WorldWideScience

Sample records for composite international diagnostic

  1. Validity of Chinese Version of the Composite International Diagnostic Interview-3.0 in Psychiatric Settings

    Institute of Scientific and Technical Information of China (English)

    Jin Lu; Yue-Qin Huang; Zhao-Rui Liu; Xiao-Lan Cao

    2015-01-01

    Background:The Composite International Diagnostic Interview-3.0 (CIDI-3.0) is a fully structured lay-administered diagnostic interview for the assessment of mental disorders according to ICD-10 and Diagnostic and Statistical Manual of Mental Disorders,Fourth Edition (DSM-Ⅳ) criteria.The aim of the study was to investigate the concurrent validity of the Chinese CIDI in diagnosing mental disorders in psychiatric settings.Methods:We recruited 208 participants,of whom 148 were patients from two psychiatric hospitals and 60 healthy people from communities.These participants were administered with CIDI by six trained lay interviewers and the Structured Clinical Interview for DSM-Ⅳ Axis I Disorders (SCID-I,gold standard) by two psychiatrists.Agreement between CIDI and SCID-I was assessed with sensitivity,specificity,positive predictive value and negative predictive value.Individual-level CIDI-SCID diagnostic concordance was evaluated using the area under the receiver operator characteristic curve and Cohen's K.Results:Substantial to excellent CIDI to SCID concordance was found for any substance use disorder (area under the receiver operator characteristic curve [AUC] =0.926),any anxiety disorder (AUC =0.807) and any mood disorder (AUC =0.806).The concordance between the CIDI and the SCID for psychotic and eating disorders is moderate.However,for individual mental disorders,the CIDI-SCID concordance for bipolar disorders (AUC =0.55) and anorexia nervosa (AUC =0.50) was insufficient.Conclusions:Overall,the Chinese version of CIDI-3.0 has acceptable validity in diagnosing the substance use disorder,anxiety disorder and mood disorder among Chinese adult population.However,we should be cautious when using it for bipolar disorders and anorexia nervosa.

  2. Validity of Chinese Version of the Composite International Diagnostic Interview-3.0 in Psychiatric Settings

    Directory of Open Access Journals (Sweden)

    Jin Lu

    2015-01-01

    Full Text Available Background: The Composite International Diagnostic Interview-3.0 (CIDI-3.0 is a fully structured lay-administered diagnostic interview for the assessment of mental disorders according to ICD-10 and Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV criteria. The aim of the study was to investigate the concurrent validity of the Chinese CIDI in diagnosing mental disorders in psychiatric settings. Methods: We recruited 208 participants, of whom 148 were patients from two psychiatric hospitals and 60 healthy people from communities. These participants were administered with CIDI by six trained lay interviewers and the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I, gold standard by two psychiatrists. Agreement between CIDI and SCID-I was assessed with sensitivity, specificity, positive predictive value and negative predictive value. Individual-level CIDI-SCID diagnostic concordance was evaluated using the area under the receiver operator characteristic curve and Cohen′s K. Results: Substantial to excellent CIDI to SCID concordance was found for any substance use disorder (area under the receiver operator characteristic curve [AUC] = 0.926, any anxiety disorder (AUC = 0.807 and any mood disorder (AUC = 0.806. The concordance between the CIDI and the SCID for psychotic and eating disorders is moderate. However, for individual mental disorders, the CIDI-SCID concordance for bipolar disorders (AUC = 0.55 and anorexia nervosa (AUC = 0.50 was insufficient. Conclusions: Overall, the Chinese version of CIDI-3.0 has acceptable validity in diagnosing the substance use disorder, anxiety disorder and mood disorder among Chinese adult population. However, we should be cautious when using it for bipolar disorders and anorexia nervosa.

  3. The reliability of the Brazilian version of the Composite International Diagnostic Interview (CIDI 2.1

    Directory of Open Access Journals (Sweden)

    Quintana M.I.

    2004-01-01

    Full Text Available The objective of the present study was to determine the reliability of the Brazilian version of the Composite International Diagnostic Interview 2.1 (CIDI 2.1 in clinical psychiatry. The CIDI 2.1 was translated into Portuguese using WHO guidelines and reliability was studied using the inter-rater reliability method. The study sample consisted of 186 subjects from psychiatric hospitals and clinics, primary care centers and community services. The interviewers consisted of a group of 13 lay and three non-lay interviewers submitted to the CIDI training. The average interview time was 2 h and 30 min. General reliability ranged from kappa 0.50 to 1. For lifetime diagnoses the reliability ranged from kappa 0.77 (Bipolar Affective Disorder to 1 (Substance-Related Disorder, Alcohol-Related Disorder, Eating Disorders. Previous year reliability ranged from kappa 0.66 (Obsessive-Compulsive Disorder to 1 (Dissociative Disorders, Maniac Disorders, Eating Disorders. The poorest reliability rate was found for Mild Depressive Episode (kappa = 0.50 during the previous year. Training proved to be a fundamental factor for maintaining good reliability. Technical knowledge of the questionnaire compensated for the lack of psychiatric knowledge of the lay personnel. Inter-rater reliability was good to excellent for persons in psychiatric practice.

  4. Analysis of mental disorders in tinnitus patients performed with Composite International Diagnostic Interview.

    Science.gov (United States)

    Zirke, N; Seydel, C; Arsoy, D; Klapp, B F; Haupt, H; Szczepek, A J; Olze, H; Goebel, G; Mazurek, B

    2013-10-01

    Known association between tinnitus and psychological distress prompted us to examine patients with chronic tinnitus by using the Composite International Diagnostic Interview (CIDI), which is a standardized and reliable method used for the diagnosis of mental disorders. One hundred patients with chronic tinnitus admitted to the Tinnitus Center, Charité-Universitätsmedizin Berlin, were included in this study. Data were collected between February 2008 and February 2009. Besides CIDI, the Tinnitus Questionnaire according to Goebel and Hiller, the Hospital Anxiety Depression Scale, and the General Anxiety Disorder-7 were used. Using CIDI, we have identified one or more mental disorders in 46 tinnitus patients. In that group, we found persistent affective disorders (37 %), anxiety disorders (32 %), and somatoform disorders (27 %). Those patients who had affective or anxiety disorders were more distressed by tinnitus and were more anxious and more depressed than tinnitus patients without mental disorders. Psychological impairment positively correlated with tinnitus distress: Patients with decompensated tinnitus had significantly more affective and anxiety disorders than patients with compensated tinnitus. In the present study, we have detected a high rate (almost half of the cases) of psychological disorders occurring in patients with chronic tinnitus. The patients diagnosed with psychological disorders were predominantly affected by affective and anxiety disorders. Psychological disorders were associated with severity of tinnitus distress. Our findings imply a need for routine comprehensive screening of mental disorders in patients with chronic tinnitus.

  5. Negative and positive participant responses to the composite international diagnostic interview - Results of the Netherlands Mental Health Survey and Incidence Study

    NARCIS (Netherlands)

    Graaf, R. de; Have, M.L. ten; Dorsselaer, S.A.F.M. van; Schoemaker, C.G.; Vollebergh, W.A.M.

    2004-01-01

    Little is known about the emotional responses of participants in community surveys to standardised psychiatric interviews like the Composite International Diagnostic Interview (CIDI). This study investigates the proportion of subjects responding negatively or positively to the CIDI, and identifies

  6. Validity of a Farsi translation of the composite International Diagnostic Interview (CIDI to diagnose schizophrenia and bipolar disorder

    Directory of Open Access Journals (Sweden)

    H. Amini

    2006-08-01

    Full Text Available Background: The Composite International Diagnostic Interview (CIDI is a comprehensive, standardized diagnostic interview for the assessment of psychiatric disorders. There have been few studies on the validity of the CIDI. The objective of present study was to assess the validity of a Farsi translation of the complete CIDI and its psychosis/mania module in five referral clinical psychiatric settings. Methods: Two hundred and three as well as 104 consecutive admissions were interviewed using the complete and the psychosis/mania module, respectively. Within two days of the CIDI interview, two last year residents of psychiatry or psychiatrist who were blind to the CIDI diagnosis completed the Clinical diagnostic checklists (based on DSM-IV and ICD-10 criteria simultaneously and reached the consensus diagnosis. Data analysis was performed using SPSS 11 to determine the validity of CIDI. Results: The sensitivity and specificity for the diagnosis of schizophrenia was 0.12 and 0.96 using DSM-IV criteria. According to ICD-10 criteria, the results were the same with 0.19% sensitivity and 0.96% specificity. The sensitivity for the diagnosis of bipolar I disorder was low (0.21 using DSM-IV criteria and 0.17% using ICD-10 and specificity, high (0.90 compared to DSM-IV and 0.89 compared to ICD-10 criteria. The results were rather similar for the psychosis/mania module of CIDI. Conclusion: This study suggests that the Farsi translation of both the complete CIDI and the psychosis/mania module of CIDI have good specificity, but poor sensitivity for the diagnosis of schizophrenia and of bipolar I disorder.

  7. Cultural adaptation of the Latin American version of the World Health Organization Composite International Diagnostic Interview (WHO-CIDI) (v 3.0) for use in Spain.

    Science.gov (United States)

    Navarro-Mateu, Fernando; Morán-Sánchez, Inés; Alonso, Jordi; Tormo, Ma José; Pujalte, Ma Luisa; Garriga, Ascensión; Aguilar-Gaxiola, Sergio; Navarro, Carmen

    2013-01-01

    To develop a Spanish version of the WHO-Composite International Diagnostic Interview (WHO-CIDI) applicable to Spain, through cultural adaptation of its most recent Latin American (LA v 20.0) version. A 1-week training course on the WHO-CIDI was provided by certified trainers. An expert panel reviewed the LA version, identified words or expressions that needed to be adapted to the cultural or linguistic norms for Spain, and proposed alternative expressions that were agreed on through consensus. The entire process was supervised and approved by a member of the WHO-CIDI Editorial Committee. The changes were incorporated into a Computer Assisted Personal Interview (CAPI) format and the feasibility and administration time were pilot tested in a convenience sample of 32 volunteers. A total of 372 questions were slightly modified (almost 7% of approximately 5000 questions in the survey) and incorporated into the CAPI version of the WHO-CIDI. Most of the changes were minor - but important - linguistic adaptations, and others were related to specific Spanish institutions and currency. In the pilot study, the instrument's mean completion administration time was 2h and 10min, with an interquartile range from 1.5 to nearly 3h. All the changes made were tested and officially approved. The Latin American version of the WHO-CIDI was successfully adapted and pilot-tested in its computerized format and is now ready for use in Spain. Copyright © 2012 SESPAS. Published by Elsevier Espana. All rights reserved.

  8. Diagnostic imaging in internal medicine

    International Nuclear Information System (INIS)

    Eisenberg, R.L.

    1985-01-01

    This book examines medical diagnostic techniques. Topics considered include biological considerations in the approach to clinical medicines; infectious diseases; disorders of the heart; disorders of the vascular system; disorders of the respiratory system; diseases of the kidneys and urinary tract; disorders of the alimentary tract; disorders of the hepatobiliary system and pancreas; disorders of the hematopoietic system; disorders of bone and bone mineralization; disorders of the joints, connective tissues, and striated muscles; disorders of the nervous system; miscellaneous disorders; and procedures in diagnostic imaging

  9. International Workshop on Diagnostics for ITER

    CERN Document Server

    Gorini, Giuseppe; Sindoni, Elio

    1996-01-01

    This book of proceedings collects the papers presented at the Workshop on Diagnostics for ITER, held at Villa Monastero, Varenna (Italy), from August 28 to September 1, 1995. The Workshop was organised by the International School of Plasma Physics "Piero Caldirola. " Established in 1971, the ISPP has organised over fifty advanced courses and workshops on topics mainly related to plasma physics. In particular, courses and workshops on plasma diagnostics (previously held in 1975, 1978, 1982, 1986, and 1991) can be considered milestones in the history of this institution. Looking back at the proceedings of the previous meetings in Varenna, one can appreciate the rapid progress in the field of plasma diagnostics over the past 20 years. The 1995 workshop was co-organised by the Istituto di Fisica del Plasma of the National Research Council (CNR). In contrast to previous Varenna meetings on diagnostics, which have covered diagnostics in present-day tokamaks and which have had a substantial tutorial component, the 1...

  10. 78 FR 39327 - Bio Diagnostic International; Denial of Application

    Science.gov (United States)

    2013-07-01

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration [Docket No. 11-63] Bio Diagnostic... Control, Drug Enforcement Administration, issued an Order to Show Cause to Bio Diagnostic International... application of Bio Diagnostic International, Inc., for a DEA Certificate of Registration as a distributor of...

  11. Diagnostics of internal inductance in HT-7

    International Nuclear Information System (INIS)

    Zeng Li; Wan Baonian; Qian Jinping; Fan Hengyu

    2001-01-01

    Two arrays of Mirnov coils and a pair of concentric loops have been installed to superconducting tokamak HT-7. Software compensation and digital Fourier series expansion are the two techniques that have been applied successfully in measuring diamagnetic flux of concentric loops and internal inductance. The internal inductance of plasma l i , poloidal beta β p , Grad Shafranov parameter Λ, plasma minor radius α p and the center of the outermost magnetic flux surface Δ g are determined

  12. Accuracy of the Composite International Diagnostic Interview (CIDI 2.1 for diagnosis of post-traumatic stress disorder according to DSM-IV criteria Validade do diagnóstico de transtorno de estresse pós-traumático do Composite International Diagnostic Interview (CIDI 2.1 de acordo com os critérios diagnósticos da DSM-IV

    Directory of Open Access Journals (Sweden)

    Maria Inês Quintana

    2012-07-01

    Full Text Available The objective was to study the accuracy of the post-traumatic stress disorder (PTSD section of the Composite International Diagnostic Interview (CIDI 2.1 DSM-IV diagnosis, using the Structured Clinical Interview (SCID as gold standard, and compare the ICD-10 and DSM IV classifications for PTSD. The CIDI was applied by trained lay interviewers and the SCID by a psychologist. The subjects were selected from a community and an outpatient program. A total of 67 subjects completed both assessments. Kappa coefficients for the ICD-10 and the DSM IV compared to the SCID diagnosis were 0.67 and 0.46 respectively. Validity for the DSM IV diagnosis was: sensitivity (51.5%, specificity (94.1%, positive predictive value (9.5%, negative predictive value (66.7%, misclassification rate (26.9%. The CIDI 2.1 demonstrated low validity coefficients for the diagnosis of PTSD using DSM IV criteria when compared to the SCID. The main source of discordance in this study was found to be the high probability of false-negative cases with regards to distress and impairment as well as to avoidance symptoms.O objetivo deste artigo foi estudar a validade concorrente da seção de transtorno de estresse pós-traumático do CIDI 2.1 critérios DSM IV, utilizando o Structured Clinical Interview (SCID como padrão-ouro, e comparar o diagnóstico de TEPT entre CID-10 e DSM IV. O CIDI foi aplicado por entrevistadores leigos treinados e o SCID por uma psicóloga. A amostra foi composta por sujeitos da comunidade e de um ambulatório de especialidade psiquiátrica. Sessenta e sete sujeitos completaram ambos os questionários. O coeficiente kappa foi de 0.46 ao comparar DSM IV com a SCID. A validade diagnóstica usando critérios do DSM IV foi de: sensibilidade = 51.5%, especificidade = 94.1%, valor preditivo positivo = 89.5%, valor preditivo negativo = 66.7%, taxa de classificação incorreta = 26.9%. O CIDI 2.1 apresentou valores baixos para os coeficientes de validação de TEPT

  13. Bone Composition Diagnostics: Photoacoustics Versus Ultrasound

    Science.gov (United States)

    Yang, Lifeng; Lashkari, Bahman; Mandelis, Andreas; Tan, Joel W. Y.

    2015-06-01

    Ultrasound (US) backscatter from bones depends on the mechanical properties and the microstructure of the interrogated bone. On the other hand, photoacoustics (PA) is sensitive to optical properties of tissue and can detect composition variation. Therefore, PA can provide complementary information about bone health and integrity. In this work, a comparative study of US backscattering and PA back-propagating signals from animal trabecular bones was performed. Both methods were applied using a linear frequency modulation chirp and matched filtering. A 2.2 MHz ultrasonic transducer was employed to detect both signals. The use of the frequency domain facilitates spectral analysis. The variation of signals shows that in addition to sensitivity to mineral changes, PA exhibits sensitivity to changes in the organic part of the bone. It is, therefore, concluded that the combination of both modalities can provide complementary detailed information on bone health than either method separately. In addition, comparison of PA and US depthwise images shows the higher penetration of US. Surface scan images exhibit very weak correlation between US and PA which could be caused by the different signal generation origins in mechanical versus optical properties, respectively.

  14. International Conference on Plasma Diagnostics. Slides, papers and posters of Plasma Diagnostics 2010

    International Nuclear Information System (INIS)

    Hartfuss, H.J.; Bonhomme, G.; Grisolia, C.; Hirsch, M.; Klos, Z.; Mazouffre, S.; Musielok, J.; Ratynskaya, S.; Sadowski, M.; Van de Sanden, R.; Sentis, M.; Stroth, U.; Tereshin, V.; Tichy, M.; Unterberg, B.; Weisen, H.; Zoletnik, S.

    2011-01-01

    Plasma diagnostics 2010 is an International Conference on Diagnostic Methods involved in Research and Applications of Plasmas, originating on combining the 5. German-Polish Conference on Plasma Diagnostics for Fusion and Applications and the 7. French-Polish Seminar on Thermal Plasma in Space and Laboratory. The Scientific Committee of 'Plasma 2007' decided to concentrate the attention of future conferences more on the diagnostic development and diagnostic interpretation in the fields of high and low temperature plasmas and plasma applications. It is aimed at involving all European activities in the fields. The Scientific Program will cover the fields from low temperature laboratory to fusion plasmas of various configurations as well as dusty and astrophysical plasmas and industrial plasma applications

  15. [Sensitivity and specificity between the Composite International Diagnostic Interview Version 3.0 (World Mental Health, CIDI) and the Standardised Clinical Evaluation version I (SCID-I) in a mental health survey of the city of Medellin, 2012].

    Science.gov (United States)

    Montoya Gonzalez, Laura Elisa; Restrepo Bernal, Diana Patricia; Mejía-Montoya, Roberto; Bareño-Silva, José; Sierra-Hincapié, Gloria; Torres de Galvis, Yolanda; Marulanda-Restrepo, Daniel; Gómez-Sierra, Natalia; Gaviria-Arbeláez, Silvia

    2016-01-01

    In order to address the mental health problems of the Colombian population it is necessary to have diagnostic tools (local and international) that are valid, easy to apply, and comparable. To compare the sensitivity and specificity between the CIDI 3.0 and the SCID-I for major depressive disorder, bipolar I and II disorder, and substance dependence disorder. Cross-sectional study comparing the life prevalence of three mental disorders in 100 subjects using the CIDI 3.0 and the SCID-I. The study was approved by the Institutional Ethics Committee. The two diagnostic interviews were performed that measured by sensitivity, specificity, positive predictive value and negative predictive value with confidence intervals of 95%. The SPSS version 21.0 software was used for data analysis. The median age was 43.5 years, with an interquartile interval of 30 years. The highest sensitivity (Se) and specificity (Sp) was observed for drug dependence diagnosis - with 80%, (95%CI, 34.94-100), and 98.46 (95%CI, 94.7-100), respectively. SCID-I and CIDI 3.0 showed different levels of sensitivity and specificity for the three disorders studied with: high for substance dependence disorder, moderate for bipolar disorder I and II, and low for major depressive disorder. Copyright © 2015 Asociación Colombiana de Psiquiatría. All rights reserved.

  16. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  17. Exploring the Diagnostic Utility of Facial Composites: Beliefs of Guilt Can Bias Perceived Similarity between Composite and Suspect

    Science.gov (United States)

    Charman, Steve D.; Gregory, Amy Hyman; Carlucci, Marianna

    2009-01-01

    Facial composite research has generally focused on the investigative utility of composites--using composites to find suspects. However, almost no work has examined the diagnostic utility of facial composites--the extent to which composites can be used as evidence against a suspect. For example, detectives and jurors may use the perceived…

  18. [Pharmacovigilance center --internal medicine interactions: A useful diagnostic tool].

    Science.gov (United States)

    Rochoy, M; Gautier, S; Bordet, R; Caron, J; Launay, D; Hachulla, E; Hatron, P-Y; Lambert, M

    2015-08-01

    Patients hospitalized in internal medicine often have unexplained clinical symptoms for which a drug origin can be considered. The prevalence of patients hospitalized for iatrogenic is estimated between 4-22%. We wanted to evaluate the diagnostic value of the regional center of pharmacovigilance to identify or confirm an iatrogenic disease in the department of internal medicine of Lille and characterize factors associated with drug-related side effect. This is a single-center prospective diagnostic study. We included all subsequent requests from the department of internal medicine with the Nord-Pas-de-Calais regional pharmacovigilance center between 2010 and 2012. The opinion of the regional pharmacovigilance centre was held on the record of the adverse drug reaction in the national pharmacovigilance database and analyzed according to the conclusion of iatrogenic used by clinicians in internal medicine (reference diagnosis) with a follow-up to June 2013. The variables relating to the patient, medication and adverse events were analyzed by binary logistic regression. We analyzed 160 contacts: 118 concordant cases, 38 false-positives (drug-related side effect retained by the regional pharmacovigilance center only), 4 false negatives. Registration in the national pharmacovigilance database had a sensitivity of 96% (95% CI [0.92 to 0.99]), a specificity of 46% (95% CI [0.38 to 0.53]), a value positive predictive of 69% (95% CI [0.62 to 0.76]), a negative predictive value of 89% (95% CI [0.84 to 0.94]) and a negative likelihood ratio of 0.1. False-positive had chronological and semiological accountabilities questionable (adjusted RR=2.1, 95% CI [1.2 to 2.8]). In our study, the regional pharmacovigilance center confirms the clinician's suspicion of drug-related side effects and helps to exclude drug-induced with a high negative predictive value. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  19. International consensus diagnostic criteria for neuromyelitis optica spectrum disorders

    Science.gov (United States)

    Banwell, Brenda; Bennett, Jeffrey L.; Cabre, Philippe; Carroll, William; Chitnis, Tanuja; de Seze, Jérôme; Fujihara, Kazuo; Greenberg, Benjamin; Jacob, Anu; Jarius, Sven; Lana-Peixoto, Marco; Levy, Michael; Simon, Jack H.; Tenembaum, Silvia; Traboulsee, Anthony L.; Waters, Patrick; Wellik, Kay E.

    2015-01-01

    Neuromyelitis optica (NMO) is an inflammatory CNS syndrome distinct from multiple sclerosis (MS) that is associated with serum aquaporin-4 immunoglobulin G antibodies (AQP4-IgG). Prior NMO diagnostic criteria required optic nerve and spinal cord involvement but more restricted or more extensive CNS involvement may occur. The International Panel for NMO Diagnosis (IPND) was convened to develop revised diagnostic criteria using systematic literature reviews and electronic surveys to facilitate consensus. The new nomenclature defines the unifying term NMO spectrum disorders (NMOSD), which is stratified further by serologic testing (NMOSD with or without AQP4-IgG). The core clinical characteristics required for patients with NMOSD with AQP4-IgG include clinical syndromes or MRI findings related to optic nerve, spinal cord, area postrema, other brainstem, diencephalic, or cerebral presentations. More stringent clinical criteria, with additional neuroimaging findings, are required for diagnosis of NMOSD without AQP4-IgG or when serologic testing is unavailable. The IPND also proposed validation strategies and achieved consensus on pediatric NMOSD diagnosis and the concepts of monophasic NMOSD and opticospinal MS. PMID:26092914

  20. Molecular Diagnostics of the Internal Structure of Starspots and Sunspots

    Science.gov (United States)

    Afram, N.; Berdyugina, S. V.; Fluri, D. M.; Solanki, S. K.; Lagg, A.; Petit, P.; Arnaud, J.

    2006-12-01

    We have analyzed the usefulness of molecules as a diagnostic tool for studying solar and stellar magnetism with the molecular Zeeman and Paschen-Back effects. In the first part we concentrate on molecules that are observed in sunspots such as MgH and TiO. We present calculated molecular line profiles obtained by assuming magnetic fields of 2-3 kG and compare these synthetic Stokes profiles with spectro-polarimetric observations in sunspots. The good agreement between the theory and observations allows us to turn our attention in the second part to starspots to gain insight into their internal structure. We investigate the temperature range in which the selected molecules can serve as indicators for magnetic fields on highly active cool stars and compare synthetic Stokes profiles with our recent observations.

  1. Development of transient internal probe (TIP) magnetic field diagnostic

    International Nuclear Information System (INIS)

    Galambos, J.P.; Bohnet, M.A.; Jarboe, T.R.; Mattick, A.T.

    1994-01-01

    The Transient Internal Probe (TIP) is designed to permit measurement of internal magnetic fields, in hot, high density plasmas. The concept consists of accelerating a probe to high velocities (2.2 Km/s) in order to minimize probe exposure time to plasma. Faraday rotation within the probe is used to measure the local magnetic field. An Argon laser illuminates the probe consisting of a Faraday-rotator material with a retro-reflector that returns the incident light to the detection system. Performance results of the light gas gun and optical detection system will be shown. To date, the gas gun has been extensively tested consistently achieving velocities between 2 and 3 km/s. The probe and detection scheme have been tested by dropping the probe through a static magnetic field. Magnetic field resolution of 20 gauss and spatial resolution of 5 mm has been achieved. System frequency response is 10Mhz. Work is currently being conducted to integrate the diagnostic system with laboratory plasma experiments. Specifically a gas interfaced system has been developed to prevent helium muzzle gas from entering the plasma chamber with the probe. Additionally the probe must be separated from the sabot which protects the probe during acceleration in the gas gun. Data will be presented showing the results of various separation techniques

  2. Atomic structures and compositions of internal interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Seidman, D.N. (Northwestern Univ., Evanston, IL (United States). Dept. of Materials Science and Engineering); Merkle, K.L. (Argonne National Lab., IL (United States))

    1992-03-01

    This research program addresses fundamental questions concerning the relationships between atomic structures and chemical compositions of metal/ceramic heterophase interfaces. The chemical composition profile across a Cu/MgO {l brace}111{r brace}-type heterophase interface, produced by the internal oxidation of a Cu(Mg) single phase alloy, is measured via atom-probe field-ion microscopy with a spatial resolution of 0.121 nm; this resolution is equal to the interplanar space of the {l brace}222{r brace} MgO planes. In particular, we demonstrate for the first time that the bonding across a Cu/MgO {l brace}111{r brace}-type heterophase interface, along a <111> direction common to both the Cu matrix and an MgO precipitate, has the sequence Cu{vert bar}O{vert bar}Mg{hor ellipsis} and not Cu{vert bar}Mg{vert bar}O{hor ellipsis}; this result is achieved without any deconvolution of the experimental data. Before determining this chemical sequence it was established, via high resolution electron microscopy, that the morphology of an MgO precipitate in a Cu matrix is an octahedron faceted on {l brace}111{r brace} planes with a cube-on-cube relationship between a precipitate and the matrix. First results are also presented for the Ni/Cr{sub 2}O{sub 4} interface; for this system selected area atom probe microscopy was used to analyze this interface; Cr{sub 2}O{sub 4} precipitates are located in a field-ion microscope tip and a precipitate is brought into the tip region via a highly controlled electropolishing technique.

  3. The European Union CREATE project: a model for international standardization of allergy diagnostics and vaccines

    NARCIS (Netherlands)

    Chapman, Martin D.; Ferreira, Fatima; Villalba, Mayte; Cromwell, Oliver; Bryan, Donna; Becker, Wolf-Meinhard; Fernández-Rivas, Montserrat; Durham, Stephen; Vieths, Stefan; van Ree, Ronald; Aalbers, M.; Notten, S.; Ooievaar-de Heer, P.; Ferreira, F.; Gademaier, G.; Wallner, M.; Villalba, M.; Rodriguez, R.; Becker, W.-M.; Eberhardt, F.; Lepp, U.; Raulf-Heimsoth, M.; Valenta, R.; Focke, M.; Bryan, D.; Dolman, C.; Das, R. G.; Vieths, S.; Fötisch, K.; Di Felice, G.; Pini, C.; Cromwell, O.; Fiebig, H.; Weber, B.; van Schijndel, H.; Dorpema, J. W.; Marco, F. M.; Monsalve, R.; Barber, D.; Caldas, E. Fernandez; Moingeon, P.; Didierlaurent, A.; André, C.; Kroon, A.; Neubauer, A.; Chapman, M.; Vailes, L.; Tsay, A.; Durham, S.; Custovic, A.; Simpson, B.; Knulst, A.; Rivas, M. Fernández; Mancebo, E. Gonzalez; Bahima, A. Cistero; Moncin, M. M. San Miguel; Mari, A.; Kinaciyan, T.; Quiralte, J.; Pauli, G.; de Blay, F.; Purohit, A.; Rak, S.

    2008-01-01

    Allergen measurements are used extensively in the formulation of allergy diagnostics and vaccines, yet no purified international allergen standards are available for calibration purposes. The aims of the European Union CREATE project were to develop international standards with verifiable allergen

  4. Micromechanical Models for Composite NDE and Diagnostics, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Modern aircraft (and next generation spacecraft) increasingly rely on composite components due to their excellent specific strength and stiffness, as well as...

  5. CLASSIFICATION OF TEMPOROMANDIBULAR-JOINT OSTEOARTHROSIS AND INTERNAL DERANGEMENT .2. SPECIFIC DIAGNOSTIC-CRITERIA

    NARCIS (Netherlands)

    STEGENGA, B; DEBONT, LGM; BOERING, G

    Separate entities of temporomandibular joint osteoarthrosis and internal derangement are operationally defined. Criteria are based on an analysis of the diagnostic significance of symptoms and signs, principles of synovial joint pathology in general, and on therapeutic considerations. The primary

  6. Perception Of Trader Towards International Trade: A Diagnostic Study

    Directory of Open Access Journals (Sweden)

    Muzaffar Asad

    2010-12-01

    Full Text Available In this article the authors have identified the significant factors that influence international trade in the light of traders. Foreign exchange transaction may prove to be helpful in managing currency risk which is associated with import and export of goods. The significance of multi-national firms over international trade has been discussed along with the impact of balance of payment over international trade and the measures taken by the government to create a balance in balance of payment and balance of trade. The considerations of countries while determining exchange rates have been elaborated in this paper. The numerous factors that affect decision making for International Traders and the rectifications are also discussed in this paper. The paper also discusses how various aspects induce an industry to change its course or completely shut down and how to deal with these lingering threats. On the basis of literature reviewed the variables that have been selected that may influence international trade include; trade quotas, brand name, WTO, NAFTA, SAFTA, ASIAN, GATT, e-commerce, international payment systems, product specialization, home industry, foreign reserves, government regulations, international market, dumping duties, trade policies, social crises, economic crises, balance of payments, change in value, and supply than demand. A questionnaire will be developed on the basis of above-mentioned variables. The respondents of questionnaire will be the traders in the international market, importers and exporters. The data will then be handled by the use of SPSS. Regression analysis will be conducted to identify the significant variables that have major impact on international trade. At the end the recommendations will be mentioned for getting maximum benefit from international trade.

  7. Nuclear magnetic resonance in diagnostics of internal diseases

    International Nuclear Information System (INIS)

    Malaya, L.T.; Uvarov, N.I.; Shashura, Yu.V.; Miklyaev, I.Yu.; Zhmuro, A.V.

    1990-01-01

    Use of NMR-tomography in general and differential diagnosis of brain diseases, diseases of internal organs (liver, galbludder, pancreas, kidneys, adrenal glands, organs small pelvis, thoracic cavity, soft tissues and bone-jopint system) is shown. Physical-technical bases of getting NMR image are presented. Problems of reproducibility, accuracy and interpretation of investigation results are discussed. 253 refs.; 1 tab

  8. Improved Internal Reference Oxygen Sensors with Composite Ceramic Electrodes

    DEFF Research Database (Denmark)

    Hu, Qiang; Jacobsen, Torben; Hansen, Karin Vels

    2012-01-01

    Potentiometric oxygen sensors with an internal reference electrode, which uses the equilibrium pO2 of the binary mixture of Ni/NiO as the reference, are demonstrated. The cells employ Pt or composite ceramics as the sensing electrode. The cells are fabricated by a flexible and potentially low cost...... and performance are highly reproducible. The composite ceramics, based on strontium doped manganite and yttria doped zirconia, are proven superior over Pt to serve as the electrode material....

  9. Elastic constants and internal friction of fiber-reinforced composites

    International Nuclear Information System (INIS)

    Ledbetter, H.M.

    1982-01-01

    We review recent experimental studies at NBS on the anisotropic elastic constants and internal friction of fiber-reinforced composites. Materials that were studied include: boron-aluminum, boron-epoxy, graphite-epoxy, glass-epoxy, and aramid-epoxy. In all cases, elastic-constant direction dependence could be described by relationships developed for single crystals of homogeneous materials. Elastic stiffness and internal friction were found to vary inversely

  10. International Reserves and the Composition of Equity Capital Inflows

    OpenAIRE

    Xingwang Qian; Andreas Steiner

    2012-01-01

    We study the effect of central banks' international reserve hoardings on the composition of equity capital inflows, namely the ratio of portfolio equity investment (PEI) to foreign direct investment (FDI). Foreign investors' decisions regarding the location and the type of equity capital investment might be influenced by a country's level of international reserves. In a simple theoretical model, we show that higher reserves, thanks to their ability to lower exchange rate risk, reduce the risk...

  11. Particle compositions with a pre-selected cell internalization mode

    Science.gov (United States)

    Decuzzi, Paolo (Inventor); Ferrari, Mauro (Inventor)

    2012-01-01

    A method of formulating a particle composition having a pre-selected cell internalization mode involves selecting a target cell having surface receptors and obtaining particles that have i) surface moieties, that have an affinity for or are capable of binding to the surface receptors of the cell and ii) a preselected shape, where a surface distribution of the surface moieties on the particles and the shape of the particles are effective for the pre-selected cell internalization mode.

  12. 6th International Workshop on Compositional Data Analysis

    CERN Document Server

    Thió-Henestrosa, Santiago

    2016-01-01

    The authoritative contributions gathered in this volume reflect the state of the art in compositional data analysis (CoDa). The respective chapters cover all aspects of CoDa, ranging from mathematical theory, statistical methods and techniques to its broad range of applications in geochemistry, the life sciences and other disciplines. The selected and peer-reviewed papers were originally presented at the 6th International Workshop on Compositional Data Analysis, CoDaWork 2015, held in L’Escala (Girona), Spain. Compositional data is defined as vectors of positive components and constant sum, and, more generally, all those vectors representing parts of a whole which only carry relative information. Examples of compositional data can be found in many different fields such as geology, chemistry, economics, medicine, ecology and sociology. As most of the classical statistical techniques are incoherent on compositions, in the 1980s John Aitchison proposed the log-ratio approach to CoDa. This became the foundation...

  13. Proceedings of the 13th international symposium on laser-aided plasma diagnostics

    International Nuclear Information System (INIS)

    Kawahata, Kazuo

    2007-09-01

    The 9th international symposium on LASER-AIDED PLASMA DIAGNOSTICS was held from 18th November to 21st September, 2007 at Takayama, Japan. This symposium was organized by the National Institute for Fusion Science, Toki, Japan. The topics of the symposium include laser diagnostics and diagnostics aided by lasers for fusion plasmas, industrial process plasmas, environmental plasmas as well as for other plasma applications and processes related to plasmas. Hardware development related to laser-aided plasma diagnostics is another topic. Over 80 participants attended this international symposium. 1 Akazaki lecture, 10 general talks, 10 topical talks, 12 short oral talks and 45 posters were presented. This issue is the collection of the papers presented at the title symposium. The 41 of the presented papers are indexed individually. (J.P.N.)

  14. Transforming Internal Activities of Business Process Models to Services Compositions

    NARCIS (Netherlands)

    Dirgahayu, Teduh; Quartel, Dick; van Sinderen, Marten J.; Mostefaoui, S.K.; Maamar, Z.; Ferreira Pires, L.; Hammoudi, S.; Rinderle-Ma, S.; Sadiq, S.; Schulz, K.

    As a service composition language, BPEL imposes as constraint that a business process model should consist only of activities for interacting with other business processes. BPEL provides limited support for implementing internal activities, i.e. activities that are performed by a single business

  15. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  16. Molecular Diagnostics of the Internal Motions of Massive Cores

    Science.gov (United States)

    Pineda, Jorge; Velusamy, T.; Goldsmith, P.; Li, D.; Peng, R.; Langer, W.

    2009-12-01

    We present models of the internal kinematics of massive cores in the Orion molecular cloud. We use a sample of cores studied by Velusamy et al. (2008) that show red, blue, and no asymmetry in their HCO+ line profiles in equal proportion, and which therefore may represent a sample of cores in different kinematic states. We use the radiative transfer code RATRAN (Hogerheijde & van der Tak 2000) to model several transitions of HCO+ and H13CO+ as well as the dust continuum emission, of a spherical model cloud with radial density, temperature, and velocity gradients. We find that an excitation and velocity gradients are prerequisites to reproduce the observed line profiles. We use the dust continuum emission to constrain the density and temperature gradients. This allows us to narrow down the functional forms of the velocity gradient giving us the opportunity to test several theoretical predictions of velocity gradients produced by the effect of magnetic fields (e.g. Tassis et. al. 2007) and turbulence (e.g. Vasquez-Semanedi et al 2007).

  17. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray Departments, four draft standards on specific topics, seven more documents are in advanced stage, and several others under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform tests and interpret results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standards produced so far, with emphasis on physical parameters of diagnostic X-ray installations and proposed criteria for satisfactory performance. (author)

  18. International veterinary epilepsy task force consensus proposal : diagnostic approach to epilepsy in dogs

    NARCIS (Netherlands)

    De Risio, Luisa; Bhatti, Sofie; Muñana, Karen; Penderis, Jacques; Stein, Veronika; Tipold, Andrea; Berendt, Mette; Farqhuar, Robyn; Fischer, Andrea; Long, Sam; Mandigers, Paul J J; Matiasek, Kaspar; Packer, Rowena M A; Pakozdy, Akos; Patterson, Ned; Platt, Simon; Podell, Michael; Potschka, Heidrun; Batlle, Martí Pumarola; Rusbridge, Clare; Volk, Holger A

    2015-01-01

    This article outlines the consensus proposal on diagnosis of epilepsy in dogs by the International Veterinary Epilepsy Task Force. The aim of this consensus proposal is to improve consistency in the diagnosis of epilepsy in the clinical and research settings. The diagnostic approach to the patient

  19. Antenna design for fast ion collective Thomson scattering diagnostic for the international thermonuclear experimental reactor

    DEFF Research Database (Denmark)

    Leipold, Frank; Furtula, Vedran; Salewski, Mirko

    2009-01-01

    Fast ion physics will play an important role for the international thermonuclear experimental reactor (ITER), where confined alpha particles will affect and be affected by plasma dynamics and thereby have impacts on the overall confinement. A fast ion collective Thomson scattering (CTS) diagnostic...

  20. The Absolute Deviation Rank Diagnostic Approach to Gear Tooth Composite Fault

    Directory of Open Access Journals (Sweden)

    Guangbin Wang

    2017-01-01

    Full Text Available Aiming at nonlinear and nonstationary characteristics of the different degree with single fault gear tooth broken, pitting, and composite fault gear tooth broken-pitting, a method for the diagnosis of absolute deviation of gear faults is presented. The method uses ADAMS, respectively, set-up dynamics model of single fault gear tooth broken, pitting, and composite fault gear tooth broken-pitting, to obtain the result of different degree of broken teeth, pitting the single fault and compound faults in the meshing frequency, and the amplitude frequency doubling through simulating analysis. Through the comparison with the normal state to obtain the sensitive characteristic of the fault, the absolute value deviation diagnostic approach is used to identify the fault and validate it through experiments. The results show that absolute deviation rank diagnostic approach can realize the recognition of gear single faults and compound faults with different degrees and provide quick reference to determine the degree of gear fault.

  1. 7th international symposium on internal combustion diagnostics. Proceedings; 7. Internationales Symposium fuer Verbrennungsdiagnostik. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    At one time combustion pressure indicating was the ''trigger'' for this symposium, and today it still serves as the basis for continued investigation of combustion phenomena. It now finds application throughout the development process, as more sophisticated analysis of conventional signals is possible. Understanding of localized combustion phenomena is substantially simplified by means of optical diagnostic methods, the application of which has reached a certain level of standardization. The presentations will cover specific topics including fuel spray analysis, ignition events and information about gas mixtures. The comparison and combination of results from measurement and simulation shed light on the complex processes in the combustion chamber. What's more, the linkage of two complementary methods offers substantial cost savings through reductions in test hardware and shorter development times. Focused application of all of the available tools allows us better to understand combustion processes, recognize the influential parameters and derive control algorithms. The latter are subsequently to be found in engines that fulfill both regulatory requirements and customer expectations. So it is that the symposium captures the current state of the art in combustion diagnostics through a combination of indicating, optical diagnostics and simulation, and offers both the methodology expert and the engine developer the ideal platform for discussion of today's issues - and to form their own opinions on them. Anyone wanting to keep up to date in this continuously developing and ever more complex area of activity certainly can't afford to miss our symposium. (orig.)

  2. A study on the fault diagnostic techniques for reactor internal structures using neutron noise analysis

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Jeong, Seong Ho; Park, Jin Ho; Park, Jin Suk

    1994-08-01

    The unfavorable phenomena, such as flow induced vibration and aging process in reactor internals, cause degradation of structural integrity and may result in loosing some mechanical binding components which might impact other equipments and components or cause flow blockage. Since these malfunctions and potential failures change reactor noise signal, it is necessary to analyze reactor noise signal for early fault diagnosis in the point of few of safety and plant economics. The objectives of this study are to establish fault diagnostic and TS(thermal shield), and to develop a data acquisition and signal processing software system. In the first year of this study, an analysis technique for the reactor internal vibration using the reactor noise was proposed. With the technique proposed and the reactor noise signals (ex-core neutron and acceleration), the dynamic characteristics of Ulchin-1 reactor internals were obtained, and compared with those of Tricastin-1 which is the prototype of Ulchin-1. In the second year, a PC-based expert system for reactor internals fault diagnosis is developed, which included data acquisition, signal processing, feature extraction function, and represented diagnostic knowledge by the IF-THEN rule. To know the effect of the faults, the reactor internals of Ulchin-1 is modeled using FEM and simulated with an artificial defect given in the hold-down spring. Trend in the dynamic characteristics of reactor internals is also observed during one fuel cycle to know the effect of boron concentration. 100 figs, 7 tabs, 18 refs. (Author)

  3. Application of neural networks and neutron noise for diagnostics of reactor internals vibration

    International Nuclear Information System (INIS)

    Garis, N.S.; Pazsit, I.; Gloeckler, O.

    1995-01-01

    It has long been known that vibration of reactor internals, in particular excessive vibrations of control rods, can be detected via the neutron noise they induce. Noise measurements are actually suitable to determine important diagnostic parameters such as the location of the vibrating rod and the vibration amplitude. An algorithm was earlier elaborated for this purpose, which is based on inversion of the expression describing the neutron noise as a function of vibration parameters. This inversion procedure is nevertheless complicated and not always unique. It was investigated whether a properly trained neural network can perform the inversion more effectively. It was found that artificial neural networks can be trained effectively to perform vibration diagnostics from neutron noise data fast, effectively and reliably. The present paper gives a description of the development and use of the neural networks for purposes of vibration diagnostics

  4. 7th international symposium on internal combustion diagnostics. Proceedings; 7. Internationales Symposium fuer Verbrennungsdiagnostik. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    At one time combustion pressure indicating was the ''trigger'' for this symposium, and today it still serves as the basis for continued investigation of combustion phenomena. It now finds application throughout the development process, as more sophisticated analysis of conventional signals is possible. Understanding of localized combustion phenomena is substantially simplified by means of optical diagnostic methods, the application of which has reached a certain level of standardization. The presentations will cover specific topics including fuel spray analysis, ignition events and information about gas mixtures. The comparison and combination of results from measurement and simulation shed light on the complex processes in the combustion chamber. What's more, the linkage of two complementary methods offers substantial cost savings through reductions in test hardware and shorter development times. Focused application of all of the available tools allows us better to understand combustion processes, recognize the influential parameters and derive control algorithms. The latter are subsequently to be found in engines that fulfill both regulatory requirements and customer expectations. So it is that the symposium captures the current state of the art in combustion diagnostics through a combination of indicating, optical diagnostics and simulation, and offers both the methodology expert and the engine developer the ideal platform for discussion of today's issues - and to form their own opinions on them. Anyone wanting to keep up to date in this continuously developing and ever more complex area of activity certainly can't afford to miss our symposium. (orig.)

  5. Improved Internal Reference Oxygen Sensors Using Composite Oxides as Electrodes

    DEFF Research Database (Denmark)

    Hu, Qiang

    The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75S...... the application of IROSes are provided. Based on the concepts and fundamentals of the IROS, internal reference sensors that detect other gas species such as hydrogen, chlorine and bromine may be developed.......The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75Sr0...... from 8YSZ is evaluated quantitatively and figures that may be used to design the depletion period of an IROS due to the electronic leak of 8YSZ are provided. One dimensional numerical simulations are performed to study the variation in cell voltage during the process of gas mixing, and the asymmetric...

  6. A Piezoelectroluminescent Fiber-Optical Sensor for Diagnostics of the 3D Stress State in Composite Structures

    Science.gov (United States)

    Pan'kov, A. A.

    2018-05-01

    The mathematical model of a piezoelectroluminescent fiber-optical sensor is developed for diagnostics of the 3D stress state of composite structures. The sensor model is a coaxial sector-compound layered cylinder consisting of a central optical fiber with electroluminescent and piezoelectric layers and an external uniform elastic buffer layer. The electroluminescent and piezoelectric layers are separated by radial-longitudinal boundaries, common for both layers, into geometrically equal six "measuring elements" — cylindrical two-layered sectors. The directions of 3D polarization of the piezoelectric phases and the frequencies of luminous efficacy of the electroluminescent phases are different in each sector. In the sensor, a thin translucent "internal" controlling electrode is located between the optical fiber and the electroluminescent layer, and the piezoelectric layer is coated by a thin "external" controlling electrode. The results of numerical modeling of the nonuniform coupled electroelastic fields of the piezoelectroluminescent fiber-optical sensor in the loaded "representative volume" of a composite, taking into account the action of the controlling voltage on the internal and external electrodes, of a numerical calculation of "informative and controlling coefficients" of the sensor, and of testing of an arbitrary 3D stress of state of a unidirectional glass-fiber plastic by the finite-element method are presented.

  7. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group (WG 10) to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray installations. Since then, the working group has produced a report on General Aspects of Quality Assurance in Diagnostic X-ray Departments and four draft standards on specific topics, while seven more documents are in advanced drafting stage. Several others are presently under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform the tests and interpret their results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standard produced so far, with emphasis on the physical parameters of diagnostic X-ray installations and their proposed criteria for satisfactory performance. (author)

  8. A new asteroseismic diagnostic for internal rotation in γ Doradus stars

    DEFF Research Database (Denmark)

    Ouazzani, Rhita-Maria; Salmon, S. J. A. J.; Antoci, V.

    2017-01-01

    to rotation. In this paper, we define a new seismic diagnostic for rotation in γ Doradus stars which are too rapidly rotating to present rotational splittings. Based on the non-uniformity of their period spacings, we define the observable Σ as the slope of the period spacing when plotted as a function......With four years of nearly continuous photometry from Kepler, we are finally in a good position to apply asteroseismology to γ Doradus stars. In particular, several analyses have demonstrated the possibility to detect non-uniform period spacings, which have been predicted to be directly related...... of period. We provide a one-to-one relation between this observable Σ and the internal rotation, which applies widely in the instability strip of γ Doradus stars. We apply the diagnostic to a handful of stars observed by Kepler. Thanks to g modes in γ Doradus stars, we are now able to determine the internal...

  9. Internal friction in a new kind of metal matrix composites

    International Nuclear Information System (INIS)

    San Juan, J.; No, M.L.

    2006-01-01

    We have developed a new kind of metal matrix composites, based on powders of Cu-Al-Ni shape memory alloys (SMAs) surrounded by an indium matrix, specifically designed to exhibit high mechanical damping. The damping properties have been characterized by mechanical spectroscopy as a function of temperature between 150 and 400 K, frequency between 3 x 10 -3 and 3 Hz, and strain amplitude between 5 x 10 -6 and 10 -4 . The material exhibits, in some range of temperature, internal friction as high as 0.54. The extremely high damping is discussed in the light of the microstructure of the material, which has been characterized in parallel

  10. International consensus for neuroblastoma molecular diagnostics: report from the International Neuroblastoma Risk Group (INRG) Biology Committee

    Science.gov (United States)

    Ambros, P F; Ambros, I M; Brodeur, G M; Haber, M; Khan, J; Nakagawara, A; Schleiermacher, G; Speleman, F; Spitz, R; London, W B; Cohn, S L; Pearson, A D J; Maris, J M

    2009-01-01

    Neuroblastoma serves as a paradigm for utilising tumour genomic data for determining patient prognosis and treatment allocation. However, before the establishment of the International Neuroblastoma Risk Group (INRG) Task Force in 2004, international consensus on markers, methodology, and data interpretation did not exist, compromising the reliability of decisive genetic markers and inhibiting translational research efforts. The objectives of the INRG Biology Committee were to identify highly prognostic genetic aberrations to be included in the new INRG risk classification schema and to develop precise definitions, decisive biomarkers, and technique standardisation. The review of the INRG database (n=8800 patients) by the INRG Task Force finally enabled the identification of the most significant neuroblastoma biomarkers. In addition, the Biology Committee compared the standard operating procedures of different cooperative groups to arrive at international consensus for methodology, nomenclature, and future directions. Consensus was reached to include MYCN status, 11q23 allelic status, and ploidy in the INRG classification system on the basis of an evidence-based review of the INRG database. Standardised operating procedures for analysing these genetic factors were adopted, and criteria for proper nomenclature were developed. Neuroblastoma treatment planning is highly dependant on tumour cell genomic features, and it is likely that a comprehensive panel of DNA-based biomarkers will be used in future risk assignment algorithms applying genome-wide techniques. Consensus on methodology and interpretation is essential for uniform INRG classification and will greatly facilitate international and cooperative clinical and translational research studies. PMID:19401703

  11. A composite peripheral blood gene expression measure as a potential diagnostic biomarker in bipolar disorder

    DEFF Research Database (Denmark)

    Munkholm, Klaus; Peijs, L; Vinberg, M

    2015-01-01

    as a diagnostic and state biomarker in bipolar disorder. First, messenger RNA levels of 19 candidate genes were assessed in peripheral blood mononuclear cells of 37 rapid cycling bipolar disorder patients in different affective states (depression, mania and euthymia) during a 6-12-month period and in 40 age...... subjects. In patients with bipolar disorder, upregulation of NDUFV2 was observed in a depressed state compared with a euthymic state. The composite gene expression measure for discrimination between patients and healthy control subjects on the basis of 19 genes generated an area under the receiver...

  12. PREFACE: International Conference on Structural Nano Composites (NANOSTRUC 2012)

    Science.gov (United States)

    Njuguna, James

    2012-09-01

    Dear Colleagues It is a great pleasure to welcome you to NanoStruc2012 at Cranfield University. The purpose of the 2012 International Conference on Structural Nano Composites (NanoStruc2012) is to promote activities in various areas of materials and structures by providing a forum for exchange of ideas, presentation of technical achievements and discussion of future directions. NanoStruc brings together an international community of experts to discuss the state-of-the-art, new research results, perspectives of future developments, and innovative applications relevant to structural materials, engineering structures, nanocomposites, modelling and simulations, and their related application areas. The conference is split in 7 panel sessions, Metallic Nanocomposites and Coatings, Silica based Nanocomposites, safty of Nanomaterials, Carboin based Nanocomposites, Multscale Modelling, Bio materials and Application of Nanomaterials. All accepted Papers will be published in the IOP Conference Series: Materials Science and Engineering (MSE), and included in the NanoStruc online digital library. The abstracts will be indexed in Scopus, Compedex, Inspec, INIS (International Nuclear Information System), Chemical Abstracts, NASA Astrophysics Data System and Polymer Library. Before ending this message, I would like to acknowledge the hard work, professional skills and efficiency of the team which ensured the general organisation. As a conclusion, I would like to Welcome you to the Nanostruc2012 and wish you a stimulating Conference and a wonderful time. On behalf of the scientific committee, Signature James Njuguna Conference Chair The PDF of this preface also contains committee listings and associates logos.

  13. Qualitative Event-Based Diagnosis: Case Study on the Second International Diagnostic Competition

    Science.gov (United States)

    Daigle, Matthew; Roychoudhury, Indranil

    2010-01-01

    We describe a diagnosis algorithm entered into the Second International Diagnostic Competition. We focus on the first diagnostic problem of the industrial track of the competition in which a diagnosis algorithm must detect, isolate, and identify faults in an electrical power distribution testbed and provide corresponding recovery recommendations. The diagnosis algorithm embodies a model-based approach, centered around qualitative event-based fault isolation. Faults produce deviations in measured values from model-predicted values. The sequence of these deviations is matched to those predicted by the model in order to isolate faults. We augment this approach with model-based fault identification, which determines fault parameters and helps to further isolate faults. We describe the diagnosis approach, provide diagnosis results from running the algorithm on provided example scenarios, and discuss the issues faced, and lessons learned, from implementing the approach

  14. Exhaust Gas Temperature Measurements in Diagnostics of Turbocharged Marine Internal Combustion Engines Part I Standard Measurements

    Directory of Open Access Journals (Sweden)

    Korczewski Zbigniew

    2015-01-01

    Full Text Available The article discusses the problem of diagnostic informativeness of exhaust gas temperature measurements in turbocharged marine internal combustion engines. Theoretical principles of the process of exhaust gas flow in turbocharger inlet channels are analysed in its dynamic and energetic aspects. Diagnostic parameters are defined which enable to formulate general evaluation of technical condition of the engine based on standard online measurements of the exhaust gas temperature. A proposal is made to extend the parametric methods of diagnosing workspaces in turbocharged marine engines by analysing time-histories of enthalpy changes of the exhaust gas flowing to the turbocompressor turbine. Such a time-history can be worked out based on dynamic measurements of the exhaust gas temperature, performed using a specially designed sheathed thermocouple.

  15. Sample Stability and Protein Composition of Saliva: Implications for Its Use as a Diagnostic Fluid

    Directory of Open Access Journals (Sweden)

    Han Roelofsen

    2008-01-01

    Full Text Available Saliva is an easy accessible plasma ultra-filtrate. Therefore, saliva can be an attractive alternative to blood for measurement of diagnostic protein markers. Our aim was to determine stability and protein composition of saliva. Protein stability at room temperature was examined by incubating fresh whole saliva with and without inhibitors of proteases and bacterial metabolism followed by Surface Enhanced Laser Desorption/Ionization (SELDI analyses. Protein composition was determined by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE fractionation of saliva proteins followed by digestion of excised bands and identification by liquid chromatography tandem mass spectrometry (LC-MS/MS. Results show that rapid protein degradation occurs within 30 minutes after sample collection. Degradation starts already during collection. Protease inhibitors partly prevented degradation while inhibition of bacterial metabolism did not affect degradation. Three stable degradation products of 2937 Da, 3370 Da and 4132 Da were discovered which can be used as markers to monitor sample quality. Saliva proteome analyses revealed 218 proteins of which 84 can also be found in blood plasma. Based on a comparison with seven other proteomics studies on whole saliva we identified 83 new saliva proteins. We conclude that saliva is a promising diagnostic fl uid when precautions are taken towards protein breakdown.

  16. Biomimetic mineral-organic composite scaffolds with controlled internal architecture.

    Science.gov (United States)

    Manjubala, I; Woesz, Alexander; Pilz, Christine; Rumpler, Monika; Fratzl-Zelman, Nadja; Roschger, Paul; Stampfl, Juergen; Fratzl, Peter

    2005-12-01

    Bone and cartilage generation by three-dimensional scaffolds is one of the promising techniques in tissue engineering. One approach is to generate histologically and functionally normal tissue by delivering healthy cells in biocompatible scaffolds. These scaffolds provide the necessary support for cells to proliferate and maintain their differentiated function, and their architecture defines the ultimate shape. Rapid prototyping (RP) is a technology by which a complex 3-dimensional (3D) structure can be produced indirectly from computer aided design (CAD). The present study aims at developing a 3D organic-inorganic composite scaffold with defined internal architecture by a RP method utilizing a 3D printer to produce wax molds. The composite scaffolds consisting of chitosan and hydroxyapatite were prepared using soluble wax molds. The behaviour and response of MC3T3-E1 pre-osteoblast cells on the scaffolds was studied. During a culture period of two and three weeks, cell proliferation and in-growth were observed by phase contrast light microscopy, histological staining and electron microscopy. The Giemsa and Gömöri staining of the cells cultured on scaffolds showed that the cells proliferated not only on the surface, but also filled the micro pores of the scaffolds and produced extracellular matrix within the pores. The electron micrographs showed that the cells covering the surface of the struts were flattened and grew from the periphery into the middle region of the pores.

  17. Method for remote diagnostics of the internal structure of layered media

    International Nuclear Information System (INIS)

    Lychagov, V V; Kal'yanov, A L; Ryabukho, V P; Lyakin, D V

    2008-01-01

    The method of autocorrelation low coherence interferometry is proposed for diagnostics of inhomogeneities and the internal structure of layered technical and biological samples. In this method the low coherence optical field reflected from the layered sample is analysed by using a Michelson interferometer. Because the object is outside the interferometer, the distance between the interferometer and the object under study is not limited and thus the object can move during the measurements. Theoretical substantiation of the autocorrelation method for media with discrete and continuous optical structure modifications is presented. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

  18. Student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures

    International Nuclear Information System (INIS)

    Zhou, G. Z.; Wong, D. D.; Nguyen, L. K.; Mendelson, R. M.

    2010-01-01

    Full text: This study aims to evaluate medical student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures and to suggest how education could be improved. Fourth to sixth year medical students enrolled at a Western Australian university and interns from three teaching hospitals in Perth were recruited. Participants were asked to complete a questionnaire consisting of 26 questions on their background, knowledge of ionising radiation doses and learning preferences for future teaching on this subject. A total of 331 completed questionnaires were received (95.9%). Of the 17 questions assessing knowledge of ionising radiation, a mean score of 6.0 was obtained by respondents (95% CI 5.8-6.2). Up to 54.8% of respondents underestimated the radiation dose from commonly requested radiological procedures. Respondents (11.3 and 25.5%) incorrectly believed that ultrasound and MRI emit ionising radiation, respectively. Of the four subgroups of respondents, the intern doctor subgroup performed significantly better (mean score 6.9, P< 0.0001, 95% CI 6.5-7.3) than each of the three medical student subgroups. When asked for the preferred method of teaching for future radiation awareness, a combination of lectures, tutorials and workshops was preferred. This study has clearly shown that awareness of ionising radiation from diagnostic imaging is lacking among senior medical students and interns. The results highlight the need for improved education to minimise unnecessary exposure of patients and the community to radiation. Further studies are required to determine the most effective form of education.

  19. The Effects of Changing Membrane Compositions and Internal Electrolytes on the Respon of Potassium Ion Sensor

    OpenAIRE

    Ulianas, Alizar; Heng, Lee Yook

    2015-01-01

    A study on the changing of membrane compositions and internal solution towards the response potassium ion sensor was carried out. Potassium ion sensor based on photocured cross linking poly(n-butyl acrylate) membranes with varying composition of valinomycin (val), sodium tetrakis [3.5-bis(trifluoro-methyl) phenyl] borat (NaTFPB), types ion of internal solution were investigated. Effects of varying composition of val, NaTFPB, types and concentration of internal solution were observed on potass...

