WorldWideScience

Sample records for composite international diagnostic

  1. Negative and positive participant responses to the composite international diagnostic interview - Results of the Netherlands Mental Health Survey and Incidence Study

    NARCIS (Netherlands)

    Graaf, R. de; Have, M.L. ten; Dorsselaer, S.A.F.M. van; Schoemaker, C.G.; Vollebergh, W.A.M.

    2004-01-01

    Little is known about the emotional responses of participants in community surveys to standardised psychiatric interviews like the Composite International Diagnostic Interview (CIDI). This study investigates the proportion of subjects responding negatively or positively to the CIDI, and identifies

  2. Validity of Chinese Version of the Composite International Diagnostic Interview-3.0 in Psychiatric Settings

    Institute of Scientific and Technical Information of China (English)

    Jin Lu; Yue-Qin Huang; Zhao-Rui Liu; Xiao-Lan Cao

    2015-01-01

    Background:The Composite International Diagnostic Interview-3.0 (CIDI-3.0) is a fully structured lay-administered diagnostic interview for the assessment of mental disorders according to ICD-10 and Diagnostic and Statistical Manual of Mental Disorders,Fourth Edition (DSM-Ⅳ) criteria.The aim of the study was to investigate the concurrent validity of the Chinese CIDI in diagnosing mental disorders in psychiatric settings.Methods:We recruited 208 participants,of whom 148 were patients from two psychiatric hospitals and 60 healthy people from communities.These participants were administered with CIDI by six trained lay interviewers and the Structured Clinical Interview for DSM-Ⅳ Axis I Disorders (SCID-I,gold standard) by two psychiatrists.Agreement between CIDI and SCID-I was assessed with sensitivity,specificity,positive predictive value and negative predictive value.Individual-level CIDI-SCID diagnostic concordance was evaluated using the area under the receiver operator characteristic curve and Cohen's K.Results:Substantial to excellent CIDI to SCID concordance was found for any substance use disorder (area under the receiver operator characteristic curve [AUC] =0.926),any anxiety disorder (AUC =0.807) and any mood disorder (AUC =0.806).The concordance between the CIDI and the SCID for psychotic and eating disorders is moderate.However,for individual mental disorders,the CIDI-SCID concordance for bipolar disorders (AUC =0.55) and anorexia nervosa (AUC =0.50) was insufficient.Conclusions:Overall,the Chinese version of CIDI-3.0 has acceptable validity in diagnosing the substance use disorder,anxiety disorder and mood disorder among Chinese adult population.However,we should be cautious when using it for bipolar disorders and anorexia nervosa.

  3. Validity of Chinese Version of the Composite International Diagnostic Interview-3.0 in Psychiatric Settings

    Directory of Open Access Journals (Sweden)

    Jin Lu

    2015-01-01

    Full Text Available Background: The Composite International Diagnostic Interview-3.0 (CIDI-3.0 is a fully structured lay-administered diagnostic interview for the assessment of mental disorders according to ICD-10 and Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV criteria. The aim of the study was to investigate the concurrent validity of the Chinese CIDI in diagnosing mental disorders in psychiatric settings. Methods: We recruited 208 participants, of whom 148 were patients from two psychiatric hospitals and 60 healthy people from communities. These participants were administered with CIDI by six trained lay interviewers and the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I, gold standard by two psychiatrists. Agreement between CIDI and SCID-I was assessed with sensitivity, specificity, positive predictive value and negative predictive value. Individual-level CIDI-SCID diagnostic concordance was evaluated using the area under the receiver operator characteristic curve and Cohen′s K. Results: Substantial to excellent CIDI to SCID concordance was found for any substance use disorder (area under the receiver operator characteristic curve [AUC] = 0.926, any anxiety disorder (AUC = 0.807 and any mood disorder (AUC = 0.806. The concordance between the CIDI and the SCID for psychotic and eating disorders is moderate. However, for individual mental disorders, the CIDI-SCID concordance for bipolar disorders (AUC = 0.55 and anorexia nervosa (AUC = 0.50 was insufficient. Conclusions: Overall, the Chinese version of CIDI-3.0 has acceptable validity in diagnosing the substance use disorder, anxiety disorder and mood disorder among Chinese adult population. However, we should be cautious when using it for bipolar disorders and anorexia nervosa.

  4. 78 FR 39327 - Bio Diagnostic International; Denial of Application

    Science.gov (United States)

    2013-07-01

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration [Docket No. 11-63] Bio Diagnostic... Control, Drug Enforcement Administration, issued an Order to Show Cause to Bio Diagnostic International... application of Bio Diagnostic International, Inc., for a DEA Certificate of Registration as a distributor of...

  5. Analysis of mental disorders in tinnitus patients performed with Composite International Diagnostic Interview.

    Science.gov (United States)

    Zirke, N; Seydel, C; Arsoy, D; Klapp, B F; Haupt, H; Szczepek, A J; Olze, H; Goebel, G; Mazurek, B

    2013-10-01

    Known association between tinnitus and psychological distress prompted us to examine patients with chronic tinnitus by using the Composite International Diagnostic Interview (CIDI), which is a standardized and reliable method used for the diagnosis of mental disorders. One hundred patients with chronic tinnitus admitted to the Tinnitus Center, Charité-Universitätsmedizin Berlin, were included in this study. Data were collected between February 2008 and February 2009. Besides CIDI, the Tinnitus Questionnaire according to Goebel and Hiller, the Hospital Anxiety Depression Scale, and the General Anxiety Disorder-7 were used. Using CIDI, we have identified one or more mental disorders in 46 tinnitus patients. In that group, we found persistent affective disorders (37 %), anxiety disorders (32 %), and somatoform disorders (27 %). Those patients who had affective or anxiety disorders were more distressed by tinnitus and were more anxious and more depressed than tinnitus patients without mental disorders. Psychological impairment positively correlated with tinnitus distress: Patients with decompensated tinnitus had significantly more affective and anxiety disorders than patients with compensated tinnitus. In the present study, we have detected a high rate (almost half of the cases) of psychological disorders occurring in patients with chronic tinnitus. The patients diagnosed with psychological disorders were predominantly affected by affective and anxiety disorders. Psychological disorders were associated with severity of tinnitus distress. Our findings imply a need for routine comprehensive screening of mental disorders in patients with chronic tinnitus.

  6. The reliability of the Brazilian version of the Composite International Diagnostic Interview (CIDI 2.1

    Directory of Open Access Journals (Sweden)

    Quintana M.I.

    2004-01-01

    Full Text Available The objective of the present study was to determine the reliability of the Brazilian version of the Composite International Diagnostic Interview 2.1 (CIDI 2.1 in clinical psychiatry. The CIDI 2.1 was translated into Portuguese using WHO guidelines and reliability was studied using the inter-rater reliability method. The study sample consisted of 186 subjects from psychiatric hospitals and clinics, primary care centers and community services. The interviewers consisted of a group of 13 lay and three non-lay interviewers submitted to the CIDI training. The average interview time was 2 h and 30 min. General reliability ranged from kappa 0.50 to 1. For lifetime diagnoses the reliability ranged from kappa 0.77 (Bipolar Affective Disorder to 1 (Substance-Related Disorder, Alcohol-Related Disorder, Eating Disorders. Previous year reliability ranged from kappa 0.66 (Obsessive-Compulsive Disorder to 1 (Dissociative Disorders, Maniac Disorders, Eating Disorders. The poorest reliability rate was found for Mild Depressive Episode (kappa = 0.50 during the previous year. Training proved to be a fundamental factor for maintaining good reliability. Technical knowledge of the questionnaire compensated for the lack of psychiatric knowledge of the lay personnel. Inter-rater reliability was good to excellent for persons in psychiatric practice.

  7. Validity of a Farsi translation of the composite International Diagnostic Interview (CIDI to diagnose schizophrenia and bipolar disorder

    Directory of Open Access Journals (Sweden)

    H. Amini

    2006-08-01

    Full Text Available Background: The Composite International Diagnostic Interview (CIDI is a comprehensive, standardized diagnostic interview for the assessment of psychiatric disorders. There have been few studies on the validity of the CIDI. The objective of present study was to assess the validity of a Farsi translation of the complete CIDI and its psychosis/mania module in five referral clinical psychiatric settings. Methods: Two hundred and three as well as 104 consecutive admissions were interviewed using the complete and the psychosis/mania module, respectively. Within two days of the CIDI interview, two last year residents of psychiatry or psychiatrist who were blind to the CIDI diagnosis completed the Clinical diagnostic checklists (based on DSM-IV and ICD-10 criteria simultaneously and reached the consensus diagnosis. Data analysis was performed using SPSS 11 to determine the validity of CIDI. Results: The sensitivity and specificity for the diagnosis of schizophrenia was 0.12 and 0.96 using DSM-IV criteria. According to ICD-10 criteria, the results were the same with 0.19% sensitivity and 0.96% specificity. The sensitivity for the diagnosis of bipolar I disorder was low (0.21 using DSM-IV criteria and 0.17% using ICD-10 and specificity, high (0.90 compared to DSM-IV and 0.89 compared to ICD-10 criteria. The results were rather similar for the psychosis/mania module of CIDI. Conclusion: This study suggests that the Farsi translation of both the complete CIDI and the psychosis/mania module of CIDI have good specificity, but poor sensitivity for the diagnosis of schizophrenia and of bipolar I disorder.

  8. International Workshop on Diagnostics for ITER

    CERN Document Server

    Gorini, Giuseppe; Sindoni, Elio

    1996-01-01

    This book of proceedings collects the papers presented at the Workshop on Diagnostics for ITER, held at Villa Monastero, Varenna (Italy), from August 28 to September 1, 1995. The Workshop was organised by the International School of Plasma Physics "Piero Caldirola. " Established in 1971, the ISPP has organised over fifty advanced courses and workshops on topics mainly related to plasma physics. In particular, courses and workshops on plasma diagnostics (previously held in 1975, 1978, 1982, 1986, and 1991) can be considered milestones in the history of this institution. Looking back at the proceedings of the previous meetings in Varenna, one can appreciate the rapid progress in the field of plasma diagnostics over the past 20 years. The 1995 workshop was co-organised by the Istituto di Fisica del Plasma of the National Research Council (CNR). In contrast to previous Varenna meetings on diagnostics, which have covered diagnostics in present-day tokamaks and which have had a substantial tutorial component, the 1...

  9. International Conference on Plasma Diagnostics. Slides, papers and posters of Plasma Diagnostics 2010

    International Nuclear Information System (INIS)

    Hartfuss, H.J.; Bonhomme, G.; Grisolia, C.; Hirsch, M.; Klos, Z.; Mazouffre, S.; Musielok, J.; Ratynskaya, S.; Sadowski, M.; Van de Sanden, R.; Sentis, M.; Stroth, U.; Tereshin, V.; Tichy, M.; Unterberg, B.; Weisen, H.; Zoletnik, S.

    2011-01-01

    Plasma diagnostics 2010 is an International Conference on Diagnostic Methods involved in Research and Applications of Plasmas, originating on combining the 5. German-Polish Conference on Plasma Diagnostics for Fusion and Applications and the 7. French-Polish Seminar on Thermal Plasma in Space and Laboratory. The Scientific Committee of 'Plasma 2007' decided to concentrate the attention of future conferences more on the diagnostic development and diagnostic interpretation in the fields of high and low temperature plasmas and plasma applications. It is aimed at involving all European activities in the fields. The Scientific Program will cover the fields from low temperature laboratory to fusion plasmas of various configurations as well as dusty and astrophysical plasmas and industrial plasma applications

  10. Exploring the Diagnostic Utility of Facial Composites: Beliefs of Guilt Can Bias Perceived Similarity between Composite and Suspect

    Science.gov (United States)

    Charman, Steve D.; Gregory, Amy Hyman; Carlucci, Marianna

    2009-01-01

    Facial composite research has generally focused on the investigative utility of composites--using composites to find suspects. However, almost no work has examined the diagnostic utility of facial composites--the extent to which composites can be used as evidence against a suspect. For example, detectives and jurors may use the perceived…

  11. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  12. Proceedings of the 13th international symposium on laser-aided plasma diagnostics

    International Nuclear Information System (INIS)

    Kawahata, Kazuo

    2007-09-01

    The 9th international symposium on LASER-AIDED PLASMA DIAGNOSTICS was held from 18th November to 21st September, 2007 at Takayama, Japan. This symposium was organized by the National Institute for Fusion Science, Toki, Japan. The topics of the symposium include laser diagnostics and diagnostics aided by lasers for fusion plasmas, industrial process plasmas, environmental plasmas as well as for other plasma applications and processes related to plasmas. Hardware development related to laser-aided plasma diagnostics is another topic. Over 80 participants attended this international symposium. 1 Akazaki lecture, 10 general talks, 10 topical talks, 12 short oral talks and 45 posters were presented. This issue is the collection of the papers presented at the title symposium. The 41 of the presented papers are indexed individually. (J.P.N.)

  13. Influence of the choice of internal temperatures on the composition of CxHyOzNt plasmas out of thermodynamic equilibrium: Application to CH2 plasma

    International Nuclear Information System (INIS)

    Koalaga, Zacharie

    2002-01-01

    The purpose of this paper is to study the influence of the choice of internal temperatures on the composition of C x H y O z N t plasmas out of thermodynamic equilibrium. The numerical calculation is specially performed for CH 2 plasma in the pressure range 0.1-1 MPa and for the electron temperature range 5000-30 000 K. Precisely, the investigation of this plasma allows one to show that the choice of internal temperatures can have more influence on plasma composition than the choice of the form of the two-temperature Saha and Guldberg-Waage laws. Indeed, for one of the supposed hypotheses, it is observed that the two forms of the two-temperature system used here can give the same equilibrium composition by uncoupling the excitation temperature of the diatomic and the monatomic species. Great attention must then be given to the adopted hypothesis for internal temperature and not only to the form of the two temperature system used. An accurate comparison between the two models requires the measurement of plasma parameters such as the various internal temperatures and the species concentration. Therefore, we have also carried out an analysis of the potential experimental diagnostics of these plasma parameters. Such diagnostics can help to test and validate theoretical models

  14. A Piezoelectroluminescent Fiber-Optical Sensor for Diagnostics of the 3D Stress State in Composite Structures

    Science.gov (United States)

    Pan'kov, A. A.

    2018-05-01

    The mathematical model of a piezoelectroluminescent fiber-optical sensor is developed for diagnostics of the 3D stress state of composite structures. The sensor model is a coaxial sector-compound layered cylinder consisting of a central optical fiber with electroluminescent and piezoelectric layers and an external uniform elastic buffer layer. The electroluminescent and piezoelectric layers are separated by radial-longitudinal boundaries, common for both layers, into geometrically equal six "measuring elements" — cylindrical two-layered sectors. The directions of 3D polarization of the piezoelectric phases and the frequencies of luminous efficacy of the electroluminescent phases are different in each sector. In the sensor, a thin translucent "internal" controlling electrode is located between the optical fiber and the electroluminescent layer, and the piezoelectric layer is coated by a thin "external" controlling electrode. The results of numerical modeling of the nonuniform coupled electroelastic fields of the piezoelectroluminescent fiber-optical sensor in the loaded "representative volume" of a composite, taking into account the action of the controlling voltage on the internal and external electrodes, of a numerical calculation of "informative and controlling coefficients" of the sensor, and of testing of an arbitrary 3D stress of state of a unidirectional glass-fiber plastic by the finite-element method are presented.

  15. The Absolute Deviation Rank Diagnostic Approach to Gear Tooth Composite Fault

    Directory of Open Access Journals (Sweden)

    Guangbin Wang

    2017-01-01

    Full Text Available Aiming at nonlinear and nonstationary characteristics of the different degree with single fault gear tooth broken, pitting, and composite fault gear tooth broken-pitting, a method for the diagnosis of absolute deviation of gear faults is presented. The method uses ADAMS, respectively, set-up dynamics model of single fault gear tooth broken, pitting, and composite fault gear tooth broken-pitting, to obtain the result of different degree of broken teeth, pitting the single fault and compound faults in the meshing frequency, and the amplitude frequency doubling through simulating analysis. Through the comparison with the normal state to obtain the sensitive characteristic of the fault, the absolute value deviation diagnostic approach is used to identify the fault and validate it through experiments. The results show that absolute deviation rank diagnostic approach can realize the recognition of gear single faults and compound faults with different degrees and provide quick reference to determine the degree of gear fault.

  16. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group (WG 10) to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray installations. Since then, the working group has produced a report on General Aspects of Quality Assurance in Diagnostic X-ray Departments and four draft standards on specific topics, while seven more documents are in advanced drafting stage. Several others are presently under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform the tests and interpret their results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standard produced so far, with emphasis on the physical parameters of diagnostic X-ray installations and their proposed criteria for satisfactory performance. (author)

  17. [Pharmacovigilance center --internal medicine interactions: A useful diagnostic tool].

    Science.gov (United States)

    Rochoy, M; Gautier, S; Bordet, R; Caron, J; Launay, D; Hachulla, E; Hatron, P-Y; Lambert, M

    2015-08-01

    Patients hospitalized in internal medicine often have unexplained clinical symptoms for which a drug origin can be considered. The prevalence of patients hospitalized for iatrogenic is estimated between 4-22%. We wanted to evaluate the diagnostic value of the regional center of pharmacovigilance to identify or confirm an iatrogenic disease in the department of internal medicine of Lille and characterize factors associated with drug-related side effect. This is a single-center prospective diagnostic study. We included all subsequent requests from the department of internal medicine with the Nord-Pas-de-Calais regional pharmacovigilance center between 2010 and 2012. The opinion of the regional pharmacovigilance centre was held on the record of the adverse drug reaction in the national pharmacovigilance database and analyzed according to the conclusion of iatrogenic used by clinicians in internal medicine (reference diagnosis) with a follow-up to June 2013. The variables relating to the patient, medication and adverse events were analyzed by binary logistic regression. We analyzed 160 contacts: 118 concordant cases, 38 false-positives (drug-related side effect retained by the regional pharmacovigilance center only), 4 false negatives. Registration in the national pharmacovigilance database had a sensitivity of 96% (95% CI [0.92 to 0.99]), a specificity of 46% (95% CI [0.38 to 0.53]), a value positive predictive of 69% (95% CI [0.62 to 0.76]), a negative predictive value of 89% (95% CI [0.84 to 0.94]) and a negative likelihood ratio of 0.1. False-positive had chronological and semiological accountabilities questionable (adjusted RR=2.1, 95% CI [1.2 to 2.8]). In our study, the regional pharmacovigilance center confirms the clinician's suspicion of drug-related side effects and helps to exclude drug-induced with a high negative predictive value. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  18. An overview of the International Electrotechnical Commission's activities on quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Julius, H.W.; Ammers, H. van; Henshaw, E.T.

    1989-01-01

    In 1981, the International Electrotechnical Commission Sub-committee 62B set up a Working Group to deal with quality assurance in diagnostic X-ray departments and, more specifically, to develop international standards describing procedures to test the constancy of parameters of diagnostic X-ray Departments, four draft standards on specific topics, seven more documents are in advanced stage, and several others under consideration. According to the approach adopted by the Working Group, these documents are meant to assist in establishing quality assurance programmes in hospitals and provide guidance on how to perform tests and interpret results. This paper reveals the general philosophy behind the activities of the Working Group as well as some details of the standards produced so far, with emphasis on physical parameters of diagnostic X-ray installations and proposed criteria for satisfactory performance. (author)

  19. A new asteroseismic diagnostic for internal rotation in γ Doradus stars

    DEFF Research Database (Denmark)

    Ouazzani, Rhita-Maria; Salmon, S. J. A. J.; Antoci, V.

    2017-01-01

    to rotation. In this paper, we define a new seismic diagnostic for rotation in γ Doradus stars which are too rapidly rotating to present rotational splittings. Based on the non-uniformity of their period spacings, we define the observable Σ as the slope of the period spacing when plotted as a function......With four years of nearly continuous photometry from Kepler, we are finally in a good position to apply asteroseismology to γ Doradus stars. In particular, several analyses have demonstrated the possibility to detect non-uniform period spacings, which have been predicted to be directly related...... of period. We provide a one-to-one relation between this observable Σ and the internal rotation, which applies widely in the instability strip of γ Doradus stars. We apply the diagnostic to a handful of stars observed by Kepler. Thanks to g modes in γ Doradus stars, we are now able to determine the internal...

  20. CLASSIFICATION OF TEMPOROMANDIBULAR-JOINT OSTEOARTHROSIS AND INTERNAL DERANGEMENT .2. SPECIFIC DIAGNOSTIC-CRITERIA

    NARCIS (Netherlands)

    STEGENGA, B; DEBONT, LGM; BOERING, G

    Separate entities of temporomandibular joint osteoarthrosis and internal derangement are operationally defined. Criteria are based on an analysis of the diagnostic significance of symptoms and signs, principles of synovial joint pathology in general, and on therapeutic considerations. The primary

  1. The European Union CREATE project: a model for international standardization of allergy diagnostics and vaccines

    NARCIS (Netherlands)

    Chapman, Martin D.; Ferreira, Fatima; Villalba, Mayte; Cromwell, Oliver; Bryan, Donna; Becker, Wolf-Meinhard; Fernández-Rivas, Montserrat; Durham, Stephen; Vieths, Stefan; van Ree, Ronald; Aalbers, M.; Notten, S.; Ooievaar-de Heer, P.; Ferreira, F.; Gademaier, G.; Wallner, M.; Villalba, M.; Rodriguez, R.; Becker, W.-M.; Eberhardt, F.; Lepp, U.; Raulf-Heimsoth, M.; Valenta, R.; Focke, M.; Bryan, D.; Dolman, C.; Das, R. G.; Vieths, S.; Fötisch, K.; Di Felice, G.; Pini, C.; Cromwell, O.; Fiebig, H.; Weber, B.; van Schijndel, H.; Dorpema, J. W.; Marco, F. M.; Monsalve, R.; Barber, D.; Caldas, E. Fernandez; Moingeon, P.; Didierlaurent, A.; André, C.; Kroon, A.; Neubauer, A.; Chapman, M.; Vailes, L.; Tsay, A.; Durham, S.; Custovic, A.; Simpson, B.; Knulst, A.; Rivas, M. Fernández; Mancebo, E. Gonzalez; Bahima, A. Cistero; Moncin, M. M. San Miguel; Mari, A.; Kinaciyan, T.; Quiralte, J.; Pauli, G.; de Blay, F.; Purohit, A.; Rak, S.

    2008-01-01

    Allergen measurements are used extensively in the formulation of allergy diagnostics and vaccines, yet no purified international allergen standards are available for calibration purposes. The aims of the European Union CREATE project were to develop international standards with verifiable allergen

  2. Young modulus and internal friction of a fiber-reinforced composite

    International Nuclear Information System (INIS)

    Ledbetter, H.M.; Lei, M.; Austin, M.W.

    1986-01-01

    By a kilohertz-frequency resonance method we determined the Young modulus and internal friction of a uniaxially fiber-reinforced composite. The composite comprised glass fibers in an epoxy-resin matrix. We studied three fiber contents: 0, 41, and 49 vol %. The Young modulus fit a linear rule of mixture. The internal friction fit a classical free-damped-oscillator model where one assumes a linear rule of mixture for three quantities: mass, force constant, and mechanical-resistance constant

  3. International consensus diagnostic criteria for neuromyelitis optica spectrum disorders

    Science.gov (United States)

    Banwell, Brenda; Bennett, Jeffrey L.; Cabre, Philippe; Carroll, William; Chitnis, Tanuja; de Seze, Jérôme; Fujihara, Kazuo; Greenberg, Benjamin; Jacob, Anu; Jarius, Sven; Lana-Peixoto, Marco; Levy, Michael; Simon, Jack H.; Tenembaum, Silvia; Traboulsee, Anthony L.; Waters, Patrick; Wellik, Kay E.

    2015-01-01

    Neuromyelitis optica (NMO) is an inflammatory CNS syndrome distinct from multiple sclerosis (MS) that is associated with serum aquaporin-4 immunoglobulin G antibodies (AQP4-IgG). Prior NMO diagnostic criteria required optic nerve and spinal cord involvement but more restricted or more extensive CNS involvement may occur. The International Panel for NMO Diagnosis (IPND) was convened to develop revised diagnostic criteria using systematic literature reviews and electronic surveys to facilitate consensus. The new nomenclature defines the unifying term NMO spectrum disorders (NMOSD), which is stratified further by serologic testing (NMOSD with or without AQP4-IgG). The core clinical characteristics required for patients with NMOSD with AQP4-IgG include clinical syndromes or MRI findings related to optic nerve, spinal cord, area postrema, other brainstem, diencephalic, or cerebral presentations. More stringent clinical criteria, with additional neuroimaging findings, are required for diagnosis of NMOSD without AQP4-IgG or when serologic testing is unavailable. The IPND also proposed validation strategies and achieved consensus on pediatric NMOSD diagnosis and the concepts of monophasic NMOSD and opticospinal MS. PMID:26092914

  4. International veterinary epilepsy task force consensus proposal : diagnostic approach to epilepsy in dogs

    NARCIS (Netherlands)

    De Risio, Luisa; Bhatti, Sofie; Muñana, Karen; Penderis, Jacques; Stein, Veronika; Tipold, Andrea; Berendt, Mette; Farqhuar, Robyn; Fischer, Andrea; Long, Sam; Mandigers, Paul J J; Matiasek, Kaspar; Packer, Rowena M A; Pakozdy, Akos; Patterson, Ned; Platt, Simon; Podell, Michael; Potschka, Heidrun; Batlle, Martí Pumarola; Rusbridge, Clare; Volk, Holger A

    2015-01-01

    This article outlines the consensus proposal on diagnosis of epilepsy in dogs by the International Veterinary Epilepsy Task Force. The aim of this consensus proposal is to improve consistency in the diagnosis of epilepsy in the clinical and research settings. The diagnostic approach to the patient

  5. How to Move Beyond the Diagnostic and Statistical Manual of Mental Disorders/International Classification of Diseases.

    Science.gov (United States)

    Schildkrout, Barbara

    2016-10-01

    A new nosology for mental disorders is needed as a basis for effective scientific inquiry. Diagnostic and Statistical Manual of Mental Disorders and International Classification of Diseases diagnoses are not natural, biological categories, and these diagnostic systems do not address mental phenomena that exist on a spectrum. Advances in neuroscience offer the hope of breakthroughs for diagnosing and treating major mental illness in the future. At present, a neuroscience-based understanding of brain/behavior relationships can reshape clinical thinking. Neuroscience literacy allows psychiatrists to formulate biologically informed psychological theories, to follow neuroscientific literature pertinent to psychiatry, and to embark on a path toward neurologically informed clinical thinking that can help move the field away from Diagnostic and Statistical Manual of Mental Disorders and International Classification of Diseases conceptualizations. Psychiatrists are urged to work toward attaining neuroscience literacy to prepare for and contribute to the development of a new nosology.

  6. Marginal and internal fit of nano-composite CAD/CAM restorations

    Directory of Open Access Journals (Sweden)

    So-Hyun Park

    2016-02-01

    Full Text Available Objectives The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods A full veneer crown and an mesio-occluso-distal (MOD inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU and experimental nano-composite CAD/CAM blocks (EB under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000. In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001. Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000. Conclusions The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

  7. Cultural adaptation of the Latin American version of the World Health Organization Composite International Diagnostic Interview (WHO-CIDI) (v 3.0) for use in Spain.

    Science.gov (United States)

    Navarro-Mateu, Fernando; Morán-Sánchez, Inés; Alonso, Jordi; Tormo, Ma José; Pujalte, Ma Luisa; Garriga, Ascensión; Aguilar-Gaxiola, Sergio; Navarro, Carmen

    2013-01-01

    To develop a Spanish version of the WHO-Composite International Diagnostic Interview (WHO-CIDI) applicable to Spain, through cultural adaptation of its most recent Latin American (LA v 20.0) version. A 1-week training course on the WHO-CIDI was provided by certified trainers. An expert panel reviewed the LA version, identified words or expressions that needed to be adapted to the cultural or linguistic norms for Spain, and proposed alternative expressions that were agreed on through consensus. The entire process was supervised and approved by a member of the WHO-CIDI Editorial Committee. The changes were incorporated into a Computer Assisted Personal Interview (CAPI) format and the feasibility and administration time were pilot tested in a convenience sample of 32 volunteers. A total of 372 questions were slightly modified (almost 7% of approximately 5000 questions in the survey) and incorporated into the CAPI version of the WHO-CIDI. Most of the changes were minor - but important - linguistic adaptations, and others were related to specific Spanish institutions and currency. In the pilot study, the instrument's mean completion administration time was 2h and 10min, with an interquartile range from 1.5 to nearly 3h. All the changes made were tested and officially approved. The Latin American version of the WHO-CIDI was successfully adapted and pilot-tested in its computerized format and is now ready for use in Spain. Copyright © 2012 SESPAS. Published by Elsevier Espana. All rights reserved.

