.

  17. Broncofibroscopia Flexível e Tomografia Helicoidal Computorizada no diagnóstico do Carcinoma Pulmonar Não de Peq uenas Células

    Directory of Open Access Journals (Sweden)

    Ram Cicero

    1998-11-01

    Full Text Available RESUMO: Actualmente a avaliação dos Tumores Pulmonares e as alterações intratorácicas provocadas pelos mesmos pode ser analisada por Tomografia Axial Computorizada e Tomografia Helicoidal Computorizada (THC.Parece haver uma correlação entre as imagens detectadas pela Tomografia Helicoidal Computorizada (THC e as alterações cndoscópicas encontradas por Broncofibroscopia Flexível (BFB.O objectivo deste trabalho foi demonstrar essa eventual correlação.Estudaram-se 18 doentes com Carcinoma do Pulmão Não de Pequenas Células (CPNPC. Houve uma boa correlação da Tomografia Helicoidal Computorizada (THC e dos aspectos encontrados por Broncofibroscopia Flexível (BFB, nas estenoses intrínsecas ou extrínsecas dos Brônquios Principais (BP e Brônquios Lobares (BL.A Tomografa Helicoidal Computorizada (THC pennite a localização espacial do tumor e visualizar as alterações estruturais circunvizinhas secundánas ao crescimento do tumor. A Tomografia Helicoidal Computorizada (THC pennitiu ainda a visualização da árvore brônquica para além da obstrução completa do lúmen brônquico, nos doentes em que não se conseguiu visualizar por broncofibroscopia.Nos tumores periféricos houve demonstração pela Tomografia Helicoidal Computorizada (THC de alterações estruturais da árvore brônquica que por Broncofibroscopia Flexível (BFB foram consideradas normais.Nesta série houve uma correlação directa entre a Tomografia Helicoidal Computorizada (THC e a Broncofibroscopia Flexível (BFB em quinze dos dezoito doentes estudados havendo uma sensibilidade de 83% no diagnóstico do tumor por broncofibroscopia. COMENTÁRIO: A Tomografia Helicoidal Computorizada (THC permite faze r o diagnóstico do cancro do pulmão em três dimensões visualizando as alterações estruturais circunvizinhas.As alterações endoscópicas visualizadas por Broncofibroscopia Flexível (BFB continuam a ser importantes, pela análise macroscópica das lesões e

  18. Mudanças na estrutura do solo avaliada com uso de tomografia computadorizada.

    OpenAIRE

    PIRES, L. F.; BACCHI, O. O. S.

    2010-01-01

    O objetivo deste trabalho foi avaliar, em escala milimétrica, a modificação da densidade e da porosidade de amostras deformadas de solo submetidas a ciclos de umedecimento e secamento (U-S), por meio da tomografia computadorizada de raios gama. Amostras com 98,1 cm³ foram preparadas procedendo ao peneiramento do solo em malha de 2 mm e acondicionamento de forma homogênea em tubos de PVC. As amostras de solo foram submetidas a um, dois e três ciclos de U-S. As amostras controle não foram subme...

  19. Alterações no planejamento em implantodontia utilizando a tomografia computadorizada volumétrica

    OpenAIRE

    Pedroso, Ludmila Assunção de Mello

    2011-01-01

    O sucesso da reabilitação sobre implantes depende de um planejamento bem executado. Nesta fase, as características do sítio e as estruturas anatômicas adjacentes são avaliadas por meio do exame clínico e dos exames por imagem. A radiografia panorâmica é amplamente utilizada, mas recomenda-se que uma imagem seccional seja realizada. A tomografia computadorizada volumétrica (TCV) está entre os exames com maior indicação para essa avaliação. O objetivo deste trabalho foi verifi...

  20. SEM analysis for irradiated materials

    International Nuclear Information System (INIS)

    Liu Xiaosong; Yao Liang

    2008-06-01

    A radiation-proof Scanning Electron Microscope (SEM) system is introduced. It has been widely used in various areas. For analyzing radioactive samples, normal SEM system needs lots of alterations. Based on KYKY-2800B SEM, the sample room, belt line, operating table and aerator were updated. New radiation-proof SEM system has used to analytic surface contaminated samples and RPV materials samples. An elementary means of SEM analysis for radioactive samples was studied, and this examination supported some available references for further irradiated fuel researches. (authors)

  1. Densitometria da vértebra dorsal, osso pleural e osso neural em tartarugas verdes hígidas por tomografia computadorizada quantitativa Densitometry of dorsal vertebrae, pleural bone and neural bone in healthy green sea turtles by quantitative computed tomography

    Directory of Open Access Journals (Sweden)

    Jannine Forattini de Oliveira

    2012-08-01

    Full Text Available A tomografia computadorizada quantitativa (TCQ é uma técnica com alta sensibilidade, aplicabilidade e precisão no diagnóstico de perda de massa óssea, entretanto a falta de valores de normalidade para animais silvestres limita a sua aplicação clínica. O presente estudo objetiva estabelecer valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural de tartarugas marinhas juvenis hígidas utilizando a TCQ. Para isso, utilizou-se um grupo experimental de cinco animais que foram submetidos a exames de tomografia computadorizada helicoidal, sendo as mensurações da radiodensidade óssea realizadas ao nível da terceira, quarta e quinta vértebras dorsais. Os valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural foram, respectivamente, de 287,4±39,1, 1093,74±100,4 e 1089,6±86,5 unidades Hounsfield (HU. Estudos complementares devem ser realizados em diferentes espécies e faixas etárias de quelônios para favorecer a aplicação clínica desta técnica.Quantitative computed tomography (QCT is a technique with high sensitivity, applicability and accuracy in the diagnosis of bone loss; however the lack of normal values for wild animals limits their clinical application. This study aims to establish medium values radiodensity trabecular bone of the dorsal vertebrae, bone pleural and neural bone in healthy juvenile sea turtles using the QTC. For this we used an experimental group of five animals that underwent helical computed tomography, and measurements of bone radiodensity conducted at the level of the third, fourth and fifth dorsal vertebrae. The medium values of radiodensity trabecular bone of the dorsal vertebrae, pleural bone, and neural bone were respectively 287.4±39.1, 1093.74±100.4, and 1089.6±86.5 Hounsfield units (HU. Further studies should be performed in different species and ages of turtles to encourage the clinical application of

  2. Towards chiral distributions of dopants in microporous frameworks: helicoidal supramolecular arrangement of (1R,2S)-ephedrine and transfer of chirality.

    Science.gov (United States)

    Gómez-Hortigüela, Luis; Álvaro-Muñoz, Teresa; Bernardo-Maestro, Beatriz; Pérez-Pariente, Joaquín

    2015-01-07

    A molecular-mechanics computational study is performed in order to analyze the arrangement of (1R,2S)-(-)-ephedrine molecules within the 12-MR channels of the AFI aluminophosphate microporous framework and the influence on the spatial distribution of dopants embedded in the tetrahedral network. Results showed that ephedrine molecules arrange exclusively as dimers by π-π stacking of the aromatic rings within the AFI channels. Interestingly, the asymmetric nature of ephedrine and the presence of H-bond-forming groups (NH2 and OH) involve a preferential orientation where consecutive dimers within the channels are rotated by an angle of +30°; this is driven by the establishment of inter-dimer H-bonds. This preferential orientation leads to the development of a supramolecular enantiomerically-pure helicoidal (chiral) arrangement of ephedrine dimers. In addition, the computational results demonstrate that the particular molecular structure of ephedrine imparts a strong trend to attract negative charges to the vicinity of the NH2(+) positively-charged groups. Hence divalent dopants such as Mg, whose replacement by trivalent Al in the aluminophosphate network involves the generation of a negative charge, will tend to locate close to the NH2(+) molecular groups, suggesting that an imprinting of the organic arrangement to the spatial distribution of dopants would be feasible. Combined with the trend of ephedrine to arrange in a helicoidal fashion, an enantiomerically-pure helicoidal distribution of dopants would be expected, thus inducing a new type of chirality in microporous materials.

  3. Avaliação da expansão rápida da maxila por meio da tomografia computadorizada: relato de um caso Computed tomography evaluation of rapid maxillary expansion: a case report

    Directory of Open Access Journals (Sweden)

    Daniela Gamba Garib

    2005-08-01

    Full Text Available Este trabalho descreve os efeitos dentoesqueléticos e periodontais da expansão rápida da maxila (ERM, avaliados por meio da tomografia computadorizada (TC, em uma jovem de 11,6 anos de idade com má oclusão de Classe I e mordida cruzada posterior unilateral funcional. Durante a fase ativa da ERM, o expansor dentossuportado com parafuso Hyrax foi ativado 7mm. A paciente submeteu-se ao exame de TC helicoidal, antes da expansão e após a remoção do aparelho expansor, findo o período de três meses de contenção. Realizaram-se cortes axiais, de um milímetro de espessura, paralelamente ao plano palatino, englobando as regiões dentoalveolar e basal da maxila, até o terço inferior da cavidade nasal. Utilizando-se o recurso de reconstruções multiplanares, mensuraram-se pelo método computadorizado: as dimensões transversas maxilares, a inclinação dos dentes posteriores, a espessura das tábuas ósseas vestibular e lingual, e o nível da crista óssea alveolar vestibular. A expansão rápida da maaxila ocasionou um significante aumento transverso em todas as regiões aferidas, com magnitude decrescente do arco dentário para a base óssea. Os dentes posteriores foram movimentados para vestibular, com um componente de inclinação e translação associados. Tal efeito ortodôntico ocasionou uma redução na espessura da tábua óssea vestibular, e um concomitante aumento na espessura da tábua óssea lingual. Após a expansão, observou-se o desenvolvimento de deiscências ósseas por vestibular dos dentes de ancoragem.This paper presents a computed tomography (CT evaluation of rapid maxillary expansion dentoskeletal and periodontal effects, in a 11.6 year-old girl presenting Class I malocclusion with posterior unilateral crossbite. The tooth-borne expander with Hyrax screw was activated 7-mm. The patient was submitted to helicoidal CT scan before expansion and after the three-month retention period when the expander was removed. Axial

  4. Tomografia computadorizada do cranio no diagnostico dos meningiomas: registro de 16 casos

    Directory of Open Access Journals (Sweden)

    James Pitagoras de Mattos

    1983-03-01

    Full Text Available Os autores se referem à importância do emprego da tomografia computadorizada do crânio para o preciso diagnóstico dos meningiomas. Constam da experiência 16 casos, comprovados cirúrgica e histologicamente. A média de idade foi de 52,1 anos, sendo 10 pacientes do sexo feminino e 6 do masculino. Quanto à localização, 5 eram da cavidade orbitrária e/ou asa do esfenóide, 3 parasagitais, 3 da foice, 2 supra-selares, 2 de convexidade e 1 do tentório. Concluem tratar-se de exame de grande positividade (95-98%, praticamente inócuo e que permite, na atualidade, o diagnóstico precoce conduzindo, consequentemente, a melhores resultados terapêuticos.

  5. Histiocitoma fibroso benigno profundo: achados na tomografia computadorizada e histologia Deep benign fibrous histiocytoma: computed tomography and histology findings

    Directory of Open Access Journals (Sweden)

    Luciano Farage

    2005-04-01

    Full Text Available Apresentamos imagens de tomografia computadorizada de um paciente de 83 anos de idade com histiocitoma fibroso benigno profundo, na face lateral da perna esquerda, com evolução de longa data. À tomografia computadorizada observamos massa bem delimitada, ovalada, e que apresentava intenso realce periférico com uso do meio de contraste iodado. Este é um tumor de partes moles pouco freqüente e com raros relatos dos seus aspectos de imagem.We present the computed tomography images of an 83-year-old male patient with a deep benign fibrous histiocytoma at the lateral aspect of the left leg. Computed tomography images showed a well-defined mass with marked peripheral enhancement by iodinated contrast medium. Only few reports of this rare soft tissue tumor can be found in the literature.

  6. Tomografia computadorizada em pacientes portadores de neurocisticercose com hipertensão intracraniana por hidrocefalia obstrutiva: comparação com ventriculografia com Dimer-X

    Directory of Open Access Journals (Sweden)

    Benedicto Oscar Colli

    1984-06-01

    Full Text Available Estudo das alterações observadas nas tomografias computadorizadas (TCs de 16 casos de neurocisticercose, com hipertensão intracraniana por hidrocefalia. Todos os casos foram submetidos a radiografias simples do crânio e 12, à ventriculografia com Dimer-X. Nas radiografias simples foram observados sinais de hipertensão intracraniana em 7, calcificações em um, e d foram normais. A TC mostrou parênquima cerebral normal em 9 casos e nos 7 restantes áreas hipodensas arredondadas de tamanho variado, com ou sem retenção de contraste na periferia, e/ou calcificações esparsas no parenquima. Hidrocefalia foi a única alteração observada no sistema ventricular nos casos em que o exame foi realizado previamente à derivação do LCR. As ventriculografias foram analisadas em trabalho anterior e permitiram localizar e determinar as características da obstrução e a presença de massas ocupando espaço dentro dos ventrículos. A comparação das ventriculografias e TCs realizadas na mesma época evidenciou que a primeira fornece melhores informações sobre o sistema ventricular mas, por outro lado, a tomografia fornece informações adicionais sobre o parênquima cerebral. A TC e a ventriculografia são exames que se completam na avaliação e no diagnóstico destes pacientes.

  7. Secondary emission monitor (SEM) grids.

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    A great variety of Secondary Emission Monitors (SEM) are used all over the PS Complex. At other accelerators they are also called wire-grids, harps, etc. They are used to measure beam density profiles (from which beam size and emittance can be derived) in single-pass locations (not on circulating beams). Top left: two individual wire-planes. Top right: a combination of a horizontal and a vertical wire plane. Bottom left: a ribbon grid in its frame, with connecting wires. Bottom right: a SEM-grid with its insertion/retraction mechanism.

  8. HELICoiD project: a new use of hyperspectral imaging for brain cancer detection in real-time during neurosurgical operations

    Science.gov (United States)

    Fabelo, Himar; Ortega, Samuel; Kabwama, Silvester; Callico, Gustavo M.; Bulters, Diederik; Szolna, Adam; Pineiro, Juan F.; Sarmiento, Roberto

    2016-05-01

    Hyperspectral images allow obtaining large amounts of information about the surface of the scene that is captured by the sensor. Using this information and a set of complex classification algorithms is possible to determine which material or substance is located in each pixel. The HELICoiD (HypErspectraL Imaging Cancer Detection) project is a European FET project that has the goal to develop a demonstrator capable to discriminate, with high precision, between normal and tumour tissues, operating in real-time, during neurosurgical operations. This demonstrator could help the neurosurgeons in the process of brain tumour resection, avoiding the excessive extraction of normal tissue and unintentionally leaving small remnants of tumour. Such precise delimitation of the tumour boundaries will improve the results of the surgery. The HELICoiD demonstrator is composed of two hyperspectral cameras obtained from Headwall. The first one in the spectral range from 400 to 1000 nm (visible and near infrared) and the second one in the spectral range from 900 to 1700 nm (near infrared). The demonstrator also includes an illumination system that covers the spectral range from 400 nm to 2200 nm. A data processing unit is in charge of managing all the parts of the demonstrator, and a high performance platform aims to accelerate the hyperspectral image classification process. Each one of these elements is installed in a customized structure specially designed for surgical environments. Preliminary results of the classification algorithms offer high accuracy (over 95%) in the discrimination between normal and tumour tissues.

  9. Chlorella vulgaris as a lipid source: Cultivation on air and seawater-simulating medium in a helicoidal photobioreactor.

    Science.gov (United States)

    Frumento, Davide; Aliakbarian, Bahar; Casazza, Alessandro Alberto; Converti, Attilio; Al Arni, Saleh; da Silva, Milena Fernandes

    2016-03-01

    The freshwater microalga Chlorella vulgaris was cultured batchwise on the seawater-simulating Schlösser medium either in a 1.1-L-working volume helicoidal photobioreactor (HeP) or Erlenmeyer flask (EF) as control and continuously supplying air as CO2 source. In these systems, maximum biomass concentration reached 1.65 ± 0.17 g L(-1) and 1.25 ± 0.06 g L(-1) , and maximum cell productivity 197.6 ± 20.4 mg L(-1)  day(-1) and 160.8 ± 12.2 mg L(-1)  day(-1) , respectively. Compared to the Bold's Basal medium, commonly employed to cultivate this microorganism on a bench-scale, the Schlösser medium ensured significant increases in all the growth parameters, namely maximum cell concentration (268% in EF and 126% in HeP), maximum biomass productivity (554% in EF and 72% in HeP), average specific growth rate (67% in EF and 42% in HeP), and maximum specific growth rate (233% in EF and 22% in HeP). The lipid fraction of biomass collected at the end of runs was analyzed in terms of both lipid content and fatty acid profile. It was found that the seawater-simulating medium, despite of a 56-63% reduction of the overall biomass lipid content compared to the Bold's Basal one, led in HeP to significant increases in both the glycerides-to-total lipid ratio and polyunsaturated fatty acid content compared to the other conditions taken as an average. These results as a whole suggest that the HeP configuration could be a successful alternative to the present means to cultivate C. vulgaris as a lipid source. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:279-284, 2016. © 2016 American Institute of Chemical Engineers.

  10. SEM: A Cultural Change Agent

    Science.gov (United States)

    Barnes, Bradley; Bourke, Brian

    2015-01-01

    The authors advance the concept that institutional culture is a purposeful framework by which to view SEM's utility, particularly as a cultural change agent. Through the connection of seemingly independent functions of performance and behavior, implications emerge that deepen the understanding of the influence of culture on performance outcomes…

  11. Actitudes de los candidatos y maestros de ciencias en servicio acerca del uso de las herramientas computadorizadas en las clases de ciencias

    Science.gov (United States)

    Bayuelo, Ezequiel

    Este estudio examino y comparo las actitudes de los candidatos a maestros de ciencias y los maestros de ciencias en servicio acerca de la utilizacion de las herramientas computadorizadas en las clases de ciencias. Tambien identifico y diferencio el uso que ellos dan a estas herramientas en las clases de ciencias. Este estudio presenta un diseno descriptivo exploratorio. Constituyeron la muestra trescientos diez sujetos que fueron candidatos a maestros de ciencias o maestros de ciencias en servicio. Para recoger los datos se construyo y valido un cuestionario de treinta y un itemes. Se utilizaron las pruebas estadisticas no parametricas Kruskal Wallis y Chi-cuadrado (test de homogeneidad) para establecer las diferencias entre las actitudes de los sujetos con relacion al uso de las herramientas computadorizadas en las clases de ciencias. Los hallazgos evidenciaron que son positivas y muy parecidas las actitudes de los candidatos a maestros y maestros en servicio hacia el uso de las herramientas computadorizadas. No hubo diferencias entre los candidatos y maestros en servicio en terminos de las actitudes de confianza y empatia hacia el uso de las herramientas computadorizadas en las clases de ciencias. En aspectos como el uso del banco de datos bibliografico Eric y el uso de las herramientas computadorizadas en actividades educativas como explorar conceptos, conceptuar, aplicar lo aprendido y hacer asignaciones hubo diferencias estadisticamente significativas entre los candidatos y los maestros en servicio. Al comparar las frecuencias observadas con las esperadas hubo mas maestros en servicio y menos candidatos que indicaron usar el anterior banco de datos y las herramientas computadorizadas en las mencionadas actividades educativas.

  12. Efeitos da ibopamina 2% tópica nos resultados da campimetria visual computadorizada Effects of 2% ibopamine eye drops on computerized visual field results

    Directory of Open Access Journals (Sweden)

    Mara Agi Pigini

    2009-06-01

    Full Text Available OBJETIVO: Avaliar os efeitos do uso do colírio de ibopamina a 2% nos resultados da campimetria visual computadorizada em indivíduos normais. MÉTODOS: Voluntários oriundos do CEROF-UFG, sem alterações ao exame oftalmológico que pudessem afetar o campo visual foram selecionados. Os indivíduos foram submetidos a exame de perimetria computadorizada SITA-standard 24-2 antes e após dilatação com o colírio de ibopamina a 2% ou ciclopentolato, com intervalo mínimo de 3 dias entre si e em ordem aleatória. Índices globais e número de pontos alterados foram comparados entre os grupos. RESULTADOS: Foram avaliados 30 olhos de 30 indivíduos normais. Não houve diferença estatisticamente significativa entre o "mean deviation" (MD nos pacientes não dilatados e nos mesmos após a instilação da ibopamina (MD: -1,05 ± 0,26 dB vs. -1,47 ± 0,20 dB, P=0,08, o que ocorreu após cicloplegia (MD: -3,19 ± 0,29 dB, PPURPOSE: To evaluate the influence of 2% ibopamine eye drops on the results of computerized visual field exams. METHODS: Normal volunteers from CEROF-UFG were selected, with no variance in the ophthalmologic examination that could affect the visual field test. The volunteers underwent computerized visual field test before and after dilation with 2% ibopamine eye drop or cyclopentolate, with a minimum interval of three days between them and in a random order. Global indices and number of altered points were compared between the groups. RESULTS: Thirty eyes of 30 normal individuals were selected. There was no statistically significant difference on Mean Deviation (MD before and after dilation with ibopamine (MD: -1.05 ± 0.26 dB vs. -1.47 ± 0.20 dB, P=0.08. However, after cycloplegia (MD: -3.19 ± 0.29 dB, there was a significant difference on MD (P<0.001 for both ibopamine and pre-dilation. No significant difference was detected in the Pattern Standard Deviation when comparing ibopamine with pre-dilation and cycloplegia values, but it

  13. Análise do perfil facial masculino adulto jovem, esteticamente agradável, em fotografias padronizadas: comparação da medição manual com a computadorizada Facial profile analysis of esthetically harmonious young male adults in standardized photographs: comparison of manual versus computerized measurements

    OpenAIRE

    Isabella Cabral Alexandre Schlickmann; Alexandre Moro; Adilson dos Anjos

    2008-01-01

    OBJETIVO: analisar o perfil facial masculino adulto jovem, através de fotografias padronizadas e comparar a medição manual com a medição computadorizada por meio do software Cef X (CDT). MÉTODOS: a amostra consistiu de 40 indivíduos brasileiros brancos, com média de idade de 21,9 anos, que possuíam perfis agradáveis, oclusão normal, sem histórico de tratamento ortodôntico prévio. As fotografias coloridas de 10cm x 15cm foram obtidas de forma padronizada, com o indivíduo na posição natural da ...

  14. Framework for SEM contour analysis

    Science.gov (United States)

    Schneider, L.; Farys, V.; Serret, E.; Fenouillet-Beranger, C.

    2017-03-01

    SEM images provide valuable information about patterning capability. Geometrical properties such as Critical Dimension (CD) can be extracted from them and are used to calibrate OPC models, thus making OPC more robust and reliable. However, there is currently a shortage of appropriate metrology tools to inspect complex two-dimensional patterns in the same way as one would work with simple one-dimensional patterns. In this article we present a full framework for the analysis of SEM images. It has been proven to be fast, reliable and robust for every type of structure, and particularly for two-dimensional structures. To achieve this result, several innovative solutions have been developed and will be presented in the following pages. Firstly, we will present a new noise filter which is used to reduce noise on SEM images, followed by an efficient topography identifier, and finally we will describe the use of a topological skeleton as a measurement tool that can extend CD measurements on all kinds of patterns.

  15. SEM-based characterization techniques

    International Nuclear Information System (INIS)

    Russell, P.E.

    1986-01-01

    The scanning electron microscope is now a common instrument in materials characterization laboratories. The basic role of the SEM as a topographic imaging system has steadily been expanding to include a variety of SEM-based analytical techniques. These techniques cover the range of basic semiconductor materials characterization to live-time device characterization of operating LSI or VLSI devices. This paper introduces many of the more commonly used techniques, describes the modifications or additions to a conventional SEM required to utilize the techniques, and gives examples of the use of such techniques. First, the types of signals available from a sample being irradiated by an electron beam are reviewed. Then, where applicable, the type of spectroscopy or microscopy which has evolved to utilize the various signal types are described. This is followed by specific examples of the use of such techniques to solve problems related to semiconductor technology. Techniques emphasized include: x-ray fluorescence spectroscopy, electron beam induced current (EBIC), stroboscopic voltage analysis, cathodoluminescnece and electron beam IC metrology. Current and future trends of some of the these techniques, as related to the semiconductor industry are discussed

  16. Estimativa dos valores de MSAD em procedimentos de tomografia computadorizada utilizando filmes radiocrômicos

    Directory of Open Access Journals (Sweden)

    Bruno Beraldo Oliveira

    2013-04-01

    Full Text Available OBJETIVO: Verificar a viabilidade de filmes radiocrômicos como um dosímetro alternativo para estimativa da dose média em cortes múltiplos a partir dos perfis de kerma. MATERIAIS E MÉTODOS: Os filmes foram distribuídos em cilindros posicionados no centro e nas regiões periféricas de um objeto simulador padrão de abdome utilizado para dosimetria em tomografia computadorizada. RESULTADOS: Os valores de dose média em cortes múltiplos calculados foram 13,6 ± 0,7, 13,5 ± 0,7 e 18,7 ± 1,0 mGy para os valores de passo (pitch de 0,75, 1,00 e 1,50, respectivamente. CONCLUSÃO: Apesar de os resultados mostrarem valores menores que o nível de referência de radiodiagnóstico de 25 mGy estabelecido pela legislação brasileira para exames de abdome, eles sugerem que há espaço para otimização dos procedimentos e uma revisão do valor para o nível de referência de radiodiagnóstico brasileiro.

  17. Trauma dos ossos temporais e suas complicações: aspectos na tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Ana Maria Doffémond Costa

    2013-04-01

    Full Text Available A maioria das fraturas dos ossos temporais resulta de traumas cranianos bruscos, de alta energia, estando muitas vezes relacionadas a outras fraturas cranianas ou a politraumatismo. As fraturas e os deslocamentos da cadeia ossicular, na orelha média, representam umas das principais complicações das injúrias nos ossos temporais e, por isso, serão abordadas de maneira mais profunda neste artigo. Os outros tipos de injúrias englobam as fraturas labirínticas, fístula dural, paralisia facial e extensão da linha de fratura ao canal carotídeo. A tomografia computadorizada tem papel fundamental na avaliação inicial dos pacientes politraumatizados, pois é capaz de identificar injúrias em importantes estruturas que podem causar graves complicações, como perda auditiva de condução ou neurossensorial, tonturas e disfunções do equilíbrio, fístulas perilinfáticas, paralisia do nervo facial, lesões vasculares, entre outras.

  18. Avaliação da anatomia de molares decíduos por meio de microtomografia computadorizada

    OpenAIRE

    Ana Caroline Fumes

    2013-01-01

    O conhecimento prévio da anatomia interna e externa dos dentes decíduos é de fundamental importância para o sucesso do tratamento endodôntico. O objetivo do presente estudo foi analisar a morfologia das raízes e dos canais radiculares de molares decíduos superiores e inferiores, por meio de microtomografia computadorizada (micro-CT). Foram usados 40 molares decíduos, divididos em quatro grupos, sendo 10 primeiros molares inferiores, 10 segundos molares inferiores, 10 primeiros molares superio...

  19. Malária pulmonar: aspectos na tomografia computadorizada de alta resolução - relato de caso

    Directory of Open Access Journals (Sweden)

    Rodrigues Rosana

    2004-01-01

    Full Text Available Neste trabalho é relatado o caso de paciente do sexo masculino, de 38 anos de idade, que desenvolveu quadro de malária com comprometimento pulmonar. A tomografia computadorizada de alta resolução evidenciou espessamento de septos interlobulares e de bainhas peribroncovasculares, com áreas esparsas de atenuação em vidro fosco e de consolidações, além de derrame pleural bilateral, aspectos compatíveis com edema pulmonar. O paciente recebeu tratamento específico, evoluindo bem e tendo alta 11 dias após a internação.

  20. International Conference on SEMS 2012

    CERN Document Server

    Liu, Chuang; Scientific explanation and methodology of science; SEMS 2012

    2014-01-01

    This volume contains the contributed papers of invitees to SEMS 2012 who have also given talks at the conference. The invitees are experts in philosophy of science and technology from Asia (besides China), Australia, Europe, Latin America, North America, as well as from within China. The papers in this volume represent the latest work of each researcher in his or her expertise; and as a result, they give a good representation of the cutting-edge researches in diverse areas in different parts of the world.

  1. Comparação morfométrica da orelha interna entre ovinos e humanos através da tomografia computadorizada CT-Scan sheep and human inner ear morphometric comparison

    Directory of Open Access Journals (Sweden)

    Valter Ayres Seibel

    2006-06-01

    Full Text Available INTRODUÇÃO: trabalhos sobre o uso de ovelhas em cirurgias experimentais e treinamento em cirurgia otológica são raros. Este estudo pretende contribuir para ampliar o conhecimento nessa área. OBJETIVO: Estudar a orelha interna da ovelha por meio de tomografia computadorizada e cortes sucessivos com o intuito de apresentar dados morfométricos mais precisos relacionados à comparação entre a orelha de ovelhas e a de humanos. MATERIAL E MÉTODO: Foi realizado um estudo descritivo sem seguimento no qual foram comparadas as estruturas da orelha interna da ovelha com as dos humanos. As medidas foram obtidas através de tomografias computadorizadas e avaliadas por meio de um programa de análise de imagens médicas (Osíris 4.16. RESULTADOS: O estudo morfológico da orelha da ovelha, em média, e da orelha humana, em média, revelaram grande similaridade de anatomia. A maior parte das estruturas (10 de 15 preservou a relação proposta de 2/3 da dimensão humana em relação à dimensão ovina. CONCLUSÃO: Os achados contribuem para uso da orelha da ovelha como modelo em cirurgia experimental e treinamento em cirurgia otológica.INTRODUCTION: Studies about the use of sheep in surgical training and experimental otologic surgery are rare. This study intends to contribute to the knowledge on this field. AIM: To study sheep inner ear structures using computerized tomography and serial cross-sections to collect more accurate morphometric data to compare sheep and human ears. MATERIAL AND METHODS: This descriptive study compared the inner structures of sheep and human ears. Measurements were made using computerized tomography, and they were stored in a DICOM compact disc for later analysis and manipulation, with a program used for medical image analysis (Osíris 4.16. RESULTS: Mean measures for sheep and human ears were found to be similar in this morphological study. Most structures (10 out of 15 maintained the 2/3 ratio of sheep to human ear

  2. Quando a fase de equilíbrio pode ser suprimida nos exames de tomografia computadorizada de abdome? What is the real role of the equilibrium phase in abdominal computed tomography?

    Directory of Open Access Journals (Sweden)

    Priscila Silveira Salvadori

    2013-04-01

    Full Text Available OBJETIVO: Avaliar a necessidade de realização da fase de equilíbrio nos exames de tomografia computadorizada de abdome. MATERIAIS E MÉTODOS: Realizou-se estudo retrospectivo, transversal e observacional, avaliando 219 exames consecutivos de tomografia computadorizada de abdome com contraste intravenoso, realizados num período de três meses, com diversas indicações clínicas. Para cada exame foram emitidos dois pareceres, um avaliando o exame sem a fase de equilíbrio (primeira análise e o outro avaliando todas as fases em conjunto (segunda análise. Ao final de cada avaliação, foi estabelecido se houve mudança nos diagnósticos principais e secundários, entre a primeira e a segunda análise. Foi utilizada a extensão do teste exato de Fisher para avaliar a modificação dos diagnósticos principais (p 0,999. Com relação aos diagnósticos secundários, cinco exames (2,3% foram modificados. CONCLUSÃO: Para indicações clínicas como estadiamento tumoral, abdome agudo e pesquisa de coleção abdominal, a fase de equilíbrio não acrescenta contribuição diagnóstica expressiva, podendo ser suprimida dos protocolos de exame.OBJECTIVE: To evaluate the role of the equilibrium phase in abdominal computed tomography. MATERIALS AND METHODS: A retrospective, cross-sectional, observational study reviewed 219 consecutive contrast-enhanced abdominal computed tomography images acquired in a three-month period, for different clinical indications. For each study, two reports were issued - one based on the initial analysis of non-contrast-enhanced, arterial and portal phases only (first analysis, and a second reading of these phases added to the equilibrium phase (second analysis. At the end of both readings, differences between primary and secondary diagnoses were pointed out and recorded, in order to measure the impact of suppressing the equilibrium phase on the clinical outcome for each of the patients. The extension of the exact Fisher

  3. Tomografia Computadorizada de crânio em perícias criminais: uma grande aliada

    Directory of Open Access Journals (Sweden)

    Márcio Gleidson Ribeiro Dias

    2016-11-01

    Full Text Available O presente estudo trata-se de uma revisão descritiva da literatura sobre as principais vantagens da Tomografia Computadorizada (TC de crânio na área de Criminologia. Para a revisão literária foram utilizados artigos e dissertações recentes publicados entre 2007 e 2016, livros de imagenologia e medicina legal. A partir dos dados obtidos na revisão literária, nós realizamos uma descrição sobre a TC e sua evolução ao longo dos anos, suas vantagens e aplicações em perícias criminais. Destacamos a importância do laudo pericial, a responsabilidade do perito criminal, a fisiopatologia do trauma cranioencefálico e a sua relação com a violência urbana.Entre as vantagens da virtópsia em relação aos métodos tradicionais destacam-se a preservação do corpo, o arquivamento das imagens e a capacidade de identificação de vítimas através de imagens comparativas ante mortem e post mortem. Assim, a TC tem se tornado cada vez mais presente nas investigações criminais como uma tecnologia de baixo custo que é capaz de localizar, quantificar e evidenciar o trajeto de projéteis, auxiliando na identificação de cadáveres e causas da morte.

  4. Tomografia computadorizada das células etmoidais intra e extramurais: ensaio iconográfico

    Directory of Open Access Journals (Sweden)

    Fabrício Guimarães Gonçalves

    2011-10-01

    Full Text Available O desenvolvimento dos seios paranasais é um processo intricado que se inicia na vida intrauterina e termina na idade adulta. Dos seios da face, as células etmoidais são provavelmente as estruturas mais complexas e as que estão associadas com o maior número de variantes da normalidade. Variações no padrão de pneumatização das células etmoidais podem ser divididas em intra ou extramurais. Intramurais são aquelas que ao se desenvolverem mantêm contato com o labirinto etmoidal, e extramurais as que se desenvolvem isoladamente. A tomografia computadorizada é a ferramenta mais útil na avaliação de processos inflamatórios dos seios paranasais. De igual modo, ela é importante para o planejamento pré-operatório e controle pós-operatório, pois possibilita grande detalhe anatômico das estruturas normais e detecção precisa de suas variantes. Neste ensaio iconográfico os autores descrevem as principais variantes da normalidade do labirinto etmoidal e suas relações com estruturas adjacentes. Cirurgias endoscópicas para o tratamento de afecções dos seios paranasais têm-se tornado cada vez menos invasivas, o que certamente aumentará a demanda por relatórios de imagem cada vez mais ricos em detalhes desta região.

  5. The Effect of Nonnormality on CB-SEM and PLS-SEM Path Estimates

    OpenAIRE

    Z. Jannoo; B. W. Yap; N. Auchoybur; M. A. Lazim

    2014-01-01

    The two common approaches to Structural Equation Modeling (SEM) are the Covariance-Based SEM (CB-SEM) and Partial Least Squares SEM (PLS-SEM). There is much debate on the performance of CB-SEM and PLS-SEM for small sample size and when distributions are nonnormal. This study evaluates the performance of CB-SEM and PLS-SEM under normality and nonnormality conditions via a simulation. Monte Carlo Simulation in R programming language was employed to generate data based on the theoretical model w...

  6. Study of the failure in service of a linepipe, helicoidally welded, quality API SL GrB wich conveyed natural gas. Estudio del fallo en servicio de una tuberia soldada helicoidalmente de calidad API SL SrB que transportaba gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez de Saiz-Solabarria, S.; Elices, M.A. (Departamento de Ciencias de los Materiales e Ingenieria Metalurgica, Universidad del Pais Vasco, Bilbao (Spain))

    1994-01-01

    The possible causes are studied which have incidentally provoked a failure in service on a natural gas linepipe run. This pipe has been manufactured with 6 mm-thick-plate-coil helicoidally welded to 273 mm external diameter. The quality of the material is up to standard API 5L for Grade B and an automatic-helicoidally welding procedure has been with simultaneous inflow at both internal and and external surfaces. The failure appears together with deformations and fracture. (Author)

  7. Sexual Arousal and Sexually Explicit Media (SEM)

    DEFF Research Database (Denmark)

    Hald, Gert Martin; Stulhofer, Aleksandar; Lange, Theis

    2018-01-01

    -mainstream and mainstream SEM groups, and (iii) to explore the validity and predictive accuracy of the Non-Mainstream Pornography Arousal Scale (NPAS). METHODS: Online cross-sectional survey of 2,035 regular SEM users in Croatia. MAIN OUTCOMES MEASURES: Patterns of sexual arousal to 27 different SEM themes, sexual...

  8. Lesões traumáticas do tórax. Aspectos na tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Alessandro Severo Alves de Melo

    2004-09-01

    Full Text Available RESUMO: O trauma representa, no mundo actual, uma das principais causas de morte, e o acometimento torácico significa um importante agravamento nas vítimas de trauma multi-sistémico. Neste trabalho foram estudados os aspectos tomográficos de 200 pacientes com trauma torácico. As lesões pulmonares predominaram, tendo sido observadas em 192 casos (96%, manifestadas sob a forma de contusões em 178 casos (89%, atelectasias em 41 casos (20,5%, lacerações em 15 casos (7,5% e hematomas em 6 casos (3%. Lesões pleurais foram demonstradas em 140 casos (70%, dos quais em 121 casos (60,5% havia hemotórax e em 84 casos (42% pneumotórax. As lesões mediastínicas estiveram presentes em 28 casos (14%, com pneumomediastino em 18 (9%, hematoma mediastínico em 7 casos (3,5%, hemopericárdio em 4 (2% e lesões da aorta em 3 (1,5%. As lesões diafragmáticas foram observadas em 8 pacientes (4%. O enfisema de partes moles foi demonstrado em 36 casos (18%.REV PORT PNEUMOL 2004; X (5: 393-403 ABSTRACT: Trauma is nowadays one of the most common causes of death and traumatic thoracic lesions are important agravant to trauma patients. In this work the aspects of computed tomography from 200 cases of thoracic trauma were studied. Lung lesions predominated, found in 192 cases (96%, manifested as contusions in 178 cases (89%, atelectasis in 41 cases (20,5%, lacerations in 15 cases (7,5% and hematomas in 6 cases (3%. Pleural lesions were showed in 140 cases (70%, among them in 121 cases (60,5% there were hemothorax and in 84 cases (42%, pneumothorax. Mediastinal lesions were observed in 28 cases (14%, with pneumomediastinum in 18 cases (9%, mediastinal hematoma in 7 cases (3,5%, hemopericardium in 4 cases (2% and aortic lesions in 3 cases (1,5%. Diaphragmatic rupture was seen in 8 pacients (4%. Soft tissue emphysema was demonstrated in 36 cases (18%.REV PORT PNEUMOL 2004; X (5: 393-403 Palavras-chave: Tórax, tomografia computadorizada, trauma torácico, Key

  9. Apendicite aguda: achados na tomografia computadorizada - ensaio iconográfico Acute appendicitis: computed tomography findings - an iconographic essay

    Directory of Open Access Journals (Sweden)

    Marcelo Eustáquio Montandon Júnior

    2007-06-01

    Full Text Available A apendicite aguda é a causa mais comum de dor abdominal aguda que requer intervenção cirúrgica no mundo ocidental. O diagnóstico precoce é essencial para minimizar a morbidade da doença. O uso dos métodos de imagem significou grande avanço no diagnóstico desta entidade, até então avaliada apenas com base na história clínica, exame físico e dados laboratoriais, haja vista que 20% a 33% dos pacientes apresentam sintomas atípicos. O diagnóstico é mais difícil nas crianças, nos idosos e nas mulheres em idade fértil. Os principais métodos de imagem para sua avaliação são a ultra-sonografia e a tomografia computadorizada. Os objetivos deste trabalho são: descrever a fisiopatologia da doença, comentar os principais aspectos técnicos da tomografia computadorizada, demonstrar e ilustrar os achados tomográficos e citar os principais diagnósticos diferenciais.Acute appendicitis is the most important cause of abdominal pain requiring surgical intervention in the Western world. The early diagnosis of this disease is of paramount relevance for minimizing its morbidity. Imaging methods have represented a huge progress in the diagnosis of this entity, which used to be based essentially on clinical history, physical examination and laboratory tests results, considering that 20% to 33% of patients present with atypical symptoms. Diagnostic difficulty is higher in children, the elderly, and women in childbearing age. The main imaging methods for evaluation of acute appendicitis are ultrasound and computed tomography. The present study is aimed at describing the disease physiopathology, commenting main computed tomography technical aspects, demonstrating and illustrating tomographic findings, and describing main differential diagnoses.

  10. Cálculo de la transmisión paralela helicoidal de la caja multiplicadora de una turbina eólica

    Directory of Open Access Journals (Sweden)

    César Alberto Chagoyén-Méndez

    2014-01-01

    Full Text Available La caja multiplicadora de una turbina eólica es el componente de mayor complejidad mecánica y es la responsable de la mayoría de la pérdida de tiempo operacional de la turbina y del incremento de los costos. La misma no alcanza una vida proyectada de 20 años. Todos los estudios hasta el momento indican que estas fallas surgen desde el proceso de diseño. Este trabajo tuvo como objetivo demostrar algunas de las insuficiencias de las normas actuales de diseño de las cajas multiplicadoras de las turbinas eólicas, a través de la realización de una comparación de los resultados del cálculo de la transmisión paralela helicoidal de una turbina eólica de 2,5 MW, realizados por tres vías: con las normas ISO 6336:2006 Método B y AGMA 2101-D04 ( Metric Edition y mediante simulación numérica. De este análisis resulta que no existen problemas de resistencia ni de rigidez en ambas transmisiones, sin embargo la diferencia entre estos tres métodos de cálculo es considerable.

  11. Efeitos da anemia materna na cardiotocografia computadorizada e perfil biofísico fetal Effects of maternal anemia on computerized cardiotocography and fetal biophysical profile

    Directory of Open Access Journals (Sweden)

    Roseli Mieko Yamamoto Nomura

    2009-12-01

    Full Text Available OBJETIVOS: avaliar a influência dos níveis de hemoglobina (Hb materna nos padrões da frequência cardíaca fetal (FCF e no perfil biofísico fetal (PBF em gestações a termo. MÉTODOS: gestantes portadoras de anemia (Hb11,0 g/dL. Foram excluídos casos com anomalias ou restrição do crescimento fetal. A avaliação da FCF foi realizada pela cardiotocografia computadorizada (Sistema8002-Sonicaid e análise do traçado com 30 minutos de exame. O PBF foi realizado em todas as pacientes. Foram utilizados os testes t de Student, teste do χ2 e teste exato de Fisher. O nível de significância utilizado foi de 0,05. RESULTADOS: A média da Hb materna no grupo com anemia (n=18 foi de 9,4 g/dL (DP=1,4 g/dL e no Grupo Controle 12,4 g/dL (DP=1,3 g/dL. Quanto aos parâmetros da cardiotocografia, não foi constatada diferença significativa nas médias entre os grupos com anemia e controle, respectivamente: FCF basal (131,3 bpm versus 133,7 bpm, p=0,5, acelerações da FCF > 10 bpm (7,9 versus. 8,2, p=0,866, acelerações da FCF > 15 bpm (5,2 versus 5,4, p=0,9, episódios de alta variação da FCF (17,1 versus 15,5 min, p=0,5, episódios de baixa variação da FCF (4,4 versus 3,6 min, p=0,6, e variação de curto prazo (10,5 versus 10,9 ms, p=0,5. Em ambos os grupos, todas as pacientes apresentaram PBF normal. CONCLUSÕES: este estudo sugere que a anemia materna leve ou moderada, sem outras comorbidades maternas ou fetais, não se associa a anormalidades nos parâmetros do perfil biofísico fetal e da FCF analisada pela cardiotocografia computadorizada.PURPOSES: to evaluate the influence of maternal hemoglobin (Hb levels in the patterns of fetal heart rate (FHR and in the fetal biophysical profile (FBP in term gestations. METHODS: pregnant women with anemia (Hb11,0 g/dL. Cases of anomalies or fetal growing restrictions were excluded. The FHR evaluation was performed by computerized cardiotocography (8002 System-Sonicaid, and by record analysis during

  12. SEM probe of IC radiation sensitivity

    Science.gov (United States)

    Gauthier, M. K.; Stanley, A. G.

    1979-01-01

    Scanning Electron Microscope (SEM) used to irradiate single integrated circuit (IC) subcomponent to test for radiation sensitivity can localize area of IC less than .03 by .03 mm for determination of exact location of radiation sensitive section.

  13. La agresividad y las capacidades del área de matemática en estudiantes del tercero de secundaria de la institución educativa Saco Oliveros – Helicoidal Ate 2011

    OpenAIRE

    Espinoza Chaca, Carmen Ascenciona; Melissa Wendy Zárate Murga, Melissa Wendy

    2016-01-01

    La presente investigación tiene como objetivo determinar la relación que existe entre la agresividad y las capacidades del área de matemática en estudiantes del tercero de secundaria de la institución educativa Saco Oliveros – Helicoidal Ate 2011 . Para la investigación se utilizó un cuestionario para determinar el nivel de autoestima y actas de evaluación aprendizaje de los estudiantes. La muestra estuvo constituida por 109 estudiantes. Se realizaron pruebas estadísticas y ...

  14. Análise por tomografia computadorizada do enxerto autógeno na cirurgia de "sinus lift" Computed tomography evaluation of autogenous graft in sinus lift surgery

    Directory of Open Access Journals (Sweden)

    Sérgio Aron Ajzen

    2005-02-01

    Full Text Available OBJETIVO: Quantificar a formação óssea nos enxertos com e sem plasma rico em plaquetas, obtido pelos métodos de centrifugação e aférese, comparando os três tipos de enxertos realizados por meio de análise tomográfica. MATERIAIS E MÉTODOS: Este estudo prospectivo, duplo cego, utilizou uma amostra composta de 34 pacientes adultos, de ambos os sexos, com idade média de 48 anos e 8 meses, portadores de pneumatização unilateral ou bilateral dos seios maxilares, que necessitavam de enxertos ósseos, com a finalidade de melhorar as condições locais para a colocação dos implantes dentários. Todos os pacientes realizaram tomografia computadorizada antes da cirurgia. Foram operados 53 seios maxilares, divididos em três grupos: enxerto de plasma rico em plaquetas obtido pelos métodos de aférese, centrifugação e enxerto apenas de osso autógeno. Após seis meses do procedimento cirúrgico foram realizados novos exames de imagem. RESULTADOS: Pela avaliação tomográfica, houve crescimento em altura e em largura nos três grupos quando foram comparados os momentos inicial e final, entretanto, não houve diferença estatística para a altura e para a largura. CONCLUSÃO: Evidências clínicas demonstram a eficácia dos enxertos autógenos, principalmente os associados a fatores indutores de crescimento ósseo, como o plasma rico em plaquetas, recuperando o arcabouço maxilofacial, necessário para a reconstrução protética e funcional por meio de implantes dentários.OBJECTIVE: To quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from aphaeresis or centrifugation using computed tomography. MATERIALS AND METHODS: This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months, with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental

  15. Advanced metrology by offline SEM data processing

    Science.gov (United States)

    Lakcher, Amine; Schneider, Loïc.; Le-Gratiet, Bertrand; Ducoté, Julien; Farys, Vincent; Besacier, Maxime

    2017-06-01

    Today's technology nodes contain more and more complex designs bringing increasing challenges to chip manufacturing process steps. It is necessary to have an efficient metrology to assess process variability of these complex patterns and thus extract relevant data to generate process aware design rules and to improve OPC models. Today process variability is mostly addressed through the analysis of in-line monitoring features which are often designed to support robust measurements and as a consequence are not always very representative of critical design rules. CD-SEM is the main CD metrology technique used in chip manufacturing process but it is challenged when it comes to measure metrics like tip to tip, tip to line, areas or necking in high quantity and with robustness. CD-SEM images contain a lot of information that is not always used in metrology. Suppliers have provided tools that allow engineers to extract the SEM contours of their features and to convert them into a GDS. Contours can be seen as the signature of the shape as it contains all the dimensional data. Thus the methodology is to use the CD-SEM to take high quality images then generate SEM contours and create a data base out of them. Contours are used to feed an offline metrology tool that will process them to extract different metrics. It was shown in two previous papers that it is possible to perform complex measurements on hotspots at different process steps (lithography, etch, copper CMP) by using SEM contours with an in-house offline metrology tool. In the current paper, the methodology presented previously will be expanded to improve its robustness and combined with the use of phylogeny to classify the SEM images according to their geometrical proximities.

  16. LINFOMAS PULMONARES: CORRELAÇÃO DA TOMOGRAFIA COMPUTADORIZADA DE ALTA RESOLUÇÃO COM A ANATOMOPATOLOGIA

    Directory of Open Access Journals (Sweden)

    Marchiori Edson

    2002-01-01

    Full Text Available Neste trabalho são descritos os aspectos tomográficos de alta resolução dos linfomas pulmonares e feita correlação com os achados anatomopatológicos. Com este objetivo, foram revisados as tomografias computadorizadas de alta resolução do tórax e os dados histopatológicos de dez pacientes com diagnóstico confirmado de linfoma não-Hodgkin ou de doença de Hodgkin. Os resultados obtidos foram confrontados com os descritos na literatura. Os achados radiológicos mais comumente vistos neste estudo foram as consolidações parenquimatosas, localizadas, com broncogramas aéreos de permeio (n = 8. Em menor freqüência, foram encontrados múltiplos nódulos parenquimatosos (n = 4, espessamento peribroncovascular (n = 3 e opacidades em vidro fosco (n = 2. Na correlação com a anatomia patológica, as consolidações corresponderam a preenchimento alveolar por células neoplásicas, o espessamento peribroncovascular se deveu a infiltração das bainhas peribroncovasculares por células linfomatosas e a atenuação em vidro fosco se associou com infiltração dos septos alveolares por tais células.

  17. Computerized tomography findings in Fahr's syndrome Achados da tomografia computadorizada na síndrome de Fahr

    Directory of Open Access Journals (Sweden)

    Andréia V. Faria

    2004-09-01

    Full Text Available We analyzed computerized tomography (CT findings in six patients with Fahr's syndrome. They presented calcifications in basal ganglia, dentate nucleus, subcortical region and semioval center, due to alteration in calcium metabolism or due to senile relative hypoxemic state. The image pattern was not strictly related with etiology, although some differences in dystrophic senile calcifications (the only one present in semioval center and absent in subcortical region. CT is an easy exam, has maximum sensitivity and allows diagnosis, contributing to early treatment of many etiologies of Fahr's syndrome.Analisamos os achados de tomografia computadorizada (TC de seis pacientes com síndrome de Fahr. Eles apresentaram calcificações nos gânglios da base, núcleo denteado, região subcortical e centro semi-oval, devidas a distúrbios no metabolismo do cálcio ou a estado de hipóxia relativa, por senilidade. O padrão de imagem não apresenta relação clara com a etiologia, apesar de algumas diferenças no caso das calcificações distróficas senis (as únicas presentes nos centros semi-ovais e ausentes na região subcortical. TC é um exame de fácil realização, máxima sensibilidade e permite o diagnóstico, contribuindo para o tratamento precoce de muitas das etiologias da síndrome de Fahr.

  18. Oxford CyberSEM: remote microscopy

    International Nuclear Information System (INIS)

    Rahman, M; Kirkland, A; Cockayne, D; Meyer, R

    2008-01-01

    The Internet has enabled researchers to communicate over vast geographical distances, sharing ideas and documents. e-Science, underpinned by Grid and Web Services, has enabled electronic communications to the next level where, in addition to document sharing, researchers can increasingly control high precision scientific instruments over the network. The Oxford CyberSEM project developed a simple Java applet via which samples placed in a JEOL 5510LV Scanning Electron Microscope (SEM) can be manipulated and examined collaboratively over the Internet. Designed with schoolchildren in mind, CyberSEM does not require any additional hardware or software other than a generic Java-enabled web browser. This paper reflects on both the technical and social challenges in designing real-time systems for controlling scientific equipments in collaborative environments. Furthermore, it proposes potential deployment beyond the classroom setting.

  19. Partial Least Squares Strukturgleichungsmodellierung (PLS-SEM)

    DEFF Research Database (Denmark)

    Hair, Joseph F.; Hult, G. Tomas M.; Ringle, Christian M.

    (PLS-SEM) hat sich in der wirtschafts- und sozialwissenschaftlichen Forschung als geeignetes Verfahren zur Schätzung von Kausalmodellen behauptet. Dank der Anwenderfreundlichkeit des Verfahrens und der vorhandenen Software ist es inzwischen auch in der Praxis etabliert. Dieses Buch liefert eine...... anwendungsorientierte Einführung in die PLS-SEM. Der Fokus liegt auf den Grundlagen des Verfahrens und deren praktischer Umsetzung mit Hilfe der SmartPLS-Software. Das Konzept des Buches setzt dabei auf einfache Erläuterungen statistischer Ansätze und die anschauliche Darstellung zahlreicher Anwendungsbeispiele anhand...... einer einheitlichen Fallstudie. Viele Grafiken, Tabellen und Illustrationen erleichtern das Verständnis der PLS-SEM. Zudem werden dem Leser herunterladbare Datensätze, Aufgaben und weitere Fachartikel zur Vertiefung angeboten. Damit eignet sich das Buch hervorragend für Studierende, Forscher und...

  20. FIB-SEM tomography in biology.

    Science.gov (United States)

    Kizilyaprak, Caroline; Bittermann, Anne Greet; Daraspe, Jean; Humbel, Bruno M

    2014-01-01

    Three-dimensional information is much easier to understand than a set of two-dimensional images. Therefore a layman is thrilled by the pseudo-3D image taken in a scanning electron microscope (SEM) while, when seeing a transmission electron micrograph, his imagination is challenged. First approaches to gain insight in the third dimension were to make serial microtome sections of a region of interest (ROI) and then building a model of the object. Serial microtome sectioning is a tedious and skill-demanding work and therefore seldom done. In the last two decades with the increase of computer power, sophisticated display options, and the development of new instruments, an SEM with a built-in microtome as well as a focused ion beam scanning electron microscope (FIB-SEM), serial sectioning, and 3D analysis has become far easier and faster.Due to the relief like topology of the microtome trimmed block face of resin-embedded tissue, the ROI can be searched in the secondary electron mode, and at the selected spot, the ROI is prepared with the ion beam for 3D analysis. For FIB-SEM tomography, a thin slice is removed with the ion beam and the newly exposed face is imaged with the electron beam, usually by recording the backscattered electrons. The process, also called "slice and view," is repeated until the desired volume is imaged.As FIB-SEM allows 3D imaging of biological fine structure at high resolution of only small volumes, it is crucial to perform slice and view at carefully selected spots. Finding the region of interest is therefore a prerequisite for meaningful imaging. Thin layer plastification of biofilms offers direct access to the original sample surface and allows the selection of an ROI for site-specific FIB-SEM tomography just by its pronounced topographic features.

  1. Avaliação, por meio de microtomografia computadorizada, da anatomia interna e externa de primeiros pré-molares superiores

    OpenAIRE

    Amanda Buosi de Biagi

    2014-01-01

    O objetivo do presente estudo foi avaliar a anatomia do sistema de canais radiculares (SCR) de 72 primeiros pré-molares superiores (32 unirradiculares, 30 birradiculares com sulcos e 10 trirradiculares), por meio de microtomografia computadorizada (μCT). As amostras foram escaneadas no microtomógrafo SkyScan 1174 v2, e as imagens geradas foram reconstruídas para análise dos parâmetros bidimensionais (número, área, circularidade , diâmetro maior e menor, fator de forma) a 1, 2, 3 mm d...

  2. Search Engine Marketing (SEM: Financial & Competitive Advantages of an Effective Hotel SEM Strategy

    Directory of Open Access Journals (Sweden)

    Leora Halpern Lanz

    2015-05-01

    Full Text Available Search Engine Marketing and Optimization (SEO, SEM are keystones of a hotels marketing strategy, in fact research shows that 90% of travelers start their vacation planning with a Google search. Learn five strategies that can enhance a hotels SEO and SEM strategies to boost bookings.

  3. Search Engine Marketing (SEM): Financial & Competitive Advantages of an Effective Hotel SEM Strategy

    OpenAIRE

    Leora Halpern Lanz

    2015-01-01

    Search Engine Marketing and Optimization (SEO, SEM) are keystones of a hotels marketing strategy, in fact research shows that 90% of travelers start their vacation planning with a Google search. Learn five strategies that can enhance a hotels SEO and SEM strategies to boost bookings.

  4. Does Sexually Explicit Media (SEM) Affect Me?

    DEFF Research Database (Denmark)

    Hald, Gert Martin; Træen, Bente; Noor, Syed W

    2015-01-01

    and understanding of one’s sexual orientation.First-person effects refer to self-perceived and self-reported effects of SEM consumptionas experienced by the consumer. In addition, the study examined and provided athorough validation of the psychometric properties of the seven-item PornographyConsumption Effect...

  5. SEM: A user's manual for materials science

    International Nuclear Information System (INIS)

    Gabriel, B.L.

    1985-01-01

    This book provides a reference of techniques used by the metallurgical microscopist. It contains an introduction to the instrumentation and methods of scanning electron microscopy with historical as well as state-of-the-art methodologies. Topics covered include: SEM instrumentation, photography, energy dispersive spectroscopy, introduction to sample preparation, polished samples, fracture surfaces, replicas and thin films

  6. Building a SEM Analytics Reporting Portfolio

    Science.gov (United States)

    Goff, Jay W.; Williams, Brian G.; Kilgore, Wendy

    2016-01-01

    Effective strategic enrollment management (SEM) efforts require vast amounts of internal and external data to ensure that meaningful reporting and analysis systems can assist managers in decision making. A wide range of information is integral for leading effective and efficient student recruitment and retention programs. This article is designed…

  7. Tomografia computadorizada como método auxiliar no diagnóstico e tratamento de lesões intra-ósseas: caso clínico de odontoma composto = Computed tomography as auxiliary method in the diagnostic and treatment of intra-osseos lesions: a case of compound odontoma

    Directory of Open Access Journals (Sweden)

    Paiano, Grasiela Antunes

    2006-01-01

    Full Text Available O advento da tomografia computadorizada (TC possibilita de visualização tridimensional, favorece o diagnóstico e proporcionando um tratamento mais preciso em virtude da localização exata da lesão e análise da proximidade com as estruturas anatômicas vitais relacionadas. Contudo o tratamento de lesões ósseas se torna mais segura, reduzindo o risco de lesão a dentes adjacentes e nervos. O Odontoma é considerado o tumor odontogênico que mais comumente acomete os ossos maxilares. A variante composta deste tumor apresenta a característica de muitas estruturas semelhantes a dentes envolvidas por um halo radiolúcido e grande freqüência na região anterior da maxila, porém o diagnóstico deste tumor nas demais localizações dos maxilares é pouco freqüente. Apresenta normalmente crescimento limitado e expande as corticais ósseas, porém sem tendência à recidiva. O tratamento do odontoma consiste na sua excisão cirúrgica. Os autores pretendem relatar a utilização da TC como método auxiliar no diagnóstico e tratamento de um caso de exérese de um odontoma composto na região anterior da mandíbula

  8. Bases de Datos Semánticas

    Directory of Open Access Journals (Sweden)

    Irving Caro Fierros

    2016-12-01

    Full Text Available En 1992, cuando Tim Berners-Lee dio a conocer la primera  versión  de  la  Web,  su  visión  a  futuro  era  incorporar metadatos  con  información  semántica  en  las  páginas  Web.  Es precisamente   a   principios   de   este   siglo   que   inicia   el   auge repentino  de  la  Web  semántica  en  el  ambiente  académico  e Internet. El modelo de datos semántico se define como un modelo conceptual que permite definir el significado de los datos a través de  sus  relaciones  con  otros.  En  este  sentido,  el  formato  de representación  de  los  datos  es  fundamental  para  proporcionar información de carácter semántico. La tecnología enfocada en las bases de datos semánticas se encuentra actualmente en un punto de  inflexión,  al  pasar  del  ámbito  académico  y  de  investigación  a ser una opción comercial completa. En este artículo se realiza un análisis  del  concepto  de  base  de  datos  semántica.  También  se presenta  un  caso  de  estudio  donde  se  ejemplifican  operaciones básicas  que  involucran  la  gestión  de  la  información  almacenada en este tipo de base de datos.

  9. SEM investigation of heart tissue samples

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, R; Amoroso, M [Physics Department, University of the West Indies, St. Augustine, Trinidad and Tobago, West Indies (Trinidad and Tobago)

    2010-07-01

    We used the scanning electron microscope to examine the cardiac tissue of a cow (Bos taurus), a pig (Sus scrofa), and a human (Homo sapiens). 1mm{sup 3} blocks of left ventricular tissue were prepared for SEM scanning by fixing in 96% ethanol followed by critical point drying (cryofixation), then sputter-coating with gold. The typical ridged structure of the myofibrils was observed for all the species. In addition crystal like structures were found in one of the samples of the heart tissue of the pig. These structures were investigated further using an EDVAC x-ray analysis attachment to the SEM. Elemental x-ray analysis showed highest peaks occurred for gold, followed by carbon, oxygen, magnesium and potassium. As the samples were coated with gold for conductivity, this highest peak is expected. Much lower peaks at carbon, oxygen, magnesium and potassium suggest that a cystallized salt such as a carbonate was present in the tissue before sacrifice.

  10. SEM investigation of heart tissue samples

    International Nuclear Information System (INIS)

    Saunders, R; Amoroso, M

    2010-01-01

    We used the scanning electron microscope to examine the cardiac tissue of a cow (Bos taurus), a pig (Sus scrofa), and a human (Homo sapiens). 1mm 3 blocks of left ventricular tissue were prepared for SEM scanning by fixing in 96% ethanol followed by critical point drying (cryofixation), then sputter-coating with gold. The typical ridged structure of the myofibrils was observed for all the species. In addition crystal like structures were found in one of the samples of the heart tissue of the pig. These structures were investigated further using an EDVAC x-ray analysis attachment to the SEM. Elemental x-ray analysis showed highest peaks occurred for gold, followed by carbon, oxygen, magnesium and potassium. As the samples were coated with gold for conductivity, this highest peak is expected. Much lower peaks at carbon, oxygen, magnesium and potassium suggest that a cystallized salt such as a carbonate was present in the tissue before sacrifice.

  11. Viewing Integrated-Circuit Interconnections By SEM

    Science.gov (United States)

    Lawton, Russel A.; Gauldin, Robert E.; Ruiz, Ronald P.

    1990-01-01

    Back-scattering of energetic electrons reveals hidden metal layers. Experiment shows that with suitable operating adjustments, scanning electron microscopy (SEM) used to look for defects in aluminum interconnections in integrated circuits. Enables monitoring, in situ, of changes in defects caused by changes in temperature. Gives truer picture of defects, as etching can change stress field of metal-and-passivation pattern, causing changes in defects.

  12. Structuring Consumer Preferences with the SEM Method

    OpenAIRE

    Rosa, Franco

    2002-01-01

    Structuring preferences has been developed with econometric models using functional flexible parametric form and the exploring the perceptions about expressed and latent needs using different multivariate approaches. Purpose of this research is to explore the demand for a new drink using the mean-end chain (MEC) theory and multivariate SEM procedure. The first part is dedicated to description of specialty foods for their capacity to create new niche markets. The MEC theory is introduced to ex...