  20. Application of the new International Code of Practice for dosimetry in diagnostic radiology to conventional exams

    International Nuclear Information System (INIS)

    Martinez Gonzalez, A.; Cardenas Herrera, J.; Walwyn Salas, G.; Machado, A.; Mora Machado, R. de la

    2008-01-01

    Full text: During the recent years, a policy for updating and installation of the X-ray equipment, specialized as well as conventional, have been carrying out, in Cuba. Conventional equipment has reached almost the whole primary level. Considering this situation, the quality control programs and clinical dosimetry have become even more important. Regarding the last one, an International Code of Practice for Dosimetry in Diagnostic Radiology had been published by the International Atomic Energy Agency in order to been used as a guide and to standardize the methodologies used to evaluate the patient exposure in radiodiagnostic. Taken into consideration the above reasons, an assessment of the aforementioned code of practice was done in order to choose the most feasible methodology to implement in the country. The evaluation was performed considering the lack of dosimetric equipment and medical physicists in this practice, in the interests of increasing the measurements scope to a large number of services as well as to standardize the methodology on a national scale. The present work shows the results obtained from the application of the new code of practice to conventional radiology exams in some medical institutions. Out of 3 on patients measurements methodologies described in the code of practice, the one of measurement of the incident air kerma was chosen. This methodology allow to the physicist to focus on the diagnostic equipment tests and to delegate the collection of the patient and exposure parameters data to the technicians, which make the increased of the patient and diagnostic departments sample, possible. The measurements were carried out in 2 hospital of the capital. The exams involved in the assessments were thorax PA, lumbar spine AP and lumbar spine LAT. In every diagnostic service, 25 patients were chosen on each projection. The weight and height average of the patient sample were 68 kg and 167 cm respectively. In the assessment were considered only

  1. The International Registry on Hand and Composite Tissue Transplantation.

    Science.gov (United States)

    Petruzzo, Palmina; Lanzetta, Marco; Dubernard, Jean-Michel; Landin, Luis; Cavadas, Pedro; Margreiter, Raimund; Schneeberger, Stephan; Breidenbach, Warren; Kaufman, Christina; Jablecki, Jerzy; Schuind, Frédéric; Dumontier, Christian

    2010-12-27

    The International Registry on Hand and Composite Tissue Transplantation was founded in May 2002, and the analysis of all cases with follow-up information up to July 2010 is presented here. From September 1998 to July 2010, 49 hands (17 unilateral and 16 bilateral hand transplantations, including 1 case of bilateral arm transplantation) have been reported, for a total of 33 patients. They were 31 men and 2 women (median age 32 years). Time since hand loss ranged from 2 months to 34 years, and in 46% of cases, the level of amputation was at wrist. Immunosuppressive therapy included tacrolimus, mycophenolate mofetil, sirolimus, and steroids; polyclonal or monoclonal antibodies were used for induction. Topical immunosuppression was also used in several cases. Follow-up ranges from 1 month to 11 years. One patient died on day 65. Three patients transplanted in the Western countries have lost their graft, whereas until September 2009, seven hand grafts were removed for noncompliance to the immunosuppressive therapy in China. Eighty-five percent of recipients experienced at least one episode of acute rejection within the first year, and they were reversible when promptly treated. Side effects included opportunistic infections, metabolic complications, and malignancies. All patients developed protective sensibility, 90% of them developed tactile sensibility, and 82.3% also developed a discriminative sensibility. Motor recovery enabled patients to perform most daily activities. Hand transplantation is a complex procedure, and its success is based on patient's compliance and his or her careful evaluation before and after transplantation.

  2. Sequential fault diagnosis for mechatronics system using diagnostic hybrid bond graph and composite harmony search

    Directory of Open Access Journals (Sweden)

    Ming Yu

    2015-12-01

    Full Text Available This article proposes a sequential fault diagnosis method to handle asynchronous distinct faults using diagnostic hybrid bond graph and composite harmony search. The faults under consideration include fault mode, abrupt fault, and intermittent fault. The faults can occur in different time instances, which add to the difficulty of decision making for fault diagnosis. This is because the earlier occurred fault can exhibit fault symptom which masks the fault symptom of latter occurred fault. In order to solve this problem, a sequential identification algorithm is developed in which the identification task is reactivated based on two conditions. The first condition is that the latter occurred fault has at least one inconsistent coherence vector element which is consistent in coherence vector of the earlier occurred fault, and the second condition is that the existing fault coherence vector has the ability to hide other faults and the second-level residual exceeds the threshold. A new composite harmony search which is capable of handling continuous variables and binary variables simultaneously is proposed for identification purpose. Experiments on a mobile robot system are conducted to assess the proposed sequential fault diagnosis algorithm.

  3. MO-DE-204-00: International Symposium: Patient Dose Reduction in Diagnostic Radiology

    International Nuclear Information System (INIS)

    2016-01-01

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented. Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend

  4. MO-DE-204-00: International Symposium: Patient Dose Reduction in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented. Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend

  5. Vibration Diagnostics as an effective Tool for Testing Engines of Internal Combustion

    Directory of Open Access Journals (Sweden)

    Ferenc Dömötör

    2017-10-01

    Full Text Available There are several methods of automotive diagnostics used in services to detect a large variety of faults and damages of various parts of engines of internal combustion. Undoubtedly, they are effective, but they are simply unable to find all types of mechanical faults occurring during the operation. This is the reason why authors of this paper tried to use a special tool, which has been proven for years for detecting faults of rolling element bearing in rotating machinery. During their research, the authors tried to find valuable results by measuring vibration of various parts of engines. Three items were tested, a Diesel engine and two Otto motors. A large number of measurements have been taken at various speed, at different points, in different directions, with different parameter setup, etc. However, there was one setup which has been applied to all three engines. It is the measurement setup of vibration velocity, in the frequency range of 2 Hz-300 Hz. Valuable consequences have been found regarding the clogging of the air filters and the exhaust systems. As a conclusion the authors expressed their opinion, that, apart from the traditional diagnostic methods used in services, vibration measurements can also be useful, especially for detecting faults of rolling element bearings.

  6. A study to establish international diagnostic reference levels for paediatric computed tomography

    International Nuclear Information System (INIS)

    Vassileva, J.; Rehani, M.; Kostova-Lefterova, D.; Al-Naemi, H.M.; Al Suwaidi, J.S.; Arandjic, D.; Bashier, E.H.O.; Kodlulovich Renha, S.; El-Nachef, L.; Aguilar, J.G.; Gershan, V.; Gershkevitsh, E.; Gruppetta, E.; Hustuc, A.; Jauhari, A.; Hassan Kharita, Mohammad; Khelassi-Toutaoui, N.; Khosravi, H.R.; Khoury, H.; Kralik, I.; Mahere, S.; Mazuoliene, J.; Mora, P.; Muhogora, W.; Muthuvelu, P.; Nikodemova, D.; Novak, L.; Pallewatte, A.; Pekarovic, D.; Shaaban, M.; Shelly, E.; Stepanyan, K.; Thelsy, N.; Visrutaratna, P.; Zaman, A.

    2015-01-01

    The article reports results from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDI vol ) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: <1 y, >1-5 y, >5-10 y and >10-15 y. CTDI w , CTDI vol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75. percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDI vol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided. (authors)

  7. International quality assurance project in colorectal cancer-unifying diagnostic and histopathological evaluation.

    Science.gov (United States)

    Jannasch, O; Udelnow, A; Romano, G; Dziki, A; Pavalkis, D; Lippert, H; Mroczkowski, P

    2014-04-01

    Several European countries are undertaking quality control projects in colorectal cancer. These efforts have led to improvements in survival, but a comparison between different projects reveals questionable results. The aim of this study is the presentation of results from hospitals in three different European countries participating in the International Quality Assurance in Colorectal Cancer (IQACC) project. For this publication, patients with cancer of the colon or rectum treated in 2009 and 2010 and recorded in the IQACC (Germany, Poland and Italy) were analysed. The comparison included number of patients, age, preoperative diagnostics (CT of the abdomen and thorax, MRI, colonoscopy, ultrasound, tumour markers), surgical approach, metastasis, height of rectal cancer and histopathological examination of a specimen (T stage, N stage and MERCURY classification for rectum resection). For short-term outcomes, general complications, wound dehiscence, tumour-free status at discharge, anastomotic leakage and in-hospital mortality were analysed. A total of 12,691 patients (6,756 with colon cancer, 5,935 with rectal cancer) were included in the analysis. Preoperative diagnostics differed significantly between countries. For pT and pN stages, several quality differences could be demonstrated, including missing stages (colon cancer: pT 5.7-12.5 %, pN 2.5-11.0 %; rectal cancer: pT 1.1-5.6 %, pN 1.1-15.5 %). The most relevant differences for short-term outcomes in colon cancer were found in general complications (4.2-22.8 %) and tumour-free status at discharge (74.5-91.7 %). In-hospital deaths ranged between 2.5 and 4.3 % and did not show significant differences. For rectal cancer, the country with the highest percentage of tumours localised less than 4 cm from the anal verge (16.0 %) showed the lowest frequency of amputation (8.5 %). Outcome differences were found for general complications (3.2-18.8 %), anastomotic leakage (0-4.3 %) and tumour-free status at discharge (72

  8. Use of a perfume composition as a fuel for internal combustion engines

    NARCIS (Netherlands)

    2013-01-01

    The present invention relates to fuel compositions containing perfume fractions, that is to say compositions of fragrance materials, and to the use of such perfume fractions containing fuel compositions to provide a fuel for internal combustion engines and burners. According to the present fuel

  9. REMOTE DIAGNOSTICS OF TURNOUTS STATE ON TIMING AND SPECTRAL COMPOSITION IN CURRENT CURVE

    Directory of Open Access Journals (Sweden)

    S. Yu. Buryak

    2015-03-01

    Full Text Available Purpose. Development and implementation the points system diagnostics that would allow determining remotely the current state of turnout with all possible faults, gradual and sudden failures, damages, and in real time to report about their appearance. Methodology. State diagnostics on the values analysis of turnout main parameters is proposed to carry out with the help of a computer and analog-to-digital converter (ADC. Connecting measurements performance is advisable to produce to a shunt ammeter, installed in the working circuit of the point feed panel. ADC converts the analog signal of lost volts at the shunt into digital form and transmits it to a computer which stores the received data on its own recording medium for their further processing and storage. There is special software that is capable to reconnect signal and construct its temporal characteristic as well as decompose it on the spectral components. Using it one can analyze the obtained data, which allows diagnosing state of points upon change the nature, values and composition of the current curve. Findings. The computer diagnosis method was confirmed in practice for possible indications of problems that are associated with both the mechanical part of the turnout and the electrical part of it, while controlling parameters such as the amount of current normal transition, when working on frictions, the duration of the transition, properly adjusted headset and attachment points, the state of the motor. Originality. The use of computer technology in the diagnosis of the state of turnouts during their operation to monitor the current values of technical indicators, analysis and storage for all types of electric switches with different types of engines both DC and AC occurs through digitization and recording signal from measuring shunt of point feeder panel. Practical value. The proposed method enables timely, still in the early stages of defect parts, damages or failures of nodes

  10. An approach to local diagnostic reference levels (DRL's) in the context of national and international DRL's

    International Nuclear Information System (INIS)

    Rogers, A.T.

    2001-01-01

    In recent years there has been a greater focus on the management of patient doses. This effort has been driven by the realisation of both the increasing magnitude of patient doses and their variation both intra- and inter-nationally. Legislators and guidance-issuing bodies have developed the idea of 'Diagnostic Reference Levels' (DRL's). In particular, the European Union, in their Council Directive 97/43/Euratom, required Member States to develop DRL's. The UK Government, when consolidating this EU Directive into UK legislation, extended the concept of DRL's from a national to an employer level. However, the methodologies used for development of national and international DRL's do not translate to a local level and hence a new approach is required. This paper describes one particular approach made by a UK hospital to introduce 'Local DRL's' in such a manner as to aid the optimisation process. This approach utilises a dose index, based on the local patient population, which is monitored for trends. Any trend in patient dose triggers an investigation linked to the clinical audit system within the Clinical Radiology Department. It is the audit cycle that ensures a continuing move towards an optimised situation. Additional triggers may be employed such as large patient dose variations. (author)

  11. Image data compression in diagnostic imaging. International literature review and workflow recommendation

    International Nuclear Information System (INIS)

    Braunschweig, R.; Kaden, Ingmar; Schwarzer, J.; Sprengel, C.; Klose, K.

    2009-01-01

    Purpose: Today healthcare policy is based on effectiveness. Diagnostic imaging became a ''pace-setter'' due to amazing technical developments (e.g. multislice CT), extensive data volumes, and especially the well defined workflow-orientated scenarios on a local and (inter)national level. To make centralized networks sufficient, image data compression has been regarded as the key to a simple and secure solution. In February 2008 specialized working groups of the DRG held a consensus conference. They designed recommended data compression techniques and ratios. Material und methoden: The purpose of our paper is an international review of the literature of compression technologies, different imaging procedures (e.g. DR, CT etc.), and targets (abdomen, etc.) and to combine recommendations for compression ratios and techniques with different workflows. The studies were assigned to 4 different levels (0-3) according to the evidence. 51 studies were assigned to the highest level 3. Results: We recommend a compression factor of 1: 8 (excluding cranial scans 1:5). For workflow reasons data compression should be based on the modalities (CT, etc.). PACS-based compression is currently possible but fails to maximize workflow benefits. Only the modality-based scenarios achieve all benefits. (orig.)

  12. Image data compression in diagnostic imaging. International literature review and workflow recommendation

    Energy Technology Data Exchange (ETDEWEB)

    Braunschweig, R.; Kaden, Ingmar [Klinik fuer Bildgebende Diagnostik und Interventionsradiologie, BG-Kliniken Bergmannstrost Halle (Germany); Schwarzer, J.; Sprengel, C. [Dept. of Management Information System and Operations Research, Martin-Luther-Univ. Halle Wittenberg (Germany); Klose, K. [Medizinisches Zentrum fuer Radiologie, Philips-Univ. Marburg (Germany)

    2009-07-15

    Purpose: Today healthcare policy is based on effectiveness. Diagnostic imaging became a ''pace-setter'' due to amazing technical developments (e.g. multislice CT), extensive data volumes, and especially the well defined workflow-orientated scenarios on a local and (inter)national level. To make centralized networks sufficient, image data compression has been regarded as the key to a simple and secure solution. In February 2008 specialized working groups of the DRG held a consensus conference. They designed recommended data compression techniques and ratios. Material und methoden: The purpose of our paper is an international review of the literature of compression technologies, different imaging procedures (e.g. DR, CT etc.), and targets (abdomen, etc.) and to combine recommendations for compression ratios and techniques with different workflows. The studies were assigned to 4 different levels (0-3) according to the evidence. 51 studies were assigned to the highest level 3. Results: We recommend a compression factor of 1: 8 (excluding cranial scans 1:5). For workflow reasons data compression should be based on the modalities (CT, etc.). PACS-based compression is currently possible but fails to maximize workflow benefits. Only the modality-based scenarios achieve all benefits. (orig.)

  13. A clinical audit programme for diagnostic radiology: The Approach adopted by the international atomic energy agency

    International Nuclear Information System (INIS)

    Faulkner, K.; Jaervinen, H.; Butler, P.; McLean, I. D.; Pentecost, M.; Rickard, M.; Abdullah, B.

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  14. PREFACE: 25th International Congress on Condition Monitoring and Diagnostic Engineering (COMADEM 2012)

    Science.gov (United States)

    Ball, Andrew; Mishra, Rakesh; Gu, Fengshou; Rao, Raj B. K. N.

    2012-05-01

    The proactive multidisciplinary conceptual philosophy of Condition Monitoring and Diagnostic Engineering Management (COMADEM) was conceived and has been nurtured, developed and sustained since 1988. Since then, it is gratifying to note that the condition monitoring, diagnostic and prognostic community worldwide (representing industrialists, academics, research and development organizations, professional/private establishments and many hardware/software vending organizations) has warmly welcomed and supported this venture. As is evidenced, many have reaped (and are reaping) the benefits of COMADEM interdiscipline through continuous knowledge discovery, generation and dissemination. We are now proud to celebrate the 25th Annual Event (Silver Jubilee) in Huddersfield, the most beautiful part of the United Kingdom. The theme of this Congress is 'Sustained Prosperity through Proactive Monitoring, Diagnosis, Prognosis and Management'. This proceedings is enriched by contributions from many keynote experts representing many industry and academic establishments worldwide. Authors from more than 30 different countries have pooled their rich multidisciplinary up-to-date knowledge, in order to share their invaluable experience with the COMADEM community. In this proceedings, the readers will find more than 120 refereed papers encompassing a number of topical areas of interest relating to the theme of the congress. The proceedings of COMADEM 2012 will appear in the Open Access Journal of Physics: Conference Series (JPCS), which is part of the IOP Conference Series. All papers published in the IOP Conference Series are fully citable and upon publication will be free to download. We would like to express our deep gratitude to all the keynote speakers, authors, referees, exhibitors, Technical Co-Sponsoring Organizations, Gold Sponsors, IOP Publishers, COMADEM 2012 organizing committee members, delegates and many others on whom the success of this prestigious event depends

  15. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    Science.gov (United States)

    Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  16. How to Move Beyond the Diagnostic and Statistical Manual of Mental Disorders/International Classification of Diseases.

    Science.gov (United States)

    Schildkrout, Barbara

    2016-10-01

    A new nosology for mental disorders is needed as a basis for effective scientific inquiry. Diagnostic and Statistical Manual of Mental Disorders and International Classification of Diseases diagnoses are not natural, biological categories, and these diagnostic systems do not address mental phenomena that exist on a spectrum. Advances in neuroscience offer the hope of breakthroughs for diagnosing and treating major mental illness in the future. At present, a neuroscience-based understanding of brain/behavior relationships can reshape clinical thinking. Neuroscience literacy allows psychiatrists to formulate biologically informed psychological theories, to follow neuroscientific literature pertinent to psychiatry, and to embark on a path toward neurologically informed clinical thinking that can help move the field away from Diagnostic and Statistical Manual of Mental Disorders and International Classification of Diseases conceptualizations. Psychiatrists are urged to work toward attaining neuroscience literacy to prepare for and contribute to the development of a new nosology.

  17. Diagnostic strategy and timing of intervention in infected necrotizing pancreatitis: an international expert survey and case vignette study

    NARCIS (Netherlands)

    van Grinsven, J. (Janneke); S. van Brunschot (Sandra); P. Fockens (Paul); J. van Grinsven (Janneke); O.J. Bakker (Olaf ); van Santvoort, H.C. (Hjalmar C.); T.L. Bollen (Thomas); M.A. Boermeester (Marja); C.H.J. van Eijck (Casper); M.G. Besselink (Marc); M.J. Bruno (Marco); C.H. Dejong (Cees); K.D. Horvath (Karen); van Eijck, C.H. (Casper H.); H. van Goor (Harry); H.G. Gooszen (Hein); Horvath, K.D. (Karen D.); K.P. van Lienden (Krijn); Abdelhafez, M.; Andersson, R.; Andren-Sandberg, A.; Ashley, S.; M.C. van Baal (Mark); Baron, T.; C. Bassi (Claudio); Bradley, E.; M.W. Buchler (M.); V.C. Cappendijk; Carter, R.; Charnley, R.; Coelho, D.; Connor, S.; Dellinger, P.; C. Dervenis (Christos); J. Devière (J.); Doctor, N.; Dudeja, V.; En-qiang, M.; Escourrou, J.; Fagenholz, P.; Farkas, G.; Forsmark, C.; Freeman, M.; P.C. Freeny (Patrick); French, J.; H. Friess; Gardner, T.; Goetzinger, P.; J.W. Haveman; S. Hofker (Sijbrand); Imrie, C.; Isaji, S.; Isenmann, R.; E. Klar (Ernst); J.S. Laméris (Johan ); M. Lerch (M.); P. Lévy (Philippe); Lillemoe, K.; Löhr, M.; J. Mayerle (Julia); Mayumi, T.; Mittal, A.; Moessner, J.; Morgan, D.; K.J. Mortele (Koenraad); Nealon, W.; J.P. Neoptolemos (John); V.B. Nieuwenhuijs (Vincent); Nordback, I.; Olah, A.; K. Oppong (K.); Padbury, R.; Papachristou, G.; Parks, R.; J.-W. Poley (Jan-Werner); Radenkovic, D.; Raraty, M.; Rau, B.; V. Rebours (Vinciane); Rische, S.; Runzi, M.; Sainani, N.; Sarr, M.; Schaapherder, S.; S. Seewald (Stefan); Seifert, H.; Shimosegawa, T.; Silverman, S.; Singh, V.; Siriwardena, A.; Steinberg, W.; Sutton, R.; Takeda, K.; R. Timmer (Robin); Vege, S.; R.P. Voermans (Rogier); J.J. De Waele (Jan J.); Wang, C. (Ch.); Warshaw, A.; J. Werner (Jens Martin); B.L. Weusten (Bas); Whitcomb, D.; Wig, J.; Windsor, J.; Zyromski, N.

    2016-01-01

    textabstractBackground The optimal diagnostic strategy and timing of intervention in infected necrotizing pancreatitis is subject to debate. We performed a survey on these topics amongst a group of international expert pancreatologists. Methods An online survey including case vignettes was sent to

  18. Performance of Different Diagnostic Criteria for Familial Mediterranean Fever in Children with Periodic Fevers : Results from a Multicenter International Registry

    NARCIS (Netherlands)

    Demirkaya, Erkan; Saglam, Celal; Turker, Turker; Koné-Paut, Isabelle; Woo, Pat; Doglio, Matteo; Amaryan, Gayane; Frenkel, Joost; Uziel, Yosef; Insalaco, Antonella; Cantarini, Luca; Hofer, Michael; Boiu, Sorina; Duzova, Ali; Modesto, Consuelo; Bryant, Annette; Rigante, Donato; Papadopoulou-Alataki, Efimia; Guillaume-Czitrom, Severine; Kuemmerle-Deschner, Jasmine; Neven, Bénédicte; Lachmann, Helen; Martini, Alberto; Ruperto, Nicolino; Gattorno, Marco; Ozen, Seza

    2015-01-01

    OBJECTIVE: Our aims were to validate the pediatric diagnostic criteria in a large international registry and to compare them with the performance of previous criteria for the diagnosis of familial Mediterranean fever (FMF). METHODS: Pediatric patients with FMF from the Eurofever registry were used

  19. Diagnostic budget study of the internal variability in ensemble simulations of the Canadian RCM

    Energy Technology Data Exchange (ETDEWEB)

    Nikiema, Oumarou; Laprise, Rene [UQAM, Canadian Network for Regional Climate Modelling and Diagnostics, Centre ESCER, Departement des Sciences de la Terre et de l' Atmosphere, B.P. 8888, Montreal, QC (Canada)

    2011-06-15

    Due to the chaotic and nonlinear nature of the atmospheric dynamics, it is known that small differences in the initial conditions (IC) of models can grow and affect the simulation evolution. In this study, we perform a quantitative diagnostic budget calculation of the various diabatic and dynamical contributions to the time evolution and spatial distribution of internal variability (IV) in simulations with the nested Canadian Regional Climate Model. We establish prognostic budget equations of the IV for the potential temperature and the relative vorticity fields. For both of these variables, the IV equations present similar terms, notably terms relating to the transport of IV by ensemble-mean flow and to the covariance of fluctuations acting on the gradient of the ensemble-mean state. We show the skill of these equations to diagnose the IV that took place in an ensemble of 20 3-month (summer season) simulations that differed only in their IC. Our study suggests that the dominant terms responsible for the large increase of IV are either the covariance term involving the potential temperature fluctuations and diabatic heating fluctuations, or the covariance of inter-member fluctuations acting upon ensemble-mean gradients. Our results also show that, on average, the third-order terms are negligible, but they can become important when the IV is large. (orig.)

  20. Schistosoma real-time PCR as diagnostic tool for international travellers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Tannich, Egbert; Polman, Katja; Clerinx, Jan; Van Esbroeck, Marjan

    2012-10-01

    To evaluate the use of a genus-specific PCR that combines high sensitivity with the detection of different Schistosoma species for diagnosis in international travellers and migrants in comparison to standard microscopy. The genus-specific real-time PCR was developed to target the 28S ribosomal RNA gene of the major human Schistosoma species. It was validated for analytical specificity and reproducibility and demonstrated an analytical sensitivity of 0.2 eggs per gram of faeces. Its diagnostic performance was further evaluated on 152 faecal, 32 urine and 38 serum samples from patients presenting at the outpatient clinic of the Institute of Tropical Medicine in Antwerp (Belgium). We detected Schistosoma DNA in 76 faecal (50.0%) and five urine (15.6%) samples of which, respectively, nine and one were not detected by standard microscopy. Only two of the 38 serum samples of patients with confirmed schistosomiasis were positive with the presently developed PCR. Sequence analysis on positive faecal samples allowed identification of the Schistosoma species complex. The real-time PCR is highly sensitive and may offer added value in diagnosing imported schistosomiasis. The genus-specific PCR can detect all schistosome species that are infectious to humans and performs very well with faeces and urine, but not in serum. © 2012 Blackwell Publishing Ltd.

  1. International conference on composite materials and energy: Proceedings. Enercomp 95

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    World demand for composite materials is continuously increasing. High strength and rigidity, associated with light weight, are the key factors for composites' success. These materials find numerous applications in all sectors of industry. Presently, a sector of particular interest in terms of demand for composite materials is the energy industry. More and more applications are found in the field of the forms of energy: electrical, petroleum, gas, nuclear, solar and wind. The topics addressed in various sessions of the conference cover potential applications of the entire range of polymer, metal and ceramic composites in all sectors of energy. Papers are divided into sessions covering the following topics: properties; design and analysis; fracture; fatigue and long-term performance; new materials; innovative processing; liquid molding; joining and repairs; radiation curing; recycling; development in ceramic materials; innovations in metallic materials; metal-matrix composites; nondestructive evaluation; energy savings in transportation; pressure vessels and piping; wind energy applications; electrical components; concrete applications; power plant applications; and new materials in the energy field. Most of the papers have been processed separately for inclusion on the data base

  2. Braided reinforced composite rods for the internal reinforcement of concrete

    Science.gov (United States)

    Gonilho Pereira, C.; Fangueiro, R.; Jalali, S.; Araujo, M.; Marques, P.

    2008-05-01

    This paper reports on the development of braided reinforced composite rods as a substitute for the steel reinforcement in concrete. The research work aims at understanding the mechanical behaviour of core-reinforced braided fabrics and braided reinforced composite rods, namely concerning the influence of the braiding angle, the type of core reinforcement fibre, and preloading and postloading conditions. The core-reinforced braided fabrics were made from polyester fibres for producing braided structures, and E-glass, carbon, HT polyethylene, and sisal fibres were used for the core reinforcement. The braided reinforced composite rods were obtained by impregnating the core-reinforced braided fabric with a vinyl ester resin. The preloading of the core-reinforced braided fabrics and the postloading of the braided reinforced composite rods were performed in three and two stages, respectively. The results of tensile tests carried out on different samples of core-reinforced braided fabrics are presented and discussed. The tensile and bending properties of the braided reinforced composite rods have been evaluated, and the results obtained are presented, discussed, and compared with those of conventional materials, such as steel.

  3. Test of 1D carbon-carbon composite prototype tiles for the SPIDER diagnostic calorimeter

    Science.gov (United States)

    Serianni, G.; Pimazzoni, A.; Canton, A.; Palma, M. Dalla; Delogu, R.; Fasolo, D.; Franchin, L.; Pasqualotto, R.; Tollin, M.

    2017-08-01

    Additional heating will be provided to the thermonuclear fusion experiment ITER by injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction at Consorzio RFX in Padova (Italy), the production of negative ions will be studied and optimised. To this purpose the STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) diagnostic will be used to characterise the SPIDER beam during short operation (several seconds) and to verify if the beam meets the ITER requirement regarding the maximum allowed beam non-uniformity (below ±10%). The most important measurements performed by STRIKE are beam uniformity, beamlet divergence and stripping losses. The major components of STRIKE are 16 1D-CFC (Carbon matrix-Carbon Fibre reinforced Composite) tiles, observed at the rear side by a thermal camera. The requirements of the 1D CFC material include a large thermal conductivity along the tile thickness (at least 10 times larger than in the other directions); low specific heat and density; uniform parameters over the tile surface; capability to withstand localised heat loads resulting in steep temperature gradients. So 1D CFC is a very anisotropic and delicate material, not commercially available, and prototypes are being specifically realised. This contribution gives an overview of the tests performed on the CFC prototype tiles, aimed at verifying their thermal behaviour. The spatial uniformity of the parameters and the ratio between the thermal conductivities are assessed by means of a power laser at Consorzio RFX. Dedicated linear and non-linear simulations are carried out to interpret the experiments and to estimate the thermal conductivities; these simulations are described and a comparison of the experimental data with the simulation results is presented.

  4. Study of the barite mortar composition and its influence on determination of primary transmission curves applied to diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Firmino, Sandro F.; Souza, Wedla P. de; Hoff, Gabriela, E-mail: sandro.frmino@pucrs.b, E-mail: wedla.souza@acad.pucrs.b, E-mail: ghoff@pucrs.b [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Fac. de Fisica. Grupo de Experimentacao e Simulacao Computacional em Fisica Medica (GESiC); Vilhena, Marco T., E-mail: vilhena@pq.cnpq.b [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica

    2009-07-01

    The transmission of photons is an important parameter used to calculate the shielding material thickness. The method of computational simulation purposed, in this work, was applied to generate transmission curves for different energies for monoenergetic beams, on diagnostic radiology energy range, for values between 60 and 150 keV, in steps of 10 keV; and polienergetics spectra for accelerating tube tensions of 140 kVp and 150 kVp. The polienergetic spectra were selected from the Catalogue of Diagnostic X-Ray Spectra and Other Data [1] and changed using deterministic methods to add Aluminum filtration of 3.0 mm. The main objective of this work was to verify the sensitivity of photons spectra to differences observed on barite mortar composition. The computational universe generated simulates photon spectra irradiating directly a shielding wall. The different barite mortar compositions were defined base on a unique sample analysed using the energy dispersion spectroscopy (EDS) measurements in a Philips XL 30 Scanning Electron Microscope (SEM). The compositions were realized on four different areas of one sample: one on opened field of view and the three others uses focused field of view. It was possible verify differences on transmission curves for the different studied energies and different compositions of barite mortar. We suggest future works to study realistic spectra for different barite mortar compositions commercialized in Brazil. (author)

  5. International symposium on in vivo body composition studies: Program and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    This booklet contains the program and individual abstracts for papers presented at the International symposium on in vivo body composition studies. The presentations were divided into five sessions. Individual abstracts were indexed for the Energy Data Base. (DT)

  6. Diagnostics of Polymer Composite Materials and Analysis of Their Production Technology by Using the Method of Acoustic Emission

    Science.gov (United States)

    Bashkov, O. V.; Protsenko, A. E.; Bryanskii, A. A.; Romashko, R. V.

    2017-09-01

    The strength properties of glass-fiber-reinforced plastics produced by vacuum and vacuum autoclave molding techniques are studied. Based on acoustic emission data, a method of diagnostic and prediction of the bearing capacity of polymer composite materials by using data from three-point bending tests is developed. The method is based on evaluating changes in the exponent of a power function relating the total acoustic emission to the test stress.

  7. Young modulus and internal friction of a fiber-reinforced composite

    International Nuclear Information System (INIS)

    Ledbetter, H.M.; Lei, M.; Austin, M.W.

    1986-01-01

    By a kilohertz-frequency resonance method we determined the Young modulus and internal friction of a uniaxially fiber-reinforced composite. The composite comprised glass fibers in an epoxy-resin matrix. We studied three fiber contents: 0, 41, and 49 vol %. The Young modulus fit a linear rule of mixture. The internal friction fit a classical free-damped-oscillator model where one assumes a linear rule of mixture for three quantities: mass, force constant, and mechanical-resistance constant

  8. International society of sports nutrition position stand: diets and body composition

    OpenAIRE

    Aragon, Alan A.; Schoenfeld, Brad J.; Wildman, Robert; Kleiner, Susan; VanDusseldorp, Trisha; Taylor, Lem; Earnest, Conrad P.; Arciero, Paul J.; Wilborn, Colin; Kalman, Douglas S.; Stout, Jeffrey R.; Willoughby, Darryn S.; Campbell, Bill; Arent, Shawn M.; Bannock, Laurent

    2017-01-01

    Position Statement: The International Society of Sports Nutrition (ISSN) bases the following position stand on a critical analysis of the literature regarding the effects of diet types (macronutrient composition; eating styles) and their influence on body composition. The ISSN has concluded the following. 1) There is a multitude of diet types and eating styles, whereby numerous subtypes fall under each major dietary archetype. 2) All body composition assessment methods have strengths and limi...

  9. Influence of the choice of internal temperatures on the composition of CxHyOzNt plasmas out of thermodynamic equilibrium: Application to CH2 plasma

    International Nuclear Information System (INIS)

    Koalaga, Zacharie

    2002-01-01

    The purpose of this paper is to study the influence of the choice of internal temperatures on the composition of C x H y O z N t plasmas out of thermodynamic equilibrium. The numerical calculation is specially performed for CH 2 plasma in the pressure range 0.1-1 MPa and for the electron temperature range 5000-30 000 K. Precisely, the investigation of this plasma allows one to show that the choice of internal temperatures can have more influence on plasma composition than the choice of the form of the two-temperature Saha and Guldberg-Waage laws. Indeed, for one of the supposed hypotheses, it is observed that the two forms of the two-temperature system used here can give the same equilibrium composition by uncoupling the excitation temperature of the diatomic and the monatomic species. Great attention must then be given to the adopted hypothesis for internal temperature and not only to the form of the two temperature system used. An accurate comparison between the two models requires the measurement of plasma parameters such as the various internal temperatures and the species concentration. Therefore, we have also carried out an analysis of the potential experimental diagnostics of these plasma parameters. Such diagnostics can help to test and validate theoretical models

  10. Photoelastic Studies of Internal Stress Distributions of Unidirectional Composites.

    Science.gov (United States)

    1980-12-01

    34 verre a, If t nece, e.ry and Identify by block number) ..... ’Io-dimensional phutoelastli, models were used to determine internal taading-. and...Secretary of Defense for Research and Engineering, le Pe, ,tagon,, Uashington, D.C. 10301 ]2 Commandr, T)efens. lecn, ical Information Center, Cameron

  11. The Evolution and Internal Structure of Jupiter and Saturn with Compositional Gradients

    NARCIS (Netherlands)

    Vazan, A.; Helled, R.; Podolak, M.; Kovetz, A.

    2016-01-01

    The internal structure of gas giant planets may be more complex than the commonly assumed core-envelope structure with an adiabatic temperature profile. Different primordial internal structures as well as various physical processes can lead to non-homogenous compositional distributions. A

  12. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)

    Energy Technology Data Exchange (ETDEWEB)

    Pablant, N. A. [University of California-San Diego, La Jolla, California 92093 (United States); Burrell, K. H.; Groebner, R. J.; Kaplan, D. H. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Holcomb, C. T. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2010-10-15

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D{sub {alpha}} emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B{sub {theta}}/B{sub T} and |B| over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0x10{sup 19} m{sup -3}, and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  13. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited).

    Science.gov (United States)

    Pablant, N A; Burrell, K H; Groebner, R J; Holcomb, C T; Kaplan, D H

    2010-10-01

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D(α) emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B(θ)/B(T) and ∣B∣ over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0×10(19) m(-3), and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  14. Implementation of the International Code of Practice on Dosimetry in Diagnostic Radiology (TRS 457): Review of Test Results

    International Nuclear Information System (INIS)

    2011-01-01

    In 2007, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (IAEA Technical Reports Series No. 457). This publication recommends procedures for calibration and dosimetric measurement for the attainment of standardized dosimetry. It also addresses requirements both in standards dosimetry laboratories, especially Secondary Standards Dosimetry Laboratories (SSDLs), and in clinical centres for radiology, as found in most hospitals. The implementation of TRS No. 457 decreases the uncertainty in the dosimetry of diagnostic radiology beams and provides Member States with a unified and consistent framework for dosimetry in diagnostic radiology, which previously did not exist. A coordinated research project (CRP E2.10.06) was established in order to provide practical guidance to professionals at SSDLs and to clinical medical physicists on the implementation of TRS No. 457. This includes the calibration of radiological dosimetry instrumentation, the dissemination of calibration coefficients to clinical centres and the establishment of dosimetric measurement processes in clinical settings. The main goals of the CRP were to: Test the procedures recommended in TRS No. 457 for calibration of radiation detectors in different types of diagnostic beams and measuring instruments for varying diagnostic X ray modalities; Test the clinical dosimetry procedures, including the use of phantoms and patient dose surveys; Report on the practical implementation of TRS No. 457 at both SSDLs and hospital sites. Testing of TRS No. 457 was performed by a group of medical physicists from hospitals and SSDLs from various institutions worldwide

  15. Stability analysis of internally damped rotating composite shafts using a finite element formulation

    Science.gov (United States)

    Ben Arab, Safa; Rodrigues, José Dias; Bouaziz, Slim; Haddar, Mohamed

    2018-04-01

    This paper deals with the stability analysis of internally damped rotating composite shafts. An Euler-Bernoulli shaft finite element formulation based on Equivalent Single Layer Theory (ESLT), including the hysteretic internal damping of composite material and transverse shear effects, is introduced and then used to evaluate the influence of various parameters: stacking sequences, fiber orientations and bearing properties on natural frequencies, critical speeds, and instability thresholds. The obtained results are compared with those available in the literature using different theories. The agreement in the obtained results show that the developed Euler-Bernoulli finite element based on ESLT including hysteretic internal damping and shear transverse effects can be effectively used for the stability analysis of internally damped rotating composite shafts. Furthermore, the results revealed that rotor stability is sensitive to the laminate parameters and to the properties of the bearings.

  16. Monitoring on internal temperature of composite insulator with embedding fiber Bragg grating for early diagnosis

    Science.gov (United States)

    Chen, Wen; Tang, Ming

    2017-04-01

    The abnormal temperature rise is the precursor of the defective composite insulator in power transmission line. However no consolidated techniques or methodologies can on line monitor its internal temperature now. Thus a new method using embedding fiber Bragg grating (FBG) in fiber reinforced polymer (FRP) rod is adopted to monitor its internal temperature. To correctly demodulate the internal temperature of FRP rod from the Bragg wavelength shift of FBG, the conversion coefficient between them is deduced theoretically based on comprehensive investigation on the thermal stresses of the metal-composite joint, as well as its material and structural properties. Theoretical model shows that the conversion coefficients of FBG embedded in different positions will be different because of non-uniform thermal stress distribution, which is verified by an experiment. This work lays the theoretical foundation of monitoring the internal temperature of composite insulator with embedding FBG, which is of great importance to its health structural monitoring, especially early diagnosis.

  17. Literature Reviews on Modeling Internal Geometry of Textile Composites and Rate-Independent Continuum Damage

    Science.gov (United States)

    Su-Yuen, Hsu

    2011-01-01

    Textile composite materials have good potential for constructing composite structures where the effects of three-dimensional stresses are critical or geometric complexity is a manufacturing concern. There is a recent interest in advancing competence within Langley Research Center for modeling the degradation of mechanical properties of textile composites. In an initial effort, two critical areas are identified to pursue: (1) Construction of internal geometry of textile composites, and (2) Rate-independent continuum damage mechanics. This report documents reviews on the two subjects. Various reviewed approaches are categorized, their assumptions, methods, and progress are briefed, and then critiques are presented. Each review ends with recommended research.

  18. The effect of question format and task difficulty on reasoning strategies and diagnostic performance in Internal Medicine residents.

    Science.gov (United States)

    Heemskerk, Laura; Norman, Geoff; Chou, Sophia; Mintz, Marcy; Mandin, Henry; McLaughlin, Kevin

    2008-11-01

    Previous studies have suggested an association between reasoning strategies and diagnostic success, but the influence on this relationship of variables such as question format and task difficulty, has not been studied. Our objective was to study the association between question format, task difficulty, reasoning strategies and diagnostic success. Study participants were 13 Internal Medicine residents at the University of Calgary. Each was given eight problem-solving questions in four clinical presentations and were randomized to groups that differed only in the question format, such that a question presented as short answer (SA) to the first group was presented as extended matching (EM) to the second group. There were equal numbers of SA/EM questions and straightforward/difficult tasks. Participants performed think-aloud during diagnostic reasoning. Data were analyzed using multiple logistic regression. Question format was associated with reasoning strategies; hypothetico-deductive reasoning being used more frequently on EM questions and scheme-inductive reasoning on SA questions. For SA question, non-analytic reasoning alone was used more frequently to answer straightforward cases than difficult cases, whereas for EM questions no such association was observed. EM format and straightforward task increased the odds of diagnostic success, whereas hypothetico-deductive reasoning was associated with reduced odds of success. Question format and task difficulty both influence diagnostic reasoning strategies and studies that examine the effect of reasoning strategies on diagnostic success should control for these effects. Further studies are needed to investigate the effect of reasoning strategies on performance of different groups of learners.

  19. SYSTEM OF CONTROL FOR ACTIVE CAR SUSPENSION CHARACTERISTICS IN THE COMPOSITION OF THE EXPRESS DIAGNOSTICS LINE

    Directory of Open Access Journals (Sweden)

    Y. Borodenko

    2017-12-01

    Full Text Available The issues related to the organization and technical implementation of the control area for the output parameters of the active pendants as part of the technical control line are considered. An option is proposed to complete the baseline of express diagnostics with an additional bench for checking the angles of installation of the rear axle wheels. To reduce the cost of hardware implementation and increase the productivity of the measuring complex, it is proposed to compile software for computer diagnostic tools into a single testing.

  20. Interface and internal compatibility in a copper fibre cement composite

    Directory of Open Access Journals (Sweden)

    Kittl, P.

    1993-09-01

    Full Text Available This paper presents the mechanical behaviour of a compacted composite formed by short ductile copper fibres randomly distributed in portland cement matrix. The samples, a half with fibres and the other without them, were subjected to compression fatigue. So, 1 hertz and the value of stress corresponding to the 1% of the probability of fracture by gradual load were used. Diagrams of cumulative probability of fracture against cycles are obtained for both types of samples. Scanning electron microscopy shows that the mechanisms of fracture are different in each case. Samples of compacted neat-cement paste finish their life with a catastrophic fracture whereas samples of composite behave like a pseudoductile material devoid of catastrophic failure. The results are discussed and compared with the ones obtained by thermal shock and by the interface brittleness theory, as well as with the statistical theory of time-dependent fracture for cementitious materials subjected to cyclic loading. So, in the thermal shock microcracks are generated in the interface matrix-fibre which simultaneously act as emmitings and sumps of cracks whereas this does not occur in mechanical fatigue.

    Este trabajo presenta el comportamiento mecánico de un compuesto fabricado por compactación y constituido por fibras de cobre distribuidas aleatoriamente en una matriz de cemento portland. Las muestras, la mitad con fibras y la otra sin ellas, se sometieron a fatiga por compresión. El ciclo de carga fue de 1 hertz y la carga aplicada aquella correspondiente a la tensión asociada a un 1% de probabilidad de fractura cuando la carga se aplica gradualmente. Para ambos tipos de muestras se graficaron los diagramas de probabilidad acumulativa de fractura en función del número de ciclos. Con microscopía electrónica de barrido se observó que el mecanismo de fractura es diferente para cada tipo de muestras. Aquellas de pasta pura de cemento compactada terminaron su ciclo de

  1. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  2. Use, appropriateness, and diagnostic yield of screening colonoscopy: an international observational study (EPAGE)

    DEFF Research Database (Denmark)

    Burnand, B; JK, Harris; Wietlisbach, V

    2006-01-01

    was asked of all centers, it is possible that not all consecutive patients were included. Participating centers were a convenience sample and thus may not be representative. CONCLUSIONS: About 1 of 10 colonoscopies were performed for screening, preferentially in middle-aged individuals. A higher diagnostic...

  3. Agreement and Diagnostic Performance of FITNESSGRAM®, International Obesity Task Force, and Hungarian National BMI Standards

    Science.gov (United States)

    Laurson, Kelly R.; Welk, Gregory J.; Marton, Orsolya; Kaj, Mónika; Csányi, Tamás

    2015-01-01

    Purpose: This study examined agreement between all 3 standards (as well as relative diagnostic associations with metabolic syndrome) using a representative sample of youth from the Hungarian National Youth Fitness Study. Method: Body mass index (BMI) was assessed in a field sample of 2,352 adolescents (ages 10-18.5 years) and metabolic syndrome…

  4. Mathematics Diagnostic Testing in Engineering: An International Comparison between Ireland and Portugal

    Science.gov (United States)

    Carr, M.; Fidalgo, C.; Bigotte de Almeida, M. E.; Branco, J. R.; Santos, V.; Murphy, E.; Ní Fhloinn, E.

    2015-01-01

    Concern has been expressed throughout Europe about the significant deficiencies in the basic mathematical skills of many engineering undergraduates. Mathematics diagnostic tests in the UK, Ireland and Portugal have shown these shortcomings, which provide a challenge to those striving to introduce more innovative educational practices into…

  5. Diagnostic value of the 2011 International Federation for Cervical Pathology and Colposcopy Terminology in predicting cervical lesions

    Science.gov (United States)

    Zhang, Liqin; Yan, Ye; Han, Cha; Xue, Fengxia

    2018-01-01

    Objective To evaluate the diagnostic accuracy of the 2011 International Federation for Cervical Pathology and Colposcopy (IFCPC) colposcopic terminology. Methods The clinicopathological data of 2262 patients who underwent colposcopy from September 2012 to September 2016 were reviewed. The colposcopic findings, colposcopic impression, and cervical histopathology of the patients were analyzed. Correlations between variables were evaluated using cervical histopathology as the gold standard. Results Colposcopic diagnosis matched biopsy histopathology in 1482 patients (65.5%), and the weighted kappa strength of agreement was 0.480 (Pterminology can improve the diagnostic accuracy for all lesion severities. The categorization of major changes and minor changes is appropriate. However, colposcopic diagnosis remains unsatisfactory. Poor reproducibility of type 2 transformation zone and the significance of leukoplakia require further study. PMID:29507681

  6. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  7. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  8. Expanding the Operational Limits of the Single-Point Impedance Diagnostic for Internal Temperature Monitoring of Lithium-ion Batteries

    International Nuclear Information System (INIS)

    Spinner, Neil S.; Love, Corey T.; Rose-Pehrsson, Susan L.; Tuttle, Steven G.

    2015-01-01

    Highlights: • Single-point impedance diagnostic technique demonstrated for lithium-ion batteries • Correlation between imaginary impedance and internal temperature determined • Instantaneous monitoring of commercial lithium-ion battery internal temperature • Expanded temperature range from −10°C up to 95°C • Non-invasive method useful for practical temperature monitoring of commercial cells - Abstract: Instantaneous internal temperature monitoring of a commercial 18650 LiCoO 2 lithium-ion battery was performed using a single-point EIS measurement. A correlation between the imaginary impedance, –Z imag , and internal temperature at 300 Hz was developed that was independent of the battery’s state of charge. An Arrhenius-type dependence was applied, and the activation energy for SEI ionic conductivity was found to be 0.13 eV. Two separate temperature-time experiments were conducted with different sequences of temperature, and single-point impedance tests at 300 Hz were performed to validate the correlation. Limitations were observed with the upper temperature range (68°C < T < 95°C), and consequently a secondary, empirical fit was applied for this upper range to improve accuracy. Average differences between actual and fit temperatures decreased around 3-7°C for the upper range with the secondary correlation. The impedance response at this frequency corresponded to the anode/SEI layer, and the SEI is reported to be thermally stable up to around 100°C, at which point decomposition may occur leading to battery deactivation and/or total failure. It is therefore of great importance to be able to track internal battery temperatures up to this critical point of 100°C, and this work demonstrates an expansion of the single-point EIS diagnostic to these elevated temperatures

  9. Diagnosing holographic type dark energy models with the Statefinder hierarchy, composite null diagnostic and w- w' pair

    Science.gov (United States)

    Zhao, Ze; Wang, Shuang

    2018-03-01

    The main purpose of this work is to distinguish various holographic type dark energy (DE) models, including the ΛHDE, HDE, NADE, and RDE model, by using various diagnostic tools. The first diagnostic tool is the Statefinder hierarchy, in which the evolution of Statefinder hierarchy parmeter S (1) 3( z) and S (1) 4( z) are studied. The second is composite null diagnostic (CND), in which the trajectories of { S (1) 3, ɛ} and { S (1) 4, ɛ} are investigated, where ɛ is the fractional growth parameter. The last is w-w' analysis, where w is the equation of state for DE and the prime denotes derivative with respect to ln a. In the analysis we consider two cases: varying current fractional DE density Ω de0 and varying DE model parameter C. We find that: (1) both the Statefinder hierarchy and the CND have qualitative impact on ΛHDE, but only have quantitative impact on HDE. (2) S (1) 4 can lead to larger differences than S (1) 3, while the CND pair has a stronger ability to distinguish different models than the Statefinder hierarchy. (3) For the case of varying C, the { w,w'} pair has qualitative impact on ΛHDE; for the case of varying Ω de0, the { w, w'} pair only has quantitative impact; these results are different from the cases of HDE, RDE, and NADE, in which the {w,w'} pair only has quantitative impact on these models. In conclusion, compared with HDE, RDE, and NADE, the ΛHDE model can be easily distinguished by using these diagnostic tools.

  10. Exhaust Gas Temperature Measurements in Diagnostics of Turbocharged Marine Internal Combustion Engines Part II Dynamic Measurements

    Directory of Open Access Journals (Sweden)

    Korczewski Zbigniew

    2016-01-01

    Full Text Available The second part of the article describes the technology of marine engine diagnostics making use of dynamic measurements of the exhaust gas temperature. Little-known achievements of Prof. S. Rutkowski of the Naval College in Gdynia (now: Polish Naval Academy in this area are presented. A novel approach is proposed which consists in the use of the measured exhaust gas temperature dynamics for qualitative and quantitative assessment of the enthalpy flux of successive pressure pulses of the exhaust gas supplying the marine engine turbocompressor. General design assumptions are presented for the measuring and diagnostic system which makes use of a sheathed thermocouple installed in the engine exhaust gas manifold. The corrected thermal inertia of the thermocouple enables to reproduce a real time-history of exhaust gas temperature changes.

  11. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D.

    Science.gov (United States)

    Chen, J; Ding, W X; Brower, D L; Finkenthal, D; Muscatello, C; Taussig, D; Boivin, R

    2016-11-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  12. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

    International Nuclear Information System (INIS)

    Chen, J.; Ding, W. X.; Brower, D. L.; Finkenthal, D.; Muscatello, C.; Taussig, D.; Boivin, R.

    2016-01-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  13. Second International Diagnostic Accuracy Study for the Serological Detection of West Nile Virus Infection

    OpenAIRE

    Sanchini, Andrea; Donoso-Mantke, Oliver; Papa, Anna; Sambri, Vittorio; Teichmann, Anette; Niedrig, Matthias

    2013-01-01

    Background: In recent decades, sporadic cases and outbreaks in humans of West Nile virus (WNV) infection have increased. Serological diagnosis of WNV infection can be performed by enzyme-linked immunosorbent assay (ELISA), immunofluorescence assay (IFA) neutralization test (NT) and by hemagglutination-inhibition assay. The aim of this study is to collect updated information regarding the performance accuracy of WNV serological diagnostics. Methodology/Principal findings: In 2011, the E...

  14. Diagnostic accuracy of imaging modalities for internal derangements of temporomandibular joint

    International Nuclear Information System (INIS)

    Kobayashi, Kaoru; Igarashi, Chinami; Yuasa, Masao; Imanaka, Masahiro; Kondoh, Toshirou

    1998-01-01

    The purpose of this study was to evaluate and review the diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of imaging diagnosis for temporomandibular disorders. The role of diagnostic imaging is to detect and document specific anatomic abnormalities associated with the signs and symptoms in the temporomandibular joint. Magnetic resonance imaging (MR imaging) can accurately depict disc displacement and disc deformity. MR imaging is our first choice among the various imaging modalities for the patients with clinical signs and symptoms. However, it has been shown that intra-capsular adhesions and perforations of the disc and retrodiscal tissue are sometimes not detected by MR imaging. To improve the diagnostic technique for adhesions and perforations, double-contrast arthrotomography with fluoroscopy should be employed. The irregular surface of the eminences and the glenoid fossae shown by MR imaging and tomography are correlated with subchondral bone exposure by arthroscopy. Erosion of the condyles detected by MR imaging, tomography and rotational panoramic radiography is correlated with subchondral bone exposure detected by arthroscopy. (author). 69 refs

  15. Routine internal- and external-quality control data in clinical laboratories for estimating measurement and diagnostic uncertainty using GUM principles.

    Science.gov (United States)

    Magnusson, Bertil; Ossowicki, Haakan; Rienitz, Olaf; Theodorsson, Elvar

    2012-05-01

    Healthcare laboratories are increasingly joining into larger laboratory organizations encompassing several physical laboratories. This caters for important new opportunities for re-defining the concept of a 'laboratory' to encompass all laboratories and measurement methods measuring the same measurand for a population of patients. In order to make measurement results, comparable bias should be minimized or eliminated and measurement uncertainty properly evaluated for all methods used for a particular patient population. The measurement as well as diagnostic uncertainty can be evaluated from internal and external quality control results using GUM principles. In this paper the uncertainty evaluations are described in detail using only two main components, within-laboratory reproducibility and uncertainty of the bias component according to a Nordtest guideline. The evaluation is exemplified for the determination of creatinine in serum for a conglomerate of laboratories both expressed in absolute units (μmol/L) and relative (%). An expanded measurement uncertainty of 12 μmol/L associated with concentrations of creatinine below 120 μmol/L and of 10% associated with concentrations above 120 μmol/L was estimated. The diagnostic uncertainty encompasses both measurement uncertainty and biological variation, and can be estimated for a single value and for a difference. This diagnostic uncertainty for the difference for two samples from the same patient was determined to be 14 μmol/L associated with concentrations of creatinine below 100 μmol/L and 14 % associated with concentrations above 100 μmol/L.

  16. Consensus statement of the international summit on intellectual disability and Dementia related to post-diagnostic support.

    Science.gov (United States)

    Dodd, Karen; Watchman, Karen; Janicki, Matthew P; Coppus, Antonia; Gaertner, Claudia; Fortea, Juan; Santos, Flavia H; Keller, Seth M; Strydom, Andre

    2017-09-07

    Post diagnostic support (PDS) has varied definitions within mainstream dementia services and different health and social care organizations, encompassing a range of supports that are offered to adults once diagnosed with dementia until death. An international summit on intellectual disability and dementia held in Glasgow, Scotland in 2016 identified how PDS applies to adults with an intellectual disability and dementia. The Summit proposed a model that encompassed seven focal areas: post-diagnostic counseling; psychological and medical surveillance; periodic reviews and adjustments to the dementia care plan; early identification of behaviour and psychological symptoms; reviews of care practices and supports for advanced dementia and end of life; supports to carers/ support staff; and evaluation of quality of life. It also explored current practices in providing PDS in intellectual disability services. The Summit concluded that although there is limited research evidence for pharmacological or non-pharmacological interventions for people with intellectual disability and dementia, viable resources and guidelines describe practical approaches drawn from clinical practice. Post diagnostic support is essential, and the model components in place for the general population, and proposed here for use within the intellectual disability field, need to be individualized and adapted to the person's needs as dementia progresses. Recommendations for future research include examining the prevalence and nature of behavioral and psychological symptoms (BPSD) in adults with an intellectual disability who develop dementia, the effectiveness of different non-pharmacological interventions, the interaction between pharmacological and non-pharmacological interventions, and the utility of different models of support.

  17. Diagnostic value of DIAGNOdent in detecting caries under composite restorations of primary molars

    Directory of Open Access Journals (Sweden)

    Ava Vali Sichani

    2016-01-01

    Conclusion: DIAGNOdent showed a greater accuracy in detecting secondary caries under primary molar restorations, compared to radiographs. Although DIAGNOdent is an effective method for detecting caries under composite restorations, it is better to be used as an adjunctive method alongside other detecting procedures.

  18. Application of ceramic short fiber reinforced Al alloy matrix composite on piston for internal combustion engines

    Directory of Open Access Journals (Sweden)

    Wu Shenqing

    2010-11-01

    Full Text Available The preparation and properties of ceramic short fiber reinforced Al-Si alloy matrix composite and it’s application on the piston for internal combustion engines are presented. Alumina or aluminosilicate fibers reinforced Al-Si alloy matrix composite has more excellent synthetical properties at elevated temperature than the matrix alloys. A partially reinforced Al-Si alloy matrix composite piston produced by squeeze casting technique has a firm interface between reinforced and unreinforced areas, low reject rate and good technical tolerance. As a new kind of piston material, it has been used for mass production of about 400,000 pieces of automobile engines piston. China has become one of a few countries in which aluminum alloy matrix composite materials have been used in automobile industry and attained industrialization.

  19. Development of horn antenna mixer array with internal local oscillator module for microwave imaging diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Kuwahara, D., E-mail: dkuwahar@cc.tuat.ac.jp [Department of Mechanical Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); Ito, N. [Department of Intelligent System Engineering, Ube National College of Technology, Ube, Yamaguchi 755-8555 (Japan); Nagayama, Y. [Department of Helical Plasma Research, National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Yoshinaga, T. [Department of Applied Physics, National Defense Academy, Yokosuka, Kanagawa 239-0811 (Japan); Yamaguchi, S. [Department of Pure and Applied Physics, Kansai University, Suita, Osaka 564-8680 (Japan); Yoshikawa, M.; Kohagura, J. [Graduate School of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan); Sugito, S. [Equipment Development Center, Institute for Molecular Science, Okazaki, Aichi 444-8585 (Japan); Kogi, Y. [Department of Information Electronics, Fukuoka Institute of Technology, Fukuoka, Fukuoka 811-0295 (Japan); Mase, A. [Art, Science and Technology Center for Cooperative Research, Kyusyu University, Kasuga, Fukuoka 816-8580 (Japan)

    2014-11-15

    A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.

  20. Diagnostics of plasma produced by femtosecond laser pulse impact upon a target with an internal nanostructure

    International Nuclear Information System (INIS)

    Skobelev, I. Yu.; Faenov, A. Ya.; Gasilov, S. V.; Pikuz, T. A.; Pikuz, S. A.; Magunov, A. I.; Boldarev, A. S.; Gasilov, V. A.

    2010-01-01

    X-ray diagnostics of the interaction of femtosecond laser pulses with intensities of 10 16 -10 18 W/cm 2 with CO 2 clusters and frozen nanosize water particles is carried out. The stage of cluster expansion and the formation of a plasma channel, which governs the parameters of the formed X-ray radiation source and accelerated ion flows, is studied. The measurements are based on recording spatially resolved X-ray spectra of H- and He-like oxygen ions. Utilization of Rydberg transitions for spectra diagnostics makes it possible to determine plasma parameters on a time scale of t ∼ 10 ps after the beginning of a femtosecond pulse. The role of the rear edge of the laser pulse in sustaining the plasma temperature at a level of ∼100 eV in the stage of a nonadiabatic cluster expansion is shown. The analysis of the profiles and relative intensities of spectral lines allows one to determine the temperature and density of plasma electrons and distinguish the populations of 'thermal' ions and ions that are accelerated up to energies of a few tens of kiloelectronvolts. It is shown that the use of solid clusters made of frozen nanoscale water droplets as targets leads to a substantial increase in the number of fast He-like ions. In this case, however, the efficiency of acceleration of H-like ions does not increase, because the time of their ionization in plasma exceeds the time of cluster expansion.

  1. Development of an international code of practice for dosimetry in X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Pernicka, F.; Carlsson, G.A.; Dance, D.R.; DeWerd, L.A.; Kramer, H.-M.; Ng, K.-H.

    2001-01-01

    Medical x-ray examinations contribute greatly to the population dose from man-made radiation sources. There is a need to control this dose and therefore to optimise the design and use of x-ray imaging systems. A key stage in this process is the standardisation of the procedures for dose measurement in the clinic. The Dosimetry and Medical Radiation Physics Section of the IAEA has a number of activities to further advance the standards for x-ray diagnostics. One of these activities is the coordination of a working group to develop a code of practice, which will facilitate the IAEA calibration activities, TLD intercomparisons and audits, educational activities, and technical assistance to Member States. The code of practice will aid in the standardisation of various dosimetric techniques in x-ray diagnostic radiology. The CoP working group has had an initial meeting to review the current status of dosimetry for conventional radiology, fluoroscopy, mammography, computed tomography and dental radiology. The CoP will include the establishment of standards and calibrations at the SSDLs, phantom and patient measurements and procedures for dosimetry in the clinic. (author)

  2. The Internal, External, and Diagnostic Validity of Sluggish Cognitive Tempo: A Meta-Analysis and Critical Review

    Science.gov (United States)

    Becker, Stephen P.; Leopold, Daniel R.; Burns, G. Leonard; Jarrett, Matthew A.; Langberg, Joshua M.; Marshall, Stephen A.; McBurnett, Keith; Waschbusch, Daniel A.; Willcutt, Erik G.

