WorldWideScience

Sample records for compression bandaging system

  1. A comparison of inferface pressures of three compression bandage systems.

    Science.gov (United States)

    Hanna, Richard; Bohbot, Serge; Connolly, Nicki

    To measure and compare the interface pressures achieved with two compression bandage systems - a four-layer system (4LB) and a two-layer short-stretch system (SSB) - with a new two-layer system (2LB), which uses an etalonnage (performance indicator) to help achieve the correct therapeutic pressure for healing venous leg ulcers - recommended as 40 mmHg. 32 nurses with experience of using compression bandages applied each of the three systems to a healthy female volunteer in a sitting position. The interface pressures and time taken to apply the systems were measured. A questionnaire regarding the concept of the new system and its application in comparison to the existing two systems was then completed by the nurses. The interface pressures achieved show that many nurses applied very high pressures with the 4LB (25% achieving pressures > 50 mmHg) whereas the majority of the nurses (75%) achieved a pressure of pressure of 30-50 mmHg was achieved with the new 2LB. The SSB took the least time to be applied (mean: 1 minute 50 seconds) with the 4LB the slowest (mean: 3 minutes 46 seconds). A mean time of 2 minutes 35 seconds was taken to apply the 2LB. Over 63% of the nurses felt the 2LB was very easy to apply. These results suggest that the 2LB achieves the required therapeutic pressure necessary for the management of venous leg ulcers, is easy to apply and may provide a suitable alternative to other multi-layer bandage systems.

  2. Loss of interface pressure in various compression bandage systems over seven days.

    Science.gov (United States)

    Protz, Kerstin; Heyer, Kristina; Verheyen-Cronau, Ida; Augustin, Matthias

    2014-01-01

    Manufacturers' instructions of multi-component compression bandage systems inform that these products can remain up to 7 days during the therapy of venous leg ulcer. This implies that the pressure needed will be sustained during this time. The present research investigated the persistence of pressure of compression systems over 7 days. All 6 compression systems available in Germany at the time of the trial were tested on 35 volunteering persons without signs of venous leg disease. Bandaging with short-stretch bandages was included for comparison. Pressure was measured by using PicoPress®. Initially, all products showed sufficient resting pressure of 40 mm Hg checked with a pressure monitor, except for one system in which the pressure fell by at least 23.8%, the maximum being 47.5% over a period of 7 days. The currently available compression systems are not fit to keep the required pressure. Optimized products need to be developed.

  3. Impact of multilayered compression bandages on sub-bandage interface pressure: a model.

    Science.gov (United States)

    Al Khaburi, J; Nelson, E A; Hutchinson, J; Dehghani-Sanij, A A

    2011-03-01

    Multi-component medical compression bandages are widely used to treat venous leg ulcers. The sub-bandage interface pressures induced by individual components of the multi-component compression bandage systems are not always simply additive. Current models to explain compression bandage performance do not take account of the increase in leg circumference when each bandage is applied, and this may account for the difference between predicted and actual pressures. To calculate the interface pressure when a multi-component compression bandage system is applied to a leg. Use thick wall cylinder theory to estimate the sub-bandage pressure over the leg when a multi-component compression bandage is applied to a leg. A mathematical model was developed based on thick cylinder theory to include bandage thickness in the calculation of the interface pressure in multi-component compression systems. In multi-component compression systems, the interface pressure corresponds to the sum of the pressures applied by individual bandage layers. However, the change in the limb diameter caused by additional bandage layers should be considered in the calculation. Adding the interface pressure produced by single components without considering the bandage thickness will result in an overestimate of the overall interface pressure produced by the multi-component compression systems. At the ankle (circumference 25 cm) this error can be 19.2% or even more in the case of four components bandaging systems. Bandage thickness should be considered when calculating the pressure applied using multi-component compression systems.

  4. Effect of Multi-layer Compression Bandage Systems on Leg Ulcers Associated with Chronic Venous Insufficiency

    Directory of Open Access Journals (Sweden)

    Hüseyin Kuplay

    2013-03-01

    Full Text Available Introduction: Venous leg ulcer is a major health problem in terms of high prevalence and high cost for treatment. Multi-layer compression bandage systems for venous leg ulcers are supposed to be the gold standard for the treatment of venous ulcers. The aim of the current study is to investigate the effectiveness of multi-layer compression bandage systems for the treatment of venous leg ulcers.Patients and Methods: Nineteen consecutive patients diagnosed to have leg ulcers were evaluated and four patients were excluded from the study due to the peripheral arterial disease. Fifteen patients, enrolled in the study, were classified according to CEAP classification and belonged to the same class. Betaven® multi-layer compression bandage was applied to patients. Patients were followed-up in terms of wound healing and reduction in wound diameter.Results: Twelve male and three female patients underwent multi-layer bandage system. Mean age of patients was 38.2 ± 4.2 years. Ulcer size was measured planimetrically and baseline ulcer size was 4-10 cm². The location of ulcer was on medial malloelus in seven patients, lateral malleolus in three patients, anterior surface of the leg in four patients and lateral side of the leg in one patient. Patients had chronic venous insuuficiency for a mean of 5.1 ± 2.1 years. CEAP classifications were C6, Ep, As2,3-p18, Pr2,3, 18. Each bandage was changed five days after application along with wound care. Mean duration of treatment was 6 ± 2 weeks. Complete healing of the venous ulcers occurred in all patients except for one. This patient was referred to plastic surgery clinic for reconstruction.Conclusion: Multi-layer compression bandage system is an effective method of treatment for venous leg ulcers associated with chronic venous insufficiency by reducing venous return and increasing intertitial tissue pressure. This effect occurred in the shortrun as well as with a low cost and prevented loss of labor.

  5. Design and development of novel bandages for compression therapy.

    Science.gov (United States)

    Rajendran, Subbiyan; Anand, Subhash

    2003-03-01

    During the past few years there have been increasing concerns relating to the performance of bandages, especially their pressure distribution properties for the treatment of venous leg ulcers. This is because compression therapy is a complex system and requires two or multi-layer bandages, and the performance properties of each layer differs from other layers. The widely accepted sustained graduated compression mainly depends on the uniform pressure distribution of different layers of bandages, in which textile fibres and bandage structures play a major role. This article examines how the fibres, fibre blends and structures influence the absorption and pressure distribution properties of bandages. It is hoped that the research findings will help medical professionals, especially nurses, to gain an insight into the development of bandages. A total of 12 padding bandages have been produced using various fibres and fibre blends. A new technique that would facilitate good resilience and cushioning properties, higher and more uniform pressure distribution and enhanced water absorption and retention was adopted during the production. It has been found that the properties of developed padding bandages, which include uniform pressure distribution around the leg, are superior to existing commercial bandages and possess a number of additional properties required to meet the criteria stipulated for an ideal padding bandage. Results have indicated that none of the mostly used commercial padding bandages provide the required uniform pressure distribution around the limb.

  6. What is the existing evidence supporting the efficacy of compression bandage systems containing both elastic and inelastic components (mixed-component systems)? A systematic review.

    Science.gov (United States)

    Welsh, Lynn

    2017-05-01

    To analyse current evidence on the efficacy of bandage systems containing both elastic and inelastic components (mixed-component systems). International consensus on the efficacy of types of compression systems is difficult to achieve; however, mixed-component systems are being promoted as combining the best properties of both elastic and inelastic bandage systems and increasingly being used to treat venous leg ulcers in practice. A systematic literature review. Search terms such as venous leg ulcer, varicose ulcer, leg ulcer, compression, bandage, elastic, inelastic, short stretch, healing rate, interface pressure, mixed component, two-layer, four-layer and multi-layer were used in database and hand searches in several combinations. Limits were set for years 2005-March 2015 and English-language publications. A total of 475 studies were identified at initial search, and following elimination from abstract and title, this was reduced to 7. A further study was identified on Google Scholar, bringing the final number of studies fitting inclusion criteria to 8. The following subgroups relating to outcomes of efficacy were identified: ulcer healing, maintenance of interface pressure, slippage, ease of application and patient quality of life. Mixed-component systems were found to have comparable ulcer healing rates to alternative compression systems and be easy to apply; have similar abilities to maintain pressure as four-layer bandages and better abilities than short-stretch bandages; have less slippage than alternative systems; and to be significantly associated with several favourable quality of life outcomes. Clinician skill in bandage application was an uncontrolled variable in all eight papers included in the review, which may limit reliability of findings. This review synthesises existing evidence on the efficacy of mixed-component systems and encourages clinicians to regard them as an effective alternative to purely elastic or inelastic compression systems

  7. Comparison Between a New, Two-component Compression System With Zinc Paste Bandages for Leg Ulcer Healing: A Prospective, Multicenter, Randomized, Controlled Trial Monitoring Sub-bandage Pressures.

    Science.gov (United States)

    Mosti, Giovanni; Crespi, Aldo; Mattaliano, Vincenzo

    2011-05-01

    Compression therapy is standard treatment for venous leg ulcers. The authors prefer multi-layer, multi-component, stiff, high-pressure bandages to treat venous leg ulcers. The Unna boot (UB) is an example of this type of bandage. The aim of this study was to compare the effectiveness and tolerability of UB to a new, two-component bandage. One hundred (100) patients with venous ulcers were randomized into two groups: group A (n = 50) received UB and group B (n = 50) 3M™ Coban™ 2 Layer Compression System (C2L). All patients were followed weekly for 3 months and then monthly until complete healing was achieved. The primary outcomes were: ulcer healing or surface reduction; pain; and exudate control. The secondary outcomes were: ease of application and removal of the bandage, pressure exerted in the supine and standing position after application and before removal, and bandage comfort. C2L was associated with 100% ulcer healing; 47 out of 50 cases healed within the first 3 months after application of the bandage. Compared with the UB, there was no statistically significant difference. In both groups the effect of compression on pain and overall well being was excellent; pain decreased by 50% within 1-2 weeks and remained low throughout the duration of treatment and overall well being improved significantly. There was no significant difference between the two systems concerning level of comfort. C2L proved to be effective in treating venous ulcers due to its stiffness and pressure. Its effectiveness was similar to UB, which is often considered the gold-standard compression device for venous ulcers. This fact, in combination with high tolerability and ease of application and removal, make this new bandage particularly suitable for the treatment of venous leg ulcers. .

  8. Use of customised pressure-guided elastic bandages to improve efficacy of compression bandaging for venous ulcers.

    Science.gov (United States)

    Sermsathanasawadi, Nuttawut; Chatjaturapat, Choedpong; Pianchareonsin, Rattana; Puangpunngam, Nattawut; Wongwanit, Chumpol; Chinsakchai, Khamin; Ruangsetakit, Chanean; Mutirangura, Pramook

    2017-08-01

    Compression bandaging is a major treatment of chronic venous ulcers. Its efficacy depends on the applied pressure, which is dependent on the skill of the individual applying the bandage. To improve the quality of bandaging by reducing the variability in compression bandage interface pressures, we changed elastic bandages into a customised version by marking them with circular ink stamps, applied when the stretch achieves an interface pressure between 35 and 45 mmHg. Repeated applications by 20 residents of the customised bandage and non-marked bandage to one smaller and one larger leg were evaluated by measuring the sub-bandage pressure. The results demonstrated that the target pressure range is more often attained with the customised bandage compared with the non-marked bandage. The customised bandage improved the efficacy of compression bandaging for venous ulcers, with optimal sub-bandage pressure. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  9. Studies of a new multi-layer compression bandage for the treatment of venous ulceration.

    Science.gov (United States)

    Scriven, J M; Bello, M; Taylor, L E; Wood, A J; London, N J

    2000-03-01

    This study aimed to develop an alternative graduated compression bandage for the treatment of venous leg ulcers. Alternative bandage components were identified and assessed for optimal performance as a graduated multi-layer compression bandage. Subsequently the physical characteristics and clinical efficacy of the optimal bandage combination was prospectively examined. Ten healthy limbs were used to develop the optimal combination and 20 limbs with venous ulceration to compare the physical properties of the two bandage types. Subsequently 42 consecutive ulcerated limbs were prospectively treated to examine the efficacy of the new bandage combination. The new combination produced graduated median (range) sub-bandage pressures (mmHg) as follows: ankle 59 (42-100), calf 36 (27-67) and knee 35 (16-67). Over a seven-day period this combination maintained a comparable level of compression with the Charing Cross system, and achieved an overall healing rate at one year of 88%. The described combination should be brought to the attention of healthcare professionals treating venous ulcers as a possible alternative to other forms of multi-layer graduated compression bandages pending prospective, randomised clinical trials.

  10. Pressure mapping and performance of the compression bandage/garment for venous leg ulcer treatment.

    Science.gov (United States)

    Ghosh, S; Mukhopadhyay, A; Sikka, M; Nagla, K S

    2008-08-01

    A study has been conducted on the commercially available compression bandages as regards their performance with time. Pressure mapping of these bandages has been done using a fabricated pressure-measuring device on a mannequin leg to see the effect on pressure due to creep, fabric friction and angle of bandaging. The results show that the creep behavior, frictional behavior and the angle of bandaging have a significant effect on the pressure profile generated by the bandages during application. The regression analysis shows that the surface friction restricts the slippage in a multilayer system. Also the diameters of the limb and the amount of stretch given to the bandage during application have definite impact on the bandage pressure. In case of compression garments, washing improves the pressure generated but not to the extent of the pressure of a virgin garment. Comparing the two compression materials i.e. bandage and garment, it is found that the presence of higher percentage of elastomeric material and a highly close construction in case of garment provides better holding power and a more homogeneous pressure distribution.

  11. [Quality of self-applied compression bandages in patients with chronic venous ulcers : Results of a prospective clinical study].

    Science.gov (United States)

    Stoffels-Weindorf, M; Stoffels, I; Jockenhöfer, F; Dissemond, J

    2018-04-01

    For effective compression therapy in patients with venous leg ulcers, sufficient pressure is essential. In everyday life, it is often the patients themselves who apply the compression bandages. Many of these patients have restriction in their movement and had been rarely trained adequately. Hence, there was the question of how efficient are the autonomously applied compression bandages of those patients. In all, 100 consecutive patients with venous leg ulcer were asked to apply compression bandages on their own leg. We documented both the achieved compression and formal criteria of correct performance. A total of 59 women and 41 men with an average age of 70.3 years were included in the study. Overall 43 patients were not able to apply a compression bandage because of physical limitations. The measured pressure values in the remaining 57 patients ranged between 6 and 93 mm Hg (mean 28.3 mm Hg). Eleven patients reached the prescribed effective compression pressure. Of these, formal errors were found in 6 patients, so that only 5 patients had correctly applied the compression bandages. Our data show that most patients with venous leg ulcers are not able to apply effective compression therapy with short-stretch bandages to themselves. Multilayer systems, adaptive compression bandages, and ulcer stocking systems today are possibly easier and more effective therapy options. Alternatively short-stretch bandages could be applied by trained persons but only under the control with pressure measuring probes.

  12. A compression bandage improves local infiltration analgesia in total knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse; Husted, Henrik; Otte, Niels Kristian Stahl Kri

    2008-01-01

    .2% ropivacaine infiltration analgesia were randomized to receive a compression or a non-compression bandage, and pain was assessed at rest and with mobilization at regular intervals for 24 h postoperatively. RESULTS: Pain at rest, during flexion, or on straight leg lift was lower for the first 8 h in patients...

  13. The influence of different sub-bandage pressure values on venous leg ulcers healing when treated with compression therapy.

    Science.gov (United States)

    Milic, Dragan J; Zivic, Sasa S; Bogdanovic, Dragan C; Jovanovic, Milan M; Jankovic, Radmilo J; Milosevic, Zoran D; Stamenkovic, Dragan M; Trenkic, Marija S

    2010-03-01

    Venous leg ulcers (VLU) have a huge social and economic impact. An estimated 1.5% of European adults will suffer a venous ulcer at some point in their lives. Despite the widespread use of bandaging with high pressure in the treatment of this condition, recurrence rates range between 25% to 70%. Numerous studies have suggested that the compression system should provide sub-bandage pressure values in the range from 35 mm Hg to 45 mm Hg in order to achieve the best possible healing results. An open, randomized, prospective, single-center study was performed in order to determine the healing rates of VLU when treated with different compression systems and different sub-bandage pressure values. One hundred thirty-one patients (72 women, 59 men; mean age, 59-years-old) with VLU (ulcer surface >3 cm(2); duration >3 months) were randomized into three groups: group A - 42 patients who were treated using an open-toed, elastic, class III compression device knitted in tubular form (Tubulcus, Laboratoires Innothera, Arcueil, France); group B - 46 patients treated with the multi-component bandaging system comprised of Tubulcus and one elastic bandage (15 cm wide and 5 cm long with 200% stretch, Niva, Novi Sad, Serbia); and group C - forty-three patients treated with the multi-component bandaging system comprised of Tubulcus and two elastic bandages. Pressure measurements were taken with the Kikuhime device (TT MediTrade, Soro, Denmark) at the B1 measuring point in the supine, sitting, and standing positions under the three different compression systems. The median resting values in the supine and standing positions in examined study groups were as follows: group A - 36.2 mm Hg and 43.9 mm Hg; group B - 53.9 mm Hg and 68.2 mm Hg; group C - 74.0 mm Hg and 87.4 mm Hg. The healing rate during the 26-week treatment period was 25% (13/42) in group A, 67.4% (31/46) in group B, and 74.4% (32/43) in group C. The success of compression treatment in group A was strongly associated with the

  14. Comparison of low-strength compression stockings with bandages for the treatment of recalcitrant venous ulcers.

    Science.gov (United States)

    Brizzio, Eugenio; Amsler, Felix; Lun, Bertrand; Blättler, Werner

    2010-02-01

    To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P ulcers only. Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was

  15. In search of optimal compression therapy for venous leg ulcers: a meta-analysis of studies comparing diverse [corrected] bandages with specifically designed stockings.

    Science.gov (United States)

    Amsler, Felix; Willenberg, Torsten; Blättler, Werner

    2009-09-01

    In search of an optimal compression therapy for venous leg ulcers, a systematic review and meta-analysis was performed of randomized controlled trials (RCT) comparing compression systems based on stockings (MCS) with divers bandages. RCT were retrieved from six sources and reviewed independently. The primary endpoint, completion of healing within a defined time frame, and the secondary endpoints, time to healing, and pain were entered into a meta-analysis using the tools of the Cochrane Collaboration. Additional subjective endpoints were summarized. Eight RCT (published 1985-2008) fulfilled the predefined criteria. Data presentation was adequate and showed moderate heterogeneity. The studies included 692 patients (21-178/study, mean age 61 years, 56% women). Analyzed were 688 ulcerated legs, present for 1 week to 9 years, sizing 1 to 210 cm(2). The observation period ranged from 12 to 78 weeks. Patient and ulcer characteristics were evenly distributed in three studies, favored the stocking groups in four, and the bandage group in one. Data on the pressure exerted by stockings and bandages were reported in seven and two studies, amounting to 31-56 and 27-49 mm Hg, respectively. The proportion of ulcers healed was greater with stockings than with bandages (62.7% vs 46.6%; P bandages better than MCS. Pain was assessed in three studies (219 patients) revealing an important advantage of stockings (P bandages, has a positive impact on pain, and is easier to use.

  16. Randomized trial of four-layer and two-layer bandage systems in the management of chronic venous ulceration.

    Science.gov (United States)

    Moffatt, Christine J; McCullagh, Lynn; O'Connor, Theresa; Doherty, Debra C; Hourican, Catherine; Stevens, Julie; Mole, Trevor; Franks, Peter J

    2003-01-01

    To compare a four-layer bandage system with a two-layer system in the management of chronic venous leg ulceration, a prospective randomized open parallel groups trial was undertaken. In total, 112 patients newly presenting to leg ulcer services with chronic leg ulceration, screened to exclude the presence of arterial disease (ankle brachial pressure index ulceration other than venous disease, were entered into the trial. Patients were randomized to receive either four-layer (Profore) or two-layer (Surepress) high-compression elastic bandage systems. In all, 109 out of 112 patients had at least one follow-up. After 24 weeks, 50 out of 57 (88%) patients randomized to the four-layer bandage system with follow-up had ulcer closure (full epithelialization) compared with 40 out of 52 (77%) on the two-layer bandage, hazard ratio = 1.18 (95% confidence interval 0.69-2.02), p = 0.55. After 12 weeks, 40 out of 57 (70%) patients randomized to the four-layer bandage system with follow-up had ulcer closure compared with 30 out of 52 (58%) on the two-layer bandage, odds ratio = 4.23 (95% confidence interval 1.29-13.86), p = 0.02. Withdrawal rates were significantly greater on the two-layer bandage (30 out of 54; 56%) compared with the four-layer bandage system (8 out of 58; 14%), p bandaging system (15 out of 54; 28%) compared with four-layer bandaging (5 out of 54; 9%), p = 0.01. The higher mean cost of treatment in the two-layer bandaging system arm over 24 weeks ($1374 [ pound 916] vs. $1314 [ pound 876]) was explained by the increased mean number of bandage changes (1.5 vs. 1.1 per week) with the two-layer system. In conclusion, the four-layer bandage offers advantages over the two-layer bandage in terms of reduced withdrawal from treatment, fewer adverse incidents, and lower treatment cost.

  17. Maggots as a wound debridement agent for chronic venous leg ulcers under graduated compression bandages: A randomised controlled trial.

    Science.gov (United States)

    Davies, C E; Woolfrey, G; Hogg, N; Dyer, J; Cooper, A; Waldron, J; Bulbulia, R; Whyman, M R; Poskitt, K R

    2015-12-01

    Slough in chronic venous leg ulcers may be associated with delayed healing. The purpose of this study was to assess larval debridement in chronic venous leg ulcers and to assess subsequent effect on healing. All patients with chronic leg ulcers presenting to the leg ulcer service were evaluated for the study. Exclusion criteria were: ankle brachial pressure indices 1.25, no venous reflux on duplex and ulcer surface covered with slough. Participants were randomly allocated to either 4-layer compression bandaging alone or 4-layer compression bandaging + larvae. Surface areas of ulcer and slough were assessed on day 4; 4-layer compression bandaging was then continued and ulcer size was measured every 2 weeks for up to 12 weeks. A total of 601 patients with chronic leg ulcers were screened between November 2008 and July 2012. Of these, 20 were randomised to 4-layer compression bandaging and 20 to 4-layer compression bandaging + larvae. Median (range) ulcer size was 10.8 (3-21.3) cm(2) and 8.1 (4.3-13.5) cm(2) in the 4-layer compression bandaging and 4-layer compression bandaging + larvae groups, respectively (Mann-Whitney U test, P = 0.184). On day 4, median reduction in slough area was 3.7 cm(2) in the 4-layer compression bandaging group (P bandaging + larvae group. Median percentage area reduction of slough was 50% in the 4-layer compression bandaging group and 84% in the 4-layer compression bandaging + larvae group (Mann-Whitney U test, P bandaging and 4-layer compression bandaging + larvae groups, respectively (Kaplan-Meier analysis, P = 0.664). Larval debridement therapy improves wound debridement in chronic venous leg ulcers treated with multilayer compression bandages. However, no subsequent improvement in ulcer healing was demonstrated. © The Author(s) 2014.

  18. Sub-bandage sensing system for remote monitoring of chronic wounds in healthcare

    Science.gov (United States)

    Hariz, Alex; Mehmood, Nasir; Voelcker, Nico

    2015-12-01

    Chronic wounds, such as venous leg ulcers, can be monitored non-invasively by using modern sensing devices and wireless technologies. The development of such wireless diagnostic tools may improve chronic wound management by providing evidence on efficacy of treatments being provided. In this paper we present a low-power portable telemetric system for wound condition sensing and monitoring. The system aims at measuring and transmitting real-time information of wound-site temperature, sub-bandage pressure and moisture level from within the wound dressing. The system comprises commercially available non-invasive temperature, moisture, and pressure sensors, which are interfaced with a telemetry device on a flexible 0.15 mm thick printed circuit material, making up a lightweight biocompatible sensing device. The real-time data obtained is transmitted wirelessly to a portable receiver which displays the measured values. The performance of the whole telemetric sensing system is validated on a mannequin leg using commercial compression bandages and dressings. A number of trials on a healthy human volunteer are performed where treatment conditions were emulated using various compression bandage configurations. A reliable and repeatable performance of the system is achieved under compression bandage and with minimal discomfort to the volunteer. The system is capable of reporting instantaneous changes in bandage pressure, moisture level and local temperature at wound site with average measurement resolutions of 0.5 mmHg, 3.0 %RH, and 0.2 °C respectively. Effective range of data transmission is 4-5 m in an open environment.

  19. The Canadian Bandaging Trial: Evidence-informed leg ulcer care and the effectiveness of two compression technologies

    OpenAIRE

    Harrison, Margaret B; VanDenKerkhof, Elizabeth G; Hopman, Wilma M; Graham, Ian D; Carley, Meg E; Nelson, E Andrea

    2011-01-01

    Abstract Background Objective: To determine the relative effectiveness of evidence-informed practice using two high compression systems: four-layer (4LB) and short-stretch bandaging (SSB) in community care of venous leg ulcers. Design and Setting: Pragmatic, multi-centre, parallel-group, open-label, randomized controlled trial conducted in 10 centres. Cognitively intact adults (≥18 years) referred for community care (home or clinic) with a venous ulceration measuring ≥0.7cm and present for ≥1...

  20. Comparison of 4-Layer Bandages and an Adaptive Compression Therapy Device on Intended Pressure Delivery.

    Science.gov (United States)

    Mayrovitz, Harvey N; Partsch, Hugo; Vanscheidt, Wolfgang

    2015-01-01

    To characterize and compare interface pressure profiles of an adaptive compression therapy (ACT) device and a traditional 4-layer bandage (4LB) system. A prospective, randomized, open-label, 1-arm, active controlled study. The sample comprised 12 healthy volunteers. Subjects wore both devices for 8 hours on 3 consecutive days. Treatments were randomized to left and right legs. One clinician performed all applications and was experienced in the clinical use of both devices. Pressures were measured in seated and standing positions at the lower, mid, and upper calf immediately post application and after 1, 4, and 8 hours. Pressures achieved with the ACT were closer to targeted 40/30/20 mmHg graduated pressure values and were significantly less than the 4LB for corresponding sites/postures (P pressures (mean ± SD) for the ACT were 36.9 ± 4.9, 30.5 ± 4.5, and 21.0 ± 3.6 mmHg. Corresponding interface pressures for the 4LB were 52.5 ± 8.4, 57.5 ± 10.3, and 53.5 ± 12.9 mmHg. In the standing position, initial interface pressures for the ACT were 40.7 ± 4.8, 35.6 ± 4.5, and 21.1 ± 4.6 compared to 54.6 ± 12.5, 64.4 ± 10.9, and 53.7 ± 14.3 for the 4LB. At 1, 4, and 8 hours after application, the 4LB showed a significant progressive decline in interface pressure in both seated and standing positions (P pressures than the 4LB and the pressures achieved were consistent with contemporary venous ulcer therapy standards.

  1. An investigation of the ability to produce a defined 'target pressure' using the PressCise compression bandage.

    Science.gov (United States)

    Wiklander, Kerstin; Andersson, Annette Erichsen; Källman, Ulrika

    2016-12-01

    Compression therapy is the cornerstone in the prevention and treatment of leg ulcers related to chronic venous insufficiency. The application of optimal high pressure is essential for a successful outcome, but the literature has reported difficulty applying the intended pressure, even among highly skilled nurses. The PressCise bandage has a novel design, with both longitudinal and horizontal reference points for correct application. In the current experimental study, the results for the general linear model, where the data set is treated optimally, showed that all 95% confidence intervals of the expected values for pressure were, at most, 5 mmHg from the target value of 50 mmHg, independent of the position on the leg and the state of activity. Moreover, even nurses with limited experience were consistently able to reach the targeted pressure goal. Future studies are needed to determine how well the bandage works on legs of different shapes, the optimal way of using the bandage (day only or both day and night) and whether the bandage should be combined with an outer bandage layer. In addition, special attention should be paid to subjective patient experiences in relation to the treatment as pain, discomfort and bulk are factors that can compromise patients' willingness to adhere to the treatment protocol and thereby prolong the healing process. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  2. The Canadian Bandaging Trial: Evidence-informed leg ulcer care and the effectiveness of two compression technologies

    Directory of Open Access Journals (Sweden)

    Hopman Wilma M

    2011-10-01

    Full Text Available Abstract Background Objective: To determine the relative effectiveness of evidence-informed practice using two high compression systems: four-layer (4LB and short-stretch bandaging (SSB in community care of venous leg ulcers. Design and Setting: Pragmatic, multi-centre, parallel-group, open-label, randomized controlled trial conducted in 10 centres. Cognitively intact adults (≥18 years referred for community care (home or clinic with a venous ulceration measuring ≥0.7cm and present for ≥1 week, with an ankle brachial pressure index (ABPI ≥0.8, without medication-controlled Diabetes Mellitus or a previous failure to improve with either system, were eligible to participate. Methods Consenting individuals were randomly allocated (computer-generated blocked randomization schedule to receive either 4LB or SSB following an evidence-informed protocol. Primary endpoint: time-to- healing of the reference ulcer. Secondary outcomes: recurrence rates, health-related quality of life (HRQL, pain, and expenditures. Results 424 individuals were randomized (4LB n = 215; SSB n = 209 and followed until their reference ulcer was healed (or maximum 30 months. An intent-to-treat analysis was conducted on all participants. Median time to ulcer healing in the 4LB group was 62 days [95% confidence interval (CI 51 to 73], compared with 77 days (95% CI 63 to 91 in the SSB group. The unadjusted Kaplan-Meier curves revealed the difference in the distribution of cumulative healing times was not significantly different between group (log rank χ2 = 0.001, P = 0.98 nor ulcers recurrence (4LB, 10.1%; SSB, 13.3%; p = 0.345. Multivariable Cox Proportional Hazard Modeling also showed no significant between-bandage differences in healing time after controlling for significant covariates (p = 0.77. At 3-months post-baseline there were no differences in pain (no pain: 4LB, 22.7%; SSB, 26.7%; p = 0.335, or HRQL (SF-12 Mental Component Score: 4LB, 55.1; SSB, 55.8; p = 0.615; SF

  3. The Canadian Bandaging Trial: Evidence-informed leg ulcer care and the effectiveness of two compression technologies

    Science.gov (United States)

    2011-01-01

    Background Objective: To determine the relative effectiveness of evidence-informed practice using two high compression systems: four-layer (4LB) and short-stretch bandaging (SSB) in community care of venous leg ulcers. Design and Setting: Pragmatic, multi-centre, parallel-group, open-label, randomized controlled trial conducted in 10 centres. Cognitively intact adults (≥18 years) referred for community care (home or clinic) with a venous ulceration measuring ≥0.7cm and present for ≥1 week, with an ankle brachial pressure index (ABPI) ≥0.8, without medication-controlled Diabetes Mellitus or a previous failure to improve with either system, were eligible to participate. Methods Consenting individuals were randomly allocated (computer-generated blocked randomization schedule) to receive either 4LB or SSB following an evidence-informed protocol. Primary endpoint: time-to- healing of the reference ulcer. Secondary outcomes: recurrence rates, health-related quality of life (HRQL), pain, and expenditures. Results 424 individuals were randomized (4LB n = 215; SSB n = 209) and followed until their reference ulcer was healed (or maximum 30 months). An intent-to-treat analysis was conducted on all participants. Median time to ulcer healing in the 4LB group was 62 days [95% confidence interval (CI) 51 to 73], compared with 77 days (95% CI 63 to 91) in the SSB group. The unadjusted Kaplan-Meier curves revealed the difference in the distribution of cumulative healing times was not significantly different between group (log rank χ2 = 0.001, P = 0.98) nor ulcers recurrence (4LB, 10.1%; SSB, 13.3%; p = 0.345). Multivariable Cox Proportional Hazard Modeling also showed no significant between-bandage differences in healing time after controlling for significant covariates (p = 0.77). At 3-months post-baseline there were no differences in pain (no pain: 4LB, 22.7%; SSB, 26.7%; p = 0.335), or HRQL (SF-12 Mental Component Score: 4LB, 55.1; SSB, 55.8; p = 0.615; SF-12 Physical

  4. Clinical and cost-effectiveness of compression hosiery versus compression bandages in treatment of venous leg ulcers (Venous leg Ulcer Study IV, VenUS IV): a randomised controlled trial.

    Science.gov (United States)

    Ashby, Rebecca L; Gabe, Rhian; Ali, Shehzad; Adderley, Una; Bland, J Martin; Cullum, Nicky A; Dumville, Jo C; Iglesias, Cynthia P; Kang'ombe, Arthur R; Soares, Marta O; Stubbs, Nikki C; Torgerson, David J

    2014-03-08

    Drawbacks exist with the standard treatment (four-layer compression bandages) for venous leg ulcers. We have therefore compared the clinical effectiveness and cost-effectiveness of two-layer compression hosiery with the four-layer bandage for the treatment of such ulcers. We undertook this pragmatic, open, randomised controlled trial with two parallel groups in 34 centres in England and Northern Ireland. The centres were community nurse teams or services, family doctor practices, leg ulcer clinics, tissue viability clinics or services, and wound clinics. Participants were aged 18 years or older with a venous leg ulcer and an ankle brachial pressure index of at least 0·8, and were tolerant of high compression. We randomly allocated participants (1:1) to receive two-layer compression hosiery or a four-layer bandage, using a remote randomisation service and prevalidated computer randomisation program. Participants were stratified by ulcer duration and ulcer area with permuted blocks (block sizes four and six). The primary endpoint was time to ulcer healing, with a maximum follow-up of 12 months. Although participants and health-care providers were not masked to treatment allocation, the primary endpoint was measured by masked assessment of photographs. Primary analysis was intention to treat with Cox regression, with adjustment for ulcer area, ulcer duration, physical mobility, and centre. This trial is registered with the ISRCTN register, number ISRCTN49373072. We randomly allocated 457 participants to the two treatment groups: 230 to two-layer hosiery and 227 to the four-layer bandage, of whom 453 (230 hosiery and 223 bandage) contributed data for analysis. Median time to ulcer healing was 99 days (95% CI 84-126) in the hosiery group and 98 days (85-112) in the bandage group, and the proportion of ulcers healing was much the same in the two groups (70·9% hosiery and 70·4% bandage). More hosiery participants changed their allocated treatment (38·3% hosiery vs 27

  5. Comparison of the effectiveness of complex decongestive therapy and compression bandaging as a method of treatment of lymphedema in the elderly

    Directory of Open Access Journals (Sweden)

    Zasadzka E

    2018-05-01

    Full Text Available Ewa Zasadzka,1 Tomasz Trzmiel,1 Maria Kleczewska,2 Mariola Pawlaczyk1 1Department of Geriatric Medicine and Gerontology, Karol Marcinkowski University of Medical Sciences, Poznan, Poland; 2Day Rehabilitation Center, Hospicjum Palium, Poznań, Poland Background: Lymphedema is a chronic condition which significantly lowers the quality of patient life, particularly among elderly populations, whose mobility and physical function are often reduced. Objectives: The aim of the study was to compare the effectiveness of multi-layer compression bandaging (MCB and complex decongestive therapy (CDT, and to show that MCB is a cheaper, more accessible and less labor intensive method of treating lymphedema in elderly patients. Patients and methods: The study included 103 patients (85 women and 18 men aged ≥60 years, with unilateral lower limb lymphedema. The subjects were divided into two groups: 50 treated with CDT and 53 with MCB. Pre- and post-treatment BMI, and average and maximum circumference of the edematous extremities were analyzed. Results: Reduction in swelling in both groups was achieved after 15 interventions. Both therapies demonstrated similar efficacy in reducing limb volume and circumference, but MCB showed greater efficacy in reducing the maximum circumference. Conclusion: Compression bandaging is a vital component of CDT. Maximum lymphedema reduction during therapy and maintaining its effect cannot be achieved without it. It also demonstrates its effectiveness as an independent method, which can reduce therapy cost and accessibility. Keywords: lymphedema, elderly, therapy, compression bandaging

  6. Sustained compression and healing of chronic venous ulcers.

    OpenAIRE

    Blair, S. D.; Wright, D. D.; Backhouse, C. M.; Riddle, E.; McCollum, C. N.

    1988-01-01

    STUDY OBJECTIVE--Comparison of four layer bandage system with traditional adhesive plaster bandaging in terms of (a) compression achieved and (b) healing of venous ulcers. DESIGN--Part of larger randomised trial of five different dressings. SETTING--Outpatient venous ulcer clinic in university hospital. PATIENTS--(a) Pressure exerted by both bandage systems was measured in the same 20 patients. (b) Healing with the four layer bandage was assessed in 148 legs in 126 consecutive patients (mean ...

  7. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  8. Customizing elastic pressure bandages for reuse to a predetermined, sub-bandage pressure: A randomized controlled trial.

    Science.gov (United States)

    Sermsathanasawadi, Nuttawut; Tarapongpun, Tanakorn; Pianchareonsin, Rattana; Puangpunngam, Nattawut; Wongwanit, Chumpol; Chinsakchai, Khamin; Mutirangura, Pramook; Ruangsetakit, Chanean

    2017-01-01

    Objective A randomized clinical trial was performed to compare the effectiveness of unmarked bandages and customized bandages with visual markers in reproducing the desired sub-bandage pressure during self-bandaging by patients. Method Ninety patients were randomly allocated to two groups ("customized bandages" and "unmarked bandages") and asked to perform self-bandaging three times. The achievement of a pressure between 35 and 45 mmHg in at least two of the three attempts was defined as adequate quality. Results Adequate quality was achieved by 33.0% when applying the unmarked bandages, and 60.0% when applying the customized bandages ( p = 0.02). Use of the customized bandage and previous experience of bandaging were independent predictors for the achievement of the predetermined sub-bandage pressure ( p = 0.005 and p = 0.021, respectively). Conclusion Customized bandages may achieve predetermined sub-bandage pressures more closely than standard, unmarked, compression bandages. Clinical trials registration ClinicalTrials.gov (NCT02729688). Effectiveness of a Pressure Indicator Guided and a Conventional Bandaging in Treatment of Venous Leg Ulcer. https://clinicaltrials.gov/ct2/show/NCT02729688.

  9. Evaluation of Two Miniplate Systems and Figure-of-eight Bandages for Stabilization of Experimentally Induced Ulnar and Radial Fractures in Pigeons ( Columba livia ).

    Science.gov (United States)

    Bennert, Beatrice M; Kircher, Patrick R; Gutbrod, Andreas; Riechert, Juliane; Hatt, Jean-Michel

    2016-06-01

    Although plate fixation has advantages over other fixation methods for certain indications, it is rarely used in avian surgery, especially in birds that weigh less than 1000 g. Exceptionally small plating systems for these birds are required, which are relatively expensive and difficult to insert. To study avian fracture healing after repair using miniplates, we evaluated 2 steel miniplate systems in 27 pigeons ( Columba livia ) divided into 4 groups. In each pigeon, the left ulna and radius were transected and the ulna was repaired with a bone plate. In groups A and B, a 1.3-mm adaption plate was applied without and with a figure-of-eight bandage; in groups C and D, a 1.0-mm compression plate was applied without and with a bandage, respectively. Healing was evaluated with radiographs after 3, 14, and 28 days; flight tests were conducted after 14, 21, and 28 days; and the wing was macroscopically examined after euthanasia of birds on day 28. Fractures healed without bending or distortion of the plate in all 27 birds, and no significant differences in healing were found between treatment groups. At the end of the study, 23 pigeons (85.2%) showed good or very good flight ability. Results show the 1.3-mm adaption plate and the 1.0-mm compression plate meet the requirements for avian osteosynthesis and can be recommended for fracture repair of the ulna or other long bones in birds weighing less than 500 g. The application of a figure-of-eight bandage might be beneficial in fracture healing.

  10. Sustained compression and healing of chronic venous ulcers.

    Science.gov (United States)

    Blair, S. D.; Wright, D. D.; Backhouse, C. M.; Riddle, E.; McCollum, C. N.

    1988-01-01

    STUDY OBJECTIVE--Comparison of four layer bandage system with traditional adhesive plaster bandaging in terms of (a) compression achieved and (b) healing of venous ulcers. DESIGN--Part of larger randomised trial of five different dressings. SETTING--Outpatient venous ulcer clinic in university hospital. PATIENTS--(a) Pressure exerted by both bandage systems was measured in the same 20 patients. (b) Healing with the four layer bandage was assessed in 148 legs in 126 consecutive patients (mean age 71 (SE 2); range 30-96) with chronic venous ulcers that had resisted treatment with traditional bandaging for a mean of 27.2 (SE 8) months. INTERVENTIONS--(a) Four layer bandage system or traditional adhesive plaster bandaging for pressure studies; (b) four layer bandaging applied weekly for studies of healing. END POINTS--(a) Comparison of pressures achieved at the ankle for up to one week; (b) complete healing within 12 weeks. MEASUREMENTS AND MAIN RESULTS--(a) Four layer bandage produced higher initial pressures at the ankle of 42.5 (SE 1) mm Hg compared with 29.8 (1.8) for the adhesive plaster (p less than 0.001; 95% confidence interval 18.5 to 6.9). Pressure was maintained for one week with the four layer bandage but fell to 10.4 (3.5) mm Hg at 24 hours with adhesive plaster bandaging. (b) After weekly bandaging with the four layer bandage 110 of 48 venous ulcers had healed completely within 12 (mean 6.3 (0.4)) weeks. CONCLUSION--Sustained compression of over 40 mm Hg achieved with a multilayer bandage results in rapid healing of chronic venous ulcers that have failed to heal in many months of compression at lower pressures with more conventional bandages. PMID:3144330

  11. Inkjet printed wireless smart bandage

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    Chronic wounds affect millions of patients around the world and requires a major portion of health care budget for treatment. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage strip, which can send early warnings as well as record long term wound progression data. The smart bandage can communicate upto a distance of 60 m when worn on the body.

  12. Inkjet printed wireless smart bandage

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    Chronic wounds affect millions of patients around the world and requires a major portion of health care budget for treatment. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage strip, which can send early warnings as well as record long term wound progression data. The smart bandage can communicate upto a distance of 60 m when worn on the body.

  13. Experimental study on efficacy of compression systems with a high static stiffness index for treatment of venous ulcer patients

    Directory of Open Access Journals (Sweden)

    Anneke Andriessen

    2013-03-01

    Full Text Available The experimental study measured interface pressure and static stiffness index of four different compression systems in fifty-two healthy volunteers. For the study interface pressure (3 cm ø probe was placed at the anatomical B1 point was recorded on application of the compression systems every 15 min for 4 h, in supine, standing, while sitting and during walking. For this purpose a portable Kikuhime (Harada Corp., Osaka, Japan device was used. Further static stiffness index (SSI was calculated. The evaluated systems were: short stretch bandage system (SSB Rosidal sys (Lohmann & Rauscher, Rengsdorf, Germany, multi-layer bandaging (LSB Profore (Smith & Nephew, Hull, UK, varistretch bandage (VSB Proguide (Smith & Nephew and tubular compression (CS Rosidal mobil (Lohmann & Rauscher. The mean interface pressure of SSB, LSB and VSB was significantly higher (P<0.05 in each position measured over 4 h, compared to CS. In supine VSB showed high-pressure levels, up to 60 mmHg, which remained high. The other systems had more tolerable levels of about 30 mmHg. Interface pressure exerted on limbs is an indicator of their clinical effect. The experimental study results showed different patterns of interface pressure and SSI, which may enable clinicians to predict the frequency of bandage application, supporting an adequate and safe choice of bandage system.

  14. Expansive cements for the manufacture of the concrete protective bandages

    Science.gov (United States)

    Yakymechko, Yaroslav; Voloshynets, Vladyslav

    2017-12-01

    One of the promising directions of the use of expansive cements is making the protective bandages for the maintenance of pipelines. Bandages expansive application of the compositions of the pipeline reinforce the damaged area and reduce stress due to compressive stress in the cylindrical area. Such requirements are best suited for expansive compositions obtained from portland cement and modified quicklime. The article presents the results of expansive cements based on quick lime in order to implement protective bandages pipelines.

  15. Interface pressure is affected by slippage of bandages at thigh.

    Science.gov (United States)

    Miyazaki, K; Hirai, M; Koyama, A; Iwata, H; Ohashi, M; Ota, A

    2012-12-01

    Very little is known about how compression bandages lose interface pressure. We hypothesized that the loss of interface pressure is correlated with the slippage of the bandages, and studied the interface pressure and slippage of three bandages over 8 hours. Twenty-Seven legs from 27 healthy volunteers were bandaged with short stretch bandages (SS), cohesive short stretch bandages (CS), and long stretch bandages (LS). Pressure sensors were placed above the ankle (B1), below the knee (D), and mid thigh (F). Interface pressures in a sitting position were recorded at the beginning, and 4 and 8 hours later. In 17 legs, the pressure sensor sites were marked, and their heights were measured on standing upright. SS and CS lost interface pressure quickly, but LS maintained pressure better than SS and CS at all sites. There was no pressure difference between SS and CS at the lower leg. However, CS maintained pressure better than SS at the mid thigh (44.6% vs. 54.4% pressure loss at 8 hours, respectively. P=0.037). There was a tendency toward less slippage with CS than SS at the mid thigh. In CS and LS, there was a linear correlation between the slippage of bandages and the interface pressure at the mid thigh (P pressure may be affected by the slippage of bandages at the thigh, but not at the lower leg. Cohesive short stretch bandages may exert their beneficial impact at the thigh.

  16. The production and measurement of sub-bandage pressure: Laplace's Law revisited.

    Science.gov (United States)

    Thomas, S

    2014-05-01

    The present study was undertaken to demonstrate that the pressures produced by multiple layers of compression bandages applied to artificial limbs of known circumference with predetermined levels of tension can be predicted accurately using the modified Laplace equation. Up to four layers of different bandage types were applied in a carefully controlled fashion to cylinders of known circumference, with tensions ranging from around 200-2000 grams/10cm width. The pressures generated were measured using pneumatic pressure sensors previously shown to possess the required degree of accuracy for this type of experimental system. Good correlation was observed between the mean and standard deviation of each pair of experimental and calculated pressure values for all combinations of bandage type, application tension and cylinder circumference. Over the clinically relevant range of pressures, the difference between data sets was generally less than 1.0mmHg. The results of this experimental study unequivocally prove that provided accurate values for all the relevant variables are known, it is possible to predict the pressure that will be developed by a compression bandage on a limb of known size. However, it is important to recognise that other factors such as the elastomeric properties of the fabric will have a major effect upon the ability of a bandage system to sustain initial compression values. Furthermore, the variation in radius of curvature around a limb will mean that point pressures readings recorded at individual locations around the circumference may vary dramatically from the average value predicted by the modified Laplace equation, calling into question the value of sub-bandage pressure measuring devices for this application.

  17. Comparison of the effectiveness of compression stockings and layer compression systems in venous ulceration treatment

    Science.gov (United States)

    Jawień, Arkadiusz; Cierzniakowska, Katarzyna; Cwajda-Białasik, Justyna; Mościcka, Paulina

    2010-01-01

    Introduction The aim of the research was to compare the dynamics of venous ulcer healing when treated with the use of compression stockings as well as original two- and four-layer bandage systems. Material and methods A group of 46 patients suffering from venous ulcers was studied. This group consisted of 36 (78.3%) women and 10 (21.70%) men aged between 41 and 88 years (the average age was 66.6 years and the median was 67). Patients were randomized into three groups, for treatment with the ProGuide two-layer system, Profore four-layer compression, and with the use of compression stockings class II. In the case of multi-layer compression, compression ensuring 40 mmHg blood pressure at ankle level was used. Results In all patients, independently of the type of compression therapy, a few significant statistical changes of ulceration area in time were observed (Student’s t test for matched pairs, p ulceration area in each of the successive measurements was observed in patients treated with the four-layer system – on average 0.63 cm2/per week. The smallest loss of ulceration area was observed in patients using compression stockings – on average 0.44 cm2/per week. However, the observed differences were not statistically significant (Kruskal-Wallis test H = 4.45, p > 0.05). Conclusions A systematic compression therapy, applied with preliminary blood pressure of 40 mmHg, is an effective method of conservative treatment of venous ulcers. Compression stockings and prepared systems of multi-layer compression were characterized by similar clinical effectiveness. PMID:22419941

  18. Temporal compressive sensing systems

    Science.gov (United States)

    Reed, Bryan W.

    2017-12-12

    Methods and systems for temporal compressive sensing are disclosed, where within each of one or more sensor array data acquisition periods, one or more sensor array measurement datasets comprising distinct linear combinations of time slice data are acquired, and where mathematical reconstruction allows for calculation of accurate representations of the individual time slice datasets.

  19. CONVENTIONAL MASTOID BANDAGE FOLLOWING OTOLOGICAL SURGERIES - IS IT NECESSARY?

    Directory of Open Access Journals (Sweden)

    Sumit

    2016-03-01

    Full Text Available BACKGROUND Mastoid pressure bandage post otological surgeries are usually applied to prevent post-operative wound haematoma and proper wound cover. Many other materials (e.g. Micropore, Dynaplast are used instead of conventional bandage. AIMS The purpose of this study was to assess whether compressive head bandages are necessary after ear surgery to prevent complications such as haematoma or wound infection. METHODS A hospital based study of 50 patients (30 males & 20 females who underwent tympano-mastoidectomies, were selectively applied different types of mastoid bandages, following which their advantages & disadvantages post-operatively (early & late were studied. RESULTS Out of 50 cases, in which 15 cases were applied conventional mastoid bandage resulted in 4 complications (26.66%. Whereas out of 20 cases of Dynaplast bandage, only 2 showed minor complications (10% with only pain during removal of this bandage. Out of 15 cases where Micropore was used as bandage, only 2 showed up with minor complications (13.33% with only pain during removal of Micropore.

  20. Venous Leg Ulcers: Effectiveness of new compression therapy/moist ...

    African Journals Online (AJOL)

    (Cutimed Sorbact) and compression bandages (Comprilan,. Tensoplast) in the initial oedema phase, followed by a compression stocking system delivering 40mmHg (JOBST. UlcerCARE). Due to their high stiffness characteristics, these compression products exert a high working pressure during walking and a comfortably ...

  1. The use of strapping to increase local pressure: reporting of a sub-bandage pressure study

    OpenAIRE

    Alison Hopkins; Fran Worboys; Hugo Partsch

    2013-01-01

    High compression is the gold standard for venous ulcer management. This brief report presents the results of a sub-bandage pressure study that investigated the pressures received from compression therapy in the region of the retromalleolal fossa. The study tested the hypothesis that therapeutic compression is not achieved behind the malleolus. The results confirm this, showing that less that 5-mmHg sub-bandage pressure is achieved despite high compression at the B1 level. This report demonstr...

  2. Macro- and microperfusion during application of a new compression system, designed for patients with leg ulcer and concomitant peripheral arterial occlusive disease.

    Science.gov (United States)

    Jünger, Michael; Haase, Hermann; Schwenke, Linda; Bichel, Jens; Schuren, Jan; Ladwig, Andrea

    2013-01-01

    To investigate macro- and microperfusion during 14 days of treatment with a new 2-layer compression system (3M™ Coban™ 2 Lite), designed for patients with leg ulcer and concomitant peripheral arterial occlusive disease. A single-centre, open-label, prospective pilot study was performed with 15 subjects suffering from peripheral arterial occlusive disease with an ankle brachial pressure index (ABPI) of 0.5-0.8, who volunteered to have their 'study leg' bandaged with the new system. Coincident leg ulcer or chronic venous disease was not mandatory. All subjects received the new compression system, which stayed in place from 1 up to 4 days according to scheduled study visits. The system was reapplied by study personnel at each clinical visit (days 1, 2, 3, 4, 7, 10 and 14). The study participation stopped after 14 days. At each clinical visit safety assessments were performed: measurement of acral pulsation to capture macroperfusion; laser Doppler fluxmetry to capture microperfusion; clinical signs of pressure related skin damage, hypoxia-related pain and sub-bandage pressure measurement. In addition, the leg volume was measured and a comfort questionnaire was completed. An average sub-bandage pressure in standing position of approximately 30 mmHg was measured at the B1 location immediately after bandage application. Laser Doppler fluxmetry demonstrated positive effects on microcirculation regarding vasomotion and respiratory reflux. No change of the cardiac signal appeared. For acrale pulsations a high intraindividual variability was found with no clear interference to the bandage application. No pressure-related skin damage or hypoxia-related pain was detected. After application of the new compression system in subjects with moderate PAOD, laser Doppler fluxmetry indicated significant improvements of the microcirculation. High variability and lack of correlation to clinical symptoms was found for the acral pulsation. The new compression system revealed a high

  3. Compressive Sensing in Communication Systems

    DEFF Research Database (Denmark)

    Fyhn, Karsten

    2013-01-01

    . The need for cheaper, smarter and more energy efficient wireless devices is greater now than ever. This thesis addresses this problem and concerns the application of the recently developed sampling theory of compressive sensing in communication systems. Compressive sensing is the merging of signal...... acquisition and compression. It allows for sampling a signal with a rate below the bound dictated by the celebrated Shannon-Nyquist sampling theorem. In some communication systems this necessary minimum sample rate, dictated by the Shannon-Nyquist sampling theorem, is so high it is at the limit of what...... with using compressive sensing in communication systems. The main contribution of this thesis is two-fold: 1) a new compressive sensing hardware structure for spread spectrum signals, which is simpler than the current state-of-the-art, and 2) a range of algorithms for parameter estimation for the class...

  4. Compressed gas fuel storage system

    Science.gov (United States)

    Wozniak, John J.; Tiller, Dale B.; Wienhold, Paul D.; Hildebrand, Richard J.

    2001-01-01

    A compressed gas vehicle fuel storage system comprised of a plurality of compressed gas pressure cells supported by shock-absorbing foam positioned within a shape-conforming container. The container is dimensioned relative to the compressed gas pressure cells whereby a radial air gap surrounds each compressed gas pressure cell. The radial air gap allows pressure-induced expansion of the pressure cells without resulting in the application of pressure to adjacent pressure cells or physical pressure to the container. The pressure cells are interconnected by a gas control assembly including a thermally activated pressure relief device, a manual safety shut-off valve, and means for connecting the fuel storage system to a vehicle power source and a refueling adapter. The gas control assembly is enclosed by a protective cover attached to the container. The system is attached to the vehicle with straps to enable the chassis to deform as intended in a high-speed collision.

  5. Compressed sensing for distributed systems

    CERN Document Server

    Coluccia, Giulio; Magli, Enrico

    2015-01-01

    This book presents a survey of the state-of-the art in the exciting and timely topic of compressed sensing for distributed systems. It has to be noted that, while compressed sensing has been studied for some time now, its distributed applications are relatively new. Remarkably, such applications are ideally suited to exploit all the benefits that compressed sensing can provide. The objective of this book is to provide the reader with a comprehensive survey of this topic, from the basic concepts to different classes of centralized and distributed reconstruction algorithms, as well as a comparison of these techniques. This book collects different contributions on these aspects. It presents the underlying theory in a complete and unified way for the first time, presenting various signal models and their use cases. It contains a theoretical part collecting latest results in rate-distortion analysis of distributed compressed sensing, as well as practical implementations of algorithms obtaining performance close to...

  6. The use of strapping to increase local pressure: reporting of a sub-bandage pressure study

    Directory of Open Access Journals (Sweden)

    Alison Hopkins

    2013-04-01

    Full Text Available High compression is the gold standard for venous ulcer management. This brief report presents the results of a sub-bandage pressure study that investigated the pressures received from compression therapy in the region of the retromalleolal fossa. The study tested the hypothesis that therapeutic compression is not achieved behind the malleolus. The results confirm this, showing that less that 5-mmHg sub-bandage pressure is achieved despite high compression at the B1 level. This report demonstrates that the application of novel strapping below the malleolus substantially increases the compression at rest, standing and dorsiflexion. The clinical implications of this are discussed.

  7. Study of the effect of composition and construction of material on sub-bandage pressure during dynamic loading of a limb in vitro.

    Science.gov (United States)

    Kumar, Bipin; Das, Apurba; Alagirusamy, R

    2013-01-01

    Internal stress in a compression bandage wrapped over a limb in vitro is expected to reduce over time because of fatigue which may occur due to repetitive and prolonged variations in the extension of the bandage during posture change and exercise. This phenomenon may cause significant variation in the sub-bandage pressure over time. To examine the effect of composition and construction of material on the sub-bandage pressure variation over time in the dynamic state of a limb in the laboratory. Yarns comprising fibers of polyester, viscose, cotton and elastomeric yarn were used to prepare different knitted bandage samples having varying thread densities in the structure. A leg-segment prototype was used for the measurement of the interface pressure over a mannequin limb to analyse different bandages under similar dynamic conditions. The pressure drop in the dynamic state of the mannequin limb was greater than that in the static state. The mean pressure drop in 2 h in the dynamic state was greater by >30% for bandages made of pure cotton or viscose yarns than for bandages having elastomeric yarns in their structure. At the same applied tension, increasing the number of yarns per unit length in the bandage structure resulted in a smaller drop in pressure in the dynamic mode. Elastomeric yarn improves the elasticity and fatigue resistance of the bandage. Therefore, these yarns should be used in bandages to obtain sustained compression effects under dynamic conditions.

  8. Neuromuscular Bandage: Neurophysiological Effects and the Role of Fascias

    Directory of Open Access Journals (Sweden)

    Ximena María Villota Chicaíza

    2014-05-01

    Full Text Available During the last years, neuromuscular bandage, a therapeutic application created in 1979 by doctor Kenzo Kase has been introduced in the management of many disorders of the musculo-skeletal system and even more so in the treatment of neurological disorders; This therapeutic tool which consists of a self adhesive elastic bandage allows recovery of the injured party without diminishing its bodily function. According to the existing literature on the physiological effects of this therapeutic application in the body, you could say that there is consensus. However in this article the author wants to highlight the significant although little highlighted role played by the fas¬cias on the therapeutic effects of neuromuscular bandage, analyzing from a reflective perspective the analgesic, neuromechanical and circulatory effects, as fundamental effects of neuromuscular bandage and fascias in the same function, trying to bring a global understanding on the way they relate to all connective tissues, aspects that are of great importance for the proper evaluation of alterations and prescription of neuromuscular bandage

  9. 30 CFR 75.1730 - Compressed air; general; compressed air systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compressed air; general; compressed air systems... Compressed air; general; compressed air systems. (a) All pressure vessels shall be constructed, installed... Safety and Health district office. (b) Compressors and compressed-air receivers shall be equipped with...

  10. Efficient Lossy Compression for Compressive Sensing Acquisition of Images in Compressive Sensing Imaging Systems

    Directory of Open Access Journals (Sweden)

    Xiangwei Li

    2014-12-01

    Full Text Available Compressive Sensing Imaging (CSI is a new framework for image acquisition, which enables the simultaneous acquisition and compression of a scene. Since the characteristics of Compressive Sensing (CS acquisition are very different from traditional image acquisition, the general image compression solution may not work well. In this paper, we propose an efficient lossy compression solution for CS acquisition of images by considering the distinctive features of the CSI. First, we design an adaptive compressive sensing acquisition method for images according to the sampling rate, which could achieve better CS reconstruction quality for the acquired image. Second, we develop a universal quantization for the obtained CS measurements from CS acquisition without knowing any a priori information about the captured image. Finally, we apply these two methods in the CSI system for efficient lossy compression of CS acquisition. Simulation results demonstrate that the proposed solution improves the rate-distortion performance by 0.4~2 dB comparing with current state-of-the-art, while maintaining a low computational complexity.

  11. Energy Conservation In Compressed Air Systems

    International Nuclear Information System (INIS)

    Yusuf, I.Y.; Dewu, B.B.M.

    2004-01-01

    Compressed air is an essential utility that accounts for a substantial part of the electricity consumption (bill) in most industrial plants. Although the general saying Air is free of charge is not true for compressed air, the utility's cost is not accorded the rightful importance due to its by most industries. The paper will show that the cost of 1 unit of energy in the form of compressed air is at least 5 times the cost electricity (energy input) required to produce it. The paper will also provide energy conservation tips in compressed air systems

  12. Bond graph modeling of centrifugal compression systems

    OpenAIRE

    Uddin, Nur; Gravdahl, Jan Tommy

    2015-01-01

    A novel approach to model unsteady fluid dynamics in a compressor network by using a bond graph is presented. The model is intended in particular for compressor control system development. First, we develop a bond graph model of a single compression system. Bond graph modeling offers a different perspective to previous work by modeling the compression system based on energy flow instead of fluid dynamics. Analyzing the bond graph model explains the energy flow during compressor surge. Two pri...

  13. Wearable Wireless Tyrosinase Bandage and Microneedle Sensors: Toward Melanoma Screening.

    Science.gov (United States)

    Ciui, Bianca; Martin, Aida; Mishra, Rupesh K; Brunetti, Barbara; Nakagawa, Tatsuo; Dawkins, Thomas J; Lyu, Mengjia; Cristea, Cecilia; Sandulescu, Robert; Wang, Joseph

    2018-04-01

    Wearable bendable bandage-based sensor and a minimally invasive microneedle biosensor are described toward rapid screening of skin melanoma. These wearable electrochemical sensors are capable of detecting the presence of the tyrosinase (TYR) enzyme cancer biomarker in the presence of its catechol substrate, immobilized on the transducer surface. In the presence of the surface TYR biomarker, the immobilized catechol is rapidly converted to benzoquinone that is detected amperometrically, with a current signal proportional to the TYR level. The flexible epidermal bandage sensor relies on printing stress-enduring inks which display good resiliency against mechanical deformations, whereas the hollow microneedle device is filled with catechol-coated carbon paste for assessing tissue TYR levels. The bandage sensor can thus be used directly on the skin whereas microneedle device can reach melanoma tissues under the skin. Both wearable sensors are interfaced to an ultralight flexible electronic board, which transmits data wirelessly to a mobile device. The analytical performance of the resulting bandage and microneedle sensing systems are evaluated using TYR-containing agarose phantom gel and porcine skin. The new integrated conformal portable sensing platforms hold considerable promise for decentralized melanoma screening, and can be extended to the screening of other key biomarkers in skin moles. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Compressed air energy storage system

    Science.gov (United States)

    Ahrens, Frederick W.; Kartsounes, George T.

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  15. A high compression crystal growth system

    International Nuclear Information System (INIS)

    Nieman, H.F.; Walton, A.A.; Powell, B.M.; Dolling, G.

    1980-01-01

    This report describes the construction and operating procedure for a high compression crystal growth system, capable of growing single crystals from the fluid phase over the temperature range of 4.2 K to 300 K, at pressures up to 900 MPa. Some experimental results obtained with the system are given for solid β-nitrogen. (auth)

  16. A medical bandage in an Italian Renaissance mummy (Naples, XVI century).

    Science.gov (United States)

    Giuffra, Valentina; Marinozzi, Silvia; Vultaggio, Claudia; Fornaciari, Gino

    2008-01-01

    A dressing was observed on the left arm of the mummy of Mary of Aragon (1503-1568), under her precious Renaissance clothes. It consisted of a true medical bandage, covering a large syphilitic cutaneous ulcer, with a sulphur-embedded wad still in situ. The bandage has a very peculiar shape, rather different from the usual dressings described in the contemporary medical texts: a central rectangular pad, used as compressing appliance, is provided with a sort of pocket containing ivy leaves. The function of the dressing was not only to cover and protect the ulcer, but also to apply a plant drug. This is the first case of ancient medical bandage studied directly on a mummified body.

  17. 30 CFR 77.412 - Compressed air systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compressed air systems. 77.412 Section 77.412... for Mechanical Equipment § 77.412 Compressed air systems. (a) Compressors and compressed-air receivers... involving the pressure system of compressors, receivers, or compressed-air-powered equipment shall not be...

  18. Developing a dynamic control system for mine compressed air networks

    OpenAIRE

    Van Heerden, S.W.; Pelzer, R.; Marais, J.H.

    2014-01-01

    Mines in general, make use of compressed air systems for daily operational activities. Compressed air on mines is traditionally distributed via compressed air ring networks where multiple shafts are supplied with compressed air from an integral system. These compressed air networks make use of a number of compressors feeding the ring from various locations in the network. While these mines have sophisticated control systems to control these compressors, they are not dynamic systems. Compresso...

  19. The dynamics of surge in compression systems

    Indian Academy of Sciences (India)

    is of interest to study compression-system surge to understand its dynamics in order ... Internal problems like compressor going into rotating stall, resulting in loss of ... of water column, was used for mass-flow measurement at the impeller entry.