  13. Tomografia computadorizada e ressonância magnética nos oligodendrogliomas: correlação clínica e patológica

    Directory of Open Access Journals (Sweden)

    Simão Marcelo Novelino

    2001-01-01

    Full Text Available Oligodendrogliomas são neoplasias do tecido neuroepitelial glial originárias de oligodendrócitos. São tumores infreqüentes, responsáveis por cerca de 4% a 7% das neoplasias primárias do cérebro, predominantemente supratentoriais. O presente trabalho consistiu na avaliação dos achados de imagem pré-operatória em tomografia computadorizada e ressonância magnética e correlação clínica e patológica, levando-se em consideração a presença de tumores puros ou mistos, com componente astrocitário e o seu grau de anaplasia. O aspecto mais freqüente foi o de lesão hipodensa na tomografia computadorizada ou com hipossinal em T1 e hipersinal em T2 na ressonância magnética, podendo ter componente cístico, com pouco edema ao redor, apresentando calcificações, quase sempre grosseiras, em dois terços dos casos. Reforço após contraste ocorre em 80% dos casos, na maioria discreto.

  14. Bases de Datos Semánticas

    OpenAIRE

    Irving Caro Fierros; Víctor Hugo Menéndez Domínguez; María Enriqueta Castellanos Bolaños

    2016-01-01

    En 1992, cuando Tim Berners-Lee dio a conocer la primera  versión  de  la  Web,  su  visión  a  futuro  era  incorporar metadatos  con  información  semántica  en  las  páginas  Web.  Es precisamente   a   principios   de   este   siglo   que   inicia   el   auge repentino  de  la  Web  semántica  en  el  ambiente  académico  e Internet. El modelo de datos semántico se define como un modelo conceptual que permite definir el significado de los datos a través de  sus  relaciones  con  otros.  E...

  15. Characterization of Yeast Biofilm by Cryo-SEM and FIB-SEM

    Czech Academy of Sciences Publication Activity Database

    Hrubanová, Kamila; Nebesářová, Jana; Růžička, F.; Dluhoš, J.; Krzyžánek, Vladislav

    2013-01-01

    Roč. 19, S2 (2013), s. 226-227 ISSN 1431-9276 R&D Projects: GA MŠk EE.2.3.20.0103; GA TA ČR TE01020118; GA ČR GAP205/11/1687 Institutional support: RVO:68081731 ; RVO:60077344 Keywords : yeast biofilm * cryo-SEM * FIB-SEM Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.757, year: 2013

  16. O ciberativismo sem bússola

    Directory of Open Access Journals (Sweden)

    Francisco Rüdiger

    2014-07-01

    Full Text Available Questiona-se no texto se uma abordagem que, no essencial, relata a trajetória do chamado ciberativismo de acordo com seus próprios termos se justifica academicamente ou, em vez disso, se mantém prisioneira de uma mitologia que o fenômeno, em si mesmo, já construiu e, por isso, autoriza seus sujeitos a dispensarem sem prejuízo eventual contribuição de origem universitária.

  17. Afasia global sem hemiparesia: relato de caso

    OpenAIRE

    SILVA,MARCUS TULIUS TEIXEIRA DA; CAVALCANTI,JOSÉ LUÍS DE SÁ; MOREIRA,DENISE MADEIRA

    2000-01-01

    Afasia global geralmente é acompanhada por hemiparesia direita devido à extensão da lesão subjacente. Recentemente têm sido registrados na literatura casos em que tal síndrome ou não se acompanha do déficit motor ou este é apenas transitório, sendo esta condição conhecida como afasia global sem hemiparesia (AGSH). Relatamos caso de AGSH devido a infarto cerebral embólico cardiogênico, corroborando a tese de que esta condição pode ter valor preditivo para o diagnóstico de infartos embólicos....

  18. Tomografia computadorizada no diagnóstico da otosclerose retrofenestral Computed tomography in the diagnosis of retrofenestral otosclerosis

    Directory of Open Access Journals (Sweden)

    Andy de Oliveira Vicente

    2004-01-01

    Full Text Available OBJETIVO: Identificar os principais achados tomográficos da otosclerose retrofenestral. MÉTODO: Estudo prospectivo multicêntrico com tomografia computadorizada (TC de ossos temporais em 54 pacientes com diagnóstico clínico e cirúrgico de otosclerose. Foi realizada uma análise tomográfica, em que foi avaliada a utilidade da TC no diagnóstico radiológico da otosclerose retrofenestral, sendo verificados os principais sítios de lesões dessa doença. Foram incluídos neste estudo 22 pacientes submetidos à TC de ossos temporais para investigação de outras afecções otológicas, que constituíram o grupo controle. RESULTADOS: Os achados tomográficos foram bilaterais na maioria dos casos e o foco retrofenestral mais prevalente foi o foco pericoclear. CONCLUSÕES: A TC monstrou-se útil na identificação dos focos retrofenestrais. A evidência tomográfica desses focos juntamente com o envolvimento endosteal da cóclea podem sugerir uma maior atividade da doença.AIM: To identify the main tomographic findings of retrofenestral otosclerosis. METHODS: A prospective and multicentric study using computed tomography (CT of the temporal bone in 54 patients with a clinical and surgical diagnosis of otosclerosis. A tomographic analysis has been performed to evaluate the utility of CT scans in diagnosing retrofenestral otosclerosis, verifying the sites of predilection for otosclerotic lesions. In this study, 22 patients undergone CT scans of temporal bones have been included in order to investigate other otologic diseases and have constituted the control group. RESULTS: The tomographic findings were mostly bilateral and the retrofenestral focus more prevalent was the pericochlear focus. CONCLUSIONS: The CT scan was useful in the identification of the retrofenestral focuses. The evidence of this focuses and the presence of the endosteal involvement of the cochlea can suggest a higher activity of the disease.

  19. El semáforo loco

    OpenAIRE

    González de Zachrisson, Hena

    2016-01-01

    El semáforo lo acababan de instalar en Vía Brasil y Calle 50 y estaba contento de poder mantener el orden del tránsito en tan importante calle. Sin embargo, pronto descubrió que su tarea no era fácil. Su territorio estaba atestado de muchachos que vendían frutas y vegetales y para escapar de ellos, los conductores hacían regatas para cruzar la calle antes de que la luz cambiara a rojo. —Todo a un dólar! —gritaban los chicos mostrando su bolsa de guineo, naranja, melón, maíz, papaya, c...

  20. In-situ SEM electrochemistry and radiolysis

    DEFF Research Database (Denmark)

    Møller-Nilsen, Rolf Erling Robberstad; Norby, Poul

    are backscattered and an image is reconstructed by the microscope. But the high energy electrons are a form of ionising radiation which can significantly affect the chemistry in liquid experiments. Ionising radiation can split water, produce radicals, reduce dissolved metal ions to metal particles, and more...... experiments. During the course of these studies it has also been possible to improve on the EC-SEM system. This has resulted in pyrolysed carbon electrodes, which offer the benefit of stability at 0.75 V higher potentials than traditional gold thin-film electrodes. With the quantitative insight...... microelectrodes on the windows to enable studies of electrohcemical processes. In this way it is possible to perform in-situ electrochemical experiments such as electroplating and charge and discharge analysis of battery electrodes. In a typical liquid cell, electrons are accelerated to sufficiently high energies...

  1. The luminal surface of thyroid cysts in SEM

    DEFF Research Database (Denmark)

    Zelander, T; Kirkeby, S

    1978-01-01

    Four of the five kinds of cells constituting the walls of thyroid cysts can be identified in the SEM. These are cuboidal cells, mucous cells, cells with large granules and ciliated cells. A correlation between SEM and TEM observations is attempted.......Four of the five kinds of cells constituting the walls of thyroid cysts can be identified in the SEM. These are cuboidal cells, mucous cells, cells with large granules and ciliated cells. A correlation between SEM and TEM observations is attempted....

  2. Measuring topographies from conventional SEM acquisitions.

    Science.gov (United States)

    Shi, Qiwei; Roux, Stéphane; Latourte, Félix; Hild, François; Loisnard, Dominique; Brynaert, Nicolas

    2018-04-27

    The present study extends the stereoscopic imaging principle for estimating the surface topography to two orientations, namely, normal to the electron beam axis and inclined at 70° as suited for EBSD analyses. In spite of the large angle difference, it is shown that the topography can be accurately determined using regularized global Digital Image Correlation. The surface topography is compared to another estimate issued from a 3D FIB-SEM procedure where the sample surface is first covered by a Pt layer, and its initial topography is progressively revealed from successive FIB-milling. These two methods are successfully compared on a 6% strained steel specimen in an in situ mechanical test. This analysis is supplemented by a third approach estimating the change of topography from crystal rotations as measured from successive EBSD images. This last technique ignores plastic deformation, and thus only holds in an elastic regime. For the studied example, despite the large plastic flow, it is shown that crystal rotation already accounts for a significant part of the deformation-induced topography. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Analysis list: sem-4 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available sem-4 Larvae + ce10 http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/target/sem-4.1....tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/target/sem-4.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/target/sem...-4.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/colo/sem-4.Larvae.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/colo/Larvae.gml ...

  4. Stirling Energy Module (SEM) as Micro-CHP; Stirling Energy Module (SEM) als Mini-BHKW

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, A.

    2006-07-01

    Since many years, a lot of effort is being put into the development of combined heat and power units (CHP) for the decentralised production of electric power. For long time, the main focus was on fuel cells. In the meantime, the Stirling technology, which is based upon classical mechanical engineering and innovative technical concepts, proceeded in its development as well. The following article describes the technology and the actual state of the development of the Stirling Energy Module (SEM) for the application as Micro-CHP in one-family-houses. SEM is based on a free-piston engine with a linear power generator, producing electric power while heating. The Stirling engine is planned the be introduced into the market as a replacement for the conventional heating systems within a couple of years. (author)

  5. Densidade de um planossolo sob sistemas de cultivo avaliada por meio da tomografia computadorizada de raios gama Bulk density of an alfisol under cultivation systems in a long-term experiment evaluated with gamma ray computed tomography

    Directory of Open Access Journals (Sweden)

    Adilson Luís Bamberg

    2009-10-01

    Full Text Available A sustentabilidade do arroz (Oryza sativa L. irrigado em solos de várzea está alicerçada na utilização da rotação e sucessão de culturas, fundamentais para o controle do arroz-vermelho e preto. Os reflexos sobre os atributos dos solos de várzea merecem estudos em especial sobre a compactação do solo. O objetivo deste trabalho foi identificar camadas compactadas em Planossolo submetido a diferentes sistemas de cultivo e preparo, avaliando-se a densidade do solo (Ds pela Tomografia Computadorizada de Raios Gama (TC. A análise foi realizada em um experimento de longa duração, conduzido de 1985 a 2004, na Estação Experimental da Embrapa Clima Temperado, Capão do Leão, RS, num delineamento experimental em blocos ao acaso, com sete tratamentos, cada um com quatro repetições (T1 - um ano de arroz com preparo convencional do solo seguido de dois anos de pousio; T2 - cultivo contínuo de arroz com preparo convencional do solo; T4 - rotação de arroz e soja (Glycine max L. com preparo convencional do solo; T5 - rotação de arroz, soja e milho (Zea maiz L. em preparo convencional do solo; T6 - plantio direto de arroz no verão em sucessão do azevém (Lolium multiflorum L. no inverno; T7 - rotação de arroz sob plantio direto e soja sob preparo convencional do solo; T8 - testemunha: solo sem cultivo. A Tomografia Computadorizada de Raios Gama permitiu detectar que o plantio direto de arroz no verão em sucessão do azevém no inverno não resultou na formação de camadas compactadas; a utilização de dois anos de pousio, no sistema de produção de arroz irrigado, não foi suficiente para evitar a formação de uma camada superficial compactada; e a rotação de arroz, soja e milho com preparo convencional do solo apresentou duas camadas compactadas (0,0 a 1,5 cm e 11 a 14 cm, indicando que essas podem limitar a produção agrícola nesse sistema de produção em Planossolos.The sustainability of irrigated rice (Oryza sativa L. in

  6. Canticum Novum: música sem palavras e palavras sem som no pensamento de Santo Agostinho

    Directory of Open Access Journals (Sweden)

    Lorenzo Mammì

    2000-04-01

    Full Text Available NO De Magistro, Santo Agostinho coloca a reza e o canto numa posição similar, à margem das funções imediatamente comunicativas da linguagem. A reflexão agostiniana sobre a reza se baseia nos hábitos cristãos da leitura, da oração e da meditação silenciosas. Há sobre o canto, na prática igualmente inovadora do jubilus, melodia sem palavra destinada aos momentos mais intensos e gaudiosos da liturgia. A oração silenciosa e o jubilus são temas recorrentes da literatura patrística, mas Agostinho os aborda de maneira original, desenhando, a partir das palavras sem som da oração e do som sem palavra do jubilus, o perfil de um discurso interior, que não se destina aos homens, mas a Deus.IN HIS De Magistro Saint Augustine places prayer and song on a similar level, alongside the language immediately communicative functions. His considerations on prayer are grounded on the Christian habits of silent reading, prayer and meditation; those on song, on the equally innovating practice called jubilus, which is melody without words designed for the intensest and most joyous liturgical moments. Silent prayer and jubilus are recurring topics in patristic literature, but Augustine deals with them in an original way, drawing from the soundless words of prayer and the wordless sound of jubilus an inner discourse, addressed not to men but to God.

  7. A influência postural do salto alto em mulheres adultas: análise por biofotogrametria computadorizada Postural influence of high heels among adult women: analysis by computerized photogrammetry

    Directory of Open Access Journals (Sweden)

    DH Iunes

    2008-12-01

    Full Text Available INTRODUÇÃO: Em nossa sociedade, temos observado uma oferta cada vez maior de modelos, cores, estilos, altura e diversos tipos de salto. OBJETIVO: Avaliar se o uso de calçados de salto alto influencia nas alterações posturais com base em um conjunto de variáveis mensuradas por meio da fotogrametria computadorizada. MÉTODOS: Vinte indivíduos que utilizam salto alto com freqüência (grupo 1 e 20 indivíduos que utilizam salto alto esporadicamente (grupo 2 foram fotografados no plano frontal anterior e sagital em três momentos: a sem utilização de calçado, b utilizando salto agulha e c utilizando salto plataforma, sendo estas fotografias aleatorizadas e analisadas por um experimentador cego por meio da fotogrametria. A análise estatística foi realizada a partir da análise de variância em esquema fatorial 2x3, ou seja, comparando-se a freqüência do uso de salto com o tipo de calçado, com 5% de significância. RESULTADOS: Apenas o ângulo protrusão da cabeça apresentou diferença quando comparados grupo 1 e 2 (pINTRODUCTION: In our society, it is observed an increasing number of models, colors, styles, heights and types of high heels. OBJECTIVE: To evaluate whether the use of high heel shoes results in postural changes, based on a set of variables measured through computerized photogrammetry. METHODS: Twenty individuals who often used high heels (group 1 and 20 individuals who only used high heels sporadically (group 2 were photographed in the frontal and sagittal planes at three conditions: a without using footwear; b using stiletto heels; and c using high platform heels. These photographs were randomized and analyzed by a blinded examiner, by means of photogrammetry. Statistical analysis was performed, using a 2x3 factorial analysis of variance to compare the frequency of high heel use with the type of shoe, at the 5% significance level. RESULTS: Only the head protrusion angle showed a difference between groups 1 and 2 (p<0

  8. Validation of computed tomography protocols for simulated mandibular lesions: a comparison study Validação de protocolos de tomografia computadorizada para lesões simuladas em mandíbula: estudo comparativo

    Directory of Open Access Journals (Sweden)

    Andréia Perrella

    2007-06-01

    Full Text Available Computed tomography is the choice technique to assess oral and maxillofacial osseous lesions because it provides hard and soft tissues visualization in one examination without superimposition of surrounding structures. This examination offers a significant advance in maxillofacial lesions detection with an excellent anatomic resolution. The aim of this research was to evaluate the validity of two protocols, in axial sections, in simulated mandibular lesions. Two CT protocols were obtained in dry mandibles in which perforations were done simulating lesions. Two observers, previously calibrated, evaluated the images according to different parameters. The results indicated that the sensitivity and specificity in lesion detection were 100% for both protocols, but the detection of loci number of multilocular lesions and the location and detection of medullar invasion obtained reduced validity values, which were influenced by the acquisition protocol. We concluded that thinner axial slices and reconstructions were more effective in detecting early medullar invasion and loci number. Thicker protocols were not considered appropriate to detect multilocular lesions and early stages of medullar invasion.A tomografia Computadorizada é a técnica de escolha no exame de lesões ósseas orais e maxilo-faciais porque proporciona a visualização de tecidos duros e moles em aquisição única e sem sobreposição de estruturas adjacentes. Este exame oferece um avanço significativo na detecção de lesões maxilo-faciais, com excelente resolução anatômica. O objetivo desta pesquisa foi avaliar a validade de dois protocolos, em secções axiais, em lesões simuladas de mandíbula. Dois protocolos de TC foram obtidos em mandíbulas secas em que foram feitas perfurações, simulando lesões. Dois observadores previamente calibrados avaliaram as imagens seguindo parâmetros diversos. Como resultados pudemos observar que a sensibilidade e a especificidade foram

  9. Esclerose sistêmica progressiva: aspectos na tomografia computadorizada de alta resolução Progressive systemic sclerosis: high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Emerson L. Gasparetto

    2005-09-01

    Full Text Available OBJETIVO: Descrever os achados de tomografia computadorizada de alta resolução de pacientes com esclerose sistêmica pulmonar, independentemente dos sintomas respiratórios. MATERIAIS E MÉTODOS: Foram revisados 73 exames de tomografia computadorizada de alta resolução de 44 pacientes com diagnóstico de esclerodermia estabelecido através de critérios clínicos e laboratoriais. Os exames foram revisados por dois radiologistas, que estabeleceram os achados por consenso. RESULTADOS: Em 91,8% (n = 67 dos exames observaram-se alterações. Os principais achados foram lesões de padrão reticular (90,4%, opacidades em vidro-fosco (63%, bronquiectasias e bronquiolectasias de tração (56,2%, dilatação esofagiana (46,6%, faveolamento (28,8% e sinais de hipertensão pulmonar (15,6%. Na maioria dos casos as lesões eram bilaterais (89% e simétricas (58,5%. Quanto à localização, houve predomínio de lesões basais (91,2% e periféricas (92,2%. CONCLUSÃO: A esclerose sistêmica progressiva acarreta fibrose pulmonar na maioria dos pacientes, caracterizada principalmente por lesão reticular basal e periférica.OBJECTIVE: To describe the high-resolution computed tomography findings in the lung of patients with systemic sclerosis, independently of the respiratory symptoms. MATERIALS AND METHODS: Seventy-three high-resolution computed tomography scans of 44 patients with clinical diagnosis of systemic sclerosis were reviewed and defined by the consensus of two radiologists. RESULTS: Abnormalities were seen in 91.8% (n = 67 of the scans. The most frequent findings were reticular pattern (90.4%, ground-glass opacities (63%, traction bronchiectasis and bronchiolectasis (56.2%, esophageal dilatation (46.6%, honeycombing pattern (28.8% and signs of pulmonary hypertension (15.6%. In most cases the lesions were bilateral (89% and symmetrical (58.5%. The lesions were predominantly located in the basal (91.2% and peripheral (92.2% regions. CONCLUSION: In

  10. Nasoangiofibroma juvenil: concordância interobservadores no estadiamento por tomografia computadorizada Juvenile nasopharyngeal angiofibroma: interobserver agreement in cancer staging using computed tomography

    Directory of Open Access Journals (Sweden)

    Jefferson Luiz Gusso

    2001-08-01

    Full Text Available Com o advento da tomografia computadorizada, a avaliação dos locais de acometimento e extensão do nasoangiofibroma juvenil tornou-se mais precisa, o que facilitou o correto estadiamento pré-operatório. O objetivo deste trabalho é avaliar a concordância interobservadores, por meio da análise por tomografia computadorizada, de 15 casos de nasoangiofibroma juvenil em relação à extensão para locais relacionados com altos índices de recidivas. Todos os pacientes eram do sexo masculino, com idade média de 15,8 anos. A análise da concordância entre os observadores quanto à extensão e envolvimento da fossa infratemporal, seios esfenóide e cavernoso e fossa craniana média foi excelente, em relação à fissura orbitária superior foi boa e em relação à base do processo pterigóide e fossa craniana anterior foi ruim. Concluiu-se que a análise apresenta alta concordância entre os observadores para os locais estabelecidos, com exceção da base do processo pterigóide e da fossa craniana anterior.The advent of computed tomography permitted a much more precise evaluation of tumor localization, thus facilitating presurgical staging. The objective of this study was to evaluate the interobserver agreement on the analysis of computed tomography scans of 15 patients with juvenile nasopharyngeal angiofibroma, regarding assessment of tumor extension to sites of high recurrence rate. All patients were male and had a mean age of 15.8 years. The results of the interobserver agreement analysis regarding tumor invasion and extension to the infratemporal fossa, cavernous sinus, sphenoid sinus and medium cranial fossa were excellent. Identification of involvement of the superior orbital fissure was considered good. Interobserver agreement regarding tumor extension to the base of pterigoid process and anterior cranial fossa was considered poor. We concluded that there is a very good interobserver agreement on the evaluation of the established

  11. Description and calibration beamline SEM/Ion Chamber Current Digitizer

    International Nuclear Information System (INIS)

    Schoo, D.

    1994-05-01

    This report discusses the following on beamline SEM/ion chamber current digitizers: Module description; testing and calibration; common setup procedures; summary of fault indications and associated causes; summary of input and output connections; SEM conversion constant table; ion chamber conversion constant table; hexadecimal to decimal conversion table; and schematic diagram

  12. lsnjbhakta@gmail.com A Comparative SEM-EDS Elemental

    African Journals Online (AJOL)

    Michael Horsfall

    effect on food production in terrestrial and aquatic compartment in ... Processing and SEM-EDS analysis of mud: In the laboratory, the ... and for SEM image observation was 15 kV, applying .... by weathering in the Omi acid clay deposit, Japan.

  13. On the Nature of SEM Estimates of ARMA Parameters.

    Science.gov (United States)

    Hamaker, Ellen L.; Dolan, Conor V.; Molenaar, Peter C. M.

    2002-01-01

    Reexamined the nature of structural equation modeling (SEM) estimates of autoregressive moving average (ARMA) models, replicated the simulation experiments of P. Molenaar, and examined the behavior of the log-likelihood ratio test. Simulation studies indicate that estimates of ARMA parameters observed with SEM software are identical to those…

  14. Structural Equations and Causal Explanations: Some Challenges for Causal SEM

    Science.gov (United States)

    Markus, Keith A.

    2010-01-01

    One common application of structural equation modeling (SEM) involves expressing and empirically investigating causal explanations. Nonetheless, several aspects of causal explanation that have an impact on behavioral science methodology remain poorly understood. It remains unclear whether applications of SEM should attempt to provide complete…

  15. The influence of environment temperature on SEM image quality

    International Nuclear Information System (INIS)

    Chen, Li; Liu, Junshan

    2015-01-01

    As the structure dimension goes down to the nano-scale, it often requires a scanning electron microscope (SEM) to provide image magnification up to 100 000  ×. However, SEM images at such a high magnification usually suffer from high resolution value and low signal-to-noise ratio, which results in low quality of the SEM image. In this paper, the quality of the SEM image is improved by optimizing the environment temperature. The experimental results indicate that at 100 000  ×, the quality of the SEM image is influenced by the environment temperature, whereas at 50 000  × it is not. At 100 000  × the best SEM image quality can be achieved from the environment temperature ranging 292 from 294 K, and the SEM image quality evaluated by the double stimulus continuous quality scale method can increase from grade 1 to grade 5. It is expected that this image quality improving method can be used in routine measurements with ordinary SEMs to get high quality images by optimizing the environment temperature. (paper)

  16. Design and Use of the Simple Event Model (SEM)

    NARCIS (Netherlands)

    van Hage, W.R.; Malaisé, V.; Segers, R.H.; Hollink, L.

    2011-01-01

    Events have become central elements in the representation of data from domains such as history, cultural heritage, multimedia and geography. The Simple Event Model (SEM) is created to model events in these various domains, without making assumptions about the domain-specific vocabularies used. SEM

  17. Canticum Novum: música sem palavras e palavras sem som no pensamento de Santo Agostinho

    OpenAIRE

    Mammì, Lorenzo

    2000-01-01

    NO De Magistro, Santo Agostinho coloca a reza e o canto numa posição similar, à margem das funções imediatamente comunicativas da linguagem. A reflexão agostiniana sobre a reza se baseia nos hábitos cristãos da leitura, da oração e da meditação silenciosas. Há sobre o canto, na prática igualmente inovadora do jubilus, melodia sem palavra destinada aos momentos mais intensos e gaudiosos da liturgia. A oração silenciosa e o jubilus são temas recorrentes da literatura patrística, mas Agostinho o...

  18. Automated CD-SEM metrology for efficient TD and HVM

    Science.gov (United States)

    Starikov, Alexander; Mulapudi, Satya P.

    2008-03-01

    CD-SEM is the metrology tool of choice for patterning process development and production process control. We can make these applications more efficient by extracting more information from each CD-SEM image. This enables direct monitors of key process parameters, such as lithography dose and focus, or predicting the outcome of processing, such as etched dimensions or electrical parameters. Automating CD-SEM recipes at the early stages of process development can accelerate technology characterization, segmentation of variance and process improvements. This leverages the engineering effort, reduces development costs and helps to manage the risks inherent in new technology. Automating CD-SEM for manufacturing enables efficient operations. Novel SEM Alarm Time Indicator (SATI) makes this task manageable. SATI pulls together data mining, trend charting of the key recipe and Operations (OPS) indicators, Pareto of OPS losses and inputs for root cause analysis. This approach proved natural to our FAB personnel. After minimal initial training, we applied new methods in 65nm FLASH manufacture. This resulted in significant lasting improvements of CD-SEM recipe robustness, portability and automation, increased CD-SEM capacity and MT productivity.

  19. SEM-EBSP能知道些什么

    Institute of Scientific and Technical Information of China (English)

    张唯敏

    2003-01-01

    @@ 1 SEM-EBSP是什么 所谓SEM-EBSP是指采用在扫描电子显微镜(SEM)镜体中的反射电子菊池线衍射的结晶方位分析.被称为菊池图形的衍射图形可因结晶的稍许倾斜而大大地改变其位置,因此,通过解析菊池图形就能正确地知道结晶方位.

  20. Improvement of geometrical measurements from 3D-SEM reconstructions

    DEFF Research Database (Denmark)

    Carli, Lorenzo; De Chiffre, Leonardo; Horsewell, Andy

    2009-01-01

    The quantification of 3D geometry at the nanometric scale is a major metrological challenge. In this work geometrical measurements on cylindrical items obtained with a 3D-SEM were investigated. Two items were measured: a wire gauge having a 0.25 mm nominal diameter and a hypodermic needle having...... that the diameter estimation performed using the 3D-SEM leads to an overestimation of approx. 7% compared to the reference values obtained using a 1-D length measuring machine. Standard deviation of SEM measurements performed on the wire gauge is approx. 1.5 times lower than the one performed on the hypodermic...

  1. Improvement of CD-SEM mark position measurement accuracy

    Science.gov (United States)

    Kasa, Kentaro; Fukuhara, Kazuya

    2014-04-01

    CD-SEM is now attracting attention as a tool that can accurately measure positional error of device patterns. However, the measurement accuracy can get worse due to pattern asymmetry as in the case of image based overlay (IBO) and diffraction based overlay (DBO). For IBO and DBO, a way of correcting the inaccuracy arising from measurement patterns was suggested. For CD-SEM, although a way of correcting CD bias was proposed, it has not been argued how to correct the inaccuracy arising from pattern asymmetry using CD-SEM. In this study we will propose how to quantify and correct the measurement inaccuracy affected by pattern asymmetry.

  2. Análise computadorizada de imagens de plântulas para avaliação do vigor de sementes de milho, em comparação a testes tradicionais

    OpenAIRE

    Danielle Otte Carrara Castan

    2015-01-01

    O aprimoramento dos testes de vigor e a possibilidade da inserção de novos recursos computacionais para avaliação eficiente do potencial fisiológico de sementes tem despertado grande interesse da pesquisa e dos tecnologistas de sementes. O objetivo desta pesquisa foi avaliar o potencial fisiológico de sementes de milho utilizando sistemas de análise computadorizada de imagens de plântulas (SVIS® e Vigor-S), comparativamente a outros métodos utilizados para avaliação do vigor dessa espécie. Ut...

  3. Infrared spectra, Raman laser, XRD, DSC/TGA and SEM ...

    Indian Academy of Sciences (India)

    Administrator

    cussed and the X-ray diffraction, scanning electron microscopy (SEM) and atomic force microscope (AFM) ... acetamide as a simple organic compound at high tempera- ture has less ..... properties of selenium surface, AFM-microscopy tapping.

  4. Novel field emission SEM column with beam deceleration technology

    Energy Technology Data Exchange (ETDEWEB)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-11-15

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications.

  5. Role of scanning electron microscope )SEM) in metal failure analysis

    International Nuclear Information System (INIS)

    Shaiful Rizam Shamsudin; Hafizal Yazid; Mohd Harun; Siti Selina Abd Hamid; Nadira Kamarudin; Zaiton Selamat; Mohd Shariff Sattar; Muhamad Jalil

    2005-01-01

    Scanning electron microscope (SEM) is a scientific instrument that uses a beam of highly energetic electrons to examine the surface and phase distribution of specimens on a micro scale through the live imaging of secondary electrons (SE) and back-scattered electrons (BSE) images. One of the main activities of SEM Laboratory at MINT is for failure analysis on metal part and components. The capability of SEM is excellent for determining the root cause of metal failures such as ductility or brittleness, stress corrosion, fatigue and other types of failures. Most of our customers that request for failure analysis are from local petrochemical plants, manufacturers of automotive components, pipeline maintenance personnel and engineers who involved in the development of metal parts and component. This paper intends to discuss some of the technical concepts in failure analysis associated with SEM. (Author)

  6. Quantitative approach on SEM images of microstructure of clay soils

    Institute of Scientific and Technical Information of China (English)

    施斌; 李生林; M.Tolkachev

    1995-01-01

    The working principles of Videolab Image Processing System (VIPS), the examining methods of orientation of microstructural units of clay soils and analysing results on SEM images of some typical microstructures of clay soils using the VIPS are introduced.

  7. semPLS: Structural Equation Modeling Using Partial Least Squares

    Directory of Open Access Journals (Sweden)

    Armin Monecke

    2012-05-01

    Full Text Available Structural equation models (SEM are very popular in many disciplines. The partial least squares (PLS approach to SEM offers an alternative to covariance-based SEM, which is especially suited for situations when data is not normally distributed. PLS path modelling is referred to as soft-modeling-technique with minimum demands regarding mea- surement scales, sample sizes and residual distributions. The semPLS package provides the capability to estimate PLS path models within the R programming environment. Different setups for the estimation of factor scores can be used. Furthermore it contains modular methods for computation of bootstrap confidence intervals, model parameters and several quality indices. Various plot functions help to evaluate the model. The well known mobile phone dataset from marketing research is used to demonstrate the features of the package.

  8. Novel field emission SEM column with beam deceleration technology

    International Nuclear Information System (INIS)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-01-01

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications

  9. DETECTION OF DELAMINATION IN A COMPOSITE PLATE BY SEM

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A numerical method of integration of Green's functi ons of strip element method (SEM) is proposed. The response of ultrasonic sourc e generated by a transducer on the surface of a multi-ply composite plate conta ining a delamination is analyzed by the use of SEM. The numerical results show that the scanning features of the ultrasonic waves may be used to identify the d elamination inside the composite plate .

  10. A methodological basis for SEM autoradiography: biosynthesis and radioligand binding

    International Nuclear Information System (INIS)

    Cheng, G.; Hodges, G.M.; Trejdosiewicz, L.K.

    1985-01-01

    A method is described for scanning electron microscope (SEM) autoradiography whereby preservation of high resolution cell surface details is retained together with degelatination of the emulsion without gross loss or redistribution of silver grains. This method should provide a convenient medium-sized marker for SEM (using secondary, backscattered electron and X-ray imaging) topographic studies of biosynthesized molecules, and of cell surface receptors and antigens, using indirect or direct labelling procedures with radio-labelled ligands. (author)

  11. Avaliação do número de células caliciformes nas criptas da mucosa colônica com e sem trânsito intestinal

    Directory of Open Access Journals (Sweden)

    Rodrigo de Oliveira Mello

    Full Text Available OBJETIVO: Medir a espessura das criptas e quantificar o número de células caliciformes comparando a mucosa cólica com e sem trânsito intestinal, relacionando-as ao tempo de exclusão. MÉTODOS: Sessenta ratos Wistar, foram distribuídos em três grupos com 20 animais segundo a operação final para a retirada dos cólons, realizadas em seis, 12 ou 18 semanas. Em cada grupo, 15 animais foram submetidos à derivação do trânsito por colostomia proximal no cólon esquerdo e fístula mucosa distal e cinco apenas à laparotomia (controle. Os cólons com e sem trânsito fecal foram removidos, processados, submetidos a cortes histológicos corados pela hematoxilina-eosina. A altura das criptas colônicas e o número de células caliciformes foram mensurados por morfometria computadorizada. Foram utilizados os testes t de Student e Kruskal-Wallis para comparação e análise de variância, estabelecendo-se nível de significância de 5% (p<0,05. RESULTADOS: A altura das criptas diminui nos segmentos sem trânsito fecal (p=0,0001, reduzindo entre seis e 12 semanas de exclusão (p=0,0003, estabilizando-se após este período. O número de células caliciformes nas criptas é menor nos segmentos sem trânsito após 12 e 18 semanas (p=0,0001, porém aumenta com o decorrer do tempo de exclusão (p=0,04 CONCLUSÃO: A exclusão do trânsito intestinal diminui a espessura das criptas colônicas e o número de células caliciformes nos segmentos sem trânsito. Existe aumento do número de células caliciformes com o decorrer do tempo de exclusão.

  12. FIB-SEM cathodoluminescence tomography: practical and theoretical considerations.

    Science.gov (United States)

    De Winter, D A M; Lebbink, M N; Wiggers De Vries, D F; Post, J A; Drury, M R

    2011-09-01

    Focused ion beam-scanning electron microscope (FIB-SEM) tomography is a powerful application in obtaining three-dimensional (3D) information. The FIB creates a cross section and subsequently removes thin slices. The SEM takes images using secondary or backscattered electrons, or maps every slice using X-rays and/or electron backscatter diffraction patterns. The objective of this study is to assess the possibilities of combining FIB-SEM tomography with cathodoluminescence (CL) imaging. The intensity of CL emission is related to variations in defect or impurity concentrations. A potential problem with FIB-SEM CL tomography is that ion milling may change the defect state of the material and the CL emission. In addition the conventional tilted sample geometry used in FIB-SEM tomography is not compatible with conventional CL detectors. Here we examine the influence of the FIB on CL emission in natural diamond and the feasibility of FIB-SEM CL tomography. A systematic investigation establishes that the ion beam influences CL emission of diamond, with a dependency on both the ion beam and electron beam acceleration voltage. CL emission in natural diamond is enhanced particularly at low ion beam and electron beam voltages. This enhancement of the CL emission can be partly explained by an increase in surface defects induced by ion milling. CL emission enhancement could be used to improve the CL image quality. To conduct FIB-SEM CL tomography, a recently developed novel specimen geometry is adopted to enable sequential ion milling and CL imaging on an untilted sample. We show that CL imaging can be manually combined with FIB-SEM tomography with a modified protocol for 3D microstructure reconstruction. In principle, automated FIB-SEM CL tomography should be feasible, provided that dedicated CL detectors are developed that allow subsequent milling and CL imaging without manual intervention, as the current CL detector needs to be manually retracted before a slice can be milled

  13. Computerized electrocardiography in American pit bull terrier dogsEletrocardiografia computadorizada em cães da raça American pit bull terrier

    Directory of Open Access Journals (Sweden)

    Mauro José Lahm Cardoso

    2013-10-01

    Full Text Available Electrocardiography (ECG is an essential examination for evaluation of patient with heart disease is great importance the diagnosis of arrhythmias. The examination can determine source f rhythm and frequency depolarization heart, providing information in clinical status myocardium, since deflections P-QRS-T tracing can be altered by disease or physiological factor. With advancement of computer technology, computerized electrocardiography has been used in human medicine as auxiliary diagnostic method and currently is being increasingly used in veterinary medicine. The objectives this study were to study e computerized electrocardiographic parameters in dogs breed American Pit Bull Terrier, comparing them with patterns species. In present study, we evaluated electrocardiographic examinations 42 dogs the breed American Pit Bull clinically healthy, 22 males and 20 females, aged between 1 and 6 years. Sinus rhythm was observed in 57% of dogs showed sinus rhythm and only 26% were wandering pacemaker. The electrocardiographic values obtained from these dogs computerized ECG were within the normal range of species, except the duration of the P wave which had longer than 0.04 seconds in 24% of dogs. We conclude that the dogs of the breed American Pit Bull Terrier have the same electrocardiographic values obtained in other breeds by the computerized method, except for the increase in P-wave duration. A eletrocardiografia (ECG é um exame essencial para avaliação do paciente com doença cardíaca, sendo de grande importância para o diagnóstico das arritmias. O exame pode determinar a origem do ritmo e a freqüência de despolarização do coração, fornecendo informações do estado clínico do miocárdio, uma vez que as deflexões P-QRS-T do traçado podem ser alteradas por uma enfermidade ou fator fisiológico. Com o avanço da informática, a eletrocardiografia computadorizada tem sido utilizada na medicina humana e veterinária como método de

  14. Aspectos da tomografia computadorizada no linfoma em pacientes abaixo de 20 anos de idade Computed tomography findings in patients less than 20 years old with lymphoma

    Directory of Open Access Journals (Sweden)

    Adriana Moreira Viana Borba

    2007-04-01

    Full Text Available OBJETIVO: Descrever os achados gerais do linfoma em pacientes abaixo de 20 anos de idade e por subtipo histológico. MATERIAIS E MÉTODOS: Estudo retrospectivo do arquivo digital de tomografia computadorizada do Centro de Controle do Câncer do Hospital Universitário Pedro Ernesto da Universidade do Estado do Rio de Janeiro, no período de março de 2003 a julho de 2005. Dos 22 casos - 16 do sexo masculino e 6 do sexo feminino, com média de idade de 11,5 anos -, 12 eram do subtipo Hodgkin e 10 eram não-Hodgkin. RESULTADOS: Dos achados gerais, verificamos as linfonodomegalias mediastinais como o mais freqüente (59%, com predomínio no grupo Hodgkin (75%, seguido por hepatoesplenomegalia (50% e linfonodomegalias cervicais e retroperitoneais (27,3%. No subtipo Hodgkin houve predomínio do acometimento linfonodal, em sucessivas cadeias, seguido pela hepatoesplenomegalia (50%. Verificamos um caso de massa tonsilar unilateral, opacidade pulmonar em "vidro-fosco" e nódulos renais. No subtipo não-Hodgkin houve predomínio extranodal caracterizado por hepatoesplenomegalia (50%, espessamento de alça intestinal (40%, derrame pleural (30%, nódulo pulmonar (20%, ascite (10%, derrame pericárdico (10% e lesões ósseas mistas (10%. CONCLUSÃO: A tomografia computadorizada é de grande valia no diagnóstico, estadiamento e seguimento do linfoma, com achados de alerta como massa linfonodal, notadamente mediastinal, hepatoesplenomegalia, massa unilateral na tonsila e espessamento parietal de alça intestinal.OBJECTIVE: To describe the general findings of lymphoma and their histological patterns in patients less than 20 years old. MATERIALS AND METHODS: Twenty-two cases (16 male and 6 female, mean age 11.5 years from the digital archive of computed tomography at the Cancer Control Center of "Hospital Universitário Pedro Ernesto - Universidade do Estado do Rio de Janeiro", Rio de Janeiro, RJ, Brazil, were retrospectively analyzed in the period between

  15. Análise Computadorizada da Cardiotocografia Anteparto em Gestações de Alto Risco Computerized Antepartum Cardiotocography Analysis in High Risk Pregnancies

    Directory of Open Access Journals (Sweden)

    Roseli Mieko Yamamoto Nomura

    2002-01-01

    Full Text Available Objetivos: analisar a freqüência dos resultados das cardiotocografias computadorizadas realizadas em gestantes de alto risco e relacionar o critério proposto pelo sistema com os resultados perinatais. Métodos: estudamos prospectivamente 233 gestantes de alto risco que realizaram 485 cardiotocografias computadorizadas. Foram excluídos casos de anomalias fetais e os exames com perda de sinal superior a 20% (proporção de episódios de 3,75 milissegundos do traçado onde não se constata intervalo de pulso por perda de captação dos sinais de batimentos cardíacos fetais. Para estudo da associação da cardiotocografia com os resultados perinatais, analisou-se o último exame realizado na semana anterior ao parto (71 casos, excluindo-se casos com diagnóstico de diástole zero ou reversa na dopplervelocimetria das artérias umbilicais. Resultados: após a exclusão de 33 exames com perda de sinal superior a 20%, constatou-se que 404 cardiotocografias foram caracterizadas como normais (83,3%. Quanto à duração do exame, em 62,1% foi de até 20 minutos e em 79,0% de até 30 minutos. A análise das correlações com os resultados perinatais demonstrou associação significativa (pPurpose: to study computerized cardiotocography performed in high-risk pregnancies, analyze the results, and correlate the criteria to perinatal results. Patients and Methods: two hundred and thirty-three high-risk pregnancies were studied prospectively, performing a total of 485 computerized cardiotocographies. The exclusion criteria included fetal anomalies and signal loss over 20% (proportion of 3.75-millisecond periods in which there were no valid pulse intervals. The perinatal results of 71 pregnancies were correlated to the last cardiotocography, performed at least seven days before birth, excluding patients with absent or reversed end diastolic velocities in the umbilical arteries. Results: thirty-three examinations with signal loss over 20% were excluded. The

  16. Sparsity-Based Super Resolution for SEM Images.

    Science.gov (United States)

    Tsiper, Shahar; Dicker, Or; Kaizerman, Idan; Zohar, Zeev; Segev, Mordechai; Eldar, Yonina C

    2017-09-13

    The scanning electron microscope (SEM) is an electron microscope that produces an image of a sample by scanning it with a focused beam of electrons. The electrons interact with the atoms in the sample, which emit secondary electrons that contain information about the surface topography and composition. The sample is scanned by the electron beam point by point, until an image of the surface is formed. Since its invention in 1942, the capabilities of SEMs have become paramount in the discovery and understanding of the nanometer world, and today it is extensively used for both research and in industry. In principle, SEMs can achieve resolution better than one nanometer. However, for many applications, working at subnanometer resolution implies an exceedingly large number of scanning points. For exactly this reason, the SEM diagnostics of microelectronic chips is performed either at high resolution (HR) over a small area or at low resolution (LR) while capturing a larger portion of the chip. Here, we employ sparse coding and dictionary learning to algorithmically enhance low-resolution SEM images of microelectronic chips-up to the level of the HR images acquired by slow SEM scans, while considerably reducing the noise. Our methodology consists of two steps: an offline stage of learning a joint dictionary from a sequence of LR and HR images of the same region in the chip, followed by a fast-online super-resolution step where the resolution of a new LR image is enhanced. We provide several examples with typical chips used in the microelectronics industry, as well as a statistical study on arbitrary images with characteristic structural features. Conceptually, our method works well when the images have similar characteristics, as microelectronics chips do. This work demonstrates that employing sparsity concepts can greatly improve the performance of SEM, thereby considerably increasing the scanning throughput without compromising on analysis quality and resolution.

  17. Trauma dos ossos temporais e suas complicações: aspectos na tomografia computadorizada Temporal bone trauma and complications: computed tomography findings

    Directory of Open Access Journals (Sweden)

    Ana Maria Doffémond Costa

    2013-04-01

    Full Text Available A maioria das fraturas dos ossos temporais resulta de traumas cranianos bruscos, de alta energia, estando muitas vezes relacionadas a outras fraturas cranianas ou a politraumatismo. As fraturas e os deslocamentos da cadeia ossicular, na orelha média, representam umas das principais complicações das injúrias nos ossos temporais e, por isso, serão abordadas de maneira mais profunda neste artigo. Os outros tipos de injúrias englobam as fraturas labirínticas, fístula dural, paralisia facial e extensão da linha de fratura ao canal carotídeo. A tomografia computadorizada tem papel fundamental na avaliação inicial dos pacientes politraumatizados, pois é capaz de identificar injúrias em importantes estruturas que podem causar graves complicações, como perda auditiva de condução ou neurossensorial, tonturas e disfunções do equilíbrio, fístulas perilinfáticas, paralisia do nervo facial, lesões vasculares, entre outras.Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others.

  18. Características da demanda por tomografia computadorizada crânio-encefálica motivos e custos dos exames

    Directory of Open Access Journals (Sweden)

    Ana Tereza Ramos de Oliveira

    1992-03-01

    Full Text Available Foram levantadas as 2860 tomografias computadorizadas crânio-encefálicas (TCCE feitas em um dos três serviços da cidade do Salvador, Brasil, sendo: caracterizados o perfil do usuário e a procedência da demanda; analisados os motivos dos exames e os custos com TCCE normais e anormais. Foram constatadas frequências altas de exames normais: (a para o sexo feminino (66,0% e até os 54 anos (73,0%, neste sexo (variação de exames normais entre 65 e 80%; (b para o sexo masculino nos grupos <15, 25-34 e 35-44 anos (64,7%; (c para solicitações efetuadas pelos convênios (65,3%; (d pelos seguintes motivos, para homens e mulheres respectivamente: cefaléias (81,3 e 87,5%; desmaios/tonturas (79,3 e 78,6%; convulsões (67,3 e 70%; retardo do desenvolvimento psicomotor (72,0 e 67,7%; «distúrbios endócrinos» (75,0% em cada sexo. Proporções altas de exames anormais foram observadas pelos seguintes motivos e para homens e mulheres, respectivamente: síndrome demencial (91,7 e 83,3%; acidentes vasculares encefálicos (85,1 e 73,7%; doenças infecciosas (76,5 e 78,6%; suspeitas de tumor (65,8 e 55,4%; e traumatismo crâ-nioencefálico, 63,6% no sexo masculino. No total, os custos com as TCC normais corresponderam a US$ 565,255 e com as anormais, US$ 381,247; para os convênios, os custos com TCC normais foram 2,2 vezes superiores ao INAMPS e 2,8 vezes superiores àqueles da medicina privada.

  19. Colonografia por tomografia computadorizada na visão do médico encaminhador: qual o seu valor segundo a visão de especialistas?

    Directory of Open Access Journals (Sweden)

    Marcelo Longo Kierszenbaum

    2014-06-01

    Full Text Available Objetivo: Mapear a visão dos cirurgiões sobre o papel da colonografia por tomografia computadorizada (CTC. Materiais e Métodos: Envio de questionário eletrônico aos membros do Colégio Brasileiro de Cirurgiões. O questionário constou de 16 questões de múltipla escolha que abordaram dados demográficos e conhecimentos gerais sobre a CTC. Resultados: Foram obtidas 144 respostas; 90,3% dos especialistas eram homens, 60% com menos de 30 anos de formado, 77,1% eram gastrocirurgiões, 22,9% eram cirurgiões gerais, 53,5% encontravam-se na vida acadêmica e 59,7% exerciam sua atividade profissional em cidades com mais de 500.000 habitantes. Em relação ao conhecimento da CTC, 84,7% conheciam o método, 70,8% sabiam como é realizado, 56,9% relataram conhecer o preparo intestinal utilizado, 31,3% utilizavam o método e 53,5% conheciam algum serviço de CTC na cidade em que atuam. Cerca de metade dos profissionais não conhecia a precisa indicação do método. Profissionais que atuam em cidades com mais de 500.000 habitantes conhecem e utilizam mais o método (p < 0,005. Houve uma tendência de os profissionais com carreira acadêmica utilizarem mais o método. Conclusão: A CTC, embora ainda pouco utilizada em nosso meio, é bastante conhecida, principalmente em grandes centros urbanos e no ambiente acadêmico.

  20. An electron moiré method for a common SEM

    Institute of Scientific and Technical Information of China (English)

    Y.M.Xing; S.Kishimoto; Y.R.Zhao

    2006-01-01

    In the electron moiré method,a high-frequency grating is used to measure microscopic deformation,which promises significant potential applications for the method in the microscopic analysis of materials.However,a special beam scanning control device is required to produce a grating and generate a moiré fringe pattern for the scanning electron microscope (SEM).Because only a few SEMs used in the material science studies are equipped with this device,the use of the electron moiré method is limited.In this study,an electron moiré method for a common SEM without the beam control device is presented.A grating based on a multi-scanning concept is fabricated in any observing mode.A real-time moiré pattern can also be generated in the SEM or an optical filtering system.Without the beam control device being a prerequisite,the electron moiré method can be more widely used.The experimental results from three different types of SEMS show that high quality gratings with uniform lines and less pitch error can be fabricated by this method,and moiré patterns can also be correctly generated.

  1. SEM facility for examination of reactive and radioactive materials

    International Nuclear Information System (INIS)

    Downs, G.L.; Tucker, P.A.

    1977-01-01

    A scanning electron microscope (SEM) facility for the examination of tritium-containing materials is operational at Mound Laboratory. The SEM is installed with the sample chamber incorporated as an integral part of an inert gas glovebox facility to enable easy handling of radioactive and pyrophoric materials. A standard SEM (ETEC Model B-1) was modified to meet dimensional, operational, and safety-related requirements. a glovebox was designed and fabricated which permitted access with the gloves to all parts of the SEM sample chamber to facilitate director and accessory replacement and repairs. A separate console combining the electron optical column and specimen chamber was interfaced to the glovebox by a custom-made, neoprene bellows so that the vibrations normally associated with the blowers and pumps were damped. Photomicrographs of tritiated pyrophoric materials show the usefulness of this facility. Some of the difficulties involved in the investigation of these materials are also discussed. The SEM is also equipped with an energy dispersive x-ray detector (ORTEC) and a Secondary Ion Mass Spectrometer (3M) attachments. This latter attachment allows analysis of secondary ions with masses ranging from 1-300 amu. (Auth.)

  2. Recent advances in 3D SEM surface reconstruction.

    Science.gov (United States)

    Tafti, Ahmad P; Kirkpatrick, Andrew B; Alavi, Zahrasadat; Owen, Heather A; Yu, Zeyun

    2015-11-01

    The scanning electron microscope (SEM), as one of the most commonly used instruments in biology and material sciences, employs electrons instead of light to determine the surface properties of specimens. However, the SEM micrographs still remain 2D images. To effectively measure and visualize the surface attributes, we need to restore the 3D shape model from the SEM images. 3D surface reconstruction is a longstanding topic in microscopy vision as it offers quantitative and visual information for a variety of applications consisting medicine, pharmacology, chemistry, and mechanics. In this paper, we attempt to explain the expanding body of the work in this area, including a discussion of recent techniques and algorithms. With the present work, we also enhance the reliability, accuracy, and speed of 3D SEM surface reconstruction by designing and developing an optimized multi-view framework. We then consider several real-world experiments as well as synthetic data to examine the qualitative and quantitative attributes of our proposed framework. Furthermore, we present a taxonomy of 3D SEM surface reconstruction approaches and address several challenging issues as part of our future work. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A methodology for extending domain coverage in SemRep.

    Science.gov (United States)

    Rosemblat, Graciela; Shin, Dongwook; Kilicoglu, Halil; Sneiderman, Charles; Rindflesch, Thomas C

    2013-12-01

    We describe a domain-independent methodology to extend SemRep coverage beyond the biomedical domain. SemRep, a natural language processing application originally designed for biomedical texts, uses the knowledge sources provided by the Unified Medical Language System (UMLS©). Ontological and terminological extensions to the system are needed in order to support other areas of knowledge. We extended SemRep's application by developing a semantic representation of a previously unsupported domain. This was achieved by adapting well-known ontology engineering phases and integrating them with the UMLS knowledge sources on which SemRep crucially depends. While the process to extend SemRep coverage has been successfully applied in earlier projects, this paper presents in detail the step-wise approach we followed and the mechanisms implemented. A case study in the field of medical informatics illustrates how the ontology engineering phases have been adapted for optimal integration with the UMLS. We provide qualitative and quantitative results, which indicate the validity and usefulness of our methodology. Published by Elsevier Inc.

  4. SemGroup acquisition of central Alberta midstream : case study

    International Nuclear Information System (INIS)

    Purcell, T.

    2005-01-01

    A case study of SemGroup's acquisition of Central Alberta Midstream was presented. SemCAMS specializes in providing more efficient supply, storage, and distribution assets and services. Seminole Canada Gas is a leading independent natural gas marketing and energy asset management company that currently markets 369 MMbtu per day. The company purchases natural gas in western Canada for fee-based marketing services while also managing firm transportation contracts and providing gas storage for third party customers. SemCAMS owns the largest sour gas processor in Alberta as well as 3 sour gas processing plants, 600 miles of gathering pipeline, and a sweet gas processing plant. the company is also planning increased drilling and production activities and is now pursuing aggressive land acquisition policies. Over 25,000 square miles of land have been acquired. It was concluded that midstream companies should be customer-focused, provide reliability and guarantees, infrastructure investment and optimization. tabs., figs

  5. Critical factors in SEM 3D stereo microscopy

    DEFF Research Database (Denmark)

    Marinello, F.; Bariano, P.; Savio, E.

    2008-01-01

    This work addresses dimensional measurements performed with the scanning electron microscope (SEM) using 3D reconstruction of surface topography through stereo-photogrammetry. The paper presents both theoretical and experimental investigations, on the effects of instrumental variables and measure......This work addresses dimensional measurements performed with the scanning electron microscope (SEM) using 3D reconstruction of surface topography through stereo-photogrammetry. The paper presents both theoretical and experimental investigations, on the effects of instrumental variables...... factors are recognized: the first one is related to the measurement operation and the instrument set-up; the second concerns the quality of scanned images and represents the major criticality in the application of SEMs for 3D characterizations....

  6. Annual International DIC Society Conference and SEM Fall Conference

    CERN Document Server

    Reu, Phillip

    2017-01-01

    This collection represents a single volume of technical papers presented at the Annual International DIC Society Conference and SEM Fall Conference organized by the Society for Experimental Mechanics and Sandia National Laboratories and held in Philadelphia, PA, November 7-10, 2016. The volume presents early findings from experimental, standards development and various other investigations concerning digital image correlation - an important area within Experimental Mechanics. The area of Digital Image Correlation has been an integral track within the SEM Annual Conference spearheaded by Professor Michael Sutton from the University of South Carolina. In 2016, the SEM and Sandia joined their collaborative strengths to launch a standing fall meeting focusing specifically on developments in the area of Digital Image Correlation. The contributed papers within this volume span numerous technical aspects of DIC including standards development for the industry. .

  7. SemVisM: semantic visualizer for medical image

    Science.gov (United States)

    Landaeta, Luis; La Cruz, Alexandra; Baranya, Alexander; Vidal, María.-Esther

    2015-01-01

    SemVisM is a toolbox that combines medical informatics and computer graphics tools for reducing the semantic gap between low-level features and high-level semantic concepts/terms in the images. This paper presents a novel strategy for visualizing medical data annotated semantically, combining rendering techniques, and segmentation algorithms. SemVisM comprises two main components: i) AMORE (A Modest vOlume REgister) to handle input data (RAW, DAT or DICOM) and to initially annotate the images using terms defined on medical ontologies (e.g., MesH, FMA or RadLex), and ii) VOLPROB (VOlume PRObability Builder) for generating the annotated volumetric data containing the classified voxels that belong to a particular tissue. SemVisM is built on top of the semantic visualizer ANISE.1

  8. SEM based overlay measurement between resist and buried patterns

    Science.gov (United States)

    Inoue, Osamu; Okagawa, Yutaka; Hasumi, Kazuhisa; Shao, Chuanyu; Leray, Philippe; Lorusso, Gian; Baudemprez, Bart

    2016-03-01

    With the continuous shrink in pattern size and increased density, overlay control has become one of the most critical issues in semiconductor manufacturing. Recently, SEM based overlay of AEI (After Etch Inspection) wafer has been used for reference and optimization of optical overlay (both Image Based Overlay (IBO) and Diffraction Based Overlay (DBO)). Overlay measurement at AEI stage contributes monitor and forecast the yield after formation by etch and calibrate optical measurement tools. however those overlay value seems difficult directly for feedback to a scanner. Therefore, there is a clear need to have SEM based overlay measurements of ADI (After Develop Inspection) wafers in order to serve as reference for optical overlay and make necessary corrections before wafers go to etch. Furthermore, to make the corrections as accurate as possible, actual device like feature dimensions need to be measured post ADI. This device size measurement is very unique feature of CDSEM , which can be measured with smaller area. This is currently possible only with the CD-SEM. This device size measurement is very unique feature of CD-SEM , which can be measured with smaller area. In this study, we assess SEM based overlay measurement of ADI and AEI wafer by using a sample from an N10 process flow. First, we demonstrate SEM based overlay performance at AEI by using dual damascene process for Via 0 (V0) and metal 1 (M1) layer. We also discuss the overlay measurements between litho-etch-litho stages of a triple patterned M1 layer and double pattern V0. Second, to illustrate the complexities in image acquisition and measurement we will measure overlay between M1B resist and buried M1A-Hard mask trench. Finally, we will show how high accelerating voltage can detect buried pattern information by BSE (Back Scattering Electron). In this paper we discuss the merits of this method versus standard optical metrology based corrections.

  9. Protons, ions, electrons and the future of the SEM

    International Nuclear Information System (INIS)

    Joy, D C

    2010-01-01

    The Scanning Electron Microscope (SEM) is the most widely used high performance microscope in all fields of science but it is now reaching the theoretical limits of its performance. While advances in sources, optics, and detectors, can result in some improvement in performance the ultimate resolution is limited by fundamental physical constraints. One potential alternative is a scanning microscope utilizing light ions such as H+ and He+ . Such an instrument shares all of the benefits of the conventional SEM but is free from the constraints encountered when using electrons and could significantly extend the scope and success of scanning microscopy.

  10. What Determines Lean Manufacturing Implementation? A CB-SEM Model

    Directory of Open Access Journals (Sweden)

    Tan Ching Ng

    2018-02-01

    Full Text Available This research aims to ascertain the determinants of effective Lean Manufacturing (LM. In this research, Covariance-based Structural Equation Modeling (CB-SEM analysis will be used in order to analyze the determinants. Through CB-SEM analysis, the significant key determinants can be determined and the direct relationships among determinants can be analyzed. Thus, the findings of this research can act as guidelines for achievement of LM effectiveness, not only providing necessary steps for successful implementation of lean, but also helping lean companies to achieve higher level of lean cost and time savings.

  11. A Data-Driven Approach to SEM Development at a Two-Year College

    Science.gov (United States)

    Pirius, Landon K.

    2014-01-01

    This article explores implementation of strategic enrollment management (SEM) at a two-year college and why SEM is critical to the long-term viability of an institution. This article also outlines the five initial steps needed to implement SEM, including identifying SEM leadership, building a SEM committee, developing a common understanding of…

  12. Cuticle scale measurement of animal fibers by SEM and AFM

    CSIR Research Space (South Africa)

    Notayi, M

    2013-12-01

    Full Text Available -1 51st Microscopy Society of Southern Africa (MSSA) Conference, Farm Inn, Pretoria, 3-6 December 2013 Cuticle scale measurement of animal fibers by SEM and AFM Notayi M, Engelbrechts JAA, Lee ME, Goosen WE, Hunter L and Botha AF Abstract...

  13. Estudo comparativo entre histerectomia abdominal e vaginal sem prolapso uterino

    OpenAIRE

    Lisboa, Vânio Cardoso

    2002-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Ciências Médicas. Objetivo: Comparar a histerectomia abdominal e vaginal sem prolapso uterino.

  14. SEM based CARMA time series modeling for arbitrary N

    NARCIS (Netherlands)

    Oud, J.H.L.; Völkle, M.C.; Driver, C.C.

    2018-01-01

    This article explains in detail the state space specification and estimation of first and higher-order autoregressive moving-average models in continuous time (CARMA) in an extended structural equation modeling (SEM) context for N = 1 as well as N > 1. To illustrate the approach, simulations will be

  15. DSS1/Sem1, a multifunctional and intrinsically disordered protein

    DEFF Research Database (Denmark)

    Kragelund, Birthe Brandt; Schenstrøm, Signe Marie; Rebula, Caio A.

    2016-01-01

    DSS1/Sem1 is a versatile intrinsically disordered protein. Besides being a bona fide subunit of the 26S proteasome, DSS1 associates with other protein complexes, including BRCA2-RPA, involved in homologous recombination; the Csn12-Thp3 complex, involved in RNA splicing; the integrator, involved...

  16. The principle of electron microscopy; SEM and TEM

    International Nuclear Information System (INIS)

    Fauzi, S.H.

    1992-01-01

    The article reviews the principle of electron microscopy which is used in scanning electron microscope (SEM) and transmission electron microscope (TEM). These instruments are important for the examination and analysis of the microstructural properties of solid objects. Relevance physical concept lies behind the devices are given. The main components of each device are also discussed

  17. Continuous time modeling of panel data by means of SEM

    NARCIS (Netherlands)

    Oud, J.H.L.; Delsing, M.J.M.H.; Montfort, C.A.G.M.; Oud, J.H.L.; Satorra, A.

    2010-01-01

    After a brief history of continuous time modeling and its implementation in panel analysis by means of structural equation modeling (SEM), the problems of discrete time modeling are discussed in detail. This is done by means of the popular cross-lagged panel design. Next, the exact discrete model

  18. Processing a Biological Tissue from Cryo-SEM to Replica

    Czech Academy of Sciences Publication Activity Database

    Vaškovicová, Naděžda; Hrubanová, Kamila; Krzyžánek, Vladislav

    2016-01-01

    Roč. 22, S3 (2016), s. 236-237 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : Cryo-SEM * ACE600 Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.891, year: 2016

  19. A combined optical, SEM and STM study of growth spirals

    Indian Academy of Sciences (India)

    Some novel results of a combined sequential study of growth spirals on the basal surface of the richly polytypic CdI2 crystals by optical microscopy, scanning electron microscopy (SEM) and scanning tunneling microscopy (STM) are presented and discussed. In confirmation of the known structural data, the STM pictures ...

  20. SEM Analysis of Surface Impact on Biofilm Antibiotic Treatment.

    Science.gov (United States)

    Gomes, Luciana Calheiros; Mergulhão, Filipe José

    2017-01-01

    The aim of this work was to use scanning electron microscopy (SEM) to investigate the effect of ampicillin treatment on Escherichia coli biofilms formed on two surface materials with different properties, silicone (SIL) and glass (GLA). Epifluorescence microscopy (EM) was initially used to assess biofilm formation and killing efficiency on both surfaces. This technique showed that higher bacterial colonization was obtained in the hydrophobic SIL than in the hydrophilic GLA. It has also shown that higher biofilm inactivation was attained for GLA after the antibiotic treatment (7-log reduction versus 1-log reduction for SIL). Due to its high resolution and magnification, SEM enabled a more detailed analysis of the antibiotic effect on biofilm cells, complementing the killing efficiency information obtained by EM. SEM micrographs revealed that ampicillin-treated cells have an elongated form when compared to untreated cells. Additionally, it has shown that different materials induced different levels of elongation on cells exposed to antibiotic. Biofilms formed on GLA showed a 37% higher elongation than those formed on SIL. Importantly, cell elongation was related to viability since ampicillin had a higher bactericidal effect on GLA-formed biofilms. These findings raise the possibility of using SEM for understanding the efficacy of antimicrobial treatments by observation of biofilm morphology.

  1. SEM Investigation of Superheater Deposits from Biomass-Fired Boilers

    DEFF Research Database (Denmark)

    Jensen, Peter Arendt; Frandsen, Flemming; Hansen, Jørn

    2004-01-01

    , mature superheater deposit samples were extracted from two straw-fired boilers, Masnedø and Ensted, with fuel inputs of 33 MWth and 100 MWth, respectively. SEM (scanning electron microscopy) images and EDX (energy dispersive X-ray) analyses were performed on the deposit samples. Different strategies...