    2015-01-01

    , although there is initial support for SCT being associated with processing speed, sustained attention, and metacognitive deficits. Conclusion This meta-analytic review provides strong support for the internal validity of SCT and preliminary support for the external validity of SCT. In terms of diagnostic validity, there is not currently enough evidence to describe SCT in diagnostic terms. Key directions for future research are discussed, including evaluating the conceptualization of SCT as a transdiagnostic construct and the need for longitudinal research. PMID:26903250

  3. Propagation of internal stresses in composite materials during heating and cooling according to thermal cycles of welding

    International Nuclear Information System (INIS)

    Gukasyan, L.E.; Belov, V.V.

    1977-01-01

    Investigations of free thermal expansion of a composite material, of fibre and matrix during welding thermal cycle make it possible to estimate mean internal strain and stress in the composite components, as well as the residual internal stress and strain present in the composite material after manufacturing. The samples investigated consisted of nickel-chromium EhI445 alloy, reinforced by tungsten-rhenium alloy fibres. As the composite material was cooled and heated in course of welding, the stress and strain changed their sign twice, the first time upon heating, the second time upon cooling. After complete cooling of the composite material residual stresses in the fibre stay at the proportionality level, while those in the matrix are lower. Experimental evidence of internal stress and strain appearing in the composite material during heating are fairly consistent with calculations in the elastic region, if account is taken of the temperature of internal residual stress relaxation upon heating

  4. Diagnostic validity Polish language version of the questionnaire MINI-KID (Mini International Neuropsychiatry Interview for Children and Adolescent).

    Science.gov (United States)

    Adamowska, Sylwia; Sylwia, Adamowska; Adamowski, Tomasz; Tomasz, Adamowski; Frydecka, Dorota; Dorota, Frydecka; Kiejna, Andrzej; Andrzej, Kiejna

    2014-10-01

    Since over forty years structuralized interviews for clinical and epidemiological research in child and adolescent psychiatry are being developed that should increase validity and reliability of diagnoses according to classification systems (DSM and ICD). The aim of the study is to assess the validity of the Polish version of MINI-KID (Mini International Neuropsychiatric Interview for Children and Adolescents) in comparison to clinical diagnosis made by a specialist in the field of child and adolescent psychiatry. There were 140 patients included in the study (93 boys, 66.4%, mean age 11.8±3.0 and 47 girls 33.5%, mean age 14.0±2.9). All the patients were diagnosed by the specialist in the field of child and adolescent psychiatry according to ICD-10 criteria and by the independent interviewer with the Polish version of MINI-KID (version 2.0, 2001). There was higher agreement between clinical diagnoses and diagnoses based on MINI-KID interview with respect to eating disorders and externalizing disorders (κ 0.43-0.56) and lower in internalizing disorders (κ 0.13-0.45). In the clinical interview, there was smaller number of diagnostic categories (maximum 3 diagnoses per one patient) in comparison to MINI-KID (maximum 10 diagnoses per one patient), and the smaller percentage of patients with one diagnosis (65,7%) in comparison to MINI-KID interview (72%). Our study has shown satisfactory validity parameters of MINI-KID questionnaire, promoting its use for clinical and epidemiological settings. The Mini International Neuropsychiatry Interview for Children and Adolescent (MINI-KID) is the first structuralized diagnostic interview for assessing mental status in children and adolescents, which has been translated into Polish language. Our validation study demonstrated satisfactory psychometric properties of the questionnaire, enabling its use in clinical practice and in research projects. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Internal plasma diagnostic with a multichannel magnetic probe system using automatic data acquisition

    International Nuclear Information System (INIS)

    Korten, M.; Carolan, P.G.; Sand, F.; Waelbroeck, F.

    1975-04-01

    A 20-channel magnetic probe system inserted into the plasma is used to measure spatial distributions of poloidal and toroidal magnetic fields in the pulsed toroidal high β-experiment TEE. Plasma parameters, e.g. the β-value, toroidal current density and radial pressure distribution were derived applying static equilibrium theory and can be calculated from the measurements. A data acquisition system used in conjuction with a process computer was operated to obtain the experimental data automatically and to perform the multiple computational tasks. The program system described was built to serve as a first stage of a more common software system applicable for computational data handling for different diagnostics of a plasma physics confinement experiment. (orig.) [de

  6. Internal quality control of PCR-based genotyping methods in research studies and patient diagnostics

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Genetic analyses are increasingly integrated in the clinical laboratory, and internal quality control programmes are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) by ammonium acetate....... Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences we propose an internal quality control programme for widely used PCR-based haemostasis polymorphism analyses.......-isolation (pre-analytical factors), DNA-amplification, digestion with restriction enzymes, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 microg/ml blood...

  7. Updating the International Standards for Tuberculosis Care. Entering the era of molecular diagnostics.

    Science.gov (United States)

    Hopewell, Philip C; Fair, Elizabeth L; Uplekar, Mukund

    2014-03-01

    The International Standards for Tuberculosis Care, first published in 2006 (Lancet Infect Dis 2006;6:710-725.) with a second edition in 2009 ( www.currytbcenter.ucsf.edu/international/istc_report ), was produced by an international coalition of organizations funded by the United States Agency for International Development. Development of the document was led jointly by the World Health Organization and the American Thoracic Society, with the aim of promoting engagement of all care providers, especially those in the private sector in low- and middle-income countries, in delivering high-quality services for tuberculosis. In keeping with World Health Organization recommendations regarding rapid molecular testing, as well as other pertinent new recommendations, the third edition of the Standards has been developed. After decades of dormancy, the technology available for tuberculosis care and control is now rapidly evolving. In particular, rapid molecular testing, using devices with excellent performance characteristics for detecting Mycobacterium tuberculosis and rifampin resistance, and that are practical and affordable for use in decentralized facilities in low-resource settings, is being widely deployed globally. Used appropriately, both within tuberculosis control programs and in private laboratories, these devices have the potential to revolutionize tuberculosis care and control, providing a confirmed diagnosis and a determination of rifampin resistance within a few hours, enabling appropriate treatment to be initiated promptly. Major changes have been made in the standards for diagnosis. Additional important changes include: emphasis on the recognition of groups at increased risk of tuberculosis; updating the standard on antiretroviral treatment in persons with tuberculosis and human immunodeficiency virus infection; and revising the standard on treating multiple drug-resistant tuberculosis.

  8. Control of internal and external short circuits in lithium batteries using a composite thermal switch

    Science.gov (United States)

    Mcdonald, Robert C.; Pickett, Jerome; Goebel, Franz

    1991-01-01

    A composite material has been developed, consisting of a blend of metal and fluorocarbon particles, which behaves as an electronic conductor at room temperature and which abruptly becomes an insulator at a predetermined temperature. This switching behavior results from the difference in thermal expansion coefficients between the conductive and non-conductive portions of the composite. This material was applied as a thin film between the carbon cathode in Li/SOCl2 cells, and the metallic cathode current collector. Using test articles incorporating this feature it was shown that lithium cells externally heated or internally heated during a short circuit lost rate capability and the ability to overheat well below the melting point of lithium (180 C). Thus, during an internal or external cell short circuit, the potential for thermal runaway involving reactions of molten lithium is avoided.

  9. Cross-cultural and comparative epidemiology of insomnia: the Diagnostic and statistical manual (DSM), International classification of diseases (ICD) and International classification of sleep disorders (ICSD).

    Science.gov (United States)

    Chung, Ka-Fai; Yeung, Wing-Fai; Ho, Fiona Yan-Yee; Yung, Kam-Ping; Yu, Yee-Man; Kwok, Chi-Wa

    2015-04-01

    To compare the prevalence of insomnia according to symptoms, quantitative criteria, and Diagnostic and Statistical Manual of Mental Disorders, 4th and 5th Edition (DSM-IV and DSM-5), International Classification of Diseases, 10th Revision (ICD-10), and International Classification of Sleep Disorders, 2nd Edition (ICSD-2), and to compare the prevalence of insomnia disorder between Hong Kong and the United States by adopting a similar methodology used by the America Insomnia Survey (AIS). Population-based epidemiological survey respondents (n = 2011) completed the Brief Insomnia Questionnaire (BIQ), a validated scale generating DSM-IV, DSM-5, ICD-10, and ICSD-2 insomnia disorder. The weighted prevalence of difficulty falling asleep, difficulty staying asleep, waking up too early, and non-restorative sleep that occurred ≥3 days per week was 14.0%, 28.3%, 32.1%, and 39.9%, respectively. When quantitative criteria were included, the prevalence dropped the most from 39.9% to 8.4% for non-restorative sleep, and the least from 14.0% to 12.9% for difficulty falling asleep. The weighted prevalence of DSM-IV, ICD-10, ICSD-2, and any of the three insomnia disorders was 22.1%, 4.7%, 15.1%, and 22.1%, respectively; for DSM-5 insomnia disorder, it was 10.8%. Compared with 22.1%, 3.9%, and 14.7% for DSM-IV, ICD-10, and ICSD-2 in the AIS, cross-cultural difference in the prevalence of insomnia disorder is less than what is expected. The prevalence is reduced by half from DSM-IV to DSM-5. ICD-10 insomnia disorder has the lowest prevalence, perhaps because excessive concern and preoccupation, one of its diagnostic criteria, is not always present in people with insomnia. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Towards better description of solar activity variation in the International Reference Ionosphere topside ion composition model

    Czech Academy of Sciences Publication Activity Database

    Truhlík, Vladimír; Bilitza, D.; Třísková, Ludmila

    2015-01-01

    Roč. 55, č. 8 (2015), s. 2099-2105 ISSN 0273-1177 R&D Projects: GA MŠk(CZ) LH11123 Institutional support: RVO:68378289 Keywords : ion composition * topside ionosphere * solar activity * empirical model * International Reference Ionosphere Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.409, year: 2015 http://www.sciencedirect.com/science/article/pii/S027311771400489X

  11. Marginal and internal fit of nano-composite CAD/CAM restorations

    Directory of Open Access Journals (Sweden)

    So-Hyun Park

    2016-02-01

    Full Text Available Objectives The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods A full veneer crown and an mesio-occluso-distal (MOD inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU and experimental nano-composite CAD/CAM blocks (EB under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000. In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001. Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000. Conclusions The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

  12. Analysis of neutron diffraction peak broadening caused by internal stresses in composite materials

    International Nuclear Information System (INIS)

    Todd, R.I.; Borsa, C.; Derby, B.

    1994-01-01

    Neutron diffraction is an essential tool in the study of internal stresses in composite materials. In most work only the peak shifts caused by the related elastic strains are considered, but other valuable information exists in the form of peak shape changes. The conditions under which the pure diffraction profile of the composite (i.e. the profile when all sources of broadening not caused by the residual stresses are removed) represents the probability distribution of the peak shifts corresponding to the strains are examined. It is shown that in these conditions, the pure diffraction profile has no attributes of particle size broadening (and vice versa), thereby providing a test for the validity of results interpreted in this way. The experimental derivation of measured strain distributions in Al 2 O 3 /SiCp composites using neutron diffraction is described. No apparent particle size broadening was detected, demonstrating the validity of the results, which also satisfied other tests for consistency

  13. Fibre Reinforced Polymer Composites as Internal and External Reinforcements for Building Elements

    Directory of Open Access Journals (Sweden)

    Cătălin Banu

    2008-01-01

    Full Text Available During the latest decades fibre reinforced polymer (FRP composite materials have proven valuable properties and suitable to be used in construction of new buildings and in upgrading the existing ones. These materials have covered the road from research laboratory and demonstration projects to implementation in actual structures. Nowadays the civil and structural engineering communities are about to commence the stage in which the use of FRP composites is becoming a routine similar to that of traditional material such as concrete, masonry and wood. Two main issues are presented in this paper, the use of FRP composite materials for new structural members (internal reinforcements and strengthening of existing members (externally bonded reinforcements. The advantages and disadvantages as well as the problems and constraints associated with both issues are discussed in detail mainly related to concrete members.

  14. Diagnostic value of DIAGNOdent in detecting caries under composite restorations of primary molars.

    Science.gov (United States)

    Sichani, Ava Vali; Javadinejad, Shahrzad; Ghafari, Roshanak

    2016-01-01

    Direct observation cannot detect caries under restorations; therefore, the aim of this study was to compare the accuracy of radiographs and DIAGNOdent in detecting caries under restorations in primary teeth using histologic evaluation. A total of 74 previously extracted primary molars (37 with occlusal caries and 37 without caries) were used. Class 1 cavity preparations were made on each tooth by a single clinician and then the preparations were filled with composite resin. The accuracy of radiographs and DIAGNOdent in detecting caries was compared using histologic evaluation. The data were analyzed by SPSS version 21 using Chi-square, Mc Namara statistical tests and receiver operating characteristic curve. The significance was set at 0.05. The sensitivity and specificity for DIAGNOdent were 70.97 and 83.72, respectively. Few false negative results were observed, and the positive predictive value was high (+PV = 75.9) and the area under curve was more than 0.70 therefore making DIAGNOdenta great method for detecting caries (P = 0.0001). Two observers evaluated the radiographs and both observers had low sensitivity ( first observer: 48.39) (second observer: 51.61) and high specificity (both observers: 79.07). The +PV was lower than DIAGNOdent and the area under curve for both observers was less than 0.70. However, the difference between the two methods was not significant. DIAGNOdent showed a greater accuracy in detecting secondary caries under primary molar restorations, compared to radiographs. Although DIAGNOdent is an effective method for detecting caries under composite restorations, it is better to be used as an adjunctive method alongside other detecting procedures.

  15. IR thermography methods for evaluation of internal defects in light composite armours

    International Nuclear Information System (INIS)

    Swiderski, W.; Szabra, D.; Szudrowicz, M.

    2009-01-01

    Complete text of publication follows. Light composite armour is a preferred solution against military and paramilitary sources of present threats as the reducing mass of battle vehicles provides a possibility of their quick air-transport. The light armours of these vehicles should be resistant against: common and rifle bullets, grenades, anti-personal mines, IED - improvised explosive devices. The range of military applications anticipated for composite armours covers a broad spectrum of materials and designs. Materials of composite armours include graphite epoxy, glass epoxy and aramid fiber composites. The composites that have been examined can include a variety of defects, such as ballistic impacts, embedded defects, manufacturing defects, thermal damage, moisture ingress and other induced defects. Methods for testing ballistic protection of light armours are known and used. First of all they consist of checking armours resistance against the bullets where the bullet velocity is known. Moreover the V50 velocity is defined during the test. In this method the V 50 velocity of a round or standard fragment is defined (according to STANAG 2920) as the velocity at which armour is penetrated at the probability 50%. The distribution of points hit by bullets or fragments on the surface of an armour is also important. In fact, only correct distribution of these points provides a guaranty for an impartial assessment of tested designs. After hitting by a bullet, shape and size of an area of damage in composite armours depends on the type and design of armour, and type of reinforcing material is particularly important. Knowledge of damage characteristics allows to arrange hitting points to avoid overlapping of damaged areas. Nondestructive testing by using IR thermography methods is very useful in evaluation of internal defects. In the paper we present the dependence between the energy of fragments/or bullets and the dimension of internal defects. (author)

  16. Hyperfine Induced Transitions as Diagnostics of Isotopic Composition and Densities of Low-Density Plasmas

    Science.gov (United States)

    Brage, Tomas; Judge, Philip G.; Aboussaïd, Abdellatif; Godefroid, Michel R.; Jönsson, Per; Ynnerman, Anders; Froese Fischer, Charlotte; Leckrone, David S.

    1998-06-01

    The J = 0 --> J' = 0 radiative transitions, usually viewed as allowed through two-photon decay, may also be induced by the hyperfine (HPF) interaction in atoms or ions having a nonzero nuclear spin. We compute new and review existing decay rates for the nsnp 3PoJ --> ns2 1SJ'=0 transitions in ions of the Be (n = 2) and Mg (n = 3) isoelectronic sequences. The HPF induced decay rates for the J = 0 --> J' = 0 transitions are many orders of magnitude larger than those for the competing two-photon processes, and when present are typically 1 or 2 orders of magnitude smaller than the decay rates of the magnetic quadrupole (J = 2 --> J' = 0) transitions for these ions. Several HPF induced transitions are potentially of astrophysical interest in ions of C, N, Na, Mg, Al, Si, K, Cr, Fe, and Ni. We highlight those cases that may be of particular diagnostic value for determining isotopic abundance ratios and/or electron densities from UV or EUV emission-line data. We present our atomic data in the form of scaling laws so that, given the isotopic nuclear spin and magnetic moment, a simple expression yields estimates for HPF induced decay rates. We examine some UV and EUV solar and nebular data in light of these new results and suggest possible applications for future study. We could not find evidence for the existence of HPF induced lines in the spectra we examined, but we demonstrate that existing data have come close to providing interesting upper limits. For the planetary nebula SMC N2, we derive an upper limit of 0.1 for 13C/12C from Goddard High-Resolution Spectrograph data obtained by Clegg. It is likely that more stringent limits could be obtained using newer data with higher sensitivities in a variety of objects.

  17. Systematic Internal Transcribed Spacer Sequence Analysis for Identification of Clinical Mold Isolates in Diagnostic Mycology: a 5-Year Study▿ †

    Science.gov (United States)

    Ciardo, Diana E.; Lucke, Katja; Imhof, Alex; Bloemberg, Guido V.; Böttger, Erik C.

    2010-01-01

    The implementation of internal transcribed spacer (ITS) sequencing for routine identification of molds in the diagnostic mycology laboratory was analyzed in a 5-year study. All mold isolates (n = 6,900) recovered in our laboratory from 2005 to 2009 were included in this study. According to a defined work flow, which in addition to troublesome phenotypic identification takes clinical relevance into account, 233 isolates were subjected to ITS sequence analysis. Sequencing resulted in successful identification for 78.6% of the analyzed isolates (57.1% at species level, 21.5% at genus level). In comparison, extended in-depth phenotypic characterization of the isolates subjected to sequencing achieved taxonomic assignment for 47.6% of these, with a mere 13.3% at species level. Optimization of DNA extraction further improved the efficacy of molecular identification. This study is the first of its kind to testify to the systematic implementation of sequence-based identification procedures in the routine workup of mold isolates in the diagnostic mycology laboratory. PMID:20573873

  18. Systematic internal transcribed spacer sequence analysis for identification of clinical mold isolates in diagnostic mycology: a 5-year study.

    Science.gov (United States)

    Ciardo, Diana E; Lucke, Katja; Imhof, Alex; Bloemberg, Guido V; Böttger, Erik C

    2010-08-01

    The implementation of internal transcribed spacer (ITS) sequencing for routine identification of molds in the diagnostic mycology laboratory was analyzed in a 5-year study. All mold isolates (n = 6,900) recovered in our laboratory from 2005 to 2009 were included in this study. According to a defined work flow, which in addition to troublesome phenotypic identification takes clinical relevance into account, 233 isolates were subjected to ITS sequence analysis. Sequencing resulted in successful identification for 78.6% of the analyzed isolates (57.1% at species level, 21.5% at genus level). In comparison, extended in-depth phenotypic characterization of the isolates subjected to sequencing achieved taxonomic assignment for 47.6% of these, with a mere 13.3% at species level. Optimization of DNA extraction further improved the efficacy of molecular identification. This study is the first of its kind to testify to the systematic implementation of sequence-based identification procedures in the routine workup of mold isolates in the diagnostic mycology laboratory.

  19. Internal carotid artery occlusion or subocclusion: Contemporary diagnostic challenges: Case report

    Directory of Open Access Journals (Sweden)

    Popov Petar

    2009-01-01

    Full Text Available Introduction. Measurement of vessel stenosis using ultrasonography or magnetic resonance is still the principal method for determining the severity of carotid atherosclerosis and need for endarterectomy. Case Outline. A 56-year-old male was admitted to the Cardiovascular Institute 'Dedinje' due to a clinically asymptomatic restenosis of the operated left internal carotid artery (ICA. Angiography and magnetic resonance angiography (MRA in previous hospitalization had revealed occluded right ICA. However, routine duplex ultrasonography revealed a highgrade restenosis (85% of the left ICA and subocclusion of the right ICA by an ulcerated plaque (confirmed on repeated MRA. Conclusion. Selective arteriography examination could misrepresent the degree of stenosis especially in patents with the ICA that seems to be occluded. MRA is considered the method of choice for identifying pseudo-occlusions of ICA.

  20. Internal quality assurance in diagnostic microbiology: A simple approach for insightful data.

    Directory of Open Access Journals (Sweden)

    Valentin Scherz

    Full Text Available Given the importance of microbiology results on patient care, high quality standards are expected. Internal quality assurance (IQA could mitigate the limitations of internal quality control, competency assessment and external quality assurance, adding a longitudinal insight, including pre- and post-analytical steps. Here, we implemented an IQA program in our clinical microbiology facilities with blind resubmission of routine samples during 22 months. One-hundred-and-twenty-one out of 123 (98.4% serological analyses and 112 out of 122 (91.8% molecular analyses were concordant. Among the discordances in molecular biology analyses, 6 results were low positive samples that turned out negative, likely due to stochastic repartition of nucleic acids. Moreover, one identified retranscription error led us to implement automated results transmission from the Applied Biosystems instruments to the laboratory information system (LIS. Regarding Gram stain microscopy, 560 out of 745 (75.2% of compared parameters were concordant. As many as 67 out of 84 (79.8% pairs of culture results were similar, including 16 sterile pairs, 27 having identical identification or description and semi-quantification and 24 only showing variations in semi-quantification with identical description or identification of colonies. Seventeen pairs had diverging identification or description of colonies. Culture was twice only done for one member of the pairs. Regarding antibiotic susceptibility testing, a major discrepancy was observed in 5 out of 48 results (10.4%. In conclusion, serological tests were highly reproducible. Molecular diagnosis also revealed to be robust except when the amounts of nucleic acids present in the sample were close to the limits of detection. Conventional microbiology was less robust with major discrepancies reaching 39.5% of the samples for microscopy. Similarly, culture and antibiotic susceptibility testing were prone to discrepancies. This work was

  1. Effects of host cell sterol composition upon internalization of Yersinia pseudotuberculosis and clustered β1 integrin.

    Science.gov (United States)

    Kim, JiHyun; Fukuto, Hana S; Brown, Deborah A; Bliska, James B; London, Erwin

    2018-01-26

    Yersinia pseudotuberculosis is a foodborne pathogenic bacterium that causes acute gastrointestinal illness, but its mechanisms of infection are incompletely described. We examined how host cell sterol composition affected Y. pseudotuberculosis uptake. To do this, we depleted or substituted cholesterol in human MDA-MB-231 epithelial cells with various alternative sterols. Decreasing host cell cholesterol significantly reduced pathogen internalization. When host cell cholesterol was substituted with various sterols, only desmosterol and 7-dehydrocholesterol supported internalization. This specificity was not due to sterol dependence of bacterial attachment to host cells, which was similar with all sterols studied. Because a key step in Y. pseudotuberculosis internalization is interaction of the bacterial adhesins invasin and YadA with host cell β1 integrin, we compared the sterol dependence of wildtype Y. pseudotuberculosis internalization with that of Δ inv , Δ yadA , and Δ inv Δ yadA mutant strains. YadA deletion decreased bacterial adherence to host cells, whereas invasin deletion had no effect. Nevertheless, host cell sterol substitution had a similar effect on internalization of these bacterial deletion strains as on the wildtype bacteria. The Δ inv Δ yadA double mutant adhered least to cells and so was not significantly internalized. The sterol structure dependence of Y. pseudotuberculosis internalization differed from that of endocytosis, as monitored using antibody-clustered β1 integrin and previous studies on other proteins, which had a more permissive sterol dependence. This study suggests that agents could be designed to interfere with internalization of Yersinia without disturbing endocytosis. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.

  2. Main areas for the sociological support of organizational risks diagnostics and prevention in the internal affairs bodies

    Directory of Open Access Journals (Sweden)

    T H Dzhanteev

    2016-12-01

    Full Text Available The article considers the use of theoretical and applied sociological studies to identify and prevent negative consequences of the organizational risks in the internal affairs bodies, such as: insufficient quality of the organizational structure; failures in the design of organizational structures; poor coordination and regulation; inconsistency of resources provision; mistakes in the selection and placement of personnel; shortcomings in the organization of interaction with the public; incorrect definition of the needs of citizens in the field of law enforcement; poor quality of law enforcement services; inadequate training of personnel for the interaction with citizens. The author describes the role of the sociological support in the diagnostics of organizational risks, and pays particular attention to the factors contributing to the occurrence of undesirable situations and to the cause-and-effect relationships between various events associated with the risks. The article emphasizes the exceptional importance of forecasting negative consequences of risk situations and developing measures to minimize negative effects of organizational risks in law enforcement in general and in the internal affairs bodies in particular.

  3. X-linked hypohidrotic ectodermal dysplasia (XLHED): clinical and diagnostic insights from an international patient registry.

    Science.gov (United States)

    Fete, Mary; Hermann, Julie; Behrens, Jeffrey; Huttner, Kenneth M

    2014-10-01

    The web-based Ectodermal Dysplasia International Registry (EDIR) is a comprehensive patient-reported survey contributing to an understanding of ectodermal dysplasia (ED). XLHED is the most common of the genetic ED syndromes and was the primary diagnosis reported by 223/835 respondents (141 males and 82 females). Overall, 96% of XLHED registrants reported as least one other affected family member and 21% reported a family history of infant or childhood deaths, consistent with the published mortality data in this disorder. In general, XLHED is diagnosed by the triad of decreased sweating, reduced hair, and hypodontia (present in 89%, 74%, and 74% of XLHED respondents). Additionally, the registry dataset confirmed a spectrum of life-long XLHED clinical complications including recurrent sinus infections (49% males, 52% females), nasal congestion often foul smelling and interfering with feeding (73% males, 27% females), eczema (66% males, 40% females), wheezing (66% males, 45% females), and a hoarse, raspy voice (67% males, 23% females). The Registry results also highlighted features consistently differentiating XLHED from the non-hypohidrotic ED syndromes including the frequency of infant/childhood deaths, the presence of limb/digit abnormalities, feeding issues related to nasal discharge, dentures, and a diagnosis of asthma. These results represent the largest collection of data on a broad-spectrum of health-related issues affecting ED patients. This project provides information for expanding knowledge of the natural history of XLHED, and as such may facilitate the diagnosis and treatment of its varied and lifelong medical challenges. © 2014 Wiley Periodicals, Inc.

  4. Development of the regulation mapping of 1 MW internal combustion engine for diagnostic scopes

    International Nuclear Information System (INIS)

    Barelli, L.; Bidini, G.; Bonucci, F.

    2009-01-01

    The present work deals with the creation, on the basis of experimental data, of the regulation maps for the 1 MW cogenerative internal combustion engine (ICE) installed at the Engineering Faculty of Perugia University. The regulation logic mapping is necessary for the development of a thermodynamic model of the engine behaviour to simulate the effects of possible malfunctions occurrence, such as deterioration or fouling not directly experienced on the engine. Such a work is carried out as a part of a more general research activity concerning the development of a diagnosis system for the cogenerative plant. Therefore, a first phase of the present work relates to the experimental data gathering campaign and the consequent data analysis to individuate the characteristic parameters of regulation. In the second phase, instead, a neural simulator of the control logic was developed on the basis of the experimental data for the engine operation at full load (initially considered at 980 kW) and during transitory. Consequently, through such a simulator the regulation maps of the engine were determined considering the variation range of all the characteristic parameters. Finally, a more accurate analysis of the experimental data relative to the dependence of the produced electric power at regimen on the fuel valve position, encouraged the authors to develop a further neural simulator able to reproduce the regulation commands for different values of the target power set for the regimen operation. Consequently, also the regulation mapping was revised obtaining a synthetic representation of the regulation logic useful for the implementation in the thermodynamic model of the engine dynamic behaviour

  5. Diagnostic studies on the internal derangement of temporomandibular joint in MR imaging (MRI)

    International Nuclear Information System (INIS)

    Tange, Kazuhisa

    1991-01-01

    The T1 and T2 relaxation times of the phantom were measured in the magnetic resonance imaging (MRI) using the headcoil and the surface coil for the temporomandibular joint (TMJ). The purpose of this study on the phantom was to investigate the feature of the surface coil for TMJ (TMJ-coil). Two spin echo (TR=2,000 msec, TE=30 msec and TR=2,000 msec, TE=80 msec) and one inversion recovery (TR=2,000 msec, TI=500 msec) pulse sequence with a 256 x 256 matrix and two excitations were used, and the T1 and T2 values were obtained by the ROI (region of interest) in the maps of T1 and T2. As a result of the phantom study, I acquired the knowledge that I have to set an object on the center of the TMJ-coil with a distance more than 3 cm. With the TMJ-coil, measurements of T1 and T2 relaxation times of meniscus and lateral pterygoid muscle were performed on 30 normal volunteers and 30 patients who had been diagnosed internal derangement of the TMJ. The 30 patients were classified into two groups; one composed of 15 patients diagnosed as meniscal displacement with reduction (group MDWR) and the other was of 15 patients diagnosed as meniscal displacement without reduction (group MDWOR). Between the volunteers and patients, there was a significant decrease in T1 and T2 relaxation times of meniscus and T1 relaxation times of lateral pterygoid muscle. There was no significant difference between group MDWR and group MDWOR. There was no significant difference in sex or age, either. The more long-term the patients were, the more the T1 relaxation times decreased. The decrease in T1 and T2 relaxation times of meniscus probably represented water loss. The decrease in T1 and T2 relaxation times of lateral pterygoid muscle was slight compared with that of meniscus. (author)

  6. Background and perspective on rapid progress and deepening of international development of nuclear industry-composition of international nuclear energy business 'cooperation and competition'

    International Nuclear Information System (INIS)

    Kano, Tokio; Kanda, Keji; Ishizuka, Nobuo

    2005-01-01

    Based on the recognition that international development of nuclear industry was important by a viewpoint of international cooperation to neighboring Asian area and also it was the trump that defeated a feeling of domestic confinement, the Japan Atomic Industrial Forum (JAIF) founded Nuclear energy international development gathering' in November 2004. On that occasion our magazine (March, 2005 issue) featured 'prospects and problem of the international development of nuclear energy use'. Slightly for half a year afterwards this nuclear energy international development has been rapidly deepened and become a close-up as a policy of an important strategy of the field of nuclear energy that the government and the private sector were united to make. Therefore the nuclear energy international development was secondly featured from multidirectional points of view such as a background of nuclear energy international development, composition of international nuclear energy business, a main strategy of three makers, approach of finance / a business firm. (T. Tanaka)

  7. Smoke composition and predicting relationships for international commercial cigarettes smoked with three machine-smoking conditions.

    Science.gov (United States)

    Counts, M E; Morton, M J; Laffoon, S W; Cox, R H; Lipowicz, P J

    2005-04-01

    The study objectives were to determine the effects of smoking machine puffing parameters on mainstream smoke composition and to express those effects as predicting relationships. Forty-eight commercial Philip Morris USA and Philip Morris International cigarettes from international markets and the 1R4F reference cigarette were machine-smoked using smoking conditions defined by the International Organization of Standardization (ISO), the Massachusetts Department of Public Health (MDPH), and Health Canada (HC). Cigarette tobacco fillers were analyzed for nitrate, nicotine, tobacco-specific nitrosamines (TSNA), and ammonia. Mainstream yields for tar and 44 individual smoke constituents and "smoke pH" were determined. Cigarette constituent yields typically increased in the order ISOrelationships were developed between ISO tar and ISO, MDPH, and HC constituent yields and between MDPH tar and HC tar and respective smoking condition yields. MDPH and HC constituent yields could be predicted with similar reliability using ISO tar or the corresponding smoking-condition tar. The reliability of the relationships varied from strong to weak, depending on particular constituents. Weak predicting relationships for nitrogen oxides and TSNA's, for example, were improved with inclusion of tobacco filler composition factors. "Smoke pH" was similar for all cigarettes at any one smoking condition, and overall marginally lower at HC conditions than at ISO or MDPH conditions.

  8. Carbon Fiber Reinforced Carbon Composite Valve for an Internal Combustion Engine

    Science.gov (United States)

    Rivers, H. Kevin (Inventor); Ransone, Philip O. (Inventor); Northam, G. Burton (Inventor)

    1999-01-01

    A carbon fiber reinforced carbon composite valve for internal combustion engines and the like formed of continuous carbon fibers throughout the valve's stem and head is disclosed. The valve includes braided carbon fiber material over axially aligned unidirectional carbon fibers forming a valve stem; the braided and unidirectional carbon fibers being broomed out at one end of the valve stem forming the shape of the valve head; the valve-shaped structure being densified and rigidized with a matrix of carbon containing discontinuous carbon fibers: and the finished valve being treated to resist oxidation. Also disclosed is a carbon matrix plug containing continuous and discontinuous carbon fibers and forming a net-shape valve head acting as a mandrel over which the unidirectional and braided carbon fibers are formed according to textile processes. Also disclosed are various preform valves and processes for making finished and preform carbon fiber reinforced carbon composite valves.

  9. Structural Diagnostics of CFRP Composite Aircraft Components by Ultrasonic Guided Waves and Built-In Piezoelectric Transducers

    Energy Technology Data Exchange (ETDEWEB)

    Matt, Howard M. [Univ. of California, San Diego, CA (United States)

    2006-01-01

    To monitor in-flight damage and reduce life-cycle costs associated with CFRP composite aircraft, an autonomous built-in structural health monitoring (SHM) system is preferred over conventional maintenance routines and schedules. This thesis investigates the use of ultrasonic guided waves and piezoelectric transducers for the identification and localization of damage/defects occurring within critical components of CFRP composite aircraft wings, mainly the wing skin-to-spar joints. The guided wave approach for structural diagnostics was demonstrated by the dual application of active and passive monitoring techniques. For active interrogation, the guided wave propagation problem was initially studied numerically by a semi-analytical finite element method, which accounts for viscoelastic damping, in order to identify ideal mode-frequency combinations sensitive to damage occurring within CFRP bonded joints. Active guided wave tests across three representative wing skin-to-spar joints at ambient temperature were then conducted using attached Macro Fiber Composite (MFC) transducers. Results from these experiments demonstrate the importance of intelligent feature extraction for improving the sensitivity to damage. To address the widely neglected effects of temperature on guided wave base damage identification, analytical and experimental analyses were performed to characterize the influence of temperature on guided wave signal features. In addition, statistically-robust detection of simulated damage in a CFRP bonded joint was successfully achieved under changing temperature conditions through a dimensionally-low, multivariate statistical outlier analysis. The response of piezoceramic patches and MFC transducers to ultrasonic Rayleigh and Lamb wave fields was analytically derived and experimentally validated. This theory is useful for designing sensors which possess optimal sensitivity toward a given mode-frequency combination or for predicting the frequency dependent

  10. A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries

    Science.gov (United States)

    McDonald, Robert C.; VanBlarcom, Shelly L.; Kwasnik, Katherine E.

    2013-01-01

    A document discusses a thin layer of composite material, made from nano scale particles of nickel and Teflon, placed within a battery cell as a layer within the anode and/or the cathode. There it conducts electrons at room temperature, then switches to an insulator at an elevated temperature to prevent thermal runaway caused by internal short circuits. The material layer controls excess currents from metal-to-metal or metal-to-carbon shorts that might result from cell crush or a manufacturing defect

  11. Carbon Fiber Reinforced Carbon Composites Rotary Valves for Internal Combustion Engines

    Science.gov (United States)

    Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    1999-01-01

    Carbon fiber reinforced carbon composite rotary, sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or warp-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties, do not present the sealing and lubrication problems that have prevented rotary, sleeve, and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  12. Carbon Fiber Reinforced Carbon Composite Rotary Valve for an Internal Combustion Engine

    Science.gov (United States)

    Northam, G.Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    2000-01-01

    Carbon fiber reinforced carbon composite rotary sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or wrap-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties do not present the sealing and lubrication problems that have prevented rotary sleeve and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  13. International differences in health care costs in Europe and the United States: Do these affect the cost-effectiveness of diagnostic strategies for pulmonary embolism?

    International Nuclear Information System (INIS)

    Erkel, A.R. van; Pattynama, P.M.T.; Hout, W.B. van den

    1999-01-01

    The aim of this study was to assess whether potential differences in costs for diagnostic procedures and treatment of pulmonary embolism (PE) among European and U. S. hospitals alter the optimal cost-effective diagnostic strategy for PE. A standardized questionnaire was used to obtain cost data for the diagnosis and treatment of PE in participating European and U. S. hospitals. Costs for diagnostic tests and treatment of PE were then calculated in a standardized manner for all participating hospitals, from the hospital perspective. Costs were used in an existing cost-effectiveness analysis (CEA) model to determine the most cost-effective diagnostic strategy in participating hospitals. There were considerable differences in costs for diagnostic and therapeutic procedures for PE among the participating centers. These differences, however, did not affect the most cost-effective strategy based on incremental cost-effectiveness. In all hospitals the most cost-effective strategy appeared to be ultrasound followed by helical CT. International differences in cost of diagnostic and therapeutic procedures certainly exist and should be considered before applying a published CEA. Nevertheless, despite these cost differences, the diagnostic strategy for PE of ultrasound followed by helical CT appears most cost-effective. (orig.)

  14. Complex regional pain syndrome type I : Use of the International Association for the Study of Pain diagnostic criteria defined in 1994

    NARCIS (Netherlands)

    Reinders, M.F.; Geertzen, J.H.B.; Dijkstra, P.U.

    2002-01-01

    Objectives: The objective was to assess the reported use in recent publications of the diagnostic criteria for complex regional pain syndrome type I (CRPS 1) proposed by the International Association for the Study of Pain (IASP) in 1994. Methods: A literature search of MEDLINE (January 1996 to July

  15. International patenting in ophthalmology: An analysis of its structure and relevance for the development of drugs and diagnostics

    Directory of Open Access Journals (Sweden)

    Hermann AM Mucke

    2008-10-01

    Full Text Available Hermann AM Mucke, Peter Mucke, Eva MuckeHM Pharma Consultancy, Vienna, AustriaAbstract: While investigative ophthalmologists access peer-reviewed journals as part of their daily routine, and while they regularly visit scientific congresses, they rarely peruse patent documents as an information source. Among the reasons for this negligence are the incompatibility of patent search algorithms with those known from journal databases, a legalistic and frequently redundant language, and misconceptions about the nature of the patenting system. Here we present key data and analyses from the ophthalmology module of a patent database system that we are developing to address some of these problems. We show that international patent applications consistently reflect developer interest in the ocular drug and diagnostics field; that they are technically focused lead indicators of developments that frequently feature in peer-reviewed patenting only much later; and that patenting targets are well aligned with the unmet therapeutic needs of populations in industrialized countries. Most applications (74%–78% in years since 2006 are supported with experimental data, and most (on average, 80%–90% faced at least one objection to patentability during their initial stage of examination. In contrast to the peer-reviewed scenery that is highly diverse, the corresponding patenting arena shows a pronounced focus on the United States.Keywords: ophthalmology, eye diseases, iontophoresis, intellectual property, patents as topic, bibliographic databases

  16. Development of an Internal Real-Time Wireless Diagnostic Tool for a Proton Exchange Membrane Fuel Cell.

    Science.gov (United States)

    Lee, Chi-Yuan; Chen, Chia-Hung; Tsai, Chao-Hsuan; Wang, Yu-Syuan

    2018-01-13

    To prolong the operating time of unmanned aerial vehicles which use proton exchange membrane fuel cells (PEMFC), the performance of PEMFC is the key. However, a long-term operation can make the Pt particles of the catalyst layer and the pollutants in the feedstock gas bond together (e.g., CO), so that the catalyst loses reaction activity. The performance decay and aging of PEMFC will be influenced by operating conditions, temperature, flow and CO concentration. Therefore, this study proposes the development of an internal real-time wireless diagnostic tool for PEMFC, and uses micro-electro-mechanical systems (MEMS) technology to develop a wireless and thin (PEMFC; (5) customized design and development. The flexible integrated microsensor is embedded in the PEMFC, three important physical quantities in the PEMFC, which are the temperature, flow and CO, can be measured simultaneously and instantly, so as to obtain the authentic and complete reaction in the PEMFC to enhance the performance of PEMFC and to prolong the service life.

  17. Development of an Internal Real-Time Wireless Diagnostic Tool for a Proton Exchange Membrane Fuel Cell

    Directory of Open Access Journals (Sweden)

    Chi-Yuan Lee

    2018-01-01

    Full Text Available To prolong the operating time of unmanned aerial vehicles which use proton exchange membrane fuel cells (PEMFC, the performance of PEMFC is the key. However, a long-term operation can make the Pt particles of the catalyst layer and the pollutants in the feedstock gas bond together (e.g., CO, so that the catalyst loses reaction activity. The performance decay and aging of PEMFC will be influenced by operating conditions, temperature, flow and CO concentration. Therefore, this study proposes the development of an internal real-time wireless diagnostic tool for PEMFC, and uses micro-electro-mechanical systems (MEMS technology to develop a wireless and thin (<50 μm flexible integrated (temperature, flow and CO microsensor. The technical advantages are (1 compactness and three wireless measurement functions; (2 elastic measurement position and accurate embedding; (3 high accuracy and sensitivity and quick response; (4 real-time wireless monitoring of dynamic performance of PEMFC; (5 customized design and development. The flexible integrated microsensor is embedded in the PEMFC, three important physical quantities in the PEMFC, which are the temperature, flow and CO, can be measured simultaneously and instantly, so as to obtain the authentic and complete reaction in the PEMFC to enhance the performance of PEMFC and to prolong the service life.

  18. Diagnostic and Prognostic Impact of pc-ASPECTS Applied to Perfusion CT in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Pallesen, Lars-Peder; Gerber, Johannes; Dzialowski, Imanuel; van der Hoeven, Erik J R J; Michel, Patrik; Pfefferkorn, Thomas; Ozdoba, Christoph; Kappelle, L Jaap; Wiedemann, Baerbel; Khomenko, Andrei; Algra, Ale; Hill, Michael D; von Kummer, Ruediger; Demchuk, Andrew M; Schonewille, Wouter J; Puetz, Volker

    2015-01-01

    The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality. Copyright © 2014 by the American Society of Neuroimaging.

  19. International society of sports nutrition position stand: diets and body composition.

    Science.gov (United States)

    Aragon, Alan A; Schoenfeld, Brad J; Wildman, Robert; Kleiner, Susan; VanDusseldorp, Trisha; Taylor, Lem; Earnest, Conrad P; Arciero, Paul J; Wilborn, Colin; Kalman, Douglas S; Stout, Jeffrey R; Willoughby, Darryn S; Campbell, Bill; Arent, Shawn M; Bannock, Laurent; Smith-Ryan, Abbie E; Antonio, Jose

    2017-01-01

    Position Statement: The International Society of Sports Nutrition (ISSN) bases the following position stand on a critical analysis of the literature regarding the effects of diet types (macronutrient composition; eating styles) and their influence on body composition. The ISSN has concluded the following. 1) There is a multitude of diet types and eating styles, whereby numerous subtypes fall under each major dietary archetype. 2) All body composition assessment methods have strengths and limitations. 3) Diets primarily focused on fat loss are driven by a sustained caloric deficit. The higher the baseline body fat level, the more aggressively the caloric deficit may be imposed. Slower rates of weight loss can better preserve lean mass (LM) in leaner subjects. 4) Diets focused primarily on accruing LM are driven by a sustained caloric surplus to facilitate anabolic processes and support increasing resistance-training demands. The composition and magnitude of the surplus, as well as training status of the subjects can influence the nature of the gains. 5) A wide range of dietary approaches (low-fat to low-carbohydrate/ketogenic, and all points between) can be similarly effective for improving body composition. 6) Increasing dietary protein to levels significantly beyond current recommendations for athletic populations may result in improved body composition. Higher protein intakes (2.3-3.1 g/kg FFM) may be required to maximize muscle retention in lean, resistance-trained subjects under hypocaloric conditions. Emerging research on very high protein intakes (>3 g/kg) has demonstrated that the known thermic, satiating, and LM-preserving effects of dietary protein might be amplified in resistance-training subjects. 7) The collective body of intermittent caloric restriction research demonstrates no significant advantage over daily caloric restriction for improving body composition. 8) The long-term success of a diet depends upon compliance and suppression or

  20. Body Composition and Survival in Dialysis Patients: Results from an International Cohort Study

    Science.gov (United States)

    Usvyat, Len A.; Kotanko, Peter; Bayh, Inga; Canaud, Bernard; Etter, Michael; Gatti, Emanuele; Grassmann, Aileen; Wang, Yuedong; Marelli, Cristina; Scatizzi, Laura; Stopper, Andrea; van der Sande, Frank M.; Kooman, Jeroen

    2015-01-01

    Background and objectives High body mass index appears protective in hemodialysis patients, but uncertainty prevails regarding which components of body composition, fat or lean body mass, are primarily associated with survival. Design, setting, participants, & measurements Data between April 2006 and December 2012 were extracted from the Fresenius Medical Care Europe subset of the international MONitoring Dialysis Outcomes initiative. Fresenius Medical Care Europe archives a unique repository of predialysis body composition measurements determined by multifrequency bioimpedance (BCM Body Composition Monitor). The BCM Body Composition Monitor reports lean tissue indices (LTIs) and fat tissue indices (FTIs), which are the respective tissue masses normalized to height squared, relative to an age- and sex-matched healthy population. The relationship between LTI and FTI and all-cause mortality was studied by Kaplan–Meier analysis, multivariate Cox regression, and smoothing spline ANOVA logistic regression. Results In 37,345 hemodialysis patients, median (25th–75th percentile) LTI and FTI were 12.2 (10.3–14.5) and 9.8 (6.6–12.4) kg/m2, respectively. Median (25th–75th percentile) follow-up time was 266 (132–379) days; 3458 (9.2%) patients died during follow-up. Mortality was lowest with both LTI and FTI in the 10th–90th percentile (reference group) and significantly higher at the lower LTI and FTI extreme (hazard ratio [HR], 3.37; 95% confidence interval [95% CI], 2.94 to 3.87; P<0.001). Survival was best with LTI between 15 and 20 kg/m2 and FTI between 4 and 15 kg/m2 (probability of death during follow-up: <5%). When taking the relation between both compartments into account, the interaction was significant (P=0.01). Higher FTI appeared protective in patients with low LTI (HR, 3.37; 95% CI, 2.94 to 3.87; P<0.001 at low LTI–low FTI, decreasing to HR, 1.79; 95% CI, 1.47 to 2.17; P<0.001 at low LTI–high FTI). Conclusions This large international study

  1. Internal control for real-time polymerase chain reaction based on MS2 bacteriophage for RNA viruses diagnostics.

    Science.gov (United States)

    Zambenedetti, Miriam Ribas; Pavoni, Daniela Parada; Dallabona, Andreia Cristine; Dominguez, Alejandro Correa; Poersch, Celina de Oliveira; Fragoso, Stenio Perdigão; Krieger, Marco Aurélio

    2017-05-01

    Real-time reverse transcription polymerase chain reaction (RT-PCR) is routinely used to detect viral infections. In Brazil, it is mandatory the use of nucleic acid tests to detect hepatitis C virus (HCV), hepatitis B virus and human immunodeficiency virus in blood banks because of the immunological window. The use of an internal control (IC) is necessary to differentiate the true negative results from those consequent from a failure in some step of the nucleic acid test. The aim of this study was the construction of virus-modified particles, based on MS2 bacteriophage, to be used as IC for the diagnosis of RNA viruses. The MS2 genome was cloned into the pET47b(+) plasmid, generating pET47b(+)-MS2. MS2-like particles were produced through the synthesis of MS2 RNA genome by T7 RNA polymerase. These particles were used as non-competitive IC in assays for RNA virus diagnostics. In addition, a competitive control for HCV diagnosis was developed by cloning a mutated HCV sequence into the MS2 replicase gene of pET47b(+)-MS2, which produces a non-propagating MS2 particle. The utility of MS2-like particles as IC was evaluated in a one-step format multiplex real-time RT-PCR for HCV detection. We demonstrated that both competitive and non-competitive IC could be successfully used to monitor the HCV amplification performance, including the extraction, reverse transcription, amplification and detection steps, without compromising the detection of samples with low target concentrations. In conclusion, MS2-like particles generated by this strategy proved to be useful IC for RNA virus diagnosis, with advantage that they are produced by a low cost protocol. An attractive feature of this system is that it allows the construction of a multicontrol by the insertion of sequences from more than one pathogen, increasing its applicability for diagnosing different RNA viruses.

  2. SU-F-I-61: Assessment and Characterization of the Built-in Internal Photometer of Primary Diagnostic Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Ruuge, A; Erdi, Y; Mahmood, U [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: The conformance of Primary Diagnostic Monitors (PDMs) to the DICOM GSDF is increasingly required by several state and city regulators. Our purpose was to quantitatively characterize the luminance performance of the internal, built in photometer of BARCO monitors against an externally calibrated luminance meter. Methods: Thirty one PDMs (BARCO) were included in our analysis. An externally calibrated photometer (RaySafe Solo Light) was used to measure the luminance and illuminance values. Measured monitors were located at various hospital sites, radiology physicians’ offices and radiology reading rooms. All measured PDMs were equipped with the manufacturer’s built-in photometers and connected to Barco MediCal QA web service for manual and automatic quality control measurements. PDM combinations included 1, 2 and 4 monitors depending on the location. TG-18 and SMPTE test patterns were used to evaluate monitor performance. Results: All the PDMs exceeded the luminance ratio of 250:1, as required by NYC PDM guidelines. One PDM failed the NYC requirement for the minimal luminance level of 350 cd/m2. As compared to the external photometer, the difference in measurement of the maximum luminance with the built-in photometer was found to exceed 5% on 6 of the PDM measured, with a maximum deviation of 10%. The age of the monitors that failed was on average 5 years. All monitors passed the luminance uniformity test, which was 30% from the center of the monitor to the 4 corner locations. Four PDMs failed the Gray Scale Display Function (GSDF) calibration. Conclusion: For the consistent display of medical images and continued conformance with the DICOM GSDF standard, it is essential to compare the performance of the built-in photometer with an externally calibrated photometer for monitors that are older than 5 years.

  3. Results of the international Pu-2000 exercise for plutonium isotopic composition measurements

    International Nuclear Information System (INIS)

    Morel, J.; Bickel, M.; Hill, C.; Verbruggen, A.

    2004-01-01

    An international comparison for plutonium isotopic composition measurement, known as the Pu-2000 exercise, was organized by the ESARDA NDA-WG (European Safeguards Research and Development Association, Working Group on Techniques and Standards for Non-Destructive Assay). The aim of this comparison was to test X- and γ-ray spectrometry methods over a large range of isotopic ratios. These methods are based on the complex analysis of several X- and γ-rays in the KX region of the plutonium spectrum and also in the 120-700 keV energy range. The results obtained by the participants with their corresponding uncertainties are presented in this document and compared to the declared values. The main conclusions of the work are also given. No important bias due to an inadequate knowledge of the nuclear data for plutonium isotopes was observed

  4. Revisiting Classification of Eating Disorders-toward Diagnostic and Statistical Manual of Mental Disorders-5 and International Statistical Classification of Diseases and Related Health Problems-11.

    Science.gov (United States)

    Goyal, Shrigopal; Balhara, Yatan Pal Singh; Khandelwal, S K

    2012-07-01

    Two of the most commonly used nosological systems- International Statistical Classification of Diseases and Related Health Problems (ICD)-10 and Diagnostic and Statistical Manual of Mental Disorders (DSM)-IV are under revision. This process has generated a lot of interesting debates with regards to future of the current diagnostic categories. In fact, the status of categorical approach in the upcoming versions of ICD and DSM is also being debated. The current article focuses on the debate with regards to the eating disorders. The existing classification of eating disorders has been criticized for its limitations. A host of new diagnostic categories have been recommended for inclusion in the upcoming revisions. Also the structure of the existing categories has also been put under scrutiny.

  5. Brucella abortus choloylglycine hydrolase affects cell envelope composition and host cell internalization.

    Directory of Open Access Journals (Sweden)

    María Inés Marchesini

    Full Text Available Choloylglycine hydrolase (CGH, E.C. 3.5.1.24 is a conjugated bile salt hydrolase that catalyses the hydrolysis of the amide bond in conjugated bile acids. Bile salt hydrolases are expressed by gastrointestinal bacteria, and they presumably decrease the toxicity of host's conjugated bile salts. Brucella species are the causative agents of brucellosis, a disease affecting livestock and humans. CGH confers Brucella the ability to deconjugate and resist the antimicrobial action of bile salts, contributing to the establishment of a successful infection through the oral route in mice. Additionally, cgh-deletion mutant was also attenuated in intraperitoneally inoculated mice, which suggests that CGH may play a role during systemic infection other than hydrolyzing conjugated bile acids. To understand the role CGH plays in B. abortus virulence, we infected phagocytic and epithelial cells with a cgh-deletion mutant (Δcgh and found that it is defective in the internalization process. This defect along with the increased resistance of Δcgh to the antimicrobial action of polymyxin B, prompted an analysis of the cell envelope of this mutant. Two-dimensional electrophoretic profiles of Δcgh cell envelope-associated proteins showed an altered expression of Omp2b and different members of the Omp25/31 family. These results were confirmed by Western blot analysis with monoclonal antibodies. Altogether, the results indicate that Brucella CGH not only participates in deconjugation of bile salts but also affects overall membrane composition and host cell internalization.

  6. Parametric study on nonlinear vibration of composite truss core sandwich plate with internal resonance

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jia Nen; Liu, Jun [Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin (China); Zhang, Wei; Yao, Ming Hui [College of Mechanical Engineering, Beijing University of Technology, Beijing (China); Sun, Min [School of Science, Tianjin Chengjian University, Tianjin (China)

    2016-09-15

    Nonlinear vibrations of carbon fiber reinforced composite sandwich plate with pyramidal truss core are investigated. The governing equation of motion for the sandwich plate is derived by using a Zig-Zag theory under consideration of geometrically nonlinear. The natural frequencies of sandwich plates with different dimensions are calculated and compared with those obtained from the classic laminated plate theory and Reddy's third-order shear deformation plate theory. The frequency responses and waveforms of the sandwich plate when 1:3 internal resonance occurs are obtained, and the characteristics of the internal resonance are discussed. The influences of layer number of face sheet, strut radius, core height and inclination angle on the nonlinear responses of the sandwich plate are analyzed. The results demonstrate that the strut radius and inclination angle mainly affect the resonance frequency band of the sandwich plate, and the layer number and core height not only influence the resonance frequency band but also significantly affect the response amplitude.

  7. Evaluation of internal adaptation of Class V resin composite restorations using three techniques of polymerization

    Directory of Open Access Journals (Sweden)

    José Carlos Pereira

    2007-02-01

    Full Text Available OBJECTIVE: The purpose of this in vitro study was to evaluate the internal adaptation of Class V composite restorations to the cavity walls using three different techniques of polymerization. METHODS: Standard cavities were prepared on the buccal and lingual surfaces of 24 extracted human third molars with margins located above and below the cementoenamel junction. Restorations were placed in one increment using two restorative systems: 3M Filtek A110/ Single Bond (M and 3M Filtek Z250/ Single Bond (H in the same tooth, randomly in the buccal and lingual surfaces. Resin composites were polymerized using three techniques: Group 1 - Conventional (60 s - 600 mW/cm²; Group 2 - Soft-start (20 s - 200 mW/cm² , 40 s - 600 mW/cm²; Group 3 - Pulse Activation (3 s - 200 mW/cm², 3-min hiatus, 57 s - 600 mW/cm². Buccolingual sections were polished, impressions taken and replicated. Specimens were assessed under scanning electron microscopy up to X1000 magnification. Scores were given for presence or absence of gaps (0 - no gap; 1 - gap in one wall; 2 - gap in two walls; 3 - gap in three walls. RESULTS: The mean scores of the groups were (±SD were: G1M-3.0 (± 0.0; G2M-2.43 (± 0.8; G3M- 1.71 (± 0.9; G1H- 2.14 (± 1.2; G2H- 2.00 (± 0.8; G3H- 1.67 (± 1.1. Data were analyzed using Kruskal-Wallis and Dunnet's tests. No statistically significant difference (p>0.05 was found among groups. Gaps were observed in all groups. CONCLUSIONS: The photocuring technique and the type of resin composite had no influence on the internal adaptation of the material to the cavity walls. A positive effect was observed when the slow polymerization techniques were used.

  8. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  9. Elementos diagnósticos en medicina interna 2003-2010 Diagnostics elements in internal medicine 2003-2010

    Directory of Open Access Journals (Sweden)

    Jordi Delás

    2012-09-01

    Full Text Available Introducción. Desde el curso 2003-2004 impartimos en la Facultad de Medicina de la Universitat de Barcelona la asignatura optativa semipresencial 'Elementos diagnósticos en medicina interna', en la que se aborda el diagnóstico a través de análisis de laboratorio, pruebas funcionales, de imagen y electrocardiografía. Materiales y métodos. Tras las sesiones presenciales, el material docente se deposita en la página web o campus virtual de la asignatura, a partir del cual los estudiantes responden a seis cuestionarios. Resultados. En el curso 2008-2009 se matricularon 61 alumnos de cuarto a sexto curso. Veintisiete alumnos (44,26% respondieron correctamente a más de la mitad de las preguntas, el 31,15% no alcanzó esta cifra y el 24,59% no completó el programa de evaluaciones. Las puntuaciones más altas se han dado de las pruebas funcionales respiratorias, y las más bajas, en la evaluación de la radiografía de tórax. Conclusiones. No es fácil la evaluación de competencias clínicas. El coste de realización de las pruebas y la resistencia de los estudiantes a ser evaluados quedan soslayados en esta experiencia, donde los estudiantes se matriculan voluntariamente. La sencillez del proyecto permitiría evaluar en competencias clínicas a todos los estudiantes de la facultad en los cursos clínicos cuando aún es posible la formación. Una vez comprobado que los estudiantes tienen una buena aceptación del sistema propuesto, se podría diseñar un sistema de acceso a créditos docentes y un plan de formación específica en las materias no superadas.Introduction. From the course 2003-2004, we give in the Faculty of Medicine of the University of Barcelona a matter called Diagnostics Elements in Internal Medicine, for the diagnostic through analysis of laboratory, functional proofs, of image and electrocardiogram. Materials and methods. All the educational material is deposited in the page web of the topic and through it the students

  10. Internal control for real-time polymerase chain reaction based on MS2 bacteriophage for RNA viruses diagnostics

    Directory of Open Access Journals (Sweden)

    Miriam Ribas Zambenedetti

    Full Text Available BACKGROUND Real-time reverse transcription polymerase chain reaction (RT-PCR is routinely used to detect viral infections. In Brazil, it is mandatory the use of nucleic acid tests to detect hepatitis C virus (HCV, hepatitis B virus and human immunodeficiency virus in blood banks because of the immunological window. The use of an internal control (IC is necessary to differentiate the true negative results from those consequent from a failure in some step of the nucleic acid test. OBJECTIVES The aim of this study was the construction of virus-modified particles, based on MS2 bacteriophage, to be used as IC for the diagnosis of RNA viruses. METHODS The MS2 genome was cloned into the pET47b(+ plasmid, generating pET47b(+-MS2. MS2-like particles were produced through the synthesis of MS2 RNA genome by T7 RNA polymerase. These particles were used as non-competitive IC in assays for RNA virus diagnostics. In addition, a competitive control for HCV diagnosis was developed by cloning a mutated HCV sequence into the MS2 replicase gene of pET47b(+-MS2, which produces a non-propagating MS2 particle. The utility of MS2-like particles as IC was evaluated in a one-step format multiplex real-time RT-PCR for HCV detection. FINDINGS We demonstrated that both competitive and non-competitive IC could be successfully used to monitor the HCV amplification performance, including the extraction, reverse transcription, amplification and detection steps, without compromising the detection of samples with low target concentrations. In conclusion, MS2-like particles generated by this strategy proved to be useful IC for RNA virus diagnosis, with advantage that they are produced by a low cost protocol. An attractive feature of this system is that it allows the construction of a multicontrol by the insertion of sequences from more than one pathogen, increasing its applicability for diagnosing different RNA viruses.

  11. Composites

    International Nuclear Information System (INIS)

    Kasen, M.B.