  8. Application of neural networks and neutron noise for diagnostics of reactor internals vibration

    International Nuclear Information System (INIS)

    Garis, N.S.; Pazsit, I.; Gloeckler, O.

    1995-01-01

    It has long been known that vibration of reactor internals, in particular excessive vibrations of control rods, can be detected via the neutron noise they induce. Noise measurements are actually suitable to determine important diagnostic parameters such as the location of the vibrating rod and the vibration amplitude. An algorithm was earlier elaborated for this purpose, which is based on inversion of the expression describing the neutron noise as a function of vibration parameters. This inversion procedure is nevertheless complicated and not always unique. It was investigated whether a properly trained neural network can perform the inversion more effectively. It was found that artificial neural networks can be trained effectively to perform vibration diagnostics from neutron noise data fast, effectively and reliably. The present paper gives a description of the development and use of the neural networks for purposes of vibration diagnostics

  9. 6th International Workshop on Compositional Data Analysis

    CERN Document Server

    Thió-Henestrosa, Santiago

    2016-01-01

    The authoritative contributions gathered in this volume reflect the state of the art in compositional data analysis (CoDa). The respective chapters cover all aspects of CoDa, ranging from mathematical theory, statistical methods and techniques to its broad range of applications in geochemistry, the life sciences and other disciplines. The selected and peer-reviewed papers were originally presented at the 6th International Workshop on Compositional Data Analysis, CoDaWork 2015, held in L’Escala (Girona), Spain. Compositional data is defined as vectors of positive components and constant sum, and, more generally, all those vectors representing parts of a whole which only carry relative information. Examples of compositional data can be found in many different fields such as geology, chemistry, economics, medicine, ecology and sociology. As most of the classical statistical techniques are incoherent on compositions, in the 1980s John Aitchison proposed the log-ratio approach to CoDa. This became the foundation...

  10. Diagnostic imaging in internal medicine

    International Nuclear Information System (INIS)

    Eisenberg, R.L.

    1985-01-01

    This book examines medical diagnostic techniques. Topics considered include biological considerations in the approach to clinical medicines; infectious diseases; disorders of the heart; disorders of the vascular system; disorders of the respiratory system; diseases of the kidneys and urinary tract; disorders of the alimentary tract; disorders of the hepatobiliary system and pancreas; disorders of the hematopoietic system; disorders of bone and bone mineralization; disorders of the joints, connective tissues, and striated muscles; disorders of the nervous system; miscellaneous disorders; and procedures in diagnostic imaging

  11. Using laser absorption spectroscopy to monitor composition and physical properties of metal vapors

    International Nuclear Information System (INIS)

    Berzins, L.V.

    1993-01-01

    The Atomic Vapor Laser Isotope Separation (AVLIS) program has been using laser absorption spectroscopy to monitor vapor densities for over 15 years. Laser absorption spectroscopy has proven itself to be an accurate and reliable method to monitor both density and composition. During this time the diagnostic has moved from a research tool toward a robust component of a process control system. The hardware used for this diagnostic is discussed elsewhere at this symposium. This paper describes how the laser absorption spectroscopy diagnostic is used as a component of a process control system as well as supplying detailed measurements on vapor densities, composition, flow velocity, internal and kinetic temperatures, and constituent distributions. Examples will be drawn from the uranium AVLIS program. In addition potential applications such as composition control in the production of metal matrix composites or aircraft alloys will be discussed

  12. Elastic constants and internal friction of fiber-reinforced composites

    International Nuclear Information System (INIS)

    Ledbetter, H.M.

    1982-01-01

    We review recent experimental studies at NBS on the anisotropic elastic constants and internal friction of fiber-reinforced composites. Materials that were studied include: boron-aluminum, boron-epoxy, graphite-epoxy, glass-epoxy, and aramid-epoxy. In all cases, elastic-constant direction dependence could be described by relationships developed for single crystals of homogeneous materials. Elastic stiffness and internal friction were found to vary inversely

  13. Use of a perfume composition as a fuel for internal combustion engines

    NARCIS (Netherlands)

    2013-01-01

    The present invention relates to fuel compositions containing perfume fractions, that is to say compositions of fragrance materials, and to the use of such perfume fractions containing fuel compositions to provide a fuel for internal combustion engines and burners. According to the present fuel

  14. Stability analysis of internally damped rotating composite shafts using a finite element formulation

    Science.gov (United States)

    Ben Arab, Safa; Rodrigues, José Dias; Bouaziz, Slim; Haddar, Mohamed

    2018-04-01

    This paper deals with the stability analysis of internally damped rotating composite shafts. An Euler-Bernoulli shaft finite element formulation based on Equivalent Single Layer Theory (ESLT), including the hysteretic internal damping of composite material and transverse shear effects, is introduced and then used to evaluate the influence of various parameters: stacking sequences, fiber orientations and bearing properties on natural frequencies, critical speeds, and instability thresholds. The obtained results are compared with those available in the literature using different theories. The agreement in the obtained results show that the developed Euler-Bernoulli finite element based on ESLT including hysteretic internal damping and shear transverse effects can be effectively used for the stability analysis of internally damped rotating composite shafts. Furthermore, the results revealed that rotor stability is sensitive to the laminate parameters and to the properties of the bearings.

  15. A study on the fault diagnostic techniques for reactor internal structures using neutron noise analysis

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Jeong, Seong Ho; Park, Jin Ho; Park, Jin Suk

    1994-08-01

    The unfavorable phenomena, such as flow induced vibration and aging process in reactor internals, cause degradation of structural integrity and may result in loosing some mechanical binding components which might impact other equipments and components or cause flow blockage. Since these malfunctions and potential failures change reactor noise signal, it is necessary to analyze reactor noise signal for early fault diagnosis in the point of few of safety and plant economics. The objectives of this study are to establish fault diagnostic and TS(thermal shield), and to develop a data acquisition and signal processing software system. In the first year of this study, an analysis technique for the reactor internal vibration using the reactor noise was proposed. With the technique proposed and the reactor noise signals (ex-core neutron and acceleration), the dynamic characteristics of Ulchin-1 reactor internals were obtained, and compared with those of Tricastin-1 which is the prototype of Ulchin-1. In the second year, a PC-based expert system for reactor internals fault diagnosis is developed, which included data acquisition, signal processing, feature extraction function, and represented diagnostic knowledge by the IF-THEN rule. To know the effect of the faults, the reactor internals of Ulchin-1 is modeled using FEM and simulated with an artificial defect given in the hold-down spring. Trend in the dynamic characteristics of reactor internals is also observed during one fuel cycle to know the effect of boron concentration. 100 figs, 7 tabs, 18 refs. (Author)

  16. Student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures

    International Nuclear Information System (INIS)

    Zhou, G. Z.; Wong, D. D.; Nguyen, L. K.; Mendelson, R. M.

    2010-01-01

    Full text: This study aims to evaluate medical student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures and to suggest how education could be improved. Fourth to sixth year medical students enrolled at a Western Australian university and interns from three teaching hospitals in Perth were recruited. Participants were asked to complete a questionnaire consisting of 26 questions on their background, knowledge of ionising radiation doses and learning preferences for future teaching on this subject. A total of 331 completed questionnaires were received (95.9%). Of the 17 questions assessing knowledge of ionising radiation, a mean score of 6.0 was obtained by respondents (95% CI 5.8-6.2). Up to 54.8% of respondents underestimated the radiation dose from commonly requested radiological procedures. Respondents (11.3 and 25.5%) incorrectly believed that ultrasound and MRI emit ionising radiation, respectively. Of the four subgroups of respondents, the intern doctor subgroup performed significantly better (mean score 6.9, P< 0.0001, 95% CI 6.5-7.3) than each of the three medical student subgroups. When asked for the preferred method of teaching for future radiation awareness, a combination of lectures, tutorials and workshops was preferred. This study has clearly shown that awareness of ionising radiation from diagnostic imaging is lacking among senior medical students and interns. The results highlight the need for improved education to minimise unnecessary exposure of patients and the community to radiation. Further studies are required to determine the most effective form of education.

  17. Improved Internal Reference Oxygen Sensors with Composite Ceramic Electrodes

    DEFF Research Database (Denmark)

    Hu, Qiang; Jacobsen, Torben; Hansen, Karin Vels

    2012-01-01

    Potentiometric oxygen sensors with an internal reference electrode, which uses the equilibrium pO2 of the binary mixture of Ni/NiO as the reference, are demonstrated. The cells employ Pt or composite ceramics as the sensing electrode. The cells are fabricated by a flexible and potentially low cost...... and performance are highly reproducible. The composite ceramics, based on strontium doped manganite and yttria doped zirconia, are proven superior over Pt to serve as the electrode material....

  18. International Reserves and the Composition of Equity Capital Inflows

    OpenAIRE

    Xingwang Qian; Andreas Steiner

    2012-01-01

    We study the effect of central banks' international reserve hoardings on the composition of equity capital inflows, namely the ratio of portfolio equity investment (PEI) to foreign direct investment (FDI). Foreign investors' decisions regarding the location and the type of equity capital investment might be influenced by a country's level of international reserves. In a simple theoretical model, we show that higher reserves, thanks to their ability to lower exchange rate risk, reduce the risk...

  19. Particle compositions with a pre-selected cell internalization mode

    Science.gov (United States)

    Decuzzi, Paolo (Inventor); Ferrari, Mauro (Inventor)

    2012-01-01

    A method of formulating a particle composition having a pre-selected cell internalization mode involves selecting a target cell having surface receptors and obtaining particles that have i) surface moieties, that have an affinity for or are capable of binding to the surface receptors of the cell and ii) a preselected shape, where a surface distribution of the surface moieties on the particles and the shape of the particles are effective for the pre-selected cell internalization mode.

  20. Antenna design for fast ion collective Thomson scattering diagnostic for the international thermonuclear experimental reactor

    DEFF Research Database (Denmark)

    Leipold, Frank; Furtula, Vedran; Salewski, Mirko

    2009-01-01

    Fast ion physics will play an important role for the international thermonuclear experimental reactor (ITER), where confined alpha particles will affect and be affected by plasma dynamics and thereby have impacts on the overall confinement. A fast ion collective Thomson scattering (CTS) diagnostic...

  1. International society of sports nutrition position stand: diets and body composition

    OpenAIRE

    Aragon, Alan A.; Schoenfeld, Brad J.; Wildman, Robert; Kleiner, Susan; VanDusseldorp, Trisha; Taylor, Lem; Earnest, Conrad P.; Arciero, Paul J.; Wilborn, Colin; Kalman, Douglas S.; Stout, Jeffrey R.; Willoughby, Darryn S.; Campbell, Bill; Arent, Shawn M.; Bannock, Laurent

    2017-01-01

    Position Statement: The International Society of Sports Nutrition (ISSN) bases the following position stand on a critical analysis of the literature regarding the effects of diet types (macronutrient composition; eating styles) and their influence on body composition. The ISSN has concluded the following. 1) There is a multitude of diet types and eating styles, whereby numerous subtypes fall under each major dietary archetype. 2) All body composition assessment methods have strengths and limi...

  2. The Effects of Changing Membrane Compositions and Internal Electrolytes on the Respon of Potassium Ion Sensor

    OpenAIRE

    Ulianas, Alizar; Heng, Lee Yook

    2015-01-01

    A study on the changing of membrane compositions and internal solution towards the response potassium ion sensor was carried out. Potassium ion sensor based on photocured cross linking poly(n-butyl acrylate) membranes with varying composition of valinomycin (val), sodium tetrakis [3.5-bis(trifluoro-methyl) phenyl] borat (NaTFPB), types ion of internal solution were investigated. Effects of varying composition of val, NaTFPB, types and concentration of internal solution were observed on potass...

  3. Qualitative Event-Based Diagnosis: Case Study on the Second International Diagnostic Competition

    Science.gov (United States)

    Daigle, Matthew; Roychoudhury, Indranil

    2010-01-01

    We describe a diagnosis algorithm entered into the Second International Diagnostic Competition. We focus on the first diagnostic problem of the industrial track of the competition in which a diagnosis algorithm must detect, isolate, and identify faults in an electrical power distribution testbed and provide corresponding recovery recommendations. The diagnosis algorithm embodies a model-based approach, centered around qualitative event-based fault isolation. Faults produce deviations in measured values from model-predicted values. The sequence of these deviations is matched to those predicted by the model in order to isolate faults. We augment this approach with model-based fault identification, which determines fault parameters and helps to further isolate faults. We describe the diagnosis approach, provide diagnosis results from running the algorithm on provided example scenarios, and discuss the issues faced, and lessons learned, from implementing the approach

  4. Insights into cerumen and application in diagnostics: past, present and future prospective.

    Science.gov (United States)

    Shokry, Engy; Filho, Nelson Roberto Antoniosi

    2017-10-15

    Cerumen or earwax is an emerging bio-fluid in clinical diagnosis that has been very little exploited during the past decades in spite of its high diagnostic potential. It is highly abundant in diagnostic biomarkers such as genetic material, lipids, proteins, chemical elements, internal and external metabolites ( e.g. hormones, volatile organic compounds, amino acids, xenobiotics etc. ) reaching earwax from the blood circulation. Thus, it is able to reflect not only physiology, pathophysiology of the human body but can also detect recent and long term exposure to environmental pollutants, without the need of invasive blood tests and in the same time overcoming many disadvantages faced by using other diagnostic biological fluids. This review discusses the biology, functions, chemistry of earwax, past and current approaches for the study of its chemical composition, emphasizing how a detected variation in its composition can offer information of high clinical value, which can be useful in diagnosis of many diseases such as metabolic disorders and tumours as well as in forensic applications. It also presents details about techniques of sample collection, storage, and analysis. Moreover, it highlights concerns about the use of earwax for diagnostic purposes, which should be addressed to make earwax diagnostics a reality in the future.

  5. The Evolution and Internal Structure of Jupiter and Saturn with Compositional Gradients

    NARCIS (Netherlands)

    Vazan, A.; Helled, R.; Podolak, M.; Kovetz, A.

    2016-01-01

    The internal structure of gas giant planets may be more complex than the commonly assumed core-envelope structure with an adiabatic temperature profile. Different primordial internal structures as well as various physical processes can lead to non-homogenous compositional distributions. A

  6. Propagation of internal stresses in composite materials during heating and cooling according to thermal cycles of welding

    International Nuclear Information System (INIS)

    Gukasyan, L.E.; Belov, V.V.

    1977-01-01

    Investigations of free thermal expansion of a composite material, of fibre and matrix during welding thermal cycle make it possible to estimate mean internal strain and stress in the composite components, as well as the residual internal stress and strain present in the composite material after manufacturing. The samples investigated consisted of nickel-chromium EhI445 alloy, reinforced by tungsten-rhenium alloy fibres. As the composite material was cooled and heated in course of welding, the stress and strain changed their sign twice, the first time upon heating, the second time upon cooling. After complete cooling of the composite material residual stresses in the fibre stay at the proportionality level, while those in the matrix are lower. Experimental evidence of internal stress and strain appearing in the composite material during heating are fairly consistent with calculations in the elastic region, if account is taken of the temperature of internal residual stress relaxation upon heating

  7. Method for remote diagnostics of the internal structure of layered media

    International Nuclear Information System (INIS)

    Lychagov, V V; Kal'yanov, A L; Ryabukho, V P; Lyakin, D V

    2008-01-01

    The method of autocorrelation low coherence interferometry is proposed for diagnostics of inhomogeneities and the internal structure of layered technical and biological samples. In this method the low coherence optical field reflected from the layered sample is analysed by using a Michelson interferometer. Because the object is outside the interferometer, the distance between the interferometer and the object under study is not limited and thus the object can move during the measurements. Theoretical substantiation of the autocorrelation method for media with discrete and continuous optical structure modifications is presented. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

  8. Study of the barite mortar composition and its influence on determination of primary transmission curves applied to diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Firmino, Sandro F.; Souza, Wedla P. de; Hoff, Gabriela, E-mail: sandro.frmino@pucrs.b, E-mail: wedla.souza@acad.pucrs.b, E-mail: ghoff@pucrs.b [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Fac. de Fisica. Grupo de Experimentacao e Simulacao Computacional em Fisica Medica (GESiC); Vilhena, Marco T., E-mail: vilhena@pq.cnpq.b [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica

    2009-07-01

    The transmission of photons is an important parameter used to calculate the shielding material thickness. The method of computational simulation purposed, in this work, was applied to generate transmission curves for different energies for monoenergetic beams, on diagnostic radiology energy range, for values between 60 and 150 keV, in steps of 10 keV; and polienergetics spectra for accelerating tube tensions of 140 kVp and 150 kVp. The polienergetic spectra were selected from the Catalogue of Diagnostic X-Ray Spectra and Other Data [1] and changed using deterministic methods to add Aluminum filtration of 3.0 mm. The main objective of this work was to verify the sensitivity of photons spectra to differences observed on barite mortar composition. The computational universe generated simulates photon spectra irradiating directly a shielding wall. The different barite mortar compositions were defined base on a unique sample analysed using the energy dispersion spectroscopy (EDS) measurements in a Philips XL 30 Scanning Electron Microscope (SEM). The compositions were realized on four different areas of one sample: one on opened field of view and the three others uses focused field of view. It was possible verify differences on transmission curves for the different studied energies and different compositions of barite mortar. We suggest future works to study realistic spectra for different barite mortar compositions commercialized in Brazil. (author)

  9. Development of transient internal probe (TIP) magnetic field diagnostic

    International Nuclear Information System (INIS)

    Galambos, J.P.; Bohnet, M.A.; Jarboe, T.R.; Mattick, A.T.

    1994-01-01

    The Transient Internal Probe (TIP) is designed to permit measurement of internal magnetic fields, in hot, high density plasmas. The concept consists of accelerating a probe to high velocities (2.2 Km/s) in order to minimize probe exposure time to plasma. Faraday rotation within the probe is used to measure the local magnetic field. An Argon laser illuminates the probe consisting of a Faraday-rotator material with a retro-reflector that returns the incident light to the detection system. Performance results of the light gas gun and optical detection system will be shown. To date, the gas gun has been extensively tested consistently achieving velocities between 2 and 3 km/s. The probe and detection scheme have been tested by dropping the probe through a static magnetic field. Magnetic field resolution of 20 gauss and spatial resolution of 5 mm has been achieved. System frequency response is 10Mhz. Work is currently being conducted to integrate the diagnostic system with laboratory plasma experiments. Specifically a gas interfaced system has been developed to prevent helium muzzle gas from entering the plasma chamber with the probe. Additionally the probe must be separated from the sabot which protects the probe during acceleration in the gas gun. Data will be presented showing the results of various separation techniques

  10. Transforming Internal Activities of Business Process Models to Services Compositions

    NARCIS (Netherlands)

    Dirgahayu, Teduh; Quartel, Dick; van Sinderen, Marten J.; Mostefaoui, S.K.; Maamar, Z.; Ferreira Pires, L.; Hammoudi, S.; Rinderle-Ma, S.; Sadiq, S.; Schulz, K.

    As a service composition language, BPEL imposes as constraint that a business process model should consist only of activities for interacting with other business processes. BPEL provides limited support for implementing internal activities, i.e. activities that are performed by a single business

  11. Sample Stability and Protein Composition of Saliva: Implications for Its Use as a Diagnostic Fluid

    Directory of Open Access Journals (Sweden)

    Han Roelofsen

    2008-01-01

    Full Text Available Saliva is an easy accessible plasma ultra-filtrate. Therefore, saliva can be an attractive alternative to blood for measurement of diagnostic protein markers. Our aim was to determine stability and protein composition of saliva. Protein stability at room temperature was examined by incubating fresh whole saliva with and without inhibitors of proteases and bacterial metabolism followed by Surface Enhanced Laser Desorption/Ionization (SELDI analyses. Protein composition was determined by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE fractionation of saliva proteins followed by digestion of excised bands and identification by liquid chromatography tandem mass spectrometry (LC-MS/MS. Results show that rapid protein degradation occurs within 30 minutes after sample collection. Degradation starts already during collection. Protease inhibitors partly prevented degradation while inhibition of bacterial metabolism did not affect degradation. Three stable degradation products of 2937 Da, 3370 Da and 4132 Da were discovered which can be used as markers to monitor sample quality. Saliva proteome analyses revealed 218 proteins of which 84 can also be found in blood plasma. Based on a comparison with seven other proteomics studies on whole saliva we identified 83 new saliva proteins. We conclude that saliva is a promising diagnostic fl uid when precautions are taken towards protein breakdown.

  12. Monitoring on internal temperature of composite insulator with embedding fiber Bragg grating for early diagnosis

    Science.gov (United States)

    Chen, Wen; Tang, Ming

    2017-04-01

    The abnormal temperature rise is the precursor of the defective composite insulator in power transmission line. However no consolidated techniques or methodologies can on line monitor its internal temperature now. Thus a new method using embedding fiber Bragg grating (FBG) in fiber reinforced polymer (FRP) rod is adopted to monitor its internal temperature. To correctly demodulate the internal temperature of FRP rod from the Bragg wavelength shift of FBG, the conversion coefficient between them is deduced theoretically based on comprehensive investigation on the thermal stresses of the metal-composite joint, as well as its material and structural properties. Theoretical model shows that the conversion coefficients of FBG embedded in different positions will be different because of non-uniform thermal stress distribution, which is verified by an experiment. This work lays the theoretical foundation of monitoring the internal temperature of composite insulator with embedding FBG, which is of great importance to its health structural monitoring, especially early diagnosis.

  13. Molecular Diagnostics of the Internal Structure of Starspots and Sunspots

    Science.gov (United States)

    Afram, N.; Berdyugina, S. V.; Fluri, D. M.; Solanki, S. K.; Lagg, A.; Petit, P.; Arnaud, J.

    2006-12-01

    We have analyzed the usefulness of molecules as a diagnostic tool for studying solar and stellar magnetism with the molecular Zeeman and Paschen-Back effects. In the first part we concentrate on molecules that are observed in sunspots such as MgH and TiO. We present calculated molecular line profiles obtained by assuming magnetic fields of 2-3 kG and compare these synthetic Stokes profiles with spectro-polarimetric observations in sunspots. The good agreement between the theory and observations allows us to turn our attention in the second part to starspots to gain insight into their internal structure. We investigate the temperature range in which the selected molecules can serve as indicators for magnetic fields on highly active cool stars and compare synthetic Stokes profiles with our recent observations.

  14. Improved Internal Reference Oxygen Sensors Using Composite Oxides as Electrodes

    DEFF Research Database (Denmark)

    Hu, Qiang

    The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75S...... the application of IROSes are provided. Based on the concepts and fundamentals of the IROS, internal reference sensors that detect other gas species such as hydrogen, chlorine and bromine may be developed.......The thesis describes the research on and development of an internal reference oxygen sensor (IROS). The IROS is potentiometric and uses the equilibrium pO2of the binary mixture of Ni/NiO as the reference pO2. The sensing electrode of the IROS are made from metallic Pt or the composite of (La0.75Sr0...... from 8YSZ is evaluated quantitatively and figures that may be used to design the depletion period of an IROS due to the electronic leak of 8YSZ are provided. One dimensional numerical simulations are performed to study the variation in cell voltage during the process of gas mixing, and the asymmetric...

  15. International symposium on in vivo body composition studies: Program and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    This booklet contains the program and individual abstracts for papers presented at the International symposium on in vivo body composition studies. The presentations were divided into five sessions. Individual abstracts were indexed for the Energy Data Base. (DT)

  16. Diagnostic strategy and timing of intervention in infected necrotizing pancreatitis: an international expert survey and case vignette study

    NARCIS (Netherlands)

    van Grinsven, J. (Janneke); S. van Brunschot (Sandra); P. Fockens (Paul); J. van Grinsven (Janneke); O.J. Bakker (Olaf ); van Santvoort, H.C. (Hjalmar C.); T.L. Bollen (Thomas); M.A. Boermeester (Marja); C.H.J. van Eijck (Casper); M.G. Besselink (Marc); M.J. Bruno (Marco); C.H. Dejong (Cees); K.D. Horvath (Karen); van Eijck, C.H. (Casper H.); H. van Goor (Harry); H.G. Gooszen (Hein); Horvath, K.D. (Karen D.); K.P. van Lienden (Krijn); Abdelhafez, M.; Andersson, R.; Andren-Sandberg, A.; Ashley, S.; M.C. van Baal (Mark); Baron, T.; C. Bassi (Claudio); Bradley, E.; M.W. Buchler (M.); V.C. Cappendijk; Carter, R.; Charnley, R.; Coelho, D.; Connor, S.; Dellinger, P.; C. Dervenis (Christos); J. Devière (J.); Doctor, N.; Dudeja, V.; En-qiang, M.; Escourrou, J.; Fagenholz, P.; Farkas, G.; Forsmark, C.; Freeman, M.; P.C. Freeny (Patrick); French, J.; H. Friess; Gardner, T.; Goetzinger, P.; J.W. Haveman; S. Hofker (Sijbrand); Imrie, C.; Isaji, S.; Isenmann, R.; E. Klar (Ernst); J.S. Laméris (Johan ); M. Lerch (M.); P. Lévy (Philippe); Lillemoe, K.; Löhr, M.; J. Mayerle (Julia); Mayumi, T.; Mittal, A.; Moessner, J.; Morgan, D.; K.J. Mortele (Koenraad); Nealon, W.; J.P. Neoptolemos (John); V.B. Nieuwenhuijs (Vincent); Nordback, I.; Olah, A.; K. Oppong (K.); Padbury, R.; Papachristou, G.; Parks, R.; J.-W. Poley (Jan-Werner); Radenkovic, D.; Raraty, M.; Rau, B.; V. Rebours (Vinciane); Rische, S.; Runzi, M.; Sainani, N.; Sarr, M.; Schaapherder, S.; S. Seewald (Stefan); Seifert, H.; Shimosegawa, T.; Silverman, S.; Singh, V.; Siriwardena, A.; Steinberg, W.; Sutton, R.; Takeda, K.; R. Timmer (Robin); Vege, S.; R.P. Voermans (Rogier); J.J. De Waele (Jan J.); Wang, C. (Ch.); Warshaw, A.; J. Werner (Jens Martin); B.L. Weusten (Bas); Whitcomb, D.; Wig, J.; Windsor, J.; Zyromski, N.

    2016-01-01

    textabstractBackground The optimal diagnostic strategy and timing of intervention in infected necrotizing pancreatitis is subject to debate. We performed a survey on these topics amongst a group of international expert pancreatologists. Methods An online survey including case vignettes was sent to

  17. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  18. A composite peripheral blood gene expression measure as a potential diagnostic biomarker in bipolar disorder

    DEFF Research Database (Denmark)

    Munkholm, Klaus; Peijs, L; Vinberg, M

    2015-01-01

    as a diagnostic and state biomarker in bipolar disorder. First, messenger RNA levels of 19 candidate genes were assessed in peripheral blood mononuclear cells of 37 rapid cycling bipolar disorder patients in different affective states (depression, mania and euthymia) during a 6-12-month period and in 40 age...... subjects. In patients with bipolar disorder, upregulation of NDUFV2 was observed in a depressed state compared with a euthymic state. The composite gene expression measure for discrimination between patients and healthy control subjects on the basis of 19 genes generated an area under the receiver...