  2. Correlative SEM SERS for quantitative analysis of dimer nanoparticles.

    Science.gov (United States)

    Timmermans, F J; Lenferink, A T M; van Wolferen, H A G M; Otto, C

    2016-11-14

    A Raman microscope integrated with a scanning electron microscope was used to investigate plasmonic structures by correlative SEM-SERS analysis. The integrated Raman-SEM microscope combines high-resolution electron microscopy information with SERS signal enhancement from selected nanostructures with adsorbed Raman reporter molecules. Correlative analysis is performed for dimers of two gold nanospheres. Dimers were selected on the basis of SEM images from multi aggregate samples. The effect of the orientation of the dimer with respect to the polarization state of the laser light and the effect of the particle gap size on the Raman signal intensity is observed. Additionally, calculations are performed to simulate the electric near field enhancement. These simulations are based on the morphologies observed by electron microscopy. In this way the experiments are compared with the enhancement factor calculated with near field simulations and are subsequently used to quantify the SERS enhancement factor. Large differences between experimentally observed and calculated enhancement factors are regularly detected, a phenomenon caused by nanoscale differences between the real and 'simplified' simulated structures. Quantitative SERS experiments reveal the structure induced enhancement factor, ranging from ∼200 to ∼20 000, averaged over the full nanostructure surface. The results demonstrate correlative Raman-SEM microscopy for the quantitative analysis of plasmonic particles and structures, thus enabling a new analytical method in the field of SERS and plasmonics.

  3. Revolving SEM images visualising 3D taxonomic characters

    DEFF Research Database (Denmark)

    Akkari, Nesrine; Cheung, David Koon-Bong; Enghoff, Henrik

    2013-01-01

    images taken consecutively while rotating the SEM stage 360°, which allows the structure in question to be seen from all angles of view in one plane. Seven new species of the genus Ommatoiulus collected in Tunisia are described: O. chambiensis, O. crassinigripes, O. kefi, O. khroumiriensis, O. xerophilus...

  4. Carcinoma espinocelular do conduto auditivo externo: estudo por tomografia computadorizada de seis casos Squamous cell carcinoma of the external auditory canal: computed tomography findings in six cases

    Directory of Open Access Journals (Sweden)

    Fábio Mota Gonzalez

    2005-06-01

    Full Text Available OBJETIVO: Analisar a importância da avaliação tomográfica da extensão profunda dos carcinomas espinocelulares do conduto auditivo externo. MATERIAIS E MÉTODOS: Foram realizados exames tomográficos com cortes axiais e coronais com janelas para partes moles e óssea em seis pacientes com carcinoma espinocelular do conduto auditivo externo, com idade variando entre 55 e 71 anos, internados no Hospital Heliópolis, no período entre maio de 1995 e dezembro de 2003. RESULTADOS: Dos seis pacientes, todos apresentavam aumento de partes moles no conduto auditivo externo, cinco (83,3% tinham erosão óssea e invasão da orelha média, quatro (66,7% possuíam comprometimento da mastóide e da glândula parótida, três (50% apresentavam invasão da articulação temporomandibular, dois (33,3% tinham invasão da fossa média, do canal carotídeo e linfonodomegalia júgulo-carotídea alta ipisilateral. CONCLUSÃO: A avaliação da extensão tumoral profunda fornecida pela tomografia computadorizada é importante no estadiamento clínico, possibilitando um planejamento terapêutico mais eficaz.OBJECTIVE: To evaluate the role of computed tomography in the assessment of deep extension of squamous cell carcinoma of the external auditory canal. MATERIALS AND METHODS: In the period between May 1995 and December 2003 six patients with squamous cell carcinoma of the external auditory canal were submitted to computed tomography scan at "Hospital Heliópolis", São Paulo, SP, Brazil, including axial and coronal slices with soft tissue and bone algorithms. RESULTS: Thickening of the soft tissue of the external auditory canal was seen in all patients, bone erosion and invasion of the middle ear in five (83.3%, invasion of the mastoid and parotid gland in four (66.7%, invasion of the temporomandibular joint in three (50%, and invasion of the middle cranial fossa, carotid canal and cervical lymph node enlargement in two (33.3% patients. CONCLUSION: Assessment of

  5. Mediastinoscopia contra tomografía axial computadorizada en la estadificación del carcinoma pulmonar de células no pequeñas

    Directory of Open Access Journals (Sweden)

    Edelberto Fuentes Valdés

    2002-08-01

    Full Text Available La mediastinoscopia constituye un medio diagnóstico útil en la estadificación del cáncer del pulmón, y es también utilizada para este fin la tomografía axial computadorizada (TAC, por lo que fue el propósito de este trabajo realizar un estudio que permitiera conocer la eficacia diagnóstica de ambas y compararlas entre sí. Se estudiaron 51 pacientes con diagnóstico de cáncer de pulmón de células no pequeñas. A todos se les realizó TAC y mediastinoscopia, como parte del estudio preoperatorio. La eficacia diagnóstica se determinó analizando la sensibilidad, la especificidad y los valores predictivos positivo y negativo de ambas técnicas. Para la mediastinoscopia la sensibilidad fue de 68,4 %, la especificidad y el valor predictivo positivo dieron valores de 100 % y el valor predictivo negativo de 84,6 %, con una certeza diagnóstica de 88,5 %. Los resultados para la TAC mostraron valores significativamente inferiores para los mismos parámetros: sensibilidad y valor predictivo positivo de 27,7 % y especificidad y valor predictivo negativo de 60,6 %, con una certeza diagnóstica de 49,0 %. En conclusión la mediastinoscopia resultó superior a la TAC en la detección de la enfermedad metastásica mediastinal cuando estuvo presente, lo que expresa su sensibilidad, además de que es capaz de predecir con mayor exactitud cuando el enfermo en realidad no tiene la toma linfática mediastinalAs mediastinoscopy is a useful diagnostic tool in lung cancer staging and computed axial tomography (CAT is also used to this end, a study was conducted to know the diagnostic efficiency of both and to compare them. 51 patients with diagnosis of non-small cell lung cancer were studied. All of them underwent CAT and mediastinoscopy as part of the preoperative study. The diagnostic efficiency was determined by analyzing sensitivity and specificity and the positive and negative predictive values of both techniques. In the mediastinoscopy, sensitivity

  6. Edema pulmonar hidrostático: aspectos na tomografia computadorizada de alta resolução Hydrostatic pulmonary edema: high-resolution computed tomography aspects

    Directory of Open Access Journals (Sweden)

    Cláudia Maria Cunha Ribeiro

    2006-12-01

    Full Text Available OBJETIVO: A proposta deste estudo foi caracterizar por meio de tomografia computadorizada de alta resolução do tórax as principais alterações pulmonares do edema pulmonar hidrostático. MÉTODOS: Foram analisadas, retrospectivamente, as tomografias de quinze pacientes com quadro clínico de edema pulmonar hidrostático, divididos em cinco principais grupos etiológicos: insuficiência cardíaca congestiva, valvulopatia mitral aguda, infarto agudo do miocárdio, miocardite e mediastinite fibrosante, tendo sido sete pacientes classificados no primeiro grupo e dois em cada um dos demais. RESULTADOS: Os principais achados do edema hidrostático foram opacidades em vidro fosco (100%, espessamento dos septos interlobulares (100%, derrame pleural (87% e espessamento do interstício peribroncovascular (80%. Outros achados menos comuns foram aumento do calibre dos vasos, consolidações e nódulos do espaço aéreo. CONCLUSÃO: O padrão predominante encontrado nos pacientes estudados foi o de opacidades em vidro fosco associadas a espessamento dos septos interlobulares (padrão de pavimentação em mosaico, com derrame pleural bilateral, predominante à direita.OBJECTIVE: This study aimed to use high-resolution computed tomography scans of the chest to characterize the principal alterations occurring in cases of hydrostatic pulmonary edema. METHODS: A retrospective analysis was made of the tomography scans of 15 patients presenting clinical profiles of hydrostatic pulmonary edema. The cases were divided into five groups by etiology: congestive heart failure (n = 7; acute mitral valve disease (n = 2; acute myocardial infarction (n = 2; myocarditis (n = 2; and fibrosing mediastinitis (n = 2. RESULTS: The principal findings in the cases of hydrostatic pulmonary edema were ground-glass opacities (in 100%, interlobular septal thickening (in 100%, pleural effusion (in 87% and peribronchovascular interstitial thickening (in 80%. Other, less common

  7. FIB/SEM and SEM/EDS microstructural analysis of metal-ceramic and zirconia-ceramic interfaces.

    Science.gov (United States)

    Massimi, F; Merlati, G; Sebastiani, M; Battaini, P; Menghini, P; Bemporad, E

    2012-01-10

    Recently introduced FIB/SEM analysis in microscopy seems to provide a high-resolution characterization of the samples by 3D (FIB) cross-sectioning and (SEM) high resolution imaging. The aim of this study was to apply the FIB/SEM and SEM/EDS analysis to the interfaces of a metal-ceramic vs. two zirconia-ceramic systems. Plate samples of three different prosthetic systems were prepared in the dental lab following the manufacturers' instructions, where metal-ceramic was the result of a ceramic veneering (porcelain-fused-to-metal) and the two zirconia-ceramic systems were produced by the dedicated CAD-CAM procedures of the zirconia cores (both with final sintering) and then veneered by layered or heat pressed ceramics. In a FIB/SEM equipment (also called DualBeam), a thin layer of platinum (1 μm) was deposited on samples surface crossing the interfaces, in order to protect them during milling. Then, increasingly deeper trenches were milled by a focused ion beam, first using a relatively higher and later using a lower ion current (from 9 nA to 0.28 nA, 30KV). Finally, FEG-SEM (5KV) micrographs (1000-50,000X) were acquired. In a SEM the analysis of the morphology and internal microstructure was performed by 13KV secondary and backscattered electrons signals (in all the samples). The compositional maps were then performed by EDS probe only in the metal-ceramic system (20kV). Despite the presence of many voids in all the ceramic layers, it was possible to identify: (1) the grain structures of the metallic and zirconia substrates, (2) the thin oxide layer at the metal-ceramic interface and its interactions with the first ceramic layer (wash technique), (3) the roughness of the two different zirconia cores and their interactions with the ceramic interface, where the presence of zirconia grains in the ceramic layer was reported in two system possibly due to sandblasting before ceramic firing.

  8. A tomografia computadorizada de alta resolução na avaliação da toxicidade pulmonar por amiodarona High-resolution computed tomography of amiodarone pulmonary toxicity

    Directory of Open Access Journals (Sweden)

    Daniela Peixoto Consídera

    2006-04-01

    Full Text Available OBJETIVO: Avaliar as principais alterações identificadas na tomografia computadorizada de alta resolução do tórax em pacientes com toxicidade pulmonar pela amiodarona. MATERIAIS E MÉTODOS: Foram avaliadas dez tomografias computadorizadas de alta resolução de tórax de pacientes com pneumonite pela amiodarona, seis desses pacientes do sexo masculino e quatro do sexo feminino, com idade média de 73,5 anos. RESULTADOS: Os achados tomográficos mais relevantes foram opacidades lineares ou reticulares em seis casos (60%, pequenos nódulos com densidade elevada em seis casos (60%, consolidações densas em três casos (30% e aumento da densidade do parênquima hepático em cinco de oito casos em que havia estudo tomográfico do abdome superior (62,5%. CONCLUSÃO: A tomografia computadorizada de alta resolução é um exame importante na avaliação de pacientes com toxicidade pulmonar pela amiodarona, devendo ser realizada sempre que houver suspeita deste diagnóstico. O achado de espessamento de septos interlobulares associado a lesões com aumento de densidade é altamente sugestivo deste diagnóstico.OBJECTIVE: To evaluate the main findings of chest high-resolution computed tomography in patients with amiodarone pulmonary toxicity. MATERIALS AND METHODS: Ten patients - six male and four female, average age of 73.5 years - with amiodarone-induced pneumonitis have undergone chest high-resolution computed tomography. RESULTS: The most relevant tomographic findings were linear or reticular opacities in six cases (60%, small high density nodules in six cases (60%, dense consolidations in three cases (30% and increased density in the hepatic parenchyma in five of eight cases in which there was a superior abdomen CT scan (62.5%. CONCLUSION: The high-resolution computed tomography is a valuable non-invasive test for evaluating patients with amiodarone pulmonary toxicity and should always be performed when one suspects of the presence of this

  9. Three dimensional rock microstructures: insights from FIB-SEM tomography

    Science.gov (United States)

    Drury, Martyn; Pennock, Gill; de Winter, Matthijs

    2016-04-01

    Most studies of rock microstructures investigate two-dimensional sections or thin slices of three dimensional grain structures. With advances of X-ray and electron tomography methods the 3-D microstructure can be(relatively) routinely investigated on scales from a few microns to cm. 3D studies are needed to investigate the connectivity of microstructures and to test the assumptions we use to calculate 3D properties from 2D sections. We have used FIB-SEM tomography to study the topology of melts in synthetic olivine rocks, 3D crystal growth microstructures, pore networks and subgrain structures. The technique uses a focused ion beam to make serial sections with a spacing of tens to hundreds of nanometers. Each section is then imaged or mapped using the electron beam. The 3D geometry of grains and subgrains can be investigated using orientation contrast or EBSD mapping. FIB-SEM tomography of rocks and minerals can be limited by charging of the uncoated surfaces exposed by the ion beam. The newest generation of FIB-SEMs have much improved low voltage imaging capability allowing high resolution charge free imaging. Low kV FIB-SEM tomography is now widely used to study the connectivity of pore networks. In-situ fluids can also be studied using cryo-FIB-SEM on frozen samples, although special freezing techniques are needed to avoid artifacts produced by ice crystallization. FIB-SEM tomography is complementary, in terms of spatial resolution and sampled volume, to TEM tomography and X-ray tomography, and the combination of these methods can cover a wide range of scales. Our studies on melt topology in synthetic olivine rocks with a high melt content show that many grain boundaries are wetted by nanometre scale melt layers that are too thin to resolve by X-ray tomography. A variety of melt layer geometries occur consistent with several mechanisms of melt layer formation. The nature of melt geometries along triple line junctions and quadruple points can be resolved

  10. Critical factors in SEM 3D stereo microscopy

    International Nuclear Information System (INIS)

    Marinello, F; Savio, E; Bariani, P; Horsewell, A; De Chiffre, L

    2008-01-01

    This work addresses dimensional measurements performed with the scanning electron microscope (SEM) using 3D reconstruction of surface topography through stereo-photogrammetry. The paper presents both theoretical and experimental investigations, on the effects of instrumental variables and measurement parameters on reconstruction accuracy. Investigations were performed on a novel sample, specifically developed and implemented for the tests. The description is based on the model function introduced by Piazzesi and adapted for eucentrically tilted stereopairs. Two main classes of influencing factors are recognized: the first one is related to the measurement operation and the instrument set-up; the second concerns the quality of scanned images and represents the major criticality in the application of SEMs for 3D characterizations

  11. Three dimensional imaging of surface geometry in SEM

    International Nuclear Information System (INIS)

    Slowko, W.

    1997-01-01

    A great advantage of scanning electron microscopy (SEM) is its ability of the surface topography in the way as a human eye is accustomed to see lights and shadows on macroobjects. However, SEM's can hardly display vertical dimensions of the structures. One of possible solutions is reconstruction of the surface profiles by directional detection of secondary electrons and proper signal processing. However, the surface profile still gives two dimensional information and the method should be extended to obtain fully three dimensional imaging. The extension consists in a simultaneous reconstruction of the surface profiles in two perpendicular directions (x and y) and their superposition. The solution proposed is based on a quadrupole detector system and a computer or analogue system for signal processing. Quantitative data of the surface topography can be displayed in many manners in the system of two or three co-ordinates with use of pseudo-colour for the altitude coding. (author)

  12. SEM and Raman studies of CNT films on porous Si

    Science.gov (United States)

    Belka, R.; Keczkowska, J.; Suchańska, M.; Firek, P.; Wronka, H.; Kozłowski, M.; Radomska, J.; Czerwosz, E.; Craciunoiu, F.

    2017-08-01

    Carbon nanotube (CNT) films deposited on different porous silica substrates were studied by Scanning Electron Microscopy (SEM) and Raman Spectroscopy (RS). The films samples were prepared by a two-step method consisting of PVD and CVD processes. In the first step the nanocomposite Ni-C film was obtained by evaporation in dynamic vacuum from two separated sources of fullerenes and nickel acetate. Those films were deposited on porous silica and DLC/porous silica substrates. Analysis of SEM imaging showed that the obtained film are composed of carbon nanotubes, the distribution, size and quality of which depend on the type of substrate. The CNT films were studied by RS method to determine the influence of the substrate type on disordering of carbonaceous structure and quality of CNT in deposited films.

  13. Repetitive Observation of Coniferous Samples in ESEM and SEM

    Czech Academy of Sciences Publication Activity Database

    Tihlaříková, Eva; Neděla, Vilém

    2015-01-01

    Roč. 21, S3 (2015), s. 1695-1696 ISSN 1431-9276 R&D Projects: GA ČR(CZ) GA14-22777S; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : SEM * ESEM * biological samples * repetitive observation Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.730, year: 2015

  14. Characterization of some biological specimens using TEM and SEM

    Science.gov (United States)

    Ghosh, Nabarun; Smith, Don W.

    2009-05-01

    The advent of novel techniques using the Transmission and Scanning Electron Microscopes improved observation on various biological specimens to characterize them. We studied some biological specimens using Transmission and Scanning Electron Microscopes. We followed negative staining technique with Phosphotungstic acid using bacterial culture of Bacillus subtilis. Negative staining is very convenient technique to view the structural morphology of different samples including bacteria, phage viruses and filaments in a cell. We could observe the bacterial cell wall and flagellum very well when trapped the negative stained biofilm from bacterial culture on a TEM grid. We cut ultra thin sections from the fixed root tips of Pisum sativum (Garden pea). Root tips were pre fixed with osmium tetroxide and post fixed with uranium acetate and placed in the BEEM capsule for block making. The ultrathin sections on the grid under TEM showed the granular chromatin in the nucleus. The protein bodies and large vacuoles with the storage materials were conspicuous. We followed fixation, critical point drying and sputter coating with gold to view the tissues with SEM after placing on stubs. SEM view of the leaf surface of a dangerous weed Tragia hispida showed the surface trichomes. These trichomes when break on touching releases poisonous content causing skin irritation. The cultured tissue from in vitro culture of Albizia lebbeck, a tree revealed the regenerative structures including leaf buds and stomata on the tissue surface. SEM and TEM allow investigating the minute details characteristic morphological features that can be used for classroom teaching.

  15. Surface characteristics of isopod digestive gland epithelium studied by SEM.

    Science.gov (United States)

    Millaku, Agron; Leser, Vladka; Drobne, Damjana; Godec, Matjaz; Torkar, Matjaz; Jenko, Monika; Milani, Marziale; Tatti, Francesco

    2010-05-01

    The structure of the digestive gland epithelium of a terrestrial isopod Porcellio scaber has been investigated by conventional scanning electron microscopy (SEM), focused ion beam-scanning electron microscopy (FIB/SEM), and light microscopy in order to provide evidence on morphology of the gland epithelial surface in animals from a stock culture. We investigated the shape of cells, extrusion of lipid droplets, shape and distribution of microvilli, and the presence of bacteria on the cell surface. A total of 22 animals were investigated and we found some variability in the appearance of the gland epithelial surface. Seventeen of the animals had dome-shaped digestive gland "normal" epithelial cells, which were densely and homogeneously covered by microvilli and varying proportions of which extruded lipid droplets. On the surface of microvilli we routinely observed sparsely distributed bacteria of different shapes. Five of the 22 animals had "abnormal" epithelial cells with a significantly altered shape. In three of these animals, the cells were much smaller, partly or completely flat or sometimes pyramid-like. A thick layer of bacteria was detected on the microvillous border, and in places, the shape and size of microvilli were altered. In two animals, hypertrophic cells containing large vacuoles were observed indicating a characteristic intracellular infection. The potential of SEM in morphological investigations of epithelial surfaces is discussed.

  16. Analysis of microtraces in invasive traumas using SEM/EDS.

    Science.gov (United States)

    Vermeij, E J; Zoon, P D; Chang, S B C G; Keereweer, I; Pieterman, R; Gerretsen, R R R

    2012-01-10

    Scanning electron microscopy in combination with energy-dispersive X-ray spectrometry (SEM/EDS) is a proven forensic tool and has been used to analyze several kinds of trace evidence. A forensic application of SEM/EDS is the examination of morphological characteristics of tool marks that tools and instruments leave on bone. The microtraces that are left behind by these tools and instruments on the bone are, however, often ignored or not noticed at all. In this paper we will describe the use of SEM/EDS for the analysis of microtraces in invasive sharp-force, blunt-force and bone-hacking traumas in bone. This research is part of a larger multi-disciplinary approach in which pathologists, forensic anthropologists, toolmark and microtrace experts work together to link observed injuries to a suspected weapon or, in case of an unknown weapon, to indicate a group of objects that could have been used as a weapon. Although there are a few difficulties one have to consider, the method itself is rather simple and straightforward to apply. A sample of dry and clean bone is placed into the SEM sample chamber and brightness and contrast are set such that bone appears grey, metal appears white and organic material appears black. The sample is then searched manually to find relevant features. Once features are found their elemental composition is measured by an energy dispersive X-ray spectrometer (EDS). This method is illustrated using several cases. It is shown that SEM/EDS analysis of microtraces in bone is a valuable tool to get clues about an unknown weapon and can associate a specific weapon with injuries on the basis of appearance and elemental composition. In particular the separate results from the various disciplines are complementary and may be combined to reach a conclusion with a stronger probative value. This is not only useful in the courtroom but above all in criminal investigations when one have to know for what weapon or object to look for. Copyright © 2011

  17. Achados de tomografia computadorizada de alta resolução em pneumonia pelo vírus parainfluenza pós-transplante de medula óssea: relato de caso

    Directory of Open Access Journals (Sweden)

    Emerson L. Gasparetto

    2004-11-01

    Full Text Available RESUMO: Paciente feminina, de 19 anos, transplantada de medula óssea devido a leucemia mielóide crónica, apresentando tosse seca e coriza no 67.º dia após o procedimento. A radiografia de tórax não evidenciou alterações. A tomografia computadorizada de alta resolução do tórax revelou consolidação subsegmentar na periferia do lobo inferior esquerdo e áreas de redução da atenuação nos terços superior e médio dos pulmões. O lavado broncoalveolar demonstrou pesquisa positiva por imunoflorescência direta para anticorpos anti-vírus parainfluenza. Foi instituído tratamento com ribavirina aerolizada durante 10 dias, havendo melhoria clínico-radiológica do quadro infeccioso.REV PORT PNEUMOL 2004; X (6: 485-489 ABSTRACT: Nineteen year-old female patient, who underwent bone marrow transplantation because of chronic myelogenous leukemia, presented with dry cough and coriza sixty-seven days after the procedure. The chest radiograph was normal. The high resolution computed tomography showed a subsegmental air-space consolidation at the periphery of the left inferior lobe and areas of low attenuation at the superior and middle lung zones. The bronchoalveolar lavage demonstrated positive direct fluorescence antibody testing against parainfluenza virus. Treatment with aerolizated ribavirin was instituted during 10 days and the patient showed clinical-radiological improvement.REV PORT PNEUMOL 2004; X (6: 485-489 Palavras-chave: Vírus parainfluenza, tomografia computadorizada de alta resolução, transplante de medula óssea, Key-words: Parainfluenza virus, high resolution computed tomography, bone marrow transplantation

  18. Uso de manometria computadorizada para estudo do espasmo do segmento faringoesofágico em pacientes com voz traqueoesofágica inadequada antes e após aplicação de toxina botulínica Computerized manometry use to evaluate spasm in pharyngoesophageal segment in patients with poor tracheoesophageal speech before and after treatment with botulinum toxin

    Directory of Open Access Journals (Sweden)

    Carlos T. Chone

    2009-04-01

    Full Text Available Voz traqueoesofágica (VTE com prótese fonatória (PF é método eficaz e reproduzível na reabilitação vocal após laringectomia total (LT, impedida pelo espasmo do segmento faringoesofágico (SFE. A manometria computadorizada (MC é novo método objetivo e direto de avaliação do SFE. OBJETIVO: Análise objetiva do espasmo do SFE, com MC, antes e após aplicação de toxina botulínica (TB. DESENHO DO ESTUDO: Prospectivo clínico. MATERIAL E MÉTODOS: Análise de oito pacientes consecutivos submetidos à LT com VTE e PF, sem emissão vocal, com espasmo do SFE à videofluoroscopia, considerado padrão ouro para detecção de espasmo. Todos trataram o espasmo com injeção de 100 unidades de TB no SFE. Avaliação constituiu-se de videofluoroscopia e MC do SFE, antes e após aplicação de TB. RESULTADOS: Houve diminuição na pressão do SFE à MC, após injeção de TB em todos. A média de pressão do SFE à MC, nos oito pacientes, antes da aplicação de TB foi de 25.36 mmHg e após foi de 14.31 mmHg (p=0,004. Houve emissão vocal sem esforço e melhora do espasmo do SFE à videofluoroscopia após o uso da TB. CONCLUSÃO: Foi observada diminuição na pressão do SFE após injeção da TB à MC em todos os pacientes, com melhora do espasmo à videofluoroscopia.Tracheoesophageal voice (TEV with voice prosthesis (VP is an efficient and reproducible method used in vocal rehabilitation after total laryngectomy (TL, prevented by spasms in the pharyngoesophageal segment (PES. Computerized Manometry (CM is a new, direct and objective method used to assess the PES. AIM: to carry out an objective analysis of the PES, with CM, before and after the injection of botulinum toxin (BT. STUDY DESIGN: clinical-prospective. MATERIALS AND METHODS: analysis of eight patients consecutively submitted to TL with TEV and VP, without vocal emission, with PES spasms seen through videofluoroscopy, considered the gold standard for spasm detection. All had their

  19. Classification and printability of EUV mask defects from SEM images

    Science.gov (United States)

    Cho, Wonil; Price, Daniel; Morgan, Paul A.; Rost, Daniel; Satake, Masaki; Tolani, Vikram L.

    2017-10-01

    Classification and Printability of EUV Mask Defects from SEM images EUV lithography is starting to show more promise for patterning some critical layers at 5nm technology node and beyond. However, there still are many key technical obstacles to overcome before bringing EUV Lithography into high volume manufacturing (HVM). One of the greatest obstacles is manufacturing defect-free masks. For pattern defect inspections in the mask-shop, cutting-edge 193nm optical inspection tools have been used so far due to lacking any e-beam mask inspection (EBMI) or EUV actinic pattern inspection (API) tools. The main issue with current 193nm inspection tools is the limited resolution for mask dimensions targeted for EUV patterning. The theoretical resolution limit for 193nm mask inspection tools is about 60nm HP on masks, which means that main feature sizes on EUV masks will be well beyond the practical resolution of 193nm inspection tools. Nevertheless, 193nm inspection tools with various illumination conditions that maximize defect sensitivity and/or main-pattern modulation are being explored for initial EUV defect detection. Due to the generally low signal-to-noise in the 193nm inspection imaging at EUV patterning dimensions, these inspections often result in hundreds and thousands of defects which then need to be accurately reviewed and dispositioned. Manually reviewing each defect is difficult due to poor resolution. In addition, the lack of a reliable aerial dispositioning system makes it very challenging to disposition for printability. In this paper, we present the use of SEM images of EUV masks for higher resolution review and disposition of defects. In this approach, most of the defects detected by the 193nm inspection tools are first imaged on a mask SEM tool. These images together with the corresponding post-OPC design clips are provided to KLA-Tencor's Reticle Decision Center (RDC) platform which provides ADC (Automated Defect Classification) and S2A (SEM

  20. A simplified method for scanning electron microscopy (SEM) autoradiography

    International Nuclear Information System (INIS)

    Shahar, A.; Lasher, R.

    1980-01-01

    The combination of autoradiography with SEM provides a valuable tool for the study of labeled biological materials, but the previously described methods are complicated because they call first for the removal of gelatin from the film emulsion and this is then followed by deposition of gold vapor on the specimen. The authors describe a much simpler method which can easily be adapted to routine examination of cell cultures. In this method, gelatin is not removed; the film is coated with vaporized carbon only. This procedure permits visualization of both cellular image and distribution of silver grains. (Auth.)

  1. La semántica en la Web

    OpenAIRE

    Roger, Sandra

    2004-01-01

    El propósito de este trabajo es presentar la motivación de nuestra línea de investigación, metas y desarrollos futuros. Fundamentalmente, nuestro interés se centrará en poder capturar el potencial de las técnicas y paradigmas basadas en conocimiento semántico para la representación de conocimiento, la localización, compartición e integración de recursos a mediante la WWW.

  2. XRD and SEM study of alumina silicate porcelain insulator

    Science.gov (United States)

    Duddi, Dharmender; Singh, G. P.; Kalra, Swati; Shekhawat, M. S.; Tak, S. K.

    2018-05-01

    Higher strength electrical porcelain is a requirement of industry. This will be achieved by a specific composition of raw materials, which is consisted of clays and feldspars. Water absorption, particle size and insulating properties are of special interest now a day. China clay, Ball clay and Quartz are widely used by ceramic industries in Bikaner district of Rajasthan. Sample for present study were prepared by mixing of above clay, feldspar with MnO2, then shrinkage is observed. Bar shaped samples were prepared and heated up to a temperature of about 1185° C to observe shrinkage. For phase study of XRD and SEM are observed.

  3. Developing 3D SEM in a broad biological context

    Science.gov (United States)

    Kremer, A; Lippens, S; Bartunkova, S; Asselbergh, B; Blanpain, C; Fendrych, M; Goossens, A; Holt, M; Janssens, S; Krols, M; Larsimont, J-C; Mc Guire, C; Nowack, MK; Saelens, X; Schertel, A; Schepens, B; Slezak, M; Timmerman, V; Theunis, C; Van Brempt, R; Visser, Y; GuÉRin, CJ

    2015-01-01

    When electron microscopy (EM) was introduced in the 1930s it gave scientists their first look into the nanoworld of cells. Over the last 80 years EM has vastly increased our understanding of the complex cellular structures that underlie the diverse functions that cells need to maintain life. One drawback that has been difficult to overcome was the inherent lack of volume information, mainly due to the limit on the thickness of sections that could be viewed in a transmission electron microscope (TEM). For many years scientists struggled to achieve three-dimensional (3D) EM using serial section reconstructions, TEM tomography, and scanning EM (SEM) techniques such as freeze-fracture. Although each technique yielded some special information, they required a significant amount of time and specialist expertise to obtain even a very small 3D EM dataset. Almost 20 years ago scientists began to exploit SEMs to image blocks of embedded tissues and perform serial sectioning of these tissues inside the SEM chamber. Using first focused ion beams (FIB) and subsequently robotic ultramicrotomes (serial block-face, SBF-SEM) microscopists were able to collect large volumes of 3D EM information at resolutions that could address many important biological questions, and do so in an efficient manner. We present here some examples of 3D EM taken from the many diverse specimens that have been imaged in our core facility. We propose that the next major step forward will be to efficiently correlate functional information obtained using light microscopy (LM) with 3D EM datasets to more completely investigate the important links between cell structures and their functions. Lay Description Life happens in three dimensions. For many years, first light, and then EM struggled to image the smallest parts of cells in 3D. With recent advances in technology and corresponding improvements in computing, scientists can now see the 3D world of the cell at the nanoscale. In this paper we present the

  4. Sexual Arousal and Sexually Explicit Media (SEM): Comparing Patterns of Sexual Arousal to SEM and Sexual Self-Evaluations and Satisfaction Across Gender and Sexual Orientation.

    Science.gov (United States)

    Hald, Gert Martin; Stulhofer, Aleksandar; Lange, Theis

    2018-03-01

    Investigations of patterns of sexual arousal to certain groups of sexually explicit media (SEM) in the general population in non-laboratory settings are rare. Such knowledge could be important to understand more about the relative specificity of sexual arousal in different SEM users. (i) To investigate whether sexual arousal to non-mainstream vs mainstream SEM contents could be categorized across gender and sexual orientation, (ii) to compare levels of SEM-induced sexual arousal, sexual satisfaction, and self-evaluated sexual interests and fantasies between non-mainstream and mainstream SEM groups, and (iii) to explore the validity and predictive accuracy of the Non-Mainstream Pornography Arousal Scale (NPAS). Online cross-sectional survey of 2,035 regular SEM users in Croatia. Patterns of sexual arousal to 27 different SEM themes, sexual satisfaction, and self-evaluations of sexual interests and sexual fantasies. Groups characterized by sexual arousal to non-mainstream SEM could be identified across gender and sexual orientation. These non-mainstream SEM groups reported more SEM use and higher average levels of sexual arousal across the 27 SEM themes assessed compared with mainstream SEM groups. Only few differences were found between non-mainstream and mainstream SEM groups in self-evaluative judgements of sexual interests, sexual fantasies, and sexual satisfaction. The internal validity and predictive accuracy of the NPAS was good across most user groups investigated. The findings suggest that in classified non-mainstream SEM groups, patterns of sexual arousal might be less fixated and category specific than previously assumed. Further, these groups are not more judgmental of their SEM-related sexual arousal patterns than groups characterized by patterns of sexual arousal to more mainstream SEM content. Moreover, accurate identification of non-mainstream SEM group membership is generally possible across gender and sexual orientation using the NPAS. Hald GM

  5. Sem-edx and ftir studies of chlorinated rubber coating

    International Nuclear Information System (INIS)

    Bano, H.; Khan, M.I.

    2013-01-01

    Summary: Anticorrosive performance of chlorinated rubber coating has been investigated by visual examination, Scanning electron microscopy (SEM)/Energy dispersive X-ray (EDX) analysis and Fourier transform infrared (FTIR) spectroscopy. After surface preparation, commercially available coating system based on chlorinated rubber (primer)/chlorinated rubber (topcoat) formulation was applied on mild steel test panels (10cm x 15cm sizes). Prepared coated panels were exposed at marine, industrial and urban test sites located in Karachi, Pakistan according to ISO 8565 norm. Accelerated testing was performed by using a salt spray chamber (ASTM B117 norm). Accelerated weathering methods are the methods in which the factors responsible for the degradation of coatings are artificially intensified in order to achieve the rapid degradation of coatings. Visual examination of blistering and rusting as well as SEM micrographs indicated a more severe degradation of the coating surface characteristics at natural exposure testing sites (particularly at marine test site) than for accelerated (salt spray) testing. EDX determination of the Oxygen/Carbon (O/C) ratios also indicated increased degradation at natural test sites compared to the accelerated (salt spray) testing. Photooxidation of the binder results in the formation of carbonyl compounds as revealed by FTIR spectroscopy which also indicated dehydrochlorination. (author)

  6. Comparative SEM analysis of nine F22 aligner cleaning strategies.

    Science.gov (United States)

    Lombardo, Luca; Martini, Marco; Cervinara, Francesca; Spedicato, Giorgio Alfredo; Oliverio, Teresa; Siciliani, Giuseppe

    2017-12-01

    The orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible. There are several advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures. Five patients were each given a series of F22 aligners, each to be worn for 14 days and nights, with the exception of meal and brushing times. Patients were instructed to clean each aligner using a prescribed strategy, and sections of the used aligners were observed under SEM. One grey-scale SEM image was saved per aligner in JPEG format with an 8-bit colour depth, and a total of 45 measurements on the grey scale ("Value" variable) were made. This dataset was analysed statistically via repeated measures ANOVA to determine the effect of each of the nine cleaning strategies in each of the five patients. A statistically significant difference in the efficacy of the cleaning strategies was detected. Specifically, rinsing with water alone was significantly less efficacious, and a combination of cationic detergent solution and ultrasonication was significantly more efficacious than the other methods (p aligners.

  7. Diferenciador semántico: bipolaridad del espacio semántico, un problema de medida del significado

    OpenAIRE

    Álvarez C., Ramiro

    2012-01-01

    En relación con el supuesto de bipolaridad y su aspecto recíprocamente antagónico, Osgood y otros (1957) han ligado su modelo de espacio semántico a la teoría del aprendizaje. Plantean la hipótesis de que cierto estimulo externo, o signo, desencadena un proceso mediacional interno (nn) el cual se constituye en emisor de estímulos (rm 15m). Este es el rm mediacional que contendría el significado del signo. La teoría de mediación la relacionan con el supuesto de bipolaridad en los siguientes té...

  8. Comparing the detection of iron-based pottery pigment on a carbon-coated sherd by SEM-EDS and by Micro-XRF-SEM.

    Science.gov (United States)

    Pendleton, Michael W; Washburn, Dorothy K; Ellis, E Ann; Pendleton, Bonnie B

    2014-03-01

    The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SEM maps but was applied to maintain an unbiased comparison between the systems. The Micro-XRF-SEM analysis was capable of lower limits of detection than that of the SEM-EDS system, and therefore the Micro-XRF-SEM system could produce elemental maps of elements not easily detected by SEM-EDS mapping systems. Because SEM-EDS and Micro-XRF-SEM have been used for imaging and chemical analysis of biological samples, this comparison of the detection systems should be useful to biologists, especially those involved in bone or tooth (hard tissue) analysis.

  9. SEM investigation of incandescent lamp mantle structure on durability

    International Nuclear Information System (INIS)

    Gerneke, D.; Lang, C.

    2002-01-01

    Full text: The incandescent mantle as used on pressure and non-pressure liquid fuel lamps has been in use for over 100 years. What remains unexplained is the way in which the resistance to mechanical shock and the decline in tensile strength with usage is experienced. It has been suggested that to improve durability it is necessary to continuously burn a new mantle for the first two to three hours. The known factors in mantle durability and mechanical strength are chemical composition and fabric weave. This study was undertaken to investigate the effects of burning time and temperature on thorium oxide mantles. The operating temperature of mantles on a range of kerosene pressure lamps was measured and found to be between 800 and 1100 deg C. Heat treatments of thorium based Coleman mantles were carried out in a laboratory furnace within these ranges of temperatures for periods ranging from 2 minutes to 2 hours. The mantles were then viewed in a LEO S440 analytical SEM. Results at 800 deg C show a distinct change in surface morphology with increasing exposure time. At the shorter times (2-5 minutes) the surface was relatively smooth. With increased time periods (15 - 120 minutes) the surface was observed to have a large lumpy structure. At 1100 deg C the difference in surface morphology was not apparent between the shortest and longest times. The surface appears much smoother and no lumpy structure was observed. This suggests that when a mantle is operated at the higher temperature of 1100 deg C the structure of the Thorium oxide is quickly transformed into the known stronger amorphous form. This is taken as the observed smooth structure seen in the SEM images of the 1100 deg C samples. Thus the mantle is expected to be more resistant to mechanical shock and have increased durability. Practical field test results confirm these observations. The mantle on a lamp that is operating efficiently, burns brightly, will far outlast a mantle on an inefficient lamp which bums

  10. Cultivo sem solo do morangueiro Strawberry soilless cultivation

    Directory of Open Access Journals (Sweden)

    Gustavo Giménez

    2008-02-01

    Full Text Available O morangueiro é uma cultura importante em vários países, principalmente nos Estados Unidos e na Europa, por suas características sensoriais, propriedades nutritivas e por sua rentabilidade. O cultivo comercial sem solo de morangueiro está bem desenvolvido na Europa, onde tem permitido um aumento da produtividade e qualidade da produção assim como a ampliação da oferta do produto ao longo do ano. Predomina o sistema aberto, em sacolas ou vasos com diferentes tipos de substratos, utilizando-se densidades de 8 a 12plantas m-2. As produtividades obtidas estão entre 5 e 10kg m-2. Para isolar as plantas do solo e facilitar o manejo da cultura, os vasos ou sacolas são suspensos a uma altura entre 0,8 e 1m da superfície do solo. A composição da solução nutritiva é variável, refletindo as diferentes condições produtivas. As mudas são produzidas principalmente em bandejas com substrato, a partir de pontas de estolões obtidas da multiplicação de plantas matrizes provenientes da propagação in vitro. No Brasil, o cultivo sem solo de morangueiro é ainda incipiente e os resultados produtivos e econômicos têm sido insatisfatórios, principalmente por falta de informações de pesquisas capazes de indicar sistemas apropriados de cultivo para as condições locais. É necessário desenvolver sistemas sustentáveis, preferencialmente fechados, combinando alta produtividade e elevada eficiência de utilização da água e dos nutrientes. No presente trabalho, são revisados os principais aspectos da produção em sistemas de cultivo sem solo de mudas e fruta de morangueiro. São descritos a produção de mudas, os sistemas e as soluções nutritivas empregadas em diferentes países. Ao final, são feitas inferências sobre a possibilidade de adoção e geração do sistema de cultivo sem solo apropriado para as condições brasileiras.Strawberry is a very important crop in Europe and USA due to its nutritional and sensorial

  11. Filler segmentation of SEM paper images based on mathematical morphology.

    Science.gov (United States)

    Ait Kbir, M; Benslimane, Rachid; Princi, Elisabetta; Vicini, Silvia; Pedemonte, Enrico

    2007-07-01

    Recent developments in microscopy and image processing have made digital measurements on high-resolution images of fibrous materials possible. This helps to gain a better understanding of the structure and other properties of the material at micro level. In this paper SEM image segmentation based on mathematical morphology is proposed. In fact, paper models images (Whatman, Murillo, Watercolor, Newsprint paper) selected in the context of the Euro Mediterranean PaperTech Project have different distributions of fibers and fillers, caused by the presence of SiAl and CaCO3 particles. It is a microscopy challenge to make filler particles in the sheet distinguishable from the other components of the paper surface. This objectif is reached here by using switable strutural elements and mathematical morphology operators.

  12. Elevated temperature transmission Kikuchi diffraction in the SEM

    DEFF Research Database (Denmark)

    Fanta, Alice Bastos; Todeschini, Matteo; Burrows, Andrew

    2018-01-01

    heating associated with this system enables reliable TKD measurements at elevated temperatures without notable disturbance from infrared radiation. The dewetting of an Au thin film into Au nanoparticles upon heating is followed with orientation mapping in a temperature range between 20 °C and 900 °C....... The local thickness variation associated with the dewetting is observed qualitatively by observing the intensity of the transmitted beam, which decreases as the film thickness increases locally. The results of this study reveal that TKD is a well suited technique to study thin-film stability and solid state...... dewetting. Moreover, the outcome of this methodological study provides a baseline for further in-situ crystallographic studies of electron transparent samples in the SEM....

  13. Afasia global sem hemiparesia: AVC ou transtorno conversivo?

    OpenAIRE

    Negreiros,Daniel Philippi de; Fregni,Felipe; Scalco,Andréia Zavaloni

    2007-01-01

    CONTEXTO: A realização de diagnóstico neurológico e psiquiátrico em ambiente de emergência hospitalar com freqüência é uma tarefa complexa e exige colaboração interdisciplinar. Um dos diagnósticos diferenciais de doenças neurológicas é o transtorno conversivo, cuja característica principal é a presença de sintomas afetando funções motoras ou sensoriais, que sugerem desordem clínica ou neurológica, porém sem doença orgânica subjacente que explique o quadro. RELATO DE CASO: Os autores relatam o...

  14. SEM-EDX--a useful tool for forensic examinations

    International Nuclear Information System (INIS)

    Zadora, G.; Brozek-Mucha, Z.

    2003-01-01

    There are two main aims of forensic examination of the physical evidences. The first aim is comparison of the evidence with the reference material (called discrimination). The task is to find out whether they could have come from the same object. The second aim, when there is no comparative material available, is a classification of the evidence sample into a group of objects taking into account its specific chemical and physical properties. Scanning electron microscopy with energy dispersive X-ray spectrometry (SEM-EDX) is a powerful tool for forensic scientists to classify and discriminate evidence material because they can simultaneously examine the morphology and the elemental composition of objects. Moreover, the obtained results could be enhanced using some methods of chemometric analysis. A few examples of problems related to the classification and discrimination of selected types of microtraces are presented

  15. Comparative SEM analysis of nine F22 aligner cleaning strategies

    Directory of Open Access Journals (Sweden)

    Luca Lombardo

    2017-09-01

    Full Text Available Abstract Background The orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible. There are several advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures. Methods Five patients were each given a series of F22 aligners, each to be worn for 14 days and nights, with the exception of meal and brushing times. Patients were instructed to clean each aligner using a prescribed strategy, and sections of the used aligners were observed under SEM. One grey-scale SEM image was saved per aligner in JPEG format with an 8-bit colour depth, and a total of 45 measurements on the grey scale (“Value” variable were made. This dataset was analysed statistically via repeated measures ANOVA to determine the effect of each of the nine cleaning strategies in each of the five patients. Results A statistically significant difference in the efficacy of the cleaning strategies was detected. Specifically, rinsing with water alone was significantly less efficacious, and a combination of cationic detergent solution and ultrasonication was significantly more efficacious than the other methods (p < 0.05. Conclusions Of the nine cleaning strategies examined, only that involving 5 min of ultrasonication at 42 k Hz combined with a 0.3% germicidal cationic detergent was observed to be statistically effective at removing the bacterial biofilm from the surface of F22 aligners.

  16. Willis PM 10-2.5 Precision Results, pdf has summary table and SEM images

    Data.gov (United States)

    U.S. Environmental Protection Agency — Precision data from the SEM and SEM images from the samples. This dataset is associated with the following publication: Peters, T., E. Sawvel, R. Willis, R. West,...

  17. Proposta para padronização do relatório de tomografia computadorizada nos aneurismas da aorta abdominal A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Fabiola Goda Torlai

    2006-08-01

    Full Text Available OBJETIVO: Propor um modelo de padronização de relatório para aneurisma da aorta abdominal na tomografia computadorizada. MATERIAIS E MÉTODOS: Foram realizadas, no período de abril a outubro de 2004, entrevistas com integrantes da Disciplina de Cirurgia Vascular da nossa instituição, para elaboração de um modelo de padronização de relatório de tomografia computadorizada para o estudo do aneurisma da aorta abdominal. A partir deste modelo foi elaborado um questionário, enviado a nove outros cirurgiões, todos com experiência em cirurgia da aorta abdominal. O índice de resposta aos questionários foi de 55,5% (5/9. RESULTADOS: Os parâmetros de interesse citados mais freqüentemente para a avaliação dos aneurismas de aorta abdominal foram: diâmetro máximo do colo proximal, extensão do colo proximal até a artéria renal mais baixa, forma do colo proximal, diâmetro máximo do aneurisma e diâmetro das artérias ilíacas comuns. Estes dados permitiram elaborar uma proposta de modelo para padronização de relatório na tomografia computadorizada. CONCLUSÃO: Um modelo para a análise tomográfica padronizada do aneurisma de aorta abdominal permite atender às necessidades dos cirurgiões vasculares para acompanhar a evolução e planejar o tratamento destes pacientes.OBJECTIVE: To propose a model to standardize computed tomography reports on abdominal aortic aneurysms. MATERIALS AND METHODS: Interviews were carried out with members of Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9. RESULTS: The most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms

  18. Fibrose maciça progressiva em trabalhadores expostos à sílica: achados na tomografia computadorizada de alta resolução Progressive massive fibrosis in silica-exposed workers: high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Ângela Santos Ferreira

    2006-12-01

    Full Text Available OBJETIVO: Avaliar as características radiológicas das massas conglomeradas pela tomografia computadorizada de alta resolução de tórax. MÉTODOS: Foram selecionados 75 pacientes silicóticos, a maioria jateadores de areia, portadores de fibrose maciça progressiva, atendidos no Hospital Universitário Antônio Pedro entre 1986 e 2004. Os pacientes foram submetidos a avaliação clínica, radiografia simples de tórax e tomografia computadorizada de alta resolução. RESULTADOS: Mais da metade dos pacientes com silicose complicada mostrou na radiografia de tórax grandes opacidades dos tipos B e C, denotando a gravidade da doença nesses pacientes. Dos 75 casos, apenas um apresentou massa unilateral simulando câncer de pulmão. Quarenta e quatro pacientes realizaram tomografia computadorizada de alta resolução do tórax. As massas predominaram nos terços superiores e posteriores (88,6%. Broncograma aéreo e calcificações no interior das massas foram observados em 70,4% e 63,8% dos casos, respectivamente. História de tuberculose foi relatada em 52% dos pacientes estudados. CONCLUSÃO: Na grande maioria dos casos as massas eram bilaterais, predominando nas regiões póstero-superiores dos pulmões, com broncogramas aéreos e calcificações de permeio. Associação com calcificações linfonodais foi um achado freqüente. A exposição a elevadas concentrações de poeira e a tuberculose foram consideradas fatores de risco para o desenvolvimento da fibrose maciça progressiva.OBJECTIVE: To evaluate the radiological characteristics of conglomerate masses using high-resolution computed tomography of the chest. METHODS: From among the patients treated between 1986 and 2004 at the Antonio Pedro University Hospital, 75 patients with silicosis and massive fibrosis, most working in the field of sandblasting, were selected for study. These patients were submitted to a clinical evaluation, chest X-ray and high-resolution computed tomography of

  19. Análise de carcinomas epidermóides por meio de radiografia panorâmica e tomografia computadorizada Analysis of squamous cell carcinomas by means of panoramic radiography and computed tomography

    Directory of Open Access Journals (Sweden)

    Amanda Cáceres PEREIRA

    2001-12-01

    Full Text Available Este trabalho teve como objetivo correlacionar aspectos radiográficos como, localização e extensão do tumor, infiltração óssea e de tecidos moles e destruição das corticais, obtidos nas radiografias panorâmicas com os encontrados nas tomografias computadorizadas (TCs. Os aspectos radiográficos de 48 pacientes com diagnóstico histopatológico de carcinomas epidermóides, localizados em várias regiões do complexo buco-maxilo-facial, foram analisados por 4 radiologistas. As radiografias panorâmicas e as tomografias computadorizadas foram realizadas nos hospitais e clínicas da Universidade de Iowa (EUA, FUNDECTO - USP e Hospital Universitário da Universidade de São Paulo (SP, Brasil. Como resultados, obtivemos a grande limitação da radiografia panorâmica em determinar a localização e extensão do tumor, com delimitações bastante imprecisas da lesão. Já as TCs ofereceram resultados mais direcionados como: invasão do tumor em direção a estruturas moles adjacentes, extensão da destruição óssea, bem como a profundidade da lesão, que foram confirmados com os achados cirúrgicos. Concluímos que a tomografia computadorizada demonstrou ser uma técnica bastante sensível na detecção do comprometimento ósseo e do envolvimento de tecidos moles, proporcionando, assim, o auxílio no diagnóstico e no planejamento do tratamento. No entanto, a radiografia panorâmica foi muito pouco sensível e eficaz, por mostrar apenas margens imprecisas e pouco nítidas da lesão, não avaliando o envolvimento de tecidos moles.The purpose of this work was to compare radiographic findings, such as localization and extension of tumors toward the bone and soft tissues, in panoramic radiography and computed tomography (CT. Four radiologists assessed the radiographic findings of 48 patients with the histopathological diagnosis of squamous cell carcinoma in different sites of the maxillofacial region. Panoramic radiographs and computed

  20. Quantificação computadorizada dos índices de placa e cálculo dentais da imagem digital da superfície vestibular dos dentes de cães

    Directory of Open Access Journals (Sweden)

    Samira L. Abdalla

    2009-08-01

    Full Text Available A doença periodontal é causada pelo acúmulo de placa bacteriana sobre os dentes e estruturas adjacentes. Para sua mensuração têm sido formulados índices que consideram a quantidade e intensidade de placa bacteriana (PB e de cálculo dental (CD existentes na superfície dentária por meio de avaliação visual subjetiva. O presente estudo tem como objetivo avaliar o método de análise computadorizada para medição de área de PB e CD nos dentes de cães através da comparação com a avaliação visual. Foram utilizados 10 cães Beagles, três machos e sete fêmeas, com similares características e mantidos sob o mesmo manejo e dieta alimentar. As avaliações das superfícies vestibulares dos dentes ocorreram antes da profilaxia dentária, que foi realizada sob anestesia geral inalatória, e após sete dias para PB e após 28 dias para CD. A avaliação computadorizada da área de CD demonstrou ser estatisticamente melhor em relação à avaliação visual antes e após a profilaxia; entretanto, não demonstrou diferença significante na avaliação da PB. Concluiu-se que a avaliação computadorizada é vantajosa em relação à visual por conferir maior precisão na obtenção da proporção entre área total do dente e área acometida, mostrando-se estatistticamente superior na quantificação do CD após 28 dias.Periodontal disease is caused by dental plaque accumulation on teeth and adjacent structures. Indices have been formulated for its measurement considering the amount and intensity of dental plaque (DP and dental calculus (C on the surface of teeth through subjective visual evaluation. This study aims at assessing the computerized analysis method for measurement of DP and C areas on the teeth of dogs by comparing it with the visual evaluation in the oral cavity. Ten beagle dogs with similar characteristics and kept under the same management and diet were used. Evaluations of oral cavity occurred before surgical prophylaxis

  1. Modelo de web semántica para universidades

    Directory of Open Access Journals (Sweden)

    Karla Abad

    2015-12-01

    Full Text Available A raíz del estudio de estado actual de micrositios y repositorios en la Universidad Estatal Península de Santa Elena se encontró que su información carecía de semántica óptima y adecuada. Bajo estas circunstancias, se plantea entonces la necesidad de crear un modelo de estructura de web semántica para Universidades, el cual posteriormente fue aplicado a micrositios y repositorio digital de la UPSE, como caso de prueba. Parte de este proyecto incluye la instalación de módulos de software con sus respectivas configuraciones y la utilización de estándares de metadatos como DUBLIN CORE, para la mejora del SEO (optimización en motores de búsqueda; con ello se ha logrado la generación de metadatos estandarizados y la creación de políticas para la subida de información. El uso de metadatos transforma datos simples en estructuras bien organizadas que aportan información y conocimiento para generar resultados en buscadores web. Al culminar la implementación del modelo de web semántica es posible decir que la universidad ha mejorado su presencia y visibilidad en la web a través del indexamiento de información en diferentes motores de búsqueda y posicionamiento en la categorización de universidades y de repositorios de Webometrics (ranking que proporciona clasificación de universidades de todo el mundo.   Abstract After examining the current microsites and repositories situation in University, Peninsula of Santa Elena´s, it was found that information lacked optimal and appropriate semantic. Under these circumstances, there is a need to create a semantic web structure model for Universities, which was subsequently applied to UPSE´s microsites and digital repositories, as a test study case. Part of this project includes the installation of software modules with their respective configurations and the use of metadata standards such as DUBLIN CORE, to improve the SEO (Search Engine Optimization; with these applications, it was

  2. Multiple-Group Analysis Using the sem Package in the R System

    Science.gov (United States)

    Evermann, Joerg

    2010-01-01

    Multiple-group analysis in covariance-based structural equation modeling (SEM) is an important technique to ensure the invariance of latent construct measurements and the validity of theoretical models across different subpopulations. However, not all SEM software packages provide multiple-group analysis capabilities. The sem package for the R…

  3. Estudo de caso de oferta induzindo a demanda: o caso da oferta de exames de imagem (tomografia axial computadorizada e ressonância magnética na Unimed-Manaus Case study of supply induced demand: the case of provision of imaging scans (computed tomography and magnetic resonance at Unimed-Manaus

    Directory of Open Access Journals (Sweden)

    Edson de Oliveira Andrade

    2011-04-01

    Full Text Available OBJETIVO: Apresentar a experiência de uma operadora de plano de saúde (Unimed-Manaus na cidade de Manaus, Estado do Amazonas, com o credenciamento de serviços de imagem e a indução de demanda pela oferta dos novos serviços (Lei de Roemer. MÉTODOS: Trata-se de uma pesquisa de caráter retrospectivo, com estudo de série temporal, abordando o período de janeiro de 1998 a junho de 2004, lapso de tempo em que ocorreu a implantação dos serviços de tomografia computadorizada e da ressonância magnética no âmbito dos serviços oferecidos por aquele plano de saúde. A análise estatística consistiu em uma parte descritiva e uma inferencial, sendo esta última utilizando teste paramétrico de média (teste t de Student e ANOVA e o teste de correlação de Pearson. Foi adotado um alfa de 5% e um intervalo de confiança de 95%. RESULTADOS: Foi possível identificar na Unimed-Manaus que a oferta de novos serviços de imagem foi capaz de, por si só, gerar um aumento da demanda do serviço caracterizando o fenômeno descrito por Roemer. CONCLUSÃO: Os resultados deste trabalho ressaltam a necessidade de se estar atento ao fato de que a oferta de novos serviços no setor da saúde poderá acarretar, por si só, um aumento de sua utilização sem que haja uma demanda real.OBJECTIVE: To present the experience of a health plan operator (Unimed-Manaus in Manaus, Amazonas, Brazil, with the accreditation of imaging services and the demand induced by the supply of new services (Roemer's Law. METHODS: This is a retrospective work studying a time series covering the period from January 1998 to June 2004, in which the computed tomography and the magnetic resonance imaging services were implemented as part of the services offered by that health plan operator. Statistical analysis consisted of a descriptive and an inferential part, with the latter using a mean parametric test (Student T-test and ANOVA and the Pearson correlation test. A 5% alpha and a 95

  4. Opacidades em vidro fosco nas doenças pulmonares difusas: correlação da tomografia computadorizada de alta resolução com a anatomopatologia Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation

    Directory of Open Access Journals (Sweden)

    Maria Lúcia de Oliveira Santos

    2003-12-01

    Full Text Available Opacidade em vidro fosco é achado freqüentemente visto na tomografia computadorizada de alta resolução do tórax e se traduz pelo aumento do coeficiente de atenuação dos pulmões, mas sem apagar as marcas broncovasculares. Por sua inespecificidade, a associação com outros achados radiológicos, clínicos e anatomopatológicos deve ser considerada para uma interpretação diagnóstica mais correta. Neste trabalho foram analisados 62 exames tomográficos de pacientes com doenças pulmonares difusas, de 14 etiologias diferentes, em que opacidades em vidro fosco foram o achado único ou predominante, e feita correlação anatomopatológica por meio de biópsias ou necropsias. Na pneumocistose as opacidades em vidro fosco corresponderam, histologicamente, à ocupação alveolar por material espumoso contendo parasitos; no carcinoma bronquíolo-alveolar, a espessamento dos septos alveolares e ocupação de sua luz por muco e células tumorais; na paracoccidioidomicose, a espessamento dos septos alveolares, áreas de fibrose e alvéolos contendo exsudato broncopneumônico; na sarcoidose, a fibrose ou a acúmulo de granulomas; na fibrose pulmonar idiopática, a espessamento dos septos alveolares por fibrose; na bronquiolite obliterante com pneumonia em organização, a pneumonia intersticial com áreas de organização intra-alveolar. A ocupação alveolar por sangue foi observada nos casos de leptospirose, hemossiderose idiopática, metástases de tumor renal e na aspergilose invasiva; por vacúolos de gordura na pneumonia lipídica; por material protéico e lipoprotéico na silicoproteinose e na proteinose alveolar; e por líquido de edema na insuficiência cardíaca congestiva.Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its unspecificity

  5. Tomografia computadorizada de alta resolução na silicose: correlação com radiografia e testes de função pulmonar High-resolution computed tomography in silicosis: correlation with chest radiography and pulmonary function tests

    Directory of Open Access Journals (Sweden)

    Agnaldo José Lopes

    2008-05-01

    Full Text Available OBJETIVO: Correlacionar os parâmetros tomográficos com os de função pulmonar em portadores de silicose, bem como comparar os resultados da tomografia computadorizada de alta resolução (TCAR com os da radiografia de tórax. MÉTODOS: Foi realizado um estudo de corte transversal, em que foram avaliados 44 pacientes não-tabagistas e sem história pregressa de tuberculose. As radiografias foram classificadas de acordo com a proposta da Organização Internacional do Trabalho. Utilizando um sistema de escore semiquantitativo, os seguintes achados na TCAR foram quantificados: extensão total do envolvimento pulmonar, opacidades parenquimatosas e enfisema. Foram realizados espirometria, oscilações forçadas, avaliação dos volumes pulmonares pela técnica de diluição com hélio e medida da diffusing capacity of the lung for carbon monoxide (DLCO, capacidade de difusão do monóxido de carbono. RESULTADOS: Dos 44 pacientes estudados, 41 eram homens, com média de idade de 48,4 anos. Na análise comparativa, 4 pacientes classificados na categoria 0 pela radiografia foram reclassificados na categoria 1 pela TCAR e, enquanto a radiografia diagnosticou 23 casos de fibrose maciça progressiva, a TCAR estabeleceu esse diagnóstico em 33 doentes. Para o escore de opacidades, as maiores correlações foram observadas com as medidas de fluxo, DLCO e complacência. Já o enfisema correlacionou-se negativamente com as medidas de volume, DLCO e fluxo. Nesta amostra com predomínio de grandes opacidades (75% dos indivíduos, a deterioração da função pulmonar associou-se com a extensão das alterações estruturais. CONCLUSÕES: Na silicose, a TCAR é superior à radiografia tanto na detecção precoce da doença quanto na identificação de fibrose maciça progressiva.OBJECTIVE: To correlate tomographic findings with pulmonary function findings, as well as to compare chest X-ray findings with high resolution computed tomography (HRCT findings, in

  6. Análise do perfil facial masculino adulto jovem, esteticamente agradável, em fotografias padronizadas: comparação da medição manual com a computadorizada Facial profile analysis of esthetically harmonious young male adults in standardized photographs: comparison of manual versus computerized measurements

    Directory of Open Access Journals (Sweden)

    Isabella Cabral Alexandre Schlickmann

    2008-12-01

    Full Text Available OBJETIVO: analisar o perfil facial masculino adulto jovem, através de fotografias padronizadas e comparar a medição manual com a medição computadorizada por meio do software Cef X (CDT. MÉTODOS: a amostra consistiu de 40 indivíduos brasileiros brancos, com média de idade de 21,9 anos, que possuíam perfis agradáveis, oclusão normal, sem histórico de tratamento ortodôntico prévio. As fotografias coloridas de 10cm x 15cm foram obtidas de forma padronizada, com o indivíduo na posição natural da cabeça. As fotografias foram medidas manualmente, utilizando-se paquímetro digital e transferidor, e também através de computador, utilizando-se o programa Cef X (CDT. Trinta e seis variáveis faciais foram analisadas por meio de medidas lineares, angulares e proporcionais. RESULTADOS: as médias da medição manual e da medição por computador foram diferentes estatisticamente para 24 variáveis. No método por computador, somente uma medida mostrou diferença significativa entre a primeira e a segunda medição, enquanto na manual oito mostraram diferença. CONCLUSÕES: considerando-se que houve diferença entre as medições manual e por computador, deve-se utilizar as médias respectivas para cada tipo de medição. Os dois tipos de medição são confiáveis, entretanto a medição por computador é mais precisa. Devido à praticidade e agilidade da medição por computador, esta seria a mais indicada.Aim: To analyze the young male adult facial profile using standardized photographs and compare manual measuring procedures to the measuring procedures with the software Cef X (CDT. METHODS: The sample consisted of 40 Brazilian Caucasian individuals, with an average age of 21.9 years, who possessed pleasant profiles, normal occlusion, and no history of previous orthodontic treatment. Colored photographs measuring 10cm x 15cm were taken in a standard way with the subject in natural head position. The photographs were measured manually

  7. Análise perceptivo-auditiva, acústica computadorizada e laringológica da voz de adultos jovens fumantes e não-fumantes Auditory perceptual, acoustic, computerized and laryngological analysis of young smokers' and nonsmokers' voice

    Directory of Open Access Journals (Sweden)

    Daniele C. de Figueiredo

    2003-12-01

    Full Text Available OBJETIVO: Realizar a avaliação laringológica, análise perceptivo-auditiva e acústica computadorizada das vozes de adultos jovens fumantes e não-fumantes, sem queixa vocal, compará-las e verificar a incidência de alterações laríngeas. FORMA DE ESTUDO: Caso-controle. MATERIAL E MÉTODO: Foram analisadas as vozes de 80 indivíduos com idades compreendidas entre 20 e 40 anos. Estes foram divididos em quatro grupos: 20 homens fumantes, 20 homens não-fumantes, 20 mulheres fumantes e 20 mulheres não-fumantes. Este estudo envolveu laringoscopia, realizada e interpretada por uma médica otorrinolaringologista, e gravação em fita cassete das vogais sustentadas /a/, /m/, /i/ e /u/, contagem dos números de 1 a 20, emissão dos dias da semana, dos meses do ano e da canção "Parabéns a você". A gravação em fita cassete foi editada para posterior análise espectrográfica e avaliação perceptiva auditiva por quatro avaliadores com experiência na área de voz. RESULTADOS: Após a análise, foi constatada uma discreta diminuição da freqüência fundamental da voz dos indivíduos fumantes de ambos os sexos, bem como maior incidência de rouquidão e de alterações laríngeas entre os tabagistas.AIM: The goal of this study was to make the laryngological, auditory perceptual and acoustic computer analyses of young adults' (smokers and non-smokers voices, without vocal complaint, compare them and verify the incidence of vocal alterations. STUDY DESIGN: Clinical comparative. MATERIAL AND METHOD: The voices of 80 individuals with age range from 20 to 40 years were analyzed. These individuals were divided in four groups: 20 male smokers, 20 male non-smokers, 20 female smokers and 20 female non-smokers. This analysis involved laryngoscopy, which was performed and interpreted by an otolaryngologist, and cassette tape recordings of the sustained vowels /a/, /m/, /i/ e /u/, number counting from 1 to 20, speech of the days of the week, months of

  8. Sexual Arousal and Sexually Explicit Media (SEM: Comparing Patterns of Sexual Arousal to SEM and Sexual Self-Evaluations and Satisfaction Across Gender and Sexual Orientation

    Directory of Open Access Journals (Sweden)

    Gert Martin Hald, PhD

    2018-03-01

    Hald GM, Stulhofer A, Lange T, et al. Sexual Arousal and Sexually Explicit Media (SEM: Comparing Patterns of Sexual Arousal to SEM and Sexual Self-Evaluations and Satisfaction Across Gender and Sexual Orientation. Sex Med 2018;6:30–38.