    1983-01-01

    This chapter discusses the roles of composite laminates and aggregates in cryogenic technology. Filamentary-reinforced composites are emphasized because they are the most widely used composite materials. Topics considered include composite systems and terminology, design and fabrication, composite failure, high-pressure reinforced plastic laminates, low-pressure reinforced plastics, reinforced metals, selectively reinforced structures, the effect of cryogenic temperatures, woven-fabric and random-mat composites, uniaxial fiber-reinforced composites, composite joints in cryogenic structures, joining techniques at room temperature, radiation effects, testing laminates at cryogenic temperatures, static and cyclic tensile testing, static and cyclic compression testing, interlaminar shear testing, secondary property tests, and concrete aggregates. It is suggested that cryogenic composite technology would benefit from the development of a fracture mechanics model for predicting the fitness-for-purpose of polymer-matrix composite structures

  12. Atomic structures and compositions of internal interfaces. Progress report, September 1, 1991--August 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Seidman, D.N. [Northwestern Univ., Evanston, IL (United States). Dept. of Materials Science and Engineering; Merkle, K.L. [Argonne National Lab., IL (United States)

    1992-03-01

    This research program addresses fundamental questions concerning the relationships between atomic structures and chemical compositions of metal/ceramic heterophase interfaces. The chemical composition profile across a Cu/MgO {l_brace}111{r_brace}-type heterophase interface, produced by the internal oxidation of a Cu(Mg) single phase alloy, is measured via atom-probe field-ion microscopy with a spatial resolution of 0.121 nm; this resolution is equal to the interplanar space of the {l_brace}222{r_brace} MgO planes. In particular, we demonstrate for the first time that the bonding across a Cu/MgO {l_brace}111{r_brace}-type heterophase interface, along a <111> direction common to both the Cu matrix and an MgO precipitate, has the sequence Cu{vert_bar}O{vert_bar}Mg{hor_ellipsis} and not Cu{vert_bar}Mg{vert_bar}O{hor_ellipsis}; this result is achieved without any deconvolution of the experimental data. Before determining this chemical sequence it was established, via high resolution electron microscopy, that the morphology of an MgO precipitate in a Cu matrix is an octahedron faceted on {l_brace}111{r_brace} planes with a cube-on-cube relationship between a precipitate and the matrix. First results are also presented for the Ni/Cr{sub 2}O{sub 4} interface; for this system selected area atom probe microscopy was used to analyze this interface; Cr{sub 2}O{sub 4} precipitates are located in a field-ion microscope tip and a precipitate is brought into the tip region via a highly controlled electropolishing technique.

  13. Strength and thermal stability of Cu-Al2O3 composite obtained by internal oxidation

    Directory of Open Access Journals (Sweden)

    Jovanovic, M. T.

    2010-12-01

    Full Text Available The objective of the work is to study the effects of the high-energy milling on strengthening, thermal stability and electrical conductivity of Cu-Al2O3 composite. The prealloyed copper powders, atomized in inert gas and containing 3 wt. % Al, were milled up to 20 h in the planetary ball mill to oxidize in situ aluminium with oxygen from the air. Composite compacts were obtained by hot-pressing in an argon atmosphere at 800 °C for 3 h under the pressure of 35MPa. The microstructural characterization was performed by the optical microscope, scanning electron microscope (SEM, transmission electron microscope (TEM and X-ray diffraction analysis (XRD. The microhardness, electrical conductivity and density measurements were also carried out. The effect of internal oxidation and high-energy milling on strengthening of Cu-Al2O3 composite was significant, The increase of the microhardness of composite compacts (292 HV is almost threefold comparing to compacts processed from the as-received Cu-3 wt. % Al powder (102 HV. The grain size of Cu-Al2O3 compacts processed from 5 and 20 h-milled powders was 75 and 45 nm, respectively. The small increase in the grain size and the small microhardness drop indicate the high thermal stability of Cu-Al2O3 composite during high-temperature exposure at 800 °C.El objetivo del trabajo es el estudio de los efectos de la pulverización con altas energías sobre la resistencia, estabilidad térmica y conductividad eléctrica del compuesto Cu-Al2O3. El polvo pre-aleado de cobre, obtenido a través de la atomización con gas inerte y con un contenido de 3wt. % Al, se molió durante 20 h en el molino planetario de bolas dando lugar a la oxidación in situ del aluminio con el oxígeno del aire. El compuesto compactado se ha obtenido mediante prensado en caliente en atmósfera de argón a 800 °C durante 3 h y a una presión de 35MPa. La caracterización microestructural se hizo a través de microscopia óptica, microscopia

  14. Internal and Marginal Fit of Modern Indirect Class II Composite Inlays

    Directory of Open Access Journals (Sweden)

    Philipp C. Pott

    2014-06-01

    Full Text Available Introduction: This in vitro study investigates the marginal and internal fit of indirect class II composite restorations. Two different processes for chair-side restorations were compared. In group A, the restorations were fabricated using CAD/CAM technology (Cerec, Sirona, Germany, Bernsheim and in group B they were made by hand (GrandioSO Inlay System, VOCO GmbH, Germany, Cuxhaven. Methods: For a metal tooth with a MOD cavity each 10 restorations were made for groups A and B. For each restoration, a replica of the cement-gap made from light body silicone was produced by placing the restoration into the cavity of the metal tooth. For this purpose, a special restoration-positioning machine was developed. Each replica was sectioned off in the longitudinal axis (L and in the cross axis (C. The thickness of the replicas was measured in both directions, using picture analysis software under a light reflection microscope. To evaluate the fit of the restorations, a special fitting parameter was calculated. Statistical analysis was performed with the t test. Results: The fitting-parameter in group B (L: 97.6µm±73.0µm; C: 71.8µm±46.4µm was significantly lower than that of group A (L: 155.1µm±102.3.0µm; C: 168.2µm±91.9µm (P

  15. Preparation of ring-shaped composite bonded magnets with continuously controlled anisotropy distribution for internal space

    International Nuclear Information System (INIS)

    Yamashita, F; Yamada, O; Ohya, S; Kobayashi, O; Nakano, M; Fukunaga, H

    2010-01-01

    We have already reported an advanced method for producing a radially-anisotropic rare earth composite bonded magnet with continuously controlled direction of anisotropy. The magnet has been applied to an inner rotor as a practical usage. In this study, the outstanding preparation method was adopted into the preparation of a magnet applied for an outer rotor. An optimized condition of extrusion and compaction at an elevated temperature could be obtained. In addition, a low pressure configuration to the ring-shaped magnet from plural preformed magnets was carried out, which had specific distribution of magnetic anisotropy for internal space for a small motor, by using self recoverability based on the viscous deformation without an alignment field. No deterioration of magnetic properties was detected through the process even if those magnets were miniaturized. Resultantly, the (BH) max of a ring-shaped magnet with the continuously controlled direction of magnetic anisotropy attained the value of 186 kJ/m 3 , and we obtained sine-wave magnetic anisotropy distribution, even if those magnets were miniaturized.

  16. Crosslinguistic Developmental Consistency in the Composition of Toddlers’ Internal State Vocabulary: Evidence from Four Languages

    Directory of Open Access Journals (Sweden)

    Susanne Kristen

    2014-01-01

    Full Text Available Mental state language, emerging in the second and third years of life in typically developing children, is one of the first signs of an explicit psychological understanding. While mental state vocabulary may serve a variety of conversational functions in discourse and thus might not always indicate psychological comprehension, there is evidence for genuine references to mental states (desires, knowledge, beliefs, and emotions early in development across languages. This present study presents parental questionnaire data on the composition of 297 toddler-aged (30-to 32-month-olds children’s internal state vocabulary in four languages: Italian, German, English, and French. The results demonstrated that across languages expressions for physiological states (e.g., hungry and tired were among the most varied, while children’s vocabulary for cognitive entities (e.g., know and think proved to be least varied. Further, consistent with studies on children’s comprehension of these concepts, across languages children’s mastery of volition terms (e.g., like to do and want preceded their mastery of cognition terms. These findings confirm the cross-linguistic consistency of children’s emerging expression of abstract psychological concepts.

  17. Composition

    DEFF Research Database (Denmark)

    Bergstrøm-Nielsen, Carl

    2011-01-01

    Strategies are open compositions to be realised by improvising musicians. See more about my composition practise in the entry "Composition - General Introduction". Caution: streaming the sound files will in some cases only provide a few minutes' sample. Please DOWNLOAD them to hear them in full...

  18. Composition

    DEFF Research Database (Denmark)

    2014-01-01

    Memory Pieces are open compositions to be realised solo by an improvising musicians. See more about my composition practise in the entry "Composition - General Introduction". Caution: streaming the sound files will in some cases only provide a few minutes' sample. Please DOWNLOAD them to hear them...

  19. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    Science.gov (United States)

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  20. The Effect of Question Format and Task Difficulty on Reasoning Strategies and Diagnostic Performance in Internal Medicine Residents

    Science.gov (United States)

    Heemskerk, Laura; Norman, Geoff; Chou, Sophia; Mintz, Marcy; Mandin, Henry; McLaughlin, Kevin

    2008-01-01

    Background: Previous studies have suggested an association between reasoning strategies and diagnostic success, but the influence on this relationship of variables such as question format and task difficulty, has not been studied. Our objective was to study the association between question format, task difficulty, reasoning strategies and…

  1. CLASSIFICATION OF TEMPOROMANDIBULAR-JOINT OSTEOARTHROSIS AND INTERNAL DERANGEMENT .1. DIAGNOSTIC-SIGNIFICANCE OF CLINICAL AND RADIOGRAPHIC SYMPTOMS AND SIGNS

    NARCIS (Netherlands)

    STEGENGA, B; DEBONT, LGM; VANDERKUIJL, B; BOERING, G

    In the clinical setting, diagnosis primarily depends on the history and present status of the patient, and on the examiner's expertise in physical examination and interpretation of conventional radiographs. In order to evaluate the diagnostic significance of clinical and radiographic variables, the

  2. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 - 2016 Ebola outbreak in West Africa.

    Science.gov (United States)

    Ellerbrok, Heinz; Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-05-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied.

  3. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 - 2016 Ebola outbreak in West Africa.

    Directory of Open Access Journals (Sweden)

    Heinz Ellerbrok

    2017-05-01

    Full Text Available During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied.

  4. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 – 2016 Ebola outbreak in West Africa

    Science.gov (United States)

    Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-01-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied. PMID:28459810

  5. 4TH International Conference on High-Temperature Ceramic Matrix Composites

    National Research Council Canada - National Science Library

    2001-01-01

    .... Topic to be covered include fibers, interfaces, interphases, non-oxide ceramic matrix composites, oxide/oxide ceramic matrix composites, coatings, and applications of high-temperature ceramic matrix...

  6. Self-Supporting Nanoclay as Internal Scaffold Material for Direct Printing of Soft Hydrogel Composite Structures in Air.

    Science.gov (United States)

    Jin, Yifei; Liu, Chengcheng; Chai, Wenxuan; Compaan, Ashley; Huang, Yong

    2017-05-24

    Three dimensional (3D) bioprinting technology enables the freeform fabrication of complex constructs from various hydrogels and is receiving increasing attention in tissue engineering. The objective of this study is to develop a novel self-supporting direct hydrogel printing approach to extrude complex 3D hydrogel composite structures in air without the help of a support bath. Laponite, a member of the smectite mineral family, is investigated to serve as an internal scaffold material for the direct printing of hydrogel composite structures in air. In the proposed printing approach, due to its yield-stress property, Laponite nanoclay can be easily extruded through a nozzle as a liquid and self-supported after extrusion as a solid. Its unique crystal structure with positive and negative charges enables it to be mixed with many chemically and physically cross-linked hydrogels, which makes it an ideal internal scaffold material for the fabrication of various hydrogel structures. By mixing Laponite nanoclay with various hydrogel precursors, the hydrogel composites retain their self-supporting capacity and can be printed into 3D structures directly in air and retain their shapes before cross-linking. Then, the whole structures are solidified in situ by applying suitable cross-linking stimuli. The addition of Laponite nanoclay can effectively improve the mechanical and biological properties of hydrogel composites. Specifically, the addition of Laponite nanoclay results in a significant increase in the Young's modulus of each hydrogel-Laponite composite: 1.9-fold increase for the poly(ethylene glycol) diacrylate (PEGDA)-Laponite composite, 7.4-fold increase for the alginate-Laponite composite, and 3.3-fold increase for the gelatin-Laponite composite.

  7. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  8. Assessing the damage importance rank in acoustic diagnostics of technical conditions of the internal combustion engine with multi-valued logical decision trees

    Directory of Open Access Journals (Sweden)

    Deptuła Adam

    2017-01-01

    Full Text Available This paper presents possible applications of acoustic diagnostics in inspecting the technical condition of an internal combustion engine with autoignition on the example of the Fiat drive unit with the common rail system. As a result of measuring the sound pressure level for specific faults and comparing the noise generated by the motor running smoothly, the detailed maps of changes in the acoustic spectrum may be generated. These results may be helpful in future diagnostics of internal combustion engines. In the paper, we present the results from the scientific works in the area of research, design and operation of internal combustion engines, conducted at the Department of Automotive Engineering, in cooperation with the Laboratory of Hydraulic Drives & Vibroacoustics of Machines at the Wroclaw University of Technology. The broader study has so far allowed us to develop an authoritative method of identifying the type of engine damage using gametree structures. The present works assess the possibility of using multi-valued logic trees.

  9. International telepathology consultation: Three years of experience between the University of Pittsburgh Medical Center and KingMed Diagnostics in China

    Directory of Open Access Journals (Sweden)

    Chengquan Zhao

    2015-01-01

    Full Text Available Background: Telepathology is increasingly being employed to support diagnostic consultation services. Prior publications have addressed technology aspects for telepathology, whereas this paper will address the clinical telepathology experience of KingMed Diagnostics, the largest independent pathology medical laboratory in China. Beginning in 2012 the University of Pittsburgh Medical Center (UPMC and KingMed Diagnostics partnered to establish an international telepathology consultation service. Materials and Methods: This is a retrospective study that summarizes the telepathology experience and diagnostic consultation results between UPMC and KingMed over a period of 3 years from January 2012 to December 2014. Results: A total of 1561 cases were submitted for telepathology consultation including 144 cases in 2012, 614 cases in 2013, and 803 in 2014. Most of the cases (61.4% submitted were referred by pathologists, 36.9% by clinicians, and 1.7% by patients in China. Hematopathology received the most cases (23.7%, followed by bone/soft tissue (21.0% and gynecologic/breast (20.2% subspecialties. Average turnaround time (TAT per case was 5.4 days, which decreased from 6.8 days in 2012 to 5.0 days in 2014. Immunostains were required for most of the cases. For some difficult cases, more than one round of immunostains was needed, which extended the TAT. Among 855 cases (54.7% where a primary diagnosis or impression was provided by the referring local hospitals in China, the final diagnoses rendered by UPMC pathologists were identical in 25.6% of cases and significantly modified (treatment plan altered in 50.8% of cases. Conclusion: These results indicate that international telepathology consultation can significantly improve patient care by facilitating access to pathology expertise. The success of this international digital consultation service was dependent on strong commitment and support from leadership, information technology expertise, and

  10. Material toughness, internal structure, and caldera-collapse frequencies in basaltic and composite edifices

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, Agust [Department of Earth Sciences, Queen' s Building, Royal Holloway University of London, Egham TW20 OEX (United Kingdom)], E-mail: a.gudmundsson@es.rhul.ac.uk

    2008-10-01

    Formation of, and slip on existing, collapse calderas is much more common in basaltic edifices than in composite edifices. I suggest that this difference is partly due to the composite edifices being tougher and more resistant to ring-fault formation than a basaltic edifices. The high matieral toughness of composite edifices is related to their being composed of rock layers with widely different elastic properties, the elastic mismatch promoting deflection and/or arrest of potential ring faults at layer contacts.

  11. [An exploratory study on the diagnostic cutoff value of International HIV-associated Dementia Scale in minority ethnic groups with different educational levels, in Guangxi].

    Science.gov (United States)

    Zhao, Ting-ting; Feng, Qi-ming; Liang, Hao; Tang, Xian-yan; Wei, Bo

    2011-11-01

    Using Intelligence Scale of Mini Mental State Estimated (MMSE) as the gold standard to determine the relevance of International HIV-associated Dementia Scale (IHDS) in minority ethnic areas in Guangxi populations with different cultural values. Corresponding boundary value related to the authenticity and reliability on IHDS were also evaluated. 200 patients with HIV infection were randomly selected from the minority ethnic groups in Guangxi. For each infected person, MMSE and IHDS blind scale were tested at the same period. Using the results from MMSE scale test as the gold standard, ROC curve and IHDS scale in Guangxi minority populations with different education levels which related to the diagnosis of dementia-HIV values were determined. The value of a specific sector under the IHDS sensitivity, specificity, and internal consistency coefficients was also evaluated. When considering the infected person did not differ on their educational level, the IHDS scale diagnostic cutoff appeared as 8.25, while IHDS sensitivity as 0.925, specificity as 0.731 and Kappa as 0.477 (P education groups showed different IHDS diagnostic cutoff values. People with high school, secondary school or higher education levels, the IHDS diagnosis appeared to be 8.25, when sensitivity was 0.917, specificity was 0.895 and Kappa was 0.722 (P education level, the IHDS appeared to be 7.25. When sensitivity was 0.875, specificity was 0.661 and Kappa was 0.372 (P value (IHDS ≤ 10 points). When using IHDS to perform the HIV related dementia screening program, in the minority areas of Guangxi, culture context, the degree and difference of HIV infection should be considered, especially in using IHDS diagnostic cutoff values.

  12. Shareholder composition, share turnover, and returns in volatile markets : The case of international REITs

    NARCIS (Netherlands)

    Brounen, Dirk; Kok, N.; Ling, D.C.

    2012-01-01

    The shareholder composition of listed property companies has changed from the fragmented, retail ownership, to more concentrated, institutional ownership over the past decade. In this paper, we first document significant variation in the composition of the shareholder base across the world's five

  13. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J; Haythornthwaite, Jennifer A; Hollender, Lars; Jensen, Rigmor; John, Mike T; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M; Nixdorf, Donald R; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M; Zakrzewska, Joanna; Dworkin, Samuel F

    2014-01-01

    The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project-the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra

  14. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0

  15. Composition

    DEFF Research Database (Denmark)

    Bergstrøm-Nielsen, Carl

    2014-01-01

    Cue Rondo is an open composition to be realised by improvising musicians. See more about my composition practise in the entry "Composition - General Introduction". Caution: streaming the sound/video files will in some cases only provide a few minutes' sample, or the visuals will not appear at all....... Please DOWNLOAD them to see/hear them in full length! This work is licensed under a Creative Commons "by-nc" License. You may for non-commercial purposes use and distribute it, performance instructions as well as specially designated recordings, as long as the author is mentioned. Please see http...

  16. Validation of cytogenetic risk groups according to International Prognostic Scoring Systems by peripheral blood CD34+FISH: results from a German diagnostic study in comparison with an international control group.

    Science.gov (United States)

    Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A N; Lübbert, Michael; Greenberg, Peter L; Bennett, John M; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L; Ohyashiki, Kazuma; Le Beau, Michelle M; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie

    2015-02-01

    International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%-20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34(+)) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34(+) peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34(+) blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). Copyright© Ferrata Storti Foundation.

  17. Validation of cytogenetic risk groups according to International Prognostic Scoring Systems by peripheral blood CD34+FISH: results from a German diagnostic study in comparison with an international control group

    Science.gov (United States)

    Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H.; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A. N.; Lübbert, Michael; Greenberg, Peter L.; Bennett, John M.; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L.; Ohyashiki, Kazuma; Le Beau, Michelle M.; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R.; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie

    2015-01-01

    International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%–20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34+) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34+ peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34+ blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). PMID:25344522

  18. Correlation of precursor and product ions in single-stage high resolution mass spectrometry. A tool for detecting diagnostic ions and improving the precursor elemental composition elucidation

    Energy Technology Data Exchange (ETDEWEB)

    Borràs, S. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain); Kaufmann, A., E-mail: anton.kaufmann@klzh.ch [Official Food Control Authority, Fehrenstrasse 15, 8032 Zürich (Switzerland); Companyó, R. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain)

    2013-04-15

    Highlights: ► We are describing a technique to spot ions which are derived from each other. ► Single stage high resolution data is used. ► This “in silicon” technique is compared to conventional precursor scan. ► Some applications for this technique are presented. -- Abstract: Monitoring of common diagnostic fragments is essential for recognizing molecules which are members of a particular compound class. Up to now, unit resolving tandem quadrupole mass spectrometers, operating in the precursor ion scan mode, have been typically used to perform such analysis. By means of high-resolution mass spectrometry (HRMS) a much more sensitive and selective detection can be achieved. However, using a single-stage HRMS instrument, there is no unequivocal link to the corresponding precursor ion, since such instrumentation does not permit a previous precursor selection. Thus, to address this limitation, an in silico approach to locate precursor ions, based on diagnostic fragments, was developed. Implemented as an Excel macro, the algorithm rapidly assembles and surveys exact mass data to provide a list of feasible precursor candidates according to the correlation of the chromatographic peak shape profile and other additional filtering criteria (e.g. neutral losses and isotopes). The macro was tested with two families of veterinary drugs, sulfonamides and penicillins, which are known to yield diagnostic product ions when fragmented. Data sets obtained from different food matrices (fish and liver), both at high and low concentration of the target compounds, were investigated in order to evaluate the capabilities and limitations of the reported approach. Finally, other possible applications of this technique, such as the elucidation of elemental compositions based on product ions and corresponding neutral losses, were also presented and discussed.

  19. Correlation of precursor and product ions in single-stage high resolution mass spectrometry. A tool for detecting diagnostic ions and improving the precursor elemental composition elucidation

    International Nuclear Information System (INIS)

    Borràs, S.; Kaufmann, A.; Companyó, R.

    2013-01-01

    Highlights: ► We are describing a technique to spot ions which are derived from each other. ► Single stage high resolution data is used. ► This “in silicon” technique is compared to conventional precursor scan. ► Some applications for this technique are presented. -- Abstract: Monitoring of common diagnostic fragments is essential for recognizing molecules which are members of a particular compound class. Up to now, unit resolving tandem quadrupole mass spectrometers, operating in the precursor ion scan mode, have been typically used to perform such analysis. By means of high-resolution mass spectrometry (HRMS) a much more sensitive and selective detection can be achieved. However, using a single-stage HRMS instrument, there is no unequivocal link to the corresponding precursor ion, since such instrumentation does not permit a previous precursor selection. Thus, to address this limitation, an in silico approach to locate precursor ions, based on diagnostic fragments, was developed. Implemented as an Excel macro, the algorithm rapidly assembles and surveys exact mass data to provide a list of feasible precursor candidates according to the correlation of the chromatographic peak shape profile and other additional filtering criteria (e.g. neutral losses and isotopes). The macro was tested with two families of veterinary drugs, sulfonamides and penicillins, which are known to yield diagnostic product ions when fragmented. Data sets obtained from different food matrices (fish and liver), both at high and low concentration of the target compounds, were investigated in order to evaluate the capabilities and limitations of the reported approach. Finally, other possible applications of this technique, such as the elucidation of elemental compositions based on product ions and corresponding neutral losses, were also presented and discussed

  20. Partial verification bias and incorporation bias affected accuracy estimates of diagnostic studies for biomarkers that were part of an existing composite gold standard.

    Science.gov (United States)

    Karch, Annika; Koch, Armin; Zapf, Antonia; Zerr, Inga; Karch, André

    2016-10-01

    To investigate how choice of gold standard biases estimates of sensitivity and specificity in studies reassessing the diagnostic accuracy of biomarkers that are already part of a lifetime composite gold standard (CGS). We performed a simulation study based on the real-life example of the biomarker "protein 14-3-3" used for diagnosing Creutzfeldt-Jakob disease. Three different types of gold standard were compared: perfect gold standard "autopsy" (available in a small fraction only; prone to partial verification bias), lifetime CGS (including the biomarker under investigation; prone to incorporation bias), and "best available" gold standard (autopsy if available, otherwise CGS). Sensitivity was unbiased when comparing 14-3-3 with autopsy but overestimated when using CGS or "best available" gold standard. Specificity of 14-3-3 was underestimated in scenarios comparing 14-3-3 with autopsy (up to 24%). In contrast, overestimation (up to 20%) was observed for specificity compared with CGS; this could be reduced to 0-10% when using the "best available" gold standard. Choice of gold standard affects considerably estimates of diagnostic accuracy. Using the "best available" gold standard (autopsy where available, otherwise CGS) leads to valid estimates of specificity, whereas sensitivity is estimated best when tested against autopsy alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. When Students Doubt Their Teachers' Diagnostic Competence: Moderation in the Internal/External Frame of Reference Model

    Science.gov (United States)

    Zimmermann, Friederike; Möller, Jens; Köller, Olaf

    2018-01-01

    The internal/external frame of reference model (I/E model) posits that individuals' achievement-related self-concepts are formed through social comparisons (e.g., self vs. peers) within academic domains and dimensional comparisons (e.g., math vs. verbal) between distinct domains. A large body of research has supported the theorized pattern of…

  2. International recommendation for a comprehensive neuropathologic workup of epilepsy surgery brain tissue: A consensus Task Force report from the ILAE Commission on Diagnostic Methods.

    Science.gov (United States)

    Blümcke, Ingmar; Aronica, Eleonora; Miyata, Hajime; Sarnat, Harvey B; Thom, Maria; Roessler, Karl; Rydenhag, Bertil; Jehi, Lara; Krsek, Pavel; Wiebe, Samuel; Spreafico, Roberto

    2016-03-01

    Epilepsy surgery is an effective treatment in many patients with drug-resistant focal epilepsies. An early decision for surgical therapy is facilitated by a magnetic resonance imaging (MRI)-visible brain lesion congruent with the electrophysiologically abnormal brain region. Recent advances in the pathologic diagnosis and classification of epileptogenic brain lesions are helpful for clinical correlation, outcome stratification, and patient management. However, application of international consensus classification systems to common epileptic pathologies (e.g., focal cortical dysplasia [FCD] and hippocampal sclerosis [HS]) necessitates standardized protocols for neuropathologic workup of epilepsy surgery specimens. To this end, the Task Force of Neuropathology from the International League Against Epilepsy (ILAE) Commission on Diagnostic Methods developed a consensus standard operational procedure for tissue inspection, distribution, and processing. The aims are to provide a systematic framework for histopathologic workup, meeting minimal standards and maximizing current and future opportunities for morphofunctional correlations and molecular studies for both clinical care and research. Whenever feasible, anatomically intact surgical specimens are desirable to enable systematic analysis in selective hippocampectomies, temporal lobe resections, and lesional or nonlesional neocortical samples. Correct orientation of sample and the sample's relation to neurophysiologically aberrant sites requires good communication between pathology and neurosurgical teams. Systematic tissue sampling of 5-mm slabs along a defined anatomic axis and application of a limited immunohistochemical panel will ensure a reliable differential diagnosis of main pathologies encountered in epilepsy surgery. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  3. Enhanced Fenton-like removal of nitrobenzene via internal microelectrolysis in nano zerovalent iron/activated carbon composite.

    Science.gov (United States)

    Hu, Sihai; Wu, Yaoguo; Yao, Hairui; Lu, Cong; Zhang, Chengjun

    2016-01-01

    The efficiency of Fenton-like catalysis using nano zerovalent iron (nZVI) is limited by nZVI aggregation and activity loss due to inactive ferric oxide forming on the nZVI surface, which hinders electron transfer. A novel iron-carbon composite catalyst consisting of nZVI and granular activated carbon (GAC), which can undergo internal iron-carbon microelectrolysis spontaneously, was successfully fabricated by the adsorption-reduction method. The catalyst efficiency was evaluated in nitrobenzene (NB) removal via the Fenton-like process (H2O2-nZVI/GAC). The results showed that nZVI/GAC composite was good for dispersing nZVI on the surface of GAC, which permitted much better removal efficiency (93.0%) than nZVI (31.0%) or GAC (20.0%) alone. Moreover, iron leaching decreased from 1.28 to 0.58 mg/L after reaction of 240 min and the oxidation kinetic of the Fenton-like reaction can be described well by the second-order reaction kinetic model (R2=0.988). The composite catalyst showed sustainable catalytic ability and GAC performed as a medium for electron transfer in internal iron-carbon microelectrolysis to promote Fe2+ regeneration and Fe3+/Fe2+ cycles. Therefore, this study represents an important method to design a low cost and high efficiency Fenton-like catalyst in practical application.

  4. Dew point, internal gas pressure, and chemical composition of the gas within the free volume of DWPF canistered waste forms

    International Nuclear Information System (INIS)

    Harbour, J.R.; Herman, D.T.; Crump, S.; Miller, T.J.; McIntosh, J.

    1996-01-01

    The Defense Waste Processing Facility (DWPF) produced 55 canistered waste forms containing simulated waste glass during the four Waste Qualification campaigns of the DWPF Startup Test Program. Testing of the gas within the free volume of these canisters for dew point, internal gas pressure, and chemical composition was performed as part of a continuing effort to demonstrate compliance with the Waste Acceptance Product Specifications. Results are presented for six glass-filled canisters. The dew points within the canisters met the acceptance criterion of < 20 degrees C for all six canisters. Factors influencing the magnitude of the dew point are presented. The chemical composition of the free volume gas was indistinguishable from air for all six canisters. Hence, no foreign materials were present in the gas phase of these canisters. The internal gas pressures within the sealed canisters were < 1 atm at 25 degrees C for all six canisters which readily met the acceptance criterion of an internal gas pressure of less than 1.5 atm at 25 degrees C. These results provided the evidence required to demonstrate compliance with the Waste Acceptance Product Specifications

  5. Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras.

    Science.gov (United States)

    de Paula Silveira, Alessandra C; Chaves, Sacha B; Hilgert, Leandro A; Ribeiro, Ana Paula D

    2017-03-01

    The precision of fit of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) complete crowns is affected by digital impression and restorative material. The purpose of this in vitro study was to evaluate by microcomputed tomography (μCT) the marginal and internal adaptation of composite resin and ceramic complete crowns fabricated with 2 different intraoral cameras and 2 restorative materials. Ten extracted human third molars received crown preparations. For each prepared molar, 2 digital impressions were made with different intraoral cameras of the CEREC system, Bluecam and Omnicam. Four groups were formed: LB (Lava Ultimate+Bluecam), EB (Emax+Bluecam), LO (Lava Ultimate+Omnicam), and EO (Emax+Omnicam). Before measuring the precision of fit, all crowns were stabilized with a silicone material. Each unit (crown + prepared tooth) was imaged with μCT, and marginal and internal discrepancies were analyzed. For the 2D analysis, 120 measurements were made of each crown for marginal adaptation, 20 for marginal discrepancy (MD), and 20 for absolute marginal discrepancy (AMD); and for internal adaptation, 40 for axial space (AS) and 40 for occlusal space (OS). After reconstructing the 3D images, the average internal space (AIS) was calculated by dividing the total volume of the internal space by the contact surface. Data were analyzed with 2-way ANOVA and quantile regression. Regarding marginal adaptation, no significant differences were observed among groups. For internal adaptation measured in the 2D evaluation, a significant difference was observed between LO and EO for the AS variable (Mann-Whitney test; POmnicam, and composite resin crowns showed less discrepancy than did ceramic crowns. The marginal adaptations assessed in all groups showed values within the clinically accepted range. Moreover, the composite resin blocks associated with the Bluecam intraoral camera demonstrated the best results for AIS compared with those of the other groups

  6. Medical Physics Staffing Needs in Diagnostic Imaging and Radionuclide Therapy: An Activity Based Approach [Endorsed by International Organization for Medical Physics

    International Nuclear Information System (INIS)

    2018-01-01

    Over the last decades, the rapid technological development of diagnostic and interventional radiology and nuclear medicine has made them major tools of modern medicine. However, at the same time the involved risks, the growing number of procedures and the increasing complexity of the procedures require competent professional staff to ensure safe and effective patient diagnosis, treatment and management. Medical physicists (or clinically qualified medical physicists) have been recognized as vital health professionals with important and clear responsibilities related to quality and safety of applications of ionizing radiation in medicine. This publication describes an algorithm developed to determine the recommended staffing levels for clinical medical physics services in medical imaging and radionuclide therapy, based on current best practice, as described in international guidelines.

  7. Diagnostic performance of a multiple real-time PCR assay in patients with suspected sepsis hospitalized in an internal medicine ward.

    Science.gov (United States)

    Pasqualini, Leonella; Mencacci, Antonella; Leli, Christian; Montagna, Paolo; Cardaccia, Angela; Cenci, Elio; Montecarlo, Ines; Pirro, Matteo; di Filippo, Francesco; Cistaro, Emma; Schillaci, Giuseppe; Bistoni, Francesco; Mannarino, Elmo

    2012-04-01

    Early identification of causative pathogen in sepsis patients is pivotal to improve clinical outcome. SeptiFast (SF), a commercially available system for molecular diagnosis of sepsis based on PCR, has been mostly used in patients hospitalized in hematology and intensive care units. We evaluated the diagnostic accuracy and clinical usefulness of SF, compared to blood culture (BC), in 391 patients with suspected sepsis, hospitalized in a department of internal medicine. A causative pathogen was identified in 85 patients (22%). Sixty pathogens were detected by SF and 57 by BC. No significant differences were found between the two methods in the rates of pathogen detection (P = 0.74), even after excluding 9 pathogens which were isolated by BC and were not included in the SF master list (P = 0.096). The combination of SF and BC significantly improved the diagnostic yield in comparison to BC alone (P < 0.001). Compared to BC, SF showed a significantly lower contamination rate (0 versus 19 cases; P < 0.001) with a higher specificity for pathogen identification (1.00, 95% confidence interval [CI] of 0.99 to 1.00, versus 0.94, 95% CI of 0.90 to 0.96; P = 0.005) and a higher positive predictive value (1.00, 95% CI of 1.00 to 0.92%, versus 0.75, 95% CI of 0.63 to 0.83; P = 0.005). In the subgroup of patients (n = 191) who had been receiving antibiotic treatment for ≥24 h, SF identified more pathogens (16 versus 6; P = 0.049) compared to BC. These results suggest that, in patients with suspected sepsis, hospitalized in an internal medicine ward, SF could be a highly valuable adjunct to conventional BC, particularly in patients under antibiotic treatment.

  8. Effect of Material Parameters on Steady State Creep in a Thick Composite Cylinder Subjected to Internal Pressure

    Directory of Open Access Journals (Sweden)

    Tejeet Singh

    2009-12-01

    Full Text Available The steady state creep in Al- SiCP composite cylinder subjected to internal pressure was investigated. The creep behavior of the material were described by threshold stress based creep law by assuming a stress exponent of 5. The effect of size and content of the reinforcement (SiCP , and operating temperature on the stresses and strain rates in the composite cylinder were investigated. The stresses in the cylinder did not have significant variation with varying size and content of the reinforcement, and operating temperature. However, the tangential as well as radial strain rates in the cylinder could be reduced to a significant extent by decreasing size of SiCP, increasing the content of SiCP and decreasing operating temperature.

  9. Internal and external factors affecting photosynthetic pigment composition in plants: a meta-analytical approach.

    Science.gov (United States)

    Esteban, Raquel; Barrutia, Oihana; Artetxe, Unai; Fernández-Marín, Beatriz; Hernández, Antonio; García-Plazaola, José Ignacio

    2015-04-01

    Photosynthetic pigment composition has been a major study target in plant ecophysiology during the last three decades. Although more than 2000 papers have been published, a comprehensive evaluation of the responses of photosynthetic pigment composition to environmental conditions is not yet available. After an extensive survey, we compiled data from 525 papers including 809 species (subkingdom Viridiplantae) in which pigment composition was described. A meta-analysis was then conducted to assess the ranges of photosynthetic pigment content. Calculated frequency distributions of pigments were compared with those expected from the theoretical pigment composition. Responses to environmental factors were also analysed. The results revealed that lutein and xanthophyll cycle pigments (VAZ) were highly responsive to the environment, emphasizing the high phenotypic plasticity of VAZ, whereas neoxanthin was very stable. The present meta-analysis supports the existence of relatively narrow limits for pigment ratios and also supports the presence of a pool of free 'unbound' VAZ. Results from this study provide highly reliable ranges of photosynthetic pigment contents as a framework for future research on plant pigments. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  10. Evaluation of conjugate, radial heat transfer in an internally insulated composite pipe

    NARCIS (Netherlands)

    Reurings, C.; Koussios, S.; Bergsma, O.K.; Vergote, K.

    2015-01-01

    In order to compete with steel, a fibre-reinforced composite exhaust wall with a general-purpose resin system requires an effective but lightweight insulation layer. However a lack of experimental methods for heat transfer from turbulent gas flow to pipe walls lined with a porous insulation layer

  11. The ICRU (International Commission on Radiation Units and Measurements): Its contribution to dosimetry in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Wambersie, A.; Zoetelief, J.; Menzel, H. G.; Paretzke, H.

    2005-01-01

    The ICRU (International Commission on Radiation Units and Measurements was created to develop a coherent system of quantities and units, universally accepted in all fields where ionizing radiation is used. Although the accuracy of dose or kerma may be low for most radiological applications, the quantity which is measured must be clearly specified. Radiological dosimetry instruments are generally calibrated free-in-air in terms of air kerma. However, to estimate the probability of harm at low dose, the mean absorbed dose for organs is used. In contrast, at high doses, the likelihood of harm is related to the absorbed dose at the site receiving the highest dose. Therefore, to assess the risk of deterministic and stochastic effects, a detailed knowledge of absorbed dose distribution, organ doses, patient age and gender is required. For interventional radiology, where the avoidance of deterministic effects becomes important, dose conversion coefficients are generally not yet developed. (authors)

  12. Application of a high-repetition-rate laser diagnostic system for single-cycle-resolved imaging in internal combustion engines.

    Science.gov (United States)

    Hult, Johan; Richter, Mattias; Nygren, Jenny; Aldén, Marcus; Hultqvist, Anders; Christensen, Magnus; Johansson, Bengt

    2002-08-20

    High-repetition-rate laser-induced fluorescence measurements of fuel and OH concentrations in internal combustion engines are demonstrated. Series of as many as eight fluorescence images, with a temporal resolution ranging from 10 micros to 1 ms, are acquired within one engine cycle. A multiple-laser system in combination with a multiple-CCD camera is used for cycle-resolved imaging in spark-ignition, direct-injection stratified-charge, and homogeneous-charge compression-ignition engines. The recorded data reveal unique information on cycle-to-cycle variations in fuel transport and combustion. Moreover, the imaging system in combination with a scanning mirror is used to perform instantaneous three-dimensional fuel-concentration measurements.

  13. Influence of electron irradiation on internal friction and structure evolution of polymer composites

    International Nuclear Information System (INIS)

    Ismailova, G.A.

    2007-01-01

    Full text: Important qualitative information on structural evolution and radiation alterations in polymer materials under the action of ionizing radiation can be obtained from the analysis of the temperature dependences of internal friction. Changing of internal friction parameters of relax maxima during irradiation is qualitative degree parameter of radiation scission-cross linking of the polymer molecules. In this work, the general phenomenological approach is realized by introduction of the effective 'observed' parameters into the simple kinetic equations. The applicability of such approach is justified by the fact that kinetics of both internal friction and scission-cross linking processes can be characterized by the same effective parameters. Temperature dependences of internal friction are experimentally studied in epoxy irradiated by 2.5 MeV pulse electron beam to different doses (D=3 MGy, 6 MGy and 9 MGy). Time dependences of internal friction characteristics associated with radiation-induced processes of polymer scission and cross-linking are analyzed and discussed. Experimental data on kinetics of structural transformations in epoxy are interpreted on the base of analytical solutions of differential equations for free radical accumulation during and after irradiation subject to the arbitrary effective order of radical recombination. It is shown that in the range of doses and dose rates under study radiation-induced scission predominates during polymer irradiation but in a certain period of time after irradiation scission changes to cross-linking. Characteristics of the kinetic curves obtained essentially depend on the dose

  14. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: early results.

    Science.gov (United States)

    Hwang, Ho Young; Kim, Jun Sung; Oh, Se Jin; Kim, Ki-Bong

    2012-11-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft trial was designed to evaluate the saphenous vein compared with the right internal thoracic artery as a Y-composite graft anastomosed to the side of the left internal thoracic artery. In this early analysis, we compared early angiographic patency rates and clinical outcomes. From September 2008 to October 2011, 224 patients with multivessel coronary artery disease were randomized prospectively to undergo off-pump revascularization using the saphenous vein group (n = 112) or the right internal thoracic artery group (n = 112) as Y-composite grafts. Early postoperative (1.4 ± 1.1 days) angiographic patency and clinical outcomes were compared. There was 1 operative death in the right internal thoracic artery group. No statistically significant differences in postoperative morbidities, including atrial fibrillation and acute renal failure, were observed between the groups. The number of distal anastomoses using the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 2.3 ± 0.8 and 1.9 ± 0.7 in the saphenous vein and right internal thoracic artery groups, respectively (P < .001). A third conduit was used in 44 patients (saphenous vein group vs right internal thoracic artery group, 4/109 vs 40/110; P < .001) to extend the side-arm Y-composite graft for complete revascularization. Early angiography demonstrated an overall patency rate of 99.4% (771 of 776 distal anastomoses). Patency rates of the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 98.8% (245 of 248) and 99.5% (207 of 208) in the saphenous vein and right internal thoracic artery groups, respectively (P = .629). A third conduit was needed to extend the right internal thoracic artery composite graft and reach the target vessels in 36.4% (40/110) of the patients. The saphenous vein composite graft was comparable with the right internal thoracic artery composite graft

  15. Proceedings Second International Conference on Composite Science and Technology 9 - 11 June 1998 Durban South Africa

    Science.gov (United States)

    1998-06-01

    LARRODE E., CASAMAYOR M.J. .Design and Manufacturing of 3-D continuous composite structures. CONGRESO INTERNACIONAL DE MATERIALES COMPUESTOS (ICCM VIII...construction" Robert J. Scott. [4] "Los materiales compuestos de fibra de vidrio" P. Antequera, L. Jim6nez, A. Miravete. [5] "Hull structural design...34Absorci6n de energfa en vehfculos mediante materiales compuestos de matriz orginica". Actas del I Congreso Nacional de Materiales Compuestos - Sevilla

  16. International collaborative project to compare and track the nutritional composition of fast foods

    Directory of Open Access Journals (Sweden)

    2012-07-01

    Full Text Available Abstract Background Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Methods/design Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. Discussion This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  17. International collaborative project to compare and track the nutritional composition of fast foods.

    Science.gov (United States)

    2012-07-27

    Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.

  18. SEM Evaluation of Internal Adaptation of Bases and Liners under Composite Restorations

    Directory of Open Access Journals (Sweden)

    Dimitrios Dionysopoulos

    2014-04-01

    Full Text Available The aim of this study was to evaluate the interfacial microgaps generating between different materials and between materials and dentin after polymerization of the composite restorations, using SEM. Methods: The materials investigated were a composite, an adhesive, a RMGI, and a calcium hydroxide. Thirty third molars were selected and two circular class V cavities (5 mm × 3 mm for each tooth were made. The teeth were randomly assigned into six groups and restored with a combination of the materials. The specimens were subjected to thermocycling and each tooth was sectioned mesiodistally in two halves. Each half was sectioned along the longitudinal axis through the center of the restorations to obtain a slice of 2 mm. The specimens were examined under SEM. The interfaces between the liners, the liners and dentin, and between the liners and the composite were examined for microgaps. Results: The results showed that there was not any significant difference in the mean width of microgaps in the interfaces between Dycal-dentin and Vitrebond-dentin (p>0.05. However, the width of microgaps in the interfaces between dentin-Clearfil Tri-S Bond was significantly smaller (p<0.05. The use of Clearfil Tri-S Bond reduced the possibility of microgap formation between the bonded interface and the materials tested.

  19. VOLUMES OF GENERA AND SPECIES COMPOSITION OF ORIBATIDA (ACARIFORMES, ORIBATIDA OF THE INTERNAL MOUNTAIN DAGESTAN

    Directory of Open Access Journals (Sweden)

    G. M. Abdurakhmanov

    2013-01-01

    Full Text Available This work is based on research and materials collected from 2000 to 2012, with the application of the method of selection of soil samples, according to the methodology of the quantitative survey. As a result of the conducted researches on the territory of the internal mountain Dagestan found 190 species of Oribatida belonging to 83 generations.

  20. Diagnostic accuracy of phosphor plate systems and conventional radiography in the detection of simulated internal root resorption.

    Science.gov (United States)

    Vasconcelos, Karla de Faria; Rovaris, Karla; Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Távora, Débora de Melo; Bóscolo, Frab Norberto

    2017-11-01

    To evaluate the performance of conventional radiography and photostimulable phosphor (PSP) plate in the detection of simulated internal root resorption (IRR) lesions in early stages. Twenty single-rooted teeth were X-rayed before and after having a simulated IRR early lesion. Three imaging systems were used: Kodak InSight dental film and two PSPs digital systems, Digora Optime and VistaScan. The digital images were displayed on a 20.1″ LCD monitor using the native software of each system, and the conventional radiographs were evaluated on a masked light box. Two radiologists were asked to indicate the presence or absence of IRR and, after two weeks, all images were re-evaluated. Cohen's kappa coefficient was calculated to assess intra- and interobserver agreement. The three imaging systems were compared using the Kruskal-Wallis test. For interexaminer agreement, overall kappa values were 0.70, 0.65 and 0.70 for conventional film, Digora Optima and VistaScan, respectively. Both the conventional and digital radiography presented low sensitivity, specificity, accuracy, positive and negative predictive values with no significant difference between imaging systems (p = .0725). The performance of conventional and PSP was similar in the detection of simulated IRR lesions in early stages with low accuracy.

  1. Investigation of the design of a metal-lined fully wrapped composite vessel under high internal pressure

    Science.gov (United States)

    Kalaycıoğlu, Barış; Husnu Dirikolu, M.

    2010-09-01

    In this study, a Type III composite pressure vessel (ISO 11439:2000) loaded with high internal pressure is investigated in terms of the effect of the orientation of the element coordinate system while simulating the continuous variation of the fibre angle, the effect of symmetric and non-symmetric composite wall stacking sequences, and lastly, a stacking sequence evaluation for reducing the cylindrical section-end cap transition region stress concentration. The research was performed using an Ansys® model with 2.9 l volume, 6061 T6 aluminium liner/Kevlar® 49-Epoxy vessel material, and a service internal pressure loading of 22 MPa. The results show that symmetric stacking sequences give higher burst pressures by up to 15%. Stacking sequence evaluations provided a further 7% pressure-carrying capacity as well as reduced stress concentration in the transition region. Finally, the Type III vessel under consideration provides a 45% lighter construction as compared with an all metal (Type I) vessel.

  2. A multiscale MD-FE model of diffusion in composite media with internal surface interaction based on numerical homogenization procedure.

    Science.gov (United States)

    Kojic, M; Milosevic, M; Kojic, N; Kim, K; Ferrari, M; Ziemys, A

    2014-02-01

    Mass transport by diffusion within composite materials may depend not only on internal microstructural geometry, but also on the chemical interactions between the transported substance and the material of the microstructure. Retrospectively, there is a gap in methods and theory to connect material microstructure properties with macroscale continuum diffusion characteristics. Here we present a new hierarchical multiscale model for diffusion within composite materials that couples material microstructural geometry and interactions between diffusing particles and the material matrix. This model, which bridges molecular dynamics (MD) and the finite element (FE) method, is employed to construct a continuum diffusion model based on a novel numerical homogenization procedure. The procedure is general and robust for evaluating constitutive material parameters of the continuum model. These parameters include the traditional bulk diffusion coefficients and, additionally, the distances from the solid surface accounting for surface interaction effects. We implemented our models to glucose diffusion through the following two geometrical/material configurations: tightly packed silica nanospheres, and a complex fibrous structure surrounding nanospheres. Then, rhodamine 6G diffusion analysis through an aga-rose gel network was performed, followed by a model validation using our experimental results. The microstructural model, numerical homogenization and continuum model offer a new platform for modeling and predicting mass diffusion through complex biological environment and within composite materials that are used in a wide range of applications, like drug delivery and nanoporous catalysts.

  3. A multiscale MD–FE model of diffusion in composite media with internal surface interaction based on numerical homogenization procedure

    Science.gov (United States)

    Kojic, M.; Milosevic, M.; Kojic, N.; Kim, K.; Ferrari, M.; Ziemys, A.

    2014-01-01

    Mass transport by diffusion within composite materials may depend not only on internal microstructural geometry, but also on the chemical interactions between the transported substance and the material of the microstructure. Retrospectively, there is a gap in methods and theory to connect material microstructure properties with macroscale continuum diffusion characteristics. Here we present a new hierarchical multiscale model for diffusion within composite materials that couples material microstructural geometry and interactions between diffusing particles and the material matrix. This model, which bridges molecular dynamics (MD) and the finite element (FE) method, is employed to construct a continuum diffusion model based on a novel numerical homogenization procedure. The procedure is general and robust for evaluating constitutive material parameters of the continuum model. These parameters include the traditional bulk diffusion coefficients and, additionally, the distances from the solid surface accounting for surface interaction effects. We implemented our models to glucose diffusion through the following two geometrical/material configurations: tightly packed silica nanospheres, and a complex fibrous structure surrounding nanospheres. Then, rhodamine 6G diffusion analysis through an aga-rose gel network was performed, followed by a model validation using our experimental results. The microstructural model, numerical homogenization and continuum model offer a new platform for modeling and predicting mass diffusion through complex biological environment and within composite materials that are used in a wide range of applications, like drug delivery and nanoporous catalysts. PMID:24578582

  4. Comparison of diet consumption, body composition and lipoprotein lipid values of Kuwaiti fencing players with international norms

    Directory of Open Access Journals (Sweden)

    Hajji Salman

    2011-10-01

    Full Text Available Abstract Background No published data is currently available that describes the dietary patterns or physiological profiles of athletes participating on the Kuwaiti national fencing team and its potential impact on health and physical performance. The purpose of this investigation was to: 1 collect baseline data on nutrient intake 2 collect, analyze and report baseline for body composition, plasma lipid and lipoprotein concentrations during the competitive season, 3 compare the results with the international norms, 4 and provide necessary health and nutritional information in order to enhance the athletes' performance and skills. Methods Fifteen national-class fencers 21.5 ± 2.6 years of age participated in this study. Food intake was measured using a 3-day food record. Body composition was estimated using both the BOD POD and Body Mass Index (BMI. Total blood lipid profiles and maximum oxygen consumption was measured for each of the subjects during the competitive season. Results The results of the present study showed significant differences in dietary consumption in comparison with the recommended dietary allowances (RDA. The blood lipids profile and body composition (BMI and % body fat were in normal range in comparison with international norms However, the average VO2 max value was less than the value of the other fencers. Conclusion Due to the results of the research study, a dietary regimen can be designed that would better enhance athletic performance and minimize any health risks associated with nutrition. Percent body fat and BMI will also be categorized for all players. In addition, the plasma blood tests will help to determine if any of the players have an excessive level of lipids or any blood abnormalities. The outcomes of present study will have a direct impact on the players health and therefore their skills and athletic performance.

  5. Dip-Test Internal Stress and the Composite Model of Creep Deformation

    Czech Academy of Sciences Publication Activity Database

    Dobeš, Ferdinand; Orlová, Alena

    2005-01-01

    Roč. 482, - (2005), s. 291-294 ISSN 0255-5476. [Materials Structure & Micromechanics of Fracture /4./. Brno, 23.06.2004-25.06.2004] R&D Pro jects: GA AV ČR(CZ) IAA2041202 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * internal stress * subgrain Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.399, year: 2005

  6. Substance use disorders: Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10).

    Science.gov (United States)

    Hasin, Deborah; Hatzenbuehler, Mark L; Keyes, Katherine; Ogburn, Elizabeth

    2006-09-01

    Two major nomenclatures, Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10), currently define substance use disorders for broad audiences of users with different training, experience and interests. A comparison of these definitions and their implications for DSM-V and ICD-11 has not been available. The background for the dependence concept and abuse, harmful use, withdrawal, substance-induced disorders and remission and other substance-related conditions is reviewed. Reliability evidence is presented, as is validity evidence from approaches including psychometric, genetic and animal studies. The relevance of the DSM-IV and ICD-10 compared to alternative systems (e.g. the Addiction Severity Index) is considered. Reliability and psychometric validity evidence for substance dependence is consistently strong, but more mixed for abuse and harmful use. Findings on the genetics of alcohol disorders support the validity of the dependence concept, while animal studies underscore the centrality of continued use despite negative consequences to the concept of dependence. While few studies on substance-induced disorders have been conducted, those published show good reliability and validity when elements of DSM-IV and ICD-10 are combined. Dependence in DSM-V and ICD-11 should be retained, standardizing both criteria sets and adding a severity measure. The consequences of heavy use should be measured independently of dependence; add cannabis withdrawal if further research supports existing evidence; conduct further studies of the substance-induced psychiatric categories; standardize their criteria across DSM-V and ICD-11; develop a theoretical basis for better remission criteria; consider changing substance 'abuse' to substance 'dysfunction disorder'; and conduct clinician education on the value of the diagnostic criteria.

  7. High energy flux thermo-mechanical test of 1D-carbon-carbon fibre composite prototypes for the SPIDER diagnostic calorimeter

    International Nuclear Information System (INIS)

    De Muri, M.; Pasqualotto, R.; Dalla Palma, M.; Cervaro, V.; Fasolo, D.; Franchin, L.; Tollin, M.; Serianni, G.; Cavallin, T.; Greuner, H.; Böswirth, B.

    2014-01-01

    Operation of the thermonuclear fusion experiment ITER requires additional heating via injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction in Padova, the production of negative ions will be studied and optimised. STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic used to characterise the SPIDER beam during short pulse operation (several seconds) to verify if the beam meets the ITER requirements about the maximum allowed beam non-uniformity (below ±10%). The major components of STRIKE are 16 1D-CFC (Carbon-Carbon Fibre Composite) tiles, observed at the rear side by a thermal camera. This contribution gives an overview of some tests under high energy particle flux, aimed at verifying the thermo-mechanical behaviour of several CFC prototype tiles. The tests were performed in the GLADIS facility at IPP (Max-Plank-Institut für Plasmaphysik), Garching. Dedicated linear and nonlinear simulations were carried out to interpret the experiments and a comparison of the experimental data with the simulation results is presented. The results of some morphological and structural studies on the material after exposure to the GLADIS beam are also given

  8. Preface: 2nd International Conference on Structural Nano Composites (NANOSTRUC2014)

    International Nuclear Information System (INIS)

    Njuguna, J; Verdejo, R

    2014-01-01

    The NANOSTRUC 2014 took place at CSIC, Madrid, Spain. The conference theme on 'Nanosciences and Nanotechnologies – Recent Advances towards Nanoproducts and Applications'. The conference aimed to promote activities in various areas of materials and structures by providing a forum for exchange of ideas, presentation of technical achievements and discussion of future directions. NANOSTRUC conferences brings together an international community of experts to discuss the state-of-the-art, new research results, perspectives of future developments, and innovative applications relevant to structural materials, engineering structures, nanocomposites, modelling and simulations, and their related application areas

  9. Internal strain evolution during heating of Ti-6Al-4V/SCS-6 composite

    International Nuclear Information System (INIS)

    Choo, H.; Rangaswamy, P.; Bourke, M.A.M.

    1999-01-01

    The characteristics of the residual stresses and their effects on the properties in continuous SiC fiber reinforced Ti-6Al-4V matrix composites (TMCs) have been extensively studied. However, to date, few experimental studies (e.g. Ti-14Al-21Nb/SCS-6) have characterized the thermal residual strain in TMCs at elevated temperatures. Therefore, the authors investigated the evolution of the thermal residual strain during heating of Ti-6Al-4V/35vol% SiC composite. In this study the authors used in situ high temperature neutron diffraction to measure strains: (1) in the matrix (α and β phases) and in the fiber, (2) for several lattice reflections in each phase and (3) from both axial and the transverse directions. One distinguishing feature is the wide temperature range (from room temperature up to 1,170K) over which the study was performed. Although the proposed application temperature is typically less than 800K, TMCs are subject to higher temperatures during fabrication and may experience high temperature excursions while in service. Therefore, the authors extended the study to the high temperature regime where the matrix starts to undergo a phase transformation between αminus and βminusTi. Measurements from this regime (800approximately1,170K) provide insights on; (1) the inelastic relaxation of the residual strains through matrix yielding and creep, (2) the effect of the phase transformation on the residual strains and (3) the effect of the presence of SiC on the matrix phase evolution

  10. Development of composite indicator of Ukraine’s international reserves adequacy

    Directory of Open Access Journals (Sweden)

    Mykhaylo Makarenko

    2015-11-01

    Full Text Available This paper develops an indicator for estimating international reserves adequacy in Ukraine taking into account its unique characteristics. The proposed indicator was constructed based on the modification of IMF adequacy metric by changing weighting coefficients of potential balance of payments vulnerabilities based on historical data for Ukraine and by the inclusion of import as an additional component. In comparison to the IMF metric our indicator implies greater international reserves. This is due to the fact that balance of payments of Ukraine is very sensitive to current account shocks such as worsening terms of trade so our indicator except import component has increased weighting coefficient of export earnings. Also, compared to the IMF metrics our indicator provides more weighting coefficients of the other portfolio liabilities and the money supply that represents the sensitivity to financial account shocks. Reduced weighting coefficient of the short-term debt could be explained by the partial refinancing of external debt. This new indicator suggests that the accumulated levels of reserves of Ukraine have been inadequate at 1 April 2015.

  11. Design Development of a Combined Deployment and Pointing System for the International Space Station Neutron Star Interior Composition Explorer Telescope

    Science.gov (United States)

    Budinoff, Jason; Gendreau, Keith; Arzoumanian, Zaven; Baker, Charles; Berning, Robert; Colangelo, TOdd; Holzinger, John; Lewis, Jesse; Liu, Alice; Mitchell, Alissa; hide

    2016-01-01

    This paper describes the design of a unique suite of mechanisms that make up the Deployment and Pointing System (DAPS) for the Neutron Star Interior Composition Explorer (NICER/SEXTANT) instrument, an X-Ray telescope, which will be mounted on the International Space Station (ISS). The DAPS system uses four stepper motor actuators to deploy the telescope box, latch it in the deployed position, and allow it to track sky targets. The DAPS gimbal architecture provides full-hemisphere coverage, and is fully re-stowable. The compact design of the mechanism allowed the majority of total instrument volume to be used for science. Override features allow DAPS to be stowed by ISS robotics.

  12. Research of plating aluminum and aluminum foil on internal surface of carbon fiber composite material centrifuge rotor drum

    International Nuclear Information System (INIS)

    Lu Xiuqi; Dong Jinping; Dai Xingjian

    2014-01-01

    In order to improve the corrosion resistance, thermal conductivity and sealability of the internal surface of carbon fiber/epoxy composite material centrifuge rotor drum, magnetron sputtering aluminum and pasting an aluminum foil on the inner wall of the drum are adopted to realize the aim. By means of XRD, SEM/EDS and OM, the surface topography of aluminum coated (thickness of 5 μm and 12 μm) and aluminum foil (12 μm) are observed and analyzed; the cohesion of between aluminum coated (or aluminum foil) and substrate material (CFRP) is measured by scratching experiment, direct drawing experiment, and shear test. Besides, the ultra-high-speed rotation experiment of CFRP ring is carried out to analyze stress and strain of coated aluminum (or aluminum foil) which is adhered on the ring. The results showed aluminum foil pasted on inner surface do better performance than magnetron sputtering aluminum on CFRP centrifuge rotor drum. (authors)

  13. Unification of space-time and internal symmetries through superstrings, with elementary or composite quarks

    International Nuclear Information System (INIS)

    Huebsch, T.

    1987-01-01

    Symmetry properties of a given physical system constrain greatly the theoretical models built in the attempt to describe the system. In complement, the symmetry properties of a system typically undergo dramatic changes during its evolution in time, underpinning the concept of phase transitions. Employing these two ideas we analyze models of Particle Physics at increasingly higher levels of unification, attempting to cover the wide span from the domain of experimentally accessible energies to scales where all the known interactions (including gravity) may be described as low-energy effects of the tremendous and intricate structure of Superstring theories. In particular, we study the scenario of compactification of the Heterotic Superstring theory involving Calabi-Yau manifolds and derive the basic properties of the effective point-field theory action, give a huge class of constructions and devise some techniques for future analysis. Further we study the possibility that the phase-transition from Superstrings to observed particles involves an intermediary phase where the observed particles exhibit compositeness, together with some consequences on the low-energy phenomenology. Finally we include our attempt to modify the SU(5) model, as one of the simplest Grand-unified models, to provide a solution to its difficulties. As we now show, the problems we were trying to address are so generic that some of them remain (in a disguised form) even at the present understanding of the Superstring theories, the most ample constructs of fundamental Physics so far

  14. Internal iron biomineralization in Imperata cylindrica, a perennial grass: chemical composition, speciation and plant localization.