  20. Waterproof Electronic-Bandage with Tunable Sensitivity for Wearable Strain Sensors.

    Science.gov (United States)

    Jeon, Jun-Young; Ha, Tae-Jun

    2016-02-03

    We demonstrate high-performance wearable electronic-bandage (E-bandage) based on carbon nanotube (CNT)/silver nanoparticle (AgNP) composites covered with flexible media of fluoropolymer-coated polydimethylsiloxane (PDMS) films. The E-bandage can be used for motion-related sensors by directly attaching them to human skin, which achieves a fast and accurate electric response with high sensitivity according to the bending and stretching movements that induce changes in the conductivity. This advance in the E-bandage is realized as a result of the sensitivity that can be achieved by controlling the concentration of AgNPs in CNT pastes and by modifying the device architecture. The fluoropolymer encapsulation with hydrophobic surface characteristics allows for the E-bandage to operate in water and protects it from physical and chemical contact with the daily life conditions of the human skin. The reliability and scalability of the E-bandage as well as the compatibility with conventional microfabrication allow new possibilities to integrate flexible human-interactive nanoelectronics into mobile health-care monitoring systems combined with Internet of things (IoTs).

  1. AIRMaster: Compressed air system audit software

    International Nuclear Information System (INIS)

    Wheeler, G.M.; Bessey, E.G.; McGill, R.D.; Vischer, K.

    1997-01-01

    The project goal was to develop a software tool, AIRMaster, and a methodology for performing compressed air system audits. AIRMaster and supporting manuals are designed for general auditors or plant personnel to evaluate compressed air system operation with simple instrumentation during a short-term audit. AIRMaster provides a systematic approach to compressed air system audits, analyzing collected data, and reporting results. AIRMaster focuses on inexpensive Operation and Maintenance (O and M) measures, such as fixing air leaks and improving controls that can significantly improve performance and reliability of the compressed air system, without significant risk to production. An experienced auditor can perform an audit, analyze collected data, and produce results in 2--3 days. AIRMaster reduces the cost of an audit, thus freeing funds to implement recommendations. The AIRMaster package includes an Audit Manual, Software and User's manual, Analysis Methodology Manual, and a Case Studies summary report. It also includes a Self-Guided Tour booklet to help users quickly screen a plant for efficiency improvement potentials, and an Industrial Compressed Air Systems Energy Efficiency Guidebook. AIRMaster proved to be a fast and effective audit tool. In sever audits AIRMaster identified energy savings of 4,056,000 kWh, or 49.2% of annual compressor energy use, for a cost savings of $152,000. Total implementation costs were $94,700 for a project payback period of 0.6 years. Available airflow increased between 11% and 51% of plant compressor capacity, leading to potential capital benefits from 40% to 230% of first year energy savings

  2. Dynamic mode decomposition for compressive system identification

    Science.gov (United States)

    Bai, Zhe; Kaiser, Eurika; Proctor, Joshua L.; Kutz, J. Nathan; Brunton, Steven L.

    2017-11-01

    Dynamic mode decomposition has emerged as a leading technique to identify spatiotemporal coherent structures from high-dimensional data. In this work, we integrate and unify two recent innovations that extend DMD to systems with actuation and systems with heavily subsampled measurements. When combined, these methods yield a novel framework for compressive system identification, where it is possible to identify a low-order model from limited input-output data and reconstruct the associated full-state dynamic modes with compressed sensing, providing interpretability of the state of the reduced-order model. When full-state data is available, it is possible to dramatically accelerate downstream computations by first compressing the data. We demonstrate this unified framework on simulated data of fluid flow past a pitching airfoil, investigating the effects of sensor noise, different types of measurements (e.g., point sensors, Gaussian random projections, etc.), compression ratios, and different choices of actuation (e.g., localized, broadband, etc.). This example provides a challenging and realistic test-case for the proposed method, and results indicate that the dominant coherent structures and dynamics are well characterized even with heavily subsampled data.

  3. Compressed-air flow control system.

    Science.gov (United States)

    Bong, Ki Wan; Chapin, Stephen C; Pregibon, Daniel C; Baah, David; Floyd-Smith, Tamara M; Doyle, Patrick S

    2011-02-21

    We present the construction and operation of a compressed-air driven flow system that can be used for a variety of microfluidic applications that require rapid dynamic response and precise control of multiple inlet streams. With the use of inexpensive and readily available parts, we describe how to assemble this versatile control system and further explore its utility in continuous- and pulsed-flow microfluidic procedures for the synthesis and analysis of microparticles.

  4. COMPRESS - a computerized reactor safety system

    International Nuclear Information System (INIS)

    Vegh, E.

    1986-01-01

    The computerized reactor safety system, called COMPRESS, provides the following services: scram initiation; safety interlockings; event recording. The paper describes the architecture of the system and deals with reliability problems. A self-testing unit checks permanently the correct operation of the independent decision units. Moreover the decision units are tested by short pulses whether they can initiate a scram. The self-testing is described in detail

  5. Survey on a compressed workweek system

    OpenAIRE

    堀, 忠雄; 林, 光緒; 服部, 敏

    1987-01-01

    A survey was performed on electronics workers with regard to the time - budget differences between permanent day shifts and permanent night shifts in the compressed workweek system. The collection of time - budget data was done in July 1985 and in February 1986. Of the 114 workers in the first survey, 13 were working a 3 night -4 off system (N3O4,), 22 a 3 day - 4 off system (D3O4) 15 a 4 night - 3 off system (N4O3)and 9 a 4 day - 3 off system(D4O3) . In the second survey, 21 of the 79 wo...

  6. Advanced compressed hydrogen fuel storage systems

    International Nuclear Information System (INIS)

    Jeary, B.

    2000-01-01

    Dynetek was established in 1991 by a group of private investors, and since that time efforts have been focused on designing, improving, manufacturing and marketing advanced compressed fuel storage systems. The primary market for Dynetek fuel systems has been Natural Gas, however as the automotive industry investigates the possibility of using hydrogen as the fuel source solution in Alternative Energy Vehicles, there is a growing demand for hydrogen storage on -board. Dynetek is striving to meet the needs of the industry, by working towards developing a fuel storage system that will be efficient, economical, lightweight and eventually capable of storing enough hydrogen to match the driving range of the current gasoline fueled vehicles

  7. Expandable image compression system: A modular approach

    International Nuclear Information System (INIS)

    Ho, B.K.T.; Lo, S.C.; Huang, H.K.

    1986-01-01

    The full-frame bit-allocation algorithm for radiological image compression can achieve an acceptable compression ratio as high as 30:1. It involves two stages of operation: a two-dimensional discrete cosine transform and pixel quantization in the transformed space with pixel depth kept accountable by a bit-allocation table. The cosine transform hardware design took an expandable modular approach based on the VME bus system with a maximum data transfer rate of 48 Mbytes/sec and a microprocessor (Motorola 68000 family). The modules are cascadable and microprogrammable to perform 1,024-point butterfly operations. A total of 18 stages would be required for transforming a 1,000 x 1,000 image. Multiplicative constants and addressing sequences are to be software loaded into the parameter buffers of each stage prior to streaming data through the processor stages. The compression rate for 1K x 1K images is expected to be faster than one image per sec

  8. Use of ultraportable vacuum therapy systems in the treatment of venous leg ulcer.

    Science.gov (United States)

    Cuomo, Roberto; Nisi, Giuseppe; Grimaldi, Luca; Brandi, Cesare; D'Aniello, Carlo

    2017-10-23

    The high incidence of venous leg ulcers and the difficult to give a complete healing involves in an increase of costs for National Health System. Main therapies to obtain a fast healing are compressive bandages, treatment of abnormal venous flow and in-situ-strategies of wound care. Negative pressure therapy does not conventionally used, because these systems not allow the use of compression bandages. Recently the development of ultraportable devices has improved the compliance and the results. Ten patients with venous chronic ulcer on the lower extremities were recruited for this study: all patients had venous leg ulcers from at least one year. We treated the patients with autologous partial thickness skin graft and subsequently we applied NANOVA device included in compressive bandage. We used NANOVA for fourteen days and after we made traditional medications. We submitted a questionnaire to evaluate the impact of dressing and NANOVA device in the quality of life of patients. The device contributed to the formation of granulation tissue and increased the success rate of autologous skin graft without limiting mobility of patient. In addition to this, we have been able to perform compression bandages thanks to small size of this device. Eight ulcers healed within 90 days of medication. We believe that ultraportable negative pressure systems are useful devices for treatment of venous leg ulcers because them allows to realize a compressive bandage without mobility limitations.

  9. Analysis of biogas compression system dynamics

    International Nuclear Information System (INIS)

    Morini, Mirko; Pinelli, Michele; Venturini, Mauro

    2009-01-01

    The use of biogas for energy production has progressively increased in recent years, due to an increasing interest both in agricultural and energy policies of many industrialized countries. Biogas compression by means of natural gas infrastructure seems the most immediate solution, but could also lead to problems due to the different physical properties of the two gases. In this paper, a non-linear one-dimensional modular dynamic model is developed and used for the simulation of compression system transient behavior. The arrangement consists of a main line, where the compressor operates, and an anti-surge control, which consists of a recycle loop activated by a fast acting valve. Different maneuvers (start-up, normal operation, emergency shutdown and operating point variation) are simulated by using two different working fluids (methane and biogas). Simulations prove that the design of the surge protection system should consider the fluid to be elaborated. Moreover, system predisposition to surge increases as the ratio between system volumes and the inertia of the rotating masses increases.

  10. Compressing Data Cube in Parallel OLAP Systems

    Directory of Open Access Journals (Sweden)

    Frank Dehne

    2007-03-01

    Full Text Available This paper proposes an efficient algorithm to compress the cubes in the progress of the parallel data cube generation. This low overhead compression mechanism provides block-by-block and record-by-record compression by using tuple difference coding techniques, thereby maximizing the compression ratio and minimizing the decompression penalty at run-time. The experimental results demonstrate that the typical compression ratio is about 30:1 without sacrificing running time. This paper also demonstrates that the compression method is suitable for Hilbert Space Filling Curve, a mechanism widely used in multi-dimensional indexing.

  11. Two divergent paths: compression vs. non-compression in deep venous thrombosis and post thrombotic syndrome

    Directory of Open Access Journals (Sweden)

    Eduardo Simões Da Matta

    Full Text Available Abstract Use of compression therapy to reduce the incidence of postthrombotic syndrome among patients with deep venous thrombosis is a controversial subject and there is no consensus on use of elastic versus inelastic compression, or on the levels and duration of compression. Inelastic devices with a higher static stiffness index, combine relatively small and comfortable pressure at rest with pressure while standing strong enough to restore the “valve mechanism” generated by plantar flexion and dorsiflexion of the foot. Since the static stiffness index is dependent on the rigidity of the compression system and the muscle strength within the bandaged area, improvement of muscle mass with muscle-strengthening programs and endurance training should be encouraged. Therefore, in the acute phase of deep venous thrombosis events, anticoagulation combined with inelastic compression therapy can reduce the extension of the thrombus. Notwithstanding, prospective studies evaluating the effectiveness of inelastic therapy in deep venous thrombosis and post-thrombotic syndrome are needed.

  12. SHIVA star inductive pulse compression system

    International Nuclear Information System (INIS)

    Reinovsky, R.E.; Baker, W.L.; Chen, Y.G.; Holmes, J.; Lopez, E.

    1983-01-01

    The SHIVA star capacitor bank, a 120 kv parallel bank storing 9.5 mj with a short circuit current of almost 90 ma, at the AFWL is the world's highest energy, fast capacitor bank. The approximately 3 microsecond short circuit risetime is shortened by an inductive store/opening switch power conditioning system in which a total inductance of about 10 nh is charged with 35 ma currents. Electrically exploded conductor (fuse) opening switches are employed to interrupt the current in a few hundred nanoseconds to deliver a fast rising current to the load. The system is in operation at the AFWL and is used for a variety of plasma physics experiments. Performance of the bank and pulse compression system are discussed

  13. Expandable image compression system: A modular approach

    International Nuclear Information System (INIS)

    Ho, B.K.T.; Chan, K.K.; Ishimitsu, Y.; Lo, S.C.; Huang, H.K.

    1987-01-01

    The full-frame bit allocation algorithm for radiological image compression developed in the authors' laboratory can achieve compression ratios as high as 30:1. The software development and clinical evaluation of this algorithm has been completed. It involves two stages of operations: a two-dimensional discrete cosine transform and pixel quantization in the transform space with pixel depth kept accountable by a bit allocation table. Their design took an expandable modular approach based on the VME bus system which has a maximum data transfer rate of 48 Mbytes per second and a Motorola 68020 microprocessor as the master controller. The transform modules are based on advanced digital signal processor (DSP) chips microprogrammed to perform fast cosine transforms. Four DSP's built into a single-board transform module can process an 1K x 1K image in 1.7 seconds. Additional transform modules working in parallel can be added if even greater speeds are desired. The flexibility inherent in the microcode extends the capabilities of the system to incorporate images of variable sizes. Their design allows for a maximum image size of 2K x 2K

  14. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-06-29

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  15. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    Science.gov (United States)

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-06-01

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  16. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds.

    Science.gov (United States)

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-06-29

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  17. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  18. Image compression-encryption scheme based on hyper-chaotic system and 2D compressive sensing

    Science.gov (United States)

    Zhou, Nanrun; Pan, Shumin; Cheng, Shan; Zhou, Zhihong

    2016-08-01

    Most image encryption algorithms based on low-dimensional chaos systems bear security risks and suffer encryption data expansion when adopting nonlinear transformation directly. To overcome these weaknesses and reduce the possible transmission burden, an efficient image compression-encryption scheme based on hyper-chaotic system and 2D compressive sensing is proposed. The original image is measured by the measurement matrices in two directions to achieve compression and encryption simultaneously, and then the resulting image is re-encrypted by the cycle shift operation controlled by a hyper-chaotic system. Cycle shift operation can change the values of the pixels efficiently. The proposed cryptosystem decreases the volume of data to be transmitted and simplifies the keys distribution simultaneously as a nonlinear encryption system. Simulation results verify the validity and the reliability of the proposed algorithm with acceptable compression and security performance.

  19. Compression of Short Text on Embedded Systems

    DEFF Research Database (Denmark)

    Rein, S.; Gühmann, C.; Fitzek, Frank

    2006-01-01

    The paper details a scheme for lossless compression of a short data series larger than 50 bytes. The method uses arithmetic coding and context modelling with a low-complexity data model. A data model that takes 32 kBytes of RAM already cuts the data size in half. The compression scheme just takes...

  20. Compression therapy in patients with venous leg ulcers.

    Science.gov (United States)

    Dissemond, Joachim; Assenheimer, Bernd; Bültemann, Anke; Gerber, Veronika; Gretener, Silvia; Kohler-von Siebenthal, Elisabeth; Koller, Sonja; Kröger, Knut; Kurz, Peter; Läuchli, Severin; Münter, Christian; Panfil, Eva-Maria; Probst, Sebastian; Protz, Kerstin; Riepe, Gunnar; Strohal, Robert; Traber, Jürg; Partsch, Hugo

    2016-11-01

    Wund-D.A.CH. is the umbrella organization of the various wound care societies in German-speaking countries. The present consensus paper on practical aspects pertinent to compression therapy in patients with venous leg ulcers was developed by experts from Germany, Austria, and Switzerland. In Europe, venous leg ulcers rank among the most common causes of chronic wounds. Apart from conservative and interventional wound and vein treatment, compression therapy represents the basis of all other therapeutic strategies. To that end, there are currently a wide variety of materials and systems available. While especially short-stretch bandages or multicomponent systems should be used in the initial decongestion phase, ulcer stocking systems are recommended for the subsequent maintenance phase. Another - to date, far less common - alternative are adaptive Velcro bandage systems. Medical compression stockings have proven particularly beneficial in the prevention of ulcer recurrence. The large number of treatment options currently available enables therapists to develop therapeutic concepts geared towards their patients' individual needs and abilities, thus resulting in good acceptance and adherence. Compression therapy plays a crucial role in the treatment of patients with venous leg ulcers. In recent years, a number of different treatment options have become available, their use and application differing among German-speaking countries. The present expert consensus is therefore meant to outline concrete recommendations for routine implementation of compression therapy in patients with venous leg ulcers. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  1. A new compressed air energy storage refrigeration system

    International Nuclear Information System (INIS)

    Wang Shenglong; Chen Guangming; Fang Ming; Wang Qin

    2006-01-01

    In this study, a new compressed air energy storage (CAES) refrigeration system is proposed for electrical power load shifting application. It is a combination of a gas refrigeration cycle and a vapor compression refrigeration cycle. Thermodynamic calculations are conducted to investigate the performance of this system. Economic analysis is performed to study the operating cost of the system, and comparison is made with a vapor compression refrigeration system and an ice storage refrigeration system. The results indicate that the CAES refrigeration system has the advantages of simple structure, high efficiency and low operating cost

  2. A checkpoint compression study for high-performance computing systems

    Energy Technology Data Exchange (ETDEWEB)

    Ibtesham, Dewan [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Computer Science; Ferreira, Kurt B. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Scalable System Software Dept.; Arnold, Dorian [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Computer Science

    2015-02-17

    As high-performance computing systems continue to increase in size and complexity, higher failure rates and increased overheads for checkpoint/restart (CR) protocols have raised concerns about the practical viability of CR protocols for future systems. Previously, compression has proven to be a viable approach for reducing checkpoint data volumes and, thereby, reducing CR protocol overhead leading to improved application performance. In this article, we further explore compression-based CR optimization by exploring its baseline performance and scaling properties, evaluating whether improved compression algorithms might lead to even better application performance and comparing checkpoint compression against and alongside other software- and hardware-based optimizations. Our results highlights are: (1) compression is a very viable CR optimization; (2) generic, text-based compression algorithms appear to perform near optimally for checkpoint data compression and faster compression algorithms will not lead to better application performance; (3) compression-based optimizations fare well against and alongside other software-based optimizations; and (4) while hardware-based optimizations outperform software-based ones, they are not as cost effective.

  3. Acceptance Test Report for 241-U compressed air system

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1994-01-01

    This Acceptance Test Report (ATR) documents the results of acceptance testing of a newly upgraded compressed air system at 241-U Farm. The system was installed and the test successfully performed under work package 2W-92-01027

  4. Performance of target detection algorithm in compressive sensing miniature ultraspectral imaging compressed sensing system

    Science.gov (United States)

    Gedalin, Daniel; Oiknine, Yaniv; August, Isaac; Blumberg, Dan G.; Rotman, Stanley R.; Stern, Adrian

    2017-04-01

    Compressive sensing theory was proposed to deal with the high quantity of measurements demanded by traditional hyperspectral systems. Recently, a compressive spectral imaging technique dubbed compressive sensing miniature ultraspectral imaging (CS-MUSI) was presented. This system uses a voltage controlled liquid crystal device to create multiplexed hyperspectral cubes. We evaluate the utility of the data captured using the CS-MUSI system for the task of target detection. Specifically, we compare the performance of the matched filter target detection algorithm in traditional hyperspectral systems and in CS-MUSI multiplexed hyperspectral cubes. We found that the target detection algorithm performs similarly in both cases, despite the fact that the CS-MUSI data is up to an order of magnitude less than that in conventional hyperspectral cubes. Moreover, the target detection is approximately an order of magnitude faster in CS-MUSI data.

  5. Improving compressed air system performance: A sourcebook for industry

    OpenAIRE

    Mckane, Aimee T.

    2003-01-01

    Compressed air is used widely throughout industry and is often considered the "fourth utility" at many facilities. Almost every industrial plant, from a small machine shop to an immense pulp and paper mill, has some type of compressed air system. In many cases, the compressed air system is so vital that the facility cannot operate without it. Plant air compressor systems can vary in size from a small unit of 5 horsepower (hp) to huge systems with more than 50,000 hp. In many industrial facili...

  6. Refrigerants for Vapour Compression Refrigeration Systems

    Indian Academy of Sciences (India)

    c) Low compression ratio to give high volumetric efficiency and low power ... The normal boiling point5 is also a good indicator of the critical temperature since .... than a few minutes during maintenance and service activities. Freezing point of ...

  7. Intelligent transportation systems data compression using wavelet decomposition technique.

    Science.gov (United States)

    2009-12-01

    Intelligent Transportation Systems (ITS) generates massive amounts of traffic data, which posts : challenges for data storage, transmission and retrieval. Data compression and reconstruction technique plays an : important role in ITS data procession....

  8. Investigation on wind energy-compressed air power system.

    Science.gov (United States)

    Jia, Guang-Zheng; Wang, Xuan-Yin; Wu, Gen-Mao

    2004-03-01

    Wind energy is a pollution free and renewable resource widely distributed over China. Aimed at protecting the environment and enlarging application of wind energy, a new approach to application of wind energy by using compressed air power to some extent instead of electricity put forward. This includes: explaining the working principles and characteristics of the wind energy-compressed air power system; discussing the compatibility of wind energy and compressor capacity; presenting the theoretical model and computational simulation of the system. The obtained compressor capacity vs wind power relationship in certain wind velocity range can be helpful in the designing of the wind power-compressed air system. Results of investigations on the application of high-pressure compressed air for pressure reduction led to conclusion that pressure reduction with expander is better than the throttle regulator in energy saving.

  9. Design of a Hydraulic Motor System Driven by Compressed Air

    OpenAIRE

    Shaw, Dein; Yu, Jyun-Jhe; Chieh, Cheng

    2013-01-01

    This paper presents the design of a highly efficient pneumatic motor system. The air engine is currently the most generally used device to convert potential energy of compressed air into mechanical energy. However, the efficiency of the air engines is too low to provide sufficient operating range for the vehicle. In this study, the energy contained in compressed air/pressurized hydraulic oil is transformed by a hydraulic motor to mechanical energy to enhance the efficiency of using air power....

  10. A bandage contact lens prevents extrusion of ocular contents.

    Science.gov (United States)

    Ramjiani, Vipul; Fearnley, Thomas; Tan, Jennifer

    2016-02-01

    A 76 year old male presents with a corneal perforation in a phthisical eye. Definitive treatment in the form of an evisceration was delayed by 38 days. During this period a bandage contact lens prevented extrusion of ocular contents through an enlarging corneal perforation. This case demonstrates that a bandage contact lens can be effective in the immediate management of large corneal perforations whilst awaiting urgent definitive treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    OpenAIRE

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can...

  12. On system behaviour using complex networks of a compression algorithm

    Science.gov (United States)

    Walker, David M.; Correa, Debora C.; Small, Michael

    2018-01-01

    We construct complex networks of scalar time series using a data compression algorithm. The structure and statistics of the resulting networks can be used to help characterize complex systems, and one property, in particular, appears to be a useful discriminating statistic in surrogate data hypothesis tests. We demonstrate these ideas on systems with known dynamical behaviour and also show that our approach is capable of identifying behavioural transitions within electroencephalogram recordings as well as changes due to a bifurcation parameter of a chaotic system. The technique we propose is dependent on a coarse grained quantization of the original time series and therefore provides potential for a spatial scale-dependent characterization of the data. Finally the method is as computationally efficient as the underlying compression algorithm and provides a compression of the salient features of long time series.

  13. Data compression systems for home-use digital video recording

    NARCIS (Netherlands)

    With, de P.H.N.; Breeuwer, M.; van Grinsven, P.A.M.

    1992-01-01

    The authors focus on image data compression techniques for digital recording. Image coding for storage equipment covers a large variety of systems because the applications differ considerably in nature. Video coding systems suitable for digital TV and HDTV recording and digital electronic still

  14. Numerical approach to solar ejector-compression refrigeration system

    Directory of Open Access Journals (Sweden)

    Zheng Hui-Fan

    2016-01-01

    Full Text Available A model was established for solar ejector-compression refrigeration system. The influence of generator temperature, middle-temperature, and evaporator temperature on the performance of the refrigerant system was analyzed. An optimal generator temperature is found for maximal energy efficiency ratio and minimal power consumption.

  15. Improving Compressed Air System Performance: A Sourcebook for Industry

    Energy Technology Data Exchange (ETDEWEB)

    2003-11-01

    NREL will produce this sourcebook for DOE's Industrial Technologies Office as part of a series of documents on industrial energy equipment. The sourcebook is a reference for industrial compressed air system users, outlining opportunities to improve system efficiency.

  16. Delivery of compression therapy for venous leg ulcers.

    Science.gov (United States)

    Zarchi, Kian; Jemec, Gregor B E

    2014-07-01

    Despite the documented effect of compression therapy in clinical studies and its widespread prescription, treatment of venous leg ulcers is often prolonged and recurrence rates high. Data on provided compression therapy are limited. To assess whether home care nurses achieve adequate subbandage pressure when treating patients with venous leg ulcers and the factors that predict the ability to achieve optimal pressure. We performed a cross-sectional study from March 1, 2011, through March 31, 2012, in home care centers in 2 Danish municipalities. Sixty-eight home care nurses who managed wounds in their everyday practice were included. Participant-masked measurements of subbandage pressure achieved with an elastic, long-stretch, single-component bandage; an inelastic, short-stretch, single-component bandage; and a multilayer, 2-component bandage, as well as, association between achievement of optimal pressure and years in the profession, attendance at wound care educational programs, previous work experience, and confidence in bandaging ability. A substantial variation in the exerted pressure was found: subbandage pressures ranged from 11 mm Hg exerted by an inelastic bandage to 80 mm Hg exerted by a 2-component bandage. The optimal subbandage pressure range, defined as 30 to 50 mm Hg, was achieved by 39 of 62 nurses (63%) applying the 2-component bandage, 28 of 68 nurses (41%) applying the elastic bandage, and 27 of 68 nurses (40%) applying the inelastic bandage. More than half the nurses applying the inelastic (38 [56%]) and elastic (36 [53%]) bandages obtained pressures less than 30 mm Hg. At best, only 17 of 62 nurses (27%) using the 2-component bandage achieved subbandage pressure within the range they aimed for. In this study, none of the investigated factors was associated with the ability to apply a bandage with optimal pressure. This study demonstrates the difficulty of achieving the desired subbandage pressure and indicates that a substantial proportion of

  17. Applications Guide for Compressed Air Systems

    National Research Council Canada - National Science Library

    Lin, Mike

    2001-01-01

    .... Although CA systems are a very convenient power source, they are not cheap to operate. However, nearly all industrial plants can realize from 25 to 40 percent savings on the power costs for the CA system without additional capital expenditures...

  18. Compressing Control System Data for Efficient Storage and Retrieval

    International Nuclear Information System (INIS)

    Christopher Larrieu

    2003-01-01

    The controls group at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), acquires multiple terabytes of EPICS control system data per year via CZAR, its new archiving system. By heuristically applying a combination of rudimentary compression techniques, in conjunction with several specialized data transformations and algorithms, the CZAR storage engine reduces the size of this data by approximately 88 percent, without any loss of information. While the compression process requires significant memory and processor time, the decompression routine suffers only slightly in this regard

  19. Stability of Bifurcating Stationary Solutions of the Artificial Compressible System

    Science.gov (United States)

    Teramoto, Yuka

    2018-02-01

    The artificial compressible system gives a compressible approximation of the incompressible Navier-Stokes system. The latter system is obtained from the former one in the zero limit of the artificial Mach number ɛ which is a singular limit. The sets of stationary solutions of both systems coincide with each other. It is known that if a stationary solution of the incompressible system is asymptotically stable and the velocity field of the stationary solution satisfies an energy-type stability criterion, then it is also stable as a solution of the artificial compressible one for sufficiently small ɛ . In general, the range of ɛ shrinks when the spectrum of the linearized operator for the incompressible system approaches to the imaginary axis. This can happen when a stationary bifurcation occurs. It is proved that when a stationary bifurcation from a simple eigenvalue occurs, the range of ɛ can be taken uniformly near the bifurcation point to conclude the stability of the bifurcating solution as a solution of the artificial compressible system.

  20. Lossy image compression for digital medical imaging systems

    Science.gov (United States)

    Wilhelm, Paul S.; Haynor, David R.; Kim, Yongmin; Nelson, Alan C.; Riskin, Eve A.

    1990-07-01

    Image compression at rates of 10:1 or greater could make PACS much more responsive and economically attractive. This paper describes a protocol for subjective and objective evaluation of the fidelity of compressed/decompressed images to the originals and presents the results ofits application to four representative and promising compression methods. The methods examined are predictive pruned tree-structured vector quantization, fractal compression, the discrete cosine transform with equal weighting of block bit allocation, and the discrete cosine transform with human visual system weighting of block bit allocation. Vector quantization is theoretically capable of producing the best compressed images, but has proven to be difficult to effectively implement. It has the advantage that it can reconstruct images quickly through a simple lookup table. Disadvantages are that codebook training is required, the method is computationally intensive, and achieving the optimum performance would require prohibitively long vector dimensions. Fractal compression is a relatively new compression technique, but has produced satisfactory results while being computationally simple. It is fast at both image compression and image reconstruction. Discrete cosine iransform techniques reproduce images well, but have traditionally been hampered by the need for intensive computing to compress and decompress images. A protocol was developed for side-by-side observer comparison of reconstructed images with originals. Three 1024 X 1024 CR (Computed Radiography) images and two 512 X 512 X-ray CT images were viewed at six bit rates (0.2, 0.4, 0.6, 0.9, 1.2, and 1.5 bpp for CR, and 1.0, 1.3, 1.6, 1.9, 2.2, 2.5 bpp for X-ray CT) by nine radiologists at the University of Washington Medical Center. The CR images were viewed on a Pixar II Megascan (2560 X 2048) monitor and the CT images on a Sony (1280 X 1024) monitor. The radiologists' subjective evaluations of image fidelity were compared to

  1. Offshore compression system design for low cost high and reliability

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Carlos J. Rocha de O.; Carrijo Neto, Antonio Dias; Cordeiro, Alexandre Franca [Chemtech Engineering Services and Software Ltd., Rio de Janeiro, RJ (Brazil). Special Projects Div.], Emails: antonio.carrijo@chemtech.com.br, carlos.rocha@chemtech.com.br, alexandre.cordeiro@chemtech.com.br

    2010-07-01

    In the offshore oil fields, the oil streams coming from the wells usually have significant amounts of gas. This gas is separated at low pressure and has to be compressed to the export pipeline pressure, usually at high pressure to reduce the needed diameter of the pipelines. In the past, this gases where flared, but nowadays there are a increasing pressure for the energy efficiency improvement of the oil rigs and the use of this gaseous fraction. The most expensive equipment of this kind of plant are the compression and power generation systems, being the second a strong function of the first, because the most power consuming equipment are the compressors. For this reason, the optimization of the compression system in terms of efficiency and cost are determinant to the plant profit. The availability of the plants also have a strong influence in the plant profit, specially in gas fields where the products have a relatively low aggregated value, compared to oil. Due this, the third design variable of the compression system becomes the reliability. As high the reliability, larger will be the plant production. The main ways to improve the reliability of compression system are the use of multiple compression trains in parallel, in a 2x50% or 3x50% configuration, with one in stand-by. Such configurations are possible and have some advantages and disadvantages, but the main side effect is the increase of the cost. This is the offshore common practice, but that does not always significantly improve the plant availability, depending of the previous process system. A series arrangement and a critical evaluation of the overall system in some cases can provide a cheaper system with equal or better performance. This paper shows a case study of the procedure to evaluate a compression system design to improve the reliability but without extreme cost increase, balancing the number of equipment, the series or parallel arrangement, and the driver selection. Two cases studies will be

  2. Safety considerations for compressed hydrogen storage systems

    International Nuclear Information System (INIS)

    Gleason, D.

    2006-01-01

    An overview of the safety considerations for various hydrogen storage options, including stationary, vehicle storage, and mobile refueling technologies. Indications of some of the challenges facing the industry as the demand for hydrogen fuel storage systems increases. (author)

  3. A design approach for systems based on magnetic pulse compression

    International Nuclear Information System (INIS)

    Praveen Kumar, D. Durga; Mitra, S.; Senthil, K.; Sharma, D. K.; Rajan, Rehim N.; Sharma, Archana; Nagesh, K. V.; Chakravarthy, D. P.

    2008-01-01

    A design approach giving the optimum number of stages in a magnetic pulse compression circuit and gain per stage is given. The limitation on the maximum gain per stage is discussed. The total system volume minimization is done by considering the energy storage capacitor volume and magnetic core volume at each stage. At the end of this paper, the design of a magnetic pulse compression based linear induction accelerator of 200 kV, 5 kA, and 100 ns with a repetition rate of 100 Hz is discussed with its experimental results

  4. Compressed gas system operates semitrailer brakes during winching operation

    Science.gov (United States)

    Tupper, W. E.

    1964-01-01

    To move van-type semi-trailers into and out of confined spaces, an auxiliary braking system is mounted on a standard dolly converter. Compressed nitrogen is used to actuate the brakes which are used in conjunction with a power winch.

  5. Choice of compressed air fed system of a uranium mine

    International Nuclear Information System (INIS)

    Li Congkui; Lei Zeyong

    2006-01-01

    The selection of compressed air fed system in a uranium mine is discussed. The research indicates that the movable air compressor is better than the fixed one in energy saving, once capital cost and operational cost when it is applied in an underground uranium mine. (authors)

  6. A materials test system for static compression at elevated temperatures

    Science.gov (United States)

    Korellis, J. S.; Steinhaus, C. A.; Totten, J. J.

    1992-06-01

    This report documents modifications to our existing computer-controlled compression testing system to allow elevated temperature testing in an evacuated environment. We have adopted an 'inverse' design configuration where the evacuated test volume is located within the induction heating coil, eliminating the expense and minimizing the evacuation time of a much larger traditional vacuum chamber.

  7. Dynamic model including piping acoustics of a centrifugal compression system

    NARCIS (Netherlands)

    Helvoirt, van J.; Jager, de A.G.

    2007-01-01

    This paper deals with low frequency pulsation phenomena in full-scale centrifugal compression systems associated with compressor surge. The Greitzer lumped parameter model is applied to describe the dynamic behavior of an industrial compressor test rig and experimental evidence is provided for the

  8. Compressed air system audit in a chemical company

    Energy Technology Data Exchange (ETDEWEB)

    Radgen, P. [Fraunhofer ISI, Karlsruhe (Germany)

    2005-07-01

    This paper describes the results achieved during a compressed air system audit at a chemical company in Switzerland. The aim of the audit conducted in Muttenz at the site of Clariant Schweiz AG was to analyse the installed compressed air system and its operation in order to identify energy and cost saving potentials. Because there was measurement equipment already installed, it was not necessary to install a new meter. Instead the existing data had to be extracted from the controlled system and regrouped for the analysis. Aggregated data for 2003 and 2004 and a set of detailed data acquired in the course of one week were used for the analysis. The audit identified a number of measures to improve the compressed air system, but had to conclude that the saving potentials at this site are below average. The audit included the compressors, the air treatment and air distribution up to production or storage buildings. The saving potential identified was quantified as about 300 000 kWh/a, or 13.3% of the compressed air energy demand. The cost savings were calculated to be around 41 852 Swiss Franks. (orig.)

  9. Use of compressed-air storage systems; Einsatz von Druckluftspeichersystemen

    Energy Technology Data Exchange (ETDEWEB)

    Cyphely, I.; Rufer, A.; Brueckmann, Ph.; Menhardt, W.; Reller, A.

    2004-07-01

    This final report issued by the Swiss Federal Office of Energy (SFOE) looks at the use of compressed air as a means of storing energy. Historical aspects are listed and compressed-air storage as an alternative to current ideas that use electrolysis and hydrogen storage is discussed. The storage efficiency advantages of compressed-air storage is stressed and the possibilities it offers for compensating the stochastic nature of electricity production from renewable energy sources are discussed. The so-called BOP (Battery with Oil-hydraulics and Pneumatics) principle for the storage of electricity is discussed and its function is described. The advantages offered by such a system are listed and the development focus necessary is discussed.

  10. Analytical modeling of wet compression of gas turbine systems

    International Nuclear Information System (INIS)

    Kim, Kyoung Hoon; Ko, Hyung-Jong; Perez-Blanco, Horacio

    2011-01-01

    Evaporative gas turbine cycles (EvGT) are of importance to the power generation industry because of the potential of enhanced cycle efficiencies with moderate incremental cost. Humidification of the working fluid to result in evaporative cooling during compression is a key operation in these cycles. Previous simulations of this operation were carried out via numerical integration. The present work is aimed at modeling the wet-compression process with approximate analytical solutions instead. A thermodynamic analysis of the simultaneous heat and mass transfer processes that occur during evaporation is presented. The transient behavior of important variables in wet compression such as droplet diameter, droplet mass, gas and droplet temperature, and evaporation rate is investigated. The effects of system parameters on variables such as droplet evaporation time, compressor outlet temperature and input work are also considered. Results from this work exhibit good agreement with those of previous numerical work.

  11. Optimal design of compressed air energy storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, F. W.; Sharma, A.; Ragsdell, K. M.

    1979-01-01

    Compressed air energy storage (CAES) power systems are currently being considered by various electric utilities for load-leveling applications. Models of CAES systems which employ natural underground aquifer formations, and present an optimal design methodology which demonstrates their economic viability are developed. This approach is based upon a decomposition of the CAES plant and utility grid system into three partially-decoupled subsystems. Numerical results are given for a plant employing the Media, Illinois Galesville aquifer formation.

  12. Compressive Information Extraction: A Dynamical Systems Approach

    Science.gov (United States)

    2016-01-24

    significantly benefit society. Systems endowed with activity analysis capabilities can prevent crime, allow elderly people to continue living independently...keynote speaker at the 2014 IEEE International Conference on Distributed Smart Cameras. 9 2.5 Transitions The theoretical framework developed under...FBI Deputy Director, June 2013) and the Hon. Theresa May (U.K. Home Secretary, Sept. 2014). It was also covered in a N.Y. Times article that appeared

  13. Quasilinear Hyperbolic Systems, Compressible Flows, and Waves

    CERN Document Server

    Sharma, Vishnu D

    2010-01-01

    Filled with practical examples, this book presents a self-contained discussion of quasilinear hyperbolic equations and systems with applications. It emphasizes nonlinear theory and introduces some of the most active research in the field. The author elucidates all necessary mathematical concepts in the first three chapters, including an introduction to general wave propagation problems. He highlights the application of various approaches, such as singular surface theory, asymptotic methods, and self-similarity, to solve practical physical problems from areas, including gasdynamics, radiation g

  14. Harmonic analysis in integrated energy system based on compressed sensing

    International Nuclear Information System (INIS)

    Yang, Ting; Pen, Haibo; Wang, Dan; Wang, Zhaoxia

    2016-01-01

    Highlights: • We propose a harmonic/inter-harmonic analysis scheme with compressed sensing theory. • Property of sparseness of harmonic signal in electrical power system is proved. • The ratio formula of fundamental and harmonic components sparsity is presented. • Spectral Projected Gradient-Fundamental Filter reconstruction algorithm is proposed. • SPG-FF enhances the precision of harmonic detection and signal reconstruction. - Abstract: The advent of Integrated Energy Systems enabled various distributed energy to access the system through different power electronic devices. The development of this has made the harmonic environment more complex. It needs low complexity and high precision of harmonic detection and analysis methods to improve power quality. To solve the shortages of large data storage capacities and high complexity of compression in sampling under the Nyquist sampling framework, this research paper presents a harmonic analysis scheme based on compressed sensing theory. The proposed scheme enables the performance of the functions of compressive sampling, signal reconstruction and harmonic detection simultaneously. In the proposed scheme, the sparsity of the harmonic signals in the base of the Discrete Fourier Transform (DFT) is numerically calculated first. This is followed by providing a proof of the matching satisfaction of the necessary conditions for compressed sensing. The binary sparse measurement is then leveraged to reduce the storage space in the sampling unit in the proposed scheme. In the recovery process, the scheme proposed a novel reconstruction algorithm called the Spectral Projected Gradient with Fundamental Filter (SPG-FF) algorithm to enhance the reconstruction precision. One of the actual microgrid systems is used as simulation example. The results of the experiment shows that the proposed scheme effectively enhances the precision of harmonic and inter-harmonic detection with low computing complexity, and has good

  15. Design of a Hydraulic Motor System Driven by Compressed Air

    Directory of Open Access Journals (Sweden)

    Jyun-Jhe Yu

    2013-06-01

    Full Text Available This paper presents the design of a highly efficient pneumatic motor system. The air engine is currently the most generally used device to convert potential energy of compressed air into mechanical energy. However, the efficiency of the air engines is too low to provide sufficient operating range for the vehicle. In this study, the energy contained in compressed air/pressurized hydraulic oil is transformed by a hydraulic motor to mechanical energy to enhance the efficiency of using air power. To evaluate the theoretical efficiency, the principle of balance of energy is applied. The theoretical efficiency of converting air into hydraulic energy is found to be a function of pressure; thus, the maximum converting efficiency can be determined. To confirm the theoretical evaluation, a prototype of the pneumatic hydraulic system is built. The experiment verifies that the theoretical evaluation of the system efficiency is reasonable, and that the layout of the system is determined by the results of theoretical evaluation.

  16. CLASSIFICATION OF THE MGR SITE COMPRESSED AIR SYSTEM

    International Nuclear Information System (INIS)

    J.A. Ziegler

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) site compressed air system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  17. VenUS I: a randomised controlled trial of two types of bandage for treating venous leg ulcers.

    Science.gov (United States)

    Iglesias, C; Nelson, E A; Cullum, N A; Torgerson, D J

    2004-07-01

    To compare the clinical and cost-effectiveness of two different compression bandages for the healing of venous leg ulcers. A pragmatic, randomised controlled trial with an economic evaluation. Community, district nurse-led services; community leg ulcer clinics; hospital leg ulcer clinics with community outreach. A range of urban and rural settings in England and Scotland. Patients with a venous leg ulcer of at least 1-week's duration, at least 1 cm in length or width and an ankle:brachial pressure index of at least 0.8. The four-layer bandage (4LB) (which is multilayer elastic compression) compared with the short-stretch bandage (SSB) (multilayer, inelastic compression). The primary end-point was complete healing of all the ulcers on the trial leg. Secondary outcomes were the proportion of patients healed at 12 and 24 weeks, rate of recurrence, costs of leg ulcer treatment and quality of life. Between April 1999 and December 2000 the trial recruited 387 people aged from 23 to 97 years at trial entry. The majority of patients in this trial (82%; 316/387) had a reference ulcer of area bandage groups, the distribution of the cumulative times to healing of individuals in the two trial groups was compared using the log-rank test. The difference in the distribution of cumulative healing times between the individuals in the two groups was not statistically significant at the 5% level. Adjusting for the effects of variables which may influence healing (centre, baseline ulcer area, duration, episodes, ankle mobility, weight) in a Cox proportional hazards model, a statistically significant treatment effect in favour of the 4LB was identified. At any point in time, the probability of healing for individuals in the SSB treatment arm is significantly lower than that for people treated with the 4LB. Our base case economic analysis showed that the 4LB is the dominant strategy, that is, it is associated with a greater health benefit and lower costs than the SSB, although the

  18. System using data compression and hashing adapted for use for multimedia encryption

    Science.gov (United States)

    Coffland, Douglas R [Livermore, CA

    2011-07-12

    A system and method is disclosed for multimedia encryption. Within the system of the present invention, a data compression module receives and compresses a media signal into a compressed data stream. A data acquisition module receives and selects a set of data from the compressed data stream. And, a hashing module receives and hashes the set of data into a keyword. The method of the present invention includes the steps of compressing a media signal into a compressed data stream; selecting a set of data from the compressed data stream; and hashing the set of data into a keyword.

  19. Compression for the management of venous leg ulcers: which material do we have?

    Science.gov (United States)

    Partsch, Hugo

    2014-05-01

    Compression therapy is the most important basic treatment modality in venous leg ulcers. The review focusses on the materials which are used: 1. Compression bandages, 2. Compression stockings, 3. Self-adjustable Velcro-devices, 4. Compression pumps, 5. Hybrid devices. Compression bandages, usually applied by trained staff, provide a wide spectrum of materials with different elastic properties. To make bandaging easier, safer and more effective, most modern bandages combine different material components. Self-management of venous ulcers has become feasible by introducing double compression stockings ("ulcer kits") and self-adjustable Velcro devices. Compression pumps can be used as adjunctive measures, especially for patients with restricted mobility. The combination of sustained and intermittent compression ("hybrid device") is a promising new tool. The interface pressure corresponding to the dosage of compression therapy determines the hemodynamic efficacy of each device. In order to reduce ambulatory venous hypertension compression pressures of more than 50 mm Hg in the upright position are desirable. At the same time pressure should be lower in the resting position in order to be tolerated. This prerequisite may be fulfilled by using inelastic, short stretch material including multicomponent bandages and cohesive surfaces, all characterized by high stiffness. Such materials do not give way when calf muscles contract during walking which leads to high peaks of interface pressure ("massaging effect"). © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Quantum thermostatted disordered systems and sensitivity under compression

    Science.gov (United States)

    Vanzan, Tommaso; Rondoni, Lamberto

    2018-03-01

    A one-dimensional quantum system with off diagonal disorder, consisting of a sample of conducting regions randomly interspersed within potential barriers is considered. Results mainly concerning the large N limit are presented. In particular, the effect of compression on the transmission coefficient is investigated. A numerical method to simulate such a system, for a physically relevant number of barriers, is proposed. It is shown that the disordered model converges to the periodic case as N increases, with a rate of convergence which depends on the disorder degree. Compression always leads to a decrease of the transmission coefficient which may be exploited to design nano-technological sensors. Effective choices for the physical parameters to improve the sensitivity are provided. Eventually large fluctuations and rate functions are analysed.

  1. Uniqueness of rarefaction waves in multidimensional compressible Euler system

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Kreml, Ondřej

    2015-01-01

    Roč. 12, č. 3 (2015), s. 489-499 ISSN 0219-8916 R&D Projects: GA ČR GA13-00522S EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : compressible Euler system * uniqueness * rarefaction wave * Riemann problem Subject RIV: BA - General Mathematics Impact factor: 0.556, year: 2015 http://www.worldscientific.com/doi/abs/10.1142/S0219891615500149

  2. Non-invasive transdermal two-dimensional mapping of cutaneous oxygenation with a rapid-drying liquid bandage.

    Science.gov (United States)

    Li, Zongxi; Roussakis, Emmanuel; Koolen, Pieter G L; Ibrahim, Ahmed M S; Kim, Kuylhee; Rose, Lloyd F; Wu, Jesse; Nichols, Alexander J; Baek, Yunjung; Birngruber, Reginald; Apiou-Sbirlea, Gabriela; Matyal, Robina; Huang, Thomas; Chan, Rodney; Lin, Samuel J; Evans, Conor L

    2014-11-01

    Oxygen plays an important role in wound healing, as it is essential to biological functions such as cell proliferation, immune responses and collagen synthesis. Poor oxygenation is directly associated with the development of chronic ischemic wounds, which affect more than 6 million people each year in the United States alone at an estimated cost of $25 billion. Knowledge of oxygenation status is also important in the management of burns and skin grafts, as well as in a wide range of skin conditions. Despite the importance of the clinical determination of tissue oxygenation, there is a lack of rapid, user-friendly and quantitative diagnostic tools that allow for non-disruptive, continuous monitoring of oxygen content across large areas of skin and wounds to guide care and therapeutic decisions. In this work, we describe a sensitive, colorimetric, oxygen-sensing paint-on bandage for two-dimensional mapping of tissue oxygenation in skin, burns, and skin grafts. By embedding both an oxygen-sensing porphyrin-dendrimer phosphor and a reference dye in a liquid bandage matrix, we have created a liquid bandage that can be painted onto the skin surface and dries into a thin film that adheres tightly to the skin or wound topology. When captured by a camera-based imaging device, the oxygen-dependent phosphorescence emission of the bandage can be used to quantify and map both the pO2 and oxygen consumption of the underlying tissue. In this proof-of-principle study, we first demonstrate our system on a rat ischemic limb model to show its capabilities in sensing tissue ischemia. It is then tested on both ex vivo and in vivo porcine burn models to monitor the progression of burn injuries. Lastly, the bandage is applied to an in vivo porcine graft model for monitoring the integration of full- and partial-thickness skin grafts.

  3. Desalination using spray tower and vapour compression refrigeration system

    International Nuclear Information System (INIS)

    Sathish Kumar, S.; Mani, A.

    2006-01-01

    A desalination system using a spray tower and Vapour Compression Refrigeration (VCR) system is proposed for obtaining fresh water from brackish water. In the spray tower, simultaneous heat and mass transfer take place between the brackish water and air, which results in the evaporation of the brackish water and humidification of the air. Fresh water is obtained from the humidified air by condensing the water vapour using a VCR system. Parametric studies were carried out to study the effect of various operational parameters on the fresh water production rate. (author)

  4. Jamming by compressing a system of granular crosses

    Science.gov (United States)

    Zheng, Hu; Wang, Dong; Barés, Jonathan; Behringer, Robert

    2017-06-01

    A disordered stress-free granular packing can be jammed, transformed into a mechanically rigid structure, by increasing the density of particles or by applying shear deformation. The jamming behavior of systems made of 2D circular discs has been investigated in detail, but very little is known about jamming for non-spherical particles, and particularly, non-convex particles. Here, we perform an experimental study on jamming by compression of a system of quasi-2D granular crosses made of photo-elastic crosses. We measure the pressure evolution during cyclic compression and decompression. The Jamming packing fraction of these quasi-2D granular crosses is ϕJ ≃ 0.475, which is much smaller than the value ϕJ ≃ 0.84 for-2D granular disks. The packing fraction shifts systematically to higher values under compressive cycling, corresponding to systematic shifts in the stress-strain response curves. Associated with these shifts are rotations of the crosses, with minimal changes in their centers of mass.

  5. [Ambulant compression therapy for crural ulcers; an effective treatment when applied skilfully].

    Science.gov (United States)

    de Boer, Edith M; Geerkens, Maud; Mooij, Michael C

    2015-01-01

    The incidence of crural ulcers is high. They reduce quality of life considerably and create a burden on the healthcare budget. The key treatment is ambulant compression therapy (ACT). We describe two patients with crural ulcers whose ambulant compression treatment was suboptimal and did not result in healing. When the bandages were applied correctly healing was achieved. If correctly applied ACT should provide sufficient pressure to eliminate oedema, whilst taking local circumstances such as bony structures and arterial qualities into consideration. To provide pressure-to-measure regular practical training, skills and regular quality checks are needed. Knowledge of the properties of bandages and the proper use of materials for padding under the bandage enables good personalised ACT. In trained hands adequate compression and making use of simple bandages and dressings provides good care for patients suffering from crural ulcers in contrast to inadequate ACT using the same materials.

  6. Analyzing the errors of DFT approximations for compressed water systems

    International Nuclear Information System (INIS)

    Alfè, D.; Bartók, A. P.; Csányi, G.; Gillan, M. J.

    2014-01-01

    We report an extensive study of the errors of density functional theory (DFT) approximations for compressed water systems. The approximations studied are based on the widely used PBE and BLYP exchange-correlation functionals, and we characterize their errors before and after correction for 1- and 2-body errors, the corrections being performed using the methods of Gaussian approximation potentials. The errors of the uncorrected and corrected approximations are investigated for two related types of water system: first, the compressed liquid at temperature 420 K and density 1.245 g/cm 3 where the experimental pressure is 15 kilobars; second, thermal samples of compressed water clusters from the trimer to the 27-mer. For the liquid, we report four first-principles molecular dynamics simulations, two generated with the uncorrected PBE and BLYP approximations and a further two with their 1- and 2-body corrected counterparts. The errors of the simulations are characterized by comparing with experimental data for the pressure, with neutron-diffraction data for the three radial distribution functions, and with quantum Monte Carlo (QMC) benchmarks for the energies of sets of configurations of the liquid in periodic boundary conditions. The DFT errors of the configuration samples of compressed water clusters are computed using QMC benchmarks. We find that the 2-body and beyond-2-body errors in the liquid are closely related to similar errors exhibited by the clusters. For both the liquid and the clusters, beyond-2-body errors of DFT make a substantial contribution to the overall errors, so that correction for 1- and 2-body errors does not suffice to give a satisfactory description. For BLYP, a recent representation of 3-body energies due to Medders, Babin, and Paesani [J. Chem. Theory Comput. 9, 1103 (2013)] gives a reasonably good way of correcting for beyond-2-body errors, after which the remaining errors are typically 0.5 mE h ≃ 15 meV/monomer for the liquid and the

  7. Experimental and Numerical Study of Jet Controlled Compression Ignition on Combustion Phasing Control in Diesel Premixed Compression Ignition Systems

    OpenAIRE

    Qiang Zhang; Wuqiang Long; Jiangping Tian; Yicong Wang; Xiangyu Meng

    2014-01-01

    In order to directly control the premixed combustion phasing, a Jet Controlled Compression Ignition (JCCI) for diesel premixed compression ignition systems is investigated. Experiments were conducted on a single cylinder natural aspirated diesel engine without EGR at 3000 rpm. Numerical models were validated by load sweep experiments at fixed spark timing. Detailed combustion characteristics were analyzed based on the BMEP of 2.18 bar. The simulation results showed that the high temperature j...

  8. A seismic data compression system using subband coding

    Science.gov (United States)

    Kiely, A. B.; Pollara, F.

    1995-01-01

    This article presents a study of seismic data compression techniques and a compression algorithm based on subband coding. The algorithm includes three stages: a decorrelation stage, a quantization stage that introduces a controlled amount of distortion to allow for high compression ratios, and a lossless entropy coding stage based on a simple but efficient arithmetic coding method. Subband coding methods are particularly suited to the decorrelation of nonstationary processes such as seismic events. Adaptivity to the nonstationary behavior of the waveform is achieved by dividing the data into separate blocks that are encoded separately with an adaptive arithmetic encoder. This is done with high efficiency due to the low overhead introduced by the arithmetic encoder in specifying its parameters. The technique could be used as a progressive transmission system, where successive refinements of the data can be requested by the user. This allows seismologists to first examine a coarse version of waveforms with minimal usage of the channel and then decide where refinements are required. Rate-distortion performance results are presented and comparisons are made with two block transform methods.

  9. Selected Issues on CO2 in Compression Systems

    Energy Technology Data Exchange (ETDEWEB)

    Aarlien, R.

    2004-05-15

    Carbon Dioxide (CO2) has shown promising results as an alternative working fluid compared to the CFCs, HFCs and HCFCs. CO2 provides an environmental friendly alternative in a number of heat pump applications, in automobile air conditioning, and as a secondary fluid in refrigeration systems. The physical and the thermodynamic properties of CO2 differ considerably from the more conventional working fluids and offer new possibilities as well as design challenges for systems and components. On this background IEA Heat Pump Programme's Annex 27 was established. The main objective of the Annex has been to bring the CO2 heat pump technology closer to commercialization, by addressing critical issues of both basic and applied character. The scope of the work under this Annex includes compression heat pump, refrigeration and air-conditioning systems and components, with the main emphasis on heat pumps, using CO2 as working fluid. The term 'compression heat pump' covers vapor compression circuits with phase change. The term 'system' includes all the components used in a heating/cooling system from the heat pump to the inside unit, controls included. Results from 12 different research projects together with an extensive literature survey are presented. The projects are carried out as independent research projects, and the findings and the results are the sole responsibility of the authors. The following projects are presented: 1) Feasibility of transcritical CO2 systems for mobile space conditioning applications. 2) Use of CO2- and propane thermosyphons in combination with compact cooler in domestic freeze. 3) Heat transfer of carbon dioxide in an evaporator. 4) Correlating the heat transfer coefficient during in-tube cooling of turbulent supercritical CO2. 5) Heat transfer and pressure drop characteristics of super-critical CO2 in microchannel tubes under cooling. 6) Flow vaporization of CO2 in microchannel tubes. 7) Two-phase flow patterns during

  10. A dynamic model of a photovoltaic vapour compression system

    International Nuclear Information System (INIS)

    Renno, C.

    2009-01-01

    A dynamic simulation of a photovoltaic vapour compression system is presented in this paper. In particular, there are several options to convert solar energy into refrigeration effect such as the absorption cycle, the thermo-mechanical refrigeration systems, the regenerative desiccant process or the steam jet system. This effect can also be produced by a conventional vapor compression cycle in which the compressor is driven by an electric motor supplied by means of photovoltaic cells. It is also possible to produce the cooling effect adopting the thermoelectric refrigeration, with electricity supplied by means of photovoltaic cells. Absorption and solar mechanical systems are necessarily larger and require extensive plumbing and electrical connections. The dynamic model allows to obtain some characteristic temperatures of the photovoltaic system and the energy consumptions with and without load perturbations. This model results a useful tool to study the dynamic working, for example, of photovoltaic refrigerators used in rural areas and remote islands, for their simple structure and low costs, to preserve foodstuffs, vaccines and other life saving medicines. (author)

  11. 49 CFR 571.303 - Standard No. 303; Fuel system integrity of compressed natural gas vehicles.

    Science.gov (United States)

    2010-10-01

    ... compressed natural gas vehicles. 571.303 Section 571.303 Transportation Other Regulations Relating to... system integrity of compressed natural gas vehicles. S1. Scope. This standard specifies requirements for the integrity of motor vehicle fuel systems using compressed natural gas (CNG), including the CNG fuel...

  12. JPEG2000 COMPRESSION CODING USING HUMAN VISUAL SYSTEM MODEL

    Institute of Scientific and Technical Information of China (English)

    Xiao Jiang; Wu Chengke

    2005-01-01

    In order to apply the Human Visual System (HVS) model to JPEG2000 standard,several implementation alternatives are discussed and a new scheme of visual optimization isintroduced with modifying the slope of rate-distortion. The novelty is that the method of visual weighting is not lifting the coefficients in wavelet domain, but is complemented by code stream organization. It remains all the features of Embedded Block Coding with Optimized Truncation (EBCOT) such as resolution progressive, good robust for error bit spread and compatibility of lossless compression. Well performed than other methods, it keeps the shortest standard codestream and decompression time and owns the ability of VIsual Progressive (VIP) coding.

  13. Researches on the CAES (Compressed Air Energy Storage) system

    Energy Technology Data Exchange (ETDEWEB)

    Shin Hee Soon; Kang, Sang Soo; Kwon, Kwang Soo [Korea Institute of Geology Mining and Materials, Taejon (Korea)] [and others

    1998-12-01

    CAES which is called as a compressed air energy storage was firstly developed at Huntorf, German in 1978. The capacity of that system was 290 MW, and it can be treated as a first commercial power plant. CAES has a lot of merits, such as saving the unit price of power generation, averaging the peak demand, improvement of maintenance, enlarging the benefit of dynamic use. According to the literature survey, the unlined rock cavern should be proposed to be a reasonable storing style as a method of compressed air storage in Korea. In this study, the most important techniques were evaluated through the investigation of the foreign construction case studies, especially on the unlined rock caverns in hard rock mass. We decided the hill of the Korea Institute of Geology, Mining and materials as CAES site. If we construct the underground spaces in this site, the demand for electricity nearby Taejon should be considered. So we could determine the capacity of the power plant as a 350 MW. This capacity needs a underground space of 200,000 m{sup 3}, and we can conclude 4 parallel tunnels through the numerical studies. Design parameters were achieved from 300 m depth boring job and image processing job. Moreover the techniques for determination of joint characteristics from the images could be obtained. Blasting pattern was designed on the underground spaces, and automatic gas control system and thermomechanical characteristics on caverns were also studied. (author). 51 refs., 79 tabs., 114 figs.

  14. New thermodynamical systems. Alternative of compression-absorption; Nouveaux systemes thermodynamiques. Alternative de la compression-absorption

    Energy Technology Data Exchange (ETDEWEB)

    Feidt, M.; Brunin, O.; Lottin, O.; Vidal, J.F. [Universite Henri Poincare Nancy, 54 - Vandoeuvre-les-Nancy (France); Hivet, B. [Electricite de France, 77 - Moret sur Loing (France)

    1996-12-31

    This paper describes a 5 years joint research work carried out by Electricite de France (EdF) and the ESPE group of the LEMTA on compression-absorption heat pumps. It shows how a thermodynamical model of machinery, completed with precise exchanger-reactor models, allows to simulate and dimension (and eventually optimize) the system. A small power prototype has been tested and the first results are analyzed with the help of the models. A real scale experiment in industrial sites is expected in the future. (J.S.) 20 refs.

  15. Improved fireman's compressed air breathing system pressure vessel development program

    Science.gov (United States)

    King, H. A.; Morris, E. E.

    1973-01-01

    Prototype high pressure glass filament-wound, aluminum-lined pressurant vessels suitable for use in a fireman's compressed air breathing system were designed, fabricated, and acceptance tested in order to demonstrate the feasibility of producing such high performance, lightweight units. The 4000 psi tanks have a 60 standard cubic foot (SCF) air capacity, and have a 6.5 inch diamter, 19 inch length, 415 inch volume, weigh 13 pounds when empty, and contain 33 percent more air than the current 45 SCF (2250 psi) steel units. The current steel 60 SCF (3000 psi) tanks weigh approximately twice as much as the prototype when empty, and are 2 inches, or 10 percent shorter. The prototype units also have non-rusting aluminum interiors, which removes the hazard of corrosion, the need for internal coatings, and the possibility of rust particles clogging the breathing system.

  16. Image acquisition system using on sensor compressed sampling technique

    Science.gov (United States)

    Gupta, Pravir Singh; Choi, Gwan Seong

    2018-01-01

    Advances in CMOS technology have made high-resolution image sensors possible. These image sensors pose significant challenges in terms of the amount of raw data generated, energy efficiency, and frame rate. This paper presents a design methodology for an imaging system and a simplified image sensor pixel design to be used in the system so that the compressed sensing (CS) technique can be implemented easily at the sensor level. This results in significant energy savings as it not only cuts the raw data rate but also reduces transistor count per pixel; decreases pixel size; increases fill factor; simplifies analog-to-digital converter, JPEG encoder, and JPEG decoder design; decreases wiring; and reduces the decoder size by half. Thus, CS has the potential to increase the resolution of image sensors for a given technology and die size while significantly decreasing the power consumption and design complexity. We show that it has potential to reduce power consumption by about 23% to 65%.

  17. The Basic Principles and Methods of the System Approach to Compression of Telemetry Data

    Science.gov (United States)

    Levenets, A. V.

    2018-01-01

    The task of data compressing of measurement data is still urgent for information-measurement systems. In paper the basic principles necessary for designing of highly effective systems of compression of telemetric information are offered. A basis of the offered principles is representation of a telemetric frame as whole information space where we can find of existing correlation. The methods of data transformation and compressing algorithms realizing the offered principles are described. The compression ratio for offered compression algorithm is about 1.8 times higher, than for a classic algorithm. Thus, results of a research of methods and algorithms showing their good perspectives.

  18. The Design of Compressed air system in the Conventional Facility of Proton Accelerator Research Center

    International Nuclear Information System (INIS)

    Jeon, G. P.; Kim, J. Y.; Cho, S. W.; Min, Y. S.; Mun, K. J.; Cho, J. S.; Nam, J. M.; Park, S. S.; Jo, J. H.

    2012-01-01

    The Compressed Air System (CA) supplies compressed air for all air operated devices and instruments, pneumatic equipment and other miscellaneous air user points in the Conventional Facilities of Proton Engineering Frontier Project. CA System consist of the Instrument Air System and the Service air System. The Instrument Air System supplies oil-free, dried, filtered, and compressed instrument air for the air operated control devices and instruments in the Accelerator and Beam Application Building, Ion Beam Application Building, Utility Building and etc.. The Service air System supplies compressed air for pneumatic equipment and other services

  19. Improving Compressed Air System Performance: A Sourcebook for Industry v3

    Energy Technology Data Exchange (ETDEWEB)

    Ron Marshall, William Scales, Gary Shafer, Paul Shaw, Paul Sheaffer, Rick Stasyshan, H.P.

    2016-03-01

    This sourcebook is designed to provide compressed air system users with a reference that outlines opportunities for system performance improvements. It is not intended to be a comprehensive technical text on improving compressed air systems, but rather a document that makes compressed air system users aware of the performance improvement potential, details some of the significant opportunities, and directs users to additional sources of assistance.

  20. Statistical Analysis of Compression Methods for Storing Binary Image for Low-Memory Systems

    Directory of Open Access Journals (Sweden)

    Roman Slaby

    2013-01-01

    Full Text Available The paper is focused on the statistical comparison of the selected compression methods which are used for compression of the binary images. The aim is to asses, which of presented compression method for low-memory system requires less number of bytes of memory. For assessment of the success rates of the input image to binary image the correlation functions are used. Correlation function is one of the methods of OCR algorithm used for the digitization of printed symbols. Using of compression methods is necessary for systems based on low-power micro-controllers. The data stream saving is very important for such systems with limited memory as well as the time required for decoding the compressed data. The success rate of the selected compression algorithms is evaluated using the basic characteristics of the exploratory analysis. The searched samples represent the amount of bytes needed to compress the test images, representing alphanumeric characters.