  9. Quality control of clinker products by SEM and XRF analysis

    International Nuclear Information System (INIS)

    Ziad Abu Kaddourah; Khairun Azizi

    1996-01-01

    The microstructure and chemical properties of industrial Portland cement clinkers have been examined by SEM and XRF methods to establish the nature of the clinkers and how variations in the clinker characteristics can be used to control the clinker quality. The clinker nodules were found to show differences in the chemical composition and microstructure between the inner and outer parts of the clinker nodules. Microstructure studies of industrial Portland cement clinker have shown that the outer part of the nodules are enriched in silicate more than the inner part. There is better crystallization and larger alite crystal size in the outer part than in the inner part. The alite crystal size varied between 16.2 -46.12 μ m. The clinker chemical composition was found to affect the residual >45 μ m, where a higher belite content causes an increase in the residual >45 μ m in the the cement product and will cause a decrease in the concrete strength of the cement product. The aluminate and ferrite crystals and the microcracks within the alite crystal are clear in some clinker only. The quality of the raw material preparation, burning and cooling stages can be controlled using the microstructure of the clinker product

  10. Semáforo de habilidad digital para estudiantes universitarios

    Directory of Open Access Journals (Sweden)

    Javier Organista Sandoval

    2017-01-01

    Full Text Available El vertiginoso cambio tecnológico y el creciente uso de dispositivos portátiles en el entorno educativo universitario han propiciado una carga importante de mediación tecnológica del proceso educativo. Ante este contexto, el reto es lograr que los estudiantes aprovechen el potencial pedagógico que ofrecen estas herramientas. Para ello, el estudiante debe contar con las habilidades digitales para utilizar eficientemente las tecnologías digitales. Se parte de la identificación de las habilidades en torno al manejo de comunicación, información, organización y dispositivos con una orientación educativa. Los resultados mostraron que 68% de los estudiantes tienen un nivel aceptable de habilidad digital, 25% regular y un 7% insuficiente. El instrumento utilizado identifica las habilidades digitales que requieren mejorarse y se muestran mediante una señalización similar a la de un semáforo. En la medida en que se identifiquen las habilidades digitales que se requieran mejorar, se espera que la comunidad académica se apropie y aplique la tecnología digital en la educación, de cara a los desafíos de la formación de recursos humanos que la sociedad actual demanda.

  11. stainless steel by SEM-XRD and image analysis

    Directory of Open Access Journals (Sweden)

    Robinson Constanzo-R.

    2014-01-01

    Full Text Available El objetivo de este trabajo fue realizar un análisis cualitativ o de la distribución de un electrodepósito de cobre en el inter ior de electrodos porosos (EP de acero inoxidable y carbono grafito. Para ello, se reali zaron pruebas de electrodepositación de cobre a nivel de labora torio, con un posterior análisis de cortes de muestras de acero y grafito vía Microscopía Estereoscópica, Microscopía SEM-DRX y Análisis de Imagen, los cuales mostraron que el cobre no se deposita en forma uniforme al interior del electrodo. En el electrodo de acero, la penetra ción del depósito en el espesor fue alrededor de 50%, mientras que para el grafito a lrededor de 90%. En forma general, se observó un aumento de la cantidad de depósito hacia el extremo frente al ánodo y con sitios de difer ente crecimiento en depósito de cobre. Esto demuestra una distr ibución de corriente y potencial, función de parámetros físicos de electrodo y de la s características fisicoquímicas e hidrodinámicos del electroli to.

  12. SEM Based CARMA Time Series Modeling for Arbitrary N.

    Science.gov (United States)

    Oud, Johan H L; Voelkle, Manuel C; Driver, Charles C

    2018-01-01

    This article explains in detail the state space specification and estimation of first and higher-order autoregressive moving-average models in continuous time (CARMA) in an extended structural equation modeling (SEM) context for N = 1 as well as N > 1. To illustrate the approach, simulations will be presented in which a single panel model (T = 41 time points) is estimated for a sample of N = 1,000 individuals as well as for samples of N = 100 and N = 50 individuals, followed by estimating 100 separate models for each of the one-hundred N = 1 cases in the N = 100 sample. Furthermore, we will demonstrate how to test the difference between the full panel model and each N = 1 model by means of a subject-group-reproducibility test. Finally, the proposed analyses will be applied in an empirical example, in which the relationships between mood at work and mood at home are studied in a sample of N = 55 women. All analyses are carried out by ctsem, an R-package for continuous time modeling, interfacing to OpenMx.

  13. Automated SEM Modal Analysis Applied to the Diogenites

    Science.gov (United States)

    Bowman, L. E.; Spilde, M. N.; Papike, James J.

    1996-01-01

    Analysis of volume proportions of minerals, or modal analysis, is routinely accomplished by point counting on an optical microscope, but the process, particularly on brecciated samples such as the diogenite meteorites, is tedious and prone to error by misidentification of very small fragments, which may make up a significant volume of the sample. Precise volume percentage data can be gathered on a scanning electron microscope (SEM) utilizing digital imaging and an energy dispersive spectrometer (EDS). This form of automated phase analysis reduces error, and at the same time provides more information than could be gathered using simple point counting alone, such as particle morphology statistics and chemical analyses. We have previously studied major, minor, and trace-element chemistry of orthopyroxene from a suite of diogenites. This abstract describes the method applied to determine the modes on this same suite of meteorites and the results of that research. The modal abundances thus determined add additional information on the petrogenesis of the diogenites. In addition, low-abundance phases such as spinels were located for further analysis by this method.

  14. Simulation of FIB-SEM images for analysis of porous microstructures.

    Science.gov (United States)

    Prill, Torben; Schladitz, Katja

    2013-01-01

    Focused ion beam nanotomography-scanning electron microscopy tomography yields high-quality three-dimensional images of materials microstructures at the nanometer scale combining serial sectioning using a focused ion beam with SEM. However, FIB-SEM tomography of highly porous media leads to shine-through artifacts preventing automatic segmentation of the solid component. We simulate the SEM process in order to generate synthetic FIB-SEM image data for developing and validating segmentation methods. Monte-Carlo techniques yield accurate results, but are too slow for the simulation of FIB-SEM tomography requiring hundreds of SEM images for one dataset alone. Nevertheless, a quasi-analytic description of the specimen and various acceleration techniques, including a track compression algorithm and an acceleration for the simulation of secondary electrons, cut down the computing time by orders of magnitude, allowing for the first time to simulate FIB-SEM tomography. © Wiley Periodicals, Inc.

  15. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM

    International Nuclear Information System (INIS)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-01-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. - Highlights: • First practical application of epitaxial garnet films demonstrated in SEM. • Improved image quality of SEM equipped with GAGG:Ce single crystalline thin film scintillator. • Scintillation properties of GAGG:Ce films compared with standard bulk crystal scintillators.

  16. Prolongamentos na fala de adultos com e sem gagueira

    Directory of Open Access Journals (Sweden)

    Pâmila Bento da Silva

    Full Text Available RESUMO Objetivo: realizar uma análise quantitativa e qualitativa dos prolongamentos de adultos com e sem gagueira. Métodos: os participantes foram divididos em: Grupo de Pesquisa (GP, 15 adultos com gagueira e Grupo Controle (GC, 15 fluentes. Os procedimentos utilizados foram: avaliação da fluência, Instrumento de Gravidade da Gagueira e análises quantitativa e qualitativa dos prolongamentos. Resultados: GP mostrou maior número de prolongamentos não hesitativos, enquanto que GC mostrou maior ocorrência de prolongamentos hesitativos em relação ao total das disfluências. Prolongamentos não hesitativos ocorreram com maior frequência na palavra inicial e monossilábica, bem como na posição medial da frase para GP. Em relação à tensão muscular e duração, observou-se diferença apenas para a tensão muscular nos prolongamentos não hesitativos com maior média de ocorrência para GP. Conclusão: os prolongamentos não hesitativos ocorreram com maior frequência no GP, nas palavras iniciais, monossílabos e na posição medial da frase. Qualitativamente a tensão muscular foi uma característica típica dos prolongamentos não hesitativos no GP. Com relação aos prolongamentos hesitativos houve semelhança entre os adultos dos dois grupos quanto à frequência em relação ao total da fala, a posição dos prolongamentos nas palavras e nas frases e nos aspectos qualitativos, relacionados a tensão muscular e duração.

  17. Radiograma de tórax e tomografia computadorizada na avaliação do enfisema pulmonar Chest X-ray and computed tomography in the evaluation of pulmonary emphysema

    Directory of Open Access Journals (Sweden)

    Klaus Loureiro Irion

    2007-12-01

    Full Text Available O enfisema é uma condição do pulmão, caracterizada pelo aumento acima do normal no tamanho dos espaços aéreos distais ao bronquíolo terminal. Atualmente, o enfisema é a quarta causa de morte nos EUA, afetando 14 milhões de pessoas. O presente artigo descreve as principais ferramentas no diagnóstico por imagem do enfisema, desde o início até os dias de hoje. Relata as técnicas tradicionais, como radiograma de tórax, e as evoluções no campo da tomografia computadorizada (TC, como a TC de alta resolução e a densitovolumetria pulmonar por TC tridimensional.Emphysema is a condition of the lung, characterized by the abnormal increase in the size of the airspace distal to the terminal bronchioles. Currently, emphysema is the fourth leading cause of death in the USA, affecting 14 million people. The present article describes the principal tools in the imaging diagnosis of emphysema, from the early days until the present. We describe traditional techniques, such as chest X-ray, together with the evolution of computed tomography (CT to more advanced forms, such as high resolution CT, as well as three-dimensional CT densitometry and volumetric assessment.

  18. CD-SEM real time bias correction using reference metrology based modeling

    Science.gov (United States)

    Ukraintsev, V.; Banke, W.; Zagorodnev, G.; Archie, C.; Rana, N.; Pavlovsky, V.; Smirnov, V.; Briginas, I.; Katnani, A.; Vaid, A.

    2018-03-01

    Accuracy of patterning impacts yield, IC performance and technology time to market. Accuracy of patterning relies on optical proximity correction (OPC) models built using CD-SEM inputs and intra die critical dimension (CD) control based on CD-SEM. Sub-nanometer measurement uncertainty (MU) of CD-SEM is required for current technologies. Reported design and process related bias variation of CD-SEM is in the range of several nanometers. Reference metrology and numerical modeling are used to correct SEM. Both methods are slow to be used for real time bias correction. We report on real time CD-SEM bias correction using empirical models based on reference metrology (RM) data. Significant amount of currently untapped information (sidewall angle, corner rounding, etc.) is obtainable from SEM waveforms. Using additional RM information provided for specific technology (design rules, materials, processes) CD extraction algorithms can be pre-built and then used in real time for accurate CD extraction from regular CD-SEM images. The art and challenge of SEM modeling is in finding robust correlation between SEM waveform features and bias of CD-SEM as well as in minimizing RM inputs needed to create accurate (within the design and process space) model. The new approach was applied to improve CD-SEM accuracy of 45 nm GATE and 32 nm MET1 OPC 1D models. In both cases MU of the state of the art CD-SEM has been improved by 3x and reduced to a nanometer level. Similar approach can be applied to 2D (end of line, contours, etc.) and 3D (sidewall angle, corner rounding, etc.) cases.

  19. Anatomic considerations for C2 pedicle screw placement: the use of computerized tomography measurements Consideraciones anatómicas de la cocalización de los tornillos pediculares en C2: uitlización de las medidas de la tomografia computadorizada Considerações anatômicas sobre a localização dos parafusos pediculares em C2: utilização das medidas da tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Adebukoa Onibokun

    2009-03-01

    Full Text Available OBJECTIVE: more detailed anatomical knowledge of the C2 pedicle is required to optimize and minimize the risk of screw placement. The aim of this study was to evaluate the linear and angular dimensions of the true C2 pedicle using axial CT. METHODS: ninety three patients (47 males, 46 females mean age 48 years who had cervical spinal CT imaging performed were evaluated for this study. Axial images of the C2 pedicle were selected and the following pedicle parameters were determined: pedicle width (PW, the mediolateral diameter of the pedicle isthmus, perpendicular to the pedicle axis and pedicle transverse angle (PTA, that is, the angle between the pedicle axis and the midline of the vertebral body. RESULTS: the overall mean pedicle width was 5.8 1.2mm. The mean pedicle width in males (6.01.3mm was greater than that in the female subjects (5.6 1.1mm. This difference was not found to be statistically significant (p=.6790. The overall mean pedicle transverse angle was 43.93.9 degrees. The mean PTA in males was 43.23.8 degrees, while that in females was 44.73.7 degrees. CONCLUSION: preoperative planning is absolutely mandatory, particularly in determining not only screw trajectory, but in analyzing individual patient anatomy and reception to a C2 pedicle screw.OBJETIVO: el conocimiento detallado de las características anatómicas del pedículo de C2 es necesario para minimizar los riesgos relacionados con la colocación de los tornillos. El objetivo del estudio fue evaluar las medidas lineares y angulares del eje axial verdadero del pedículo de C2 utilizando la tomografía computadorizada. MÉTODOS: fueron utilizadas tomografías computadorizadas axiales de 93 pacientes (47 del sexo masculino y 46 del sexo femenino con promedio de edad de 48 años. Las imágenes axiales del pedículo de C2 fueron seleccionadas para el estudio y los parámetros estudiados fueron: Ancho del pedículo (diámetro mediolateral del istmo del pedículo perpendicular al

  20. Epigallocatechin-3-gallate rapidly remodels PAP85-120, SEM1(45-107, and SEM2(49-107 seminal amyloid fibrils

    Directory of Open Access Journals (Sweden)

    Laura M. Castellano

    2015-09-01

    Full Text Available Semen harbors amyloid fibrils formed by proteolytic fragments of prostatic acid phosphatase (PAP248-286 and PAP85-120 and semenogelins (SEM1 and SEM2 that potently enhance HIV infectivity. Amyloid but not soluble forms of these peptides enhance HIV infection. Thus, agents that remodel these amyloid fibrils could prevent HIV transmission. Here, we confirm that the green tea polyphenol, epigallocatechin-3-gallate (EGCG, slowly remodels fibrils formed by PAP248-286 termed SEVI (semen derived enhancer of viral infection and also exerts a direct anti-viral effect. We elucidate for the first time that EGCG remodels PAP85-120, SEM1(45-107, and SEM2(49-107 fibrils more rapidly than SEVI fibrils. We establish EGCG as the first small molecule that can remodel all four classes of seminal amyloid. The combined anti-amyloid and anti-viral properties of EGCG could have utility in preventing HIV transmission.

  1. A Proposal on the Quantitative Homogeneity Analysis Method of SEM Images for Material Inspections

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Hyun; Kim, Jong Woo; Shin, Chang Ho [Hanyang University, Seoul (Korea, Republic of); Choi, Jung-Hoon; Cho, In-Hak; Park, Hwan Seo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A scanning electron microscope (SEM) is a method to inspect the surface microstructure of materials. The SEM uses electron beams for imaging high magnifications of material surfaces; therefore, various chemical analyses can be performed from the SEM images. Therefore, it is widely used for the material inspection, chemical characteristic analysis, and biological analysis. For the nuclear criticality analysis field, it is an important parameter to check the homogeneity of the compound material for using it in the nuclear system. In our previous study, the SEM was tried to use for the homogeneity analysis of the materials. In this study, a quantitative homogeneity analysis method of SEM images is proposed for the material inspections. The method is based on the stochastic analysis method with the information of the grayscales of the SEM images.

  2. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    Science.gov (United States)

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  3. A Proposal on the Quantitative Homogeneity Analysis Method of SEM Images for Material Inspections

    International Nuclear Information System (INIS)

    Kim, Song Hyun; Kim, Jong Woo; Shin, Chang Ho; Choi, Jung-Hoon; Cho, In-Hak; Park, Hwan Seo

    2015-01-01

    A scanning electron microscope (SEM) is a method to inspect the surface microstructure of materials. The SEM uses electron beams for imaging high magnifications of material surfaces; therefore, various chemical analyses can be performed from the SEM images. Therefore, it is widely used for the material inspection, chemical characteristic analysis, and biological analysis. For the nuclear criticality analysis field, it is an important parameter to check the homogeneity of the compound material for using it in the nuclear system. In our previous study, the SEM was tried to use for the homogeneity analysis of the materials. In this study, a quantitative homogeneity analysis method of SEM images is proposed for the material inspections. The method is based on the stochastic analysis method with the information of the grayscales of the SEM images

  4. Application of SEM and EDX in studying biomineralization in plant tissues.

    Science.gov (United States)

    He, Honghua; Kirilak, Yaowanuj

    2014-01-01

    This chapter describes protocols using formalin-acetic acid-alcohol (FAA) to fix plant tissues for studying biomineralization by means of scanning electron microscopy (SEM) and qualitative energy-dispersive X-ray microanalysis (EDX). Specimen preparation protocols for SEM and EDX mainly include fixation, dehydration, critical point drying (CPD), mounting, and coating. Gold-coated specimens are used for SEM imaging, while gold- and carbon-coated specimens are prepared for qualitative X-ray microanalyses separately to obtain complementary information on the elemental compositions of biominerals. During the specimen preparation procedure for SEM, some biominerals may be dislodged or scattered, making it difficult to determine their accurate locations, and light microscopy is used to complement SEM studies. Specimen preparation protocols for light microscopy generally include fixation, dehydration, infiltration and embedding with resin, microtome sectioning, and staining. In addition, microwave processing methods are adopted here to speed up the specimen preparation process for both SEM and light microscopy.

  5. Comparison of SEM and VPSEM imaging techniques with respect to Streptococcus mutans biofilm topography.

    Science.gov (United States)

    Weber, Kathryn; Delben, Juliana; Bromage, Timothy G; Duarte, Simone

    2014-01-01

    The study compared images of mature Streptococcus mutans biofilms captured at increasing magnification to determine which microscopy method is most acceptable for imaging the biofilm topography and the extracellular polymeric substance (EPS). In vitro S. mutans biofilms were imaged using (1) scanning electron microscopy (SEM), which requires a dehydration process; (2) SEM and ruthenium red (SEM-RR), which has been shown to support the EPS of biofilms during the SEM dehydration; and (3) variable pressure scanning electron microscopy (VPSEM), which does not require the intensive dehydration process of SEM. The dehydration process and high chamber vacuum of both SEM techniques devastated the biofilm EPS, removed supporting structures, and caused cracking on the biofilm surface. The VPSEM offered the most comprehensive representation of the S. mutans biofilm morphology. VPSEM provides similar contrast and focus as the SEM, but the procedure is far less time-consuming, and the use of hazardous chemicals associated with SEM dehydration protocol is avoided with the VPSEM. The inaccurate representations of the biofilm EPS in SEM experimentation is a possible source of inaccurate data and impediments in the study of S. mutans biofilms. © 2013 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  6. Achados tomográficos das alterações abdominais pós-operatórias dos pacientes submetidos ao derivação gastrojejunal em Y-de-Roux sem anel

    Directory of Open Access Journals (Sweden)

    Fernanda Marcondes Ribas

    Full Text Available OBJETIVO: Avaliar por exame de tomografia computadorizada de pacientes submetidos à derivação gastrojejunal em Y-de-Roux, sem anel, para tratamento de obesidade mórbida. MÉTODOS: Estudaram-se 40 pacientes, encaminhados ao serviço de tomografia do Hospital Universitário Evangélico de Curitiba para avaliação diagnóstica. Encontravam-se em pós-operatório de cirurgia bariátrica tendo sido operados no mesmo hospital. Foram incluídos pacientes submetidos à operação laparoscópica com sintomas que necessitavam de avaliação tomográfica diagnóstica. Excluíram-se pacientes que tinham sido submetidos à cirurgia bariátrica por outras técnicas cirúrgicas; que tinham sido operados por outra equipe; que não concordassem com a administração de contraste iodado por via oral ou endovenosa; e que excediam o limite de peso da mesa de exame. Para análise estatística utilizou-se a média das variáveis. RESULTADOS: Os pacientes apresentaram-se com idade entre 23 a 70 anos e eram 11 homens e 29 mulheres. Não houve alterações extra-abdominais detectáveis pela tomografia de abdômen total; dos 40 pacientes avaliados, 30 apresentavam achados tomográficos dentro do limite da normalidade. A presença de estenose na anastomose gastrojejunal foi encontrada em um paciente; hérnia interna ocorreu em cinco; fístula anastomótica em um e abcesso em três dos pacientes estudados. CONCLUSÃO: A tomografia de abdome total não conseguiu informar a causa dos sintomas dos pacientes operados em 87,5% dos pacientes que procuraram re-avaliação médica por sintomas pós-operatórios da cirurgia bariátrica.

  7. Rinometria acústica, rinomanometria computadorizada e espirometria de doentes asmáticos com sintomas de rinite pré e pós-curso de corticóide oral

    Directory of Open Access Journals (Sweden)

    Dorivaldo Duarte

    2005-01-01

    Full Text Available Resumo: Introdução: Asma e rinite frequentemente coexistem no mesmo paciente. Parece existir uma condição que afecta o tracto respiratório como um todo e que pode produzir sintomas na via aérea inferior e/ou superior.Objetivo: Estudar as alterações funcionais das vias aéreas inferiores e superiores em pacientes em crise de asma antes e pós-curso de corticóide oral.Métodos: No período de Julho de 2000 a Agosto de 2002, dezasseis pacientes (69% do sexo feminino em crise de asma com sintomas de rinite atendidos no pronto atendimento de pneumologia foram analisados por meio de um ensaio clínico observacional porquestionário de sintomas, exame físico, radiograma, espirometria, rinometria acústica e rinomanometria computadorizada.Resultados: Dezasseis pacientes apresentaram sintomas de comprometimento das vias aéreas superiores. Na espirometria, o VEF1, o VEF1 /CVF e o FEF25-75%, apresentaram diferenças estatísticas significativas. A rinometria acústica apresentou diferença estatística significativa na área variável transversal mínima 1 e 2 do lado esquerdo e volume total nasal, pós-intervenção medicamentosa.Conclusões: Nas avaliações funcionais de vias aéreas inferiores e superiores, foram observadas melhora do VEF1, VEF1 /CVF e FEF, medidos pela espirometria e do volume total nasal, analisado pela 25-75% rinometria acústica pós-intervenção de corticóide oral.Rev Port Pneumol 2005; XI (1: 35-46 Abstract: Introduction: Asthma and rhinitis frequently coexist in the same patient. It may exist a specific condition witch affects the general respiratory activity and also able to produce symptoms into upper and/ or lower airways.Purpose: To analyze the alteration and functional burst of upper and lower airways before and after oral corticoid.Methods: From July of 2000 to August of 2002, sixteen (69 % was female, acute asthmatics patients with

  8. Volumetria hepática computadorizada como método de avaliação e acompanhamento da regeneração hepática após hepatectomia parcial em suínos

    Directory of Open Access Journals (Sweden)

    Fábio Augusto de Carvalho

    Full Text Available OBJETIVO: O estudo analisou a volumetria hepática por tomografia axial computadorizada, através de um programa informatizado semi-automático de aquisição e processamento de imagens digitalizadas, como parâmetro de acompanhamento da regeneração hepática em suínos, após hepatectomia parcial. MÉTODO: Doze suínos fêmeas, da raça Landrace, jovens, foram distribuídos em 3 grupos, conforme tempo de observação após o procedimento cirúrgico: 5(G5, 10(10 ou 15(G15 dias. Todos foram submetidos à hepatectomia parcial e, posteriormente, após acompanhamento, sacrificados, procedendo-se a retirada do fígado regenerado. A peça da hepatectomia e o fígado regenerado foram pesados e submetidos à realização da tomografia e aferição do volume através do software HEPATO®. Para análise estatística foram utilizados os testes não-paramétricos de Kruskal-Wallis e Wilcoxon. Valores de p<0,05 indicaram significância estatística. RESULTADOS: O peso do fígado regenerado foi de: G5=434,5g, G10=449,25g e G15=486,5 g, p=0,592. A regeneração hepática a partir do peso do fígado foi de 83,58% (G5, 94,95% (G10 e 101,63% (G15, p=0,197. O volume do fígado regenerado foi de 403,58 cm² (G5, 450,88 cm² (G10 e 458,93 cm² (G15, p=0,941. A regeneração hepática a partir do volume do fígado foi de 74,25% (G5, 88% (G10 e 100% (G15, p=0,326. Não houve diferença estatística significativa entre os parâmetros. CONCLUSÃO: A avaliação volumétrica por tomografia computadorizada, utilizando um programa informatizado semi-automático de aquisição e processamento de imagens digitalizadas, é método fidedigno para avaliação e acompanhamento da regeneração hepática em suínos, após hepatectomia parcial.

  9. Avaliação da concordância interobservadores na análise da polipose nasossinusal por meio da tomografia computadorizada Evaluation of the concordance between observers in sinunasal polyposis through computed tomographic analysis

    Directory of Open Access Journals (Sweden)

    Elaine A. Mendes

    2004-08-01

    Full Text Available Polipose nasossinusal (PNS é uma entidade de etiologia controversa, caracterizada por uma condição inflamatória da superfície mucosa das fossas nasais e seios paranasais, bilateralmente. A queixa principal do paciente consiste na obstrução nasal e, ao exame físico, observam-se freqüentemente massas polipóides ocupando as cavidades nasais em extensões variáveis. Além da rinoscopia anterior e da endoscopia nasal, o uso da tomografia computadorizada (TC torna-se necessário para avaliação das fossas nasais e da presença ou não do acometimento dos seios paranasais por essas massas, bem como a sua extensão. Este trabalho tem como objetivo avaliar a concordância interobservadores, por meio da análise da tomografia computadorizada, de 32 casos de PNS. FORMA DE ESTUDO: Clínico prospectivo. CASUÍSTICA E MÉTODOS: Foram avaliadas 32 TC de pacientes portadores PNS por dois observadores experientes, separadamente, em relação à presença ou não de 3 sinais tomográficos sugestivos dessa doença: (1 alargamento infundibular do complexo ostiomeatal, (2 abaulamento lateral da lâmina papirácea e (3 apagamento do trabeculado ósseo etmoidal. RESULTADOS: Observou-se Qui-quadrado não significante para o primeiro e segundo sinais (p=0,7055 e p=0,2057 e significante para o terceiro (p=0,0040. Contudo, o coeficiente de correlação de Kendall entre os dois observadores foi significante para os três sinais tomográficos acima citados (pSinonasal polyposis (SNP is a condition with a controversial aethiology, known by bilaterally inflammatory mucous membranes of nasal and paranasal sinuses. The major patient's complaint is nasal obstruction, and polypoid masses in different sizes can be found during nasal cavity examination. Beyond anterior rhinoscophy and nasal endoscopy, screening sinus computed tomography (SSCT is necessary to measure the size and the extent of the polyps into nasal cavities and paranasal sinuses. The purpose of this

  10. QEM*SEM: a necessary tool in the metallurgical evaluation of ore bodies

    International Nuclear Information System (INIS)

    Creelman, R.A.; Gottlieb, P.; Sutherland, D.; Jackson, R.

    1989-01-01

    The QEM*SEM system for automated image analysis of mineral samples is described. Details of the equipment are given together with information on the methods of measurement. Finally some practical applications are described where QEM*SEM has been used for the solution of metallurgical problems. 14 refs., 1 fig

  11. Strategic Enrolment Management (SEM) in Self-Financed Higher Education of Hong Kong: Evaluation and Measurement

    Science.gov (United States)

    Ng, Peggy; Galbraith, Craig

    2016-01-01

    The purpose of this study is to examine how the dimensions of strategic enrolment management (SEM) tie to the success metrics in the area of enrolment, retention and graduation from senior and programme management perspectives of a self-financed institution in Hong Kong. The literature on SEM has demonstrated that managing enrolment is a global…

  12. Shocked quartz in the SEM: Distinction between amorphous and healed PDFs

    NARCIS (Netherlands)

    Hamers, M.F.; Pennock, G.M.; Drury, M.R.

    2012-01-01

    Combined SEM techniques show that different CL signatures of PDFs are related to fresh and healed microstructures of PDFs and host quartz. This is confirmed by TEM results. A combination of SEM techniques can give the same type of information as TEM

  13. In-Situ tensile testing of propellants in SEM: influence of temperature

    NARCIS (Netherlands)

    Di Benedetto, G.L.; Ramshorst, M.C.J.; Duvalois, W.; Hooijmeijer, P.; Heijden, A. van der

    2017-01-01

    A tensile module system placed within a Scanning Electron Microscope (SEM) was utilized to conduct insitu tensile testing of propellant samples. The tensile module system allows for real-time in-situ SEM analysis of the samples to determine the failure mechanism of the propellant material under

  14. Detection of beetle damage in forests by X-ray CT image processing Detecção de danos causados por besouro em florestas com processamento de imagens de tomografia computadorizada de raios X

    Directory of Open Access Journals (Sweden)

    Paulo Estevão Cruvinel

    2003-10-01

    Full Text Available Some beetle species can have devastating economic impacts on forest and nursery industries. A recent example is Anophophora glabripennis, a species of beetle known in the United States as the ''Asian Longhorrned beetle'', which has damaged many American forests, and is a threat which can unintentionally reach south American countries, including Brazil. This work presents a new method based on X-ray computerized tomography (CT and image processing for beetle injury detection in forests. Its results show a set of images with correct identification of the location of beetles in living trees as well as damage evaluation with time.Algumas espécies de besouros têm elevado impacto econômico em florestas e indústrias de móveis. Exemplo recente é aquele produzido pelo besouro Anophophora glabripennis, uma espécie conhecida nos Estados Unidos como Asian Longhorn, que tem produzido danos significativos em várias florestas americanas, representando uma ameaça que poderá encontrar transporte não-intencional para países da América do Sul, inclusive para o Brasil. Neste trabalho é apresentado um novo método com base no uso de tomografia de raios X computadorizada (CT e processamento de imagens digitais para detecção de injúrias causadas por besouros em florestas. Os resultados mostram a correta identificação da localização de besouros em árvores vivas, como também fornecem uma avaliação do estrago temporal causado.

  15. Microlitíase alveolar pulmonar: achados na tomografia computadorizada de alta resolução do tórax em 10 pacientes Pulmonary alveolar microlithiasis: high-resolution computed tomography findings in 10 patients

    Directory of Open Access Journals (Sweden)

    Edson Marchiori

    2007-10-01

    Full Text Available OBJETIVO: Apresentar os achados na tomografia computadorizada de alta resolução (TCAR do tórax da microlitíase alveolar pulmonar. MÉTODOS: Foram estudadas, retrospectivamente, as tomografias de dez pacientes adultos, sete mulheres e três homens, com idade média de 38,7 anos. Os exames foram analisados por dois radiologistas, de forma independente, e as decisões finais foram obtidas por consenso. RESULTADOS: Os achados mais freqüentes foram as opacidades em vidro fosco e as calcificações subpleurais, ambas presentes em 90% dos pacientes estudados. Os outros achados de maior relevância foram pequenos nódulos parenquimatosos, calcificação ao longo dos septos interlobulares, cissuras nodulares, nódulos subpleurais, cistos subpleurais, consolidações densas e padrão de pavimentação em mosaico. CONCLUSÕES: A microlitíase alveolar pulmonar apresenta aspectos na TCAR que são altamente sugestivos da doença, na maior parte dos casos dispensando a realização de biópsias pulmonares.OBJECTIVE: To present the high-resolution computed tomography (HRCT findings of pulmonary alveolar microlithiasis. METHODS: The HRCT scans of 10 adult patients (seven females and three males; mean age, 38.7 years were retrospectively analyzed. The films were studied independently by two radiologists. RESULTS: The most common tomographic findings were ground-glass attenuation and linear subpleural calcifications, which were seen in 90% of the patients. Other relevant findings were small parenchymal nodules, calcification along the interlobular septa, nodular cissures, subpleural nodules, subpleural cysts, dense consolidations, and a mosaic pattern of attenuation. CONCLUSIONS: The HRCT findings presented by individuals with pulmonary alveolar microlithiasis are distinct. In most cases, such findings can form the basis of the diagnosis, eliminating the need to perform a lung biopsy.

  16. Quantitative roughness characterization and 3D reconstruction of electrode surface using cyclic voltammetry and SEM image

    Energy Technology Data Exchange (ETDEWEB)

    Dhillon, Shweta; Kant, Rama, E-mail: rkant@chemistry.du.ac.in

    2013-10-01

    Area measurements from cyclic voltammetry (CV) and image from scanning electron microscopy (SEM) are used to characterize electrode statistical morphology, 3D surface reconstruction and its electroactivity. SEM images of single phased materials correspond to two-dimensional (2D) projections of 3D structures, leading to an incomplete characterization. Lack of third dimension information in SEM image is circumvented using equivalence between denoised SEM image and CV area measurements. This CV-SEM method can be used to estimate power spectral density (PSD), width, gradient, finite fractal nature of roughness and local morphology of the electrode. We show that the surface morphological statistical property like distribution function of gradient can be related to local electro-activity. Electrode surface gradient micrographs generated here can provide map of electro-activity sites. Finally, the densely and uniformly packed small gradient over the Pt-surface is the determining criterion for high intrinsic electrode activity.

  17. From patterns to causal understanding: Structural equation modeling (SEM) in soil ecology

    Science.gov (United States)

    Eisenhauer, Nico; Powell, Jeff R; Grace, James B.; Bowker, Matthew A.

    2015-01-01

    In this perspectives paper we highlight a heretofore underused statistical method in soil ecological research, structural equation modeling (SEM). SEM is commonly used in the general ecological literature to develop causal understanding from observational data, but has been more slowly adopted by soil ecologists. We provide some basic information on the many advantages and possibilities associated with using SEM and provide some examples of how SEM can be used by soil ecologists to shift focus from describing patterns to developing causal understanding and inspiring new types of experimental tests. SEM is a promising tool to aid the growth of soil ecology as a discipline, particularly by supporting research that is increasingly hypothesis-driven and interdisciplinary, thus shining light into the black box of interactions belowground.

  18. Two novel approaches to study arthropod anatomy by using dualbeam FIB/SEM.

    Science.gov (United States)

    Di Giulio, Andrea; Muzzi, Maurizio

    2018-03-01

    Transmission Electron Microscopy (TEM) has always been the conventional method to study arthropod ultrastructure, while the use of Scanning Electron Microscopy (SEM) was mainly devoted to the examination of the external cuticular structures by secondary electrons. The new generation field emission SEMs are capable to generate images at sub-cellular level, comparable to TEM images employing backscattered electrons. The potential of this kind of acquisition becomes very powerful in the dual beam FIB/SEM where the SEM column is combined with a Focused Ion Beam (FIB) column. FIB uses ions as a nano-scalpel to slice samples fixed and embedded in resin, replacing traditional ultramicrotomy. We here present two novel methods, which optimize the use of FIB/SEM for studying arthropod anatomy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Quantitative roughness characterization and 3D reconstruction of electrode surface using cyclic voltammetry and SEM image

    International Nuclear Information System (INIS)

    Dhillon, Shweta; Kant, Rama

    2013-01-01

    Area measurements from cyclic voltammetry (CV) and image from scanning electron microscopy (SEM) are used to characterize electrode statistical morphology, 3D surface reconstruction and its electroactivity. SEM images of single phased materials correspond to two-dimensional (2D) projections of 3D structures, leading to an incomplete characterization. Lack of third dimension information in SEM image is circumvented using equivalence between denoised SEM image and CV area measurements. This CV-SEM method can be used to estimate power spectral density (PSD), width, gradient, finite fractal nature of roughness and local morphology of the electrode. We show that the surface morphological statistical property like distribution function of gradient can be related to local electro-activity. Electrode surface gradient micrographs generated here can provide map of electro-activity sites. Finally, the densely and uniformly packed small gradient over the Pt-surface is the determining criterion for high intrinsic electrode activity.

  20. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM.

    Science.gov (United States)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-04-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Tillandsia stricta Sol (Bromeliaceae) leaves as monitors of airborne particulate matter-A comparative SEM methods evaluation: Unveiling an accurate and odd HP-SEM method.

    Science.gov (United States)

    de Oliveira, Martha Lima; de Melo, Edésio José Tenório; Miguens, Flávio Costa

    2016-09-01

    Airborne particulate matter (PM) has been included among the most important air pollutants by governmental environment agencies and academy researchers. The use of terrestrial plants for monitoring PM has been widely accepted, particularly when it is coupled with SEM/EDS. Herein, Tillandsia stricta leaves were used as monitors of PM, focusing on a comparative evaluation of Environmental SEM (ESEM) and High-Pressure SEM (HPSEM). In addition, specimens air-dried at formaldehyde atmosphere (AD/FA) were introduced as an SEM procedure. Hydrated specimen observation by ESEM was the best way to get information from T. stricta leaves. If any artifacts were introduced by AD/FA, they were indiscernible from those caused by CPD. Leaf anatomy was always well preserved. PM density was determined on adaxial and abaxial leaf epidermis for each of the SEM proceedings. When compared with ESEM, particle extraction varied from 0 to 20% in air-dried leaves while 23-78% of particles deposited on leaves surfaces were extracted by CPD procedures. ESEM was obviously the best choice over other methods but morphological artifacts increased in function of operation time while HPSEM operation time was without limit. AD/FA avoided the shrinkage observed in the air-dried leaves and particle extraction was low when compared with CPD. Structural and particle density results suggest AD/FA as an important methodological approach to air pollution biomonitoring that can be widely used in all electron microscopy labs. Otherwise, previous PM assessments using terrestrial plants as biomonitors and performed by conventional SEM could have underestimated airborne particulate matter concentration. © 2016 Wiley Periodicals, Inc.

  2. Characterisation of nanoparticles by means of high-resolution SEM/EDS in transmission mode

    International Nuclear Information System (INIS)

    Hodoroaba, V-D; Rades, S; Mielke, J; Ortel, E; Salge, T; Schmidt, R

    2016-01-01

    Advances in scanning electron microscopy (SEM) enable the high-resolution imaging of single nanoparticles (NPs) with sizes well below 10 nm. The SEM analysis in transmission mode (T-SEM) of NPs on thin film supports has many benefits when compared to the analysis of NPs on bulk substrates. The enhanced material (mass - thickness) contrast of the T-SEM imaging mode is well suited for in-depth and, particularly valuable, to very accurate, traceable, lateral dimensional measurements of NPs. Compared to samples prepared on bulk substrates, T-SEM with energy dispersive X-ray spectroscopy (EDS) achieves a drastically improved spatial resolution of the emitted X-rays. The poor signal-to-noise ratio of the X-ray spectra emitted by a single nanoparticle (NP) can be improved by the use of high-sensitivity (high collection solid angle) silicon drift (SDD), energy-dispersive X-ray spectrometers (EDS). The EDS spectral imaging of a single NP with a spatial resolution below 10 nm has become possible. This is demonstrated by means of various examples of nanostructures. Advanced data processing of T-SEM/EDS results sets the stage for the automated classification of NPs by feature analysis. This method combines the detection of morphological structures of interest by image processing of T-SEM micrographs with the chemical classification by EDS. (paper)

  3. Inter-operator and inter-device agreement and reliability of the SEM Scanner.

    Science.gov (United States)

    Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L

    2015-02-01

    The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.

  4. A brief discussion about image quality and SEM methods for quantitative fractography of polymer composites.

    Science.gov (United States)

    Hein, L R O; Campos, K A; Caltabiano, P C R O; Kostov, K G

    2013-01-01

    The methodology for fracture analysis of polymeric composites with scanning electron microscopes (SEM) is still under discussion. Many authors prefer to use sputter coating with a conductive material instead of applying low-voltage (LV) or variable-pressure (VP) methods, which preserves the original surfaces. The present work examines the effects of sputter coating with 25 nm of gold on the topography of carbon-epoxy composites fracture surfaces, using an atomic force microscope. Also, the influence of SEM imaging parameters on fractal measurements is evaluated for the VP-SEM and LV-SEM methods. It was observed that topographic measurements were not significantly affected by the gold coating at tested scale. Moreover, changes on SEM setup leads to nonlinear outcome on texture parameters, such as fractal dimension and entropy values. For VP-SEM or LV-SEM, fractal dimension and entropy values did not present any evident relation with image quality parameters, but the resolution must be optimized with imaging setup, accompanied by charge neutralization. © Wiley Periodicals, Inc.

  5. Three-Dimensional (3D) Nanometrology Based on Scanning Electron Microscope (SEM) Stereophotogrammetry.

    Science.gov (United States)

    Tondare, Vipin N; Villarrubia, John S; Vlada R, András E

    2017-10-01

    Three-dimensional (3D) reconstruction of a sample surface from scanning electron microscope (SEM) images taken at two perspectives has been known for decades. Nowadays, there exist several commercially available stereophotogrammetry software packages. For testing these software packages, in this study we used Monte Carlo simulated SEM images of virtual samples. A virtual sample is a model in a computer, and its true dimensions are known exactly, which is impossible for real SEM samples due to measurement uncertainty. The simulated SEM images can be used for algorithm testing, development, and validation. We tested two stereophotogrammetry software packages and compared their reconstructed 3D models with the known geometry of the virtual samples used to create the simulated SEM images. Both packages performed relatively well with simulated SEM images of a sample with a rough surface. However, in a sample containing nearly uniform and therefore low-contrast zones, the height reconstruction error was ≈46%. The present stereophotogrammetry software packages need further improvement before they can be used reliably with SEM images with uniform zones.

  6. Sobre la estructura semántica de las palabras autosemánticas

    Directory of Open Access Journals (Sweden)

    Morales Ascencio Bernardo

    1993-06-01

    Full Text Available

    A partir de los conceptos de semema o estructura semémica y de los conceptos tradicionales de afijos y los accidentes gramaticales se plantea una supuesta estructura semántica profunda de la palabra, análoga a la de la oración en el modelo de la gramática de casos. Con base en este supuesto se reinterpretan algunas funciones semánticas de los afijos (particularmente de los sufijos, entre otras, como formas de la expresión de la modalidad léxica; se plantea una correlación entre rasgos semánticos específicos y las relaciones semánticas de caso. Por último se deducen algunas consideraciones pertinentes y se demuestra un isomorfismo entre la estructura profunda de la oración y la supuesta estructura semántica profunda de las palabras auto  semánticas.

  7. Diversity of seM in Streptococcus equi subsp. equi isolated from strangles outbreaks.

    Science.gov (United States)

    Libardoni, Felipe; Vielmo, Andréia; Farias, Luana; Matter, Letícia Beatriz; Pötter, Luciana; Spilki, Fernando Rosado; de Vargas, Agueda Castagna

    2013-03-23

    Strangles is the main upper respiratory tract disease of horses. There are currently no studies on the changes in alleles of the M protein gene (seM) in Brazilian isolates of Streptococcus equi ssp. equi (S. equi). This study aimed to analyze and differentiate molecularly S. equi isolates from equine clinical specimens from southern Brazil, between 1994 and 2010. seM alleles were analyzed in 47 isolates of S. equi obtained from clinical cases of strangles (15 Thoroughbred horses, 29 Crioulo breed horses and three Brasileiro de Hipismo--BH). seM alleles characterization was performed by comparing variable region sequences of the seM gene. The alleles were also phylogenetically grouped by Neighbor-joining analysis, which demonstrated the geographic distribution of those in properties from southern Brazil. Fifteen alleles of the gene seM were found among the 47 S. equi isolates analyzed. Among these, only one allele (seM-61), which was identified in seven isolates (14.9%), was found in the database PubMLST-seM. Within the new alleles, allele seM-115 was the most prevalent, having been found in 13 isolates (27.7%), followed by allele seM-117 in 10 isolates (21.3%). In the Brazilian horse population studied, there is greater diversity of M protein alleles in S. equi isolates compared to worldwide data deposited in PubMLST-seM. Among the 15 seM alleles identified, only one allele sequence was previously published. The alleles identification is important to control the disease by guiding selection of strains for the manufacture of commercial and autogenous vaccines. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Development of Focused Ion Beam technique for high speed steel 3D-SEM artefact fabrication

    DEFF Research Database (Denmark)

    Carli, Lorenzo; MacDonald, A. Nicole; De Chiffre, Leonardo

    2009-01-01

    The work describes preliminary manufacture by grinding, followed by machining on a Focused Ion Beam (FIB), of a high speed steel step artefact for 3D-SEM calibration. The FIB is coupled with a SEM in the so called dual beam instrument. The milling capabilities of FIB were checked from a qualitative...... point of view, using the dual beam SEM imaging, and quantitatively using a reference stylus instrument, to establish traceability. A triangular section having a depth of about 10 μm was machined, where the 50 μm curvature radius due to grinding was reduced to about 2 μm by FIB milling...

  9. The SEM description of interaction of a transient electromagnetic wave with an object

    Science.gov (United States)

    Pearson, L. W.; Wilton, D. R.

    1980-01-01

    The singularity expansion method (SEM), proposed as a means for determining and representing the transient surface current density induced on a scatterer by a transient electromagnetic wave is described. The resulting mathematical description of the transient surface current on the object is discussed. The data required to represent the electromagnetic scattering properties of a given object are examined. Experimental methods which were developed for the determination of the SEM description are discussed. The feasibility of characterizing the surface current induced on aircraft flying in proximity to a lightning stroke by way of SEM is examined.

  10. In-line CD metrology with combined use of scatterometry and CD-SEM

    Science.gov (United States)

    Asano, Masafumi; Ikeda, Takahiro; Koike, Toru; Abe, Hideaki

    2006-03-01

    Measurement characteristics in scatterometry and CD-SEM for lot acceptance sampling of inline critical dimension (CD) metrology were investigated by using a statistical approach with Monte Carlo simulation. By operation characteristics curve analysis, producer's risk and consumer's risk arising from sampling were clarified. Single use of scatterometry involves a higher risk, such risk being particularly acute in the case of large intra-chip CD variation because it is unable to sufficiently monitor intra-chip CD variation including local CD error. Substituting scatterometry for conventional SEM metrology is accompanied with risks, resulting in the increase of unnecessary cost. The combined use of scatterometry and SEM metrology in which the sampling plan for SEM is controlled by scatterometry is a promising metrology from the viewpoint of the suppression of risks and cost. This is due to the effect that CD errors existing in the distribution tails are efficiently caught.

  11. Mathematical model of the seismic electromagnetic signals (SEMS) in non crystalline substances

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, L. C. C.; Yahya, N.; Daud, H.; Shafie, A. [Electromagnetic cluster, Universiti Teknologi Petronas, 31750 Tronoh, Perak (Malaysia)

    2012-09-26

    The mathematical model of seismic electromagnetic waves in non crystalline substances is developed and the solutions are discussed to show the possibility of improving the electromagnetic waves especially the electric field. The shear stress of the medium in fourth order tensor gives the equation of motion. Analytic methods are selected for the solutions written in Hansen vector form. From the simulated SEMS, the frequency of seismic waves has significant effects to the SEMS propagating characteristics. EM waves transform into SEMS or energized seismic waves. Traveling distance increases once the frequency of the seismic waves increases from 100% to 1000%. SEMS with greater seismic frequency will give seismic alike waves but greater energy is embedded by EM waves and hence further distance the waves travel.

  12. SEM-668-G2(日东科技)

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    SEM-668-G2比SEM-668在视觉技术上更加精湛,采用美国AGILENT(安提伦)LASER 5519A及HP的双重频率技术,加强运动;隹确性。在智能化印刷头上,SEM-668-G2印刷质量更加均匀、稳定,操作界面更加简易、更加人性化。在综合性能上更加卓越,保证实现现代化的生产效率。产品体具性能如下:SEM-668-G2视觉全自动印刷机

  13. Mathematical model of the seismic electromagnetic signals (SEMS) in non crystalline substances

    International Nuclear Information System (INIS)

    Dennis, L. C. C.; Yahya, N.; Daud, H.; Shafie, A.

    2012-01-01

    The mathematical model of seismic electromagnetic waves in non crystalline substances is developed and the solutions are discussed to show the possibility of improving the electromagnetic waves especially the electric field. The shear stress of the medium in fourth order tensor gives the equation of motion. Analytic methods are selected for the solutions written in Hansen vector form. From the simulated SEMS, the frequency of seismic waves has significant effects to the SEMS propagating characteristics. EM waves transform into SEMS or energized seismic waves. Traveling distance increases once the frequency of the seismic waves increases from 100% to 1000%. SEMS with greater seismic frequency will give seismic alike waves but greater energy is embedded by EM waves and hence further distance the waves travel.

  14. Assessment of Paint Layers by FE-SEM and EDS Examination

    National Research Council Canada - National Science Library

    Harris, Donovan

    2004-01-01

    .... The approach was to remove free-film samples from each panel, fracture the films, and then examine at high magnification the cross sections using a field emission-scanning electron microscope (FE-SEM...

  15. Corrigendum to: Bayesian evaluation of informative hypotheses in SEM using Mplus

    NARCIS (Netherlands)

    van de Schoot, R.; Verhoeven, Marjolein; Hoijtink, H.

    2014-01-01

    This paper corrects: van de Schoot, R., Verhoeven, M., & Hoijtink, H. (2013). Bayesian evaluation ofinformative hypotheses in SEM using Mplus: A black bear story. EuropeanJournal of Developmental Psychology, 10, 81 –98.

  16. Automated CD-SEM recipe creation technology for mass production using CAD data

    Science.gov (United States)

    Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru

    2011-03-01

    Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).

  17. Understanding the Online : Jewellery Retail Market : an integrated model to conduct SEM

    OpenAIRE

    Wu, Yihong

    2013-01-01

    Research into e-commerce is becoming more and more popular; however the jewellery industry is somewhat special. There are very few studies having adapted a strategic marketing perspective on the online jewellery retail market. This study suggested an integrated online marketing strategy which focuses on the search engine marketing (SEM) approach. A detailed procedure of conducting search engine marketing (SEM) is introduced. Through the method of online questionnaires, with the help of soc...

  18. Why semicarbazide (SEM) is not an appropriate marker for the usage of nitrofurazone on agricultural animals.

    Science.gov (United States)

    Stadler, Richard H; Verzegnassi, Ludovica; Seefelder, Walburga; Racault, Lucie

    2015-01-01

    A comprehensive global database on semicarbazide (SEM) in foodstuffs and food ingredients is presented, with over 4000 data collected in foods such as seafood (crustaceans, fish powders), meat (beef, chicken powders), dairy products (e.g. raw milk, milk powders, whey, sweet buttermilk powder, caseinate, yoghurt, cheese), honey and other ingredients. The results provide evidence that the presence of SEM in certain dairy ingredients (whey, milk protein concentrates) is a by-product of chemical reactions taking place during the manufacturing process. Of the dairy ingredients tested (c. 2000 samples), 5.3% showed traces of SEM > 0.5 µg/kg. The highest incidence of SEM-positive samples in the dairy category were whey (powders, liquid) and milk protein concentrates (35% positive), with up to 13 µg/kg measured in a whey powder. Sweet buttermilk powder and caseinate followed, with 27% and 9.3% positives, respectively. SEM was not detected in raw milk, or in yoghurt or cheese. Of the crustacean products (shrimp and prawn powders) tested, 44% were positive for SEM, the highest value measured at 284 µg/kg. Fish powders revealed an unexpectedly high incidence of positive samples (25%); in this case, fraudulent addition of shellfish shells or carry-over during processing cannot be excluded. Overall, the data provide new insights into the occurrence of SEM (for dairy products and fish powders), substantially strengthening the arguments that SEM in certain food categories is not a conclusive marker of the use of the illegal antibiotic nitrofurazone.

  19. Information or resolution: Which is required from an SEM to study bulk inorganic materials?

    Science.gov (United States)

    Xing, Q

    2016-11-01

    Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. The electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energy-dispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. For an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly improve the usability of the SEM. SCANNING 38:864-879, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  20. The relationship between cost estimates reliability and BIM adoption: SEM analysis

    Science.gov (United States)

    Ismail, N. A. A.; Idris, N. H.; Ramli, H.; Rooshdi, R. R. Raja Muhammad; Sahamir, S. R.

    2018-02-01

    This paper presents the usage of Structural Equation Modelling (SEM) approach in analysing the effects of Building Information Modelling (BIM) technology adoption in improving the reliability of cost estimates. Based on the questionnaire survey results, SEM analysis using SPSS-AMOS application examined the relationships between BIM-improved information and cost estimates reliability factors, leading to BIM technology adoption. Six hypotheses were established prior to SEM analysis employing two types of SEM models, namely the Confirmatory Factor Analysis (CFA) model and full structural model. The SEM models were then validated through the assessment on their uni-dimensionality, validity, reliability, and fitness index, in line with the hypotheses tested. The final SEM model fit measures are: P-value=0.000, RMSEA=0.0790.90, TLI=0.956>0.90, NFI=0.935>0.90 and ChiSq/df=2.259; indicating that the overall index values achieved the required level of model fitness. The model supports all the hypotheses evaluated, confirming that all relationship exists amongst the constructs are positive and significant. Ultimately, the analysis verified that most of the respondents foresee better understanding of project input information through BIM visualization, its reliable database and coordinated data, in developing more reliable cost estimates. They also perceive to accelerate their cost estimating task through BIM adoption.

  1. Raman-in-SEM, a multimodal and multiscale analytical tool: performance for materials and expertise.

    Science.gov (United States)

    Wille, Guillaume; Bourrat, Xavier; Maubec, Nicolas; Lahfid, Abdeltif

    2014-12-01

    The availability of Raman spectroscopy in a powerful analytical scanning electron microscope (SEM) allows morphological, elemental, chemical, physical and electronic analysis without moving the sample between instruments. This paper documents the metrological performance of the SEMSCA commercial Raman interface operated in a low vacuum SEM. It provides multiscale and multimodal analyses as Raman/EDS, Raman/cathodoluminescence or Raman/STEM (STEM: scanning transmission electron microscopy) as well as Raman spectroscopy on nanomaterials. Since Raman spectroscopy in a SEM can be influenced by several SEM-related phenomena, this paper firstly presents a comparison of this new tool with a conventional micro-Raman spectrometer. Then, some possible artefacts are documented, which are due to the impact of electron beam-induced contamination or cathodoluminescence contribution to the Raman spectra, especially with geological samples. These effects are easily overcome by changing or adapting the Raman spectrometer and the SEM settings and methodology. The deletion of the adverse effect of cathodoluminescence is solved by using a SEM beam shutter during Raman acquisition. In contrast, this interface provides the ability to record the cathodoluminescence (CL) spectrum of a phase. In a second part, this study highlights the interest and efficiency of the coupling in characterizing micrometric phases at the same point. This multimodal approach is illustrated with various issues encountered in geosciences. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Feature evaluation of complex hysteresis smoothing and its practical applications to noisy SEM images.

    Science.gov (United States)

    Suzuki, Kazuhiko; Oho, Eisaku

    2013-01-01

    Quality of a scanning electron microscopy (SEM) image is strongly influenced by noise. This is a fundamental drawback of the SEM instrument. Complex hysteresis smoothing (CHS) has been previously developed for noise removal of SEM images. This noise removal is performed by monitoring and processing properly the amplitude of the SEM signal. As it stands now, CHS may not be so utilized, though it has several advantages for SEM. For example, the resolution of image processed by CHS is basically equal to that of the original image. In order to find wide application of the CHS method in microscopy, the feature of CHS, which has not been so clarified until now is evaluated correctly. As the application of the result obtained by the feature evaluation, cursor width (CW), which is the sole processing parameter of CHS, is determined more properly using standard deviation of noise Nσ. In addition, disadvantage that CHS cannot remove the noise with excessively large amplitude is improved by a certain postprocessing. CHS is successfully applicable to SEM images with various noise amplitudes. © Wiley Periodicals, Inc.

  3. Performance of SEM scintillation detector evaluated by modulation transfer function and detective quantum efficiency function.

    Science.gov (United States)

    Bok, Jan; Schauer, Petr

    2014-01-01

    In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e-beam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart-Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e-beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. © 2013 Wiley Periodicals, Inc.

  4. Biópsia percutânea de lesões ósseas guiada por tomografia computadorizada: taxas de definição diagnóstica e complicações

    Directory of Open Access Journals (Sweden)

    Macello Jose Sampaio Maciel

    2014-10-01

    Full Text Available Objetivo: Determinar taxas de definição diagnóstica e complicações da biópsia percutânea guiada por tomografia computadorizada (TC de lesões ósseas suspeitas de malignidade. Materiais e Métodos: Estudo retrospectivo que incluiu 186 casos de biópsia percutânea guiada por TC de lesões ósseas no período de janeiro de 2010 a dezembro de 2012. Todas as amostras foram obtidas usando agulhas de 8 a 10 gauge. Foram coletados dados demográficos, história de neoplasia maligna prévia, dados relacionados à lesão, ao procedimento e ao resultado histológico. Resultados: A maioria dos pacientes era do sexo feminino (57% e a idade média foi 53,0 ± 16,4 anos. Em 139 casos (74,6% a suspeita diagnóstica era metástase e os tumores primários mais comuns foram de mama (32,1% e próstata (11,8%. Os ossos mais envolvidos foram coluna vertebral (36,0%, bacia (32,8% e ossos longos (18,3%. Houve complicações em apenas três pacientes (1,6%, incluindo uma fratura, um caso de parestesia com comprometimento funcional e uma quebra da agulha necessitando remoção cirúrgica. Amostras de 183 lesões (98,4% foram consideradas adequadas para diagnóstico. Resultados malignos foram mais frequentes nos pacientes com suspeita de lesão secundária e história de neoplasia maligna conhecida (p < 0,001 e nos procedimentos orientados pela PET/CT (p = 0,011. Conclusão: A biópsia percutânea guiada por TC é segura e eficaz no diagnóstico de lesões ósseas suspeitas.

  5. Calcificação nos núcleos da base na tomografia computadorizada: correlação clínica em 25 pacientes consecutivos Basal ganglia calcification on computed tomography: clinical characteristics in 25 patients

    Directory of Open Access Journals (Sweden)

    Glória Maria A.S. Tedrus

    2006-03-01

    Full Text Available Analisamos os aspectos clínicos de 25 pacientes consecutivos que apresentaram calcificação nos núcleos da base na tomografia computadorizada (TC de crânio. Esta ocorreu em 0,68% de todos os exames realizados no período. Vinte e três pacientes apresentavam condições clínicas diversas, a saber: cefaléia em 7 casos, acidente vascular cerebral em 5, síndrome extrapiramidal em 2, processo expansivo cerebral em 2, epilepsia, retardo do desenvolvimento neuropsicomotor, demência e trauma de crânio em um caso cada ou outras condições neurológicas em 3. Não havia sintomas neurológicos em 2 casos. Em 15 pacientes (60,0% havia, além da calcificação dos núcleos da base, outras alterações na TC. Correlação clínica foi observada apenas com as outras alterações da TC e não com a calcificação dos núcleos da base, corroborando a hipótese de que esta possa ser um achado incidental.Twenty-five patients presenting basal ganglia calcification were assessed. This finding comprised 0.68% of all skull CT scan carried out during the period. Two patients were neurologically asymptomatic and 23 presented a variety neurological disorders - headache (7 patients, stroke (5 patients, extrapyramidal syndromes (2 patients, tumor (2 patients, epilepsy (1 patient, mental retardation (1 patient, dementia (1 patient, cranial trauma (1 patient, other neurological conditions (3 patients - or were asymptomatic from the neurological point of view (2 patients. Findings in the CT scan other than the basal ganglia calcification were observed in 15 (60% patients. There was a clinical-CT scan correlation in these cases but not in those in which the basal ganglia calcification was an isolated finding. This study highlights the fact that basal ganglia calcification is often a nonspecific finding on CT scan and that it may not be possible to establish a clinical-pathological correlation between them.

  6. SEM Leadership

    Science.gov (United States)

    Pollock, Kevin

    2012-01-01

    Expectations of higher education leaders are high, varied, and numerous. Leaders are expected not only to be visionary, decisive, and articulate, but also to share information, purposes, commitments, and struggles. Effective leaders must know and understand their faculty and staff; insist on realism; set clear goals and priorities; follow through;…

  7. The Effectiveness of Self-Expandable Metallic Stent Insertion in Treating Right-Sided Colonic Obstruction: A Comparison between SEMS and Decompression Tube Placement and an Investigation of the Safety and Difficulties of SEMS Insertion in Right Colons

    Directory of Open Access Journals (Sweden)

    Rintaro Moroi

    2014-01-01

    Full Text Available Objectives. Self-expandable metallic stent (SEMS is widely used to treat malignant colonic obstruction. However, most reports about SEMS insertion have concentrated on the left colon. This study aimed to (1 investigate the effectiveness of SEMS insertion compared with conventional decompression tube for right-sided colonic obstruction and (2 compare the safety and technical success of SEMS insertion between left- and right-sided colonic obstructions. Methods. The data from thirty-seven patients who underwent SEMS or conventional decompression tube placement for malignant colonic obstruction in our hospital were analyzed retrospectively. Technical and clinical success, complications, and technical difficulties were analyzed. We compared the results between SEMS insertion and decompression tube placement in right colons and the outcomes of SEMS insertion between right- and left-sided colonic obstructions. Results. For right colons, the clinical success rate of SEMS insertion (100% was significantly higher than that of decompression tube placement (55.9%. Concerning SEMS insertion, the technical difficulty and safety of SEMS insertion were similar between right- and left-sided colonic obstructions. Conclusion. SEMS insertion for right-sided colon is significantly more effective than conventional decompression tube placement, and this procedure was safer and less technically challenging than expected. SEMS insertion should be considered for treating right-sided malignant colonic obstruction.

  8. Recent improvement of a FIB-SEM serial-sectioning method for precise 3D image reconstruction - application of the orthogonally-arranged FIB-SEM.

    Science.gov (United States)

    Hara, Toru

    2014-11-01

    IntroductionWe installed the first "orthogonally-arranged" FIB-SEM in 2011. The most characteristic point of this instrument is that the FIB and SEM columns are perpendicularly mounted; this is specially designed to obtain a serial-sectioning dataset more accurately and precisely with higher contrast and higher spatial resolution compare to other current FIB-SEMs [1]. Since the installation in 2011, we have developed the hardware and methodology of the serial-sectioning based on this orthogonal FIB-SEM. In order to develop this technique, we have widely opened this instrument to every researcher of all fields. In the presentation, I would like to introduce some of application results that are obtained by users of this instrument. The characteristic points of the orthogonal systemFigure 1 shows a difference between the standard and the orthogonal FIB-SEM systems: In the standard system, shown in Fig.1(a), optical axes of a FIB and a SEM crosses around 60deg., while in the orthogonal system (Fig.1(b)), they are perpendicular to each other. The standard arrangement (a) is certainly suitable for TEM lamellae preparation etc. because the FIB and the SEM can see the same position simultaneously. However, for a serial-sectioning, it is not to say the best arrangement. One of the reasons is that the sliced plane by the FIB is not perpendicular to the electron beam so that the background contrast is not uniform and observed plane is distorted. On the other hand, in case of the orthogonally-arranged system,(b), these problems are resolved. In addition, spatial resolution can keep high enough even in a low accelerating voltage (e.g. 500V) because a working distance is set very small, 2mm. From these special design, we can obtain the serial-sectioning dataset from rather wide area (∼100um) with high spatial resolution (Max. 2×2×2nm). As this system has many kinds of detectors: SE, ET, Backscatter Electron(Energy-selective), EDS, EBSD, STEM(BF&ADF), with Ar+ ion-gun and a

  9. A combined SEM, CV and EIS study of multi-layered porous ceramic reactors for flue gas purification

    DEFF Research Database (Denmark)

    He, Zeming; Andersen, Kjeld Bøhm; Nygaard, Frederik Berg

    2013-01-01

    The effect of sintering temperature of 12-layered porous ceramic reactors (comprising 5 cells) was studied using scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The difference in microstructures of the reactors was evaluated by SEM...