    Science.gov (United States)

    Rodríguez, N; Menéndez, N; Tornero, J; Amils, R; de la Fuente, V

    2005-03-01

    * The analysis of metal distribution in Imperata cylindrica, a perennial grass isolated from the banks of Tinto River (Iberian Pyritic Belt), an extreme acidic environment with high content in metals, has shown a remarkable accumulation of iron. This property has been used to study iron speciation and its distribution among different tissues and structures of the plant. * Mossbauer (MS) and X-ray diffraction (XRD) were used to determine the iron species, scanning electron microscopy (SEM) to locate iron biominerals among plant tissue structures, and energy-dispersive X-ray microanalysis (EDAX), X-ray fluorescence (TXRF) and inductively coupled plasma emission spectroscopy (ICP-MS) to confirm their elemental composition. * The MS spectral analysis indicated that iron accumulated in this plant mainly as jarosite and ferritin. The presence of jarosite was confirmed by XRD and the distribution of both minerals in structures of different tissues was ascertained by SEM-EDAX analysis. * The convergent results obtained by complementary techniques suggest a complex iron management system in I. cylindrica, probably as a consequence of the environmental conditions of its habitat.

  15. Grain boundaries of nanocrystalline materials - their widths, compositions, and internal structures

    International Nuclear Information System (INIS)

    Fultz, B.; Frase, H.N.

    2000-01-01

    Nanocrystalline materials contain many atoms at and near grain boundaries. Sufficient numbers of Moessbauer probe atoms can be situated in grain boundary environments to make a clear contribution to the measured Moessbauer spectrum. Three types of measurements on nanocrystalline materials are reported here, all using Moessbauer spectrometry in conjunction with X-ray diffractometry, transmission electron microscopy, or small angle neutron scattering. By measuring the fraction of atoms contributing to the grain boundary component in a Moessbauer spectrum, and by knowing the grain size of the material, it is possible to deduce the average width of grain boundaries in metallic alloys. It is found that these widths are approximately 0.5 nm for fcc alloys and slightly larger than 1.0 nm for bcc alloys.Chemical segregation to grain boundaries can be measured by Moessbauer spectrometry, especially in conjunction with small angle neutron scattering. Such measurements on Fe-Cu and Fe 3 Si-Nb were used to study how nanocrystalline materials could be stabilized against grain growth by the segregation of Cu and Nb to grain boundaries. The segregation of Cu to grain boundaries did not stabilize the Fe-Cu alloys against grain growth, since the grain boundaries were found to widen and accept more Cu atoms during annealing. The Nb additions to Fe 3 Si did suppress grain growth, perhaps because of the low mobility of Nb atoms, but also perhaps because Nb atoms altered the chemical ordering in the alloy.The internal structure of grain boundaries in nanocrystalline materials prepared by high-energy ball milling is found to be unstable against internal relaxations at low temperatures. The Moessbauer spectra of the nanocrystalline samples showed changes in the hyperfine fields attributable to movements of grain boundary atoms. In conjunction with SANS measurements, the changes in grain boundary structure induced by cryogenic exposure and annealing at low temperature were found to be

  16. A diagnostic imaging approach for online characterization of multi-impact in aircraft composite structures based on a scanning spatial-wavenumber filter of guided wave

    Science.gov (United States)

    Ren, Yuanqiang; Qiu, Lei; Yuan, Shenfang; Su, Zhongqing

    2017-06-01

    Monitoring of impact and multi-impact in particular in aircraft composite structures has been an intensive research topic in the field of guided-wave-based structural health monitoring (SHM). Compared with the majority of existing methods such as those using signal features in the time-, frequency- or joint time-frequency domain, the approach based on spatial-wavenumber filter of guided wave shows superb advantage in effectively distinguishing particular wave modes and identifying their propagation direction relative to the sensor array. However, there exist two major issues when conducting online characterization of multi-impact event. Firstly, the spatial-wavenumber filter should be realized in the situation that the wavenumber of high spatial resolution of the complicated multi-impact signal cannot be measured or modeled. Secondly, it's difficult to identify the multiple impacts and realize multi-impact localization due to the overlapping of wavenumbers. To address these issues, a scanning spatial-wavenumber filter based diagnostic imaging method for online characterization of multi-impact event is proposed to conduct multi-impact imaging and localization in this paper. The principle of the scanning filter for multi-impact is developed first to conduct spatial-wavenumber filtering and to achieve wavenumber-time imaging of the multiple impacts. Then, a feature identification method of multi-impact based on eigenvalue decomposition and wavenumber searching is presented to estimate the number of impacts and calculate the wavenumber of the multi-impact signal, and an image mapping method is proposed as well to convert the wavenumber-time image to an angle-distance image to distinguish and locate the multiple impacts. A series of multi-impact events are applied to a carbon fiber laminate plate to validate the proposed methods. The validation results show that the localization of the multiple impacts are well achieved.

  17. Effects of changes in nutrient loading and composition on hypoxia dynamics and internal nutrient cycling of a stratified coastal lagoon

    Science.gov (United States)

    Zhu, Yafei; McCowan, Andrew; Cook, Perran L. M.

    2017-10-01

    The effects of changes in catchment nutrient loading and composition on the phytoplankton dynamics, development of hypoxia and internal nutrient dynamics in a stratified coastal lagoon system (the Gippsland Lakes) were investigated using a 3-D coupled hydrodynamic biogeochemical water quality model. The study showed that primary production was equally sensitive to changed dissolved inorganic and particulate organic nitrogen loads, highlighting the need for a better understanding of particulate organic matter bioavailability. Stratification and sediment carbon enrichment were the main drivers for the hypoxia and subsequent sediment phosphorus release in Lake King. High primary production stimulated by large nitrogen loading brought on by a winter flood contributed almost all the sediment carbon deposition (as opposed to catchment loads), which was ultimately responsible for summer bottom-water hypoxia. Interestingly, internal recycling of phosphorus was more sensitive to changed nitrogen loads than total phosphorus loads, highlighting the potential importance of nitrogen loads exerting a control over systems that become phosphorus limited (such as during summer nitrogen-fixing blooms of cyanobacteria). Therefore, the current study highlighted the need to reduce both total nitrogen and total phosphorus for water quality improvement in estuarine systems.

  18. Effects of changes in nutrient loading and composition on hypoxia dynamics and internal nutrient cycling of a stratified coastal lagoon

    Directory of Open Access Journals (Sweden)

    Y. Zhu

    2017-10-01

    Full Text Available The effects of changes in catchment nutrient loading and composition on the phytoplankton dynamics, development of hypoxia and internal nutrient dynamics in a stratified coastal lagoon system (the Gippsland Lakes were investigated using a 3-D coupled hydrodynamic biogeochemical water quality model. The study showed that primary production was equally sensitive to changed dissolved inorganic and particulate organic nitrogen loads, highlighting the need for a better understanding of particulate organic matter bioavailability. Stratification and sediment carbon enrichment were the main drivers for the hypoxia and subsequent sediment phosphorus release in Lake King. High primary production stimulated by large nitrogen loading brought on by a winter flood contributed almost all the sediment carbon deposition (as opposed to catchment loads, which was ultimately responsible for summer bottom-water hypoxia. Interestingly, internal recycling of phosphorus was more sensitive to changed nitrogen loads than total phosphorus loads, highlighting the potential importance of nitrogen loads exerting a control over systems that become phosphorus limited (such as during summer nitrogen-fixing blooms of cyanobacteria. Therefore, the current study highlighted the need to reduce both total nitrogen and total phosphorus for water quality improvement in estuarine systems.

  19. Report of International Workshop on tracing isotopic composition of past and present precipitation - opportunities for climate and water studies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The Workshop on Tracing Isotopic Composition of Past and Present Precipitation - Opportunities for Climate and Water Studies, was jointly organized by the World Meteorological Organization (WMO), the International Atomic Energy Agency (IAEA), Past Global Changes (PAGES) - a core project of the International Geosphere - Biosphere Programme (IGBP), and the International Association of Hydrological Sciences (IAHS). The Global Network ``Isotopes in Precipitation`` (GNIP) was initiated by IAEA in 1958 and became operational in 1961. The main objective was to collect systematic data on isotopic content of precipitation on a global scale and to establish temporal and spatial variations of environmental isotopes in precipitation. The network is now expected to serve additional purposes, namely as a benchmark for the interpretation of paleo-records, as a validation tool for Global Circulation Models, and for establishing large-scale regional (and continental-scale) waster balances. Furthermore, the structure of GNIP should be strengthened. This includes the build-up of: stations located close to major natural climatic archives (e.g. Greenland, mountain areas); stations which represent climatically sensitive areas (indicated by GCM`s and biome models). Isotope monitoring of river outflow from major continental basins should be initiated. This could be realized in co-operation with the UNEP/WHO Global Environmental Monitoring System-Water (GEMS-Water). The deuterium excess parameter ({delta}) is of particular importance in climate modelling and in the understanding of hydro-meteorological pathways. The use of the deuterium excess imposes strict requirements on the accuracy of deuterium and oxygen-18 analysis. A GNIP-based worldwide documentation of quality control regarding sampling, shipping and measurements is needed. The IAEA/WMO database and other isotope data sets should be included in the World Data Center A for palaeo-climatology. Refs, figs, tabs.

  20. Report of International Workshop on tracing isotopic composition of past and present precipitation - opportunities for climate and water studies

    International Nuclear Information System (INIS)

    1995-01-01

    The Workshop on Tracing Isotopic Composition of Past and Present Precipitation - Opportunities for Climate and Water Studies, was jointly organized by the World Meteorological Organization (WMO), the International Atomic Energy Agency (IAEA), Past Global Changes (PAGES) - a core project of the International Geosphere - Biosphere Programme (IGBP), and the International Association of Hydrological Sciences (IAHS). The Global Network ''Isotopes in Precipitation'' (GNIP) was initiated by IAEA in 1958 and became operational in 1961. The main objective was to collect systematic data on isotopic content of precipitation on a global scale and to establish temporal and spatial variations of environmental isotopes in precipitation. The network is now expected to serve additional purposes, namely as a benchmark for the interpretation of paleo-records, as a validation tool for Global Circulation Models, and for establishing large-scale regional (and continental-scale) waster balances. Furthermore, the structure of GNIP should be strengthened. This includes the build-up of: stations located close to major natural climatic archives (e.g. Greenland, mountain areas); stations which represent climatically sensitive areas (indicated by GCM's and biome models). Isotope monitoring of river outflow from major continental basins should be initiated. This could be realized in co-operation with the UNEP/WHO Global Environmental Monitoring System-Water (GEMS-Water). The deuterium excess parameter (δ) is of particular importance in climate modelling and in the understanding of hydro-meteorological pathways. The use of the deuterium excess imposes strict requirements on the accuracy of deuterium and oxygen-18 analysis. A GNIP-based worldwide documentation of quality control regarding sampling, shipping and measurements is needed. The IAEA/WMO database and other isotope data sets should be included in the World Data Center A for palaeo-climatology. Refs, figs, tabs

  1. Generalization of international centrifugal zone growth of metal-ceramic composites. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    Sekerka, R.F.; Hartzell, R.A.

    1976-08-01

    The electric and temperature fields within inductively heated materials have been calculated in order to better understand the essential features of the crystal growth process called Internal Centrifugal Zone Growth (ICZG). A complicated two-dimensional problem has been studied via a simple one-dimensional model which applies to infinitely long samples heated by infinitely long induction coils. Two such one-dimensional models are presented. In the first model, all material properties of the sample are assumed to be independent of temperature. The coupled differential equations determining the electric field and temperature distributions within the sample are solved analytically. Resulting profiles of temperature and electromagnetic fields within the sample provide a basis for more sophisticated models. The second model deals with materials (e.g., oxides) whose electrical conductivities are very low at room temperature but increase significantly with temperature. The differential equations for electromagnetic and temperature fields are consequently strongly coupled, resulting in multiple steady state solutions, some of which are unstable. An understanding of this instability is of utmost importance with regard to crystal growth via ICZG, because it has been observed that an increase in the electrical conductivity of the sample when melting occurs can cause a catastrophic increase in surface temperature. The modeling predicts, however, that the instability can be controlled through a judicious choice of RF frequency, sample size, and sample alloying. Progress has been made in solving the two-dimensional differential equations. Many problems are encountered that are not present in one-dimensional modeling. The method of solution is outlined, but no solutions have yet been obtained.

  2. Generalization of international centrifugal zone growth of metal-ceramic composites. Technical report

    International Nuclear Information System (INIS)

    Sekerka, R.F.; Hartzell, R.A.

    1976-08-01

    The electric and temperature fields within inductively heated materials have been calculated in order to better understand the essential features of the crystal growth process called Internal Centrifugal Zone Growth (ICZG). A complicated two-dimensional problem has been studied via a simple one-dimensional model which applies to infinitely long samples heated by infinitely long induction coils. Two such one-dimensional models are presented. In the first model, all material properties of the sample are assumed to be independent of temperature. The coupled differential equations determining the electric field and temperature distributions within the sample are solved analytically. Resulting profiles of temperature and electromagnetic fields within the sample provide a basis for more sophisticated models. The second model deals with materials (e.g., oxides) whose electrical conductivities are very low at room temperature but increase significantly with temperature. The differential equations for electromagnetic and temperature fields are consequently strongly coupled, resulting in multiple steady state solutions, some of which are unstable. An understanding of this instability is of utmost importance with regard to crystal growth via ICZG, because it has been observed that an increase in the electrical conductivity of the sample when melting occurs can cause a catastrophic increase in surface temperature. The modeling predicts, however, that the instability can be controlled through a judicious choice of RF frequency, sample size, and sample alloying. Progress has been made in solving the two-dimensional differential equations. Many problems are encountered that are not present in one-dimensional modeling. The method of solution is outlined, but no solutions have yet been obtained

  3. International

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    This rubric reports on 10 short notes about international economical facts about nuclear power: Electricite de France (EdF) and its assistance and management contracts with Eastern Europe countries (Poland, Hungary, Bulgaria); Transnuclear Inc. company (a 100% Cogema daughter company) acquired the US Vectra Technologies company; the construction of the Khumo nuclear power plant in Northern Korea plays in favour of the reconciliation between Northern and Southern Korea; the delivery of two VVER 1000 Russian reactors to China; the enforcement of the cooperation agreement between Euratom and Argentina; Japan requested for the financing of a Russian fast breeder reactor; Russia has planned to sell a floating barge-type nuclear power plant to Indonesia; the control of the Swedish reactor vessels of Sydkraft AB company committed to Tractebel (Belgium); the renewal of the nuclear cooperation agreement between Swiss and USA; the call for bids from the Turkish TEAS electric power company for the building of the Akkuyu nuclear power plant answered by three candidates: Atomic Energy of Canada Limited (AECL), Westinghouse (US) and the French-German NPI company. (J.S.)

  4. The impact of dermatology consultation on diagnostic accuracy and antibiotic use among patients with suspected cellulitis seen at outpatient internal medicine offices: a randomized clinical trial.

    Science.gov (United States)

    Arakaki, Ryan Y; Strazzula, Lauren; Woo, Elaine; Kroshinsky, Daniela

    2014-10-01

    Cellulitis is a common and costly problem, often diagnosed in the outpatient setting. Many cutaneous conditions may clinically mimic cellulitis, but little research has been done to assess the magnitude of the problem. To determine if obtaining dermatology consultations in the outpatient primary care setting could assist in the diagnosis of pseudocellulitic conditions and reduce the rate of unnecessary antibiotic use. Nonblinded randomized clinical trial of competent adults who were diagnosed as having cellulitis by their primary care physicians (PCPs), conducted at outpatient internal medical primary care offices affiliated with a large academic medical center. Outpatient dermatology consultation. Primary outcomes were final diagnosis, antibiotic use, and need for hospitalization. A total of 29 patients (12 male and 17 female) were enrolled for participation in this trial. Nine patients were randomized to continue with PCP management (control group), and 20 patients were randomized to receive a dermatology consultation (treatment group). Of the 20 patients in the dermatology consultation group, 2 (10%) were diagnosed as having cellulitis. In the control group, all 9 patients were diagnosed as having cellulitis by PCPs, but dermatologist evaluation determined that 6 (67%) of these patients had a psuedocellulitis rather than true infection. All 9 patients (100%) in the control group were treated for cellulitis with antibiotics vs 2 patients (10%) in the treatment group (P Dermatology consultation in the primary care setting improves the diagnostic accuracy of suspected cellulitis and decreases unnecessary antibiotic use in patients with pseudocellulitic conditions. Obtaining an outpatient dermatology consultation may be a cost-effective strategy that improves quality of care. clinicaltrials.gov Identifier:NCT01795092.

  5. Rasch Analysis of the Premature Ejaculation Diagnostic Tool (PEDT and the International Index of Erectile Function (IIEF in an Iranian Sample of Prostate Cancer Patients.

    Directory of Open Access Journals (Sweden)

    Chung-Ying Lin

    Full Text Available Male sexual dysfunction is an increasing problem across a variety of general and clinical populations, such as cancer populations; especially among prostate cancer patients who tend to receive treatments that often result in erectile dysfunction (ED and/or premature ejaculation (PE. Therefore, in order to diagnose ED and PE in these populations, adequate and efficient instruments such as the International Index of Erectile Function 5-item version (IIEF-5 and the Premature Ejaculation Diagnostic Tool (PEDT are needed. However, since this is an important topic additional evidence of psychometric properties of the IIEF-5 and the PEDT in such samples are required. Thus the aim of the present study was to use Rasch models to investigate the construct validity, local dependency, score order, and differential item functioning (DIF of both questionnaires in a sample of prostate cancer patients.Prostate cancer patients (n = 1058, mean±SD age = 64.07±6.84 years who visited urology clinics were invited to fill out the IIEF-5 and the PEDT. Construct validity was examined using infit and outfit mean square (MnSq and local dependency using correlations between each two residual Rasch scores. Score order was investigated using step and average measures of difficulty and DIF using DIF contrast.All IIEF-5 and PEDT items had acceptable infit and outfit MnSq. Step measures revealed that all but two items had disordered categories in terms of scores 1 to 3. Only one local dependency was found, and no items displayed DIF across age, educational level, and help seeking.The results showed that both the IIEF-5 and the PEDT had sound psychometric properties in the Rasch analyses, although some score disordering could be detected in both instruments. The results of no DIF items in both instruments suggest using them to compare ED and PE across age and educational level is adequate.

  6. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for clinical and research applications: recommendations of the international RDC/TMD consortium network and orofacial pain special interest group

    NARCIS (Netherlands)

    Schiffman, E.; Ohrbach, R.; Truelove, E.; Look, J.; Anderson, G.; Goulet, J.P.; List, T.; Svensson, P.; Gonzalez, Y.; Lobbezoo, F.; Michelotti, A.; Brooks, S.L.; Ceusters, W.; Drangsholt, M.; Ettlin, D.; Gaul, C.; Goldberg, L.J.; Haythornthwaite, J.A.; Hollender, L.; Jensen, R.; John, M.T.; De Laat, A.; de Leeuw, R.; Maixner, W.; van der Meulen, M.; Murray, G.M.; Nixdorf, D.R.; Palla, S.; Petersson, A.; Pionchon, P.; Smith, B.; Visscher, C.M.; Zakrzewska, J.; Dworkin, S.F.

    2014-01-01

    AIMS: The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥

  7. Size-confined fixed-composition and composition-dependent engineered band gap alloying induces different internal structures in L-cysteine-capped alloyed quaternary CdZnTeS quantum dots

    Science.gov (United States)

    Adegoke, Oluwasesan; Park, Enoch Y.

    2016-06-01

    The development of alloyed quantum dot (QD) nanocrystals with attractive optical properties for a wide array of chemical and biological applications is a growing research field. In this work, size-tunable engineered band gap composition-dependent alloying and fixed-composition alloying were employed to fabricate new L-cysteine-capped alloyed quaternary CdZnTeS QDs exhibiting different internal structures. Lattice parameters simulated based on powder X-ray diffraction (PXRD) revealed the internal structure of the composition-dependent alloyed CdxZnyTeS QDs to have a gradient nature, whereas the fixed-composition alloyed QDs exhibited a homogenous internal structure. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) analysis confirmed the size-confined nature and monodispersity of the alloyed nanocrystals. The zeta potential values were within the accepted range of colloidal stability. Circular dichroism (CD) analysis showed that the surface-capped L-cysteine ligand induced electronic and conformational chiroptical changes in the alloyed nanocrystals. The photoluminescence (PL) quantum yield (QY) values of the gradient alloyed QDs were 27-61%, whereas for the homogenous alloyed QDs, the PL QY values were spectacularly high (72-93%). Our work demonstrates that engineered fixed alloying produces homogenous QD nanocrystals with higher PL QY than composition-dependent alloying.

  8. FEATURES OF ELECTROMECHANICAL ACOUSTIC ENERGY CONVERSION BY CYLINDRICAL PIEZOCERAMIC TRANSDUCERS WITH INTERNAL SCREENS IN COMPOSITION OF FLAT SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. G. Leiko

    2018-01-01

    Full Text Available The problem of sound emission is considered by a system formed from cylindrical piezoceramic radiators with internal acoustically soft screens. Longitudinal axis of emitters lie in one plane. This system is characterized by the interaction of electric, mechanical and acoustic fields in the process of conversion electrical energy to acoustical energy and acoustic fields in the process of forming them in the environments. The purpose of the work is to determine the peculiarities of the electromechanical acoustic transformation of energy by cylindrical piezoceramic radiators with internal screens in the composition of flat systems, taking into account all types of interaction.The research was carried out by the method of bound fields in multiply connected domains with the use of addition theorems for the cylindrical wave functions. The physical fields arising from the emission of sound by such a system are determined by the joint solution of the system of differential equations: the wave equation; equations of motion of thin piezoceramic shells with circular polarization in displacements; the equations of forced electrostatics for piezoceramics at given boundary conditions, the conditions of conjugation of fields at the boundaries of the division of domains and electric conditions.The solution of the problem is reduced to the solution of an infinite system of linear algebraic equations with respect to unknown coefficients of field expansions.An analysis of the results of numerical calculations, performed on the basis of the obtained analytical relations, called to establish a number of features in the electromechanical acoustic transformation of energy by emitters in the composition of flat systems. They include: the role of acoustic interaction in the process of energy conversion; determination of the mechanism of quantitative assessment of the influence of interaction on these processes; the dependence of the degree of violation of the radial

  9. An in vivo evaluation of PLLA/PLLA-gHA nano-composite for internal fixation of mandibular bone fractures.

    Science.gov (United States)

    Peng, Weihai; Zheng, Wei; Shi, Kai; Wang, Wangshu; Shao, Ying; Zhang, Duo

    2015-11-09

    Internal fixation of bone fractures using biodegradable poly(L-lactic-acid) (PLLA)-based materials has attracted the attention of many researchers. In the present study, 36 male beagle dogs were randomly assigned to two groups: PLLA/PLLA-gHA (PLLA-grafted hydroxyapatite) group and PLLA group. PLLA/PLLA-gHA and PLLA plates were embedded in the muscular bags of the erector spinae and also implanted to fix mandibular bone fractures in respective groups. At 1, 2, 3, 6, 9, and 12 months postoperatively, the PLLA/PLLA-gHA and PLLA plates were evaluated by adsorption and degradation tests, and the mandibles were examined through radiographic analysis, biomechanical testing, and histological analysis. The PLLA/PLLA-gHA plates were non-transparent and showed a creamy white color, and the PLLA plates were transparent and faint yellow in color. At all time points following surgery, adsorption and degradation of the PLLA/PLLA-gHA plates were significantly less than those of the PLLA plates, and the lateral and longitudinal bending strengths of the surgically treated mandibles of the beagle dogs in the PLLA/PLLA-gHA group were significantly greater than those of the PLLA group and reached almost the value of intact mandibles at 12 months postoperatively. Additionally, relatively rapid bone healing was observed in the PLLA/PLLA-gHA group with the formation of new lamellar bone tissues at 12 months after the surgery. The PLLA/PLLA-gHA nano-composite can be employed as a biodegradable material for internal fixation of mandibular bone fractures.

  10. An in vivo evaluation of PLLA/PLLA-gHA nano-composite for internal fixation of mandibular bone fractures

    International Nuclear Information System (INIS)

    Peng, Weihai; Shi, Kai; Wang, Wangshu; Shao, Ying; Zhang, Duo; Zheng, Wei

    2015-01-01

    Internal fixation of bone fractures using biodegradable poly(L-lactic-acid) (PLLA)-based materials has attracted the attention of many researchers. In the present study, 36 male beagle dogs were randomly assigned to two groups: PLLA/PLLA-gHA (PLLA-grafted hydroxyapatite) group and PLLA group. PLLA/PLLA-gHA and PLLA plates were embedded in the muscular bags of the erector spinae and also implanted to fix mandibular bone fractures in respective groups. At 1, 2, 3, 6, 9, and 12 months postoperatively, the PLLA/PLLA-gHA and PLLA plates were evaluated by adsorption and degradation tests, and the mandibles were examined through radiographic analysis, biomechanical testing, and histological analysis. The PLLA/PLLA-gHA plates were non-transparent and showed a creamy white color, and the PLLA plates were transparent and faint yellow in color. At all time points following surgery, adsorption and degradation of the PLLA/PLLA-gHA plates were significantly less than those of the PLLA plates, and the lateral and longitudinal bending strengths of the surgically treated mandibles of the beagle dogs in the PLLA/PLLA-gHA group were significantly greater than those of the PLLA group and reached almost the value of intact mandibles at 12 months postoperatively. Additionally, relatively rapid bone healing was observed in the PLLA/PLLA-gHA group with the formation of new lamellar bone tissues at 12 months after the surgery. The PLLA/PLLA-gHA nano-composite can be employed as a biodegradable material for internal fixation of mandibular bone fractures. (paper)

  11. PEGylation of Phytantriol-Based Lyotropic Liquid Crystalline Particles-The Effect of Lipid Composition, PEG Chain Length, and Temperature on the Internal Nanostructure

    DEFF Research Database (Denmark)

    Nilsson, Christa; Ostergaard, Jesper; Larsen, Susan Weng

    2014-01-01

    of these lipidic nonlamellar liquid crystalline particles by using DSPE-mPEGs with three different block lengths of the hydrophilic PEG segment. The effects of lipid composition, PEG chain length, and temperature on the morphology and internal nanostructure of these self-assembled lipidic aqueous dispersions based...

  12. A 12-week rehabilitation program improves body composition, pain sensation, and internal/external torques of baseball pitchers with shoulder impingement symptom.

    Science.gov (United States)

    Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok

    2014-02-01

    The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment.

  13. Substance dependence and non-dependence in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD): can an identical conceptualization be achieved?

    Science.gov (United States)

    Saunders, John B

    2006-09-01

    This review summarizes the history of the development of diagnostic constructs that apply to repetitive substance use, and compares and contrasts the nature, psychometric performance and utility of the major diagnoses in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and International Classification of Diseases (ICD) diagnostic systems. The available literature was reviewed with a particular focus on diagnostic concepts that are relevant for clinical and epidemiological practice, and so that research questions could be generated that might inform the development of the next generation of DSM and ICD diagnoses. The substance dependence syndrome is a psychometrically robust and clinically useful construct, which applies to a range of psychoactive substances. The differences between the DSM fourth edition (DSM-IV) and the ICD tenth edition (ICD-10) versions are minimal and could be resolved. DSM-IV substance abuse performs moderately well but, being defined essentially by social criteria, may be culture-dependent. ICD-10 harmful substance use performs poorly as a diagnostic entity. There are good prospects for resolving many of the differences between the DSM and ICD systems. A new non-dependence diagnosis is required. There would also be advantages in a subthreshold diagnosis of hazardous or risky substance use being incorporated into the two systems. Biomedical research can be drawn upon to define a psychophysiological 'driving force' which could underpin a broad spectrum of substance use disorders.

  14. Fibre reinforced composites '84; Proceedings of the International Conference, University of Liverpool, England, April 3-5, 1984

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Among the topics discussed are phenolic resin matrix composites for high temperature and fire-exposure applications, novel resins for fiber-reinforced composite productivity improvement, the use of engineering textiles for mechanical property improvement in composites, the significance of aramid fiber reinforcement in composites, the energy absorption properties of Sheet Metal Compounds (SMCs) under crash conditions, and SMC impact behavior variations with temperature. Also covered are CFRP applications in high performance structures, composite helicopter main rotor blade technology, composite vehicular leaf springs, carbon fiber-reinforced thermoplastics, filament winding development status, the injection processing of fiber-reinforced thermoplastics, civil aircraft composite structure certification, composite radomes, design procedures for short fiber-reinforced thermoplastics, the strength limitations of mechanically fastened lap joints, environmental fatigue and creep in glass-reinforced materials, the effects of moisture on high performance laminates, the environmental behavior of SMC, and corrugated composites.

  15. Refined Models for an Analysis of Internal and External Buckling Modes of a Monolayer in a Layered Composite

    Science.gov (United States)

    Paimushin, V. N.

    2017-11-01

    For an analysis of internal and external buckling modes of a monolayer inside or at the periphery of a layered composite, refined geometrically nonlinear equations are constructed. They are based on modeling the monolayer as a thin plate interacting with binder layers at the points of boundary surfaces. The binder layer is modeled as a transversely soft foundation. It is assumed the foundations, previously compressed in the transverse direction (the first loading stage), have zero displacements of its external boundary surfaces at the second loading stage, but the contact interaction of the plate with foundations occurs without slippage or delamination. The deformation of the plate at a medium flexure is described by geometrically nonlinear relations of the classical plate theory based on the Kirchhoff-Love hypothesis (the first variant) or the refined Timoshenko model with account of the transverse shear and compression (the second variant). The foundation is described by linearized 3D equations of elasticity theory, which are simplified within the framework of the model of a transversely soft layer. Integrating the linearized equations along the transverse coordinate and satisfying the kinematic joining conditions of the plate with foundations, with account of their initial compression in the thickness direction, a system of 2D geometrically nonlinear equations and appropriate boundary conditions are derived. These equations describe the contact interaction between elements of the deformable system. The relations obtained are simplified for the case of a symmetric stacking sequence.

  16. Validez interna y utilidad diagnóstica del Eating Disorders Inventory en mujeres mexicanas Internal validity and diagnostic utility of the Eating Disorder Inventory, in Mexican women

    Directory of Open Access Journals (Sweden)

    Eduardo García-García

    2003-06-01

    Full Text Available OBJETIVO: Determinar la utilidad diagnóstica y la validez interna del Eating Disorder Inventory (EDI-2 en mujeres mexicanas. MATERIAL Y MÉTODOS: De octubre de 2000 a enero de 2001 se invitó a participar a todas las mujeres que a juicio de los psiquiatras de la consulta de anorexia del Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, de la Ciudad de México, padecían anorexia nervosa o bulimia, sin otra patología psiquiátrica. Es un estudio observacional, comparativo, transversal y prolectivo de dos grupos de mujeres: pacientes de la Clínica de Anorexia del Instituto y de una escuela de la Ciudad de México. Se realizó una entrevista clínica estructurada como estándar de oro (SCID/Manual Diagnóstico y Estadístico de los Trastornos Mentales y la aplicación del Eating Disorder Inventory. El análisis estadístico incluyó t de Student para muestras independientes, coeficiente alpha de Cronbach, sensibilidad, especificidad, valor predictivo positivo y negativo. RESULTADOS: No hubo diferencias significativas en peso, talla e índice de masa corporal entre los grupos. La edad de las mujeres sin trastorno alimentario fue menor (16.7±2.8 vs. 19.9±4.3, p=0.004. La calificación total del Eating Disorder Inventory fue claramente diferente (53.8±32.4 mujeres sin trastorno alimentario vs. 146.3±45.6 pacientes, pOBJECTIVE: To assess the diagnostic utility and internal validity of the Eating Disorder Inventory (EDI-2 in Mexican women. MATERIAL AND METHODS: An observational, cross-sectional study was conducted between October 2000 and January 2001. The sample population consisted of two groups of women: patients diagnosed with anorexia nervosa or bulimia, but no other psychiatric pathology, seen by psychiatrists at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán (National Institute of Medical Sciences and Nutrition Salvador Zubirán, and a randomly selected sample of women from a school in

  17. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  18. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  19. The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R): A Scale to Assist the Diagnosis of Autism Spectrum Disorder in Adults--An International Validation Study

    Science.gov (United States)

    Ritvo, Riva Ariella; Ritvo, Edward R.; Guthrie, Donald; Ritvo, Max J.; Hufnagel, Demetra H.; McMahon, William; Tonge, Bruce; Mataix-Cols, David; Jassi, Amita; Attwood, Tony; Eloff, Johann

    2011-01-01

    The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R) is a valid and reliable instrument to assist the diagnosis of adults with Autism Spectrum Disorders (ASD). The 80-question scale was administered to 779 subjects (201 ASD and 578 comparisons). All ASD subjects met inclusion criteria: DSM-IV-TR, ADI/ADOS diagnoses and standardized IQ…

  20. Polychromatic holographic plasma diagnostics

    International Nuclear Information System (INIS)

    Zhiglinskij, A.G.; Morozov, A.O.

    1992-01-01

    Review of holographic interferometry properties is performed and advantages of this method by plasma diagnostics are indicated. Main results obtained by the method of holographic interferometry in studies of various-type plasmas are considered. Special attention is paid to multiwave plasma diagnostics, the necessity of which is related as a rule to multicomponent composition of plasma. The eight laser and gas-discharge sources and holographic schemes, which make it possible to realize plasma polychromatic and holographic interferometry, are considered. The advantages of the method are demonstrated by examples of polychromatic holographic diagnostics of arc discharge and discharge in a hollow cathode. Review of theoretical works determining the applicability area of resonance polychromatic interferometry is carried out

  1. Diagnostic Imaging Workshop

    International Nuclear Information System (INIS)

    Sociedad Argentina de Fisica Medica

    2012-01-01

    The American Association of Physicist in Medicine (AAPM), the International Organization for Medical Physics (IOMP) and the Argentina Society of Medical Physics (SAFIM) was organized the Diagnostic Imaging Workshop 2012, in the city of Buenos Aires, Argentina. This workshop was an oriented training and scientific exchange between professionals and technicians who work in medical physics, especially in the areas of diagnostic imaging, nuclear medicine and radiotherapy, with special emphasis on the use of multimodal imaging for radiation treatment, planning as well of quality assurance associates.

  2. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  3. The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R): a scale to assist the diagnosis of Autism Spectrum Disorder in adults: an international validation study.

    Science.gov (United States)

    Ritvo, Riva Ariella; Ritvo, Edward R; Guthrie, Donald; Ritvo, Max J; Hufnagel, Demetra H; McMahon, William; Tonge, Bruce; Mataix-Cols, David; Jassi, Amita; Attwood, Tony; Eloff, Johann

    2011-08-01

    The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R) is a valid and reliable instrument to assist the diagnosis of adults with Autism Spectrum Disorders (ASD). The 80-question scale was administered to 779 subjects (201 ASD and 578 comparisons). All ASD subjects met inclusion criteria: DSM-IV-TR, ADI/ADOS diagnoses and standardized IQ testing. Mean scores for each of the questions and total mean ASD vs. the comparison groups' scores were significantly different (p < .0001). Concurrent validity with Constantino Social Responsiveness Scale-Adult = 95.59%. Sensitivity = 97%, specificity = 100%, test-retest reliability r = .987. Cronbach alpha coefficients for the subscales and 4 derived factors were good. We conclude that the RAADS-R is a useful adjunct diagnostic tool for adults with ASD.

  4. Characterisation of micro-sized and nano-sized tungsten oxide-epoxy composites for radiation shielding of diagnostic X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Noor Azman, N.Z. [Department of Imaging and Applied Physics, Curtin University, GPO Box U1987, Perth, WA 6845 Australia (Australia); School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); Siddiqui, S.A. [Department of Imaging and Applied Physics, Curtin University, GPO Box U1987, Perth, WA 6845 Australia (Australia); Low, I.M., E-mail: j.low@curtin.edu.au [Department of Imaging and Applied Physics, Curtin University, GPO Box U1987, Perth, WA 6845 Australia (Australia)

    2013-12-01

    Characteristics of X-ray transmissions were investigated for epoxy composites filled with 2–10 vol% WO{sub 3} loadings using synchrotron X-ray absorption spectroscopy (XAS) at 10–40 keV. The results obtained were used to determine the equivalent X-ray energies for the operating X-ray tube voltages of mammography and radiology machines. The results confirmed the superior attenuation ability of nano-sized WO{sub 3}-epoxy composites in the energy range of 10–25 keV when compared to their micro-sized counterparts. However, at higher synchrotron radiation energies (i.e., 30–40 keV), the X-ray transmission characteristics were similar with no apparent size effect for both nano-sized and micro-sized WO{sub 3}-epoxy composites. The equivalent X-ray energies for the operating X-ray tube voltages of the mammography unit (25–49 kV) were in the range of 15–25 keV. Similarly, for a radiology unit operating at 40–60 kV, the equivalent energy range was 25–40 keV, and for operating voltages greater than 60 kV (i.e., 70–100 kV), the equivalent energy was in excess of 40 keV. The mechanical properties of epoxy composites increased initially with an increase in the filler loading but a further increase in the WO{sub 3} loading resulted in deterioration of flexural strength, modulus and hardness. - Highlights: • Nano-sized WO{sub 3}-epoxy composites have superior x-ray shielding capability. • No size effect in x-ray attenuation was observed at 30–40 keV. • An optimum filler loading for improving the mechanical properties of WO{sub 3}-epoxy composites.

  5. ORION laser target diagnostics

    International Nuclear Information System (INIS)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.

    2012-01-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  6. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  7. Diagnostic informative value of gastroduodenal regulatory peptides of the blood serum on an empty stomach and after test breakfasts of various compositions

    International Nuclear Information System (INIS)

    Ablyazov, A.A.; Korot'ko, G.F.

    1992-01-01

    Gastrin, secretin and cholecystokinin were determined by a radioimmunoassay in healthy persons (19) and in patients with peptic ulcer (13) on an empty stomach and after test breakfasts with different nutrients. In the healthy persons the blood concentration of regulatory peptides was lower than in the patients. Breakfasts increased the concentrations of gastrin, secretin and cholecystokinin in the patients much more than in the controls. Some differences in changes of the blood concentration of peptides were noted with regard to a type of test breakfast. However differentiated reactions of the endocrine apparatus of the gastroduodenal complex in response to the breakfasts were not a reliable functional and diagnostic criterion

  8. Hygroscopic behavior and chemical composition evolution of internally mixed aerosols composed of oxalic acid and ammonium sulfate

    Science.gov (United States)

    Wang, Xiaowei; Jing, Bo; Tan, Fang; Ma, Jiabi; Zhang, Yunhong; Ge, Maofa

    2017-10-01

    Although water uptake of aerosol particles plays an important role in the atmospheric environment, the effects of interactions between components on chemical composition and hygroscopicity of particles are still not well constrained. The hygroscopic properties and phase transformation of oxalic acid (OA) and mixed particles composed of ammonium sulfate (AS) and OA with different organic to inorganic molar ratios (OIRs) have been investigated by using confocal Raman spectroscopy. It is found that OA droplets first crystallize to form OA dihydrate at 71 % relative humidity (RH), and further lose crystalline water to convert into anhydrous OA around 5 % RH during the dehydration process. The deliquescence and efflorescence point for AS is determined to be 80.1 ± 1.5 % RH and 44.3 ± 2.5 % RH, respectively. The observed efflorescence relative humidity (ERH) for mixed OA / AS droplets with OIRs of 1 : 3, 1 : 1 and 3 : 1 is 34.4 ± 2.0, 44.3 ± 2.5 and 64.4 ± 3.0 % RH, respectively, indicating the elevated OA content appears to favor the crystallization of mixed systems at higher RH. However, the deliquescence relative humidity (DRH) of AS in mixed OA / AS particles with OIRs of 1 : 3 and 1 : 1 is observed to occur at 81.1 ± 1.5 and 77 ± 1.0 % RH, respectively. The Raman spectra of mixed OA / AS droplets indicate the formation of ammonium hydrogen oxalate (NH4HC2O4) and ammonium hydrogen sulfate (NH4HSO4) from interactions between OA and AS in aerosols during the dehydration process on the time scale of hours, which considerably influence the subsequent deliquescence behavior of internally mixed particles with different OIRs. The mixed OA / AS particles with an OIR of 3 : 1 exhibit no deliquescence transition over the RH range studied due to the considerable transformation of (NH4)2SO4 into NH4HC2O4 with a high DRH. Although the hygroscopic growth of mixed OA / AS droplets is comparable to that of AS or OA at high RH during the dehydration process, Raman growth

  9. Hygroscopic behavior and chemical composition evolution of internally mixed aerosols composed of oxalic acid and ammonium sulfate

    Directory of Open Access Journals (Sweden)

    X. Wang

    2017-10-01

    Full Text Available Although water uptake of aerosol particles plays an important role in the atmospheric environment, the effects of interactions between components on chemical composition and hygroscopicity of particles are still not well constrained. The hygroscopic properties and phase transformation of oxalic acid (OA and mixed particles composed of ammonium sulfate (AS and OA with different organic to inorganic molar ratios (OIRs have been investigated by using confocal Raman spectroscopy. It is found that OA droplets first crystallize to form OA dihydrate at 71 % relative humidity (RH, and further lose crystalline water to convert into anhydrous OA around 5 % RH during the dehydration process. The deliquescence and efflorescence point for AS is determined to be 80.1 ± 1.5 % RH and 44.3 ± 2.5 % RH, respectively. The observed efflorescence relative humidity (ERH for mixed OA ∕ AS droplets with OIRs of 1 : 3, 1 : 1 and 3 : 1 is 34.4 ± 2.0, 44.3 ± 2.5 and 64.4 ± 3.0 % RH, respectively, indicating the elevated OA content appears to favor the crystallization of mixed systems at higher RH. However, the deliquescence relative humidity (DRH of AS in mixed OA ∕ AS particles with OIRs of 1 : 3 and 1 : 1 is observed to occur at 81.1 ± 1.5 and 77 ± 1.0 % RH, respectively. The Raman spectra of mixed OA ∕ AS droplets indicate the formation of ammonium hydrogen oxalate (NH4HC2O4 and ammonium hydrogen sulfate (NH4HSO4 from interactions between OA and AS in aerosols during the dehydration process on the time scale of hours, which considerably influence the subsequent deliquescence behavior of internally mixed particles with different OIRs. The mixed OA ∕ AS particles with an OIR of 3 : 1 exhibit no deliquescence transition over the RH range studied due to the considerable transformation of (NH42SO4 into NH4HC2O4 with a high DRH. Although the hygroscopic growth of mixed OA

  10. The Bosnian version of the international self-report measure of posttraumatic stress disorder, the Posttraumatic Stress Diagnostic Scale, is reliable and valid in a variety of different adult samples affected by war

    Directory of Open Access Journals (Sweden)

    Rosner Rita

    2005-02-01

    Full Text Available Abstract Background The aim of the present study was to assess the internal consistency and discriminant and convergent validity of the Bosnian version of a self-report measure of posttraumatic stress disorder (PTSD, the Posttraumatic Stress Diagnostic Scale (PTDS. The PTDS yields both a PTSD diagnosis according to the Diagnostic and Statistical Manual of Mental Disorders 4th edition (DSM-IV and a measure of symptom severity. Methods 812 people living in Sarajevo or in Banja Luka in Bosnia-Herzegovina, of whom the majority had experienced a high number of traumatic war events, were administered the PTDS and other measures of trauma-related psychopathology. The psychometric properties of the instrument were assessed using Cronbach's alpha and principal components analysis, and its construct validity was assessed via Spearman correlation coefficients with the other instruments. Results The PTDS and its subscales demonstrated high internal consistency. The principal components revealed by an exploratory analysis are broadly consistent with the DSM-IV subscales except that they reproduce some previously reported difficulties with the "numbing" items from the avoidance subscale. The construct validity of the PTDS was supported by appropriate correlations with other relevant measures of trauma related psychopathology. Conclusion The Bosnian version of the PTDS thus appears to be a time-economic and psychometrically sound measure for screening and assessing current PTSD. This self-report measure awaits further validation by interview methods.

  11. Litigations in diagnostic radiology

    International Nuclear Information System (INIS)

    Patil, Ranjit

    2014-01-01

    There are various regulatory bodies at the international and national level, which lay down norms for radiation protection. These are the International Commission for Radiation Protection (ICRP) the National Commission for Radiation Protection (NCRP) in America, and the Atomic Energy Regulatory Board (AERB) in India. These bodies recommend norms on various radiation issues. Radiography and radiology are two key tools for diagnosing and treating diseases. Recently there are concerns about the effect of ionizing radiation on man and the frequent use of diagnostic radiographs. The professionals are expected to conduct their actions according to guidelines which reflect new information and changing technology in diagnostic radiography. Failure to do so may have severe legal consequences. Patient protection is a matter of normal course but knowledge and awareness of the legal issues is important to avoid legal hassles. Implications of the radiation protection guidelines are discussed. (author)

  12. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  13. Letters for the international exchange of publications a guide to their composition in English, French, German, Russian and Spanish

    CERN Document Server

    Allardyce, Alex

    2017-01-01

    The International Federation of Library Associations and Institutions (IFLA) is the leading international body representing the interests of library and information services and their users. It is the global voice of the information profession. The series IFLA Publications deals with many of the means through which libraries, information centres, and information professionals worldwide can formulate their goals, exert their influence as a group, protect their interests, and find solutions to global problems.

  14. Molecular Diagnostics of ?-Thalassemia

    OpenAIRE

    Atanasovska, B; Bozhinovski, G; Chakalova, L; Kocheva, S; Karanfilski, O; Plaseska-Karanfiska, D

    2012-01-01

    A high-quality hemoglobinopathy diagnosis is based on the results of a number of tests including assays for molecular identification of causative mutations. We describe the current diagnostic strategy for the identification of ?-thalassemias and hemoglobin (Hb) variants at the International Reference Laboratory for Haemoglobinopathies, Research Centre for Genetic Engineering and Biotechnology (RCGEB) ?Georgi D. Efremov,? Skopje, Republic of Macedonia. Our overall approach and most of the meth...

  15. Characterisation of micro-sized and nano-sized tungsten oxide-epoxy composites for radiation shielding of diagnostic X-rays.

    Science.gov (United States)

    Azman, N Z Noor; Siddiqui, S A; Low, I M

    2013-12-01

    Characteristics of X-ray transmissions were investigated for epoxy composites filled with 2-10 vol% WO3 loadings using synchrotron X-ray absorption spectroscopy (XAS) at 10-40 keV. The results obtained were used to determine the equivalent X-ray energies for the operating X-ray tube voltages of mammography and radiology machines. The results confirmed the superior attenuation ability of nano-sized WO3-epoxy composites in the energy range of 10-25 keV when compared to their micro-sized counterparts. However, at higher synchrotron radiation energies (i.e., 30-40 keV), the X-ray transmission characteristics were similar with no apparent size effect for both nano-sized and micro-sized WO3-epoxy composites. The equivalent X-ray energies for the operating X-ray tube voltages of the mammography unit (25-49 kV) were in the range of 15-25 keV. Similarly, for a radiology unit operating at 40-60 kV, the equivalent energy range was 25-40 keV, and for operating voltages greater than 60 kV (i.e., 70-100 kV), the equivalent energy was in excess of 40 keV. The mechanical properties of epoxy composites increased initially with an increase in the filler loading but a further increase in the WO3 loading resulted in deterioration of flexural strength, modulus and hardness. © 2013.

  16. Analyzing the diagnostic accuracy of the causes of spinal pain at neurology hospital in accordance with the International Classification of Diseases

    Directory of Open Access Journals (Sweden)

    I. G. Mikhailyuk

    2014-01-01

    Full Text Available Spinal pain is of great socioeconomic significance as it is widely prevalent and a common cause of disability. However, the diagnosis of its true causes frequently leads to problems. A study has been conducted to evaluate the accuracy of a clinical diagnosis and its coding in conformity with the International Classification of Diseases. The diagnosis of vertebral osteochondrosis and the hypodiagnosis of nonspecific and nonvertebrogenic pain syndromes have been found to be unreasonably widely used. Ways to solve these problems have been proposed, by applying approaches to diagnosing the causes of spinal pain in accordance with international practice.

  17. Process Modelling of Curing Process-Induced Internal Stress and Deformation of Composite Laminate Structure with Elastic and Viscoelastic Models

    Science.gov (United States)

    Li, Dongna; Li, Xudong; Dai, Jianfeng

    2018-06-01

    In this paper, two kinds of transient models, the viscoelastic model and the linear elastic model, are established to analyze the curing deformation of the thermosetting resin composites, and are calculated by COMSOL Multiphysics software. The two models consider the complicated coupling between physical and chemical changes during curing process of the composites and the time-variant characteristic of material performance parameters. Subsequently, the two proposed models are implemented respectively in a three-dimensional composite laminate structure, and a simple and convenient method of local coordinate system is used to calculate the development of residual stresses, curing shrinkage and curing deformation for the composite laminate. Researches show that the temperature, degree of curing (DOC) and residual stresses during curing process are consistent with the study in literature, so the curing shrinkage and curing deformation obtained on these basis have a certain referential value. Compared the differences between the two numerical results, it indicates that the residual stress and deformation calculated by the viscoelastic model are more close to the reference value than the linear elastic model.

  18. Diagnostic dilemma

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Dobrovolny, Robert; Nazarenko, Irina

    2011-01-01

    Fabry disease, an X-linked lysosomal storage disorder, results from the deficient activity of a-galactosidase A (a-Gal A). In affected males, the clinical diagnosis is confirmed by the markedly decreased a-Gal A activity. However, in female heterozygotes, the a-Gal A activity can range from low t...... on enzyme replacement therapy. Thus, gene dosage analyses can detect large deletions (>50bp) in suspect heterozygotes for X-linked and autosomal dominant diseases that are "sequencing cryptic," resolving molecular diagnostic dilemmas....... to normal due to random X-chromosomal inactivation, and diagnostic confirmation requires identification of the family's a-Gal A gene mutation. In a young female who had occasional acroparesthesias, corneal opacities, and 15 to 50% of the lower limit of normal leukocyte a-Gal A activity, a-Gal A sequencing...... in two expert laboratories did not identify a confirmatory mutation, presenting a diagnostic dilemma. A renal biopsy proved diagnostic and renewed efforts to detect an a-Gal A mutation. Subsequent gene dosage analyses identified a large a-Gal A deletion confirming her heterozygosity, and she was started...

  19. Role of MRI in detecting involvement of the uterine internal os in uterine cervical cancer: Systematic review of diagnostic test accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Boer, Peter de, E-mail: p.deboer@amc.uva.nl [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Adam, Judit A. [Department of Radiology, AMC, UvA (Netherlands); Department of Nuclear Medicine, AMC, UvA (Netherlands); Buist, Marrije R. [Department of Gynaecology and Obstetrics, AMC, UvA (Netherlands); Vijver, Marc J. van de [Department of Pathology, AMC, UvA (Netherlands); Rasch, Coen R. [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Stoker, Jaap; Bipat, Shandra [Department of Radiology, AMC, UvA (Netherlands); Stalpers, Lukas J.A. [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2013-09-15

    Purpose: In patients with uterine cervical cancer, pretreatment recognition of uterine extension is crucial in treatment decision-making for fertility-sparing surgery and for target delineation in radiotherapy. Although MRI is generally considered the most reliable method, its value for detecting involvement of the uterine internal os is unclear. Methods: Medline, Embase and Cochrane databases were systematically searched (January 1997–December 2012) for MRI studies that measured the accuracy of involvement of the uterine internal os compared to histopathology as reference standard in patients with uterine cervical cancer. Data were assessed using the QUADAS tool. Accuracy concerned either involvement (yes/no) of the uterine internal os, or measuring invasion distance toward the uterine corpus. Results: Two retrospective and two prospective studies described 366 patients diagnosed with uterine cervical cancer FIGO stage IIB or below, in whom 64 (17%) had uterine internal os involvement. For three studies the summary estimates of specificity, sensitivity, negative predictive value (NPV), positive predictive value (PPV), and accuracy were 91%, 97%, 99%, 79% and 95%, respectively; one study had an area under the curve (AUC) of 0.8. Conclusion: MRI has a high level of accuracy; however, data are limited and for validation a large prospective study is needed that compares actual measurements on MRI with histopathological examination.

  20. Effects of the composition and crystal structure of zinc-nickel alloy deposits on the internal strain

    Energy Technology Data Exchange (ETDEWEB)

    Tsuru, Y.; Tanaka, M. [Kyushu Inst. of Technology, Kitakyushu (Japan). Faculty of Engineering

    1996-02-05

    An average internal strain in the electrodeposited Zn-Ni alloy films was in-situ measured using the resistance wire type strain gauge setup on the reverse side of the copper substrate. The Ni content of the Zn-Ni alloy coatings utilized for the steel frame of automobiles and for the plastic coated steel sheets is around at 15% and the dominant structure is the {gamma}-phase. Such Zn-Ni alloy coatings are favorable for the protection of steel against corrosion. The internal stress in these deposits is always compressive during electroplating. However, upon turning off the current, the internal stress sharply changes from compressive to tensile. The tensile stress seems to simultaneously result in many cracks on the surface of the deposits. In this study, a resistance wire type strain gauge meter was used for successive measurement of the internal strain in the deposits during electroplating and solid-state stripping voltammetry was applied for the anodic dissolution of the deposits. And the effects concerning the partial electroleaching of Zn from the deposits on the internal strain in the deposits under periodic reverse plating. 15 refs., 8 figs., 3 tabs.

  1. Validity of premature ejaculation diagnostic tool and its association with International Index of Erectile Function-15 in Chinese men with evidence-based-defined premature ejaculation

    Directory of Open Access Journals (Sweden)

    Dong-Dong Tang

    2018-01-01

    Full Text Available The premature ejaculation diagnostic tool (PEDT is a brief diagnostic measure to assess premature ejaculation (PE. However, there is insufficient evidence regarding its validity in the new evidence-based-defined PE. This study was performed to evaluate the validity of PEDT and its association with IIEF-15 in different types of evidence-based-defined PE. From June 2015 to January 2016, a total of 260 men complaining of PE and defined as lifelong PE (LPE/acquired PE (APE according to the evidence-based definition from Andrology Clinic of the First Affiliated Hospital of Anhui Medical University, along with 104 male healthy controls without PE from a medical examination center, were enrolled in this study. All individuals completed questionnaires including demographics, medical and sexual history, as well as PEDT and IIEF-15. After statistical analysis, it was found that men with PE reported higher PEDT scores (14.28 ± 3.05 and lower IIEF-15 (41.26 ± 8.20 than men without PE (PEDT: 5.32 ± 3.42, IIEF-15: 52.66 ± 6.86, P < 0.001 for both. It was suggested that a score of ≥9 indicated PE in both LPE and APE by sensitivity and specificity analyses (sensitivity: 0.875, 0.913; specificity: 0.865, 0.865, respectively. In addition, IIEF-15 were higher in men with LPE (42.64 ± 8.11 than APE (39.43 ± 7.84, P < 0.001. After adjusting for age, IIEF-15 was negatively related to PEDT in men with LPE (adjust r = −0.225, P < 0.001 and APE (adjust r = −0.378, P < 0.001. In this study, we concluded that PEDT was valid in the diagnosis of evidenced-based-defined PE. Furthermore, IIEF-15 was negatively related to PEDT in men with different types of PE.

  2. Diagnostic standards for dopaminergic augmentation of restless legs syndrome: report from a World Association of Sleep Medicine-International Restless Legs Syndrome Study Group consensus conference at the Max Planck Institute.

    Science.gov (United States)

    García-Borreguero, Diego; Allen, Richard P; Kohnen, Ralf; Högl, Birgit; Trenkwalder, Claudia; Oertel, Wolfgang; Hening, Wayne A; Paulus, Walter; Rye, David; Walters, Arthur; Winkelmann, Juliane; Earley, Christopher J

    2007-08-01

    Augmentation of symptom severity is the main complication of dopaminergic treatment of restless legs syndrome (RLS). The current article reports on the considerations of augmentation that were made during a European Restless Legs Syndrome Study Group (EURLSSG)-sponsored Consensus Conference in April 2006 at the Max Planck Institute (MPI) in Munich, Germany, the conclusions of which were endorsed by the International RLS Study Group (IRLSSG) and the World Association of Sleep Medicine (WASM). The Consensus Conference sought to develop a better understanding of augmentation and generate a better operational definition for its clinical identification. Current concepts of the pathophysiology, clinical features, and therapy of RLS augmentation were evaluated by subgroups who presented a summary of their findings for general consideration and discussion. Recent data indicating sensitivity and specificity of augmentation features for identification of augmentation were also evaluated. The diagnostic criteria of augmentation developed at the National Institutes of Health (NIH) conference in 2002 were reviewed in light of current data and theoretical understanding of augmentation. The diagnostic value and criteria for each of the accepted features of augmentation were considered by the group. A consensus was then developed for a revised statement of the diagnostic criteria for augmentation. Five major diagnostic features of augmentation were identified: usual time of RLS symptom onset each day, number of body parts with RLS symptoms, latency to symptoms at rest, severity of the symptoms when they occur, and effects of dopaminergic medication on symptoms. The quantitative data available relating the time of RLS onset and the presence of other features indicated optimal augmentation criteria of either a 4-h advance in usual starting time for RLS symptoms or a combination of the occurrence of other features. A paradoxical response to changes in medication dose also indicates

  3. Use of SiCf/SiC ceramic composites as structure material of a fusion reactor toroid internal components

    International Nuclear Information System (INIS)

    Aiello, G.

    2001-01-01

    The use of low neutron-induced activation structural materials seems necessary in order to improve safety in future fusion power reactors. Among them, SiC f /SiC composites appear as a very promising solution because of their low activation characteristics coupled with excellent mechanical properties at high temperatures. With the main objective of evaluating the limit of present-day composites, a tritium breeding blanket using SiC f /SiC as structural material (the TAURO blanket) has been developed in the last years by the Commissariat a l'Energie Atomique (CEA). The purpose of this thesis was to modify the available design tools (computer codes, design criteria), normally used for the analyses of metallic structures, in order to better take into account the mechanical behaviour of SiC f /SiC. Alter a preliminary improvement of the calculation methods, two main topics of study could be identified: the modelling of the mechanical behaviour of the composite and the assessment of appropriate design criteria. The different behavioural models available in literature were analysed in order to find the one that was the best suited to the specific problems met in the field of fusion power. The selected model was then implemented in the finite elements code CASTEM 2000 used within the CEA for the thermo-mechanical analyses of the TAURO blanket. For the design of the blanket, we proposed a new resistance criterion whose main advantage, with respect to the other examined, lies in the easiness of identification. The suggested solutions were then applied in the design studies of the TAURO blanket. We then could show that the use of appropriate calculation methodologies is necessary in order to achieve a correct design of the blanket and a more realistic estimate of the limits of present day composites. The obtained results can also be extended to all nuclear components making use of SiC f /SiC structures. (author) [fr

  4. A Geant4-based Simulation to Evaluate the Feasibility of Using Nuclear Resonance Fluorescence (NRF) in Determining Atomic Compositions of Body Tissue in Cancer Diagnostics and Irradiation

    Science.gov (United States)

    Gilbo, Yekaterina; Wijesooriya, Krishni; Liyanage, Nilanga

    2017-01-01

    Customarily applied in homeland security for identifying concealed explosives and chemical weapons, NRF (Nuclear Resonance Fluorescence) may have high potential in determining atomic compositions of body tissue. High energy photons incident on a target excite the target nuclei causing characteristic re-emission of resonance photons. As the nuclei of each isotope have well-defined excitation energies, NRF uniquely indicates the isotopic content of the target. NRF radiation corresponding to nuclear isotopes present in the human body is emitted during radiotherapy based on Bremsstrahlung photons generated in a linear electron accelerator. We have developed a Geant4 simulation in order to help assess NRF capabilities in detecting, mapping, and characterizing tumors. We have imported a digital phantom into the simulation using anatomical data linked to known chemical compositions of various tissues. Work is ongoing to implement the University of Virginia's cancer center treatment setup and patient geometry, and to collect and analyze the simulation's physics quantities to evaluate the potential of NRF for medical imaging applications. Preliminary results will be presented.

  5. Endodontic treatment of a maxillary lateral incisor with a perforating internal resorption by using cone beam computed tomography as a diagnostic aid: a case report.

    Science.gov (United States)

    Takita, Toshiya; Tsurumachi, Tamotsu; Ogiso, Bunnai

    2011-10-01

    This case report presents the endodontic treatment of a maxillary right lateral incisor with a perforating internal resorption in a 50-year-old woman. Radiographically, internal resorption appears as a fairly uniform, radiolucent enlargement of the pulp canal and distortion of the original root canal outline. The use of cone beam computed tomography can help the clinician in making a confirmatory diagnosis and determining the treatment plan before undertaking the actual treatment. After cleaning the root canal space and the resorptive defect by mechanic instrumentation, irrigation, and interim calcium hydroxide dressing, the apical third canal was filled with a gutta-percha point by lateral condensation. The resorptive defect was filled with mineral trioxide aggregate. Follow-up radiographs at 3 years showed adequate repair of the resorption, and the tooth remained asymptomatic.