  1. Exploration of alginate hydrogel/nano zinc oxide composite bandages for infected wounds

    Directory of Open Access Journals (Sweden)

    Mohandas A

    2015-10-01

    Full Text Available Annapoorna Mohandas,* Sudheesh Kumar PT,* Biswas Raja, Vinoth-Kumar Lakshmanan, Rangasamy Jayakumar Amrita Centre for Nanosciences and Molecular Medicine, Amrita Institute of Medical Sciences and Research Centre, Amrita Vishwa Vidyapeetham University, Kochi, India *These authors contributed equally to this work Abstract: Alginate hydrogel/zinc oxide nanoparticles (nZnO composite bandage was developed by freeze-dry method from the mixture of nZnO and alginate hydrogel. The developed composite bandage was porous with porosity at a range of 60%–70%. The swelling ratios of the bandages decreased with increasing concentrations of nZnO. The composite bandages with nZnO incorporation showed controlled degradation profile and faster blood clotting ability when compared to the KALTOSTAT® and control bandages without nZnO. The prepared composite bandages exhibited excellent antimicrobial activity against Escherichia coli, Staphylococcus aureus, Candida albicans, and methicillin resistant S. aureus (MRSA. Cytocompatibility evaluation of the prepared composite bandages done on human dermal fibroblast cells by Alamar assay and infiltration studies proved that the bandages have a non-toxic nature at lower concentrations of nZnO whereas slight reduction in viability was seen with increasing nZnO concentrations. The qualitative analysis of ex-vivo re-epithelialization on porcine skin revealed keratinocyte infiltration toward wound area for nZnO alginate bandages. Keywords: alginate, hydrogel, ZnO nanoparticle, hemostatic, antimicrobial activity, wound healing

  2. Compressive System Identification in the Linear Time-Invariant framework

    KAUST Repository

    Toth, Roland

    2011-12-01

    Selection of an efficient model parametrization (model order, delay, etc.) has crucial importance in parametric system identification. It navigates a trade-off between representation capabilities of the model (structural bias) and effects of over-parametrization (variance increase of the estimates). There exists many approaches to this widely studied problem in terms of statistical regularization methods and information criteria. In this paper, an alternative ℓ 1 regularization scheme is proposed for estimation of sparse linear-regression models based on recent results in compressive sensing. It is shown that the proposed scheme provides consistent estimation of sparse models in terms of the so-called oracle property, it is computationally attractive for large-scale over-parameterized models and it is applicable in case of small data sets, i.e., underdetermined estimation problems. The performance of the approach w.r.t. other regularization schemes is demonstrated in an extensive Monte Carlo study. © 2011 IEEE.

  3. A Case Study of a Low Powervapour Compression Refrigeration System

    Science.gov (United States)

    Abinav, R.; Nambiar, G. K.; Sahu, Debjyoti

    2016-09-01

    Reported in this paper is a case study on a normal vapor compression refrigeration system which is expected to be run by photovoltaic panels to utilize minimum grid power. A small 120 W refrigerator is fabricated out of commercially available components and run by an inverter and battery connected to solar photovoltaic panel as well as grid. Temperature at several points was measured and the performance was evaluated. The Coefficient of performance (COP) to run such refrigerator is estimated after numerical simulation of major components namely, evaporator, condenser and a capillary tube. The simulation was done to obtain an effective cooling temperature and the results were compared with measured temperatures. Calculation proves to be in conformity with the actual model.

  4. Practical approach on gas pipeline compression system availability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Sidney Pereira dos [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Kurz, Rainer; Lubomirsky, Matvey [Solar Turbines, San Diego, CA (United States)

    2009-12-19

    Gas pipeline projects traditionally have been designed based on load factor and steady state flow. This approach exposes project sponsors to project sustainability risks due to potential losses of revenues and transportation contract penalties related to pipeline capacity shortage as consequence of compressor unit's unavailability. Such unavailability should previously be quantified during the design phase. This paper presents a case study and a methodology that highlights the practical benefits of applying Monte Carlo simulation for the compression system availability analysis in conjunction with quantitative risk analysis and economic feasibility study. Project economics main variables and their impacts on the project NPV (Net Present Value) are evaluated with their respective statistics distribution to quantify risk and support decision makers to adopt mitigating measures to guarantee competitiveness while protecting project sponsors from otherwise unpredictable risks. This practical approach is compared to load factor approach and the results are presented and evaluated. (author)

  5. Development of a Neutron Spectroscopic System Utilizing Compressed Sensing Measurements

    Directory of Open Access Journals (Sweden)

    Vargas Danilo

    2016-01-01

    Full Text Available A new approach to neutron detection capable of gathering spectroscopic information has been demonstrated. The approach relies on an asymmetrical arrangement of materials, geometry, and an ability to change the orientation of the detector with respect to the neutron field. Measurements are used to unfold the energy characteristics of the neutron field using a new theoretical framework of compressed sensing. Recent theoretical results show that the number of multiplexed samples can be lower than the full number of traditional samples while providing the ability to have some super-resolution. Furthermore, the solution approach does not require a priori information or inclusion of physics models. Utilizing the MCNP code, a number of candidate detector geometries and materials were modeled. Simulations were carried out for a number of neutron energies and distributions with preselected orientations for the detector. The resulting matrix (A consists of n rows associated with orientation and m columns associated with energy and distribution where n < m. The library of known responses is used for new measurements Y (n × 1 and the solver is able to determine the system, Y = Ax where x is a sparse vector. Therefore, energy spectrum measurements are a combination of the energy distribution information of the identified elements of A. This approach allows for determination of neutron spectroscopic information using a single detector system with analog multiplexing. The analog multiplexing allows the use of a compressed sensing solution similar to approaches used in other areas of imaging. A single detector assembly provides improved flexibility and is expected to reduce uncertainty associated with current neutron spectroscopy measurement.

  6. Compression therapy after ankle fracture surgery

    DEFF Research Database (Denmark)

    Winge, R; Bayer, L; Gottlieb, H

    2017-01-01

    PURPOSE: The main purpose of this systematic review was to investigate the effect of compression treatment on the perioperative course of ankle fractures and describe its effect on edema, pain, ankle joint mobility, wound healing complication, length of stay (LOS) and time to surgery (TTS). The aim...... undergoing surgery, testing either intermittent pneumatic compression, compression bandage and/or compression stocking and reporting its effect on edema, pain, ankle joint mobility, wound healing complication, LOS and TTS. To conclude on data a narrative synthesis was performed. RESULTS: The review included...

  7. Application of digital compression techniques to optical surveillance systems

    International Nuclear Information System (INIS)

    Johnson, C.S.

    1991-01-01

    There are many benefits to handling video images electronically, however, the amount of digital data in a normal video image is a major obstacle. The solution is to remove the high frequency and redundant information in a process that is referred to as compression. Compression allows the number of digital bits required for a given image to be reduced for more efficient storage or transmission of images. The next question is how much compression can be done without impairing the image quality beyond its usefulness for a given application. This paper discusses image compression that might be applied to provide useful images in unattended nuclear facility surveillance applications

  8. Relative stiffness of 3 bandage/splint constructs for stabilization of equine midmetacarpal fractures.

    Science.gov (United States)

    Lutter, John D; Cary, Julie A; Stephens, Robert R; Potts, Logan B

    2015-01-01

    Determine the relative stiffness of 3 bandage/splint constructs intended for emergency fracture stabilization. Experimental model. A single plane free end deflection model was developed to simulate the forces placed on a bandage/splint construct during stabilization of a complete mid-metacarpal bone fracture. The total deflection of the model in one plane was measured following application of 3 different bandage/splint combinations including a classic, 3 layered Robert Jones Bandage (RJB) with a splint placed on the outside of the bandage (RJB-3), an RJB with splint placed after the first of 3 bandage layers (RJB-1), and a single layer full limb bandage with external splint (SS). Comparisons were made between the deflections of the model with each bandage/splint combinations in an effort to determine the most effective method for field fracture stabilization. Laboratory. No animals were utilized in data collection for this study. Two live horses were utilized during the pilot study. Application of bandage and splint to a model intended to simulate the bending force on a lower forelimb fracture in a horse Deflection was determined by the difference between the height of the model's supported free end before application of a 4.5 kg weight and at the conclusion of the deflection test. There was no significant difference in the amount of deflection between bandage/splint combinations (78 ± 32 mm (RJB-1), 94 ± 44 mm (RJB-3), and 93 ± 33 mm (SS)) CONCLUSIONS: The one-layer bandage with splint was equivalent to either RJB configuration in the mean amount of deflection in the simple model of a fracture. © Veterinary Emergency and Critical Care Society 2015.

  9. Energy balance in a system with quasispherical linear compression

    International Nuclear Information System (INIS)

    Es'kov, A.G.; Kozlov, N.P.; Kurtmullaev, R.K.; Semenov, V.N.; Khvesyuk, V.I.; Yaminskii, A.V.

    1983-01-01

    This letter reports the resists of some experimental studies and a numerical simulation of the Tor-linear fusion system, 1 in which a heavy plasma shell with a closed magnetic structure is compressed in a quasispherical manner. The parameters of the Tor-Linear, at the Kurchatov Institute of Atomic Energy in Moscow are as follows: The energy stored in the system which accelerates the linear is E = 0.5 MJ; the linear mass is m = 0.2 kg; the working volume of the linear module is 1.5 x 10 -3 m 3 ; the linear velocity is approx.10 3 m/s; the guiding field in the toriod in the linear is 1--10 x 10 21 m -3 ; and the intial volume of the plasma in the linear chamber is 2.5 x 10 -4 m 3 . In this series of experiments, new solutions were developed for all the systems of the plasma--linear complex of the Tor-Linear: to produce a plasma toroid, to transport it, and to trap it in the linear cavity

  10. Effect of evaporator temperature on vapor compression refrigeration system

    Directory of Open Access Journals (Sweden)

    Abdullah A.A.A. Al-Rashed

    2011-12-01

    Full Text Available This paper presents a comparable evaluation of R600a (isobutane, R290 (propane, R134a, R22, for R410A, and R32 an optimized finned-tube evaporator, and analyzes the evaporator effect on the system coefficient of performance (COP. Results concerning the response of a refrigeration system simulation software to an increase in the amount of oil flowing with the refrigerant are presented. It is shown that there is optima of the apparent overheat value, for which either the exchanged heat or the refrigeration coefficient of performance (COP is maximized: consequently, it is not possible to optimize both the refrigeration COP and the evaporator effect. The obtained evaporator optimization results were incorporated in a conventional analysis of the vapor compression system. For a theoretical cycle analysis without accounting for evaporator effects, the COP spread for the studied refrigerants was as high as 11.7%. For cycle simulations including evaporator effects, the COP of R290 was better than that of R22 by up to 3.5%, while the remaining refrigerants performed approximately within a 2% COP band of the R22 baseline for the two condensing temperatures considered.

  11. Efficiency increase in ship's primal energy system using a multistage compression with intercooling

    Directory of Open Access Journals (Sweden)

    Landeka Petar

    2016-01-01

    Full Text Available This paper focuses on an analysis of the potential increase of efficiency in ship's primal energy system using a turbocharger with multistage compression with intercooling, and diverting a greater flow of exhaust gases to power turbine of waste heat recovery system (WHR. Analysis of potential efficiency increase has been made for various stages of compression for a 100 % main engine load, and an analysis of five stage compression with intercooling for a main engine load between 50% and 100%.

  12. Performance of a hydraulic air compressor for use in compressed air energy storage power systems

    Energy Technology Data Exchange (ETDEWEB)

    Berghmans, J. A.; Ahrens, F. W.

    1978-01-01

    A fluid mechanical analysis of a hydraulic air compression system for Compressed Air Energy Storage (CAES) application is presented. With this compression concept, air is charged into an underground reservoir, for later use in power generation, by entraining bubbles into a downward flow of water from a surface reservoir. Upon releasing the air in the underground reservoir, the water is pumped back to the surface. The analytical model delineated is used to predict the hydraulic compressor performance characteristics (pumping power, pump head, compression efficiency) as a function of water flow rate and system geometrical parameters. The results indicate that, although large water pumps are needed, efficiencies as high as 90% (relative to ideal isothermal compression) can be expected. This should result in lower compression power than for conventional compressor systems, while eliminating the need for the usual intercoolers and aftercooler.

  13. Pressure mapping with textile sensors for compression therapy monitoring.

    Science.gov (United States)

    Baldoli, Ilaria; Mazzocchi, Tommaso; Paoletti, Clara; Ricotti, Leonardo; Salvo, Pietro; Dini, Valentina; Laschi, Cecilia; Francesco, Fabio Di; Menciassi, Arianna

    2016-08-01

    Compression therapy is the cornerstone of treatment in the case of venous leg ulcers. The therapy outcome is strictly dependent on the pressure distribution produced by bandages along the lower limb length. To date, pressure monitoring has been carried out using sensors that present considerable drawbacks, such as single point instead of distributed sensing, no shape conformability, bulkiness and constraints on patient's movements. In this work, matrix textile sensing technologies were explored in terms of their ability to measure the sub-bandage pressure with a suitable temporal and spatial resolution. A multilayered textile matrix based on a piezoresistive sensing principle was developed, calibrated and tested with human subjects, with the aim of assessing real-time distributed pressure sensing at the skin/bandage interface. Experimental tests were carried out on three healthy volunteers, using two different bandage types, from among those most commonly used. Such tests allowed the trends of pressure distribution to be evaluated over time, both at rest and during daily life activities. Results revealed that the proposed device enables the dynamic assessment of compression mapping, with a suitable spatial and temporal resolution (20 mm and 10 Hz, respectively). In addition, the sensor is flexible and conformable, thus well accepted by the patient. Overall, this study demonstrates the adequacy of the proposed piezoresistive textile sensor for the real-time monitoring of bandage-based therapeutic treatments. © IMechE 2016.

  14. Assessment of market potential of compressed air energy storage systems

    Science.gov (United States)

    Boyd, D. W.; Buckley, O. E.; Clark, C. E., Jr.

    1983-12-01

    This report describes an assessment of potential roles that EPRI might take to facilitate the commercial acceptance of compressed air energy storage (CAES) systems. The assessment is based on (1) detailed analyses of the market potential of utility storage technologies, (2) interviews with representatives of key participants in the CAES market, and (3) a decision analysis synthesizing much of the information about market and technology status. The results indicate a large potential market for CAES systems if the overall business environment for utilities improves. In addition, it appears that EPRI can have a valuable incremental impact in ensuring that utilities realize the potential of CAES by (1) continuing an aggressive information dissemination and technology transfer program, (2) working to ensure the success of the first United States CAES installation at Soyland Power Cooperative, (3) developing planning methods to allow utilities to evaluate CAES and other storage options more effectively and more realistically, and (4) supporting R and D to resolve residual uncertainties in first-generation CAES cost and performance characteristics. Previously announced in STAR as N83-25121

  15. SLIB77, Source Library Data Compression and File Maintenance System

    International Nuclear Information System (INIS)

    Lunsford, A.

    1989-01-01

    Description of program or function: SLIB77 is a source librarian program designed to maintain FORTRAN source code in a compressed form on magnetic disk. The program was prepared to meet program maintenance requirements for ongoing program development and continual improvement of very large programs involving many programmers from a number of different organizations. SLIB77 automatically maintains in one file the source of the current program as well as all previous modifications. Although written originally for FORTRAN programs, SLIB77 is suitable for use with data files, text files, operating systems, and other programming languages, such as Ada, C and COBOL. It can handle libraries with records of up to 160-characters. Records are grouped into DECKS and assigned deck names by the user. SLIB77 assigns a number to each record in each DECK. Records can be deleted or restored singly or as a group within each deck. Modification records are grouped and assigned modification identification names by the user. The program assigns numbers to each new record within the deck. The program has two modes of execution, BATCH and EDIT. The BATCH mode is controlled by an input file and is used to make changes permanent and create new library files. The EDIT mode is controlled by interactive terminal input and a built-in line editor is used for modification of single decks. Transferring of a library from one computer system to another is accomplished using a Portable Library File created by SLIB77 in a BATCH run

  16. Operability Test Report for 241-U Compressed Air System and heat pump

    International Nuclear Information System (INIS)

    Rensink, G.E.

    1995-01-01

    The 241-U-701 compressed air system supplies instrument quality compressed air to Tank Farm 241-U. The system was upgraded. The operability test showed that the system operates within its intended design parameters. System performance was monitored, recorded, and used to identify areas of concern. Exceptions to the OTP and additional items for safe system performance were minimal and have been resolved; the air system is ready for Operation's use

  17. Structural analysis of compression helical spring used in suspension system

    Science.gov (United States)

    Jain, Akshat; Misra, Sheelam; Jindal, Arun; Lakhian, Prateek

    2017-07-01

    The main aim of this work has to develop a helical spring for shock absorber used in suspension system which is designed to reduce shock impulse and liberate kinetic energy. In a vehicle, it increases comfort by decreasing amplitude of disturbances and it improves ride quality by absorbing and dissipating energy. When a vehicle is in motion on a road and strikes a bump, spring comes into action quickly. After compression, spring will attempt to come to its equilibrium state which is on level road. Helical springs can be made lighter with more strength by reducing number of coils and increasing the area. In this research work, a helical spring is modeled and analyzed to substitute the existing steel spring which is used in suspension. By using different materials, stress and deflection of helical spring can be varied. Comparability between existing spring and newly replaced spring is used to verify the results. For finding detailed stress distribution, finite element analysis is used to find stresses and deflection in both the helical springs. Finite element analysis is a method which is used to find proximate solutions of a physical problem defined in a finite domain. In this research work, modeling of spring is accomplished using Solid Works and analysis on Ansys.

  18. Experimental and Numerical Study of Jet Controlled Compression Ignition on Combustion Phasing Control in Diesel Premixed Compression Ignition Systems

    Directory of Open Access Journals (Sweden)

    Qiang Zhang

    2014-07-01

    Full Text Available In order to directly control the premixed combustion phasing, a Jet Controlled Compression Ignition (JCCI for diesel premixed compression ignition systems is investigated. Experiments were conducted on a single cylinder natural aspirated diesel engine without EGR at 3000 rpm. Numerical models were validated by load sweep experiments at fixed spark timing. Detailed combustion characteristics were analyzed based on the BMEP of 2.18 bar. The simulation results showed that the high temperature jets of reacting active radical species issued from the ignition chamber played an important role on the onset of combustion in the JCCI system. The combustion of diesel pre-mixtures was initiated rapidly by the combustion products issued from the ignition chamber. Moreover, the flame propagation was not obvious, similar to that in Pre-mixed Charge Compression Ignition (PCCI. Consequently, spark timing sweep experiments were conducted. The results showed a good linear relationship between spark timing in the ignition chamber and CA10 and CA50, which indicated the ability for direct combustion phasing control in diesel PCCI. The NOx and soot emissions gradually changed with the decrease of spark advance angle. The maximum reduction of NOx and soot were both over 90%, and HC and CO emissions were increased.

  19. Space communication system for compressed data with a concatenated Reed-Solomon-Viterbi coding channel

    Science.gov (United States)

    Rice, R. F.; Hilbert, E. E. (Inventor)

    1976-01-01

    A space communication system incorporating a concatenated Reed Solomon Viterbi coding channel is discussed for transmitting compressed and uncompressed data from a spacecraft to a data processing center on Earth. Imaging (and other) data are first compressed into source blocks which are then coded by a Reed Solomon coder and interleaver, followed by a convolutional encoder. The received data is first decoded by a Viterbi decoder, followed by a Reed Solomon decoder and deinterleaver. The output of the latter is then decompressed, based on the compression criteria used in compressing the data in the spacecraft. The decompressed data is processed to reconstruct an approximation of the original data-producing condition or images.

  20. Compression therapy in mixed ulcers increases venous output and arterial perfusion.

    Science.gov (United States)

    Mosti, Giovanni; Iabichella, Maria Letizia; Partsch, Hugo

    2012-01-01

    This study was conducted to define bandage pressures that are safe and effective in treating leg ulcers of mixed arterial-venous etiology. In 25 patients with mixed-etiology leg ulcers who received inelastic bandages applied with pressures from 20 to 30, 31 to 40, and 41 to 50 mm Hg, the following measurements were performed before and after bandage application to ensure patient safety throughout the investigation: laser Doppler fluxmetry (LDF) close to the ulcer under the bandage and at the great toe, transcutaneous oxygen pressure (TcPo(2)) on the dorsum of the foot, and toe pressure. Ejection fraction (EF) of the venous pump was performed to assess efficacy on venous hemodynamics. LDF values under the bandages increased by 33% (95% confidence interval [CI], 17-48; P pressure ranges applied. At toe level, a significant decrease in flux of -20% (95% CI, -48 to 9; P bandage pressure >41 mm Hg. Toe pressure values and TcPo(2) showed a moderate increase, excluding a restriction to arterial perfusion induced by the bandages. Inelastic bandages were highly efficient in improving venous pumping function, increasing the reduced ejection fraction by 72% (95% CI, 50%-95%; P pressure of 21 to 30 mm Hg and by 103% (95% CI, 70%-128%; P ulceration, an ankle-brachial pressure index >0.5 and an absolute ankle pressure of >60 mm Hg, inelastic compression of up to 40 mm Hg does not impede arterial perfusion but may lead to a normalization of the highly reduced venous pumping function. Such bandages are therefore recommended in combination with walking exercises as the basic conservative management for patients with mixed leg ulcers. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  1. The Use of the D-STAT Dry Bandage for the Control of Vascular Access Site Bleeding: A Multicenter Experience in 376 Patients

    International Nuclear Information System (INIS)

    Hallak, Omar K.; Cubeddu, Roberto J.; Griffith, Rose A.; Reyes, Bernardo J.

    2007-01-01

    Multiple topical hemostats have been approved for control of surface bleeding from vascular access sites. The majority of these devices, however, have few clinical data supporting their use. This study was conducted to assess the efficacy and safety of the new commercially available D-Stat Dry hemostatic bandage compared to standard care manual compression. A prospective, randomized, multicenter trial was conducted in patients undergoing diagnostic cardiac catheterization or peripheral angiography utilizing femoral artery access. Subjects were randomized to either the D-Stat Dry bandage as an adjunct to manual compression or manual compression alone. Primary end points were time-to-hemostasis (TTH) and major complications. Secondary end points included minor complications, patient satisfaction, time-to-ambulation (TTA), and time-to-discharge (TTD). Three hundred seventy-six subjects (189 control, 187 investigational) with similar baseline characteristics participated in the study. The mean age was 61.5 years, with a male predominance of 58%. TTH was significantly lower in the investigational group (7.8 vs. 13.0 min; p = 0.001). No difference in major complication rates was observed between the groups. The mean TTA (investigational, 392 min, vs. control, 415 min; p = 0.023) and patient satisfaction significantly favored the investigational group (p = 0.025). No difference in TTD or the rate of minor complications was observed. This study demonstrates that in the aforementioned population, the D-Stat Dry bandage is safe and effective in reducing both TTH and TTA and results in improved patient satisfaction

  2. Operability Test Report for 241-T compressed air system and heat pump

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1995-02-01

    This Operability Test Report (OTR) documents the results of functional testing performed on the operating parameters of the 241-T-701 Compressed Air System. The System was successfully installed and tested per work package 2W-92-01172

  3. How control system design affects performance evaluation compression: The role of information accuracy and bonus transparency

    NARCIS (Netherlands)

    Bol, J. C.; Kramer, S.; Maas, V.S.

    2016-01-01

    Prior research has shown that managers tend to compress ratings when subjectively evaluating employees and that such compression can have negative organizational consequences. We reason that organizations can use the design of their control system to influence the personal costs and benefits

  4. Lempel–Ziv Data Compression on Parallel and Distributed Systems

    Directory of Open Access Journals (Sweden)

    Sergio De Agostino

    2011-09-01

    Full Text Available We present a survey of results concerning Lempel–Ziv data compression on parallel and distributed systems, starting from the theoretical approach to parallel time complexity to conclude with the practical goal of designing distributed algorithms with low communication cost. Storer’s extension for image compression is also discussed.

  5. Preparation of silver-chitosan nanocomposites and coating on bandage for antibacterial wound dressing application

    Energy Technology Data Exchange (ETDEWEB)

    Susilowati, Endang, E-mail: endwati@yahoo.co.id; Ashadi [Chemistry Education Department, Faculty of Teacher Training and Education, Universitas Sebelas Maret Surakarta (Indonesia); Maryani [Medical Doctor Program, Faculty of Medicine, Universitas Sebelas Maret Surakarta, Indonesia Jl. Ir Sutami 36 A Surakarta Indonesia 53126 (Indonesia)

    2016-02-08

    Bandage is a medical device that is essential for wound dressing. To improve the performance of the bandage, it has been coated by silver-chitosan nanocomposites (Ag/Chit) with pad-dry-cure method. The nanocomposites were performed by chemical reduction method at room temperature using glucose as reducing agent, sodium hydroxide (NaOH) as accelerator reagent, silver nitrate (AgNO{sub 3}) as metal precursor and chitosan as stabilizing agent. Localized surface plasmon resonance (LSPR) absorption band of silver nanoparticles was investigated using UV-Vis spectrophotometer. The bandage coated Ag/Chit nanocomposites (B-Ag/Chit) were characterized by fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and scanning electron microscope (SEM). In addition, antibacterial activity of the bandage toward Gram positive (Staphylococcus aureus) and Gram negative (Escherichia coli) were also studied. The formation of silver nanoparticles was confirmed by the appearance of LSPR absorption peak at 412.2 – 423.2 nm. Coating of nanocomposite cause increasing rigidity of bandage and decreasing on crystallinity. The bandages of B-Ag/Chit demonstrated good activity against both Gram positive (S. aureus) and Gram negative (E.Coli). Thus the bandages have a potential to be used for antibacterial wound dressing application.

  6. Image compression-encryption algorithms by combining hyper-chaotic system with discrete fractional random transform

    Science.gov (United States)

    Gong, Lihua; Deng, Chengzhi; Pan, Shumin; Zhou, Nanrun

    2018-07-01

    Based on hyper-chaotic system and discrete fractional random transform, an image compression-encryption algorithm is designed. The original image is first transformed into a spectrum by the discrete cosine transform and the resulting spectrum is compressed according to the method of spectrum cutting. The random matrix of the discrete fractional random transform is controlled by a chaotic sequence originated from the high dimensional hyper-chaotic system. Then the compressed spectrum is encrypted by the discrete fractional random transform. The order of DFrRT and the parameters of the hyper-chaotic system are the main keys of this image compression and encryption algorithm. The proposed algorithm can compress and encrypt image signal, especially can encrypt multiple images once. To achieve the compression of multiple images, the images are transformed into spectra by the discrete cosine transform, and then the spectra are incised and spliced into a composite spectrum by Zigzag scanning. Simulation results demonstrate that the proposed image compression and encryption algorithm is of high security and good compression performance.

  7. A Coded Aperture Compressive Imaging Array and Its Visual Detection and Tracking Algorithms for Surveillance Systems

    Directory of Open Access Journals (Sweden)

    Hanxiao Wu

    2012-10-01

    Full Text Available In this paper, we propose an application of a compressive imaging system to the problem of wide-area video surveillance systems. A parallel coded aperture compressive imaging system is proposed to reduce the needed high resolution coded mask requirements and facilitate the storage of the projection matrix. Random Gaussian, Toeplitz and binary phase coded masks are utilized to obtain the compressive sensing images. The corresponding motion targets detection and tracking algorithms directly using the compressive sampling images are developed. A mixture of Gaussian distribution is applied in the compressive image space to model the background image and for foreground detection. For each motion target in the compressive sampling domain, a compressive feature dictionary spanned by target templates and noises templates is sparsely represented. An l1 optimization algorithm is used to solve the sparse coefficient of templates. Experimental results demonstrate that low dimensional compressed imaging representation is sufficient to determine spatial motion targets. Compared with the random Gaussian and Toeplitz phase mask, motion detection algorithms using a random binary phase mask can yield better detection results. However using random Gaussian and Toeplitz phase mask can achieve high resolution reconstructed image. Our tracking algorithm can achieve a real time speed that is up to 10 times faster than that of the l1 tracker without any optimization.

  8. A parallelizable compression scheme for Monte Carlo scatter system matrices in PET image reconstruction

    International Nuclear Information System (INIS)

    Rehfeld, Niklas; Alber, Markus

    2007-01-01

    Scatter correction techniques in iterative positron emission tomography (PET) reconstruction increasingly utilize Monte Carlo (MC) simulations which are very well suited to model scatter in the inhomogeneous patient. Due to memory constraints the results of these simulations are not stored in the system matrix, but added or subtracted as a constant term or recalculated in the projector at each iteration. This implies that scatter is not considered in the back-projector. The presented scheme provides a method to store the simulated Monte Carlo scatter in a compressed scatter system matrix. The compression is based on parametrization and B-spline approximation and allows the formation of the scatter matrix based on low statistics simulations. The compression as well as the retrieval of the matrix elements are parallelizable. It is shown that the proposed compression scheme provides sufficient compression so that the storage in memory of a scatter system matrix for a 3D scanner is feasible. Scatter matrices of two different 2D scanner geometries were compressed and used for reconstruction as a proof of concept. Compression ratios of 0.1% could be achieved and scatter induced artifacts in the images were successfully reduced by using the compressed matrices in the reconstruction algorithm

  9. GPU Lossless Hyperspectral Data Compression System for Space Applications

    Science.gov (United States)

    Keymeulen, Didier; Aranki, Nazeeh; Hopson, Ben; Kiely, Aaron; Klimesh, Matthew; Benkrid, Khaled

    2012-01-01

    On-board lossless hyperspectral data compression reduces data volume in order to meet NASA and DoD limited downlink capabilities. At JPL, a novel, adaptive and predictive technique for lossless compression of hyperspectral data, named the Fast Lossless (FL) algorithm, was recently developed. This technique uses an adaptive filtering method and achieves state-of-the-art performance in both compression effectiveness and low complexity. Because of its outstanding performance and suitability for real-time onboard hardware implementation, the FL compressor is being formalized as the emerging CCSDS Standard for Lossless Multispectral & Hyperspectral image compression. The FL compressor is well-suited for parallel hardware implementation. A GPU hardware implementation was developed for FL targeting the current state-of-the-art GPUs from NVIDIA(Trademark). The GPU implementation on a NVIDIA(Trademark) GeForce(Trademark) GTX 580 achieves a throughput performance of 583.08 Mbits/sec (44.85 MSamples/sec) and an acceleration of at least 6 times a software implementation running on a 3.47 GHz single core Intel(Trademark) Xeon(Trademark) processor. This paper describes the design and implementation of the FL algorithm on the GPU. The massively parallel implementation will provide in the future a fast and practical real-time solution for airborne and space applications.

  10. Does comprilan bandage have any influence on peripheral perfusion in patients with oedema?

    DEFF Research Database (Denmark)

    Midttun, M; Ahmadzay, N F; Henriksen, J H

    2010-01-01

    Comprilan bandage may be an attractive treatment of leg oedema, but theoretically bandage could compromise peripheral circulation. The present study was undertaken to investigate circulation in the first toe before, during, and after treatment with comprilan bandage. METHODS AND STUDY POPULATION......: Blood flow rate was measured by the heat-washout method in the pulp of the first toe of 10 patients (eight women, two men, aged 75-94) with leg oedemas, and systolic toe blood pressure was determined by the strain gauge method. Oedema was scored according to a visual scale, and the patients were treated...

  11. Design of bunch compressing system with suppression of coherent synchrotron radiation for ATF upgrade

    International Nuclear Information System (INIS)

    Jing, Yichao; Fedurin, Mikhail; Stratakis, Diktys

    2015-01-01

    One of the operation modes for Accelerator Test Facility (ATF) upgrade is to provide high peak current, high quality electron beam for users. Such operation requires a bunch compressing system with a very large compression ratio. The CSR originating from the strong compressors generally could greatly degrade the quality of the electron beam. In this paper, we present our design for the entire bunch compressing system that will limit the effect of CSR on the e-beam@s quality. We discuss and detail the performance from the start to end simulation of such a compressor for ATF.

  12. The compression algorithm for the data acquisition system in HT-7 tokamak

    International Nuclear Information System (INIS)

    Zhu Lin; Luo Jiarong; Li Guiming; Yue Dongli

    2003-01-01

    HT-7 superconducting tokamak in the Institute of Plasma Physics of the Chinese Academy of Sciences is an experimental device for fusion research in China. The main task of the data acquisition system of HT-7 is to acquire, store, analyze and index the data. The volume of the data is nearly up to hundreds of million bytes. Besides the hardware and software support, a great capacity of data storage, process and transfer is a more important problem. To deal with this problem, the key technology is data compression algorithm. In the paper, the data format in HT-7 is introduced first, then the data compression algorithm, LZO, being a kind of portable lossless data compression algorithm with ANSIC, is analyzed. This compression algorithm, which fits well with the data acquisition and distribution in the nuclear fusion experiment, offers a pretty fast compression and extremely fast decompression. At last the performance evaluation of LZO application in HT-7 is given

  13. Experience with compressed air system of Dhruva and Cirus

    International Nuclear Information System (INIS)

    Shelar, V.G.; Patil, U.D.; Singh, V.K.; Zope, A.K.; Kharpate, A.V.

    2006-01-01

    Dhruva and Cirus reactors have independent compressed air plants with provision for sharing. Dhruva has the reciprocating oil free air compressors where as Cirus has oil lubricated compressors. Over the years, several improvements have been done in the equipments to combat various problems, among these noise mitigation in Dhruva and measures to extend life of compressors in Cirus and also incidence of discharge header catching fire are interesting. This paper details these experiences. (author)

  14. Drift compression and final focus systems for heavy ion inertial fusion

    Energy Technology Data Exchange (ETDEWEB)

    de Hoon, Michiel Jan Laurens [Univ. of California, Berkeley, CA (United States)

    2001-01-01

    Longitudinal compression of space-charge dominated beams can be achieved by imposing a head-to-tail velocity tilt on the beam. This tilt has to be carefully tailored, such that it is removed by the longitudinal space-charge repulsion by the time the beam reaches the end of the drift compression section. The transverse focusing lattice should be designed such that all parts of the beam stay approximately matched, while the beam smoothly expands transversely to the larger beam radius needed in the final focus system following drift compression. In this thesis, several drift compression systems were designed within these constraints, based on a given desired pulse shape at the end of drift compression systems were designed within these constraints, based on a given desired pulse shape at the end of drift compression. The occurrence of mismatches due to a rapidly increasing current was analyzed. In addition, the sensitivity of drift compression to errors in the initial velocity tilt and current profile was studied. These calculations were done using a new computer code that accurately calculates the longitudinal electric field in the space-charge dominated regime.

  15. Energy Efficiency Analysis of Discharge Modes of an Adiabatic Compressed Air Energy Storage System

    OpenAIRE

    Shane D. Inder; Mehrdad Khamooshi

    2017-01-01

    Efficient energy storage is a crucial factor in facilitating the uptake of renewable energy resources. Among the many options available for energy storage systems required to balance imbalanced supply and demand cycles, compressed air energy storage (CAES) is a proven technology in grid-scale applications. This paper reviews the current state of micro scale CAES technology and describes a micro-scale advanced adiabatic CAES (A-CAES) system, where heat generated during compression is stored fo...

  16. Operability test procedure for 241-U compressed air system and heat pump

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1994-01-01

    The 241-U-701 compressed air system supplies instrument quality compressed air to Tank Farm 241-U. The supply piping to the 241-U Tank Farm is not included in the modification. Modifications to the 241-U-701 compressed air system include installation of a 15 HP Reciprocating Air Compressor, Ingersoll-Rand Model 10T3NLM-E15; an air dryer, Hankinson, Model DH-45; and miscellaneous system equipment and piping (valves, filters, etc.) to meet the design. A newly installed heat pump allows the compressor to operate within an enclosed relatively dust free atmosphere and keeps the compressor room within a standard acceptable temperature range, which makes possible efficient compressor operation, reduces maintenance, and maximizes compressor operating life. This document is an Operability Test Procedure (OTP) which will further verify (in addition to the Acceptance Test Procedure) that the 241-U-701 compressed air system and heat pump operate within their intended design parameters. The activities defined in this OTP will be performed to ensure the performance of the new compressed air system will be adequate, reliable and efficient. Completion of this OTP and sign off of the OTP Acceptance of Test Results is necessary for turnover of the compressed air system from Engineering to Operations

  17. In vitro results of flexible light-emitting antimicrobial bandage designed for prevention of surgical site infections

    Science.gov (United States)

    Greenberg, Mitchell; Sharan, Riti; Galbadage, Thushara; Sule, Preeti; Smith, Robert; Lovelady, April; Cirillo, Jeffrey D.; Glowczwski, Alan; Maitland, Kristen C.

    2018-02-01

    Surgical site infections (SSIs) are a leading cause of morbidity and mortality and a significant expense to the healthcare system and hospitals. The majority of these infections are preventable; however, increasing bacterial resistance, biofilm persistence, and human error contribute to the occurrence of these healthcare-associated infections. We present a flexible antimicrobial blue-light emitting bandage designed for use on postoperative incisions and wounds. The photonic device is designed to inactivate bacteria present on the skin and prevent bacterial colonization of the site, thus reducing the occurrence of SSIs. This antimicrobial light emitting bandage uses blue light's proven abilities to inactivate a wide range of clinical pathogens regardless of their resistance to antibiotics, inactivate bacteria without harming mammalian cells, improve wound healing, and inactivate bacteria in biofilms. The antimicrobial bandage consists of a thin 2"x2" silicone sheet with an array of 77 LEDs embedded in multiple layers of the material for thermal management. The 405 nm center wavelength LED array is designed to be a wearable device that integrates with standard hospital infection prevention protocols. The device was characterized for irradiance of 44.5 mW/cm2. Methicillin-resistant Staphylococcus aureus seeded in a petri dish was used to evaluate bacterial inactivation in vitro. Starting with a concentration of 2.16 x 107 colony forming units (CFU)/mL, 45% of the bacteria was inactivated within 15 minutes, 65% had been inactivated by 30 minutes, 99% was inactivated by 60 minutes, and a 7 log reduction and complete sterilization was achieved within 120 minutes.

  18. SU-E-J-190: Development of Abdominal Compression & Respiratory Guiding System Using Gas Pressure Sensor

    International Nuclear Information System (INIS)

    Kim, T; Kim, D; Kang, S; Cho, M; Kim, K; Shin, D; Suh, T; Kim, S

    2015-01-01

    Purpose: Abdominal compression is known to be effective but, often makes external-marker-based monitoring of breathing motion not feasible. In this study, we developed and evaluated a system that enables both abdominal compression and monitoring of residual abdominal motion simultaneously. The system can also provide visual-biofeedback capability. Methods: The system developed consists of a compression belt, an abdominal motion monitoring sensor (gas pressure sensor) and a visual biofeedback device. The compression belt was designed to be able to compress the frontal side of the abdomen. The pressure level of the belt is controlled by air volume and monitored in real time using the gas pressure sensor. The system displays not only the real-time monitoring curve but also a guiding respiration model (e.g., a breath hold or shallow breathing curve) simultaneously on the head mounted display to help patients keep their breathing pattern as consistent as possible. Three healthy volunteers were enrolled in this pilot study and respiratory signals (pressure variations) were obtained both with and without effective abdominal compression to investigate the feasibility of the developed system. Two guidance patterns, breath hold and shallow breathing, were tested. Results: All volunteers showed smaller abdominal motion with compression (about 40% amplitude reduction compared to without compression). However, the system was able to monitor residual abdominal motion for all volunteers. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed abdominal compression & respiratory guiding system was feasible for residual abdominal motion management. It is considered that the system can be used for a respiratory motion involved radiation therapy while maintaining the merit of abdominal compression. This work was supported by the Radiation Technology R

  19. SU-E-J-190: Development of Abdominal Compression & Respiratory Guiding System Using Gas Pressure Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T; Kim, D; Kang, S; Cho, M; Kim, K; Shin, D; Suh, T [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Kim, S [Virginia Commonwealth University, Richmond, VA (United States)

    2015-06-15

    Purpose: Abdominal compression is known to be effective but, often makes external-marker-based monitoring of breathing motion not feasible. In this study, we developed and evaluated a system that enables both abdominal compression and monitoring of residual abdominal motion simultaneously. The system can also provide visual-biofeedback capability. Methods: The system developed consists of a compression belt, an abdominal motion monitoring sensor (gas pressure sensor) and a visual biofeedback device. The compression belt was designed to be able to compress the frontal side of the abdomen. The pressure level of the belt is controlled by air volume and monitored in real time using the gas pressure sensor. The system displays not only the real-time monitoring curve but also a guiding respiration model (e.g., a breath hold or shallow breathing curve) simultaneously on the head mounted display to help patients keep their breathing pattern as consistent as possible. Three healthy volunteers were enrolled in this pilot study and respiratory signals (pressure variations) were obtained both with and without effective abdominal compression to investigate the feasibility of the developed system. Two guidance patterns, breath hold and shallow breathing, were tested. Results: All volunteers showed smaller abdominal motion with compression (about 40% amplitude reduction compared to without compression). However, the system was able to monitor residual abdominal motion for all volunteers. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed abdominal compression & respiratory guiding system was feasible for residual abdominal motion management. It is considered that the system can be used for a respiratory motion involved radiation therapy while maintaining the merit of abdominal compression. This work was supported by the Radiation Technology R

  20. Structural transitions and hysteresis in clump- and stripe-forming systems under dynamic compression

    International Nuclear Information System (INIS)

    McDermott, Danielle; Reichhardt, Charles

    2016-01-01

    In using numerical simulations, we study the dynamical evolution of particles interacting via competing long-range repulsion and short-range attraction in two dimensions. The particles are compressed using a time-dependent quasi-one dimensional trough potential that controls the local density, causing the system to undergo a series of structural phase transitions from a low density clump lattice to stripes, voids, and a high density uniform state. The compression proceeds via slow elastic motion that is interrupted with avalanche-like bursts of activity as the system collapses to progressively higher densities via plastic rearrangements. The plastic events vary in magnitude from small rearrangements of particles, including the formation of quadrupole-like defects, to large-scale vorticity and structural phase transitions. In the dense uniform phase, the system compresses through row reduction transitions mediated by a disorder-order process. We also characterize the rearrangement events by measuring changes in the potential energy, the fraction of sixfold coordinated particles, the local density, and the velocity distribution. At high confinements, we find power law scaling of the velocity distribution during row reduction transitions. We observe hysteresis under a reversal of the compression when relatively few plastic rearrangements occur. The decompressing system exhibits distinct phase morphologies, and the phase transitions occur at lower compression forces as the system expands compared to when it is compressed.

  1. Numerical study on the lubrication performance of compression ring-cylinder liner system with spherical dimples.

    Directory of Open Access Journals (Sweden)

    Cheng Liu

    Full Text Available The effects of surface texture on the lubrication performance of a compression ring-cylinder liner system are studied in this paper. By considering the surface roughness of the compression ring and cylinder liner, a mixed lubrication model is presented to investigate the tribological behaviors of a barrel-shaped compression ring-cylinder liner system with spherical dimples on the liner. In order to determine the rupture and reformulation positions of fluid film accurately, the Jacoboson-Floberg-Olsson (JFO cavitation boundary condition is applied to the mixed lubrication model for ensuring the mass-conservative law. On this basis, the minimum oil film thickness and average friction forces in the compression ring-cylinder liner system are investigated under the engine-like conditions by changing the dimple area density, radius, and depth. The wear load, average friction forces, and power loss of the compression ring-cylinder liner system with and without dimples are also compared for different compression ring face profiles. The results show that the spherical dimples can produce a larger reduction of friction in mixed lubrication region, and reduce power loss significantly in the middle of the strokes. In addition, higher reduction percentages of average friction forces and wear are obtained for smaller crown height or larger axial width.

  2. Focal-plane change triggered video compression for low-power vision sensor systems.

    Directory of Open Access Journals (Sweden)

    Yu M Chi

    Full Text Available Video sensors with embedded compression offer significant energy savings in transmission but incur energy losses in the complexity of the encoder. Energy efficient video compression architectures for CMOS image sensors with focal-plane change detection are presented and analyzed. The compression architectures use pixel-level computational circuits to minimize energy usage by selectively processing only pixels which generate significant temporal intensity changes. Using the temporal intensity change detection to gate the operation of a differential DCT based encoder achieves nearly identical image quality to traditional systems (4dB decrease in PSNR while reducing the amount of data that is processed by 67% and reducing overall power consumption reduction of 51%. These typical energy savings, resulting from the sparsity of motion activity in the visual scene, demonstrate the utility of focal-plane change triggered compression to surveillance vision systems.

  3. Freeing Space for NASA: Incorporating a Lossless Compression Algorithm into NASA's FOSS System

    Science.gov (United States)

    Fiechtner, Kaitlyn; Parker, Allen

    2011-01-01

    NASA's Fiber Optic Strain Sensing (FOSS) system can gather and store up to 1,536,000 bytes (1.46 megabytes) per second. Since the FOSS system typically acquires hours - or even days - of data, the system can gather hundreds of gigabytes of data for a given test event. To store such large quantities of data more effectively, NASA is modifying a Lempel-Ziv-Oberhumer (LZO) lossless data compression program to compress data as it is being acquired in real time. After proving that the algorithm is capable of compressing the data from the FOSS system, the LZO program will be modified and incorporated into the FOSS system. Implementing an LZO compression algorithm will instantly free up memory space without compromising any data obtained. With the availability of memory space, the FOSS system can be used more efficiently on test specimens, such as Unmanned Aerial Vehicles (UAVs) that can be in flight for days. By integrating the compression algorithm, the FOSS system can continue gathering data, even on longer flights.

  4. SU-F-T-91: Development of Real Time Abdominal Compression Force (ACF) Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T; Kim, D; Kang, S; Cho, M; Kim, K; Shin, D; Noh, Y; Suh, T [Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, S [Virginia Commonwealth University, Richmond, VA (United States)

    2016-06-15

    Purpose: Hard-plate based abdominal compression is known to be effective, but no explicit method exists to quantify abdominal compression force (ACF) and maintain the proper ACF through the whole procedure. In addition, even with compression, it is necessary to do 4D CT to manage residual motion but, 4D CT is often not possible due to reduced surrogating sensitivity. In this study, we developed and evaluated a system that both monitors ACF in real time and provides surrogating signal even under compression. The system can also provide visual-biofeedback. Methods: The system developed consists of a compression plate, an ACF monitoring unit and a visual-biofeedback device. The ACF monitoring unit contains a thin air balloon in the size of compression plate and a gas pressure sensor. The unit is attached to the bottom of the plate thus, placed between the plate and the patient when compression is applied, and detects compression pressure. For reliability test, 3 volunteers were directed to take several different breathing patterns and the ACF variation was compared with the respiratory flow and external respiratory signal to assure that the system provides corresponding behavior. In addition, guiding waveform were generated based on free breathing, and then applied for evaluating the effectiveness of visual-biofeedback. Results: We could monitor ACF variation in real time and confirmed that the data was correlated with both respiratory flow data and external respiratory signal. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed real time ACF monitoring system was found to be functional as intended and consistent. With the capability of both providing real time surrogating signal under compression and enabling visual-biofeedback, it is considered that the system would improve the quality of respiratory motion management in radiation

  5. SU-F-T-91: Development of Real Time Abdominal Compression Force (ACF) Monitoring System

    International Nuclear Information System (INIS)

    Kim, T; Kim, D; Kang, S; Cho, M; Kim, K; Shin, D; Noh, Y; Suh, T; Kim, S

    2016-01-01

    Purpose: Hard-plate based abdominal compression is known to be effective, but no explicit method exists to quantify abdominal compression force (ACF) and maintain the proper ACF through the whole procedure. In addition, even with compression, it is necessary to do 4D CT to manage residual motion but, 4D CT is often not possible due to reduced surrogating sensitivity. In this study, we developed and evaluated a system that both monitors ACF in real time and provides surrogating signal even under compression. The system can also provide visual-biofeedback. Methods: The system developed consists of a compression plate, an ACF monitoring unit and a visual-biofeedback device. The ACF monitoring unit contains a thin air balloon in the size of compression plate and a gas pressure sensor. The unit is attached to the bottom of the plate thus, placed between the plate and the patient when compression is applied, and detects compression pressure. For reliability test, 3 volunteers were directed to take several different breathing patterns and the ACF variation was compared with the respiratory flow and external respiratory signal to assure that the system provides corresponding behavior. In addition, guiding waveform were generated based on free breathing, and then applied for evaluating the effectiveness of visual-biofeedback. Results: We could monitor ACF variation in real time and confirmed that the data was correlated with both respiratory flow data and external respiratory signal. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed real time ACF monitoring system was found to be functional as intended and consistent. With the capability of both providing real time surrogating signal under compression and enabling visual-biofeedback, it is considered that the system would improve the quality of respiratory motion management in radiation

  6. Exergy and exergoeconomic analysis of a Compressed Air Energy Storage combined with a district energy system

    International Nuclear Information System (INIS)

    Bagdanavicius, Audrius; Jenkins, Nick

    2014-01-01

    Highlights: • CAES and CAES with thermal storage systems were investigated. • The potential for using heat generated during the compression stage was analysed. • CAES-TS has the potential to be used both as energy storage and heat source. • CAES-TS could be a useful tool for balancing overall energy demand and supply. - Abstract: The potential for using heat generated during the compression stage of a Compressed Air Energy Storage system was investigated using exergy and exergoeconomic analysis. Two Compressed Air Energy Storage systems were analysed: Compressed Air Energy Storage (CAES) and Compressed Air Energy Storage combined with Thermal Storage (CAES-TS) connected to a district heating network. The maximum output of the CAES was 100 MWe and the output of the CAES-TS was 100 MWe and 105 MWth. The study shows that 308 GW h/year of electricity and 466 GW h/year of fuel are used to generate 375 GW h/year of electricity. During the compression of air 289 GW h/year of heat is generated, which is wasted in the CAES and used for district heating in the CAES-TS system. Energy efficiency of the CAES system was around 48% and the efficiency of CAES-TS was 86%. Exergoeconomic analysis shows that the exergy cost of electricity generated in the CAES was 13.89 ¢/kW h, and the exergy cost of electricity generated in the CAES-TS was 11.20 ¢/kW h. The exergy cost of heat was 22.24 ¢/kW h in the CAES-TS system. The study shows that CAES-TS has the potential to be used both as energy storage and heat source and could be a useful tool for balancing overall energy demand and supply

  7. Development of real time abdominal compression force monitoring and visual biofeedback system

    Science.gov (United States)

    Kim, Tae-Ho; Kim, Siyong; Kim, Dong-Su; Kang, Seong-Hee; Cho, Min-Seok; Kim, Kyeong-Hyeon; Shin, Dong-Seok; Suh, Tae-Suk

    2018-03-01

    In this study, we developed and evaluated a system that could monitor abdominal compression force (ACF) in real time and provide a surrogating signal, even under abdominal compression. The system could also provide visual-biofeedback (VBF). The real-time ACF monitoring system developed consists of an abdominal compression device, an ACF monitoring unit and a control system including an in-house ACF management program. We anticipated that ACF variation information caused by respiratory abdominal motion could be used as a respiratory surrogate signal. Four volunteers participated in this test to obtain correlation coefficients between ACF variation and tidal volumes. A simulation study with another group of six volunteers was performed to evaluate the feasibility of the proposed system. In the simulation, we investigated the reproducibility of the compression setup and proposed a further enhanced shallow breathing (ESB) technique using VBF by intentionally reducing the amplitude of the breathing range under abdominal compression. The correlation coefficient between the ACF variation caused by the respiratory abdominal motion and the tidal volume signal for each volunteer was evaluated and R 2 values ranged from 0.79 to 0.84. The ACF variation was similar to a respiratory pattern and slight variations of ACF ranges were observed among sessions. About 73-77% average ACF control rate (i.e. compliance) over five trials was observed in all volunteer subjects except one (64%) when there was no VBF. The targeted ACF range was intentionally reduced to achieve ESB for VBF simulation. With VBF, in spite of the reduced target range, overall ACF control rate improved by about 20% in all volunteers except one (4%), demonstrating the effectiveness of VBF. The developed monitoring system could help reduce the inter-fraction ACF set up error and the intra fraction ACF variation. With the capability of providing a real time surrogating signal and VBF under compression, it could

  8. Analysis of Compression Algorithm in Ground Collision Avoidance Systems (Auto-GCAS)

    Science.gov (United States)

    Schmalz, Tyler; Ryan, Jack

    2011-01-01

    Automatic Ground Collision Avoidance Systems (Auto-GCAS) utilizes Digital Terrain Elevation Data (DTED) stored onboard a plane to determine potential recovery maneuvers. Because of the current limitations of computer hardware on military airplanes such as the F-22 and F-35, the DTED must be compressed through a lossy technique called binary-tree tip-tilt. The purpose of this study is to determine the accuracy of the compressed data with respect to the original DTED. This study is mainly interested in the magnitude of the error between the two as well as the overall distribution of the errors throughout the DTED. By understanding how the errors of the compression technique are affected by various factors (topography, density of sampling points, sub-sampling techniques, etc.), modifications can be made to the compression technique resulting in better accuracy. This, in turn, would minimize unnecessary activation of A-GCAS during flight as well as maximizing its contribution to fighter safety.

  9. Elastic Bandaging for Orthopedic- and Sports-Injury Prevention and Rehabilitation: A Systematic Review.

    Science.gov (United States)

    Fousekis, Konstantinos; Billis, Evdokia; Matzaroglou, Charalampos; Mylonas, Konstantinos; Koutsojannis, Constantinos; Tsepis, Elias

    2017-05-01

    Elastic bandages are commonly used in sports to treat and prevent sport injuries. To conduct a systematic review assessing the effectiveness of elastic bandaging in orthopedic- and sports-injury prevention and rehabilitation. The researchers searched the electronic databases MEDLINE, CINAHL, SPORTDiscus, EMBASE, and Physiotherapy Evidence Database (PEDro) with keywords elastic bandaging in combination, respectively, with first aid, sports injuries, orthopedic injuries, and sports injuries prevention and rehabilitation. Research studies were selected based on the use of the term elastic bandaging in the abstract. Final selection was made by applying inclusion and exclusion criteria to the full text. Studies were included if they were peer-reviewed clinical trials written in English on the effects of elastic bandaging for orthopedic-injury prevention and rehabilitation. Twelve studies met the criteria and were included in the final analysis. Data collected included number of participants, condition being treated, treatment used, control group, outcome measures, and results. Studies were critically analyzed using the PEDro scale. The studies in this review fell into 2 categories: studies in athletes (n = 2) and nonathletes (n = 10). All included trials had moderate to high quality, scoring ≥5 on the PEDro scale. The PEDro scores for the studies in athletes and nonathletes ranged from 5 to 6 out of 10 and from 5 to 8 out of 10, respectively. The quality of studies was mixed, ranging from higher- to moderate-quality methodological clinical trials. Overall, elastic bandaging can assist proprioceptive function of knee and ankle joint. Because of the moderate methodological quality and insufficient number of clinical trials, further effects of elastic bandaging could not be confirmed.

  10. Low cryogen inventory, forced flow Ne cooling system with room temperature compression stage and heat recuperation

    CERN Document Server

    Shornikov, A; Wolf, A

    2014-01-01

    We present design and commissioning results of a forced flow cooling system utilizing neon at 30 K. The cryogen is pumped through the system by a room-temperature compression stage. To decouple the cold zone from the compression stage a recuperating counterflow tube-in-tube heat exchanger is used. Commissioning demonstrated successful condensation of neon and transfer of up to 30 W cooling power to the load at 30 K using only 30 g of the cryogen circulating in the system at pressures below 170 kPa.

  11. A high-speed lossless data compression system for space applications

    Science.gov (United States)

    Miko, Joe; Fong, Wai; Miller, Warner

    1993-01-01

    This paper reports on the integration of a lossless data compression/decompression chipset into a space data system architecture. For its compression engine, the data system incorporates the Universal Source Encoder (USE) designed for the NASA/Goddard Space Flight Center. Currently, the data compression testbed generates video frames consisting of 512 lines of 512 pixels having 8-bit resolution. Each image is passed through the USE where the lines are internally partitioned into 16-word blocks. These blocks are adaptively encoded across widely varying entropy levels using a Rice 12-option set coding algorithm. The current system operates at an Input/Output rate of 10 Msamples/s or 80 Mbits/s for each buffered input line. Frame and line synchronization for each image are maintained through the use of uniquely decodable command words. Length information of each variable length compressed image line is also included in the output stream. The data and command information are passed to the next stage of the system architecture through a serial fiber-optic transmitter. The initial segment of this stage consists of packetizer hardware which adds an appropriate CCSDS header to the received source data. An uncompressed mode is optionally available to pass image lines directly to the packetizer hardware. A data decompression testbed has also been developed to confirm the data compression operation.

  12. Thermal analysis of near-isothermal compressed gas energy storage system

    International Nuclear Information System (INIS)

    Odukomaiya, Adewale; Abu-Heiba, Ahmad; Gluesenkamp, Kyle R.; Abdelaziz, Omar; Jackson, Roderick K.; Daniel, Claus; Graham, Samuel; Momen, Ayyoub M.

    2016-01-01

    Highlights: • A novel, high-efficiency, scalable, near-isothermal, energy storage system is introduced. • A comprehensive analytical physics-based model for the system is presented. • Efficiency improvement is achieved via heat transfer enhancement and use of waste heat. • Energy storage roundtrip efficiency (RTE) of 82% and energy density of 3.59 MJ/m"3 is shown. - Abstract: Due to the increasing generation capacity of intermittent renewable electricity sources and an electrical grid ill-equipped to handle the mismatch between electricity generation and use, the need for advanced energy storage technologies will continue to grow. Currently, pumped-storage hydroelectricity and compressed air energy storage are used for grid-scale energy storage, and batteries are used at smaller scales. However, prospects for expansion of these technologies suffer from geographic limitations (pumped-storage hydroelectricity and compressed air energy storage), low roundtrip efficiency (compressed air energy storage), and high cost (batteries). Furthermore, pumped-storage hydroelectricity and compressed air energy storage are challenging to scale-down, while batteries are challenging to scale-up. In 2015, a novel compressed gas energy storage prototype system was developed at Oak Ridge National Laboratory. In this paper, a near-isothermal modification to the system is proposed. In common with compressed air energy storage, the novel storage technology described in this paper is based on air compression/expansion. However, several novel features lead to near-isothermal processes, higher efficiency, greater system scalability, and the ability to site a system anywhere. The enabling features are utilization of hydraulic machines for expansion/compression, above-ground pressure vessels as the storage medium, spray cooling/heating, and waste-heat utilization. The base configuration of the novel storage system was introduced in a previous paper. This paper describes the results

  13. [Comparison of efficacy of heel ulcer prevention between classic padded bandage and polyurethane heel in a medium-stay hospital: randomized controlled trial].

    Science.gov (United States)

    Ferrer Solà, Marta; Espaulella Panicot, Joan; Altimires Roset, Jacint; Ylla-Català Borè, Elisenda; Moreno Susi, María

    2013-01-01

    The aim of the study is to determine the incidence of heel pressure ulcers (UPPT) and to compare the two systems for UPPT prevention: classic padded bandage and polyurethane heel. Prospective intervention study in a medium-long hospital stay of all people admitted that had no UPPT but had a risk of UPPT according to the Braden Scale or clinical judgment. The patients were randomized to prevention with classic padded bandage or polyurethane heel. The outcome variable was the incidence of UPPT for each study group, which was recorded every 15 days or when there were clinical changes. Of the 940 patients evaluated, 409 with a mean age of 80.5 years and 59.1% women,were included in the study. Of these, 78% had Barthel score ≤30; 28.6% dementia; delirium 37.6%; 27.6% diabetes; and 19.6% other UPP. The overall incidence was 2.9% UPPT; 2.49% in the classic padded bandage and 3.37% in the polyurethane heel group (p=0.82). No statistically significant differences were observed between the group with the classical dressing and the group with the polyurethane heel dressing. The use of multiple measures to prevent UPPT achieved a low incidence of these. Copyright © 2011 SEGG. Published by Elsevier Espana. All rights reserved.

  14. Isobaric expansion coefficient and isothermal compressibility for a finite-size ideal Fermi gas system

    International Nuclear Information System (INIS)

    Su, Guozhen; Chen, Liwei; Chen, Jincan

    2014-01-01

    Due to quantum size effects (QSEs), the isobaric thermal expansion coefficient and isothermal compressibility well defined for macroscopic systems are invalid for finite-size systems. The two parameters are redefined and calculated for a finite-size ideal Fermi gas confined in a rectangular container. It is found that the isobaric thermal expansion coefficient and isothermal compressibility are generally anisotropic, i.e., they are generally different in different directions. Moreover, it is found the thermal expansion coefficient may be negative in some directions under the condition that the pressures in all directions are kept constant. - Highlights: • Isobaric thermal expansion coefficient and isothermal compressibility are redefined. • The two parameters are calculated for a finite-size ideal Fermi gas. • The two parameters are generally anisotropic for a finite-size system. • Isobaric thermal expansion coefficient may be negative in some directions

  15. Evaluation of turbine systems for compressed air energy storage plants. Final report for FY 1976

    Energy Technology Data Exchange (ETDEWEB)

    Kartsounes, G.T.

    1976-10-01

    Compressed air energy storage plants for electric utility peak-shaving applications comprise four subsystems: a turbine system, compressor system, an underground air storage reservoir, and a motor/generator. Proposed plant designs use turbines that are derived from available gas and steam turbines with proven reliability. The study examines proposed turbine systems and presents an evaluation of possible systems that may reduce capital cost and/or improve performance. Six new turbine systems are identified for further economic evaluation.

  16. Parallel compression of data chunks of a shared data object using a log-structured file system

    Science.gov (United States)

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2016-10-25

    Techniques are provided for parallel compression of data chunks being written to a shared object. A client executing on a compute node or a burst buffer node in a parallel computing system stores a data chunk generated by the parallel computing system to a shared data object on a storage node by compressing the data chunk; and providing the data compressed data chunk to the storage node that stores the shared object. The client and storage node may employ Log-Structured File techniques. The compressed data chunk can be de-compressed by the client when the data chunk is read. A storage node stores a data chunk as part of a shared object by receiving a compressed version of the data chunk from a compute node; and storing the compressed version of the data chunk to the shared data object on the storage node.

  17. Bi-layered nanocomposite bandages for controlling microbial infections and overproduction of matrix metalloproteinase activity.

    Science.gov (United States)

    Anjana, J; Mohandas, Annapoorna; Seethalakshmy, S; Suresh, Maneesha K; Menon, Riju; Biswas, Raja; Jayakumar, R

    2018-04-15

    Chronic diabetic wounds is characterised by increased microbial contamination and overproduction of matrix metalloproteases that would degrade the extracellular matrix. A bi-layer bandage was developed, that promotes the inhibition of microbial infections and matrix metalloprotease (MMPs) activity. Bi-layer bandage containing benzalkonium chloride loaded gelatin nanoparticles (BZK GNPs) in chitosan-Hyaluronic acid (HA) as a bottom layer and sodium alendronate containing chitosan as top layer was developed. We hypothesized that the chitosan-gelatin top layer with sodium alendronate could inhibit the MMPs activity, whereas the chitosan-HA bottom layer with BZK GNPs (240±66nm) would enable the elimination of microbes. The porosity, swelling and degradation nature of the prepared Bi-layered bandage was studied. The bottom layer could degrade within 4days whereas the top layer remained upto 7days. The antimicrobial activity of the BZK NPs loaded bandage was determined using normal and clinical strains. Gelatin zymography shows that the proteolytic activity of MMP was inhibited by the bandage. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Retrofit device and method to improve humidity control of vapor compression cooling systems

    Science.gov (United States)

    Roth, Robert Paul; Hahn, David C.; Scaringe, Robert P.

    2016-08-16

    A method and device for improving moisture removal capacity of a vapor compression system is disclosed. The vapor compression system is started up with the evaporator blower initially set to a high speed. A relative humidity in a return air stream is measured with the evaporator blower operating at the high speed. If the measured humidity is above the predetermined high relative humidity value, the evaporator blower speed is reduced from the initially set high speed to the lowest possible speed. The device is a control board connected with the blower and uses a predetermined change in measured relative humidity to control the blower motor speed.

  19. Compressed-air and backup nitrogen systems in nuclear power plants

    International Nuclear Information System (INIS)

    Hagen, E.W.