  19. Exhaust Gas Temperature Measurements in Diagnostics of Turbocharged Marine Internal Combustion Engines Part I Standard Measurements

    Directory of Open Access Journals (Sweden)

    Korczewski Zbigniew

    2015-01-01

    Full Text Available The article discusses the problem of diagnostic informativeness of exhaust gas temperature measurements in turbocharged marine internal combustion engines. Theoretical principles of the process of exhaust gas flow in turbocharger inlet channels are analysed in its dynamic and energetic aspects. Diagnostic parameters are defined which enable to formulate general evaluation of technical condition of the engine based on standard online measurements of the exhaust gas temperature. A proposal is made to extend the parametric methods of diagnosing workspaces in turbocharged marine engines by analysing time-histories of enthalpy changes of the exhaust gas flowing to the turbocompressor turbine. Such a time-history can be worked out based on dynamic measurements of the exhaust gas temperature, performed using a specially designed sheathed thermocouple.

  20. International telepathology consultation: Three years of experience between the University of Pittsburgh Medical Center and KingMed Diagnostics in China

    Directory of Open Access Journals (Sweden)

    Chengquan Zhao

    2015-01-01

    Full Text Available Background: Telepathology is increasingly being employed to support diagnostic consultation services. Prior publications have addressed technology aspects for telepathology, whereas this paper will address the clinical telepathology experience of KingMed Diagnostics, the largest independent pathology medical laboratory in China. Beginning in 2012 the University of Pittsburgh Medical Center (UPMC and KingMed Diagnostics partnered to establish an international telepathology consultation service. Materials and Methods: This is a retrospective study that summarizes the telepathology experience and diagnostic consultation results between UPMC and KingMed over a period of 3 years from January 2012 to December 2014. Results: A total of 1561 cases were submitted for telepathology consultation including 144 cases in 2012, 614 cases in 2013, and 803 in 2014. Most of the cases (61.4% submitted were referred by pathologists, 36.9% by clinicians, and 1.7% by patients in China. Hematopathology received the most cases (23.7%, followed by bone/soft tissue (21.0% and gynecologic/breast (20.2% subspecialties. Average turnaround time (TAT per case was 5.4 days, which decreased from 6.8 days in 2012 to 5.0 days in 2014. Immunostains were required for most of the cases. For some difficult cases, more than one round of immunostains was needed, which extended the TAT. Among 855 cases (54.7% where a primary diagnosis or impression was provided by the referring local hospitals in China, the final diagnoses rendered by UPMC pathologists were identical in 25.6% of cases and significantly modified (treatment plan altered in 50.8% of cases. Conclusion: These results indicate that international telepathology consultation can significantly improve patient care by facilitating access to pathology expertise. The success of this international digital consultation service was dependent on strong commitment and support from leadership, information technology expertise, and

  1. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  2. International quality assurance project in colorectal cancer-unifying diagnostic and histopathological evaluation.

    Science.gov (United States)

    Jannasch, O; Udelnow, A; Romano, G; Dziki, A; Pavalkis, D; Lippert, H; Mroczkowski, P

    2014-04-01

    Several European countries are undertaking quality control projects in colorectal cancer. These efforts have led to improvements in survival, but a comparison between different projects reveals questionable results. The aim of this study is the presentation of results from hospitals in three different European countries participating in the International Quality Assurance in Colorectal Cancer (IQACC) project. For this publication, patients with cancer of the colon or rectum treated in 2009 and 2010 and recorded in the IQACC (Germany, Poland and Italy) were analysed. The comparison included number of patients, age, preoperative diagnostics (CT of the abdomen and thorax, MRI, colonoscopy, ultrasound, tumour markers), surgical approach, metastasis, height of rectal cancer and histopathological examination of a specimen (T stage, N stage and MERCURY classification for rectum resection). For short-term outcomes, general complications, wound dehiscence, tumour-free status at discharge, anastomotic leakage and in-hospital mortality were analysed. A total of 12,691 patients (6,756 with colon cancer, 5,935 with rectal cancer) were included in the analysis. Preoperative diagnostics differed significantly between countries. For pT and pN stages, several quality differences could be demonstrated, including missing stages (colon cancer: pT 5.7-12.5 %, pN 2.5-11.0 %; rectal cancer: pT 1.1-5.6 %, pN 1.1-15.5 %). The most relevant differences for short-term outcomes in colon cancer were found in general complications (4.2-22.8 %) and tumour-free status at discharge (74.5-91.7 %). In-hospital deaths ranged between 2.5 and 4.3 % and did not show significant differences. For rectal cancer, the country with the highest percentage of tumours localised less than 4 cm from the anal verge (16.0 %) showed the lowest frequency of amputation (8.5 %). Outcome differences were found for general complications (3.2-18.8 %), anastomotic leakage (0-4.3 %) and tumour-free status at discharge (72

  3. IR thermography methods for evaluation of internal defects in light composite armours

    International Nuclear Information System (INIS)

    Swiderski, W.; Szabra, D.; Szudrowicz, M.

    2009-01-01

    Complete text of publication follows. Light composite armour is a preferred solution against military and paramilitary sources of present threats as the reducing mass of battle vehicles provides a possibility of their quick air-transport. The light armours of these vehicles should be resistant against: common and rifle bullets, grenades, anti-personal mines, IED - improvised explosive devices. The range of military applications anticipated for composite armours covers a broad spectrum of materials and designs. Materials of composite armours include graphite epoxy, glass epoxy and aramid fiber composites. The composites that have been examined can include a variety of defects, such as ballistic impacts, embedded defects, manufacturing defects, thermal damage, moisture ingress and other induced defects. Methods for testing ballistic protection of light armours are known and used. First of all they consist of checking armours resistance against the bullets where the bullet velocity is known. Moreover the V50 velocity is defined during the test. In this method the V 50 velocity of a round or standard fragment is defined (according to STANAG 2920) as the velocity at which armour is penetrated at the probability 50%. The distribution of points hit by bullets or fragments on the surface of an armour is also important. In fact, only correct distribution of these points provides a guaranty for an impartial assessment of tested designs. After hitting by a bullet, shape and size of an area of damage in composite armours depends on the type and design of armour, and type of reinforcing material is particularly important. Knowledge of damage characteristics allows to arrange hitting points to avoid overlapping of damaged areas. Nondestructive testing by using IR thermography methods is very useful in evaluation of internal defects. In the paper we present the dependence between the energy of fragments/or bullets and the dimension of internal defects. (author)

  4. Vibration Diagnostics as an effective Tool for Testing Engines of Internal Combustion

    Directory of Open Access Journals (Sweden)

    Ferenc Dömötör

    2017-10-01

    Full Text Available There are several methods of automotive diagnostics used in services to detect a large variety of faults and damages of various parts of engines of internal combustion. Undoubtedly, they are effective, but they are simply unable to find all types of mechanical faults occurring during the operation. This is the reason why authors of this paper tried to use a special tool, which has been proven for years for detecting faults of rolling element bearing in rotating machinery. During their research, the authors tried to find valuable results by measuring vibration of various parts of engines. Three items were tested, a Diesel engine and two Otto motors. A large number of measurements have been taken at various speed, at different points, in different directions, with different parameter setup, etc. However, there was one setup which has been applied to all three engines. It is the measurement setup of vibration velocity, in the frequency range of 2 Hz-300 Hz. Valuable consequences have been found regarding the clogging of the air filters and the exhaust systems. As a conclusion the authors expressed their opinion, that, apart from the traditional diagnostic methods used in services, vibration measurements can also be useful, especially for detecting faults of rolling element bearings.

  5. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: early results.

    Science.gov (United States)

    Hwang, Ho Young; Kim, Jun Sung; Oh, Se Jin; Kim, Ki-Bong

    2012-11-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft trial was designed to evaluate the saphenous vein compared with the right internal thoracic artery as a Y-composite graft anastomosed to the side of the left internal thoracic artery. In this early analysis, we compared early angiographic patency rates and clinical outcomes. From September 2008 to October 2011, 224 patients with multivessel coronary artery disease were randomized prospectively to undergo off-pump revascularization using the saphenous vein group (n = 112) or the right internal thoracic artery group (n = 112) as Y-composite grafts. Early postoperative (1.4 ± 1.1 days) angiographic patency and clinical outcomes were compared. There was 1 operative death in the right internal thoracic artery group. No statistically significant differences in postoperative morbidities, including atrial fibrillation and acute renal failure, were observed between the groups. The number of distal anastomoses using the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 2.3 ± 0.8 and 1.9 ± 0.7 in the saphenous vein and right internal thoracic artery groups, respectively (P < .001). A third conduit was used in 44 patients (saphenous vein group vs right internal thoracic artery group, 4/109 vs 40/110; P < .001) to extend the side-arm Y-composite graft for complete revascularization. Early angiography demonstrated an overall patency rate of 99.4% (771 of 776 distal anastomoses). Patency rates of the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 98.8% (245 of 248) and 99.5% (207 of 208) in the saphenous vein and right internal thoracic artery groups, respectively (P = .629). A third conduit was needed to extend the right internal thoracic artery composite graft and reach the target vessels in 36.4% (40/110) of the patients. The saphenous vein composite graft was comparable with the right internal thoracic artery composite graft

  6. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)

    Energy Technology Data Exchange (ETDEWEB)

    Pablant, N. A. [University of California-San Diego, La Jolla, California 92093 (United States); Burrell, K. H.; Groebner, R. J.; Kaplan, D. H. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Holcomb, C. T. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2010-10-15

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D{sub {alpha}} emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B{sub {theta}}/B{sub T} and |B| over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0x10{sup 19} m{sup -3}, and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  7. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited).

    Science.gov (United States)

    Pablant, N A; Burrell, K H; Groebner, R J; Holcomb, C T; Kaplan, D H

    2010-10-01

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D(α) emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B(θ)/B(T) and ∣B∣ over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0×10(19) m(-3), and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  8. Diagnostics of Polymer Composite Materials and Analysis of Their Production Technology by Using the Method of Acoustic Emission

    Science.gov (United States)

    Bashkov, O. V.; Protsenko, A. E.; Bryanskii, A. A.; Romashko, R. V.

    2017-09-01

    The strength properties of glass-fiber-reinforced plastics produced by vacuum and vacuum autoclave molding techniques are studied. Based on acoustic emission data, a method of diagnostic and prediction of the bearing capacity of polymer composite materials by using data from three-point bending tests is developed. The method is based on evaluating changes in the exponent of a power function relating the total acoustic emission to the test stress.

  9. Literature Reviews on Modeling Internal Geometry of Textile Composites and Rate-Independent Continuum Damage

    Science.gov (United States)

    Su-Yuen, Hsu

    2011-01-01

    Textile composite materials have good potential for constructing composite structures where the effects of three-dimensional stresses are critical or geometric complexity is a manufacturing concern. There is a recent interest in advancing competence within Langley Research Center for modeling the degradation of mechanical properties of textile composites. In an initial effort, two critical areas are identified to pursue: (1) Construction of internal geometry of textile composites, and (2) Rate-independent continuum damage mechanics. This report documents reviews on the two subjects. Various reviewed approaches are categorized, their assumptions, methods, and progress are briefed, and then critiques are presented. Each review ends with recommended research.

  10. Diagnostic value of the 2011 International Federation for Cervical Pathology and Colposcopy Terminology in predicting cervical lesions

    Science.gov (United States)

    Zhang, Liqin; Yan, Ye; Han, Cha; Xue, Fengxia

    2018-01-01

    Objective To evaluate the diagnostic accuracy of the 2011 International Federation for Cervical Pathology and Colposcopy (IFCPC) colposcopic terminology. Methods The clinicopathological data of 2262 patients who underwent colposcopy from September 2012 to September 2016 were reviewed. The colposcopic findings, colposcopic impression, and cervical histopathology of the patients were analyzed. Correlations between variables were evaluated using cervical histopathology as the gold standard. Results Colposcopic diagnosis matched biopsy histopathology in 1482 patients (65.5%), and the weighted kappa strength of agreement was 0.480 (Pterminology can improve the diagnostic accuracy for all lesion severities. The categorization of major changes and minor changes is appropriate. However, colposcopic diagnosis remains unsatisfactory. Poor reproducibility of type 2 transformation zone and the significance of leukoplakia require further study. PMID:29507681

  11. Image data compression in diagnostic imaging. International literature review and workflow recommendation

    International Nuclear Information System (INIS)

    Braunschweig, R.; Kaden, Ingmar; Schwarzer, J.; Sprengel, C.; Klose, K.

    2009-01-01

    Purpose: Today healthcare policy is based on effectiveness. Diagnostic imaging became a ''pace-setter'' due to amazing technical developments (e.g. multislice CT), extensive data volumes, and especially the well defined workflow-orientated scenarios on a local and (inter)national level. To make centralized networks sufficient, image data compression has been regarded as the key to a simple and secure solution. In February 2008 specialized working groups of the DRG held a consensus conference. They designed recommended data compression techniques and ratios. Material und methoden: The purpose of our paper is an international review of the literature of compression technologies, different imaging procedures (e.g. DR, CT etc.), and targets (abdomen, etc.) and to combine recommendations for compression ratios and techniques with different workflows. The studies were assigned to 4 different levels (0-3) according to the evidence. 51 studies were assigned to the highest level 3. Results: We recommend a compression factor of 1: 8 (excluding cranial scans 1:5). For workflow reasons data compression should be based on the modalities (CT, etc.). PACS-based compression is currently possible but fails to maximize workflow benefits. Only the modality-based scenarios achieve all benefits. (orig.)

  12. Image data compression in diagnostic imaging. International literature review and workflow recommendation

    Energy Technology Data Exchange (ETDEWEB)

    Braunschweig, R.; Kaden, Ingmar [Klinik fuer Bildgebende Diagnostik und Interventionsradiologie, BG-Kliniken Bergmannstrost Halle (Germany); Schwarzer, J.; Sprengel, C. [Dept. of Management Information System and Operations Research, Martin-Luther-Univ. Halle Wittenberg (Germany); Klose, K. [Medizinisches Zentrum fuer Radiologie, Philips-Univ. Marburg (Germany)

    2009-07-15

    Purpose: Today healthcare policy is based on effectiveness. Diagnostic imaging became a ''pace-setter'' due to amazing technical developments (e.g. multislice CT), extensive data volumes, and especially the well defined workflow-orientated scenarios on a local and (inter)national level. To make centralized networks sufficient, image data compression has been regarded as the key to a simple and secure solution. In February 2008 specialized working groups of the DRG held a consensus conference. They designed recommended data compression techniques and ratios. Material und methoden: The purpose of our paper is an international review of the literature of compression technologies, different imaging procedures (e.g. DR, CT etc.), and targets (abdomen, etc.) and to combine recommendations for compression ratios and techniques with different workflows. The studies were assigned to 4 different levels (0-3) according to the evidence. 51 studies were assigned to the highest level 3. Results: We recommend a compression factor of 1: 8 (excluding cranial scans 1:5). For workflow reasons data compression should be based on the modalities (CT, etc.). PACS-based compression is currently possible but fails to maximize workflow benefits. Only the modality-based scenarios achieve all benefits. (orig.)

  13. A study to establish international diagnostic reference levels for paediatric computed tomography

    International Nuclear Information System (INIS)

    Vassileva, J.; Rehani, M.; Kostova-Lefterova, D.; Al-Naemi, H.M.; Al Suwaidi, J.S.; Arandjic, D.; Bashier, E.H.O.; Kodlulovich Renha, S.; El-Nachef, L.; Aguilar, J.G.; Gershan, V.; Gershkevitsh, E.; Gruppetta, E.; Hustuc, A.; Jauhari, A.; Hassan Kharita, Mohammad; Khelassi-Toutaoui, N.; Khosravi, H.R.; Khoury, H.; Kralik, I.; Mahere, S.; Mazuoliene, J.; Mora, P.; Muhogora, W.; Muthuvelu, P.; Nikodemova, D.; Novak, L.; Pallewatte, A.; Pekarovic, D.; Shaaban, M.; Shelly, E.; Stepanyan, K.; Thelsy, N.; Visrutaratna, P.; Zaman, A.

    2015-01-01

    The article reports results from the largest international dose survey in paediatric computed tomography (CT) in 32 countries and proposes international diagnostic reference levels (DRLs) in terms of computed tomography dose index (CTDI vol ) and dose length product (DLP). It also assesses whether mean or median values of individual facilities should be used. A total of 6115 individual patient data were recorded among four age groups: <1 y, >1-5 y, >5-10 y and >10-15 y. CTDI w , CTDI vol and DLP from the CT console were recorded in dedicated forms together with patient data and technical parameters. Statistical analysis was performed, and international DRLs were established at rounded 75. percentile values of distribution of median values from all CT facilities. The study presents evidence in favour of using median rather than mean of patient dose indices as the representative of typical local dose in a facility, and for establishing DRLs as third quartile of median values. International DRLs were established for paediatric CT examinations for routine head, chest and abdomen in the four age groups. DRLs for CTDI vol are similar to the reference values from other published reports, with some differences for chest and abdomen CT. Higher variations were observed between DLP values, based on a survey of whole multi-phase exams. It may be noted that other studies in literature were based on single phase only. DRLs reported in this article can be used in countries without sufficient medical physics support to identify non-optimised practice. Recommendations to improve the accuracy and importance of future surveys are provided. (authors)

  14. Assessing the damage importance rank in acoustic diagnostics of technical conditions of the internal combustion engine with multi-valued logical decision trees

    Directory of Open Access Journals (Sweden)

    Deptuła Adam

    2017-01-01

    Full Text Available This paper presents possible applications of acoustic diagnostics in inspecting the technical condition of an internal combustion engine with autoignition on the example of the Fiat drive unit with the common rail system. As a result of measuring the sound pressure level for specific faults and comparing the noise generated by the motor running smoothly, the detailed maps of changes in the acoustic spectrum may be generated. These results may be helpful in future diagnostics of internal combustion engines. In the paper, we present the results from the scientific works in the area of research, design and operation of internal combustion engines, conducted at the Department of Automotive Engineering, in cooperation with the Laboratory of Hydraulic Drives & Vibroacoustics of Machines at the Wroclaw University of Technology. The broader study has so far allowed us to develop an authoritative method of identifying the type of engine damage using gametree structures. The present works assess the possibility of using multi-valued logic trees.

  15. Developing Large-Scale Bayesian Networks by Composition: Fault Diagnosis of Electrical Power Systems in Aircraft and Spacecraft

    Science.gov (United States)

    Mengshoel, Ole Jakob; Poll, Scott; Kurtoglu, Tolga

    2009-01-01

    In this paper, we investigate the use of Bayesian networks to construct large-scale diagnostic systems. In particular, we consider the development of large-scale Bayesian networks by composition. This compositional approach reflects how (often redundant) subsystems are architected to form systems such as electrical power systems. We develop high-level specifications, Bayesian networks, clique trees, and arithmetic circuits representing 24 different electrical power systems. The largest among these 24 Bayesian networks contains over 1,000 random variables. Another BN represents the real-world electrical power system ADAPT, which is representative of electrical power systems deployed in aerospace vehicles. In addition to demonstrating the scalability of the compositional approach, we briefly report on experimental results from the diagnostic competition DXC, where the ProADAPT team, using techniques discussed here, obtained the highest scores in both Tier 1 (among 9 international competitors) and Tier 2 (among 6 international competitors) of the industrial track. While we consider diagnosis of power systems specifically, we believe this work is relevant to other system health management problems, in particular in dependable systems such as aircraft and spacecraft. (See CASI ID 20100021910 for supplemental data disk.)

  16. Performance of Different Diagnostic Criteria for Familial Mediterranean Fever in Children with Periodic Fevers : Results from a Multicenter International Registry

    NARCIS (Netherlands)

    Demirkaya, Erkan; Saglam, Celal; Turker, Turker; Koné-Paut, Isabelle; Woo, Pat; Doglio, Matteo; Amaryan, Gayane; Frenkel, Joost; Uziel, Yosef; Insalaco, Antonella; Cantarini, Luca; Hofer, Michael; Boiu, Sorina; Duzova, Ali; Modesto, Consuelo; Bryant, Annette; Rigante, Donato; Papadopoulou-Alataki, Efimia; Guillaume-Czitrom, Severine; Kuemmerle-Deschner, Jasmine; Neven, Bénédicte; Lachmann, Helen; Martini, Alberto; Ruperto, Nicolino; Gattorno, Marco; Ozen, Seza

    2015-01-01

    OBJECTIVE: Our aims were to validate the pediatric diagnostic criteria in a large international registry and to compare them with the performance of previous criteria for the diagnosis of familial Mediterranean fever (FMF). METHODS: Pediatric patients with FMF from the Eurofever registry were used

  17. Expanding the Operational Limits of the Single-Point Impedance Diagnostic for Internal Temperature Monitoring of Lithium-ion Batteries

    International Nuclear Information System (INIS)

    Spinner, Neil S.; Love, Corey T.; Rose-Pehrsson, Susan L.; Tuttle, Steven G.

    2015-01-01

    Highlights: • Single-point impedance diagnostic technique demonstrated for lithium-ion batteries • Correlation between imaginary impedance and internal temperature determined • Instantaneous monitoring of commercial lithium-ion battery internal temperature • Expanded temperature range from −10°C up to 95°C • Non-invasive method useful for practical temperature monitoring of commercial cells - Abstract: Instantaneous internal temperature monitoring of a commercial 18650 LiCoO 2 lithium-ion battery was performed using a single-point EIS measurement. A correlation between the imaginary impedance, –Z imag , and internal temperature at 300 Hz was developed that was independent of the battery’s state of charge. An Arrhenius-type dependence was applied, and the activation energy for SEI ionic conductivity was found to be 0.13 eV. Two separate temperature-time experiments were conducted with different sequences of temperature, and single-point impedance tests at 300 Hz were performed to validate the correlation. Limitations were observed with the upper temperature range (68°C < T < 95°C), and consequently a secondary, empirical fit was applied for this upper range to improve accuracy. Average differences between actual and fit temperatures decreased around 3-7°C for the upper range with the secondary correlation. The impedance response at this frequency corresponded to the anode/SEI layer, and the SEI is reported to be thermally stable up to around 100°C, at which point decomposition may occur leading to battery deactivation and/or total failure. It is therefore of great importance to be able to track internal battery temperatures up to this critical point of 100°C, and this work demonstrates an expansion of the single-point EIS diagnostic to these elevated temperatures

  18. Application of the new International Code of Practice for dosimetry in diagnostic radiology to conventional exams

    International Nuclear Information System (INIS)

    Martinez Gonzalez, A.; Cardenas Herrera, J.; Walwyn Salas, G.; Machado, A.; Mora Machado, R. de la

    2008-01-01

    Full text: During the recent years, a policy for updating and installation of the X-ray equipment, specialized as well as conventional, have been carrying out, in Cuba. Conventional equipment has reached almost the whole primary level. Considering this situation, the quality control programs and clinical dosimetry have become even more important. Regarding the last one, an International Code of Practice for Dosimetry in Diagnostic Radiology had been published by the International Atomic Energy Agency in order to been used as a guide and to standardize the methodologies used to evaluate the patient exposure in radiodiagnostic. Taken into consideration the above reasons, an assessment of the aforementioned code of practice was done in order to choose the most feasible methodology to implement in the country. The evaluation was performed considering the lack of dosimetric equipment and medical physicists in this practice, in the interests of increasing the measurements scope to a large number of services as well as to standardize the methodology on a national scale. The present work shows the results obtained from the application of the new code of practice to conventional radiology exams in some medical institutions. Out of 3 on patients measurements methodologies described in the code of practice, the one of measurement of the incident air kerma was chosen. This methodology allow to the physicist to focus on the diagnostic equipment tests and to delegate the collection of the patient and exposure parameters data to the technicians, which make the increased of the patient and diagnostic departments sample, possible. The measurements were carried out in 2 hospital of the capital. The exams involved in the assessments were thorax PA, lumbar spine AP and lumbar spine LAT. In every diagnostic service, 25 patients were chosen on each projection. The weight and height average of the patient sample were 68 kg and 167 cm respectively. In the assessment were considered only

  19. Size-confined fixed-composition and composition-dependent engineered band gap alloying induces different internal structures in L-cysteine-capped alloyed quaternary CdZnTeS quantum dots

    Science.gov (United States)

    Adegoke, Oluwasesan; Park, Enoch Y.

    2016-06-01

    The development of alloyed quantum dot (QD) nanocrystals with attractive optical properties for a wide array of chemical and biological applications is a growing research field. In this work, size-tunable engineered band gap composition-dependent alloying and fixed-composition alloying were employed to fabricate new L-cysteine-capped alloyed quaternary CdZnTeS QDs exhibiting different internal structures. Lattice parameters simulated based on powder X-ray diffraction (PXRD) revealed the internal structure of the composition-dependent alloyed CdxZnyTeS QDs to have a gradient nature, whereas the fixed-composition alloyed QDs exhibited a homogenous internal structure. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) analysis confirmed the size-confined nature and monodispersity of the alloyed nanocrystals. The zeta potential values were within the accepted range of colloidal stability. Circular dichroism (CD) analysis showed that the surface-capped L-cysteine ligand induced electronic and conformational chiroptical changes in the alloyed nanocrystals. The photoluminescence (PL) quantum yield (QY) values of the gradient alloyed QDs were 27-61%, whereas for the homogenous alloyed QDs, the PL QY values were spectacularly high (72-93%). Our work demonstrates that engineered fixed alloying produces homogenous QD nanocrystals with higher PL QY than composition-dependent alloying.

  20. The effect of question format and task difficulty on reasoning strategies and diagnostic performance in Internal Medicine residents.

    Science.gov (United States)

    Heemskerk, Laura; Norman, Geoff; Chou, Sophia; Mintz, Marcy; Mandin, Henry; McLaughlin, Kevin

    2008-11-01

    Previous studies have suggested an association between reasoning strategies and diagnostic success, but the influence on this relationship of variables such as question format and task difficulty, has not been studied. Our objective was to study the association between question format, task difficulty, reasoning strategies and diagnostic success. Study participants were 13 Internal Medicine residents at the University of Calgary. Each was given eight problem-solving questions in four clinical presentations and were randomized to groups that differed only in the question format, such that a question presented as short answer (SA) to the first group was presented as extended matching (EM) to the second group. There were equal numbers of SA/EM questions and straightforward/difficult tasks. Participants performed think-aloud during diagnostic reasoning. Data were analyzed using multiple logistic regression. Question format was associated with reasoning strategies; hypothetico-deductive reasoning being used more frequently on EM questions and scheme-inductive reasoning on SA questions. For SA question, non-analytic reasoning alone was used more frequently to answer straightforward cases than difficult cases, whereas for EM questions no such association was observed. EM format and straightforward task increased the odds of diagnostic success, whereas hypothetico-deductive reasoning was associated with reduced odds of success. Question format and task difficulty both influence diagnostic reasoning strategies and studies that examine the effect of reasoning strategies on diagnostic success should control for these effects. Further studies are needed to investigate the effect of reasoning strategies on performance of different groups of learners.

  1. The Internal, External, and Diagnostic Validity of Sluggish Cognitive Tempo: A Meta-Analysis and Critical Review

    Science.gov (United States)

    Becker, Stephen P.; Leopold, Daniel R.; Burns, G. Leonard; Jarrett, Matthew A.; Langberg, Joshua M.; Marshall, Stephen A.; McBurnett, Keith; Waschbusch, Daniel A.; Willcutt, Erik G.

    2015-01-01

    , although there is initial support for SCT being associated with processing speed, sustained attention, and metacognitive deficits. Conclusion This meta-analytic review provides strong support for the internal validity of SCT and preliminary support for the external validity of SCT. In terms of diagnostic validity, there is not currently enough evidence to describe SCT in diagnostic terms. Key directions for future research are discussed, including evaluating the conceptualization of SCT as a transdiagnostic construct and the need for longitudinal research. PMID:26903250

  2. Fibre Reinforced Polymer Composites as Internal and External Reinforcements for Building Elements

    Directory of Open Access Journals (Sweden)

    Cătălin Banu

    2008-01-01

    Full Text Available During the latest decades fibre reinforced polymer (FRP composite materials have proven valuable properties and suitable to be used in construction of new buildings and in upgrading the existing ones. These materials have covered the road from research laboratory and demonstration projects to implementation in actual structures. Nowadays the civil and structural engineering communities are about to commence the stage in which the use of FRP composites is becoming a routine similar to that of traditional material such as concrete, masonry and wood. Two main issues are presented in this paper, the use of FRP composite materials for new structural members (internal reinforcements and strengthening of existing members (externally bonded reinforcements. The advantages and disadvantages as well as the problems and constraints associated with both issues are discussed in detail mainly related to concrete members.