  10. In-situ SEM microchip setup for electrochemical experiments with water based solutions

    International Nuclear Information System (INIS)

    Jensen, E.; Købler, C.; Jensen, P.S.; Mølhave, K.

    2013-01-01

    Studying electrochemical (EC) processes with electron microscopes offers the possibility of achieving much higher resolution imaging of nanoscale processes in real time than with optical microscopes. We have developed a vacuum sealed liquid sample electrochemical cell with electron transparent windows, microelectrodes and an electrochemical reference electrode. The system, called the EC-SEM Cell, is used to study electrochemical reactions in liquid with a standard scanning electron microscope (SEM). The central component is a microfabricated chip with a thin (50 nm) Si-rich silicon nitride (SiNx) window with lithographically defined platinum microelectrodes. We show here the design principles of the EC-SEM system, its detailed construction and how it has been used to perform a range of EC experiments, two of which are presented here. It is shown that the EC-SEM Cell can survive extended in-situ EC experiments. Before the EC experiments we characterized the beam current being deposited in the liquid as this will affect the experiments. The first EC experiment shows the influence of the electron-beam (e-beam) on a nickel solution by inducing electroless nickel deposition on the window when increasing the current density from the e-beam. The second experiment shows electrolysis in EC-SEM Cell, induced by the built-in electrodes. - Highlights: • New in-situ SEM system for electrochemistry. • In-situ Beam current measurements through liquid. • In-situ SEM E-beam-induced electroless deposition of Ni. • In-situ electrolysis

  11. In-situ SEM microchip setup for electrochemical experiments with water based solutions

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, E., E-mail: eric.jensen@nanotech.dtu.dk [DTU Nanotech, Technical University of Denmark, Ørsteds Plads, Building 345E, 2800 Kongens Lyngby (Denmark); DTU CEN, Technical University of Denmark, Fysikvej, Building 307, 2800 Kongens Lyngby (Denmark); Købler, C., E-mail: carsten.kobler@nanotech.dtu.dk [DTU Nanotech, Technical University of Denmark, Ørsteds Plads, Building 345E, 2800 Kongens Lyngby (Denmark); DTU CEN, Technical University of Denmark, Fysikvej, Building 307, 2800 Kongens Lyngby (Denmark); Jensen, P.S., E-mail: psj@kemi.dtu.dk [DTU Kemi, Technical University of Denmark, Kemitorvet, Building 207, 2800 Kongens Lyngby (Denmark); Mølhave, K., E-mail: kristian.molhave@nanotech.dtu.dk [DTU Nanotech, Technical University of Denmark, Ørsteds Plads, Building 345E, 2800 Kongens Lyngby (Denmark)

    2013-06-15

    Studying electrochemical (EC) processes with electron microscopes offers the possibility of achieving much higher resolution imaging of nanoscale processes in real time than with optical microscopes. We have developed a vacuum sealed liquid sample electrochemical cell with electron transparent windows, microelectrodes and an electrochemical reference electrode. The system, called the EC-SEM Cell, is used to study electrochemical reactions in liquid with a standard scanning electron microscope (SEM). The central component is a microfabricated chip with a thin (50 nm) Si-rich silicon nitride (SiNx) window with lithographically defined platinum microelectrodes. We show here the design principles of the EC-SEM system, its detailed construction and how it has been used to perform a range of EC experiments, two of which are presented here. It is shown that the EC-SEM Cell can survive extended in-situ EC experiments. Before the EC experiments we characterized the beam current being deposited in the liquid as this will affect the experiments. The first EC experiment shows the influence of the electron-beam (e-beam) on a nickel solution by inducing electroless nickel deposition on the window when increasing the current density from the e-beam. The second experiment shows electrolysis in EC-SEM Cell, induced by the built-in electrodes. - Highlights: • New in-situ SEM system for electrochemistry. • In-situ Beam current measurements through liquid. • In-situ SEM E-beam-induced electroless deposition of Ni. • In-situ electrolysis.

  12. The importance of scanning electron microscopy (sem in taxonomy and morphology of Chironomidae (Diptera

    Directory of Open Access Journals (Sweden)

    Andrzej Kownacki

    2015-07-01

    Full Text Available The paper reports on the value of scanning electron microscopy (SEM in the taxonomy and morphology of Chironomidae. This method has been relatively rarely used in Chironomidae studies. Our studies suggest that the SEM method provides a lot of new information. For example, the plastron plate of the thoracic horn of Macropelopia nebulosa (Meigen under light microscopy is visible as points, while under SEM we have found that it consists of a reticular structure with holes. By using SEM a more precise picture of the body structure of Chironomidae can be revealed. It allows researchers to explain inconsistencies in the existing descriptions of species. Another advantage of the SEM method is obtaining spatial images of the body and organs of Chironomidae. However, the SEM method also has some limitations. The main problem is dirt or debris (e.g. algae, mud, secretions, mucus, bacteria, etc., which often settles on the external surface of structures, especially those which are uneven or covered with hair. The dirt should be removed after collection of chironomid material because if left in place it can become chemically fixed to various surfaces. It unnecessarily remains at the surface and final microscopic images may contain artifacts that obscure chironomid structures being investigated. In this way many details of the surface are thus unreadable. The results reported here indicate that SEM examination helps us to identify new morphological features and details that will facilitate the identification of species of Chironomidae and may help to clarify the function of various parts of the body. Fast development of electron microscope technique allows us to learn more about structure of different organisms.

  13. Evaluation of depth of field in SEM images in terms of the information-passing capacity (IPC) and contrast gradient in SEM image

    International Nuclear Information System (INIS)

    Sato, Mitsugu; Ishitani, Tohru; Watanabe, Shunya; Nakagawa, Mine

    2004-01-01

    The depth of field (DoF) in scanning electron microscope (SEM) images has been determined by estimating the change of image sharpness or resolution near the exact focus position. The image sharpness or resolution along the optical axis is determined by calculating the information-passing capacity (IPC) of an optical system taking into account the effect of pixel size of the image. The change of image sharpness near the exact focus position is determined by measuring the slope gradient of the line profile in SEM images obtained at various focal positions of beam. The change of image sharpness along the optical axis determined by the IPC agrees well with those determined by the slope gradient of line profiles in SEM images when a Gaussian distribution having radius 0.86L p (L p : pixel size in image) at which the intensity has fallen to 1/e of the maximum is applied to the IPC calculation for each pixel intensity. The change of image sharpness near the exact focus position has also been compared with those determined by the CG (Contrast-to-Gradient) method. The CG method slightly underestimates the change of image sharpness compared with those determined by the IPC method

  14. Experimental investigation on 3D-SEM reconstructions of a wire gauge using stereo-pair technique

    DEFF Research Database (Denmark)

    Carli, Lorenzo; Genta, G.; Cantatore, Angela

    2011-01-01

    In this work an experimental investigation is addressed concerning 3D-SEM reconstructions obtained from the so-called stereo-pair technique. Three-dimensional topography of an object can be derived from two SEM images acquired from two different angles, through item rotation by means of the SEM...

  15. A Teoria dos Blocos Semânticos em revisão

    Directory of Open Access Journals (Sweden)

    Julio Cesar Machado

    2017-08-01

    Full Text Available A Teoria dos Blocos Semânticos ocupa lugar significativo nos trabalhos mundiais em Semântica, Argumentação e Enunciação, dentre outros. Por isso sua pertinência para a Linguística reclama uma reflexão. O presente trabalho pretende refletir algumas reformulações na Teoria dos Blocos Semânticos nas últimas duas décadas, a saber: (a polifonia, (b bloco semântico, e (c quadrado argumentativo. Especificamente, trataremos das seguintes relações: (a’ da Teoria Polifônica da Enunciação à Teoria Argumentativa da Polifonia; (b’ do bloco semântico ao semi-bloco; e (c’ do quadrado argumentativo ao cubo argumentativo. A necessidade deste trabalho é duplamente justificada: (i devido à constante revisão teórica do arcabouço teórico deste saber, sobretudo na sua última década, característica de Marion Carel e de Oswald Ducrot; e (ii pela falta de tradução/circulação no Brasil de obras fundamentais no que tange à re-elaboração das noções chaves desta teoria.

  16. SEM-REV: A sea test site for Marine Energy Converter

    International Nuclear Information System (INIS)

    Berhault, Christian; Le Crom, Izan; Le Bihan, Gerard

    2015-01-01

    Thanks to a main funding of Region des Pays de la Loire, the sea test site SEM-REV has been developed by Ecole Centrale de Nantes since 2007 to test both Wave Energy Converters and Floating Wind Turbine in real sea conditions. The sea test site is equipped with a set of oceanographic sensors and with an electric cable of 8 MW, connected to the French grid. The project is located close to Le Croisic, Western coast of France. SEM-REV is one of the main test facilities operated by Ecole Centrale de Nantes to support MRE technologies development. After presenting the initial motivations of the SEM-REV development, the paper describes, in parts 1 and 2, the complete administrative and technical processes that were followed to reach SEM-REV commissioning in 2014. The third part is focused on the exploitation process, including technical and contractual specifications imposed to the MRE developers for installation, tests and decommissioning phases. Some words are given also on the R and D projects using the SEM-REV in-situ monitoring system: prediction of environmental conditions, bio-fooling, acoustic impact. Even if operational phase is not started, expected extensions of the tests site are listed. (authors)

  17. The use of SEM/EDS method in mineralogical analysis of ordinary chondritic meteorite

    Directory of Open Access Journals (Sweden)

    Breda Mirtič

    2009-12-01

    Full Text Available The aim of this study was to evaluate the potential of scanning electron microscopy coupled with energy dispersiveX-ray spectroscopy (SEM/EDS for determination of mineral phases according to their stoichiometry and assessment of mineral composition of ordinary chondritic meteorite. For the purposes of this study, H3 type ordinary chondritic meteorite Abbott was selected. SEM/EDS allows identification and characterisation of mineralphases, whose size is below the resolution of an optical microscope. Mineral phases in chondrules and interstitial matrix were located in backscattered electron (BSE mode and were assessed from atomic proportions of constituent elements, obtained by the EDS analysis. SEM/EDS analyses of mineral phases showed that Abbott meteorite is characterised by Fe-rich (Fe, Ni-alloy kamacite, Fe-sulphide troilite or pyrrhotite, chromite, Mg-rich olivine, orthopyroxene bronzite or hypersthene, clinopyroxene Al-diopside, acid plagioclase oligoclase, accessory mineral chlorapatite and secondary minerals Fe-hydroxides (goethite or lepidocrocite. Results of semi-quantitative analyses confirmed that most of analysed mineralphases conform well to stoichiometric minerals with minor deviations of oxygen from stoichiometric proportions. Comparison between mineral phases in chondrules and interstitial matrix was also performed, however it showed no significant differences in elemental composition.Differences in chemical composition between minerals in interstitial matrix and chondrules are sometimes too small to be discernedby the SEM/EDS, therefore knowledge of SEM/EDS capabilities is important for correct interpretation of chondrite formation.

  18. In Situ Characterization of Boehmite Particles in Water Using Liquid SEM.

    Science.gov (United States)

    Yao, Juan; Arey, Bruce W; Yang, Li; Zhang, Fei; Komorek, Rachel; Chun, Jaehun; Yu, Xiao-Ying

    2017-09-27

    In situ imaging and elemental analysis of boehmite (AlOOH) particles in water is realized using the System for Analysis at the Liquid Vacuum Interface (SALVI) and Scanning Electron Microscopy (SEM). This paper describes the method and key steps in integrating the vacuum compatible SAVLI to SEM and obtaining secondary electron (SE) images of particles in liquid in high vacuum. Energy dispersive x-ray spectroscopy (EDX) is used to obtain elemental analysis of particles in liquid and control samples including deionized (DI) water only and an empty channel as well. Synthesized boehmite (AlOOH) particles suspended in liquid are used as a model in the liquid SEM illustration. The results demonstrate that the particles can be imaged in the SE mode with good resolution (i.e., 400 nm). The AlOOH EDX spectrum shows significant signal from the aluminum (Al) when compared with the DI water and the empty channel control. In situ liquid SEM is a powerful technique to study particles in liquid with many exciting applications. This procedure aims to provide technical know-how in order to conduct liquid SEM imaging and EDX analysis using SALVI and to reduce potential pitfalls when using this approach.

  19. New airtight transfer box for SEM experiments: Application to lithium and sodium metals observation and analyses.

    Science.gov (United States)

    Stephant, Nicolas; Grissa, Rabeb; Guillou, Fanch; Bretaudeau, Mickaël; Borjon-Piron, Yann; Guillet, Jacques; Moreau, Philippe

    2018-04-18

    The surface of some materials reacts very quickly on contact with air, either because it is oxidized or because it gets humidity from the air. For the sake of original surface observation by scanning electron microscopy (SEM), we conceived an airtight transfer box to keep the samples under vacuum from the place of manufacturing to the SEM chamber. This object is designed to fit in all the models of SEM including those provided with an airlock chamber. The design is voluntarily simplified to allow the manufacturing of the object by a standard mechanical workshop. The transfer box can be easily opened by gravity inside the SEM and allows the preservation of the best vacuum inside, before opening. SEM images and energy dispersive spectroscopy (EDX) analyses of metallic lithium and sodium samples are presented prior and after exposure to the air. X-ray Photoelectron Spectroscopy (XPS) analyses of all samples are also discussed in order to investigate the chemical environments of the detected elements. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Orientation mapping by transmission-SEM with an on-axis detector

    International Nuclear Information System (INIS)

    Fundenberger, J.J.; Bouzy, E.; Goran, D.; Guyon, J.; Yuan, H.; Morawiec, A.

    2016-01-01

    Conventional orientation mapping in a scanning electron microscope (SEM) is a valuable technique for characterizing crystalline materials, but its application to ultrafine or nano-grain materials is limited by its spatial resolution. The resolution can be increased by collecting transmission diffraction patterns in SEM. In previous works, such patterns were collected using off-axis detectors in nearly vertical position. To avoid some drawbacks of such arrangement, a new configuration was devised in which the scintillator is located underneath the thin foil on the optical axis of the microscope, and the light is reflected towards the camera by a mirror. This simple configuration gives intense patterns even at very low probe currents, and can be potentially used for collecting maps of relatively high spatial resolution. Example maps reveal details with dimensions of about 5 nm. Because of its resolution and geometric simplicity, the proposed configuration will open new opportunities in SEM-based characterization of nanocrystalline materials. - Highlights: • New experimental configuration for SEM-based orientation mapping is presented. • The geometry of recording transmission Kikuchi patterns in SEM is simplified. • The new configuration allows for reaching relatively high spatial resolution.

  1. Surgery on spinal epidural metastases (SEM) in renal cell carcinoma: a plea for a new paradigm.

    Science.gov (United States)

    Bakker, Nicolaas A; Coppes, Maarten H; Vergeer, Rob A; Kuijlen, Jos M A; Groen, Rob J M

    2014-09-01

    Prediction models for outcome of decompressive surgical resection of spinal epidural metastases (SEM) have in common that they have been developed for all types of SEM, irrespective of the type of primary tumor. It is our experience in clinical practice, however, that these models often fail to accurately predict outcome in the individual patient. To investigate whether decision making could be optimized by applying tumor-specific prediction models. For the proof of concept, we analyzed patients with SEM from renal cell carcinoma that we have operated on. Retrospective chart analysis 2006 to 2012. Twenty-one consecutive patients with symptomatic SEM of renal cell carcinoma. Predictive factors for survival. Next to established predictive factors for survival, we analyzed the predictive value of the Motzer criteria in these patients. The Motzer criteria comprise a specific and validated risk model for survival in patients with renal cell carcinoma. After multivariable analysis, only Motzer intermediate (hazard ratio [HR] 17.4, 95% confidence interval [CI] 1.82-166, p=.01) and high risk (HR 39.3, 95% CI 3.10-499, p=.005) turned out to be significantly associated with survival in patients with renal cell carcinoma that we have operated on. In this study, we have demonstrated that decision making could have been optimized by implementing the Motzer criteria next to established prediction models. We, therefore, suggest that in future, in patients with SEM from renal cell carcinoma, the Motzer criteria are also taken into account. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Soft tissue digestion of Paradiplozoon vaalense for SEM of sclerites and simultaneous molecular analysis.

    Science.gov (United States)

    Dos Santos, Q M; Avenant-Oldewage, A

    2015-02-01

    Classification of most monogeneans is primarily based on size, shape, and arrangement of haptoral sclerites. These structures are often obscured or misinterpreted when studied using light microscopy, leading to confusion regarding defining characters. Scanning electron microscopy (SEM) has predominantly been used to study haptoral sclerites in smaller monogeneans, focusing on hooks and anchors. In the Diplozoidae, SEM has not been used to study haptoral sclerites. Using new and modified techniques, the sclerites of diplozoids collected in South Africa were successfully studied using SEM. The digestion buffer from a DNA extraction kit was used to digest the surrounding tissue, and Poly-L-lysine-coated and concavity slides were employed to limit the movement and loss of sclerites, with the latter being more user-friendly. In addition to the success of visualizing the sclerites using SEM, the digested tissue from as little as half of the haptor provided viable genetic material for molecular characterization. From the results presented here, the study of the sclerites of larger monogeneans using SEM, including those bearing clamps, is a viable possibility for future research. Also, this method may be beneficial for the study of other, non-haptoral sclerites, such as cirri in other families of monogeneans. During this study, Labeo capensis was noted as a valid host of Paradiplozoon vaalense in a region of the Vaal River where the type host, Labeo umbratus, appears to be absent.

  3. SEM/EDS and optical microscopy analyses of microplastics in ocean trawl and fish guts.

    Science.gov (United States)

    Wang, Zhong-Min; Wagner, Jeff; Ghosal, Sutapa; Bedi, Gagandeep; Wall, Stephen

    2017-12-15

    Microplastic particles from Atlantic and Pacific Ocean trawls, lab-fed fish guts and ocean fish guts have been characterized using optical microscopy and SEM/EDS in terms of size, morphology, and chemistry. We assessed whether these measurements could serve as a rapid screening process for subsequent identification of the likely microplastic candidates by micro-spectroscopy. Optical microscopy enabled morphological classification of the types of particles or fibers present in the sample, as well as the quantification of particle size ranges and fiber lengths. SEM/EDS analysis was used to rule out non-plastic particles and screen the prepared samples for potential microplastic, based on their element signatures and surface characteristics. Chlorinated plastics such as polyvinyl chloride (PVC) could be easily identified with SEM/EDS due to their unique elemental signatures including chlorine, as could mineral species that are falsely identified as plastics by optical microscopy. Particle morphology determined by optical microscopy and SEM suggests the fish ingested particles contained both degradation fragments from larger plastic pieces and also manufactured microplastics. SEM images of microplastic particle surfaces revealed characteristic cracks consistent with environmental exposure, as well as pigment particles consistent with manufactured materials. Most of the microplastic surfaces in the fish guts and ocean trawls were covered with biofilms, radiolarians, and crustaceans. Many of the fish stomachs contained micro-shell pieces which visually resembled microplastics. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Minimal resin embedding of multicellular specimens for targeted FIB-SEM imaging.

    Science.gov (United States)

    Schieber, Nicole L; Machado, Pedro; Markert, Sebastian M; Stigloher, Christian; Schwab, Yannick; Steyer, Anna M

    2017-01-01

    Correlative light and electron microscopy (CLEM) is a powerful tool to perform ultrastructural analysis of targeted tissues or cells. The large field of view of the light microscope (LM) enables quick and efficient surveys of the whole specimen. It is also compatible with live imaging, giving access to functional assays. CLEM protocols take advantage of the features to efficiently retrace the position of targeted sites when switching from one modality to the other. They more often rely on anatomical cues that are visible both by light and electron microscopy. We present here a simple workflow where multicellular specimens are embedded in minimal amounts of resin, exposing their surface topology that can be imaged by scanning electron microscopy (SEM). LM and SEM both benefit from a large field of view that can cover whole model organisms. As a result, targeting specific anatomic locations by focused ion beam-SEM (FIB-SEM) tomography becomes straightforward. We illustrate this application on three different model organisms, used in our laboratory: the zebrafish embryo Danio rerio, the marine worm Platynereis dumerilii, and the dauer larva of the nematode Caenorhabditis elegans. Here we focus on the experimental steps to reduce the amount of resin covering the samples and to image the specimens inside an FIB-SEM. We expect this approach to have widespread applications for volume electron microscopy on multiple model organisms. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Refinement of Monte Carlo simulations of electron-specimen interaction in low-voltage SEM

    International Nuclear Information System (INIS)

    Kieft, Erik; Bosch, Eric

    2008-01-01

    A Monte Carlo tool is presented for the simulation of secondary electron (SE) emission in a scanning electron microscope (SEM). The tool is based on the Geant4 platform of CERN. The modularity of this platform makes it comparatively easy to add and test individual physical models. Our aim has been to develop a flexible and generally applicable tool, while at the same time including a good description of low-energy (<50 eV) interactions of electrons with matter. To this end we have combined Mott cross-sections with phonon-scattering based cross-sections for the elastic scattering of electrons, and we have adopted a dielectric function theory approach for inelastic scattering and generation of SEs. A detailed model of the electromagnetic fields from an actual SEM column has been included in the tool for ray tracing of secondary and backscattered electrons. Our models have been validated against experimental results through comparison of the simulation results with experimental yields, SE spectra and SEM images. It is demonstrated that the resulting simulation package is capable of quantitatively predicting experimental SEM images and is an important tool in building a deeper understanding of SEM imaging.

  6. Prevalence of soft tissue calcifications in cone beam computed tomography images of the mandible = Prevalência de calcificações em tecido mole na região mandibular avaliadas por dois sistemas de tomografia computadorizada por feixe cônico

    OpenAIRE

    Nunes, Leiliane Ferreira da Silva

    2011-01-01

    Objetivo: Determinar a prevalência de calcificações em tecido mole na região mandibular por meio de análise de imagens axiais provenientes de dois sistemas de tomografia computadorizada por feixe cônico (TCFC), NewTom 3G® e Classic i-Cat® Método: Foram avaliadas 246 imagens da região mandibular. Destas, 163 foram adquiridas no aparelho NewTom 3G® e 83 no aparelho Classic i-Cat®. A análise estatística foi baseada no teste exato de Fisher e no teste Qui-quadrado para comparação das proporçõe...

  7. Análise das variações morfológicas da ATM em pacientes com artrite reumatóide através de tomografia computadorizada = Analysis of the morphologyc variations in the TMJ the patients with rheumatoid arthritis through the computer tomography

    Directory of Open Access Journals (Sweden)

    Vasconcelos, Belmiro Cavalcanti do Egito

    2005-01-01

    Full Text Available Realizou-se um estudo qualitativo e quantitativo enfocando as alterações morfométricas da articulação temporomandibular (ATM, em pacientes com o diagnóstico de artrite reumatóide (AR por meio de tomografia computadorizada. Foram analisados 6 casos onde são descritas as alterações estruturais dos componentes ósseos de 12 ATMs. Os resultados indicaram que todas as ATMs apresentaram alterações, sendo as alterações mais freqüentes a esclerose óssea subcondral, seguida do aplainamento da eminência articular. Todos os pacientes apresentaram distúrbio de mobilidade

  8. Speciation of uranium in minerals by Sem, Tem, μ-PIXE, XPS and XAFS

    International Nuclear Information System (INIS)

    Toshihiko Ohnuki; Hiroshi Isobe; Tomihiro Kamiya; Takuro Sakai; Takashi Murakami

    2001-01-01

    Many kinds of electromagnetic waves and particle beams are used as analytical probes for the investigation of uranium-mineralogy and speciation. The representatives of the probes are SEM, TEM, μ-PIRE, XPS and XAFS. Each of these analytical probes has its own advantages and disadvantages. We have performed studies to compare the advantages and disadvantages on the basis of the analysis of the distribution and speciation of U containing rock samples collected at the Koongarra uranium deposit, Australia. The spatial resolutions of the probes are in the order of TEM>SEM, μ-PIXE>XFAS, XPS. The lower detection limits of the probes are in the order of μ-PIXE< TEM, SEM< XFAS, XPS. Oxidation state of U was determined by XFAS and XPS. These results indicate that combination of the above probes can give us sufficient data on U speciation not only in natural rock samples but in solid samples obtained in the laboratory. (authors)

  9. Carotene location in processed food samples measured by cryo In-SEM Raman.

    Science.gov (United States)

    Lopez-Sanchez, Patricia; Schumm, Stephan; Pudney, Paul D A; Hazekamp, Johan

    2011-09-21

    Cryo In-SEM Raman has been used for the first time to localise carotene compounds in a food matrix. Raman spectra of lycopene and β-carotene have been obtained from sampling oil droplets and plant cell structures visualised with cryo-SEM in tomato and carrot based emulsions containing 5% oil. It was possible to identify the carotenoids in both the oil droplets and the cell walls. Furthermore our results gave some indication that the carotenoids were in the non-crystalline state. It has been suggested that a higher amount of carotenes solubilised into the oil phase of the food matrix would lead to a higher bioaccessibility, thus understanding the effect of processing conditions on micronutrients distribution in a food matrix might help the design of plant based food products with a better nutritional quality. This shows improved structural characterisation of the cryo-SEM with the molecular sensitivity of Raman spectroscopy as a promising approach for complex biological problems.

  10. The advancement of the built environment research through employment of structural equation modeling (SEM)

    Science.gov (United States)

    Wasilah, S.; Fahmyddin, T.

    2018-03-01

    The employment of structural equation modeling (SEM) in research has taken an increasing attention in among researchers in built environment. There is a gap to understand the attributes, application, and importance of this approach in data analysis in built environment study. This paper intends to provide fundamental comprehension of SEM method in data analysis, unveiling attributes, employment and significance and bestow cases to assess associations amongst variables and constructs. The study uses some main literature to grasp the essence of SEM regarding with built environment research. The better acknowledgment of this analytical tool may assist the researcher in the built environment to analyze data under complex research questions and to test multivariate models in a single study.

  11. High resolution SEM characterization of nano-precipitates in ODS steels.

    Science.gov (United States)

    Jóźwik, Iwona; Strojny-Nędza, Agata; Chmielewski, Marcin; Pietrzak, Katarzyna; Kurpaska, Łukasz; Nosewicz, Szymon

    2018-05-01

    The performance of the present-day scanning electron microscopy (SEM) extends far beyond delivering electronic images of the surface topography. Oxide dispersion strengthened (ODS) steel is on of the most promising materials for the future nuclear fusion reactor because of its good radiation resistance, and higher operation temperature up to 750°C. The microstructure of ODS should not exceed tens of nm, therefore there is a strong need in a fast and reliable technique for their characterization. In this work, the results of low-kV SEM characterization of nanoprecipitates formed in the ODS matrix are presented. Application of highly sensitive photo-diode BSE detector in SEM imaging allowed for the registration of single nm-sized precipitates in the vicinity of the ODS alloys. The composition of the precipitates has been confirmed by TEM-EDS. © 2018 Wiley Periodicals, Inc.

  12. Enhanced EDX images by fusion of multimodal SEM images using pansharpening techniques.

    Science.gov (United States)

    Franchi, G; Angulo, J; Moreaud, M; Sorbier, L

    2018-01-01

    The goal of this paper is to explore the potential interest of image fusion in the context of multimodal scanning electron microscope (SEM) imaging. In particular, we aim at merging the backscattered electron images that usually have a high spatial resolution but do not provide enough discriminative information to physically classify the nature of the sample, with energy-dispersive X-ray spectroscopy (EDX) images that have discriminative information but a lower spatial resolution. The produced images are named enhanced EDX. To achieve this goal, we have compared the results obtained with classical pansharpening techniques for image fusion with an original approach tailored for multimodal SEM fusion of information. Quantitative assessment is obtained by means of two SEM images and a simulated dataset produced by a software based on PENELOPE. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  13. Development of an Economical Interfacing Circuit for Upgrading of SEM Data Printing System

    International Nuclear Information System (INIS)

    Punnachaiya, S.; Thong-Aram, D.

    2002-01-01

    The operating conditions of a Scanning Electron Microscope (SEM) i.e., magnification, accelerating voltage, micron mark and film identification labeling, are very important for the accurate interpretation of a micrograph picture. In the old model SEM, the built-in data printing system for film identification can be inputted only the numerical number. This will be made a confusing problems when various operating conditions were applied in routine work. An economical interfacing circuit, therefore, was developed to upgrade the data printing system for capable of alphanumerical labeling. The developed circuit was tested on both data printing systems of JSM-T220 and JSM-T330 (JEOL SEM). It was found that the interfacing function worked properly and easily installed

  14. Comparison of multilayered nanowire imaging by SEM and Helium Ion Microscopy

    International Nuclear Information System (INIS)

    Inkson, B J; Peng, Y; Jepson, M A E; Rodenburg, C; Liu, X

    2010-01-01

    The helium ion microscope (HeIM) is capable of probe sizes smaller than SEM and, with intrinsically small ion/sample interaction volumes, may therefore potentially offer higher spatial resolution secondary electron (SE) imaging of nanostructures. Here 55 nm diameter CoPt/Pt multilayered nanowires have been imaged by HeIM, SEM and TEM. It is found that there is an increased resolution of nanowire surface topography in HeIM SE images compared to SEM, however there is a reduction of materials contrast of the alternating Pt and CoPt layers. This can be attributed to the increased contribution of surface contamination layers to the ion-induced SE signal, and carbon is also observed to grow on the nanowires under prolonged HeIM scanning.

  15. Precise and economic FIB/SEM for CLEM: with 2 nm voxels through mitosis.

    Science.gov (United States)

    Luckner, Manja; Wanner, Gerhard

    2018-05-23

    A portfolio is presented documenting economic, high-resolution correlative focused ion beam scanning electron microscopy (FIB/SEM) in routine, comprising: (i) the use of custom-labeled slides and coverslips, (ii) embedding of cells in thin, or ultra-thin resin layers for correlative light and electron microscopy (CLEM) and (iii) the claim to reach the highest resolution possible with FIB/SEM in xyz. Regions of interest (ROIs) defined in light microscope (LM), can be relocated quickly and precisely in SEM. As proof of principle, HeLa cells were investigated in 3D context at all stages of the cell cycle, documenting ultrastructural changes during mitosis: nuclear envelope breakdown and reassembly, Golgi degradation and reconstitution and the formation of the midzone and midbody.

  16. Encontros e desvios nos semáforos: investigando artistas em Florianópolis/SC

    Directory of Open Access Journals (Sweden)

    Beatriz S. Albino

    2013-03-01

    Full Text Available http://dx.doi.org/10.5007/2178-4582.2012v46n2p469 A ideia de investigar artistas que atuam em semáforos de Florianópolis/SC teve sua origem em um estranhamento que nos fez vê-los na forma de uma alteridade radical. A pesquisa etnográfica permitiu descobrir relações simbólicas de pertencimentoe de desvio entre os artistas, destacando-se a figura de um “outro”, próximo, mas perigoso, que partilha simbolicamente os semáforos: o micróbio, estrangeiro que faria confundir o artista com a marginalidade. No semáforo ocorre também, no entanto, a reafirmação, por meio das performances dos artistas, do que deles é esperado: a comicidade, o virtuosismo, a aparência adequada.

  17. PAT and SEM study of porous silicon formed by anodization methods

    International Nuclear Information System (INIS)

    Liu Jian; Wei Long; Wang Huiyao; Ma Chuangxin; Wang Baoyi

    2000-01-01

    The porous silicon formed by anodization of crystal silicon was studied by positron annihilation technique (PAT) and scanning electron microscopy (SEM). The PAT experiments showed that the mean life and vacancy defects increased with the increasing anodization time. While the intensities of the longest lifetime, several ns-tens ns (ortho-positronium) dropped down. Small single-crystal Si spheres with mean radius of a few μm were observed by SEM after anodization. Pits with mean radius of a few μm from the divorcement of single-crystal spheres were also observed after further anodization. The increases of vacancy defects might be that the extension of structures of porous silicon towards inner layer with anodization time and caused more vacancy defects in inner layer. The SEM observation presented another possibility of the increase of density of vacancy defects in surface layer induced by the change of structures

  18. SEM studies of the structure of the gels prepared from untreated and radiation modified potato starch

    International Nuclear Information System (INIS)

    Cieśla, Krystyna; Sartowska, Bożena; Królak, Edward

    2015-01-01

    Potato starch was irradiated with a 60 Co gamma rays using doses of 5, 10, 20 and 30 kGy. Gels containing ca. 9.1% of starch were prepared by heating the starch suspensions in the heating chamber stabilized at 100 °C. Four procedures were applied for preparation of the samples in regard to SEM studies and the ability to observe the radiation effect by SEM was assessed for each method. Differences were observed between the SEM images recorded for the non-irradiated samples prepared using all the methods, and those irradiated. Images of the non-irradiated gels indicate generally a honey-comb structure, while smooth areas but with oriented fractures has appeared after irradiation. Modification of gel structure corresponds to the applied dose. The results were related to the process of gel formation (as observed by means of the hot stage microscope) to decrease in swelling power of the irradiated starch and to decreased viscosity of the resulting gels. It can be concluded that the differences in structural properties of gels shown by SEM result probably due to the better homogenization of the gels formed after radiation induced degradation. - Highlights: • Four procedures of the preservation of starch gels for SEM studies were applied. • The ability to observe the radiation effect by SEM was assessed for each method. • Dose dependent changes in the gel structure were discovered. • It was related to decrease in the swelling power and decreased viscosity of the gels. • A hot-stage microscope was applied in order to follow the gelatinization process

  19. A SEM-correlation of the anatomy of the vitreous body: making visible the invisible.

    Science.gov (United States)

    Jongebloed, W L; Humalda, D; Worst, J F

    1986-12-30

    The naked human vitreous (sclera, iris and cornea removed) suspended in water does not reveal inner structures. After ink injection into the vitreous, the presence of different compartments and the existence of cisterns becomes evident. A concept of the internal system of cisterns is given on the basis of stereoscopic-lightmicroscopic images. An attempt is made to correlate images of the complete vitreous body, obtained with a stereo-lightmicroscope, with images of segments of cisternal walls produced with a scanning electron-microscope (SEM). A comparison is made between SEM-images of the vitreous bodies of human and rabbit eyes.

  20. Neuropsicología de la demencia semántica

    OpenAIRE

    Andrade Quintero, Luz Helena

    2012-01-01

    La Demencia Semántica causa alteraciones en la capacidad para recordar el significado de las palabras, rostros y objetos, producto de atrofia asimétrica o bilateral de los lóbulos temporales anteriores. Clínicamente se han observado múltiples síndromes clínicos superpuestos con otras enfermedades degenerativas como la Afasia Primaria Progresiva y la Demencia tipo Alzheimer. El propósito de este estudio fue identificar alteraciones lingüísticas y semánticas en un grupo de pacientes con Demenci...

  1. SEM-EDX IDENTIFICATION OF PARTICLES FROM FOG IN AN INDUSTRIALLY POLLUTED REGION OF CZECH REPUBLIC

    Czech Academy of Sciences Publication Activity Database

    Stoyanova, V.; Shoumkova, A.; Fišák, Jaroslav; Tsacheva, Ts.

    Vol. II - BUA32, č. 1 (2010), s. 269-276 ISSN 1314-2704. [International Multidisciplinary Scientific GeoConference SGEM 2010 /10./. Albena, 20.06.2010-26.06.2010] Institutional research plan: CEZ:AV0Z30420517 Keywords : SEM-EDX * solid atmospheric pollutants * trace elements * heavy metals * Czech Republic Subject RIV: DG - Athmosphere Sciences, Meteorology http://www.ipc.bas.bg/PPages/Shoumkova/Publications/Articles/2010%20SEM-EDX%20identification%20of%20FP.pdf

  2. SEM examination and analysis of the interface character in surface modified aramid-epoxy composite

    International Nuclear Information System (INIS)

    Hussain, S.; Khan, M.B.; Hussain, R.

    2011-01-01

    The surface of Kevlar fibers is chemically modified by treatment with Phthalic anhydride (PA) and the effect is examined by SEM for the laser cut, three point bending and interlaminar shear delaminated surfaces. The surface modification improved the adhesion to epoxy resin that clearly leads to cohesive fracture as opposed to interfacial failure in the untreated specimen. SEM reveals marginal surface roughening of fibers without compromising their strength. The interface modification technique described in this paper is attractive thermodynamically as it does not compromise surface free energy of the polymer matrix or that of the fiber itself to enhance wet ability. (author)

  3. El adjetivo en el Nuevo Testamento: clasificación semántica

    OpenAIRE

    Romero González, Dámaris

    2011-01-01

    El adjetivo ha sido estudiado habitualmente desde el punto de vista del sustantivo, como una subclase de éste, ya que ambos poseen una morfología similar. Semánticamente, la mayoría de las gramáticas los clasifican según su capacidad para calificar o determinar al sustantivo, denominándolo calificativo y determinativo respectivamente. Dentro de esta clasificación, se han establecido subgrupos basados en criterios semánticos. Por tanto, el propósito de esta tesis es esbozar una nueva...

  4. SEM analysis of ionizing radiation effects in linear integrated circuits. [Scanning Electron Microscope

    Science.gov (United States)

    Stanley, A. G.; Gauthier, M. K.

    1977-01-01

    A successful diagnostic technique was developed using a scanning electron microscope (SEM) as a precision tool to determine ionization effects in integrated circuits. Previous SEM methods radiated the entire semiconductor chip or major areas. The large area exposure methods do not reveal the exact components which are sensitive to radiation. To locate these sensitive components a new method was developed, which consisted in successively irradiating selected components on the device chip with equal doses of electrons /10 to the 6th rad (Si)/, while the whole device was subjected to representative bias conditions. A suitable device parameter was measured in situ after each successive irradiation with the beam off.

  5. Wi-Fi Salvador: mapeamento colaborativo e redes sem fio no Brasil

    OpenAIRE

    Lemos, André; Pastor, Leonardo; Oliveira, Nelson

    2012-01-01

    O trabalho faz uma breve demonstração de políticas públicas para inclusão digital por meio da disponibilização do acesso à internet por meio de redes sem fio e discute a forma como as pessoas se relacionam com os lugares, de acordo com a existência ou inexistência de acessibilidade à internet. O objetivo é discutir o acesso à internet pelas redes sem fio no Brasil e, mais especificamente, na cidade de Salvador. Este trabalho é fruto de pesquisa realizada no âmbito do Grupo de Pesquisa em Cibe...

  6. Mapping the Complex Morphology of Cell Interactions with Nanowire Substrates Using FIB-SEM

    DEFF Research Database (Denmark)

    Wierzbicki, Rafal; Købler, Carsten; Jensen, Mikkel Ravn Boye

    2013-01-01

    Using high resolution focused ion beam scanning electron microscopy (FIB-SEM) we study the details of cell-nanostructure interactions using serial block face imaging. 3T3 Fibroblast cellular monolayers are cultured on flat glass as a control surface and on two types of nanostructured scaffold...... substrates made from silicon black (Nanograss) with low- and high nanowire density. After culturing for 72 hours the cells were fixed, heavy metal stained, embedded in resin, and processed with FIB-SEM block face imaging without removing the substrate. The sample preparation procedure, image acquisition...

  7. STEM mode in the SEM for the analysis of cellular sections prepared by ultramicrotome sectioning

    International Nuclear Information System (INIS)

    Hondow, N; Harrington, J; Brydson, R; Brown, A

    2012-01-01

    The use of the dual imaging capabilities of a scanning electron microscope fitted with a transmitted electron detector is highlighted in the analysis of samples with importance in the field of nanotoxicology. Cellular uptake of nanomaterials is often examined by transmission electron microscopy of thin sections prepared by ultramicrotome sectioning. Examination by SEM allows for the detection of artefacts caused by sample preparation (eg. nanomaterial pull-out) and the complementary STEM mode permits study of the interaction between nanomaterials and cells. Thin sections of two nanomaterials of importance in nanotoxicology (cadmium selenide quantum dots and single walled carbon nanotubes) are examined using STEM mode in the SEM.

  8. Marginal adaptation of a low-shrinkage silorane-based composite: A SEM-analysis

    DEFF Research Database (Denmark)

    Schmidt, Malene; Bindslev, Preben Hørsted; Poulsen, Sven

    2012-01-01

    shrinkage, has been marketed. Objective. To investigate whether reduced polymerization shrinkage improves the marginal adaptation of composite restorations. Material and methods. A total of 156 scanning electron microscopy (SEM) pictures (78 baseline, 78 follow-up) of the occlusal part of Class II......-casts of the restorations were used for SEM pictures at x 16 magnification. Pictures from baseline and follow-up (398 days, SD 29 days) were randomized and the examiner was blinded to the material and the age of the restoration. Stereologic measurements were used to calculate the length and the width of the marginal...

  9. Separating topographical and chemical analysis of nanostructure of polymer composite in low voltage SEM

    International Nuclear Information System (INIS)

    Wan, Q; Plenderleith, R A; Claeyssens, F; Rodenburg, C; Dapor, M; Rimmer, S

    2015-01-01

    The possibility of separating the topographical and chemical information in a polymer nano-composite using low-voltage SEM imaging is demonstrated, when images are acquired with a Concentric Backscattered (CBS) detector. This separation of chemical and topographical information is based on the different angular distribution of electron scattering which were calculated using a Monte Carlo simulation. The simulation based on angular restricted detection was applied to a semi-branched PNIPAM/PEGDA interpenetration network for which a linear relationship of topography SEM contrast and feature height data was observed. (paper)

  10. Cryo-Scanning Electron Microscopy (SEM) and Scanning Transmission Electron Microscopy (STEM)-in-SEM for Bio- and Organo-Mineral Interface Characterization in the Environment.

    Science.gov (United States)

    Wille, Guillaume; Hellal, Jennifer; Ollivier, Patrick; Richard, Annie; Burel, Agnes; Jolly, Louis; Crampon, Marc; Michel, Caroline

    2017-12-01

    Understanding biofilm interactions with surrounding substratum and pollutants/particles can benefit from the application of existing microscopy tools. Using the example of biofilm interactions with zero-valent iron nanoparticles (nZVI), this study aims to apply various approaches in biofilm preparation and labeling for fluorescent or electron microscopy and energy dispersive X-ray spectrometry (EDS) microanalysis for accurate observations. According to the targeted microscopy method, biofilms were sampled as flocs or attached biofilm, submitted to labeling using 4',6-diamidino-2-phenylindol, lectins PNA and ConA coupled to fluorescent dye or gold nanoparticles, and prepared for observation (fixation, cross-section, freezing, ultramicrotomy). Fluorescent microscopy revealed that nZVI were embedded in the biofilm structure as aggregates but the resolution was insufficient to observe individual nZVI. Cryo-scanning electron microscopy (SEM) observations showed nZVI aggregates close to bacteria, but it was not possible to confirm direct interactions between nZVI and cell membranes. Scanning transmission electron microscopy in the SEM (STEM-in-SEM) showed that nZVI aggregates could enter the biofilm to a depth of 7-11 µm. Bacteria were surrounded by a ring of extracellular polymeric substances (EPS) preventing direct nZVI/membrane interactions. STEM/EDS mapping revealed a co-localization of nZVI aggregates with lectins suggesting a potential role of EPS in nZVI embedding. Thus, the combination of divergent microscopy approaches is a good approach to better understand and characterize biofilm/metal interactions.

  11. 3D SEM for surface topography quantification – a case study on dental surfaces

    International Nuclear Information System (INIS)

    Glon, F; Flys, O; Lööf, P-J; Rosén, B-G

    2014-01-01

    3D analysis of surface topography is becoming a more used tool for industry and research. New ISO standards are being launched to assist in quantifying engineering surfaces. The traditional optical measuring instrumentation used for 3D surface characterization has been optical interferometers and confocal based instrumentation. However, the resolution here is limited in the lateral dimension to the wavelength of visible light to about 500 nm. The great advantage using the SEM for topography measurements is the high flexibility to zoom from low magnifications and locating interesting areas to high magnification of down to nanometer large surface features within seconds. This paper presents surface characterization of dental implant micro topography. 3D topography data was created from SEM images using commercial photogrammetric software. A coherence scanning interferometer was used for reference measurements to compare with the 3D SEM measurements on relocated areas. As a result of this study, measurements emphasizes that the correlation between the accepted CSI measurements and the new technology represented by photogrammetry based on SEM images for many areal characterization parameters are around or less than 20%. The importance of selecting sampling and parameter sensitivity to varying sampling is high-lighted. Future work includes a broader study of limitations of the photogrammetry technique on certified micro-geometries and more application surfaces at different scales

  12. Latent vs. Observed Variables : Analysis of Irrigation Water Efficiency Using SEM and SUR

    NARCIS (Netherlands)

    Tang, Jianjun; Folmer, Henk

    In this paper we compare conceptualising single factor technical and allocative efficiency as indicators of a single latent variable, or as separate observed variables. In the former case, the impacts on both efficiency types are analysed by means of structural equationmodeling (SEM), in the latter

  13. 3D reconstruction of SEM images by use of optical photogrammetry software.

    Science.gov (United States)

    Eulitz, Mona; Reiss, Gebhard

    2015-08-01

    Reconstruction of the three-dimensional (3D) surface of an object to be examined is widely used for structure analysis in science and many biological questions require information about their true 3D structure. For Scanning Electron Microscopy (SEM) there has been no efficient non-destructive solution for reconstruction of the surface morphology to date. The well-known method of recording stereo pair images generates a 3D stereoscope reconstruction of a section, but not of the complete sample surface. We present a simple and non-destructive method of 3D surface reconstruction from SEM samples based on the principles of optical close range photogrammetry. In optical close range photogrammetry a series of overlapping photos is used to generate a 3D model of the surface of an object. We adapted this method to the special SEM requirements. Instead of moving a detector around the object, the object itself was rotated. A series of overlapping photos was stitched and converted into a 3D model using the software commonly used for optical photogrammetry. A rabbit kidney glomerulus was used to demonstrate the workflow of this adaption. The reconstruction produced a realistic and high-resolution 3D mesh model of the glomerular surface. The study showed that SEM micrographs are suitable for 3D reconstruction by optical photogrammetry. This new approach is a simple and useful method of 3D surface reconstruction and suitable for various applications in research and teaching. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Hacia una visión generativista de la semántica lexical

    Directory of Open Access Journals (Sweden)

    Morales A. Bernardo

    1992-06-01

    Full Text Available

    Uno de los objetivos de la teoría semántica de una lengua natural es dar información satisfactoria sobre el significado de las formas lingüísticas. Consideramos que de éstas, las de mayor  importancia significativa son la palabra, la oración y el texto. La palabra, porque en virtud de su compleja estructura semántica y psicológica funciona como el principal medio para la abstracción y conformación de los conceptos destinados para la comunicación; la oración, porque es la unidad de la lengua viva que expresa relaciones de conceptos; el texto, porque es la explicitación del pensamiento en la interacción humana. Las semánticas lexical, oracional y textual son los tres grandes capítulos de la semántica lingüística.


  15. Surface topography characterization using 3D stereoscopic reconstruction of SEM images

    Science.gov (United States)

    Vedantha Krishna, Amogh; Flys, Olena; Reddy, Vijeth V.; Rosén, B. G.

    2018-06-01

    A major drawback of the optical microscope is its limitation to resolve finer details. Many microscopes have been developed to overcome the limitations set by the diffraction of visible light. The scanning electron microscope (SEM) is one such alternative: it uses electrons for imaging, which have much smaller wavelength than photons. As a result high magnification with superior image resolution can be achieved. However, SEM generates 2D images which provide limited data for surface measurements and analysis. Often many research areas require the knowledge of 3D structures as they contribute to a comprehensive understanding of microstructure by allowing effective measurements and qualitative visualization of the samples under study. For this reason, stereo photogrammetry technique is employed to convert SEM images into 3D measurable data. This paper aims to utilize a stereoscopic reconstruction technique as a reliable method for characterization of surface topography. Reconstructed results from SEM images are compared with coherence scanning interferometer (CSI) results obtained by measuring a roughness reference standard sample. This paper presents a method to select the most robust/consistent surface texture parameters that are insensitive to the uncertainties involved in the reconstruction technique itself. Results from the two-stereoscopic reconstruction algorithms are also documented in this paper.

  16. Characterisation of early medieval frescoes by {mu}-PIXE, SEM and Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, A. E-mail: zucc@ge.infn.it; Prati, P.; Bouquillon, A.; Giuntini, L.; Massi, M.; Migliori, A.; Cagnana, A.; Roascio, S

    2004-06-01

    We have studied the VIII-IX century frescoes of the Longobard temple of Cividale del Friuli in Italy with noninvasive sampling and, for the first time in such a context, with high chemical and spatial sensitivity techniques (PIXE, SEM and Raman). Results demonstrate richness of manufacturing details and integrate in a substantial way the historic and artistic framework of this early medieval monument.

  17. 78 FR 50079 - Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed...

    Science.gov (United States)

    2013-08-16

    ... DEPARTMENT OF THE INTERIOR Bureau of Safety and Environmental Enforcement [Docket ID BSEE-2013-0005; OMB Control Number 1014-0017: 134E1700D2 EEEE500000 ET1SF0000.DAQ000] Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed Collection; Comment Request...

  18. MORPHOLOGICAL ASPECTS OF HUMAN LENS CAPSULES - A COMPARATIVE LM, SEM AND TEM EXAMINATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; LOS, LI; VANDERVEEN, G; WORST, JGF

    1991-01-01

    Lens capsules of patients of advanced age, obtained after extracapsular cataract surgery, were carefully prepared for a combined LM, TEM and SEM investigation, after preliminary washing and mounting onto a holder in a buffer solution. After pre-fixation with GA, samples were postfixed for LM/TEM and

  19. HUMAN CAPSULE EPITHELIAL-CELL DEGENERATION A LM, SEM AND TEM INVESTIGATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; WORST, JGF

    1993-01-01

    The degeneration of the capsule epithelium of cataractous lenses has been studied with LM, SEM on TEM with emphases on TEM. The observed degeneration of the epithelial cells can be described as follows: The cell nucleus becomes picnotic and desintegrates as result of change of the chromatin.

  20. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation.

    OpenAIRE

    Siragusa, Martha; Racciatti, Gabriela; García, María

    2007-01-01

    Recibido: Marzo 2007 Aceptado: Julio 2007 Siragusa, Martha; Racciatti, Gabriela y García, María. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation. Electronic Journal of Endodontics Rosario [Online], Volumen 2 Número 13. [octubre 2007]. http://www.endojournal.com.ar/journal/index.php/ejer/article/view/44. ISSN 1666-6143.

  1. Integration of Correlative Raman microscopy in a dual beam FIB-SEM J. of Raman Spectroscopy

    NARCIS (Netherlands)

    Timmermans, Frank Jan; Liszka, B.; Lenferink, Aufrid T.M.; van Wolferen, Hendricus A.G.M.; Otto, Cornelis

    2016-01-01

    We present an integrated confocal Raman microscope in a focused ion beam scanning electron microscope (FIB SEM). The integrated system enables correlative Raman and electron microscopic analysis combined with focused ion beam sample modification on the same sample location. This provides new

  2. Characterisation of early medieval frescoes by μ-PIXE, SEM and Raman spectroscopy

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Prati, P.; Bouquillon, A.; Giuntini, L.; Massi, M.; Migliori, A.; Cagnana, A.; Roascio, S.

    2004-01-01

    We have studied the VIII-IX century frescoes of the Longobard temple of Cividale del Friuli in Italy with noninvasive sampling and, for the first time in such a context, with high chemical and spatial sensitivity techniques (PIXE, SEM and Raman). Results demonstrate richness of manufacturing details and integrate in a substantial way the historic and artistic framework of this early medieval monument

  3. The Great War and Remembrance in Jose Leon Machado's "Memoria das Estrelas sem Brilho"

    Science.gov (United States)

    Azevedo, Milton M.

    2011-01-01

    This article analyzes Jose Leon Machado's novel, "Memoria das Estrelas sem Brilho," as a multilayered historical novel in which a war story provides a background for comments on aspects of early twentieth-century Portuguese society, such as male bonding, religion, sexual mores, and social stratification. (Contains 11 notes.)

  4. Cryo-SEM studies of latex/ceramic nanoparticle coating microstructure development.

    Science.gov (United States)

    Luo, Hui; Scriven, L E; Francis, Lorraine F

    2007-12-15

    Cryogenic scanning electron microscopy (cryo-SEM) was used to investigate microstructure development of composite coatings prepared from dispersions of antimony-doped tin oxide (ATO) nanoparticles (approximately 30 nm) or indium tin oxide (ITO) nanoparticles (approximately 40 nm) and latex particles (polydisperse, D(v): approximately 300 nm). Cryo-SEM images of ATO/latex dispersions as-frozen show small clusters of ATO and individual latex particles homogeneously distribute in a frozen water matrix. In contrast, cryo-SEM images of ITO/latex dispersions as-frozen show ITO particles adsorb onto latex particle surfaces. Electrostatic repulsion between negatively charged ATO and negatively charged latex particles stabilizes the ATO/latex dispersion, whereas in ITO/latex dispersion, positively charged ITO particles are attracted onto surfaces of negatively charged latex particles. These results are consistent with calculations of interaction potentials from past research. Cryo-SEM images of frozen and fractured coatings reveal that both ceramic nanoparticles and latex become more concentrated as drying proceeds; larger latex particles consolidate with ceramic nanoparticles in the interstitial spaces. With more drying, compaction flattens the latex-latex particle contacts and shrinks the voids between them. Thus, ceramic nanoparticles are forced to pack closely in the interstitial spaces, forming an interconnected network. Finally, latex particles partially coalesce at their flattened contacts, thereby yielding a coherent coating. The research reveals how nanoparticles segregate and interconnect among latex particles during drying.

  5. Combination of FTIR and SEM for Identifying Freshwater-Cultured Pearls from Different Quality

    Science.gov (United States)

    Satitkune, Somruedee; Monarumit, Natthapong; Boonmee, Chakkrich; Phlayrahan, Aumaparn; Promdee, Kittiphop; Won-in, Krit

    2016-03-01

    The freshwater-cultured pearl ( Chamberlainia hainesiana species) is an organic gemstone mainly composed of calcium carbonate mineral including calcite, aragonite and vaterite phases. Generally, the quality of freshwater-cultured pearl is based on its luster. The high luster pearl is full of the aragonite phase without vaterite phase. On the other hand, the low luster pearl consists of aragonite and vaterite phases. These data could be proved by the Fourier Transform Infrared (FTIR) spectroscopy combined with the scanning electron microscopy (SEM). As the results, the high luster pearl similarly shows the FTIR spectrum of aragonite phase, and also, it shows the hexagonal shape of aragonite for the SEM image. On the other hand, the FTIR spectrum of low luster pearl has been pointed to the mixture component among aragonite and vaterite phases, and based on the SEM image; the irregular form is also interpreted to the mixture of aragonite and vaterite phases. This research concludes that the quality of freshwater-cultured pearls can be identified by the combination data of FTIR spectra and SEM images. These techniques are suitable for applied gemology.

  6. MICROORGANISMS FOUND IN SECONDARY CATARACT MATERIAL OF ECCE PATIENTS, A STUDY WITH SEM AND TEM

    NARCIS (Netherlands)

    KALICHARAN, D; JONGEBLOED, WL; LOS, LI; WORST, JGF

    1993-01-01

    Globular secondary cataract material, removed from 24 patients with ECCE after ophthalmic cleaning of the anterior capsule, were investigated with SEM and TEM. Besides spherical, somewhat oval shaped bodies of various shape and size comparable with those found in cataractous lenses, (an)aerobic

  7. (AN)AEROBIC BACTERIA FOUND IN SECONDARY-CATARACT MATERIAL - A SEM/TEM STUDY

    NARCIS (Netherlands)

    KALICHARAN, D; JONGEBLOED, WL; LOS, LI; WORST, JGF

    1992-01-01

    Twentyfour patients, who had marked reduction of vision due to secondary-cataract developed after an ECCE, were treated by surgical cleaning of the posterior lens capsule. During this procedure globular secondary-cataract material was removed and collected for morphological examination by SEM and

  8. Controlled dehydration of a biological sample using an alternative form of environmental SEM

    Czech Academy of Sciences Publication Activity Database

    Neděla, Vilém

    2010-01-01

    Roč. 237, č. 1 (2010), s. 7-11 ISSN 0022-2720 Institutional research plan: CEZ:AV0Z20650511 Keywords : biological sample * dehydration * environmental SEM * AQUASEM II * hydration system Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.872, year: 2010

  9. Fractionation of Pb in Soil of Abandoned Pb Mine by SEM-EDX and ...

    African Journals Online (AJOL)

    Therefore, scanning electron microscopy coupled with energy dispersive X-ray spectrometer (SEM-EDX) were used for the identification of fractional forms of Pb that are liable to leach out/down from the soil matrix of the abandoned mine site to surface-andunderground water bodies of the nearby localities, and to determine ...

  10. A Comparative SEM-EDS Elemental Composition of Mud in Coastal ...

    African Journals Online (AJOL)

    The present study was aimed to understand the comparative abundance and source of elemental constituents in mud of four coastal shrimp farming areas, Vunh Tau (VT), Nha Trang (NT), Da Nang (DN) and Hue (HU) in Viet Nam using SEM-EDS analysis. Mud samples were collected from shrimp farming coastal zones ...

  11. Recent Advances on In Situ SEM Mechanical and Electrical Characterization of Low-Dimensional Nanomaterials

    Directory of Open Access Journals (Sweden)

    Chenchen Jiang

    2017-01-01

    Full Text Available In the past decades, in situ scanning electron microscopy (SEM has become a powerful technique for the experimental study of low-dimensional (1D/2D nanomaterials, since it can provide unprecedented details for individual nanostructures upon mechanical and electrical stimulus and thus uncover the fundamental deformation and failure mechanisms for their device applications. In this overview, we summarized recent developments on in situ SEM-based mechanical and electrical characterization techniques including tensile, compression, bending, and electrical property probing on individual nanostructures, as well as the state-of-the-art electromechanical coupling analysis. In addition, the advantages and disadvantages of in situ SEM tests were also discussed with some possible solutions to address the challenges. Furthermore, critical challenges were also discussed for the development and design of robust in situ SEM characterization platform with higher resolution and wider range of samples. These experimental efforts have offered in-depth understanding on the mechanical and electrical properties of low-dimensional nanomaterial components and given guidelines for their further structural and functional applications.

  12. A Sandwich-Type Standard Error Estimator of SEM Models with Multivariate Time Series

    Science.gov (United States)

    Zhang, Guangjian; Chow, Sy-Miin; Ong, Anthony D.

    2011-01-01

    Structural equation models are increasingly used as a modeling tool for multivariate time series data in the social and behavioral sciences. Standard error estimators of SEM models, originally developed for independent data, require modifications to accommodate the fact that time series data are inherently dependent. In this article, we extend a…

  13. Are the evidences of forensic entomology preserved in ethanol suitable for SEM studies?

    Science.gov (United States)

    López-Esclapez, Raquel; García, María-Dolores; Arnaldos, María-Isabel; Presa, Juan José; Ubero-Pascal, Nicolás

    2014-07-01

    In forensic practice, the use of arthropod evidences to estimate the postmortem interval is a very good approach when the elapsed time from death is long, but it requires the correct identification of the specimens. This is a crucial step, not always easy to achieve, in particular when dealing with immature specimens. In this case, scanning electronic microscopy (SEM) can be useful, but the techniques used to preserve specimens in forensic practice are usually different from those used to prepare specimens for SEM studies. To determine whether forensic evidences preserving techniques are also compatible with SEM analysis, we have compared specimens of all the immature stages of Calliphora vicina Robineau-Desvoidy, 1830 (Diptera, Calliphoridae) preserved in 70% ethanol, with others prepared with aldehydic fixative techniques that are more appropriate for SEM studies. At the same time, two drying techniques have also been compared with both fixative techniques, the critical point drying and air-drying following with hexamethyldisilizane treatment (HMDS). Our results indicate that there are not basis against recommending the use of ethanol to preserve forensic entomological evidences and that both drying methods appear to offer good results for second and third instar larvae, although HMDS behaves better with eggs and pupae. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Field emission scanning electron microscopy (FE-SEM) as an approach for nanoparticle detection inside cells

    Czech Academy of Sciences Publication Activity Database

    Havrdová, M.; Poláková, K.; Skopalík, J.; Vůjtek, M.; Mokdad, A.; Homolková, M.; Tuček, J.; Nebesářová, Jana; Zbořil, R.

    2014-01-01

    Roč. 67, DEC 2014 (2014), s. 149-154 ISSN 0968-4328 Institutional support: RVO:60077344 Keywords : Field emission scanning electronmicroscopy (FE-SEM) * Stem cells * Iron oxide nanoparticles * Cellular morphology * Endosomes * Cell uptake Subject RIV: FD - Oncology ; Hematology Impact factor: 1.988, year: 2014

  15. Surface ultrastructural (SEM) characteristics of oropharyngeal cavity of house sparrow (Passer domesticus).

    Science.gov (United States)

    Abumandour, Mohamed M A

    2018-06-01

    The focus of the present study is to provide a full morphological description of the oropharyngeal cavity of the house sparrow. The head of six birds was prepared for gross examination and by stereo and electron microscopy. The bifid lingual apex has multiple long, rostrally directed needle-like processes. The lateral border of the apex carries rostromedially directed needle-like processes. The dorsal lingual surface of the apex and body carries numerous caudomedially directed filiform papillae and many orifices of lingual salivary glands. The lingual body is divided into two parts: rostral and caudal. The caudal part is divided into two laterally elevated regions by a median groove, while the rostral part is bounded laterally by a rostrodorsally directed papillary row, which on SEM is formed from two rows. On SEM, the lingual root has many orifices of posterior salivary glands. The pharyngeal papillary row is located at the caudal border of the laryngeal mound, but this single papillary row is formed from two rows at SEM magnification. The laryngeal cleft continues caudally as a laryngeal fissure bounded by two longitudinal rows of caudally directed papillae; at high SEM magnification, this fissure is divided into two halves by a median ridge which carries caudally directed papillae on its posterior part. The choanal cleft proceeds rostrally by the median tubercle. There are a small number of orifices of palatine salivary glands. The morphological characters of the oropharyngeal cavity of the sparrow confirm its adaptation to surrounding environmental conditions and available food particles.

  16. Effects of Missing Data Methods in SEM under Conditions of Incomplete and Nonnormal Data

    Science.gov (United States)

    Li, Jian; Lomax, Richard G.

    2017-01-01

    Using Monte Carlo simulations, this research examined the performance of four missing data methods in SEM under different multivariate distributional conditions. The effects of four independent variables (sample size, missing proportion, distribution shape, and factor loading magnitude) were investigated on six outcome variables: convergence rate,…

  17. Study of Morphological Changes of The Lime Putties During Maturing by SEM/ESEM

    Czech Academy of Sciences Publication Activity Database

    Navrátilová, Eva; Neděla, Vilém

    2017-01-01

    Roč. 23, S1 (2017), s. 2186-2187 ISSN 1431-9276 R&D Projects: GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : SEM * ESEM * morphological changes * lime putties Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering OBOR OECD: Civil engineering Impact factor: 1.891, year: 2016

  18. Recent Advances on In Situ SEM Mechanical and Electrical Characterization of Low-Dimensional Nanomaterials.

    Science.gov (United States)

    Jiang, Chenchen; Lu, Haojian; Zhang, Hongti; Shen, Yajing; Lu, Yang

    2017-01-01

    In the past decades, in situ scanning electron microscopy (SEM) has become a powerful technique for the experimental study of low-dimensional (1D/2D) nanomaterials, since it can provide unprecedented details for individual nanostructures upon mechanical and electrical stimulus and thus uncover the fundamental deformation and failure mechanisms for their device applications. In this overview, we summarized recent developments on in situ SEM-based mechanical and electrical characterization techniques including tensile, compression, bending, and electrical property probing on individual nanostructures, as well as the state-of-the-art electromechanical coupling analysis. In addition, the advantages and disadvantages of in situ SEM tests were also discussed with some possible solutions to address the challenges. Furthermore, critical challenges were also discussed for the development and design of robust in situ SEM characterization platform with higher resolution and wider range of samples. These experimental efforts have offered in-depth understanding on the mechanical and electrical properties of low-dimensional nanomaterial components and given guidelines for their further structural and functional applications.