    1982-07-01

    This report reviews and evaluates the performance of the compressed-air and pressurized-nitrogen gas systems in commercial nuclear power units. The information was collected from readily available operating experiences, licensee event reports, system designs in safety analysis reports, and regulatory documents. The results are collated and analyzed for significance and impact on power plant safety performance. Under certain circumstances, the fail-safe philosophy for a piece of equipment or subsystem of the compressed-air systems initiated a series of actions culminating in reactor transient or unit scram. However, based on this study of prevailing operating experiences, reclassifying the compressed-gas systems to a higher safety level will neither prevent (nor mitigate) the reoccurrences of such happenings nor alleviate nuclear power plant problems caused by inadequate maintenance, operating procedures, and/or practices. Conversely, because most of the problems were derived from the sources listed previously, upgrading of both maintenance and operating procedures will not only result in substantial improvement in the performance and availability of the compressed-air (and backup nitrogen) systems but in improved overall plant performance

  20. Performance of vapor compression systems with compressor oil flooding and regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Bell, Ian H.; Groll, Eckhard A.; Braun, James E. [Purdue University, Department of Mechanical Engineering, 140 S. Martin Jischke Drive, West Lafayette, IN 47906 (United States)

    2011-01-15

    Vapor compression refrigeration technology has seen great improvement over the last several decades in terms of cycle efficiency through a concerted effort of manufacturers, regulators, and research engineers. As the standard vapor compression systems approach practical limits, cycle modifications should be investigated to increase system efficiency and capacity. One possible means of increasing cycle efficiency is to flood the compressor with a large quantity of oil to achieve a quasi-isothermal compression process, in addition to using a regenerator to increase refrigerant subcooling. In theory, compressor flooding and regeneration can provide a significant increase in system efficiency over the standard vapor compression system. The effectiveness of compressor flooding and regeneration increases as the temperature lift of the system increases. Therefore, this technology is particularly well suited towards lower evaporating temperatures and high ambient temperatures as seen in supermarket refrigeration applications. While predicted increases in cycle efficiency are over 40% for supermarket refrigeration applications, this technology is still very beneficial for typical air-conditioning applications, for which improvements in cycle efficiency greater than 5% are predicted. It has to be noted though that the beneficial effects of compressor flooding can only be realized if a regenerator is used to exchange heat between the refrigerant vapor exiting the evaporator and the liquid exiting the condenser. (author)

  1. Preparation of the egg membrane bandage contained the antibacterial Ag nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jin; Duan, Guangwen [Department of Materials and Chemical Engineering, Hainan University, 570228 Haikou (China); Fu, Yunzhi, E-mail: yzhfu@hainu.edu.cn [Department of Materials and Chemical Engineering, Hainan University, 570228 Haikou (China); Zhao, Jinsheng [Shandong Key Laboratory of Chemical Energy-Storage and Novel Cell Technology, Liaocheng University, 252059 Liaocheng (China)

    2015-02-15

    Silver nanoparticles were synthesized using a rapid, single step, and completely green biosynthetic method employing aqueous aloe leaf extracts as both the reducing and capping agent. Transmission electron microscopy analysis revealed the average size of silver nanoparticles approximately 18.05 nm. Fourier transform infrared spectroscopy observation showed the estimation of two kinds of binding sites between aqueous aloe leaf and aqueous aloe leaf with silver nanoparticles. In addition, the critical roles of the concentration of silver nitrate, temperature, and reaction time in the formation of silver nanoparticles had been illustrated. Furthermore, silver nanoparticles were deposited on egg membrane bandage, forming a new egg membrane bandage that contained silver nanoparticles that exhibiting excellent antibacterial effects against Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus, which was 2.5 times stronger than the commercially available bandage. - Graphical Abstract: Display Omitted.

  2. Air ejector augmented compressed air energy storage system

    Science.gov (United States)

    Ahrens, F.W.; Kartsounes, G.T.

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air presure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  3. The impact of decongestive physical therapy and elastic bandaging on the control of pain in patients with venous ulcers

    Directory of Open Access Journals (Sweden)

    GERALDO MAGELA SALOMÉ

    2018-03-01

    Full Text Available ABSTRACT Objective: to evaluate pain in individuals with venous ulcers treated with elastic bandage and decongestant physical therapy. Methods: we studied 90 patients, divided into three groups with 30 patients each: a group treated with elastic bandage and decongestant physical therapy; a group treated with elastic bandage; and a group treated only with primary dressing according to tissue type and presence of exudate. We used the Pain Numerical Scale to quantify pain intensity and the McGill Pain Questionnaire for pain qualitative assessment. Results: in the first evaluation, all patients who participated in the study reported intense pain. In the fifth evaluation, the majority of patients treated with elastic bandaging and decongestant physical therapy did not report pain; the majority of patients in the elastic bandage group reported mild pain; and most patients treated only with primary dressing reported mild to moderate pain. During all five assessments using the McGill questionnaire, most patients in the elastic bandaging and primary dressing groups used descriptors of the sensory, affective, evaluative and miscellaneous groups to describe their pain. However, in the fourth and fifth evaluations, most patients who received decongestant physical therapy combined with elastic bandaging treatment did not use any of the descriptors. Conclusion: patients treated with decongestant physical therapy and elastic bandage presented pain improvement from the third evaluation performed on.

  4. System and method for compressive scanning electron microscopy

    Science.gov (United States)

    Reed, Bryan W

    2015-01-13

    A scanning transmission electron microscopy (STEM) system is disclosed. The system may make use of an electron beam scanning system configured to generate a plurality of electron beam scans over substantially an entire sample, with each scan varying in electron-illumination intensity over a course of the scan. A signal acquisition system may be used for obtaining at least one of an image, a diffraction pattern, or a spectrum from the scans, the image, diffraction pattern, or spectrum representing only information from at least one of a select subplurality or linear combination of all pixel locations comprising the image. A dataset may be produced from the information. A subsystem may be used for mathematically analyzing the dataset to predict actual information that would have been produced by each pixel location of the image.

  5. Compressive System Identification in the Linear Time-Invariant framework

    KAUST Repository

    Toth, Roland; Sanandaji, Borhan M.; Poolla, Kameshwar; Vincent, Tyrone L.

    2011-01-01

    Selection of an efficient model parametrization (model order, delay, etc.) has crucial importance in parametric system identification. It navigates a trade-off between representation capabilities of the model (structural bias) and effects of over-parametrization

  6. Hybrid compression of video with graphics in DTV communication systems

    OpenAIRE

    Schaar, van der, M.; With, de, P.H.N.

    2000-01-01

    Advanced broadcast manipulation of TV sequences and enhanced user interfaces for TV systems have resulted in an increased amount of pre- and post-editing of video sequences, where graphical information is inserted. However, in the current broadcasting chain, there are no provisions for enabling an efficient transmission/storage of these mixed video and graphics signals and, at this emerging stage of DTV systems, introducing new standards is not desired. Nevertheless, in the professional video...

  7. Initial results for compressive sensing in electronic support receiver systems

    CSIR Research Space (South Africa)

    Du Plessis, WP

    2011-04-01

    Full Text Available determined by the antenna and microwave system comprising the transmitter and receiver, while the instantaneous bandwidth is mainly determined by the Analog-to-Digital Converter (ADC) in the receiver. A radar can thus operate at any frequency within its... Electronic/Electromagnetic Support Measures (ESM) was used historically [1], [2]. Modern ES receiver systems are based on digital receivers allowing powerful signal processing techniques to be used [3], [4]. Recent developments in sampling technology...

  8. Inertia and compressibility effects on density waves and Ledinegg phenomena in two-phase flow systems

    International Nuclear Information System (INIS)

    Ruspini, L.C.

    2012-01-01

    Highlights: ► The stability influence of piping fluid inertia on two-phase instabilities is studied. ► Inlet inertia stabilizes the system while outlet inertia destabilizes it. ► High-order modes oscillations are found and analyzed. ► The effect of compressible volumes in the system is studied. ► Inlet compressibility destabilizes the system while outlet comp. stabilizes it. - Abstract: The most common kind of static and dynamic two-phase flow instabilities namely Ledinegg and density wave oscillations are studied. A new model to study two-phase flow instabilities taking into account general parameters from real systems is proposed. The stability influence of external parameters such as the fluid inertia and the presence of compressible gases in the system is analyzed. High-order oscillation modes are found to be related with the fluid inertia of external piping. The occurrence of high-order modes in experimental works is analyzed with focus on the results presented in this work. Moreover, both inertia and compressibility are proven to have a high impact on the stability limits of the systems. The performed study is done by modeling the boiling channel using a one dimensional equilibrium model. An incompressible transient model describes the evolution of the flow and pressure in the non-heated regions and an ideal gas model is used to simulate the compressible volumes in the system. The use of wavelet decomposition analysis is proven to be an efficient tool in stability analysis of several frequencies oscillations.

  9. Influence of video compression on the measurement error of the television system

    Science.gov (United States)

    Sotnik, A. V.; Yarishev, S. N.; Korotaev, V. V.

    2015-05-01

    Video data require a very large memory capacity. Optimal ratio quality / volume video encoding method is one of the most actual problem due to the urgent need to transfer large amounts of video over various networks. The technology of digital TV signal compression reduces the amount of data used for video stream representation. Video compression allows effective reduce the stream required for transmission and storage. It is important to take into account the uncertainties caused by compression of the video signal in the case of television measuring systems using. There are a lot digital compression methods. The aim of proposed work is research of video compression influence on the measurement error in television systems. Measurement error of the object parameter is the main characteristic of television measuring systems. Accuracy characterizes the difference between the measured value abd the actual parameter value. Errors caused by the optical system can be selected as a source of error in the television systems measurements. Method of the received video signal processing is also a source of error. Presence of error leads to large distortions in case of compression with constant data stream rate. Presence of errors increases the amount of data required to transmit or record an image frame in case of constant quality. The purpose of the intra-coding is reducing of the spatial redundancy within a frame (or field) of television image. This redundancy caused by the strong correlation between the elements of the image. It is possible to convert an array of image samples into a matrix of coefficients that are not correlated with each other, if one can find corresponding orthogonal transformation. It is possible to apply entropy coding to these uncorrelated coefficients and achieve a reduction in the digital stream. One can select such transformation that most of the matrix coefficients will be almost zero for typical images . Excluding these zero coefficients also

  10. Wavelet-based Encoding Scheme for Controlling Size of Compressed ECG Segments in Telecardiology Systems.

    Science.gov (United States)

    Al-Busaidi, Asiya M; Khriji, Lazhar; Touati, Farid; Rasid, Mohd Fadlee; Mnaouer, Adel Ben

    2017-09-12

    One of the major issues in time-critical medical applications using wireless technology is the size of the payload packet, which is generally designed to be very small to improve the transmission process. Using small packets to transmit continuous ECG data is still costly. Thus, data compression is commonly used to reduce the huge amount of ECG data transmitted through telecardiology devices. In this paper, a new ECG compression scheme is introduced to ensure that the compressed ECG segments fit into the available limited payload packets, while maintaining a fixed CR to preserve the diagnostic information. The scheme automatically divides the ECG block into segments, while maintaining other compression parameters fixed. This scheme adopts discrete wavelet transform (DWT) method to decompose the ECG data, bit-field preserving (BFP) method to preserve the quality of the DWT coefficients, and a modified running-length encoding (RLE) scheme to encode the coefficients. The proposed dynamic compression scheme showed promising results with a percentage packet reduction (PR) of about 85.39% at low percentage root-mean square difference (PRD) values, less than 1%. ECG records from MIT-BIH Arrhythmia Database were used to test the proposed method. The simulation results showed promising performance that satisfies the needs of portable telecardiology systems, like the limited payload size and low power consumption.

  11. A System for Compressive Spectral and Polarization Imaging at Short Wave Infrared (SWIR) Wavelengths

    Science.gov (United States)

    2017-10-18

    UV -­‐ VIS -­‐IR   60mm   Apo   Macro  lens   Jenoptik-­‐Inc   $5,817.36   IR... VIS /NIR Compressive Spectral Imager”, Proceedings of IEEE International Conference on Image Processing (ICIP ’15), Quebec City, Canada, (September...imaging   system   will   lead   to   a   wide-­‐band   VIS -­‐NIR-­‐SWIR   compressive  spectral  and  polarimetric

  12. Manual compression and reflex syncope in native renal biopsy.

    Science.gov (United States)

    Takeuchi, Yoichi; Ojima, Yoshie; Kagaya, Saeko; Aoki, Satoshi; Nagasawa, Tasuku

    2018-03-14

    Complications associated with diagnostic native percutaneous renal biopsy (PRB) must be minimized. While life threatening major complications has been extensively investigated, there is little discussion regarding minor bleeding complications, such as a transient hypotension, which directly affect patients' quality of life. There is also little evidence supporting the need for conventional manual compression following PRB. Therefore, this study evaluated the relationship between minor and major complications incidence in patients following PRB with or without compression. This single-center, retrospective study included 456 patients (compression group: n = 71; observation group: n = 385). The compression group completed 15 min of manual compression and 4 h of subsequent strict bed rest with abdominal bandage. The observation group completed 2 h of strict bed rest only. The primary outcome of interest was transient symptomatic hypotension (minor event). Of the 456 patients, 26 patients encountered intraoperative and postoperative transient hypotension, which were considered reflex syncope without tachycardia. Univariate analysis showed that symptomatic transient hypotension was significantly associated with compression. This association remained significant, even after adjustment of covariates using multivariate logistic regression analysis (adjusted odds ratio 3.27; 95% confidential interval 1.36-7.82; P = 0.0078). Manual compression and abdominal bandage significantly increased the frequency of reflex syncope during native PRB. It is necessary to consider the potential benefit and risk of compression maneuvers for each patient undergoing this procedure.

  13. Optimization of multi-phase compressible lattice Boltzmann codes on massively parallel multi-core systems

    NARCIS (Netherlands)

    Biferale, L.; Mantovani, F.; Pivanti, M.; Pozzati, F.; Sbragaglia, M.; Schifano, S.F.; Toschi, F.; Tripiccione, R.

    2011-01-01

    We develop a Lattice Boltzmann code for computational fluid-dynamics and optimize it for massively parallel systems based on multi-core processors. Our code describes 2D multi-phase compressible flows. We analyze the performance bottlenecks that we find as we gradually expose a larger fraction of

  14. Maximal dissipation and well-posedness for the compressible Euler system

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard

    2014-01-01

    Roč. 16, č. 3 (2014), s. 447-461 ISSN 1422-6928 EU Projects: European Commission(XE) 320078 - MATHEF Keywords : maximal dissipation * compressible Euler system * weak solution Subject RIV: BA - General Mathematics Impact factor: 1.186, year: 2014 http://link.springer.com/article/10.1007/s00021-014-0163-8

  15. Dissipative solutions and the incompressible inviscid limits of the compressible magnetohydrodynamic system in unbounded domains

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Novotný, A.; Sun, Y.

    2014-01-01

    Roč. 34, č. 1 (2014), s. 121-143 ISSN 1078-0947 R&D Projects: GA ČR GA201/09/0917 Institutional support: RVO:67985840 Keywords : compressible MHD system * inviscid limit * incompressible limit Subject RIV: BA - General Mathematics Impact factor: 0.826, year: 2014 http://aimsciences.org/journals/displayArticlesnew.jsp?paperID=8717

  16. PET image reconstruction with rotationally symmetric polygonal pixel grid based highly compressible system matrix

    International Nuclear Information System (INIS)

    Yu Yunhan; Xia Yan; Liu Yaqiang; Wang Shi; Ma Tianyu; Chen Jing; Hong Baoyu

    2013-01-01

    To achieve a maximum compression of system matrix in positron emission tomography (PET) image reconstruction, we proposed a polygonal image pixel division strategy in accordance with rotationally symmetric PET geometry. Geometrical definition and indexing rule for polygonal pixels were established. Image conversion from polygonal pixel structure to conventional rectangular pixel structure was implemented using a conversion matrix. A set of test images were analytically defined in polygonal pixel structure, converted to conventional rectangular pixel based images, and correctly displayed which verified the correctness of the image definition, conversion description and conversion of polygonal pixel structure. A compressed system matrix for PET image recon was generated by tap model and tested by forward-projecting three different distributions of radioactive sources to the sinogram domain and comparing them with theoretical predictions. On a practical small animal PET scanner, a compress ratio of 12.6:1 of the system matrix size was achieved with the polygonal pixel structure, comparing with the conventional rectangular pixel based tap-mode one. OS-EM iterative image reconstruction algorithms with the polygonal and conventional Cartesian pixel grid were developed. A hot rod phantom was detected and reconstructed based on these two grids with reasonable time cost. Image resolution of reconstructed images was both 1.35 mm. We conclude that it is feasible to reconstruct and display images in a polygonal image pixel structure based on a compressed system matrix in PET image reconstruction. (authors)

  17. Compressive system identification of LTI and LTV ARX models: The limited data set case

    NARCIS (Netherlands)

    Sanandaij, B. M.; Vincent, T. L.; Wakin, M. B.; Toth, R.; Poolla, K.

    2011-01-01

    In this paper, we consider identifying Auto Regressive with eXternal input (ARX) models for both Linear Time-Invariant (LTI) and Linear Time-Variant (LTV) systems. We aim at doing the identification from the smallest possible number of observations. This is inspired by the field of Compressive

  18. A control oriental model for combined compression-ejector refrigeration system

    International Nuclear Information System (INIS)

    Liu, Jiapeng; Wang, Lei; Jia, Lei; Li, Zhen; Zhao, Hongxia

    2017-01-01

    Highlights: • A control oriental model for combined compression-ejector refrigeration system is proposed. • The pressure pulsating phenomenon in the system is investigated based on the model. • The results show that the model can reflect the system performance under variable operating conditions. - Abstract: Combined compression-ejector refrigeration systems have attracted lots of attention in recent years. In order to improve the running stability of the complex refrigeration system, it is necessary to obtain a simple and accuracy mathematical model for system control. In this paper, a control oriental model for combined compression ejector system is proposed. By analyzing the inner relationship between compressor and ejector, a hybrid model is built based on thermodynamic principles and lumped parameter method. Comparing with traditional theoretical models, the model is more suitable for system control due to its simpler structure and less parameters. Then the pressure pulsating phenomenon inside the piping system between compressor and ejector is investigated based on the model. The effectiveness of the proposed model is validated by experimental data. It is shown that the model can reflect the system performance under variable operating conditions.

  19. Design and Analysis of a Solar-Powered Compressed Air Energy Storage System

    Science.gov (United States)

    2016-12-01

    sized PV panel arrays. Kim et al. [49] and Manfrida et al. [50] proposed that a SS-AA- CAES system using COTS parts could be made more economical by...directly improve system efficiency. Furthermore, the power formulas derived using this approach can easily be used to both size the compressor based on...48] Villela, D., Kasinathan, V., De Valle, S., 2010, “Compressed-Air Energy Storage Systems for Stand-Alone Off-Grid Photovoltaic Modules

  20. Conceptual design of bend, compression, and final focus components of ILSE [Induction Linac System Experiment

    International Nuclear Information System (INIS)

    Lee, E.P.; Fong, C.; Mukherjee, S.; Thur, W.

    1989-03-01

    The Induction Linac System Experiment (ILSE) includes a 180/degree/ bend system, drift compression line and a final focus, which test the analogous features of a heavy ion driver for inertial fusion. These components are novel in their transport of a space-charge-dominated ion beam with large head-to-tail velocity tilt. Their conceptual design is presented, including calculations of the beam envelope, momentum dispersion, and engineering design of magnets, vacuum system, diagnostics, alignment, and support. 3 refs., 5 figs

  1. Feasibility study of polyurethane shape-memory polymer actuators for pressure bandage application

    International Nuclear Information System (INIS)

    Ahmad, Manzoor; Luo Jikui; Miraftab, Mohsen

    2012-01-01

    The feasibility of laboratory-synthesized polyurethane-based shape-memory polymer (SMPU) actuators has been investigated for possible application in medical pressure bandages where gradient pressure is required between the ankle and the knee for treatment of leg ulcers. In this study, using heat as the stimulant, SMPU strip actuators have been subjected to gradual and cyclic stresses; their recovery force, reproducibility and reusability have been monitored with respect to changes in temperature and circumference of a model leg, and the stress relaxation at various temperatures has been investigated. The findings suggest that SMPU actuators can be used for the development of the next generation of pressure bandages.

  2. Feasibility study of polyurethane shape-memory polymer actuators for pressure bandage application.

    Science.gov (United States)

    Ahmad, Manzoor; Luo, Jikui; Miraftab, Mohsen

    2012-02-01

    The feasibility of laboratory-synthesized polyurethane-based shape-memory polymer (SMPU) actuators has been investigated for possible application in medical pressure bandages where gradient pressure is required between the ankle and the knee for treatment of leg ulcers. In this study, using heat as the stimulant, SMPU strip actuators have been subjected to gradual and cyclic stresses; their recovery force, reproducibility and reusability have been monitored with respect to changes in temperature and circumference of a model leg, and the stress relaxation at various temperatures has been investigated. The findings suggest that SMPU actuators can be used for the development of the next generation of pressure bandages.

  3. Hybrid compression of video with graphics in DTV communication systems

    NARCIS (Netherlands)

    Schaar, van der M.; With, de P.H.N.

    2000-01-01

    Advanced broadcast manipulation of TV sequences and enhanced user interfaces for TV systems have resulted in an increased amount of pre- and post-editing of video sequences, where graphical information is inserted. However, in the current broadcasting chain, there are no provisions for enabling an

  4. Compressive Feedback Control Design for Spatially Distributed Systems

    Science.gov (United States)

    2017-01-03

    these notions and results to investigate a general form of combinatorial problem of growing a linear consensus network via minimizing a given systemic... combinatorial problem is derived that assist us to evaluate optimality gaps of our proposed algorithms. A detailed complexity analysis confirms the...performance and robustness in large-scale dynamical networks. Our goal was to discover and quantify a variety of mathematical (Heisenberg-like

  5. Some safety aspects of CO2 vapour compression systems

    Energy Technology Data Exchange (ETDEWEB)

    Pettersen, J. [Department of Refrigeration and Air Conditioning, Norwegian University of Science and Technology NTNU, Trondheim (Norway); Hafner, A.; Braanaas, M. [SINTEF Energy Research, Refrigeration and Air Conditioning, Trondheim (Norway)

    2000-11-01

    Since CO2 is a non-toxic and non-flammable refrigerant, the major safety issues for CO2 systems are related to the high operating pressure. In case of a component rupture, the explosion energy (stored energy) may characterise the extent of potential damage.The explosion energy can be estimated based on component (refrigerant-side) volumes, pressures and refrigerant property data. The explosion (stored) energies of baseline systems and CO2 systems are calculated and compared. Results show that the explosion energies are not as different as the large difference in pressure would indicate. It has been suggested that a Boiling Liquid Expanding Vapour Explosion (BLEVE) may occur when a vessel containing pressurised liquid or supercritical fluid is rapidly depressurised, e.g. due to a crack or a rupture. The overpressure from a BLEVE may be high enough to rupture the whole vessel, with a resulting blast wave and risk of flying fragments. Some tests on CO2 have been conducted at varying initial conditions and liquid fill levels, and with varying vent areas. No significant overpressure peaks above the initial pressure has been observed in the current test programme. 19 refs.

  6. Thermodynamic Analysis of Three Compressed Air Energy Storage Systems: Conventional, Adiabatic, and Hydrogen-Fueled

    Directory of Open Access Journals (Sweden)

    Hossein Safaei

    2017-07-01

    Full Text Available We present analyses of three families of compressed air energy storage (CAES systems: conventional CAES, in which the heat released during air compression is not stored and natural gas is combusted to provide heat during discharge; adiabatic CAES, in which the compression heat is stored; and CAES in which the compression heat is used to assist water electrolysis for hydrogen storage. The latter two methods involve no fossil fuel combustion. We modeled both a low-temperature and a high-temperature electrolysis process for hydrogen production. Adiabatic CAES (A-CAES with physical storage of heat is the most efficient option with an exergy efficiency of 69.5% for energy storage. The exergy efficiency of the conventional CAES system is estimated to be 54.3%. Both high-temperature and low-temperature electrolysis CAES systems result in similar exergy efficiencies (35.6% and 34.2%, partly due to low efficiency of the electrolyzer cell. CAES with high-temperature electrolysis has the highest energy storage density (7.9 kWh per m3 of air storage volume, followed by A-CAES (5.2 kWh/m3. Conventional CAES and CAES with low-temperature electrolysis have similar energy densities of 3.1 kWh/m3.

  7. Simulating coupled dynamics of a rigid-flexible multibody system and compressible fluid

    Science.gov (United States)

    Hu, Wei; Tian, Qiang; Hu, HaiYan

    2018-04-01

    As a subsequent work of previous studies of authors, a new parallel computation approach is proposed to simulate the coupled dynamics of a rigid-flexible multibody system and compressible fluid. In this approach, the smoothed particle hydrodynamics (SPH) method is used to model the compressible fluid, the natural coordinate formulation (NCF) and absolute nodal coordinate formulation (ANCF) are used to model the rigid and flexible bodies, respectively. In order to model the compressible fluid properly and efficiently via SPH method, three measures are taken as follows. The first is to use the Riemann solver to cope with the fluid compressibility, the second is to define virtual particles of SPH to model the dynamic interaction between the fluid and the multibody system, and the third is to impose the boundary conditions of periodical inflow and outflow to reduce the number of SPH particles involved in the computation process. Afterwards, a parallel computation strategy is proposed based on the graphics processing unit (GPU) to detect the neighboring SPH particles and to solve the dynamic equations of SPH particles in order to improve the computation efficiency. Meanwhile, the generalized-alpha algorithm is used to solve the dynamic equations of the multibody system. Finally, four case studies are given to validate the proposed parallel computation approach.

  8. COMPASS: an Interoperable Personal Health System to Monitor and Compress Signals in Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Thomas Hofer

    2015-11-01

    Full Text Available In the past years the progress on the mobile market has made possible an advancement in terms of telemedicine systems and definition of systems for monitoring chronic illnesses. The distribution of mobile devices in developed countries is increasing. Many of these devices are equipped with wireless standards including Bluetooth and the amount of sold Smartphones is constantly increasing. Our approach is oriented towards this market, using existing devices to enable in-home patient monitoring and even further to ubiquitious monitoring. The idea is to increase the quality of care, reduce costs and gather medical grade data, especially vital signs, with a resolution of minutes or even less, which is nowadays only possible in an ICU (Intensive Care Units. In this paper we will present the COMPASS personal health system (PHS platform, and how this platform enables Android devices to collect, analyze and send sensor data to an observation storage by means of interoperability standards. Furthermore, we will also present how this data can be compressed using advanced compressed sensing techniques and how to optimize these techniques with genetic algorithms to improve the RMSE of the reconstructed signal after compression. We also produce a preliminary evaluation of the algorithm against the state of the art algorithms for compressed sensing.

  9. Optimized Bunch Compression System for the European XFEL

    CERN Document Server

    Limberg, Torsten; Brinkmann, Reinhard; Decking, Winfried; Dohlus, Martin; Flöettmann, Klaus; Kim, Yujong; Schneidmiller, Evgeny

    2005-01-01

    The European XFEL bunch compressor system has been optimized for greater flexibility in parameter space. Operation beyond the XFEL design parameters is discussed in two directions: achieving the uppermost number of photons in a single pulse on one hand and reaching the necessary peak current for lasing with a pulse as short as possible on the other. Results of start-to-end calculations including 3D-CSR effects, space charge forces and the impact on wake fields demonstrate the potential of the XFEL for further improvement or, respectively, its safety margin for operation at design values.

  10. About local fractional three-dimensional compressible Navier-Stokes equations in Cantor-type cylindrical co-ordinate system

    Directory of Open Access Journals (Sweden)

    Gao Guo-Ping

    2016-01-01

    Full Text Available In this article, we investigate the local fractional 3-D compressible Navier-Stokes equation via local fractional derivative. We use the Cantor-type cylindrical co-ordinate method to transfer 3-D compressible Navier-Stokes equation from the Cantorian co-ordinate system to the Cantor-type cylindrical co-ordinate system.

  11. Firefighter's compressed air breathing system pressure vessel development program

    Science.gov (United States)

    Beck, E. J.

    1974-01-01

    The research to design, fabricate, test, and deliver a pressure vessel for the main component in an improved high-performance firefighter's breathing system is reported. The principal physical and performance characteristics of the vessel which were required are: (1) maximum weight of 9.0 lb; (2) maximum operating pressure of 4500 psig (charge pressure of 4000 psig); (3) minimum contained volume of 280 in. 3; (4) proof pressure of 6750 psig; (5) minimum burst pressure of 9000 psig following operational and service life; and (6) a minimum service life of 15 years. The vessel developed to fulfill the requirements described was completely sucessful, i.e., every category of performence was satisfied. The average weight of the vessel was found to be about 8.3 lb, well below the 9.0 lb specification requirement.

  12. Progress with lossy compression of data from the Community Earth System Model

    Science.gov (United States)

    Xu, H.; Baker, A.; Hammerling, D.; Li, S.; Clyne, J.

    2017-12-01

    Climate models, such as the Community Earth System Model (CESM), generate massive quantities of data, particularly when run at high spatial and temporal resolutions. The burden of storage is further exacerbated by creating large ensembles, generating large numbers of variables, outputting at high frequencies, and duplicating data archives (to protect against disk failures). Applying lossy compression methods to CESM datasets is an attractive means of reducing data storage requirements, but ensuring that the loss of information does not negatively impact science objectives is critical. In particular, test methods are needed to evaluate whether critical features (e.g., extreme values and spatial and temporal gradients) have been preserved and to boost scientists' confidence in the lossy compression process. We will provide an overview on our progress in applying lossy compression to CESM output and describe our unique suite of metric tests that evaluate the impact of information loss. Further, we will describe our processes how to choose an appropriate compression algorithm (and its associated parameters) given the diversity of CESM data (e.g., variables may be constant, smooth, change abruptly, contain missing values, or have large ranges). Traditional compression algorithms, such as those used for images, are not necessarily ideally suited for floating-point climate simulation data, and different methods may have different strengths and be more effective for certain types of variables than others. We will discuss our progress towards our ultimate goal of developing an automated multi-method parallel approach for compression of climate data that both maximizes data reduction and minimizes the impact of data loss on science results.

  13. Miniature Compressive Ultra-spectral Imaging System Utilizing a Single Liquid Crystal Phase Retarder

    Science.gov (United States)

    August, Isaac; Oiknine, Yaniv; Abuleil, Marwan; Abdulhalim, Ibrahim; Stern, Adrian

    2016-03-01

    Spectroscopic imaging has been proved to be an effective tool for many applications in a variety of fields, such as biology, medicine, agriculture, remote sensing and industrial process inspection. However, due to the demand for high spectral and spatial resolution it became extremely challenging to design and implement such systems in a miniaturized and cost effective manner. Using a Compressive Sensing (CS) setup based on a single variable Liquid Crystal (LC) retarder and a sensor array, we present an innovative Miniature Ultra-Spectral Imaging (MUSI) system. The LC retarder acts as a compact wide band spectral modulator. Within the framework of CS, a sequence of spectrally modulated images is used to recover ultra-spectral image cubes. Using the presented compressive MUSI system, we demonstrate the reconstruction of gigapixel spatio-spectral image cubes from spectral scanning shots numbering an order of magnitude less than would be required using conventional systems.

  14. Comparative study of air conditioning systems with vapor compression chillers using the concept of green buildings

    Directory of Open Access Journals (Sweden)

    Gutenberg da Silva Pereira

    2015-10-01

    Full Text Available This paper sets out to compare two different cooling systems that use vapor compression chillers for air conditioning environments. It was proposed to compare different operations in isolated and combined action operations. These operations are evaluated in the concepts of green buildings. A mathematical model was developed based on the principles of mass and energy conservation and complemented by various functions so as to determine the thermophysical properties and efficiencies of the compressors. The equations of the model were solved by the EES (Engineering Equation Solver program. The model evaluates the influence of the main HVAC operating parameters of the chilled water system when operating under three different configurations. The results showed that the system with a differentiated compression presents a COP equal to that of the system with screw chillers in the range  0-300 RTs, and a COP hat is on average 9% higher in the range 400-800 RTs.

  15. Integrating dynamic and distributed compressive sensing techniques to enhance image quality of the compressive line sensing system for unmanned aerial vehicles application

    Science.gov (United States)

    Ouyang, Bing; Hou, Weilin; Caimi, Frank M.; Dalgleish, Fraser R.; Vuorenkoski, Anni K.; Gong, Cuiling

    2017-07-01

    The compressive line sensing imaging system adopts distributed compressive sensing (CS) to acquire data and reconstruct images. Dynamic CS uses Bayesian inference to capture the correlated nature of the adjacent lines. An image reconstruction technique that incorporates dynamic CS in the distributed CS framework was developed to improve the quality of reconstructed images. The effectiveness of the technique was validated using experimental data acquired in an underwater imaging test facility. Results that demonstrate contrast and resolution improvements will be presented. The improved efficiency is desirable for unmanned aerial vehicles conducting long-duration missions.

  16. Modeling of Single and Dual Reservoir Porous Media Compressed Gas (Air and CO2) Storage Systems

    Science.gov (United States)

    Oldenburg, C. M.; Liu, H.; Borgia, A.; Pan, L.

    2017-12-01

    Intermittent renewable energy sources are causing increasing demand for energy storage. The deep subsurface offers promising opportunities for energy storage because it can safely contain high-pressure gases. Porous media compressed air energy storage (PM-CAES) is one approach, although the only facilities in operation are in caverns (C-CAES) rather than porous media. Just like in C-CAES, PM-CAES operates generally by injecting working gas (air) through well(s) into the reservoir compressing the cushion gas (existing air in the reservoir). During energy recovery, high-pressure air from the reservoir is mixed with fuel in a combustion turbine to produce electricity, thereby reducing compression costs. Unlike in C-CAES, the storage of energy in PM-CAES occurs variably across pressure gradients in the formation, while the solid grains of the matrix can release/store heat. Because air is the working gas, PM-CAES has fairly low thermal efficiency and low energy storage density. To improve the energy storage density, we have conceived and modeled a closed-loop two-reservoir compressed CO2 energy storage system. One reservoir is the low-pressure reservoir, and the other is the high-pressure reservoir. CO2 is cycled back and forth between reservoirs depending on whether energy needs to be stored or recovered. We have carried out thermodynamic and parametric analyses of the performance of an idealized two-reservoir CO2 energy storage system under supercritical and transcritical conditions for CO2 using a steady-state model. Results show that the transcritical compressed CO2 energy storage system has higher round-trip efficiency and exergy efficiency, and larger energy storage density than the supercritical compressed CO2 energy storage. However, the configuration of supercritical compressed CO2 energy storage is simpler, and the energy storage densities of the two systems are both higher than that of PM-CAES, which is advantageous in terms of storage volume for a given

  17. Point-Cloud Compression for Vehicle-Based Mobile Mapping Systems Using Portable Network Graphics

    Science.gov (United States)

    Kohira, K.; Masuda, H.

    2017-09-01

    A mobile mapping system is effective for capturing dense point-clouds of roads and roadside objects Point-clouds of urban areas, residential areas, and arterial roads are useful for maintenance of infrastructure, map creation, and automatic driving. However, the data size of point-clouds measured in large areas is enormously large. A large storage capacity is required to store such point-clouds, and heavy loads will be taken on network if point-clouds are transferred through the network. Therefore, it is desirable to reduce data sizes of point-clouds without deterioration of quality. In this research, we propose a novel point-cloud compression method for vehicle-based mobile mapping systems. In our compression method, point-clouds are mapped onto 2D pixels using GPS time and the parameters of the laser scanner. Then, the images are encoded in the Portable Networking Graphics (PNG) format and compressed using the PNG algorithm. In our experiments, our method could efficiently compress point-clouds without deteriorating the quality.

  18. POINT-CLOUD COMPRESSION FOR VEHICLE-BASED MOBILE MAPPING SYSTEMS USING PORTABLE NETWORK GRAPHICS

    Directory of Open Access Journals (Sweden)

    K. Kohira

    2017-09-01

    Full Text Available A mobile mapping system is effective for capturing dense point-clouds of roads and roadside objects.Point-clouds of urban areas, residential areas, and arterial roads are useful for maintenance of infrastructure, map creation, and automatic driving. However, the data size of point-clouds measured in large areas is enormously large. A large storage capacity is required to store such point-clouds, and heavy loads will be taken on network if point-clouds are transferred through the network. Therefore, it is desirable to reduce data sizes of point-clouds without deterioration of quality. In this research, we propose a novel point-cloud compression method for vehicle-based mobile mapping systems. In our compression method, point-clouds are mapped onto 2D pixels using GPS time and the parameters of the laser scanner. Then, the images are encoded in the Portable Networking Graphics (PNG format and compressed using the PNG algorithm. In our experiments, our method could efficiently compress point-clouds without deteriorating the quality.

  19. Channel coding and data compression system considerations for efficient communication of planetary imaging data

    Science.gov (United States)

    Rice, R. F.

    1974-01-01

    End-to-end system considerations involving channel coding and data compression are reported which could drastically improve the efficiency in communicating pictorial information from future planetary spacecraft. In addition to presenting new and potentially significant system considerations, this report attempts to fill a need for a comprehensive tutorial which makes much of this very subject accessible to readers whose disciplines lie outside of communication theory.

  20. Haptic Data Processing for Teleoperation Systems: Prediction, Compression and Error Correction

    OpenAIRE

    Lee, Jae-young

    2013-01-01

    This thesis explores haptic data processing methods for teleoperation systems, including prediction, compression, and error correction. In the proposed haptic data prediction method, unreliable network conditions, such as time-varying delay and packet loss, are detected by a transport layer protocol. Given the information from the transport layer, a Bayesian approach is introduced to predict position and force data in haptic teleoperation systems. Stability of the proposed method within stoch...

  1. Compact rf polarizer and its application to pulse compression systems

    Directory of Open Access Journals (Sweden)

    Matthew Franzi

    2016-06-01

    Full Text Available We present a novel method of reducing the footprint and increasing the efficiency of the modern multi-MW rf pulse compressor. This system utilizes a high power rf polarizer to couple two circular waveguide modes in quadrature to a single resonant cavity in order to replicate the response of a traditional two cavity configuration using a 4-port hybrid. The 11.424 GHz, high-Q, spherical cavity has a 5.875 cm radius and is fed by the circularly polarized signal to simultaneously excite the degenerate TE_{114} modes. The overcoupled spherical cavity has a Q_{0} of 9.4×10^{4} and coupling factor (β of 7.69 thus providing a loaded quality factor Q_{L} of 1.06×10^{4} with a fill time of 150 ns. Cold tests of the polarizer demonstrated good agreement with the numerical design, showing transmission of -0.05  dB and reflection back to the input rectangular WR 90 waveguide less than -40  dB over a 100 MHz bandwidth. This novel rf pulse compressor was tested at SLAC using XL-4 Klystron that provided rf power up to 32 MW and generated peak output power of 205 MW and an average of 135 MW over the discharged signal. A general network analysis of the polarizer is discussed as well as the design and high power test of the rf pulse compressor.

  2. A Scramjet Compression System for Hypersonic Air Transportation Vehicle Combined Cycle Engines

    Directory of Open Access Journals (Sweden)

    Devendra Sen

    2018-06-01

    Full Text Available This paper proposes a compression system for a scramjet, to be used as part of a combined cycle engine on a hypersonic transport vehicle that can achieve sustained flight at 8 Mach 8. Initially research into scramjet compression system and shock wave interaction was conducted to establish the foundation of the scramjet inlet and isolator sections. A Computational Fluid Dynamics (CFD campaign was conducted, where the shock structure and flow characteristics was analysed between Mach 4.5–8. The compression system of a scramjet is of crucial importance in providing air at suitable Mach number, pressure and temperature to the combustion chamber. The use of turbojet engines in over-under configuration with the scramjet was investigated as well as the study of a combined cycle scramjet-ramjet configuration. It was identified that locating the scramjet in the centre with a rotated ramjet on either side, where its ramps make up the scramjet wall was the most optimal configuration, as it mitigated the effect of the oblique shocks propagating from the scramjet walls into the adjacent ramjet. Furthermore, this meant that the forebody of the vehicle could solely be used as the compression surface by the scramjet. In this paper, the sizing of the scramjet combustion chamber and nozzle were modified to match the flow properties of the oncoming flow with the purpose of producing the most optimum scramjet configuration for the cruise speed of Mach 8. CFD simulations showed that the scramjet inlet did not provide the levels of compression and stagnation pressure recovery initially required. However, it was found that the scramjet provided significantly more thrust than the drag of the aircraft at sustained Mach 8 flight, due to its utilisation of a very aerodynamic vehicle design.

  3. A knitted glove sensing system with compression strain for finger movements

    Science.gov (United States)

    Ryu, Hochung; Park, Sangki; Park, Jong-Jin; Bae, Jihyun

    2018-05-01

    Development of a fabric structure strain sensor has received considerable attention due to its broad application in healthcare monitoring and human–machine interfaces. In the knitted textile structure, it is critical to understand the surface structural deformation from a different body motion, inducing the electrical signal characteristics. Here, we report the electromechanical properties of the knitted glove sensing system focusing on the compressive strain behavior. Compared with the electrical response of the tensile strain, the compressive strain shows much higher sensitivity, stability, and linearity via different finger motions. Additionally, the sensor exhibits constant electrical properties after repeated cyclic tests and washing processes. The proposed knitted glove sensing system can be readily extended to a scalable and cost-effective production due to the use of a commercialized manufacturing system.

  4. Compressed sensing based joint-compensation of power amplifier's distortions in OFDMA cognitive radio systems

    KAUST Repository

    Ali, Anum Z.

    2013-12-01

    Linearization of user equipment power amplifiers driven by orthogonal frequency division multiplexing signals is addressed in this paper. Particular attention is paid to the power efficient operation of an orthogonal frequency division multiple access cognitive radio system and realization of such a system using compressed sensing. Specifically, precompensated overdriven amplifiers are employed at the mobile terminal. Over-driven amplifiers result in in-band distortions and out of band interference. Out of band interference mostly occupies the spectrum of inactive users, whereas the in-band distortions are mitigated using compressed sensing at the receiver. It is also shown that the performance of the proposed scheme can be further enhanced using multiple measurements of the distortion signal in single-input multi-output systems. Numerical results verify the ability of the proposed setup to improve error vector magnitude, bit error rate, outage capacity and mean squared error. © 2011 IEEE.

  5. Compressed sensing based joint-compensation of power amplifier's distortions in OFDMA cognitive radio systems

    KAUST Repository

    Ali, Anum Z.; Hammi, Oualid; Al-Naffouri, Tareq Y.

    2013-01-01

    Linearization of user equipment power amplifiers driven by orthogonal frequency division multiplexing signals is addressed in this paper. Particular attention is paid to the power efficient operation of an orthogonal frequency division multiple access cognitive radio system and realization of such a system using compressed sensing. Specifically, precompensated overdriven amplifiers are employed at the mobile terminal. Over-driven amplifiers result in in-band distortions and out of band interference. Out of band interference mostly occupies the spectrum of inactive users, whereas the in-band distortions are mitigated using compressed sensing at the receiver. It is also shown that the performance of the proposed scheme can be further enhanced using multiple measurements of the distortion signal in single-input multi-output systems. Numerical results verify the ability of the proposed setup to improve error vector magnitude, bit error rate, outage capacity and mean squared error. © 2011 IEEE.

  6. Compressed sensing techniques for receiver based post-compensation of transmitter's nonlinear distortions in OFDM systems

    KAUST Repository

    Owodunni, Damilola S.

    2014-04-01

    In this paper, compressed sensing techniques are proposed to linearize commercial power amplifiers driven by orthogonal frequency division multiplexing signals. The nonlinear distortion is considered as a sparse phenomenon in the time-domain, and three compressed sensing based algorithms are presented to estimate and compensate for these distortions at the receiver using a few and, at times, even no frequency-domain free carriers (i.e. pilot carriers). The first technique is a conventional compressed sensing approach, while the second incorporates a priori information about the distortions to enhance the estimation. Finally, the third technique involves an iterative data-aided algorithm that does not require any pilot carriers and hence allows the system to work at maximum bandwidth efficiency. The performances of all the proposed techniques are evaluated on a commercial power amplifier and compared. The error vector magnitude and symbol error rate results show the ability of compressed sensing to compensate for the amplifier\\'s nonlinear distortions. © 2013 Elsevier B.V.

  7. Local System Matrix Compression for Efficient Reconstruction in Magnetic Particle Imaging

    Directory of Open Access Journals (Sweden)

    T. Knopp

    2015-01-01

    Full Text Available Magnetic particle imaging (MPI is a quantitative method for determining the spatial distribution of magnetic nanoparticles, which can be used as tracers for cardiovascular imaging. For reconstructing a spatial map of the particle distribution, the system matrix describing the magnetic particle imaging equation has to be known. Due to the complex dynamic behavior of the magnetic particles, the system matrix is commonly measured in a calibration procedure. In order to speed up the reconstruction process, recently, a matrix compression technique has been proposed that makes use of a basis transformation in order to compress the MPI system matrix. By thresholding the resulting matrix and storing the remaining entries in compressed row storage format, only a fraction of the data has to be processed when reconstructing the particle distribution. In the present work, it is shown that the image quality of the algorithm can be considerably improved by using a local threshold for each matrix row instead of a global threshold for the entire system matrix.

  8. Effect of Common Faults on the Performance of Different Types of Vapor Compression Systems.

    Science.gov (United States)

    Du, Zhimin; Domanski, Piotr A; Payne, W Vance

    2016-04-05

    The effect of faults on the cooling capacity, coefficient of performance, and sensible heat ratio, was analyzed and compared for five split and rooftop systems, which use different types of expansion devices, compressors and refrigerants. The study applied multivariable polynomial and normalized performance models, which were developed for the studied systems for both fault-free and faulty conditions based on measurements obtained in a laboratory under controlled conditions. The analysis indicated differences in responses and trends between the studied systems, which underscores the challenge to devise a universal FDD algorithm for all vapor compression systems and the difficulty to develop a methodology for rating the performance of different FDD algorithms.

  9. Subcooled compressed air energy storage system for coproduction of heat, cooling and electricity

    International Nuclear Information System (INIS)

    Arabkoohsar, A.; Dremark-Larsen, M.; Lorentzen, R.; Andresen, G.B.

    2017-01-01

    Highlights: •A new configuration of compressed air energy storage system is proposed and analyzed. •This system, so-called subcooled-CAES, offers cogeneration of electricity, heat and cooling. •A pseudo-dynamic energy, exergy and economic analysis of the system for an entire year is presented. •The annual power, cooling and heat efficiencies of the system are around 31%, 32% and 92%. •The overall energy and exergy performance coefficients of the system are 1.55 and 0.48, respectively. -- Abstract: Various configurations of compressed air energy storage technology have received attention over the last years due to the advantages that this technology offers relative to other power storage technologies. This work proposes a new configuration of this technology aiming at cogeneration of electricity, heat and cooling. The new system may be very advantageous for locations with high penetration of renewable energy in the electricity grid as well as high heating and cooling demands. The latter would typically be locations with district heating and cooling networks. A thorough design, sizing and thermodynamic analysis of the system for a typical wind farm with 300 MW capacity in Denmark is presented. The results show a great potential of the system to support the local district heating and cooling networks and reserve services in electricity market. The values of power-to-power, power-to-cooling and power-to-heat efficiencies of this system are 30.6%, 32.3% and 92.4%, respectively. The exergy efficiency values are 30.6%, 2.5% and 14.4% for power, cooling and heat productions. A techno-economic comparison of this system with two of the most efficient previous designs of compressed air energy storage system proves the firm superiority of the new concept.

  10. Retrofit device to improve vapor compression cooling system performance by dynamic blower speed modulation

    Science.gov (United States)

    Roth, Robert Paul; Hahn, David C.; Scaringe, Robert P.

    2015-12-08

    A device and method are provided to improve performance of a vapor compression system using a retrofittable control board to start up the vapor compression system with the evaporator blower initially set to a high speed. A baseline evaporator operating temperature with the evaporator blower operating at the high speed is recorded, and then the device detects if a predetermined acceptable change in evaporator temperature has occurred. The evaporator blower speed is reduced from the initially set high speed as long as there is only a negligible change in the measured evaporator temperature and therefore a negligible difference in the compressor's power consumption so as to obtain a net increase in the Coefficient of Performance.

  11. Commissioning and operating experience of compressed air system of a reprocessing plant (Paper No. 5.10)

    International Nuclear Information System (INIS)

    Nair, M.K.T.; Bajpai, D.D.; Mishra, A.K.; Kulkarni, H.B.; Raje, R.V.; Rajeshwar, S.

    1992-01-01

    Compressed air system is one of the most important utility systems, required in the continued operation of a radiochemical plant. Moisture and oil free compressed air is used in large scale for process control and process operations in reprocessing plants. Commissioning and operating experience of this system is described in detail, to indicate the importance of the system in the overall design and operation of such chemical plant. (author). 1 tab

  12. Efficient Bayesian Compressed Sensing-based Channel Estimation Techniques for Massive MIMO-OFDM Systems

    OpenAIRE

    Al-Salihi, Hayder Qahtan Kshash; Nakhai, Mohammad Reza

    2017-01-01

    Efficient and highly accurate channel state information (CSI) at the base station (BS) is essential to achieve the potential benefits of massive multiple input multiple output (MIMO) systems. However, the achievable accuracy that is attainable is limited in practice due to the problem of pilot contamination. It has recently been shown that compressed sensing (CS) techniques can address the pilot contamination problem. However, CS-based channel estimation requires prior knowledge of channel sp...

  13. Robustness of strong solutions to the compressible Navier-Stokes system

    Czech Academy of Sciences Publication Activity Database

    Bella, P.; Feireisl, Eduard; Jin, B.J.; Novotný, A.

    2015-01-01

    Roč. 362, 1-2 (2015), s. 281-303 ISSN 0025-5831 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : compressible Navier-Stokes system * smooth solution * stability Subject RIV: BA - General Mathematics Impact factor: 1.366, year: 2015 http://link.springer.com/article/10.1007%2Fs00208-014-1119-2

  14. Local strong solutions to the stochastic compressible Navier-Stokes system

    Czech Academy of Sciences Publication Activity Database

    Breit, D.; Feireisl, Eduard; Hofmanová, M.

    2018-01-01

    Roč. 43, č. 2 (2018), s. 313-345 ISSN 0360-5302 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : compressible fluids * local strong solutions * Navier-Stokes system Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 1.608, year: 2016 https://www.tandfonline.com/doi/full/10.1080/03605302.2018.1442476

  15. Energic, Exergic, Exergo‐economic investigation and optimization of auxiliary cooling system (ACS equipped with compression refrigerating system (CRS

    Directory of Open Access Journals (Sweden)

    Omid Karimi Sadaghiyani

    2017-09-01

    Full Text Available Heller main cooling tower as air-cooled heat exchanger is used in the combined cycle power plants (CCPP to reduce the temperature of condenser. In extreme summer heat, the efficiency of the cooling tower is reduced and it lessens performance of Steam Turbine Generation (STG unit of Combined Cycle Power Plant (CCPP. Thus, the auxiliary cooling system (ACS is equipped with compression refrigerating system (CRS. This auxiliary system is linked with the Heller main cooling tower and improves the performance of power plant. In other words, this auxiliary system increases the generated power of STG unit of CCPP by decreasing the temperature of returning water from cooling tower Therefore, in the first step, the mentioned auxiliary cooling system (ACS as a heat exchanger and compression refrigerating system (CRS have been designed via ASPEN HTFS and EES code respectively. In order to validate their results, these two systems have been built and theirs experimentally obtained data have been compared with ASPEN and EES results. There are good agreements between results. After that, exergic and exergo-economic analysis of designed systems have been carried out. Finally, the compression refrigerating system (CRS has been optimized via Genetic Algorithm (GA. Increasing in exergy efficiency (ε from 14.23% up to 36.12% and decreasing the total cost rate (ĊSystem from 378.2 ($/h to 308.2 ($/h are as results of multi-objective optimization.

  16. Thermodynamic analysis of a compressed carbon dioxide energy storage system using two saline aquifers at different depths as storage reservoirs

    International Nuclear Information System (INIS)

    Liu, Hui; He, Qing; Borgia, Andrea; Pan, Lehua; Oldenburg, Curtis M.

    2016-01-01

    Highlights: • A compressed CO_2 energy storage system using two storage reservoirs is presented. • Compressed CO_2 energy storage density is higher than that of CAES. • The effects of storage reservoir pressure on the system performance are studied. - Abstract: Compressed air energy storage (CAES) is one of the leading large-scale energy storage technologies. However, low thermal efficiency and low energy storage density restrict its application. To improve the energy storage density, we propose a two-reservoir compressed CO_2 energy storage system. We present here thermodynamic and parametric analyses of the performance of an idealized two-reservoir CO_2 energy storage system under supercritical and transcritical conditions using a steady-state mathematical model. Results show that the transcritical compressed CO_2 energy storage system has higher round-trip efficiency and exergy efficiency, and larger energy storage density than the supercritical compressed CO_2 energy storage. However, the configuration of supercritical compressed CO_2 energy storage is simpler, and the energy storage densities of the two systems are both higher than that of CAES, which is advantageous in terms of storage volume for a given power rating.

  17. Thermodynamic characteristics of a novel supercritical compressed air energy storage system

    International Nuclear Information System (INIS)

    Guo, Huan; Xu, Yujie; Chen, Haisheng; Zhou, Xuezhi

    2016-01-01

    Highlights: • A novel supercritical compressed air energy storage system is proposed. • The energy density of SC-CAES is approximately 18 times larger than that of conventional CAES. • The characteristic of thermodynamics and exergy destruction is comprehensively analysed. • The corresponding optimum relationship between charging and discharging pressure is illustrated. • A turning point of efficiency is indicated because of the heat transfer of crossing the critical point. - Abstract: A novel supercritical compressed air energy storage (SC-CAES) system is proposed by our team to solve the problems of conventional CAES. The system eliminates the dependence on fossil fuel and large gas-storage cavern, as well as possesses the advantages of high efficiency by employing the special properties of supercritical air, which is significant for the development of electrical energy storage. The thermodynamic model of the SC-CAES system is built, and the thermodynamic characters are revealed. Through the exergy analysis of the system, the processes of the larger exergy destruction include compression, expansion, cold storage/heat exchange and throttle. Furthermore, sensitivity analysis shows that there is an optimal energy releasing pressure to make the system achieve the highest efficiency when energy storage pressure is constant. The efficiency of SC-CAES is expected to reach about 67.41% when energy storage pressure and energy releasing pressure are 120 bar and 95.01 bar, respectively. At the same time, the energy density is 18 times larger than that of conventional CAES. Sensitivity analysis also shows the change laws of system efficiency varying with other basic system parameters. The study provides support for the design and engineering of SC-CAES.

  18. Cooling performance and energy saving of a compression-absorption refrigeration system assisted by geothermal energy

    International Nuclear Information System (INIS)

    Kairouani, L.; Nehdi, E.

    2006-01-01

    The objectives of this paper are to develop a novel combined refrigeration system, and to discuss the thermodynamic analysis of the cycle and the feasibility of its practical development. The aim of this work was to study the possibility of using geothermal energy to supply vapour absorption system cascaded with conventional compression system. Three working fluids (R717, R22, and R134a) are selected for the conventional compression system and the ammonia-water pair for the absorption system. The geothermal temperature source in the range 343-349 K supplies a generator operating at 335 K. Results show that the COP of a combined system is significantly higher than that of a single stage refrigeration system. It is found that the COP can be improved by 37-54%, compared with the conventional cycle, under the same operating conditions, that is an evaporation temperature at 263 K and a condensation temperature of 308 K. For industrial refrigeration, the proposed system constitutes an alternative solution for reducing energy consumption and greenhouse gas emissions

  19. An Adaptive Joint Sparsity Recovery for Compressive Sensing Based EEG System

    Directory of Open Access Journals (Sweden)

    Hamza Djelouat

    2017-01-01

    Full Text Available The last decade has witnessed tremendous efforts to shape the Internet of things (IoT platforms to be well suited for healthcare applications. These platforms are comprised of a network of wireless sensors to monitor several physical and physiological quantities. For instance, long-term monitoring of brain activities using wearable electroencephalogram (EEG sensors is widely exploited in the clinical diagnosis of epileptic seizures and sleeping disorders. However, the deployment of such platforms is challenged by the high power consumption and system complexity. Energy efficiency can be achieved by exploring efficient compression techniques such as compressive sensing (CS. CS is an emerging theory that enables a compressed acquisition using well-designed sensing matrices. Moreover, system complexity can be optimized by using hardware friendly structured sensing matrices. This paper quantifies the performance of a CS-based multichannel EEG monitoring. In addition, the paper exploits the joint sparsity of multichannel EEG using subspace pursuit (SP algorithm as well as a designed sparsifying basis in order to improve the reconstruction quality. Furthermore, the paper proposes a modification to the SP algorithm based on an adaptive selection approach to further improve the performance in terms of reconstruction quality, execution time, and the robustness of the recovery process.

  20. Design of a compressed air energy storage system for hydrostatic wind turbines

    Directory of Open Access Journals (Sweden)

    Ammar E. Ali

    2018-03-01

    Full Text Available Integration of Compressed Air Energy Storage (CAES system with a wind turbine is critical in optimally harvesting wind energy given the fluctuating nature of power demands. Here we consider the design of a CAES for a wind turbine with hydrostatic powertrain. The design parameters of the CAES are determined based on simulation of the integrated system model for a combination of these parameter values, namely the compression ratios of the air compressors and the expanders and the air tank size. The results of the simulations were used to choose the best design parameters, which would produce the best stable performance through increased energy output of the integrated CAES and wind turbine based on the intermittent wind profile. Simulation results for a 600 kW rated power wind turbine with integrated CAES indicate that increasing the tank size and compression ratio will improve the overall power quality through increased energy output up to a limit beyond which the power quality exhibits only marginal improvement.

  1. Performance comparison between a solar driven rotary desiccant cooling system and conventional vapor compression system (performance study of desiccant cooling)

    International Nuclear Information System (INIS)

    Ge, T.S.; Ziegler, F.; Wang, R.Z.; Wang, H.

    2010-01-01

    Solar driven rotary desiccant cooling systems have been widely recognized as alternatives to conventional vapor compression systems for their merits of energy-saving and being eco-friendly. In the previous paper, the basic performance features of desiccant wheel have been discussed. In this paper, a solar driven two-stage rotary desiccant cooling system and a vapor compression system are simulated to provide cooling for one floor in a commercial office building in two cities with different climates: Berlin and Shanghai. The model developed in the previous paper is adopted to predict the performance of the desiccant wheel. The objectives of this paper are to evaluate and compare the thermodynamic and economic performance of the two systems and to obtain useful data for practical application. Results show that the desiccant cooling system is able to meet the cooling demand and provide comfortable supply air in both of the two regions. The required regeneration temperatures are 55 deg. C in Berlin and 85 deg. C in Shanghai. As compared to the vapor compression system, the desiccant cooling system has better supply air quality and consumes less electricity. The results of the economic analysis demonstrate that the dynamic investment payback periods are 4.7 years in Berlin and 7.2 years in Shanghai.

  2. Evaluation of Two Compressed Air Foam Systems for Culling Caged Layer Hens

    Science.gov (United States)

    Weiher, Jaclyn A.; Alphin, Robert L.; Hougentogler, Daniel P.

    2018-01-01

    Simple Summary Control of avian influenza and similar diseases in commercial poultry operations is challenging; the six major steps are surveillance, biosecurity, quarantine, depopulation, disposal, and cleaning and disinfection. Depopulation is used to cull animals that are terminally ill and to reduce the number of animals that can spread an untreatable disease. Water-based foam depopulation was used effectively during the 2014–2015 highly pathogenic avian influenza outbreak in the United States. Water-based foam, however, cannot be used effectively in caged poultry operations. Compressed air foam systems were initially developed for structural fire-fighting and, with modifications, can provide the conditions required to effectively penetrate a poultry cage and provide sufficient residence time for depopulation. In this experiment, compressed air foam was used to depopulate caged layer hens. Compressed air foam resulted in faster unconsciousness than carbon dioxide gassing. The experiment demonstrated that compressed air foam systems have promise for depopulating birds raised in cages. Abstract Outbreaks of avian influenza (AI) and other highly contagious poultry diseases continue to be a concern for those involved in the poultry industry. In the situation of an outbreak, emergency depopulation of the birds involved is necessary. In this project, two compressed air foam systems (CAFS) were evaluated for mass emergency depopulation of layer hens in a manure belt equipped cage system. In both experiments, a randomized block design was used with multiple commercial layer hens treated with one of three randomly selected depopulation methods: CAFS, CAFS with CO2 gas, and CO2 gas. In Experiment 1, a Rowe manufactured CAFS was used, a selection of birds were instrumented, and the time to unconsciousness, brain death, altered terminal cardiac activity and motion cessation were recorded. CAFS with and without CO2 was faster to unconsciousness, however, the other

  3. A Novel Constant-Pressure Pumped Hydro Combined with Compressed Air Energy Storage System

    Directory of Open Access Journals (Sweden)

    Erren Yao

    2014-12-01

    Full Text Available As intermittent renewable energy is receiving increasing attention, the combination of intermittent renewable energy with large-scale energy storage technology is considered as an important technological approach for the wider application of wind power and solar energy. Pumped hydro combined with compressed air energy storage system (PHCA is one of the energy storage systems that not only integrates the advantages but also overcomes the disadvantages of compressed air energy storage (CAES systems and pumped hydro energy storage systems to solve the problem of energy storage in China’s arid regions. Aiming at the variable working conditions of PHCA system technology, this study proposes a new constant-pressure PHCA. The most significant characteristics of this system were that the water pump and hydroturbine work under stable conditions and this improves the working efficiency of the equipment without incurring an energy loss. In addition, the constant-pressure PHCA system was subjected to energy and exergy analysis, in expectation of exploring an attractive solution for the large-scale storage of existing intermittent renewable energy.

  4. Hybrid compression/absorption type heat utilization system (eco-energy city project)

    Energy Technology Data Exchange (ETDEWEB)

    Karimata, T.; Susami, S.; Ogawa, Y. [Research and Development Dept., EBARA Corp., Kanagawa pref. (Japan)

    1999-07-01

    This research is intended to develop a 'hybrid compression/absorption type heat utilization system' by combining an absorption process with a compression process in one circulation cycle. This system can produce chilling heat for ice thermal storage by utilizing low-temperature waste heat (lower than 100 C) which is impossible to treat with a conventional absorption chiller. It means that this system will be able to solve the problem of a timing mismatch between waste heat and heat demand. The working fluid used in this proposed system should be suitable for producing ice, be safe, and not damage the ozone layer. In this project, new working fluids were searched as substitutes for the existing H{sub 2}O/LiBr or NH{sub 3}/H{sub 2}O. The interim results of this project in 1997, a testing unit using NH{sub 3}/H{sub 2}O was built for demonstration of the system and evaluation of its characteristics, and R134a/E181 was found to be one of the good working fluid for this system. The COP (ratio of energy of ice produced to electric power provided) of this system using R134a/E181 is expected to achieve 5.5 by computer simulation. The testing unit with this working fluid was built recently and prepared for the tests to confirm the result of the simulation. (orig.)

  5. A theoretical global optimization method for vapor-compression refrigeration systems based on entransy theory

    International Nuclear Information System (INIS)

    Xu, Yun-Chao; Chen, Qun

    2013-01-01

    The vapor-compression refrigeration systems have been one of the essential energy conversion systems for humankind and exhausting huge amounts of energy nowadays. Surrounding the energy efficiency promotion of the systems, there are lots of effectual optimization methods but mainly relied on engineering experience and computer simulations rather than theoretical analysis due to the complex and vague physical essence. We attempt to propose a theoretical global optimization method based on in-depth physical analysis for the involved physical processes, i.e. heat transfer analysis for condenser and evaporator, through introducing the entransy theory and thermodynamic analysis for compressor and expansion valve. The integration of heat transfer and thermodynamic analyses forms the overall physical optimization model for the systems to describe the relation between all the unknown parameters and known conditions, which makes theoretical global optimization possible. With the aid of the mathematical conditional extremum solutions, an optimization equation group and the optimal configuration of all the unknown parameters are analytically obtained. Eventually, via the optimization of a typical vapor-compression refrigeration system with various working conditions to minimize the total heat transfer area of heat exchangers, the validity and superior of the newly proposed optimization method is proved. - Highlights: • A global optimization method for vapor-compression systems is proposed. • Integrating heat transfer and thermodynamic analyses forms the optimization model. • A mathematical relation between design parameters and requirements is derived. • Entransy dissipation is introduced into heat transfer analysis. • The validity of the method is proved via optimization of practical cases

  6. Automated control of a solar microgrid-powered air compressor for use in a small-scale compressed air energy storage system

    OpenAIRE

    Williams, Joshua N.

    2017-01-01

    Approved for public release; distribution is unlimited As part of the Office of Naval Research's study of advanced energy technologies, this research examined the development and implementation of a control system for the compression phase of a small-scale compressed air energy storage system, using a solar-powered microgrid to store energy as compressed air for later use. The compression system is composed of numerous commercial-off-the-shelf components wherever possible. All electronic c...

  7. Finite-size effects in thermodynamics: Negative compressibility and global instability in two-phase systems

    Science.gov (United States)

    Todoshchenko, I.

    2018-04-01

    We have measured the equilibrium melting pressure of helium-4 as a function of the crystal size. Negative compressibility of a liquid with an inclusion of solid seed is predicted theoretically and verified experimentally with helium-4 crystal-superfluid system at 0.15 K. This two-phase system is shown to be stable if the crystal size is large enough, which is proven by the experiment. Crystal seeds that are too small spontaneously either melt completely or grow to a large enough size.