  3. Implementation of the International Code of Practice on Dosimetry in Diagnostic Radiology (TRS 457): Review of Test Results

    International Nuclear Information System (INIS)

    2011-01-01

    In 2007, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (IAEA Technical Reports Series No. 457). This publication recommends procedures for calibration and dosimetric measurement for the attainment of standardized dosimetry. It also addresses requirements both in standards dosimetry laboratories, especially Secondary Standards Dosimetry Laboratories (SSDLs), and in clinical centres for radiology, as found in most hospitals. The implementation of TRS No. 457 decreases the uncertainty in the dosimetry of diagnostic radiology beams and provides Member States with a unified and consistent framework for dosimetry in diagnostic radiology, which previously did not exist. A coordinated research project (CRP E2.10.06) was established in order to provide practical guidance to professionals at SSDLs and to clinical medical physicists on the implementation of TRS No. 457. This includes the calibration of radiological dosimetry instrumentation, the dissemination of calibration coefficients to clinical centres and the establishment of dosimetric measurement processes in clinical settings. The main goals of the CRP were to: Test the procedures recommended in TRS No. 457 for calibration of radiation detectors in different types of diagnostic beams and measuring instruments for varying diagnostic X ray modalities; Test the clinical dosimetry procedures, including the use of phantoms and patient dose surveys; Report on the practical implementation of TRS No. 457 at both SSDLs and hospital sites. Testing of TRS No. 457 was performed by a group of medical physicists from hospitals and SSDLs from various institutions worldwide

  4. MO-DE-204-00: International Symposium: Patient Dose Reduction in Diagnostic Radiology

    International Nuclear Information System (INIS)

    2016-01-01

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented. Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend

  5. MO-DE-204-00: International Symposium: Patient Dose Reduction in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    The main topic of the session is to show how dose optimization is being implemented in various regions of the world, including Europe, Australia, North America and other regions. A multi-national study conducted under International Atomic Energy Agency (IAEA) across more than 50 less resourced countries gave insight into patient radiation doses and safety practices in CT, mammography, radiography and interventional procedures, both for children and adults. An important outcome was the capability development on dose assessment and management. An overview of recent European projects related to CT radiation dose and optimization both to adults and children will be presented. Existing data on DRLs together with a European methodology proposed on establishing and using DRLs for paediatric radiodiagnostic imaging and interventional radiology practices will be shown. Compared with much of Europe at least, many Australian imaging practices are relatively new to the task of diagnostic imaging dose optimisation. In 2008 the Australian Government prescribed a requirement to periodically compare patient radiation doses with diagnostic reference levels (DRLs), where DRLs have been established. Until recently, Australia had only established DRLs for computed tomography (CT). Regardless, both professional society and individual efforts to improved data collection and develop optimisation strategies across a range of modalities continues. Progress in this field, principally with respect to CT and interventional fluoroscopy will be presented. In the US, dose reduction and optimization efforts for computed tomography have been promoted and mandated by several organizations and accrediting entities. This presentation will cover the general motivation, implementation, and implications of such efforts. Learning Objectives: Understand importance of the dose optimization in Diagnostic Radiology. See how this goal is achieved in different regions of the World. Learn about the global trend

  6. Social anxiety disorder diagnostic criteria perform equally across age, comorbid diagnosis, and performance/interaction subtypes.

    Science.gov (United States)

    Crome, Erica; Baillie, Andrew

    2015-01-01

    The prevalence of social anxiety disorder (SAD) is frequently higher in younger age groups and people with other anxiety or mood disorders; however, it is unclear whether these groups have a higher risk for developing SAD or are simply more likely to endorse diagnostic criteria than other people with similar levels of social anxiety. Explicitly testing the assumption all people respond to structured diagnostic interviews in comparable ways (measurement invariance) is essential in ensuring systematic response biases do not create spurious group differences. This research aims to systematically test whether age, comorbidity status, or types of social fears affect responses to a structured diagnostic interview. Responses from 1755 participants in a large-scale survey of mental health in Australia screening into the social phobia/SAD section of the Composite International Diagnostic Interview were used. Three series of multigroup confirmatory factor analyses for categorical data systematically tested for increasingly strict levels of measurement invariance. Overall, patterns of responding to diagnostic criteria were comparable across the groups, supporting assumptions of measurement invariance. Establishment of invariance supports the interpretation of differences between age, comorbidity status, and types of social situations feared as genuine differences in experience as opposed to measurement biases.

  7. Polychromatic holographic plasma diagnostics

    International Nuclear Information System (INIS)

    Zhiglinskij, A.G.; Morozov, A.O.

    1992-01-01

    Review of holographic interferometry properties is performed and advantages of this method by plasma diagnostics are indicated. Main results obtained by the method of holographic interferometry in studies of various-type plasmas are considered. Special attention is paid to multiwave plasma diagnostics, the necessity of which is related as a rule to multicomponent composition of plasma. The eight laser and gas-discharge sources and holographic schemes, which make it possible to realize plasma polychromatic and holographic interferometry, are considered. The advantages of the method are demonstrated by examples of polychromatic holographic diagnostics of arc discharge and discharge in a hollow cathode. Review of theoretical works determining the applicability area of resonance polychromatic interferometry is carried out

  8. [Cognitive errors in diagnostic decision making].

    Science.gov (United States)

    Gäbler, Martin

    2017-10-01

    Approximately 10-15% of our diagnostic decisions are faulty and may lead to unfavorable and dangerous outcomes, which could be avoided. These diagnostic errors are mainly caused by cognitive biases in the diagnostic reasoning process.Our medical diagnostic decision-making is based on intuitive "System 1" and analytical "System 2" diagnostic decision-making and can be deviated by unconscious cognitive biases.These deviations can be positively influenced on a systemic and an individual level. For the individual, metacognition (internal withdrawal from the decision-making process) and debiasing strategies, such as verification, falsification and rule out worst-case scenarios, can lead to improved diagnostic decisions making.

  9. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    Science.gov (United States)

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  10. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  11. Entrapment of Radionuclides in Nanoparticle Compositions

    DEFF Research Database (Denmark)

    2012-01-01

    The present invention is directed to the technical field of imaging compositions useful for diagnosing cancer and other diseases in a subject. In particular, the invention relates to a class of diagnostic compounds comprising a novel liposome composition with encapsulated metal entities such as r...... tissue and, in general, pathological conditions associated with leaky blood vessels. The present invention provides a new diagnostic tool for the utilization of positron emission tomography (PET) imaging technique.......The present invention is directed to the technical field of imaging compositions useful for diagnosing cancer and other diseases in a subject. In particular, the invention relates to a class of diagnostic compounds comprising a novel liposome composition with encapsulated metal entities...... such as radionuclides,for example 61Cu and 64Cu copper isotopes. The invention further relates to a novel method for loading delivery systems, such as liposome compositions, with metal entities such as radionuclides, and the use of liposomes for targeted diagnosis and treatment of a target site, such as cancerous...

  12. Diagnosing holographic type dark energy models with the Statefinder hierarchy, composite null diagnostic and w- w' pair

    Science.gov (United States)

    Zhao, Ze; Wang, Shuang

    2018-03-01

    The main purpose of this work is to distinguish various holographic type dark energy (DE) models, including the ΛHDE, HDE, NADE, and RDE model, by using various diagnostic tools. The first diagnostic tool is the Statefinder hierarchy, in which the evolution of Statefinder hierarchy parmeter S (1) 3( z) and S (1) 4( z) are studied. The second is composite null diagnostic (CND), in which the trajectories of { S (1) 3, ɛ} and { S (1) 4, ɛ} are investigated, where ɛ is the fractional growth parameter. The last is w-w' analysis, where w is the equation of state for DE and the prime denotes derivative with respect to ln a. In the analysis we consider two cases: varying current fractional DE density Ω de0 and varying DE model parameter C. We find that: (1) both the Statefinder hierarchy and the CND have qualitative impact on ΛHDE, but only have quantitative impact on HDE. (2) S (1) 4 can lead to larger differences than S (1) 3, while the CND pair has a stronger ability to distinguish different models than the Statefinder hierarchy. (3) For the case of varying C, the { w,w'} pair has qualitative impact on ΛHDE; for the case of varying Ω de0, the { w, w'} pair only has quantitative impact; these results are different from the cases of HDE, RDE, and NADE, in which the {w,w'} pair only has quantitative impact on these models. In conclusion, compared with HDE, RDE, and NADE, the ΛHDE model can be easily distinguished by using these diagnostic tools.

  13. Bayesian analysis of ion beam diagnostics

    International Nuclear Information System (INIS)

    Toussaint, U. von; Fischer, R.; Dose, V.

    2001-01-01

    Ion beam diagnostics are routinely used for quantitative analysis of the surface composition of mixture materials up to a depth of a few μm. Unfortunately, advantageous properties of the diagnostics, like high depth resolution in combination with a large penetration depth, no destruction of the surface, high sensitivity for large as well as for small atomic numbers, and high sensitivity are mutually exclusive. Among other things, this is due to the ill-conditioned inverse problem of reconstructing depth distributions of the composition elements. Robust results for depth distributions are obtained with adaptive methods in the framework of Bayesian probability theory. The method of adaptive kernels allows for distributions which contain only the significant information of the data while noise fitting is avoided. This is achieved by adaptively reducing the degrees of freedom supporting the distribution. As applications for ion beam diagnostics Rutherford backscattering spectroscopy and particle induced X-ray emission are shown

  14. Complex regional pain syndrome type I : Use of the International Association for the Study of Pain diagnostic criteria defined in 1994

    NARCIS (Netherlands)

    Reinders, M.F.; Geertzen, J.H.B.; Dijkstra, P.U.

    2002-01-01

    Objectives: The objective was to assess the reported use in recent publications of the diagnostic criteria for complex regional pain syndrome type I (CRPS 1) proposed by the International Association for the Study of Pain (IASP) in 1994. Methods: A literature search of MEDLINE (January 1996 to July

  15. Sequential fault diagnosis for mechatronics system using diagnostic hybrid bond graph and composite harmony search

    Directory of Open Access Journals (Sweden)

    Ming Yu

    2015-12-01

    Full Text Available This article proposes a sequential fault diagnosis method to handle asynchronous distinct faults using diagnostic hybrid bond graph and composite harmony search. The faults under consideration include fault mode, abrupt fault, and intermittent fault. The faults can occur in different time instances, which add to the difficulty of decision making for fault diagnosis. This is because the earlier occurred fault can exhibit fault symptom which masks the fault symptom of latter occurred fault. In order to solve this problem, a sequential identification algorithm is developed in which the identification task is reactivated based on two conditions. The first condition is that the latter occurred fault has at least one inconsistent coherence vector element which is consistent in coherence vector of the earlier occurred fault, and the second condition is that the existing fault coherence vector has the ability to hide other faults and the second-level residual exceeds the threshold. A new composite harmony search which is capable of handling continuous variables and binary variables simultaneously is proposed for identification purpose. Experiments on a mobile robot system are conducted to assess the proposed sequential fault diagnosis algorithm.

  16. Diagnostic Imaging Workshop

    International Nuclear Information System (INIS)

    Sociedad Argentina de Fisica Medica

    2012-01-01

    The American Association of Physicist in Medicine (AAPM), the International Organization for Medical Physics (IOMP) and the Argentina Society of Medical Physics (SAFIM) was organized the Diagnostic Imaging Workshop 2012, in the city of Buenos Aires, Argentina. This workshop was an oriented training and scientific exchange between professionals and technicians who work in medical physics, especially in the areas of diagnostic imaging, nuclear medicine and radiotherapy, with special emphasis on the use of multimodal imaging for radiation treatment, planning as well of quality assurance associates.

  17. Development of new diagnostics for WEST

    International Nuclear Information System (INIS)

    Lotte, P.; Moreau, P.; Gil, C.

    2015-01-01

    WEST, the upgraded superconducting tokamak Tore Supra, will be an international experimental platform aimed to support ITER Physics program. The main objective of WEST is to provide relevant plasma conditions for validating plasma facing component (PFC) technology, in particular the actively cooled Tungsten divertor monoblocks, and also assessing high heat flux and high fluence plasma wall interactions with Tungsten in order to prepare ITER divertor operation. In parallel, WEST will also open new experimental opportunities for developing integrated H mode operation and exploring steady state scenarios in a metallic environment. In order to fulfil the Scientific Program of WEST, new diagnostics have been developed in addition to the already existing diagnostics of Tore Supra, modified and improved during the shutdown. For the PFC technology validation program, new tools have been implemented, like a full infrared survey of the PFC, a new calorimetry system, local temperature measurements (thermocouple and Bragg grating optical fiber), and several sets of Langmuir probes. For the analysis of long pulse H mode operation, new plasma diagnostics will be implemented, among which the Visible Spectroscopy diagnostic for W sources and transport studies, the Soft-Xray diagnostic based on gas electron multiplier detectors for transport and MHD studies, the X-ray imaging crystal spectroscopy diagnostic with advanced solid state detector properties for ion temperature, ion density and plasma rotation velocity measurements, and the ECE Imaging diagnostic for MHD and turbulence studies. Most of these new diagnostics are developed with the participation of French Universities or through international collaborations. This paper focuses on the description of these four plasma diagnostics. (author)

  18. Atomic structures and compositions of internal interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Seidman, D.N. (Northwestern Univ., Evanston, IL (United States). Dept. of Materials Science and Engineering); Merkle, K.L. (Argonne National Lab., IL (United States))

    1992-03-01

    This research program addresses fundamental questions concerning the relationships between atomic structures and chemical compositions of metal/ceramic heterophase interfaces. The chemical composition profile across a Cu/MgO {l brace}111{r brace}-type heterophase interface, produced by the internal oxidation of a Cu(Mg) single phase alloy, is measured via atom-probe field-ion microscopy with a spatial resolution of 0.121 nm; this resolution is equal to the interplanar space of the {l brace}222{r brace} MgO planes. In particular, we demonstrate for the first time that the bonding across a Cu/MgO {l brace}111{r brace}-type heterophase interface, along a <111> direction common to both the Cu matrix and an MgO precipitate, has the sequence Cu{vert bar}O{vert bar}Mg{hor ellipsis} and not Cu{vert bar}Mg{vert bar}O{hor ellipsis}; this result is achieved without any deconvolution of the experimental data. Before determining this chemical sequence it was established, via high resolution electron microscopy, that the morphology of an MgO precipitate in a Cu matrix is an octahedron faceted on {l brace}111{r brace} planes with a cube-on-cube relationship between a precipitate and the matrix. First results are also presented for the Ni/Cr{sub 2}O{sub 4} interface; for this system selected area atom probe microscopy was used to analyze this interface; Cr{sub 2}O{sub 4} precipitates are located in a field-ion microscope tip and a precipitate is brought into the tip region via a highly controlled electropolishing technique.

  19. Background and perspective on rapid progress and deepening of international development of nuclear industry-composition of international nuclear energy business 'cooperation and competition'

    International Nuclear Information System (INIS)

    Kano, Tokio; Kanda, Keji; Ishizuka, Nobuo

    2005-01-01

    Based on the recognition that international development of nuclear industry was important by a viewpoint of international cooperation to neighboring Asian area and also it was the trump that defeated a feeling of domestic confinement, the Japan Atomic Industrial Forum (JAIF) founded Nuclear energy international development gathering' in November 2004. On that occasion our magazine (March, 2005 issue) featured 'prospects and problem of the international development of nuclear energy use'. Slightly for half a year afterwards this nuclear energy international development has been rapidly deepened and become a close-up as a policy of an important strategy of the field of nuclear energy that the government and the private sector were united to make. Therefore the nuclear energy international development was secondly featured from multidirectional points of view such as a background of nuclear energy international development, composition of international nuclear energy business, a main strategy of three makers, approach of finance / a business firm. (T. Tanaka)

  20. International differences in health care costs in Europe and the United States: Do these affect the cost-effectiveness of diagnostic strategies for pulmonary embolism?

    International Nuclear Information System (INIS)

    Erkel, A.R. van; Pattynama, P.M.T.; Hout, W.B. van den

    1999-01-01

    The aim of this study was to assess whether potential differences in costs for diagnostic procedures and treatment of pulmonary embolism (PE) among European and U. S. hospitals alter the optimal cost-effective diagnostic strategy for PE. A standardized questionnaire was used to obtain cost data for the diagnosis and treatment of PE in participating European and U. S. hospitals. Costs for diagnostic tests and treatment of PE were then calculated in a standardized manner for all participating hospitals, from the hospital perspective. Costs were used in an existing cost-effectiveness analysis (CEA) model to determine the most cost-effective diagnostic strategy in participating hospitals. There were considerable differences in costs for diagnostic and therapeutic procedures for PE among the participating centers. These differences, however, did not affect the most cost-effective strategy based on incremental cost-effectiveness. In all hospitals the most cost-effective strategy appeared to be ultrasound followed by helical CT. International differences in cost of diagnostic and therapeutic procedures certainly exist and should be considered before applying a published CEA. Nevertheless, despite these cost differences, the diagnostic strategy for PE of ultrasound followed by helical CT appears most cost-effective. (orig.)

  1. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  2. Control of internal and external short circuits in lithium batteries using a composite thermal switch

    Science.gov (United States)

    Mcdonald, Robert C.; Pickett, Jerome; Goebel, Franz

    1991-01-01

    A composite material has been developed, consisting of a blend of metal and fluorocarbon particles, which behaves as an electronic conductor at room temperature and which abruptly becomes an insulator at a predetermined temperature. This switching behavior results from the difference in thermal expansion coefficients between the conductive and non-conductive portions of the composite. This material was applied as a thin film between the carbon cathode in Li/SOCl2 cells, and the metallic cathode current collector. Using test articles incorporating this feature it was shown that lithium cells externally heated or internally heated during a short circuit lost rate capability and the ability to overheat well below the melting point of lithium (180 C). Thus, during an internal or external cell short circuit, the potential for thermal runaway involving reactions of molten lithium is avoided.

  3. Accuracy of the Composite International Diagnostic Interview (CIDI 2.1 for diagnosis of post-traumatic stress disorder according to DSM-IV criteria Validade do diagnóstico de transtorno de estresse pós-traumático do Composite International Diagnostic Interview (CIDI 2.1 de acordo com os critérios diagnósticos da DSM-IV

    Directory of Open Access Journals (Sweden)

    Maria Inês Quintana

    2012-07-01

    Full Text Available The objective was to study the accuracy of the post-traumatic stress disorder (PTSD section of the Composite International Diagnostic Interview (CIDI 2.1 DSM-IV diagnosis, using the Structured Clinical Interview (SCID as gold standard, and compare the ICD-10 and DSM IV classifications for PTSD. The CIDI was applied by trained lay interviewers and the SCID by a psychologist. The subjects were selected from a community and an outpatient program. A total of 67 subjects completed both assessments. Kappa coefficients for the ICD-10 and the DSM IV compared to the SCID diagnosis were 0.67 and 0.46 respectively. Validity for the DSM IV diagnosis was: sensitivity (51.5%, specificity (94.1%, positive predictive value (9.5%, negative predictive value (66.7%, misclassification rate (26.9%. The CIDI 2.1 demonstrated low validity coefficients for the diagnosis of PTSD using DSM IV criteria when compared to the SCID. The main source of discordance in this study was found to be the high probability of false-negative cases with regards to distress and impairment as well as to avoidance symptoms.O objetivo deste artigo foi estudar a validade concorrente da seção de transtorno de estresse pós-traumático do CIDI 2.1 critérios DSM IV, utilizando o Structured Clinical Interview (SCID como padrão-ouro, e comparar o diagnóstico de TEPT entre CID-10 e DSM IV. O CIDI foi aplicado por entrevistadores leigos treinados e o SCID por uma psicóloga. A amostra foi composta por sujeitos da comunidade e de um ambulatório de especialidade psiquiátrica. Sessenta e sete sujeitos completaram ambos os questionários. O coeficiente kappa foi de 0.46 ao comparar DSM IV com a SCID. A validade diagnóstica usando critérios do DSM IV foi de: sensibilidade = 51.5%, especificidade = 94.1%, valor preditivo positivo = 89.5%, valor preditivo negativo = 66.7%, taxa de classificação incorreta = 26.9%. O CIDI 2.1 apresentou valores baixos para os coeficientes de validação de TEPT

  4. PREFACE: International Conference on Structural Nano Composites (NANOSTRUC 2012)

    Science.gov (United States)

    Njuguna, James

    2012-09-01

    Dear Colleagues It is a great pleasure to welcome you to NanoStruc2012 at Cranfield University. The purpose of the 2012 International Conference on Structural Nano Composites (NanoStruc2012) is to promote activities in various areas of materials and structures by providing a forum for exchange of ideas, presentation of technical achievements and discussion of future directions. NanoStruc brings together an international community of experts to discuss the state-of-the-art, new research results, perspectives of future developments, and innovative applications relevant to structural materials, engineering structures, nanocomposites, modelling and simulations, and their related application areas. The conference is split in 7 panel sessions, Metallic Nanocomposites and Coatings, Silica based Nanocomposites, safty of Nanomaterials, Carboin based Nanocomposites, Multscale Modelling, Bio materials and Application of Nanomaterials. All accepted Papers will be published in the IOP Conference Series: Materials Science and Engineering (MSE), and included in the NanoStruc online digital library. The abstracts will be indexed in Scopus, Compedex, Inspec, INIS (International Nuclear Information System), Chemical Abstracts, NASA Astrophysics Data System and Polymer Library. Before ending this message, I would like to acknowledge the hard work, professional skills and efficiency of the team which ensured the general organisation. As a conclusion, I would like to Welcome you to the Nanostruc2012 and wish you a stimulating Conference and a wonderful time. On behalf of the scientific committee, Signature James Njuguna Conference Chair The PDF of this preface also contains committee listings and associates logos.

  5. Carbon Fiber Reinforced Carbon Composite Valve for an Internal Combustion Engine

    Science.gov (United States)

    Rivers, H. Kevin (Inventor); Ransone, Philip O. (Inventor); Northam, G. Burton (Inventor)

    1999-01-01

    A carbon fiber reinforced carbon composite valve for internal combustion engines and the like formed of continuous carbon fibers throughout the valve's stem and head is disclosed. The valve includes braided carbon fiber material over axially aligned unidirectional carbon fibers forming a valve stem; the braided and unidirectional carbon fibers being broomed out at one end of the valve stem forming the shape of the valve head; the valve-shaped structure being densified and rigidized with a matrix of carbon containing discontinuous carbon fibers: and the finished valve being treated to resist oxidation. Also disclosed is a carbon matrix plug containing continuous and discontinuous carbon fibers and forming a net-shape valve head acting as a mandrel over which the unidirectional and braided carbon fibers are formed according to textile processes. Also disclosed are various preform valves and processes for making finished and preform carbon fiber reinforced carbon composite valves.

  6. REMOTE DIAGNOSTICS OF TURNOUTS STATE ON TIMING AND SPECTRAL COMPOSITION IN CURRENT CURVE

    Directory of Open Access Journals (Sweden)

    S. Yu. Buryak

    2015-03-01

    Full Text Available Purpose. Development and implementation the points system diagnostics that would allow determining remotely the current state of turnout with all possible faults, gradual and sudden failures, damages, and in real time to report about their appearance. Methodology. State diagnostics on the values analysis of turnout main parameters is proposed to carry out with the help of a computer and analog-to-digital converter (ADC. Connecting measurements performance is advisable to produce to a shunt ammeter, installed in the working circuit of the point feed panel. ADC converts the analog signal of lost volts at the shunt into digital form and transmits it to a computer which stores the received data on its own recording medium for their further processing and storage. There is special software that is capable to reconnect signal and construct its temporal characteristic as well as decompose it on the spectral components. Using it one can analyze the obtained data, which allows diagnosing state of points upon change the nature, values and composition of the current curve. Findings. The computer diagnosis method was confirmed in practice for possible indications of problems that are associated with both the mechanical part of the turnout and the electrical part of it, while controlling parameters such as the amount of current normal transition, when working on frictions, the duration of the transition, properly adjusted headset and attachment points, the state of the motor. Originality. The use of computer technology in the diagnosis of the state of turnouts during their operation to monitor the current values of technical indicators, analysis and storage for all types of electric switches with different types of engines both DC and AC occurs through digitization and recording signal from measuring shunt of point feeder panel. Practical value. The proposed method enables timely, still in the early stages of defect parts, damages or failures of nodes

  7. Self-Supporting Nanoclay as Internal Scaffold Material for Direct Printing of Soft Hydrogel Composite Structures in Air.

    Science.gov (United States)

    Jin, Yifei; Liu, Chengcheng; Chai, Wenxuan; Compaan, Ashley; Huang, Yong

    2017-05-24

    Three dimensional (3D) bioprinting technology enables the freeform fabrication of complex constructs from various hydrogels and is receiving increasing attention in tissue engineering. The objective of this study is to develop a novel self-supporting direct hydrogel printing approach to extrude complex 3D hydrogel composite structures in air without the help of a support bath. Laponite, a member of the smectite mineral family, is investigated to serve as an internal scaffold material for the direct printing of hydrogel composite structures in air. In the proposed printing approach, due to its yield-stress property, Laponite nanoclay can be easily extruded through a nozzle as a liquid and self-supported after extrusion as a solid. Its unique crystal structure with positive and negative charges enables it to be mixed with many chemically and physically cross-linked hydrogels, which makes it an ideal internal scaffold material for the fabrication of various hydrogel structures. By mixing Laponite nanoclay with various hydrogel precursors, the hydrogel composites retain their self-supporting capacity and can be printed into 3D structures directly in air and retain their shapes before cross-linking. Then, the whole structures are solidified in situ by applying suitable cross-linking stimuli. The addition of Laponite nanoclay can effectively improve the mechanical and biological properties of hydrogel composites. Specifically, the addition of Laponite nanoclay results in a significant increase in the Young's modulus of each hydrogel-Laponite composite: 1.9-fold increase for the poly(ethylene glycol) diacrylate (PEGDA)-Laponite composite, 7.4-fold increase for the alginate-Laponite composite, and 3.3-fold increase for the gelatin-Laponite composite.

  8. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  9. Diagnostics of the Enterprise Export Potential

    Directory of Open Access Journals (Sweden)

    Skrynkovskyy Ruslan M.

    2016-11-01

    Full Text Available The aim of the article is to form and develop theoretical and methodological foundations for diagnostics of the enterprise export potential, which should be understood as a process of identification, analysis and assessment of the level of potential possibility and readiness of the enterprise to implement export activities taking into account the impact of interrelated internal variables (goals, technology, structure, tasks, educational and professional potential of the staff and factors of the enterprise external environment (customers, competitors, suppliers, intermediaries, contact audience, etc. in order to ensure a qualitatively new level of its development and formation of its prospects. It is determined that the key business indicators of the system for diagnostics of enterprise export potential are: the level of enterprises competitiveness in the international (global market; the level of competitiveness of enterprise products; the level of competitiveness of enterprise export products; the level of enterprise resource opportunities; the level of enterprise export performance. Prospects for further research in this direction are to develop a classification (specifically detailed list of objectives of the enterprise diagnostics by the level of detail (element, partial, complex, taking into account diagnostics of export potential of the enterprise as part of diagnostic objective.

  10. Internal friction in a new kind of metal matrix composites

    International Nuclear Information System (INIS)

    San Juan, J.; No, M.L.

    2006-01-01

    We have developed a new kind of metal matrix composites, based on powders of Cu-Al-Ni shape memory alloys (SMAs) surrounded by an indium matrix, specifically designed to exhibit high mechanical damping. The damping properties have been characterized by mechanical spectroscopy as a function of temperature between 150 and 400 K, frequency between 3 x 10 -3 and 3 Hz, and strain amplitude between 5 x 10 -6 and 10 -4 . The material exhibits, in some range of temperature, internal friction as high as 0.54. The extremely high damping is discussed in the light of the microstructure of the material, which has been characterized in parallel

  11. Analysis of neutron diffraction peak broadening caused by internal stresses in composite materials

    International Nuclear Information System (INIS)

    Todd, R.I.; Borsa, C.; Derby, B.