  19. Does your SEM really tell the truth?--How would you know? Part 1.

    Science.gov (United States)

    Postek, Michael T; Vladár, András E

    2013-01-01

    The scanning electron microscope (SEM) has gone through a tremendous evolution to become a critical tool for many and diverse scientific and industrial applications. The high resolution of the SEM is especially suited for both qualitative and quantitative applications especially for nanotechnology and nanomanufacturing. Quantitatively, measurement, or metrology is one of the main uses. It is likely that one of the first questions asked before even the first scanning electron micrograph was ever recorded was: "… how big is that?" The quality of that answer has improved a great deal over the past few years especially since today these instruments are being used as a primary measurement tool on semiconductor processing lines to monitor the manufacturing processes. The well-articulated needs of semiconductor production prompted a rapid evolution of the instrument and its capabilities. Over the past 20 years or so, instrument manufacturers, through substantial semiconductor industry investment of research and development (R&D) money, have vastly improved the performance of these instruments. All users have benefited from this investment, especially where quantitative measurements with an SEM are concerned. But, how good are these data? This article discusses some of the most important aspects and larger issues associated with imaging and measurements with the SEM that every user should know, and understand before any critical quantitative work is attempted. © Wiley Periodicals, Inc.

  20. SD-SEM: sparse-dense correspondence for 3D reconstruction of microscopic samples.

    Science.gov (United States)

    Baghaie, Ahmadreza; Tafti, Ahmad P; Owen, Heather A; D'Souza, Roshan M; Yu, Zeyun

    2017-06-01

    Scanning electron microscopy (SEM) imaging has been a principal component of many studies in biomedical, mechanical, and materials sciences since its emergence. Despite the high resolution of captured images, they remain two-dimensional (2D). In this work, a novel framework using sparse-dense correspondence is introduced and investigated for 3D reconstruction of stereo SEM images. SEM micrographs from microscopic samples are captured by tilting the specimen stage by a known angle. The pair of SEM micrographs is then rectified using sparse scale invariant feature transform (SIFT) features/descriptors and a contrario RANSAC for matching outlier removal to ensure a gross horizontal displacement between corresponding points. This is followed by dense correspondence estimation using dense SIFT descriptors and employing a factor graph representation of the energy minimization functional and loopy belief propagation (LBP) as means of optimization. Given the pixel-by-pixel correspondence and the tilt angle of the specimen stage during the acquisition of micrographs, depth can be recovered. Extensive tests reveal the strength of the proposed method for high-quality reconstruction of microscopic samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. On some contrast reversals in SEM: Application to metal/insulator systems

    International Nuclear Information System (INIS)

    Cazaux, Jacques

    2008-01-01

    Contrast changes of SEM images with experimental conditions (beam energy, angle of detection, etc.) are analyzed by combining physical arguments based on secondary electron emission (SEE) to instrumental arguments involving detection. Possible occurrences of contrast reversals are explored to illustrate these changes in a striking manner. Deduced from SEE yield data, simulated SEM images show a material contrast reversal for a Pt/quartz specimen, a result partly supported by real images of a Cr/quartz integrated circuit. A shift of reversal energy with the detector's position is deduced from a difference in secondary electrons (SE) angular distributions between metals and insulators. Similarly, changes of topographic contrast with detection conditions, specimen composition and angle of tilt are investigated and a possible contrast reversal is again indicated. Finally, it is shown how charging contrast deduced from the expected evolution of SEE yield during irradiation is amplified by in-lens detection: a point illustrated by a contrast reversal of images of SiC particles. The main application concerns a proper interpretation of SEM images that is essential in the investigation of devices obtained from lithographic processes. The discussion on material contrast outlines the difficulty in generalizing the present analysis based on published data and experimental strategies based on implementing specific attachments in the SEM or on biasing the specimen holder are suggested.

  2. Human cardiac telocytes: 3D imaging by FIB-SEM tomography.

    Science.gov (United States)

    Cretoiu, D; Hummel, E; Zimmermann, H; Gherghiceanu, M; Popescu, L M

    2014-11-01

    Telocyte (TC) is a newly identified type of cell in the cardiac interstitium (www.telocytes.com). TCs are described by classical transmission electron microscopy as cells with very thin and long telopodes (Tps; cellular prolongations) having podoms (dilations) and podomers (very thin segments). TCs' three-dimensional (3D) morphology is still unknown. Cardiac TCs seem to be particularly involved in long and short distance intercellular signalling and, therefore, their 3D architecture is important for understanding their spatial connections. Using focused ion beam scanning electron microscopy (FIB-SEM) we show, for the first time, the whole ultrastructural anatomy of cardiac TCs. 3D reconstruction of cardiac TCs by FIB-SEM tomography confirms that they have long, narrow but flattened (ribbon-like) telopodes, with humps generated by the podoms. FIB-SEM tomography also confirms the network made by TCs in the cardiac interstitium through adherens junctions. This study provides the first FIB-SEM tomography of a human cell type. © 2014 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  3. Maximum Likelihood Dynamic Factor Modeling for Arbitrary "N" and "T" Using SEM

    Science.gov (United States)

    Voelkle, Manuel C.; Oud, Johan H. L.; von Oertzen, Timo; Lindenberger, Ulman

    2012-01-01

    This article has 3 objectives that build on each other. First, we demonstrate how to obtain maximum likelihood estimates for dynamic factor models (the direct autoregressive factor score model) with arbitrary "T" and "N" by means of structural equation modeling (SEM) and compare the approach to existing methods. Second, we go beyond standard time…

  4. Prescriptive Statements and Educational Practice: What Can Structural Equation Modeling (SEM) Offer?

    Science.gov (United States)

    Martin, Andrew J.

    2011-01-01

    Longitudinal structural equation modeling (SEM) can be a basis for making prescriptive statements on educational practice and offers yields over "traditional" statistical techniques under the general linear model. The extent to which prescriptive statements can be made will rely on the appropriate accommodation of key elements of research design,…

  5. Does your SEM really tell the truth? How would you know? Part 2.

    Science.gov (United States)

    Postek, Michael T; Vladár, András E; Purushotham, Kavuri P

    2014-01-01

    The scanning electron microscope (SEM) has gone through a tremendous evolution to become indispensable for many and diverse scientific and industrial applications. The improvements have significantly enriched and augmented the overall SEM performance and have made the instrument far easier to operate. But, the ease of operation also might lead, through operator complacency, to poor results. In addition, the user friendliness has seemingly reduced the need for thorough operator training for using these complex instruments. One might then conclude that the SEM is just a very expensive digital camera or another peripheral device for a computer. Hence, a person using the instrument may be lulled into thinking that all of the potential pitfalls have been eliminated and they believe everything they see on the micrograph is always correct. But, this may not be the case. An earlier paper (Part 1), discussed some of the potential issues related to signal generation in the SEM, instrument calibration, electron beam interactions and the need for physics-based modeling to understand the actual image formation mechanisms. All these were summed together in a discussion of how these issues effect measurements made with the instrument. This second paper discusses another major issue confronting the microscopist: electron-beam-induced specimen contamination. Over the years, NIST has done a great deal of research into the issue of sample contamination and its removal and elimination and some of this work is reviewed and discussed here. © 2013 Wiley Periodicals, Inc.

  6. Sem-observation of developing plant organs using deep-frozen specimens

    NARCIS (Netherlands)

    NN,

    1982-01-01

    The SEM-observation of plant material normally requires dehydrated, dry specimens coated with carbon or metal. Unfortunately, the standard drying methods (including the critical-point-drying-technique) often cause shrinking and deformation of the specimen surface; therefore, SEMstudies on plant

  7. SEM observations of particle track membrane surfaces modificated using plasma treatment

    International Nuclear Information System (INIS)

    Sartowska, B.; Buczkowski, M.; Starosta, W.

    2003-01-01

    This work presents results of scanning electron microscopy (SEM) observations of 0.4 μm membranes after plasma treatment with different parameters. The morphology changes at the surfaces and at the pore walls were observed. The character of changes in the membrane parameters according to the process conditions was determined

  8. Trace metals in floodplain lake sediments : SEM/AVS as indicator of bioavailability and ecological effects

    NARCIS (Netherlands)

    Griethuysen, van C.

    2006-01-01

    This thesis addresses the geochemical aspects of AVS (Acid Volatile Sulfide) and SEM (Simultaneously Extracted Metals) in floodplain lake sediment, its spatial distribution in floodplain lakes and dynamics over time, the link with effects on single species (bioassays), as well as the impact of

  9. Dimensional verification of high aspect micro structures using FIB-SEM

    DEFF Research Database (Denmark)

    Zhang, Yang; Hansen, Hans Nørgaard

    2013-01-01

    -SEM) assisted by Spip®. The micro features are circular holes 10μm in diameter and 20μm deep, with a 20μm pitch. Various inspection methods were attempted to obtain dimensional information. Due to the dimension, neither optical instrument nor atomic force microscope (AFM) was capable to perform the measurement...

  10. Correlação entre hipótese diagnóstica e laudo de tomografia axial computadorizada craniana Correlation between diagnostic hypothesis and result of cranial computed axial tomography

    Directory of Open Access Journals (Sweden)

    Edison Matos Nóvak

    2001-09-01

    Full Text Available Para avaliar a utilização da tomografia axial computadorizada craniana (TC em nosso meio, analisamos as solicitações de 367 exames consecutivos no período compreendido entre 07/1995 e 07/1996. Houve ampla variação da faixa etária, com média de 31,7 ± 22,9 anos. As especialidades que mais solicitaram o exame foram: Neurologia (36,2%, Pronto Atendimento (17,4%, Neuropediatria (16,9% e Clínica Médica (5,9%. As indicações mais frequentes para o exame foram: convulsão (30%, cefaléia (26,2%, déficit motor (20,2% e redução do nível de consciência (16,9%. As "hipóteses" aventadas com maior frequência foram: afastar lesão estrutural (9,0%, acidente vascular não discriminado (8,2% e neurocisticercose (8,2%. O laudo da TC foi normal em 50,4% dos exames. Os laudos anormais mais frequentes foram: hidrocefalia (5,4%, acidente vascular isquêmico (5,4% e neoplasia (3,5%. As maiores taxas de achados normais foram encontradas nas "hipóteses" de cefaléia (94,4%, convulsão (71,4% e afastar lesão estrutural (66,7%. Os maiores índices de acerto entre hipótese e laudo foram encontrados nas situações de "afastar lesões estruturais" (66,7%, hidrocefalia (50%, acidente vascular cerebral isquêmico (50% e hematoma (50%. Concluimos que a utilização de um recurso auxiliar de diagnóstico como a TC cumpre melhor ainda a sua função se o requisitante do exame preencher com clareza e detalhamento o pedido do exame.The use of computed axial tomography (CT in the investigation of neurologic disorders is attractive for his disponibility in the health services. However, the indications of the exam and the correlation with the clinical features has not been frequently studied. We study correlation between the requests of CT and the findings reported by the radiologist, in 367 exams performed from 07/1995 to 07/ 1996. The mean age was 31.7 ± 22.9 years. The CT were requested in decrescent order of frequency by the Services of Neurology (36

  11. Computed tomography scan of the head in patients with migraine or tension-type headache Tomografia computadorizada do crânio em pacientes com migrânea ou cefaléia tensional

    Directory of Open Access Journals (Sweden)

    Marcelo Moraes Valença

    2002-09-01

    Full Text Available A retrospective study was performed in order to evaluate the frequency of abnormalities found by computed tomography (CT scan of the head in 78 patients with migraine or tension-type headache. In the present study CT scan was normal in 61.5% of the patients with migraine or tension-type headache. A number of abnormalities were encountered in more than one third of the patients studied, including inflammatory sinus disease (19.2%, cysticercosis (3.9%, unruptuted cerebral aneurysm (2.6%, basilar impression (2.6%, intracranial lipoma (2.6%, arachnoid cyst (2.6%, empty sella (2.6%, intracranial neoplasm (2.6%, and others (2.6%. None of these lesions were symptomatic or responsible by the headache picture, therefore, considered incidental findings. In conclusion, the fortuitous encounter of some abnormalities on CT scan of the head is often higher than what we could predict in patients suffering migraine or tension-type headache. We briefly discuss clinical, epidemiologic, and practical management of some of the abnormalities detected by CT scan as well as the indication to request a neuroimaging investigation.Um estudo retrospectivo foi realizado visando avaliar a frequência de anormalidades encontradas durante a realização de estudo por tomografia computadorizada (TC em 78 pacientes com migrânea ou cefaléia do tipo tensional. A TC foi normal em 61,5% dos pacientes examinados. Em um terço dos pacientes estudados foram detectadas anormalidades, como doença inflamatória dos seios paranasais (19,2%, cisticercose (3,9%, aneurisma cerebral não-roto (2,6%, impressão basilar (2,6%, lipoma intracraniano (2,6%, cisto aracnoideo (2,6%, sela vazia (2,6%, neoplasia intracraniana (2,6% e outras afecções (2,6%. Nenhuma destas lesões era sintomática (achado incidental. Concluindo, o encontro fortuito de algumas anormalidades na TC é frequentemente mais elevado do que se prediz em pacientes com cefaléia primária. Nós discutimos brevemente alguns

  12. Immediate adverse reactions to intravenous iodinated contrast media in computed tomography Reacciones adversas inmediatas al contraste yodado intravenoso en tomografía computarizada Reações adversas imediatas ao contraste iodado intravenoso em tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Beatriz Cavalcanti Juchem

    2007-02-01

    ório-descritiva, de caráter não experimental, com o objetivo de conhecer as reações adversas imediatas ao contraste iodado intravenoso em pacientes hospitalizados, submetidos a tomografia computadorizada num hospital-escola no Sul do Brasil. Durante o período de estudo, todas as reações adversas manifestaram-se na intensidade leve, com freqüência de 12,5% com o uso de contraste iodado iônico e 1% com contraste não iônico. Extravasamento do meio radiopaco ocorreu em 2,2% das injeções em veia periférica, não havendo complicações em nenhum dos casos. Os resultados encontram-se dentro dos limites citados na literatura internacional e sugere-se que os serviços de tomografia conheçam as próprias taxas de reações adversas ao contraste iodado e as condições em que elas ocorrem, a fim de obter evidências para a avaliação dos respectivos processos assistenciais.

  13. Priming of pioneer tree Guazuma ulmifolia (Malvaceae seeds evaluated by an automated computer image analysis Condicionamento fisiológico de sementes da árvore pioneira Guazuma ulmifolia (Malvaceae avaliado por análise computadorizada de imagens

    Directory of Open Access Journals (Sweden)

    Pedro Henrique Santin Brancalion

    2010-01-01

    e em PEG 8000 (-0,8 MPa por 56 e 88 h a 20ºC, atingindo teor de água de, aproximadamente, 30%. Metade das amostras de cada tratamento foi secada até atingir teor de água próximo ao inicial (7,2%; em seguida, avaliou-se o desempenho das sementes condicionadas submetidas ao não à secagem, além de sementes não condicionadas (testemunha, quanto à germinação (porcentagem e velocidade e o vigor (condutividade elétrica dos exudatos das sementes. A porcentagem e a velocidade de emergência de plântulas foram avaliadas em condições de casa de vegetação, enquanto que o comprimento de plântulas e a uniformidade de desenvolvimento das plântulas foram estimados usando o software de análise computadorizada de imagens de plântulas SVIS®. As sementes condicionadas fisiologicamente apresentaram potencial fisiológico superior, demonstrado principalmente pelos resultados da análise de imagens. Assim, as sementes condicionadas em água durante 16 h ou em PEG durante 88 h, ambas não submetidas à secagem subsequente, e as condicionadas em PEG durante 56 h e submetidas a secagem, beneficiaram o desempenho germinativo de G. ulmifolia. Sugere-se que esses tratamentos são promissores para aumentar a eficiência de estabelecimento de estande dessa espécie via semeadura direta em programas de restauração ecológica.

  14. Frequency of suspected cases of neurocysticercosis detected by computed skull tomography in Santa Maria, RS, Brazil Freqüência de casos suspeitos de neurocisticercose em tomografias computadorizadas de crânio em Santa Maria, RS, Brasil

    Directory of Open Access Journals (Sweden)

    José Edson Paz da SILVA

    2000-02-01

    Full Text Available Due to the lack of studies about neurocysticercosis in the South of Brazil, an investigation was conducted to determine the percentage of suspected cases of neurocysticercosis in computed tomography diagnoses in Santa Maria, RS, from January 1997 to December 1998. Of 6300 computed tomographies (CT of the skull performed at the private Hospital de Caridade Astrogildo de Azevedo, 80, i.e., 1.27% were suspected of neurocysticercosis. Fifty were women (62.5% and 30 were men (37.5%. The most frequent radiological manifestation indicating neurocysticercosis was the presence of calcifications (isolated or associated, with a 95% rate (76 cases, while the presence of hypodense lesions reached a 5% rate (4 cases. After routine analysis, each CT was evaluated again and the suspected cases were confirmed. The percentage of suspected cases of neurocysticercosis detected by CT in the present study carried out in Santa Maria was considered low (1.27%. This can be explained by the fact that tomography is not accessible to the economically underprivileged population of Santa Maria. We hope that the present study can alert the population and the professionals to the fact that neurocysticercosis is a more frequent disease than indicated by the few diagnoses made.Com o objetivo de iniciar um estudo sobre a neurocisticercose no Sul do Brasil, foi verificada a porcentagem de casos suspeitos de neurocisticercose em tomografia computadorizada de crânio (TCC em Santa Maria, entre janeiro de 1997 e dezembro de 1998. Os resultados mostraram que entre 6300 TCC realizadas no Hospital de Caridade Astrogildo de Azevedo, 80, isto é, 1,27% eram suspeitas de neurocisticercose. Constatamos que 50 eram mulheres (62,5% e 30 homens (37,5%. A manifestação radiológica mais freqüente para indicar neurocisticercose foi a calcificação (isolada ou associada com 95% (76 casos, enquanto a presença de lesões hipodensas foi de 5% (4 casos. Após a análise de rotina cada TCC foi

  15. Análise quantitativa do tratamento da escoliose idiopática com o método klapp por meio da biofotogrametria computadorizada Quantitative photogrammetric analysis of the klapp method for treating idiopathic scoliosis

    Directory of Open Access Journals (Sweden)

    Denise H. Iunes

    2010-04-01

    Full Text Available INTRODUÇÃO: Poucos trabalhos comprovam a eficácia das técnicas fisioterapêuticas para o tratamento da escoliose. OBJETIVO: Analisar a eficácia do Método Klapp no tratamento das escolioses por meio do estudo quantitativo pela biofotogrametria computadorizada. MÉTODOS: Dezesseis indivíduos com média de idade de 15±2,61 anos, portadores de escoliose idiopática, foram tratados com o método Klapp. Para análise dos resultados do tratamento, todos foram fotografados antes e após o tratamento, seguindo uma padronização fotográfica. Todas as fotografias foram analisadas quantitativamente por um mesmo experimentador, utilizando o software ALCimagem 2000. A análise estatística foi realizada, utilizando-se a o teste-t pareado com nível de significância de 5%. RESULTADOS: Os resultados apontam para a melhora após o tratamento dos ângulos agromioclaviculares (AC-p=0,00 e esternoclavicular (EC-p=0,01, que avaliam a simetria dos ombros, e para o ângulo que avalia o triângulo de Tales esquerdo, (ΔTe-p=0,02. Em termos de flexibilidade, houve melhora dos ângulos tibiotársicos (ATT-p=0,01 e coxofemoral (CF-p=0,00. Não houve modificações das curvaturas vertebrais e nem melhora no posicionamento da cabeça, apenas na curvatura lombar, avaliada pelo ângulo lordose lombar (LL-p=0,00, sofreu modificação com o tratamento. CONCLUSÃO: O método Klapp foi uma técnica terapêutica eficaz para tratar as assimetrias de tronco e a flexibilidade. Não foi eficaz para assimetrias da pelve, modificações da posição da cabeça, da lordose cervical e cifose torácica.INTRODUCTION: Few studies have proved that physical therapy techniques are efficient in the treatment of scoliosis. OBJECTIVE: To analyze the efficiency of the Klapp method for the treatment of scoliosis, through a quantitative analysis using computerized biophotogrammetry. METHODS: Sixteen participants of a mean age of 15±2.61 yrs. with idiopathic scoliosis were treated using

  16. Assessment of engineered surfaces roughness by high-resolution 3D SEM photogrammetry

    Energy Technology Data Exchange (ETDEWEB)

    Gontard, L.C., E-mail: lionelcg@gmail.com [Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Inorgánica, Universidad de Cádiz, Puerto Real 11510 (Spain); López-Castro, J.D.; González-Rovira, L. [Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Inorgánica, Escuela Superior de Ingeniería, Laboratorio de Corrosión, Universidad de Cádiz, Puerto Real 11519 (Spain); Vázquez-Martínez, J.M. [Departamento de Ingeniería Mecánica y Diseño Industrial, Escuela Superior de Ingeniería, Universidad de Cádiz, Puerto Real 11519 (Spain); Varela-Feria, F.M. [Servicio de Microscopía Centro de Investigación, Tecnología e Innovación (CITIUS), Universidad de Sevilla, Av. Reina Mercedes 4b, 41012 Sevilla (Spain); Marcos, M. [Departamento de Ingeniería Mecánica y Diseño Industrial, Escuela Superior de Ingeniería, Universidad de Cádiz, Puerto Real 11519 (Spain); and others

    2017-06-15

    Highlights: • We describe a method to acquire a high-angle tilt series of SEM images that is symmetrical respect to the zero tilt of the sample stage. The method can be applied in any SEM microscope. • Using the method, high-resolution 3D SEM photogrammetry can be applied on planar surfaces. • 3D models of three surfaces patterned with grooves are reconstructed with high resolution using multi-view freeware photogrammetry software as described in LC Gontard et al. Ultramicroscopy, 2016. • From the 3D models roughness parameters are measured • 3D SEM high-resolution photogrammetry is compared with two conventional methods used for roughness characetrization: stereophotogrammetry and contact profilometry. • It provides three-dimensional information with high-resolution that is out of reach for any other metrological technique. - Abstract: We describe a methodology to obtain three-dimensional models of engineered surfaces using scanning electron microscopy and multi-view photogrammetry (3DSEM). For the reconstruction of the 3D models of the surfaces we used freeware available in the cloud. The method was applied to study the surface roughness of metallic samples patterned with parallel grooves by means of laser. The results are compared with measurements obtained using stylus profilometry (PR) and SEM stereo-photogrammetry (SP). The application of 3DSEM is more time demanding than PR or SP, but it provides a more accurate representation of the surfaces. The results obtained with the three techniques are compared by investigating the influence of sampling step on roughness parameters.

  17. AxiSEM3D: broadband seismic wavefields in 3-D aspherical Earth models

    Science.gov (United States)

    Leng, K.; Nissen-Meyer, T.; Zad, K. H.; van Driel, M.; Al-Attar, D.

    2017-12-01

    Seismology is the primary tool for data-informed inference of Earth structure and dynamics. Simulating seismic wave propagation at a global scale is fundamental to seismology, but remains as one of most challenging problems in scientific computing, because of both the multiscale nature of Earth's interior and the observable frequency band of seismic data. We present a novel numerical method to simulate global seismic wave propagation in realistic 3-D Earth models. Our method, named AxiSEM3D, is a hybrid of spectral element method and pseudospectral method. It reduces the azimuthal dimension of wavefields by means of a global Fourier series parameterization, of which the number of terms can be locally adapted to the inherent azimuthal smoothness of the wavefields. AxiSEM3D allows not only for material heterogeneities, such as velocity, density, anisotropy and attenuation, but also for finite undulations on radial discontinuities, both solid-solid and solid-fluid, and thereby a variety of aspherical Earth features such as ellipticity, topography, variable crustal thickness, and core-mantle boundary topography. Such interface undulations are equivalently interpreted as material perturbations of the contiguous media, based on the "particle relabelling transformation". Efficiency comparisons show that AxiSEM3D can be 1 to 3 orders of magnitude faster than conventional 3-D methods, with the speedup increasing with simulation frequency and decreasing with model complexity, but for all realistic structures the speedup remains at least one order of magnitude. The observable frequency range of global seismic data (up to 1 Hz) has been covered for wavefield modelling upon a 3-D Earth model with reasonable computing resources. We show an application of surface wave modelling within a state-of-the-art global crustal model (Crust1.0), with the synthetics compared to real data. The high-performance C++ code is released at github.com/AxiSEM3D/AxiSEM3D.

  18. High resolution SEM imaging of gold nanoparticles in cells and tissues.

    Science.gov (United States)

    Goldstein, A; Soroka, Y; Frušić-Zlotkin, M; Popov, I; Kohen, R

    2014-12-01

    The growing demand of gold nanoparticles in medical applications increases the need for simple and efficient characterization methods of the interaction between the nanoparticles and biological systems. Due to its nanometre resolution, modern scanning electron microscopy (SEM) offers straightforward visualization of metallic nanoparticles down to a few nanometre size, almost without any special preparation step. However, visualization of biological materials in SEM requires complicated preparation procedure, which is typically finished by metal coating needed to decrease charging artefacts and quick radiation damage of biomaterials in the course of SEM imaging. The finest conductive metal coating available is usually composed of a few nanometre size clusters, which are almost identical to the metal nanoparticles employed in medical applications. Therefore, SEM monitoring of metal nanoparticles within cells and tissues is incompatible with the conventional preparation methods. In this work, we show that charging artefacts related to non-conductive biological specimen can be successfully eliminated by placing the uncoated biological sample on a conductive substrate. By growing the cells on glass pre-coated with a chromium layer, we were able to observe the uptake of 10 nm gold nanoparticles inside uncoated and unstained macrophages and keratinocytes cells. Imaging in back scattered electrons allowed observation of gold nanoparticles located inside the cells, while imaging in secondary electron gave information on gold nanoparticles located on the surface of the cells. By mounting a skin cross-section on an improved conductive holder, consisting of a silicon substrate coated with copper, we were able to observe penetration of gold nanoparticles of only 5 nm size through the skin barrier in an uncoated skin tissue. The described method offers a convenient modification in preparation procedure for biological samples to be analyzed in SEM. The method provides high

  19. Evaluation of bone formation in calcium phosphate scaffolds with μCT-method validation using SEM.

    Science.gov (United States)

    Lewin, S; Barba, A; Persson, C; Franch, J; Ginebra, M-P; Öhman-Mägi, C

    2017-10-05

    There is a plethora of calcium phosphate (CaP) scaffolds used as synthetic substitutes to bone grafts. The scaffold performance is often evaluated from the quantity of bone formed within or in direct contact with the scaffold. Micro-computed tomography (μCT) allows three-dimensional evaluation of bone formation inside scaffolds. However, the almost identical x-ray attenuation of CaP and bone obtrude the separation of these phases in μCT images. Commonly, segmentation of bone in μCT images is based on gray scale intensity, with manually determined global thresholds. However, image analysis methods, and methods for manual thresholding in particular, lack standardization and may consequently suffer from subjectivity. The aim of the present study was to provide a methodological framework for addressing these issues. Bone formation in two types of CaP scaffold architectures (foamed and robocast), obtained from a larger animal study (a 12 week canine animal model) was evaluated by μCT. In addition, cross-sectional scanning electron microscopy (SEM) images were acquired as references to determine thresholds and to validate the result. μCT datasets were registered to the corresponding SEM reference. Global thresholds were then determined by quantitatively correlating the different area fractions in the μCT image, towards the area fractions in the corresponding SEM image. For comparison, area fractions were also quantified using global thresholds determined manually by two different approaches. In the validation the manually determined thresholds resulted in large average errors in area fraction (up to 17%), whereas for the evaluation using SEM references, the errors were estimated to be less than 3%. Furthermore, it was found that basing the thresholds on one single SEM reference gave lower errors than determining them manually. This study provides an objective, robust and less error prone method to determine global thresholds for the evaluation of bone formation in

  20. Influence of the interplay between helicoidal magnetic ordering and ...

    Indian Academy of Sciences (India)

    ordering and superconductivity on the differential conductance in ... carbide compounds are motivated by the possibility of a detailed investigation of the anisotropy of .... The last equation corresponds to the usual BCS self-consistent ... the actual electron–phonon interaction λ and its effective value, we can expand quanti-.

  1. Macromolecular 3D SEM reconstruction strategies: Signal to noise ratio and resolution

    International Nuclear Information System (INIS)

    Woodward, J.D.; Wepf, R.A.

    2014-01-01

    Three-dimensional scanning electron microscopy generates quantitative volumetric structural data from SEM images of macromolecules. This technique provides a quick and easy way to define the quaternary structure and handedness of protein complexes. Here, we apply a variety of preparation and imaging methods to filamentous actin in order to explore the relationship between resolution, signal-to-noise ratio, structural preservation and dataset size. This information can be used to define successful imaging strategies for different applications. - Highlights: • F-actin SEM datasets were collected using 8 different preparation/ imaging techniques. • Datasets were reconstructed by back projection and compared/analyzed • 3DSEM actin reconstructions can be produced with <100 views of the asymmetric unit. • Negatively stained macromolecules can be reconstructed by 3DSEM to ∼3 nm resolution

  2. The application of SEM in analyzing the damage to the petroleum reservoirs caused by drilling fluids

    International Nuclear Information System (INIS)

    Abdul Razak Ismail

    1996-01-01

    An experimental study has been conducted to analyze the damage to the potential oil and gas reservoirs due to the invasion of drilling fluid during drilling operation. Two types of rock samples representing low and high permeability were used to stimulate the petroleum reservoirs. Sea water based drilling fluids were used in this study. Detail observations to the rock samples were analyzed using scanning electron microscope (SEM). The results of both permeability restoration and SEM observation showed that severe permeability impairments were obtained for high permeability rock. These results indicate that the relative size of the barite particles and the pore size distribution and characteristics of the formation play an important role in determining the damage caused by the drilling fluids

  3. Inconmensurabilidad semántica y progreso científico

    Directory of Open Access Journals (Sweden)

    Vázquez, Juan

    1997-08-01

    Full Text Available Not available.En la primera parte del trabajo se hace una presentación de las nociones de «inconmensurabilidad», tal como han sido formuladas por Feyerabend y Kuhn; y en la segunda parte, después de analizar los presupuestos semánticos con los que indudablemente han ido asociadas, se presenta un modelo alternativo de análisis semántico de la ‘inconmensurabilidad’, que permite desligarla de las nociones de «incomunicabilidad» e «incomparabilidad» interteóricas. Con ese propósito se hace uso de una doble noción de objeto formulada por C. S. Peirce, en sus Collected Papers, y por E. Husserl, en el parágrafo 131 de las Ideas.

  4. OpenCV-Based Nanomanipulation Information Extraction and the Probe Operation in SEM

    Directory of Open Access Journals (Sweden)

    Dongjie Li

    2015-02-01

    Full Text Available Aimed at the established telenanomanipulation system, the method of extracting location information and the strategies of probe operation were studied in this paper. First, the machine learning algorithm of OpenCV was used to extract location information from SEM images. Thus nanowires and probe in SEM images can be automatically tracked and the region of interest (ROI can be marked quickly. Then the location of nanowire and probe can be extracted from the ROI. To study the probe operation strategy, the Van der Waals force between probe and a nanowire was computed; thus relevant operating parameters can be obtained. With these operating parameters, the nanowire in 3D virtual environment can be preoperated and an optimal path of the probe can be obtained. The actual probe runs automatically under the telenanomanipulation system's control. Finally, experiments were carried out to verify the above methods, and results show the designed methods have achieved the expected effect.

  5. Consideraciones sobre la adquisición del adjetivo y su semántica

    OpenAIRE

    Millán Garrido, Mª del Rosario

    1988-01-01

    Con este trabajo se intenta profundizar en el adjetivo con un criterio semántico pero al ser difícil deslindarlo de sus estudios léxico y sintáctico, no vamos a excluir de él estos aspectos que se expondrán de forma breve y que nos ayudarán a sacar conclusiones más completas. Aunque la semántica ha ocupado la parte central de la investigación, ha tenido como apoyo el análisis léxico, reflejado en las gráficas, y un estudio sintáctico** previo.

  6. Minería de opiniones basada en patrones semánticos en Twitter

    OpenAIRE

    Artacho Torres, Pablo

    2014-01-01

    La minería de opinión o análisis de sentimiento es un tipo de análisis de texto que pretende ayudar a la toma de decisiones a través de la extracción y el análisis de opiniones, identificando las opiniones positivas, negativas y neutras; y midiendo su repercusión en la percepción de un tópico. En este trabajo se propone un modelo de análisis de sentimiento basado en diccionarios, que a través de la semántica y de los patrones semánticos que conforman el texto a clasificar, permite obtener la ...

  7. Morphology of Poly lactide/Polycaprolactone (PLA/PCL) Nano composite by Scanning Electron Microscopy (SEM)

    International Nuclear Information System (INIS)

    Siti Zulaiha Hairaldin; Wan Md Zin Wan Yunus; Norazowa Ibrahim

    2011-01-01

    In this study, Octadecylamine Modified Montmorillonites (ODAMMT) were used to prepare Poly lactide/ Polycaprolactone (PLA/ PCL) nano composites. PLA and PCL mix in 90:10 ratios, using an internal mixer by melt blending technique. The other sample was blend with Natrium Montmorillonite (NaMMT) and Octadecylamine Modified Montmorillonite (ODA-MMT) to produce PLA/ PCL-NaMMT and PLA/ PCL ODAMMT. To characterize the polymer nano composites, X-ray diffraction (XRD), FTIR and SEM analysis were conducted. Comparison of morphology were made up between PLA/ PCL, PLA/ PCL with presence of 7 % of Na-MMT and 7 % ODA-MMT respectively based on SEM micrograph by calculate the number-average diameter. (author)

  8. Optimization study of direct morphology observation by cold field emission SEM without gold coating.

    Science.gov (United States)

    He, Dan; Fu, Cheng; Xue, Zhigang

    2018-06-01

    Gold coating is a general operation that is generally applied on non-conductive or low conductive materials, during which the morphology of the materials can be examined by scanning electron microscopy (SEM). However, fatal deficiencies in the materials can result in irreversible distortion and damage. The present study directly characterized different low conductive materials such as hydroxyapatite, modified poly(vinylidene fluoride) (PVDF) fiber, and zinc oxide nanopillar by cold field emission scanning electron microscopy (FE-SEM) without a gold coating. According to the characteristics of the low conductive materials, various test conditions, such as different working signal modes, accelerating voltages, electron beam spots, and working distances, were characterized to determine the best morphological observations of each sample. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Cryo-FIB SEM for Characterization of the Structure of Fish Oil Emulsions

    DEFF Research Database (Denmark)

    Jensen, Louise Helene Søgaard; Horn, Anna Frisenfeldt; Jacobsen, Charlotte

    2011-01-01

    layers. The emulsion fractures are random and impossible to control when using freeze-fracture cryo-SEM. We have previously shown that some types of emulsifiers tend to break along the interface layer, while others cause the fractures to be perpendicular to the interface layer [3]. To control the field...... of view more specifically and to ensure the access to the desired part of the sample, we propose now the use of cryo-FIB SEM. This method allows us to access the interface layers as needed, see figure 1. Emulsions with high oil content, i.e. 70%, and relatively large oil droplets, i.e. μm range, have been...

  10. A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis

    Science.gov (United States)

    Lane, John

    2009-01-01

    A simple 2D M N matrix involving sample preparation enables the microanalyst to peer below the noise floor of element percentages reported by the SEM/EDX (scanning electron microscopy/ energy dispersive x-ray) analysis, thus yielding more meaningful data. Using the example of a 2 3 sample set, there are M = 2 concentration levels of the original mix under test: 10 percent ilmenite (90 percent silica) and 20 percent ilmenite (80 percent silica). For each of these M samples, N = 3 separate SEM/EDX samples were drawn. In this test, ilmenite is the element of interest. By plotting the linear trend of the M sample s known concentration versus the average of the N samples, a much higher resolution of elemental analysis can be performed. The resulting trend also shows how the noise is affecting the data, and at what point (of smaller concentrations) is it impractical to try to extract any further useful data.

  11. Contrast of Backscattered Electron SEM Images of Nanoparticles on Substrates with Complex Structure

    Directory of Open Access Journals (Sweden)

    Thomas Kowoll

    2017-01-01

    Full Text Available This study is concerned with backscattered electron scanning electron microscopy (BSE SEM contrast of complex nanoscaled samples which consist of SiO2 nanoparticles (NPs deposited on indium-tin-oxide covered bulk SiO2 and glassy carbon substrates. BSE SEM contrast of NPs is studied as function of the primary electron energy and working distance. Contrast inversions are observed which prevent intuitive interpretation of NP contrast in terms of material contrast. Experimental data is quantitatively compared with Monte-Carlo- (MC- simulations. Quantitative agreement between experimental data and MC-simulations is obtained if the transmission characteristics of the annular semiconductor detector are taken into account. MC-simulations facilitate the understanding of NP contrast inversions and are helpful to derive conditions for optimum material and topography contrast.

  12. Contrast of Backscattered Electron SEM Images of Nanoparticles on Substrates with Complex Structure.

    Science.gov (United States)

    Kowoll, Thomas; Müller, Erich; Fritsch-Decker, Susanne; Hettler, Simon; Störmer, Heike; Weiss, Carsten; Gerthsen, Dagmar

    2017-01-01

    This study is concerned with backscattered electron scanning electron microscopy (BSE SEM) contrast of complex nanoscaled samples which consist of SiO 2 nanoparticles (NPs) deposited on indium-tin-oxide covered bulk SiO 2 and glassy carbon substrates. BSE SEM contrast of NPs is studied as function of the primary electron energy and working distance. Contrast inversions are observed which prevent intuitive interpretation of NP contrast in terms of material contrast. Experimental data is quantitatively compared with Monte-Carlo- (MC-) simulations. Quantitative agreement between experimental data and MC-simulations is obtained if the transmission characteristics of the annular semiconductor detector are taken into account. MC-simulations facilitate the understanding of NP contrast inversions and are helpful to derive conditions for optimum material and topography contrast.

  13. Characterising palladium-silver and palladium-nickel alloy membranes using SEM, XRD and PIXE

    International Nuclear Information System (INIS)

    Keuler, J.N.; Lorenzen, L.; Sanderson, R.D.; Prozesky, V.; Przybylowicz, W.J.

    1999-01-01

    Palladium alloy membranes were prepared by successive electroless plating steps on an alumina-zirconia support membrane. Palladium, silver and nickel were deposited in layers and then the metal films were heat treated for 5 h in a hydrogen atmosphere at 650 deg. C. The topography of the metal coatings and cross-sections of the films (before and after heating) were characterised using scanning electron microscopy (SEM). XRD was used to determine the crystal phase of the alloy coatings. Both SEM and XRD provide only surface information and therefore micro-PIXE was used to extract depth information of the alloy coating. Concentration profiles across the thickness of the films were constructed to determine penetration of the coating into the support membrane pores during electroless plating and to investigate diffusion of coated layers during the heating step

  14. Electronic structure and optical properties of (BeTen/(ZnSem superlattices

    Directory of Open Access Journals (Sweden)

    Caid M.

    2016-03-01

    Full Text Available The structural, electronic and optical properties of (BeTen/(ZnSem superlattices have been computationally evaluated for different configurations with m = n and m≠n using the full-potential linear muffin-tin method. The exchange and correlation potentials are treated by the local density approximation (LDA. The ground state properties of (BeTen/(ZnSem binary compounds are determined and compared with the available data. It is found that the superlattice band gaps vary depending on the layers used. The optical constants, including the dielectric function ε(ω, the refractive index n(ω and the refractivity R(ω, are calculated for radiation energies up to 35 eV.

  15. Local behavior of an AISI 304 stainless steel submitted to in situ biaxial loading in SEM

    Energy Technology Data Exchange (ETDEWEB)

    Caër, C., E-mail: celia.caer@gmail.com; Pesci, R.

    2017-04-06

    The microstructural response of a coarse grained AISI 304 stainless steel submitted to biaxial tensile loading was investigated using SEM and X-ray diffraction. The specimen geometry was designed to allow for biaxial stress state and incipient crack in the center of the active part under biaxial tensile loading. This complex loading was performed step by step by a micromachine fitting into a SEM chamber. At each loading step FSD pictures and EBSD measurements were carried out to study the microstructural evolution of the alloy, namely grain rotations and misorientations, stress-induced martensite formation and crack propagation. According to their initial orientation, grains are found to behave differently under loading. Approximately 60% of grains are shown to reorient to the [110] Z orientation under biaxial tensile loading, whereas the 40% left undergo high plastic deformation. EBSD and XRD measurements respectively performed under loading and on the post mortem specimen highlighted the formation of about 4% of martensite.

  16. XRD and SEM analysis of hydroxyapatite during immersion in stimulated physiological solutions

    International Nuclear Information System (INIS)

    Yusof Abdullah; Idris Besar; Rosmamuhamadani Ramli; Abd Razak Daud

    2000-01-01

    XRD and SEM techniques were used to analyse the apatite layer developed on the synthetic hydroxyapatite surface following immersion in the simulated body fluid (SBF) that mimics the conditions of material experiences after implantation in the human body. Initially, the new layers formed after 7 day's incubation and increased with immersion time as crystallization of apatite phase. The XRD confirmed that the deposited layer was hydroxyapatite and crystallographically. With time, the crystal growth become more random and the intensity of the peaks decreased. During immersion, hydroxyapatite was precipitated from the SBF and coherently scattered with very small crystal. The SEM observation shows that the new precipitates were increased as well as incubation period increased. Therefore, hydroxyapatite ceramics are suggested to have very good biocompatibility. (Author)

  17. Uncertainty in the use of MAMA software to measure particle morphological parameters from SEM images

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Daniel S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tandon, Lav [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-05

    The MAMA software package developed at LANL is designed to make morphological measurements on a wide variety of digital images of objects. At LANL, we have focused on using MAMA to measure scanning electron microscope (SEM) images of particles, as this is a critical part of our forensic analysis of interdicted radiologic materials. In order to successfully use MAMA to make such measurements, we must understand the level of uncertainty involved in the process, so that we can rigorously support our quantitative conclusions.

  18. Dynamic Correction of Higher-Order Deflection Aberrations in the Environmental SEM

    Czech Academy of Sciences Publication Activity Database

    Oral, Martin; Neděla, Vilém

    2015-01-01

    Roč. 21, S4 (2015), s. 194-199 ISSN 1431-9276 R&D Projects: GA ČR(CZ) GA14-22777S; GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : environmental SEM * ESEM * shifted deflection pivot point * Higher order deflection aberrations * vignetting * dynamic focusing * dynamic stigmator * dynamic correction Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.730, year: 2015

  19. SEM-analysis of grain boundary porosity in three S-176 specimens

    International Nuclear Information System (INIS)

    Malen, K.; Birath, S.; Mattsson, O.

    1980-10-01

    Porosity in UO 2 -fuel has been studied in scanning electron microscope (SEM). The aim was to obtain a basis for evaluation of porosity in high burnup power reactor fuel. Three specimens have been analyzed. In the high temperature zones porosity can be seen both on grain boundaries and at grain edges. In the low temperature regions very little changes seem to have occurred during irradiation. (author)

  20. SEM/TIMS analysis trials on hotswipe samples taken from a shielded cell at Harwell

    International Nuclear Information System (INIS)

    Tushingham, J.; Vatter, I.; Cooke, R.

    1998-09-01

    The IAEA require advanced techniques and procedures for the detection of traces of actinides to be applied to their environmental sampling programme for nuclear safeguards as a means to detect undeclared activities. 'Swipe' samples taken from within nuclear facilities by IAEA inspectors require analysis to determine their actinide content and composition by bulk and particle measurements. The use of analytical equipment capable of analysing individual particles, particularly of actinides, is essential to optimise the IAEA's aim to monitor Member State's nuclear activities more proficiently. A trial has been undertaken at the Harwell Laboratory of AEA Technology to establish the efficacy of scanning electron microscopy (SEM) and thermal ionisation mass spectrometry (TIMS) for the particle and bulk characterisation, respectively, of actinides on samples taken from within a shielded cell. These measurements were supported by γ-spectrometry and α-spectrometry. 'Hotswipe' samples taken from within a shielded cell with a well-known recent history have been prepared for particle and bulk analysis. SEM has been used to characterise individual particles from the swipe samples and the results have been related to known cell activities. Samples were prepared for SEM using a simple procedure to minimise the potential for sample contamination. The method proved to be capable of identifying 1 μm particles that contained U, Pu, Pa and Np. The measurement of U/Pu ratios was limited to particles that contained >2% Pu in U by weight. TIMS, together with alpha spectrometry, has been used to determine the bulk actinide composition of the samples whilst gamma spectrometry has been used to determine the fission product composition. Further work to improve the potential of SEM, and also secondary ionisation mass spectrometry (SIMS), for the measurement of hotswipe samples has been proposed. (author)

  1. Does your SEM really tell the truth? How would you know? part 3: vibration and drift

    Science.gov (United States)

    Postek, Michael T.; Vladár, András. E.; Cizmar, Petr

    2014-09-01

    This is the third of a series of papers discussing various causes of measurement uncertainty in scanned particle beam instruments, and some of the solutions researched and developed at NIST. Scanned particle beam instruments especially the scanning electron microscope (SEM) have gone through tremendous evolution to become indispensable tools for many and diverse scientifi c and industrial applications. These improvements have signifi cantly enhanced their performance and made them far easier to operate. But, ease of operation has also fostered operator complacency. In addition, the user-friendliness has reduced the need for extensive operator training. Unfortunately, this has led to the concept that the SEM is just another expensive digital camera or another peripheral device connected to a computer and that all of the issues related to obtaining quality data have been solved. Hence, a person (or company) using these instruments may be lulled into thinking that all of the potential pitfalls have been fully eliminated and they believe everything they see on the micrograph is always correct. But, as described in this and the earlier presentations this may not be the case. The fi rst paper in this series discussed some of the issues related to signal generation in the SEM, including instrument calibration, electron beam-sample interactions and the need for physics-based modelling to understand the actual image formation mechanisms to properly interpret SEM images. The second paper, discussed another major issue confronting the microscopist: specimen contamination and methods of contamination elimination. This third paper, discusses vibration and drift and some useful solutions.

  2. Nanomanufacturing concerns about measurements made in the SEM Part III: vibration and drift

    Science.gov (United States)

    Postek, Michael T.; Vladár, András. E.; Cizmar, Petr

    2014-08-01

    Many advanced manufacturing processes employ scanning electron microscopes (SEM) for on-line critical measurements for process and quality control. This is the third of a series of papers discussing various causes of measurement uncertainty in scanned particle beam instruments, and some of the solutions researched and developed at NIST. Scanned particle beam instruments especially the scanning electron microscope have gone through tremendous evolution to become indispensable tools for many and diverse scientifi c and industrial applications. These improvements have signifi cantly enhanced their performance and made them far easier to operate. But, ease of operation has also fostered operator complacency. In addition, the user-friendliness has reduced the need for extensive operator training. Unfortunately, this has led to the concept that the SEM is just another expensive digital camera or another peripheral device connected to a computer and that all of the issues related to obtaining quality data have been solved. Hence, a person (or company) using these instruments may be lulled into thinking that all of the potential pitfalls have been fully eliminated and they believe everything they see on the micrograph is always correct. But, as described in this and the earlier presentations this may not be the case. The fi rst paper in this series discussed some of the issues related to signal generation in the SEM, including instrument calibration, electron beam-sample interactions and the need for physics-based modelling to understand the actual image formation mechanisms to properly interpret SEM images. The second paper, discussed another major issue confronting the microscopist: specimen contamination and methods of contamination elimination. This third paper, discusses vibration and drift and some useful solutions.

  3. Methods for Additive Hydration Allowing Observation of Fully Hydrated State of Wet Samples in Environmental SEM

    Czech Academy of Sciences Publication Activity Database

    Neděla, Vilém

    2007-01-01

    Roč. 70, č. 2 (2007), s. 95-100 ISSN 1059-910X R&D Projects: GA ČR(CZ) GA102/05/0886; GA AV ČR KJB200650602 Institutional research plan: CEZ:AV0Z20650511 Keywords : agar * natural structure * biological specimens * environmental SEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.644, year: 2007

  4. A new method using Scanning Electron Microscopy (SEM) for preparation of anisopterous odonates.

    Science.gov (United States)

    Del Palacio, Alejandro; Sarmiento, Patricia Laura; Javier, Muzón

    2017-10-01

    Anisopterous odonate male's secondary genitalia is a complex of several structures, among them the vesica spermalis is the most informative with important specific characters. The observation of those characters, mostly of membranous nature, is difficult in the Scanning Electron Microscope due to dehydration and metallization processes. In this contribution, we discuss a new and low cost procedure for the observation of these characters in the SEM, compatible with the most common agents used for preserving specimens. © 2017 Wiley Periodicals, Inc.

  5. GammaSem Proceedings. A Nordic seminar for users of gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Straalberg, E. (ed.) (Institute for Energy Technolgy (Norway)); Berg, K. (National Institute of Radiation Protection (Denmark)); Dowdall, M. (Norwegian Radiation Protection Authority (Norway)) (and others)

    2010-11-15

    The project GammaSem was proposed to the NKS in 2008. The aim of the project was to arrange two seminars for users of gamma spectrometry, in 2009 and 2010. The seminars were meant to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and initiate a network of gamma spectrometry users in the Nordic countries. Such a Nordic network should strengthen the collaboration between laboratories and improve all participants' competence in practical gamma spectrometry. Both seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 65 people signed up for GammaSem 2010; representing 30 different universities, commercial companies, research institutes and authorities. The working group concept as presented at last year's GammaSem, has not worked out as intended. The reason for this is probably because most of the laboratories that signed up to join the working groups, signed up because they wanted to learn more about the different subjects. In combination with the fact that no funding was made available for the working groups, it was difficult to establish goals on what to achieve. None of the working groups applied for funding from the NKS (or elsewhere) to establish separate projects. There is a big need for more cooperation and for training within the field of gamma spectrometry. This fact has been proved through these two seminars, both by the many different topics that have been discussed, but also by the huge interest for participating in the suggested series of workshop. The GammaSem seminars have thus provided a much welcomed starting point for a broader Nordic collaboration. (Author)

  6. Quantitative Analysis of Micro-porosity of Eco-material by Using SEM Technique

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ji-ru; LIU Yuan-zhi; LIU Zu-de

    2004-01-01

    Microstructure of the eco-material combining vegetation recovery with slope protection is important for determining plant-growing properties.Several techniques for analyzing the eco-material microstructure are presented,including the freeze-cut-drying method of preparing samples for scanning electronic microscopy (SEM),the SEM image processing technique and quantifying analysis method of the SEM images,and etc.The aggregates and pores in SEM images are identified using the different mathematics operators,and their effects are compared.The areas of aggregates and pores are obtained using the operator of morphology,and the influences of different thresholds in image segmentation are also discussed.The results show that the method,in which the variation of non-maximum grey-level gradient is limited,improves the effect of edge detections due to a weak distinction existing at the edge between the aggregates and pores in image.The determination of the threshold should combine the image characteristic with filling operation,so as to assure the precision of the image analysis,in which the contact-segmentation is the simplest and most effective method.The results also show that the pore areas in eco-materials are generally larger than those in the correlative soils,and their increment is large as soil fabric being fine.These differences are related to admixture of expansive perliticThe operator of morphology provides a new method for the image analysis of other porous material microstructure such as soils and concretes.

  7. Do generic strategies impact performance in higher educational institutions? A SEM-based investigation

    OpenAIRE

    Ahlam Mohammad Alzoubi; Okechukwu Lawrence Emeagwali

    2016-01-01

    This study set out to initiate an investigation into the linkage between generic strategy and performance in higher educational institutions and the moderating effect of institution-type. Using structural equation modeling (SEM), it examined the responses of a stratified sample of academics and administrative staff (n= 333) randomly selected from eight universities in northern Cyprus. Findings suggest that while there is a weak effect of differentiation strategy on performance, a strong effec...

  8. Ontologías y Web Semántica 2005. Resumen del taller

    OpenAIRE

    Corcho, Oscar; Gómez-Pérez, A.; Fernández López, Mariano; Ramos Gargantilla, JA.

    2006-01-01

    En este artículo se resumen los resultados obtenidos en el taller “Ontologías y Web Semántica 2005”, que fue celebrado el día 14 de noviembre de 2005 en Santiago de Compostela, en el contexto de la Conferencia de la Asociación Española para la Inteligencia Artificial (CAEPIA2005).

  9. Módulos interactivos para el aprendizaje de la semántica.

    OpenAIRE

    Aquino Palacios, Ingrid

    2012-01-01

    Se proponen modulos interactivos para lograr el aprendizaje de la semantica en alumnos del V semestre de la Carrera de Lenguas, Literatura y Comunicacion de la Facultad de Educacion de la UNCP. Los metodos utilizados fueron el experimental y el bibliografico-documental. Los instrumentos utilizados fueron la prueba objetiva, prueba de ensayo y la prueba pedagogica. Se logró mejorar el aprendizaje de la semántica 

  10. Quantifying Golgi structure using EM: combining volume-SEM and stereology for higher throughput.

    Science.gov (United States)

    Ferguson, Sophie; Steyer, Anna M; Mayhew, Terry M; Schwab, Yannick; Lucocq, John Milton

    2017-06-01

    Investigating organelles such as the Golgi complex depends increasingly on high-throughput quantitative morphological analyses from multiple experimental or genetic conditions. Light microscopy (LM) has been an effective tool for screening but fails to reveal fine details of Golgi structures such as vesicles, tubules and cisternae. Electron microscopy (EM) has sufficient resolution but traditional transmission EM (TEM) methods are slow and inefficient. Newer volume scanning EM (volume-SEM) methods now have the potential to speed up 3D analysis by automated sectioning and imaging. However, they produce large arrays of sections and/or images, which require labour-intensive 3D reconstruction for quantitation on limited cell numbers. Here, we show that the information storage, digital waste and workload involved in using volume-SEM can be reduced substantially using sampling-based stereology. Using the Golgi as an example, we describe how Golgi populations can be sensed quantitatively using single random slices and how accurate quantitative structural data on Golgi organelles of individual cells can be obtained using only 5-10 sections/images taken from a volume-SEM series (thereby sensing population parameters and cell-cell variability). The approach will be useful in techniques such as correlative LM and EM (CLEM) where small samples of cells are treated and where there may be variable responses. For Golgi study, we outline a series of stereological estimators that are suited to these analyses and suggest workflows, which have the potential to enhance the speed and relevance of data acquisition in volume-SEM.

  11. Nanomanufacturing Concerns about Measurements Made in the SEM Part IV: Charging and its Mitigation.

    Science.gov (United States)

    Postek, Michael T; Vladár, András E

    2015-01-01

    This is the fourth part of a series of tutorial papers discussing various causes of measurement uncertainty in scanned particle beam instruments, and some of the solutions researched and developed at NIST and other research institutions. Scanned particle beam instruments especially the scanning electron microscope (SEM) have gone through tremendous evolution to become indispensable tools for many and diverse scientific and industrial applications. These improvements have significantly enhanced their performance and made them far easier to operate. But, the ease of operation has also fostered operator complacency. In addition, the user-friendliness has reduced the apparent need for extensive operator training. Unfortunately, this has led to the idea that the SEM is just another expensive "digital camera" or another peripheral device connected to a computer and that all of the problems in obtaining good quality images and data have been solved. Hence, one using these instruments may be lulled into thinking that all of the potential pitfalls have been fully eliminated and believing that, everything one sees on the micrograph is always correct. But, as described in this and the earlier papers, this may not be the case. Care must always be taken when reliable quantitative data are being sought. The first paper in this series discussed some of the issues related to signal generation in the SEM, including instrument calibration, electron beam-sample interactions and the need for physics-based modeling to understand the actual image formation mechanisms to properly interpret SEM images. The second paper has discussed another major issue confronting the microscopist: specimen contamination and methods to eliminate it. The third paper discussed mechanical vibration and stage drift and some useful solutions to mitigate the problems caused by them, and here, in this the fourth contribution, the issues related to specimen "charging" and its mitigation are discussed relative to

  12. Elemental analyses of bulk and individual particles by PIXE and SEM-EDX

    International Nuclear Information System (INIS)

    Kasahara, Mikio; Shinoda, Kazuyuki; Takahashi, Kanji; Yoshida, Kouji.

    1993-01-01

    The atmospheric aerosol samples were collected by a stacked filter method under the various environmental conditions. The elemental concentrations of aerosol particles were measured using PIXE analysis as a bulk sample. And also elemental compositions of about 200 individual particles per each sample were measured by SEM-EDX analysis. In this study, the correspondencies of analytical results measured by both analyses as well as chemical characteristics of individual and bulk aerosols were investigated. (author)

  13. SEM visualization of glycosylated surface molecules using lectin-coated microspheres

    Science.gov (United States)

    Duke, J.; Janer, L.; Campbell, M.

    1985-01-01

    There are several techniques currently used to localize glycosylated surface molecules by scanning electron microscopy (Grinnell, 1980; Molday, 1976; Linthicum and Sell, 1975; Nicolson, 1974; Lo Buglio, et al, 1972). A simple and rapid method, using a modification of Grinnell's technique is reported here. Essentially, microspheres coated with Concavalin A are used to bind to glycosylated regions of the palatal shelf epithelium and are visualized in the scanning electron microscope (SEM).

  14. Study of SEM induced current and voltage contrast modes to assess semiconductor reliability

    Science.gov (United States)

    Beall, J. R.

    1976-01-01

    The purpose of the scanning electron microscopy study was to review the failure history of existing integrated circuit technologies to identify predominant failure mechanisms, and to evaluate the feasibility of their detection using SEM application techniques. The study investigated the effects of E-beam irradiation damage and contamination deposition rates; developed the necessary methods for applying the techniques to the detection of latent defects and weaknesses in integrated circuits; and made recommendations for applying the techniques.

  15. GammaSem Proceedings. A Nordic seminar for users of gamma spectrometry

    International Nuclear Information System (INIS)

    Straelberg, E.; Berg, K.; Dowdall, M.

    2010-11-01

    The project GammaSem was proposed to the NKS in 2008. The aim of the project was to arrange two seminars for users of gamma spectrometry, in 2009 and 2010. The seminars were meant to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and initiate a network of gamma spectrometry users in the Nordic countries. Such a Nordic network should strengthen the collaboration between laboratories and improve all participants' competence in practical gamma spectrometry. Both seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 65 people signed up for GammaSem 2010; representing 30 different universities, commercial companies, research institutes and authorities. The working group concept as presented at last year's GammaSem, has not worked out as intended. The reason for this is probably because most of the laboratories that signed up to join the working groups, signed up because they wanted to learn more about the different subjects. In combination with the fact that no funding was made available for the working groups, it was difficult to establish goals on what to achieve. None of the working groups applied for funding from the NKS (or elsewhere) to establish separate projects. There is a big need for more cooperation and for training within the field of gamma spectrometry. This fact has been proved through these two seminars, both by the many different topics that have been discussed, but also by the huge interest for participating in the suggested series of workshop. The GammaSem seminars have thus provided a much welcomed starting point for a broader Nordic collaboration. (Author)

  16. Morphological and Production Changes in Stressed Red Yeasts Monitored Using SEM and Raman Spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Hrubanová, Kamila; Samek, Ota; Haroniková, A.; Bernatová, Silvie; Zemánek, Pavel; Márová, I.; Krzyžánek, Vladislav

    2016-01-01

    Roč. 22, S3 (2016), s. 1146-1147 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA ČR(CZ) GA14-20012S; GA ČR(CZ) GA15-20645S Institutional support: RVO:68081731 Keywords : SEM * Raman spectroscopy Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.891, year: 2016

  17. SemMat: Federated Semantic Services Platform for Open materials Science and Engineering

    Science.gov (United States)

    2017-01-01

    SEMMAT: FEDERATED SEMANTIC SERVICES PLATFORM FOR OPEN MATERIALS SCIENCE AND ENGINEERING WRIGHT STATE UNIVERSITY JANUARY 2017 FINAL TECHNICAL...COVERED (From - To) JUL 2013 – JUN 2016 4. TITLE AND SUBTITLE SemMat: FEDERATED SEMANTIC SERVICES PLATFORM FOR OPEN MATERIALS SCIENCE AND ENGINEERING...models to represent materials data. This provides a data exchange scheme for materials science , which also includes provenance information to promote

  18. 3-D Analysis of Graphite Nodules in Ductile Cast Iron Using FIB-SEM

    DEFF Research Database (Denmark)

    D'Angelo, Luca; Jespersen, Freja N.; MacDonald, A. Nicole

    Ductile cast iron samples were analysed in a Focused Ion Beam Scanning Electron Microscope, FIB-SEM. The focussed ion beam was used to carefully remove layers of the graphite nodules to reveal internal structures in the nodules. The sample preparation and milling procedure for sectioning graphite...... inside the nodules, their orientation in relation to the graphite and the chemistry of the inclusions is analysed and described. Formation of the structures during solidification and subsequent cooling to room temperature is discussed....

  19. Monitoring of Multilayered Bacterial Biofilm Morphology by Cryo-SEM for Raman Spectroscopy Measurements

    Czech Academy of Sciences Publication Activity Database

    Hrubanová, Kamila; Bernatová, Silvie; Samek, Ota; Šerý, Mojmír; Zemánek, Pavel; Nebesářová, Jana; Růžička, F.; Krzyžánek, Vladislav

    2015-01-01

    Roč. 21, S3 (2015), s. 187-188 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01; GA ČR(CZ) GA14-20012S Institutional support: RVO:68081731 ; RVO:60077344 Keywords : multilayered bacterial biofilm * morphology by Cryo-SEM * Raman spectroscopy Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.730, year: 2015

  20. Fuzzy Control and Connected Region Marking Algorithm-Based SEM Nanomanipulation

    Directory of Open Access Journals (Sweden)

    Dongjie Li

    2012-01-01

    Full Text Available The interactive nanomanipulation platform is established based on fuzzy control and connected region marking (CRM algorithm in SEM. The 3D virtual nanomanipulation model is developed to make up the insufficiency of the 2D SEM image information, which provides the operator with depth and real-time visual feedback information to guide the manipulation. The haptic device Omega3 is used as the master to control the 3D motion of the nanopositioner in master-slave mode and offer the force sensing to the operator controlled with fuzzy control algorithm. Aiming at sensing of force feedback during the nanomanipulation, the collision detection method of the virtual nanomanipulation model and the force rending model are studied to realize the force feedback of nanomanipulation. The CRM algorithm is introduced to process the SEM image which provides effective position data of the objects for updating the virtual environment (VE, and relevant issues such as calibration and update rate of VE are also discussed. Finally, the performance of the platform is validated by the ZnO nanowire manipulation experiments.

  1. Application of SEM/EBSD and FEG-TEM/CBED to determine eutectic solidification mechanisms

    International Nuclear Information System (INIS)

    Nogita, K.; Dahle, A.K.; Drennan, J.