  8. Modeling of Compressible Flow with Friction and Heat Transfer Using the Generalized Fluid System Simulation Program (GFSSP)

    Science.gov (United States)

    Bandyopadhyay, Alak; Majumdar, Alok

    2007-01-01

    The present paper describes the verification and validation of a quasi one-dimensional pressure based finite volume algorithm, implemented in Generalized Fluid System Simulation Program (GFSSP), for predicting compressible flow with friction, heat transfer and area change. The numerical predictions were compared with two classical solutions of compressible flow, i.e. Fanno and Rayleigh flow. Fanno flow provides an analytical solution of compressible flow in a long slender pipe where incoming subsonic flow can be choked due to friction. On the other hand, Raleigh flow provides analytical solution of frictionless compressible flow with heat transfer where incoming subsonic flow can be choked at the outlet boundary with heat addition to the control volume. Nonuniform grid distribution improves the accuracy of numerical prediction. A benchmark numerical solution of compressible flow in a converging-diverging nozzle with friction and heat transfer has been developed to verify GFSSP's numerical predictions. The numerical predictions compare favorably in all cases.

  9. A Novel Pumped Hydro Combined with Compressed Air Energy Storage System

    Directory of Open Access Journals (Sweden)

    Erren Yao

    2013-03-01

    Full Text Available A novel pumped hydro combined with compressed air energy storage (PHCA system is proposed in this paper to resolve the problems of bulk energy storage in the wind power generation industry over an area in China, which is characterised by drought and water shortages. Thermodynamic analysis of the energy storage system, which focuses on the pre-set pressure, storage volume capacity, water air volume ratio, pump performance, and water turbine performance of the storage system, is also presented. This paper discovers how such parameters affect the performance of the whole system. The ideal performance of this novel system has the following advantages: a simple, highly effective and low cost structure, which is comparable to the efficiency of a traditional pumped hydro storage system. Research results show a great solution to the current storage constraints encountered in the development of the wind power industry in China, which have been widely recognised as a bottleneck in the wind energy storage industry.

  10. Compressed Air Energy Storage System Control and Performance Assessment Using Energy Harvested Index

    Directory of Open Access Journals (Sweden)

    Hanif SedighNejad

    2014-01-01

    Full Text Available In this paper a new concept for control and performance assessment of compressed air energy storage (CAES systems in a hybrid energy system is introduced. The proposed criterion, based on the concept of energy harvest index (HEI, measures the capability of a storage system to capture renewable energy. The overall efficiency of the CAES system and optimum control and design from the technical and economic point of view is presented. A possible application of this idea is an isolated community with significant wind energy resource. A case study reveals the usefulness of the proposed criterion in design, control and implementation of a small CAES system in a hybrid power system (HPM for an isolated community. Energy harvested index and its effectiveness in increasing the wind penetration rate in the total energy production is discussed.

  11. Transmission Congestion Management using a Wind Integrated Compressed Air Energy Storage System

    Directory of Open Access Journals (Sweden)

    S. Gope

    2017-08-01

    Full Text Available Transmission congestion is a vital problem in the power system security and reliability sector. To ensure the stable operation of the system, a congestion free power network is desirable. In this paper, a new Congestion Management (CM technique, the Wind integrated Compressed Air Energy Storage (WCAES system is used to alleviate transmission congestion and to minimize congestion mitigation cost. The CM problem has been solved by using the Generator Sensitivity Factor (GSF and the Bus Sensitivity Factor (BSF. BSF is used for finding the optimal location of WCAES in the system. GSF with a Moth Flame Optimization (MFO algorithm is used for rescheduling the generators to alleviate congestion and to minimize congestion cost by improving security margin. The impact of the WCAES system is tested with a 39 bus system. To validate this approach, the same problem has been solved with a Particle Swarm Optimization (PSO algorithm and the obtained results are compared with the ones from the MFO algorithm.

  12. Experimental study on efficacy of compression systems with a high static stiffness index for treatment of venous ulcer patients

    OpenAIRE

    Anneke Andriessen; Martin Abel

    2013-01-01

    The experimental study measured interface pressure and static stiffness index of four different compression systems in fifty-two healthy volunteers. For the study interface pressure (3 cm ø probe was placed at the anatomical B1 point) was recorded on application of the compression systems every 15 min for 4 h, in supine, standing, while sitting and during walking. For this purpose a portable Kikuhime (Harada Corp., Osaka, Japan) device was used. Further static stiffness index (SSI) was...

  13. Comparison Between Bandage Contact Lenses and Pressure Patching on the Erosion Area and Pain Scale in Patients With Corneal Erosion.

    Science.gov (United States)

    Triharpini, Ni Nyoman; Gede Jayanegara, I Wayan; Handayani, Ariesanti Tri; Widiana, I Gde Raka

    2015-01-01

    Corneal erosion is common in eye emergency cases. Extensive corneal erosions result in severe pain and prolonged healing time. This study aimed to compare bandage contact lenses with pressure patching in terms of reducing the size of the erosion area, pain scale in patients with corneal erosion and its complications. A randomized open-label clinical trial was conducted. Subjects with mechanical corneal erosion were selected to use either bandage contact lenses or pressure patching. All subjects received antibiotic eye drops and 0.5% tropicamide eye drops. Evaluations were done 24 and 72 hours after treatment. The size of the corneal erosion area, pain scale, and complications were assessed. A total of 32 eyes (16 eyes in each group) were studied. The change in the size of the corneal erosion area was greater in the bandage contact lens group than in the pressure patching group, although there was no significant difference. In the bandage contact lens group, 56.25% of the eyes were healed at 24 hours and 43.75% were healed at 72 hours. In the pressure patching group, 62.50% were healed at 24 hours and 12.50% were healed at 72 hours. The change in pain scale was significantly greater in the bandage contact lens group than in the pressure patching group. No complications were found in both groups. Bandage contact lenses are an effective alternative to treating mechanical corneal erosion because of their effect in reducing pain without causing any complications.

  14. Parametric analysis of a combined dew point evaporative-vapour compression based air conditioning system

    Directory of Open Access Journals (Sweden)

    Shailendra Singh Chauhan

    2016-09-01

    Full Text Available A dew point evaporative-vapour compression based combined air conditioning system for providing good human comfort conditions at a low cost has been proposed in this paper. The proposed system has been parametrically analysed for a wide range of ambient temperatures and specific humidity under some reasonable assumptions. The proposed system has also been compared from the conventional vapour compression air conditioner on the basis of cooling load on the cooling coil working on 100% fresh air assumption. The saving of cooling load on the coil was found to be maximum with a value of 60.93% at 46 °C and 6 g/kg specific humidity, while it was negative for very high humidity of ambient air, which indicates that proposed system is applicable for dry and moderate humid conditions but not for very humid conditions. The system is working well with an average net monthly power saving of 192.31 kW h for hot and dry conditions and 124.38 kW h for hot and moderate humid conditions. Therefore it could be a better alternative for dry and moderate humid climate with a payback period of 7.2 years.

  15. Compression and release dynamics of an active matter system of Euglena gracilis

    Science.gov (United States)

    Lam, Amy; Tsang, Alan C. H.; Ouellette, Nicholas; Riedel-Kruse, Ingmar

    Active matter, defined as ensembles of self-propelled particles, encompasses a large variety of systems at all scales, from nanoparticles to bird flocks. Though various models and simulations have been created to describe the dynamics of these systems, experimental verification has been difficult to obtain. This is frequently due to the complex interaction rules which govern the particle behavior, in turn making systematic varying of parameters impossible. Here, we propose a model for predicting the system evolution of compression and release of an active system based on experiments and simulations. In particular, we consider ensembles of the unicellular, photo-responsive algae, Euglena gracilis, under light stimulation. By varying the spatiotemporal light patterns, we are able to finely adjust cell densities and achieve arbitrary non-homogeneous distributions, including compression into high-density aggregates of varying geometries. We observe the formation of depletion zones after the release of the confining stimulus and investigate the effects of the density distribution and particle rotational noise on the depletion. These results provide implications for defining state parameters which determine system evolution.

  16. Design and Simulation of a Vapour Compression Refrigeration System Using Phase Change Material

    Directory of Open Access Journals (Sweden)

    Siddharth Raju

    2018-01-01

    Full Text Available The paper details the design and simulation of a solar powered vapour compression refrigeration system. The effect of a phase change material, in this case ice, on a vapour compression refrigeration system powered by solar panels is discussed. The battery and solar panels were sized to allow the system to function as an autonomous unit for a minimum of 12 hours. It was concluded that the presence of a phase change material in the refrigeration system caused a considerable increase in both the on and off time of the compressor. The ratio by which the on time increased was greater than the ratio by which the off time was increased. There was a 219% increase in the on time, a 139% increase in the compressor off time and a 3.5% increase in compressor work accompanied by a 5.5% reduction in COP. Thus, under conditions where there is enough load in the system to cause the initial on and off times of the compressor to be comparable, the presence of a phase change material may result in a greater on period than an off period for the compressor.

  17. Fault Diagnosis for Hydraulic Servo System Using Compressed Random Subspace Based ReliefF

    Directory of Open Access Journals (Sweden)

    Yu Ding

    2018-01-01

    Full Text Available Playing an important role in electromechanical systems, hydraulic servo system is crucial to mechanical systems like engineering machinery, metallurgical machinery, ships, and other equipment. Fault diagnosis based on monitoring and sensory signals plays an important role in avoiding catastrophic accidents and enormous economic losses. This study presents a fault diagnosis scheme for hydraulic servo system using compressed random subspace based ReliefF (CRSR method. From the point of view of feature selection, the scheme utilizes CRSR method to determine the most stable feature combination that contains the most adequate information simultaneously. Based on the feature selection structure of ReliefF, CRSR employs feature integration rules in the compressed domain. Meanwhile, CRSR substitutes information entropy and fuzzy membership for traditional distance measurement index. The proposed CRSR method is able to enhance the robustness of the feature information against interference while selecting the feature combination with balanced information expressing ability. To demonstrate the effectiveness of the proposed CRSR method, a hydraulic servo system joint simulation model is constructed by HyPneu and Simulink, and three fault modes are injected to generate the validation data.

  18. Flow design and simulation of a gas compression system for hydrogen fusion energy production

    Energy Technology Data Exchange (ETDEWEB)

    Avital, E J; Salvatore, E [School of Engineering and Materials Science, Queen Mary University of London, Mile End Rd London E1 4NS (United Kingdom); Munjiza, A [Civil Engineering, University of Split, Livanjska 2100 Split (Croatia); Suponitsky, V; Plant, D; Laberge, M, E-mail: e.avital@qmul.ac.uk [General Fusion Inc.,108-3680 Bonneville Place, Burnaby, BC V3N 4T5 (Canada)

    2017-08-15

    An innovative gas compression system is proposed and computationally researched to achieve a short time response as needed in engineering applications such as hydrogen fusion energy reactors and high speed hammers. The system consists of a reservoir containing high pressure gas connected to a straight tube which in turn is connected to a spherical duct, where at the sphere’s centre plasma resides in the case of a fusion reactor. Diaphragm located inside the straight tube separates the reservoir’s high pressure gas from the rest of the plenum. Once the diaphragm is breached the high pressure gas enters the plenum to drive pistons located on the inner wall of the spherical duct that will eventually end compressing the plasma. Quasi-1D and axisymmetric flow formulations are used to design and analyse the flow dynamics. A spike is designed for the interface between the straight tube and the spherical duct to provide a smooth geometry transition for the flow. Flow simulations show high supersonic flow hitting the end of the spherical duct, generating a return shock wave propagating upstream and raising the pressure above the reservoir pressure as in the hammer wave problem, potentially giving temporary pressure boost to the pistons. Good agreement is revealed between the two flow formulations pointing to the usefulness of the quasi-1D formulation as a rapid solver. Nevertheless, a mild time delay in the axisymmetric flow simulation occurred due to moderate two-dimensionality effects. The compression system is settled down in a few milliseconds for a spherical duct of 0.8 m diameter using Helium gas and a uniform duct cross-section area. Various system geometries are analysed using instantaneous and time history flow plots. (paper)

  19. Flow design and simulation of a gas compression system for hydrogen fusion energy production

    Science.gov (United States)

    Avital, E. J.; Salvatore, E.; Munjiza, A.; Suponitsky, V.; Plant, D.; Laberge, M.

    2017-08-01

    An innovative gas compression system is proposed and computationally researched to achieve a short time response as needed in engineering applications such as hydrogen fusion energy reactors and high speed hammers. The system consists of a reservoir containing high pressure gas connected to a straight tube which in turn is connected to a spherical duct, where at the sphere’s centre plasma resides in the case of a fusion reactor. Diaphragm located inside the straight tube separates the reservoir’s high pressure gas from the rest of the plenum. Once the diaphragm is breached the high pressure gas enters the plenum to drive pistons located on the inner wall of the spherical duct that will eventually end compressing the plasma. Quasi-1D and axisymmetric flow formulations are used to design and analyse the flow dynamics. A spike is designed for the interface between the straight tube and the spherical duct to provide a smooth geometry transition for the flow. Flow simulations show high supersonic flow hitting the end of the spherical duct, generating a return shock wave propagating upstream and raising the pressure above the reservoir pressure as in the hammer wave problem, potentially giving temporary pressure boost to the pistons. Good agreement is revealed between the two flow formulations pointing to the usefulness of the quasi-1D formulation as a rapid solver. Nevertheless, a mild time delay in the axisymmetric flow simulation occurred due to moderate two-dimensionality effects. The compression system is settled down in a few milliseconds for a spherical duct of 0.8 m diameter using Helium gas and a uniform duct cross-section area. Various system geometries are analysed using instantaneous and time history flow plots.

  20. Jelly-like bandage helps heal wounds: Egypt develops hydrogels using irradiated polymers

    International Nuclear Information System (INIS)

    Dixit, Aabha

    2015-01-01

    Patients suffering from burn injuries, skin ulcers and bed sores can find relief using unique jelly-like materials — hydrogels — that are playing an increasingly vital role in the healing process of such wounds. Nuclear technology has been crucial in developing hydrogels that form an important part of treating wounds in many low and middle income countries including Egypt. The exceptional gel bandage is fast becoming ubiquitous to ‘cool’ wounds and reduce the painful effects of burns and other injuries. The wounds of diabetic patients have healed much faster and better than with traditional bandages, said El-Sayed A. Hegazy, Professor Emeritus and former Chairman of the National Centre for Radiation Research and Technology (NCRRT) of Egypt, the only facility in the country to develop hydrogels.

  1. Reliability analysis and optimisation of subsea compression system facing operational covariate stresses

    International Nuclear Information System (INIS)

    Okaro, Ikenna Anthony; Tao, Longbin

    2016-01-01

    This paper proposes an enhanced Weibull-Corrosion Covariate model for reliability assessment of a system facing operational stresses. The newly developed model is applied to a Subsea Gas Compression System planned for offshore West Africa to predict its reliability index. System technical failure was modelled by developing a Weibull failure model incorporating a physically tested corrosion profile as stress in order to quantify the survival rate of the system under additional operational covariates including marine pH, temperature and pressure. Using Reliability Block Diagrams and enhanced Fusell-Vesely formulations, the whole system was systematically decomposed to sub-systems to analyse the criticality of each component and optimise them. Human reliability was addressed using an enhanced barrier weighting method. A rapid degradation curve is obtained on a subsea system relative to the base case subjected to a time-dependent corrosion stress factor. It reveals that subsea system components failed faster than their Mean time to failure specifications from Offshore Reliability Database as a result of cumulative marine stresses exertion. The case study demonstrated that the reliability of a subsea system can be systematically optimised by modelling the system under higher technical and organisational stresses, prioritising the critical sub-systems and making befitting provisions for redundancy and tolerances. - Highlights: • Novel Weibull Corrosion-Covariate model for reliability analysis of subsea assets. • Predict the accelerated degradation profile of a subsea gas compression. • An enhanced optimisation method based on Fusell-Vesely decomposition process. • New optimisation approach for smoothening of over- and under-designed components. • Demonstrated a significant improvement in producing more realistic failure rate.

  2. Study on the influence of supplying compressed air channels and evicting channels on pneumatical oscillation systems for vibromooshing

    Science.gov (United States)

    Glăvan, D. O.; Radu, I.; Babanatsas, T.; Babanatis Merce, R. M.; Kiss, I.; Gaspar, M. C.

    2018-01-01

    The paper presents a pneumatic system with two oscillating masses. The system is composed of a cylinder (framework) with mass m1, which has a piston with mass m2 inside. The cylinder (framework system) has one supplying channel for compressed air and one evicting channel for each work chamber (left and right of the piston). Functionality of the piston position comparatively with the cylinder (framework) is possible through the supplying or evicting of compressed air. The variable force that keeps the movement depends on variation of the pressure that is changing depending on the piston position according to the cylinder (framework) and to the section form that is supplying and evicting channels with compressed air. The paper presents the physical model/pattern, the mathematical model/pattern (differential equations) and numerical solution of the differential equations in hypothesis with the section form of supplying and evicting channels with compressed air is rectangular (variation linear) or circular (variation nonlinear).

  3. Efficacy of night-time compression for breast cancer related lymphedema (LYNC): protocol for a multi-centre, randomized controlled efficacy trial

    International Nuclear Information System (INIS)

    McNeely, Margaret L.; Campbell, Kristin L.; Webster, Marc; Kuusk, Urve; Tracey, Karen; Mackey, John

    2016-01-01

    Lymphedema is a prevalent long-term effect of breast cancer treatment that is associated with reduced quality of life. More recent observational data suggest that the addition of night-time compression to day-time use of a compression garment results in better long-term control of arm lymphedema. The primary objectives of the randomized controlled phase of the trial are to determine the efficacy of night-time compression on arm lymphedema volume maintenance and quality of life in breast cancer survivors who have completed intensive reduction treatment for their lymphedema. The study will be a parallel 3-arm, multi-centre randomized fast-track trial. A total of 120 women with breast cancer related lymphedema will be recruited from 3 centres in Canada and randomized to group 1: Day-time compression garment alone or Group 2: Day-time compression garment + night-time compression bandaging or Group 3: Day-time compression garment + use of a night-time compression system garment. The duration of the primary intervention period will be 12 weeks. The follow-up period after the intervention (weeks 13 to 24) will follow a longitudinal observational design. The primary outcome variables: differences from baseline to week 12 in arm volume and quality of life (Lymphoedema Functioning, Disability and Health Questionnaire: Lymph-ICF). Secondary outcomes include bioimpedance analysis, sleep disturbance and self-efficacy. All measurements are standardized and will be performed prior to randomization, and at weeks 6, 12, 18 and 24. The use of night-time compression as a self-management strategy for chronic breast cancer related lymphedema is seen as an innovative approach to improve long-term control over the condition. This trial aims to advance the knowledge on self-management strategies for lymphedema

  4. Thermal System Analysis and Optimization of Large-Scale Compressed Air Energy Storage (CAES

    Directory of Open Access Journals (Sweden)

    Zhongguang Fu

    2015-08-01

    Full Text Available As an important solution to issues regarding peak load and renewable energy resources on grids, large-scale compressed air energy storage (CAES power generation technology has recently become a popular research topic in the area of large-scale industrial energy storage. At present, the combination of high-expansion ratio turbines with advanced gas turbine technology is an important breakthrough in energy storage technology. In this study, a new gas turbine power generation system is coupled with current CAES technology. Moreover, a thermodynamic cycle system is optimized by calculating for the parameters of a thermodynamic system. Results show that the thermal efficiency of the new system increases by at least 5% over that of the existing system.

  5. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  6. Combining nonlinear multiresolution system and vector quantization for still image compression

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Y.

    1993-12-17

    It is popular to use multiresolution systems for image coding and compression. However, general-purpose techniques such as filter banks and wavelets are linear. While these systems are rigorous, nonlinear features in the signals cannot be utilized in a single entity for compression. Linear filters are known to blur the edges. Thus, the low-resolution images are typically blurred, carrying little information. We propose and demonstrate that edge-preserving filters such as median filters can be used in generating a multiresolution system using the Laplacian pyramid. The signals in the detail images are small and localized to the edge areas. Principal component vector quantization (PCVQ) is used to encode the detail images. PCVQ is a tree-structured VQ which allows fast codebook design and encoding/decoding. In encoding, the quantization error at each level is fed back through the pyramid to the previous level so that ultimately all the error is confined to the first level. With simple coding methods, we demonstrate that images with PSNR 33 dB can be obtained at 0.66 bpp without the use of entropy coding. When the rate is decreased to 0.25 bpp, the PSNR of 30 dB can still be achieved. Combined with an earlier result, our work demonstrate that nonlinear filters can be used for multiresolution systems and image coding.

  7. Evaluation of Digital Compressed Sensing for Real-Time Wireless ECG System with Bluetooth low Energy.

    Science.gov (United States)

    Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan

    2016-07-01

    In this paper, a wearable and wireless ECG system is firstly designed with Bluetooth Low Energy (BLE). It can detect 3-lead ECG signals and is completely wireless. Secondly the digital Compressed Sensing (CS) is implemented to increase the energy efficiency of wireless ECG sensor. Different sparsifying basis, various compression ratio (CR) and several reconstruction algorithms are simulated and discussed. Finally the reconstruction is done by the android application (App) on smartphone to display the signal in real time. The power efficiency is measured and compared with the system without CS. The optimum satisfying basis built by 3-level decomposed db4 wavelet coefficients, 1-bit Bernoulli random matrix and the most suitable reconstruction algorithm are selected by the simulations and applied on the sensor node and App. The signal is successfully reconstructed and displayed on the App of smartphone. Battery life of sensor node is extended from 55 h to 67 h. The presented wireless ECG system with CS can significantly extend the battery life by 22 %. With the compact characteristic and long term working time, the system provides a feasible solution for the long term homecare utilization.

  8. Multilevel compression of random walks on networks reveals hierarchical organization in large integrated systems.

    Directory of Open Access Journals (Sweden)

    Martin Rosvall

    Full Text Available To comprehend the hierarchical organization of large integrated systems, we introduce the hierarchical map equation, which reveals multilevel structures in networks. In this information-theoretic approach, we exploit the duality between compression and pattern detection; by compressing a description of a random walker as a proxy for real flow on a network, we find regularities in the network that induce this system-wide flow. Finding the shortest multilevel description of the random walker therefore gives us the best hierarchical clustering of the network--the optimal number of levels and modular partition at each level--with respect to the dynamics on the network. With a novel search algorithm, we extract and illustrate the rich multilevel organization of several large social and biological networks. For example, from the global air traffic network we uncover countries and continents, and from the pattern of scientific communication we reveal more than 100 scientific fields organized in four major disciplines: life sciences, physical sciences, ecology and earth sciences, and social sciences. In general, we find shallow hierarchical structures in globally interconnected systems, such as neural networks, and rich multilevel organizations in systems with highly separated regions, such as road networks.

  9. Implementation of a compressive sampling scheme for wireless sensors to achieve energy efficiency in a structural health monitoring system

    Science.gov (United States)

    O'Connor, Sean M.; Lynch, Jerome P.; Gilbert, Anna C.

    2013-04-01

    Wireless sensors have emerged to offer low-cost sensors with impressive functionality (e.g., data acquisition, computing, and communication) and modular installations. Such advantages enable higher nodal densities than tethered systems resulting in increased spatial resolution of the monitoring system. However, high nodal density comes at a cost as huge amounts of data are generated, weighing heavy on power sources, transmission bandwidth, and data management requirements, often making data compression necessary. The traditional compression paradigm consists of high rate (>Nyquist) uniform sampling and storage of the entire target signal followed by some desired compression scheme prior to transmission. The recently proposed compressed sensing (CS) framework combines the acquisition and compression stage together, thus removing the need for storage and operation of the full target signal prior to transmission. The effectiveness of the CS approach hinges on the presence of a sparse representation of the target signal in a known basis, similarly exploited by several traditional compressive sensing applications today (e.g., imaging, MRI). Field implementations of CS schemes in wireless SHM systems have been challenging due to the lack of commercially available sensing units capable of sampling methods (e.g., random) consistent with the compressed sensing framework, often moving evaluation of CS techniques to simulation and post-processing. The research presented here describes implementation of a CS sampling scheme to the Narada wireless sensing node and the energy efficiencies observed in the deployed sensors. Of interest in this study is the compressibility of acceleration response signals collected from a multi-girder steel-concrete composite bridge. The study shows the benefit of CS in reducing data requirements while ensuring data analysis on compressed data remain accurate.

  10. Thermodynamic analysis of a novel hybrid wind-solar-compressed air energy storage system

    International Nuclear Information System (INIS)

    Ji, Wei; Zhou, Yuan; Sun, Yu; Zhang, Wu; An, Baolin; Wang, Junjie

    2017-01-01

    Highlights: • We present a novel hybrid wind-solar-compressed air energy storage system. • Wind and solar power are transformed into stable electric energy and hot water. • The system output electric power is 8053 kWh with an exergy efficiency of 65.4%. • Parametric sensitivity analysis is presented to optimize system performance. - Abstract: Wind and solar power have embraced a strong development in recent years due to the energy crisis in China. However, owing to their nature of fluctuation and intermittency, some power grid management problems can be caused. Therefore a novel hybrid wind-solar-compressed air energy storage (WS-CAES) system was proposed to solve the problems. The WS-CAES system can store unstable wind and solar power for a stable output of electric energy and hot water. Also, combined with organic Rankin cycle (ORC), the cascade utilization of energy with different qualities was achieved in the WS-CAES system. Aiming to obtain the optimum performance, the analysis of energy, exergy and parametric sensitivity were all conducted for this system. Furthermore, exergy destruction ratio of each component in the WS-CAES system was presented. The results show that the electric energy storage efficiency, round trip efficiency and exergy efficiency can reach 87.7%, 61.2% and 65.4%, respectively. Meanwhile, the parameters analysis demonstrates that the increase of ambient temperature has a negative effect on the system performance, while the increase of turbine inlet temperature has a positive effect. However, when the air turbine inlet pressure varies, there is a tradeoff between the system performance and the energy storage density.

  11. Wellhead compression

    Energy Technology Data Exchange (ETDEWEB)

    Harrington, Joe [Sertco Industries, Inc., Okemah, OK (United States); Vazquez, Daniel [Hoerbiger Service Latin America Inc., Deerfield Beach, FL (United States); Jacobs, Denis Richard [Hoerbiger do Brasil Industria de Equipamentos, Cajamar, SP (Brazil)

    2012-07-01

    Over time, all wells experience a natural decline in oil and gas production. In gas wells, the major problems are liquid loading and low downhole differential pressures which negatively impact total gas production. As a form of artificial lift, wellhead compressors help reduce the tubing pressure resulting in gas velocities above the critical velocity needed to surface water, oil and condensate regaining lost production and increasing recoverable reserves. Best results come from reservoirs with high porosity, high permeability, high initial flow rates, low decline rates and high total cumulative production. In oil wells, excessive annulus gas pressure tends to inhibit both oil and gas production. Wellhead compression packages can provide a cost effective solution to these problems by reducing the system pressure in the tubing or annulus, allowing for an immediate increase in production rates. Wells furthest from the gathering compressor typically benefit the most from wellhead compression due to system pressure drops. Downstream compressors also benefit from higher suction pressures reducing overall compression horsepower requirements. Special care must be taken in selecting the best equipment for these applications. The successful implementation of wellhead compression from an economical standpoint hinges on the testing, installation and operation of the equipment. Key challenges and suggested equipment features designed to combat those challenges and successful case histories throughout Latin America are discussed below.(author)

  12. An asymptotic preserving multidimensional ALE method for a system of two compressible flows coupled with friction

    Science.gov (United States)

    Del Pino, S.; Labourasse, E.; Morel, G.

    2018-06-01

    We present a multidimensional asymptotic preserving scheme for the approximation of a mixture of compressible flows. Fluids are modelled by two Euler systems of equations coupled with a friction term. The asymptotic preserving property is mandatory for this kind of model, to derive a scheme that behaves well in all regimes (i.e. whatever the friction parameter value is). The method we propose is defined in ALE coordinates, using a Lagrange plus remap approach. This imposes a multidimensional definition and analysis of the scheme.

  13. Well-posedness for the compressible Navier–Stokes–Lamé system with a free interface

    International Nuclear Information System (INIS)

    Kukavica, Igor; Tuffaha, Amjad

    2012-01-01

    We address the system of fluid–structure interaction consisting of a compressible Navier–Stokes equation coupled with an elasticity equation, with the velocity and stress continuity requirements across the free moving interface. We prove the a priori estimates for existence of solutions when the initial velocity belongs to H 3 , the initial density is bounded from below and belongs to H 3/2+r , where r > 0, and the initial velocity of the displacement is in H 3/2+r . (paper)

  14. Pressure Regulators as Valves for Saving Compressed Air and their Influence on System Dynamics

    Directory of Open Access Journals (Sweden)

    Dvořák Lukáš

    2015-01-01

    Full Text Available Pressure regulators in the field of pneumatic mechanisms can be used as valves for saving compressed air. For example it can be used to reduce the pressure when the piston rod is retracting unloaded and thus it is possible to save some energy. However the problem is that saving valve can significantly affect the dynamics of the pneumatic system. The lower pressure in the piston rod chamber causes extension of time for retraction of the piston rod. This article compare the air consumption experimentally determined and calculated, measured curves of pressure in cylinder chambers and piston speed when saving valve is set up differently.

  15. Pressure Regulators as Valves for Saving Compressed Air and their Influence on System Dynamics

    Science.gov (United States)

    Dvořák, Lukáš; Fojtášek, Kamil

    2015-05-01

    Pressure regulators in the field of pneumatic mechanisms can be used as valves for saving compressed air. For example it can be used to reduce the pressure when the piston rod is retracting unloaded and thus it is possible to save some energy. However the problem is that saving valve can significantly affect the dynamics of the pneumatic system. The lower pressure in the piston rod chamber causes extension of time for retraction of the piston rod. This article compare the air consumption experimentally determined and calculated, measured curves of pressure in cylinder chambers and piston speed when saving valve is set up differently.

  16. Experimental Results Obtained with Air Liquide Cold Compression System CERN LHC and SNS Projects

    CERN Document Server

    Delcayre, F; Hamber, F; Hilbert, B; Monneret, E; Toia, J L

    2006-01-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high‐capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC wil...

  17. Compressed air energy storage system reservoir size for a wind energy baseload power plant

    Energy Technology Data Exchange (ETDEWEB)

    Cavallo, A.J.

    1996-12-31

    Wind generated electricity can be transformed from an intermittent to a baseload resource using an oversized wind farm in conjunction with a compressed air energy storage (CAES) system. The size of the storage reservoir for the CAES system (solution mined salt cavern or porous media) as a function of the wind speed autocorrelation time (C) has been examined using a Monte Carlo simulation for a wind class 4 (wind power density 450 W m{sup -2} at 50 m hub height) wind regime with a Weibull k factor of 2.5. For values of C typically found for winds over the US Great Plains, the storage reservoir must have a 60 to 80 hour capacity. Since underground reservoirs account for only a small fraction of total system cost, this larger storage reservoir has a negligible effect on the cost of energy from the wind energy baseload system. 7 refs., 2 figs., 1 tab.

  18. Experimental Study on Active Control of Surge in a Centrifugal Compression System

    Directory of Open Access Journals (Sweden)

    Nie Chaoqun

    2000-01-01

    Full Text Available An experimental study has been carried out on the active control of surge in a centrifugal compression system. With a computerized on-line control scheme, the surge phenomenon is suppressed and the stable operating range of the system is extended. In order to design the active control scheme and choose the desired parameters of the control system inputs, special emphases have been placed on the development of surge inception and the nonlinear interaction between the system and the actuator. By use of the method designed in the present work, the results of active control onsurge have been demonstrated for the different B parameters, different prescribed criteria and different control frequencies.

  19. The drive beam pulse compression system for the CLIC RF power source

    CERN Document Server

    Corsini, R

    1999-01-01

    The Compact LInear Collider (CLIC) is a high energy (0.5 to 5 TeV) e ± linear collider that uses a high- current electron beam (the drive beam) for 30 GHz RF power production by the Two-Beam Acceleration (TBA) method. Recently, a new cost­effective and efficient generation scheme for the drive beam has been developed. A fully­loaded normal­conducting linac operating at lower frequency (937 MHz) generates and accelerates the drive beam bunches, and a compression system composed of a delay­line and two combiner rings produces the proper drive beam time structure for RF power generation in the drive beam decelerator. In this paper, a preliminary design of the whole compression system is presented. In particular, the fundamental issue of preserving the bunch quality along the complex is studied and its impact on the beam parameters and on the various system components is assessed. A first design of the rings and delay­line lattice, including path length tuning chicanes, injection and extraction regions is a...

  20. Multimode seeded Richtmyer-Meshkov mixing in a convergent, compressible, miscible plasma system

    International Nuclear Information System (INIS)

    Lanier, N.E.; Barnes, Cris W.; Batha, S.H.; Day, R.D.; Magelssen, G.R.; Scott, J.M.; Dunne, A.M.; Parker, K.W.; Rothman, S.D.

    2003-01-01

    Richtmyer-Meshkov (RM) mixing seeded by multimode initial surface perturbations in a convergent, compressible, miscible plasma system is measured on the OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] laser system. A strong shock (Mach 12-20), created by 50 laser beams, is used to accelerate impulsively a thin aluminum shell into a lower density foam. As the system converges, both interfaces of the aluminum are RM unstable and undergo mixing. Standard x-ray radiographic techniques are employed to survey accurately the zero-order hydrodynamics, the average radius and overall width, of the marker. LASNEX [G. B. Zimmerman et al., Comments on Plasma Physics 2, 51 (1975)] simulations are consistent with the zero-order behavior of initially smooth markers. In experiments with smooth aluminum markers, the measured marker width shortly after shock passage behaves incompressibly and thickens due to Bell-Plesset effects. At high convergence (>4), the marker begins to compress as the rebounding shock passes back through the marker. When an initial multimode perturbation is introduced to the outer surface of the marker, the measured marker width is observed to increase by 10-15 μm, and is substantially smaller than as-shot simulations using RAGE [R. M. Baltrusaitis et al., Phys. Fluids 8, 2471 (1996)] would predict

  1. Economic study on compressed energy storage cogeneration system in urban areas

    International Nuclear Information System (INIS)

    Uchiyama, Youji

    1991-01-01

    Due to the concentration of functions into cities and the spread of room cooling facilities, the energy demand in cities increased rapidly especially in summer season. The improvement of load factor of electric power has become an important subject for electric power companies, and as the technology for positively improving it, there is electric power storage. As for compressed air energy storage (CAES) system, its introduction, has been investigated as the electric power storage technology for the future in electric power business, but since it is also gas turbine technology, it becomes a cogeneration system. If the waste heat of gas turbines and compressors can be utilized effectively, not only the load factor of electric power is improved, but also it contributes to the improvement of overall energy efficiency and the improvement of environmental problems. This research is to study on the feasibility of compressed air energy storage centering around its economical efficiency when it is installed in customer side as the cogeneration system in cities. The features of CAES, the tendency of the development in Japan and foreign countries, the introduction of CAES in new town districts and the economy are described. (K.I.)

  2. Irreversible data compression concepts with polynomial fitting in time-order of particle trajectory for visualization of huge particle system

    International Nuclear Information System (INIS)

    Ohtani, H; Ito, A M; Hagita, K; Kato, T; Saitoh, T; Takeda, T

    2013-01-01

    We propose in this paper a data compression scheme for large-scale particle simulations, which has favorable prospects for scientific visualization of particle systems. Our data compression concepts deal with the data of particle orbits obtained by simulation directly and have the following features: (i) Through control over the compression scheme, the difference between the simulation variables and the reconstructed values for the visualization from the compressed data becomes smaller than a given constant. (ii) The particles in the simulation are regarded as independent particles and the time-series data for each particle is compressed with an independent time-step for the particle. (iii) A particle trajectory is approximated by a polynomial function based on the characteristic motion of the particle. It is reconstructed as a continuous curve through interpolation from the values of the function for intermediate values of the sample data. We name this concept ''TOKI (Time-Order Kinetic Irreversible compression)''. In this paper, we present an example of an implementation of a data-compression scheme with the above features. Several application results are shown for plasma and galaxy formation simulation data

  3. Feasibility study of a hybrid wind turbine system – Integration with compressed air energy storage

    International Nuclear Information System (INIS)

    Sun, Hao; Luo, Xing; Wang, Jihong

    2015-01-01

    Highlights: • A new hybrid wind turbine system is proposed and feasibility study if conducted. • A complete mathematical model is developed and implemented in a software environment. • Multi-mode control strategy is investigated to ensure the system work smoothly and efficiently. • A prototype for implementing the proposed mechanism is built and tested as proof of the concept. • The proposed system is proved to be technically feasible with energy efficiency around 50%. - Abstract: Wind has been recognized as one of major realistic clean energy sources for power generation to meet the continuously increased energy demand and to achieve the carbon emission reduction targets. However, the utilisation of wind energy encounters an inevitable challenge resulting from the nature of wind intermittency. To address this, the paper presents the recent research work at Warwick on the feasibility study of a new hybrid system by integrating a wind turbine with compressed air energy storage. A mechanical transmission mechanism is designed and implemented for power integration within the hybrid system. A scroll expander is adopted to serve as an “air-machinery energy converter”, which can transmit additional driving power generalized from the stored compressed air to the turbine shaft for smoothing the wind power fluctuation. A mathematical model for the complete hybrid process is developed and the control strategy is investigated for corresponding cooperative operations. A prototype test rig for implementing the proposed mechanism is built for proof of the concept. From the simulated and experimental studies, the energy conversion efficiency analysis is conducted while the system experiences different operation conditions and modes. It is proved that the proposed hybrid wind turbine system is feasible technically

  4. THE USE OF POROUS CERAMICS FOR EVAPORATIVE AND EVAPORATIVE – VAPOR –COMPRESSION SYSTEMS

    Directory of Open Access Journals (Sweden)

    Cheban D.N.

    2013-04-01

    Full Text Available The use of natural evaporative cooling is one of technical solutions of problem of energy efficiency in air conditioning systems. The use of evaporative cooling in the first combined cooling stage allows reducing the load on the condenser of the cooling machine due to reducing of the condensing temperature. This combination allows the use of this type of system in any climatic conditions, including regions with small water resources. Multi-porous ceramic structure is used in evaporative air coolers and water coolers in this case. The objective of this paper is to show advantages of the using of porous ceramic as a working attachment, and to show advantages of the proposed scheme of compression-evaporation systems in comparison with standard vapor compression systems. Experimental research proved the fact, that in the film mode cooling efficiency of air flow is between EA=0,6÷0,7 and is slightly dependent of water flow. For countries with hot and dry climate where reserves of water are limited, it is recommended to use cyclical regime with EA≈0,65 value, or to use channel regime with a value of EA≈0,55. This leads to considerable energy savings. It has been determined, that combined air conditioning system is completely closed on the consumption of water at the parameters of the outside air equal to tA =32ºC and XA>13g/kg (in system with direct evaporative cooling machine, and tA=32ºC and XA>12g/kg (in system with indirect evaporative cooling machine. With these parameters, the cost of water in evaporative cooling stage can be fully compensated by condensate from the evaporator chiller.

  5. Multi-objective optimization of an underwater compressed air energy storage system using genetic algorithm

    International Nuclear Information System (INIS)

    Cheung, Brian C.; Carriveau, Rupp; Ting, David S.K.

    2014-01-01

    This paper presents the findings from a multi-objective genetic algorithm optimization study on the design parameters of an underwater compressed air energy storage system (UWCAES). A 4 MWh UWCAES system was numerically simulated and its energy, exergy, and exergoeconomics were analysed. Optimal system configurations were determined that maximized the UWCAES system round-trip efficiency and operating profit, and minimized the cost rate of exergy destruction and capital expenditures. The optimal solutions obtained from the multi-objective optimization model formed a Pareto-optimal front, and a single preferred solution was selected using the pseudo-weight vector multi-criteria decision making approach. A sensitivity analysis was performed on interest rates to gauge its impact on preferred system designs. Results showed similar preferred system designs for all interest rates in the studied range. The round-trip efficiency and operating profit of the preferred system designs were approximately 68.5% and $53.5/cycle, respectively. The cost rate of the system increased with interest rates. - Highlights: • UWCAES system configurations were developed using multi-objective optimization. • System was optimized for energy efficiency, exergy, and exergoeconomics • Pareto-optimal solution surfaces were developed at different interest rates. • Similar preferred system configurations were found at all interest rates studied

  6. Experimental study of a DMD based compressive line sensing imaging system in the turbulence environment

    Science.gov (United States)

    Ouyang, Bing; Hou, Weilin; Gong, Cuiling; Caimi, Frank M.; Dalgleish, Fraser R.; Vuorenkoski, Anni K.

    2016-05-01

    The Compressive Line Sensing (CLS) active imaging system has been demonstrated to be effective in scattering mediums, such as turbid coastal water through simulations and test tank experiments. Since turbulence is encountered in many atmospheric and underwater surveillance applications, a new CLS imaging prototype was developed to investigate the effectiveness of the CLS concept in a turbulence environment. Compared with earlier optical bench top prototype, the new system is significantly more robust and compact. A series of experiments were conducted at the Naval Research Lab's optical turbulence test facility with the imaging path subjected to various turbulence intensities. In addition to validating the system design, we obtained some unexpected exciting results - in the strong turbulence environment, the time-averaged measurements using the new CLS imaging prototype improved both SNR and resolution of the reconstructed images. We will discuss the implications of the new findings, the challenges of acquiring data through strong turbulence environment, and future enhancements.

  7. Design of a Lossless Image Compression System for Video Capsule Endoscopy and Its Performance in In-Vivo Trials

    Science.gov (United States)

    Khan, Tareq H.; Wahid, Khan A.

    2014-01-01

    In this paper, a new low complexity and lossless image compression system for capsule endoscopy (CE) is presented. The compressor consists of a low-cost YEF color space converter and variable-length predictive with a combination of Golomb-Rice and unary encoding. All these components have been heavily optimized for low-power and low-cost and lossless in nature. As a result, the entire compression system does not incur any loss of image information. Unlike transform based algorithms, the compressor can be interfaced with commercial image sensors which send pixel data in raster-scan fashion that eliminates the need of having large buffer memory. The compression algorithm is capable to work with white light imaging (WLI) and narrow band imaging (NBI) with average compression ratio of 78% and 84% respectively. Finally, a complete capsule endoscopy system is developed on a single, low-power, 65-nm field programmable gate arrays (FPGA) chip. The prototype is developed using circular PCBs having a diameter of 16 mm. Several in-vivo and ex-vivo trials using pig's intestine have been conducted using the prototype to validate the performance of the proposed lossless compression algorithm. The results show that, compared with all other existing works, the proposed algorithm offers a solution to wireless capsule endoscopy with lossless and yet acceptable level of compression. PMID:25375753

  8. The Study of the Frequency Effect of Dynamic Compressive Loading on Primary Articular Chondrocyte Functions Using a Microcell Culture System

    Directory of Open Access Journals (Sweden)

    Wan-Ying Lin

    2014-01-01

    Full Text Available Compressive stimulation can modulate articular chondrocyte functions. Nevertheless, the relevant studies are not comprehensive. This is primarily due to the lack of cell culture apparatuses capable of conducting the experiments in a high throughput, precise, and cost-effective manner. To address the issue, we demonstrated the use of a perfusion microcell culture system to investigate the stimulating frequency (0.5, 1.0, and 2.0 Hz effect of compressive loading (20% and 40% strain on the functions of articular chondrocytes. The system mainly integrates the functions of continuous culture medium perfusion and the generation of pneumatically-driven compressive stimulation in a high-throughput micro cell culture system. Results showed that the compressive stimulations explored did not have a significant impact on chondrocyte viability and proliferation. However, the metabolic activity of chondrocytes was significantly affected by the stimulating frequency at the higher compressive strain of 40% (2 Hz, 40% strain. Under the two compressive strains studied, the glycosaminoglycans (GAGs synthesis was upregulated when the stimulating frequency was set at 1 Hz and 2 Hz. However, the stimulating frequencies explored had no influence on the collagen production. The results of this study provide useful fundamental insights that will be helpful for cartilage tissue engineering and cartilage rehabilitation.

  9. Convolutional neural network-based classification system design with compressed wireless sensor network images.

    Science.gov (United States)

    Ahn, Jungmo; Park, JaeYeon; Park, Donghwan; Paek, Jeongyeup; Ko, JeongGil

    2018-01-01

    With the introduction of various advanced deep learning algorithms, initiatives for image classification systems have transitioned over from traditional machine learning algorithms (e.g., SVM) to Convolutional Neural Networks (CNNs) using deep learning software tools. A prerequisite in applying CNN to real world applications is a system that collects meaningful and useful data. For such purposes, Wireless Image Sensor Networks (WISNs), that are capable of monitoring natural environment phenomena using tiny and low-power cameras on resource-limited embedded devices, can be considered as an effective means of data collection. However, with limited battery resources, sending high-resolution raw images to the backend server is a burdensome task that has direct impact on network lifetime. To address this problem, we propose an energy-efficient pre- and post- processing mechanism using image resizing and color quantization that can significantly reduce the amount of data transferred while maintaining the classification accuracy in the CNN at the backend server. We show that, if well designed, an image in its highly compressed form can be well-classified with a CNN model trained in advance using adequately compressed data. Our evaluation using a real image dataset shows that an embedded device can reduce the amount of transmitted data by ∼71% while maintaining a classification accuracy of ∼98%. Under the same conditions, this process naturally reduces energy consumption by ∼71% compared to a WISN that sends the original uncompressed images.

  10. Photo-acoustic sensor for detection of oil contamination in compressed air systems.

    Science.gov (United States)

    Lassen, Mikael; Harder, David Baslev; Brusch, Anders; Nielsen, Ole Stender; Heikens, Dita; Persijn, Stefan; Petersen, Jan C

    2017-02-06

    We demonstrate an online (in-situ) sensor for continuous detection of oil contamination in compressed air systems complying with the ISO-8573 standard. The sensor is based on the photo-acoustic (PA) effect. The online and real-time PA sensor system has the potential to benefit a wide range of users that require high purity compressed air. Among these are hospitals, pharmaceutical industries, electronics manufacturers, and clean room facilities. The sensor was tested for sensitivity, repeatability, robustness to molecular cross-interference, and stability of calibration. Explicit measurements of hexane (C6H14) and decane (C10H22) vapors via excitation of molecular C-H vibrations at approx. 2950 cm-1 (3.38 μm) were conducted with a custom made interband cascade laser (ICL). For the decane measurements a (1 σ) standard deviation (STD) of 0.3 ppb was demonstrated, which corresponds to a normalized noise equivalent absorption (NNEA) coefficient for the prototype PA sensor of 2.8×10-9 W cm-1 Hz1/2.

  11. Thermodynamic study of multi-effect thermal vapour-compression desalination systems

    International Nuclear Information System (INIS)

    Samaké, Oumar; Galanis, Nicolas; Sorin, Mikhail

    2014-01-01

    The parametric analysis of a multi-effect-evaporation (MEE) desalination system combined with a thermal-vapour-compression (TVC) process activated by a gaseous stream of specified flowrate and temperature was performed based on the principles of classical (1st and 2nd laws) and finite-size thermodynamics. The MEE subsystem was treated as a black box and therefore the results are valid for any combination of physical characteristics and internal operational conditions of this subsystem. They show the effects of four design variables (the motive fluid pressure and the compression ratio of the ejector, the condenser temperature pinch and the ratio of rejected to supplied seawater) on significant operating quantities and performance indicators such as: energy supplied by the heat source; motive fluid flowrate; flowrates of the supplied seawater and produced potable water; specific heat consumption; thermal conductance of the vapour generator and the condenser; exergy destruction by the MEE, the ejector and the vapour generator. Based on the obtained results recommendations are formulated for the optimal choice of values for the four design variables. - Highlights: • Model of a MEE-TVC desalination system independent of MEE characteristics. • Parametric study based on classical (1st and 2nd law) and finite-size thermodynamics. • Effect of 4 design parameters on operating conditions and performance indicators. • Recommended values for the design parameters

  12. Experimental investigation of integrated refrigeration system (IRS) with gas engine, compression chiller and absorption chiller

    International Nuclear Information System (INIS)

    Sun, Z.G.

    2008-01-01

    An integrated refrigeration system (IRS) with a gas engine, a vapor-compression chiller and an absorption chiller is set up and tested. The vapor-compression refrigeration cycle is operated directly by the gas engine. The waste heat from the gas engine operates the absorption refrigeration cycle, which provides additional cooling. The performance of the IRS is described. The cooling capacity of the IRS is about 596 kW, and primary energy ratio (PER) reaches 1.84 at air-conditioning rated conditions. The refrigerating capacity of the prototype increased and PER of prototype decreased with the increase of the gas engine speed. The gas engine speed was preferably regulated at part load condition in order to operate the prototype at high-energy efficiency. The refrigerating capacity and PER of the prototype increased with the increase of the outlet temperature of chilled water or the decrease of the inlet temperature of cooling water. The integrated refrigeration chiller in this work saves running costs as compared to the conventional refrigeration system by using the waste heat

  13. Thermo-Economic Comparison and Parametric Optimizations among Two Compressed Air Energy Storage System Based on Kalina Cycle and ORC

    Directory of Open Access Journals (Sweden)

    Ruixiong Li

    2016-12-01

    Full Text Available The compressed air energy storage (CAES system, considered as one method for peaking shaving and load-levelling of the electricity system, has excellent characteristics of energy storage and utilization. However, due to the waste heat existing in compressed air during the charge stage and exhaust gas during the discharge stage, the efficient operation of the conventional CAES system has been greatly restricted. The Kalina cycle (KC and organic Rankine cycle (ORC have been proven to be two worthwhile technologies to fulfill the different residual heat recovery for energy systems. To capture and reuse the waste heat from the CAES system, two systems (the CAES system combined with KC and ORC, respectively are proposed in this paper. The sensitivity analysis shows the effect of the compression ratio and the temperature of the exhaust on the system performance: the KC-CAES system can achieve more efficient operation than the ORC-CAES system under the same temperature of exhaust gas; meanwhile, the larger compression ratio can lead to the higher efficiency for the KC-CAES system than that of ORC-CAES with the constant temperature of the exhaust gas. In addition, the evolutionary multi-objective algorithm is conducted between the thermodynamic and economic performances to find the optimal parameters of the two systems. The optimum results indicate that the solutions with an exergy efficiency of around 59.74% and 53.56% are promising for KC-CAES and ORC-CAES system practical designs, respectively.

  14. Technical and economic assessment of fluidized bed augmented compressed air energy storage system. Volume III. Preconceptual design

    Energy Technology Data Exchange (ETDEWEB)

    Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

    1981-09-01

    A technical and economic assessment of fluidized bed combustion augmented compressed air energy storage systems is presented. The results of this assessment effort are presented in three volumes. Volume III - Preconceptual Design contains the system analysis which led to the identification of a preferred component configuration for a fluidized bed combustion augmented compressed air energy storage system, the results of the effort which transformed the preferred configuration into preconceptual power plant design, and an introductory evaluation of the performance of the power plant system during part-load operation and while load following.

  15. Influence of special attributes of zeotropic refrigerant mixtures on design and operation of vapour compression refrigeration and heat pump systems

    International Nuclear Information System (INIS)

    Rajapaksha, Leelananda

    2007-01-01

    The use of zeotropic refrigerant mixtures introduces a number of novel issues that affect the established design and operational practices of vapour compression systems used in refrigeration, air conditioning and heat pump applications. Two attributes; composition shift and temperature glide, associated with the phase changing process of zeotropic mixtures are the primary phenomena that bring in these issues. However, relevant researches are uncovering ways how careful system designs and selection of operational parameters allow improving the energy efficiency and the capacity of vapour compression refrigeration systems. Most of these concepts exploit the presence of composition shift and temperature glide. This paper qualitatively discusses how the mixture attributes influence the established heat exchanger design practices, performance and operation of conventional vapour compression systems. How the temperature glide and composition shift can be incorporated to improve the system performance and the efficiency are also discussed

  16. An optimized compression algorithm for real-time ECG data transmission in wireless network of medical information systems.

    Science.gov (United States)

    Cho, Gyoun-Yon; Lee, Seo-Joon; Lee, Tae-Ro

    2015-01-01

    Recent medical information systems are striving towards real-time monitoring models to care patients anytime and anywhere through ECG signals. However, there are several limitations such as data distortion and limited bandwidth in wireless communications. In order to overcome such limitations, this research focuses on compression. Few researches have been made to develop a specialized compression algorithm for ECG data transmission in real-time monitoring wireless network. Not only that, recent researches' algorithm is not appropriate for ECG signals. Therefore this paper presents a more developed algorithm EDLZW for efficient ECG data transmission. Results actually showed that the EDLZW compression ratio was 8.66, which was a performance that was 4 times better than any other recent compression method widely used today.

  17. Depopulation of Caged Layer Hens with a Compressed Air Foam System

    Science.gov (United States)

    Gurung, Shailesh; Hoffman, John; Stringfellow, Kendre; Abi-Ghanem, Daad; Zhao, Dan; Caldwell, David; Lee, Jason; Styles, Darrel; Berghman, Luc; Byrd, James; Farnell, Yuhua; Archer, Gregory

    2018-01-01

    Simple Summary Reportable diseases, such as avian influenza, spread rapidly among poultry, resulting in the death of a large number of birds. Once such a disease has been diagnosed at a farm, infected and susceptible birds are rapidly killed to prevent the spread of the disease. The methods to eliminate infected caged laying hens are limited. An experiment was conducted to study the effectiveness of foam made from compressed air, water, and soap to kill laying hens in cages. The study found that stress levels of the hens killed using compressed air foam in cages to be similar to the hens killed by carbon dioxide or the negative control. Hens exposed to carbon dioxide died earlier as compared to the foam methods. The authors conclude that application of compressed air foam in cages is an alternative to methods such as gas inhalation and ventilation shutdown to rapidly and humanely kill laying hens during epidemics. Abstract During the 2014–2015 US highly pathogenic avian influenza (HPAI) outbreak, 50.4 million commercial layers and turkeys were affected, resulting in economic losses of $3.3 billion. Rapid depopulation of infected poultry is vital to contain and eradicate reportable diseases like HPAI. The hypothesis of the experiment was that a compressed air foam (CAF) system may be used as an alternative to carbon dioxide (CO2) inhalation for depopulating caged layer hens. The objective of this study was to evaluate corticosterone (CORT) and time to cessation of movement (COM) of hens subjected to CAF, CO2 inhalation, and negative control (NEG) treatments. In Experiment 1, two independent trials were conducted using young and spent hens. Experiment 1 consisted of five treatments: NEG, CO2 added to a chamber, a CO2 pre-charged chamber, CAF in cages, and CAF in a chamber. In Experiment 2, only spent hens were randomly assigned to three treatments: CAF in cages, CO2 added to a chamber, and aspirated foam. Serum CORT levels of young hens were not significantly

  18. Upgrade of the SLAC SLED II Pulse Compression System Based on Recent High Power Tests

    International Nuclear Information System (INIS)

    Vlieks, A.E.; Fowkes, W.R.; Loewen, R.J.; Tantawi, S.G.

    2011-01-01

    In the Next Linear Collider (NLC) it is expected that the high power rf components be able to handle peak power levels in excess of 400 MW. We present recent results of high power tests designed to investigate the RF breakdown limits of the X-band pulse compression system used at SLAC. (SLED-II). Results of these tests show that both the TE 01 -TE 10 mode converter and the 4-port hybrid have a maximum useful power limit of 220-250 MW. Based on these tests, modifications of these components have been undertaken to improve their peak field handling capability. Results of these modifications will be presented. As part of an international effort to develop a new 0.5-1.5 TeV electron-positron linear collider for the 21st century, SLAC has been working towards a design, referred to as 'The Next Linear Collider' (NLC), which will operate at 11.424 GHz and utilize 50-75 MW klystrons as rf power sources. One of the major challenges in this design, or any other design, is how to generate and efficiently transport extremely high rf power from a source to an accelerator structure. SLAC has been investigating various methods of 'pulse compressing' a relatively wide rf pulse ((ge) 1 μs) from a klystron into a narrower, but more intense, pulse. Currently a SLED-II pulse compression scheme is being used at SLAC in the NLC Test Accelerator (NLCTA) and in the Accelerator Structures Test Area (ASTA) to provide high rf power for accelerator and component testing. In ASTA, a 1.05 μs pulse from a 50 MW klystron was successfully pulse compressed to 205 MW with a pulse width of 150 ns. Since operation in NLC will require generating and transporting rf power in excess of 400 MW it was decided to test the breakdown limits of the SLED-II rf components in ASTA with rf power up to the maximum available of 400 MW. This required the combining of power from two 50 MW klystrons and feeding the summed power into the SLED-II pulse compressor. Results from this experiment demonstrated that two of

  19. Speech Compression

    Directory of Open Access Journals (Sweden)

    Jerry D. Gibson

    2016-06-01

    Full Text Available Speech compression is a key technology underlying digital cellular communications, VoIP, voicemail, and voice response systems. We trace the evolution of speech coding based on the linear prediction model, highlight the key milestones in speech coding, and outline the structures of the most important speech coding standards. Current challenges, future research directions, fundamental limits on performance, and the critical open problem of speech coding for emergency first responders are all discussed.

  20. Exergy analysis of an adiabatic compressed air energy storage system using a cascade of phase change materials

    International Nuclear Information System (INIS)

    Tessier, Michael J.; Floros, Michael C.; Bouzidi, Laziz; Narine, Suresh S.

    2016-01-01

    Adiabatic compressed air energy storage is an emerging energy storage technology with excellent power and storage capacities. Currently, efficiencies are approximately 70%, in part due to the issue of heat loss during the compression stage. An exergy analysis is presented on a novel adiabatic compressed air energy storage system design utilizing a cascade of PCMs (phase change materials) for waste heat storage and recovery. The melting temperatures and enthalpies of the PCMs were optimized for this system and were shown to be dependent on the number of PCMs, the number of compression stages, and the maximum compression ratio. Efficiencies of storage and recovery using this approach are predicted to be as high as 85%, a 15% increase over current designs which do not incorporate PCMs. - Highlights: • A compressed air energy storage plant using phase change materials is proposed. • Increasing number of phase change materials increases roundtrip exergy efficiency. • A thermodynamic model allows melting points and latent heats required to be predicted.

  1. Evolution of the Orszag-Tang vortex system in a compressible medium. I - Initial average subsonic flow

    Science.gov (United States)

    Dahlburg, R. B.; Picone, J. M.

    1989-01-01

    The results of fully compressible, Fourier collocation, numerical simulations of the Orszag-Tang vortex system are presented. The initial conditions for this system consist of a nonrandom, periodic field in which the magnetic and velocity field contain X points but differ in modal structure along one spatial direction. The velocity field is initially solenoidal, with the total initial pressure field consisting of the superposition of the appropriate incompressible pressure distribution upon a flat pressure field corresponding to the initial, average Mach number of the flow. In these numerical simulations, this initial Mach number is varied from 0.2-0.6. These values correspond to average plasma beta values ranging from 30.0 to 3.3, respectively. It is found that compressible effects develop within one or two Alfven transit times, as manifested in the spectra of compressible quantities such as the mass density and the nonsolenoidal flow field. These effects include (1) a retardation of growth of correlation between the magnetic field and the velocity field, (2) the emergence of compressible small-scale structure such as massive jets, and (3) bifurcation of eddies in the compressible flow field. Differences between the incompressible and compressible results tend to increase with increasing initial average Mach number.

  2. On Active Surge Control of Compression Systems via Characteristic Linearization and Model Nonlinearity Cancellation

    Directory of Open Access Journals (Sweden)

    Yohannes S.M. Simamora

    2014-09-01

    Full Text Available A simple approach of active surge control of compression systems is presented. Specifically, nonlinear components of the pressure ratio and rotating speed states of the Moore-Greitzer model are transferred into the input vectors. Subsequently, the compressor characteristic is linearized into two modes, which describe the stable region and the unstable region respectively. As a result, the system’s state and input matrices both appear linear, to which linear realization and analysis are applicable. A linear quadratic regulator plus integrator is then chosen as closed-loop controller. By simulation it was shown that the modified model and characteristics can describe surge behavior, while the closed-loop controller can stabilize the system in the unstable operating region. The last-mentioned was achieved when massflow was 5.38 per cent less than the surge point.

  3. Commissioning and operational results of the 12 GeV helium compression system at Jlab

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, Peter N. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Ganni, Venkatarao [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Dixon, Kelly D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Norton, Robert O. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Creel, Jonathan D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2015-12-01

    The new compressor system at Jefferson Lab (JLab) for the 12 GeV upgrade was commissioned in the spring of 2013 and incorporates many design changes, discussed in previous publications, to improve the operational range, efficiency, reliability and maintainability as compared to previous compressor skids used for this application. The 12 GeV helium compression system has five compressors configured with four pressure levels supporting three pressure levels in the new cold box. During compressor commissioning the compressors were operated independent of the cold box over a wide range of process conditions to verify proper performance including adequate cooling and oil removal. Isothermal and volumetric efficiencies over these process conditions for several built-involume ratios were obtained. This paper will discuss the operational envelope results and the modifications/improvements incorporated into the skids.

  4. Energy-efficiency-oriented cascade control for vapor compression refrigeration cycle systems

    International Nuclear Information System (INIS)

    Yin, Xiaohong; Wang, Xinli; Li, Shaoyuan; Cai, Wenjian

    2016-01-01

    The vapor compression refrigeration cycle (VCC) system plays an important role and accounts for a large proportion of energy consumption from the heating, ventilating, and air-conditioning (HVAC) system. The traditional control approaches, for example PID control method, however, cannot meet the cooling demands with the satisfactory energy efficiency as well. This paper presents a novel energy-efficiency-oriented cascade control strategy for the VCC systems to improve the energy efficiency and fulfill the cooling requirements of indoor occupants simultaneously. In outer loop, a mathematic model is developed to determine the set point of superheat by a PI controller based on the nonlinear correlation between cooling demands and superheat degree. In inner loop, the pressure difference and superheat degree of evaporator are controlled by a model predictive control (MPC) strategy to track the values which are determined in the outer loop, simultaneously to enhance system efficiency of the VCC systems. Simulation and experiments studies are carried out to show the effectiveness of this proposed cascade control strategy and the results indicate significant tracking performance and energy efficiency improvements on VCC system. Compared to other schemes, the proposed cascade control strategy can improve energy efficiency by up to 5.8%. - Highlights: • Energy-efficiency-oriented cascade control strategy for VCC system is presented. • The correlation between cooling requirements and superheat is analyzed. • A MPC-based controller is developed to maximize system energy efficiency. • Experimental results confirm the effectiveness of the proposed control strategy.

  5. Performance study on a low-temperature absorption–compression cascade refrigeration system driven by low-grade heat

    International Nuclear Information System (INIS)

    Xu, Yingjie; Chen, Guangming; Wang, Qin; Han, Xiaohong; Jiang, Ning; Deng, Shiming

    2016-01-01

    Highlights: • An absorption–compression system for low-temperature is developed and analyzed. • Cooling capacity, compression power, and discharge temperature are all improved. • At −170 °C, giving 200 W low-grade cooling capacity, COP increases by 28.6%. • Simulation results are verified experimentally, showing good agreement. - Abstract: This paper presents a performance study on a low-temperature absorption–compression cascade refrigeration system (LACRS), which consists of an absorption subsystem (AS) and a vapor compression auto-cascade subsystem (CS). In the system, low-grade heat of AS is used to subcool the CS, which can obtain cold energy at −170 °C. A simulation study is carried out to investigate the effects of evaporating temperature and low-grade cooling capacity on system performance. The study results show that as low-grade cooling capacity from the AS is provided to the CS, high-grade cooling capacity increases, compressor power consumption decreases, and the COP of the CS therefore increases. Comparing with compression auto-cascade cycle, the largest COP improvement of LACRS is about 38%. The model is verified by experimental data. An additional high-grade cooling capacity is obtained experimentally at −170 °C. The study results presented in this paper not only demonstrate the excellent performance of the LACRS, but also provide important guidance to further system design, and practical application.