    1994-01-01

    Neutron diffraction is an essential tool in the study of internal stresses in composite materials. In most work only the peak shifts caused by the related elastic strains are considered, but other valuable information exists in the form of peak shape changes. The conditions under which the pure diffraction profile of the composite (i.e. the profile when all sources of broadening not caused by the residual stresses are removed) represents the probability distribution of the peak shifts corresponding to the strains are examined. It is shown that in these conditions, the pure diffraction profile has no attributes of particle size broadening (and vice versa), thereby providing a test for the validity of results interpreted in this way. The experimental derivation of measured strain distributions in Al 2 O 3 /SiCp composites using neutron diffraction is described. No apparent particle size broadening was detected, demonstrating the validity of the results, which also satisfied other tests for consistency

  12. A comparison of arthrography to clinical diagnostics for diagnosing meniscal lesions

    International Nuclear Information System (INIS)

    Neuer, H.

    1982-01-01

    A comparative investigation as to the exactness of clinical and arthrographical diagnostics was carried out on 176 patients who were clinically examined and operated on in the period of 1972-1980. Using solely clinical diagnostics, the total rate of exactness was 90,9%, the exactness regarding the internal meniscal lesion being significantly higher (94.2%) than that regarding external meniscal lesion (76.7%). Using solely arthrographic diagnostics, the total rate of exactness was 82%, the rate for internal meniscus being significantly lower (83.9%) than that obtained using clinical diagnostics. As for the external meniscus, the exactness of arthrography differs only slightly from clinical diagnostics with 74.7%. The most frequent sources of error in arthorgraphy were found to be lesions of the posterior horn at the internal meniscus. In cases of external meniscal lesions, especially when an internal meniscal lesion was existing at the same time, both examination methods failed in 5 cases. For routine diagnosing of meniscal lesions, arthrography is not necessary. An accurate clinical examination and anamnesis bring very good and exact results and should therefore be given absolute priority. (orig./MG) [de

  13. Physics R and D in support of ITER/BPX diagnostic development

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Boivin, R.; Costley, A.E.

    2003-01-01

    The development of diagnostics for a next step burning plasma experiment (BPX) is a major challenge. Within the International Tokamak Physics Activity (ITPA), one Topical Group (TG) specialises in diagnostics and aims to support the development and design of the needed systems. Several diagnostics issues have been identified as 'high priority' and form the focus of current work of the TG. The core of this paper is a presentation and discussion of recent progress in the field of these high priority research topics. Moreover, the status of the recently initiated International Diagnostic Database will be briefly described. (author)

  14. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  15. Diagnostic validity Polish language version of the questionnaire MINI-KID (Mini International Neuropsychiatry Interview for Children and Adolescent).

    Science.gov (United States)

    Adamowska, Sylwia; Sylwia, Adamowska; Adamowski, Tomasz; Tomasz, Adamowski; Frydecka, Dorota; Dorota, Frydecka; Kiejna, Andrzej; Andrzej, Kiejna

    2014-10-01

    Since over forty years structuralized interviews for clinical and epidemiological research in child and adolescent psychiatry are being developed that should increase validity and reliability of diagnoses according to classification systems (DSM and ICD). The aim of the study is to assess the validity of the Polish version of MINI-KID (Mini International Neuropsychiatric Interview for Children and Adolescents) in comparison to clinical diagnosis made by a specialist in the field of child and adolescent psychiatry. There were 140 patients included in the study (93 boys, 66.4%, mean age 11.8±3.0 and 47 girls 33.5%, mean age 14.0±2.9). All the patients were diagnosed by the specialist in the field of child and adolescent psychiatry according to ICD-10 criteria and by the independent interviewer with the Polish version of MINI-KID (version 2.0, 2001). There was higher agreement between clinical diagnoses and diagnoses based on MINI-KID interview with respect to eating disorders and externalizing disorders (κ 0.43-0.56) and lower in internalizing disorders (κ 0.13-0.45). In the clinical interview, there was smaller number of diagnostic categories (maximum 3 diagnoses per one patient) in comparison to MINI-KID (maximum 10 diagnoses per one patient), and the smaller percentage of patients with one diagnosis (65,7%) in comparison to MINI-KID interview (72%). Our study has shown satisfactory validity parameters of MINI-KID questionnaire, promoting its use for clinical and epidemiological settings. The Mini International Neuropsychiatry Interview for Children and Adolescent (MINI-KID) is the first structuralized diagnostic interview for assessing mental status in children and adolescents, which has been translated into Polish language. Our validation study demonstrated satisfactory psychometric properties of the questionnaire, enabling its use in clinical practice and in research projects. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Consensus statement of the international summit on intellectual disability and Dementia related to post-diagnostic support.

    Science.gov (United States)

    Dodd, Karen; Watchman, Karen; Janicki, Matthew P; Coppus, Antonia; Gaertner, Claudia; Fortea, Juan; Santos, Flavia H; Keller, Seth M; Strydom, Andre

    2017-09-07

    Post diagnostic support (PDS) has varied definitions within mainstream dementia services and different health and social care organizations, encompassing a range of supports that are offered to adults once diagnosed with dementia until death. An international summit on intellectual disability and dementia held in Glasgow, Scotland in 2016 identified how PDS applies to adults with an intellectual disability and dementia. The Summit proposed a model that encompassed seven focal areas: post-diagnostic counseling; psychological and medical surveillance; periodic reviews and adjustments to the dementia care plan; early identification of behaviour and psychological symptoms; reviews of care practices and supports for advanced dementia and end of life; supports to carers/ support staff; and evaluation of quality of life. It also explored current practices in providing PDS in intellectual disability services. The Summit concluded that although there is limited research evidence for pharmacological or non-pharmacological interventions for people with intellectual disability and dementia, viable resources and guidelines describe practical approaches drawn from clinical practice. Post diagnostic support is essential, and the model components in place for the general population, and proposed here for use within the intellectual disability field, need to be individualized and adapted to the person's needs as dementia progresses. Recommendations for future research include examining the prevalence and nature of behavioral and psychological symptoms (BPSD) in adults with an intellectual disability who develop dementia, the effectiveness of different non-pharmacological interventions, the interaction between pharmacological and non-pharmacological interventions, and the utility of different models of support.

  17. Recent diagnostic developments on LHD

    International Nuclear Information System (INIS)

    Sudo, S.; Nagayama, Y.; Peterson, B.J.

    2003-01-01

    Standard diagnostics for fundamental plasma parameters and for plasma physics are routinely utilized for daily operation and physics study in the large helical device (LHD) with high reliability. Diagnostics for steady state plasma are intensively developed, especially for T e , n e (YAG laser Thomson, CO 2 laser polarimeter), data acquisition in steady state, heat resistant probes. To clarify the plasma property of the helical structure, 2-D or 3-D diagnostics are intensively developed: Tangential cameras (Fast SX TV, Photon counting CCD, H α TV); Tomography (Tangential SX CCD, Bolometer); Imaging (Bolometer, ECE, Reflectometer). Divertor and edge physics are one of important key issues for steady state operation. Diagnostics for neutral flux (H α array, Zeeman spectroscopy) and n e (Fast scanning probe, Li beam probe, Pulsed radar reflectometer). In addition to these, advanced diagnostics are being intensively developed with national and international collaborations in LHD. (author)

  18. Radiation exposure in diagnostic medicine

    International Nuclear Information System (INIS)

    Haehnel, S.; Michalczak, H.; Reinoehl-Kompa, S.

    1995-01-01

    This volume includes the manuscripts of the papers read at the conference as well as a summary and assessment of its results. The scientific discussions were centred upon the following issues: - International surveys and comparisons of rdiation exposures in diagnostic radiology and nuclear medicine, frequency of the individual diagnostic procedures and age distribution of patients examined; - policies and regulations for the radiation protection of patients, charcteristic dosimetric values and practical usefulness of the effective dose concept during medical examinations; - assessments of the relative benefits and risks and measures to reduce the radiation exposure in the light of quality assurance aspects. The main objective of this conference not only was to evaluate the risks from diagnostic radiology and nuclear medicine but also to encourgage a critical analysis and adjustment of examination routines followed in everyday practice. Among the measures recommended were quality assurance, maintenace of international standards, development of guidelines, introduction of standard doses, improved training and professional education of personnel as well as surveys and analyses of certain examination procedures associated with substantial radiation exposure. (orig./MG) [de

  19. The european approach to quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    Benini, A.

    1997-01-01

    The european and increasingly the international organizations are emphasizing the importance of appropriate quality assurance programmes in diagnostic radiology. The European Directive (particularly the directive 84/466/EURATOM). the various publications of the International Commission for radiation protection (ICRP), related to protection of the patients and workers and the Basic Safety Standards of the International Atomic Energy Agency (IAEA) might be considered the landmarks of the new approach to the problems of dose reduction and quality in diagnostic radiology. In particular ICRP maintains a watching brief on all aspects related to radiation protection and makes recommendations concerning basic principles. Since ICRP 26 (1977), several ICRP publications have dealt with all the principal fields of diagnostic radiology. The IAEA has recently published the new Basic Safety Standards including guidance levels for the most common diagnostic investigations.Within the European countries the European Union and the European legislation have strong influence of the implementation of radiation protection and Q A at a national level. This has led to a substantial effort in the european countries to establish national standards and basic quality requirements. (author)

  20. Application of ceramic short fiber reinforced Al alloy matrix composite on piston for internal combustion engines

    Directory of Open Access Journals (Sweden)

    Wu Shenqing

    2010-11-01

    Full Text Available The preparation and properties of ceramic short fiber reinforced Al-Si alloy matrix composite and it’s application on the piston for internal combustion engines are presented. Alumina or aluminosilicate fibers reinforced Al-Si alloy matrix composite has more excellent synthetical properties at elevated temperature than the matrix alloys. A partially reinforced Al-Si alloy matrix composite piston produced by squeeze casting technique has a firm interface between reinforced and unreinforced areas, low reject rate and good technical tolerance. As a new kind of piston material, it has been used for mass production of about 400,000 pieces of automobile engines piston. China has become one of a few countries in which aluminum alloy matrix composite materials have been used in automobile industry and attained industrialization.

  1. The diagnostic status of first-rank symptoms

    DEFF Research Database (Denmark)

    Nordgaard, Julie; Arnfred, Sidse Marie; Handest, P.

    2008-01-01

    In the International Statistical Classification of Diseases, Tenth Revision(ICD-10) and Diagnostic and Statistical Manual of Mental Disorder, Third and Fourth Edition(DSM-III-IV), the presence of one of Schneider "first-rank symptoms" (FRS) is symptomatically sufficient for the schizophrenia...... diagnosis. Yet, it has been claimed that FRS may also be found in the nonschizophrenic conditions, and therefore, they are not specific or diagnostic for schizophrenia. This review was made to clarify the issue of diagnostic specificity....

  2. International society of sports nutrition position stand: diets and body composition.

    Science.gov (United States)

    Aragon, Alan A; Schoenfeld, Brad J; Wildman, Robert; Kleiner, Susan; VanDusseldorp, Trisha; Taylor, Lem; Earnest, Conrad P; Arciero, Paul J; Wilborn, Colin; Kalman, Douglas S; Stout, Jeffrey R; Willoughby, Darryn S; Campbell, Bill; Arent, Shawn M; Bannock, Laurent; Smith-Ryan, Abbie E; Antonio, Jose

    2017-01-01

    Position Statement: The International Society of Sports Nutrition (ISSN) bases the following position stand on a critical analysis of the literature regarding the effects of diet types (macronutrient composition; eating styles) and their influence on body composition. The ISSN has concluded the following. 1) There is a multitude of diet types and eating styles, whereby numerous subtypes fall under each major dietary archetype. 2) All body composition assessment methods have strengths and limitations. 3) Diets primarily focused on fat loss are driven by a sustained caloric deficit. The higher the baseline body fat level, the more aggressively the caloric deficit may be imposed. Slower rates of weight loss can better preserve lean mass (LM) in leaner subjects. 4) Diets focused primarily on accruing LM are driven by a sustained caloric surplus to facilitate anabolic processes and support increasing resistance-training demands. The composition and magnitude of the surplus, as well as training status of the subjects can influence the nature of the gains. 5) A wide range of dietary approaches (low-fat to low-carbohydrate/ketogenic, and all points between) can be similarly effective for improving body composition. 6) Increasing dietary protein to levels significantly beyond current recommendations for athletic populations may result in improved body composition. Higher protein intakes (2.3-3.1 g/kg FFM) may be required to maximize muscle retention in lean, resistance-trained subjects under hypocaloric conditions. Emerging research on very high protein intakes (>3 g/kg) has demonstrated that the known thermic, satiating, and LM-preserving effects of dietary protein might be amplified in resistance-training subjects. 7) The collective body of intermittent caloric restriction research demonstrates no significant advantage over daily caloric restriction for improving body composition. 8) The long-term success of a diet depends upon compliance and suppression or

  3. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  4. Smoke composition and predicting relationships for international commercial cigarettes smoked with three machine-smoking conditions.

    Science.gov (United States)

    Counts, M E; Morton, M J; Laffoon, S W; Cox, R H; Lipowicz, P J

    2005-04-01

    The study objectives were to determine the effects of smoking machine puffing parameters on mainstream smoke composition and to express those effects as predicting relationships. Forty-eight commercial Philip Morris USA and Philip Morris International cigarettes from international markets and the 1R4F reference cigarette were machine-smoked using smoking conditions defined by the International Organization of Standardization (ISO), the Massachusetts Department of Public Health (MDPH), and Health Canada (HC). Cigarette tobacco fillers were analyzed for nitrate, nicotine, tobacco-specific nitrosamines (TSNA), and ammonia. Mainstream yields for tar and 44 individual smoke constituents and "smoke pH" were determined. Cigarette constituent yields typically increased in the order ISOrelationships were developed between ISO tar and ISO, MDPH, and HC constituent yields and between MDPH tar and HC tar and respective smoking condition yields. MDPH and HC constituent yields could be predicted with similar reliability using ISO tar or the corresponding smoking-condition tar. The reliability of the relationships varied from strong to weak, depending on particular constituents. Weak predicting relationships for nitrogen oxides and TSNA's, for example, were improved with inclusion of tobacco filler composition factors. "Smoke pH" was similar for all cigarettes at any one smoking condition, and overall marginally lower at HC conditions than at ISO or MDPH conditions.

  5. Litigations in diagnostic radiology

    International Nuclear Information System (INIS)

    Patil, Ranjit

    2014-01-01

    There are various regulatory bodies at the international and national level, which lay down norms for radiation protection. These are the International Commission for Radiation Protection (ICRP) the National Commission for Radiation Protection (NCRP) in America, and the Atomic Energy Regulatory Board (AERB) in India. These bodies recommend norms on various radiation issues. Radiography and radiology are two key tools for diagnosing and treating diseases. Recently there are concerns about the effect of ionizing radiation on man and the frequent use of diagnostic radiographs. The professionals are expected to conduct their actions according to guidelines which reflect new information and changing technology in diagnostic radiography. Failure to do so may have severe legal consequences. Patient protection is a matter of normal course but knowledge and awareness of the legal issues is important to avoid legal hassles. Implications of the radiation protection guidelines are discussed. (author)

  6. Nordic working group for medical x-ray diagnostics: Diagnostic reference levels within xray diagnostics - experiences in the Nordic countries

    International Nuclear Information System (INIS)

    Leitz, W.; Groen, P.; Servomaa, A.; Einarsson, G.; Olerud, H.

    2003-01-01

    Medical x-ray diagnostics is one of the few applications of ionising radiation where people are irradiated on purpose. The strategy for radiation protection is also different compared to that in other areas that have the zero-alternative as its ultimate goal, meaning that no human beings at all are exposed in these practices. The focus in x-ray diagnostics concerning radiation protection is justification and optimisation. Optimisation implies that the examination is performed in such a way that the radiation dose is as small as possible without jeopardising the diagnostic security. X- ray diagnostics is a complex method where many technical parameters and methodology factors together are interacting in the determination of radiation dose and image quality. The optimisation process is not a simple and uncomplicated procedure, this difficulty is reflected in many international and national surveys showing a large spread of patient doses for one and the same type of examination. The concept diagnostic reference levels (DRL) has been introduced as a tool for reducing this wide distribution that is obviously indicating a lack of optimisation, and for cutting the highest radiation doses. In this presentation the concept for DRL and the experience gained in the Nordic countries with DRL are described. (orig.)

  7. Revisiting Classification of Eating Disorders-toward Diagnostic and Statistical Manual of Mental Disorders-5 and International Statistical Classification of Diseases and Related Health Problems-11.

    Science.gov (United States)

    Goyal, Shrigopal; Balhara, Yatan Pal Singh; Khandelwal, S K

    2012-07-01

    Two of the most commonly used nosological systems- International Statistical Classification of Diseases and Related Health Problems (ICD)-10 and Diagnostic and Statistical Manual of Mental Disorders (DSM)-IV are under revision. This process has generated a lot of interesting debates with regards to future of the current diagnostic categories. In fact, the status of categorical approach in the upcoming versions of ICD and DSM is also being debated. The current article focuses on the debate with regards to the eating disorders. The existing classification of eating disorders has been criticized for its limitations. A host of new diagnostic categories have been recommended for inclusion in the upcoming revisions. Also the structure of the existing categories has also been put under scrutiny.

  8. Nanodevices in diagnostics

    Science.gov (United States)

    Hu, Ye; Fine, Daniel H.; Tasciotti, Ennio; Bouamrani, Ali; Ferrari, Mauro

    2010-01-01

    The real-time, personalized and highly sensitive early-stage diagnosis of disease remains an important challenge in modern medicine. With the ability to interact with matter at the nanoscale, the development of nanotechnology architectures and materials could potentially extend subcellular and molecular detection beyond the limits of conventional diagnostic modalities. At the very least, nanotechnology should be able to dramatically accelerate biomarker discovery, as well as facilitate disease monitoring, especially of maladies presenting a high degree of molecular and compositional heterogeneity. This article gives an overview of several of the most promising nanodevices and nanomaterials along with their applications in clinical practice. Significant work to adapt nanoscale materials and devices to clinical applications involving large interdisciplinary collaborations is already underway with the potential for nanotechnology to become an important enabling diagnostic technology. PMID:20229595

  9. Systematic internal transcribed spacer sequence analysis for identification of clinical mold isolates in diagnostic mycology: a 5-year study.

    Science.gov (United States)

    Ciardo, Diana E; Lucke, Katja; Imhof, Alex; Bloemberg, Guido V; Böttger, Erik C

    2010-08-01

    The implementation of internal transcribed spacer (ITS) sequencing for routine identification of molds in the diagnostic mycology laboratory was analyzed in a 5-year study. All mold isolates (n = 6,900) recovered in our laboratory from 2005 to 2009 were included in this study. According to a defined work flow, which in addition to troublesome phenotypic identification takes clinical relevance into account, 233 isolates were subjected to ITS sequence analysis. Sequencing resulted in successful identification for 78.6% of the analyzed isolates (57.1% at species level, 21.5% at genus level). In comparison, extended in-depth phenotypic characterization of the isolates subjected to sequencing achieved taxonomic assignment for 47.6% of these, with a mere 13.3% at species level. Optimization of DNA extraction further improved the efficacy of molecular identification. This study is the first of its kind to testify to the systematic implementation of sequence-based identification procedures in the routine workup of mold isolates in the diagnostic mycology laboratory.

  10. Sixth meeting of the ITPA Topical Group on Diagnostics

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Costley, A.E.

    2004-01-01

    The Sixth Meeting of the International Tokamak Physics Activities (ITPA) Topical Group (TG) on Diagnostics was held at JAERI, Naka from 19-21 February 2004. This meeting was combined with a Progress Meeting on ITER/BPX (burning plasma experiment) relevant diagnostic developments on-going in Japan. For the first time, ITPA members from China, as well as observers from South Korea, attended. In addition, an associated sub-meeting was held at General Atomics, San Diego, 23-24 April, immediately after the 15th Topical Conference on High Temperature Plasma Diagnostics. At the sub-meeting a special one-day session was devoted to issues related to beam-aided spectroscopy. In total more than 50 participants attended the meetings and all ITER partners were represented. The key topics reviewed and discussed at the TG meeting were: (i) the overall status of diagnostics developments for ITER, (ii) the progress in the research on the designated high priority topics, (iii) the progress with some key ITER/BPX-relevant diagnostic developments ongoing in the ITPA participant laboratories, (iv) the progress and plans for the work of the specialist working groups, (v) the status and plans for the International Diagnostic Database

  11. Diagnostics of internal inductance in HT-7

    International Nuclear Information System (INIS)

    Zeng Li; Wan Baonian; Qian Jinping; Fan Hengyu

    2001-01-01

    Two arrays of Mirnov coils and a pair of concentric loops have been installed to superconducting tokamak HT-7. Software compensation and digital Fourier series expansion are the two techniques that have been applied successfully in measuring diamagnetic flux of concentric loops and internal inductance. The internal inductance of plasma l i , poloidal beta β p , Grad Shafranov parameter Λ, plasma minor radius α p and the center of the outermost magnetic flux surface Δ g are determined

  12. Investigation of the design of a metal-lined fully wrapped composite vessel under high internal pressure

    Science.gov (United States)

    Kalaycıoğlu, Barış; Husnu Dirikolu, M.

    2010-09-01

    In this study, a Type III composite pressure vessel (ISO 11439:2000) loaded with high internal pressure is investigated in terms of the effect of the orientation of the element coordinate system while simulating the continuous variation of the fibre angle, the effect of symmetric and non-symmetric composite wall stacking sequences, and lastly, a stacking sequence evaluation for reducing the cylindrical section-end cap transition region stress concentration. The research was performed using an Ansys® model with 2.9 l volume, 6061 T6 aluminium liner/Kevlar® 49-Epoxy vessel material, and a service internal pressure loading of 22 MPa. The results show that symmetric stacking sequences give higher burst pressures by up to 15%. Stacking sequence evaluations provided a further 7% pressure-carrying capacity as well as reduced stress concentration in the transition region. Finally, the Type III vessel under consideration provides a 45% lighter construction as compared with an all metal (Type I) vessel.

  13. Nuclear power plant diagnostic system

    International Nuclear Information System (INIS)

    Prokop, K.; Volavy, J.

    1982-01-01

    Basic information is presented on diagnostic systems used at nuclear power plants with PWR reactors. They include systems used at the Novovoronezh nuclear power plant in the USSR, at the Nord power plant in the GDR, the system developed at the Hungarian VEIKI institute, the system used at the V-1 nuclear power plant at Jaslovske Bohunice in Czechoslovakia and systems of the Rockwell International company used in US nuclear power plants. These diagnostic systems are basically founded on monitoring vibrations and noise, loose parts, pressure pulsations, neutron noise, coolant leaks and acoustic emissions. The Rockwell International system represents a complex unit whose advantage is the on-line evaluation of signals which gives certain instructions for the given situation directly to the operator. The other described systems process signals using similar methods. Digitized signals only serve off-line computer analyses. (Z.M.)

  14. Carbon Fiber Reinforced Carbon Composites Rotary Valves for Internal Combustion Engines

    Science.gov (United States)

    Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    1999-01-01

    Carbon fiber reinforced carbon composite rotary, sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or warp-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties, do not present the sealing and lubrication problems that have prevented rotary, sleeve, and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  15. Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras.

    Science.gov (United States)

    de Paula Silveira, Alessandra C; Chaves, Sacha B; Hilgert, Leandro A; Ribeiro, Ana Paula D

    2017-03-01

    The precision of fit of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) complete crowns is affected by digital impression and restorative material. The purpose of this in vitro study was to evaluate by microcomputed tomography (μCT) the marginal and internal adaptation of composite resin and ceramic complete crowns fabricated with 2 different intraoral cameras and 2 restorative materials. Ten extracted human third molars received crown preparations. For each prepared molar, 2 digital impressions were made with different intraoral cameras of the CEREC system, Bluecam and Omnicam. Four groups were formed: LB (Lava Ultimate+Bluecam), EB (Emax+Bluecam), LO (Lava Ultimate+Omnicam), and EO (Emax+Omnicam). Before measuring the precision of fit, all crowns were stabilized with a silicone material. Each unit (crown + prepared tooth) was imaged with μCT, and marginal and internal discrepancies were analyzed. For the 2D analysis, 120 measurements were made of each crown for marginal adaptation, 20 for marginal discrepancy (MD), and 20 for absolute marginal discrepancy (AMD); and for internal adaptation, 40 for axial space (AS) and 40 for occlusal space (OS). After reconstructing the 3D images, the average internal space (AIS) was calculated by dividing the total volume of the internal space by the contact surface. Data were analyzed with 2-way ANOVA and quantile regression. Regarding marginal adaptation, no significant differences were observed among groups. For internal adaptation measured in the 2D evaluation, a significant difference was observed between LO and EO for the AS variable (Mann-Whitney test; POmnicam, and composite resin crowns showed less discrepancy than did ceramic crowns. The marginal adaptations assessed in all groups showed values within the clinically accepted range. Moreover, the composite resin blocks associated with the Bluecam intraoral camera demonstrated the best results for AIS compared with those of the other groups

  16. Biomimetic mineral-organic composite scaffolds with controlled internal architecture.

    Science.gov (United States)

    Manjubala, I; Woesz, Alexander; Pilz, Christine; Rumpler, Monika; Fratzl-Zelman, Nadja; Roschger, Paul; Stampfl, Juergen; Fratzl, Peter

    2005-12-01

    Bone and cartilage generation by three-dimensional scaffolds is one of the promising techniques in tissue engineering. One approach is to generate histologically and functionally normal tissue by delivering healthy cells in biocompatible scaffolds. These scaffolds provide the necessary support for cells to proliferate and maintain their differentiated function, and their architecture defines the ultimate shape. Rapid prototyping (RP) is a technology by which a complex 3-dimensional (3D) structure can be produced indirectly from computer aided design (CAD). The present study aims at developing a 3D organic-inorganic composite scaffold with defined internal architecture by a RP method utilizing a 3D printer to produce wax molds. The composite scaffolds consisting of chitosan and hydroxyapatite were prepared using soluble wax molds. The behaviour and response of MC3T3-E1 pre-osteoblast cells on the scaffolds was studied. During a culture period of two and three weeks, cell proliferation and in-growth were observed by phase contrast light microscopy, histological staining and electron microscopy. The Giemsa and Gömöri staining of the cells cultured on scaffolds showed that the cells proliferated not only on the surface, but also filled the micro pores of the scaffolds and produced extracellular matrix within the pores. The electron micrographs showed that the cells covering the surface of the struts were flattened and grew from the periphery into the middle region of the pores.

  17. Body Composition and Survival in Dialysis Patients: Results from an International Cohort Study

    Science.gov (United States)

    Usvyat, Len A.; Kotanko, Peter; Bayh, Inga; Canaud, Bernard; Etter, Michael; Gatti, Emanuele; Grassmann, Aileen; Wang, Yuedong; Marelli, Cristina; Scatizzi, Laura; Stopper, Andrea; van der Sande, Frank M.; Kooman, Jeroen

    2015-01-01

    Background and objectives High body mass index appears protective in hemodialysis patients, but uncertainty prevails regarding which components of body composition, fat or lean body mass, are primarily associated with survival. Design, setting, participants, & measurements Data between April 2006 and December 2012 were extracted from the Fresenius Medical Care Europe subset of the international MONitoring Dialysis Outcomes initiative. Fresenius Medical Care Europe archives a unique repository of predialysis body composition measurements determined by multifrequency bioimpedance (BCM Body Composition Monitor). The BCM Body Composition Monitor reports lean tissue indices (LTIs) and fat tissue indices (FTIs), which are the respective tissue masses normalized to height squared, relative to an age- and sex-matched healthy population. The relationship between LTI and FTI and all-cause mortality was studied by Kaplan–Meier analysis, multivariate Cox regression, and smoothing spline ANOVA logistic regression. Results In 37,345 hemodialysis patients, median (25th–75th percentile) LTI and FTI were 12.2 (10.3–14.5) and 9.8 (6.6–12.4) kg/m2, respectively. Median (25th–75th percentile) follow-up time was 266 (132–379) days; 3458 (9.2%) patients died during follow-up. Mortality was lowest with both LTI and FTI in the 10th–90th percentile (reference group) and significantly higher at the lower LTI and FTI extreme (hazard ratio [HR], 3.37; 95% confidence interval [95% CI], 2.94 to 3.87; P<0.001). Survival was best with LTI between 15 and 20 kg/m2 and FTI between 4 and 15 kg/m2 (probability of death during follow-up: <5%). When taking the relation between both compartments into account, the interaction was significant (P=0.01). Higher FTI appeared protective in patients with low LTI (HR, 3.37; 95% CI, 2.94 to 3.87; P<0.001 at low LTI–low FTI, decreasing to HR, 1.79; 95% CI, 1.47 to 2.17; P<0.001 at low LTI–high FTI). Conclusions This large international study

  18. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 - 2016 Ebola outbreak in West Africa.