    2002-01-01

    Full text: This study shows the application of electron backscatter diffraction (EBSD) in SEM and convergent beam electron diffraction (CBED) in FEG-TEM to determine eutectic nucleation and growth in hypoeutectic Al-Si foundry alloys. Because the eutectic reaction is often the final stage of solidification it can be expected to have a significant impact on the formation of casting defects, particularly porosity. Previous EBSD work by Nogita and Dahle (2001), Dahle et al (2001), has shown that the eutectic nucleates on the primary phase in the unmodified alloy, and eutectic grains are nucleated in the intergranular liquid, instead of filling the dendrite envelopes, when Sr or Sb is added. However, the orientation relationship between silicon and aluminium in the eutectic has so far not been determined because of difficulties with sample preparation for EBSD and also detection limitations of Kikuchi refraction of silicon and aluminium, particularly in modified alloys with a refined eutectic. The combination of the EBSD technique in SEM and CBED in TEM analyses can provide crystallographic orientation relationships between primary aluminium dendrites, eutectic aluminium and silicon, which are important to explicitly define the solidification mode of the eutectic in hypoeutectic Al-Si alloys. These relationships are influenced, and altered, by the addition of certain elements. This paper also describes the sample preparation techniques for SEM and TEM for samples with different eutectic structures. The advantages the techniques are discussed. Copyright (2002) Australian Society for Electron Microscopy Inc

  2. SEM Characterization of an Irradiated Monolithic U-10Mo Fuel Plate

    International Nuclear Information System (INIS)

    Keiser, D.D. Jr.; Jue, J.F.; Robinson, A.B.

    2010-01-01

    Results of scanning electron microscopy (SEM) characterization of irradiated U-7Mo dispersion fuel plates with differing amounts of matrix Si have been reported. However, to date, no results of SEM analysis of irradiated U-Mo monolithic fuel plates have been reported. This paper describes the first SEM characterization results for an irradiated monolithic U-10Mo fuel plate. Two samples from this fuel plate were characterized. One sample was produced from the low-flux side of the fuel plate, and another was produced at the high-flux side of the fuel plate. This characterization focused on the microstructural features present at the U-10Mo foil/cladding interface, particularly the interaction zone that had developed during fabrication and irradiation. In addition, the microstructure of the foil itself was investigated, along with the morphology of the observed fission gas bubbles. It was observed that a Si-rich interaction layer was present at the U-10Mo foil/cladding interface that exhibited relatively good irradiation behavior, and within the U-10Mo foil the microstructural features differed in some respects from what is typically seen in the U-Mo powders of an irradiated dispersion fuel.

  3. Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection

    Science.gov (United States)

    Prombonas, Anthony; Yannikakis, Stavros; Karampotsos, Thanasis; Katsarou, Martha-Spyridoula; Drakoulis, Nikolaos

    2016-01-01

    Introduction Surface integrity of dental elastomeric impression materials that are subjected to disinfection is of major importance for the quality of the final prosthetic restorations. Aim The aim of this qualitative Scanning Electronic Microscopy (SEM) study was to reveal the effects of immersion or ozone disinfection on the surface of four dental elastomeric impression materials. Materials and Methods Four dental elastomeric impression material brands were used (two vinyl polysiloxane silicones, one polyether, and one vinyl polyether silicone). Total of 32 specimens were fabricated, eight from each impression material. Specimens were immersion (0.525% sodium hypochlorite solution or 0.3% benzalkonium chloride solution) or ozone disinfected or served as controls and examined with SEM. Results Surface degradation was observed on several speci-mens disinfected with 0.525% sodium hypochlorite solution. Similar wavy-wrinkling surface structures were observed in almost all specimens, when treated either with 0.3% benzalkonium chloride solution or ozone. Conclusion The SEM images obtained from this study revealed that both immersion disinfectants and ozone show similar impression material surface alterations. Ozone seems to be non-inferior as compared to immersion disinfectants, but superior as to environmental protection. PMID:28208993

  4. Blistering and exfoliation of 304 stainless steel studied by SEM and RBS

    International Nuclear Information System (INIS)

    Braun, M.; Emmoth, B.; Whitton, J.L.

    1981-01-01

    Blistering and exfoliation induced by helium irradiation have been studied in polycrystalline stainless steel with the aim of measuring flake or blister skin thicknesses for different implantation energies in the keV region. The authors present measurements of skin thicknesses determined both by direct SEM observations and RBS techniques. The results of the RBS studies show for all implantation energies used that the thickness measured in target atoms/unit area of a flake equals the calculated implantation range with an accuracy of about 10%. Conversely, the SEM measurements show that swelling gives rise to a geometrical skin thickness much greater than the corresponding implantation range. Thus from the SEM and RBS data swelling as a function of the implantation energy is obtained and the linear relative swelling is shown to be strongly dependent on the energy. In addition a comparison between the skin thickness of blisters and flakes has been made for the same material. Blisters were observed at low implantation temperatures and room temperature while exfoliation occurs at elevated temperatures. The result of this comparison is that within the experimental accuracy the flake and blister thicknesses are the same. (Auth.)

  5. Automated SEM and TEM sample preparation applied to copper/low k materials

    Science.gov (United States)

    Reyes, R.; Shaapur, F.; Griffiths, D.; Diebold, A. C.; Foran, B.; Raz, E.

    2001-01-01

    We describe the use of automated microcleaving for preparation of both SEM and TEM samples as done by SELA's new MC500 and TEMstation tools. The MC500 is an automated microcleaving tool that is capable of producing cleaves with 0.25 μm accuracy resulting in SEM-ready samples. The TEMstation is capable of taking a sample output from the MC500 (or from SELA's earlier MC200 tool) and producing a FIB ready slice of 25±5 μm, mounted on a TEM-washer and ready for FIB thinning to electron transparency for TEM analysis. The materials selected for the tool set evaluation mainly included the Cu/TaN/HOSP low-k system. The paper is divided into three sections, experimental approach, SEM preparation and analysis of HOSP low-k, and TEM preparation and analysis of Cu/TaN/HOSP low-k samples. For the samples discussed, data is presented to show the quality of preparation provided by these new automated tools.

  6. Valores e motivações para responder sem preconceito frente a homossexuais

    Directory of Open Access Journals (Sweden)

    Valdiney Veloso Gouveia

    2012-06-01

    Full Text Available Neste artigo se objetivou conhecer os correlatos valorativos das motivações interna e externa para encarar sem preconceito a homossexualidade. Foram realizados dois estudos. No Estudo 1 participaram 234 pessoas de João Pessoa, com idade média de 26 anos, que responderam à Escala de Motivações para Responder sem Precocietos Frente a Gays e ao Questionário dos Valores Básicos e perguntas demográficas. A motivação interna se correlacionou com as subfunções suprapessoal (+ e normativa (-, enquanto a motivação externa o fez com existência (+ e normativa (+. O Estudo 2 reuniu 202 pessoas da mesma população, com idade média de 25 anos. Elas responderam os mesmos instrumentos, tendo as lésbicas como grupo-alvo. As motivações interna e externa se correlacionaram com a subfunção normativa (- e +, respectivamente. Concluindo, os valores predisseram adequadamente as motivações para olhar sem preconceito a homossexualidade e os achados foram discutidos a partir do modelo dual de valores.

  7. SEM characterization of an irradiated monolithic U-10Mo fuel plate

    International Nuclear Information System (INIS)

    Keiser, D.D. Jr.; Jue, J.F.; Robinson, A.B.; Finlay, M.R.

    2010-01-01

    Results of scanning electron microscopy (SEM) characterization of irradiated U-7Mo dispersion fuel plates with differing amounts of matrix Si have been reported. However, to date, no results of SEM analysis of irradiated U-Mo monolithic fuel plates have been reported. This paper describes the first SEM characterization results for an irradiated monolithic U-10Mo fuel plate. Two samples from this fuel plate were characterized. One sample was produced from the low-flux side of the fuel plate, and another was produced at the high-flux side of the fuel plate. This characterization focused on the microstructural features present at the U-10Mo foil/AA6061 cladding interface, particularly the interaction zone that had developed during fabrication and any continued development during irradiation. In addition, the microstructure of the foil itself was investigated, along with the morphology of the observed fission gas bubbles. It was observed that a Si-rich interaction layer was present at the U-10Mo foil/cladding interface that exhibited relatively good irradiation behavior, and within the U-10Mo foil the microstructural features differed in some respects from what is typically seen in the U-7Mo powders of an irradiated dispersion fuel. (author)

  8. A hybrid 3D SEM reconstruction method optimized for complex geologic material surfaces.

    Science.gov (United States)

    Yan, Shang; Adegbule, Aderonke; Kibbey, Tohren C G

    2017-08-01

    Reconstruction methods are widely used to extract three-dimensional information from scanning electron microscope (SEM) images. This paper presents a new hybrid reconstruction method that combines stereoscopic reconstruction with shape-from-shading calculations to generate highly-detailed elevation maps from SEM image pairs. The method makes use of an imaged glass sphere to determine the quantitative relationship between observed intensity and angles between the beam and surface normal, and the detector and surface normal. Two specific equations are derived to make use of image intensity information in creating the final elevation map. The equations are used together, one making use of intensities in the two images, the other making use of intensities within a single image. The method is specifically designed for SEM images captured with a single secondary electron detector, and is optimized to capture maximum detail from complex natural surfaces. The method is illustrated with a complex structured abrasive material, and a rough natural sand grain. Results show that the method is capable of capturing details such as angular surface features, varying surface roughness, and surface striations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Detection of glass particles on bone lesions using SEM-EDS.

    Science.gov (United States)

    Montoriol, Romain; Guilbeau-Frugier, Céline; Chantalat, Elodie; Roumiguié, Mathieu; Delisle, Marie-Bernadette; Payré, Bruno; Telmon, Norbert; Savall, Frédéric

    2017-09-01

    The problem of identifying the wounding agent in forensic cases is recurrent. Moreover, when several tools are involved, distinguishing the origin of lesions can be difficult. Scanning electron microscopy (SEM)/energy dispersive X-ray analysis (EDS) equipment is increasingly available to the scientific and medical community, and some studies have reported its use in forensic anthropology. However, at our knowledge, no study has reported the use of SEM-EDS in forensic cases involving glass tools, whether in case reports or experiments. We performed an experimental study on human rib fragments, on which we manually created wounds using fragments of window and mirror glass. SEM-EDS was executed on samples without any further preparation on low vacuum mode, then on the same samples after defleshing them completely by boiling them. Window and mirror glass particles were detected on experimental wounds. Both had silica in their spectra, and the opaque side of the mirror contained titanium, allowing for their identification. Boiling and defleshing the bone samples involved a loss of information in terms of the number of wounds detected as positive for glass particles and in the number of glass particles detected, for both window and mirror glass. We suggest the analysis of wounds with suspected glass particles using low vacuum mode and with no defleshment by boiling.

  10. Enhanced FIB-SEM systems for large-volume 3D imaging

    Science.gov (United States)

    Xu, C Shan; Hayworth, Kenneth J; Lu, Zhiyuan; Grob, Patricia; Hassan, Ahmed M; García-Cerdán, José G; Niyogi, Krishna K; Nogales, Eva; Weinberg, Richard J; Hess, Harald F

    2017-01-01

    Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 106 µm3. These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology. DOI: http://dx.doi.org/10.7554/eLife.25916.001 PMID:28500755

  11. In-SEM Raman microspectroscopy coupled with EDX - a case study of uranium reference particles

    International Nuclear Information System (INIS)

    Stefaniak, Elzbieta A.; Pointurier, Fabien; Marie, Olivier; Truyens, Jan; Aregbe, Yetunde

    2014-01-01

    Information about the molecular composition of airborne uranium-bearing particles may be useful as an additional tool for nuclear safeguards. In order to combine the detection of micrometer-sized particles with the analysis of their molecular forms, we used a hybrid system enabling Raman microanalysis in high vacuum inside a SEM chamber (SEM-SCA system). The first step involved an automatic scan of a sample to detect and save coordinates of uranium particles, along with X-ray microanalysis. In the second phase, the detected particles were relocated in a white light image and subjected to Raman microanalysis. The consecutive measurements by the two beams showed exceptional fragility of uranium particles, leading to their ultimate damage and change of uranium oxidation state. We used uranium reference particles prepared by hydrolysis of uranium hexafluoride to test the reliability of the Raman measurements inside the high vacuum. The results achieved by the hybrid system were verified by using a standalone Raman micro spectrometer. When deposited on exceptionally smooth substrates, uranyl fluoride particles smaller than 1000 nm could successfully be analyzed with the SEM-SCA system. (authors)

  12. Direct comparison of AFM and SEM measurements on the same set of nanoparticles

    International Nuclear Information System (INIS)

    Delvallée, A; Feltin, N; Ducourtieux, S; Trabelsi, M; Hochepied, J F

    2015-01-01

    This article is the first step in the development of a hybrid metrology combining AFM and SEM techniques for measuring the dimensions of a nanoparticle population in 3D space (X,Y,Z). This method exploits the strengths of each technique on the same set of nanoparticles. AFM is used for measuring the nanoparticle height and the measurements along X and Y axes are deduced from SEM images. A sampling method is proposed in order to obtain the best deposition conditions of SiO 2 and gold nanoparticles on mica or silicon substrates. Only the isolated nanoparticles are taken into account in the histogram of size distribution. Moreover, a semi-automatic Matlab routine has also been developed to process the AFM and SEM images, measure and count the nanoparticles. This routine allows the user to exclusively select the isolated nanoparticles through a control interface. The measurements have been performed on spherical-like nanoparticles to test the method by comparing the results obtained with both techniques. (paper)

  13. Influence of blue light spectrum filter on short-wavelength and standard automated perimetries Influência de filtro para o espectro azul da luz na perimetria computadorizada branco-branco e azul-amarelo

    Directory of Open Access Journals (Sweden)

    Leonardo Cunha Castro

    2006-10-01

    Full Text Available PURPOSE: To evaluate the influence of a blue light spectrum filter (BLSF, similar in light spectrum transmittance to the intraocular lens Acrysof NaturalTM, on standard automated perimetry (SAP and short-wavelength automated perimetry (SWAP. METHODS: Twenty young individuals (OBJETIVO: Avaliar a influência de um filtro para o espectro azul da luz, semelhante à lente intra-ocular Acrysof Natural®, nos exames de perimetria automatizada padrão (branco-no-branco e de comprimento de onda curto (azul-no-amarelo. MÉTODOS: Vinte pacientes jovens sem alterações oculares (20 olhos realizaram seqüência de 4 exames de campo visual: perimetria automatizada padrão e azul-no-amarelo com e sem o filtro para o espectro azul da luz. Os índices de limiar foveal (FT, desvio médio (MD e desvio-padrão (PSD obtidos em todos os exames e a diferença causada pela excentricidade nos exames de perimetria automatizada azul-no-amarelo foram analisados. Variabilidade interindivíduos (desvio-padrão dos pontos testados foi calculada. RESULTADOS: Observou-se redução estatisticamente significante no desvio médio (p<0.001 e no limiar foveal (p<0.001 medidos pela perimetria automatizada azul-no-amarelo com o uso do filtro para o espectro azul da luz comparado quando realizado sem o filtro. Nenhum outro índice avaliado apresentou diferença estatisticamente significante nos exames de perimetria automatizada padrão ou azul-no-amarelo. Foi notado aumento da variabilidade interindivíduos com a excentricidade nos exames de perimetria automatizada azul-no-amarelo com e sem o uso do filtro para o espectro azul da luz, assim como a diferença de sensibilidade entre os hemisférios inferior e superior (hemisfério inferior menos superior, mas não houve diferença estatisticamente significante quando comparados os exames com e sem o uso do filtro. Quando foram comparados os 4 pontos mais inferiores e os 4 pontos mais superiores, a diferença inferior-superior aumentou

  14. Quantitative Determination of Noa (Naturally Occurring Asbestos) in Rocks : Comparison Between Pcom and SEM Analysis

    Science.gov (United States)

    Baietto, Oliviero; Amodeo, Francesco; Giorgis, Ilaria; Vitaliti, Martina

    2017-04-01

    The quantification of NOA (Naturally Occurring Asbestos) in a rock or soil matrix is complex and subject to numerous errors. The purpose of this study is to compare two fundamental methodologies used for the analysis: the first one uses Phase Contrast Optical Microscope (PCOM) while the second one uses Scanning Electron Microscope (SEM). The two methods, although they provide the same result, which is the asbestos mass to total mass ratio, have completely different characteristics and both present pros and cons. The current legislation in Italy involves the use of SEM, DRX, FTIR, PCOM (DM 6/9/94) for the quantification of asbestos in bulk materials and soils and the threshold beyond which the material is considered as hazardous waste is a concentration of asbestos fiber of 1000 mg/kg.(DM 161/2012). The most used technology is the SEM which is the one among these with the better analytical sensitivity.(120mg/Kg DM 6 /9/94) The fundamental differences among the analyses are mainly: - Amount of analyzed sample portion - Representativeness of the sample - Resolution - Analytical precision - Uncertainty of the methodology - Operator errors Due to the problem of quantification of DRX and FTIR (1% DM 6/9/94) our Asbestos Laboratory (DIATI POLITO) since more than twenty years apply the PCOM methodology and in the last years the SEM methodology for quantification of asbestos content. The aim of our research is to compare the results obtained from a PCOM analysis with the results provided by SEM analysis on the base of more than 100 natural samples both from cores (tunnel-boring or explorative-drilling) and from tunnelling excavation . The results obtained show, in most cases, a good correlation between the two techniques. Of particular relevance is the fact that both techniques are reliable for very low quantities of asbestos, even lower than the analytical sensitivity. This work highlights the comparison between the two techniques emphasizing strengths and weaknesses of

  15. SEM AutoAnalysis: enhancing photomask and NIL defect disposition and review

    Science.gov (United States)

    Schulz, Kristian; Egodage, Kokila; Tabbone, Gilles; Ehrlich, Christian; Garetto, Anthony

    2017-06-01

    For defect disposition and repair verification regarding printability, AIMS™ is the state of the art measurement tool in industry. With its unique capability of capturing aerial images of photomasks it is the one method that comes closest to emulating the printing behaviour of a scanner. However for nanoimprint lithography (NIL) templates aerial images cannot be applied to evaluate the success of a repair process. Hence, for NIL defect dispositioning scanning, electron microscopy (SEM) imaging is the method of choice. In addition, it has been a standard imaging method for further root cause analysis of defects and defect review on optical photomasks which enables 2D or even 3D mask profiling at high resolutions. In recent years a trend observed in mask shops has been the automation of processes that traditionally were driven by operators. This of course has brought many advantages one of which is freeing cost intensive labour from conducting repetitive and tedious work. Furthermore, it reduces variability in processes due to different operator skill and experience levels which at the end contributes to eliminating the human factor. Taking these factors into consideration, one of the software based solutions available under the FAVOR® brand to support customer needs is the aerial image evaluation software, AIMS™ AutoAnalysis (AAA). It provides fully automated analysis of AIMS™ images and runs in parallel to measurements. This is enabled by its direct connection and communication with the AIMS™tools. As one of many positive outcomes, generating automated result reports is facilitated, standardizing the mask manufacturing workflow. Today, AAA has been successfully introduced into production at multiple customers and is supporting the workflow as described above. These trends indeed have triggered the demand for similar automation with respect to SEM measurements leading to the development of SEM AutoAnalysis (SAA). It aims towards a fully automated SEM image

  16. Enabling CD SEM metrology for 5nm technology node and beyond

    Science.gov (United States)

    Lorusso, Gian Francesco; Ohashi, Takeyoshi; Yamaguchi, Astuko; Inoue, Osamu; Sutani, Takumichi; Horiguchi, Naoto; Bömmels, Jürgen; Wilson, Christopher J.; Briggs, Basoene; Tan, Chi Lim; Raymaekers, Tom; Delhougne, Romain; Van den Bosch, Geert; Di Piazza, Luca; Kar, Gouri Sankar; Furnémont, Arnaud; Fantini, Andrea; Donadio, Gabriele Luca; Souriau, Laurent; Crotti, Davide; Yasin, Farrukh; Appeltans, Raf; Rao, Siddharth; De Simone, Danilo; Rincon Delgadillo, Paulina; Leray, Philippe; Charley, Anne-Laure; Zhou, Daisy; Veloso, Anabela; Collaert, Nadine; Hasumi, Kazuhisa; Koshihara, Shunsuke; Ikota, Masami; Okagawa, Yutaka; Ishimoto, Toru

    2017-03-01

    The CD SEM (Critical Dimension Scanning Electron Microscope) is one of the main tools used to estimate Critical Dimension (CD) in semiconductor manufacturing nowadays, but, as all metrology tools, it will face considerable challenges to keep up with the requirements of the future technology nodes. The root causes of these challenges are not uniquely related to the shrinking CD values, as one might expect, but to the increase in complexity of the devices in terms of morphology and chemical composition as well. In fact, complicated threedimensional device architectures, high aspect ratio features, and wide variety of materials are some of the unavoidable characteristics of the future metrology nodes. This means that, beside an improvement in resolution, it is critical to develop a CD SEM metrology capable of satisfying the specific needs of the devices of the nodes to come, needs that sometimes will have to be addressed through dramatic changes in approach with respect to traditional CD SEM metrology. In this paper, we report on the development of advanced CD SEM metrology at imec on a variety of device platform and processes, for both logic and memories. We discuss newly developed approaches for standard, IIIV, and germanium FinFETs (Fin Field Effect Transistors), for lateral and vertical nanowires (NW), 3D NAND (three-dimensional NAND), STT-MRAM (Spin Transfer Magnetic Torque Random-Access Memory), and ReRAM (Resistive Random Access Memory). Applications for both front-end of line (FEOL) and back-end of line (BEOL) are developed. In terms of process, S/D Epi (Source Drain Epitaxy), SAQP (Self-Aligned Quadruple Patterning), DSA (Dynamic Self-Assembly), and EUVL (Extreme Ultraviolet Lithography) have been used. The work reported here has been performed on Hitachi CG5000, CG6300, and CV5000. In terms of logic, we discuss here the S/D epi defect classification, the metrology optimization for STI (Shallow Trench Isolation) Ge FinFETs, the defectivity of III-V STI Fin

  17. The ITZ in concrete with natural and recycled aggregates : Study of microstructures based on image and SEM analysis

    NARCIS (Netherlands)

    Bonifazi, G.; Capobianco, G.; Serranti, S.; Eggimann, M.; Wagner, E.; Di Maio, F.; Lotfi, S.

    2015-01-01

    Aim of this work was to investigate the microstructure of the Interfacial Transition Zone (ITZ) between cement paste and aggregate in concrete utilizing Scanning Electron Microscope (SEM) in order to identify possible effects on the ITZ related to different recipes and production parameters. SEM is

  18. SEM-microphotogrammetry, a new take on an old method for generating high-resolution 3D models from SEM images.

    Science.gov (United States)

    Ball, A D; Job, P A; Walker, A E L

    2017-08-01

    The method we present here uses a scanning electron microscope programmed via macros to automatically capture dozens of images at suitable angles to generate accurate, detailed three-dimensional (3D) surface models with micron-scale resolution. We demonstrate that it is possible to use these Scanning Electron Microscope (SEM) images in conjunction with commercially available software originally developed for photogrammetry reconstructions from Digital Single Lens Reflex (DSLR) cameras and to reconstruct 3D models of the specimen. These 3D models can then be exported as polygon meshes and eventually 3D printed. This technique offers the potential to obtain data suitable to reconstruct very tiny features (e.g. diatoms, butterfly scales and mineral fabrics) at nanometre resolution. Ultimately, we foresee this as being a useful tool for better understanding spatial relationships at very high resolution. However, our motivation is also to use it to produce 3D models to be used in public outreach events and exhibitions, especially for the blind or partially sighted. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  19. Comparação entre a correção cilíndrica total e o equivalente esférico na realização da perimetria computadorizada Comparison between the full cylindrical correction and the spherical equivalent in the execution of automated perimetry

    Directory of Open Access Journals (Sweden)

    Paulo Leonardi Filho

    2004-08-01

    Full Text Available OBJETIVO: Verificar a existência de diferença estatisticamente significativa entre exames de campimetria computadorizada, realizados com a utilização da correção total e do equivalente esférico, em pacientes com ametropia cilíndrica de valores iguais ou maiores que 1,50 dioptrias. MÉTODOS: Vinte pacientes (35 olhos foram submetidos a exame de campo visual, perimetria computadorizada Humphrey - estratégia SITA 24-2, usando em um exame a correção total e em outro o equivalente esférico. Foram utilizados como parâmetros de comparação os valores de Mean Deviation, Pattern Standard Deviation, perdas de fixação, falso-positivos, falso-negativos e duração dos exames. RESULTADOS: Os parâmetros Mean Deviation, Standard Pattern Deviation, falso-positivos, falso-negativos e duração do exame não apresentaram diferença estatisticamente significativa. A perda de fixação foi maior no grupo usando correção cilíndrica total, dado estatisticamente significante. CONCLUSÃO: Exames de campo visual realizados com equivalente esférico não mostram diferença na sensibilidade retínica quando comparados com o uso de correção cilíndrica total, dentro dos padrões adotados neste estudo.PURPOSE: To compare the results in subjects undergoing visual field testing using the full cylindrical correction and the spherical equivalent. METHODS: Twenty patients (35 eyes underwent visual field testing with Humphrey (SITA 24-2 perimetry using the full cylindrical correction and the spherical equivalent at a random sequence. Mean Deviation, Standard Pattern Deviation, fixation loss, false positive and false negative results and test duration were compared. RESULTS: No difference was found regarding Mean Deviation, Standard Pattern Deviation, false positive and false negative results and test duration. Fixation loss was significantly higher with the full cylindrical correction. CONCLUSION: Visual fields performed with the spherical equivalent show no

  20. Tuberculose pulmonar: achados na tomografia computadorizada de alta resolução do tórax em pacientes com doença em atividade comprovada bacteriologicamente Pulmonary tuberculosis: findings on high resolution computerized tomography of active disease on patients with bacteriological confirmation

    Directory of Open Access Journals (Sweden)

    CRISTIANE ALÓ CAMPOS

    2002-01-01

    Full Text Available Objetivo: Descrever os achados em pacientes com tuberculose pulmonar em atividade na tomografia computadorizada de alta resolução e o padrão de distribuição das lesões pelo parênquima pulmonar. Casuística e método: Foram analisadas retrospectivamente as tomografias de alta resolução de 42 pacientes com diagnóstico bacteriológico de tuberculose pulmonar ou forte suspeita clínica, com posterior confirmação bacteriológica. Resultados: Os principais sinais sugestivos de atividade encontrados foram nódulos do espaço aéreo (83%, nódulos centrolobulares (74%, aspecto de árvore em brotamento (67%, cavitações (67%, espessamento das paredes brônquicas (55%, consolidações (48%, opacidade em vidro fosco (21%, e espessamento do interstício pulmonar (9%. Conclusão: A tomografia computadorizada de alta resolução do tórax pode sugerir fortemente atividade da doença, sendo particularmente útil nos pacientes com baciloscopias negativas e/ou radiografias indeterminadas, permitindo a instituição de tratamento adequado, antes mesmo do crescimento da micobactéria em meio de cultura.Background: The aim of this study was to describe the signs of active tuberculosis in patients submitted to high resolution computerized tomography and the distribution of lesions along the pulmonary parenchyma. Material and methods: The high resolution CTs performed on 42 patients with tuberculosis either bacteriologically diagnosed or clinical suspected and later confirmed by bacteriological tests were studied. Results: The signs of disease activity observed were airspace nodule (83%, centrilobular nodule (74%, tree-in-bud pattern (67%, cavitations (67%, bronchial thickening (55%, parenchymal consolidations (48%, ground glass opacity (21% and thickening of the inter and intralobular septa (9%. Conclusion: High resolution computed tomography can be strongly suggestive of disease activity, is particularly helpful in patients with negative smear and

  1. Influence of estrogen deficiency and tibolone therapy on trabecular and cortical bone evaluated by computed radiography system in rats Influência da deficiência estrogênica e do tratamento com tibolona no osso trabecular e cortical avaliada pelo sistema de radiografia computadorizada em ratas

    Directory of Open Access Journals (Sweden)

    Ana Carolina Bergmann de Carvalho

    2012-03-01

    Full Text Available PURPOSE: To verify the effects of tibolone administration on trabecular and cortical bone of ovariectomized female rats by computed radiography system (CRS. METHODS: The experiment was performed on two groups of rats previously ovariectomized, one received tibolone (OVX+T while the other did not (OVX, those groups were compared to a control group (C not ovariectomized. Tibolone administration (1mg/day began thirty days after the ovariectomy and the treatment remained for five months. At last, the animals were euthanized and femurs and tibias collected. Computed radiographies of the bones were obtained and the digital images were used to determine the bone optical density and cortical thickness on every group. All results were statistically evaluated with significance set at POBJETIVO: Verificar o efeito da administração de tibolona no tecido ósseo cortical e trabecular de ratas castradas através de radiografia computadorizada. MÉTODOS: O experimento foi realizado em dois grupos de ratas previamente ooforectomizadas, onde um grupo recebeu tibolona (OVX+T e o outro não (OVX. Esses grupos foram comparados a um grupo controle (C não ooforectomizado. A administração de tibolona (1mg/dia começou trinta dias após a ooforectomia e o tratamento teve duração de cinco meses. No final, os animais foram mortos e fêmures e tibias coletados. As radiografias computadorizadas dos ossos foram obtidas e as imagens digitais usadas para determinar a densidade óssea e a espessura cortical em todos os grupos. Todos os resultados foram avaliados estatisticamente com significância estabelecida a 5%. RESULTADOS: A administração de tibolona mostrou ser benéfica apenas para análise densitométrica da cabeça do fêmur, apresentando maiores valores de densidade comparada ao grupo OVX. Nenhuma diferença significativa foi encontrada para espessura óssea cortical. CONCLUSÃO: A ooforectomia ocasionou perda óssea nas regiões analisadas e a tibolona

  2. Computed tomography image of the mediastinal and axillary lymph nodes in clinically sound Rottweilers Imagem por tomografia computadorizada dos linfonodos axilares e mediastinais de cães rottweilers clinicamente saudáveis

    Directory of Open Access Journals (Sweden)

    Ana Carolina B. Fonseca Pinto

    2013-03-01

    smallest diameter of the axillary and mediastinal lymph nodes not surpassed 7mm and 8mm respectively. Their attenuations were equal or smaller than that of musculature in the post contrast scan.A tomografia computadorizada é uma modalidade diagnóstica que possibilita a avaliação detalhada dos linfonodos e que é capaz de detectar mais precocemente alterações envolvendo estas estruturas, que modalidades de imagem como a radiografia e a ultrassonografia. Tendo em vista a escassez de informações na literatura veterinária esta pesquisa objetivou fornecer informações sobre os aspectos tomográficos normais dos linfonodos axilares e mediastinais em cães. Realizou-se o exame tomográfico de 15 cães adultos, machos e fêmeas, da raça Rottweiler, selecionados como clinicamente normais por meio de anamnese, exame físico, hemograma, perfil bioquímico renal e hepático, eletrocardiograma e exame radiográfico do tórax. Após a injeção intravenosa do contraste iodado hidrossolúvel iônico, realizaram-se cortes tomográficos transversais do tórax com 10mm de espessura e 10mm de incremento em um tomógrafo axial. Os exames tomográficos foram avaliados buscando-se identificar os linfonodos axilares e mediastinais. Quando visibilizados, os linfonodos foram mensurados em seu menor eixo e sua atenuação foi comparada com a da musculatura. Foram calculados a média e desvio padrão da idade, do peso, do comprimento dos animais e do menor eixo dos linfonodos axilares e mediastinais. A média de idade dos animais e o desvio padrão foram de 3,87 anos ±2,03, do peso foi de 41,13kg ± 5,12 e do comprimento dos animais foi de 89,61cm ±2,63. Os linfonodos axilares foram visibilizados em 60% dos animais, a média das mensurações dos menores diâmetros e o desvio padrão foi de 3,58mm ±2,02 com valor mínimo de 1mm e máximo de 7mm. Dos 13 linfonodos observados 61,53% apresentaram-se hipoatenuantes comparativamente a musculatura e 30,77% isoatenuantes. Os linfonodos

  3. The C. elegans Spalt-like protein SEM-4 functions through the SoxC transcription factor SEM-2 to promote a proliferative blast cell fate in the postembryonic mesoderm.

    Science.gov (United States)

    Shen, Qinfang; Shi, Herong; Tian, Chenxi; Ghai, Vikas; Liu, Jun

    2017-09-01

    Proper development of a multicellular organism relies on well-coordinated regulation of cell fate specification, cell proliferation and cell differentiation. The C. elegans postembryonic mesoderm provides a useful system for uncovering factors involved in these processes and for further dissecting their regulatory relationships. The single Spalt-like zinc finger containing protein SEM-4/SALL is known to be involved in specifying the proliferative sex myoblast (SM) fate. We have found that SEM-4/SALL is sufficient to promote the SM fate and that it does so in a cell autonomous manner. We further showed that SEM-4/SALL acts through the SoxC transcription factor SEM-2 to promote the SM fate. SEM-2 is known to promote the SM fate by inhibiting the expression of two BWM-specifying transcription factors. In light of recent findings in mammals showing that Sall4, one of the mammalian homologs of SEM-4, contributes to pluripotency regulation by inhibiting differentiation, our work suggests that the function of SEM-4/SALL proteins in regulating pluripotency versus differentiation appears to be evolutionarily conserved. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Mechatronic Development and Vision Feedback Control of a Nanorobotics Manipulation System inside SEM for Nanodevice Assembly

    Directory of Open Access Journals (Sweden)

    Zhan Yang

    2016-09-01

    Full Text Available Carbon nanotubes (CNT have been developed in recent decades for nanodevices such as nanoradios, nanogenerators, carbon nanotube field effect transistors (CNTFETs and so on, indicating that the application of CNTs for nanoscale electronics may play a key role in the development of nanotechnology. Nanorobotics manipulation systems are a promising method for nanodevice construction and assembly. For the purpose of constructing three-dimensional CNTFETs, a nanorobotics manipulation system with 16 DOFs was developed for nanomanipulation of nanometer-scale objects inside the specimen chamber of a scanning electron microscope (SEM. Nanorobotics manipulators are assembled into four units with four DOFs (X-Y-Z-θ individually. The rotational one is actuated by a picomotor. That means a manipulator has four DOFs including three linear motions in the X, Y, Z directions and a 360-degree rotational one (X-Y-Z-θ stage, θ is along the direction rotating with X or Y axis. Manipulators are actuated by picomotors with better than 30 nm linear resolution and <1 micro-rad rotary resolution. Four vertically installed AFM cantilevers (the axis of the cantilever tip is vertical to the axis of electronic beam of SEM served as the end-effectors to facilitate the real-time observation of the operations. A series of kinematic derivations of these four manipulators based on the Denavit-Hartenberg (D-H notation were established. The common working space of the end-effectors is 2.78 mm by 4.39 mm by 6 mm. The manipulation strategy and vision feedback control for multi-manipulators operating inside the SEM chamber were been discussed. Finally, application of the designed nanorobotics manipulation system by successfully testing of the pickup-and-place manipulation of an individual CNT onto four probes was described. The experimental results have shown that carbon nanotubes can be successfully picked up with this nanorobotics manipulation system.

  5. Specimen's plane misaligned installation solution based on charge fluctuation inside SEM

    Science.gov (United States)

    Lu, Haojian; Liu, Yanting; Yang, Yuanyuan; Wang, Panbing; Shen, Yajing

    2018-04-01

    Precise specimen's installation is a sticking point to ensure the characterization accuracy of the in-situ material property test. Although it is common knowledge that specimen's plane misaligned installation (PMI) would cause extra force loading during mechanical testing, there are few effective solutions available to deal with it at the current stage, especially during the in-situ scanning electron microscopy (SEM) test. Taking into consideration the charge fluctuation phenomenon under SEM, this paper proposes a highlight area variation (HAV) method for specimen deformation judgment, i.e., the specimen deformation is defined when the highlight area changes greater than 20% of the initial value of the specimen surface. Three types of specimens with different resistivities, i.e., human hair (electrical resistivity ˜3 × 1012 Ω cm), optical fiber (electrical resistivity ˜1017 Ω cm), and magnetic wire (electrical resistivity ˜2 × 10-5 Ω cm), are chosen to verify the effectiveness of the HAV method. Furthermore, combined with the developed robot-aided alignment system, the specimen's PMI problem can also be solved. In the demonstration, the human hair specimen is installed across two specimen stages and its in-situ twisting (in 360°) test is implemented. The results clearly indicate that the HAV method and the robot-aided alignment system are practical and reliable, and the specimen can be aligned on the same plane and installed precisely with accuracy up to 3 μm. This method will benefit the in-situ SEM material mechanical property test and has a significant impact in fundamental material research.

  6. Nanosecond pulsed laser ablation of Ge investigated by employing photoacoustic deflection technique and SEM analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yaseen, Nazish; Bashir, Shazia; Shabbir, Muhammad Kaif; Jalil, Sohail Abdul; Akram, Mahreen; Hayat, Asma; Mahmood, Khaliq; Haq, Faizan-ul; Ahmad, Riaz; Hussain, Tousif

    2016-06-01

    Nanosecond pulsed laser ablation phenomena of single crystal Ge (100) has been investigated by employing photoacoustic deflection as well as SEM analysis techniques. Nd: YAG laser (1064 nm, 10 ns, 1–10 Hz) at various laser fluences ranging from 0.2 to 11 J cm{sup −2} is employed as pump beam to ablate Ge targets. In order to evaluate in-situe ablation threshold fluence of Ge by photoacoustic deflection technique, Continuous Wave (CW) He–Ne laser (632 nm, power 10 mW) is employed as a probe beam. It travels parallel to the target surface at a distance of 3 mm and after passing through Ge plasma it causes deflection due to density gradient of acoustic waves. The deflected signal is detected by photodiode and is recorded by oscilloscope. The threshold fluence of Ge, the velocity of ablated species and the amplitude of the deflected signal are evaluated. The threshold fluence of Ge comes out to be 0.5 J cm{sup −2} and is comparable with the analytical value. In order to compare the estimated value of threshold with ex-situe measurements, the quantitative analysis of laser irradiated Ge is performed by using SEM analysis. For this purpose Ge is exposed to single and multiple shots of 5, 10, 50 and 100 at various laser fluences ranging from 0.2 to 11 J cm{sup −2}. The threshold fluence for single and multiple shots as well as incubation coefficients are evaluated. It is observed that the value of incubation co-efficient decreases with increasing number of pulses and is therefore responsible for lowering the threshold fluence of Ge. SEM analysis also reveals the growth of various features such as porous structures, non-uniform ripples and blisters on the laser irradiated Ge. It is observed that both the fluence as well as number of laser shots plays a significant role for the growth of these structures.

  7. Nanosecond pulsed laser ablation of Ge investigated by employing photoacoustic deflection technique and SEM analysis

    International Nuclear Information System (INIS)

    Yaseen, Nazish; Bashir, Shazia; Shabbir, Muhammad Kaif; Jalil, Sohail Abdul; Akram, Mahreen; Hayat, Asma; Mahmood, Khaliq; Haq, Faizan-ul; Ahmad, Riaz; Hussain, Tousif

    2016-01-01

    Nanosecond pulsed laser ablation phenomena of single crystal Ge (100) has been investigated by employing photoacoustic deflection as well as SEM analysis techniques. Nd: YAG laser (1064 nm, 10 ns, 1–10 Hz) at various laser fluences ranging from 0.2 to 11 J cm"−"2 is employed as pump beam to ablate Ge targets. In order to evaluate in-situe ablation threshold fluence of Ge by photoacoustic deflection technique, Continuous Wave (CW) He–Ne laser (632 nm, power 10 mW) is employed as a probe beam. It travels parallel to the target surface at a distance of 3 mm and after passing through Ge plasma it causes deflection due to density gradient of acoustic waves. The deflected signal is detected by photodiode and is recorded by oscilloscope. The threshold fluence of Ge, the velocity of ablated species and the amplitude of the deflected signal are evaluated. The threshold fluence of Ge comes out to be 0.5 J cm"−"2 and is comparable with the analytical value. In order to compare the estimated value of threshold with ex-situe measurements, the quantitative analysis of laser irradiated Ge is performed by using SEM analysis. For this purpose Ge is exposed to single and multiple shots of 5, 10, 50 and 100 at various laser fluences ranging from 0.2 to 11 J cm"−"2. The threshold fluence for single and multiple shots as well as incubation coefficients are evaluated. It is observed that the value of incubation co-efficient decreases with increasing number of pulses and is therefore responsible for lowering the threshold fluence of Ge. SEM analysis also reveals the growth of various features such as porous structures, non-uniform ripples and blisters on the laser irradiated Ge. It is observed that both the fluence as well as number of laser shots plays a significant role for the growth of these structures.

  8. Tumor suppressor protein SMAR1 modulates the roughness of cell surface: combined AFM and SEM study

    Directory of Open Access Journals (Sweden)

    Mamgain Hitesh

    2009-10-01

    Full Text Available Abstract Background Imaging tools such as scanning electron microscope (SEM and atomic force microscope (AFM can be used to produce high-resolution topographic images of biomedical specimens and hence are well suited for imaging alterations in cell morphology. We have studied the correlation of SMAR1 expression with cell surface smoothness in cell lines as well as in different grades of human breast cancer and mouse tumor sections. Methods We validated knockdown and overexpression of SMAR1 using RT-PCR as well as Western blotting in human embryonic kidney (HEK 293, human breast cancer (MCF-7 and mouse melanoma (B16F1 cell lines. The samples were then processed for cell surface roughness studies using atomic force microscopy (AFM and scanning electron microscopy (SEM. The same samples were used for microarray analysis as well. Tumors sections from control and SMAR1 treated mice as well as tissues sections from different grades of human breast cancer on poly L-lysine coated slides were used for AFM and SEM studies. Results Tumor sections from mice injected with melanoma cells showed pronounced surface roughness. In contrast, tumor sections obtained from nude mice that were first injected with melanoma cells followed by repeated injections of SMAR1-P44 peptide, exhibited relatively smoother surface profile. Interestingly, human breast cancer tissue sections that showed reduced SMAR1 expression exhibited increased surface roughness compared to the adjacent normal breast tissue. Our AFM data establishes that treatment of cells with SMAR1-P44 results into increase in cytoskeletal volume that is supported by comparative gene expression data showing an increase in the expression of specific cytoskeletal proteins compared to the control cells. Altogether, these findings indicate that tumor suppressor function of SMAR1 might be exhibited through smoothening of cell surface by regulating expression of cell surface proteins. Conclusion Tumor suppressor

  9. Application of FE-SEM with elemental analyzer for irradiated fuel materials

    International Nuclear Information System (INIS)

    Sasaki, Shinji; Maeda, Koji; Yamada, A.

    2012-01-01

    It is important to study the irradiation behavior of the uranium-plutonium mixed oxide fuels (MOX fuels) for development of fast reactor fuels. During irradiation in a fast reactor, the changes of microstructures and the changes of element distributions along radial direction occur in the MOX fuels because of a radial temperature gradient. In order to make detailed observations of microstructure and elemental analyses of fuel samples, a field emission scanning electron microscope (FE-SEM) equipped with a wavelength-dispersive X-ray spectrometer (WDX) and an energy-dispersive X-ray spectrometer (EDX) were installed in a hot laboratory. Because fuel samples have high radioactivities and emit α-particles, the instrument was modified correspondingly. The notable modified points were as follows. 1) To prevent leakage of radioactive materials, the instrument was attached to a remote control air-tight sample transfer unit between a shielded hot cell and the FE-SEM. 2) To protect operators and the instruments from radiation, the FE-SEM was installed in a lead shield box and the control unit was separately located outside the box. After the installation, the microscopy and elemental analyses were made on low burnup fuel samples. High resolution images were obtained on the fuel sample surface. The characteristic X-rays (U, Pu) emitted from the fuel sample surface measured along radial direction successfully. Thereby, it was able to grasp the change of U, Pu radial distribution after irradiation. The technique has the great advantage of being able to evaluate the changes of microstructures and the changes of element distributions of MOX fuels due to irradiation. In future work, samples of even higher radioactivity will be observed and analyzed. (author)

  10. Mechatronic Development and Vision Feedback Control of a Nanorobotics Manipulation System inside SEM for Nanodevice Assembly

    Science.gov (United States)

    Yang, Zhan; Wang, Yaqiong; Yang, Bin; Li, Guanghui; Chen, Tao; Nakajima, Masahiro; Sun, Lining; Fukuda, Toshio

    2016-01-01

    Carbon nanotubes (CNT) have been developed in recent decades for nanodevices such as nanoradios, nanogenerators, carbon nanotube field effect transistors (CNTFETs) and so on, indicating that the application of CNTs for nanoscale electronics may play a key role in the development of nanotechnology. Nanorobotics manipulation systems are a promising method for nanodevice construction and assembly. For the purpose of constructing three-dimensional CNTFETs, a nanorobotics manipulation system with 16 DOFs was developed for nanomanipulation of nanometer-scale objects inside the specimen chamber of a scanning electron microscope (SEM). Nanorobotics manipulators are assembled into four units with four DOFs (X-Y-Z-θ) individually. The rotational one is actuated by a picomotor. That means a manipulator has four DOFs including three linear motions in the X, Y, Z directions and a 360-degree rotational one (X-Y-Z-θ stage, θ is along the direction rotating with X or Y axis). Manipulators are actuated by picomotors with better than 30 nm linear resolution and SEM) served as the end-effectors to facilitate the real-time observation of the operations. A series of kinematic derivations of these four manipulators based on the Denavit-Hartenberg (D-H) notation were established. The common working space of the end-effectors is 2.78 mm by 4.39 mm by 6 mm. The manipulation strategy and vision feedback control for multi-manipulators operating inside the SEM chamber were been discussed. Finally, application of the designed nanorobotics manipulation system by successfully testing of the pickup-and-place manipulation of an individual CNT onto four probes was described. The experimental results have shown that carbon nanotubes can be successfully picked up with this nanorobotics manipulation system. PMID:27649180

  11. Is scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) quantitative?

    Science.gov (United States)

    Newbury, Dale E; Ritchie, Nicholas W M

    2013-01-01

    Scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) is a widely applied elemental microanalysis method capable of identifying and quantifying all elements in the periodic table except H, He, and Li. By following the "k-ratio" (unknown/standard) measurement protocol development for electron-excited wavelength dispersive spectrometry (WDS), SEM/EDS can achieve accuracy and precision equivalent to WDS and at substantially lower electron dose, even when severe X-ray peak overlaps occur, provided sufficient counts are recorded. Achieving this level of performance is now much more practical with the advent of the high-throughput silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS). However, three measurement issues continue to diminish the impact of SEM/EDS: (1) In the qualitative analysis (i.e., element identification) that must precede quantitative analysis, at least some current and many legacy software systems are vulnerable to occasional misidentification of major constituent peaks, with the frequency of misidentifications rising significantly for minor and trace constituents. (2) The use of standardless analysis, which is subject to much broader systematic errors, leads to quantitative results that, while useful, do not have sufficient accuracy to solve critical problems, e.g. determining the formula of a compound. (3) EDS spectrometers have such a large volume of acceptance that apparently credible spectra can be obtained from specimens with complex topography that introduce uncontrolled geometric factors that modify X-ray generation and propagation, resulting in very large systematic errors, often a factor of ten or more. © Wiley Periodicals, Inc.

  12. Adapted methods for scanning electron microscopy (SEM in assessment of human sperm morphology

    Directory of Open Access Journals (Sweden)

    Petra Nussdorfer

    2018-02-01

    Full Text Available Infertility is a widespread problem, and in some cases, the routine basic semen analysis is not sufficient to detect the cause of male infertility. The use of the scanning electron microscope (SEM could provide a detailed insight into spermatozoa morphology, but it requires specific sample preparation techniques. The purpose of this study was to select, adjust, and optimize a method for the preparation of spermatozoa samples prior to SEM analysis, and to establish the protocol required for its use in clinical practice. We examined sperm samples of 50 men. The samples were fixed with modified iso-osmolar aldehyde solution followed by osmium post-fixation. In the first method, dehydration of the cells and subsequent critical point drying (CPD were performed on a coverslip. In the second method, the samples were dehydrated in centrifuge tubes; hexamethyldisilazane (HMDS was used as a drying agent instead of CPD, and the samples were air-dried. The third procedure was based on a membrane filter. The samples were dehydrated and dried with HMDS in a Gooch crucible, continuously, without centrifugation or redispersion of the sample. Our results showed that the fixation with modified iso-osmolar aldehyde solution followed by osmium post-fixation, and combined with dehydration and CPD on a coverslip, is the most convenient procedure for SEM sample preparation. In the case of small-size samples or low sperm concentration, dehydration and drying with HMDS on the membrane filter enabled the best reliability, repeatability, and comparability of the results. The presented procedures are suitable for routine use, and they can be applied to confirm as well as to correct a diagnosis.

  13. Mechatronic Development and Vision Feedback Control of a Nanorobotics Manipulation System inside SEM for Nanodevice Assembly.

    Science.gov (United States)

    Yang, Zhan; Wang, Yaqiong; Yang, Bin; Li, Guanghui; Chen, Tao; Nakajima, Masahiro; Sun, Lining; Fukuda, Toshio

    2016-09-14

    Carbon nanotubes (CNT) have been developed in recent decades for nanodevices such as nanoradios, nanogenerators, carbon nanotube field effect transistors (CNTFETs) and so on, indicating that the application of CNTs for nanoscale electronics may play a key role in the development of nanotechnology. Nanorobotics manipulation systems are a promising method for nanodevice construction and assembly. For the purpose of constructing three-dimensional CNTFETs, a nanorobotics manipulation system with 16 DOFs was developed for nanomanipulation of nanometer-scale objects inside the specimen chamber of a scanning electron microscope (SEM). Nanorobotics manipulators are assembled into four units with four DOFs (X-Y-Z-θ) individually. The rotational one is actuated by a picomotor. That means a manipulator has four DOFs including three linear motions in the X, Y, Z directions and a 360-degree rotational one (X-Y-Z-θ stage, θ is along the direction rotating with X or Y axis). Manipulators are actuated by picomotors with better than 30 nm linear resolution and <1 micro-rad rotary resolution. Four vertically installed AFM cantilevers (the axis of the cantilever tip is vertical to the axis of electronic beam of SEM) served as the end-effectors to facilitate the real-time observation of the operations. A series of kinematic derivations of these four manipulators based on the Denavit-Hartenberg (D-H) notation were established. The common working space of the end-effectors is 2.78 mm by 4.39 mm by 6 mm. The manipulation strategy and vision feedback control for multi-manipulators operating inside the SEM chamber were been discussed. Finally, application of the designed nanorobotics manipulation system by successfully testing of the pickup-and-place manipulation of an individual CNT onto four probes was described. The experimental results have shown that carbon nanotubes can be successfully picked up with this nanorobotics manipulation system.

  14. Semântica gramatical: a significação dos pronomes

    Directory of Open Access Journals (Sweden)

    Nildemir Ferreira de Carvalho

    2001-01-01

    Full Text Available

    O estudo analisa a significação das particulas pronominais entre as quais se incluem os determinantes, os pronomes substantivos e os advérbios pronominais. Para esta análise se adota o critério dos traços constrativos (Chomsky, 2. Os resultados do trabalho mostram que as categorias semânticas dos pronomes (lato sensu se associam, de uma forma ou de outra, às nações de DEFINIDADE e PESSOA DO DISCURSO.

  15. Estudo da sintomatologia depressiva e ansiosa em crianças com e sem obesidade

    OpenAIRE

    Morgado, Joana Alexandra da Silva

    2013-01-01

    A obesidade infantil constitui um problema de saúde pública, o que motivou a sua classificação pela WHO como “epidemia do seculo XXI”. Como se não bastasse, surge sempre associada ao aumento quer da mortalidade, quer da morbilidade. Este estudo procura perceber em que medida as crianças com obesidade infantil diferem das crianças sem obesidade em termos de sintomatologia depressiva e ansiosa. O desenho do estudo é de natureza transversal e comparativa. A amostra é composta por 85 crianças, co...

  16. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM

    Czech Academy of Sciences Publication Activity Database

    Bok, Jan; Lalinský, Ondřej; Hanuš, M.; Onderišinová, Z.; Kelar, J.; Kučera, M.

    2016-01-01

    Roč. 163, APR (2016), s. 1-5 ISSN 0304-3991 R&D Projects: GA ČR(CZ) GA14-20012S; GA ČR(CZ) GA16-05631S; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : scintillator * GAGG:Ce * multicomponent garnet * epitaxial film * electron detection * SEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 2.843, year: 2016

  17. XPS and SEM studies of chromium oxide films chemically formed on stainless steel 316 L

    International Nuclear Information System (INIS)

    Stefanov, P.; Marinova, T.

    2000-01-01

    The structure and composition of chromium oxide films formed on stainless steel by immersion in a chromium electrolyte have been studied by SEM and XPS. Cr 2 O 3 crystallites in the range 30-150 nm are fully developed and cover the whole surface. The chemical composition in the depth and the thickness of the oxide layer have been determined by XPS sputter profiles. The oxide film can be described within the framework of a double layer consisting of a thin outer hydrated layer and an inner layer of Cr 2 O 3 . (orig.)

  18. Determination of gel content and SEM morphology for sago-PVA blends film

    International Nuclear Information System (INIS)

    Sarada Idris; Zulkafli Ghazali; Kamarudin Hashim

    2006-01-01

    Blends of polyvinyl alcohol and sago starch have been prepared to evaluate the potential of producing biodegradable products. Glycerol was introduced in the blends to improve the flexibility of the films as plasticizer in order more flexible film. These blends have been subjected to electron beam irradiation to evaluate and characterized radiation effect on the blends. Subsequently films were produced from this blend. The gel content of un-irradiated and irradiated films as evidence of cross linking was measured and discussed. This paper also discuss the films morphology from Scanning Electron Microscopy(SEM) observation. (Author)

  19. Red semántica de terremoto y maremoto en personas expuestas directa y vicariamente

    OpenAIRE

    Emilio Moyano Díaz; Katerinne Muñoz Tapia; Claudia Estrada; Marcelo Leiva-Bianchi

    2012-01-01

    Se busca identificar el significado de los conceptos 'terremoto' y 'maremoto' en dos grupos diferentemente expuestos al evento acaecido en Chile el 27/02/2010, en una muestra no probabilística intencional, compuesta por 240 personas provenientes de las ciudades de Constitución (n=104) - expuestas directamente al terremoto y maremoto -, y de Punta Arenas (n=136) expuestas vicariamente. Mediante redes semánticas naturales (R.S.) construidas ad-hoc, fue observado que terremoto y tsunami tienen s...

  20. Unveiling the Mysteries of Mars with a Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM)

    Science.gov (United States)

    Edmunson, J.; Gaskin, J. A.; Doloboff, I. J.; Jerman, G.

    2017-01-01

    Development of a miniaturized scanning electron microscope that will utilize the martian atmosphere to dissipate charge during analysis continues. This instrument is expected to be used on a future rover or lander to answer fundamental Mars science questions. To identify the most important questions, a survey was taken at the 47th Lunar and Planetary Science Conference (LPSC). From the gathered information initial topics were identified for a SEM on the martian surface. These priorities are identified and discussed below. Additionally, a concept of operations is provided with the goal of maximizing the science obtained with the minimum amount of communication with the instrument.

  1. Application of SEM/EDS to environmental geochemistry of heavy metals

    Directory of Open Access Journals (Sweden)

    Mateja Gosar

    2009-06-01

    Full Text Available Heavy metals represent a ubiquitous constituent of the near-surface environment, present in widely varyingconcentrations that typically have little impact on human behaviour and health. However, the mining of metals anduse of these metals in industrial processes has produced significant anthropogenic inputs of metals to both localand global environments. As such, a rigorous overview of the current accumulation of heavy metals and knowledgeof mineralogy of heavy metal-bearing phases is important for understanding their stability, solubility, mobility,bioavailability and toxicity. These data are of fundamental importance for environmental risk assessment and evaluationof future scenarios. Since conventional geochemical analyses provide limited information, other analyticalmethods have to be utilized for the characterisation of heavy metal-bearing phases. Significant analytical methodfor identification and characterisation of heavy metals in environmental media is a scanning electron microscopecoupled with energy dispersive X-ray spectrometer (SEM/EDS, an apparatus for qualitative and semi-quantitative chemical analysis at microne level, newly introduced to Geological Survey of Slovenia. Use of SEM/EDS was already introduced to environmental studies world-wide. In Slovenia, SEM/EDS analyses of environmental media werefirstly carried out on the Meža River stream sediments and snow deposits from Ljubljana urban area.Heavy metal-bearing phases in the Meža River stream sediments were apportioned to three source areas: Mežica mining/smelting area (geogenic-technogenic origin, Ravne ironworks area (technogenic origin and the Meža River catchment area (geogenic origin, which corresponds to data obtained by conventional geochemical and multivariate statistical methods. Airborne particles, identified in urban snow deposits, were interpreted as geogenic particles, represented by fragments of heavy metal-bearing minerals, and technogenic particles that

  2. Chemical Characterization of Bed Material Coatingsby LA-ICP-MS and SEM-EDS

    Science.gov (United States)

    Piispanen, M. H.; Mustonen, A. J.; Tiainen, M. S.; Laitinen, R. S.

    Bed material coatings and the consequent agglomeration of bed material are main ash-related problems in FB-boilers. The bed agglomeration is a particular problem when combusting biofuels and waste materials. Whereas SEM-EDS together with automated image processing has proven to be a convenient method to study compositional distribution in coating layers and agglomerates, it is a relatively expensive technique and is not necessarily widely available. In this contribution, we explore the suitability of LA-ICP-MS to provide analogous information of the bed.

  3. SEM Characterization of Extinguished Grains from Plasma-Ignited M30 Charges

    Science.gov (United States)

    Kinkennon, A.; Birk, A.; DelGuercio, M.; Kaste, P.; Lieb, R.; Newberry, J.; Pesce-Rodriguez, R.; Schroeder, M.

    2000-01-01

    M30 propellant grains that had been ignited in interrupted closed bomb experiments were characterize by scanning electron microscopy (SEM). Previous chemical analysis of extinguished grains had given no indications of plasma-propellant chemical interactions that could explain the increased burning rates that had been previously observed in full-pressure closed bomb experiments. (This does not mean that there is no unique chemistry occurring with plasma ignition. It may occur very early in the ignition event and then become obscured by the burning chemistry.) In this work, SEM was used to look at grain morphologies to determine if there were increases in the surface areas of the plasma-ignited grains which would contribute to the apparent increase in the burning rate. Charges were made using 30 propellant grains (approximately 32 grams) stacked in two tiers and in two concentric circles around a plastic straw. Each grain was notched so that, when the grains were expelled from the bomb during extinguishment, it could be determined in which tier and which circle each grain was originally packed. Charges were ignited in a closed bomb by either a nickel wire/Mylar-capillary plasma or black powder. The bomb contained a blowout disk that ruptured when the pressure reached 35 MPa, and the propellant was vented into a collection chamber packed with polyurethane foam. SEM analysis of the grains fired with a conventional black powder igniter showed no signs of unusual burning characteristics. The surfaces seemed to be evenly burned on the exteriors of the grains and in the perforations. Grains that had been subjected to plasma ignition, however, had pits, gouges, chasms, and cracks in the surfaces. The sides of the grains closest to the plasma had the greatest amount of damage, but even surfaces facing the outer wall of the bomb had small pits. The perforations contained gouges and abnormally burned regions (wormholes) that extended into the web. The SEM photos indicated that

  4. Recent Optical and SEM Characterization of Genesis Solar Wind Concentrator Diamond on Silicon Collector

    Science.gov (United States)

    Allton, Judith H.; Rodriquez, M. C.; Burkett, P. J.; Ross, D. K.; Gonzalez, C. P.; McNamara, K. M.

    2013-01-01

    One of the 4 Genesis solar wind concentrator collectors was a silicon substrate coated with diamond-like carbon (DLC) in which to capture solar wind. This material was designed for analysis of solar nitrogen and noble gases [1, 2]. This particular collector fractured during landing, but about 80% of the surface was recovered, including a large piece which was subdivided in 2012 [3, 4, 5]. The optical and SEM imaging and analysis described below supports the subdivision and allocation of the diamond-on-silicon (DOS) concentrator collector.

  5. Three-dimensional intracellular structure of a whole rice mesophyll cell observed with FIB-SEM.

    Science.gov (United States)

    Oi, Takao; Enomoto, Sakiko; Nakao, Tomoyo; Arai, Shigeo; Yamane, Koji; Taniguchi, Mitsutaka

    2017-07-01

    Ultrathin sections of rice leaf blades observed two-dimensionally using a transmission electron microscope (TEM) show that the chlorenchyma is composed of lobed mesophyll cells, with intricate cell boundaries, and lined with chloroplasts. The lobed cell shape and chloroplast positioning are believed to enhance the area available for the gas exchange surface for photosynthesis in rice leaves. However, a cell image revealing the three-dimensional (3-D) ultrastructure of rice mesophyll cells has not been visualized. In this study, a whole rice mesophyll cell was observed using a focused ion beam scanning electron microscope (FIB-SEM), which provides many serial sections automatically, rapidly and correctly, thereby enabling 3-D cell structure reconstruction. Rice leaf blades were fixed chemically using the method for conventional TEM observation, embedded in resin and subsequently set in the FIB-SEM chamber. Specimen blocks were sectioned transversely using the FIB, and block-face images were captured using the SEM. The sectioning and imaging were repeated overnight for 200-500 slices (each 50 nm thick). The resultant large-volume image stacks ( x = 25 μm, y = 25 μm, z = 10-25 μm) contained one or two whole mesophyll cells. The 3-D models of whole mesophyll cells were reconstructed using image processing software. The reconstructed cell models were discoid shaped with several lobes around the cell periphery. The cell shape increased the surface area, and the ratio of surface area to volume was twice that of a cylinder having the same volume. The chloroplasts occupied half the cell volume and spread as sheets along the cell lobes, covering most of the inner cell surface, with adjacent chloroplasts in close contact with each other. Cellular and sub-cellular ultrastructures of a whole mesophyll cell in a rice leaf blade are demonstrated three-dimensionally using a FIB-SEM. The 3-D models and numerical information support the hypothesis that rice mesophyll

  6. Validation of cell-free culture using scanning electron microscopy (SEM) and gene expression studies.

    Science.gov (United States)

    Yang, R; Elankumaran, Y; Hijjawi, N; Ryan, U

    2015-06-01

    A cell-free culture system for Cryptosporidium parvum was analysed using scanning electron microscopy (SEM) to characterise life cycle stages and compare gene expression in cell-free culture and cell culture using HCT-8 cells. Cryptosporidium parvum samples were harvested at 2 h, 8 h, 14 h, 26 h, 50 h, 74 h, 98 h, 122 h and 170 h, chemically fixed and specimens were observed using a Zeiss 1555 scanning electron microscope. The presence of sporozoites, trophozoites and type I merozoites were identified by SEM. Gene expression in cell culture and cell-free culture was studied using reverse transcriptase quantitative PCR (RT-qPCR) of the sporozoite surface antigen protein (cp15), the glycoprotein 900 (gp900), the Cryptosporidium oocyst wall protein (COWP) and 18S ribosomal RNA (rRNA) genes in both cell free and conventional cell culture. In cell culture, cp15 expression peaked at 74 h, gp900 expression peaked at 74 h and 98 h and COWP expression peaked at 50 h. In cell-free culture, CP15 expression peaked at 98 h, gp900 expression peaked at 74 h and COWP expression peaked at 122 h. The present study is the first to compare gene expression of C. parvum in cell culture and cell-free culture and to characterise life cycle stages of C. parvum in cell-free culture using SEM. Findings from this study showed that gene expression patterns in cell culture and cell-free culture were similar but in cell-free culture, gene expression was delayed for CP15 and COWP in cell free culture compared with the cell culture system and was lower. Although three life cycle stageswere conclusively identified, improvements in SEM methodology should lead to the detection of more life cycle stages. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Fast three-dimensional nanoscale metrology in dual-beam FIB-SEM instrumentation

    International Nuclear Information System (INIS)

    Repetto, Luca; Buzio, Renato; Denurchis, Carlo; Firpo, Giuseppe; Piano, Emanuele; Valbusa, Ugo

    2009-01-01

    A quantitative surface reconstruction technique has been developed for the geometric characterization of three-dimensional structures by using a combined focused ion beam-scanning electron microscopy (FIB-SEM) instrument. A regular pattern of lines is milled at normal incidence on the sample to be characterized and an image is acquired at a large tilt angle. By analyzing the pattern under the tilted view, a quantitative estimation of surface heights is obtained. The technique has been applied to a test sample and nanoscale resolution has been achieved. The reported results are validated by a comparison with atomic force microscopy measurements.