  6. Compressive Sensing Based Bayesian Sparse Channel Estimation for OFDM Communication Systems: High Performance and Low Complexity

    Science.gov (United States)

    Xu, Li; Shan, Lin; Adachi, Fumiyuki

    2014-01-01

    In orthogonal frequency division modulation (OFDM) communication systems, channel state information (CSI) is required at receiver due to the fact that frequency-selective fading channel leads to disgusting intersymbol interference (ISI) over data transmission. Broadband channel model is often described by very few dominant channel taps and they can be probed by compressive sensing based sparse channel estimation (SCE) methods, for example, orthogonal matching pursuit algorithm, which can take the advantage of sparse structure effectively in the channel as for prior information. However, these developed methods are vulnerable to both noise interference and column coherence of training signal matrix. In other words, the primary objective of these conventional methods is to catch the dominant channel taps without a report of posterior channel uncertainty. To improve the estimation performance, we proposed a compressive sensing based Bayesian sparse channel estimation (BSCE) method which cannot only exploit the channel sparsity but also mitigate the unexpected channel uncertainty without scarifying any computational complexity. The proposed method can reveal potential ambiguity among multiple channel estimators that are ambiguous due to observation noise or correlation interference among columns in the training matrix. Computer simulations show that proposed method can improve the estimation performance when comparing with conventional SCE methods. PMID:24983012

  7. Triaxial Compression Testing of Multicomponent Geomaterials from Quartz-Poor (Syenitic Systems

    Directory of Open Access Journals (Sweden)

    Krmíček Lukáš

    2017-12-01

    Full Text Available This paper focuses on mafic microgranular enclaves enclosed in quartz-poor igneous rocks and their effect on strength properties of the rock massif. The study examines host rock–enclave multicomponent geomaterials from enclave-bearing syenitic rocks from the Třebíč Massif exposed in the Královec quarry near Jaroměřice nad Rokytnou in the Czech Republic. A series of laboratory tests were performed to describe strength properties of individual constituents of the multicomponent geomaterials. We mainly focused on triaxial compression tests, however, rebound hardness, uniaxial compressive strength and indirect tensile strength were determined as well. The obtained results indicate that enclaves and even the contact zones between the enclaves and host rocks do not have any negative influence on the rock strength. In contrast, enclaves represent “stress concentrators” within such multicomponent systems. Strength properties of various multicomponent geomaterials are practically an unexplored topic in the field of rocks mechanics and future studies are needed to establish a robust database describing the behaviour of such geocomposites.

  8. Self-compression of spatially limited laser pulses in a system of coupled light-guides

    Science.gov (United States)

    Balakin, A. A.; Litvak, A. G.; Mironov, V. A.; Skobelev, S. A.

    2018-04-01

    The self-action features of wave packets propagating in a 2D system of equidistantly arranged fibers are studied analytically and numerically on the basis of the discrete nonlinear Schrödinger equation. Self-consistent equations for the characteristic scales of a Gaussian wave packet are derived on the basis of the variational approach, which are proved numerically for powers P beams become filamented, and their amplitude is limited due to the nonlinear breaking of the interaction between neighboring light-guides. This makes it impossible to collect a powerful wave beam in a single light-guide. Variational analysis shows the possibility of the adiabatic self-compression of soliton-like laser pulses in the process of 3D self-focusing on the central light-guide. However, further increase of the field amplitude during self-compression leads to the development of longitudinal modulation instability and the formation of a set of light bullets in the central fiber. In the regime of hollow wave beams, filamentation instability becomes predominant. As a result, it becomes possible to form a set of light bullets in optical fibers located on the ring.

  9. Performance characterization of compressed sensing positron emission tomography detectors and data acquisition system

    Science.gov (United States)

    Chang, Chen-Ming; Grant, Alexander M.; Lee, Brian J.; Kim, Ealgoo; Hong, KeyJo; Levin, Craig S.

    2015-08-01

    In the field of information theory, compressed sensing (CS) had been developed to recover signals at a lower sampling rate than suggested by the Nyquist-Shannon theorem, provided the signals have a sparse representation with respect to some base. CS has recently emerged as a method to multiplex PET detector readouts thanks to the sparse nature of 511 keV photon interactions in a typical PET study. We have shown in our previous numerical studies that, at the same multiplexing ratio, CS achieves higher signal-to-noise ratio (SNR) compared to Anger and cross-strip multiplexing. In addition, unlike Anger logic, multiplexing by CS preserves the capability to resolve multi-hit events, in which multiple pixels are triggered within the resolving time of the detector. In this work, we characterized the time, energy and intrinsic spatial resolution of two CS detectors and a data acquisition system we have developed for a PET insert system for simultaneous PET/MRI. The CS detector comprises a 2× 4 mosaic of 4× 4 arrays of 3.2× 3.2× 20 mm3 lutetium-yttrium orthosilicate crystals coupled one-to-one to eight 4× 4 silicon photomultiplier arrays. The total number of 128 pixels is multiplexed down to 16 readout channels by CS. The energy, coincidence time and intrinsic spatial resolution achieved by two CS detectors were 15.4+/- 0.1 % FWHM at 511 keV, 4.5 ns FWHM and 2.3 mm FWHM, respectively. A series of experiments were conducted to measure the sources of time jitter that limit the time resolution of the current system, which provides guidance for potential system design improvements. These findings demonstrate the feasibility of compressed sensing as a promising multiplexing method for PET detectors.

  10. The Influence of Video Game Training with and without Subpatelar Bandage in Mobility and Gait Speed on Elderly Female Fallers

    Directory of Open Access Journals (Sweden)

    Isabela Feitosa de Carvalho

    2018-01-01

    Full Text Available Objectives. The aim of the study was to investigate the effect of balance training with Nintendo Wii technology, with and without the use of additional sensory information (subpatellar bandage, in the functional mobility and gait speed of elderly female fallers. Methods. Twenty elderly women were divided into two groups: group I: trained with the use of the Nintendo Wii; group II: trained using the Nintendo Wii and the addition of sensory information (subpatellar bandage. The functional mobility was assessed with the Timed up and Go test (TUG and gait speed with the 10 m test. The tests were carried out with and without the use of the subpatellar bandage. The training was carried out within sessions of 30 minutes, twice a week, using three different games (Penguin Slide, Table Tilt, and Tightrope. Results. There was an increase in the gait speed and a decrease in the TUG time in both groups, independently of the sensory condition used (p<0.05. In the short term, the subpatellar bandage improved the TUG time (p<0.05 and the gait speed (p<0.01. Conclusion. The training for postural balance with virtual reality was effective for improving functional mobility and gait speed of elderly female fallers. The subpatellar bandage did not maximize the effect of training.

  11. The Influence of Video Game Training with and without Subpatelar Bandage in Mobility and Gait Speed on Elderly Female Fallers.

    Science.gov (United States)

    de Carvalho, Isabela Feitosa; Leme, Gianluca Loyolla Montanari; Scheicher, Marcos Eduardo

    2018-01-01

    The aim of the study was to investigate the effect of balance training with Nintendo Wii technology, with and without the use of additional sensory information (subpatellar bandage), in the functional mobility and gait speed of elderly female fallers. Twenty elderly women were divided into two groups: group I: trained with the use of the Nintendo Wii; group II: trained using the Nintendo Wii and the addition of sensory information (subpatellar bandage). The functional mobility was assessed with the Timed up and Go test (TUG) and gait speed with the 10 m test. The tests were carried out with and without the use of the subpatellar bandage. The training was carried out within sessions of 30 minutes, twice a week, using three different games ( Penguin Slide , Table Tilt , and Tightrope ). There was an increase in the gait speed and a decrease in the TUG time in both groups, independently of the sensory condition used ( p < 0.05). In the short term, the subpatellar bandage improved the TUG time ( p < 0.05) and the gait speed ( p < 0.01). The training for postural balance with virtual reality was effective for improving functional mobility and gait speed of elderly female fallers. The subpatellar bandage did not maximize the effect of training.

  12. Cyclops: single-pixel imaging lidar system based on compressive sensing

    Science.gov (United States)

    Magalhães, F.; Correia, M. V.; Farahi, F.; Pereira do Carmo, J.; Araújo, F. M.

    2017-11-01

    Mars and the Moon are envisaged as major destinations of future space exploration missions in the upcoming decades. Imaging LIDARs are seen as a key enabling technology in the support of autonomous guidance, navigation and control operations, as they can provide very accurate, wide range, high-resolution distance measurements as required for the exploration missions. Imaging LIDARs can be used at critical stages of these exploration missions, such as descent and selection of safe landing sites, rendezvous and docking manoeuvres, or robotic surface navigation and exploration. Despite these devices have been commercially available and used for long in diverse metrology and ranging applications, their size, mass and power consumption are still far from being suitable and attractive for space exploratory missions. Here, we describe a compact Single-Pixel Imaging LIDAR System that is based on a compressive sensing technique. The application of the compressive codes to a DMD array enables compression of the spatial information, while the collection of timing histograms correlated to the pulsed laser source ensures image reconstruction at the ranged distances. Single-pixel cameras have been compared with raster scanning and array based counterparts in terms of noise performance, and proved to be superior. Since a single photodetector is used, a better SNR and higher reliability is expected in contrast with systems using large format photodetector arrays. Furthermore, the event of failure of one or more micromirror elements in the DMD does not prevent full reconstruction of the images. This brings additional robustness to the proposed 3D imaging LIDAR. The prototype that was implemented has three modes of operation. Range Finder: outputs the average distance between the system and the area of the target under illumination; Attitude Meter: provides the slope of the target surface based on distance measurements in three areas of the target; 3D Imager: produces 3D ranged

  13. Wireless EEG System Achieving High Throughput and Reduced Energy Consumption Through Lossless and Near-Lossless Compression.

    Science.gov (United States)

    Alvarez, Guillermo Dufort Y; Favaro, Federico; Lecumberry, Federico; Martin, Alvaro; Oliver, Juan P; Oreggioni, Julian; Ramirez, Ignacio; Seroussi, Gadiel; Steinfeld, Leonardo

    2018-02-01

    This work presents a wireless multichannel electroencephalogram (EEG) recording system featuring lossless and near-lossless compression of the digitized EEG signal. Two novel, low-complexity, efficient compression algorithms were developed and tested in a low-power platform. The algorithms were tested on six public EEG databases comparing favorably with the best compression rates reported up to date in the literature. In its lossless mode, the platform is capable of encoding and transmitting 59-channel EEG signals, sampled at 500 Hz and 16 bits per sample, at a current consumption of 337 A per channel; this comes with a guarantee that the decompressed signal is identical to the sampled one. The near-lossless mode allows for significant energy savings and/or higher throughputs in exchange for a small guaranteed maximum per-sample distortion in the recovered signal. Finally, we address the tradeoff between computation cost and transmission savings by evaluating three alternatives: sending raw data, or encoding with one of two compression algorithms that differ in complexity and compression performance. We observe that the higher the throughput (number of channels and sampling rate) the larger the benefits obtained from compression.

  14. Modelling and analysis of a novel compressed air energy storage system for trigeneration based on electrical energy peak load shifting

    International Nuclear Information System (INIS)

    Lv, Song; He, Wei; Zhang, Aifeng; Li, Guiqiang; Luo, Bingqing; Liu, Xianghua

    2017-01-01

    Highlights: • A new CAES system for trigeneration based on electrical peak load shifting is proposed. • The theoretical models and the thermodynamics process are established and analyzed. • The relevant parameters influencing its performance have been discussed and optimized. • A novel energy and economic evaluation methods is proposed to evaluate the performance of the system. - Abstract: The compressed air energy storage (CAES) has made great contribution to both electricity and renewable energy. In the pursuit of reduced energy consumption and relieving power utility pressure effectively, a novel trigeneration system based on CAES for cooling, heating and electricity generation by electrical energy peak load shifting is proposed in this paper. The cooling power is generated by the direct expansion of compressed air, and the heating power is recovered in the process of compression and storage. Based on the working principle of the typical CAES, the theoretical analysis of the thermodynamic system models are established and the characteristics of the system are analyzed. A novel method used to evaluate energy and economic performance is proposed. A case study is conducted, and the economic-social and technical feasibility of the proposed system are discussed. The results show that the trigeneration system works efficiently at relatively low pressure, and the efficiency is expected to reach about 76.3% when air is compressed and released by 15 bar. The annual monetary cost saving annually is about 53.9%. Moreover, general considerations about the proposed system are also presented.

  15. Theoretical evaluation on the impact of heat exchanger in Advanced Adiabatic Compressed Air Energy Storage system

    International Nuclear Information System (INIS)

    Yang, Ke; Zhang, Yuan; Li, Xuemei; Xu, Jianzhong

    2014-01-01

    Highlights: • A multi-stage AA-CAES system model is established based on thermodynamic theory. • Four Cases about pressure loss and effectiveness of heat exchanger are investigated. • The impact of pressure loss on conversion of heat energy in TES is more sensitive. • The impact of heat exchanger effectiveness in charge process on system is stronger. • Pressure loss in heat exchanger affects the change trends of system efficiency. - Abstract: Advanced Adiabatic Compressed Air Energy Storage (AA-CAES) is a large-scale energy storage system based on gas turbine technology and thermal energy storage (TES). Electrical energy can be converted into internal energy of air and heat energy in TES during the charge process, while reverse energy conversion proceeds during discharge process. The performance of AA-CAES system requires further improvement in order to increase efficiency. In this paper, a multi-stage AA-CAES system model is established, and the influence of effectiveness and pressure loss in heat exchanger on energy conversion and utilization efficiency of AA-CAES system is analyzed theoretically based on the theory of thermodynamics. Four Cases about effectiveness and pressure loss of heat exchanger are investigated and compared with each other. It is found that effectiveness and pressure loss of heat exchanger are directly related to energy conversion and utilization in AA-CAES system. System efficiency changes with the variation of heat exchanger effectiveness and the impact of pressure loss on conversion of heat energy in TES is more sensitive than that of internal energy of air. Pressure loss can cause the complexity of system efficiency change. With appropriate selection of the values of heat exchanger effectiveness for both charge and discharge processes, an AA-CAES system with a higher efficiency could be expected

  16. Economic analysis of using above ground gas storage devices for compressed air energy storage system

    Science.gov (United States)

    Liu, Jinchao; Zhang, Xinjing; Xu, Yujie; Chen, Zongyan; Chen, Haisheng; Tan, Chunqing

    2014-12-01

    Above ground gas storage devices for compressed air energy storage (CAES) have three types: air storage tanks, gas cylinders, and gas storage pipelines. A cost model of these gas storage devices is established on the basis of whole life cycle cost (LCC) analysis. The optimum parameters of the three types are determined by calculating the theoretical metallic raw material consumption of these three devices and considering the difficulties in manufacture and the influence of gas storage device number. The LCCs of the three types are comprehensively analyzed and compared. The result reveal that the cost of the gas storage pipeline type is lower than that of the other two types. This study may serve as a reference for designing large-scale CAES systems.

  17. Compressed air demand-type firefighter's breathing system, volume 1. [design analysis and performance tests

    Science.gov (United States)

    Sullivan, J. L.

    1975-01-01

    The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.

  18. A theory of post-stall transients in axial compression systems. I - Development of equations

    Science.gov (United States)

    Moore, F. K.; Greitzer, E. M.

    1985-01-01

    An approximate theory is presented for post-stall transients in multistage axial compression systems. The theory leads to a set of three simultaneous nonlinear third-order partial differential equations for pressure rise, and average and disturbed values of flow coefficient, as functions of time and angle around the compressor. By a Galerkin procedure, angular dependence is averaged, and the equations become first order in time. These final equations are capable of describing the growth and possible decay of a rotating-stall cell during a compressor mass-flow transient. It is shown how rotating-stall-like and surgelike motions are coupled through these equations, and also how the instantaneous compressor pumping characteristic changes during the transient stall process.

  19. Advanced exergy analysis of a R744 booster refrigeration system with parallel compression

    DEFF Research Database (Denmark)

    Gullo, Paride; Elmegaard, Brian; Cortella, Giovanni

    2016-01-01

    In this paper, the advanced exergy analysis was applied to a R744 booster refrigeration system with parallel compression taking into account the design external temperatures of 25 degrees C and 35 degrees C, as well as the operating conditions of a conventional European supermarket. The global...... efficiencies of all the chosen compressors were extrapolated from some manufactures' data and appropriated optimization procedures of the performance of the investigated solution were implemented.According to the results associated with the conventional exergy evaluation, the gas cooler/condenser, the HS (high...... stage) compressor and the MT (medium temperature) display cabinet exhibited the highest enhancement potential. The further splitting of their corresponding exergy destruction rates into their different parts and the following assessment of the interactions among the components allowed figuring out...

  20. Technology assessment report for the Soyland Power Cooperative, Inc. compressed air energy storage system (CAES)

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    The design and operational features of compressed air energy storage systems (CAES) in general and, specifically, of a proposed 220 MW plant being planned by the Soyland Power Cooperative, Inc. in Illinois are described. This technology assessment discusses the need for peaking capacity, CAES requirements for land, fuel, water, and storage caverns, and compares the costs, environmental impacts and licensing requirements of CAES with those of power plants using simple cycle or combined cycle combustion turbines. It is concluded that during the initial two years of CAES operation, the CAES would cost more than a combustion turbine or combined cycle facility, but thereafter the CAES would have a increasing economic advantage; the overall environmental impact of a CAES plant is minimal, and that there should be no great difficulties with CAES licensing. (LCL)

  1. A Near-Lossless Image Compression Algorithm Suitable for Hardware Design in Wireless Endoscopy System

    Directory of Open Access Journals (Sweden)

    Xie Xiang

    2007-01-01

    Full Text Available In order to decrease the communication bandwidth and save the transmitting power in the wireless endoscopy capsule, this paper presents a new near-lossless image compression algorithm based on the Bayer format image suitable for hardware design. This algorithm can provide low average compression rate ( bits/pixel with high image quality (larger than dB for endoscopic images. Especially, it has low complexity hardware overhead (only two line buffers and supports real-time compressing. In addition, the algorithm can provide lossless compression for the region of interest (ROI and high-quality compression for other regions. The ROI can be selected arbitrarily by varying ROI parameters. In addition, the VLSI architecture of this compression algorithm is also given out. Its hardware design has been implemented in m CMOS process.

  2. Multi-objective optimization and exergoeconomic analysis of a combined cooling, heating and power based compressed air energy storage system

    International Nuclear Information System (INIS)

    Yao, Erren; Wang, Huanran; Wang, Ligang; Xi, Guang; Maréchal, François

    2017-01-01

    Highlights: • A novel tri-generation based compressed air energy storage system. • Trade-off between efficiency and cost to highlight the best compromise solution. • Components with largest irreversibility and potential improvements highlighted. - Abstract: Compressed air energy storage technologies can improve the supply capacity and stability of the electricity grid, particularly when fluctuating renewable energies are massively connected. While incorporating the combined cooling, heating and power systems into compressed air energy storage could achieve stable operation as well as efficient energy utilization. In this paper, a novel combined cooling, heating and power based compressed air energy storage system is proposed. The system combines a gas engine, supplemental heat exchangers and an ammonia-water absorption refrigeration system. The design trade-off between the thermodynamic and economic objectives, i.e., the overall exergy efficiency and the total specific cost of product, is investigated by an evolutionary multi-objective algorithm for the proposed combined system. It is found that, with an increase in the exergy efficiency, the total product unit cost is less affected in the beginning, while rises substantially afterwards. The best trade-off solution is selected with an overall exergy efficiency of 53.04% and a total product unit cost of 20.54 cent/kWh, respectively. The variation of decision variables with the exergy efficiency indicates that the compressor, turbine and heat exchanger preheating the inlet air of turbine are the key equipment to cost-effectively pursuit a higher exergy efficiency. It is also revealed by an exergoeconomic analysis that, for the best trade-off solution, the investment costs of the compressor and the two heat exchangers recovering compression heat and heating up compressed air for expansion should be reduced (particularly the latter), while the thermodynamic performance of the gas engine need to be improved

  3. The Development of the Electrically Controlled High Power RF Switch and Its Application to Active RF Pulse Compression Systems

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Jiquan [Stanford Univ., CA (United States)

    2008-12-01

    In the past decades, there has been increasing interest in pulsed high power RF sources for building high-gradient high-energy particle accelerators. Passive RF pulse compression systems have been used in many applications to match the available RF sources to the loads requiring higher RF power but a shorter pulse. Theoretically, an active RF pulse compression system has the advantage of higher efficiency and compactness over the passive system. However, the key component for such a system an element capable of switching hundreds of megawatts of RF power in a short time compared to the compressed pulse width is still an open problem. In this dissertation, we present a switch module composed of an active window based on the bulk effects in semiconductor, a circular waveguide three-port network and a movable short plane, with the capability to adjust the S-parameters before and after switching. The RF properties of the switch module were analyzed. We give the scaling laws of the multiple-element switch systems, which allow the expansion of the system to a higher power level. We present a novel overmoded design for the circular waveguide three-port network and the associated circular-to-rectangular mode-converter. We also detail the design and synthesis process of this novel mode-converter. We demonstrate an electrically controlled ultra-fast high power X-band RF active window built with PIN diodes on high resistivity silicon. The window is capable of handling multi-megawatt RF power and can switch in 2-300ns with a 1000A current driver. A low power active pulse compression experiment was carried out with the switch module and a 375ns resonant delay line, obtaining 8 times compression gain with a compression ratio of 20.

  4. Frontal compression along the Apennines thrust system: The Emilia 2012 example from seismicity to crustal structure

    Science.gov (United States)

    Chiarabba, Claudio; De Gori, Pasquale; Improta, Luigi; Lucente, Francesco Pio; Moretti, Milena; Govoni, Aladino; Di Bona, Massimo; Margheriti, Lucia; Marchetti, Alessandro; Nardi, Anna

    2014-12-01

    The evolution of the Apennines thrust-and-fold belt is related to heterogeneous process of subduction and continental delamination that generates extension within the mountain range and compression on the outer front of the Adria lithosphere. While normal faulting earthquakes diffusely occur along the mountain chain, the sparse and poor seismicity in the compressional front does not permit to resolve the ambiguity that still exists about which structure accommodates the few mm/yr of convergence observed by geodetic data. In this study, we illustrate the 2012 Emilia seismic sequence that is the most significant series of moderate-to-large earthquakes developed during the past decades on the compressional front of the Apennines. Accurately located aftershocks, along with P-wave and Vp/Vs tomographic models, clearly reveal the geometry of the thrust system, buried beneath the Quaternary sediments of the Po Valley. The seismic sequence ruptured two distinct adjacent thrust faults, whose different dip, steep or flat, accounts for the development of the arc-like shape of the compressional front. The first shock of May 20 (Mw 6.0) developed on the middle Ferrara thrust that has a southward dip of about 30°. The second shock of May 29 (Mw 5.8) ruptured the Mirandola thrust that we define as a steep dipping (50-60°) pre-existing (Permo-Triassic) basement normal fault inverted during compression. The overall geometry of the fault system is controlled by heterogeneity of the basement inherited from the older extension. We also observe that the rupture directivity during the two main-shocks and the aftershocks concentration correlate with low Poisson ratio volumes, probably indicating that portions of the fault have experienced intense micro-damage.

  5. Compression stockings for treating venous leg ulcers: measurement of interface pressure under a new ulcer kit.

    Science.gov (United States)

    Partsch, B; Partsch, H

    2008-01-01

    The aim of this study was to measure the interface pressure of a newly designed two-layer compression stocking (Mediven ulcer kit Medi QMBH, Bayreuth, Germany) in different body positions and to compare the values with those obtained with another two-layer product. Interface pressure was measured on the distal medial leg in 16 legs of volunteers, with the basic layer alone and with the whole stocking kit in the supine, sitting and standing position for both stocking systems. The literature concerning ulcer-healing rates is reviewed. Mediven ulcerkit produced statistically significant higher pressure values than the ulcer stocking with a median resting value of 35.5 mmHg in the supine and 42.5 mmHg in the standing position. The pressure while standing comes close to values exerted by bandages. The basic layer alone applies a pressure of 20.5 mmHg. Especially designed compression stockings exerting sufficient interface pressure may be indicated in patients with small ulcers of short duration.

  6. No Cost – Low Cost Compressed Air System Optimization in Industry

    Science.gov (United States)

    Dharma, A.; Budiarsa, N.; Watiniasih, N.; Antara, N. G.

    2018-04-01

    Energy conservation is a systematic, integrated of effort, in order to preserve energy sources and improve energy utilization efficiency. Utilization of energy in efficient manner without reducing the energy usage it must. Energy conservation efforts are applied at all stages of utilization, from utilization of energy resources to final, using efficient technology, and cultivating an energy-efficient lifestyle. The most common way is to promote energy efficiency in the industry on end use and overcome barriers to achieve such efficiency by using system energy optimization programs. The facts show that energy saving efforts in the process usually only focus on replacing tools and not an overall system improvement effort. In this research, a framework of sustainable energy reduction work in companies that have or have not implemented energy management system (EnMS) will be conducted a systematic technical approach in evaluating accurately a compressed-air system and potential optimization through observation, measurement and verification environmental conditions and processes, then processing the physical quantities of systems such as air flow, pressure and electrical power energy at any given time measured using comparative analysis methods in this industry, to provide the potential savings of energy saving is greater than the component approach, with no cost to the lowest cost (no cost - low cost). The process of evaluating energy utilization and energy saving opportunities will provide recommendations for increasing efficiency in the industry and reducing CO2 emissions and improving environmental quality.

  7. Thermal and economical optimization of air conditioning units with vapor compression refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Sanaye, S.; Malekmohammadi, H.R. [Iran University of Science and Technology, Tehran (Iran). Dept. of Mechanical Engineering

    2004-09-01

    A new method of thermal and economical optimum design of air conditioning units with vapor compression refrigeration system, is presented. Such a system includes compressor, condenser, evaporator, centrifugal and axial fans. Evaporator and condenser temperatures, their heating surface areas (frontal surface area and number of tubes), centrifugal and axial fan powers, and compressor power are among the design variables. The data provided by manufacturers for fan (volume flow rate versus pressure drop) and compressor power (using evaporator and condenser temperatures) was used to choose these components directly from available data for consumers. To study the performance of the system under various situations, and implementing the optimization procedure, a simulation program including all thermal and geometrical parameters was developed. The objective function for optimization was the total cost per unit cooling load of the system including capital investment for components as well as the required electricity cost. To find the system design parameters, this objective function was minimized by Lagrange multipliers method. The effects of changing the cooling load on optimal design parameters were studied. (author)

  8. Work plan for upgrading the 241-A-701 compressed air system and motor control center. Revision 1

    International Nuclear Information System (INIS)

    Carpenter, K.E.

    1995-01-01

    This work plan will outline the responsibilities associated with the 241-A-701 Compressed Air System (CAS) and Motor Control Center (MCC) upgrades. All activities required to design, install, test, and operate the modified systems are addressed in this document. Upgrades Technical Support (UTS) of TWRS Engineering is responsible for the completion of all tasks associated with this upgrade. UTS will coordinate the upgrade activities, and ensure all tasks are successfully completed on or before the scheduled dates. The primary objective of the 241-A-701 Compressor and MCC Upgrade is to provide a reliable source of process and instrument compressed air to the A, AX, AY, and AZ tank farms

  9. Comparative Survey of Ultrasound Images Compression Methods Dedicated to a Tele-Echography Robotic System

    National Research Council Canada - National Science Library

    Delgorge, C

    2001-01-01

    .... For the purpose of this work, we selected seven compression methods : Fourier Transform, Discrete Cosine Transform, Wavelets, Quadtrees Transform, Fractals, Histogram Thresholding, and Run Length Coding...

  10. Development of a control system for compression and expansion cycles of critical valve for high vacuum systems

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Jyoti, E-mail: jagarwal@ipr.res.in; Sharma, H.; Patel, Haresh; Gangradey, R.; Lambade, Vrushabh

    2016-11-15

    Highlights: • Control system with feedback loop of pressure gauge is developed for measuring the life cycle of vacuum isolation valve. • GUI based software developed for easy use and handling of control system. • Control system tested with an experiment showcasing the capability of the control system. • Control system can operate valve based on pressure inside the chamber, which helps to know the degradation of sealing capabilities of valve. • Control system can monitor the total closing and opening time of valve, cycles and pressure inside the vessel. - Abstract: A control system with feedback loop is designed, developed and tested to monitor the life cycles of the axial valve and bellows used in vacuum valves. The control system monitors number of compression cycles of any bellow or closing and opening cycle of a valve. It also interfaces vacuum gauges or pressure gauges to get pressure values inside the system. To find life cycle of valve, the developed control and monitoring system is integrated with an axial valve experimental test set up. In this system, feedback from the vacuum gauge attached to valve enclosure, is given and the life cycle test is automated. This paper describes the control and monitoring system in details and briefs the experiment carried out for valve life cycle. The same system can be used for life cycle estimate for bellows. A suitable GUI is also developed to control the function of the components and resister the number of cycles.

  11. Pulse compression system for the ANL 20 MeV linac

    International Nuclear Information System (INIS)

    Mavrogenes, G.; Norem, J.; Simpson, J.

    1986-01-01

    This paper describes the pulse compression system being built on the Argonne 20 MeV electron linac. The system is designed to rotate the bunch from the present measured pulse length of 38 psec FWHM, to pulse lengths of 5 to 6 ps with the large instantaneous currents (1 to 4 kA) possible instantaneous current. This system was necessary to extend the study of reactive fragments of molecules to the time scale of a few picoseconds, in particular to examine the chemistry of electrons and ions before and during relaxation of the surrounding media. These experiments are not sensitive to the beam energy spread, High Energy Physics experiments studying wake fields have also been proposed using the short bunches and the facility was designed so that the wake field experiment could share the beam bunching system. The 20 MeV electron linac uses a double gap, 12th subharmonic prebuncher together with a one wavelength 1.3 Ghz prebuncher to produce a single pulse of 38 ps from one occupied rf bucket. Beam emittances of 15.7 mmmr have been measured for 40 nC of accelerated charge and 8 mmmr at 10 nC. The energy spread of dE/E = 1% (FWHM) has been measured at 40 nC. Thus the accelerated beam has excellent time structure, high current, and good emittance

  12. Metrological and operational performance of measuring systems used in vehicle compressed natural gas filling stations

    Energy Technology Data Exchange (ETDEWEB)

    Velosa, Jhonn F.; Abril, Henry; Garcia, Luis E. [CDT de GAS (Venezuela). Gas Technological Development Center Corporation

    2008-07-01

    Corporation CDT GAS financially supported by the Colombian government through COLCIENCIAS, carried out a study aimed at designing, developing and implementing in Colombia a calibration and metrological verification 'specialized service' for gas meters installed at dispensers of filling stations using compressed natural gas. The results permitted the identification of improving opportunities (in measuring systems, equipment and devices used to deliver natural gas) which are focused on achieving the highest security and reliability of trading processes of CNG for vehicles. In the development of the first stage of the project, metrological type variables were initially considered, but given the importance of the measuring system and its interaction with the various elements involving gas supply to the filling station, the scope of the work done included aspects related to the operational performance, that is, those influencing the security of the users and the metrological performance of the measuring system. The development of the second stage counted on the collaboration of national companies from the sector of CNG for vehicles, which permitted the carrying out of multiple calibrations to the measuring systems installed in the CNG dispensers, thus achieving, in a concrete way, valid and reliable technological information of the implemented procedures. (author)

  13. Experimental Results Obtained with Air Liquide Cold Compression System: CERN LHC and SNS Projects

    Science.gov (United States)

    Delcayre, F.; Courty, J.-C.; Hamber, F.; Hilbert, B.; Monneret, E.; Toia, J.-L.

    2006-04-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high-capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC will be detailed. The principles of control for the CCC in series will be detailed.

  14. Performance Evaluation of An Innovative-Vapor- Compression-Desalination System

    Directory of Open Access Journals (Sweden)

    Mirna R. Lubis

    2012-04-01

    Full Text Available Two dominant desalination methods are reverse osmosis (RO and multi-stage flash (MSF. RO requires large capital investment and maintenance, whereas MSF is too energy-intensive. Innovative system of vapor compression desalination is proposed in this study. Comprehensive mathematics model for evaporator is also described. From literature study, it is indicated that very high overall-heat-transfer coefficient for evaporator can be obtained at specific condition by using dropwise condensation in the steam side, and pool boiling in the liquid side. Smooth titanium surface is selected in order to increase dropwise condensation, and resist corrosion. To maximize energy efficiency, a cogeneration scheme of a combined cycle consisting of gas turbine, boiler heat recovery, and steam turbine that drivescompressor is used. The resource for combined cycle is relatively too high for the compressor requirement. Excess power can be used to generate electricity for internal and/or externalconsumptions, and sold to open market. Four evaporator stages are used. Evaporator is fed by seawater, with assumption of 3.5% salt contents. Boiling brine (7% salt is boiled in low pressure side of the heat exchanger, and condensed vapor is condensed in high pressure side of the heat exchanger. Condensed steam flows at velocity of 1.52 m/s, so that it maximize the heat transfer coefficient. This unit is designed in order to produce 10 million gallon/day, and assumed it is financed with 5%, 30 years of passive obligation. Three cases are evaluated in order to determine recommended condition to obtain the lowest fixed capital investment. Based on the evaluation, it is possible to establish four-stage unit of mechanical vapor compression distillation with capital $31,723,885.

  15. Lattice Boltzmann methods for thermal flows: Continuum limit and applications to compressible Rayleigh Taylor systems

    NARCIS (Netherlands)

    Scagliarini, Andrea; Biferale, L.; Sbragaglia, M.; Sugiyama, K.; Toschi, F.

    2010-01-01

    We compute the continuum thermohydrodynamical limit of a new formulation of lattice kinetic equations for thermal compressible flows, recently proposed by Sbragaglia et al. [J. Fluid Mech. 628, 299 (2009)] . We show that the hydrodynamical manifold is given by the correct compressible

  16. Technical and economic assessment of fluidized-bed-augmented compressed-air energy-storage system: system load following capability

    Energy Technology Data Exchange (ETDEWEB)

    Lessard, R.D.; Blecher, W.A.; Merrick, D.

    1981-09-01

    The load-following capability of fluidized bed combustion-augmented compressed air energy storage systems was evaluated. The results are presented in two parts. The first part is an Executive Summary which provides a concise overview of all major elements of the study including the conclusions, and, second, a detailed technical report describing the part-load and load following capability of both the pressurized fluid bed combustor and the entire pressurized fluid bed combustor/compressed air energy storage system. The specific tasks in this investigation were to: define the steady-state, part-load operation of the CAES open-bed PFBC; estimate the steady-state, part-load performance of the PFBC/CAES system and evaluate any possible operational constraints; simulate the performance of the PFBC/CAES system during transient operation and assess the load following capability of the system; and establish a start-up procedure for the open-bed PFBC and evaluate the impact of this procedure. The conclusions are encouraging and indicate that the open-bed PFBC/CAES power plant should provide good part-load and transient performance, and should have no major equipment-related constraints, specifically, no major problems associated with the performance or design of either the open-end PFBC or the PFBC/CAES power plant in steady-state, part-load operation are envisioned. The open-bed PFBC/CAES power plant would have a load following capability which would be responsive to electric utility requirements for a peak-load power plant. The open-bed PFBC could be brought to full operating conditions within 15 min after routine shutdown, by employing a hot-start mode of operation. The PFBC/CAES system would be capable of rapid changes in output power (12% of design load per minute) over a wide output power range (25% to 100% of design output). (LCL)

  17. Internal heat exchange in an ejector-compression solar refrigeration system with R142b

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Joge I; Estrada, Claudio A; Best, Roberto [Centro de Investigacion en Energia, UNAM, Temixco, Morelos (Mexico); Dorantes Ruben, J [Departamento de Energia, UNAM Azcapotzalco, Mexico, D.F. (Mexico)

    2000-07-01

    One way to use more efficiently the actual energy transfer in the ejector-compression system, is the use of heat exchangers between some of the components. The inclusion of two heat exchangers, preheater and precooler, is considered in a basic ejector-compression refrigeration system with refrigerant 142b. This study accounts for the energy and exergy efficiencies. COP and {epsilon}, according to parameter variations such as ejector efficiency, generation temperature with different superheating, condensation temperature and heat exchangers effectiveness. As known, the most important parameters in ejector-compression system analysis are the entrain-ment ratio U and system efficiencies COP and {epsilon}. The highest system COP and {epsilon}, as the entrainment ratio U, correspond to the highest exchangers effectiveness, highest superheating generator temperatures, highest ejector efficiency and lowest condenser temperature. For the COP and {epsilon} ratios, their maxima correspond to the same independent variables aforementioned for one of the higher superheating generator temperatures. In this case, this result indicates that the exergy efficiency {epsilon} does not contradict the information given by energy efficiency COP. So, to select correctly and optimum design condition, is enough to employ the COP ratio, which maximum value for the data shown corresponds to a superheating generator temperature of about 110 Celsius degrees, that can only be reached by evacuated tubular collectors or CPC solar concentrators. [Spanish] Una forma de usar mas eficientemente la transferencia real de energia en el sistema eyector-compresion es el uso de intercambiadores de calor entre algunos de los componentes. La inclusion de dos intercambiadores de calor precalentador y pre-enfriador se considera en un sistema de refrigeracion eyector-compresion con refrigerante 142b. Este estudio toma en cuenta las eficiencias de energia y exergia, COP y {epsilon}, de acuerdo con las variaciones

  18. Vapor Compression and Thermoelectric Heat Pump Heat Exchangers for a Condensate Distillation System: Design and Experiment

    Science.gov (United States)

    Erickson, Lisa R.; Ungar, Eugene K.

    2013-01-01

    Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.

  19. The effects of two different types of bandage contact lenses on the healthy canine eye.

    Science.gov (United States)

    Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse

    2018-02-06

    To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.

  20. Combating Impairments in Multi-carrier Systems: A Compressed Sensing Approach

    KAUST Repository

    Al-Shuhail, Shamael

    2015-05-01

    Multi-carrier systems suffer from several impairments, and communication system engineers use powerful signal processing tools to combat these impairments and keep up with the capacity/rate demands. Compressed sensing (CS) is one such tool that allows recovering any sparse signal, requiring only a few measurements in a domain that is incoherent with the domain of sparsity. Almost all signals of interest have some degree of sparsity, and in this work we utilize the sparsity of impairments in orthogonal frequency division multiplexing (OFDM) and its variants (i.e., orthogonal frequency division multiplexing access (OFDMA) and single-carrier frequency-division multiple access (SC-FDMA)) to combat them using CS. We start with the problem of peak-to-average power ratio (PAPR) reduction in OFDM. OFDM signals suffer from high PAPR and clipping is the simplest PAPR reduction scheme. However, clipping introduces inband distortions that result in compromised performance and hence needs to be mitigated at the receiver. Due to the high PAPR nature of the OFDM signal, only a few instances are clipped, these clipping distortions can be recovered at the receiver by employing CS. We then extend the proposed clipping recovery scheme to an interleaved OFDMA system. Interleaved OFDMA presents a special structure that result in only self-inflicted clipping distortions. In this work, we prove that distortions do not spread over multiple users (while utilizing interleaved carrier assignment in OFDMA) and construct a CS system that recovers the clipping distortions on each user. Finally, we address the problem of narrowband interference (NBI) in SC-FDMA. Unlike OFDM and OFDMA systems, SC-FDMA does not suffer from high PAPR, but (as the data is encoded in time domain) is seriously vulnerable to information loss owing to NBI. Utilizing the sparse nature of NBI (in frequency domain) we combat its effect on SC-FDMA system by CS recovery.

  1. Compressible Fluid Suspension Performance Testing

    National Research Council Canada - National Science Library

    Hoogterp, Francis

    2003-01-01

    ... compressible fluid suspension system that was designed and installed on the vehicle by DTI. The purpose of the tests was to evaluate the possible performance benefits of the compressible fluid suspension system...

  2. Compressive Strength Properties of Natural Gas Hydrate Pellet by Continuous Extrusion from a Twin-Roll System

    Directory of Open Access Journals (Sweden)

    Yun-Hoo Lee

    2013-01-01

    Full Text Available This study investigates the compressive strength of natural gas hydrate (NGH pellet strip extruded from die holes of a twin-roll press for continuous pelletizing (TPCP. The lab-scale TPCP was newly developed, where NGH powder was continuously fed and extruded into strip-type pellet between twin rolls. The system was specifically designed for future expansion towards mass production of solid form NGH. It is shown that the compressive strength of NGH pellet strip heavily depends on parameters in the extrusion process, such as feeding pressure, pressure ratio, and rotational speed. The mechanism of TPCP, along with the compressive strength and density of pellets, is discussed in terms of its feasibility for producing NGH pellets in the future.

  3. Evaluation of Two Compressed Air Foam Systems for Culling Caged Layer Hens

    Directory of Open Access Journals (Sweden)

    Eric R. Benson

    2018-04-01

    Full Text Available Outbreaks of avian influenza (AI and other highly contagious poultry diseases continue to be a concern for those involved in the poultry industry. In the situation of an outbreak, emergency depopulation of the birds involved is necessary. In this project, two compressed air foam systems (CAFS were evaluated for mass emergency depopulation of layer hens in a manure belt equipped cage system. In both experiments, a randomized block design was used with multiple commercial layer hens treated with one of three randomly selected depopulation methods: CAFS, CAFS with CO2 gas, and CO2 gas. In Experiment 1, a Rowe manufactured CAFS was used, a selection of birds were instrumented, and the time to unconsciousness, brain death, altered terminal cardiac activity and motion cessation were recorded. CAFS with and without CO2 was faster to unconsciousness, however, the other parameters were not statistically significant. In Experiment 2, a custom Hale based CAFS was used to evaluate the impact of bird age, a selection of birds were instrumented, and the time to motion cessation was recorded. The difference in time to cessation of movement between pullets and spent hens using CAFS was not statistically significant. Both CAFS depopulate caged layers, however, there was no benefit to including CO2.

  4. Evaluation of Two Compressed Air Foam Systems for Culling Caged Layer Hens.

    Science.gov (United States)

    Benson, Eric R; Weiher, Jaclyn A; Alphin, Robert L; Farnell, Morgan; Hougentogler, Daniel P

    2018-04-24

    Outbreaks of avian influenza (AI) and other highly contagious poultry diseases continue to be a concern for those involved in the poultry industry. In the situation of an outbreak, emergency depopulation of the birds involved is necessary. In this project, two compressed air foam systems (CAFS) were evaluated for mass emergency depopulation of layer hens in a manure belt equipped cage system. In both experiments, a randomized block design was used with multiple commercial layer hens treated with one of three randomly selected depopulation methods: CAFS, CAFS with CO₂ gas, and CO₂ gas. In Experiment 1, a Rowe manufactured CAFS was used, a selection of birds were instrumented, and the time to unconsciousness, brain death, altered terminal cardiac activity and motion cessation were recorded. CAFS with and without CO₂ was faster to unconsciousness, however, the other parameters were not statistically significant. In Experiment 2, a custom Hale based CAFS was used to evaluate the impact of bird age, a selection of birds were instrumented, and the time to motion cessation was recorded. The difference in time to cessation of movement between pullets and spent hens using CAFS was not statistically significant. Both CAFS depopulate caged layers, however, there was no benefit to including CO₂.

  5. DNABIT Compress - Genome compression algorithm.

    Science.gov (United States)

    Rajarajeswari, Pothuraju; Apparao, Allam

    2011-01-22

    Data compression is concerned with how information is organized in data. Efficient storage means removal of redundancy from the data being stored in the DNA molecule. Data compression algorithms remove redundancy and are used to understand biologically important molecules. We present a compression algorithm, "DNABIT Compress" for DNA sequences based on a novel algorithm of assigning binary bits for smaller segments of DNA bases to compress both repetitive and non repetitive DNA sequence. Our proposed algorithm achieves the best compression ratio for DNA sequences for larger genome. Significantly better compression results show that "DNABIT Compress" algorithm is the best among the remaining compression algorithms. While achieving the best compression ratios for DNA sequences (Genomes),our new DNABIT Compress algorithm significantly improves the running time of all previous DNA compression programs. Assigning binary bits (Unique BIT CODE) for (Exact Repeats, Reverse Repeats) fragments of DNA sequence is also a unique concept introduced in this algorithm for the first time in DNA compression. This proposed new algorithm could achieve the best compression ratio as much as 1.58 bits/bases where the existing best methods could not achieve a ratio less than 1.72 bits/bases.

  6. Compression stockings

    Science.gov (United States)

    Call your health insurance or prescription plan: Find out if they pay for compression stockings. Ask if your durable medical equipment benefit pays for compression stockings. Get a prescription from your doctor. Find a medical equipment store where they can ...

  7. A Kinect-Based Real-Time Compressive Tracking Prototype System for Amphibious Spherical Robots

    Directory of Open Access Journals (Sweden)

    Shaowu Pan

    2015-04-01

    Full Text Available A visual tracking system is essential as a basis for visual servoing, autonomous navigation, path planning, robot-human interaction and other robotic functions. To execute various tasks in diverse and ever-changing environments, a mobile robot requires high levels of robustness, precision, environmental adaptability and real-time performance of the visual tracking system. In keeping with the application characteristics of our amphibious spherical robot, which was proposed for flexible and economical underwater exploration in 2012, an improved RGB-D visual tracking algorithm is proposed and implemented. Given the limited power source and computational capabilities of mobile robots, compressive tracking (CT, which is the effective and efficient algorithm that was proposed in 2012, was selected as the basis of the proposed algorithm to process colour images. A Kalman filter with a second-order motion model was implemented to predict the state of the target and select candidate patches or samples for the CT tracker. In addition, a variance ratio features shift (VR-V tracker with a Kalman estimation mechanism was used to process depth images. Using a feedback strategy, the depth tracking results were used to assist the CT tracker in updating classifier parameters at an adaptive rate. In this way, most of the deficiencies of CT, including drift and poor robustness to occlusion and high-speed target motion, were partly solved. To evaluate the proposed algorithm, a Microsoft Kinect sensor, which combines colour and infrared depth cameras, was adopted for use in a prototype of the robotic tracking system. The experimental results with various image sequences demonstrated the effectiveness, robustness and real-time performance of the tracking system.

  8. A Kinect-based real-time compressive tracking prototype system for amphibious spherical robots.

    Science.gov (United States)

    Pan, Shaowu; Shi, Liwei; Guo, Shuxiang

    2015-04-08

    A visual tracking system is essential as a basis for visual servoing, autonomous navigation, path planning, robot-human interaction and other robotic functions. To execute various tasks in diverse and ever-changing environments, a mobile robot requires high levels of robustness, precision, environmental adaptability and real-time performance of the visual tracking system. In keeping with the application characteristics of our amphibious spherical robot, which was proposed for flexible and economical underwater exploration in 2012, an improved RGB-D visual tracking algorithm is proposed and implemented. Given the limited power source and computational capabilities of mobile robots, compressive tracking (CT), which is the effective and efficient algorithm that was proposed in 2012, was selected as the basis of the proposed algorithm to process colour images. A Kalman filter with a second-order motion model was implemented to predict the state of the target and select candidate patches or samples for the CT tracker. In addition, a variance ratio features shift (VR-V) tracker with a Kalman estimation mechanism was used to process depth images. Using a feedback strategy, the depth tracking results were used to assist the CT tracker in updating classifier parameters at an adaptive rate. In this way, most of the deficiencies of CT, including drift and poor robustness to occlusion and high-speed target motion, were partly solved. To evaluate the proposed algorithm, a Microsoft Kinect sensor, which combines colour and infrared depth cameras, was adopted for use in a prototype of the robotic tracking system. The experimental results with various image sequences demonstrated the effectiveness, robustness and real-time performance of the tracking system.

  9. Mathematical and numerical analysis of systems of compressible hydrodynamics and photonics with polar coordinates

    International Nuclear Information System (INIS)

    Meltz, Bertrand

    2015-01-01

    This thesis deals with the mathematical and numerical analysis of the systems of compressible hydrodynamics and radiative transfer. More precisely, we study the derivation of numerical methods with 2D polar coordinates (one for the radius, one for the angle) where equations are discretized on regular polar grids. On one hand, these methods are well-suited for the simulation of flows with polar symmetries since they preserve these symmetries by construction. On the other hand, such coordinates systems introduce geometrical singularities as well as geometrical source terms which must be carefully treated. The first part of this document is devoted to the study of hydrodynamics equations, or Euler equations. We propose a new class of arbitrary high-order numerical schemes in both space and time and rely on directional splitting methods for the resolution of 2D equations. Each sub-system is solved using a Lagrange+Remap solver. We study the influence of the r=0 geometrical singularities of the cylindrical and spherical coordinates systems on the precision of the 2D numerical solutions. The second part of this document is devoted to the study of radiative transfer equations. In these equations, the unknowns depend on a large number of variables and a stiff source term is involved. The main difficulty consists in capturing the correct asymptotic behavior on coarse grids. We first construct a class of models where the radiative intensity is projected on a truncated spherical harmonics basis in order to lower the number of mathematical dimensions. Then we propose an Asymptotic Preserving scheme built in polar coordinates and we show that the scheme capture the correct diffusion limit in the radial direction as well as in the polar direction. (author) [fr

  10. MGN V RADAR SYSTEM DERIVED MIDR COMPRESSED THRICE V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains the Magellan Compressed Thrice Mosaicked Image Data Records (C3-MIDRs) which consists of mosaics generated by computing 3x3 pixel arithmetic...

  11. Oil flooded compression cycle enhancement for two-stage heat pump in cold climate region: System design and theoretical analysis

    International Nuclear Information System (INIS)

    Luo, Baojun

    2016-01-01

    Highlights: • COP of proposed system improves up to 17.2% compared with vapor injection cycle. • Discharge temperature of proposed system is largely decreased. • Proposed system is beneficial for refrigerant with high compression heat. • Proposed system has potential for applications in cold climate heat pump. - Abstract: In order to improve the performance of air source heat pump in cold climate region, a combined oil flooded compression with regenerator and vapor injection cycle system is suggested in this paper, which integrates oil flooded compression with regenerator into a conventional vapor injection cycle. A mathematical model is developed and parametric studies on this cycle are conducted to evaluate the benefits of the novel system. The performances of the novel system using R410A and R32 are compared with those of vapor injection cycle system. The improvement of coefficient of performance (COP) can reach up to nearly 9% based on the same isentropic efficiency, while 17.2% based on assumption that there is a 10% rise in isentropic efficiency brought by oil flooded compression cycle. The heating capacity is reduced by 8–18% based on the same volumetric efficiency, while could be less than 10% in a practical system. The discharge temperature is largely decreased and can be below 100 °C at −40 °C T_e and 50 °C T_c condition for R32. The theoretical results demonstrate this novel heat pump has a high potential for improving the performance of air source heat pump in cold climate region.

  12. A Novel Hybrid-Fuel Storage System of Compressed Air Energy for China

    Directory of Open Access Journals (Sweden)

    Wenyi Liu

    2014-08-01

    Full Text Available Compressed air energy storage (CAES is a large-scale technology that provides long-duration energy storage. It is promising for balancing the large-scale penetration of intermittent and dispersed sources of power, such as wind and solar power, into electric grids. The existing CAES plants utilize natural gas (NG as fuel. However, China is rich in coal but is deficient in NG; therefore, a hybrid-fuel CAES is proposed and analyzed in this study. Based on the existing CAES plants, the hybrid-fuel CAES incorporates an external combustion heater into the power generation subsystem to heat the air from the recuperator and the air from the high-pressure air turbine. Coal is the fuel for the external combustion heater. The overall efficiency and exergy efficiency of the hybrid-fuel CAES are 61.18% and 59.84%, respectively. Given the same parameters, the cost of electricity (COE of the hybrid-fuel CAES, which requires less NG, is $5.48/MW∙h less than that of the gas-fuel CAES. Although the proposed CAES requires a relatively high investment in the current electricity system in North China, the proposed CAES will be likely to become competitive in the market, provided that the energy supplies are improved and the large scale grid-connection of wind power is realized.

  13. [Heel pressure ulcers. Comparative study between heel protective bandage and hydrocellular dressing with special form for the heel].

    Science.gov (United States)

    Torra i Bou, Joan-Enric; Rueda López, Justo; Camañes, Gemma; Herrero Narváez, Elias; Blanco Blanco, Joan; Martínez-Esparza, Elvira Hernández; Aneas Alcántara, Jesús; Verdú Soriano, José

    2002-05-01

    The heels, together with the sacra area, are one of the most frequent spots where pressure sores appear here in Spain. Any preventive measure against pressure sores on heels needs be oriented towards two main objectives: effective relief of pressure and its compatibility with localized care and skin inspection in order to detect lesions early on at least once a day. The authors planned a comparative, multi-centered, open, labeled and controlled study in which patients were assigned to two groups receiving these treatments: one received traditional preventive pressure sore treatment and a protective bandage on their heels while the other used a special Allevyn Heel hydrocellular dressing to protect their heels. The patients took part in this study over an eight week period. The response variable used to determine the effectiveness of the preventive measure in this study was the appearance of pressure sores. At the beginning, 130 patients were included in this study, 65 in each one of the treatment groups. In the bandage group, 50 patients finished this study while 61 in the dressing group finished this study. The appearance of pressure sores in the protective bandage group occurred in 44% of the patients, 22 out of 50, while in the dressing group, the occurrence rate was 3.3%, 2 out of 61 patients with a value of "ji" squared p pressure sore brought us a value of relative risk of 13.42 (IC 95%: 3.31-54.3) in the group wearing the protective bandage compared to the group wearing the dressing. The results of this study allow us to accept as valid the alternate hypothesis that there exist significant statistical differences between both treatment methods in favor of the Allevyn Heel dressing instead of the protective heel bandage. The use of this dressing, even though it is more expensive a priori than the protective bandage, in terms of unit cost for the product, has proven to be more effective in preventing pressure sores, and cheaper than the protective bandage if

  14. Annual performance investigation and economic analysis of heating systems with a compression-assisted air source absorption heat pump

    International Nuclear Information System (INIS)

    Wu, Wei; Shi, Wenxing; Wang, Baolong; Li, Xianting

    2015-01-01

    Highlights: • Optimal compression ratio of CASAHP is obtained for the maximum energy saving rate. • Annual performance is improved by 10–20% compared to ASAHP without compression. • Energy saving rate is 17.7–29.2% and investment is reduced to 30–60% for CASAHP. • Both compression and partial-design enhance the economy with given energy saving. • Payback time is reduced from 12–32 to 3–6 years by compression and partial-design. - Abstract: The compression-assisted air source absorption heat pump (CASAHP) is a promising alternative heating system in severe operating conditions. In this research, parameter studies on the annual performance under various compression ratios (CRs) and source temperatures are performed to achieve the maximum energy saving rates (ESRs). Economic analyses of the CASAHP under different CRs and partial-design ratios are conducted to obtain an optimal design that considers both energy savings and economy improvements. The results show that the optimal CR becomes higher in colder regions and with lower heat source temperatures. For a source temperature of 130 °C, the optimal CR values in all of the cities are within 2.0. For source temperatures from 100 to 130 °C, the maximum ESR is in the range of 17.7–29.2% in the studied cities. The efficiency improvement rate (EIR) caused by compression in a severe source condition can reach 10.0–20.0%. From the viewpoint of economy, the relative investment of CASAHP is reduced to 30–60% with a CR of 2.0–3.0. With a 2–6% sacrifice in ESR, the payback period can be reduced from 12–32 to 5–9 years using compression. Partial-design of the CASAHP can further reduce the payback period to 3–6 years with a partial-design ratio of 50% and a CR of 2.8. Additionally, CRs and partial-design ratios are designed comprehensively by seeking the maximum ESR for a given acceptable payback period

  15. Evaluation of the safety and efficacy of therapeutic bandage contact lenses on post-cataract surgery patients.

    Science.gov (United States)

    Shi, Dan-Na; Song, Hang; Ding, Tong; Qiu, Wei-Qiang; Wang, Wei

    2018-01-01

    To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index (OSDI) questionnaire, slit-lamp microscope examination of tear break-up time (TBUT), corneal fluorescein score (CFS), tear meniscus height (TMH) together with anterior segment optical coherence tomography (AS-OCT) and corneal topography were evaluated preoperatively and postoperatively. The subjective feeling ( P =0.004), TBUT ( P <0.001) and TMH ( P =0.02) post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree ( P =0.004) and TMH ( P =0.01) of group two were still worse than group one. Moreover, TBUT ( P <0.001) and CFS ( P =0.004) of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery.

  16. Influence of Elastic Bandage and Neoprene Sleeve on Knee Position Sense and Pain in Subjects with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Basir Majdoleslami

    2003-12-01

    Full Text Available Objective: to investigate whether a neoprene sleeve and elastic bandage around the knee joint of subjects with knee osteoarthritis (OA would , in short term (a reduce pain (b improve knee joint position sense and comparison of their effect with each other if they have. Materials & Methods: In a semi-experimental study, 30 subjects (11 men, 19 women, age between 33-75 with unilateral knee OA. Subjects had to have at least 2cm from 10cm visual analogue scale (VAS of knee pain for study entry.All patients were randomly assigned to either an elastic bandage or a neoprene sleeve. One week later they were assigned to the opposite selection. Joint position sense was assessed in the sitting position using an electrogoniometer and pain by VAS where 0cm equals no pain and 10 cm equals worst pain. Knee pain and JPS were assessed for each selection one week apart. During each visit assessment were performed at baseline and after 20 min of bandage/neoprene sleeve application. Results: the mean of scores for knee variables JPS and VAS was taken and paired-t test and Wilcoxon signed rank test was employed to calculate the different between two trails. Neoprene sleeve had significant effect on knee JPS (P=0.037. But elastic bandage had no effect (P=0.631. Both of them had significantly reduced knee pain. (P=0.000 Conclusion: In subjects with both neoprene sleeve and elastic bandage reduced knee pain with more effect of neoprene sleeve. Only the neoprene sleeve had effect on knee JPS.

  17. Evaluation of the safety and efficacy of therapeutic bandage contact lenses on post-cataract surgery patients

    Directory of Open Access Journals (Sweden)

    Dan-Na Shi

    2018-02-01

    Full Text Available AIM: To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS: A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index (OSDI questionnaire, slit-lamp microscope examination of tear break-up time (TBUT, corneal fluorescein score (CFS, tear meniscus height (TMH together with anterior segment optical coherence tomography (AS-OCT and corneal topography were evaluated preoperatively and postoperatively. RESULTS: The subjective feeling (P=0.004, TBUT (P<0.001 and TMH (P=0.02 post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree (P=0.004 and TMH (P=0.01 of group two were still worse than group one. Moreover, TBUT (P<0.001 and CFS (P=0.004 of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. CONCLUSION: Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery.

  18. Performance of the 10-kV, 5-MA pulsed-power system for the FRX-C compression experiment

    International Nuclear Information System (INIS)

    Rej, D.J.; Waganaar, W.J.

    1991-01-01

    Performance data are presented for the 10-kV, 5-MA, 1.5-MJ pulsed-power system developed for the Los Alamos magnetic fusion facility FRX-C. This system energizes a low-inductance magnet for the high-power, compression heating of compact toroid plasmas. An ignitron-switched, 20-mF, 10-kV, 4-MA capacitor bank is discharged to produce the main compression field, while an inductively-isolated, 10-mF, 10-kV, 1-MA bank generates an initial magnetic field to accept the translated plasma. To date, the complete system has successfully operated for two years and approximately 2000 high-power discharges. Component performance during typical and fault-mode operation is reviewed. 5 refs., 5 figs

  19. Pneumatic antishock garment inflation activates the human sympathetic nervous system by abdominal compression.

    Science.gov (United States)

    Garvin, Nathan M; Levine, Benjamin D; Raven, Peter B; Pawelczyk, James A

    2014-01-01

    Pneumatic antishock garments (PASG) have been proposed to exert their blood pressure-raising effect mechanically, i.e. by increasing venous return and vascular resistance of the lower body. We tested whether, alternatively, PASG inflation activates the sympathetic nervous system. Five men and four women wore PASG while mean arterial pressure (MAP), muscle sympathetic nerve activity (MSNA), heart rate and stroke volume were measured. One leg bladder (LEG) and the abdominal bladder (ABD) of the trousers were inflated individually and in combination (ABD+LEG), at 60 or 90 mmHg for 3 min. By the end of 3 min of inflation, conditions that included the ABD region caused significant increases in MAP in a dose-dependent fashion (7 ± 2, 8 ± 3, 14 ± 4 and 13 ± 5 mmHg for ABD60, ABD+LEG60, ABD90 and ABD+LEG90, respectively, P < 0.05). Likewise, inflation that included ABD caused significant increases in total MSNA compared with control values [306 ± 70, 426 ± 98 and 247 ± 79 units for ABD60, ABD90 and ABD+LEG90, respectively, P < 0.05 (units = burst frequency × burst amplitude]. There were no changes in MAP or MSNA in the LEG-alone conditions. The ABD inflation also caused a significant decrease in stroke volume (-11 ± 3 and -10 ± 3 ml per beat in ABD90 and ABD+LEG90, respectively, P < 0.05) with no change in cardiac output. Neither cardiopulmonary receptor deactivation nor mechanical effects can account for a slowly developing rise in both sympathetic activity and blood pressure during ABD inflation. Rather, these data provide direct evidence that PASG inflation activates the sympathetic nervous system secondarily to abdominal, but not leg, compression.

  20. Comparison between various patch wise strategies for reconstruction of ultra-spectral cubes captured with a compressive sensing system

    Science.gov (United States)

    Oiknine, Yaniv; August, Isaac Y.; Revah, Liat; Stern, Adrian

    2016-05-01

    Recently we introduced a Compressive Sensing Miniature Ultra-Spectral Imaging (CS-MUSI) system. The system is based on a single Liquid Crystal (LC) cell and a parallel sensor array where the liquid crystal cell performs spectral encoding. Within the framework of compressive sensing, the CS-MUSI system is able to reconstruct ultra-spectral cubes captured with only an amount of ~10% samples compared to a conventional system. Despite the compression, the technique is extremely complex computationally, because reconstruction of ultra-spectral images requires processing huge data cubes of Gigavoxel size. Fortunately, the computational effort can be alleviated by using separable operation. An additional way to reduce the reconstruction effort is to perform the reconstructions on patches. In this work, we consider processing on various patch shapes. We present an experimental comparison between various patch shapes chosen to process the ultra-spectral data captured with CS-MUSI system. The patches may be one dimensional (1D) for which the reconstruction is carried out spatially pixel-wise, or two dimensional (2D) - working on spatial rows/columns of the ultra-spectral cube, as well as three dimensional (3D).

  1. A Fully Integrated Wireless Compressed Sensing Neural Signal Acquisition System for Chronic Recording and Brain Machine Interface.

    Science.gov (United States)

    Liu, Xilin; Zhang, Milin; Xiong, Tao; Richardson, Andrew G; Lucas, Timothy H; Chin, Peter S; Etienne-Cummings, Ralph; Tran, Trac D; Van der Spiegel, Jan

    2016-07-18

    Reliable, multi-channel neural recording is critical to the neuroscience research and clinical treatment. However, most hardware development of fully integrated, multi-channel wireless neural recorders to-date, is still in the proof-of-concept stage. To be ready for practical use, the trade-offs between performance, power consumption, device size, robustness, and compatibility need to be carefully taken into account. This paper presents an optimized wireless compressed sensing neural signal recording system. The system takes advantages of both custom integrated circuits and universal compatible wireless solutions. The proposed system includes an implantable wireless system-on-chip (SoC) and an external wireless relay. The SoC integrates 16-channel low-noise neural amplifiers, programmable filters and gain stages, a SAR ADC, a real-time compressed sensing module, and a near field wireless power and data transmission link. The external relay integrates a 32 bit low-power microcontroller with Bluetooth 4.0 wireless module, a programming interface, and an inductive charging unit. The SoC achieves high signal recording quality with minimized power consumption, while reducing the risk of infection from through-skin connectors. The external relay maximizes the compatibility and programmability. The proposed compressed sensing module is highly configurable, featuring a SNDR of 9.78 dB with a compression ratio of 8×. The SoC has been fabricated in a 180 nm standard CMOS technology, occupying 2.1 mm × 0.6 mm silicon area. A pre-implantable system has been assembled to demonstrate the proposed paradigm. The developed system has been successfully used for long-term wireless neural recording in freely behaving rhesus monkey.

  2. Thermodynamic analysis of a novel tri-generation system based on compressed air energy storage and pneumatic motor

    International Nuclear Information System (INIS)

    Liu, Jin-Long; Wang, Jian-Hua

    2015-01-01

    Based on CAES (compressed air energy storage) and PM (pneumatic motor), a novel tri-generation system (heat energy, mechanical energy and cooling power) is proposed in this paper. Both the cheap electricity generated at night and the excess power from undelivered renewable energy due to instability, can be stored as compressed air and hot water by the proposed system. When energy is in great demand, the compressed air stored in this system is released to drive PM to generate mechanical power. The discharged air from PM can be further utilized as valuable cooling power. Compared to conventional CAES systems, the biggest characteristic of the proposed system is that the discharged air usually abandoned is used as cooling power. In order to study the performances of this system, a thermodynamic analysis and an experimental investigation are carried out. The thermodynamic model is validated by the experimental data. Using the validated thermodynamic model, the mechanical energy output, cooling capacity and temperature of discharged air, as well as the efficiency of the system are analyzed. The theoretical analysis indicates that the additional application of discharged air can improve total energy efficiency by 20–30%. Therefore, this system is very worthy of consideration and being popularized. - Highlights: • The proposed system can provide mechanical energy, heat energy and cooling power. • The exhaust air of pneumatic motor is used as cooling power instead of abandoned. • A thermodynamic model of the proposed system is constructed and validated. • The effects of several parameters on system performance are examined. • The proposed system can improve total energy efficiency of CAES system by 20–30%.