    Science.gov (United States)

    Ellerbrok, Heinz; Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-05-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied.

  19. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 - 2016 Ebola outbreak in West Africa.

    Directory of Open Access Journals (Sweden)

    Heinz Ellerbrok

    2017-05-01

    Full Text Available During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied.

  20. Electromagnetic diagnostic system for the Keda Torus eXperiment

    Science.gov (United States)

    Tu, Cui; Liu, Adi; Li, Zichao; Tan, Mingsheng; Luo, Bing; You, Wei; Li, Chenguang; Bai, Wei; Fu, Chenshuo; Huang, Fangcheng; Xiao, Bingjia; Shen, Biao; Shi, Tonghui; Chen, Dalong; Mao, Wenzhe; Li, Hong; Xie, Jinglin; Lan, Tao; Ding, Weixing; Xiao, Chijin; Liu, Wandong

    2017-09-01

    A system for electromagnetic measurements was designed and installed on the Keda Torus eXperiment (KTX) reversed field pinch device last year. Although the unique double-C structure of the KTX, which allows the machine to be opened easily without disassembling the poloidal field windings, makes the convenient replacement and modification of the internal inductive coils possible, it can present difficulties in the design of flux coils and magnetic probes at the two vertical gaps. Moreover, the KTX has a composite shell consisting of a 6 mm stainless steel vacuum chamber and a 1.5 mm copper shell, which results in limited space for the installation of saddle sensors. Therefore, the double-C structure and composite shell should be considered, especially during the design and installation of the electromagnetic diagnostic system (EDS). The inner surface of the vacuum vessel includes two types of probes. One type is for the measurement of the global plasma parameters, and the other type is for studying the local behavior of the plasma and operating the new saddle coils. In addition, the probes on the outer surface of the composite shell are used for measurements of eddy currents. Finally, saddle sensors for radial field measurements for feedback control were installed between the conducting shell and the vacuum vessel. The entire system includes approximately 1100 magnetic probes, 14 flux coils, 4 ×26 ×2 saddle sensors, and 16 Rogowski coils. Considering the large number of probes and limited space available in the vacuum vessel, the miniaturization of the probes and optimization of the probe distribution are necessary. In addition, accurate calibration and careful mounting of the probes are also required. The frequency response of the designed magnetic probes is up to 200 kHz, and the resolution is 1 G. The EDS, being spherical and of high precision, is one of the most basic and effective diagnostic tools of the KTX and meets the demands imposed by requirements on

  1. Cross-cultural and comparative epidemiology of insomnia: the Diagnostic and statistical manual (DSM), International classification of diseases (ICD) and International classification of sleep disorders (ICSD).

    Science.gov (United States)

    Chung, Ka-Fai; Yeung, Wing-Fai; Ho, Fiona Yan-Yee; Yung, Kam-Ping; Yu, Yee-Man; Kwok, Chi-Wa

    2015-04-01

    To compare the prevalence of insomnia according to symptoms, quantitative criteria, and Diagnostic and Statistical Manual of Mental Disorders, 4th and 5th Edition (DSM-IV and DSM-5), International Classification of Diseases, 10th Revision (ICD-10), and International Classification of Sleep Disorders, 2nd Edition (ICSD-2), and to compare the prevalence of insomnia disorder between Hong Kong and the United States by adopting a similar methodology used by the America Insomnia Survey (AIS). Population-based epidemiological survey respondents (n = 2011) completed the Brief Insomnia Questionnaire (BIQ), a validated scale generating DSM-IV, DSM-5, ICD-10, and ICSD-2 insomnia disorder. The weighted prevalence of difficulty falling asleep, difficulty staying asleep, waking up too early, and non-restorative sleep that occurred ≥3 days per week was 14.0%, 28.3%, 32.1%, and 39.9%, respectively. When quantitative criteria were included, the prevalence dropped the most from 39.9% to 8.4% for non-restorative sleep, and the least from 14.0% to 12.9% for difficulty falling asleep. The weighted prevalence of DSM-IV, ICD-10, ICSD-2, and any of the three insomnia disorders was 22.1%, 4.7%, 15.1%, and 22.1%, respectively; for DSM-5 insomnia disorder, it was 10.8%. Compared with 22.1%, 3.9%, and 14.7% for DSM-IV, ICD-10, and ICSD-2 in the AIS, cross-cultural difference in the prevalence of insomnia disorder is less than what is expected. The prevalence is reduced by half from DSM-IV to DSM-5. ICD-10 insomnia disorder has the lowest prevalence, perhaps because excessive concern and preoccupation, one of its diagnostic criteria, is not always present in people with insomnia. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    Science.gov (United States)

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  3. PREFACE: 25th International Congress on Condition Monitoring and Diagnostic Engineering (COMADEM 2012)

    Science.gov (United States)

    Ball, Andrew; Mishra, Rakesh; Gu, Fengshou; Rao, Raj B. K. N.

    2012-05-01

    The proactive multidisciplinary conceptual philosophy of Condition Monitoring and Diagnostic Engineering Management (COMADEM) was conceived and has been nurtured, developed and sustained since 1988. Since then, it is gratifying to note that the condition monitoring, diagnostic and prognostic community worldwide (representing industrialists, academics, research and development organizations, professional/private establishments and many hardware/software vending organizations) has warmly welcomed and supported this venture. As is evidenced, many have reaped (and are reaping) the benefits of COMADEM interdiscipline through continuous knowledge discovery, generation and dissemination. We are now proud to celebrate the 25th Annual Event (Silver Jubilee) in Huddersfield, the most beautiful part of the United Kingdom. The theme of this Congress is 'Sustained Prosperity through Proactive Monitoring, Diagnosis, Prognosis and Management'. This proceedings is enriched by contributions from many keynote experts representing many industry and academic establishments worldwide. Authors from more than 30 different countries have pooled their rich multidisciplinary up-to-date knowledge, in order to share their invaluable experience with the COMADEM community. In this proceedings, the readers will find more than 120 refereed papers encompassing a number of topical areas of interest relating to the theme of the congress. The proceedings of COMADEM 2012 will appear in the Open Access Journal of Physics: Conference Series (JPCS), which is part of the IOP Conference Series. All papers published in the IOP Conference Series are fully citable and upon publication will be free to download. We would like to express our deep gratitude to all the keynote speakers, authors, referees, exhibitors, Technical Co-Sponsoring Organizations, Gold Sponsors, IOP Publishers, COMADEM 2012 organizing committee members, delegates and many others on whom the success of this prestigious event depends

  4. Patterns of anaphylaxis after diagnostic workup

    DEFF Research Database (Denmark)

    Oropeza, Athamaica Ruiz; Bindslev-Jensen, Carsten; Broesby-Olsen, Sigurd

    2017-01-01

    BACKGROUND: Most published studies on anaphylaxis are retrospective or register based. Data on subsequent diagnostic work-up are sparse. We aimed to characterize patients seen with suspected anaphylaxis at the emergency care setting (ECS), after subsequent diagnostic work-up at our Allergy Center...... (AC). METHODS: Prospective study including patients from the ECS, Odense University Hospital, during May 2013-April 2014. Possible anaphylaxis cases were daily identified based on a broad search profile including history and symptoms in patient records, diagnostic codes and pharmacological treatments....... At the AC, all patients were evaluated according to international guidelines. RESULTS: Among 226 patients with suspected anaphylaxis, the diagnosis was confirmed in 124 (54.9%) after diagnostic work-up; 118 of the 124 fulfilled WAO/EAACI criteria of anaphylaxis at the ECS, while 6 were found among 46...

  5. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  6. Thyroid Ultrasound: Change of Inter-observer Variability and Diagnostic Performance after Training

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kim, Eun Kyung; Kwak, Jin Young; Park, Jeong Seon

    2011-01-01

    To investigate and compare inter-observer variability and diagnostic performance of thyroid ultrasound (US) between a faculty member and observing residents. From October 2007 to June 2009, 18 residents underwent training in thyroid US section. Group 1 included 8 residents that were trained for the first time and group 2 included 10 residents that were trained for the second time. US features of nodules were recorded according to the composition, echogenicity, margin, calcifications, shape, and final assessment by a faculty member and residents, respectively. Following a discussion, a faculty member performed fine needle aspiration. Then, the inter-observer variability and diagnostic performance between a faculty member and residents were investigated and compared for US. In group 1, agreement for composition in resident 1, calcification for residents 5 and 6, and shape for resident 4 were slight, moderate, moderate, and moderate, respectively. In group 2, agreement for composition in residents 1 and 10 were moderate. Substantial or greater agreement was observed more frequently in group 2 than 1. The diagnostic performances for both the faculty and residents were high and not statistically different. Agreement for US features between a faculty and residents as well as diagnostic performance were high. Moreover, diagnostic performance of residents that underwent training a second time of training was higher than residents that underwent training only once

  7. Main areas for the sociological support of organizational risks diagnostics and prevention in the internal affairs bodies

    Directory of Open Access Journals (Sweden)

    T H Dzhanteev

    2016-12-01

    Full Text Available The article considers the use of theoretical and applied sociological studies to identify and prevent negative consequences of the organizational risks in the internal affairs bodies, such as: insufficient quality of the organizational structure; failures in the design of organizational structures; poor coordination and regulation; inconsistency of resources provision; mistakes in the selection and placement of personnel; shortcomings in the organization of interaction with the public; incorrect definition of the needs of citizens in the field of law enforcement; poor quality of law enforcement services; inadequate training of personnel for the interaction with citizens. The author describes the role of the sociological support in the diagnostics of organizational risks, and pays particular attention to the factors contributing to the occurrence of undesirable situations and to the cause-and-effect relationships between various events associated with the risks. The article emphasizes the exceptional importance of forecasting negative consequences of risk situations and developing measures to minimize negative effects of organizational risks in law enforcement in general and in the internal affairs bodies in particular.

  8. Perception Of Trader Towards International Trade: A Diagnostic Study

    Directory of Open Access Journals (Sweden)

    Muzaffar Asad

    2010-12-01

    Full Text Available In this article the authors have identified the significant factors that influence international trade in the light of traders. Foreign exchange transaction may prove to be helpful in managing currency risk which is associated with import and export of goods. The significance of multi-national firms over international trade has been discussed along with the impact of balance of payment over international trade and the measures taken by the government to create a balance in balance of payment and balance of trade. The considerations of countries while determining exchange rates have been elaborated in this paper. The numerous factors that affect decision making for International Traders and the rectifications are also discussed in this paper. The paper also discusses how various aspects induce an industry to change its course or completely shut down and how to deal with these lingering threats. On the basis of literature reviewed the variables that have been selected that may influence international trade include; trade quotas, brand name, WTO, NAFTA, SAFTA, ASIAN, GATT, e-commerce, international payment systems, product specialization, home industry, foreign reserves, government regulations, international market, dumping duties, trade policies, social crises, economic crises, balance of payments, change in value, and supply than demand. A questionnaire will be developed on the basis of above-mentioned variables. The respondents of questionnaire will be the traders in the international market, importers and exporters. The data will then be handled by the use of SPSS. Regression analysis will be conducted to identify the significant variables that have major impact on international trade. At the end the recommendations will be mentioned for getting maximum benefit from international trade.

  9. 7th international symposium on internal combustion diagnostics. Proceedings; 7. Internationales Symposium fuer Verbrennungsdiagnostik. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    At one time combustion pressure indicating was the ''trigger'' for this symposium, and today it still serves as the basis for continued investigation of combustion phenomena. It now finds application throughout the development process, as more sophisticated analysis of conventional signals is possible. Understanding of localized combustion phenomena is substantially simplified by means of optical diagnostic methods, the application of which has reached a certain level of standardization. The presentations will cover specific topics including fuel spray analysis, ignition events and information about gas mixtures. The comparison and combination of results from measurement and simulation shed light on the complex processes in the combustion chamber. What's more, the linkage of two complementary methods offers substantial cost savings through reductions in test hardware and shorter development times. Focused application of all of the available tools allows us better to understand combustion processes, recognize the influential parameters and derive control algorithms. The latter are subsequently to be found in engines that fulfill both regulatory requirements and customer expectations. So it is that the symposium captures the current state of the art in combustion diagnostics through a combination of indicating, optical diagnostics and simulation, and offers both the methodology expert and the engine developer the ideal platform for discussion of today's issues - and to form their own opinions on them. Anyone wanting to keep up to date in this continuously developing and ever more complex area of activity certainly can't afford to miss our symposium. (orig.)

  10. Quality control for diagnostic oral microbiology laboratories in European countries

    NARCIS (Netherlands)

    Rautemaa-Richardson, R.; van der Reijden, W.A.; Dahlen, G.; Smith, A.J.

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB)

  11. Quality systems in veterinary diagnostics laboratories.

    Science.gov (United States)

    de Branco, Freitas Maia L M

    2007-01-01

    Quality assurance of services provided by veterinary diagnostics laboratories is a fundamental element promoted by international animal health organizations to establish trust, confidence and transparency needed for the trade of animals and their products at domestic and international levels. It requires, among other things, trained personnel, consistent and rigorous methodology, choice of suitable methods as well as appropriate calibration and traceability procedures. An important part of laboratory quality management is addressed by ISO/IEC 17025, which aims to facilitate cooperation among laboratories and their associated parties by assuring the generation of credible and consistent information derived from analytical results. Currently, according to OIE recommendation, veterinary diagnostics laboratories are only subject to voluntary compliance with standard ISO/IEC 17025; however, it is proposed here that OIE reference laboratories and collaboration centres strongly consider its adoption.

  12. Announcement of the Diagnostics 2016 Junior Scientists Travel Award

    OpenAIRE

    2016-01-01

    With the goal of recognizing outstanding contributions to the field of medical diagnostics by early-career investigators, including assistant professors, postdoctoral students and PhD students, and assisting them in attending international conferences in 2016, early this year Diagnostics accepted nominations for the Junior Scientists Travel Award 2016.

  13. Diagnostic accuracy of imaging modalities for internal derangements of temporomandibular joint

    International Nuclear Information System (INIS)

    Kobayashi, Kaoru; Igarashi, Chinami; Yuasa, Masao; Imanaka, Masahiro; Kondoh, Toshirou

    1998-01-01

    The purpose of this study was to evaluate and review the diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of imaging diagnosis for temporomandibular disorders. The role of diagnostic imaging is to detect and document specific anatomic abnormalities associated with the signs and symptoms in the temporomandibular joint. Magnetic resonance imaging (MR imaging) can accurately depict disc displacement and disc deformity. MR imaging is our first choice among the various imaging modalities for the patients with clinical signs and symptoms. However, it has been shown that intra-capsular adhesions and perforations of the disc and retrodiscal tissue are sometimes not detected by MR imaging. To improve the diagnostic technique for adhesions and perforations, double-contrast arthrotomography with fluoroscopy should be employed. The irregular surface of the eminences and the glenoid fossae shown by MR imaging and tomography are correlated with subchondral bone exposure by arthroscopy. Erosion of the condyles detected by MR imaging, tomography and rotational panoramic radiography is correlated with subchondral bone exposure detected by arthroscopy. (author). 69 refs

  14. Real time PV manufacturing diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Kochergin, Vladimir [MicroXact Inc., Blacksburg, VA (United States); Crawford, Michael A. [MicroXact Inc., Blacksburg, VA (United States)

    2015-09-01

    The main obstacle Photovoltaic (PV) industry is facing at present is the higher cost of PV energy compared to that of fossil energy. While solar cell efficiencies continue to make incremental gains these improvements are so far insufficient to drive PV costs down to match that of fossil energy. Improved in-line diagnostics however, has the potential to significantly increase the productivity and reduce cost by improving the yield of the process. On this Phase I/Phase II SBIR project MicroXact developed and demonstrated at CIGS pilot manufacturing line a high-throughput in-line PV manufacturing diagnostic system, which was verified to provide fast and accurate data on the spatial uniformity of thickness, an composition of the thin films comprising the solar cell as the solar cell is processed reel-to-reel. In Phase II project MicroXact developed a stand-alone system prototype and demonstrated the following technical characteristics: 1) ability of real time defect/composition inconsistency detection over 60cm wide web at web speeds up to 3m/minute; 2) Better than 1mm spatial resolution on 60cm wide web; 3) an average better than 20nm spectral resolution resulting in more than sufficient sensitivity to composition imperfections (copper-rich and copper-poor regions were detected). The system was verified to be high vacuum compatible. Phase II results completely validated both technical and economic feasibility of the proposed concept. MicroXact’s solution is an enabling technique for in-line PV manufacturing diagnostics to increase the productivity of PV manufacturing lines and reduce the cost of solar energy, thus reducing the US dependency on foreign oil while simultaneously reducing emission of greenhouse gasses.

  15. ORION laser target diagnostics

    International Nuclear Information System (INIS)

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.

    2012-01-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  16. ORION laser target diagnostics.

    Science.gov (United States)

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  17. Enhanced Fenton-like removal of nitrobenzene via internal microelectrolysis in nano zerovalent iron/activated carbon composite.

    Science.gov (United States)

    Hu, Sihai; Wu, Yaoguo; Yao, Hairui; Lu, Cong; Zhang, Chengjun

    2016-01-01

    The efficiency of Fenton-like catalysis using nano zerovalent iron (nZVI) is limited by nZVI aggregation and activity loss due to inactive ferric oxide forming on the nZVI surface, which hinders electron transfer. A novel iron-carbon composite catalyst consisting of nZVI and granular activated carbon (GAC), which can undergo internal iron-carbon microelectrolysis spontaneously, was successfully fabricated by the adsorption-reduction method. The catalyst efficiency was evaluated in nitrobenzene (NB) removal via the Fenton-like process (H2O2-nZVI/GAC). The results showed that nZVI/GAC composite was good for dispersing nZVI on the surface of GAC, which permitted much better removal efficiency (93.0%) than nZVI (31.0%) or GAC (20.0%) alone. Moreover, iron leaching decreased from 1.28 to 0.58 mg/L after reaction of 240 min and the oxidation kinetic of the Fenton-like reaction can be described well by the second-order reaction kinetic model (R2=0.988). The composite catalyst showed sustainable catalytic ability and GAC performed as a medium for electron transfer in internal iron-carbon microelectrolysis to promote Fe2+ regeneration and Fe3+/Fe2+ cycles. Therefore, this study represents an important method to design a low cost and high efficiency Fenton-like catalyst in practical application.

  18. Systematic Internal Transcribed Spacer Sequence Analysis for Identification of Clinical Mold Isolates in Diagnostic Mycology: a 5-Year Study▿ †

    Science.gov (United States)

    Ciardo, Diana E.; Lucke, Katja; Imhof, Alex; Bloemberg, Guido V.; Böttger, Erik C.

    2010-01-01

    The implementation of internal transcribed spacer (ITS) sequencing for routine identification of molds in the diagnostic mycology laboratory was analyzed in a 5-year study. All mold isolates (n = 6,900) recovered in our laboratory from 2005 to 2009 were included in this study. According to a defined work flow, which in addition to troublesome phenotypic identification takes clinical relevance into account, 233 isolates were subjected to ITS sequence analysis. Sequencing resulted in successful identification for 78.6% of the analyzed isolates (57.1% at species level, 21.5% at genus level). In comparison, extended in-depth phenotypic characterization of the isolates subjected to sequencing achieved taxonomic assignment for 47.6% of these, with a mere 13.3% at species level. Optimization of DNA extraction further improved the efficacy of molecular identification. This study is the first of its kind to testify to the systematic implementation of sequence-based identification procedures in the routine workup of mold isolates in the diagnostic mycology laboratory. PMID:20573873

  19. Exploring the Case for a Global Alliance for Medical Diagnostics Initiative

    Directory of Open Access Journals (Sweden)

    Melissa L. Mugambi

    2017-01-01

    Full Text Available In recent years, the private and public sectors have increased investments in medical diagnostics for low- and middle-income countries (LMICs. Despite these investments, numerous barriers prevent the adoption of existing diagnostics and discourage the development and introduction of new diagnostics in LMICs. In the late 1990s, the global vaccine community had similar challenges, as vaccine coverage rates stagnated and the introduction of new vaccines was viewed as a distraction to delivering existing vaccines. To address these challenges, the international community came together and formed the Global Alliance for Vaccines Initiative (GAVI. Sixteen years after the formation of GAVI, we see evidence of a healthier global vaccine landscape. We discuss how GAVI’s four guiding principles (product, health systems strengthening, financing and market shaping might apply to the advancement of medical diagnostics in LMICs. We present arguments for the international community and existing organizations to establish a Global Alliance for Medical Diagnostics Initiative (GAMDI.

  20. 7th international symposium on internal combustion diagnostics. Proceedings; 7. Internationales Symposium fuer Verbrennungsdiagnostik. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    At one time combustion pressure indicating was the ''trigger'' for this symposium, and today it still serves as the basis for continued investigation of combustion phenomena. It now finds application throughout the development process, as more sophisticated analysis of conventional signals is possible. Understanding of localized combustion phenomena is substantially simplified by means of optical diagnostic methods, the application of which has reached a certain level of standardization. The presentations will cover specific topics including fuel spray analysis, ignition events and information about gas mixtures. The comparison and combination of results from measurement and simulation shed light on the complex processes in the combustion chamber. What's more, the linkage of two complementary methods offers substantial cost savings through reductions in test hardware and shorter development times. Focused application of all of the available tools allows us better to understand combustion processes, recognize the influential parameters and derive control algorithms. The latter are subsequently to be found in engines that fulfill both regulatory requirements and customer expectations. So it is that the symposium captures the current state of the art in combustion diagnostics through a combination of indicating, optical diagnostics and simulation, and offers both the methodology expert and the engine developer the ideal platform for discussion of today's issues - and to form their own opinions on them. Anyone wanting to keep up to date in this continuously developing and ever more complex area of activity certainly can't afford to miss our symposium. (orig.)

  1. Schistosoma real-time PCR as diagnostic tool for international travellers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Tannich, Egbert; Polman, Katja; Clerinx, Jan; Van Esbroeck, Marjan

    2012-10-01

    To evaluate the use of a genus-specific PCR that combines high sensitivity with the detection of different Schistosoma species for diagnosis in international travellers and migrants in comparison to standard microscopy. The genus-specific real-time PCR was developed to target the 28S ribosomal RNA gene of the major human Schistosoma species. It was validated for analytical specificity and reproducibility and demonstrated an analytical sensitivity of 0.2 eggs per gram of faeces. Its diagnostic performance was further evaluated on 152 faecal, 32 urine and 38 serum samples from patients presenting at the outpatient clinic of the Institute of Tropical Medicine in Antwerp (Belgium). We detected Schistosoma DNA in 76 faecal (50.0%) and five urine (15.6%) samples of which, respectively, nine and one were not detected by standard microscopy. Only two of the 38 serum samples of patients with confirmed schistosomiasis were positive with the presently developed PCR. Sequence analysis on positive faecal samples allowed identification of the Schistosoma species complex. The real-time PCR is highly sensitive and may offer added value in diagnosing imported schistosomiasis. The genus-specific PCR can detect all schistosome species that are infectious to humans and performs very well with faeces and urine, but not in serum. © 2012 Blackwell Publishing Ltd.

  2. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 – 2016 Ebola outbreak in West Africa

    Science.gov (United States)

    Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-01-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied. PMID:28459810

  3. Routine internal- and external-quality control data in clinical laboratories for estimating measurement and diagnostic uncertainty using GUM principles.

    Science.gov (United States)

    Magnusson, Bertil; Ossowicki, Haakan; Rienitz, Olaf; Theodorsson, Elvar

    2012-05-01

    Healthcare laboratories are increasingly joining into larger laboratory organizations encompassing several physical laboratories. This caters for important new opportunities for re-defining the concept of a 'laboratory' to encompass all laboratories and measurement methods measuring the same measurand for a population of patients. In order to make measurement results, comparable bias should be minimized or eliminated and measurement uncertainty properly evaluated for all methods used for a particular patient population. The measurement as well as diagnostic uncertainty can be evaluated from internal and external quality control results using GUM principles. In this paper the uncertainty evaluations are described in detail using only two main components, within-laboratory reproducibility and uncertainty of the bias component according to a Nordtest guideline. The evaluation is exemplified for the determination of creatinine in serum for a conglomerate of laboratories both expressed in absolute units (μmol/L) and relative (%). An expanded measurement uncertainty of 12 μmol/L associated with concentrations of creatinine below 120 μmol/L and of 10% associated with concentrations above 120 μmol/L was estimated. The diagnostic uncertainty encompasses both measurement uncertainty and biological variation, and can be estimated for a single value and for a difference. This diagnostic uncertainty for the difference for two samples from the same patient was determined to be 14 μmol/L associated with concentrations of creatinine below 100 μmol/L and 14 % associated with concentrations above 100 μmol/L.

  4. Carbon Fiber Reinforced Carbon Composite Rotary Valve for an Internal Combustion Engine

    Science.gov (United States)

    Northam, G.Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    2000-01-01

    Carbon fiber reinforced carbon composite rotary sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or wrap-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties do not present the sealing and lubrication problems that have prevented rotary sleeve and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  5. Towards diagnostics for a fusion reactor

    International Nuclear Information System (INIS)

    Costley, A. E.

    2009-01-01

    The requirements for measurements on modern tokamak fusion plasmas are outlined, and the techniques and systems used to make the measurements, usually referred to as 'diagnostics', are introduced. The basics of three particular diagnostics - magnetics, neutron systems and a laser based optical system - are outlined as examples of modern diagnostic systems, and the implementation of these diagnostics on a current tokamak (JET) are described. The next major step in magnetic confinement fusion is the construction and operation of the International Thermonuclear Experimental Reactor (ITER), which is a joint project of China, Europe, Japan, India, Korea, the Russian Federation, and the United States. Construction has begun in Cadarache, France. It is expected that ITER will operate at the 500 MW level. Because of the harsh environment in the vacuum vessel where many diagnostic components are located, the development of diagnostics for ITER is a major challenge - arguably the most difficult challenge ever undertaken in the field of diagnostics. The main elements in the diagnostic step are outlined using the three chosen techniques as examples. Finally, the step beyond ITER to a demonstration reactor, DEMO, that is expected to produce several GWs of fusion power is considered and the impact on diagnostics outlined. It is shown that the applicability and development steps needed for the individual diagnostics techniques will differ. The challenges for DEMO diagnostics are substantial and a dedicated effort should be made to find and develop new techniques, and especially techniques appropriate to the DEMO environment. It is argued that the limitations and difficulties in diagnostics should be a consideration in the optimization and designs of DEMO. (author)

  6. An approach to local diagnostic reference levels (DRL's) in the context of national and international DRL's

    International Nuclear Information System (INIS)

    Rogers, A.T.