  6. Nanodevices in diagnostics

    Science.gov (United States)

    Hu, Ye; Fine, Daniel H.; Tasciotti, Ennio; Bouamrani, Ali; Ferrari, Mauro

    2010-01-01

    The real-time, personalized and highly sensitive early-stage diagnosis of disease remains an important challenge in modern medicine. With the ability to interact with matter at the nanoscale, the development of nanotechnology architectures and materials could potentially extend subcellular and molecular detection beyond the limits of conventional diagnostic modalities. At the very least, nanotechnology should be able to dramatically accelerate biomarker discovery, as well as facilitate disease monitoring, especially of maladies presenting a high degree of molecular and compositional heterogeneity. This article gives an overview of several of the most promising nanodevices and nanomaterials along with their applications in clinical practice. Significant work to adapt nanoscale materials and devices to clinical applications involving large interdisciplinary collaborations is already underway with the potential for nanotechnology to become an important enabling diagnostic technology. PMID:20229595

  7. Vibration characteristics of functionally graded carbon nanotube reinforced composite rectangular plates on Pasternak foundation with arbitrary boundary conditions and internal line supports

    Science.gov (United States)

    Zhong, Rui; Wang, Qingshan; Tang, Jinyuan; Shuai, Cijun; Liang, Qian

    2018-02-01

    This paper presents the first known vibration characteristics of moderately thick functionally graded carbon nanotube reinforced composite rectangular plates on Pasternak foundation with arbitrary boundary conditions and internal line supports on the basis of the firstorder shear deformation theory. Different distributions of single walled carbon nanotubes (SWCNTs) along the thickness are considered. Uniform and other three kinds of functionally graded distributions of carbon nanotubes along the thickness direction of plates are studied. The solutions carried out using an enhanced Ritz method mainly include the following three points: Firstly, create the Lagrange energy function by the energy principle; Secondly, as the main innovation point, the modified Fourier series are chosen as the basic functions of the admissible functions of the plates to eliminate all the relevant discontinuities of the displacements and their derivatives at the edges; Lastly, solve the natural frequencies as well as the associated mode shapes by means of the Ritz-variational energy method. In this study, the influences of the volume fraction of CNTs, distribution type of CNTs, boundary restrain parameters, location of the internal line supports, foundation coefficients on the natural frequencies and mode shapes of the FG-CNT reinforced composite rectangular plates are presented.

  8. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S.; Nagayama, Y.; Peterson, B.J.

    2003-01-01

    Standard diagnostics for fundamental plasma parameters and for plasma physics are routinely utilized for daily operation and physics study in the large helical device (LHD) with high reliability. Diagnostics for steady state plasma are intensively developed, especially for T e , n e (YAG laser Thomson, CO 2 laser polarimeter), data acquisition in steady state, heat resistant probes. To clarify the plasma property of the helical structure, 2-D or 3-D diagnostics are intensively developed: Tangential cameras (Fast SX TV, Photon counting CCD, H α TV); Tomography (Tangential SX CCD, Bolometer); Imaging (Bolometer, ECE, Reflectometer). Divertor and edge physics are one of important key issues for steady state operation. Diagnostics for neutral flux (H α array, Zeeman spectroscopy) and n e (Fast scanning probe, Li beam probe, Pulsed radar reflectometer). In addition to these, advanced diagnostics are being intensively developed with national and international collaborations in LHD. (author)

  9. Using laser absorption spectroscopy to monitor composition and physical properties of metal vapors

    International Nuclear Information System (INIS)

    Berzins, L.V.

    1993-01-01

    The Atomic Vapor Laser Isotope Separation (AVLIS) program has been using laser absorption spectroscopy to monitor vapor densities for over 15 years. Laser absorption spectroscopy has proven itself to be an accurate and reliable method to monitor both density and composition. During this time the diagnostic has moved from a research tool toward a robust component of a process control system. The hardware used for this diagnostic is discussed elsewhere at this symposium. This paper describes how the laser absorption spectroscopy diagnostic is used as a component of a process control system as well as supplying detailed measurements on vapor densities, composition, flow velocity, internal and kinetic temperatures, and constituent distributions. Examples will be drawn from the uranium AVLIS program. In addition potential applications such as composition control in the production of metal matrix composites or aircraft alloys will be discussed

  10. Short-term diagnostic stability of probable headache disorders based on the International Classification of Headache Disorders, 3rd edition beta version, in first-visit patients: a multicenter follow-up study.

    Science.gov (United States)

    Kim, Byung-Su; Moon, Heui-Soo; Sohn, Jong-Hee; Cha, Myong-Jin; Song, Tae-Jin; Kim, Jae-Moon; Park, Jeong Wook; Park, Kwang-Yeol; Cho, Soo-Jin; Kim, Soo-Kyoung

    2016-01-01

    A "Probable headache disorder" is diagnosed when a patient's headache fulfills all but one criterion of a headache disorder in the 3rd beta edition of the International Classification of Headache Disorder (ICHD-3β). We investigated diagnostic changes in probable headache disorders in first-visit patients after at least 3 months of follow-up. This was a longitudinal study using a prospective headache registry from nine headache clinics of referral hospitals. The diagnostic change of probable headache disorders at baseline was assessed at least 3 months after the initial visit using ICHD-3β. Of 216 patients with probable headache disorders at baseline, the initial probable diagnosis remained unchanged for 162 (75.0 %) patients, while it progressed to a definite diagnosis within the same headache subtype for 45 (20.8 %) by fulfilling the criteria during a median follow-up period of 6.5 months. Significant difference on the proportions of constant diagnosis was not found between headache subtypes (P headache (TTH), and 76.0 % for probable other primary headache disorders (OPHD). Among patients with headache recurrence, the proportion of constant diagnosis was higher for probable migraine than for probable TTH plus probable OPHD (59.2 vs. 23.1 %; P 3 and ≤ 6 months vs. > 6 and ≤ 10 months) in probable migraine, probable TTH, and probable OPHD, respectively. In this study, a probable headache diagnosis, based on ICHD-3β, remained in approximately three-quarters of the outpatients; however, diagnostic stability could differ by headache recurrence and subtype. Probable headache management might have to consider these differences.

  11. Using noise diagnostics for detection and monitoring of vibrations of RPV internals, and for cause analysis in Eastern German NPP with WWER-440/230 type reactors of the Russian design type

    International Nuclear Information System (INIS)

    Schumann, P.

    2000-10-01

    The report explains in detail applications and results of noise diagnostic measurements for examining vibrations which caused damage to reactor pressure vessel internals. The vibrations investigated were observed in 1975 and 1985 at the WWER-440/230 type reactors of the Russian design installed in units 1 and 2 of the Greifswald nuclear power plant, and were identified as dominant control element vibrations and abnormal core basket movements. The report presents essential operating characteristics recorded during disturbed reactor operation, the inspection results, and characteristic experimental findings from noise signal analyses and special tests examining the physical aspects of the vibration processes and their causes. Some recommendations have been derived relating to monitoring and minimization of such vibrations. (orig./CB) [de

  12. Species composition of the international shark fin trade assessed through a retail-market survey in Hong Kong.

    Science.gov (United States)

    Fields, Andrew T; Fischer, Gunter A; Shea, Stanley K H; Zhang, Huarong; Abercrombie, Debra L; Feldheim, Kevin A; Babcock, Elizabeth A; Chapman, Demian D

    2018-04-01

    The shark fin trade is a major driver of shark exploitation in fisheries all over the world, most of which are not managed on a species-specific basis. Species-specific trade information highlights taxa of particular concern and can be used to assess the efficacy of management measures and anticipate emerging threats. The species composition of the Hong Kong Special Administrative Region of China, one of the world's largest fin trading hubs, was partially assessed in 1999-2001. We randomly selected and genetically identified fin trimmings (n = 4800), produced during fin processing, from the retail market of Hong Kong in 2014-2015 to assess contemporary species composition of the fin trade. We used nonparametric species estimators to determine that at least 76 species of sharks, batoids, and chimaeras supplied the fin trade and a Bayesian model to determine their relative proportion in the market. The diversity of traded species suggests species substitution could mask depletion of vulnerable species; one-third of identified species are threatened with extinction. The Bayesian model suggested that 8 species each comprised >1% of the fin trimmings (34.1-64.2% for blue [Prionace glauca], 0.2-1.2% for bull [Carcharhinus leucas] and shortfin mako [Isurus oxyrinchus]); thus, trade was skewed to a few globally distributed species. Several other coastal sharks, batoids, and chimaeras are in the trade but poorly managed. Fewer than 10 of the species we modeled have sustainably managed fisheries anywhere in their range, and the most common species in trade, the blue shark, was not among them. Our study and approach serve as a baseline to track changes in composition of species in the fin trade over time to better understand patterns of exploitation and assess the effects of emerging management actions for these animals. © 2017 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.

  13. International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST); Volume 1: Cases E100-E200

    Energy Technology Data Exchange (ETDEWEB)

    Neymark, J.; Judkoff, R.

    2002-01-01

    This report describes the Building Energy Simulation Test for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST) project conducted by the Tool Evaluation and Improvement International Energy Agency (IEA) Experts Group. The group was composed of experts from the Solar Heating and Cooling (SHC) Programme, Task 22, Subtask A. The current test cases, E100-E200, represent the beginning of work on mechanical equipment test cases; additional cases that would expand the current test suite have been proposed for future development.

  14. International Symposium on Special Topics in Chemical Propulsion (3rd): Non-Intrusive Combustion Diagnostics Held in Scheveningen, Netherlands on 10-14 May 93

    Science.gov (United States)

    1993-05-14

    Gakuen-cho, Sakai Osaka 593 JAPAN K. Miyoshi Mazda Motor Corporation Fuchu-cho, Hiroshima 730-91 JAPAN M. Tsue Department of Mechanic Engineering...E. Kiishnan, A. J. Kurian, S. S. Rao and K N. Ninon 82 2:10 Method to Derive Solid Propellant Erosive Burning Rate Using Reactive Motor Pressure...Solid Propellant Strand In 2-D Motor by Means of Laser Scanning Device, S. Chen and J. Huang 186 PP-3.6 Influence of Internal Refractive Index

  15. Pushing the Quality Level in Networked News Business: Semantic-Based Content Retrieval and Composition in International News Publishing

    OpenAIRE

    M.W. Schranz

    2006-01-01

    Electronic publishing exploits numerous possibilities to present or exchange information and to communicate via most current media like the Internet. By utilizing modern Web technologies like Web Services, loosely coupled services, and peer-to-peer networks we describe the integration of an intelligent business news presentation and distribution network. Employing semantics technologies enables the coupling of multinational and multilingual business news data on a scaleable international leve...

  16. Influence of the alloy composition on the oxidation and internal-nitridation behaviour of nickel-base superalloys

    International Nuclear Information System (INIS)

    Krupp, U.; Christ, H.-J.

    1999-01-01

    Internal nitridation of nickel-base superalloys takes place as a consequence of the failure of protecting oxide scales (Al 2 O 3 and Cr 2 O 3 , respectively) and leads to a deterioration of the material properties due to near-surface embrittlement caused by the nitrides precipitated (TiN and AlN, respectively) and due to near-surface dissolution of the γ' phase. By using thermogravimetric methods in a temperature range between 800 C and 1100 C supplemented by microstructural examinations, the failure potential due to internal nitridation could be documented. A quantification was carried out by extending the experimental program to thermogravimetric studies in a nearly oxygen-free nitrogen atmosphere which was also applied to various model alloys of the system Ni-Cr-Al-Ti. It could be shown that the nitrogen diffusivity and solubility in nickel-base alloys is influenced particularly by the chromium concentration. An increasing chromium content leads to an enhanced internal-nitridation attack. (orig.)

  17. Synchrotron X-ray diffraction measurements of internal stresses during loading of steel-based metal matrix composites reinforced with TiB2 particles

    International Nuclear Information System (INIS)

    Bacon, D.H.; Edwards, L.; Moffatt, J.E.; Fitzpatrick, M.E.

    2011-01-01

    Highlights: → Synchrotron X-ray diffraction was used to measure internal stresses in Fe-TiB 2 MMCs. → Samples of the MMCs were loaded to failure in situ in the X-ray beam. → The results show good elastic load transfer from the matrix to the reinforcement. → There is good agreement with the predicted elastic stresses from Eshelby modeling. → During plastic deformation there is increasing load transfer to the reinforcement. - Abstract: High-energy synchrotron X-ray diffraction was used to measure the internal strain evolution in the matrix and reinforcement of steel-based metal matrix composites reinforced with particulate titanium diboride (TiB 2 ). Two systems were studied: a 316L matrix with 25% TiB 2 by volume and a W1.4418 matrix with 10% reinforcement. In situ loading experiments were performed, where the materials were loaded uniaxially in the X-ray beam. The results show the strain partitioning between the phases in the elastic regime, and the evolution of the strain partitioning once plasticity occurs. The results are compared with results from Eshelby modelling, and very good agreement is seen between the measured and modelled response for elastic loading of the material. Heat treatment of the 316-based material did not affect the elastic internal strain response.

  18. International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST): Volume 2: Cases E300-E545.

    Energy Technology Data Exchange (ETDEWEB)

    Neymark J.; Judkoff, R.

    2004-12-01

    This report documents an additional set of mechanical system test cases that are planned for inclusion in ANSI/ASHRAE STANDARD 140. The cases test a program's modeling capabilities on the working-fluid side of the coil, but in an hourly dynamic context over an expanded range of performance conditions. These cases help to scale the significance of disagreements that are less obvious in the steady-state cases. The report is Vol. 2 of HVAC BESTEST Volume 1. Volume 1 was limited to steady-state test cases that could be solved with analytical solutions. Volume 2 includes hourly dynamic effects, and other cases that cannot be solved analytically. NREL conducted this work in collaboration with the Tool Evaluation and Improvement Experts Group under the International Energy Agency (IEA) Solar Heating and Cooling Programme Task 22.

  19. Free Vibrations of Uniform Pipes Made From Composite Materials at an Internal Flow Under Effect of Additional Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Nawal H. Al – Raheimy

    2016-09-01

    Full Text Available In this paper the approximate method of Raleigh method can be used to study the effect of additional boundary conditions (clamped – free & clamped – clamped on the free transverse vibrations of uniform pipes which have length, L (1m , inner radius, "Ri" (1cm & thickness, "t" (1mm made from composite materials, where the resin of unsaturated polyester represented the matrix material reinforced by aligned (E-fibers glass in the first case and used aligned fiber (Kevlar-49 in the second case. The length of fibers is in the two types, the first type is long fibers (continuous and the second is short fibers (discontinuous for different length all at volume fraction of fibers, "f" (0.15 & 0.25. At any construction of the pipe in composite material the natural frequency decreased when the velocity of flow increased from zero to critical velocity also can be observed the pipe at clamped – clamped boundary conditions predicts natural frequency & critical velocity greater than that pipe at clamped – free. The natural frequency and critical velocity increase with increasing volume fraction and length of discontinuous fiber. The value of natural frequency for pipes which have continuous fibers is constant at certain velocity of flow while are variable in pipes which have discontinuous fibers according to ratio between length of short fiber to critical length of discontinuous fiber whereas the natural frequency increase with increasing this ratio. Finally the pipes with Kevlar fiber have high critical velocity and natural frequency compare with pipes for fiber glass.

  20. Lumbar internal disc derangement in patients with chronic low back pain: diagnostic value of the MR imaging findings as compared with provoked discography as the standard

    International Nuclear Information System (INIS)

    Park, Hyeon Seon; Park, Jee Young; Lee, Sang Ho; Ahn, Yong; Lee, Sang Yeun

    2006-01-01

    The aim of this study was to evaluate the diagnostic value of the MR imaging findings with provoked discography used as the standard for painful lumbar disc derangement. Two hundred patients (412 discs), (age rang: 21-77 year), with chronic low back pain underwent MRI and provoked discography. We evaluated the MRI T2-WI findings such as disc degeneration, high-Intensity zones and endplate abnormalities. Subsequently, provocative discography was independently performed with using MR imaging, and a painful disc was defined when moderate to severe and concordant pain was provoked. We calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the MRI findings with using provoked discography as the standard. 400 discs showed abnormal findings such as disc degeneration, HIZ and endplate abnormalities on the T2-WI images. 12 discs showed normal finding. HIZ or endplate abnormalities were always combined with disc degeneration. The prevalence of each findings were disc degeneration (400 discs: 97.1%), HIZ (111 discs: 26.9%), type I endplate abnormalities (34 discs: 8.3%), type II endplate abnormalities (75 discs: 18.2%), the combined findings of HIZ and type I endplate abnormalities (2 discs: 0.5%) and the combined findings of HIZ and type II endplate abnormalities (7 discs: 1.7%). The disc degeneration showed high sensitivity (99.5%) and low specificity (5.0%), so only the NPV (91.7%) was significant, and not the PPV (47.8%). Each findings of HIZ (sensitivity, 36.5%, specificity, 81.4%; PPV, 63.18%; NPV, 59.5%), type I endplate abnormalities (11.0%, 94.1%, 61.8% and 54.8%, respectively), type II endplate abnormalities (19.8%, 83.2%, 50.7% and 54.3%, respectively), the combined findings of HIZ and type I endplate abnormalities (0.5%, 99.6%, 50.0% and 53.4%, respectively) and the combined findings of HIZ and type II endplate abnormalities (26.0%, 99.1%, 71.4% and 53.8%, respectively) show high specificity, but low

  1. Lumbar internal disc derangement in patients with chronic low back pain: diagnostic value of the MR imaging findings as compared with provoked discography as the standard

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyeon Seon; Park, Jee Young; Lee, Sang Ho; Ahn, Yong [Wooridul spine Hospital, Seoul (Korea, Republic of); Lee, Sang Yeun [Puchon Daesung Hospital, Puchon (Korea, Republic of)

    2006-04-15

    The aim of this study was to evaluate the diagnostic value of the MR imaging findings with provoked discography used as the standard for painful lumbar disc derangement. Two hundred patients (412 discs), (age rang: 21-77 year), with chronic low back pain underwent MRI and provoked discography. We evaluated the MRI T2-WI findings such as disc degeneration, high-Intensity zones and endplate abnormalities. Subsequently, provocative discography was independently performed with using MR imaging, and a painful disc was defined when moderate to severe and concordant pain was provoked. We calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the MRI findings with using provoked discography as the standard. 400 discs showed abnormal findings such as disc degeneration, HIZ and endplate abnormalities on the T2-WI images. 12 discs showed normal finding. HIZ or endplate abnormalities were always combined with disc degeneration. The prevalence of each findings were disc degeneration (400 discs: 97.1%), HIZ (111 discs: 26.9%), type I endplate abnormalities (34 discs: 8.3%), type II endplate abnormalities (75 discs: 18.2%), the combined findings of HIZ and type I endplate abnormalities (2 discs: 0.5%) and the combined findings of HIZ and type II endplate abnormalities (7 discs: 1.7%). The disc degeneration showed high sensitivity (99.5%) and low specificity (5.0%), so only the NPV (91.7%) was significant, and not the PPV (47.8%). Each findings of HIZ (sensitivity, 36.5%, specificity, 81.4%; PPV, 63.18%; NPV, 59.5%), type I endplate abnormalities (11.0%, 94.1%, 61.8% and 54.8%, respectively), type II endplate abnormalities (19.8%, 83.2%, 50.7% and 54.3%, respectively), the combined findings of HIZ and type I endplate abnormalities (0.5%, 99.6%, 50.0% and 53.4%, respectively) and the combined findings of HIZ and type II endplate abnormalities (26.0%, 99.1%, 71.4% and 53.8%, respectively) show high specificity, but low

  2. Development of advanced material composites for use as internal insulation for LH2 tanks (gas layer concept)

    Science.gov (United States)

    Gille, J. P.

    1972-01-01

    A program is described that was conducted to develop an internal insulation system for potential application to the liquid hydrogen tanks of a reusable booster, where the tanks would be subjected to repeated high temperatures. The design of the internal insulation is based on a unique gas layer concept, in which capillary or surface tension effects are used to maintain a stable gas layer, within a cellular core structure, between the tank wall and the contained liquid hydrogen. Specific objectives were to select materials for insulation systems that would be compatible with wall temperatures of 350 F and 650 F during reentry into the earth's atmosphere, and to fabricate and test insulation systems under conditions simulating the operating environment. A materials test program was conducted to evaluate the properties of candidate materials at elevated temperatures and at the temperature of liquid hydrogen, and to determine the compatibility of the materials with a hydrogen atmosphere at the appropriate elevated temperature. The materials that were finally selected included Kapton polyimide films, silicone adhesives, fiber glass batting, and in the case of the 350 F system, Teflon film.

  3. Composite Materials

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    This book deals with the mechanical and physical behavior of composites as influenced by composite geometry. "Composite Materials" provides a comprehensive introduction for researchers and students to modern composite materials research with a special emphasis on the significance of phase geometry......, viscoelastic behavior, and internal stress states. Other physical properties considered are thermal and electrical conductivities, diffusion coefficients, dielectric constants and magnetic permeability. Special attention is given to the effect of pore shape on the mechanical and physical behavior of porous....... The book enables the reader to a better understanding of the behavior of natural composites, improvement of such materials, and design of new materials with prescribed properties. A number of examples are presented: Special composite properties considered are stiffness, shrinkage, hygro-thermal behavior...

  4. Thyroid diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Scriba, P C; Boerner, W; Emrich, S; Gutekunst, R; Herrmann, J; Horn, K; Klett, M; Krueskemper, H L; Pfannenstiel, P; Pickardt, C R

    1985-03-01

    None of the in-vitro and in-vivo methods listed permits on unambiguous diagnosis when applied alone, owing to the fact that similar or even identical findings are obtained for various individual parameters in different thyroid diseases. Further, especially the in-vitro tests are also subject to extrathyroidal effects which may mask the typical findings. The limited and varying specificity and sensitivity of the tests applied, as well as the falsification of results caused by the patients' idiosyncracies and the methodology, make it necessary to interpret and evaluate the in-vivo and in-vitro findings only if the clinical situation (anamnesis and physical examination) is known. For maximum diagnostic quality of the tests, the initial probability of the assumed type of thyroid disease must be increased (formulation of the clinical problem). The concepts of exclusion diagnosis and identification must be distinguished as well as the diagnosis of functional disturbances on the one hand and of thyroid diseases on the other. Both of this requires a qualified, specific and detailed anamnesis and examination procedure, and the clinical examination remains the obligatory basis of clinical diagnostics. In case of inexplicable discrepancies between the clinical manifestations and the findings obtained with specific methods, or between the findings obtained with a specific method, the patient should be referred to an expert institution, or the expert institution should be consulted.

  5. Thyroid diagnostics

    International Nuclear Information System (INIS)

    Scriba, P.C.; Boerner, W.; Emrich, S.; Gutekunst, R.; Herrmann, J.; Horn, K.; Klett, M.; Krueskemper, H.L.; Pfannenstiel, P.; Pickardt, C.R.; Reiners, C.; Reinwein, D.; Schleusener, H.

    1985-01-01

    None of the in-vitro and in-vivo methods listed permits on unambiguous diagnosis when applied alone, owing to the fact that similar or even identical findings are obtained for various individual parameters in different thyroid diseases. Further, especially the in-vitro tests are also subject to extrathyroidal effects which may mask the typical findings. The limited and varying specificity and sensitivity of the tests applied, as well as the falsification of results caused by the patients' idiosyncracies and the methodology, make it necessary to interpret and evaluate the in-vivo and in-vitro findings only if the clinical situation (anamnesis and physical examination) is known. For maximum diagnostic quality of the tests, the initial probability of the assumed type of thyroid disease must be increased (formulation of the clinical problem). The concepts of exclusion diagnosis and identification must be distinguished as well as the diagnosis of functional disturbances on the one hand and of thyroid diseases on the other. Both of this requires a qualified, specific and detailed anamnesis and examination procedure, and the clinical examination remains the obligatory basis of clinical diagnostics. In case of inexplicable discrepancies between the clinical manifestations and the findings obtained with specific methods, or between the findings obtained with a specific method, the patient should be referred to an expert institution, or the expert institution should be consulted. (orig./MG) [de

  6. Ambient diagnostics

    CERN Document Server

    Cai, Yang

    2014-01-01

    Part I. FundamentalsIntroductionWhat is Ambient Diagnostics?Diagnostic ModelsMultimedia IntelligenceCrowd SourcingSoft SensorsScience of SimplicityPersonal DiagnosesBasic AlgorithmsBasic ToolsSummaryProblemsTransformationEarly Discoveries of Heartbeat PatternsTransforms, Features, and AttributesSequential FeaturesSpatiotemporal FeaturesShape FeaturesImagery FeaturesFrequency Domain FeaturesMulti-Resolution FeaturesSummaryProblemsPattern RecognitionSimilarities and DistancesClustering MethodsClassification MethodsClassifier Accuracy MeasuresSummaryProblemsPart II. Multimedia IntelligenceSound RecognitionMicrophone AppsModern Acoustic Transducers (Microphones)Frequency Response CharacteristicsDigital Audio File FormatsHeart Sound SensingLung Sound SensingSnore MeterSpectrogram (STFT)Ambient Sound AnalysisSound RecognitionRecognizing Asthma SoundPeak ShiftFeature CompressionRegroupingNoise IssuesFuture ApplicationsSummaryProblemsColor SensorsColor SensingHuman Color VisionColor SensorsColor Matching ExperimentsC...

  7. Amino acid composition of lamb meat from the North East Bulgarian fine fleece breed and its crossbreds with Australian merino and Ile de France from internal breeding

    Directory of Open Access Journals (Sweden)

    R. Slavov

    2016-09-01

    Full Text Available Abstract. A comparative analysis of amino acid composition of lamb meat from the North East Bulgarian fine fleece breed (I gr. and its crossbreds from internal breeding with 25% heredity from the Australian merino (II gr. and Ile de France (III gr. breeds was conducted. Upon starting the experiment lambs were equal and during the experiment they were placed under similar conditions of feeding and rearing. To establish the amino acid composition of meat slaughter analyses were performed at 100 and 130 days of age. From the carcass of each slaughtered animal individual mean samples were taken. Studies were carried out in the Research Laboratory of the Faculty of Agriculture at Trakia University. As a result of the studies the following conclusions were made: ¼ Ile de France crossbreds in a sophisticated crossing have the highest total amino acid content, including essential amino acids in the meat of 100- and 130-day-old lambs, 6.87% and 7.36%, respectively. The lysine/arginine ratio, relating to protein atherogenicity, varies within narrow ranges among groups and marks slight increase with age – from 1.31-1.37 at 100 days to 1.41-1.46 at 130 days. With the increase of age in crossbreds from internal breeding total protein amino acid content grows, that being most prominent in lambs from the III group – from 41.92 to 43.49%. The values of total protein indices increase compared to the reference protein (from 117.97% to 118.22% for II group and from 116.44% to 120.80% for III group and the whole egg protein (from 89.39% to 91.92% for II group and from 90.53% to 93.93 for III group. It has been found that internal breeding of crossbreds with 25% heredity from the Ile de France breed has positive effect concerning the total amino acid content of lamb meat at 100 and 130 days of age, essential amino acid content in it and the levels of total amino acid indices. Internal breeding of crossbreds with 25% heredity from the Australian merino breed

  8. INTERNAL MILIEAU OF DAIRY COWS AT THE BEGINNING OF LACTATION AND ITS INFLUENCE ON COMPOSITION OF RAW MILK

    Directory of Open Access Journals (Sweden)

    Tušimová Eva

    2015-02-01

    Full Text Available The aim of this work was to evaluate selected blood biochemical parameters and milk composition of dairy cows at the beginning of lactation and to observe the correlations between blood and milk parameters. In total, 15 Holstein cows at the beginning of lactation were chosen. Blood and milk samples were collected. Energetic (glucose - GLU, d-beta-hydroxybutyrate - D-BHB, triglycerides - TG, nitrogenous (total proteins - TP, UREA, hepatic (aspartate aminotransferase - AST, alanine aminotransferase - ALT, gamma-glutamyltransferase - GGT, alkaline phosphatase - ALP, bilirubin - BILI, cholesterol - CHOL and mineral (sodium - Na, potassium - K, chlorides - Cl-, calcium – Ca, phosphorus – P, magnesium - Mg profiles were determined in the blood serum. Levels of lactose, fat, proteins and minerals (sodium - Na, potassium – K, calcium – Ca, phosphorus – P, magnesium - Mg were determined in milk. Most of the parameters outside physiological limits were found among mineral and hepatic profile. Levels of calcium, phosphorus and sodium were decreased in comparison to reference values. Average concentration of urea was also lower. On the other hand, increase of aspartate aminotransferase and gamma-glutamyltransferase were observed. Levels of lactose (4.82 g.100g-1, fat (4.21 g.100g-1, protein (3.14 g.100g-1 and calcium (4.82 g.l-1 in milk complied with Slovak national standard (STN 57 0529. In our study, ratio of fat to protein lower than 0.75 was observed in 13 % of cows (risk of ketosis and higher than 1.4 in 40 % (NEB. Strong negative correlation between serum cholesterol and milk fat (-0.716; P<0.01 and middle strong negative correlation between cholesterol and milk protein (-0.397; P<0.01 were observed. ALT affected negatively amount of phosphorus in milk (-0.417; P<0.001, which complied with demineralization of the organism and following restriction of liver detoxification activity. On the other hand, strong positive correlation was observed

  9. Comet 67P/Churyumov-Gerasimenko Surface Composition as a Playground for Radiative Transfer Modeling and Laboratory Measurements: an international ISSI team

    Science.gov (United States)

    Stephan, K.; Ciarniello, M.; Beck, P.; Filacchione, G.; Moroz, L.; Pilorget, C.; Pommerol, A.; Quirico, E.; Raponi, A.; Schröder, S.; Kappel, D.; Vinogradoff, V.; Istiqomah, I.; Rousseau, B.

    2017-12-01

    Remote sensing observations at visible-infrared (VIS-IR) wavelengths of the nucleus of comet 67P/Churyumov-Gerasimenko performed by VIRTIS (Coradini et al., 2007) aboard the Rosetta mission have revealed a surface ubiquitously covered by low-albedo material (Capaccioni et al., 2015; Ciarniello et al., 2015), characterized by the presence of refractory and semi-volatile organics and dark opaque phases (Capaccioni et al., 2015; Quirico et al., 2016). However, a quantitative determination of the physical properties (grain size, porosity) and chemical composition of the surface regolith, from spectrophotometric analysis, is still missing. This subject will be investigated within an international team hosted by ISSI (International Space Science Institute), taking advantage of available and dedicated laboratory reflectance measurements on cometary analogue samples and radiative transfer models (Hapke, 2012; Shkuratov et al., 1999; Monte Carlo ray-tracing), applied to Rosetta spectrophotometric observations of the nucleus. The convergence between models and measurements will allow us to provide a thorough characterization of 67P/Churyumov-Gerasimenko surface. At the same time, the comparison of theoretical predictions with results from laboratory reflectance spectroscopy on powders of analog materials give us the possibility to constrain the capability of the models to characterize their composition (endmember abundances and mixing modalities) and physical properties. We report about the state of the art of laboratory reflectance spectroscopy and spectral modeling applied to 67P/Churyumov-Gerasimenko VIS-IR spectrum as well as preliminary results of the team activity and planned future work. Acknowledgements: the team thanks ISSI-Switzerland for the logistic and financial support.

  10. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  11. Internal damping due to dislocation movements induced by thermal expansion mismatch between matrix and particles in metal matrix composites. [Al/SiC

    Energy Technology Data Exchange (ETDEWEB)

    Girand, C.; Lormand, G.; Fougeres, R.; Vincent, A. (GEMPPM, Villeurbanne (France))

    1993-05-01

    In metal matrix composites (MMCs), the mechanical 1 of the reinforcement-matrix interface is an important parameter because it governs the load transfer from matrix to particles, from which the mechanical properties of these materials are derived. Therefore, it would be useful to set out an experimental method able to characterize the interface and the adjacent matrix behaviors. Thus, a study has been undertaken by means of internal damping (I.D.) measurements, which are well known to be very sensitive for studying irreversible displacements at the atomic scale. More especially, this investigation is based on the fact that, during cooling of MMC's, stress concentrations originating from differences in coefficients of thermal expansion (C.T.E.) of matrix and particles should induce dislocation movements in the matrix surrounding the reinforcement; that is, local microplastic strains occur. Therefore, during I.D. measurements vs temperature these movements should contribute to MMCs I.D. in a process similar to those involved around first order phase transitions in solids. The aim of this paper is to present, in the case of Al/SiC particulate composites, new developments of this approach that has previously led to promising results in the case of Al-Si alloys.

  12. SNS Diagnostics

    International Nuclear Information System (INIS)

    Shea, T.J.; Cameron, P.; Doolittle, L.; Power, J.

    2000-01-01

    The Spallation Neutron Source (SNS) Project is a collaborative effort to build the next generation neutron science facility at Oak Ridge, TN. The facility will deliver a 2 MW proton beam to a liquid mercury target. Neutrons from this target will be moderated and sent to several state-of-the-art instruments. Six national laboratories are involved in SNS construction. Berkeley (LBNL) will build the front end that produces a 2.5 MeV, 52 mA H-beam. Los Alamos (LANL) is responsible for the 1 GeV linac with a superconducting section provided by Thomas Jefferson (JLab). Brookhaven (BNL) is building the transfer lines and accumulator ring. Oak Ridge (ORNL) and Argonne (ANL) have responsibility for the target and instruments. All activities are coordinated by the SNS project office at Oak Ridge. The high beam power, a desired availability of 95%, and an aggressive commissioning schedule lead to some interesting challenges in beam diagnostics

  13. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes.

    Science.gov (United States)

    Kim, Ki-Bong; Hwang, Ho Young; Hahn, Seokyung; Kim, Jun Sung; Oh, Se Jin

    2014-09-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial was designed to evaluate the noninferiority of the saphenous vein (SV) compared with the right internal thoracic artery ([R]ITA) used as a Y-composite graft. A total of 224 patients who had undergone off-pump revascularization for multivessel coronary artery disease using the SV or RITA as a Y-composite graft based on the in situ left ITA were assigned randomly to the SV Y-composite graft (SV group, n = 112) or free RITA Y-composite graft (RITA group, n = 112). The primary endpoint was the 1-year angiographic patency rate of the second limb conduits (SV or RITA). Postoperative 1-year coronary angiograms were performed in 215 patients (SV group, 108; RITA group, 107). The overall graft patency rate was 97.4% (745 of 765) at 1 year (97.9% in the SV group vs 96.9% in the RITA group, P = .362). The primary endpoint of the study, the 1-year patency rate of the SV composite grafts, was 97.1% (238 of 245) and was noninferior to that of the RITA composite grafts (97.1% [198 of 204]) with a 95% lower confidence limit of -2.6% (P RITA composite grafts in terms of the 1-year angiographic patency rates. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  15. Generalization of international centrifugal zone growth of metal-ceramic composites. Progress report, December 1, 1975--November 30, 1976

    International Nuclear Information System (INIS)

    Sekerka, R.F.; Hartzell, R.A.

    1976-08-01

    Research conducted to develop a realistic model of Internal Centrifugal Zone Growth (ICZG) and to utilize the predictive capacities of this model to improve and extend present ICZG systems is reported. One-dimensional models for (hypothetical) infinitely large samples heated by long RF induction coils were previously developed and an S-curve instability phenomenon associated with spontaneous coupling of the RF field to materials whose electrical conductivity increases significantly with temperature was predicted. This model was extended to two dimensions to account for finite samples and coils. During the reporting period one-dimensional modeling was used in predicting additional instabilities (S shaped with a cusp) on melting which are ''piggy-back'' with the S-curve instabilities at lower temperatures. The low temperature S instability has been demonstrated for silicon; whereas, in cooperation with Oak Ridge, the predictive capacities of the modeling have been used to engineer around instabilities in the CrO 3 -Mo systems and to extend ICZG to a number of other materials

  16. Mid-cervical flame-shaped pseudo-occlusion: diagnostic performance of mid-cervical flame-shaped extracranial internal carotid artery sign on computed tomographic angiography in hyperacute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Prakkamakul, Supada; Pitakvej, Nantaporn [King Chulalongkorn Memorial Hospital the Thai Red Cross Society, Department of Radiology, Bangkok (Thailand); Dumrongpisutikul, Netsiri; Lerdlum, Sukalaya [King Chulalongkorn Memorial Hospital the Thai Red Cross Society, Department of Radiology, Bangkok (Thailand); Chulalongkorn University, Department of Radiology, Faculty of Medicine, Bangkok (Thailand)

    2017-10-15

    Flame-shaped pseudo-occlusion of the extracranial internal carotid artery (ICA) is a flow-related phenomenon that creates computed tomographic angiography (CTA) and digital subtraction angiography (DSA) findings that mimic tandem intracranial-extracranial ICA occlusion or dissection. We aim to determine the diagnostic performance of mid-cervical flame-shaped extracranial ICA sign on CTA in hyperacute ischemic stroke patients. We retrospectively included consecutive anterior circulation ischemic stroke patients presenting within 6 h of symptom onset who underwent 4D brain CTA and arterial-phase neck CTA using a 320-detector CT scanner during August 2012 to July 2015. Two blinded readers independently reviewed arterial-phase neck CTA and characterized the extracranial ICA configurations into mid-cervical flame-shaped, proximal blunt/beak-shaped, and tubular-shaped groups. 4D whole brain CTA was used as a reference standard for intracranial ICA occlusion detection. Diagnostic performance of the mid-cervical flame-shaped extracranial ICA sign and interobserver reliability were calculated. Of the 81 cases, 11 had isolated intracranial ICA occlusion, and 6 had true extracranial ICA occlusion. Mid-cervical flame-shaped extracranial ICA sign was found in 45.5% (5/11) of isolated intracranial ICA occlusions but none in the true extracranial ICA occlusion group. The sensitivity, specificity, PPV, NPV, and accuracy of the mid-cervical flame-shaped extracranial ICA sign for the detection of isolated intracranial ICA occlusion were 45.5, 100, 100, 92.1, and 92.6%, respectively. Interobserver reliability was 0.90. The mid-cervical flame-shaped extracranial ICA sign may suggest the presence of isolated intracranial ICA occlusion and allow reliable exclusion of tandem extracranial-intracranial ICA occlusion in hyperacute ischemic stroke setting. (orig.)

  17. Mid-cervical flame-shaped pseudo-occlusion: diagnostic performance of mid-cervical flame-shaped extracranial internal carotid artery sign on computed tomographic angiography in hyperacute ischemic stroke

    International Nuclear Information System (INIS)

    Prakkamakul, Supada; Pitakvej, Nantaporn; Dumrongpisutikul, Netsiri; Lerdlum, Sukalaya

    2017-01-01

    Flame-shaped pseudo-occlusion of the extracranial internal carotid artery (ICA) is a flow-related phenomenon that creates computed tomographic angiography (CTA) and digital subtraction angiography (DSA) findings that mimic tandem intracranial-extracranial ICA occlusion or dissection. We aim to determine the diagnostic performance of mid-cervical flame-shaped extracranial ICA sign on CTA in hyperacute ischemic stroke patients. We retrospectively included consecutive anterior circulation ischemic stroke patients presenting within 6 h of symptom onset who underwent 4D brain CTA and arterial-phase neck CTA using a 320-detector CT scanner during August 2012 to July 2015. Two blinded readers independently reviewed arterial-phase neck CTA and characterized the extracranial ICA configurations into mid-cervical flame-shaped, proximal blunt/beak-shaped, and tubular-shaped groups. 4D whole brain CTA was used as a reference standard for intracranial ICA occlusion detection. Diagnostic performance of the mid-cervical flame-shaped extracranial ICA sign and interobserver reliability were calculated. Of the 81 cases, 11 had isolated intracranial ICA occlusion, and 6 had true extracranial ICA occlusion. Mid-cervical flame-shaped extracranial ICA sign was found in 45.5% (5/11) of isolated intracranial ICA occlusions but none in the true extracranial ICA occlusion group. The sensitivity, specificity, PPV, NPV, and accuracy of the mid-cervical flame-shaped extracranial ICA sign for the detection of isolated intracranial ICA occlusion were 45.5, 100, 100, 92.1, and 92.6%, respectively. Interobserver reliability was 0.90. The mid-cervical flame-shaped extracranial ICA sign may suggest the presence of isolated intracranial ICA occlusion and allow reliable exclusion of tandem extracranial-intracranial ICA occlusion in hyperacute ischemic stroke setting. (orig.)

  18. Application of Conventional and K0-Based Internal Monostandard NAA Using Reactor Neutrons for Compositional Analysis of Large Samples

    International Nuclear Information System (INIS)

    Reddy, A.V.R.; Acharya, R.; Swain, K. K.; Pujari, P.K.

    2018-01-01

    Large sample neutron activation analysis (LSNAA) work was carried out for samples of coal, uranium ore, stainless steel, ancient and new clay potteries, dross and clay pottery replica from Peru using low flux high thermalized irradiation sites. Large as well as non-standard geometry samples (1 g - 0.5 kg) were irradiated using thermal column (TC) facility of Apsara reactor as well as graphite reflector position of critical facility (CF) at Bhabha Atomic Research Centre, Mumbai. Small size (10 - 500 mg) samples were also irradiated at core position of Apsara reactor, pneumatic carrier facility (PCF) of Dhruva reactor and pneumatic fast transfer facility (PFTS) of KAMINI reactor. Irradiation positions were characterized using indium flux monitor for TC and CF whereas multi monitors were used at other positions. Radioactive assay was carried out using high resolution gamma ray spectrometry. The k0-based internal monostandard NAA (IM-NAA) method was used to determine elemental concentration ratios with respect to Na in coal and uranium ore samples, Sc in pottery samples and Fe in stainless steel. Insitu relative detection efficiency for each irradiated sample was obtained using γ rays of activation products in the required energy range. Representative sample sizes were arrived at for coal and uranium ore from the plots of La/Na ratios as a function of the mass of the sample. For stainless steel sample of SS 304L, the absolute concentrations were calculated from concentration ratios by mass balance approach since all the major elements (Fe, Cr, Ni and Mn) were amenable to NAA. Concentration ratios obtained by IM-NAA were used for provenance study of 30 clay potteries, obtained from excavated Buddhist sites of AP, India. The La to Ce concentration ratios were used for preliminary grouping and concentration ratios of 15 elements with respect to Sc were used by statistical cluster analysis for confirmation of grouping. Concentrations of Au and Ag were determined in not so

  19. Diagnostic thoracoscopy

    Directory of Open Access Journals (Sweden)

    Plavec Goran

    2002-01-01

    Full Text Available Diagnostic thoracoscopy in patients with pleural effusion of unclear origin mostly provides the correct diagnosis. Results from published reports of previous researches are not uniform. In 47 male and 20 female patients with pleural effusion of unknown etiology, after receiving negative results obtained from cytological finding of pleural effusion and percutaneous needle biopsy, thoracoscopy with biopsy of one or both pleurae was performed. Procedure was done in local anesthesia using Stortz rigid thoracoscope. In 37 patients with malignant disease (primary or metastatic diagnosis was confirmed histopathologically in 31 patient (81.12%. In 27 patients with inflammatory pleural disease diagnosis was confirmed histopathologically in 22 patients (81.4%. Among 11 patients with specific pleural effusions, tuberculosis was confirmed in 10 (90.91%. Normal finding in cases of spontaneous pneumothorax and pulmonary embolism was taken as a positive result. Total number of positive findings was 55 (82.10%. In one patient, the third spontaneous pneumothorax was the indication for thoracoscopy, and after numerous bullae were seen during the procedure, talcum powder pleurodesis was done. In four patients low intensity subcutaneous emphysema occurred one day after thoracoscopy. It can be concluded that thoracoscopy in local anesthesia out of the operating room is good and practical method for solving the unclear pleural effusions, with neglectable rate of complications.

  20. Mitigation diagnostics

    International Nuclear Information System (INIS)

    Hall, S.T.

    1990-01-01

    This paper reports that experience in the remediation of schools and other large buildings has shown the importance of the effects of both the location of geologic sources and HVAC-induced distribution of indoor radon. In general, elevated radon in areas of schools with evenly distributed HVAC pressures are correlated with maximum soil radon emanations. However, strong or unequal HVAC effects can redistribute indoor radon to areas away from the direct source. Effective remediation required a complete understanding of both contributions. In some schools, highest indoor radon levels were located near large return ducts and were attributed to proximity to negative HVAC pressure. Successful sub-slab depressurization systems were installed, however, in rooms with lower indoor but greatest sub-slab radon levels, closest to the source. This shows the inadequacy of using indoor radon levels alone as a basis for remediation. Wings of two other schools with radon problems have equivalent window fan coil units in rooms of equal size and no central HVAC system. Highest indoor radon levels correlated well with highest sub-slab radon levels due to the equivalent effects of the window units. Diagnostic tests in other schools have revealed: blockwall radon transport to upper floors; high blockwall radon adjacent to sub-slab sources; and elevated indoor radon over crawlspace being drawn upward by HVAC-induced negative pressure, determined from indoor to outdoor micromanometer measurements

  1. Insights into cerumen and application in diagnostics: past, present and future prospective.

    Science.gov (United States)

    Shokry, Engy; Filho, Nelson Roberto Antoniosi

    2017-10-15

    Cerumen or earwax is an emerging bio-fluid in clinical diagnosis that has been very little exploited during the past decades in spite of its high diagnostic potential. It is highly abundant in diagnostic biomarkers such as genetic material, lipids, proteins, chemical elements, internal and external metabolites ( e.g. hormones, volatile organic compounds, amino acids, xenobiotics etc. ) reaching earwax from the blood circulation. Thus, it is able to reflect not only physiology, pathophysiology of the human body but can also detect recent and long term exposure to environmental pollutants, without the need of invasive blood tests and in the same time overcoming many disadvantages faced by using other diagnostic biological fluids. This review discusses the biology, functions, chemistry of earwax, past and current approaches for the study of its chemical composition, emphasizing how a detected variation in its composition can offer information of high clinical value, which can be useful in diagnosis of many diseases such as metabolic disorders and tumours as well as in forensic applications. It also presents details about techniques of sample collection, storage, and analysis. Moreover, it highlights concerns about the use of earwax for diagnostic purposes, which should be addressed to make earwax diagnostics a reality in the future.

  2. Internal radiation dose in diagnostic nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Roedler, H D; Kaul, A; Hine, G J

    1978-01-01

    Absorbed dose values per unit administered activity for the most frequently used radipharmaceuticals and methods were calculated according to the MIRD concept or compiled from literature and were tabulated in conventional as well as in the SI-units recently introduced. The data are given for critical or investigated organs, ovaries, testes and red bone marrow. Where available, dose values for newborns, infants and children are included. Additionally, mean values of administered activity are listed. The manner in which to estimate the radiation dose to the patient is to multiply the tabulated dose values per unit administered activity with the corresponding mean or the actually administered activity. The methods are arranged in correlation with the following nuclear medical subspecialities: 1. Endocrinology 2. Neurology, 3. Osteomyology, 4. Gastroenterology, 5. Nephrology, 6. Pulmonology, 7. Hematology, 8. Cardiology/Angiology.

  3. Second International Diagnostic Competition - DXC'10

    Data.gov (United States)

    National Aeronautics and Space Administration — A framework to compare and evaluate diagnosis algorithms (DAs) has been created jointly by NASA Ames Research Center, Palo Alto Research Center, and Delft University...

  4. Lectures in plasma diagnostics

    International Nuclear Information System (INIS)

    Hutchinson, I.H.

    1990-06-01

    This paper discusses the following topics on plasma diagnostics: Electric probes in flowing and magnetized plasmas; Electron cyclotron emission absorption; Magnetic diagnostics; Spectroscopy; and Thomson Scattering

  5. Composition of functional ecological guilds of the fish fauna of the internal sector of the Amazon Estuary, Pará, Brazil.

    Science.gov (United States)

    Mourão, Keila R M; Ferreira, Valdimere; Lucena-Frédou, Flávia

    2014-12-01

    The present study describes the spatial and temporal structure of the estuarine fish community in the internal sector of the Amazon Estuary. Samples were obtained in the main channels and tidal creeks of Guajará and Marajó Bays and Guamá River. A total of 41,516 fish specimens were collected, representing 136 taxa, 38 families and 12 orders. In the dry season, the mean salinity of the main channel increased along a limnic-marine gradient, between the Guamá River and the Marajó Bay. Species richness was lowest in the mouth of the Guamá River and in the right margin of the Guajará Bay. Fish species composition and environmental guilds differed markedly among areas: Migrants and Freshwater Stragglers were dominant in the Guamá River and the Guajará Bay, while Estuarine, Marine Stragglers and Migrants predominated in the Marajó Bay. However, the trophic guilds were still relatively well balanced, in functional terms. Piscivores and Zoobenthivores were the dominant feeding functional groups in all the studied areas. In this study, the assessment of the community and the use of the guild approach were efficient to describe the structure and functioning of the assemblages of estuarine fish also helping to assess the anthropogenic pressures in the area.

  6. The composition of international success

    DEFF Research Database (Denmark)

    Helles, Rasmus; Lai, Signe Sophus

    features in addition to narrative and character motivations and actions (Eskjær and Helles, 2012), similar to the landmark study of the Hollywood style by Bordwell, Thompson and Staiger (1985). The paper contributes to the analysis of why series travel by taking a comparative look at all series produced...... in the same period. We show that there are systematic differences in terms of formal characteristics, narrative style, character interaction, emotions and themes between Danish drama series that travel and series that do not. Furthermore, the findings suggest that previous explanations of what makes Danish...... series travel, emphasising the distinctive Danishness of the series, need to be balanced against the characteristics of series that do not travel. The analysis suggests that character interaction in well-travelled series is characterized by a higher emphasis on the expression of emotions, whereas less...

  7. MAST magnetic diagnostics

    Science.gov (United States)

    Edlington, T.; Martin, R.; Pinfold, T.

    2001-01-01

    The mega-ampere spherical tokamak (MAST) experiment is a new, large, low aspect ratio device (R=0.7-0.8 m, a=0.5-0.65 m, maximum BT˜0.63 T at R=0.7 m) operating its first experimental physics campaign. Designed to study a wide variety of plasma shapes with up to 2 MA of plasma current with an aspect ratio down to 1.3, the poloidal field (PF) coils used for plasma formation, equilibrium and shaping are inside the main vacuum vessel. For plasma control and to investigate a wide range of plasma phenomena, an extensive set of magnetic diagnostics have been installed inside the vacuum vessel. More than 600 vacuum compatible, bakeable diagnostic coils are configured in a number of discrete arrays close to the plasma edge with about half the coils installed behind the graphite armour tiles covering the center column. The coil arrays measure the toroidal and poloidal variation in the equilibrium field and its high frequency fluctuating components. Internal coils also measure currents in the PF coils, plasma current, stored energy and induced currents in the mechanical support structures of the coils and graphite armour tiles. The latter measurements are particularly important when halo currents are induced following a plasma termination, for example, when the plasma becomes vertically unstable. The article describes the MAST magnetic diagnostic coil set and their calibration. The way in which coil signals are used to control the plasma equilibrium is described and data from the first MAST experimental campaign presented. These coil data are used as input to the code EFIT [L. Lao et al., Nucl. Fusion 25, 1611 (1985)], for measurement of halo currents in the vacuum vessel structure and for measurements of the structure of magnetic field fluctuations near the plasma edge.

  8. [Cognitive errors in diagnostic decision making].

    Science.gov (United States)

    Gäbler, Martin

    2017-10-01

    Approximately 10-15% of our diagnostic decisions are faulty and may lead to unfavorable and dangerous outcomes, which could be avoided. These diagnostic errors are mainly caused by cognitive biases in the diagnostic reasoning process.Our medical diagnostic decision-making is based on intuitive "System 1" and analytical "System 2" diagnostic decision-making and can be deviated by unconscious cognitive biases.These deviations can be positively influenced on a systemic and an individual level. For the individual, metacognition (internal withdrawal from the decision-making process) and debiasing strategies, such as verification, falsification and rule out worst-case scenarios, can lead to improved diagnostic decisions making.

  9. The impact of the International Association of Diabetes and Pregnancy Study Groups (IADPSG) fasting glucose diagnostic criterion on the prevalence and outcomes of gestational diabetes mellitus in Han Chinese women.

    Science.gov (United States)

    Liao, S; Mei, J; Song, W; Liu, Y; Tan, Y-D; Chi, S; Li, P; Chen, X; Deng, S

    2014-03-01

    The International Association of Diabetes and Pregnancy Study Groups (IADPSG) proposed that a one-time value of fasting plasma glucose of 5.1 mmol/l or over at any time of the pregnancy is sufficient to diagnose gestational diabetes. We evaluated the repercussions of the application of this threshold in pregnant Han Chinese women. This is a retrospective study of 5360 (72.3% of total) consecutively recruited pregnant Han Chinese women in one centre from 2008 to 2011. These women underwent a two-step gestational diabetes diagnostic protocol according to the previous American Diabetes Association criteria. The IADPSG fasting plasma glucose criterion was used to reclassify these 5360 women. The prevalence, clinical characteristics and obstetric outcomes were compared among the women classified as having gestational diabetes by the previous American Diabetes Association criteria (approximately 90% were treated), those reclassified as having gestational diabetes by the single IADPSG fasting plasma glucose criterion (untreated), but not as having gestational diabetes by the previous American Diabetes Association criteria, and those with normal glucose tolerance. There were 626 cases of gestational diabetes defined by the previous American Diabetes Association criteria (11.7%) and these cases were associated with increased risks of maternal and neonatal outcomes when compared with the women with normal glucose tolerance. With the IADPSG fasting plasma glucose criterion, another 1314 (24.5%) women were reclassified as having gestational diabetes. Gestational diabetes classified by the IADPSG fasting plasma glucose criterion was associated with gestational hypertension (P = 0.0094) and neonatal admission to nursery (P = 0.035) prior to adjustment for maternal age and BMI, but was no longer a predictor for adverse pregnancy outcomes after adjustment. The simple IADPSG fasting plasma glucose criterion increased the Chinese population with gestational diabetes by 200%. The

  10. Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Chopra, A. [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Grainger, A.J.; Robinson, Philip [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Dube, B.; Evans, R.; Hodgson, R. [Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Conroy, J. [Harrogate and District NHS Trust, Trauma and Orthopaedics Department, Harrogate (United Kingdom); Macdonald, D. [Chapel Allerton Hospital, Trauma and Orthopaedics Department, Leeds Teaching Hospitals, Leeds (United Kingdom)

    2018-03-15

    To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI. circle Conventional 3T MRI is equivalent to 1.5T MRA for diagnosing labral tears. (orig.)

  11. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  12. Nuclear power plant diagnostic system

    International Nuclear Information System (INIS)

    Prokop, K.; Volavy, J.

    1982-01-01

    Basic information is presented on diagnostic systems used at nuclear power plants with PWR reactors. They include systems used at the Novovoronezh nuclear power plant in the USSR, at the Nord power plant in the GDR, the system developed at the Hungarian VEIKI institute, the system used at the V-1 nuclear power plant at Jaslovske Bohunice in Czechoslovakia and systems of the Rockwell International company used in US nuclear power plants. These diagnostic systems are basically founded on monitoring vibrations and noise, loose parts, pressure pulsations, neutron noise, coolant leaks and acoustic emissions. The Rockwell International system represents a complex unit whose advantage is the on-line evaluation of signals which gives certain instructions for the given situation directly to the operator. The other described systems process signals using similar methods. Digitized signals only serve off-line computer analyses. (Z.M.)

  13. Characterization of Chemical Composition in PM2.5 in Beijing Before, During, and After a Large-Scale International Event

    Science.gov (United States)

    Yang, X.; Cheng, S.; Li, J.

    2017-12-01

    To commemorate the 70th anniversary of the victory of the Chinese people's Anti-Japanese War and the World Anti-Fascist War, an international parade was held in Beijing in September 2015. In order to ensure satisfactory air quality during this event, a phased emission control measures were taken in Beijing and its surrounding provinces. The 24-h PM2.5 samples were collected in Beijing from August 1 to September 15, 2015 covering the period before, during and after this large-scale event. The observed PM2.5 data, meteorological data, emission reduction measures, and air mass trajectory simulation results were systematically analyzed to understand the pollution characteristics and chemical compositions of PM2.5 in Beijing. The results indicated that PM2.5 concentration during the two emission control phases was reduced by 61.7% comparing to the non-control period, but the regional transport of pollutants and meteorological conditions had a more prominent impact on PM2.5 than emission reduction during phase 2. The secondary water-soluble ions including SO42-, NO3-, and NH4+ were found as the main ions present in PM2.5. During the entire emission control period, organic carbon (OC) and elemental carbon (EC) mass concentrations were decreased by 53.1% and 57.9%. A PM2.5 mass balance was analyzed, and it was found that the organic matter accounted for 29.3, 37.6 and 28.5% of the PM2.5 mass before, during and after the emission control, while the contribution of mobile sources to PM2.5 was relatively outstanding after a series of emission control measures.

  14. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  15. Evolution of the internal friction in SIC particle reinforced 8090 Al-Li metal matrix composite; Evolucion de la friccion interna del material compuesto de matriz Al-Li 8090 reforzado con particulas de SiC

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez-Urrutia, I.; Gallego, I.; No, M. L.; San Juan, J. M.

    2001-07-01

    The present study has been undertaken to investigate the mechanisms of thermal stress relief at the range of temperatures below room temperature for the metal matrix composite Al-Li 8090/SiC. For this aim the experimental technique of internal friction has been used which has been showed up very effective. Several thermal cycles from 453 K to 100 K were used in order to measures the internal friction as well as the elastic modules of the material concluding that thermal stresses are relaxed by microplastic deformation around the reinforcements. It has been also related the variation in the elastic modules with the different levels of precipitation. (Author) 18 refs.

  16. Social anxiety disorder diagnostic criteria perform equally across age, comorbid diagnosis, and performance/interaction subtypes.

    Science.gov (United States)

    Crome, Erica; Baillie, Andrew

    2015-01-01

    The prevalence of social anxiety disorder (SAD) is frequently higher in younger age groups and people with other anxiety or mood disorders; however, it is unclear whether these groups have a higher risk for developing SAD or are simply more likely to endorse diagnostic criteria than other people with similar levels of social anxiety. Explicitly testing the assumption all people respond to structured diagnostic interviews in comparable ways (measurement invariance) is essential in ensuring systematic response biases do not create spurious group differences. This research aims to systematically test whether age, comorbidity status, or types of social fears affect responses to a structured diagnostic interview. Responses from 1755 participants in a large-scale survey of mental health in Australia screening into the social phobia/SAD section of the Composite International Diagnostic Interview were used. Three series of multigroup confirmatory factor analyses for categorical data systematically tested for increasingly strict levels of measurement invariance. Overall, patterns of responding to diagnostic criteria were comparable across the groups, supporting assumptions of measurement invariance. Establishment of invariance supports the interpretation of differences between age, comorbidity status, and types of social situations feared as genuine differences in experience as opposed to measurement biases.

  17. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-01-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next

  18. Molecular diagnostic PCR handbook

    International Nuclear Information System (INIS)

    Viljoen, G.J.; Crowther, J.R.; Nel, L.H.

    2005-01-01

    The uses of nucleic acid-directed methods have increased significantly in the past five years and have made important contributions to disease control country programmes for improving national and international trade. These developments include the more routine use of PCR as a diagnostic tool in veterinary diagnostic laboratories. However, there are many problems associated with the transfer and particularly, the application of this technology. These include lack of consideration of: the establishment of quality-assured procedures, the required set-up of the laboratory and the proper training of staff. This can lead to a situation where results are not assured. This book gives a comprehensive account of the practical aspects of PCR and strong consideration is given to ensure its optimal use in a laboratory environment. This includes the setting-up of a PCR laboratory; Good Laboratory Practice and standardised PCR protocols to detect animal disease pathogens. Examples of Standard Operating Procedures as used in individual specialist laboratories and an outline of training materials necessary for PCR technology transfer are presented. The difficulties, advantages and disadvantages in PCR applications are explained and placed in context with other test systems. Emphasis is placed on the use of PCR for detection of pathogens, with a particular focus on diagnosticians and scientists from the developing world. It is hoped that this book will enable readers from various disciplines and levels of expertise to better judge the merits of PCR and to increase their skills and knowledge in order to assist in a more logical, efficient and assured use of this technology

  19. Towards diagnostics for a fusion reactor

    International Nuclear Information System (INIS)

    Costley, A. E.