  3. Methodology for the energy analysis of compressed air systems; Metodologia para analisis energetico de sistemas de aire comprimido

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, T; Ambriz, J J; Romero, H [Universidad Autonoma Metropolitana-Iztapalapa, Mexico, D. F. (Mexico)

    1993-12-31

    In this paper a methodology for the diagnosis of compressed air systems, for the identification of the potential energy saving is presented. The methodology consists in detecting the largest number of possible ways of energy saving. For this purpose it is divided into three parts: 1. Compressed air generation. 2. Compressed air distribution. 3. Compressed air users. For each one of the parts, the type of information required to perform the diagnosis study, as well as the necessary measuring equipment needed, is indicated. Afterwards, the possible saving ways that can be found and the ones that can be feasible, are analyzed. [Espanol] En este trabajo se presenta una metodologia para diagnosticar sistemas de aire comprimido, para identificar los potenciales de ahorro de energia. La metodologia consiste en detectar el mayor numero de posibles medidas de ahorro, para lo cual se divide en tres partes: 1. Generacion de aire comprimido. 2. Distribucion del aire comprimido. 3 Usuarios de aire comprimido. Para cada una de las partes se indica el tipo de informacion requerida para realizar el estudio de diagnostico, asi como el uso de equipo necesario de medicion. Despues se analizan las posibles medidas de ahorro que se pueden encontrar y las que pueden ser viables.

  4. Methodology for the energy analysis of compressed air systems; Metodologia para analisis energetico de sistemas de aire comprimido

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, T.; Ambriz, J. J.; Romero, H. [Universidad Autonoma Metropolitana-Iztapalapa, Mexico, D. F. (Mexico)

    1992-12-31

    In this paper a methodology for the diagnosis of compressed air systems, for the identification of the potential energy saving is presented. The methodology consists in detecting the largest number of possible ways of energy saving. For this purpose it is divided into three parts: 1. Compressed air generation. 2. Compressed air distribution. 3. Compressed air users. For each one of the parts, the type of information required to perform the diagnosis study, as well as the necessary measuring equipment needed, is indicated. Afterwards, the possible saving ways that can be found and the ones that can be feasible, are analyzed. [Espanol] En este trabajo se presenta una metodologia para diagnosticar sistemas de aire comprimido, para identificar los potenciales de ahorro de energia. La metodologia consiste en detectar el mayor numero de posibles medidas de ahorro, para lo cual se divide en tres partes: 1. Generacion de aire comprimido. 2. Distribucion del aire comprimido. 3 Usuarios de aire comprimido. Para cada una de las partes se indica el tipo de informacion requerida para realizar el estudio de diagnostico, asi como el uso de equipo necesario de medicion. Despues se analizan las posibles medidas de ahorro que se pueden encontrar y las que pueden ser viables.

  5. Cooling performance and energy saving of a compression-absorption refrigeration system driven by a gas engine

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z.G.; Guo, K.H. [Sun Yat-Sen University, Guangzhou (China). Engineering School

    2006-07-01

    The prototype of combined vapour compression-absorption refrigeration system was set up, where a gas engine drove directly an open screw compressor in a vapour compression refrigeration chiller and waste heat from the gas engine was used to operate absorption refrigeration cycle. The experimental procedure and results showed that the combined refrigeration system was feasible. The cooling capacity of the prototype reached about 589 kW at the Chinese rated conditions of air conditioning (the inlet and outlet temperatures of chilled water are 12 and 7{sup o}C, the inlet and outlet temperatures of cooling water are 30 and 35{sup o}C, respectively). Primary energy rate (PER) and comparative primary energy saving were used to evaluate energy utilization efficiency of the combined refrigeration system. The calculated results showed that the PER of the prototype was about 1.81 and the prototype saved more than 25% of primary energy compared to a conventional electrically driven vapour compression refrigeration unit. Error analysis showed that the total error of the combined cooling system measurement was about 4.2% in this work. (author)

  6. Optimization of the segmented method for optical compression and multiplexing system

    Science.gov (United States)

    Al Falou, Ayman

    2002-05-01

    Because of the constant increasing demands of images exchange, and despite the ever increasing bandwidth of the networks, compression and multiplexing of images is becoming inseparable from their generation and display. For high resolution real time motion pictures, electronic performing of compression requires complex and time-consuming processing units. On the contrary, by its inherent bi-dimensional character, coherent optics is well fitted to perform such processes that are basically bi-dimensional data handling in the Fourier domain. Additionally, the main limiting factor that was the maximum frame rate is vanishing because of the recent improvement of spatial light modulator technology. The purpose of this communication is to benefit from recent optical correlation algorithms. The segmented filtering used to store multi-references in a given space bandwidth product optical filter can be applied to networks to compress and multiplex images in a given bandwidth channel.

  7. The pre-compression system of the toroidal field coils in ITER

    International Nuclear Information System (INIS)

    Knaster, J.; Ferrari, M.; Jong, C.; Vollmann, T.

    2007-01-01

    The toroidal field (TF) coils of ITER will undergo out-of-plane forces caused by the poloidal fields required to confine the plasma. These forces will be supported against overturning moments by links between the coils. In turn, these links consist of the inner intercoil structure (IIC), which is composed of two pairs (placed at the top and bottom part of the inboard leg) of four sets of poloidal shear keys inserted in slots between adjacent coils, and the outer intercoil structure (OIS) formed by four bands of shear panels on the outboard leg. The magnetic forces during energization of ITER would cause at IIC locations at toroidal gap between adjacent TF coils of 0.35 mm; during plasma operation this value could reach >1 mm causing a loosening of the keys and intensifying stress concentrations. This undesired effect will be suppressed by the application of a centripetal force of 70 MN/coil (35 MN at both the bottom and top part of the inboard leg of each of the 18 TF coils) that will be provided by two sets of three glass fibre/epoxy composite rings submitted to a toroidal hoop force of 100 MN/set. The calculated maximum stress in the rings will occur during the installation phase at room temperature, where the maximum radial elongation (∼25 mm) is required, and it reaches 1/5 of the composite presently estimated ultimate stress. The imposed elongation to reach that force and the lower Young's modulus of the composite compared with that of stainless steel will ease component tolerances and/or settlement effects in the final assembly. The paper describes the evolution in the design of the pre-compression system, from the conceptual phase when two circular cross-sections rings were considered to the present definitive one with three rectangular cross-section rings

  8. Extensive characterisation of advanced manufacturing solutions for the ITER Central Solenoid pre-compression system

    Energy Technology Data Exchange (ETDEWEB)

    Langeslag, S.A.E., E-mail: stefanie.langeslag@cern.ch [CERN, CH-1211 Genève 23 (Switzerland); Sgobba, S. [CERN, CH-1211 Genève 23 (Switzerland); Libeyre, P. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul lez Durance Cedex (France); Marcinek, D.J. [Cracow University of Technology, Warszawska 24, 30-962 Kraków (Poland); Zhang, Z. [CERN, CH-1211 Genève 23 (Switzerland); EPFL, CH-1015 Lausanne (Switzerland)

    2015-10-15

    The ITER Central Solenoid (CS), positioned in the center of the ITER tokamak, will provide a magnetic field, contributing to the confinement of the plasma. The 13 m high CS consists of a vertical stack of 6 independently driven modules, dynamically activated. Resulting opposing currents can lead to high separation forces. A pre-compression structure is implemented to counteract these opposing forces, by realising a continuous 180 MN coil-to-coil contact loading. Preload is applied by mechanical fastening via 9 subunits, positioned along the coil stack, each consisting of 2 outer and 1 inner tie plate. The tie plates therefore need to feature outstanding mechanical behaviour in a large temperature range. High strength, Nitronic®-50 type F XM-19 austenitic stainless steel is selected as candidate material. The linearised stress distribution reaches approximately 250 MPa, leading to a required yield strength of 380 MPa at room temperature. Two different manufacturing methods are being studied for the procurement of these 15 m long tie plates. A welded solution originates from individual head- and slab-forgings, welded together by Gas Metal Arc Welding (GMAW). In parallel, a single piece forged solution is proven feasible, impressively forged in one piece by applying successive open die forging steps, followed by final machining. Maximum internal stress is experienced during cool-down to 4 K as a result of a large difference in thermal contraction between the support system and the coils. Furthermore, the varying magnetic fields in the independently driven coils introduce cyclic loading. Therefore, assessment of the two manufacturing solutions, in terms of both static and dynamic mechanical behaviour, is performed at ambient as well as cryogenic temperature. An extensive characterisation including microstructural and mechanical examination is conducted, evaluating the comparative performance of both solutions, reporting, amongst others, yield strength reaching the

  9. Depopulation of Caged Layer Hens with a Compressed Air Foam System.

    Science.gov (United States)

    Gurung, Shailesh; Hoffman, John; Stringfellow, Kendre; Abi-Ghanem, Daad; Zhao, Dan; Caldwell, David; Lee, Jason; Styles, Darrel; Berghman, Luc; Byrd, James; Farnell, Yuhua; Archer, Gregory; Farnell, Morgan

    2018-01-11

    During the 2014-2015 US highly pathogenic avian influenza (HPAI) outbreak, 50.4 million commercial layers and turkeys were affected, resulting in economic losses of $3.3 billion. Rapid depopulation of infected poultry is vital to contain and eradicate reportable diseases like HPAI. The hypothesis of the experiment was that a compressed air foam (CAF) system may be used as an alternative to carbon dioxide (CO₂) inhalation for depopulating caged layer hens. The objective of this study was to evaluate corticosterone (CORT) and time to cessation of movement (COM) of hens subjected to CAF, CO₂ inhalation, and negative control (NEG) treatments. In Experiment 1, two independent trials were conducted using young and spent hens. Experiment 1 consisted of five treatments: NEG, CO₂ added to a chamber, a CO₂ pre-charged chamber, CAF in cages, and CAF in a chamber. In Experiment 2, only spent hens were randomly assigned to three treatments: CAF in cages, CO₂ added to a chamber, and aspirated foam. Serum CORT levels of young hens were not significantly different among the CAF in cages, CAF in a chamber, NEG control, and CO₂ inhalation treatments. However, spent hens subjected to the CAF in a chamber had significantly higher CORT levels than birds in the rest of the treatments. Times to COM of spent hens subjected to CAF in cages and aspirated foam were significantly greater than of birds exposed to the CO₂ in a chamber treatment. These data suggest that applying CAF in cages is a viable alternative for layer hen depopulation during a reportable disease outbreak.

  10. Depopulation of Caged Layer Hens with a Compressed Air Foam System

    Directory of Open Access Journals (Sweden)

    Shailesh Gurung

    2018-01-01

    Full Text Available During the 2014–2015 US highly pathogenic avian influenza (HPAI outbreak, 50.4 million commercial layers and turkeys were affected, resulting in economic losses of $3.3 billion. Rapid depopulation of infected poultry is vital to contain and eradicate reportable diseases like HPAI. The hypothesis of the experiment was that a compressed air foam (CAF system may be used as an alternative to carbon dioxide (CO2 inhalation for depopulating caged layer hens. The objective of this study was to evaluate corticosterone (CORT and time to cessation of movement (COM of hens subjected to CAF, CO2 inhalation, and negative control (NEG treatments. In Experiment 1, two independent trials were conducted using young and spent hens. Experiment 1 consisted of five treatments: NEG, CO2 added to a chamber, a CO2 pre-charged chamber, CAF in cages, and CAF in a chamber. In Experiment 2, only spent hens were randomly assigned to three treatments: CAF in cages, CO2 added to a chamber, and aspirated foam. Serum CORT levels of young hens were not significantly different among the CAF in cages, CAF in a chamber, NEG control, and CO2 inhalation treatments. However, spent hens subjected to the CAF in a chamber had significantly higher CORT levels than birds in the rest of the treatments. Times to COM of spent hens subjected to CAF in cages and aspirated foam were significantly greater than of birds exposed to the CO2 in a chamber treatment. These data suggest that applying CAF in cages is a viable alternative for layer hen depopulation during a reportable disease outbreak.

  11. Method and algorithm for efficient calibration of compressive hyperspectral imaging system based on a liquid crystal retarder

    Science.gov (United States)

    Shecter, Liat; Oiknine, Yaniv; August, Isaac; Stern, Adrian

    2017-09-01

    Recently we presented a Compressive Sensing Miniature Ultra-spectral Imaging System (CS-MUSI)1 . This system consists of a single Liquid Crystal (LC) phase retarder as a spectral modulator and a gray scale sensor array to capture a multiplexed signal of the imaged scene. By designing the LC spectral modulator in compliance with the Compressive Sensing (CS) guidelines and applying appropriate algorithms we demonstrated reconstruction of spectral (hyper/ ultra) datacubes from an order of magnitude fewer samples than taken by conventional sensors. The LC modulator is designed to have an effective width of a few tens of micrometers, therefore it is prone to imperfections and spatial nonuniformity. In this work, we present the study of this nonuniformity and present a mathematical algorithm that allows the inference of the spectral transmission over the entire cell area from only a few calibration measurements.

  12. Compressed natural gas (CNG) in fueled systems and the significance of CNG in vehicular transportation

    Energy Technology Data Exchange (ETDEWEB)

    Ayar, G. [Besikduzu, Trabzon (Turkey)

    2006-05-15

    Most NG vehicles operate using compressed natural gas (CNG). CNG's popularity stems, in part, from its clean-burning properties. In addition, more than 85,000 CNG vehicles, including one out of every five transit buses, are operating successfully today. This compressed gas is stored in similar fashion to a car's gasoline tank, attached to the rear, top, or undercarriage of the vehicle in a tube-shaped storage tank. A CNG tank can be filled in a similar manner, and in a similar amount of time, to a gasoline tank. (author)

  13. Relative entropies, suitable weak solutions, and weak-strong uniqueness for the compressible Navier–Stokes system

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Jin, B.J.; Novotný, A.

    2012-01-01

    Roč. 14, č. 4 (2012), s. 717-730 ISSN 1422-6928 R&D Projects: GA ČR GA201/09/0917 Institutional research plan: CEZ:AV0Z10190503 Keywords : suitable weak solution * weak-strong uniqueness * compressible Navier-Stokes system Subject RIV: BA - General Mathematics Impact factor: 1.415, year: 2012 http://link.springer.com/article/10.1007%2Fs00021-011-0091-9

  14. Siting-selection study for the Soyland Power Cooperative, Inc. , compressed-air energy-storage system (CAES)

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    A method used for siting a compressed air energy storage (CAES) system using geotechnical and environmental criteria is explained using the siting of a proposed 220 MW water-compensated CAES plant in Illinois as an example. Information is included on the identification and comparative ranking of 28 geotechnically and environmental sites in Illinois, the examination of fatal flaws, e.g., mitigation, intensive studies, costly studies, permit denials, at 7 sites; and the selection of 3 sites for further geological surveying. (LCL)

  15. Experimental study on two-stage compression refrigeration/heat pump system with dual-cylinder rolling piston compressor

    International Nuclear Information System (INIS)

    Shuxue, Xu; Guoyuan, Ma

    2014-01-01

    A thermodynamically analytical model on the two-stage compression refrigeration/heat pump system with vapor injection was derived. The optimal volume ratio of the high-pressure cylinder to the low-pressure one has been discussed under both cooling and heating conditions. Based on the above research, the prototype was developed and its experimental setup established. A comprehensive experiments for the prototype have been conducted, and the results show that, compared with the single-stage compression heat pump system, the cooling capacity and cooling COP can increase 5%–15% and 10–12%, respectively. Also, the heating capacity with the evaporating temperature ranging from 0.3 to 3 °C is 92–95% of that under the rate condition with the evaporating temperature of 7 °C, and 58% when the evaporation temperature is between −28 °C and −24 °C. -- Highlights: • The volume ratio of the compressor is between 0.65 and 0.78 and the relative vapor injection mass ranges from 15% to 20%. • The cooling capacity and COP of the two-stage compression system can improve 5%–15% and 10%–12%. • The heating capacity can also be improved under low temperature condition

  16. Compressed sensing techniques for receiver based post-compensation of transmitter's nonlinear distortions in OFDM systems

    KAUST Repository

    Owodunni, Damilola S.; Ali, Anum Z.; Quadeer, Ahmed Abdul; Al-Safadi, Ebrahim B.; Hammi, Oualid; Al-Naffouri, Tareq Y.

    2014-01-01

    -domain, and three compressed sensing based algorithms are presented to estimate and compensate for these distortions at the receiver using a few and, at times, even no frequency-domain free carriers (i.e. pilot carriers). The first technique is a conventional

  17. Near-infrared Compressive Line Sensing Imaging System using Individually Addressable Laser Diode Array

    Science.gov (United States)

    2015-05-11

    Of’ R BASE _fo • J.. J ) Oral PrC$&nlalton. published i Oral Presentatoon. not pub!ɝhed ) Vldoo ( 1 PO$ Iot ) Other exp!a.r Near-infrared compress...Micromirror Device (DMD) is a microelectromechanical (MEMS) device. A DMD consists of millions of electrostatically actuated micro- mirrors (or pixels

  18. Subcooled compressed air energy storage system for coproduction of heat, cooling and electricity

    NARCIS (Netherlands)

    Arabkoohsar, A.; Dremark-Larsen, M.; Lorentzen, R.; Andresen, G. B.

    2017-01-01

    Various configurations of compressed air energy storage technology have received attention over the last years due to the advantages that this technology offers relative to other power storage technologies. This work proposes a new configuration of this technology aiming at cogeneration of

  19. Dissipative measure-valued solutions to the compressible Navier-Stokes system

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Gwiazda, P.; Swierczewska-Gwiazda, A.; Wiedemann, E.

    2016-01-01

    Roč. 55, č. 6 (2016), č. článku 141. ISSN 0944-2669 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : singular limit * compressible fluid * viscous fluid Subject RIV: BA - General Mathematics Impact factor: 1.532, year: 2016 http://link.springer.com/article/10.1007/s00526-016-1089-1

  20. Evaluation of shear-compressive strength properties for laminated GFRP composites in electromagnet system

    Science.gov (United States)

    Song, Jun Hee; Kim, Hak Kun; Kim, Sam Yeon

    2014-07-01

    Laminated fiber-reinforced composites can be applied to an insulating structure of a nuclear fusion device. It is necessary to investigate the interlaminar fracture characteristics of the laminated composites for the assurance of design and structural integrity. The three methods used to prepare the glass fiber reinforced plastic composites tested in this study were vacuum pressure impregnation, high pressure laminate (HPL), and prepreg laminate. We discuss the design criteria for safe application of composites and the shear-compressive test methods for evaluating mechanical properties of the material. Shear-compressive tests could be performed successfully using series-type test jigs that were inclined 0°, 30°, 45°, 60°, and 75° to the normal axis. Shear strength depends strongly on the applied compressive stress. The design range of allowable shear stress was extended by use of the appropriate composite fabrication method. HPL had the largest design range, and the allowable interlaminar shear stress was 0.254 times the compressive stress.

  1. DGFEM for dynamical systems describing interaction of compressible fluid and structures

    Czech Academy of Sciences Publication Activity Database

    Feistauer, M.; Hasnedlová, J.; Horáček, Jaromír; Kosík, A.; Kučera, V.

    2013-01-01

    Roč. 254, December 2013 (2013), s. 17-30 ISSN 0377-0427 R&D Projects: GA ČR(CZ) GAP101/11/0207 Institutional support: RVO:61388998 Keywords : compressible Navier–Stokes equations * dynamic elasticity equations * newmark method * flow-induced vibrations of vocal folds Subject RIV: BI - Acoustics Impact factor: 1.077, year: 2013

  2. Fast and Adaptive Lossless On-Board Hyperspectral Data Compression System for Space Applications

    Science.gov (United States)

    Aranki, Nazeeh; Bakhshi, Alireza; Keymeulen, Didier; Klimesh, Matthew

    2009-01-01

    Efficient on-board lossless hyperspectral data compression reduces the data volume necessary to meet NASA and DoD limited downlink capabilities. The techniques also improves signature extraction, object recognition and feature classification capabilities by providing exact reconstructed data on constrained downlink resources. At JPL a novel, adaptive and predictive technique for lossless compression of hyperspectral data was recently developed. This technique uses an adaptive filtering method and achieves a combination of low complexity and compression effectiveness that far exceeds state-of-the-art techniques currently in use. The JPL-developed 'Fast Lossless' algorithm requires no training data or other specific information about the nature of the spectral bands for a fixed instrument dynamic range. It is of low computational complexity and thus well-suited for implementation in hardware, which makes it practical for flight implementations of pushbroom instruments. A prototype of the compressor (and decompressor) of the algorithm is available in software, but this implementation may not meet speed and real-time requirements of some space applications. Hardware acceleration provides performance improvements of 10x-100x vs. the software implementation (about 1M samples/sec on a Pentium IV machine). This paper describes a hardware implementation of the JPL-developed 'Fast Lossless' compression algorithm on a Field Programmable Gate Array (FPGA). The FPGA implementation targets the current state of the art FPGAs (Xilinx Virtex IV and V families) and compresses one sample every clock cycle to provide a fast and practical real-time solution for Space applications.

  3. A study of the thermodynamic performance and CO2 emissions of a vapour compression bio-trigeneration system

    International Nuclear Information System (INIS)

    Parise, Jose A.R.; Castillo Martinez, Luis C.; Pitanga Marques, Rui; Betancourt Mena, Jesus; Vargas, Jose V.C.

    2011-01-01

    A trigeneration system (simultaneous production of heating, cooling and electricity) using a heat engine and a vapour compression chiller, running on biofuel, is studied. A system configuration, capable of meeting the three energy demands in a realistic situation, was devised. It consisted of a compression ignition internal combustion engine driving an electric generator, an electrically driven vapour compression heat pump and a peak boiler. Part of the heating demand was met by recovering waste heat from the engine and the heat pump condenser, thus reducing the overall fuel consumption. New criteria parameters, based on the relative magnitudes of the three energy demands, were defined to evaluate thermal performance and CO 2 emissions. A comparative analysis between the biofuel trigeneration and conventional fossil fuel with no waste heat recovery was carried out, showing that, depending on the relative values of energy demands and on component characteristics, significant reduction on primary energy consumption (up to 50%) and on CO 2 emissions (up to 5% of the original emissions) can be attained with the biofuel-trigeneration combination.

  4. Effects of the Fourth Ventricle Compression in the Regulation of the Autonomic Nervous System: A Randomized Control Trial

    Directory of Open Access Journals (Sweden)

    Ana Paula Cardoso-de-Mello-e-Mello-Ribeiro

    2015-01-01

    Full Text Available Introduction. Dysfunction of the autonomic nervous system is an important factor in the development of chronic pain. Fourth ventricle compression (CV-4 has been shown to influence autonomic activity. Nevertheless, the physiological mechanisms behind these effects remain unclear. Objectives. This study is aimed at evaluating the effects of fourth ventricle compression on the autonomic nervous system. Methods. Forty healthy adults were randomly assigned to an intervention group, on whom CV-4 was performed, or to a control group, who received a placebo intervention (nontherapeutic touch on the occipital bone. In both groups, plasmatic catecholamine levels, blood pressure, and heart rate were measured before and immediately after the intervention. Results. No effects related to the intervention were found. Although a reduction of norepinephrine, systolic blood pressure, and heart rate was found after the intervention, it was not exclusive to the intervention group. In fact, only the control group showed an increment of dopamine levels after intervention. Conclusion. Fourth ventricle compression seems not to have any effect in plasmatic catecholamine levels, blood pressure, or heart rate. Further studies are needed to clarify the CV-4 physiologic mechanisms and clinical efficacy in autonomic regulation and pain treatment.

  5. High Precision Motion Control System for the Two-Stage Light Gas Gun at the Dynamic Compression Sector

    Science.gov (United States)

    Zdanowicz, E.; Guarino, V.; Konrad, C.; Williams, B.; Capatina, D.; D'Amico, K.; Arganbright, N.; Zimmerman, K.; Turneaure, S.; Gupta, Y. M.

    2017-06-01

    The Dynamic Compression Sector (DCS) at the Advanced Photon Source (APS), located at Argonne National Laboratory (ANL), has a diverse set of dynamic compression drivers to obtain time resolved x-ray data in single event, dynamic compression experiments. Because the APS x-ray beam direction is fixed, each driver at DCS must have the capability to move through a large range of linear and angular motions with high precision to accommodate a wide variety of scientific needs. Particularly challenging was the design and implementation of the motion control system for the two-stage light gas gun, which rests on a 26' long structure and weighs over 2 tons. The target must be precisely positioned in the x-ray beam while remaining perpendicular to the gun barrel axis to ensure one-dimensional loading of samples. To accommodate these requirements, the entire structure can pivot through 60° of angular motion and move 10's of inches along four independent linear directions with 0.01° and 10 μm resolution, respectively. This presentation will provide details of how this system was constructed, how it is controlled, and provide examples of the wide range of x-ray/sample geometries that can be accommodated. Work supported by DOE/NNSA.

  6. Optimization of diesel engine performances for a hybrid wind-diesel system with compressed air energy storage

    International Nuclear Information System (INIS)

    Ibrahim, H.; Younes, R.; Basbous, T.; Ilinca, A.; Dimitrova, M.

    2011-01-01

    Electricity supply in remote areas around the world is mostly guaranteed by diesel generators. This relatively inefficient and expensive method is responsible for 1.2 million tons of greenhouse gas (GHG) emission in Canada annually. Some low- and high-penetration wind-diesel hybrid systems (WDS) have been experimented in order to reduce the diesel consumption. We explore the re-engineering of current diesel power plants with the introduction of high-penetration wind systems together with compressed air energy storage (CAES). This is a viable alternative to major the overall percentage of renewable energy and reduce the cost of electricity. In this paper, we present the operative principle of this hybrid system, its economic benefits and advantages and we finally propose a numerical model of each of its components. Moreover, we are demonstrating the energy efficiency of the system, particularly in terms of the increase of the engine performance and the reduction of its fuel consumption illustrated and supported by a village in northern Quebec. -- Highlights: → The Wind-Diesel-Compressed Air Storage System (WDCAS) has a very important commercial potential for remote areas. → The WDCAS is conceived like the adaptation of the existing engines at the level of the intake system. → A wind turbine and an air compression and storage system are added on the diesel plant. → This study demonstrates the potential of WDCAS to reduce fuel consumption and increase the efficiency of the diesel engine. → This study demonstrates that we can expect savings which can reach 50%.

  7. Design and multifidelity analysis of dual mode scramjet compression system using coupled NPSS and fluent simulation

    Science.gov (United States)

    Vijayakumar, Nandakumar

    Hypersonic airbreathing engines mark a potential future development of the aerospace industry and immense efforts have been taken in gaining knowledge in them for the past decades. The physical phenomenon occurring at the hypersonic flow regime makes the design and performance prediction of a scramjet engine hard. Though cutting-edge simulation tools fight their way toward accurate prediction of the environment, the time consumed by the entire process in designing and analyzing a scramjet engine and its component may be exorbitant. A multi-fidelity approach for designing a scramjet with a cruising Mach number of 6 is detailed in this research where high-order simulations are applied according to the physics involved in the component. Two state-of-the-art simulation tools were used to take the aerodynamic and propulsion disciplines into account for realistic prediction of the individual components as well as the entire scramjet. The specific goal of this research is to create a virtual environment to design and analyze a hypersonic, two-dimensional, planar inlet and isolator to check its operability for a dual-mode scramjet engine. The dual mode scramjet engine starts at a Mach number of 3.5 where it operates as a ramjet and accelerates to Mach 6 to be operated as a scramjet engine. The intercomponent interaction between the compression components with the rest of the engine is studied by varying the fidelity of the numerical simulation according to the complexity of the situation. Efforts have been taken to track the transition Mach number as it switches from ramjet to scramjet. A complete scramjet assembly was built using the Numerical Propulsion Simulation System (NPSS) and the performance of the engine was evaluated for various scenarios. Different numerical techniques were opted for varying the fidelity of the analysis with the highest fidelity consisting of 2D RANS CFD simulation. The interaction between the NPSS elements with the CFD solver is governed by the

  8. Energy Efficiency Evaluation and Economic Feasibility Analysis of a Geothermal Heating and Cooling System with a Vapor-Compression Chiller System

    OpenAIRE

    Imal, Muharrem; Yılmaz, Koray; Pınarbaşı, Ahmet

    2015-01-01

    Increasing attention has been given to energy utilization in Turkey. In this report, we present an energy efficiency evaluation and economic feasibility analysis of a geothermal heating and cooling system (GSHP) and a mechanical compression water chiller system (ACHP) to improve the energy utilization efficiency and reduce the primary energy demand for industrial use. Analyses of a mechanical water chiller unit, GSW 180, and geothermal heating and cooling system, EAR 431 SK, were conducted in ...

  9. Fatal pulmonary embolism subsequent to the use of Esmarch bandage and tourniquet: A case report and review of literature

    Directory of Open Access Journals (Sweden)

    Sameer Desai

    2013-01-01

    Full Text Available We report a case of fatal pulmonary embolism (PE following exsanguinations of lower limb in orthopedic surgery. A 30-year-old man was posted for fixation of a tibial plateau fracture on the seventh day after injury. Subarchnoid block was performed. Esmarch bandage was used for exsanguination of the limb and tourniquet was inflated. Within three minutes after tourniquet inflation, the patient became unconscious hypotensive, and collapsed. Resuscitation was instituted and spontaneous circulation restored. Right ventricular strain pattern on transthoracic echocardiography, increased levels of D-dimer, and Doppler examination of the lowerlimb confirmed deep venous thrombosis of right femoral vessels and PE. In spite of thrombolytic therapy with streptokinase and heparin, the patient died on the ninth day after the event. Cases of PE secondary to the use of Esmarch bandage and tourniquet are reviewed here to identify the risk groups and management of PE.

  10. System for ν-ν-coincidence spectra processing with data compression

    International Nuclear Information System (INIS)

    Byalko, A.A.; Volkov, N.G.; Tsupko-Sitnikov, V.M.; Churakov, A.K.

    1982-01-01

    Calculational algorithm and program for analyzing gamma-gamma coincidence spectra based on using the method of expansion in singular values for data compression (the SVD method) are described. Results of the testing of the program during the processing of coincidence spectrum for the low-energy region of transitions corresponding to decay 164 Lu → 164 Yb are given. The program is written in the FORTRAN language and is realized by the ES-1040 computer. The counting time constitutes about 20 min. It is concluded that the use of the SVD method permits to correct the data at the expense of distortion filtration caused with statistical deviations and random interferences, at that not distorting the initial data. The data compressed correspond more to theoretical suggestions of forms of semiconductor detector lines and two-dimensional line in the coincidence spectrum

  11. A Genuine Jahn-Teller System with Compressed Geometry and Quantum Effects Originating from Zero-Point Motion

    DEFF Research Database (Denmark)

    Aramburu, José Antonio; García-Fernández, Pablo; García Lastra, Juan Maria

    2016-01-01

    that the anomalous positive g∥ shift (g∥−g0=0.065) measured at T=20 K obeys the superposition of the |3 z2−r2⟩ and |x2−y2⟩ states driven by quantum effects associated with the zero-point motion, a mechanism first put forward by O'Brien for static Jahn–Teller systems and later extended by Ham to the dynamic Jahn...... of the calculated energy barriers for different Jahn–Teller systems allowed us to explain the origin of the compressed geometry observed for CaO:Ni+....

  12. Power plant including an exhaust gas recirculation system for injecting recirculated exhaust gases in the fuel and compressed air of a gas turbine engine

    Science.gov (United States)

    Anand, Ashok Kumar; Nagarjuna Reddy, Thirumala Reddy; Shaffer, Jason Brian; York, William David

    2014-05-13

    A power plant is provided and includes a gas turbine engine having a combustor in which compressed gas and fuel are mixed and combusted, first and second supply lines respectively coupled to the combustor and respectively configured to supply the compressed gas and the fuel to the combustor and an exhaust gas recirculation (EGR) system to re-circulate exhaust gas produced by the gas turbine engine toward the combustor. The EGR system is coupled to the first and second supply lines and configured to combine first and second portions of the re-circulated exhaust gas with the compressed gas and the fuel at the first and second supply lines, respectively.

  13. Survey for the development of compressed natural gas systems (CNG) for vehicles

    OpenAIRE

    Abulamosha, A.M.

    2005-01-01

    Compressed Natural Gas (CNG) vehicles have been used internationally by fleets for decades. The use of CNG vehicles results in less petroleum consumption, resulting in fewer air pollutants and greenhouse gas emissions in most applications. In Europe, the adoption of CNG among consumers has been slowed by the availability of affordable gasoline and diesel fuel. This investigation addresses the current situation of the CNG vehicle at the manufacturing level and the consumer level in Europe. Bas...

  14. Effects of compression injury on brain mitochondrial and tissue viability evaluated by a multiparametric monitoring system

    Science.gov (United States)

    Barbiro-Michaely, Efrat; Bachbut, Galit; Mayevsky, Avraham

    2008-02-01

    Neurosurgical procedures involve brain compression created by retractors. Although it is clear that retractors are causing damage to the brain tissue, the pathophysiology of the retraction was not investigated in details. In the present study we used the multiparametric monitoring approach for real time evaluation of mitochondrial function, hemodynamic, ionic and electrical activities monitored contralaterally to the retractor placement on the brain. The aims of the study were to test the effects of retractor size and severity of the compression on the degree of damage to the cerebral tissue. A special probe was lowered towards the cerebral cortex, (2mm and 4mm in depth) using a micromanipulator. Compression lasted for 30 minutes, than the retractor was elevated back to its initial position and monitoring continued for two hours. Additionally, two sizes of retractors were used 6mm and 3mm in diameter, the 3mm retractor included an intracranial pressure (ICP) probe. The results show that the combination of a large retractor with the depth of 4mm yielded high mortality rate (62%) of the rats while the use of a smaller retractor decreased significantly the percentage of mortality. Also, compression to the depth of 4mm increased tissue injury as compared to 2mm depth. In conclusion, the present study raises the importance and significance of multiparametric monitoring, and not only ICP and cerebral blood flow of the areas nearby the retractor position and not only the retraction site, as well as the effect of the retractor size on the damage induced to the cerebral tissue.

  15. Evaluation of thermal energy storage materials for advanced compressed air energy storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Zaloudek, F.R.; Wheeler, K.R.; Marksberry, L.

    1983-03-01

    Advanced Compressed-Air Energy Storage (ACAS) plants have the near-term potential to reduce the fuel consumption of compressed-air plants from 33 to 100%, depending upon their design. Fuel is saved by storing some or all of the heat of compression as sensible heat which is subsequently used to reheat the compressed air prior to expansion in the turbine generator. The thermal storage media required for this application must be low cost and durable. The objective of this project was to screen thermal store materials based on their thermal cycle durability, particulate formation and corrosion resistant characteristics. The materials investigated were iron oxide pellets, Denstone pebbles, cast-iron balls, and Dresser basalt rock. The study specifically addressed the problems of particle formation and thermal ratcheting of the materials during thermal cycling and the chemical attack on the materials by the high temperature and moist environment in an ACAS heat storage bed. The results indicate that from the durability standpoint Denstone, cast iron containing 27% or more chromium, and crushed Dresser basalt would possibly stand up to ACAS conditions. If costs are considered in addition to durability and performance, the crushed Dresser basalt would probably be the most desirable heat storage material for adiabatic and hybrid ACAS plants, and more in-depth longer term thermal cycling and materials testing of Dresser basalt is recommended. Also recommended is the redesign and costing analysis of both the hybrid and adiabatic ACAS facilities based upon the use of Dresser basalt as the thermal store material.

  16. Study and design of a hybrid wind-diesel-compressed air energy storage system for remote areas

    International Nuclear Information System (INIS)

    Ibrahim, H.; Younes, R.; Ilinca, A.; Dimitrova, M.; Perron, J.

    2010-01-01

    Remote areas around the world predominantly rely on diesel-powered generators for their electricity supply, a relatively expensive and inefficient technology that is responsible for the emission of 1.2 million tons of greenhouse gas (GHG) annually, only in Canada . Wind-diesel hybrid systems (WDS) with various penetration rates have been experimented to reduce diesel consumption of the generators. After having experimented wind-diesel hybrid systems (WDS) that used various penetration rates, we turned our focus to that the re-engineering of existing diesel power plants can be achieved most efficiently, in terms of cost and diesel consumption, through the introduction of high penetration wind systems combined with compressed air energy storage (CAES). This article compares the available technical alternatives to supercharge the diesel that was used in this high penetration wind-diesel system with compressed air storage (WDCAS), in order to identify the one that optimizes its cost and performances. The technical characteristics and performances of the best candidate technology are subsequently assessed at different working regimes in order to evaluate the varying effects on the system. Finally, a specific WDCAS system with diesel engine downsizing is explored. This proposed design, that requires the repowering of existing facilities, leads to heightened diesel power output, increased engine lifetime and efficiency and to the reduction of fuel consumption and GHG emissions, in addition to savings on maintenance and replacement cost.

  17. Compressed sensing of ECG signal for wireless system with new fast iterative method.

    Science.gov (United States)

    Tawfic, Israa; Kayhan, Sema

    2015-12-01

    Recent experiments in wireless body area network (WBAN) show that compressive sensing (CS) is a promising tool to compress the Electrocardiogram signal ECG signal. The performance of CS is based on algorithms use to reconstruct exactly or approximately the original signal. In this paper, we present two methods work with absence and presence of noise, these methods are Least Support Orthogonal Matching Pursuit (LS-OMP) and Least Support Denoising-Orthogonal Matching Pursuit (LSD-OMP). The algorithms achieve correct support recovery without requiring sparsity knowledge. We derive an improved restricted isometry property (RIP) based conditions over the best known results. The basic procedures are done by observational and analytical of a different Electrocardiogram signal downloaded them from PhysioBankATM. Experimental results show that significant performance in term of reconstruction quality and compression rate can be obtained by these two new proposed algorithms, and help the specialist gathering the necessary information from the patient in less time if we use Magnetic Resonance Imaging (MRI) application, or reconstructed the patient data after sending it through the network. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Technical and economic assessment of fluidized-bed-augmented compressed-air energy-storage system. Volume I. Executive summary

    Energy Technology Data Exchange (ETDEWEB)

    Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

    1981-09-01

    An energy storage system which could be attractive for future electric utility peak-load applications is a modified gas turbine power system utilizing underground storage of very high pressure air. The compressed air energy storage (CAES) concept involves using off-peak electricity generated from indigenous coal or nuclear sources to compress air, storing the air in large underground facilities, and withdrawing the air during peak-load periods when it would be heated by combustion and expanded through gas turbines to generate power. The attractiveness of the CAES concept is based upon its potential to supply competitively priced peaking energy, to reduce peak-load power plant dependence on petroleum-based fuels, and to provide a means for leveling the utility system load demand. Therefore, a technical and economic assessment of coal-fired fluidized bed (FBC) combustor/compressed air energy storage (FBC/CAES) systems was performed and is described. The conclusions drawn from the FBC/CAES study program are encouraging. They indicate that pressurized FBC/CAES power plants should be technologically feasible, provide good performance, and be economically competitive. Specifically, it is concluded that: coal-fired FBC/CAES systems should be technically feasible in the near future and potentially attractive for peak-load power generation; and an open-bed PFBC/CAES configuration would provide the best candidate for early commercialization. It has relatively low risk combined with moderate cost and reasonable round-trip heat rate. It also has the potential for future growth options which tend to reduce costs and lower fuel consumption.

  19. [Efficacy of compression knee-high socks ULCER X in treatment of venous-genesis trophic ulcers].

    Science.gov (United States)

    Bogdanets, L I; Bogachev, V Iu; Lobanov, V N; Smirnova, E S

    2013-01-01

    The study was aimed at comparatively assessing the efficacy of treatment for venous trophic ulcers at stages II-III of the wound process using special compression knee-length socks of the ULCER X kit (Sigvaris AG, St. Gallen, Switzerland) and long-stretch bandages Lauma. Compression therapy was included into the programme of outpatient treatment of forty 31-to-74-year-old patients presenting with trophic ulcers (stage II-III of the wound process) with an average area of 5,36±1,1 cm2. The Study Group consisting of 20 patients used compression knitted fabrics in the form of knee-length socks ULCER X and the comparison group (n=20) used long-stretch bandages Lauma. The obtained findings (6 months) demonstrated that using compression therapy exerted a positive effect on the process of healing of venous trophic ulcers, also proving advantages of compression therapy with the knee-length socks ULCER X that create an adequate level of pressure on the crus and maintain it in long-term daily use, reliably accelerating the healing of venous trophic ulcers as compared with elastic long-stretch bandages. The use of long-stretch elastic bandages in treatment of venous trophic ulcers turned out to be not only ineffective but fraught with a possibility of the development of various complications. During 6 months of follow up the patients using the special knee-length socks ULCER X were found to have 80 % of ulcers healed (16 patients), mainly within the first 2 months, whereas using elastic bandages resulted in only 30 % of healing (6 patients) by the end of the study. Along with it, we documented a considerable decrease in the malleolar circumference in the study group patients (from 30,05±0,78 to 28,35±0,86 cm) and in the control group from 31,2±30,35 to 30,25±0,75 cm), accompanied and followed by more than a two-fold increase in quality of life of the patients along all the parameters in the study group and a 1.4-fold increase in the control group patients.

  20. Antimicrobial Properties of Diamond-Like Carbon/Silver Nanocomposite Thin Films Deposited on Textiles: Towards Smart Bandages

    Directory of Open Access Journals (Sweden)

    Tadas Juknius

    2016-05-01

    Full Text Available In the current work, a new antibacterial bandage was proposed where diamond-like carbon with silver nanoparticle (DLC:Ag-coated synthetic silk tissue was used as a building block. The DLC:Ag structure, the dimensions of nanoparticles, the silver concentration and the silver ion release were studied systematically employing scanning electron microscopy, energy dispersive X-ray spectroscopy and atomic absorption spectroscopy, respectively. Antimicrobial properties were investigated using microbiological tests (disk diffusion method and spread-plate technique. The DLC:Ag layer was stabilized on the surface of the bandage using a thin layer of medical grade gelatin and cellulose. Four different strains of Staphylococcus aureus extracted from humans’ and animals’ infected wounds were used. It is demonstrated that the efficiency of the Ag+ ion release to the aqueous media can be increased by further RF oxygen plasma etching of the nanocomposite. It was obtained that the best antibacterial properties were demonstrated by the plasma-processed DLC:Ag layer having a 3.12 at % Ag surface concentration with the dominating linear dimensions of nanoparticles being 23.7 nm. An extra protective layer made from cellulose and gelatin with agar contributed to the accumulation and efficient release of silver ions to the aqueous media, increasing bandage antimicrobial efficiency up to 50% as compared to the single DLC:Ag layer on textile.

  1. Clinical observation on bandage type corneal contact lens applied after pterygium excision combined with fresh amniotic membrane transplantation

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2018-04-01

    Full Text Available AIM: To evaluate the clinical effect of fresh amniotic membrane transplantation in combination with bandage type corneal contact lens in the treatment of pterygium. METHODS: This study was a prospective analysis of 600 pterygium excision patients(600 cases, 600 eyesin the He Eye Hospital from January 2016 to June 2016. The patients were randomly and evenly divided into two groups: observation group and control group, 300 cases in each group(300 eyes. Observation group wore the bandage type corneal contact lens after surgery and took it down at fifth day. The control group did not. The degree of pain after surgery were evaluated at 2h, 1, 3 and 5d after surgery. The clinical outcomes in these two groups were compared in a 12mo postoperative follow-up observation. RESULTS: There were no significant differences between the observation and control group in the percentage of age and gender and size of the pterygium(P>0.05. After surgery, the degree of pain of treatment group significantly decreased compared to control group, the difference was statistically significant(PP>0.05. CONCLUSION: Bandage contact lenses could significantly release pain response after pterygium excision. But it can not reduce the recurrence rate.

  2. Antimicrobial Properties of Diamond-Like Carbon/Silver Nanocomposite Thin Films Deposited on Textiles: Towards Smart Bandages

    Science.gov (United States)

    Juknius, Tadas; Ružauskas, Modestas; Tamulevičius, Tomas; Šiugždinienė, Rita; Juknienė, Indrė; Vasiliauskas, Andrius; Jurkevičiūtė, Aušrinė; Tamulevičius, Sigitas

    2016-01-01

    In the current work, a new antibacterial bandage was proposed where diamond-like carbon with silver nanoparticle (DLC:Ag)-coated synthetic silk tissue was used as a building block. The DLC:Ag structure, the dimensions of nanoparticles, the silver concentration and the silver ion release were studied systematically employing scanning electron microscopy, energy dispersive X-ray spectroscopy and atomic absorption spectroscopy, respectively. Antimicrobial properties were investigated using microbiological tests (disk diffusion method and spread-plate technique). The DLC:Ag layer was stabilized on the surface of the bandage using a thin layer of medical grade gelatin and cellulose. Four different strains of Staphylococcus aureus extracted from humans’ and animals’ infected wounds were used. It is demonstrated that the efficiency of the Ag+ ion release to the aqueous media can be increased by further RF oxygen plasma etching of the nanocomposite. It was obtained that the best antibacterial properties were demonstrated by the plasma-processed DLC:Ag layer having a 3.12 at % Ag surface concentration with the dominating linear dimensions of nanoparticles being 23.7 nm. An extra protective layer made from cellulose and gelatin with agar contributed to the accumulation and efficient release of silver ions to the aqueous media, increasing bandage antimicrobial efficiency up to 50% as compared to the single DLC:Ag layer on textile. PMID:28773494

  3. Novel systems for the application of isolated tensile, compressive, and shearing stimulation of distraction callus tissue.

    Directory of Open Access Journals (Sweden)

    Nicholaus Meyers

    Full Text Available Distraction osteogenesis is a procedure widely used for the correction of large bone defects. However, a high complication rate persists, likely due to insufficient stability during maturation. Numerical fracture healing models predict bone regeneration under different mechanical conditions allowing fixation stiffness optimization. However, most models apply a linear elastic material law inappropriate for the transient stresses/strains present during limb lengthening or segment transport. They are also often validated using in vivo osteotomy models lacking precise mechanical regulation due to the unavoidable stimulation of secondary interfragmentary motion during ambulation under finitely stiff fixation. Therefore, in order to create a robust numerical model of distraction osteogenesis, it is necessary to both characterize the new tissue's viscoelasticity during distraction and determine the influence of strictly isolated stimulation in each loading mode (tension, compression, and shear to account for potential differences in mechanical and histological response.Two electromechanical fixators with integrated load cells were designed to precisely perform and monitor in vivo lateral distraction and isolated stimulation in sheep tibiae using a mobile, hydroxyapatite-coated titanium plate. The novel surgical procedure circumvents osteotomy, eliminating the undesirable and unquantifiable mechanical stimulation during ambulation.After a 10-day post-surgery latency period, two 0.275 mm distraction steps were performed daily for 10 days. The load cell collected data before, during, and after each distraction step and was terminated after no less than one minute from the time of distraction. A 7-day consolidation period separated the distraction phase and 18-day stimulation phase. Stimulation was carried out in isolated tension, compression, or shear while recording force/time data. Each stimulation session consisted of 120 cycles with a magnitude of

  4. Design and implementation of an integrated safety management system for compressed natural gas stations using ubiquitous sensor network

    International Nuclear Information System (INIS)

    Yang, Jae Mo; Ko, Byung Seok; Park, Chulhwan; Ko, Jae Wook; Yoo, Byungtae; Shin, Dongil

    2014-01-01

    To increase awareness of safety in facilities where hazards may exist, operators, managers, and executive officers on the site should be able to monitor such facilities. However, most compressed natural gas (CNG) service stations in Korea use only local-mode monitoring, with only on-site operators to monitor the facility. To complement this local-mode monitoring, an online safety management system called Ubiquitous-gas safety management system (U-GSMS) was developed. The U-GSMS consists largely of software and hardware. The software consists of systems that can manage safety and operations, while the hardware consists of sensors installed in the gas facility and wireless communication systems using a ubiquitous sensor network (USN) technology that facilitates communication between sensors as well as between sensors and other devices. As these systems are web-based, on-site operators as well as managers and executive officers at the headquarters can more effectively and efficiently perform monitoring and safety management

  5. Design and implementation of an integrated safety management system for compressed natural gas stations using ubiquitous sensor network

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jae Mo; Ko, Byung Seok; Park, Chulhwan; Ko, Jae Wook [Kwangwoon University, Seoul (Korea, Republic of); Yoo, Byungtae [National Disaster Management Institute, Seoul (Korea, Republic of); Shin, Dongil [Myongji University, Yongin (Korea, Republic of)

    2014-03-15

    To increase awareness of safety in facilities where hazards may exist, operators, managers, and executive officers on the site should be able to monitor such facilities. However, most compressed natural gas (CNG) service stations in Korea use only local-mode monitoring, with only on-site operators to monitor the facility. To complement this local-mode monitoring, an online safety management system called Ubiquitous-gas safety management system (U-GSMS) was developed. The U-GSMS consists largely of software and hardware. The software consists of systems that can manage safety and operations, while the hardware consists of sensors installed in the gas facility and wireless communication systems using a ubiquitous sensor network (USN) technology that facilitates communication between sensors as well as between sensors and other devices. As these systems are web-based, on-site operators as well as managers and executive officers at the headquarters can more effectively and efficiently perform monitoring and safety management.

  6. Principles for construction of control and stabilization systems for pulse energy sources on the base of compression generators

    International Nuclear Information System (INIS)

    Abdukaev, I.Kh.; Kuchinskij, V.G.; Titov, V.I.

    1984-01-01

    Principles of construction of control and stabilization systems for a compression-generator (CG)-sources of power energy pulses- are considered. CG is an electromechanical energy converter, the principle of its operation is based on magnetic flux compression with periodic change of mutual inductance of two rotating windings. In each period, with the decrease of intrinsic inductance the generator forms in the load the pulse leading edge, and in the phase rise a pulse decay. To obtain the same pulse in the following period it is neccessary that the magnetic flux initial value should be restored in the generator winding. Problems of attaining pule shaper amplitude stability are considered. The method of pulse amplitude control in the load at the expense of the change in switch moment of capacitive storage to CG windings is suggested. The block-diagram of stabilization system is presented and its operation principle is described. The control system is assembled using K 155 and K 511 microcircuits and it was tested with CG at the pulse energy to 10 kJ. The tests have shown, that already to the third pulse the system provided quite shaped series of pulses

  7. In vitro comparative analysis of resistance to compression of laboratory resin composites and a ceramic system

    Directory of Open Access Journals (Sweden)

    Montenegro Alexandre

    2010-01-01

    Full Text Available Background: Restorative materials must be capable not only of restoring the patient′s masticatory function, but also to rescue the self-esteem of those maculated by a disharmonious smile. Among the esthetic materials available on the market, the choice frequently lies between ceramic or indirect laboratory resin restorations. Aim: This study assessed the resistance to compression of two laboratory resins found on the market, namely Artglass ® and Targis ® , considering Omega 900 ® ceramic from Vita as control. Materials and Methods: With the aid of stainless steel matrices, with internal dimensions of 8.0 mm diameter at the base, 9.0 mm in the top portion and 4.0 mm height, 15 test specimens were made, being 5 of each material to be tested. The test specimens were kept in distilled water for 72 hours and submitted to an axial load by the action of a point with a rounded tip 2 mm in diameter, adapted to an EMIC 500 universal test machine. The compression speed was 0.5 mm/min, with a load cell capacity of 200 Kgf. Results: The means of the results were calculated in kilogram-force (Kgf. The results found were treated by analysis of variance (ANOVA and the differences found among the groups were identified by the Tukey test (5%. Conclusion: It was observed that the material Omega 900 ® offered significantly greater resistance to compression than the other two materials, which did not present statistically significant difference between them.

  8. A-free rigidity and applications to the compressible Euler system

    Czech Academy of Sciences Publication Activity Database

    Chiodaroli, E.; Feireisl, Eduard; Kreml, Ondřej; Wiedemann, E.

    2017-01-01

    Roč. 196, č. 4 (2017), s. 1557-1572 ISSN 0373-3114 R&D Projects: GA ČR GA13-00522S EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : A-free condition * compressible Euler equations * measure-valued solutions Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.864, year: 2016 https://link.springer.com/article/10.1007%2Fs10231-016-0629-9

  9. Real-Time Adaptive Lossless Hyperspectral Image Compression using CCSDS on Parallel GPGPU and Multicore Processor Systems

    Science.gov (United States)

    Hopson, Ben; Benkrid, Khaled; Keymeulen, Didier; Aranki, Nazeeh; Klimesh, Matt; Kiely, Aaron

    2012-01-01

    The proposed CCSDS (Consultative Committee for Space Data Systems) Lossless Hyperspectral Image Compression Algorithm was designed to facilitate a fast hardware implementation. This paper analyses that algorithm with regard to available parallelism and describes fast parallel implementations in software for GPGPU and Multicore CPU architectures. We show that careful software implementation, using hardware acceleration in the form of GPGPUs or even just multicore processors, can exceed the performance of existing hardware and software implementations by up to 11x and break the real-time barrier for the first time for a typical test application.

  10. Extensive characterisation of advanced manufacturing solutions for the ITER Central Solenoid pre-compression system

    CERN Document Server

    Langeslag, S.A.E.; Libeyre, P.; Marcinek, D.J.; Zhang, Z.

    2015-01-01

    The ITER Central Solenoid (CS), positioned in the center of the ITER tokamak, will provide a magnetic field, contributing to the confinement of the plasma. The 13 m high CS consists of a vertical stack of 6 independently driven modules, dynamically activated. Resulting opposing currents can lead to high separation forces. A pre-compression structure is implemented to counteract these opposing forces, by realising a continuous 180 MN coil-to-coil contact loading. Preload is applied by mechanical fastening via 9 subunits, positioned along the coil stack, each consisting of 2 outer and 1 inner tie plate. The tie plates therefore need to feature outstanding mechanical behaviour in a large temperature range. High strength, Nitronic®-50 type F XM-19 austenitic stainless steel is selected as candidate material. The linearised stress distribution reaches approximately 250 MPa, leading to a required yield strength of 380 MPa at room temperature. Two different manufacturing methods are being studied for the procuremen...

  11. Failure analysis of a helical compression spring for a heavy vehicle's suspension system

    Directory of Open Access Journals (Sweden)

    Youli Zhu

    2014-10-01

    Full Text Available This paper analyzed why a compression coil spring fractured at the transition position from the bearing coil to the first active coil in service, while the nominal stress here should always be much less than that at the inside coil position of a fully active coil. Visual observations indicated that a wear scar was formed on the first active coil and the fracture surface showed radiating ridges emanating from the wear scar. Scanning electron microscopy examination showed crescent shaped region and beach marks, typical of fatigue failure. ZnCaph phosphate layer and painting around the contact zone were worn out due to contact and friction and resulted in corrosion and corrosion pits induced local stress concentration. Stress analysis indicated severe stress singularities at the edges of the contact zone, which facilitated cycle slip and fatigue crack nucleation. Recommendations were also made for improving the fatigue performance of the suspension springs.

  12. A systems approach for data compression and latency reduction in cortically controlled brain machine interfaces.

    Science.gov (United States)

    Oweiss, Karim G

    2006-07-01

    This paper suggests a new approach for data compression during extracutaneous transmission of neural signals recorded by high-density microelectrode array in the cortex. The approach is based on exploiting the temporal and spatial characteristics of the neural recordings in order to strip the redundancy and infer the useful information early in the data stream. The proposed signal processing algorithms augment current filtering and amplification capability and may be a viable replacement to on chip spike detection and sorting currently employed to remedy the bandwidth limitations. Temporal processing is devised by exploiting the sparseness capabilities of the discrete wavelet transform, while spatial processing exploits the reduction in the number of physical channels through quasi-periodic eigendecomposition of the data covariance matrix. Our results demonstrate that substantial improvements are obtained in terms of lower transmission bandwidth, reduced latency and optimized processor utilization. We also demonstrate the improvements qualitatively in terms of superior denoising capabilities and higher fidelity of the obtained signals.

  13. Hydrogen Station Compression, Storage, and Dispensing Technical Status and Costs: Systems Integration

    Energy Technology Data Exchange (ETDEWEB)

    Parks, G.; Boyd, R.; Cornish, J.; Remick, R.

    2014-05-01

    At the request of the U.S. Department of Energy Fuel Cell Technologies Office (FCTO), the National Renewable Energy Laboratory commissioned an independent review of hydrogen compression, storage, and dispensing (CSD) for pipeline delivery of hydrogen and forecourt hydrogen production. The panel was asked to address the (1) cost calculation methodology, (2) current cost/technical status, (3) feasibility of achieving the FCTO's 2020 CSD levelized cost targets, and to (4) suggest research areas that will help the FCTO reach its targets. As the panel neared the completion of these tasks, it was also asked to evaluate CSD costs for the delivery of hydrogen by high-pressure tube trailer. This report details these findings.

  14. Compression ratio of municipal solid waste simulation using artificial neural network and adaptive neurofuzzy system

    Directory of Open Access Journals (Sweden)

    Maryam Mokhtari

    2014-07-01

    Full Text Available The compression ratio of Municipal Solid Waste (MSW is an essential parameter for evaluation of waste settlement. Since it is relatively time-consuming to determine compression ratio from oedometer tests and there exist difficulties associated with working on waste materials, it will be useful to develop models based on waste physical properties. Therefore, present research attempts to develop proper prediction models using ANFIS and ANN models. The compression ratio was modeled as a function of the physical properties of waste including dry unit weight, water content, and biodegradable organic content. A reliable experimental database of oedometer tests, taken from the literature, was employed to train and test the ANN and ANFIS models. The performance of the developed models was investigated according to different statistical criteria (i.e. correlation coefficient, root mean squared error, and mean absolute error recommended by researchers. The final models have demonstrated the correlation coefficients higher than 90% and low error values; so, they have capability for acceptable prediction of municipal solid waste compression ratio. Furthermore, the values of performance measures obtained for ANN and ANFIS models indicate that the ANFIS model performs better than ANN model.   Resumen El índice de compresión de residuos sólidos es un parámetro esencial para la evaluación del asentamiento de un basurero municipal. Debido al desgaste de tiempo para determinar el índice de compresión a partir de pruebas edométricas y debido a las dificultades asociadas al trabajo con materiales desechados es necesario desarrollar modelos basados en las propiedades físicas de los desechos solidos. Además, la presente investigación pretende  desarrollar modelos de predicción apropiados a partir de los esquemas ANFIS y ANN. El índice de comprensión se modeló como una función de propiedades físicas de desechos que incluyen el peso seco de una

  15. Analysis of an integrated packed bed thermal energy storage system for heat recovery in compressed air energy storage technology

    International Nuclear Information System (INIS)

    Ortega-Fernández, Iñigo; Zavattoni, Simone A.; Rodríguez-Aseguinolaza, Javier; D'Aguanno, Bruno; Barbato, Maurizio C.

    2017-01-01

    Highlights: •A packed bed TES system is proposed for heat recovery in CAES technology. •A CFD-based approach has been developed to evaluate the behaviour of the TES unit. •TES system enhancement and improvement alternatives are also demonstrated. •TES performance evaluated according to the first and second law of thermodynamics. -- Abstract: Compressed air energy storage (CAES) represents a very attracting option to grid electric energy storage. Although this technology is mature and well established, its overall electricity-to-electricity cycle efficiency is lower with respect to other alternatives such as pumped hydroelectric energy storage. A meager heat management strategy in the CAES technology is among the main reasons of this gap of efficiency. In current CAES plants, during the compression stage, a large amount of thermal energy is produced and wasted. On the other hand, during the electricity generation stage, an extensive heat supply is required, currently provided by burning natural gas. In this work, the coupling of both CAES stages through a thermal energy storage (TES) unit is introduced as an effective solution to achieve a noticeable increase of the overall CAES cycle efficiency. In this frame, the thermal energy produced in the compression stage is stored in a TES unit for its subsequent deployment during the expansion stage, realizing an Adiabatic-CAES plant. The present study addresses the conceptual design of a TES system based on a packed bed of gravel to be integrated in an Adiabatic-CAES plant. With this objective, a complete thermo-fluid dynamics model has been developed, including the implications derived from the TES operating under variable-pressure conditions. The formulation and treatment of the high pressure conditions were found being particularly relevant issues. Finally, the model provided a detailed performance and efficiency analysis of the TES system under charge/discharge cyclic conditions including a realistic operative

  16. Comparative evaluation of Comfilcon A and Senofilcon A bandage contact lenses after transepithelial photorefractive keratectomy.

    Science.gov (United States)

    Mukherjee, Achyut; Ioannides, Antonis; Aslanides, Ioannis

    2015-01-01

    To evaluate and compare Comfilcon A and Senofilcon A silicone hydrogel contact lenses used as a therapeutic bandage following transepithelial excimer laser photorefractive keratectomy (PRK). Patients undergoing transepithelial PRK for myopia were prospectively recruited. Included patients had a Comfilcon A silicone hydrogel lens inserted in one eye, with a Senofilcon A lens in the contralateral eye. Postoperative assessment of subjective pain, epithelial healing and visual recovery was at day 1, 3 and 7. Contact lens factors including centration, movement and deposits were assessed. 48 eyes of 24 patients were included in the study. Mean age was 31 years (SD 11) and mean refractive error -4.5 D (SD 1.8). Mean pain score at day 1 was significantly higher in the Comfilcon group at 4.6 (SD 2.7) vs. 1.5 (SD2.5) in the Senofilcon group (P<0.005). Mean time to healing was 3.17 days (SD 0.37) in the Comfilcon group, and 3.21 days (SD 0.4) in the Senofilcon group, with no difference in defect size. There was a pronounced central raphe in 1 eye in the Comfilcon group vs. 5 eyes in the Senofilcon group (P=0.19). Significantly more eyes demonstrated no lens movement in the Senofilcon group (18 vs. 4, P=0.0001). The variation in material characteristics and lens geometry of different silicone hydrogel lenses affects their clinical characteristics in therapeutic roles. Other factors than oxygen permeability may affect pain and epithelial healing, with superior pain relief from the less permeable Senofilcon lens in this study. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Excess molar volumes and isentropic compressibility of binary systems {trioctylmethylammonium bis(trifluoromethysulfonyl)imide + methanol or ethanol or 1-propanol} at different temperatures

    International Nuclear Information System (INIS)

    Sibiya, P.N.; Deenadayalu, N.

    2008-01-01

    This paper reports measurements of densities for the binary systems of an ionic liquid and an alkanol at T = (298.15, 303.15, and 313.15) K. The IL is trioctylmethylammonium bis(trifluoromethylsulfonyl)imide [OMA] + [Tf 2 N] - and the alkanols are methanol, or ethanol, or 1-propanol. The speed of sound at T = 298.15 K for the same binary systems was also measured. The excess molar volumes and the isentropic compressibilities for the above systems were then calculated from the experimental densities and the speed of sound, respectively. Redlich-Kister smoothing polynomial equation was used to fit the excess molar volume and the deviation in isentropic compressibility data. The partial molar volumes were determined from the Redlich-Kister coefficients. For all the systems studied, the excess molar volumes have both negative and positive values, while the deviations in isentropic compressibility are negative over the entire composition range

  18. Online remote control systems for static and dynamic compression and decompression using diamond anvil cells

    International Nuclear Information System (INIS)

    Sinogeikin, Stanislav V.; Smith, Jesse S.; Rod, Eric; Lin, Chuanlong; Kenney-Benson, Curtis; Shen, Guoyin

    2015-01-01

    The ability to remotely control pressure in diamond anvil cells (DACs) in accurate and consistent manner at room temperature, as well as at cryogenic and elevated temperatures, is crucial for effective and reliable operation of a high-pressure synchrotron facility such as High Pressure Collaborative Access Team (HPCAT). Over the last several years, a considerable effort has been made to develop instrumentation for remote and automated pressure control in DACs during synchrotron experiments. We have designed and implemented an array of modular pneumatic (double-diaphragm), mechanical (gearboxes), and piezoelectric devices and their combinations for controlling pressure and compression/decompression rate at various temperature conditions from 4 K in cryostats to several thousand Kelvin in laser-heated DACs. Because HPCAT is a user facility and diamond cells for user experiments are typically provided by users, our development effort has been focused on creating different loading mechanisms and frames for a variety of existing and commonly used diamond cells rather than designing specialized or dedicated diamond cells with various drives. In this paper, we review the available instrumentation for remote static and dynamic pressure control in DACs and show some examples of their applications to high pressure research

  19. Developing an early alert system for metastatic spinal cord compression (MSCC): Red Flag credit cards.

    Science.gov (United States)

    Turnpenney, Jackie; Greenhalgh, Sue; Richards, Lena; Crabtree, Annamaria; Selfe, James

    2015-01-01

    To produce a user-friendly list of metastatic spinal cord compression (MSCC) Red Flags for non-specialist 'generalist' front-line clinicians working in primary-care settings. The issue of identifying MSCC early to prevent serious long-term disability was a key theme identified by the Task and Finish Group at Greater Manchester and Cheshire Cancer Network (GMCCN) in 2009. It was this group who initially brokered and then coordinated the current development as part of their strategic approach to improving care for MSCC patients. A consensus-building approach that considered the essential minimum data requirements to raise the index of suspicion suggestive of MSCC was adopted. This followed a model of cross-boundary working to facilitate the mutual sharing of expertise across a variety of relevant clinical specialisms. A guideline aimed at helping clinicians to identify the early signs and symptoms of MSCC was produced in the form of a credit card. This credit card includes key statements about MSCC, signposting to key sources of additional information and a user-friendly list of Red Flags which has been developed into an eight-item Red Flag mnemonic. To date, an excess of 120,000 cards have been printed by a variety of organisations and the distribution of the cards is ongoing across the United Kingdom and the Republic of Ireland.