    2001-01-01

    In recent years there has been a greater focus on the management of patient doses. This effort has been driven by the realisation of both the increasing magnitude of patient doses and their variation both intra- and inter-nationally. Legislators and guidance-issuing bodies have developed the idea of 'Diagnostic Reference Levels' (DRL's). In particular, the European Union, in their Council Directive 97/43/Euratom, required Member States to develop DRL's. The UK Government, when consolidating this EU Directive into UK legislation, extended the concept of DRL's from a national to an employer level. However, the methodologies used for development of national and international DRL's do not translate to a local level and hence a new approach is required. This paper describes one particular approach made by a UK hospital to introduce 'Local DRL's' in such a manner as to aid the optimisation process. This approach utilises a dose index, based on the local patient population, which is monitored for trends. Any trend in patient dose triggers an investigation linked to the clinical audit system within the Clinical Radiology Department. It is the audit cycle that ensures a continuing move towards an optimised situation. Additional triggers may be employed such as large patient dose variations. (author)

  7. Godiva and Juliet Diagnostics CED-1 (IER-176)

    Energy Technology Data Exchange (ETDEWEB)

    Scorby, J C

    2011-12-21

    A suite of diagnostics are being proposed for use in the Juliet experiment (IER-128). In order to calibrate and test the diagnostics prior to use, the LLNL calibration facility and Godiva pulsed reactor will be used to provide intense sources of neutrons and gammas. Due to the similarities of the Godiva and Juliet radiation fields, the diagnostics being developed and tested for Juliet can also play an on-going role in diagnostics for Godiva as well as, perhaps, other critical assembly experiments. Similar work is also being conducted for IER-147 for the purpose of characterizing the Godiva radiation field in support of an upcoming international nuclear accident dosimetry exercise. Diagnostics developed and fielded under IER-147 can provide valuable data with respect to the neutron and gamma energy spectrums in the vicinity of Godiva which is relevant to the calibration of Juliet diagnostics.

  8. The diagnostic value of the premature ejaculation diagnostic tool and its association with intravaginal ejaculatory latency time.

    Science.gov (United States)

    Kam, Sung Chul; Han, Deok Hyun; Lee, Sung Won

    2011-03-01

    Premature ejaculation (PE) is the most prevalent male ejaculation disorder. The premature ejaculation diagnostic tool (PEDT) was developed to systematically apply the DSM-IV-TR criteria in diagnostic PE. To evaluate the diagnostic value of the PEDT and its association with intravaginal ejaculatory latency time (IELT). (i) Korean validation of PEDT: data was collected from men interviewed by one of the two clinical experts, who made a diagnostic of present or absence of PE, using DSM-IV-TR criteria. A total of 103 patients with PE and 100 men without PE were enrolled into the study and requested to complete the PEDT; and (ii) The correlation between IELT and PEDT: 200 participants were enrolled and each participant was asked to make out PEDT. All participants were requested to measure IELT. Validity and reliability of the PEDT and its association with IELT. The geometric mean IELT of the PE group was 115.37 ± 78.14 seconds. The number of men reporting IELTs of 2 minutes were 28 (28.6%), 29 (29.6%), and 41 (41.8%), respectively. The Cronbach's alpha score was calculated as 0.93, showing adequate internal consistency. The test-retest correlation coefficients of each item were higher than 0.72 and the correlation coefficients of the total score was 0.88. (P IELT showed an adequate negative correlation. (ρ = -0.77, P IELT ≤ 2 minutes) and IELT showed a negative correlation. (ρ = -0.6, P < 0.0001) The PEDT was highly effective in detecting the presence of PE. The result of our study supports its validity as a diagnostic tool in the clinical setting. © 2010 International Society for Sexual Medicine.

  9. Towards better description of solar activity variation in the International Reference Ionosphere topside ion composition model

    Czech Academy of Sciences Publication Activity Database

    Truhlík, Vladimír; Bilitza, D.; Třísková, Ludmila

    2015-01-01

    Roč. 55, č. 8 (2015), s. 2099-2105 ISSN 0273-1177 R&D Projects: GA MŠk(CZ) LH11123 Institutional support: RVO:68378289 Keywords : ion composition * topside ionosphere * solar activity * empirical model * International Reference Ionosphere Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.409, year: 2015 http://www.sciencedirect.com/science/article/pii/S027311771400489X

  10. Expanding the taxonomy of the diagnostic criteria for temporomandibular disorders.

    Science.gov (United States)

    Peck, C C; Goulet, J-P; Lobbezoo, F; Schiffman, E L; Alstergren, P; Anderson, G C; de Leeuw, R; Jensen, R; Michelotti, A; Ohrbach, R; Petersson, A; List, T

    2014-01-01

    There is a need to expand the current temporomandibular disorders' (TMDs) classification to include less common but clinically important disorders. The immediate aim was to develop a consensus-based classification system and associated diagnostic criteria that have clinical and research utility for less common TMDs. The long-term aim was to establish a foundation, vis-à-vis this classification system, that will stimulate data collection, validity testing and further criteria refinement. A working group [members of the International RDC/TMD Consortium Network of the International Association for Dental Research (IADR), members of the Orofacial Pain Special Interest Group (SIG) of the International Association for the Study of Pain (IASP), and members from other professional societies] reviewed disorders for inclusion based on clinical significance, the availability of plausible diagnostic criteria and the ability to operationalise and study the criteria. The disorders were derived from the literature when possible and based on expert opinion as necessary. The expanded TMDs taxonomy was presented for feedback at international meetings. Of 56 disorders considered, 37 were included in the expanded taxonomy and were placed into the following four categories: temporomandibular joint disorders, masticatory muscle disorders, headache disorders and disorders affecting associated structures. Those excluded were extremely uncommon, lacking operationalised diagnostic criteria, not clearly related to TMDs, or not sufficiently distinct from disorders already included within the taxonomy. The expanded TMDs taxonomy offers an integrated approach to clinical diagnosis and provides a framework for further research to operationalise and test the proposed taxonomy and diagnostic criteria. © 2014 John Wiley & Sons Ltd.

  11. Diagnostic criteria for headache attributed to temporomandibular disorders.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; List, Thomas; Anderson, Gary; Jensen, Rigmor; John, Mike T; Nixdorf, Donald; Goulet, Jean-Paul; Kang, Wenjun; Truelove, Ed; Clavel, Al; Fricton, James; Look, John

    2012-07-01

    We assessed and compared the diagnostic accuracy of two sets of diagnostic criteria for headache secondary to temporomandibular disorders (TMD). In 373 headache subjects with TMD, a TMD headache reference standard was defined as: self-reported temple headache, consensus diagnosis of painful TMD and replication of the temple headache using TMD-based provocation tests. Revised diagnostic criteria for Headache attributed to TMD were selected using the RPART (recursive partitioning and regression trees) procedure, and refined in half of the data set. Using the remaining half of the data, the diagnostic accuracy of the revised criteria was compared to that of the International Headache Society's International Classification of Headache Diseases (ICHD)-II criteria A to C for Headache or facial pain attributed to temporomandibular joint (TMJ) disorder. Relative to the TMD headache reference standard, ICHD-II criteria showed sensitivity of 84% and specificity of 33%. The revised criteria for Headache attributed to TMD had sensitivity of 89% with improved specificity of 87% (p headache that is changed with jaw movement, function or parafunction and (2) provocation of that headache by temporalis muscle palpation or jaw movement. Having significantly better specificity than the ICHD-II criteria A to C, the revised criteria are recommended to diagnose headache secondary to TMD.

  12. Diagnostic reference levels in medical imaging

    International Nuclear Information System (INIS)

    Rosenstein, M.

    2001-01-01

    The paper proposes additional advice to national or local authorities and the clinical community on the application of diagnostic reference levels as a practical tool to manage radiation doses to patients in diagnostic radiology and nuclear medicine. A survey was made of the various approaches that have been taken by authoritative bodies to establish diagnostic reference levels for medical imaging tasks. There are a variety of ways to implement the idea of diagnostic reference levels, depending on the medical imaging task of interest, the national or local state of practice and the national or local preferences for technical implementation. The existing International Commission on Radiological Protection (ICRP) guidance is reviewed, the survey information is summarized, a set of unifying principles is espoused and a statement of additional advice that has been proposed to ICRP Committee 3 is presented. The proposed advice would meet a need for a unifying set of principles to provide a framework for diagnostic reference levels but would allow flexibility in their selection and use. While some illustrative examples are given, the proposed advice does not specify the specific quantities to be used, the numerical values to be set for the quantities or the technical details of how national or local authorities should implement diagnostic reference levels. (author)

  13. Structural Diagnostics of CFRP Composite Aircraft Components by Ultrasonic Guided Waves and Built-In Piezoelectric Transducers

    Energy Technology Data Exchange (ETDEWEB)

    Matt, Howard M. [Univ. of California, San Diego, CA (United States)

    2006-01-01

    To monitor in-flight damage and reduce life-cycle costs associated with CFRP composite aircraft, an autonomous built-in structural health monitoring (SHM) system is preferred over conventional maintenance routines and schedules. This thesis investigates the use of ultrasonic guided waves and piezoelectric transducers for the identification and localization of damage/defects occurring within critical components of CFRP composite aircraft wings, mainly the wing skin-to-spar joints. The guided wave approach for structural diagnostics was demonstrated by the dual application of active and passive monitoring techniques. For active interrogation, the guided wave propagation problem was initially studied numerically by a semi-analytical finite element method, which accounts for viscoelastic damping, in order to identify ideal mode-frequency combinations sensitive to damage occurring within CFRP bonded joints. Active guided wave tests across three representative wing skin-to-spar joints at ambient temperature were then conducted using attached Macro Fiber Composite (MFC) transducers. Results from these experiments demonstrate the importance of intelligent feature extraction for improving the sensitivity to damage. To address the widely neglected effects of temperature on guided wave base damage identification, analytical and experimental analyses were performed to characterize the influence of temperature on guided wave signal features. In addition, statistically-robust detection of simulated damage in a CFRP bonded joint was successfully achieved under changing temperature conditions through a dimensionally-low, multivariate statistical outlier analysis. The response of piezoceramic patches and MFC transducers to ultrasonic Rayleigh and Lamb wave fields was analytically derived and experimentally validated. This theory is useful for designing sensors which possess optimal sensitivity toward a given mode-frequency combination or for predicting the frequency dependent

  14. Edge diagnostics for tandem mirror machines

    International Nuclear Information System (INIS)

    Allen, S.L.

    1984-01-01

    The edge plasma in a tandem mirror machine shields the plasma core from cold neutral gas and impurities. A variety of diagnostics are used to measure the fueling, shielding, and confinement of the edge plasma in both the end plug and central cell regions. Fast ion gauges and residual gas analyzers measure the gas pressure and composition outside of the plasma. An array of Langmuir probes is used to measure the electron density and temperature. Extreme ultraviolet (euv) and visible spectroscopy are used to measure both the impurity and deuterium densities and to estimate the shielding factor for the core plasma. The linear geometry of a tandem mirror also allows direct measurements of the edge plasma by sampling the ions and electrons lost but the ends of the machine. Representative data obtained by these diagnostics during operation of the Tandem Mirror Experiment (TMX) and Tandem Mirror Experiment-Upgrade (TMX-U) experiments are presented. Diagnostics that are currently being developed to diagnose the edge plasma are also discussed

  15. “Burning Plasma” Diagnostics for the Physics of JET and ITER

    Czech Academy of Sciences Publication Activity Database

    Murari, A.; Bertalot, L.; Bonheure, G.; Conroy, S.; Ericsson, G.; Kiptily, V.G.; Lawson, K.; Popovichev, S.; Tardocchi, M.; Afanasyiev, V.; Angelone, M.; Fasoli, A.; Kallne, J.; Mironov, M.; Mlynář, Jan; Testa, D.; Zastrow, K.D.

    2005-01-01

    Roč. 47, 12B (2005), B249-B262 ISSN 0741-3335. [EPS Conference on Plasma Physics/32nd./. Tarragona, 27.6.2005-1.7.2005] Institutional research plan: CEZ:AV0Z20430508 Keywords : JET * ITER * neutrons diagnostics * alphas diagnostics * burning plasma * reactor * isotopic composition Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.902, year: 2005 http://eps2005.ciemat.es

  16. HEPATORENAL SYNDROME: DIAGNOSTIC AND THERAPEUTIC MANAGEMENT

    Directory of Open Access Journals (Sweden)

    I. G. Bakulin

    2014-01-01

    Full Text Available The practical guidelines on diagnosis and management of hepatorenal syndrome, which could be useful for general medical practitioners, gastroenterologists, and hepatologists, are considered in this paper. Selected recommendations are based on integrated clinical data, international recommendations and results of clinical trials. Beginning from theoretical grounds of hepatorenal syndrome (its definition, diagnostic criteria, and classification, acute kidney injury, and spontaneous bacterial peritonitis, the paper contains diagnostic algorithms (in particular, in ascites, for early revealing hepatorenal syndrome, and main approaches to therapy and prevention. The efficacy criteria and monitoring rules for the terlipressin-based therapy are listed.

  17. [An exploratory study on the diagnostic cutoff value of International HIV-associated Dementia Scale in minority ethnic groups with different educational levels, in Guangxi].

    Science.gov (United States)

    Zhao, Ting-ting; Feng, Qi-ming; Liang, Hao; Tang, Xian-yan; Wei, Bo

    2011-11-01

    Using Intelligence Scale of Mini Mental State Estimated (MMSE) as the gold standard to determine the relevance of International HIV-associated Dementia Scale (IHDS) in minority ethnic areas in Guangxi populations with different cultural values. Corresponding boundary value related to the authenticity and reliability on IHDS were also evaluated. 200 patients with HIV infection were randomly selected from the minority ethnic groups in Guangxi. For each infected person, MMSE and IHDS blind scale were tested at the same period. Using the results from MMSE scale test as the gold standard, ROC curve and IHDS scale in Guangxi minority populations with different education levels which related to the diagnosis of dementia-HIV values were determined. The value of a specific sector under the IHDS sensitivity, specificity, and internal consistency coefficients was also evaluated. When considering the infected person did not differ on their educational level, the IHDS scale diagnostic cutoff appeared as 8.25, while IHDS sensitivity as 0.925, specificity as 0.731 and Kappa as 0.477 (P education groups showed different IHDS diagnostic cutoff values. People with high school, secondary school or higher education levels, the IHDS diagnosis appeared to be 8.25, when sensitivity was 0.917, specificity was 0.895 and Kappa was 0.722 (P education level, the IHDS appeared to be 7.25. When sensitivity was 0.875, specificity was 0.661 and Kappa was 0.372 (P value (IHDS ≤ 10 points). When using IHDS to perform the HIV related dementia screening program, in the minority areas of Guangxi, culture context, the degree and difference of HIV infection should be considered, especially in using IHDS diagnostic cutoff values.

  18. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  19. Molecular Diagnostics of ?-Thalassemia

    OpenAIRE

    Atanasovska, B; Bozhinovski, G; Chakalova, L; Kocheva, S; Karanfilski, O; Plaseska-Karanfiska, D

    2012-01-01

    A high-quality hemoglobinopathy diagnosis is based on the results of a number of tests including assays for molecular identification of causative mutations. We describe the current diagnostic strategy for the identification of ?-thalassemias and hemoglobin (Hb) variants at the International Reference Laboratory for Haemoglobinopathies, Research Centre for Genetic Engineering and Biotechnology (RCGEB) ?Georgi D. Efremov,? Skopje, Republic of Macedonia. Our overall approach and most of the meth...

  20. Factor structure and diagnostic efficiency of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria for avoidant personality disorder in Hispanic men and women with substance use disorders.

    Science.gov (United States)

    Becker, Daniel F; Añez, Luis Miguel; Paris, Manuel; Bedregal, Luis; Grilo, Carlos M

    2009-01-01

    This study examined the internal consistency, factor structure, and diagnostic efficiency of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), criteria for avoidant personality disorder (AVPD) and the extent to which these metrics may be affected by sex. Subjects were 130 monolingual Hispanic adults (90 men, 40 women) who had been admitted to a specialty clinic that provides psychiatric and substance abuse services to Spanish-speaking patients. All were reliably assessed with the Spanish-Language Version of the Diagnostic Interview for DSM-IV Personality Disorders. The AVPD diagnosis was determined by the best-estimate method. After evaluating internal consistency of the AVPD criterion set, an exploratory factor analysis was performed using principal components extraction. Afterward, diagnostic efficiency indices were calculated for all AVPD criteria. Subsequent analyses examined men and women separately. For the overall group, internal consistency of AVPD criteria was good. Exploratory factor analysis revealed a 1-factor solution (accounting for 70% of the variance), supporting the unidimensionality of the AVPD criterion set. The best inclusion criterion was "reluctance to take risks," whereas "interpersonally inhibited" was the best exclusion criterion and the best predictor overall. When men and women were examined separately, similar results were obtained for both internal consistency and factor structure, with slight variations noted between sexes in the patterning of diagnostic efficiency indices. These psychometric findings, which were similar for men and women, support the construct validity of the DSM-IV criteria for AVPD and may also have implications for the treatment of this particular clinical population.

  1. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  2. A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries

    Science.gov (United States)

    McDonald, Robert C.; VanBlarcom, Shelly L.; Kwasnik, Katherine E.

    2013-01-01

    A document discusses a thin layer of composite material, made from nano scale particles of nickel and Teflon, placed within a battery cell as a layer within the anode and/or the cathode. There it conducts electrons at room temperature, then switches to an insulator at an elevated temperature to prevent thermal runaway caused by internal short circuits. The material layer controls excess currents from metal-to-metal or metal-to-carbon shorts that might result from cell crush or a manufacturing defect

  3. A 12-week rehabilitation program improves body composition, pain sensation, and internal/external torques of baseball pitchers with shoulder impingement symptom.

    Science.gov (United States)

    Cha, Jun-Youl; Kim, Jae-Hak; Hong, Ju; Choi, Young-Tae; Kim, Min-Ho; Cho, Ji-Hyun; Ko, Il-Gyu; Jee, Yong-Seok

    2014-02-01

    The aim of this study was to investigate the effects of a 12-week rehabilitation program on body composition, shoulder pain, and isokinetic internal/external torques of pitchers with impingement syndrome. A total of 30 pitchers were divided into 2 groups: experimental group (EG, n = 16) and control group (CG, n= 14). The rehabilitation program consisted of physical therapy, warm-up, work-out, and cool-down. As results, body weight and fat mass of EG were decreased whereas muscle mass of EG was significantly increased after the experiment. The pain degrees in resting, normal daily activity, and strenuous activity on the numeric pain rating scale were significantly decreased in the EG. The internal and external peak torques (PTs) of uninvolved and involved sides of EG were increased in EG after 12 weeks. Such results provide a deficit ratio of both sides in EG close to normal values. The ratios of internal/external PTs in EG were also close to the reference values. The internal and external total works of both sides in EG were similar to the values of PT. The fatigue indices of internal and external rotators of both sides in EG were decreased. As a conclusion, a 12-week rehabilitation program reduced the shoulder pain, improved the body composition and enhanced the isokinetic shoulder internal/external rotators in EG with impingement symptoms. Also the study suggested that the rehabilitation program evened out the ratio between internal and external rotators and lowered the fatigue level after the experiment.

  4. NEURAL NETWORK SYSTEM FOR DIAGNOSTICS OF AVIATION DESIGNATION PRODUCTS

    Directory of Open Access Journals (Sweden)

    В. Єременко

    2011-02-01

    Full Text Available In the article for solving the classification problem of the technical state of the  object, proposed to use a hybrid neural network with a Kohonen layer and multilayer perceptron. The information-measuring system can be used for standardless diagnostics, cluster analysis and to classify the products which made from composite materials. The advantage of this architecture is flexibility, high performance, ability to use different methods for collecting diagnostic information about unit under test, high reliability of information processing

  5. Real-Time Remote Diagnostic Monitoring Test-bed in JET

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R. [Asociation Euratom/CIEMAT para Fusion, Madrid (Spain); Kneupner, K.; Purahoo, K. [EURATOM/UKAEA Fusion Association, Abingdon (United Kingdom); Vega, J.; Pereira, A.; Portas, A. [Association EuratomCIEMAT para Fusion, Madrid (Spain); De Arcas, G.; Lopez, J.M. [Universidad Politecnica de Madrid (Spain); Murari, A. [Consorzio RFX, Padova (Italy); Fonseca, A. [Associacao URATOM/IST, Lisboa (Portugal); Contributors, J.E. [JET-EFDA, Abingdon (United Kingdom)

    2009-07-01

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. It integrates 2 functionalities. The first one is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The second one is the integration of dotJET (Diagnostic Overview Tool for JET), which internally provides at JET an overview about the current diagnostic systems state, in order to monitor, on remote, JET diagnostics status. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there are two data generators: the acquisition equipment associated with the reflectometer diagnostic that generates data and status information, and dotJET server that centralize the access to the status information of JET diagnostics. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on Java Web Start technology, and a dotJET client application have been used. There are 3 interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of a flexible enough architecture, to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements; and the third one is to have achieved a secure system, taking into account internal networks and firewalls aspects in JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to

  6. Effects of host cell sterol composition upon internalization of Yersinia pseudotuberculosis and clustered β1 integrin.

    Science.gov (United States)

    Kim, JiHyun; Fukuto, Hana S; Brown, Deborah A; Bliska, James B; London, Erwin

    2018-01-26

    Yersinia pseudotuberculosis is a foodborne pathogenic bacterium that causes acute gastrointestinal illness, but its mechanisms of infection are incompletely described. We examined how host cell sterol composition affected Y. pseudotuberculosis uptake. To do this, we depleted or substituted cholesterol in human MDA-MB-231 epithelial cells with various alternative sterols. Decreasing host cell cholesterol significantly reduced pathogen internalization. When host cell cholesterol was substituted with various sterols, only desmosterol and 7-dehydrocholesterol supported internalization. This specificity was not due to sterol dependence of bacterial attachment to host cells, which was similar with all sterols studied. Because a key step in Y. pseudotuberculosis internalization is interaction of the bacterial adhesins invasin and YadA with host cell β1 integrin, we compared the sterol dependence of wildtype Y. pseudotuberculosis internalization with that of Δ inv , Δ yadA , and Δ inv Δ yadA mutant strains. YadA deletion decreased bacterial adherence to host cells, whereas invasin deletion had no effect. Nevertheless, host cell sterol substitution had a similar effect on internalization of these bacterial deletion strains as on the wildtype bacteria. The Δ inv Δ yadA double mutant adhered least to cells and so was not significantly internalized. The sterol structure dependence of Y. pseudotuberculosis internalization differed from that of endocytosis, as monitored using antibody-clustered β1 integrin and previous studies on other proteins, which had a more permissive sterol dependence. This study suggests that agents could be designed to interfere with internalization of Yersinia without disturbing endocytosis. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.

  7. Micromechanical Models for Composite NDE and Diagnostics, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Modern aircraft (and next generation spacecraft) increasingly rely on composite components due to their excellent specific strength and stiffness, as well as...

  8. Status of ITER neutron diagnostic development

    Science.gov (United States)

    Krasilnikov, A. V.; Sasao, M.; Kaschuck, Yu. A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V. S.; Popovichev, S.; Iguchi, T.; Jarvis, O. N.; Källne, J.; Fiore, C. L.; Roquemore, A. L.; Heidbrink, W. W.; Fisher, R.; Gorini, G.; Prosvirin, D. V.; Tsutskikh, A. Yu.; Donné, A. J. H.; Costley, A. E.; Walker, C. I.

    2005-12-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented.

  9. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Krasilnikov, A.V.; Sasao, M.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Iguchi, T.; Jarvis, O.N.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Prosvirin, D.V.; Tsutskikh, A.Yu.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be measured well by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors (NFMs), neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The NFMs need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented

  10. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Sasao, M.; Krasilnikov, A.V.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Jarvis, O.N.; Iguchi, T.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be well measured by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include: radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors, neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The neutron flux monitors need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented. (author)

  11. Development of an Internal Real-Time Wireless Diagnostic Tool for a Proton Exchange Membrane Fuel Cell.

    Science.gov (United States)

    Lee, Chi-Yuan; Chen, Chia-Hung; Tsai, Chao-Hsuan; Wang, Yu-Syuan

    2018-01-13

    To prolong the operating time of unmanned aerial vehicles which use proton exchange membrane fuel cells (PEMFC), the performance of PEMFC is the key. However, a long-term operation can make the Pt particles of the catalyst layer and the pollutants in the feedstock gas bond together (e.g., CO), so that the catalyst loses reaction activity. The performance decay and aging of PEMFC will be influenced by operating conditions, temperature, flow and CO concentration. Therefore, this study proposes the development of an internal real-time wireless diagnostic tool for PEMFC, and uses micro-electro-mechanical systems (MEMS) technology to develop a wireless and thin (PEMFC; (5) customized design and development. The flexible integrated microsensor is embedded in the PEMFC, three important physical quantities in the PEMFC, which are the temperature, flow and CO, can be measured simultaneously and instantly, so as to obtain the authentic and complete reaction in the PEMFC to enhance the performance of PEMFC and to prolong the service life.

  12. Parametric study on nonlinear vibration of composite truss core sandwich plate with internal resonance

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jia Nen; Liu, Jun [Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin (China); Zhang, Wei; Yao, Ming Hui [College of Mechanical Engineering, Beijing University of Technology, Beijing (China); Sun, Min [School of Science, Tianjin Chengjian University, Tianjin (China)

    2016-09-15

    Nonlinear vibrations of carbon fiber reinforced composite sandwich plate with pyramidal truss core are investigated. The governing equation of motion for the sandwich plate is derived by using a Zig-Zag theory under consideration of geometrically nonlinear. The natural frequencies of sandwich plates with different dimensions are calculated and compared with those obtained from the classic laminated plate theory and Reddy's third-order shear deformation plate theory. The frequency responses and waveforms of the sandwich plate when 1:3 internal resonance occurs are obtained, and the characteristics of the internal resonance are discussed. The influences of layer number of face sheet, strut radius, core height and inclination angle on the nonlinear responses of the sandwich plate are analyzed. The results demonstrate that the strut radius and inclination angle mainly affect the resonance frequency band of the sandwich plate, and the layer number and core height not only influence the resonance frequency band but also significantly affect the response amplitude.

  13. Validation of cytogenetic risk groups according to International Prognostic Scoring Systems by peripheral blood CD34+FISH: results from a German diagnostic study in comparison with an international control group

    Science.gov (United States)

    Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H.; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A. N.; Lübbert, Michael; Greenberg, Peter L.; Bennett, John M.; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L.; Ohyashiki, Kazuma; Le Beau, Michelle M.; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R.; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie

    2015-01-01

    International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%–20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34+) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34+ peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34+ blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). PMID:25344522

  14. Validation of cytogenetic risk groups according to International Prognostic Scoring Systems by peripheral blood CD34+FISH: results from a German diagnostic study in comparison with an international control group.

    Science.gov (United States)

    Braulke, Friederike; Platzbecker, Uwe; Müller-Thomas, Catharina; Götze, Katharina; Germing, Ulrich; Brümmendorf, Tim H; Nolte, Florian; Hofmann, Wolf-Karsten; Giagounidis, Aristoteles A N; Lübbert, Michael; Greenberg, Peter L; Bennett, John M; Solé, Francesc; Mallo, Mar; Slovak, Marilyn L; Ohyashiki, Kazuma; Le Beau, Michelle M; Tüchler, Heinz; Pfeilstöcker, Michael; Nösslinger, Thomas; Hildebrandt, Barbara; Shirneshan, Katayoon; Aul, Carlo; Stauder, Reinhard; Sperr, Wolfgang R; Valent, Peter; Fonatsch, Christa; Trümper, Lorenz; Haase, Detlef; Schanz, Julie

    2015-02-01

    International Prognostic Scoring Systems are used to determine the individual risk profile of myelodysplastic syndrome patients. For the assessment of International Prognostic Scoring Systems, an adequate chromosome banding analysis of the bone marrow is essential. Cytogenetic information is not available for a substantial number of patients (5%-20%) with dry marrow or an insufficient number of metaphase cells. For these patients, a valid risk classification is impossible. In the study presented here, the International Prognostic Scoring Systems were validated based on fluorescence in situ hybridization analyses using extended probe panels applied to cluster of differentiation 34 positive (CD34(+)) peripheral blood cells of 328 MDS patients of our prospective multicenter German diagnostic study and compared to chromosome banding results of 2902 previously published patients with myelodysplastic syndromes. For cytogenetic risk classification by fluorescence in situ hybridization analyses of CD34(+) peripheral blood cells, the groups differed significantly for overall and leukemia-free survival by uni- and multivariate analyses without discrepancies between treated and untreated patients. Including cytogenetic data of fluorescence in situ hybridization analyses of peripheral CD34(+) blood cells (instead of bone marrow banding analysis) into the complete International Prognostic Scoring System assessment, the prognostic risk groups separated significantly for overall and leukemia-free survival. Our data show that a reliable stratification to the risk groups of the International Prognostic Scoring Systems is possible from peripheral blood in patients with missing chromosome banding analysis by using a comprehensive probe panel (clinicaltrials.gov identifier:01355913). Copyright© Ferrata Storti Foundation.