    2009-01-01

    The requirements for measurements on modern tokamak fusion plasmas are outlined, and the techniques and systems used to make the measurements, usually referred to as 'diagnostics', are introduced. The basics of three particular diagnostics - magnetics, neutron systems and a laser based optical system - are outlined as examples of modern diagnostic systems, and the implementation of these diagnostics on a current tokamak (JET) are described. The next major step in magnetic confinement fusion is the construction and operation of the International Thermonuclear Experimental Reactor (ITER), which is a joint project of China, Europe, Japan, India, Korea, the Russian Federation, and the United States. Construction has begun in Cadarache, France. It is expected that ITER will operate at the 500 MW level. Because of the harsh environment in the vacuum vessel where many diagnostic components are located, the development of diagnostics for ITER is a major challenge - arguably the most difficult challenge ever undertaken in the field of diagnostics. The main elements in the diagnostic step are outlined using the three chosen techniques as examples. Finally, the step beyond ITER to a demonstration reactor, DEMO, that is expected to produce several GWs of fusion power is considered and the impact on diagnostics outlined. It is shown that the applicability and development steps needed for the individual diagnostics techniques will differ. The challenges for DEMO diagnostics are substantial and a dedicated effort should be made to find and develop new techniques, and especially techniques appropriate to the DEMO environment. It is argued that the limitations and difficulties in diagnostics should be a consideration in the optimization and designs of DEMO. (author)

  20. EDITORIAL Smart materials, multifunctional composites, and morphing structures: selected papers from the 20th International Conference on Adaptive Structures and Technologies (ICAST 2009) Smart materials, multifunctional composites, and morphing structures: selected papers from the 20th International Conference on Adaptive Structures and Technologies (ICAST 2009)

    Science.gov (United States)

    Liao, Wei-Hsin

    2010-12-01

    The 20th International Conference on Adaptive Structures and Technologies (ICAST) was held on 20-22 October 2009 in Hong Kong. This special section of Smart Materials and Structures is derived from the research papers presented at the conference. Of the 106 papers presented at the conference, 11 papers were reviewed and accepted for this special section, following the regular review procedures of the journal. This special section is focused on smart materials, multifunctional composites, and applications on morphing structures. Smart materials. Smart materials are the foundation of adaptive structures and intelligent systems. The development of new materials will lead to significant improvement in various applications. Three articles are focused on the fabrication of new materials and investigation of their behaviors: Barium strontium zirconate titanate ((Ba1-xSrx)(ZrxTi1-x)O3; BSZT, x = 0.25 and 0.75) ceramics with a highly crystalline structure were fabricated using the combustion technique. The microstructure of BSZT powders exhibited an almost-spherical morphology and had a porous agglomerated form. Polyaniline (PANI)/clay nanoparticles with unique core-shell structure were synthesized via Pickering emulsion polymerization. By dispersing PANI/clay nanoparticles in silicone oil, the ER fluid was made. Magnetic field effects were investigated on the deposition rate and surface morphology of chromium nitride coatings deposited by magnetron sputtering for superior hardness, excellent wear and oxidation resistance. The surface morphology of chromium nitride films was also examined by a scanning electron microscope (SEM). Multifunctional composites. Composites are made from two or more constituent materials so they can combine the best properties of different materials. Five papers deal with fabrication, testing, and modeling of various multifunctional composites: A new active structural fiber (ASF) was fabricated by coating a single carbon fiber with a concentric

  1. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  2. Diagnostic Algorithm Benchmarking

    Science.gov (United States)

    Poll, Scott

    2011-01-01

    A poster for the NASA Aviation Safety Program Annual Technical Meeting. It describes empirical benchmarking on diagnostic algorithms using data from the ADAPT Electrical Power System testbed and a diagnostic software framework.

  3. Veterinary Molecular Diagnostics

    NARCIS (Netherlands)

    Roest, H.I.J.; Engelsma, M.Y.; Weesendorp, E.; Bossers, A.; Elbers, A.R.W.

    2017-01-01

    In veterinary molecular diagnostics, samples originating from animals are tested. Developments in the farm animals sector and in our societal attitude towards pet animals have resulted in an increased demand for fast and reliable diagnostic techniques. Molecular diagnostics perfectly matches this

  4. Radiation exposure in diagnostic medicine

    International Nuclear Information System (INIS)

    Haehnel, S.; Michalczak, H.; Reinoehl-Kompa, S.

    1995-01-01

    This volume includes the manuscripts of the papers read at the conference as well as a summary and assessment of its results. The scientific discussions were centred upon the following issues: - International surveys and comparisons of rdiation exposures in diagnostic radiology and nuclear medicine, frequency of the individual diagnostic procedures and age distribution of patients examined; - policies and regulations for the radiation protection of patients, charcteristic dosimetric values and practical usefulness of the effective dose concept during medical examinations; - assessments of the relative benefits and risks and measures to reduce the radiation exposure in the light of quality assurance aspects. The main objective of this conference not only was to evaluate the risks from diagnostic radiology and nuclear medicine but also to encourgage a critical analysis and adjustment of examination routines followed in everyday practice. Among the measures recommended were quality assurance, maintenace of international standards, development of guidelines, introduction of standard doses, improved training and professional education of personnel as well as surveys and analyses of certain examination procedures associated with substantial radiation exposure. (orig./MG) [de

  5. PVT Degradation Studies: Acoustic Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Gerges [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smith, Philip J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-01

    Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regions with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.

  6. VITAMIN-E, LIPID FRACTIONS, AND FATTY-ACID COMPOSITION OF COLOSTRUM, TRANSITIONAL MILK, AND MATURE MILK - AN INTERNATIONAL COMPARATIVE-STUDY

    NARCIS (Netherlands)

    BOERSMA, ER; OFFRINGA, PJ; MUSKIET, FAJ; CHASE, WM; SIMMONS, IJ

    Triglycerides, cholesterol, fatty acid composition, and tocopherols were determined in colostrum, transitional milk, and mature milk in St Lucia. With progress of lactation, triglycerides and percentage medium-chain fatty acids increased whereas tocopherols, cholesterol, and percentage longchain

  7. Bayesian analysis of ion beam diagnostics

    International Nuclear Information System (INIS)

    Toussaint, U. von; Fischer, R.; Dose, V.

    2001-01-01

    Ion beam diagnostics are routinely used for quantitative analysis of the surface composition of mixture materials up to a depth of a few μm. Unfortunately, advantageous properties of the diagnostics, like high depth resolution in combination with a large penetration depth, no destruction of the surface, high sensitivity for large as well as for small atomic numbers, and high sensitivity are mutually exclusive. Among other things, this is due to the ill-conditioned inverse problem of reconstructing depth distributions of the composition elements. Robust results for depth distributions are obtained with adaptive methods in the framework of Bayesian probability theory. The method of adaptive kernels allows for distributions which contain only the significant information of the data while noise fitting is avoided. This is achieved by adaptively reducing the degrees of freedom supporting the distribution. As applications for ion beam diagnostics Rutherford backscattering spectroscopy and particle induced X-ray emission are shown

  8. SALIVA AS A DIAGNOSTIC FLUID

    Directory of Open Access Journals (Sweden)

    Pezelj-Ribarić Sonja

    2015-12-01

    Full Text Available Saliva is a readily available oral fluid with many functions, from digestion, maintenance of oral tissues' integrity, to caries prevention. Changes regarding its secretion may be divided into qualitative and quantitative: both of them are a consequence of certain conditions/diseases (e.g. internal factors or nutrients/drugs ingested (e.g. external factors. During the last 15 years, technological advances gave a significant momentum to utilization of saliva as a diagnostic tool. Analysis of saliva, just like the blood analysis, has two main objectives: to identify the subjects suffering from a certain disorder, and to follow the development and progress of therapy. This paper provides an overview of possibilities for the use of saliva for diagnostic purposes and gives specific examples of some clinical investigations, with the final aim to stimulate the use of this noninvasive means for the health care promotion.

  9. Development of new diagnostics for WEST

    International Nuclear Information System (INIS)

    Lotte, P.; Moreau, P.; Gil, C.

    2015-01-01

    WEST, the upgraded superconducting tokamak Tore Supra, will be an international experimental platform aimed to support ITER Physics program. The main objective of WEST is to provide relevant plasma conditions for validating plasma facing component (PFC) technology, in particular the actively cooled Tungsten divertor monoblocks, and also assessing high heat flux and high fluence plasma wall interactions with Tungsten in order to prepare ITER divertor operation. In parallel, WEST will also open new experimental opportunities for developing integrated H mode operation and exploring steady state scenarios in a metallic environment. In order to fulfil the Scientific Program of WEST, new diagnostics have been developed in addition to the already existing diagnostics of Tore Supra, modified and improved during the shutdown. For the PFC technology validation program, new tools have been implemented, like a full infrared survey of the PFC, a new calorimetry system, local temperature measurements (thermocouple and Bragg grating optical fiber), and several sets of Langmuir probes. For the analysis of long pulse H mode operation, new plasma diagnostics will be implemented, among which the Visible Spectroscopy diagnostic for W sources and transport studies, the Soft-Xray diagnostic based on gas electron multiplier detectors for transport and MHD studies, the X-ray imaging crystal spectroscopy diagnostic with advanced solid state detector properties for ion temperature, ion density and plasma rotation velocity measurements, and the ECE Imaging diagnostic for MHD and turbulence studies. Most of these new diagnostics are developed with the participation of French Universities or through international collaborations. This paper focuses on the description of these four plasma diagnostics. (author)

  10. Vibration diagnostics instrumentation for ILC

    Energy Technology Data Exchange (ETDEWEB)

    Bertolini, A.

    2007-06-15

    The future e{sup -}e{sup +} 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the accelerator cavities and optical components are demanded to transport and focus the high energy electron and positron beams with reasonable position jitter and low emittance. A brief review of techniques and devices evaluated and developed so far for the vibration diagnostics of the machine is presented in this paper. (orig.)

  11. Vibration diagnostics instrumentation for ILC

    International Nuclear Information System (INIS)

    Bertolini, A.

    2007-06-01

    The future e - e + 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the accelerator cavities and optical components are demanded to transport and focus the high energy electron and positron beams with reasonable position jitter and low emittance. A brief review of techniques and devices evaluated and developed so far for the vibration diagnostics of the machine is presented in this paper. (orig.)

  12. Diagnostic Development on NSTX

    International Nuclear Information System (INIS)

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-01-01

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted

  13. TFTR diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller

  14. Patterns of anaphylaxis after diagnostic workup

    DEFF Research Database (Denmark)

    Oropeza, Athamaica Ruiz; Bindslev-Jensen, Carsten; Broesby-Olsen, Sigurd

    2017-01-01

    BACKGROUND: Most published studies on anaphylaxis are retrospective or register based. Data on subsequent diagnostic work-up are sparse. We aimed to characterize patients seen with suspected anaphylaxis at the emergency care setting (ECS), after subsequent diagnostic work-up at our Allergy Center...... (AC). METHODS: Prospective study including patients from the ECS, Odense University Hospital, during May 2013-April 2014. Possible anaphylaxis cases were daily identified based on a broad search profile including history and symptoms in patient records, diagnostic codes and pharmacological treatments....... At the AC, all patients were evaluated according to international guidelines. RESULTS: Among 226 patients with suspected anaphylaxis, the diagnosis was confirmed in 124 (54.9%) after diagnostic work-up; 118 of the 124 fulfilled WAO/EAACI criteria of anaphylaxis at the ECS, while 6 were found among 46...

  15. Device for controlling the composition of the mixture burnt in the combustion spaces of an internal combustion engine. Einrichtung zur Regelung der Zusammensetzung des in den Brennraeumen einer Brennkraftmaschine zur Verbrennung kommenden Betriebsgemisches

    Energy Technology Data Exchange (ETDEWEB)

    Latsch, R; Bianchi, V

    1986-07-31

    The purpose of the invention is to create a device by which the extent of the reaction to the control of the composition of the mixture burnt in the combustion spaces of an internal combustion engine can be measured in a sensitive, responsive and safe way, where the position of the elements detecting the reaction should have a relatively small effect on the accuracy of the measurement and the extent of measurement. According to the invention, this problem is solved by the use of 2 thermal sensors connected to a control device (photo-electric diode, photo-electric transistor), one of which acts catalytically and causes the parts of the gas mixture there to react. The thermal sensor output signals are periodically integrated via the piston work and are entered in the control device. The measured temperature is a measure of how far the method of operation of the internal combustion engine has approached its limits. (HWJ).

  16. The diagnostic status of first-rank symptoms

    DEFF Research Database (Denmark)

    Nordgaard, Julie; Arnfred, Sidse Marie; Handest, P.

    2008-01-01

    In the International Statistical Classification of Diseases, Tenth Revision(ICD-10) and Diagnostic and Statistical Manual of Mental Disorder, Third and Fourth Edition(DSM-III-IV), the presence of one of Schneider "first-rank symptoms" (FRS) is symptomatically sufficient for the schizophrenia...... diagnosis. Yet, it has been claimed that FRS may also be found in the nonschizophrenic conditions, and therefore, they are not specific or diagnostic for schizophrenia. This review was made to clarify the issue of diagnostic specificity....

  17. Psychologists' diagnostic processes during a diagnostic interview

    NARCIS (Netherlands)

    Groenier, Marleen; Beerthuis, Vos R.J.; Pieters, Julius Marie; Witteman, C.L.M.; Witteman, Cilia L.M.; Swinkels, Jan A.

    2011-01-01

    In mental health care, psychologists assess clients’ complaints, analyze underlying problems, and identify causes for these problems, to make treatment decisions. We present a study on psychologists’ diagnostic processes, in which a mixed-method approach was employed. We aimed to identify a common

  18. Providing Pressurized Gasses to the International Space Station (ISS): Developing a Composite Overwrapped Pressure Vessel (COPV) for the Safe Transport of Oxygen and Nitrogen

    Science.gov (United States)

    Kezirian, Michael; Cook, Anthony; Dick, Brandon; Phoenix, S. Leigh

    2012-01-01

    To supply oxygen and nitrogen to the International Space Station, a COPV tank is being developed to meet requirements beyond that which have been flown. In order to "Ship Full' and support compatibility with a range of launch site operations, the vessel was designed for certification to International Standards (ISO) that have a different approach than current NASA certification approaches. These requirements were in addition to existing NASA certification standards had to be met. Initial risk-reduction development tests have been successful. Qualification is in progress.

  19. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  20. Ongoing experiments: diagnostics requirements

    International Nuclear Information System (INIS)

    Dickerman, C.E.

    1976-01-01

    The paper reviews the fuel motion diagnostics needs for ongoing LMFBR safety experiments over approximately the next five years, with the discussion centered on TREAT. Brief comments on the direction in which clad motion diagnostics requirements are expected to develop are also presented

  1. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  2. Gearbox vibration diagnostic analyzer

    Science.gov (United States)

    1992-01-01

    This report describes the Gearbox Vibration Diagnostic Analyzer installed in the NASA Lewis Research Center's 500 HP Helicopter Transmission Test Stand to monitor gearbox testing. The vibration of the gearbox is analyzed using diagnostic algorithms to calculate a parameter indicating damaged components.

  3. Thematic plan on diagnostic radiology

    International Nuclear Information System (INIS)

    2003-01-01

    Due to the vital importance of diagnostic radiology in both the diagnosis and management of disease processes, there is a need for a greater coherent international effort to help the developing nations create strategies for the incorporation of imaging into their healthcare systems. To meet the needs of such countries, a comprehensive programme is required to take into consideration the availability of local expertise (medical and technical), the infrastructure (stable electrical supply, water and air-conditioning) and the disease pattern or burden. In short, the total solution requires coordinating the International Atomic Energy Agency efforts with those of other partners. The Agency already has programmes in nuclear medicine and radiation therapy supported by activities in dosimetry and medical physics. Through the Technical Co-operation fund the Agency already supports projects in some areas of diagnostic imaging, dosimetry and radiation protection, but it lacks a comprehensive programme to provide a systematic approach focusing on the medical aspects of imaging science and including all the imaging technologies. Member States require the Agency's assistance in this area since no single UN organisation has the resources or the expertise to do the entire job without help. This document presents the proposed programme strategy and action plan

  4. Fiscal 1997 report on the results of the international standardization R and D. R and D of the basic evaluation method of functional composite particles; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Kinosei fukugo biryushi no kibanteki hyoka hoho no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The paper established the basic evaluation method of composite particles manifesting functions which the existing mono-componet particles do not have and aimed at the international standardization of the measuring method of them. To be concrete, the development was studied of methods to evaluate the mechanical bonding state of different composition in composite particles, the chemical bonding state of different composition and the electromagnetic state of the surface of composite particles. As a result, in the evaluation method of the mechanical bonding state of different composition in composite particles, methods to evaluate the bonding state and the large composite bonding state of the coated particle layer were developed to clarify the details to be standardized for each method. In the evaluation method of the chemical bonding state of different composition in composite particles, the electronic energy loss spectroscopy was an effective method to evaluate the chemical bonding state in composite particles of oxide ceramics. Further, in the evaluation method of the electromagnetic field of the surface of composite particles, standard experimental procedures for observing the electromagnetic field by interference of electronic waves were proposed, and the evaluation of the electromagnetic field state of composite particles used ranging from low temperature to high temperature was made possible. 41 refs., 85 figs., 14 tabs.

  5. Quality control for diagnostic oral microbiology laboratories in European countries

    NARCIS (Netherlands)

    Rautemaa-Richardson, R.; van der Reijden, W.A.; Dahlen, G.; Smith, A.J.

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB)

  6. Announcement of the Diagnostics 2016 Junior Scientists Travel Award

    OpenAIRE

    2016-01-01

    With the goal of recognizing outstanding contributions to the field of medical diagnostics by early-career investigators, including assistant professors, postdoctoral students and PhD students, and assisting them in attending international conferences in 2016, early this year Diagnostics accepted nominations for the Junior Scientists Travel Award 2016.

  7. International Trade. International Business

    OpenAIRE

    Мохнюк, А. М.; Mokhniuk, A. M.

    2015-01-01

    Work programme of the study course “International Trade. International Business” was prepared in accordance with educational and vocational training program for bachelors of training direction 6.030601 “Management”.

  8. Factors affecting initial disability allowance rates for the Disability Insurance and Supplemental Security Income programs: the role of the demographic and diagnostic composition of applicants and local labor market conditions.

    Science.gov (United States)

    Rupp, Kalman

    2012-01-01

    Various factors outside the control of decision makers may affect the rate at which disability applications are allowed or denied during the initial step of eligibility determination in the Social Security Disability Insurance (DI) and Supplemental Security Income (SSI) programs. In this article, using individual-level data on applications, I estimate the role of three important factors--the demographic characteristics of applicants, the diagnostic mix of applicants, and the local unemployment rate--in affecting the probability of an initial allowance and state allowance rates. I use a random sample of initial determinations from 1993 through 2008 and a fixed-effects multiple regression framework. The empirical results show that the demographic and diagnostic characteristics of applicants and the local unemployment rate substantially affect the initial allowance rate. An increase in the local unemployment rate tends to be associated with a decrease in the initial allowance rate. This negative relationship holds for adult DI and SSI applicants and for SSI childhood applicants.

  9. Diagnostics of the Enterprise Export Potential

    Directory of Open Access Journals (Sweden)

    Skrynkovskyy Ruslan M.

    2016-11-01

    Full Text Available The aim of the article is to form and develop theoretical and methodological foundations for diagnostics of the enterprise export potential, which should be understood as a process of identification, analysis and assessment of the level of potential possibility and readiness of the enterprise to implement export activities taking into account the impact of interrelated internal variables (goals, technology, structure, tasks, educational and professional potential of the staff and factors of the enterprise external environment (customers, competitors, suppliers, intermediaries, contact audience, etc. in order to ensure a qualitatively new level of its development and formation of its prospects. It is determined that the key business indicators of the system for diagnostics of enterprise export potential are: the level of enterprises competitiveness in the international (global market; the level of competitiveness of enterprise products; the level of competitiveness of enterprise export products; the level of enterprise resource opportunities; the level of enterprise export performance. Prospects for further research in this direction are to develop a classification (specifically detailed list of objectives of the enterprise diagnostics by the level of detail (element, partial, complex, taking into account diagnostics of export potential of the enterprise as part of diagnostic objective.

  10. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  11. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    Science.gov (United States)

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  12. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  13. Plasma diagnostic reflectometry

    International Nuclear Information System (INIS)

    Cohen, B.I.; Afeyan, B.B.; Garrison, J.C.; Kaiser, T.B.; Luhmann, N.C. Jr.; Domier, C.W.; Chou, A.E.; Baang, S.

    1996-01-01

    Theoretical and experimental studies of plasma diagnostic reflectometry have been undertaken as a collaborative research project between the Lawrence Livermore National Laboratory (LLNL) and the University of California Department of Applied Science Plasma Diagnostics Group under the auspices of the Laboratory Directed Research and Development Program at LLNL. Theoretical analyses have explored the basic principles of reflectometry to understand its limitations, to address specific gaps in the understanding of reflectometry measurements in laboratory experiments, and to explore extensions of reflectometry such as ultra-short-pulse reflectometry. The theory has supported basic laboratory reflectometry experiments where reflectometry measurements can be corroborated by independent diagnostic measurements

  14. Diagnostic reference levels in medical imaging

    International Nuclear Information System (INIS)

    Rosenstein, M.

    2001-01-01

    The paper proposes additional advice to national or local authorities and the clinical community on the application of diagnostic reference levels as a practical tool to manage radiation doses to patients in diagnostic radiology and nuclear medicine. A survey was made of the various approaches that have been taken by authoritative bodies to establish diagnostic reference levels for medical imaging tasks. There are a variety of ways to implement the idea of diagnostic reference levels, depending on the medical imaging task of interest, the national or local state of practice and the national or local preferences for technical implementation. The existing International Commission on Radiological Protection (ICRP) guidance is reviewed, the survey information is summarized, a set of unifying principles is espoused and a statement of additional advice that has been proposed to ICRP Committee 3 is presented. The proposed advice would meet a need for a unifying set of principles to provide a framework for diagnostic reference levels but would allow flexibility in their selection and use. While some illustrative examples are given, the proposed advice does not specify the specific quantities to be used, the numerical values to be set for the quantities or the technical details of how national or local authorities should implement diagnostic reference levels. (author)

  15. Recent developments of ECE diagnostics at JET

    Energy Technology Data Exchange (ETDEWEB)

    Luna, E. de la; Sanchez, J. [Association Euratom-Ciemat para Fusion, Ciemant (Spain); Cientoli, C.; Blanchard, P.; Joffrin, E.; Mazon, D. [Association Euratom-ENEA sulla Fusione, IFP-CNR, Milano (Italy); Riva, M.; Zerbini, M. [Association Euratom-ENEA sulla Fusione Centro Ricerche Energia Frascati (Italy); Conway, G. [IPP-Euratom Association, Garching (Germany); Felton, R.; Fessey, J.; Gowers, C. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom); Murari, A. [Consorzio RFX, Association Euratom-ENEA sulla Fusione, Padova (Italy)

    2004-07-01

    In JET, two types of ECE (electron cyclotron emission) instruments are routinely operated to provide electron temperature measurements: a Michelson interferometer and a heterodyne radiometer. ECE diagnostics are able to provide time-resolved electron temperature profiles with high spatial and temporal resolution, and have proven to play a fundamental role in the investigation and development of internal transport barriers (ITBs) in JET. In this paper we report on the major upgrade of the ECE diagnostics systems currently in progress at JET. Diagnostic developments include an upgrade of the multi-channel heterodyne radiometer, aimed at extending the radial region over which T{sub e} measurement can be performed, and the installation of a new Michelson interferometer with fast scanning capability, to improve the frequency and temporal resolution of the multi-harmonic ECE measurements at JET. Moreover, a future extension of the ECE system, an oblique ECE diagnostic to measure the ECE spectra at different angles with respect to the normal to the magnetic field, is being developed. This diagnostic is expected to give valuable insight into the interpretation of ECE measurements in high T{sub e}-plasmas and should be available for measurements once JET resumes operation in 2005.In this paper, the recent developments in the JET ECE diagnostic system will be described and illustrated with some recent results, with an emphasis on issues related with calibration stability, high-Te plasmas and ITB studies. Some of these issues will be discussed in the context of ITER.

  16. HEPATORENAL SYNDROME: DIAGNOSTIC AND THERAPEUTIC MANAGEMENT

    Directory of Open Access Journals (Sweden)

    I. G. Bakulin

    2014-01-01

    Full Text Available The practical guidelines on diagnosis and management of hepatorenal syndrome, which could be useful for general medical practitioners, gastroenterologists, and hepatologists, are considered in this paper. Selected recommendations are based on integrated clinical data, international recommendations and results of clinical trials. Beginning from theoretical grounds of hepatorenal syndrome (its definition, diagnostic criteria, and classification, acute kidney injury, and spontaneous bacterial peritonitis, the paper contains diagnostic algorithms (in particular, in ascites, for early revealing hepatorenal syndrome, and main approaches to therapy and prevention. The efficacy criteria and monitoring rules for the terlipressin-based therapy are listed.

  17. Equipment for radiation diagnostics

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.

    1976-01-01

    The invention relates to an improvement of the line type of the plotter in an X-ray diagnostics apparatus enabling the production of distinguishable recordings by means of a single plot type. The construction is described explicitly. (UWI) [de

  18. National Convective Weather Diagnostic

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Current convective hazards identified by the National Convective Weather Detection algorithm. The National Convective Weather Diagnostic (NCWD) is an automatically...

  19. Diagnostic radiology: I

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter describes the historic development of diagnostic equipment for radiology. The problems associated with fluoroscope design are detailed and the current uses of updated technology, particularly digitization, are considered. Numerous historical photographs are included. 13 refs

  20. Prenatal Genetic Diagnostic Tests

    Science.gov (United States)

    ... are available for many inherited disorders. The main disadvantage is that diagnostic testing carries a very small ... chromosomes, arranged in order of size. Microarray: A technology that examines all of a person’s genes to ...

  1. Exosomes - new topic in diagnostics of cancer

    International Nuclear Information System (INIS)

    Zduriencikova, M.; Gronesova, P.; Cholujova, D.; Hunakova, L.; Sedlak, J.

    2015-01-01

    Exam's, membrane vesicles with diameter in the range of 30 -100 nm, are produced by nearly all types of cells, including tumor ones. Because the molecular profile of exosomes reflects the composition of producing cells, exosomes represent the suitable source of potential bio markers for detection of malignant population. The aim of this mini review is to provide basic information about biogenesis of exosomes and some examples of their exploitation in tumor diagnostics. (author)

  2. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  3. Bovine subclinical mastitis diagnostics, treatment and prophylaxis

    OpenAIRE

    Klimaitė, Jūratė

    2005-01-01

    The distribution of yeast fungi has been ascertained as their influence on SCM etiology. Our developed preparation for treatment for yeast and microbe caused mastitis “Gentafung” is composition of wide spectrum antibiotics and antifungal medications. An evaluation was performed of commercially available homeopathic preparations in treating SCM. A new recommended preparation “OrbeScal” was evaluated for drying cows. A comparison of Candida genus commercial identification systems diagnostic acc...

  4. Molecular diagnostics of periodontitis

    OpenAIRE

    Izabela Korona-Głowniak; Radosław Siwiec; Marcin Berger; Anna Malm; Jolanta Szymańska

    2017-01-01

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridi...

  5. Alternative international currencies

    Directory of Open Access Journals (Sweden)

    Rozhentsova Vladimirovna Elena

    2012-01-01

    Full Text Available The modern international monetary system has a number of flaws and therefore needs cardinal change. Hence, economists from all over the world are suggesting alternative international currencies that would make the international monetary system more efficient. However, it is essential when approaching the creation of a new international currency to analyze and take into account the experience of all the past international currencies. Therefore this paper begins with an exploration of the drawbacks of each of the past and present international currencies. Drawing on this analysis a justification will be made for the necessity of introducing a new international currency, pointing to the requirements it should meet. Further on, this paper proposes an alternative theoretically possible variant of the international currency, with a fixed value relative to a commodity basket. An abstract example is used to demonstrate its composition and circulation mechanism.

  6. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  7. Study the Properties of Sodium Silicate Composite as a Barrier Separating Between the Internal Oil Distillation Towers and Chemical Fumes of Crude Oil

    Directory of Open Access Journals (Sweden)

    سلام حسين علي

    2016-07-01

    Full Text Available The study of surface hardness, wear resistance, adhesion strength, electrochemical corrosion resistance and thermal conductivity of coatings composed from sodium silicate was prepared using graphite micro-size particles and carbon nano particles as fillers respectively of concentration of (1-5%, for the purpose of covering and protecting the oil distillation towers. The results showed that the sodium silicate coating reinforced with carbon nano-powder has higher resistance to stitches, mechanical wear, adhesive and thermal conductivity than graphite/sodium silicate composite especially when the ratio 5% and 1%, the electrochemical corrosion test confirmed that the coating process of stainless steel 304 lead to increasing the corrosion resistance, where the reinforcing of sodium silicate lead to a significant improvement in the corrosion resistance, the corrosion resistance behavior change depending on the type of reinforcement material, this is consistent with the field test results.

  8. Combined DC resistivity and induced polarization (DC-IP) for mapping the internal composition of a mine waste rock pile in Nova Scotia, Canada

    Science.gov (United States)

    Power, Christopher; Tsourlos, Panagiotis; Ramasamy, Murugan; Nivorlis, Aristeidis; Mkandawire, Martin

    2018-03-01

    Mine waste rock piles (WRPs) can contain sulfidic minerals whose interaction with oxygen and water can generate acid mine drainage (AMD). Thus, WRPs can be a long-term source of environmental pollution. Since the generation of AMD and its release into the environment is dependent on the net volume and bulk composition of waste rock, effective characterization of WRPs is necessary for successful remedial design and monitoring. In this study, a combined DC resistivity and induced polarization (DC-IP) approach was employed to characterize an AMD-generating WRP in the Sydney Coalfield, Nova Scotia, Canada. Two-dimensional (2D) DC-IP imaging with 6 survey lines was performed to capture the full WRP landform. 2D DC results indicated a highly heterogeneous and moderately conductive waste rock underlain by a resistive bedrock containing numerous fractures. 2D IP (chargeability) results identified several highly-chargeable regions within the waste, with normalized chargeability delineating regions specific to waste mineralogy only. Three-dimensional (3D) DC-IP imaging, using 17 parallel lines on the plateau of the pile, was then used to focus on the composition of the waste rock. The full 3D inverted DC-IP distributions were used to identify coincident and continuous zones (isosurfaces) of low resistivity (0.4 mS/m) that were inferred as generated AMD (leachate) and stored AMD (sulfides), respectively. Integrated geological, hydrogeological and geochemical data increased confidence in the geoelectrical interpretations. Knowledge on the location of potentially more reactive waste material is extremely valuable for improved long-term AMD monitoring at the WRP.

  9. An Assessment of Elemental Compositions and Concentrations in a Marble Sample from Hatnub Area using Internal Mono Standard Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Soliman, N.F.; EL-Shershaby, A.; EL-Bahi, S.; Walley El-Dine, N.; Abd El-Halim, E.S.; Afifi, S.

    2012-01-01

    A marble sample was taken from Hatnub area near Asyot, where a high pollution is expected. The sample was specially treated and prepared for elemental analysis using the k 0 -based internal mono standard neutron activation analysis . The irradiation facility of the first Egyptian Training Research Reactor (ETRR-1) was used to irradiate the sample together with gold and zirconium monitor samples. The pneumatic irradiation rabbit system (PIRS) built in the vertical thermal column of the second Egyptian Training Research Reactor (ETRR-2) was used to irradiate another weight of the marble sample and a sample from a certificated reference material JB-1 for short time irradiation. A new method was developed to measure the thermal to epithermal neutron flux ratio and the deviation in the real epithermal neutron spectrum ( 1/E 1±a lpha ) from the ideal (1/E ). The elemental analysis was carried out by high-resolution gamma-ray spectrometry. The accuracy of the internal mono standard method has been evaluated by analyzing the JB-1 certified reference material

  10. Safety of Medical Diagnostic Ultrasound

    International Nuclear Information System (INIS)

    Breyer, B.

    1998-01-01

    Large numbers of people (both sick and healthy) are routinely exposed to ultrasound waves. We shall discuss wave parameters and scanner properties that are relevant to the safety aspect. This includes central pulse frequency, pulse length, intensity (ISPTA and others), focusing, pulse repetition frequency, pulse pressure, etc. Since the transmitted ultrasound power has steadily been increasing during the last two decades, the problems are becoming more serious with time. Doppler methods have gained importance and 'popularity, which additionally increases ultrasound power requirements since the reflectivity of red blood cells is so small that the backscattered pressure is about 100 times less than that from soft tissue structures in the body. Main mechanisms that can potentially present hazard are heating and cavitation. The basic parameter used to assess thermal hazard is ISPTA and the optimal predictor of cavitation hazard is the peak rarefractional pressure. The hazard of heating-up can be summarized in saying that temperatures up to 38.5 o C are safe, while temperatures above 41 o C are definitely not. Care must be taken to stay within the safe zone. However, there does not exist a confirmed report of any type of hazardous effects on humans using intensities presently applied in diagnostic ultrasound scanners. Taking this into account, various international bodies have put limits to the application of ultrasound, which is best summarized in the FDA (USA) regulation that diagnostic apparatus may have an output of maximally 720 mW/cm 2 (derated) provided thermal and mechanical properties are indicated (onscreen) by properly defined Thermal Indices (TI) and Mechanical Index (MI). These aspects shall be discussed in some detail. We shall give the rules for the operator to apply ultrasound with minimal hazard. The general conclusion is that diagnostic ultrasound, as presently known, may be used whenever a qualified expert expects essential medical benefit for the

  11. Godiva and Juliet Diagnostics CED-1 (IER-176)

    Energy Technology Data Exchange (ETDEWEB)

    Scorby, J C

    2011-12-21

    A suite of diagnostics are being proposed for use in the Juliet experiment (IER-128). In order to calibrate and test the diagnostics prior to use, the LLNL calibration facility and Godiva pulsed reactor will be used to provide intense sources of neutrons and gammas. Due to the similarities of the Godiva and Juliet radiation fields, the diagnostics being developed and tested for Juliet can also play an on-going role in diagnostics for Godiva as well as, perhaps, other critical assembly experiments. Similar work is also being conducted for IER-147 for the purpose of characterizing the Godiva radiation field in support of an upcoming international nuclear accident dosimetry exercise. Diagnostics developed and fielded under IER-147 can provide valuable data with respect to the neutron and gamma energy spectrums in the vicinity of Godiva which is relevant to the calibration of Juliet diagnostics.

  12. Evaluation of the internalization kinetics of the radiopharmaceutical 99mTc-N2S2-Tat(49-57)Lys3-Bn with diagnostic purposes, using comet assay

    International Nuclear Information System (INIS)

    Luna G, M. A.

    2011-01-01

    Gastrin-rea leasing peptide receptors (GRP-r) are over expressed in breast and prostate cancer cells. Bombesin (Bn) binds specifically and strongly to GRP-r and this is the base for to label the Bn with radionuclides by gamma rays. Tat (49-57) is a peptide that across the cell membrane easily so that, when it is conjugated to different proteins, it can works as a Trojan horse, facilitating the drug internalization to the cells. The radiopharmaceutical 99m Tc-N 2 S 2 -Tat(49-57)-Lys 3 -Bn was prepared for diagnosis and therapy at early stage of breast cancer. The objective of this study was to determine the role of Tat in the internalization kinetics of radiopharmaceuticals measured by DNA damage induced by means of comet assay. Human lymphocytes were treated with the following protocols: a) Tat-Bn, b) 99m Tc-Bn, or c) 99m Tc-N 2 S 2 -Tat(49-57)-Lys 3 -Bn, also an untreated group was conformed. The internalization was evaluated at 0, 5, 10, 15, 30 and 60 min after exposure with three repetitions each one, and for radiopharmaceuticals with 2.9, 6.6, 9.0 and 14.8 MBq activities. DNA damage was scored in 100 cells per time and treatment, as tail length and tail moment. A Kruskal-Wallis variance analysis with p≤ 0.05 was applied for comparison between treatments. The results showed that the damage caused by 99m Tc-N 2 S 2 -Tat(49-57)-Lys 3 -Bn is significantly higher than that caused by 99m Tc-Bn and Tat-Bn, showing that Tat favors the internalization of the radiopharmaceutical. (Author)

  13. Nordic working group for medical x-ray diagnostics: Diagnostic reference levels within xray diagnostics - experiences in the Nordic countries

    International Nuclear Information System (INIS)

    Leitz, W.; Groen, P.; Servomaa, A.; Einarsson, G.; Olerud, H.

    2003-01-01

    Medical x-ray diagnostics is one of the few applications of ionising radiation where people are irradiated on purpose. The strategy for radiation protection is also different compared to that in other areas that have the zero-alternative as its ultimate goal, meaning that no human beings at all are exposed in these practices. The focus in x-ray diagnostics concerning radiation protection is justification and optimisation. Optimisation implies that the examination is performed in such a way that the radiation dose is as small as possible without jeopardising the diagnostic security. X- ray diagnostics is a complex method where many technical parameters and methodology factors together are interacting in the determination of radiation dose and image quality. The optimisation process is not a simple and uncomplicated procedure, this difficulty is reflected in many international and national surveys showing a large spread of patient doses for one and the same type of examination. The concept diagnostic reference levels (DRL) has been introduced as a tool for reducing this wide distribution that is obviously indicating a lack of optimisation, and for cutting the highest radiation doses. In this presentation the concept for DRL and the experience gained in the Nordic countries with DRL are described. (orig.)

  14. Main results of investigation of natural water composition of the Syrdariya river basin at the territory of Kazakhstan (international project 'Navruz')

    International Nuclear Information System (INIS)

    Kadyrzhanov, K.K.; Solodukhin, V.P.; Khazhekber, S.; Poznyak, V.L.; Kazachevskiy, I. V.; Kabirova, G.M.; Smetannikov, V. V.; Gabdulin, R.M.; Chernykh, E.E.; Musrepov, A.D.

    2005-01-01

    Full text: This report presents the main investigation results of general physical-and-chemical parameters of water, as well as macro- and micro element composition of water and other objects of the environment taken in Syrdariya river basin at the territory of Kazakhstan during 6 expeditions. Basic emphasis here was placed on new results of the last expedition. Physical-and-chemical parameters of water (E i ; μSm/cm - specific conductivity; TDC, g/1 - total amount of dissolved substances;g/1 - mineralization, pH degree; ORP, mV - reductive-oxidative potential) were determined with the help of the 'Hydrolab' device. For study of macro- and microelement composition of the environment objects the were used X-Ray-fluorescent analyses (XRFA), NAA and γ-spectrornetry methods. All analytical methods (including sample preparation) used in these investigations. According to investigation results of chemical-and-physical features of water of the Syrdariya river and its tributaries there is determined. That overage value for pH was 8.0+0.2 and reductive-oxidative potential (ORP) was 400+40 mV. During the all expeditions a change of E c and TDC value was revealed in headwaters of the Syrdariya river, where its tributaries exerts a considerable influence. Especially, it is determined that waters of the Keles and Kurkeles river are characterized by high physical and chemical indicators: TDC - up to 2.6 g/l, E c - up to 4000 μSm/cm. Down the last tributary (the Arys river) there was no any seasonal changes determined in values of these parameters. On this run of the Syrdariya river average value for E c is (1620+80) μSm/cm and for TDC is (1.04+0.05) g/l. According to the investigation results of the element composition of the environment objects there were revealed high concentrations of Cr, Fe, Co, Ni, Zn, As, La, Ce, Th in bottom sediments of headwaters of the Syrdariya river (above the Shardara reservoir). One can suppose that these microelements come with water of Keles

  15. LHD neutron diagnostics

    International Nuclear Information System (INIS)

    Isobe, M.; Ogawa, K.; Kobuchi, T.

    2015-01-01

    The Large Helical Device (LHD) project will step into a next stage, i.e. experiment by using deuterium gases after two years of preparation. A comprehensive set of neutron and γ-ray diagnostics is going to be installed on the LHD towards extension of energetic-particle (EP) physics research in heliotron plasmas. Conceptual design of fusion products diagnostics for the LHD was made in late 1990s. After conclusion of agreements for the LHD deuterium experiment with local government bodies, development of FPs diagnostics has begun lately. Because there are a lot of tasks to do, all Japan fusion neutron and γ-ray diagnostics team has been organized in the collaboration framework of National Institute for Fusion Science. FPs diagnostics system on the LHD will consist of 1) wide dynamic range neutron flux monitor (NFM), 2) neutron activation system (NAS), 3) vertical neutron camera (VNC). In addition to these, we are developing a directional scintillating fiber detector, an artificial diamond detector and a γ-ray scintillation detector for confinement study of MeV ions. A neutron energy spectrometer prototype is also being developed and tested in KSTAR. In this paper, roles of NFM, NAS and VNC and current status of implementation onto the LHD are briefly described. (author)

  16. Pitfalls in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Peh, Wilfred C.G. (ed.) [Khoo Teck Puat Hospital (Singapore). Dept. of Diagnostic Radiology

    2015-04-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  17. Pitfalls in diagnostic radiology

    International Nuclear Information System (INIS)

    Peh, Wilfred C.G.

    2015-01-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  18. Production and characterization of ceramic composite Al_2O_3-TiO_2 reinforced with Y_2O_3 and its stability in crude oil for internal coating of petroleum tankers

    International Nuclear Information System (INIS)

    Yadava, Y.P.; David, N.R.; Sanguinetti Ferreira, R.A.; Shinohara, A.H.

    2014-01-01

    The internal surfaces of crude petroleum tankers are subjected to corrosive environments, therefore it is of great importance to research coatings for the protection of those structures. Ceramic materials generally exhibit characteristic chemical inertness and are shown as material option for this application. In this study alumina-titania ceramic composites have been produced and reinforced with yttria. These composites were produced by thermo-mechanical process, sintered at 1350 ° C for 24 hours, and left to cool down in the oven. The structural and microstructural characterization of the sintered material was tested by X-ray diffraction and scanning electron microscopy. And its mechanical property was studied by Vickers microhardness test. After this characterization, the samples underwent a stability test where they were immersed in crude oil at room temperature for 60 days, during which were periodically subjected to tests related to stability, which was found found that the material was free from cracks, fissures or fractures, presenting for these reasons characteristics of inertia when subjected to crude oil environment. (author)

  19. Quality systems in veterinary diagnostics laboratories.

    Science.gov (United States)

    de Branco, Freitas Maia L M

    2007-01-01

    Quality assurance of services provided by veterinary diagnostics laboratories is a fundamental element promoted by international animal health organizations to establish trust, confidence and transparency needed for the trade of animals and their products at domestic and international levels. It requires, among other things, trained personnel, consistent and rigorous methodology, choice of suitable methods as well as appropriate calibration and traceability procedures. An important part of laboratory quality management is addressed by ISO/IEC 17025, which aims to facilitate cooperation among laboratories and their associated parties by assuring the generation of credible and consistent information derived from analytical results. Currently, according to OIE recommendation, veterinary diagnostics laboratories are only subject to voluntary compliance with standard ISO/IEC 17025; however, it is proposed here that OIE reference laboratories and collaboration centres strongly consider its adoption.

  20. Reversed field pinch diagnostics

    International Nuclear Information System (INIS)

    Weber, P.G.

    1986-01-01

    The Reversed Field Pinch (RFP) is a toroidal, axisymmetric magnetic confinement configuration characterized by a magnetic field configuration in which the toroidal magnetic field is of similar strength to the poloidal field, and is reversed at the edge compared to the center. The RFP routinely operates at high beta, and is a strong candidate for a compact fusion device. Relevant attributes of the configuration will be presented, together with an overview of present and planned experiments and their diagnostics. RFP diagnostics are in many ways similar to those of other magnetic confinement devices (such as tokamaks); these lectures will point out pertinent differences, and will present some diagnostics which provide special insights into unique attributes of the RFP

  1. Metabolomics for laboratory diagnostics.

    Science.gov (United States)

    Bujak, Renata; Struck-Lewicka, Wiktoria; Markuszewski, Michał J; Kaliszan, Roman

    2015-09-10

    Metabolomics is an emerging approach in a systems biology field. Due to continuous development in advanced analytical techniques and in bioinformatics, metabolomics has been extensively applied as a novel, holistic diagnostic tool in clinical and biomedical studies. Metabolome's measurement, as a chemical reflection of a current phenotype of a particular biological system, is nowadays frequently implemented to understand pathophysiological processes involved in disease progression as well as to search for new diagnostic or prognostic biomarkers of various organism's disorders. In this review, we discussed the research strategies and analytical platforms commonly applied in the metabolomics studies. The applications of the metabolomics in laboratory diagnostics in the last 5 years were also reviewed according to the type of biological sample used in the metabolome's analysis. We also discussed some limitations and further improvements which should be considered taking in mind potential applications of metabolomic research and practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Corpuscular plasma diagnostics

    International Nuclear Information System (INIS)

    Afrosimov, V.; Petrov, M.

    1984-01-01

    An elementary explanation is presented of the physical principles and important methods of corpuscular plasma diagnostics. The invaluable role of corpuscular methods for measuring the hot plasma ion component in thermonuclear facilities, especially hydrogen ions in tokamaks, is emphasized. All corpuscular methods employ analysis of fast neutral atoms and therefore the mechanism of their creation inside a hot plasma is explained first. The ammount of information obtainable from spectra of fast neutrals is discussed. Multichannel analyzers developed at the FTI A.F. Ioffe in Leningrad are described in detail. Classical passive corpuscular diagnostics are examined as are active methods using artifitial beams of hydrogen atoms. The method used for obtaining local values of ion temperature and density is explained. Corpuscular spectroscopic diagnostics and its application for measuring impurities is mentioned. (J.U.)

  3. [Cytology in uropathological diagnostics].

    Science.gov (United States)

    Gaisa, N T; Lindemann-Docter, K

    2015-11-01

    Cytology in uropathological diagnostics is mainly performed for oncological purposes. The assessment of malignancy by urothelial cell morphology is therefore decisive; however, cytology is only sensitive enough to detect high-grade tumor cells and the different low-grade tumors cannot be reliably diagnosed. Thus, the four-tier classification system of cytological findings (i.e. negative, atypical cells but significance uncertain, suspicious and positive) refers to high-grade tumor cells only. Furthermore, for valid cytological diagnostics not only the cytological specimen but also clinical information on cystoscopy findings and, if applicable, a biopsy should be evaluated together. In difficult differential diagnostic settings, e.g. differentiation between reactive versus neoplastic atypia or difficult to access lesions in the upper urinary tract, additional fluorescence in situ hybridization of cytological preparations might be helpful. At the moment there are no indications for further immunocytology or additional biomarker tests.

  4. Nova diagnostics summary

    International Nuclear Information System (INIS)

    Slivinsky, V.W.; Drake, R.P.

    1985-01-01

    The authors intend that Nova be the best diagnosed ICF research facility in operation today. The authors experience in providing advanced diagnostics for previous laser systems will be extended at Nova, and will be challenged by the development of new instrumentation to diagnose the more advanced targets made possible by this powerful laser. Previous experience has shown that to understand target performance, the authors must have as complete a set of diagnostics as possible. The Nova diagnostics are divided into two sets: the basic set required for the initial Nova experiments and the more advanced set for later, generally more complex, experiments. The basic set will be operational for the first Nova shots; it was a Nova line item funded with Nova construction money. This basic set is presented in a table

  5. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  6. Effect of barrier height and indium composition on the internal quantum efficiency of (In)AlGaN multiple quantum well structures

    Energy Technology Data Exchange (ETDEWEB)

    Ledentsov, Nikolay Jr.; Reich, Christoph; Mehnke, Frank; Kuhn, Christian; Wernicke, Tim; Kolbe, Tim; Lobo Ploch, Neysha; Rass, Jens [Institute of Solid State Physics, Technische Universitaet Berlin (Germany); Kueller, Viola [Ferdinand-Braun-Institut, Berlin (Germany); Kneissl, Michael [Institute of Solid State Physics, Technische Universitaet Berlin (Germany); Ferdinand-Braun-Institut, Berlin (Germany)

    2013-07-01

    We studied (In)AlGaN multiple quantum wells (MQWs) emitting in the UV-B spectral region with photoluminescence and electroluminescence spectroscopy. The internal quantum efficiency (IQE) was determined by temperature dependent measurements (5 K-300 K). The quantum confined Stark effect (QCSE) was investigated by studying the shift of the emission energy with increasing excitation power density. In the first series, Al{sub 0.27}Ga{sub 0.73}N MQWs with different Al{sub x}Ga{sub 1-x}N barriers (0.32

  7. A non-destructive, ultrasonic method for the determination of internal pressure and gas composition in an LWR fuel rod on-going and future programme

    International Nuclear Information System (INIS)

    Ferrandis, J.; Leveque, G.; Villard, J.

    2006-01-01

    Several possible non-destructive methods have been investigated in the past to measure the internal gas pressure e.g., measurement of 85 Kr directly, or after accumulation in the plenum by freezing with liquid nitrogen. However no satisfactory resolution to the problem has been found, so at present there is no rapid and accurate method of determining the fission gas pressure in a fuel rod without puncturing the cladding. This procedure is time-consuming and expensive and as a consequence a relatively small number of measurements are generally made compared with the number of fuel rods irradiated. In this paper it is proposed a new method for the measurement of pressure that is: Non-destructive; Non-invasive (i.e., allows re-irradiation of the measured rod); Easy to operate - directly in the reactor pool; Can be used on the critical path; Is inexpensive compared with the methods currently in use. This method is also being adapted to the on line measurement of fission gas release on fuel irradiation in research reactors. This method is based on the application of acoustic technology

  8. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  9. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  10. Probability of major depression diagnostic classification using semi-structured versus fully structured diagnostic interviews.

    Science.gov (United States)

    Levis, Brooke; Benedetti, Andrea; Riehm, Kira E; Saadat, Nazanin; Levis, Alexander W; Azar, Marleine; Rice, Danielle B; Chiovitti, Matthew J; Sanchez, Tatiana A; Cuijpers, Pim; Gilbody, Simon; Ioannidis, John P A; Kloda, Lorie A; McMillan, Dean; Patten, Scott B; Shrier, Ian; Steele, Russell J; Ziegelstein, Roy C; Akena, Dickens H; Arroll, Bruce; Ayalon, Liat; Baradaran, Hamid R; Baron, Murray; Beraldi, Anna; Bombardier, Charles H; Butterworth, Peter; Carter, Gregory; Chagas, Marcos H; Chan, Juliana C N; Cholera, Rushina; Chowdhary, Neerja; Clover, Kerrie; Conwell, Yeates; de Man-van Ginkel, Janneke M; Delgadillo, Jaime; Fann, Jesse R; Fischer, Felix H; Fischler, Benjamin; Fung, Daniel; Gelaye, Bizu; Goodyear-Smith, Felicity; Greeno, Catherine G; Hall, Brian J; Hambridge, John; Harrison, Patricia A; Hegerl, Ulrich; Hides, Leanne; Hobfoll, Stevan E; Hudson, Marie; Hyphantis, Thomas; Inagaki, Masatoshi; Ismail, Khalida; Jetté, Nathalie; Khamseh, Mohammad E; Kiely, Kim M; Lamers, Femke; Liu, Shen-Ing; Lotrakul, Manote; Loureiro, Sonia R; Löwe, Bernd; Marsh, Laura; McGuire, Anthony; Mohd Sidik, Sherina; Munhoz, Tiago N; Muramatsu, Kumiko; Osório, Flávia L; Patel, Vikram; Pence, Brian W; Persoons, Philippe; Picardi, Angelo; Rooney, Alasdair G; Santos, Iná S; Shaaban, Juwita; Sidebottom, Abbey; Simning, Adam; Stafford, Lesley; Sung, Sharon; Tan, Pei Lin Lynnette; Turner, Alyna; van der Feltz-Cornelis, Christina M; van Weert, Henk C; Vöhringer, Paul A; White, Jennifer; Whooley, Mary A; Winkley, Kirsty; Yamada, Mitsuhiko; Zhang, Yuying; Thombs, Brett D

    2018-06-01

    Different diagnostic interviews are used as reference standards for major depression classification in research. Semi-structured interviews involve clinical judgement, whereas fully structured interviews are completely scripted. The Mini International Neuropsychiatric Interview (MINI), a brief fully structured interview, is also sometimes used. It is not known whether interview method is associated with probability of major depression classification.AimsTo evaluate the association between interview method and odds of major depression classification, controlling for depressive symptom scores and participant characteristics. Data collected for an individual participant data meta-analysis of Patient Health Questionnaire-9 (PHQ-9) diagnostic accuracy were analysed and binomial generalised linear mixed models were fit. A total of 17 158 participants (2287 with major depression) from 57 primary studies were analysed. Among fully structured interviews, odds of major depression were higher for the MINI compared with the Composite International Diagnostic Interview (CIDI) (odds ratio (OR) = 2.10; 95% CI = 1.15-3.87). Compared with semi-structured interviews, fully structured interviews (MINI excluded) were non-significantly more likely to classify participants with low-level depressive symptoms (PHQ-9 scores ≤6) as having major depression (OR = 3.13; 95% CI = 0.98-10.00), similarly likely for moderate-level symptoms (PHQ-9 scores 7-15) (OR = 0.96; 95% CI = 0.56-1.66) and significantly less likely for high-level symptoms (PHQ-9 scores ≥16) (OR = 0.50; 95% CI = 0.26-0.97). The MINI may identify more people as depressed than the CIDI, and semi-structured and fully structured interviews may not be interchangeable methods, but these results should be replicated.Declaration of interestDrs Jetté and Patten declare that they received a grant, outside the submitted work, from the Hotchkiss Brain Institute, which was jointly funded by the Institute and Pfizer. Pfizer was the

  11. Electromagnetic diagnostic system for the Keda Torus eXperiment

    Science.gov (United States)

    Tu, Cui; Liu, Adi; Li, Zichao; Tan, Mingsheng; Luo, Bing; You, Wei; Li, Chenguang; Bai, Wei; Fu, Chenshuo; Huang, Fangcheng; Xiao, Bingjia; Shen, Biao; Shi, Tonghui; Chen, Dalong; Mao, Wenzhe; Li, Hong; Xie, Jinglin; Lan, Tao; Ding, Weixing; Xiao, Chijin; Liu, Wandong

    2017-09-01

    A system for electromagnetic measurements was designed and installed on the Keda Torus eXperiment (KTX) reversed field pinch device last year. Although the unique double-C structure of the KTX, which allows the machine to be opened easily without disassembling the poloidal field windings, makes the convenient replacement and modification of the internal inductive coils possible, it can present difficulties in the design of flux coils and magnetic probes at the two vertical gaps. Moreover, the KTX has a composite shell consisting of a 6 mm stainless steel vacuum chamber and a 1.5 mm copper shell, which results in limited space for the installation of saddle sensors. Therefore, the double-C structure and composite shell should be considered, especially during the design and installation of the electromagnetic diagnostic system (EDS). The inner surface of the vacuum vessel includes two types of probes. One type is for the measurement of the global plasma parameters, and the other type is for studying the local behavior of the plasma and operating the new saddle coils. In addition, the probes on the outer surface of the composite shell are used for measurements of eddy currents. Finally, saddle sensors for radial field measurements for feedback control were installed between the conducting shell and the vacuum vessel. The entire system includes approximately 1100 magnetic probes, 14 flux coils, 4 ×26 ×2 saddle sensors, and 16 Rogowski coils. Considering the large number of probes and limited space available in the vacuum vessel, the miniaturization of the probes and optimization of the probe distribution are necessary. In addition, accurate calibration and careful mounting of the probes are also required. The frequency response of the designed magnetic probes is up to 200 kHz, and the resolution is 1 G. The EDS, being spherical and of high precision, is one of the most basic and effective diagnostic tools of the KTX and meets the demands imposed by requirements on

  12. Implementation of a Clinical Reasoning Course in the Internal Medicine trimester of the final year of undergraduate medical training and its effect on students' case presentation and differential diagnostic skills.

    Science.gov (United States)

    Harendza, Sigrid; Krenz, Ingo; Klinge, Andreas; Wendt, Ulrike; Janneck, Matthias

    2017-01-01

    Background: Clinical reasoning, comprising the processes of clinical thinking, which form the basis of medical decisions, constitutes a central competence in the clinical routine on which diagnostic and therapeutic steps are based. In medical curricula in Germany, clinical reasoning is currently taught explicitly only to a small extend. Therefore, the aim of this project was to develop and implement a clinical reasoning course in the final year of undergraduate medical training. Project description: A clinical reasoning course with six learning units and 18 learning objectives was developed, which was taught by two to four instructors on the basis of 32 paper cases from the clinical practice of the instructors. In the years 2011 to 2013, the course of eight weeks with two hours per week was taught seven times. Before the first and after the last seminar, the participating students filled out a self-assessment questionnaire with a 6-point Likert scale regarding eight different clinical reasoning skills. At the same times, they received a patient case with the assignment to prepare a case presentation and differential diagnoses. Results: From 128 participating students altogether, 42 complete data sets were available. After the course, participants assessed themselves significantly better than before the course in all eight clinical reasoning skills, for example in "Summarizing and presentation of a paper case" or in the "Skill to enumerate differential diagnoses" (ppresentation of the paper case was significantly more focused after the course (p=0.011). A significant increase in the number of gathered differential diagnoses was not detected after the course. Conclusion: The newly developed and established Clinical Reasoning Course leads to a gain in the desired skills from the students' self-assessment perspective and to a more structured case presentation. To establish better options to exercise clinical reasoning, a longitudinal implementation in the medical

  13. Crustal structure and composition to the S of the Spanish Central System: Effect of Alpine reactivation in an internal Variscan domain

    Science.gov (United States)

    Ayarza, Puy; Carbonell, Ramón; Ehsan, Siddique; Martí, David; Palomeras, Immaculada; Martínez Poyatos, David

    2016-04-01

    The ALCUDIA Project has acquired vertical incidence and wide-angle reflection seismic data in the Variscan Central Iberian Zone of Spain. The NE-SW, ~300 km long profiles sample an area going from the suture between the Variscan Central Iberian and the Ossa-Morena Zones in the S to the boundary between the former and the Alpine Central System to the N. Although crustal thickness appears to be fairly constant along most of the Central Iberian Zone, a gradual increase of 3-5 km in the northern half of the profile is clearly imaged by the wide-angle data. This increase in the Moho depth is accompanied by a decrease in the thickness of the layered lower crust from the Toledo Anatectic Complex to the N. Right in this area, the amount of Variscan metasediments diminish and the surface geology is characterized by granites, migmatites and by the Madrid Basin, a foreland basin of the Alpine Central System that is part of the bigger Tagus Basin. The increase in crustal thickness identified in the neighborhood of the Central System is also accompanied by a slight increase in the Poisson ratio values, which even though still below 0.25, they are higher than those observed in the southern part of the profile, far from the influence of the late Variscan melting episode and of that of the Alpine tectonics. Two scenarios are considered to take part in the Moho deepening near the Central System: Firstly, the Alpine reactivation causing this mountain belt has increased the crustal load giving rise to a foreland basin and a moderate crustal thickening. Also, a gradual change in crustal composition to the N, incorporating denser and more basic rocks, might also play a role in the average crustal density and contribute to Moho deepening by isostatic readjustment. The importance of each of these process is, as yet, unknown. However, the next acquisition of the CIMDEF project wide-angle reflection dataset across the central part of the Iberian Peninsula, crossing the Central System, will

  14. NEOCAM: Near Earth Object Chemical Analysis Mission: Bridging the Gulf between Telescopic Observations and the Chemical and Mineralogical Compositions of Asteroids or Diogenes A: Diagnostic Observation of the Geology of Near Earth Spectrally-Classified Asteroids

    Science.gov (United States)

    Nuth, Joseph A.