  20. Effect of a stent bandage on the likelihood of incisional infection following exploratory coeliotomy for colic in horses

    DEFF Research Database (Denmark)

    Tnibar, Aziz; Grubbe Lin, Kathrine; Nielsen, Katrine Thurøe

    2013-01-01

    criteria were animals that had one ventral midline coeliotomy and had survived at least 10 days after surgery. Horses were categorised into 2 groups:no-stent group and stent group. The following data were collected for each case: age, sex, weight, heart rate, packed cell volume, primary lesion, performance...... of an enterotomy or intestinal resection, surgical classification, use of local antimicrobials, duration of surgery, intra-abdominal administration of sodium carboxymethylcellulose, intravenous administration of lidocaine, surgeon, use of a stent bandage, duration of stent use, and use of a belly band. Factors...

  1. Sistemas distribuídos aplicados à compressão e recuperação de imagens = Distributed systems applied to image compression and recovery

    Directory of Open Access Journals (Sweden)

    Fabio Jorge Assad Gostaldon

    2008-01-01

    Full Text Available Processamento digital de imagens é uma área que demanda grande capacidade de processamento. Sob este fato, torna-se interessante a implementação de softwares que estejam baseados na distribuição do processamento em vários nós ou máquinas da rede de computadores. Especificamente neste trabalho são abordados algoritmos distribuídos de compressão e expansão de imagens que utilizam a imagem transformada discreta de cosseno. Os resultados mostram que a economia de tempo conseguida com os algoritmos paralelos, em relação aos seus equivalentes seqüenciais, é função da resolução da imagem eda complexidade dos cálculos envolvidos, ou seja, maior a eficiência quanto maior o tempo de processamento em relação ao tempo de comunicação entre os nós.Digital image processing is a field that demands great processing capacity. As such, it becomes relevant to implement software that is based on the distribution of the processing into several nodes divided by computers belonging to the same network. Specificallydiscussed in this work are distributed algorithms of compression and expansion of images using the discrete cosine transform. The results show that the savings in processing time obtained due to the parallel algorithms, in comparison to its sequential equivalents, is afunction that depends on the resolution of the image and the complexity of the involved calculation; that is, efficiency is greater the longer the processing period is in terms of thetime involved for the communication between the network points.

  2. Sensitivity analysis for the energy performance assessment of hybrid compressed air energy storage systems

    International Nuclear Information System (INIS)

    Briola, Stefano; Di Marco, Paolo; Gabbrielli, Roberto; Riccardi, Juri

    2017-01-01

    Highlights: •A sensitivity analysis and DOE of the complete hybrid CAES are carried out. •The influence of the storage site volume on performance indicators is negligible. •The performances increase with the decrease of the compressor outlet pressure. •The performances are correlated for each temperature increase in combustion chamber. •Hybridization of Huntorf implies a significant increase of its first law efficiency. -- Abstract: A detailed mathematical model was developed for the complete Hybrid Compressed Air Energy Storage (H-CAES) configuration with underground storage site and liquid thermal energy storage, operating with a sequence of processes (charging, holding and discharging with respective duration) in arbitrary order. A sensitivity analysis was carried out in order to calculate several performance indicators of the complete H-CAES configuration, in relation to the simultaneous change of several process parameters. The methodology “Design of Experiments” was applied to the results of the sensitivity analysis in order to calculate the main effects of each process parameter on each performance indicator. The influence of the storage site volume on each performance indicator is negligible. The reduction of the compressor group outlet pressure and of the turbine group power allows a more effective thermodynamic utilization both of the energy stored by the compressors and of the overall energy supplied to the plant. Furthermore, the former utilization is more effective by an increase of the gas temperature in the combustion chambers, whereas the latter utilization is worsened. Moreover, as case study, the existing diabatic CAES plant of Huntorf was modified by introducing a diathermic oil thermal storage. This plant is suitable to operate according to a partial hybrid configuration by the deactivation of the heat exchanger located upstream of the low pressure turbine. The thermodynamic utilization of the overall energy supplied to the plant

  3. Comparative data compression techniques and multi-compression results

    International Nuclear Information System (INIS)

    Hasan, M R; Ibrahimy, M I; Motakabber, S M A; Ferdaus, M M; Khan, M N H

    2013-01-01

    Data compression is very necessary in business data processing, because of the cost savings that it offers and the large volume of data manipulated in many business applications. It is a method or system for transmitting a digital image (i.e., an array of pixels) from a digital data source to a digital data receiver. More the size of the data be smaller, it provides better transmission speed and saves time. In this communication, we always want to transmit data efficiently and noise freely. This paper will provide some compression techniques for lossless text type data compression and comparative result of multiple and single compression, that will help to find out better compression output and to develop compression algorithms

  4. Vapor Compression Refrigeration System for Cold Storage on Spacecrafts, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA is looking for a high efficiency long term food storage system for space crafts. Previous refrigerator/freezer systems developed for this application such as...

  5. A comparative study of compression-expansion type dehumidification systems to achieve low dew point air

    International Nuclear Information System (INIS)

    Moon, Choon; Bansal, Pradeep

    2009-01-01

    This paper presents a theoretical feasibility study of three dehumidification systems to achieve air with dew points down to (-) 40 deg. C. The systems consist of compressors, heat exchangers, expanders and heaters. A thermodynamic model has been developed of the systems to study the effect of the compressor, expander, and heat recovery heat exchanger efficiency as a function of pressure ratio, net required work, quantity of condensed moisture, and system outlet dew point temperature. The analysis has revealed that the selection of a heat recovery heat exchanger is critical for an efficient dehumidification system, where compressor efficiency has the dominant effect on power consumption.

  6. Progress and monitoring system on compression and transmission technologies of dynamic image

    International Nuclear Information System (INIS)

    Kobayashi, Hiroyuki; Saijo, Nobuyuki; Nakajo, Ken

    2001-01-01

    The Toshiba Corporation developed a real-time dynamic image transmission matched with quality of transmission circuit by using MPEG-4 which was recent international standard system for the dynamic image coding system. Concretely, this system made possible on real-time dynamic image transmission even at transmission on wireless circuit such as portable telephone, PHS, wireless LAN, and so on, at viewpoint of the mobile communication. And, by using the wireless circuit, it could be built without any limit of transmission cable, to realize its layout-free establishment. In addition, this system uses only image for communication without using voice, and some devices were carried out to upgrade image and frame speed as possible. Here were described on outlines of transmission system and principle of detection MPEG-4, and function and application of monitoring system using this system. (G.K.)

  7. Compressive sensing in medical imaging.

    Science.gov (United States)

    Graff, Christian G; Sidky, Emil Y

    2015-03-10

    The promise of compressive sensing, exploitation of compressibility to achieve high quality image reconstructions with less data, has attracted a great deal of attention in the medical imaging community. At the Compressed Sensing Incubator meeting held in April 2014 at OSA Headquarters in Washington, DC, presentations were given summarizing some of the research efforts ongoing in compressive sensing for x-ray computed tomography and magnetic resonance imaging systems. This article provides an expanded version of these presentations. Sparsity-exploiting reconstruction algorithms that have gained popularity in the medical imaging community are studied, and examples of clinical applications that could benefit from compressive sensing ideas are provided. The current and potential future impact of compressive sensing on the medical imaging field is discussed.

  8. Clinical study of two kinds of bandage contact lenses after laser-assisted subepithelial keratectomy

    Directory of Open Access Journals (Sweden)

    Wan-Ting Zhang

    2016-07-01

    Full Text Available AIM: To investigate the clinical safety and effectiveness of the two kind of bandage contact lenses: Senofilcon A(Johnson & Johnson Acuvue Oasysand Balafilcon A(Bausch& Lomb pure visionafter laser-assisted subepithelial keratectomy(LASEK. METHODS: Thirty-eight patients(76 eyeswho had undergone the LASEK were divided into two groups. One group of patients wore Balafilcon A, the other group of patients fitted with Senofilcon A. The lenses were worn continuously for 7d. This was a seven-day experience and the patients scored for the symptom of the eyes(sore eyes, foreign body sensation and tearingon the third day and the seventh day. Both of the two groups of patients taken off the soft contact lens on the seventh day and let their vision and corneal staining checked.RESULTS: The symptoms of eye sore and tearing of the two groups patients were different. The patients who wore the Senofilcon A were better. The pain of eyes were also different at 3 and 7d after surgeries(Z=-4.146, P=0.000; Z=-2.814, P=0.005. The difference on tearing between the two groups at 3 and 7d after surgeries were significant(Z=-2.309, P=0.021; Z=-3.276, P=0.001. There was no difference on sensation of dryness between the two groups at 3 and 7d after surgeries(Z=-0.447, P=0.655; Z=-0.966, P=0.334. After the lenses were taken off, the visual acuity of patients wearing Senofilcon A was better(t=3.800, P=0.001; corneal staining showed limited spots in 1-2 quadrants with significant difference(Z=-2.384,P=0.017. CONCLUSION: The Senofilcon A(Johnson & Johnson Acuvue Oasysand Balafilcon A(Bausch& Lomb pure visionbandage contact lenses are safe and effective after LASEK, and the former is better than the latter in epithelial regeneration.

  9. Cardiac implantable electronic device hematomas: Risk factors and effect of prophylactic pressure bandaging.

    Science.gov (United States)

    Koh, Youlin; Bingham, Nicholas E; Law, Natalie; Le, Dustin; Mariani, Justin A

    2017-07-01

    Cardiac implantable electronic device (CIED) hematomas are associated with many adverse outcomes. We examined the incidence and risk factors associated with hematoma formation post-CIED implantation, and explored the preventative effect of prophylactic pressure bandaging (PPB) in a large tertiary center. 1,091 devices were implanted during October 2011-December 2014. Clinically significant hematomas (CSH) were those that necessitated prolonged admission, including those due to reoperation, and clinically suspicious hematomas were swellings noted by medical/nursing staff. We screened for variables affecting hematoma incidence prior to conducting multivariate logistic regression analyses, one for all hematomas and one for CSH. 61 hematomas were identified (5.6% of patients), with 12 of those clinically significant (1.1% of patients). Factors significantly increasing the odds of developing any hematoma were stage 2 (odds ratio [OR] = 2.93, 95% confidence interval [CI] [1.08-7.94], P = 0.034) and 3 chronic kidney disease (CKD) (OR = 3.39 [1.20-9.56], P = 0.021), unfractionated heparin/therapeutic enoxaparin (OR = 3.15 [1.22-8.14], P = 0.018), and dual antiplatelets-aspirin + clopidogrel (OR = 2.95 [1.14-7.65], P = 0.026) + other combinations. Body Mass index (BMI) 25.0-29.9 (OR 0.52 [0.28-0.98], P = 0.044) and >30 were associated with decreased hematoma risk (OR 0.43 [0.20-0.91], P = 0.028). Factors significant for CSH formation were unfractionated heparin/therapeutic enoxaparin (OR = 9.55 [1.83-49.84], P = 0.007) and aspirin + clopidogrel (OR = 7.19 [1.01-50.91], P = 0.048). PPB nonsignificantly increased the odds of total hematoma development (OR = 1.53 [0.87-2.69], P = 0.135), and reduced CSH (OR = 0.67 [0.18-2.47], P = 0.547). Heparin and dual antiplatelet use remain strong predictors of overall hematoma formation. CKD is a comparatively moderate predictor. BMI > 25 may decrease the risk of hematoma formation. PPB had nonsignificant effects on hematoma development

  10. System behaviour of compressed-air energy-storage in Denmark with a high penetration of renewable energy sources

    International Nuclear Information System (INIS)

    Salgi, Georges; Lund, Henrik

    2008-01-01

    In 2005, wind power supplied 19% of the 36 TWh annual electricity demand in Denmark, while 50% was produced at combined heat-and-power plants (CHP). The installed wind-turbine capacity in Western Denmark exceeds the local demand at certain points in time. So far, excess production has been exported to neighbouring countries. However, plans to expand wind power both in Denmark and in its neighbouring countries could restrain the export option and create transmission congestion challenges. This results in a need to increase the flexibility of the local electricity-system. Compressed-Air Energy-Storage (CAES) has been proposed as a potential solution for levelling fluctuating wind-power production and maintaining a system balance. This paper analyses the energy-balance effects of adding CAES to the Western Danish energy-system. Results show that even with an unlimited CAES plant capacity, excess power production is not eliminated because of the high percentage of CHP production. The optimal wind-power penetration for maximum CAES operation is found to be around 55%. The minimum storage size for CAES to fully eliminate condensing power plants operation in the optimized system is over 500 GWh, which corresponds to a cavern volume of around 234 Mm 3 at an average pressure of 60 bar. Such a storage size would be technically and economically unfeasible. The analysis, however, did not include the potential role of a CAES plant in regulating the power services. (author)

  11. Compressing interpreted satellite imagery for geographic information systems applications over extensive regions

    Science.gov (United States)

    Miller, Stephan W.

    1981-01-01

    Image processing systems (IPS) and techniques effectively transform satellite imagery into data for input into a spatial database. Geographic information systems (GIS), consisting of graphic input and spatial database management subsystems, are capable of processing digital map and map overlay data to build and manipulate a spatial database. These systems can be successfully integrated to create a successful spatial data handling capability provided certain obstacle are understood and overcome.

  12. An Online System for Remote SHM Operation with Content Adaptive Signal Compression

    OpenAIRE

    Westerkamp , Clemens; Hennewig , Alexander; Speckmann , Holger; Bisle , Wolfgang; Colin , Nicolas; Rafrafi , Mona

    2014-01-01

    International audience; Remote engineering systems are valuable tools to give visual assistance and remote support e.g. in NDT (Non-destructive Testing) or SHM (Structural Health Monitoring). They allow discussing a second opinion with a remote expert and thus reducing the human factor during testing and monitoring. For an optimal impression of the situation, the second person requires both a camera view of the location and the screen view of the system used. The OMA system (Online Maintenanc...

  13. Framework for Combined Diagnostics, Prognostics and Optimal Operation of a Subsea Gas Compression System

    OpenAIRE

    Verheyleweghen, Adriaen; Jaeschke, Johannes

    2017-01-01

    The efficient and safe operation of subsea gas and oil production systems sets strict requirements to equipment reliability to avoid unplanned breakdowns and costly maintenance interventions. Because of this, condition monitoring is employed to assess the status of the system in real-time. However, the condition of the system is usually not considered explicitly when finding the optimal operation strategy. Instead, operational constraints on flow rates, pressures etc., based on worst-case sce...

  14. Data compression/error correction digital test system. Appendix 2: Theory of operation

    Science.gov (United States)

    1972-01-01

    An overall block diagram of the DC/EC digital system test is shown. The system is divided into two major units: the transmitter and the receiver. In operation, the transmitter and receiver are connected only by a real or simulated transmission link. The system inputs consist of: (1) standard format TV video, (2) two channels of analog voice, and (3) one serial PCM bit stream.

  15. Integration of phase change materials in compressed hydrogen gas systems: Modelling and parametric analysis

    DEFF Research Database (Denmark)

    Mazzucco, Andrea; Rothuizen, Erasmus; Jørgensen, Jens-Erik

    2016-01-01

    to the phase change material, mainly occurs after the fueling is completed, resulting in a hydrogen peak temperature higher than 85 C and a lower fueled mass than a gas-cooled system. Such a mass reduction accounts for 12% with respect to the case of a standard tank system fueled at 40 C. A parametric analysis...

  16. Experimental Validation of the Simulation Model of a DOAS Equipped with a Desiccant Wheel and a Vapor Compression Refrigeration System

    Directory of Open Access Journals (Sweden)

    Pedro J. Martínez

    2017-09-01

    Full Text Available A dedicated outdoor air system (DOAS can be designed to supply 100% of the outside air and meet the latent load of the room with dry air. The objectives of this study were to develop a model of a DOAS equipped with a desiccant wheel and a vapor-compression refrigeration system, build a prototype, validate the model with experimental data, and gain knowledge about the system operation. The test facility was designed with the desiccant wheel downstream of the cooling coil to take advantage of the operating principles of cooling coils and desiccants. A model of the DOAS was developed in the TRNSYS environment. The root mean standard error (RMSE was used for model validation by comparing the measured air and refrigerant properties with the corresponding calculated values. The results obtained with the developed model showed that the DOAS was able to maintain an indoor humidity ratio depending on outdoor conditions. Laboratory tests were also used to investigate the effect of changes in the regeneration air temperature and the process airflow rate on the process air humidity ratio at the outlet of the wheel. The results are consistent with the technical literature.

  17. Fault diagnosis and refrigerant leak detection in vapour compression refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Tassou, S.A.; Grace, I.N. [Brunel University, Uxbridge (United Kingdom). Department of Mechanical Engineering

    2005-08-01

    The environmental impact of refrigeration systems can be reduced by operation at higher efficiency and reduction of refrigerant leakage. Refrigerant loss contributes both directly and indirectly to global warming through inefficient system operation, increased power consumption and greenhouse gas emissions and higher maintenance costs. Existing sensor-based leak detection methods are limited by the inability to detect gradual leakage and the need for careful sensor location. There is a requirement for a real-time performance monitoring approach to leak detection and fault diagnosis which overcomes these disadvantages. This paper reports on the development of a fault diagnosis and refrigerant leak detection system based on artificial intelligence and real-time performance monitoring. The system has been used successfully to distinguish between faulty and fault free operation, steady-state and transient operation, leakage and over charge conditions. Work currently underway is aimed at testing additional fault conditions and establishing further rules to distinguish between these patterns. (author)

  18. Energy Efficiency Evaluation and Economic Feasibility Analysis of a Geothermal Heating and Cooling System with a Vapor-Compression Chiller System

    Directory of Open Access Journals (Sweden)

    Muharrem Imal

    2015-09-01

    Full Text Available Increasing attention has been given to energy utilization in Turkey. In this report, we present an energy efficiency evaluation and economic feasibility analysis of a geothermal heating and cooling system (GSHP and a mechanical compression water chiller system (ACHP to improve the energy utilization efficiency and reduce the primary energy demand for industrial use. Analyses of a mechanical water chiller unit, GSW 180, and geothermal heating and cooling system, EAR 431 SK, were conducted in experimental working areas of the office buildings in a cigarette factory in Mersin, Turkey. The heating and cooling loads of the cigarette factory building were calculated, and actual thermal data were collected and analyzed. To calculate these loads, the cooling load temperature difference method was used. It was concluded that the geothermal heating and cooling system was more useful and productive and provides substantial economic benefits.

  19. Technical Assessment of Cryo-Compressed Hydrogen Storage Tank Systems for Automotive Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ahluwalia, Rajesh [Argonne National Lab. (ANL), Argonne, IL (United States); Hua, T. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Peng, J. -K. [Argonne National Lab. (ANL), Argonne, IL (United States); Lasher, S. [TIAX LLC, Lexington, MA (United States); McKenney, Kurtis [TIAX LLC, Lexington, MA (United States); Sinha, J. [TIAX LLC, Lexington, MA (United States)

    2009-12-01

    Technical report describing DOE's second assessment report on a third generation (Gen3) system capable of storing hydrogen at cryogenic temperatures within a pressure vessel on-board a vehicle. The report includes an overview of technical progress to date, including the potential to meet DOE onboard storage targets, as well as independent reviews of system cost and energy analyses of the technology paired with delivery costs.

  20. Development of High-Efficiency Low-Lift Vapor Compression System - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas; Armstrong, Peter; Wang, Weimin; Fernandez, Nicholas; Cho, Heejin; Goetzler, W.; Burgos, J.; Radhakrishnan, R.; Ahlfeldt, C.

    2010-03-31

    PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.

  1. Vapor compression heat pump system field tests at the tech complex

    Science.gov (United States)

    Baxter, Van D.

    1985-11-01

    The Tennessee Energy Conservation In Housing (TECH) complex has been utilized since 1977 as a field test site for several novel and conventional heat pump systems for space conditioning and water heating. Systems tested include the Annual Cycle Energy System (ACES), solar assisted heat pumps (SAHP) both parallel and series, two conventional air-to-air heat pumps, an air-to-air heat pump with desuperheater water heater, and horizontal coil and multiple shallow vertical coil ground-coupled heat pumps (GCHP). A direct comparison of the measured annual performance of the test systems was not possible. However, a cursory examination revealed that the ACES had the best performance, however, its high cost makes it unlikely that it will achieve wide-spread use. Costs for the SAHP systems are similar to those of the ACES but their performance is not as good. Integration of water heating and space conditioning functions with a desuperheater yielded significant efficiency improvement at modest cost. The GCHP systems performed much better for heating than for cooling and may well be the most efficient alternative for residences in cold climates.

  2. Open air-vapor compression refrigeration system for air conditioning and hot water cooled by cool water

    International Nuclear Information System (INIS)

    Hou Shaobo; Li Huacong; Zhang Hefei

    2007-01-01

    This paper presents an open air-vapor compression refrigeration system for air conditioning and hot water cooled by cool water and proves its feasibility through performance simulation. Pinch technology is used in analysis of heat exchange in the surface heat exchanger, and the temperature difference at the pinch point is selected as 6 o C. Its refrigeration depends mainly on both air and vapor, more efficient than a conventional air cycle, and the use of turbo-machinery makes this possible. This system could use the cool in the cool water, which could not be used to cool air directly. Also, the heat rejected from this system could be used to heat cool water to 33-40 o C. The sensitivity analysis of COP to η c and η t and the simulated results T 4 , T 7 , T 8 , q 1 , q 2 and W m of the cycle are given. The simulations show that the COP of this system depends mainly on T 7 , η c and η t and varies with T 3 or T wet and that this cycle is feasible in some regions, although the COP is sensitive to the efficiencies of the axial compressor and turbine. The optimum pressure ratio in this system could be lower, and this results in a fewer number of stages of the axial compressor. Adjusting the rotation speed of the axial compressor can easily control the pressure ratio, mass flow rate and the refrigerating capacity. The adoption of this cycle will make the air conditioned room more comfortable and reduce the initial investment cost because of the obtained very low temperature air. Humid air is a perfect working fluid for central air conditioning and no cost to the user. The system is more efficient because of using cool water to cool the air before the turbine. In addition, pinch technology is a good method to analyze the wet air heat exchange with water

  3. Utilization of waste heat from a HCCI (homogeneous charge compression ignition) engine in a tri-generation system

    International Nuclear Information System (INIS)

    Sarabchi, N.; Khoshbakhti Saray, R.; Mahmoudi, S.M.S.

    2013-01-01

    The waste heat from exhaust gases and cooling water of Homogeneous charge compression ignition engines (HCCI) are utilized to drive an ammonia-water cogeneration cycle (AWCC) and some heating processes, respectively. The AWCC is a combination of the Rankine cycle and an absorption refrigeration cycle. Considering the chemical kinetic calculations, a single zone combustion model is developed to simulate the natural gas fueled HCCI engine. Also, the performance of AWCC is simulated using the Engineering Equation Solver software (EES). Through combining these two codes, a detailed thermodynamic analysis is performed for the proposed tri-generation system and the effects of some main parameters on the performances of both the AWCC and the tri-generation system are investigated in detail. The cycle performance is then optimized for the fuel energy saving ratio (FESR). The enhancement in the FESR could be up to 28.56%. Under optimized condition, the second law efficiency of proposed system is 5.19% higher than that of the HCCI engine while the reduction in CO 2 emission is 4.067% as compared with the conventional separate thermodynamic systems. Moreover, the results indicate that the engine, in the tri-generation system and the absorber, in the bottoming cycle has the most contribution in exergy destruction. - Highlights: • A new thermodynamic tri-generation system is proposed for waste heat recovery of HCCI engine. • A single zone combustion model is developed to simulate the natural gas fueled HCCI engine. • The proposed tri-generation cycle is analyzed from the view points of both first and second laws of thermodynamics. • In the considered cycle, enhancements of 28.56% in fuel energy saving ratio and 5.19% in exergy efficiency are achieved

  4. The Ansel Adams zone system: HDR capture and range compression by chemical processing

    Science.gov (United States)

    McCann, John J.

    2010-02-01

    We tend to think of digital imaging and the tools of PhotoshopTM as a new phenomenon in imaging. We are also familiar with multiple-exposure HDR techniques intended to capture a wider range of scene information, than conventional film photography. We know about tone-scale adjustments to make better pictures. We tend to think of everyday, consumer, silver-halide photography as a fixed window of scene capture with a limited, standard range of response. This description of photography is certainly true, between 1950 and 2000, for instant films and negatives processed at the drugstore. These systems had fixed dynamic range and fixed tone-scale response to light. All pixels in the film have the same response to light, so the same light exposure from different pixels was rendered as the same film density. Ansel Adams, along with Fred Archer, formulated the Zone System, staring in 1940. It was earlier than the trillions of consumer photos in the second half of the 20th century, yet it was much more sophisticated than today's digital techniques. This talk will describe the chemical mechanisms of the zone system in the parlance of digital image processing. It will describe the Zone System's chemical techniques for image synthesis. It also discusses dodging and burning techniques to fit the HDR scene into the LDR print. Although current HDR imaging shares some of the Zone System's achievements, it usually does not achieve all of them.

  5. The inverse of the divergence operator on perforated domains with applications to homogenization problems for the compressible Navier–Stokes system

    Czech Academy of Sciences Publication Activity Database

    Diening, L.; Feireisl, Eduard; Lu, Y.

    2017-01-01

    Roč. 23, č. 3 (2017), s. 851-868 ISSN 1292-8119 Keywords : perforated domains * Bogovskii type operators * homogenization * compressible Navier–Stokes system Subject RIV: BA - General Mathematics OBOR OECD: Applied mathematics Impact factor: 1.540, year: 2016 https://www.esaim-cocv.org/articles/cocv/abs/2017/03/cocv160016-s/cocv160016-s.html

  6. A compressed hydrogen gas storage system with an integrated phase change material

    DEFF Research Database (Denmark)

    Mazzucco, Andrea; Rothuizen, Erasmus Damgaard; Jørgensen, Jens Erik

    2015-01-01

    below the critical temperature of 85 °C, while filling the hydrogen at ambient temperature. Results show that a 10-mm-thick layer of paraffin wax can absorb enough heat to reduce the adiabatic temperature by 20 K when compared to a standard Type IV tank. The heat transfer from the gas to the phase...... change material, mainly occurs after the fueling is completed, resulting in a higher hydrogen peak temperature inside the tank and a lower fuelled mass than a gas-cooled system. Such a mass reduction accounts for 12% with respect to the case of a standard tank system fuelled at -40 °C....

  7. Evolution of the Orszag-Tang vortex system in a compressible medium. II - Supersonic flow

    Science.gov (United States)

    Picone, J. Michael; Dahlburg, Russell B.

    1991-01-01

    A study is presented on the effect of embedded supersonic flows and the resulting emerging shock waves on phenomena associated with MHD turbulence, including reconnection, the formation of current sheets and vortex structures, and the evolution of spatial and temporal correlations among physical variables. A two-dimensional model problem, the Orszag-Tang (1979) vortex system, is chosen, which involves decay from nonrandom initial conditions. The system is doubly periodic, and the initial conditions consist of single-mode solenoidal velocity and magnetic fields, each containing X points and O points. The initial mass density is flat, and the initial pressure fluctuations are incompressible, balancing the local forces for a magnetofluid of unit mass density. Results on the evolution of the local structure of the flow field, the global properties of the system, and spectral correlations are presented. The important dynamical properties and observational consequences of embedded supersonic regions and emerging shocks in the Orszag-Tang model of an MHD system undergoing reconnection are discussed. Conclusions are drawn regarding the effects of local supersonic regions on MHD turbulence.

  8. Control System Development for Power Generation from Small-Scale Compressed Air Energy Storage

    Science.gov (United States)

    2017-06-01

    35  Figure 26  Control Program Flowchart ...Figure 26 Control Program Flowchart 1. Resetting Variables The Micro850 has internal memory that stores the last state of variables when power is...Research, Energy Systems Technology Evaluation Program (ESTEP), under the technical monitoring of Stacey Curtis, Marissa Brand and Richard Carlin 10

  9. Dual-wavelength OR-PAM with compressed sensing for cell tracking in a 3D cell culture system

    Science.gov (United States)

    Huang, Rou-Xuan; Fu, Ying; Liu, Wang; Ma, Yu-Ting; Hsieh, Bao-Yu; Chen, Shu-Ching; Sun, Mingjian; Li, Pai-Chi

    2018-02-01

    Monitoring dynamic interactions of T cells migrating toward tumor is beneficial to understand how cancer immunotherapy works. Optical-resolution photoacoustic microscope (OR-PAM) can provide not only high spatial resolution but also deeper penetration than conventional optical microscopy. With the aid of exogenous contrast agents, the dual-wavelength OR-PAM can be applied to map the distribution of CD8+ cytotoxic T lymphocytes (CTLs) with gold nanospheres (AuNS) under 523nm laser irradiation and Hepta1-6 tumor spheres with indocyanine green (ICG) under 800nm irradiation. However, at 1K laser PRF, it takes approximately 20 minutes to obtain a full sample volume of 160 × 160 × 150 μm3 . To increase the imaging rate, we propose a random non-uniform sparse sampling mechanism to achieve fast sparse photoacoustic data acquisition. The image recovery process is formulated as a low-rank matrix recovery (LRMR) based on compressed sensing (CS) theory. We show that it could be stably recovered via nuclear-norm minimization optimization problem to maintain image quality from a significantly fewer measurement. In this study, we use the dual-wavelength OR-PAM with CS to visualize T cell trafficking in a 3D culture system with higher temporal resolution. Data acquisition time is reduced by 40% in such sample volume where sampling density is 0.5. The imaging system reveals the potential to understand the dynamic cellular process for preclinical screening of anti-cancer drugs.

  10. Review of the investigation of mixture formation and combustion process using rapid compression machine and direct visualization system

    Science.gov (United States)

    Jaat, M.; Khalid, Amir; Manshoor, B.; Ramsy, Him

    2013-12-01

    This paper reviews of some applications of optical visualization systems to compute the fuel-air mixing process during early stage of mixture formation in Diesel Combustion Engines. A number of studies have contributed to the understanding of fuel air mixing in DI diesel engine. This review has shown that the mixture formation process affects initial flame development. The review also found that injection pressure has a great effect on the mixture formation then the flame development and combustion characteristics. The method of the simulation of real phenomenon of diesel combustion with optical access rapid compression machine is also reviewed and experimental results are presented. The application of these methods to the investigation of diesel sprays highlights mechanisms which govern propagation and distribution of the formation of a combustible fuel-air mixture. A summary of the implementation of constant volume chamber and optical visualization system are shown in the accompanying tables and figures. The visualization of the formation process of diesel spray and its combustion in the diesel combustion chamber of diesel engine has been recognized as one of the best ways to understand the characteristics of the mixture formation.

  11. Optical sensor system for time-resolved quantification of methane concentrations: Validation measurements in a rapid compression machine

    Science.gov (United States)

    Bauke, Stephan; Golibrzuch, Kai; Wackerbarth, Hainer; Fendt, Peter; Zigan, Lars; Seefeldt, Stefan; Thiele, Olaf; Berg, Thomas

    2018-05-01

    Lowering greenhouse gas emissions is one of the most challenging demands of today's society. Especially, the automotive industry struggles with the development of more efficient internal combustion (IC) engines. As an alternative to conventional fuels, methane has the potential for a significant emission reduction. In methane fuelled engines, the process of mixture formation, which determines the properties of combustion after ignition, differs significantly from gasoline and diesel engines and needs to be understood and controlled in order to develop engines with high efficiency. This work demonstrates the development of a gas sensing system that can serve as a diagnostic tool for measuring crank-angle resolved relative air-fuel ratios in methane-fuelled near-production IC engines. By application of non-dispersive infrared absorption spectroscopy at two distinct spectral regions in the ν3 absorption band of methane around 3.3 μm, the system is able to determine fuel density and temperature simultaneously. A modified spark plug probe allows for straightforward application at engine test stations. Here, the application of the detection system in a rapid compression machine is presented, which enables validation and characterization of the system on well-defined gas mixtures under engine-like dynamic conditions. In extension to a recent proof-of-principle study, a refined data analysis procedure is introduced that allows the correction of artefacts originating from mechanical distortions of the sensor probe. In addition, the measured temperatures are compared to data obtained with a commercially available system based on the spectrally resolved detection of water absorption in the near infrared.

  12. CEPRAM: Compression for Endurance in PCM RAM

    OpenAIRE

    González Alberquilla, Rodrigo; Castro Rodríguez, Fernando; Piñuel Moreno, Luis; Tirado Fernández, Francisco

    2017-01-01

    We deal with the endurance problem of Phase Change Memories (PCM) by proposing Compression for Endurance in PCM RAM (CEPRAM), a technique to elongate the lifespan of PCM-based main memory through compression. We introduce a total of three compression schemes based on already existent schemes, but targeting compression for PCM-based systems. We do a two-level evaluation. First, we quantify the performance of the compression, in terms of compressed size, bit-flips and how they are affected by e...

  13. On the solvability of the compressible Navier–Stokes system in bounded domains

    International Nuclear Information System (INIS)

    Danchin, Raphaël

    2010-01-01

    This paper is dedicated to the well-posedness issue for the barotropic Navier–Stokes system with homogeneous Dirichlet boundary conditions in bounded domains of R N . We aim at considering data in as large a class as possible. Our main result is that if the initial density is bounded away from zero and belongs to some W 1,r with r > N, if the initial velocity is in the Besov space B 2-(2/p) r,p (and satisfies a suitable boundary condition), and if the body force is in L p loc (R + ;L r ) for some p > 1 then the system has a unique local solution. Our regularity assumptions are consistent with a dimensional analysis which shows that critical data would correspond to r = N and p = 1, and improve an old result by Solonnikov (1980 J. Sov. Math. 14 1120–32)

  14. Correlations between quality indexes of chest compression.

    Science.gov (United States)

    Zhang, Feng-Ling; Yan, Li; Huang, Su-Fang; Bai, Xiang-Jun

    2013-01-01

    Cardiopulmonary resuscitation (CPR) is a kind of emergency treatment for cardiopulmonary arrest, and chest compression is the most important and necessary part of CPR. The American Heart Association published the new Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care in 2010 and demanded for better performance of chest compression practice, especially in compression depth and rate. The current study was to explore the relationship of quality indexes of chest compression and to identify the key points in chest compression training and practice. Totally 219 healthcare workers accepted chest compression training by using Laerdal ACLS advanced life support resuscitation model. The quality indexes of chest compression, including compression hands placement, compression rate, compression depth, and chest wall recoil as well as self-reported fatigue time were monitored by the Laerdal Computer Skills and Reporting System. The quality of chest compression was related to the gender of the compressor. The indexes in males, including self-reported fatigue time, the accuracy of compression depth and the compression rate, the accuracy of compression rate, were higher than those in females. However, the accuracy of chest recoil was higher in females than in males. The quality indexes of chest compression were correlated with each other. The self-reported fatigue time was related to all the indexes except the compression rate. It is necessary to offer CPR training courses regularly. In clinical practice, it might be better to change the practitioner before fatigue, especially for females or weak practitioners. In training projects, more attention should be paid to the control of compression rate, in order to delay the fatigue, guarantee enough compression depth and improve the quality of chest compression.

  15. Convergence of a numerical method for the compressible Navier-Stokes system on general domains

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Karper, T.; Michálek, Martin

    2016-01-01

    Roč. 134, č. 4 (2016), s. 667-704 ISSN 0029-599X R&D Projects: GA ČR GA13-00522S Institutional support: RVO:67985840 Keywords : numerical methods * Navier - Stokes system Subject RIV: BA - General Mathematics Impact factor: 2.152, year: 2016 http://link.springer.com/article/10.1007%2Fs00211-015-0786-6

  16. Convergence of a numerical method for the compressible Navier-Stokes system on general domains

    Czech Academy of Sciences Publication Activity Database

    Feireisl, Eduard; Karper, T.; Michálek, Martin

    2016-01-01

    Roč. 134, č. 4 (2016), s. 667-704 ISSN 0029-599X R&D Projects: GA ČR GA13-00522S Institutional support: RVO:67985840 Keywords : numerical methods * Navier-Stokes system Subject RIV: BA - General Mathematics Impact factor: 2.152, year: 2016 http://link.springer.com/article/10.1007%2Fs00211-015-0786-6

  17. Study on a High Compression Processing for Video-on-Demand e-learning System

    Science.gov (United States)

    Nomura, Yoshihiko; Matsuda, Ryutaro; Sakamoto, Ryota; Sugiura, Tokuhiro; Matsui, Hirokazu; Kato, Norihiko

    The authors proposed a high-quality and small-capacity lecture-video-file creating system for distance e-learning system. Examining the feature of the lecturing scene, the authors ingeniously employ two kinds of image-capturing equipment having complementary characteristics : one is a digital video camera with a low resolution and a high frame rate, and the other is a digital still camera with a high resolution and a very low frame rate. By managing the two kinds of image-capturing equipment, and by integrating them with image processing, we can produce course materials with the greatly reduced file capacity : the course materials satisfy the requirements both for the temporal resolution to see the lecturer's point-indicating actions and for the high spatial resolution to read the small written letters. As a result of a comparative experiment, the e-lecture using the proposed system was confirmed to be more effective than an ordinary lecture from the viewpoint of educational effect.

  18. Influence of Elastic Bandage and Neoprene Ankle Support on Ankle Position Sense and Pain in Subjects with Ankle Sprain (Grade I & II

    Directory of Open Access Journals (Sweden)

    Basir Majdoleslami

    2004-06-01

    Full Text Available Objective: to investigate whether a neoprene ankle support and elastic bandage around the ankle joint of subjects with ankle sprain (grade I&II would , in short term (a reduce pain (b improve ankle joint position sense and comparison of their effect with each other if they have. Materials & Methods: In a semi-experimental study, 30 subjects (16men, 14 women, age between 16-52 with ankle sprain grade I&II. Subjects had to have at least 2cm from 10cm visual analogue scale (VAS of ankle pain for study entry. All patients were randomly assigned to either an elastic bandage or a neoprene ankle support. One week later they were assigned to the opposite selection. Joint position sense was assessed in the sitting position using an electrogoniometer and pain by VAS where 0cm equals no pain and 10 cm equals worst pain. ankle pain and JPS were assessed for each selection one week apart. During each visit assessment were performed at baseline and after 20 min of bandage/neoprene ankle support application. Results: the mean of scores for ankle variables JPS and VAS was taken and paired-t test and Wilcoxon signed rank test was employed to calculate the different between two trails. Neoprene ankle support had significant effect on ankle JPS (P=0.034. But elastic bandage had no effect (P=0.539. Both of them had significantly reduced ankle pain. (P=0.000  Conclusion: In subjects with both neoprene ankle support and elastic bandage reduced ankle pain with more effect of neoprene ankle support. Only the neoprene ankle support had effect on knee JPS.

  19. High-Average-Power Diffraction Pulse-Compression Gratings Enabling Next-Generation Ultrafast Laser Systems

    Energy Technology Data Exchange (ETDEWEB)

    Alessi, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-11-01

    Pulse compressors for ultrafast lasers have been identified as a technology gap in the push towards high peak power systems with high average powers for industrial and scientific applications. Gratings for ultrashort (sub-150fs) pulse compressors are metallic and can absorb a significant percentage of laser energy resulting in up to 40% loss as well as thermal issues which degrade on-target performance. We have developed a next generation gold grating technology which we have scaled to the petawatt-size. This resulted in improvements in efficiency, uniformity and processing as compared to previous substrate etched gratings for high average power. This new design has a deposited dielectric material for the grating ridge rather than etching directly into the glass substrate. It has been observed that average powers as low as 1W in a compressor can cause distortions in the on-target beam. We have developed and tested a method of actively cooling diffraction gratings which, in the case of gold gratings, can support a petawatt peak power laser with up to 600W average power. We demonstrated thermo-mechanical modeling of a grating in its use environment and benchmarked with experimental measurement. Multilayer dielectric (MLD) gratings are not yet used for these high peak power, ultrashort pulse durations due to their design challenges. We have designed and fabricated broad bandwidth, low dispersion MLD gratings suitable for delivering 30 fs pulses at high average power. This new grating design requires the use of a novel Out Of Plane (OOP) compressor, which we have modeled, designed, built and tested. This prototype compressor yielded a transmission of 90% for a pulse with 45 nm bandwidth, and free of spatial and angular chirp. In order to evaluate gratings and compressors built in this project we have commissioned a joule-class ultrafast Ti:Sapphire laser system. Combining the grating cooling and MLD technologies developed here could enable petawatt laser systems to

  20. Bi-cone system of concentric, explosion-induced D-T compression

    International Nuclear Information System (INIS)

    Kaliski, S.

    1978-01-01

    The concept and the assessment is given of the neutron yield for the bi-cone cumulative system with the aid whereof a spherical deuterized-polyethylene shell has been imploded into D-T (D) gas. The assessment of neutron yield within the limits of 10 10 - 5 x 10 10 has been obtained for D-T gas as well as 2 x 10 8 - 10 9 for D-gas. The assessments are approximate with an accuracy of an order of magnitude. (author)

  1. A Survey on Physical Factors and Compressed Breast Thickness in Voluntary Mammography Screening Using FFDM System in Malaysia: Preliminary Results

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung; Siti Kamariah Che Mohamad; Ellyda Muhamad Nordin

    2013-01-01

    This paper aims at presenting preliminary results of a survey on physical factors, namely tube potential (kV), tube current exposure time product (mAs) and compressed breast thickness (CBT) during voluntary mammography screening using Full-Field Digital Mammography (FFDM) System in Malaysia. Retrospective data were collected from 1128 FFDM images of 282 women from three major ethnic groups (Malay, Chinese and Indian) who underwent voluntary screening mammography at Breast Centre, International Islamic University Malaysia from January to March 2008. Results from the present study were then compared with results from the previous study on Screen-Film Mammography System (SFM) according to the ethnic group for both Cranio-caudal (CC) and Mediol-Lateral (MLO) views. We found that the mean kV for CC view for the three ethnic groups are Malay (28), Chinese (28) and Indian (28), and for MLO view are Malay (29), Chinese (28) and Indian (29). These values are higher than the kV for SFM which were Malay (26), Chinese (27) and Indian (26) for CC and Malay (26), Chinese (27) and Indian (26) for CC and MLO views respectively. The mean mAs for CC and MLO views for FFDM were lower compared to SFM systems. These values were Malay (104), Chinese (108) and Indian (91) for CC views and Malay (106), Chinese (105), and Indian (94) for MLO views for the FFDM system. The values for SFM system are for CC and MLO views were Malay (120), Chinese (106) and Indian (126), and Malay (166), Chinese (132), Indian (183) respectively. The median CBT for CC and MLO views increased by 27 % and 7 % respectively on the FFDM compared to the SFM system. In conclusion, the FFDM operates with higher kV, lower mAs, and higher CBT when compared with SFM system. Median CBT on CC and MLO view with FFDM system are 27 % and 7 % higher respectively compared to the SFM. We are currently collecting data on mean glandular dose with FFDM systems to assess how the change in local mammography practice influences this

  2. Clean air program : design guidelines for bus transit systems using compressed natural gas as an alternative fuel

    Science.gov (United States)

    1996-06-01

    This report documents design guidelines for the safe use of Compressed Natural Gas (CNG). The report is designed to provide guidance, information on safe industry practices, applicable national codes and standards, and reference data that transit age...

  3. Compressed air system best practice programmes: What needs to change to secure long-term energy savings for New Zealand?

    International Nuclear Information System (INIS)

    Neale, James R.; Kamp, Peter J.J.

    2009-01-01

    The establishment of a compressed air system (CAS) best practice programme is a key component of one of the initial industrial energy efficiency programmes being driven by New Zealand government ministries and agencies. In a global context this is not a new initiative in that existing programmes have been functioning in Europe and USA, yet in each of these cases the impact ten years-on has been patchy with limited long-term improvements in overall energy efficiency. The New Zealand CAS best practice programme currently under development is sponsored by the Electricity Commission (EC) and the Energy Efficiency Conservation Authority (EECA). It takes a new approach in policy direction, with variations from those used in other international programmes. A significant level of electricity levy money is to be committed to this programme and it is timely to highlight its merits and potential weaknesses, and what is required to generate long-term energy savings beyond the levels achieved by more mature overseas programmes.

  4. Class B Fire-Extinguishing Performance Evaluation of a Compressed Air Foam System at Different Air-to-Aqueous Foam Solution Mixing Ratios

    Directory of Open Access Journals (Sweden)

    Dong-Ho Rie

    2016-06-01

    Full Text Available The purpose of this research is to evaluate the fire-extinguishing performance of a compressed air foam system at different mixing ratios of pressurized air. In this system, compressed air is injected into an aqueous solution of foam and then discharged. The experimental device uses an exclusive fire-extinguishing technology with compressed air foam that is produced based on the Canada National Laboratory and UL (Underwriters Laboratories 162 standards, with a 20-unit oil fire model (Class B applied as the fire extinguisher. Compressed air is injected through the air mixture, and results with different air-to-aqueous solution foam ratios of 1:4, 1:7, and 1:10 are studied. In addition, comparison experiments between synthetic surfactant foam and a foam type which forms an aqueous film are carried out at an air-to-aqueous solution foam ratio of 1:4. From the experimental results, at identical discharging flows, it was found that the fire-extinguishing effect of the aqueous film-forming foam is greatest at an air-to-aqueous solution foam ratio of 1:7 and weakest at 1:10. Moreover, the fire-extinguishing effect of the aqueous film-forming foam in the comparison experiments between the aqueous film-forming foam and the synthetic surfactant foam is greatest.

  5. Percutaneous Stabilization System Osseofix® for Treatment of Osteoporotic Vertebral Compression Fractures - Clinical and Radiological Results after 12 Months.

    Directory of Open Access Journals (Sweden)

    Stephan Albrecht Ender

    Full Text Available A prospective consecutive cohort study (follow-up study.Our study investigated whether implantation of an expandable titanium mesh cage (Osseofix® is a successful and safe minimally invasive therapy for osteoporotic vertebral compression fractures (VCF. Our experiences, clinical and radiological findings after 12 months follow-up are presented. Kypho- and vertebroplasty are well-established minimally invasive procedures for the treatment of osteoporotic VCF. The main complications associated with both procedures are uncontrolled bone cement leakage. Therefore a suitable alternative has been investigated.During June 2010 to May 2011 24 patients were included with 32 osteoporotic VCF (T6 to L4. All of them were stabilized with the Osseofix® system. Preinterventionally we performed X-ray, MRI, and bone density measurements (DXA. Clinical and radiological results were evaluated preop., postop. and after 12 months postop. based on the Oswestry Disability Index (ODI and the Visual Analogue Scale (VAS, X-ray (Beck Index, Cobb-angle and CT.There was a significant improvement in the mean ODI (70,6% to 30,1% as well as a significant reduction in pain intensity (VAS (7,7 to 1,4 after 12 month. The mean kyphotic angle according to Cobb showed significant improvements (11,7° to 10,4° after 12 months. Postinterventional imaging showed only one case of loss of height in a stabilized vertebral body (3.1%. We saw no changes in posterior vertebral wall or adjacent fractures. Except for one pronounced postoperative hematoma we saw no surgical complications including no cement leakage.Stabilization of symptomatic osteoporotic VCF with Osseofix® system is a safe and effective procedure, even in fractures with posterior wall involvement. The clinical mid-term results are good at a very low complication rate. The Osseofix® system is an interesting alternative to the established procedures of cement augmentation.

  6. Study of a vapor-compression air-conditioning system for jetliners

    Energy Technology Data Exchange (ETDEWEB)

    Roeyttae, P.

    2009-07-01

    Most modern passenger aeroplanes use air cycle cooling. A high-speed air cycle is a reliable and light option, but not very efficient. This thesis presents research work done to design a novel vapour cooling cycle for aeroplanes. Due to advancements in high-speed permanent magnet motors, the vapour cycle is seen as a competitive option for the air cycle in aeroplanes. The aerospace industry placews tighter demands on the weight, reliability and environmental effects of the machinery than those met by conventional chillers, and thus modifications to conventional design are needed. The thesis is divided into four parts: the initial screening of the working fluid, 1-D design and performance values of the compressor, 1-D off-design value predictions of the compressor and the 3-D design of the compressor. The R24fa was selected as the working fluid based the study. The off-design range of the compressor was predicted to be wide and suitable for the application. The air-conditioning system developed is considerably smaller than previous designs using centrifugal compressors. (orig.)

  7. Modelling study, efficiency analysis and optimisation of large-scale Adiabatic Compressed Air Energy Storage systems with low-temperature thermal storage

    International Nuclear Information System (INIS)

    Luo, Xing; Wang, Jihong; Krupke, Christopher; Wang, Yue; Sheng, Yong; Li, Jian; Xu, Yujie; Wang, Dan; Miao, Shihong; Chen, Haisheng

    2016-01-01

    Highlights: • The paper presents an A-CAES system thermodynamic model with low temperature thermal energy storage integration. • The initial parameter value ranges for A-CAES system simulation are identified from the study of a CAES plant in operation. • The strategies of system efficiency improvement are investigated via a parametric study with a sensitivity analysis. • Various system configurations are discussed for analysing the efficiency improvement potentials. - Abstract: The key feature of Adiabatic Compressed Air Energy Storage (A-CAES) is the reuse of the heat generated from the air compression process at the stage of air expansion. This increases the complexity of the whole system since the heat exchange and thermal storage units must have the capacities and performance to match the air compression/expansion units. Thus it raises a strong demand in the whole system modelling and simulation tool for A-CAES system optimisation. The paper presents a new whole system mathematical model for A-CAES with simulation implementation and the model is developed with consideration of lowing capital cost of the system. The paper then focuses on the study of system efficiency improvement strategies via parametric analysis and system structure optimisation. The paper investigates how the system efficiency is affected by the system component performance and parameters. From the study, the key parameters are identified, which give dominant influences in improving the system efficiency. The study is extended onto optimal system configuration and the recommendations are made for achieving higher efficiency, which provides a useful guidance for A-CAES system design.

  8. Theoretical studies of a hybrid ejector CO2 compression cooling system for vehicles and preliminary experimental investigations of an ejector cycle

    International Nuclear Information System (INIS)

    Chen, Xiangjie; Worall, Mark; Omer, Siddig; Su, Yuehong; Riffat, Saffa

    2013-01-01

    Highlights: ► Waste heat from vehicle exhausted gas was used as heat source for ejector. ► Ejector acts as the main interface between ejector and CO 2 VC sub-system. ► The effect of sub-cooling was analyzed. ► COP of ejector cooling system was measured between 0.2 and 0.5 during experiments. ► Enhanced ejector and vapour compression system. -- Abstract: This paper presents theoretical investigations into a hybrid ejector and CO 2 vapour compression (VC) system for road transport cooling. The purpose is to utilise the waste heat from exhaust gas and the VC sub-system to drive the ejector system, whose cooling effect will be employed to subcool the VC sub-system. Exploitation of the energy consumption ratio between ejector sub-system and CO 2 VC sub-system indicated that the more energy obtained from exhausted gas, the better system performance could be achieved for CO 2 VC sub-system, and hence higher cooling capacity of the VC sub-system at the same compression power. Thermodynamic simulations of two sub-systems and the hybrid system were presented. The results indicated that, at boiler temperature of 120 °C, evaporator temperature of 10 °C, a COP of 0.584 was achieved for hybrid system, with 22% improvement over a single ejector cycle. Preliminary experimental studies were carried out on a single ejector cycle, with boiler temperatures between 115 °C and 130 °C, and evaporator temperatures between 5 °C and 10 °C. The effects of various operation conditions on the overall ejector operation were coherently analysed. The COP of the ejector sub-system from experimental results was approximately 85% compared with simulation results, which showed a good agreement between theoretical analysis and experimental results.

  9. Thermoeconomic analysis of an integrated multi-effect desalination thermal vapor compression (MED-TVC) system with a trigeneration system using triple-pressure HRSG

    Science.gov (United States)

    Ghaebi, Hadi; Abbaspour, Ghader

    2018-05-01

    In this research, thermoeconomic analysis of a multi-effect desalination thermal vapor compression (MED-TVC) system integrated with a trigeneration system with a gas turbine prime mover is carried out. The integrated system comprises of a compressor, a combustion chamber, a gas turbine, a triple-pressure (low, medium and high pressures) heat recovery steam generator (HRSG) system, an absorption chiller cycle (ACC), and a multi-effect desalination (MED) system. Low pressure steam produced in the HRSG is used to drive absorption chiller cycle, medium pressure is used in desalination system and high pressure superheated steam is used for heating purposes. For thermodynamic and thermoeconomic analysis of the proposed integrated system, Engineering Equation Solver (EES) is used by employing mass, energy, exergy, and cost balance equations for each component of system. The results of the modeling showed that with the new design, the exergy efficiency in the base design will increase to 57.5%. In addition, thermoeconomic analysis revealed that the net power, heating, fresh water and cooling have the highest production cost, respectively.

  10. A Study on the Data Compression Technology-Based Intelligent Data Acquisition (IDAQ System for Structural Health Monitoring of Civil Structures

    Directory of Open Access Journals (Sweden)

    Gwanghee Heo

    2017-07-01

    Full Text Available In this paper, a data compression technology-based intelligent data acquisition (IDAQ system was developed for structural health monitoring of civil structures, and its validity was tested using random signals (El-Centro seismic waveform. The IDAQ system was structured to include a high-performance CPU with large dynamic memory for multi-input and output in a radio frequency (RF manner. In addition, the embedded software technology (EST has been applied to it to implement diverse logics needed in the process of acquiring, processing and transmitting data. In order to utilize IDAQ system for the structural health monitoring of civil structures, this study developed an artificial filter bank by which structural dynamic responses (acceleration were efficiently acquired, and also optimized it on the random El-Centro seismic waveform. All techniques developed in this study have been embedded to our system. The data compression technology-based IDAQ system was proven valid in acquiring valid signals in a compressed size.

  11. PARAMETRIC STUDY OF ENERGY, EXERGY AND THERMOECONOMIC ANALYSES ON VAPOR-COMPRESSION SYSTEM CASCADED WITH LIBR/WATER AND NH3/WATER ABSORBTION CASCADE REFRIGERATION CYCLE

    Directory of Open Access Journals (Sweden)

    ahmet selim dalkilic

    2017-03-01

    Full Text Available Energy savings on cooling systems can be performed by using novel refrigeration cycles. For this aim, vapour compression-vapour absorption cascade refrigeration systems can be considered as substitute to single-stage vapour compression refrigeration systems. Renewable energy sources of geothermal and solar heat, waste heat of processes have been used by these cycles to provide cooling and they also require less electrical energy than vapour compression cycles having alternative refrigerants. In this study, a vapour compression (VC and vapour absorption (VA cascade systems are analysed with the second law analysis for varied cooling capacities. While lithium bromide-water and NH3/H2O are the working fluids in VA part, various refrigerants are used in VC section. The refrigerants of R134a and R600a, R410A and R407C are tested as drop in alternatives for R12 and R22, respectively. The effects of alteration in cooling capacity, superheating and sub cooling in VC part, temperature in the generator and absorber, and degree of overlap in cascade condenser in VA part on the coefficient of system performance are studied. Validation of the results have been performed by the values given in the literature. Improvement in COP of VC, VA and cascade system are obtained separately. According to the analyses, cascade systems’ COP values increase with increasing the temperatures of generator and evaporator and they also increase with decreasing the condenser and absorber temperatures. Moreover, the generator has the highest exergy destruction rates, second and third one were the condenser and absorber, respectively. Electricity consumption and payback period are also determined considering the various parameters of the study.

  12. Novel, high-definition 3-D endoscopy system with real-time compression communication system to aid diagnoses and treatment between hospitals in Thailand.

    Science.gov (United States)

    Uemura, Munenori; Kenmotsu, Hajime; Tomikawa, Morimasa; Kumashiro, Ryuichi; Yamashita, Makoto; Ikeda, Testuo; Yamashita, Hiromasa; Chiba, Toshio; Hayashi, Koichi; Sakae, Eiji; Eguchi, Mitsuo; Fukuyo, Tsuneo; Chittmittrapap, Soottiporn; Navicharern, Patpong; Chotiwan, Pornarong; Pattana-Arum, Jirawat; Hashizume, Makoto

    2015-05-01

    Traditionally, laparoscopy has been based on 2-D imaging, which represents a considerable challenge. As a result, 3-D visualization technology has been proposed as a way to better facilitate laparoscopy. We compared the latest 3-D systems with high-end 2-D monitors to validate the usefulness of new systems for endoscopic diagnoses and treatment in Thailand. We compared the abilities of our high-definition 3-D endoscopy system with real-time compression communication system with a conventional high-definition (2-D) endoscopy system by asking health-care staff to complete tasks. Participants answered questionnaires and whether procedures were easier using our system or the 2-D endoscopy system. Participants were significantly faster at suture insertion with our system (34.44 ± 15.91 s) than with the 2-D system (52.56 ± 37.51 s) (P < 0.01). Most surgeons thought that the 3-D system was good in terms of contrast, brightness, perception of the anteroposterior position of the needle, needle grasping, inserting the needle as planned, and needle adjustment during laparoscopic surgery. Several surgeons highlighted the usefulness of exposing and clipping the bile duct and gallbladder artery, as well as dissection from the liver bed during laparoscopic surgery. In an image-transfer experiment with RePure-L®, participants at Rajavithi Hospital could obtain reconstructed 3-D images that were non-inferior to conventional images from Chulalongkorn University Hospital (10 km away). These data suggest that our newly developed system could be of considerable benefit to the health-care system in Thailand. Transmission of moving endoscopic images from a center of excellence to a rural hospital could help in the diagnosis and treatment of various diseases. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  13. Study on Axial Compressive Capacity of FRP-Confined Concrete-Filled Steel Tubes and Its Comparisons with Other Composite Structural Systems

    Directory of Open Access Journals (Sweden)

    Jun Deng

    2017-01-01

    Full Text Available Concrete-filled steel tubular (CFST columns have been widely used for constructions in recent decades because of their high axial strength. In CFSTs, however, steel tubes are susceptible to degradation due to corrosion, which results in the decrease of axial strength of CFSTs. To further improve the axial strength of CFST columns, carbon fiber reinforced polymer (CFRP sheets and basalt fiber reinforced polymer (BFRP sheets are applied to warp the CFSTs. This paper presents an experimental study on the axial compressive capacity of CFRP-confined CFSTs and BFRP-confined CFSTs, which verified the analytical model with considering the effect of concrete self-stressing. CFSTs wrapped with FRP exhibited a higher ductile behavior. Wrapping with CFRP and BFRP improves the axial compressive capacity of CFSTs by 61.4% and 17.7%, respectively. Compared with the previous composite structural systems of concrete-filled FRP tubes (CFFTs and double-skin tubular columns (DSTCs, FRP-confined CFSTs were convenient in reinforcing existing structures because of softness of the FRP sheets. Moreover, axial compressive capacity of CFSTs wrapped with CFRP sheets was higher than CFFTs and DSTCs, while the compressive strength of DSTCs was higher than the retrofitted CFSTs.

  14. DNABIT Compress – Genome compression algorithm

    OpenAIRE

    Rajarajeswari, Pothuraju; Apparao, Allam

    2011-01-01

    Data compression is concerned with how information is organized in data. Efficient storage means removal of redundancy from the data being stored in the DNA molecule. Data compression algorithms remove redundancy and are used to understand biologically important molecules. We present a compression algorithm, “DNABIT Compress” for DNA sequences based on a novel algorithm of assigning binary bits for smaller segments of DNA bases to compress both repetitive and non repetitive DNA sequence. Our ...

  15. Video Bandwidth Compression System.

    Science.gov (United States)

    1980-08-01

    scaling function, located between the inverse DPCM and inverse transform , on the decoder matrix multiplier chips. 1"V1 T.. ---- i.13 SECURITY...Bit Unpacker and Inverse DPCM Slave Sync Board 15 e. Inverse DPCM Loop Boards 15 f. Inverse Transform Board 16 g. Composite Video Output Board 16...36 a. Display Refresh Memory 36 (1) Memory Section 37 (2) Timing and Control 39 b. Bit Unpacker and Inverse DPCM 40 c. Inverse Transform Processor 43

  16. DNABIT Compress – Genome compression algorithm

    Science.gov (United States)

    Rajarajeswari, Pothuraju; Apparao, Allam

    2011-01-01

    Data compression is concerned with how information is organized in data. Efficient storage means removal of redundancy from the data being stored in the DNA molecule. Data compression algorithms remove redundancy and are used to understand biologically important molecules. We present a compression algorithm, “DNABIT Compress” for DNA sequences based on a novel algorithm of assigning binary bits for smaller segments of DNA bases to compress both repetitive and non repetitive DNA sequence. Our proposed algorithm achieves the best compression ratio for DNA sequences for larger genome. Significantly better compression results show that “DNABIT Compress” algorithm is the best among the remaining compression algorithms. While achieving the best compression ratios for DNA sequences (Genomes),our new DNABIT Compress algorithm significantly improves the running time of all previous DNA compression programs. Assigning binary bits (Unique BIT CODE) for (Exact Repeats, Reverse Repeats) fragments of DNA sequence is also a unique concept introduced in this algorithm for the first time in DNA compression. This proposed new algorithm could achieve the best compression ratio as much as 1.58 bits/bases where the existing best methods could not achieve a ratio less than 1.72 bits/bases. PMID:21383923

  17. A new XML-aware compression technique for improving performance of healthcare information systems over hospital networks.

    Science.gov (United States)

    Al-Shammary, Dhiah; Khalil, Ibrahim

    2010-01-01

    Most organizations exchange, collect, store and process data over the Internet. Many hospital networks deploy Web services to send and receive patient information. SOAP (Simple Object Access Protocol) is the most usable communication protocol for Web services. XML is the standard encoding language of SOAP messages. However, the major drawback of XML messages is the high network traffic caused by large overheads. In this paper, two XML-aware compressors are suggested to compress patient messages stemming from any data transactions between Web clients and servers. The proposed compression techniques are based on the XML structure concepts and use both fixed-length and Huffman encoding methods for translating the XML message tree. Experiments show that they outperform all the conventional compression methods and can save tremendous amount of network bandwidth.

  18. Implementation of a multi-lingual, Internet-supported benchmarking system for compressed-air installations; Umsetzung eines mehrsprachigen internetgestuetzten Benchmarking von Druckluftanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Radgen, P.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) discusses how know-how can be improved and how optimisation activities can be stimulated in the area of compressed-air generation. The authors estimate that potential energy-savings of 20 to 40% are possible. The aim of the project - to introduce a benchmarking system already in use in Germany to the Swiss market - is discussed. This benchmarking is to help companies identify weak points in their compressed-air systems. An Internet-based information platform is introduced which was realised in 2004 and is being continually extended. The use of the benchmarking process is illustrated with a comprehensive flow-diagram and 'screen-shots' of the relevant Internet pages.

  19. Development of a Next-Generation Membrane-Integrated Adsorption Processor for CO2 Removal and Compression for Closed-Loop Air Revitalization Systems

    Science.gov (United States)

    Mulloth, Lila; LeVan, Douglas

    2002-01-01

    The current CO2 removal technology of NASA is very energy intensive and contains many non-optimized subsystems. This paper discusses the concept of a next-generation, membrane integrated, adsorption processor for CO2 removal nd compression in closed-loop air revitalization systems. This processor will use many times less power than NASA's current CO2 removal technology and will be capable of maintaining a lower CO2 concentration in the cabin than that can be achieved by the existing CO2 removal systems. The compact, consolidated, configuration of gas dryer, CO2 separator, and CO2 compressor will allow continuous recycling of humid air in the cabin and supply of compressed CO2 to the reduction unit for oxygen recovery. The device has potential application to the International Space Station and future, long duration, transit, and planetary missions.

  20. A 158 fs 5.3 nJ fiber-laser system at 1 mu m using photonic bandgap fibers for dispersion control and pulse compression

    DEFF Research Database (Denmark)

    Nielsen, C.K.; Jespersen, Kim Giessmann; Keiding, S.R.

    2006-01-01

    We demonstrate a 158 fs 5.3 nJ mode-locked laser system based on a fiber oscillator, fiber amplifier and fiber compressor. Dispersion compensation in the fiber oscillator was obtained with a solid-core photonic bandgap (SC-PBG) fiber spliced to standard fibers, and external compression is obtained...... with a hollow-core photonic bandgap (HC-PBG) fiber....