  8. Morphological and Production Changes in Planktonic and Biofilm Cells Monitored Using SEM and Raman Spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Hrubanová, Kamila; Krzyžánek, Vladislav; Samek, Ota; Skoupý, Radim; Šiler, Martin; Ježek, Jan; Obruča, S.; Zemánek, Pavel

    2017-01-01

    Roč. 23, S1 (2017), s. 1158-1159 ISSN 1431-9276 R&D Projects: GA ČR(CZ) GA15-20645S; GA ČR(CZ) GA16-12477S; GA ČR(CZ) GA17-15451S; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : biofilm cells * SEM * Raman spectroscopy Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering OBOR OECD: Electrical and electronic engineering Impact factor: 1.891, year: 2016

  9. An evaluation testing technique of single event effect using Beam Blanking SEM

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, J; Hada, T; Pesce, A; Akutsu, T; Matsuda, S [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Igarashi, T; Baba, S

    1997-03-01

    Beam Blanking SEM (Scanning Electron Microscope) testing technique has been applied to CMOS SRAM devices to evaluate the occurence of soft errors on memory cells. Cross-section versus beam current and LET curves derived from BBSEM and heavy ion testing technique, respectively, have been compared. A linear relation between BBSEM current and heavy ion LET has been found. The purpose of this study was to demonstrate that the application of focused pulsed electron beam could be a reliable, convenient and inexpensive tool to investigate the effects of heavy ions and high energy particles on memory devices for space application. (author)

  10. Roteamento em redes em malha sem fio com balanceamento de carga e caminhos mais curtos

    OpenAIRE

    Mello, Micael Oliveira Massula Carvalho de

    2014-01-01

    Redes em Malha Sem Fio - Wireless Mesh Networks (WMNs) são infraestruturas com propriedades autonômicas, como auto-organização e autorrecuperação, que podem ser implementadas com tecnologias amplamente disponíveis e de custo acessível. Além de suas aplicações atuais, como redes comunitárias e redes de acesso à Internet, as WMNs podem auxiliar na comunicação de Internet das Coisas e constituir infraestruturas robustas para redes inteligentes de energia, dentre outros usos. No en...

  11. Potenciais evocados auditivos de músicos com e sem ouvido absoluto

    OpenAIRE

    Oliveira, Letícia Ribeiro de

    2014-01-01

    Orientador: Prof. Dr. Francisco José Fraga da Silva Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia da Informação, 2014. Entende-se por ouvido absoluto a capacidade de produzir e/ou identificar e dar nome à frequência de qualquer nota musical sem a necessidade de uma referência externa. O estudo do ouvido absoluto pode ser uma oportunidade única para se investigar as interações entre informações linguísticas e não-linguísticas na memória de ...

  12. Resolving Differences in Absolute Irradiance Measurements Between the SOHO/CELIAS/SEM and the SDO/EVE.

    Science.gov (United States)

    Wieman, S R; Didkovsky, L V; Judge, D L

    The Solar EUV Monitor (SEM) onboard SOHO has measured absolute extreme ultraviolet (EUV) and soft X-ray solar irradiance nearly continuously since January 1996. The EUV Variability Experiment (EVE) on SDO, in operation since April of 2010, measures solar irradiance in a wide spectral range that encompasses the band passes (26 - 34 nm and 0.1 - 50 nm) measured by SOHO/SEM. However, throughout the mission overlap, irradiance values from these two instruments have differed by more than the combined stated uncertainties of the measurements. In an effort to identify the sources of these differences and eliminate them, we investigate in this work the effect of reprocessing the SEM data using a more accurate SEM response function (obtained from synchrotron measurements with a SEM sounding-rocket clone instrument taken after SOHO was already in orbit) and time-dependent, measured solar spectral distributions - i.e ., solar reference spectra that were unavailable prior to the launch of the SDO. We find that recalculating the SEM data with these improved parameters reduces mean differences with the EVE measurements from about 20 % to less than 5 % in the 26 - 34 nm band, and from about 35 % to about 15 % for irradiances in the 0.1 - 7 nm band extracted from the SEM 0.1 - 50 nm channel.

  13. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    Science.gov (United States)

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  14. Automated transmission-mode scanning electron microscopy (tSEM for large volume analysis at nanoscale resolution.

    Directory of Open Access Journals (Sweden)

    Masaaki Kuwajima

    Full Text Available Transmission-mode scanning electron microscopy (tSEM on a field emission SEM platform was developed for efficient and cost-effective imaging of circuit-scale volumes from brain at nanoscale resolution. Image area was maximized while optimizing the resolution and dynamic range necessary for discriminating key subcellular structures, such as small axonal, dendritic and glial processes, synapses, smooth endoplasmic reticulum, vesicles, microtubules, polyribosomes, and endosomes which are critical for neuronal function. Individual image fields from the tSEM system were up to 4,295 µm(2 (65.54 µm per side at 2 nm pixel size, contrasting with image fields from a modern transmission electron microscope (TEM system, which were only 66.59 µm(2 (8.160 µm per side at the same pixel size. The tSEM produced outstanding images and had reduced distortion and drift relative to TEM. Automated stage and scan control in tSEM easily provided unattended serial section imaging and montaging. Lens and scan properties on both TEM and SEM platforms revealed no significant nonlinear distortions within a central field of ∼100 µm(2 and produced near-perfect image registration across serial sections using the computational elastic alignment tool in Fiji/TrakEM2 software, and reliable geometric measurements from RECONSTRUCT™ or Fiji/TrakEM2 software. Axial resolution limits the analysis of small structures contained within a section (∼45 nm. Since this new tSEM is non-destructive, objects within a section can be explored at finer axial resolution in TEM tomography with current methods. Future development of tSEM tomography promises thinner axial resolution producing nearly isotropic voxels and should provide within-section analyses of structures without changing platforms. Brain was the test system given our interest in synaptic connectivity and plasticity; however, the new tSEM system is readily applicable to other biological systems.

  15. Proteinose alveolar pulmonar Aspectos na tomografia computadorizada de alta resolução** Trabalho realizado nos Departamentos ou Serviços de Radiologia da Universidade Federal Fluminense (UFF - RJ; Hospital Universitário Clementino Fraga Filho - RJ; Faculdade de Medicina de São José do Rio Preto (FAMERP -SP; Universidade de Campinas (UNICAMP - SP; Pavilhão Pereira Filho - RS, e Universidade Federal de Santa Catarina - SC.

    Directory of Open Access Journals (Sweden)

    Erick Malheiro Leôncio Martins

    2002-07-01

    Full Text Available RESUMO: A proteinose alveolar pulmonar é uma doença rara cuja etiologia ainda permanece desconhecida. É caracterizada pelo preenchimento alveolar por um material proteináceo que determina um quadro pulmonar restritivo com hipoxemia e várias alterações radiológicas. Neste trabalho são analisadas e discutidas as alterações encontradas nas tomografias computadorizadas de alta resolução de doze pacientes com proteinose alveolar pulmonar. Seis casos eram da forma primária da doença, e os outros seis da secundária, estando associados à silicose, asbestose, leucemia, síndrome da imunodeficiência adquirida e lúpus eritematoso sistémico. O objectivo básico foi estudar as alterações tomográficas mais frequentes. Na maioria dos casos, os aspectos tomográficos foram correlacionados com os dados anatomopatológicos, provenientes de biópsias cirúrgicas ou necropsia. Os aspectos tomográficos mais frequentes foram as opacidades em vidro fosco, com distribuição geográfica, associadas a espessamento liso dos septos interlobulares, resultando no padrão de pavimentação em mosaico. Estas alterações foram encontradas em todos os pacientes com a forma primária, não predominando em nenhuma região pulmonar específica. Na forma secundária, cinco dos seis casos apresentavam alterações tomográficas não observadas na forma primária da doença como, por exemplo, placas pleurais, derrame pleural, nódulos centrolobulares, linfonodomegalias e padrão de vidro fosco sem associação com espessamento de septos interlobulares. Além disto, em três destes casos houve um predomínio das lesões nas regiões póstero-inferiores dos pulmões.REV PORT PNEUMOL 2002; VIII(4: 303-314 ABSTRACT: Pulmonary alveolar proteinosis is a rare condition and it’s etiology remains unknown. It is characterized by the accumulation

  16. The Effect of Different Cleaning Protocols on Post Space: A SEM Study

    Directory of Open Access Journals (Sweden)

    Giuseppe Lo Giudice

    2016-01-01

    Full Text Available Aim. Purpose of the present paper is to analyze the efficiency of different post-space irrigation protocols. Methods. 28 single rooted teeth were endodontically treated. After post-space preparation every sample was assigned to one of three experimental groups and to one control group. In each group different irrigation protocols were performed as follows: EDTA (Group A, 37% orthophosphoric acid (Group B, and EDTA + 37% orthophosphoric acid with ultrasounds activation (Group C. In the control group (Group D the irrigate association was not activated by ultrasounds. Three zones (coronal, middle, and apical of each sample were analyzed by using Scan Electron Microscopy (SEM without any metallization procedures. The presence of smear layer on the canal surface was qualitatively evaluated by applying Serafino’s score with values included between 0 and 2. Results. The results of the research showed how Group C recorded the better results (0.81±0.72. Group A and Group B showed lower mean scores (1.06±0.69 and 1.08±0.77; Group D showed the lowest mean score of 1.30±0.69. The SEM observation analysis demonstrated how the smear layer presence decreased in the crown-apical direction. Conclusions. The different post-space treatments statistically determine significant differences on the dentinal surfaces cleansing. The absence of ultrasonic activation lowers the cleansing efficacy of endocanalar irrigants, showing sensible differences among each post-space zone.

  17. Improvement in the Characterization of the 2099 Al-Li Alloy by FE-SEM

    Science.gov (United States)

    Brodusch, Nicolas; Trudeau, Michel L.; Michaud, Pierre; Brochu, Mathieu; Rodrigue, Lisa; Boselli, Julien; Gauvin, Raynald

    This paper describes how state-of-the-art Field-Emission Scanning Electron Microscopy (FE-SEM) can contribute to the characterization of the 2099 aluminum-lithium alloy, and metallic alloys in general. Investigations were carried out on bulk and thinned samples. BSE imaging at 3kV and STEM imaging at 30kV along with highly efficient microanalysis permitted to correlate experimental and expected structures. Although our results confirm previous studies, this work points out possible substitutions of Mg and Zn with Li, Al and Cu in the T1 precipitates. Zinc and magnesium are also present in "rice grain" shaped precipitates at the grain boundaries. The versatility of the FE-SEM is highlighted in that it can provide information at the macro and micro scales with relevant details. Its ability to probe the distribution of precipitates from nano-to micro-sizes throughout the matrix makes Field-Emission Scanning Electron Microscopy a suitable technique for the characterization of metallic alloys.

  18. Marginal adaptation of newer root canal sealers to dentin: A SEM study.

    Science.gov (United States)

    Polineni, Swapnika; Bolla, Nagesh; Mandava, Pragna; Vemuri, Sayesh; Mallela, Madhusudana; Gandham, Vijaya Madhuri

    2016-01-01

    This in vitro study evaluated and compared the marginal adaptation of three newer root canal sealers to root dentin. Thirty freshly extracted human single-rooted teeth with completely formed apices were taken. Teeth were decoronated, and root canals were instrumented. The specimens were randomly divided into three groups (n = 10) based upon the sealer used. Group 1 - teeth were obturated with epoxy resin sealer (MM-Seal). Group 2 - teeth were obturated with mineral trioxide aggregate (MTA) based sealer (MTA Fillapex), Group 3 - teeth were obturated with bioceramic sealer (EndoSequence BC sealer). Later samples were vertically sectioned using hard tissue microtome and marginal adaptation of sealers to root dentin was evaluated under coronal and apical halves using scanning electron microscopy (SEM) and marginal gap values were recorded. The data were statistically analyzed by two-way ANOVA and Tukey's multiple post hoc test. The highest marginal gap was seen in Group 2 (apical-16680.00 nm, coronal-10796 nm) and the lowest marginal gap was observed in Group 1 (apical-599.42 nm, coronal-522.72 nm). Coronal halves showed superior adaptation compared to apical halves in all the groups under SEM. Within the limitations of this study epoxy resin-based MM-Seal showed good marginal adaptation than other materials tested.

  19. Analyzing the scale of the bainitic ferrite plates by XRD, SEM and TEM

    International Nuclear Information System (INIS)

    Garcia-Mateo, Carlos; Jimenez, Jose A.; Lopez-Ezquerra, Belen; Rementeria, Rosalia; Morales-Rivas, Lucia; Kuntz, Matthias; Caballero, Francisca G.

    2016-01-01

    Since the major strengthening mechanisms in nanocrystalline bainitic steels arise from the exceptionally small size of the bainitc ferrite plate, accurate determination of this parameter is fundamental for quantitative relating the microstructure to the mechanical properties. In this work, the thickness of the bainitic ferrite subunits obtained by different bainitic heat treatments was determined in two steels, with carbon contents of 0.3 and 0.7 wt.%, from SEM and TEM micrographs. As these measurements were made on 2D images taken from random sections, the method includes some stereological correction factors to obtain accurate information. Finally, the determined thicknesses of bainitic ferrite plates were compared with the crystallite size calculated from the analysis of X-ray diffraction peak broadening. Although in some case the values obtained for crystallite size and plate thickness can be similar, this study confirms that indeed they are two different parameters. - Highlights: •Bainitic microstructure in a nanostructured and sub-micron steel •Bainitic ferrite plate thickness measured by SEM and TEM •Crystallite size determined by X-ray analysis

  20. Analyzing the scale of the bainitic ferrite plates by XRD, SEM and TEM

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Mateo, Carlos, E-mail: cgm@cenim.csic.es [Department of Physical Metallurgy, Spanish National Center for Metallurgical Research (CENIM-CSIC), Avda. Gregorio del Amo 8, E-28040 Madrid (Spain); Jimenez, Jose A.; Lopez-Ezquerra, Belen; Rementeria, Rosalia; Morales-Rivas, Lucia [Department of Physical Metallurgy, Spanish National Center for Metallurgical Research (CENIM-CSIC), Avda. Gregorio del Amo 8, E-28040 Madrid (Spain); Kuntz, Matthias [Robert-Bosch GmbH, Materials and Process Engineering Metals, Renningen, 70465 Stuttgart (Germany); Caballero, Francisca G. [Department of Physical Metallurgy, Spanish National Center for Metallurgical Research (CENIM-CSIC), Avda. Gregorio del Amo 8, E-28040 Madrid (Spain)

    2016-12-15

    Since the major strengthening mechanisms in nanocrystalline bainitic steels arise from the exceptionally small size of the bainitc ferrite plate, accurate determination of this parameter is fundamental for quantitative relating the microstructure to the mechanical properties. In this work, the thickness of the bainitic ferrite subunits obtained by different bainitic heat treatments was determined in two steels, with carbon contents of 0.3 and 0.7 wt.%, from SEM and TEM micrographs. As these measurements were made on 2D images taken from random sections, the method includes some stereological correction factors to obtain accurate information. Finally, the determined thicknesses of bainitic ferrite plates were compared with the crystallite size calculated from the analysis of X-ray diffraction peak broadening. Although in some case the values obtained for crystallite size and plate thickness can be similar, this study confirms that indeed they are two different parameters. - Highlights: •Bainitic microstructure in a nanostructured and sub-micron steel •Bainitic ferrite plate thickness measured by SEM and TEM •Crystallite size determined by X-ray analysis.

  1. Structure and surface morphology studies of cerium oxide system using XRD and SEM analysis

    International Nuclear Information System (INIS)

    Ahmad Jais Alimin; Farid Nasir Ani; Wan Azelee Wan Abu Bakar

    2000-01-01

    Conventional Precious Group Materials (PGM) catalyst systems have been using CeO 2 as an Oxygen Storage Capacity component in the catalyst washcoat. Due to the limitations of the PGM catalyst, researches are now focusing on improving or replacing this conventional system. In a previous work, the potential of a copper-ceria (Cu-Ce) oxide as a catalyst system has been identified. In this paper, the morphology and characterisation of Cu-Ce oxides analysed using XRD and SEM will be described. The Cu-Ce samples were prepared at a fixed ratio under temperatures of 400 o C and 800 o C. XRD diffractograms showed CeO 2 is in a cubic phase at 400 o C and 800 o C. At 800 o C, the CuO particle is visible, presumably has incorporated with the lattice structure of ceria, indicating an absent of solid state condition between copper and ceria. Analysis by SEM revealed significant increase in particle sizes with increasing calcination temperatures. (Author)

  2. Continuous observation of cavity growth and coalescence by creep-fatigue tests in SEM

    International Nuclear Information System (INIS)

    Arai, Masayuki; Ogata, Takashi; Nitta, Akito

    1995-01-01

    Structural components operating at high temperatures in power plants are subjected to interaction of thermal fatigue and creep which results in creep-fatigue damage. In evaluating the life of those components, it is important to understand microscopic damage evolution under creep-fatigue conditions. In this study, static creep and creep-fatigue tests with tensile holdtime were conducted on SUS304 stainless steel by using a high-temperature fatigue machine combined with a scanning electron microscope (SEM), and cavity growth and coalescence behaviors on surface grain boundaries were observed continuously by the SEM. Quantitative analysis of creep cavity growth based on the observation was made for comparison with theoretical growth models. As a result, it was found that grain boundary cavities nucleate at random and grow preferentially on grain boundaries in a direction almost normal to the stress axis. Under the creep condition, the cavities grow monotonously on grain boundaries while they remain the elliptical shape. On the other hand, under the creep-fatigue condition the cavities grow with an effect of local strain distribution around the grain boundary due to cyclic loading and the micro cracks of one grain-boundary length were formed by coalescence of the cavities. Also, cavity nucleation and growth rates for creep-fatigue were more rapid than those for static creep and the constrained cavity growth model coincided well with the experimental data for creep. (author)

  3. Replica of human dentin treated with different desensitizing agents: a methodological SEM study in vitro

    Directory of Open Access Journals (Sweden)

    Pereira Jose Carlos

    2002-01-01

    Full Text Available This is a preliminary study to determine a methodological sequence in vitro which may allow the reproduction of dentin for SEM analysis, after the use of different desensitizing agents. Dentin discs obtained from extracted human third molars were etched with 6% citric acid, an artificial smear layer was created and the surface dentin discs were divided into four quadrants. Quadrants 2, 3 and 4 of each disc were conditioned with 6% citric acid. The desensitizing agents (Oxa-Gel®, Gluma Desensitizer and an experimental agent were applied to quadrants 3 and 4. To evaluate the acid resistance of the treatment, quadrant 4 was etched again with 6% citric acid. An impression was then taken with Aquasil ULV. After a setting period of 6 min, each disc was removed from the impression and stored in a moist-free environment for 24 h at 37ºC. After that time, a low-viscosity epoxy resin (Araltec GY 1109 BR was poured into the impression and cured for 24 h. All specimens were metal-coated for SEM analysis. Comparison of the photomicrographs of dentin discs with their respective impressions and resin replicas showed that this technique can reproduce the characteristics of the dentin surface treated with desensitizing agents.

  4. Morphological, chemical and structural characterisation of deciduous enamel: SEM, EDS, XRD, FTIR and XPS analysis.

    Science.gov (United States)

    Zamudio-Ortega, C M; Contreras-Bulnes, R; Scougall-Vilchis, R J; Morales-Luckie, R A; Olea-Mejía, O F; Rodríguez-Vilchis, L E

    2014-09-01

    The purpose of this study was to characterise the enamel surface of sound deciduous teeth in terms of morphology, chemical composition, structure and crystalline phases. The enamel of 30 human deciduous teeth was examined by: Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Spectroscopy (EDS), X-ray Powder Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), and X-ray Photoelectron Spectroscopy (XPS). Chemical differences between incisors and canines were statistically evaluated using the Mann-Whitney U test (p ≤ 0.05). Three enamel patterns were observed by SEM: 'mostly smooth with some groves', 'abundant microporosities' and 'exposed prisms'. The average Ca/P molar ratios were 1.37 and 1.03 by EDS and XPS, respectively. The crystallite size determined by XRD was 210.82 ± 16.78 Å. The mean ratio between Ca bonded to phosphate and Ca bonded to hydroxyl was approximately 10:1. The enamel of sound deciduous teeth showed two main patterns: 'mostly smooth with some groves' and 'abundant microporosities'. 'Exposed prisms' was a secondary pattern. There were slight variations among the Ca/P molar ratios found by EDS and XPS, suggesting differences in the mineral content from the enamel surface to the interior. The crystalline phases found in enamel were hydroxyapatite and carbonate apatite, with major type B than type A carbonate incorporation.

  5. MULTIMODALIDADE E A CONSTRUÇÃO DA IDENTIDADE DO SEM-TERRA

    Directory of Open Access Journals (Sweden)

    Vanderleiidalice J. Zacchi

    2009-12-01

    Full Text Available RESUMO: O objetivo deste trabalho é analisar a maneira como o movimento dos Trabalhadores Rurais Sem Terra (mST utiliza os diferentesmodos de produçãode significado e como, nesse processo, é construída sua identidade. A análise será efetuada principalmente a partir de textos impressos, digitais e eletrônicos produzidos pelos sem-terra. Apesar de fazer bom uso das diversas habilidades pressupostas na multimodalidade, o movimento ainda se apoia fortemente no modo linguístico tanto na autorrepresentação quanto na ação social. PALAVRAS-CHAVE: multiletramento, mST, identidade, Internet, mídia. ABSTRACT: This paper aims at analysing the identity construction of the Landless Rural Workers movement (mST by making use of different modes of meaning-construction. The data provided for analysis are based especially on printed, electronic, and digital texts produced by the movement. Although the mST uses multimodal texts extensively, it still relies heavily on the linguistic mode when engaging in both self-representation and social action. KEYWORDS: multiliteracies, landless movement, identity, Internet, media.

  6. Microstructure investigations of Ba-Sr mixed ferrites, using SEM technique

    International Nuclear Information System (INIS)

    Amighian, J.; Mozaffari, M.

    1996-01-01

    A series of isotropic Ba-Sr mixed ferrites were prepared, using a conventional dry technique. The starting materials were hematite by product of Isfahan steel factory, strontium carbonate from Merck company and barium carbonate obtained from local source. The principle phase of the samples was chosen to have a composition in the form of (BaO) sub 1-x (SrO) sub x nFe sub 2 O sub 3, in which x varied between 0 to l and n was varied between 5 to 6. The raw materials were thoroughly mixed and fired in an electrical furnace for 2 hours. They were then milled in an vibrating ball mill, in which the optimum milling time for each sample was obtained. After annealing at 750 degree C, the powders were compacted in a cylindrical die under 5 tons/cm sup 2. The compacts were then mixed with a binder and sintered in air for 10 minutes at their optimum temperatures. Using SEM technique, the microstructure of the samples were investigated. Using a permeameter, the coercive force Hc and remanent induction Br were measured. The microstructures obtained from SEM technique can be used to control the sintering stage in ferrite fabrication

  7. Observation particle morphology of colloidal system by conventional SEM with an improved specimen preparation technique.

    Science.gov (United States)

    Xu, Jing; Hou, Zhaosheng; Yuan, Xiaojiao; Guo, Hong

    2011-08-01

    On the basis of our previous report that polymer emulsion with different viscosity can be investigated by conventional scanning electron microscopy (SEM), we have developed an improved specimen preparation technique for obtaining particle morphology and size of colloidal silver, collagen, glutin, and polymer microspheres. In this study, we expect to provide a means for charactering the three-dimensional surface microstructure of colloidal particles. Dilution of the samples with appropriate volatile solvent like ethanol is effective for SEM specimen preparation. At a proper ratio between sample and ethanol, the colloidal particles are dispersed uniformly in ethanol and then deposited evenly on the substrate. Different drying methods are studied to search a proper drying condition, in which the small molecule solvent is removed without destroying the natural particle morphology. And the effects of ethanol in the specimen preparation process are described by analyzing the physicochemical properties of ethanol. The specimen preparation technique is simple and can be achieved in common laboratory for charactering the particle morphology of colloidal system. Copyright © 2010 Wiley-Liss, Inc.

  8. Non-oxidative and oxidative torrefaction characterization and SEM observations of fibrous and ligneous biomass

    International Nuclear Information System (INIS)

    Chen, Wei-Hsin; Lu, Ke-Miao; Lee, Wen-Jhy; Liu, Shih-Hsien; Lin, Ta-Chang

    2014-01-01

    Highlights: • Non-oxidative and oxidative torrefaction of biomass is studied. • Two fibrous biomasses and two ligneous biomasses are tested. • SEM observations of four biomasses are provided. • Fibrous biomass is more sensitive to O 2 concentration than ligneous biomass. • The performance of non-oxidative torrefaction is better than that of oxidative torrefaction. - Abstract: Oxidative torrefaction is a method to reduce the operating cost of upgrading biomass. To understand the potential of oxidative torrefaction and its impact on the internal structure of biomass, non-oxidative and oxidative torrefaction of two fibrous biomass materials (oil palm fiber and coconut fiber) and two ligneous ones (eucalyptus and Cryptomeria japonica) at 300 °C for 1 h are studied and compared with each other. Scanning electron microscope (SEM) observations are also performed to explore the impact of torrefaction atmosphere on the lignocellulosic structure of biomass. The results indicate that the fibrous biomass is more sensitive to O 2 concentration than the ligneous biomass. In oxidative torrefaction, an increase in O 2 concentration decreases the solid yield. The energy yield is linearly proportional to the solid yield, which is opposite to the behavior of non-oxidative torrefaction. The performance of non-oxidative torrefaction is better than that of oxidative torrefaction. As a whole, ligneous biomass can be torrefied in oxidative environments at lower O 2 concentrations, whereas fibrous biomass is more suitable for non-oxidative torrefaction

  9. SEM-EDS Observation of Structure Changes in Synthetic Zeolites Modified for CO2 Capture Needs

    Science.gov (United States)

    Wdowin, Magdalena; Panek, Rafal; Franus, Wojciech

    Carbon dioxide is the main greenhouse gas and its amount still increase in the atmosphere. Air pollution and greenhouse effect caused by CO2 emission have become a major threat to the environment on a global scale. Carbon dioxide sequestration (i.e. capture and consequently geological storage) is the key strategy within the portfolio of actions to reduce CO2 emission to the atmosphere. The most costly stage is capture of CO2, therefore there is a need to search new solutions of this technology. For this purpose it was examined Na-X synthetic zeolites, that were silver and PEI (polyethyleneimine) activated. SEM-EDS investigation enable to find a changes in structure of this materials after treatment. Where, as a result of silver activation from EDS analysis it is seen that Ag occur in Na-X structure, what indicate a substitution of Ag2+ for Na+ ions in crystal lattice. Analysing wt% the EDS analysis has shown that zeolite Na-X after silver impregnation becomes Ag-X zeolite. For Na-X-PEI activated it is observed a distinct organic compound in the form of coatings on Na-X crystals causing a sealing of pores in tested zeolite. Further examination of these materials concern determination of surface properties and experiments of CO2 sorption. But SEM-EDS analysis enable to determine the extent of activation, what is very important in determination of optimal conditions for such treatment in order to obtain better sorbent of CO2.

  10. Using BIB-SEM to determine pore morphology and pore size distributions in coal macerals

    Energy Technology Data Exchange (ETDEWEB)

    Giffin, S.; Littke, R. [RWTH Aachen Univ. (Germany). Inst. of Geology and Geochemistry of Petroleum and Coal; Klaver, J.; Urai, J.L. [RWTH Aachen Univ. (Germany). Structural Geology, Tectonics and Geomechanics

    2013-08-01

    The composition of coalbeds is considerably heterogeneous, affecting the transport pathways for fluids within the coal. Transport pathways include cleats and larger pores. However, only a few clues exist as the nature of these pores. This study examines the morphology and distribution of macro- and mesopores in coal samples, using broad ion beam (BIB) milling to prepare relief- and damage-free polished surfaces of coal samples for high-resolution SEM imaging. Broad ion beam milling is advantageous to focused ion beam milling in that a larger surface area can be milled. Combining that with SEM imaging results in a useful tool to study pore morphology and distributions in the size range between 10 nm and 10 {mu}m. Since BIB-sections of a few square millimeters are not large enough to be statistically representative, results cannot be easily interpreted from a coal seam standpoint. Therefore, porosity was investigated as a function of maceral type to characterize pore morphologies. Macerals from the vitrinite and inertinite groups were selected with a known relationship to bedding. BIB-sections were milled parallel to bedding and perpendicular to bedding, and the pores were evaluated in each section. The goal of this study is to (1) qualitatively describe pore morphology with respect to maceral type and (2) quantitatively characterize pore size distributions with respect to maceral and in relationship to bedding. Our results lead to a better understanding of bulk coal porosity due to the visual, spatial representation and quantification of pores in individual macerals. (orig.)

  11. Charging effects of PET under electron beam irradiation in a SEM

    International Nuclear Information System (INIS)

    Jbara, O; Rondot, S; Hadjadj, A; Patat, J M; Fakhfakh, S; Belhaj, M

    2008-01-01

    This paper deals with charge trapping and charge transport of polyethylene terephthalate (PET) polymer subjected to electron irradiation in a scanning electron microscope (SEM). Measurement of displacement current and leakage current using an arrangement adapted to the SEM allows the amount of trapped charge during and after electron irradiation to be determined and the charge mechanisms regulation to be studied. These mechanisms involve several parameters related to the electronic injection, the characteristics of insulator and the effects of the trapped charge itself. The dynamic trapping properties of PET samples are investigated and the time constants of charging are evaluated for various conditions of irradiation. The determination of the trapping cross section for electrons is possible by using the trapping rate at the onset of irradiation. Many physical processes are involved in the charging and discharging mechanisms; among them surface conduction is outlined. Through the control of irradiation conditions, various types of surface discharging (flashover phenomenon) behaviour are also observed. The strength of the electric field initiating surface discharge is estimated.

  12. Enhancing nanoscale SEM image segmentation and reconstruction with crystallographic orientation data and machine learning

    International Nuclear Information System (INIS)

    Converse, Matthew I.; Fullwood, David T.

    2013-01-01

    Current methods of image segmentation and reconstructions from scanning electron micrographs can be inadequate for resolving nanoscale gaps in composite materials (1–20 nm). Such information is critical to both accurate material characterizations and models of piezoresistive response. The current work proposes the use of crystallographic orientation data and machine learning for enhancing this process. It is first shown how a machine learning algorithm can be used to predict the connectivity of nanoscale grains in a Nickel nanostrand/epoxy composite. This results in 71.9% accuracy for a 2D algorithm and 62.4% accuracy in 3D. Finally, it is demonstrated how these algorithms can be used to predict the location of gaps between distinct nanostrands — gaps which would otherwise not be detected with the sole use of a scanning electron microscope. - Highlights: • A method is proposed for enhancing the segmentation/reconstruction of SEM images. • 3D crystallographic orientation data from a nickel nanocomposite is collected. • A machine learning algorithm is used to detect trends in adjacent grains. • This algorithm is then applied to predict likely regions of nanoscale gaps. • These gaps would otherwise be unresolved with the sole use of an SEM

  13. Effect of two bleaching agents on enamel morphology: a SEM study

    Directory of Open Access Journals (Sweden)

    Ghavam M.

    2005-05-01

    Full Text Available Statement of Problem: Bleaching materials are able to change the surface morphology as well as mineral and organic content of tooth structure. Considering that bleaching is done for aesthetic purpose, awareness of the possible effect of these materials on hard tissue is important, because it may affect the restorative treatments. Purpose: The aim of this study was comparing the effect of two bleaching materials, Kimia and Ultradent both containing 35% H2O2, on tooth enamel by SEM. Materials and Methods: Five intact central incisors were cut into three sections vertically and each part was randomly divided into three groups. Group 1 (control, without any bleaching. Group 2, bleached with Kimia 35% H2O2. Group 3, bleached with Ultradent 35% H2O2. Each tooth served as its own control. Then the samples were observed by SEM with 250 and 500 magnifications. Results: In the control group some scratches and small white grains were observed which seems to be the result of mastication trauma and pumice powder. In the other groups, morphologic changes like increased surface roughness, deepening of cracks, rod exposure and presence of new cracks were observed. The two experimental materials did not differ in these regards. Conclusion: It seems that both studied materials have limited destructive effects on tooth enamel which seems to be of no clinical importance.

  14. Tratamento da forma mucosa de leishmaniose sem resposta a glucantime, com anfotericina B liposomal

    Directory of Open Access Journals (Sweden)

    Raimunda Nonata Ribeiro Sampaio

    1997-04-01

    Full Text Available Tratamos com ambisome (2 a 5g totais de dose seis pacientes com leishmaniose mucosa sem resposta a tratamento com glucantime (20mg SbV/kg/dia. A dose diária usada foi 2 a 3mg/kg/dia, aplicada por um mínimo de 20 dias. Após 26 a 38 meses de acompanhamento, cinco pacientes estão clinicamente curados. Um recidivou aos 6 meses. Não foram observados efeitos colaterais além de cefaléia, após a injeção. O ambisome constitue uma opção terapêutica para os pacientes com leishmaniose mucosa sem resposta aos antimoniais.We treated six patients with mucosal leishmaniasis who failed to respond to glucantime (20mg/kg/day with ambisome (2-5 grams total dose. The daily dose was 2-3mg/kg/day given for a minimum of 20 days. After 26-38 months of follow up, five patients were clinically cured. One relapsed after six months. No side effects of therapy were observed apart from headache after injection. Ambisome is a therapeutic option for patients with mucosal leishmaniasis unresponsive to antimonials.

  15. SEM Evaluation of Internal Adaptation of Bases and Liners under Composite Restorations

    Directory of Open Access Journals (Sweden)

    Dimitrios Dionysopoulos

    2014-04-01

    Full Text Available The aim of this study was to evaluate the interfacial microgaps generating between different materials and between materials and dentin after polymerization of the composite restorations, using SEM. Methods: The materials investigated were a composite, an adhesive, a RMGI, and a calcium hydroxide. Thirty third molars were selected and two circular class V cavities (5 mm × 3 mm for each tooth were made. The teeth were randomly assigned into six groups and restored with a combination of the materials. The specimens were subjected to thermocycling and each tooth was sectioned mesiodistally in two halves. Each half was sectioned along the longitudinal axis through the center of the restorations to obtain a slice of 2 mm. The specimens were examined under SEM. The interfaces between the liners, the liners and dentin, and between the liners and the composite were examined for microgaps. Results: The results showed that there was not any significant difference in the mean width of microgaps in the interfaces between Dycal-dentin and Vitrebond-dentin (p>0.05. However, the width of microgaps in the interfaces between dentin-Clearfil Tri-S Bond was significantly smaller (p<0.05. The use of Clearfil Tri-S Bond reduced the possibility of microgap formation between the bonded interface and the materials tested.

  16. Mel de abelhas sem ferrão: proposta de regulamentação

    Directory of Open Access Journals (Sweden)

    Ricardo Costa Rodrigues de Camargo

    Full Text Available Resumo Os méis das abelhas sem ferrão são produtos únicos da biodiversidade brasileira, presentes e valorizados pela cultura popular desde os povos originais das Américas. Por ser mais ácido e apresentar maior teor de umidade, seu sabor é peculiar e sua viscosidade é menor quando comparada ao mel proveniente da espécie exótica Apis mellifera. Devido a essas diferenças, esse produto necessita do estabelecimento de parâmetros físico-químicos específicos que sejam referência tanto para controle de qualidade como para sua comercialização. Com base em pesquisas realizadas pela Embrapa, pelo Instituto de Tecnologia de Alimentos de Campinas e pelo levantamento bibliográfico de diversos estudos científicos realizados por outros institutos de ensino e pesquisa, esta comunicação tem como objetivo esclarecer as peculiaridades deste produto e apresentar uma proposta de Regulamento Técnico de Identidade e Padrão para o Mel das Abelhas Sem Ferrão, visando sua comercialização no Estado de São Paulo, contribuindo assim para a disponibilidade de um produto seguro e de qualidade para o consumidor final.

  17. Interpretation of secondary electron images obtained using a low vacuum SEM

    International Nuclear Information System (INIS)

    Toth, M.; Thiel, B.L.; Donald, A.M.

    2003-01-01

    Charging of insulators in a variable pressure environment was investigated in the context of secondary electron (SE) image formation. Sample charging and ionized gas molecules present in a low vacuum specimen chamber can give rise to SE image contrast. 'Charge-induced' SE contrast reflects lateral variations in the charge state of a sample caused by electron irradiation during and prior to image acquisition. This contrast corresponds to SE emission current alterations produced by sub-surface charge deposited by the electron beam. 'Ion-induced' contrast results from spatial inhomogeneities in the extent of SE signal inhibition caused by ions in the gaseous environment of a low vacuum scanning electron microscope (SEM). The inhomogeneities are caused by ion focusing onto regions of a sample that correspond to local minima in the magnitude of the surface potential (generated by sub-surface trapped charge), or topographic asperities. The two types of contrast exhibit characteristic dependencies on microscope operating parameters such as scan speed, beam current, gas pressure, detector bias and working distance. These dependencies, explained in terms of the behavior of the gaseous environment and sample charging, can serve as a basis for a correct interpretation of SE images obtained using a low vacuum SEM

  18. A practical approach to test the scope of FIB-SEM 3D reconstruction

    International Nuclear Information System (INIS)

    Ritter, M; Midgley, P A

    2010-01-01

    State-of-the-art focused ion beam (FIB) instruments have an ion column for sample modification and an electron column for scanning electron microscopy (SEM). 3D reconstruction of a sample volume can be achieved by serial sectioning using the FIB in combination with high-resolution SEM imaging of each cross-section. Usually, the resolution in the direction in which the sections are milled (z-direction) is much lower than in the plane of the cross-section (xy-direction) itself. Increased sampling in the z-direction can only be achieved by decreasing the distance between single sections. For a constant volume this is equivalent to increasing the number of sections, i.e. time and effort. To perform efficient 3D reconstructions the effect of the reduced sampling in the z-direction to the overall accuracy of the 3D reconstruction has to be known. We tested this approach with FIB conical test structures that were slice-and-view processed and subsequently reconstructed. Using a reference data set with a slice thickness (z-resolution) of 22 nm, data with z-resolutions ranging from 44 nm to 440 nm were created and reconstructed with commercial software. The calculated volumes for the simulated z-resolutions and their deviations from the reference volume are shown. Deviations of up to 35% occur and reach about 10% once the z-resolution was one fifth of the upper diameter of the conical structures.

  19. The innovation of cryo-SEM freeze-fracturing methodology demonstrated on high pressure frozen biofilm.

    Science.gov (United States)

    Hrubanova, Kamila; Nebesarova, Jana; Ruzicka, Filip; Krzyzanek, Vladislav

    2018-04-22

    In this study we present an innovative method for the preparation of fully hydrated samples of microbial biofilms of cultures Staphylococcus epidermidis, Candida parapsilosis and Candida albicans. Cryo-scanning electron microscopy (cryo-SEM) and high-pressure freezing (HPF) rank among cutting edge techniques in the electron microscopy of hydrated samples such as biofilms. However, the combination of these techniques is not always easily applicable. Therefore, we present a method of combining high-pressure freezing using EM PACT2 (Leica Microsystems), which fixes hydrated samples on small sapphire discs, with a high resolution SEM equipped with the widely used cryo-preparation system ALTO 2500 (Gatan). Using a holder developed in house, a freeze-fracturing technique was applied to image and investigate microbial cultures cultivated on the sapphire discs. In our experiments, we focused on the ultrastructure of the extracellular matrix produced during cultivation and the relationships among microbial cells in the biofilm. The main goal of our investigations was the detailed visualization of areas of the biofilm where the microbial cells adhere to the substrate/surface. We show the feasibility of this technique, which is clearly demonstrated in experiments with various freeze-etching times. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Multi-scale characterization by FIB-SEM/TEM/3DAP.

    Science.gov (United States)

    Ohkubo, T; Sepehri-Amin, H; Sasaki, T T; Hono, K

    2014-11-01

    In order to improve properties of functional materials, it is important to understand the relation between the structure and the properties since the structure has large effect to the properties. This can be done by using multi-scale microstructure analysis from macro-scale to nano and atomic scale. Scanning electron microscope (SEM) equipped with focused ion beam (FIB), transmission electron microscope (TEM) and 3D atom probe (3DAP) are complementary analysis tools making it possible to know the structure and the chemistry from micron to atomic resolution. SEM gives us overall microstructural and chemical information by various kinds of detectors such as secondary electron, backscattered electron, EDS and EBSD detectors. Also, it is possible to analyze 3D structure and chemistry via FIB serial sectioning. In addition, using TEM we can focus on desired region to get more complementary information from HRTEM/STEM/Lorentz images, SAED/NBD patterns and EDS/EELS to see the detail micro or nano-structure and chemistry. Especially, combination of probe Cs corrector and split EDS detectors with large detector size enable us to analyze the atomic scale elemental distribution. Furthermore, if the specimen has a complicated 3D nanostructure, or we need to analyze light elements such as hydrogen, lithium or boron, 3DAP can be used as the only technique which can visualize and analyze distribution of all constituent atoms of our materials within a few hundreds nm area. Hence, site-specific sample preparation using FIB/SEM is necessary to get desired information from region of interest. Therefore, this complementary analysis combination works very well to understand the detail of materials.In this presentation, we will show the analysis results obtained from some of functional materials by Carl Zeiss CrossBeam 1540EsB FIB/SEM, FEI Tecnai G(2) F30, Titan G2 80-200 TEMs and locally build laser assisted 3DAP. As the one of the example, result of multi-scale characterization for

  1. Site specific SEM/FIB/TEM for analysis of lubricated sliding wear of aluminium alloy composites

    International Nuclear Information System (INIS)

    Walker, J C; Jones, H; Rainforth, W M

    2006-01-01

    Although extensive research has been undertaken into the dry sliding wear of aluminium alloys, only limited work has been reported on lubricated wear. In this paper, the lubricated sliding wear of some powder derived aluminium alloy composites is reported. Stereo pairs of the worn surface were obtained in the SEM and digitally reconstructed to give an accurate projection of the surface topography. Analysis of the average surface roughness (R a ) along chosen sections provided quantitative information about the wear mechanism. Following this, dual beam focused ion beam (FIB) was undertaken to further explore the features revealed by the SEM surface reconstructions, with TEM sections removed from selected regions. Surface deformation was confined to a narrow layer, typically 1μm thick. Subgrain size within the subsurface layer was comparable to that found in dry sliding wear tests. Reinforcement fracture occurred in the surface particles only. The resultant fragments were often incorporated back into the surface following detachment, such that the total volume fraction reinforcement at the surface was greater than in the bulk. Thus, the dynamic surface topography was a result of three factors: surface deformation, local detachment of reinforcement and re-incorporation of the fragments back into the surface

  2. SEM and AFM studies of dip-coated CuO nanofilms.

    Science.gov (United States)

    Dhanasekaran, V; Mahalingam, T; Ganesan, V

    2013-01-01

    Cupric oxide (CuO) semiconducting thin films were prepared at various copper sulfate concentrations by dip coating. The copper sulfate concentration was varied to yield films of thicknesses in the range of 445-685 nm by surface profilometer. X-ray diffraction patterns revealed that the deposited films were polycrystalline in nature with monoclinic structure of (-111) plane. The surface morphology and topography of monoclinic-phase CuO thin films were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM), respectively. Surface roughness profile was plotted using WSxM software and the estimated surface roughness was about ∼19.4 nm at 30 mM molar concentration. The nanosheets shaped grains were observed by SEM and AFM studies. The stoichiometric compound formation was observed at 30 mM copper sulfate concentration prepared film by EDX. The indirect band gap energy of CuO films was increased from 1.08 to 1.20 eV with the increase of copper sulfate concentrations. Copyright © 2012 Wiley Periodicals, Inc.

  3. SEM analysis of enamel surface treated by Er:YAG laser: influence of irradiation distance.

    Science.gov (United States)

    Souza-Gabriel, A E; Chinelatti, M A; Borsatto, M C; Pécora, J D; Palma-Dibb, R G; Corona, S A M

    2008-07-01

    Depending on the distance of laser tip to dental surface a specific morphological pattern should be expected. However, there have been limited reports that correlate the Er:YAG irradiation distance with dental morphology. To assess the influence of Er:YAG laser irradiation distance on enamel morphology, by means of scanning electron microscopy (SEM). Sixty human third molars were employed to obtain discs (approximately =1 mm thick) that were randomly assigned to six groups (n=10). Five groups received Er:YAG laser irradiation (80 mJ/2 Hz) for 20 s, according to the irradiation distance: 11, 12, 14, 16, or 17 mm and the control group was treated with 37% phosphoric acid for 15 s. The laser-irradiated discs were bisected. One hemi-disc was separated for superficial analysis without subsequent acid etching, and the other one, received the phosphoric acid for 15 s. Samples were prepared for SEM. Laser irradiation at 11 and 12 mm provided an evident ablation of enamel, with evident fissures and some fused areas. At 14, 16 and 17 mm the superficial topography was flatter than in the other distances. The subsequent acid etching on the lased-surface partially removed the disorganized tissue. Er:YAG laser in defocused mode promoted slight morphological alterations and seems more suitable for enamel conditioning than focused irradiation. The application of phosphoric acid on lased-enamel surface, regardless of the irradiation distance, decreased the superficial irregularities.

  4. Modification of the microstructure of the films formed by gamma irradiated starch examined by SEM

    Science.gov (United States)

    Cieśla, K.; Sartowska, B.

    2016-01-01

    The paper concerns the effect of gamma irradiation carried out for starch on the microstructure of the films prepared using the starch and its composition with sodium laurate (NaLau) and cetyltrimethylammonium bromide (CTAB) studied by scanning electron microscopy (SEM). Potato starch was irradiated with 60Co gamma rays applying a dose of 30 kGy. Films were prepared by the solution casting method with the addition of 30 wt% glycerol as a plasticizer. Films containing NaLau and CTAB were prepared after performing the procedure, leading to starch-surfactant complexes. Mechanical tests and wetting angle measurements were performed for the films. SEM observations were carried out for the surfaces, fractures and/or sections of the films subjected to chemical fixation and for the dried films. The films obtained using irradiated starch are characterized by a smoother and more homogeneous structure as compared to those based on the non-irradiated starch. Besides, a number of small precipitates were observed on the films surfaces after drying and the number of those precipitates seemed to be higher after irradiation. The results can be related to differences in the microstructure of gels formed on the intermediate step of the films preparation and to the presence of two phases in the system and might serve for explanation of the radiation induced improvement of the hydrophilic/hydrophobic properties, a modification of the mechanical properties of the films, as well as for the changes of those properties resulting after storage.

  5. A two-step FEM-SEM approach for wave propagation analysis in cable structures

    Science.gov (United States)

    Zhang, Songhan; Shen, Ruili; Wang, Tao; De Roeck, Guido; Lombaert, Geert

    2018-02-01

    Vibration-based methods are among the most widely studied in structural health monitoring (SHM). It is well known, however, that the low-order modes, characterizing the global dynamic behaviour of structures, are relatively insensitive to local damage. Such local damage may be easier to detect by methods based on wave propagation which involve local high frequency behaviour. The present work considers the numerical analysis of wave propagation in cables. A two-step approach is proposed which allows taking into account the cable sag and the distribution of the axial forces in the wave propagation analysis. In the first step, the static deformation and internal forces are obtained by the finite element method (FEM), taking into account geometric nonlinear effects. In the second step, the results from the static analysis are used to define the initial state of the dynamic analysis which is performed by means of the spectral element method (SEM). The use of the SEM in the second step of the analysis allows for a significant reduction in computational costs as compared to a FE analysis. This methodology is first verified by means of a full FE analysis for a single stretched cable. Next, simulations are made to study the effects of damage in a single stretched cable and a cable-supported truss. The results of the simulations show how damage significantly affects the high frequency response, confirming the potential of wave propagation based methods for SHM.

  6. Protective effects of a zinc-hydroxyapatite toothpaste on enamel erosion: SEM study.

    Science.gov (United States)

    Colombo, Marco; Beltrami, Riccardo; Rattalino, Davide; Mirando, Maria; Chiesa, Marco; Poggio, Claudio

    2016-01-01

    The aim of the present in vitro study was to evaluate the protective effects of a zinc-hydroxyapatite toothpaste against an erosive challenge produced by a soft drink (Coca-Cola) using Scanning Electron Microscopy (SEM). Forty specimens were assigned to 4 groups of 10 specimens each (group 1: no erosive challenge, no toothpaste treatment, group 2: erosive challenge, no toothpaste treatment, group 3: erosive challenge, fluoride toothpaste treatment, group 4: erosive challenge, zinc-hydroxyapatite toothpaste treatment). The surface of each specimen was imaged by SEM. A visual rating system was used to evaluate the condition of the enamel surface; results were analyzed by nonparametric statistical methods. Statistically significant differences were found between the samples untreated and those immersed in Coca-Cola (group 1, 2); the highest grade of damage was found in group 2, while the lowest grade was recorded in the samples of group 4. Comparing the groups, the two analyzed toothpaste tended to protect in different extend. In this study treatment of erosively challenged enamel with Zn-Hap toothpaste showed a clear protective effect. This was greater than the effect observed for a normal fluoride toothpaste and confirmed the potential benefit the Zn-HAP technology can provide in protecting enamel from erosive acid challenges.

  7. To see or not to see: Imaging surfactant coated nano-particles using HIM and SEM

    International Nuclear Information System (INIS)

    Hlawacek, Gregor; Ahmad, Imtiaz; Smithers, Mark A.; Kooij, E. Stefan

    2013-01-01

    Nano-particles are of great interest in fundamental and applied research. However, their accurate visualization is often difficult and the interpretation of the obtained images can be complicated. We present a comparative scanning electron microscopy and helium ion microscopy study of cetyltrimethylammonium-bromide (CTAB) coated gold nano-rods. Using both methods we show how the gold core as well as the surrounding thin CTAB shell can selectively be visualized. This allows for a quantitative determination of the dimensions of the gold core or the CTAB shell. The obtained CTAB shell thickness of 1.0 nm–1.5 nm is in excellent agreement with earlier results using more demanding and reciprocal space techniques. - Author-Highlights: • CTAB coated gold nano-rods were imaged using high resolution imaging tools. • Selective imaging of either the gold core or CTAB shell is possible with HIM and SEM. • CTAB shell thickness measured using HIM and SEM agrees well with literature values

  8. La semántica del adjetivo y su representación mediante estructura de rasgos

    OpenAIRE

    Climent Roca, Salvador

    1995-01-01

    Por el trabajo que se describe se ha formulado un marco general de representación semántica de los adjetivos en una base de conocimiento léxica basada en estructuras de rasgos en la que operan la herencia y la unificación. Como principales aportaciones cabe destacar el propio diseño de un marco representativo suficientemente expresivo como para abarcar múltiples aspectos del significado del adjetivo, tales como orden superficial, restricciones selectivas, semántica léxica y semántica formal. ...

  9. 3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).

    Science.gov (United States)

    Drobne, Damjana

    2013-01-01

    Integration of a scanning electron microscope (SEM) and focused ion beam (FIB) technology into a single FIB/SEM system permits use of the FIB as a nano-scalpel to reveal site-specific subsurface microstructures which can be examined in great detail by SEM. The FIB/SEM technology is widely used in the semiconductor industry and material sciences, and recently its use in the life sciences has been initiated. Samples for FIB/SEM investigation can be either embedded in a plastic matrix, the traditional means of preparation of transmission electron microscopy (TEM) specimens, or simply dried as in samples prepared for SEM imaging. Currently, FIB/SEM is used in the life sciences for (a) preparation by the lift-out technique of lamella for TEM analysis, (b) tomography of samples embedded in a matrix, and (c) in situ site-specific FIB milling and SEM imaging using a wide range of magnifications. Site-specific milling and imaging has attracted wide interest as a technique in structural research of single eukaryotic and prokaryotic cells, small animals, and different animal tissue, but it still remains to be explored more thoroughly. In the past, preparation of samples for site-specific milling and imaging by FIB/SEM has typically adopted the embedding techniques used for TEM samples, and which have been very well described in the literature. Sample preparation protocols for the use of dried samples in FIB/SEM have been less well investigated. The aim of this chapter is to encourage application of FIB/SEM on dried biological samples. A detailed description of conventional dried sample preparation and FIB/SEM investigation of dried biological samples is presented. The important steps are described and illustrated, and direct comparison between embedded and dried samples of same tissues is provided. The ability to discover links between gross morphology of the tissue or organ, surface characteristics of any selected region, and intracellular structural details on the nanometer

  10. Sarcoma de Kaposi relacionado à síndrome da imunodeficiência adquirida: características do comprometimento hepático na tomografia computadorizada e na ressonância magnética Kaposi sarcoma related to acquired immunodeficiency syndrome: hepatic findings on computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Daniel Nobrega da Costa

    2008-04-01

    Full Text Available Sarcoma de Kaposi é uma neoplasia associada a condições de imunossupressão que acomete os vasos linfáticos e sanguíneos. É a neoplasia intra-hepática mais comum na síndrome da imunodeficiência adquirida. A tomografia computadorizada e a ressonância magnética revelam múltiplos pequenos nódulos, proeminência e realce dos planos periportais, devido à presença de tecido neoplásico. Os autores descrevem um caso de paciente masculino, de 47 anos de idade, com síndrome da imunodeficiência adquirida e sarcoma de Kaposi disseminado.Kaposi sarcoma is a neoplasm associated with immunosuppressive conditions, and involving blood and lymphatic vessels. It is the most frequent intrahepatic neoplasm in patients with acquired immunodeficiency syndrome. Computed tomography and magnetic resonance imaging demonstrate multiple small nodules, prominence and contrast-enhancement of periportal branches due to the presence of the neoplastic tissue. The authors report a case of a 47-year-old male patient with acquired immunodeficiency syndrome presenting disseminated Kaposi sarcoma.

  11. Complicações pulmonares após uso de crack: achados na tomografia computadorizada de alta resolução do tórax Pulmonary complications of crack cocaine use: high-resolution computed tomography of the chest

    Directory of Open Access Journals (Sweden)

    Alexandre Mançano

    2008-05-01

    Full Text Available Relatamos os achados na tomografia computadorizada de alta resolução de um paciente que, após uso de cocaína fumada (crack, desenvolveu quadro de hemoptise, dispnéia e dor torácica súbitas. As radiografias de tórax mostravam consolidações predominando em lobos superiores. A tomografia de alta resolução evidenciava opacidades em vidro fosco, consolidações e nódulos do espaço aéreo. Nova tomografia de controle, após suspensão da droga e uso de corticóides, mostrou regressão parcial das lesões e aparecimento de escavações. A correlação entre os achados clínicos, laboratoriais e de imagem permitiu o diagnóstico de "pulmão de crack".Here, we report high-resolution computed tomography (HRCT findings in a patient who developed sudden hemoptysis, dyspnea and chest pain after smoking crack cocaine. Chest X-rays showed consolidations, primarily in the upper lobes, and HRCT scans showed ground glass attenuation opacities, consolidations and air-space nodules. A follow-up CT, after drug use discontinuation and administration of corticosteroids, showed partial resolution of pulmonary lesions and the appearance of cavitations. Clinical, imaging and laboratory findings led to a diagnosis of 'crack lung'.

  12. Evaluating Neighborhoods Livability in Nigeria: A Structural Equation Modelling (SEM Approach

    Directory of Open Access Journals (Sweden)

    Sule Abass Iyanda

    2018-01-01

    Full Text Available There is a growing concern about city livability around the world and of particular concern is the aspects of the person-environment relationship which encompasses many characteristics suffice to make a place livable. Extant literature provides livability dimensions such as housing unit characteristics, neighborhood facilities, economic vitality and safety environment. These livability dimensions as well as their attributes found in the extant literature have been reported to have high reliability measurement level. Although, various methods have been applied to examine relationships among the variables however structural equation modeling (SEM has been found more holistic as a modeling technique to understand and explain the relationships that may exist among variable measurements. Structural equation modeling simultaneously performs multivariate analysis including multiple regression, path and factor analysis in the cause-effect relationships between latent constructs. Therefore, this study investigates the key factors of livability of planned residential neighborhoods in Minna, Nigeria with the research objectives of – (a to study the livability level of the selected residential neighborhoods, (b to determine the dimensions and indicators which most influence the level of livability in the selected residential neighborhoods, and (c to reliably test the efficacy of structural equation modeling (SEM in the assessment of livability. The methodology adopted in this study includes- Data collection with the aid of structured questionnaire survey administered to the residents of the study area based on stratified random sampling. The data collected was analyzed with the aid of the Statistical Package for Social Sciences (SPSS 22.0 and AMOS 22.0 software for structural equation modeling (a second-order factor. The study revealed that livability as a second-order factor is indicated by economic vitality, safety environment, neighborhood facilities

  13. Anastomose cavo-pulmonar total sem uso de material protético

    Directory of Open Access Journals (Sweden)

    Valdester C. PINTO Jr.

    1998-07-01

    Full Text Available Objetivo: Demonstrar a viabilidade na feitura de túnel cava inferior-cava superior com retalho da parede atrial direita, evitando o emprego de material protético. Casuística e Métodos: Foram operados 2 pacientes nos quais se empregou a técnica de anastomose cavo-pulmonar total, sem uso de material protético. O primeiro caso, A.L.M., masc, 4 anos, 15 kg, era portador de atresia tricúspide (EP, com comunicação interventricular (CIV restritiva. O segundo caso, M.E.N.O., fem, 15 anos, 47 kg, tinha doença de Ebstein. O controle pós-operatório dos pacientes foi feito com ecocardiograma e cateterismo cardíaco. As operações foram realizadas com o emprego de circulação extracorpórea (CEC, e cardioplegia sangüínea como método de proteção miocárdica. A canulação das cavas foi o mais distal possível. A tunelização foi realizada com retalho de tecido atrial direito, suturado ao septo interatrial, deixando-se o seio coronariano e a comunicação interatrial (CIA para a esquerda. Resultados: Ambos os pacientes evoluíram, sem complicações, na UTI. O primeiro apresentou derrame pleural discreto à direita, e o segundo mantém-se em estimulação artificial (VVI,R. Conclusões: A tunelização intra-atrial para anastomose cavo-pulmonar total pode ser realizada sem o uso de material protético, evitando-se os riscos advindos do seu emprego (calcificação, retração, embolização.The authors describe two cases (one tricuspid atresia without TGA or pulmonary stenosis, but with a restrictive IVC: the second of an Ebstein disease of total cavo-pulmonary anastomosis using only the tissue of the atrial wall, avoiding any prosthetic material. Both cases were done under cardiopulmonary bypass and cold blood cardioplegia. A flap of the right atrial wall was used to re-direct the blood flow. Pleural effusion in one patient and complete AV block in the other were the complications found. They conclude that right intra-atrial tunneling for

  14. Experimental investigation on the influence of instrument settings on pixel size and nonlinearity in SEM image formation

    DEFF Research Database (Denmark)

    Carli, Lorenzo; Genta, Gianfranco; Cantatore, Angela

    2010-01-01

    The work deals with an experimental investigation on the influence of three Scanning Electron Microscope (SEM) instrument settings, accelerating voltage, spot size and magnification, on the image formation process. Pixel size and nonlinearity were chosen as output parameters related to image...... quality and resolution. A silicon grating calibrated artifact was employed to investigate qualitatively and quantitatively, through a designed experiment approach, the parameters relevance. SEM magnification was found to account by far for the largest contribution on both parameters under consideration...

  15. Observation of interactions between hydrophilic ionic liquid and water on wet agar gels by FE-SEM and its mechanism

    International Nuclear Information System (INIS)

    Takahashi, Chisato; Shirai, Takashi; Fuji, Masayoshi

    2012-01-01

    Highlights: ► The mechanism of SEM observation of agar gel using ionic liquid was investigated. ► Weak hydrogen bond between ionic liquid and water exist even under vacuum condition. ► Ionic liquid binding ability with water is useful for observing wet material using FE-SEM. ► We could optimize the water concentrations of sample of IL and wet material mixtures. ► SEM observation of fine morphology of agar gel in optimum water content. - Abstract: In the present study, an attempt is made to understand the mechanism of field emission electron microscopy (FE-SEM) observation of wet agar gel using a typical hydrophilic ionic liquid (IL) 1-butyl-3-methylimidazolium tetrafluoroborate; [BMIM][BF 4 ]. The IL interaction with water molecules within agar gel during sample preparation condition for FE-SEM observation was investigated using Raman spectroscopy. Results showed that water molecules within agar gel form weak hydrogen bond such as BF 4 − ⋯HOH⋯BF 4 − by interaction with BF 4 − of IL, and, it remained stable even under vacuum condition at 60 °C, 24 h. This interaction was found to be helpful for IL displacement of the water molecules within agar gel. From this study, it was found that the exact morphology of gel materials in FE-SEM condition can be observed by optimization of water concentrations of IL and gel mixtures. Thus, using IL, agar gel or any other material under wet condition can be observed without drying in FE-SEM chamber, and, present result gives an insight to the mechanism of FE-SEM observation of agar gel using IL without any conducting coating.

  16. A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

    Science.gov (United States)

    Edmunson, J.; Gaskin, J. A.; Jerman, G. A.; Harvey, R. P.; Doloboff, I. J.; Neidholdt, E. L.

    2016-01-01

    The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

  17. Investigation of hidden periodic structures on SEM images of opal-like materials using FFT and IFFT.

    Science.gov (United States)

    Stephant, Nicolas; Rondeau, Benjamin; Gauthier, Jean-Pierre; Cody, Jason A; Fritsch, Emmanuel

    2014-01-01

    We have developed a method to use fast Fourier transformation (FFT) and inverse fast Fourier transformation (IFFT) to investigate hidden periodic structures on SEM images. We focused on samples of natural, play-of-color opals that diffract visible light and hence are periodically structured. Conventional sample preparation by hydrofluoric acid etch was not used; untreated, freshly broken surfaces were examined at low magnification relative to the expected period of the structural features, and, the SEM was adjusted to get a very high number of pixels in the images. These SEM images were treated by software to calculate autocorrelation, FFT, and IFFT. We present how we adjusted SEM acquisition parameters for best results. We first applied our procedure on an SEM image on which the structure was obvious. Then, we applied the same procedure on a sample that must contain a periodic structure because it diffracts visible light, but on which no structure was visible on the SEM image. In both cases, we obtained clearly periodic patterns that allowed measurements of structural parameters. We also investigated how the irregularly broken surface interfered with the periodic structure to produce additional periodicity. We tested the limits of our methodology with the help of simulated images. © 2014 Wiley Periodicals, Inc.

  18. Mapa de energia baseado em predição para redes de sensores sem fio

    OpenAIRE

    Raquel Aparecida de Freitas Mini

    2004-01-01

    O objetivo deste trabalho é construir o mapa de energia de uma rede de sensores sem fio utilizando técnicas de predição. Em mapas de energia baseados em predição, cada nó sensor utiliza algoritmos de predição para modelar sua dissipação de energia com o objetivo de prever seu consumo de energia no futuro. Nesta situação, ao invés de enviar para o nó sorvedouro apenas sua quantidade de energia disponível, cada sensor envia também os parâmetros do modelo que descreve seu consumo de energia. O n...

  19. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    International Nuclear Information System (INIS)

    Spyratou, E.; Asproudis, I.; Tsoutsi, D.; Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A.

    2010-01-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV (λ = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  20. The influence of different skin types on GSR sampling by tape lifting for SEM analysis.

    Science.gov (United States)

    Kara, İlker

    2017-12-01

    In this study, the change in the amounts the gunshot residues (GSR) collected by the "swab" method from shooter's right hand was analyzed using Scanning Electron Microscope-Energy Dispersive Spectroscopy (SEM-EDS) to test dependency on various conditions (such as skin color of the shooter, various physical properties, hair density of hands, size of the hands, sweaty or creamy (oiliness) hands). As a result of the analysis, there was no significant difference in the amount of GSR according to skin color, however, there was a change in the amount of GSR depending on the physical characteristics of the shooter. These results thought to have practical benefits for the experts performing GSR analysis using the swab technique to assess the incidence. © 2017 Wiley Periodicals, Inc.