    2009-01-01

    Studies of meteorites have yielded a wealth of scientific information based on highly detailed chemical and isotopic studies possible only in sophisticated terrestrial laboratories. Telescopic studies have revealed an enormous (greater than 10(exp 5)) number of physical objects ranging in size from a few tens of meters to several hundred kilometers, orbiting not only in the traditional asteroid belt between Mars and Jupiter but also throughout the inner solar system. Many of the largest asteroids are classed into taxonomic groups based on their observed spectral properties and are designated as C, D. X, S or V types (as well as a wide range in sub-types). These objects are certainly the sources far the meteorites in our laboratories, but which asteroids are the sources for which meteorites? Spectral classes are nominally correlated to the chemical composition and physical characteristics of the asteroid itself based on studies of the spectral changes induced in meteorites due to exposure to a simulated space environment. While laboratory studies have produced some notable successes (e.g. the identification of the asteroid Vesta as the source of the H, E and D meteorite classes), it is unlikely that we have samples of each asteroidal spectral type in our meteorite collection. The correlation of spectral type and composition for many objects will therefore remain uncertain until we can return samples of specific asteroid types to Earth for analyses. The best candidates for sample return are asteroids that already come close to the Earth. Asteroids in orbit near 1 A.U. have been classified into three groups (Aten, Apollo & Amor) based on their orbital characteristics. These Near Earth Objects (NEOs) contain representatives of virtually all spectral types and sub-types of the asteroid population identified to date. Because of their close proximity to Earth, NEOs are prime targets for asteroid missions such as the NEAR-Shoemaker NASA Discovery Mission to Eros and the

  15. IMPLEMENTATION OF TURNOUTS TECHNICAL DIAGNOSTICS SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. YU. Buryak

    2015-06-01

    Full Text Available Purpose. In the paper it is necessary to: 1 find out the causes of turnouts faults to determine diagnostic features failures; 2 consider the requirements structure, purpose components of turnouts, work and technology of their maintenance to determine the construction of the economic activities related to system to the turnout’s maintenance; 3 substantiate the possibility, necessity and prospects of automated diagnostics turnout’s implementation; 4 elaborate a prototype of an automated hardware and software system for the turnouts control parameters and perform diagnostics on them. Methodology. In the paper possible turnouts faults were presented and manifestations and influence on its work were shown. According to the current technology works the process analyze of turnouts’ maintenance was conducted, were defined the basic performed operations during the examination of appearance, parameters and check the repair or replacement of parts and assemblies. Based on the analysis of reasons of turnouts malfunctioning and their fixes were systematized types of damages and ways to deal with them, an information scheme of troubleshooting were created, opportunities and limits of automating the process of diagnostics were identified and compared with the existing method of turnouts maintenance. A diagnostics system block diagram was created, an algorithm of its work was developed and established main basic principles of operation. Software and hardware to determine the turnout’s state considering diagnostic performance of points in use were applied. Findings. During the experiment was created a method of automated turnout’s diagnostics with AC electric drives, managed centrally. The results of automated hardware and software system make it possible to control turnout’s parameters and perform diagnostics on them. Originality. Authors created the method of turnout’s state determination by current curve and its spectral composition in the

  16. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  17. Molecular Beacons in Diagnostics

    OpenAIRE

    Tyagi, Sanjay; Kramer, Fred Russell

    2012-01-01

    Recent technical advances have begun to realize the potential of molecular beacons to test for diverse infections in clinical diagnostic laboratories. These include the ability to test for, and quantify, multiple pathogens in the same clinical sample, and to detect antibiotic resistant strains within hours. The design principles of molecular beacons have also spawned a variety of allied technologies.

  18. Diagnostic radiation and pregnancy

    International Nuclear Information System (INIS)

    Collins, L.; Fitzgerald, P.

    1983-01-01

    Accidental irradiation of the embryo or fetus in the first trimester is a problem which will occasionally occur. The value of a proper estimation of the radiation dose is emphasised. Very rarely does a single diagnostic procedure result in a uterine dose as high as 50 mGy. An accidental irradiation should rarely be cause for termination of a pregnancy

  19. Diagnostic imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Gradzki, J.; Nowak, S.; Paprzycki, W.

    1993-01-01

    40 patients have been examined with operational and histological confirmation of craniopharyngioma. CT image and X-ray plane of skull were performed in case all of these patients. TMR was conformed to examine 4 patients. X-ray planes was compared to CT. CT permits tumor cyst detection. The efficacy of mentioned above diagnostic techniques was compared with surgical findings. (author)

  20. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960's to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore's Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail

  1. Diagnostic studies in amyloidosis

    NARCIS (Netherlands)

    Hazenberg, Bouke Pier Cornelis

    2007-01-01

    In this thesis two diagnostic techniques are studied in amyloidosis. Systemic amyloidosis is characterized by deposition of amyloid fibrils (tiny fibres) throughout the body resulting in damage of vital organs. Amyloid can be detected in a tissue specimen stained with Congo red: red-stained amyloid

  2. 1968 Prototype Diagnostic Test.

    Science.gov (United States)

    Veterans Administration Hospital, Bedford, MA.

    This true-false diagnostic test was used for pretesting of employees at a Veterans Administration Hospital. The test is comprised of 20 items. An alternate test--Classification Questionnaire--was used for testing after remedial training. (For related document, see TM 002 334.) (DB)

  3. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1997-01-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at Lawrence Livermore National Laboratory (LLNL) from the early 1960s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400-ns pulses. The Advanced Test Accelerator (ATA) built at Livermore close-quote s Site 300 produced 10,000-Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and Lawrence Berkeley National Laboratory (LBNL). This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high-current, short-pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail. copyright 1997 American Institute of Physics

  4. It's diagnostics, stupid.

    Science.gov (United States)

    Bernards, René

    2010-04-02

    To stem the spiraling cost of cancer treatment, a concerted effort is urgently needed to develop molecular diagnostics to better identify the patients that respond to expensive targeted therapies. Opportunities and obstacles in the development of such drug response biomarkers are discussed here. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Diagnostics for pellet experiments

    International Nuclear Information System (INIS)

    Johnson, R.R.

    1978-01-01

    The target diagnostics which are being used and planned in current laser driven ICF Experiments are described. Most of these diagnostics can be easily applied to future ion-beam fusion experiments. The status of laser fusion diagnostics has been much improved in the last 5 years and further improvements can be expected and should be available when the first ICF experiments using ion beams are performed. As an example, x-ray temporal and spatial resolutions are now approximately 5 psec and 3 μm, which is approximately a factor of 4 better than the resolution reported in the first implosion experiments. As one plans ahead for ion-beam fusion experiments it should be emphasized that high yield experiments are easier to diagnose provided adequate shielding is employed. However, in the event that the first high yield experiments fail it will be necessary to have diagnostics available to determine where the problems lie. In laser fusion it is interesting to note that higher laser powers are required now for breakeven experiments than first anticipated, mainly because some aspects of the laser-interaction physics were not recognized until the experiments were carefully diagnosed. Thus as has been pointed out, it may be necessary to increase the energy of the ion-beam driver to enable us to do breakeven experiments with high confidence

  6. Flowfield modeling and diagnostics

    International Nuclear Information System (INIS)

    Gupta, A.K.; Lilley, D.G.

    1985-01-01

    This textbook is devoted solely to flowfield modeling and diagnostics; their practical use, recent and current research, and projected developments and trends. It provides an account of the use of a broad range of techniques in industrial and research practice, both with and without combustion. Application ideas are complemented by details about experimental and modeling techniques

  7. Serbia : Systematic Country Diagnostic

    OpenAIRE

    World Bank Group

    2015-01-01

    This Systematic Country Diagnostic (SCD) aims to identify the major constraints on and opportunities for sustaining poverty reduction and shared prosperity in Serbia. The SCD serves as the analytic foundation on which the World Bank Group and the Government of Serbia will define a new Country Partnership Framework for FY2016 to FY2020. It is based on the best possible analysis, drawing on ...

  8. Diagnostic and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J. [Klinikum der Johann Wolfgang Goethe-Universitaet, Frankfurt am Main (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Reith, Wolfgang [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Diagnostische und Interventionelle Neuroradiologie; Rummeny, Ernst J. (ed.) [Technische Univ. Muenchen Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Radiologie

    2016-08-01

    This exceptional book covers all aspects of diagnostic and interventional radiology within one volume, at a level appropriate for the specialist. From the basics through diagnosis to intervention: the reader will find a complete overview of all areas of radiology. The clear, uniform structure, with chapters organized according to organ system, facilitates the rapid retrieval of information. Features include: Presentation of the normal radiological anatomy Classification of the different imaging procedures according to their diagnostic relevance Imaging diagnosis with many reference images Precise description of the interventional options The inclusion of many instructive aids will be of particular value to novices in decision making: Important take home messages and summaries of key radiological findings smooth the path through the jungle of facts Numerous tables on differential diagnosis and typical findings in the most common diseases offer a rapid overview and orientation Diagnostic flow charts outline the sequence of diagnostic evaluation All standard procedures within the field of interventional radiology are presented in a clinically relevant and readily understandable way, with an abundance of illustrations. This is a textbook, atlas, and reference in one: with more than 2500 images for comparison with the reader's own findings. This comprehensive and totally up-to-date book provides a superb overview of everything that the radiology specialist of today needs to know.

  9. Prevalence of disability in a composite ≥75 year-old population in Spain: A screening survey based on the International Classification of Functioning

    Directory of Open Access Journals (Sweden)

    Gascon-Bayarri Jordi

    2011-03-01

    Full Text Available Abstract Background The prevalence and predictors of functional status and disability of elderly people have been studied in several European countries including Spain. However, there has been no population-based study incorporating the International Classification of Functioning, Disability and Health (ICF framework as the basis for assessing disability. The present study reports prevalence rates for mild, moderate, and severe/extreme disability by the domains of activities and participation of the ICF. Methods Nine populations surveyed in previous prevalence studies contributed probabilistic and geographically defined samples in June 2005. The study sample was composed of 503 subjects aged ≥75 years. We implemented a two-phase screening design using the MMSE and the World Health Organization-Disability Assessment Schedule 2nd edition (WHO-DAS II, 12 items as cognitive and disability screening tools, respectively. Participants scoring within the positive range of the disability screening were administered the full WHO-DAS II (36 items; score range: 0-100 assessing the following areas: Understanding and communication, Getting along with people, Life activities, Getting around, Participation in society, and Self-care. Each disability area assessed by WHO-DAS II (36 items was reported according to the ICF severity ranges (No problem, 0-4; Mild disability, 5-24; Moderate disability, 25-49; Severe/Extreme disability, 50-100. Results The age-adjusted disability prevalence figures were: 39.17 ± 2.18%, 15.31 ± 1.61%, and 10.14 ± 1.35% for mild, moderate, and severe/extreme disability, respectively. Severe and extreme disability prevalence in mobility and life activities was three times higher than the average, and highest among women. Sex variations were minimal, although life activities for women of 85 years and over had more severe/extreme disability as compared to men (OR = 5.15 95% CI 3.19-8.32. Conclusions Disability is highly prevalent among

  10. Fetal dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Faulkner, K.

    2002-01-01

    Diagnostic radiology examinations are frequently performed in all countries because of the benefit that the patient derives from the resultant diagnosis. Given that so many examinations are performed it is inevitable that there will be occasions when the planned exposure of a woman who is known to be pregnant is contemplated. In these circumstances, there must be rigorous justification of the examination and the procedure itself must be optimised as well. Radiation risks from fetal irradiation are well established. These risks fall into three categories: 1) a cancer induction risk (mainly leukaemia); 2) hereditary effects (as the fetus is a potential parent); 3) a risk of serious mental retardation (if the fetus is exposed in the critical 8-15 weeks period when the forebrain is being developed). Risk factors for these effects have been reviewed by the International Commission on Radiological Protection. Special rules apply to the radiology of women who are or who may be pregnant. These rules have been developed to avoid he unintended irradiation of the fetus. These rules have been variously referred to as the 10-day rule and the 28-day rules, in which radiology of potentially pregnant women is restricted to the first 10 or 28 days following menstruation. It is apparent that the advice provided by national bodies varies, as different rules apply internationally, due presumably to a lack of an international consensus on the subject. The advice from the National Radiological Protection Board, the College of Radiographers and the Royal College of Radiologists applies in the United Kingdom. In summary, the advice is that women of child bearing age are asked before a diagnostic radiology examination in which the pelvis is in, or near, the primary beam are asked if they are, or may be, pregnant. If pregnancy can be excluded then the examination can proceed. If it is likely that the patient is pregnant, then the proposed examination must undergo rigorous justification. If

  11. Tune-Based Halo Diagnostics

    International Nuclear Information System (INIS)

    Cameron, Peter

    2003-01-01

    Tune-based halo diagnostics can be divided into two categories -- diagnostics for halo prevention, and diagnostics for halo measurement. Diagnostics for halo prevention are standard fare in accumulators, synchrotrons, and storage rings, and again can be divided into two categories -- diagnostics to measure the tune distribution (primarily to avoid resonances), and diagnostics to identify instabilities (which will not be discussed here). These diagnostic systems include kicked (coherent) tune measurement, phase-locked loop (PLL) tune measurement, Schottky tune measurement, beam transfer function (BTF) measurements, and measurement of transverse quadrupole mode envelope oscillations. We refer briefly to tune diagnostics used at RHIC and intended for the SNS, and then present experimental results. Tune-based diagnostics for halo measurement (as opposed to prevention) are considerably more difficult. We present one brief example of tune-based halo measurement

  12. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  13. Healable Composites

    Science.gov (United States)

    2012-03-28

    oriented fibers and healable polymer matrix 4. Laminate pre-preg layers to form composite panels with minimal voids & defects 5. Characterize the...composites: determine mechanical and crack healing properties (4, 5) Composite (3) Prepreg (2) Polymer (1) Furan (1) Maleimide Healable Composites...Develop pre-preg system of oriented fibers and healable polymer matrix 4. Laminate pre-preg layers to form composite panels with minimal voids & defects

  14. Cancer pancreatis, diagnostic procedures

    International Nuclear Information System (INIS)

    Graadal, Oe.; Schlichting, E.; Aasen, A.O.; Stadaas, J.O.

    1990-01-01

    151 patients treated for carcinoma of the pancreas at Ullevaal Hospital (Oslo University) during the period 1980-89 were studied. The most common initial symptom was abdominal pain. Other frequent debut symptoms were loss of weight and jaundice. ERCP and PTC were found to be the best diagnostic procedures. CT or ultrasonography were normal in 10-20% of the patients. Nearly all tumors of the pancreas were found by the ERCP procedure. Also angiography was used to evaluate operability of the pancreas tumor, but was found to be a very uncertain diagnostic method. This method will not be used in the future evaluation of patients with cancer of the pancreas. 13 refs., 1 fig., 2 tabs

  15. Inertial confinement fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1986-10-01

    The concept and goals of ICF will be briefly reviewed and the new 100 kJ class Nova laser facility will be described. Experimental results obtained to date with Nova will be summarized, and the discussions of diagnostics will use examples on the present capabilities of Nova and new developments that are underway. The classes of diagnostic systems to be discussed fall into three basic categories: optical, x-ray, and particle. Examples of highly space resolved, time resolved, and spectrally resolved techniques as well as schemes involving combinations of these capabilities will be presented. A brief summary of the sophisticated acquisition and analysis system in use for Nova data will be provided

  16. Nanobiosensors in diagnostics

    Directory of Open Access Journals (Sweden)

    Alejandro Chamorro-Garcia

    2016-11-01

    Full Text Available Medical diagnosis has been greatly improved thanks to the development of new techniques capable of performing very sensitive detection and quantifying certain parameters. These parameters can be correlated with the presence of specific molecules and their quantity. Unfortunately, these techniques are demanding, expensive, and often complicated. On the other side, progress in other fields of science and technology has contributed to the rapid growth of nanotechnology. Although being an emerging discipline, nanotechnology has raised huge interest and expectations. Most of the enthusiasm comes from new possibilities and properties of nanomaterials. Biosensors (simple, robust, sensitive, cost-effective combined with nanomaterials, also called nanobiosensors, are serving as bridge between advanced detection/diagnostics and daily/routine tests. Here we review some of the latest applications of nanobiosensors in diagnostics field.

  17. Diagnostic radiation risks

    Energy Technology Data Exchange (ETDEWEB)

    Sherwood, T [Addenbrooke' s Hospital, Cambridge (UK)

    1980-04-01

    A brief discussion on diagnostic radiation risks is given. First some fundamental facts on the concepts and units of radiation measurement are clarified. Medical diagnostic radiation doses are also compared to the radiation doses received annually by man from natural background radiation. The controversy concerning the '10-day rule' in X-raying women of child-bearing age is discussed; it would appear that the risk of malformation in an unborn child due to X-radiation is very much less than the natural level of risk of malformation. The differences in the radiographic techniques and thus the different X-ray doses needed to make adequate X-ray images of different parts of the body are considered. The radiation burden of nuclear medicine investigations compared to X-ray procedures is also discussed. Finally, the problems of using volunteers in radiation research are aired.

  18. Diagnostics and structure

    International Nuclear Information System (INIS)

    Vial, J.C.

    1986-01-01

    The structure of prominences and the diagnostic techniques used to evaluate their physical parameters are discussed. These include electron temperature, various densities (n sub p, n sub e, n sub l), ionization degree, velocities, and magnetic field vector. UV and radio measurements have already evidenced the existence of different temperature regions, corresponding to different geometrical locations, e.g., the so called Prominence-Corona (P-C) interface. Velocity measurements are important for considering formation and mass balance of prominences but there are conflicting velocity measurements which have led to the basic question: what structure is actually observed at a given wavelength; what averaging is performed within the projected slit area during the exposure time? In optically thick lines, the question of the formation region of the radiation along the line of sight is also not a trivial one. The same is true for low resolution measurements of the magnetic field. Coupling diagnostics with structure is now a general preoccupation

  19. FEL components and diagnostics

    International Nuclear Information System (INIS)

    Carr, R.

    1997-01-01

    FEL hardware includes undulators, alignment systems, electron beam diagnostics, and mechanical and vacuum systems. While most FEL close-quote s employ conventional undulators, there is some interest in novel types, particularly where conventional designs cannot be used, as at very short periods and high fields. For these areas, superconducting technology is indicated. The most serious issue facing long FEL undulators is that of alignment; mechanical techniques may not be accurate enough, and beam-based strategies must be considered. To maintain alignment and control the electron trajectory, beam position monitors with micron precision are required. Beam size monitors are also required to assure control of emittance. The talks given in the working group sessions touch on undulators, alignment, and electron beam diagnostics, and they are summarized here. copyright 1997 American Institute of Physics

  20. Some theoretical problems of magnetic diagnostics in tokamaks and stellarators

    International Nuclear Information System (INIS)

    Pustovitov, V.D.

    1993-12-01

    The main problem of magnetic diagnostics is discussed here: which plasma characteristics can be determined from magnetic measurements in tokamaks and stellarators. The reasons are elucidated why diamagnetic measurements are reliable and easily interpreted. We discuss also the capabilities of diagnostics based on the measurements of poloidal fields outside the plasma. This article is based on a lecture delivered at the Third International School on Plasma Physics and Controlled Fusion, held 15-22 June 1993 at St. Petersburg - Kizhi, Russia. (author)

  1. Some theoretical problems of magnetic diagnostics in tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Pustovitov, V.D.

    1993-12-01

    The main problem of magnetic diagnostics is discussed here: which plasma characteristics can be determined from magnetic measurements in tokamaks and stellarators. The reasons are elucidated why diamagnetic measurements are reliable and easily interpreted. We discuss also the capabilities of diagnostics based on the measurements of poloidal fields outside the plasma. This article is based on a lecture delivered at the Third International School on Plasma Physics and Controlled Fusion, held 15-22 June 1993 at St. Petersburg - Kizhi, Russia. (author).

  2. STELLA Experiment - Microbunch Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    He, P.; Liu, Y.; Cline, D. B.; Babzien, M.; Gallardo, J. C.; Kusche, K. P.; Pogorelsky, I. V.; Skaritka, J.; van Steenbergen, A.; Yakimenko, V.; Kimura, W. D.

    1998-07-01

    A microbunch diagnostic system is built at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory for monitoring microbunches (10-fs bunch length) produced by the Inverse Free Electron Laser accelerator in Staged Electron Laser Acceleration experiment. It is similar to one already demonstrated at the ATF. With greatly improved beam optics conditions higher order harmonic coherent transition radiation will be measurable to determine the microbunch length and shape.

  3. Advanced diagnostic graphics

    International Nuclear Information System (INIS)

    Bray, M.A.; Petersen, R.J.; Clark, M.T.; Gertman, D.I.

    1981-01-01

    This paper reports US NRC-sponsored research at the Idaho National Engineering Laboratory (INEL) involving evaluation of computer-based diagnostic graphics. The specific targets of current evaluations are multivariate data display formats which may be used in Safety Parameter Display Systems (SPDS) being developed for nuclear power plant control rooms. The purpose of the work is to provide a basis for NRC action in regulating licensee SPDSs or later computer/cathode ray tube (CRT) applications in nuclear control rooms

  4. Molecular diagnostics in endodontics

    OpenAIRE

    Rechenberg, Dan-Krister; Zehnder, Matthias

    2014-01-01

    Recent systematic reviews have substantiated the fact that current testing methods to assess the inflammatory state of the pulp and the periapical tissues are of limited value. Consequently, it may be time to search for alternative routes in endodontic diagnostics. Molecular assessment methods could be the future. However, in the field of endodontics, the research in that direction is only about to evolve. Because pulpal and periradicular diseases are related to opportunistic infections, diag...

  5. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  6. RFQ1 diagnostic devices

    International Nuclear Information System (INIS)

    Chidley, B.G.; Arbique, G.M.; de Jong, M.S.; McMichael, G.E.; Michel, W.L.; Smith, B.H.

    1991-01-01

    The diagnostic devices in use on RFQ1 will be described. They consist of a double-slit emittance-measuring unit, a 45 degree deflection energy-analysis magnet, parametric current transformers, optical beam sensors, beam-stop current monitors, and an x-ray end-point analyzer. All of these devices are able to operate up to the full output current of RFQ1 (75 mA cw at 0.6 MeV)

  7. Idiopathic chondrolysis - diagnostic difficulties

    International Nuclear Information System (INIS)

    Kozlowski, K.; Scougall, J.; Royal Alexandra Hospital for Children, Sydney

    1984-01-01

    Four cases of idiopathic chondrolysis of the hip in three white girls and one Maori girl are reported. The authors stress the causes why a disease with characteristic clinical and radiographic appearances and normal biochemical findings presents diagnostic difficulties. It is suspected that idiopathic chondrolysis is a metabolic disorder of chondrocytes, triggered by environment circumstances in susceptible individuals. Idiopathic chondrolysis is probably one of the most common causes of coxarthrosis in women. (orig.)

  8. Radiological diagnostics in hyperparathyroidism

    International Nuclear Information System (INIS)

    Moedder, U.; Kuhn, F.P.; Gruetzner, G.

    1991-01-01

    The most important radiologically detectable effects of the primary and secondary hyperparathyroidism of the skeletal system and the periarticular soft tissue structures are presented. In the following sensitivity and specificity of radiological imaging - sonography, scintigraphy, computed tomography, magnetic resonance imaging, arteriography and selective venous sampling - in the preoperative diagnostic of the parathyroid adenomas are discussed. Therefore, radiological imaging can be omitted before primary surgery. It was only in secondary surgery that radiological process proved useful and a guide during surgical intervention. (orig.) [de

  9. Thioaptamer Diagnostic System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) will develop a diagnostic system in response to SBIR Topic X10.01 Reusable Diagnostic Lab Technology that will simultaneously detect and...

  10. Molecular diagnostics of periodontitis.

    Science.gov (United States)

    Korona-Głowniak, Izabela; Siwiec, Radosław; Berger, Marcin; Malm, Anna; Szymańska, Jolanta

    2017-01-28

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host's health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization) come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR), real-time polymerase chain reaction (real-time PCR), 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE), temperature gradient gel electrophoresis (TGGE), as well as terminal restriction fragment length polymorphism (TRFLP) and next generation sequencing (NGS). The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.

  11. Molecular diagnostics of periodontitis

    Directory of Open Access Journals (Sweden)

    Izabela Korona-Głowniak

    2017-01-01

    Full Text Available The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR, real-time polymerase chain reaction (real-time PCR, 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE, temperature gradient gel electrophoresis (TGGE, as well as terminal restriction fragment length polymorphism (TRFLP and next generation sequencing (NGS. The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.

  12. XML Diagnostics Description Standard

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Varandas, C.; Lister, J.; Yonekawa, I.

    2006-01-01

    A standard for the self-description of fusion plasma diagnostics will be presented, based on the Extensible Markup Language (XML). The motivation is to maintain and organise the information on all the components of a laboratory experiment, from the hardware to the access security, to save time and money when problems arises. Since there is no existing standard to organise this kind of information, every Association stores and organises each experiment in different ways. This can lead to severe problems when the organisation schema is poorly documented or written in national languages. The exchange of scientists, researchers and engineers between laboratories is a common practice nowadays. Sometimes they have to install new diagnostics or to update existing ones and frequently they lose a great deal of time trying to understand the currently installed system. The most common problems are: no documentation available; the person who understands it has left; documentation written in the national language. Standardisation is the key to solving all the problems mentioned. From the commercial information on the diagnostic (component supplier; component price) to the hardware description (component specifications; drawings) to the operation of the equipment (finite state machines) through change control (who changed what and when) and internationalisation (information at least in the native language and in English), a common XML schema will be proposed. This paper will also discuss an extension of these ideas to the self-description of ITER plant systems, since the problems will be identical. (author)

  13. SNS Diagnostics Timing Integration

    CERN Document Server

    Long, Cary D; Murphy, Darryl J; Pogge, James; Purcell, John D; Sundaram, Madhan

    2005-01-01

    The Spallation Neutron Source (SNS) accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The SNS diagnostics platform is PC-based running Windows XP Embedded for its OS and LabVIEW as its programming language. Coordinating timing among the various diagnostics instruments with the generation of the beam pulse is a challenging task that we have chosen to divide into three phases. First, timing was derived from VME based systems. In the second phase, described in this paper, timing pulses are generated by an in house designed PCI timing card installed in ten diagnostics PCs. Using fan-out modules, enough triggers were generated for all instruments. This paper describes how the Timing NAD (Network Attached Device) was rapidly developed using our NAD template, LabVIEW's PCI driver wizard, and LabVIEW Channel Access library. The NAD...

  14. Nuclear reaction data for IBA applications to cultural heritage diagnostics

    International Nuclear Information System (INIS)

    Maino, G.; Menapace, E.

    2008-01-01

    Main aspects are discussed concerning nuclear reaction cross-sections for PIXE and PIGE (Particle Induced Gamma-ray Emission) analyses, especially referring to cultural heritage diagnostics, within the framework of ion beam analysis (IBA) methods, also reviewing recent results from international Conferences on Nuclear Data for Science and Technology and from NEANSC meetings and IAEA initiatives on the matter.To sum up this work, it is then worth remarking the following items: IBA techniques are powerful tools to derive unique information as for corrosion, degradation and, generally, conservation conditions of materials. Careful analyses of specific systems require accurate evaluations and establishment of complete databases, in particular for stopping powers and relevant cross sections. The physical parameters to be accurately determined are, therefore, nuclear reaction cross sections of importance for NRA analysis of light elements and stopping powers and ranges of light and heavy ions in various matrices. Light elements (H, Li, B, C, N, O, etc.) play an important role as constituents of many important organic as well inorganic materials in historical and artistic objects. To a large extent these materials occur in the near-surface area of a material with altered or degraded composition

  15. Nuclear reaction data for IBA applications to cultural heritage diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Maino, G.; Menapace, E. [Bologna Univ., ENEA (Italy)

    2008-07-01

    Main aspects are discussed concerning nuclear reaction cross-sections for PIXE and PIGE (Particle Induced Gamma-ray Emission) analyses, especially referring to cultural heritage diagnostics, within the framework of ion beam analysis (IBA) methods, also reviewing recent results from international Conferences on Nuclear Data for Science and Technology and from NEANSC meetings and IAEA initiatives on the matter.To sum up this work, it is then worth remarking the following items: IBA techniques are powerful tools to derive unique information as for corrosion, degradation and, generally, conservation conditions of materials. Careful analyses of specific systems require accurate evaluations and establishment of complete databases, in particular for stopping powers and relevant cross sections. The physical parameters to be accurately determined are, therefore, nuclear reaction cross sections of importance for NRA analysis of light elements and stopping powers and ranges of light and heavy ions in various matrices. Light elements (H, Li, B, C, N, O, etc.) play an important role as constituents of many important organic as well inorganic materials in historical and artistic objects. To a large extent these materials occur in the near-surface area of a material with altered or degraded composition.

  16. Radiological diagnostics of skeletal tumors

    International Nuclear Information System (INIS)

    Uhl, M.; Herget, G.W.

    2008-01-01

    The book contains contributions concerning the following topics: 1. introduction and fundamentals: WHO classification of bone tumors, imaging diagnostics and their function; localization, typical clinical and radiological criteria, TNM classification and status classification, invasive tumor diagnostics; 2. specific tumor diagnostics: chondrogenic bone tumors, osseous tumors, connective tissue bony tumors, osteoclastoma, osteomyelogenic bone tumors, vascular bone tumors, neurogenic bone tumors, chordoma; adamantinoma of the long tubular bone; tumor-like lesions, bony metastases, bone granulomas, differential diagnostics: tumor-like lesions

  17. Bringing diagnostics to developing countries: an interview with Rosanna Peeling.

    Science.gov (United States)

    Peeling, Rosanna

    2015-01-01

    Interview with Professor Rosanna Peeling, PhD by Claire Raison (Commissioning Editor) Professor Rosanna Peeling is Chair of Diagnostic Research at the London School of Hygiene and Tropical Medicine (London, UK) and founded the International Diagnostics Centre at the institution. Professor Peeling previously worked for the WHO in Geneva, Switzerland, and continues to work on innovations for molecular diagnostics for point-of-care use in developing countries, addressing challenges posed by lack of funding and resources, regulatory issues and under-developed healthcare systems in these locations. Here, she discusses her career, recent progress in the field and how connectivity will affect global healthcare.

  18. Sintering of composite

    International Nuclear Information System (INIS)

    Bordia, R.K.; Scherer, G.W.

    1988-01-01

    Several constitutive laws have been used in the literature to predict the response of sintering bodies under external and internal stress fields. These analyses are based on the assumptions of linear and isotropic behavior. The authors provide a critical examination of these equations and show that some of the available constitutive laws predict a negative Poisson's ratio. These laws have been used to analyze sintering of ceramic matrix composites with rigid inclusions and predict large values of the internal stresses and significant retardation of the densification of composites. Since a negative value of Poisson's ratio has never been observed in sinter - forging experiments, the authors conclude that either the stresses are small (as predicted by the constitutive laws with positive Poisson's ratio) or the basic assumption of linearity and isotropy used in all the analyses is incorrect. Finally, the authors discuss some phenomena that could be important in understanding the densification of ceramic matrix composites

  19. Real time PV manufacturing diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Kochergin, Vladimir [MicroXact Inc., Blacksburg, VA (United States); Crawford, Michael A. [MicroXact Inc., Blacksburg, VA (United States)

    2015-09-01

    The main obstacle Photovoltaic (PV) industry is facing at present is the higher cost of PV energy compared to that of fossil energy. While solar cell efficiencies continue to make incremental gains these improvements are so far insufficient to drive PV costs down to match that of fossil energy. Improved in-line diagnostics however, has the potential to significantly increase the productivity and reduce cost by improving the yield of the process. On this Phase I/Phase II SBIR project MicroXact developed and demonstrated at CIGS pilot manufacturing line a high-throughput in-line PV manufacturing diagnostic system, which was verified to provide fast and accurate data on the spatial uniformity of thickness, an composition of the thin films comprising the solar cell as the solar cell is processed reel-to-reel. In Phase II project MicroXact developed a stand-alone system prototype and demonstrated the following technical characteristics: 1) ability of real time defect/composition inconsistency detection over 60cm wide web at web speeds up to 3m/minute; 2) Better than 1mm spatial resolution on 60cm wide web; 3) an average better than 20nm spectral resolution resulting in more than sufficient sensitivity to composition imperfections (copper-rich and copper-poor regions were detected). The system was verified to be high vacuum compatible. Phase II results completely validated both technical and economic feasibility of the proposed concept. MicroXact’s solution is an enabling technique for in-line PV manufacturing diagnostics to increase the productivity of PV manufacturing lines and reduce the cost of solar energy, thus reducing the US dependency on foreign oil while simultaneously reducing emission of greenhouse gasses.

  20. The architecture of diagnostic research

    DEFF Research Database (Denmark)

    Colli, Agostino; Fraquelli, Mirella; Casazza, Giovanni

    2014-01-01

    The diagnostic research process can be divided into five phases, designed to establish the clinical utility of a new diagnostic test - the index test. The aim of the present review is to illustrate the study designs that are appropriate for each diagnostic phase, using clinical examples regarding...

  1. Exposure to Indian population from diagnostic radiology

    International Nuclear Information System (INIS)

    Supe, S.J.; Venkataraman, G.; Sasane, J.B.; Sawant, S.G.; Shirva, V.K.; Iyer, P.S.

    1993-01-01

    Many national and international agencies are actively engaged in taking stock of radiation safety status of radiation procedures which add to the population dose significantly. National survey is being conducted to collect data from various diagnostic X-ray institutions to assess radiation safety status and population dose arising from such practices in India. For this purpose 11 centres are collecting information on annual number of patients examined site wise and on their age and sex distribution. Patient doses are also measured for various diagnostic X-ray examinations in a few hospitals using CaSO 4 :Dy TLD dosimeters. Preliminary results of earlier study indicate that the country has about 50000 diagnostic X-ray units. The annual number of X-ray examinations is estimated to be 9x10 7 . Mean entrance skin dose for diagnostic X-rays are between 0.2 to 50 mGy depending on the type of examination. On the basis of experience gained in the earlier survey an exhaustive survey is undertaken for 1992-93 for improving the assessment of population dose. (author). 3 refs

  2. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Sasao, M.; Krasilnikov, A.V.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Jarvis, O.N.; Iguchi, T.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be well measured by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include: radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors, neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The neutron flux monitors need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented. (author)

  3. Status of ITER neutron diagnostic development

    Science.gov (United States)

    Krasilnikov, A. V.; Sasao, M.; Kaschuck, Yu. A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V. S.; Popovichev, S.; Iguchi, T.; Jarvis, O. N.; Källne, J.; Fiore, C. L.; Roquemore, A. L.; Heidbrink, W. W.; Fisher, R.; Gorini, G.; Prosvirin, D. V.; Tsutskikh, A. Yu.; Donné, A. J. H.; Costley, A. E.; Walker, C. I.

    2005-12-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented.

  4. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Krasilnikov, A.V.; Sasao, M.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Iguchi, T.; Jarvis, O.N.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Prosvirin, D.V.; Tsutskikh, A.Yu.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented

  5. Effect of respiratory motion on internal radiation dosimetry

    NARCIS (Netherlands)

    Xie, Tianwu; Zaidi, Habib

    2014-01-01

    Purpose: Estimation of the radiation dose to internal organs is essential for the assessment of radiation risks and benefits to patients undergoing diagnostic and therapeutic nuclear medicine procedures including PET. Respiratory motion induces notable internal organ displacement, which influences

  6. Internal friction and longitudinal modulus behaviour of multiferroic PbZr0.52Ti0.48O3+Ni0.93Co0.02Mn0.05Fe1.95O4-δ particulate composites

    International Nuclear Information System (INIS)

    Ramana, M Venkata; Sreenivasulu, G; Reddy, N Ramamanohar; Kumar, K V Siva; Murty, B S; Murthy, V R K

    2007-01-01

    Multiferroic particulate composites with composition xNi 0.93 Co 0.02 Mn 0.5 Fe 1.95 O 4-δ + (1 - x)PbZr 0.52 Ti 0.48 O 3 where the molar fraction x varies as 0, 0.1, 0.2, 0.3, 0.4 and 0.5 were prepared by the conventional ceramic method. The presence of two phases was confirmed by x-ray diffraction and scanning electron microscopy. The temperature variation of the longitudinal modulus (L) and the internal friction (Q -1 ) of these particulate composites at 104.387 kHz was studied in the wide temperature range 30-420 deg. C. The temperature variation of the longitudinal modulus (L) in each composition of these particulate composites showed two abrupt minima. One minimum coincided with the ferroelectric-paraelectric Curie transition temperature (θ E ) and the other with the ferrimagnetic-paramagnetic Curie transition (θ M ) temperature. The internal friction (Q -1 ) measurements also showed two sharp peaks in each composition corresponding to those temperatures where the minima were noticed in the temperature variation of the longitudinal modulus behaviour. The Curie transition temperature of pure ferrite was found to be 560 deg. C. Addition of 10% of ferrite to ferroelectric in a magnetoelectric (ME) composite resulted in a 360 deg. C fall in θ M and with a further increase in ferrite content the θ M variation was found to be very nominal. However, no significant ferroelectric Curie transition temperature shift could be noticed. This behaviour is explained in the light of structural phase transitions in these multiferroic particulate composites. These ME composites were prepared with a view to using them as ME sensors and transducers

  7. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    Science.gov (United States)

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  8. Limitations of typhoid fever diagnostics and the need for prevention

    NARCIS (Netherlands)

    Smits, Henk L.

    2013-01-01

    Evaluation of: Siba V, Horwood PF, Vanuga K et al. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard. Clin. Vaccine Immunol. 19(11), 1833-1837 (2012). The study under review evaluated serological tests for typhoid fever against PCR

  9. PLASMA-2005: International Conference on Research and Applications of Plasmas combined with the 3. German-Polish Conference on Plasma Diagnostics for Fusion and Applications and the 5. French-Polish Seminar on Thermal Plasma in Space and Laboratory. Book of Abstracts

    International Nuclear Information System (INIS)

    Ksiazek, K.

    2005-01-01

    The International Conferences 'PLASMA' have been organized in Poland every two years since 1993. The German-Polish Conferences on Plasma Diagnostics were started in 2002, and the French-Polish Seminars on Thermal Plasmas were initiated in 1997. To reduce a number of topical conferences and to improve an exchange of information among different plasma research groups it was agreed to organize for the first time the triple conference at the Opole University, Poland, on September 6-9, 2005. The chairman of the International Scientific Committee (ISC) was Professor Marek J. Sadowski from IPJ in Swierk, and the co-chairmen were Professor Thomas Klinger of the IPP-Greifswald and Professor Michel Dudeck of the CNRS-Orleans. The chairman of LOC was Professor Jozef Musielok of the Opole University. This conference was designed for interested scientists, engineers and students from all the countries, but particularly for these from the Central and Eastern Europe (see http://draco.uni.opole.pl/plasma2005). The scientific programme of the conference embraced almost all directions of plasma research and technology, i.e.: 1. Elementary processes and general theory of plasma; 2. Plasmas in tokamaks, stellerators and related experiments; 3. plasmas in Z-pinch and PF discharges; 4. Plasmas produced by intense laser beams; 5. Plasmas of micro-wave and glow discharges; 6. Plasmas in spark- and arc-discharges; 7. Plasmas in space; 8. Diagnostics and experimental facilities; 9. Applications of quasi-stationary and pulsed plasmas. Participants of the conference were 127 plasma experts (including 23 invited speakers) from 13 different countries, as well as several honorary guests from local authorities and the most important plasma research centers in Poland. Most numerous groups came from Poland (58 persons), Germany (15 persons), France (14 persons), Czech Republic (11 persons), Russia (7 persons), and Ukraine (6 persons). The participants came also from Belarus, Hungary, Iran, Japan

  10. Diagnostic imaging in medicine. 2. ed.

    International Nuclear Information System (INIS)

    Reba, R.C.; Goodenough, D.J.

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume. (orig.)

  11. Diagnostic imaging in medicine. 2nd ed

    Energy Technology Data Exchange (ETDEWEB)

    Reba, R C; Goodenough, D J; Davidson, H F

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume.

  12. Influence diagnostics in meta-regression model.

    Science.gov (United States)

    Shi, Lei; Zuo, ShanShan; Yu, Dalei; Zhou, Xiaohua

    2017-09-01

    This paper studies the influence diagnostics in meta-regression model including case deletion diagnostic and local influence analysis. We derive the subset deletion formulae for the estimation of regression coefficient and heterogeneity variance and obtain the corresponding influence measures. The DerSimonian and Laird estimation and maximum likelihood estimation methods in meta-regression are considered, respectively, to derive the results. Internal and external residual and leverage measure are defined. The local influence analysis based on case-weights perturbation scheme, responses perturbation scheme, covariate perturbation scheme, and within-variance perturbation scheme are explored. We introduce a method by simultaneous perturbing responses, covariate, and within-variance to obtain the local influence measure, which has an advantage of capable to compare the influence magnitude of influential studies from different perturbations. An example is used to illustrate the proposed methodology. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Diagnostics, therapy and ecology of thyroid diseases

    International Nuclear Information System (INIS)

    Stieve, F.E.; Roedler, H.D.

    1983-01-01

    Topical problems concerning diagnostics, therapy and ecology of thyroid diseases were discussed on an international level at this symposium. As the problems are mostly medical in nature, the symposium started with papers on the anatomy, physiology, and pathology of the thyroid, followed by lectures on dose calculation and dose/effect relationships. Particular attention is paid to the distinction between external radiation exposure and incorporation of radioactive materials, especially iodine. Another section of the symposium was dedicated to the establishment of radiation hazards. The symposium ended with a discussion of the value of diagnostic and therapeutical procedures. The extensive discussions between experts from different nations and different fields of science have surely helped to deepen the knowledge on radiation effects. (orig./MG) [de

  14. Planetary Transmission Diagnostics

    Science.gov (United States)

    Lewicki, David G. (Technical Monitor); Samuel, Paul D.; Conroy, Joseph K.; Pines, Darryll J.

    2004-01-01

    This report presents a methodology for detecting and diagnosing gear faults in the planetary stage of a helicopter transmission. This diagnostic technique is based on the constrained adaptive lifting algorithm. The lifting scheme, developed by Wim Sweldens of Bell Labs, is a time domain, prediction-error realization of the wavelet transform that allows for greater flexibility in the construction of wavelet bases. Classic lifting analyzes a given signal using wavelets derived from a single fundamental basis function. A number of researchers have proposed techniques for adding adaptivity to the lifting scheme, allowing the transform to choose from a set of fundamental bases the basis that best fits the signal. This characteristic is desirable for gear diagnostics as it allows the technique to tailor itself to a specific transmission by selecting a set of wavelets that best represent vibration signals obtained while the gearbox is operating under healthy-state conditions. However, constraints on certain basis characteristics are necessary to enhance the detection of local wave-form changes caused by certain types of gear damage. The proposed methodology analyzes individual tooth-mesh waveforms from a healthy-state gearbox vibration signal that was generated using the vibration separation (synchronous signal-averaging) algorithm. Each waveform is separated into analysis domains using zeros of its slope and curvature. The bases selected in each analysis domain are chosen to minimize the prediction error, and constrained to have the same-sign local slope and curvature as the original signal. The resulting set of bases is used to analyze future-state vibration signals and the lifting prediction error is inspected. The constraints allow the transform to effectively adapt to global amplitude changes, yielding small prediction errors. However, local wave-form changes associated with certain types of gear damage are poorly adapted, causing a significant change in the

  15. Wood composites

    Science.gov (United States)

    Lars Berglund; Roger M. Rowell

    2005-01-01

    A composite can be defined as two or more elements held together by a matrix. By this definition, what we call “solid wood” is a composite. Solid wood is a three-dimensional composite composed of cellulose, hemicelluloses and lignin (with smaller amounts of inorganics and extractives), held together by a lignin matrix. The advantages of developing wood composites are (...

  16. Biotechnology in diagnostics

    International Nuclear Information System (INIS)

    Koprowski, H.; Ferrone, S.; Albertini, A.

    1985-01-01

    In recent years much progress has been made in the area of biotechnology. The cellular and molecular cloning methodology to develop monoclonal antibodies and DNA probes have been extensively utilized in basic and clinical research. These investigations have provided the necessary information to apply these reagents to diagnostic problems. The RIA 85 meeting focused on the application of monoclonal antibodies and DNA probes in laboratory medicine. The papers presented at this meeting clearly indicate that biotechnology has already had a significant impact on clinical medicine. (Auth.)

  17. Bouveret's Syndrome: diagnostic considerations

    International Nuclear Information System (INIS)

    Cooper, S.G.; Sherman, S.B.; Steinhardt, J.E.; Wilson, J.M. Jr.; Richman, A.H.

    1987-01-01

    Bouveret's syndrome is a rare disease entity manifested by the formation of a cholecystoduodenal or choledochoduodenal fistula with passage of a gallstone into the duodenal bulb and subsequent obstruction of the gastric outlet. To date, no report of this entity using computed tomographic (CT) imaging is available. This article presents a case of Bouveret's syndrome with the classic findings on upper gastrointestinal (GI) tract series and a description of the CT manifestations. The literature is reviewed with discussion of the diagnostic approach to patients with Bouveret's syndrome

  18. FASTBUS Snoop Diagnostic Module

    International Nuclear Information System (INIS)

    Walz, H.V.; Downing, R.

    1980-11-01

    Development of the FASTBUS Snoop Module, undertaken as part of the prototype program for the new interlaboratory data bus standard, is described. The Snoop Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. Communication with a remote host computer is handled independent of FASTBUS through a serial link. The module consists of a high-speed ECL front-end to monitor and single-step FASTBUS cycles, a master-slave interface, and a control microprocessor with serial communication ports. Design details and performance specifications of the prototype module are reported. 9 figures, 1 table

  19. Isotope diagnostics apparatus

    International Nuclear Information System (INIS)

    Herrschaft, H.

    1976-01-01

    The invention relates to a measuring probe for an isotope diagnostics apparatus to determine the distribution of radioactive substances in a body by measuring the radiation emanating from this body by means of a multiplicity of measuring probes directed simultaneously towards areas of measuring surfae and carried in guidances of a holding block. The measuring results of the individual probes are recorded separately, thus allowing the possibility of being evaluated separately, too. Measuring probes of this kind are used in multi-channel measuring objects and are useful particularly for determining the regional cerebral blood flow. (orig./ORU) [de

  20. Vibration control, machine diagnostics

    International Nuclear Information System (INIS)

    1990-01-01

    Changing vibrations announce damage in the form of wear or cracks on components of, e.g., engine rotors, pumps, power plant turbo sets, rounding-up tools, or marine diesel engines. Therefore, machine diagnostics use frequency analyses, system tests, trend analyses as well as expert systems to localize or estimate the causes of these damages and malfunctions. Data acquisistion, including not only sensors, but also reliable and redundant data processing systems and analyzing systems, play an important role. The lectures pertaining to the data base are covered in detail. (DG) [de

  1. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  2. Nuclear power plant diagnostics

    International Nuclear Information System (INIS)

    Hollo, E.; Siklossy, P.

    1982-01-01

    The cooling circuit vibration diagnostic system of the Block 1 of the Paks nuclear power station is described. The automatic online vibration monitoring system consisting presently of 42 acceleration sensors and 9 pressure fluctuation sensors, which could be extended, performs both global and local inspection of the primary cooling circuit and its components. The offline data processing system evaluates the data for failure mode analysis. The software under development will be appropriate for partial preliminary identification of failure reasons during their initial phases. The installation experiences and the preliminary results during the hot operational testing of Block 1 are presented. (Sz.J.)

  3. Thermal diagnostics for LTP

    International Nuclear Information System (INIS)

    Lobo, Alberto; Nofrarias, M; Sanjuan, J

    2005-01-01

    This is a short note reporting on the current state of development of the temperature sensors which are part of the LTP Diagnostics Subsystem on board the LISA Pathfinder mission (LPF). A thermal insulator has been designed which ensures sufficient stability of a set of eight NTC sensors (negative temperature coefficient of resistance or thermistors), and the front-end electronics has also been designed and manufactured. Tests have been performed which nearly approach the goal of a global stability of 10 -5 K Hz -1/2

  4. Physics R and D in support of ITER/BPX diagnostic development

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Boivin, R.; Costley, A.E.

    2003-01-01

    The development of diagnostics for a next step burning plasma experiment (BPX) is a major challenge. Within the International Tokamak Physics Activity (ITPA), one Topical Group (TG) specialises in diagnostics and aims to support the development and design of the needed systems. Several diagnostics issues have been identified as 'high priority' and form the focus of current work of the TG. The core of this paper is a presentation and discussion of recent progress in the field of these high priority research topics. Moreover, the status of the recently initiated International Diagnostic Database will be briefly described. (author)

  5. Structure of diagnostics horizons and humus classification

    Directory of Open Access Journals (Sweden)

    Zanella A

    2008-03-01

    Full Text Available The classification of the main humus forms is generally based on the morpho-genetic characters of the A and OH diagnostic horizons. This is the case in the new European key of classification presented in Freiburg on September 2004 (Eurosoil Congress. Among the morpho-genetic characters, the soil structure covers a very important role. In this work, the structure of the diagnostic A and OH horizons has been analysed in terms of aggregation force, diameter and composition of the soil lumps (peds. In order to study the aggregation force, two disaggregating tools have been conceived and used. The diameter of the lumps has been measured by sieving the soil samples with standardised webs. Observing the samples thanks to a binocular magnifying 10X and 50X, the organic or/and mineral composition of the soil aggregates has been determined, data being investigated with ANOVA and Factorial Analysis. The article examines the argument from two points of view: crashing tools for estimating the soil structure (part 1 and the dimensions of the peds given in European key of humus forms classification (part 2. The categories of soil peds diameter and composition seem to be linked to the main humus forms. For instance, aggregates having a diamater larger than 1 mm and well amalgamate organo-mineral composition are more present in the A horizons of the Mull forms than in which of the other forms; contrary to the OH horizon of the Moder or Mor, the OH horizon of the Amphi forms shows an important percent of small organic lumps. Some propositions have been given in order to improve the European key of humus forms classification.

  6. Communication skills in diagnostic pathology.

    Science.gov (United States)

    Lehr, Hans-Anton; Bosman, Fred T

    2016-01-01

    Communication is an essential element of good medical practice also in pathology. In contrast to technical or diagnostic skills, communication skills are not easy to define, teach, or assess. Rules almost do not exist. In this paper, which has a rather personal character and cannot be taken as a set of guidelines, important aspects of communication in pathology are explored. This includes what should be communicated to the pathologist on the pathology request form, communication between pathologists during internal (interpathologist) consultation, communication around frozen section diagnoses, modalities of communication of a final diagnosis, with whom and how critical and unexpected findings should be communicated, (in-)adequate routes of communication for pathology diagnoses, who will (or might) receive pathology reports, and what should be communicated and how in case of an error or a technical problem. An earlier more formal description of what the responsibilities are of a pathologist as communicator and as collaborator in a medical team is added in separate tables. The intention of the paper is to stimulate reflection and discussion rather than to formulate strict rules.

  7. International Year of Pulses 2016 | 2016 International Year of Pulses

    Science.gov (United States)

    the Year in collaboration with Governments, relevant organizations, non-governmental organizations and the composition of pulses Image 4 Wrapping up the International Year of Pulses The 5 key messages to food security Infographic Pulses and climate change International Year of Pulses 2016 The 68th UN

  8. Diagnostic Technologies in Practice

    Science.gov (United States)

    Steinberg, Malcolm; Kwag, Michael; Chown, Sarah A.; Doupe, Glenn; Trussler, Terry; Rekart, Michael; Gilbert, Mark

    2015-01-01

    Diagnosing HIV-positive gay men through enhanced testing technologies that detect acute HIV infection (AHI) or recent HIV infection provides opportunities for individual and population health benefits. We recruited 25 men in British Columbia who received an acute (n = 13) or recent (n = 12) HIV diagnosis to engage in a longitudinal multiple-methods study over one year or longer. Our thematic analysis of baseline qualitative interviews revealed insights within men’s accounts of technologically mediated processes of HIV discovery and diagnosis. Our analysis illuminated the dialectic of new HIV technologies in practice by considering the relationship between advances in diagnostics (e.g., nucleic acid amplification tests) and the users of these medical technologies in clinical settings (e.g., clients and practitioners). Technological innovations and testing protocols have shifted experiences of learning of one’s HIV-positive status; these innovations have created new diagnostic categories that require successful interpretation and translation to be rendered meaningful, to alleviate uncertainty, and to support public health objectives. PMID:25201583

  9. Shiva optical diagnostics

    International Nuclear Information System (INIS)

    Rienecker, F.; Kobierecki, M.; Ozarski, R.; Seppala, L.; Manes, K.; Merritt, B.

    1977-01-01

    In the laser fusion program at Lawrence Livermore Laboratory, no target experiment is complete unless it is complemented by careful measurements of the laser pulse that irradiates the target. For this purpose, an incident beam diagnostics (IBD) package has been designed for the Shiva laser. The package will furnish data on items such as the total energy and the focusable energy out of the laser chain, and the spatial and temporal energy and power distribution at the target plane. Understanding laser-plasma interactions requires knowledge of the amount of 1.06 μm light energy that is scattered in various directions from the target. The light energy that is scattered toward the beam focusing lens is analyzed by a reflected beam diagnostic (RBD) package containing a calorimeter, a multiple image camera and a TV camera. This paper describes the detailed design and operation of the IBD and RBD packages as tools to align spatial filters and targets, as well as to diagnose the laser beams and target reflectivity

  10. Laser fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1978-01-01

    The current status of the capability of laser fusion diagnostics is reviewed. Optical and infrared streak cameras provide one time resolution measurement capability of less than 10 ps, while x-ray streak cameras provide 15 ps time resolution in the range of about 1--30 keV presently. Time integrated spatial resolutions of 1 μm are provided with a variety of optical techniques. Ultraviolet holographic interferometry has measured electron densities above 10 21 cm -3 with 1 μm spatial resolution and 15 ps temporal resolution. X-ray microscopes provide 3 μm time integrated resolution and the x-ray streak pinhole camera has 6 μm spatial resolution. Development of the framing camera has thus far provided 50 μm spatial resolution with 125 ps frame duration and the third order reconstruction of zone plate images has provided 3 μm resolutions for alpha particles. Time integrated measurements of x-rays span the range shown. Finally, the new Shiva neutron spectrometer increases the energy resolution capability of that technique to 25 keV for 14-MeV neutrons. These combined capabilities provide a unique set of diagnostics for the detailed measurement of the interaction of laser light with targets and a subsequent performance of those targets

  11. Reflectometry diagnostics on TCV

    Science.gov (United States)

    Molina Cabrera, Pedro; Coda, Stefano; Porte, Laurie; Offeddu, Nicola; Tcv Team

    2017-10-01

    Both profile reflectometer and Doppler back-scattering (DBS) diagnostics are being developed for the TCV Tokamak using a steerable quasi-optical launcher and universal polarizers. First results will be presented. A pulse reflectometer is being developed to complement Thomson Scattering measurements of electron density, greatly increasing temporal resolution and also effectively enabling fluctuation measurements. Pulse reflectometry consists of sending short pulses of varying frequency and measuring the roundtrip group-delay with precise chronometers. A fast arbitrary waveform generator is used as a pulse source feeding frequency multipliers that bring the pulses to V-band. A DBS diagnostic is currently operational in TCV. DBS may be used to infer the perpendicular velocity and wave number spectrum of electron density fluctuations in the 3-15 cm-1 wave-number range. Off-the-shelf transceiver modules, originally used for VNA measurements, are being used in a Doppler radar configuration. See author list of S. Coda et al., 2017 Nucl. Fusion 57 102011.

  12. Radiation hardening of diagnostics

    International Nuclear Information System (INIS)

    Siemon, R.E.

    1991-01-01

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10 16 neutrons per second because of ''spallation'' reactions when the protons collide with the copper nuclei in the beam stop

  13. Climate Model Diagnostic Analyzer

    Science.gov (United States)

    Lee, Seungwon; Pan, Lei; Zhai, Chengxing; Tang, Benyang; Kubar, Terry; Zhang, Zia; Wang, Wei

    2015-01-01

    The comprehensive and innovative evaluation of climate models with newly available global observations is critically needed for the improvement of climate model current-state representation and future-state predictability. A climate model diagnostic evaluation process requires physics-based multi-variable analyses that typically involve large-volume and heterogeneous datasets, making them both computation- and data-intensive. With an exploratory nature of climate data analyses and an explosive growth of datasets and service tools, scientists are struggling to keep track of their datasets, tools, and execution/study history, let alone sharing them with others. In response, we have developed a cloud-enabled, provenance-supported, web-service system called Climate Model Diagnostic Analyzer (CMDA). CMDA enables the physics-based, multivariable model performance evaluations and diagnoses through the comprehensive and synergistic use of multiple observational data, reanalysis data, and model outputs. At the same time, CMDA provides a crowd-sourcing space where scientists can organize their work efficiently and share their work with others. CMDA is empowered by many current state-of-the-art software packages in web service, provenance, and semantic search.

  14. Thioaptamer Diagnostic System (TDS)

    Science.gov (United States)

    Yang, Xianbin

    2015-01-01

    AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.

  15. Encyclopedia of diagnostic imaging

    International Nuclear Information System (INIS)

    Baert, A.L.

    2008-01-01

    The simple A to Z format provides easy access to relevant information in the field of imaging. Extensive cross references between keywords and related articles enable efficient searches in a user-friendly manner. Fully searchable and hyperlinked electronic online edition. The aim of this comprehensive encyclopedia is to provide detailed information on diagnostic radiology contributing to the broad field of imaging. The wide range of entries are written by leading experts. They will provide basic and clinical scientists in academia, practice and industry with valuable information about the field of diagnostic imaging. Those in related fields, students, teachers, and interested laypeople will also benefit from the important and relevant information on the most recent developments. Please note that this publication is available as print only or online only or print + online set. Save 75% of the online list price when purchasing the bundle. For more information on the online version please type the publication title into the search box above, then click on the eReference version in the results list. (orig.)

  16. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  17. Edge diagnostics for tandem mirror machines

    International Nuclear Information System (INIS)

    Allen, S.L.

    1984-01-01

    The edge plasma in a tandem mirror machine shields the plasma core from cold neutral gas and impurities. A variety of diagnostics are used to measure the fueling, shielding, and confinement of the edge plasma in both the end plug and central cell regions. Fast ion gauges and residual gas analyzers measure the gas pressure and composition outside of the plasma. An array of Langmuir probes is used to measure the electron density and temperature. Extreme ultraviolet (euv) and visible spectroscopy are used to measure both the impurity and deuterium densities and to estimate the shielding factor for the core plasma. The linear geometry of a tandem mirror also allows direct measurements of the edge plasma by sampling the ions and electrons lost but the ends of the machine. Representative data obtained by these diagnostics during operation of the Tandem Mirror Experiment (TMX) and Tandem Mirror Experiment-Upgrade (TMX-U) experiments are presented. Diagnostics that are currently being developed to diagnose the edge plasma are also discussed

  18. Sixth meeting of the ITPA Topical Group on Diagnostics

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Costley, A.E.

    2004-01-01

    The Sixth Meeting of the International Tokamak Physics Activities (ITPA) Topical Group (TG) on Diagnostics was held at JAERI, Naka from 19-21 February 2004. This meeting was combined with a Progress Meeting on ITER/BPX (burning plasma experiment) relevant diagnostic developments on-going in Japan. For the first time, ITPA members from China, as well as observers from South Korea, attended. In addition, an associated sub-meeting was held at General Atomics, San Diego, 23-24 April, immediately after the 15th Topical Conference on High Temperature Plasma Diagnostics. At the sub-meeting a special one-day session was devoted to issues related to beam-aided spectroscopy. In total more than 50 participants attended the meetings and all ITER partners were represented. The key topics reviewed and discussed at the TG meeting were: (i) the overall status of diagnostics developments for ITER, (ii) the progress in the research on the designated high priority topics, (iii) the progress with some key ITER/BPX-relevant diagnostic developments ongoing in the ITPA participant laboratories, (iv) the progress and plans for the work of the specialist working groups, (v) the status and plans for the International Diagnostic Database

  19. Plasma diagnostics on large tokamaks

    International Nuclear Information System (INIS)

    Orlinskij, D.V.; Magyar, G.

    1988-01-01

    The main tasks of the large tokamaks which are under construction (T-15 and Tore Supra) and of those which have already been built (TFTR, JET, JT-60 and DIII-D) together with their design features which are relevant to plasma diagnostics are briefly discussed. The structural features and principal characteristics of the diagnostic systems being developed or already being used on these devices are also examined. The different diagnostic methods are described according to the physical quantities to be measured: electric and magnetic diagnostics, measurements of electron density, electron temperature, the ion components of the plasma, radiation loss measurements, spectroscopy of impurities, edge diagnostics and study of plasma stability. The main parameters of the various diagnostic systems used on the six large tokamaks are summarized in tables. (author). 351 refs, 44 figs, 22 tabs

  20. Cognitive aspect of diagnostic errors.

    Science.gov (United States)

    Phua, Dong Haur; Tan, Nigel C K

    2013-01-01

    Diagnostic errors can result in tangible harm to patients. Despite our advances in medicine, the mental processes required to make a diagnosis exhibits shortcomings, causing diagnostic errors. Cognitive factors are found to be an important cause of diagnostic errors. With new understanding from psychology and social sciences, clinical medicine is now beginning to appreciate that our clinical reasoning can take the form of analytical reasoning or heuristics. Different factors like cognitive biases and affective influences can also impel unwary clinicians to make diagnostic errors. Various strategies have been proposed to reduce the effect of cognitive biases and affective influences when clinicians make diagnoses; however evidence for the efficacy of these methods is still sparse. This paper aims to introduce the reader to the cognitive aspect of diagnostic errors, in the hope that clinicians can use this knowledge to improve diagnostic accuracy and patient outcomes.