  15. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-01-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next

  16. Experimental investigation of internal short circuits in lithium-ion batteries

    Science.gov (United States)

    Poramapojana, Poowanart

    With outstanding performance of Lithium-ion batteries, they have been widely used in many applications. For hybrid electric vehicles and electric vehicles, customer concerns of battery safety have been raised as a number of car accidents were reported. To evaluate safety performance of these batteries, a nail penetration test is used to simulate and induce internal short circuits instantaneously. Efforts to explain failure mechanisms of the penetration using electrochemical-thermal coupled models have been proposed. However, there is no experimental validation because researchers lack of a diagnostic tool to acquire important cell characteristics at a shorting location, such as shorting current and temperature. In this present work, diagnostic nails have been developed to acquire nail center temperatures and shorting current flow through the nails during nail penetration tests. Two types of cylindrical wall structures are used to construct the nails: a double-layered stainless steel wall and a composite cylindrical wall. An inner hollow cylinder functions as a sensor holder where two wires and one thermocouple are installed. To study experimental reproducibility and repeatability of experimental results, two nail penetration tests are conducted using two diagnostic nails with the double-layered wall. Experimental data shows that the shorting resistance at the initial stage is a critical parameter to obtain repeatable results. The average shorting current for both tests is approximately 40 C-rate. The fluctuation of the shorting current is due to random sparks and fire caused loose contacts between the nail and the cell components. Moreover, comparative experimental results between the two wall structures reveal that the wall structure does not affect the cell characteristics and Ohmic heat generation of the nail. The wall structure effects to current measurements inside the nail. With the composite wall, the actual current redistribution into the inner wall is

  17. Dew point, internal gas pressure, and chemical composition of the gas within the free volume of DWPF canistered waste forms

    International Nuclear Information System (INIS)

    Harbour, J.R.; Herman, D.T.; Crump, S.; Miller, T.J.; McIntosh, J.

    1996-01-01

    The Defense Waste Processing Facility (DWPF) produced 55 canistered waste forms containing simulated waste glass during the four Waste Qualification campaigns of the DWPF Startup Test Program. Testing of the gas within the free volume of these canisters for dew point, internal gas pressure, and chemical composition was performed as part of a continuing effort to demonstrate compliance with the Waste Acceptance Product Specifications. Results are presented for six glass-filled canisters. The dew points within the canisters met the acceptance criterion of < 20 degrees C for all six canisters. Factors influencing the magnitude of the dew point are presented. The chemical composition of the free volume gas was indistinguishable from air for all six canisters. Hence, no foreign materials were present in the gas phase of these canisters. The internal gas pressures within the sealed canisters were < 1 atm at 25 degrees C for all six canisters which readily met the acceptance criterion of an internal gas pressure of less than 1.5 atm at 25 degrees C. These results provided the evidence required to demonstrate compliance with the Waste Acceptance Product Specifications

  18. Applicability of the 2001 revised diagnostic criteria in Brazilian Vogt-Koyanagi-Harada disease patients.

    Science.gov (United States)

    Cardoso, Isabel Habeyche; Zajdenweber, Moysés Eduardo; Muccioli, Cristina; Fimamor, Luciana Peixoto; Belfort, Rubens

    2008-01-01

    To determine the applicability of the international revised diagnostic criteria for Vogt-Koyanagi-Harada disease. Retrospective study. Medical charts of 140 patients with the diagnosis of Vogt-Koyanagi-Harada disease, from the Uveitis Sector of the Federal University of Sao Paulo (UNIFESP), were revised and classified following the revised diagnostic criteria. Of the 140 patients, 12.85% fulfilled the criteria for complete disease, 29.28% incomplete disease, 28.57% "probable" Vogt-Koyanagi-Harada disease and 28.27% were considered not Vogt-Koyanagi-Harada disease. The authors consider that the international revised diagnostic criteria have good applicability and are very useful to help in the diagnosis of Vogt-Koyanagi-Harada disease.

  19. Pre-examination factors affecting molecular diagnostic test results and interpretation: A case-based approach.

    Science.gov (United States)

    Payne, Deborah A; Baluchova, Katarina; Peoc'h, Katell H; van Schaik, Ron H N; Chan, K C Allen; Maekawa, Masato; Mamotte, Cyril; Russomando, Graciela; Rousseau, François; Ahmad-Nejad, Parviz

    2017-04-01

    Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. The effect of sampling, diagnostic criteria and assessment procedures on the observed prevalence of DSM-III-R personality disorders among treated alcoholics.

    Science.gov (United States)

    Verheul, R; Hartgers, C; Van den Brink, W; Koeter, M W

    1998-03-01

    OBJECTIVE. In a recent review of empirical studies on the prevalence of DSM-III-R personality disorders among substance abusers, wide ranges of prevalence rates for overall Axis II, antisocial personality disorder (APD) and borderline personality disorder (BPD) were shown. Utilizing subsamples from within a single study population, the current report explores the effect of sampling, diagnostic criteria and assessment procedures on the observed prevalence of DSM-III-R personality disorders among treated alcoholics. Personality disorders were assessed with the Personality Diagnostic Questionnaire Revised (PDQR) at two times of measurement (Time 1 n = 459; Time 2 n = 90). In addition, APD was measured with the Composite International Diagnostic Interview (CIDI; n = 587). Finally, an unselected subgroup (n = 136) was interviewed with the International Personality Disorder Examination (IPDE). There were few differences between inpatients or outpatients or between males and females. Using the IPDE, the exclusion of substance-related pathology did not affect the prevalence estimate. However, the prevalence rates according to the PDQR varied greatly across age groups. In a representative subsample (n = 109), the prevalence rates also varied greatly across assessment methods (PDQR, 52% vs IPDE, 31%). The prevalence estimate of APD according to the CIDI was related to setting, gender, age group and the applied time-frame. These findings indicate the examined factors to be necessary qualifiers of prevalence estimates and, consequently, support the use of a multiple-criteria/multimethod assessment battery in research as well as in clinical work.

  1. Diagnostic systems in nuclear power plants. Proceedings of a technical committee meeting. Working material

    International Nuclear Information System (INIS)

    1998-01-01

    Nuclear power industry has a quite long tradition in on-line diagnostic of mechanical components and a considerable effort was put in developing diagnostic systems which are able to detect arising mechanical problems at an early stage. Computers are increasingly exploited to provide higher level information on process behaviour such as: early indication of the process deviation from normal conditions; rapid identification of the cause of any disturbance; prediction of the evolution of a disturbance; operator aid through computerized help. Following the recommendation of Several Member States to strengthen the activity in this field two divisions of IAEA established in 1995 the International Task Force on Nuclear Power Plant Diagnostics. The scope of the task force cover both technological developments and safety/licensing aspects of diagnostics. This report contains papers presented at the last in the series of Technical Committee Meetings on the Diagnostic Systems in Nuclear Power Plants organized in the framework of International Task Force

  2. Diagnostic systems in nuclear power plants. Proceedings of a technical committee meeting. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    Nuclear power industry has a quite long tradition in on-line diagnostic of mechanical components and a considerable effort was put in developing diagnostic systems which are able to detect arising mechanical problems at an early stage. Computers are increasingly exploited to provide higher level information on process behaviour such as: early indication of the process deviation from normal conditions; rapid identification of the cause of any disturbance; prediction of the evolution of a disturbance; operator aid through computerized help. Following the recommendation of Several Member States to strengthen the activity in this field two divisions of IAEA established in 1995 the International Task Force on Nuclear Power Plant Diagnostics. The scope of the task force cover both technological developments and safety/licensing aspects of diagnostics. This report contains papers presented at the last in the series of Technical Committee Meetings on the Diagnostic Systems in Nuclear Power Plants organized in the framework of International Task Force Refs, figs, tabs

  3. PVT Degradation Studies: Acoustic Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Gerges [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smith, Philip J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-01

    Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regions with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.

  4. X-ray diagnostics, X-ray therapy, diagnostics and therapy with radioactive materials in free medical practice

    International Nuclear Information System (INIS)

    Setzer, H.D.

    1976-01-01

    On the basis of the documents of the Kassenaerztliche Vereinigung Niederbayerns in Straubing, the work of the established general practicioners in the fields of X-ray and nuclear medicine was investigated for the 1st quarter of 1971, and the X-ray diagnostic services rendered were evaluated according to age and sex. 2/3 of all doctors participating in a health insurance plan in Lower Bavaria are general practitioners; all other fields are represented less often than in Munich. The values for the whole Federal Republic are in between. Internal specialists, radiologists, and urologists together carry out 85.7% of the ten examinations which contribute most to the total gonadal dose. An application of the data on the 1st quarter to the annual value is only possible by allowing for an error of 13.1%. All in all, 6% more X-ray services are administered to men than to women. For both sexes, the genetically most important group of 15-34 resp. 15-39 years of age is highly represented, although young men receive X-ray diagnostics more frequently. X-ray therapy makes up only about 0.5% of all services. Nuclear medical diagnostics is employed to the same extent by radiologists and internal specialists, while therapy with radioactive substances is almost exclusively provided by radiologists. Relative to the population density, radioactive substances are more often used in Lower Bavaria than in West Berlin. (orig.) [de

  5. Health Technology Assessment for Molecular Diagnostics: Practices, Challenges, and Recommendations from the Medical Devices and Diagnostics Special Interest Group.

    Science.gov (United States)

    Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael

    2016-01-01

    Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA

  6. Effect of Material Parameters on Steady State Creep in a Thick Composite Cylinder Subjected to Internal Pressure

    Directory of Open Access Journals (Sweden)

    Tejeet Singh

    2009-12-01

    Full Text Available The steady state creep in Al- SiCP composite cylinder subjected to internal pressure was investigated. The creep behavior of the material were described by threshold stress based creep law by assuming a stress exponent of 5. The effect of size and content of the reinforcement (SiCP , and operating temperature on the stresses and strain rates in the composite cylinder were investigated. The stresses in the cylinder did not have significant variation with varying size and content of the reinforcement, and operating temperature. However, the tangential as well as radial strain rates in the cylinder could be reduced to a significant extent by decreasing size of SiCP, increasing the content of SiCP and decreasing operating temperature.

  7. Diagnostic performance of a multiple real-time PCR assay in patients with suspected sepsis hospitalized in an internal medicine ward.

    Science.gov (United States)

    Pasqualini, Leonella; Mencacci, Antonella; Leli, Christian; Montagna, Paolo; Cardaccia, Angela; Cenci, Elio; Montecarlo, Ines; Pirro, Matteo; di Filippo, Francesco; Cistaro, Emma; Schillaci, Giuseppe; Bistoni, Francesco; Mannarino, Elmo

    2012-04-01

    Early identification of causative pathogen in sepsis patients is pivotal to improve clinical outcome. SeptiFast (SF), a commercially available system for molecular diagnosis of sepsis based on PCR, has been mostly used in patients hospitalized in hematology and intensive care units. We evaluated the diagnostic accuracy and clinical usefulness of SF, compared to blood culture (BC), in 391 patients with suspected sepsis, hospitalized in a department of internal medicine. A causative pathogen was identified in 85 patients (22%). Sixty pathogens were detected by SF and 57 by BC. No significant differences were found between the two methods in the rates of pathogen detection (P = 0.74), even after excluding 9 pathogens which were isolated by BC and were not included in the SF master list (P = 0.096). The combination of SF and BC significantly improved the diagnostic yield in comparison to BC alone (P < 0.001). Compared to BC, SF showed a significantly lower contamination rate (0 versus 19 cases; P < 0.001) with a higher specificity for pathogen identification (1.00, 95% confidence interval [CI] of 0.99 to 1.00, versus 0.94, 95% CI of 0.90 to 0.96; P = 0.005) and a higher positive predictive value (1.00, 95% CI of 1.00 to 0.92%, versus 0.75, 95% CI of 0.63 to 0.83; P = 0.005). In the subgroup of patients (n = 191) who had been receiving antibiotic treatment for ≥24 h, SF identified more pathogens (16 versus 6; P = 0.049) compared to BC. These results suggest that, in patients with suspected sepsis, hospitalized in an internal medicine ward, SF could be a highly valuable adjunct to conventional BC, particularly in patients under antibiotic treatment.

  8. Structure of diagnostics horizons and humus classification

    Directory of Open Access Journals (Sweden)

    Zanella A

    2008-03-01

    Full Text Available The classification of the main humus forms is generally based on the morpho-genetic characters of the A and OH diagnostic horizons. This is the case in the new European key of classification presented in Freiburg on September 2004 (Eurosoil Congress. Among the morpho-genetic characters, the soil structure covers a very important role. In this work, the structure of the diagnostic A and OH horizons has been analysed in terms of aggregation force, diameter and composition of the soil lumps (peds. In order to study the aggregation force, two disaggregating tools have been conceived and used. The diameter of the lumps has been measured by sieving the soil samples with standardised webs. Observing the samples thanks to a binocular magnifying 10X and 50X, the organic or/and mineral composition of the soil aggregates has been determined, data being investigated with ANOVA and Factorial Analysis. The article examines the argument from two points of view: crashing tools for estimating the soil structure (part 1 and the dimensions of the peds given in European key of humus forms classification (part 2. The categories of soil peds diameter and composition seem to be linked to the main humus forms. For instance, aggregates having a diamater larger than 1 mm and well amalgamate organo-mineral composition are more present in the A horizons of the Mull forms than in which of the other forms; contrary to the OH horizon of the Moder or Mor, the OH horizon of the Amphi forms shows an important percent of small organic lumps. Some propositions have been given in order to improve the European key of humus forms classification.

  9. Diagnostic development for current density profile control at KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J., E-mail: jinseok@nfri.re.kr [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); University of Science and Technology, Daejeon 34113 (Korea, Republic of); Chung, J. [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); Messmer, M.C.C. [Department of Applied Physics, Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-11-01

    Highlights: • The motional Stark effect (MSE) diagnostic installed at KSTAR. • Engineering challenges and solutions on the design and fabrication of the front optics housing and filter modules. • Characterization of the bandpass filters and the responses to polarized light. - Abstract: The current density profile diagnostics are critical for the control of the steady-state burning plasma operations. A multi-channel motional Stark effect (MSE) diagnostic system has been implemented for the measurements of the internal magnetic field structures that constrain the magnetic equilibrium reconstruction to accurately produce the tokamak safety factor and current density profiles for the Korea Superconducting Tokamak Advanced Research (KSTAR). This work presents the design and fabrication of the front optics and the filter modules and the calibration activities for the MSE diagnostic at KSTAR.

  10. Design advances of the Core Plasma Thomson Scattering diagnostic for ITER.

    Czech Academy of Sciences Publication Activity Database

    Scannell, R.; Maslov, M.; Naylor, G.; O’Gorman, T.; Kempenaars, M.; Carr, M.; Bílková, Petra; Böhm, Petr; Giudicotti, L.; Pasqualotto, R.; Bassan, M.; Vayakis, G.; Walsh, M.; Huxford, R.

    2017-01-01

    Roč. 12, November (2017), č. článku C11010. ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics (LAPD2017) /18./. Prague, 24.09.2017-28.09.2017] Institutional support: RVO:61389021 Keywords : Nuclear instruments and methods for hot plasma diagnostics * Plasma diagnostics - interferometry * spectroscopy and imaging Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/11/C11010/pdf

  11. Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing.

    Science.gov (United States)

    Kwon, L; Long, K D; Wan, Y; Yu, H; Cunningham, B T

    2016-01-01

    We review the recent development of mobile detection instruments used for medical diagnostics, and consider the relative advantages of approaches that utilize the internal sensing capabilities of commercially available mobile communication devices (such as smartphones and tablet computers) compared to those that utilize a custom external sensor module. In this review, we focus specifically upon mobile medical diagnostic platforms that are being developed to serve the need in global health, personalized medicine, and point-of-care diagnostics. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Expanding the Taxonomy of the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD)

    Science.gov (United States)

    Peck, Christopher C.; Goulet, Jean-Paul; Lobbezoo, Frank; Schiffman, Eric L.; Alstergren, Per; Anderson, Gary C.; de Leeuw, Reny; Jensen, Rigmor; Michelotti, Ambra; Ohrbach, Richard; Petersson, Arne; List, Thomas

    2014-01-01

    Background There is a need to expand the current temporomandibular disorder (TMD) classification to include less common, but clinically important disorders. The immediate aim was to develop a consensus-based classification system and associated diagnostic criteria that have clinical and research utility for less common TMDs. The long-term aim was to establish a foundation, vis-à-vis this classification system, that will stimulate data collection, validity testing, and further criteria refinement. Methods A working group [members of the International RDC/TMD Consortium Network of the International Association for Dental Research (IADR), members of the Orofacial Pain Special Interest Group (SIG) of the International Association for the Study of Pain (IASP), and members from other professional societies] reviewed disorders for inclusion based on clinical significance, the availability of plausible diagnostic criteria, and the ability to operationalize and study the criteria. The disorders were derived from the literature when possible and based on expert opinion as necessary. The expanded TMD taxonomy was presented for feedback at international meetings. Results Of 56 disorders considered, 37 were included in the expanded taxonomy and were placed into the following four categories: temporomandibular joint disorders, masticatory muscle disorders, headache disorders, and disorders affecting associated structures. Those excluded were extremely uncommon, lacking operationalized diagnostic criteria, not clearly related to TMDs, or not sufficiently distinct from disorders already included within the taxonomy. Conclusions The expanded TMD taxonomy offers an integrated approach to clinical diagnosis and provides a framework for further research to operationalize and test the proposed taxonomy and diagnostic criteria. PMID:24443898

  13. Bringing diagnostics to developing countries: an interview with Rosanna Peeling.

    Science.gov (United States)

    Peeling, Rosanna

    2015-01-01

    Interview with Professor Rosanna Peeling, PhD by Claire Raison (Commissioning Editor) Professor Rosanna Peeling is Chair of Diagnostic Research at the London School of Hygiene and Tropical Medicine (London, UK) and founded the International Diagnostics Centre at the institution. Professor Peeling previously worked for the WHO in Geneva, Switzerland, and continues to work on innovations for molecular diagnostics for point-of-care use in developing countries, addressing challenges posed by lack of funding and resources, regulatory issues and under-developed healthcare systems in these locations. Here, she discusses her career, recent progress in the field and how connectivity will affect global healthcare.

  14. Evaluation of internal adaptation of Class V resin composite restorations using three techniques of polymerization

    Directory of Open Access Journals (Sweden)

    José Carlos Pereira

    2007-02-01

    Full Text Available OBJECTIVE: The purpose of this in vitro study was to evaluate the internal adaptation of Class V composite restorations to the cavity walls using three different techniques of polymerization. METHODS: Standard cavities were prepared on the buccal and lingual surfaces of 24 extracted human third molars with margins located above and below the cementoenamel junction. Restorations were placed in one increment using two restorative systems: 3M Filtek A110/ Single Bond (M and 3M Filtek Z250/ Single Bond (H in the same tooth, randomly in the buccal and lingual surfaces. Resin composites were polymerized using three techniques: Group 1 - Conventional (60 s - 600 mW/cm²; Group 2 - Soft-start (20 s - 200 mW/cm² , 40 s - 600 mW/cm²; Group 3 - Pulse Activation (3 s - 200 mW/cm², 3-min hiatus, 57 s - 600 mW/cm². Buccolingual sections were polished, impressions taken and replicated. Specimens were assessed under scanning electron microscopy up to X1000 magnification. Scores were given for presence or absence of gaps (0 - no gap; 1 - gap in one wall; 2 - gap in two walls; 3 - gap in three walls. RESULTS: The mean scores of the groups were (±SD were: G1M-3.0 (± 0.0; G2M-2.43 (± 0.8; G3M- 1.71 (± 0.9; G1H- 2.14 (± 1.2; G2H- 2.00 (± 0.8; G3H- 1.67 (± 1.1. Data were analyzed using Kruskal-Wallis and Dunnet's tests. No statistically significant difference (p>0.05 was found among groups. Gaps were observed in all groups. CONCLUSIONS: The photocuring technique and the type of resin composite had no influence on the internal adaptation of the material to the cavity walls. A positive effect was observed when the slow polymerization techniques were used.

  15. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  16. [Sensitivity and specificity between the Composite International Diagnostic Interview Version 3.0 (World Mental Health, CIDI) and the Standardised Clinical Evaluation version I (SCID-I) in a mental health survey of the city of Medellin, 2012].

    Science.gov (United States)

    Montoya Gonzalez, Laura Elisa; Restrepo Bernal, Diana Patricia; Mejía-Montoya, Roberto; Bareño-Silva, José; Sierra-Hincapié, Gloria; Torres de Galvis, Yolanda; Marulanda-Restrepo, Daniel; Gómez-Sierra, Natalia; Gaviria-Arbeláez, Silvia

    2016-01-01

    In order to address the mental health problems of the Colombian population it is necessary to have diagnostic tools (local and international) that are valid, easy to apply, and comparable. To compare the sensitivity and specificity between the CIDI 3.0 and the SCID-I for major depressive disorder, bipolar I and II disorder, and substance dependence disorder. Cross-sectional study comparing the life prevalence of three mental disorders in 100 subjects using the CIDI 3.0 and the SCID-I. The study was approved by the Institutional Ethics Committee. The two diagnostic interviews were performed that measured by sensitivity, specificity, positive predictive value and negative predictive value with confidence intervals of 95%. The SPSS version 21.0 software was used for data analysis. The median age was 43.5 years, with an interquartile interval of 30 years. The highest sensitivity (Se) and specificity (Sp) was observed for drug dependence diagnosis - with 80%, (95%CI, 34.94-100), and 98.46 (95%CI, 94.7-100), respectively. SCID-I and CIDI 3.0 showed different levels of sensitivity and specificity for the three disorders studied with: high for substance dependence disorder, moderate for bipolar disorder I and II, and low for major depressive disorder. Copyright © 2015 Asociación Colombiana de Psiquiatría. All rights reserved.

  17. Air-operated valve diagnostics: requirements, programmes and experiences

    International Nuclear Information System (INIS)

    Cervilla, Remedios; Vallana, Fernando; Laporta, Jose Maria

    2014-01-01

    The aim of this paper is to present some elements in the field of air-operated valve (AOV) diagnostics from the perspective of Tecnatom, as a testing services provider in the national and international nuclear park. Throughout the following lines, we summarize the regulatory framework existing in Spain and the current practices in Spanish nuclear power plants regarding the AOV programs, the role of Tecnatom as a service provider and our testing techniques. Finally, a real test case is presented, to illustrate the value of diagnostic as predictive maintenance and early degradation detection tool. (authors)

  18. Meeting of the ITPA Topical Group on Diagnostics

    International Nuclear Information System (INIS)

    Costley, A.E.; Donne, A.J.H.

    2002-01-01

    The first meeting of the International Tokamak Physics Activities (ITPA) Topical Group (TG) on diagnostics was held at the Ioffe Physical-Technical institute, St. Petersburg, Russian Federation, on 14-16 November 2001. In total 38 participants attended the meeting and all four ITPA partners (EU, JA, RF and US) were represented. This summary covers mainly the discussions at the TG meeting. The meeting immediately followed a progress meeting, held in the same location on 12-13 November 2001, on the efforts carried out in the Russian Federation on diagnostics for ITER and burning plasma experiments

  19. Substance dependence and non-dependence in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD): can an identical conceptualization be achieved?

    Science.gov (United States)

    Saunders, John B

    2006-09-01

    This review summarizes the history of the development of diagnostic constructs that apply to repetitive substance use, and compares and contrasts the nature, psychometric performance and utility of the major diagnoses in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and International Classification of Diseases (ICD) diagnostic systems. The available literature was reviewed with a particular focus on diagnostic concepts that are relevant for clinical and epidemiological practice, and so that research questions could be generated that might inform the development of the next generation of DSM and ICD diagnoses. The substance dependence syndrome is a psychometrically robust and clinically useful construct, which applies to a range of psychoactive substances. The differences between the DSM fourth edition (DSM-IV) and the ICD tenth edition (ICD-10) versions are minimal and could be resolved. DSM-IV substance abuse performs moderately well but, being defined essentially by social criteria, may be culture-dependent. ICD-10 harmful substance use performs poorly as a diagnostic entity. There are good prospects for resolving many of the differences between the DSM and ICD systems. A new non-dependence diagnosis is required. There would also be advantages in a subthreshold diagnosis of hazardous or risky substance use being incorporated into the two systems. Biomedical research can be drawn upon to define a psychophysiological 'driving force' which could underpin a broad spectrum of substance use disorders.

  20. Results of the international Pu-2000 exercise for plutonium isotopic composition measurements

    International Nuclear Information System (INIS)

    Morel, J.; Bickel, M.; Hill, C.; Verbruggen, A.

    2004-01-01

    An international comparison for plutonium isotopic composition measurement, known as the Pu-2000 exercise, was organized by the ESARDA NDA-WG (European Safeguards Research and Development Association, Working Group on Techniques and Standards for Non-Destructive Assay). The aim of this comparison was to test X- and γ-ray spectrometry methods over a large range of isotopic ratios. These methods are based on the complex analysis of several X- and γ-rays in the KX region of the plutonium spectrum and also in the 120-700 keV energy range. The results obtained by the participants with their corresponding uncertainties are presented in this document and compared to the declared values. The main conclusions of the work are also given. No important bias due to an inadequate knowledge of the nuclear data for plutonium isotopes was observed

  1. Composite Materials

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    This book deals with the mechanical and physical behavior of composites as influenced by composite geometry. "Composite Materials" provides a comprehensive introduction for researchers and students to modern composite materials research with a special emphasis on the significance of phase geometry......, viscoelastic behavior, and internal stress states. Other physical properties considered are thermal and electrical conductivities, diffusion coefficients, dielectric constants and magnetic permeability. Special attention is given to the effect of pore shape on the mechanical and physical behavior of porous....... The book enables the reader to a better understanding of the behavior of natural composites, improvement of such materials, and design of new materials with prescribed properties. A number of examples are presented: Special composite properties considered are stiffness, shrinkage, hygro-thermal behavior...

  2. Exposure to Indian population from diagnostic radiology

    International Nuclear Information System (INIS)

    Supe, S.J.; Venkataraman, G.; Sasane, J.B.; Sawant, S.G.; Shirva, V.K.; Iyer, P.S.

    1993-01-01

    Many national and international agencies are actively engaged in taking stock of radiation safety status of radiation procedures which add to the population dose significantly. National survey is being conducted to collect data from various diagnostic X-ray institutions to assess radiation safety status and population dose arising from such practices in India. For this purpose 11 centres are collecting information on annual number of patients examined site wise and on their age and sex distribution. Patient doses are also measured for various diagnostic X-ray examinations in a few hospitals using CaSO 4 :Dy TLD dosimeters. Preliminary results of earlier study indicate that the country has about 50000 diagnostic X-ray units. The annual number of X-ray examinations is estimated to be 9x10 7 . Mean entrance skin dose for diagnostic X-rays are between 0.2 to 50 mGy depending on the type of examination. On the basis of experience gained in the earlier survey an exhaustive survey is undertaken for 1992-93 for improving the assessment of population dose. (author). 3 refs

  3. Nuclear aspects of diagnostics in RTO/RC ITER

    International Nuclear Information System (INIS)

    Walker, C.I.; Yamamoto, S.; Costley, A.; Kock, L. de; Ebisawa, K.; Janeschitz, G.; Khripunov, V.; Martin, E.; Vayakis, G.

    2000-01-01

    ITER (international thermonuclear experimental reactor) will be the first fusion device where the design of the plasma diagnostic systems will make extensive use of the materials and techniques developed in the nuclear technology field. The designs have to satisfy stringent requirements for tritium confinement, nuclear shielding and vacuum integrity. This paper introduces the requirements for diagnostics in the ITER long pulse, burning plasma environment, and addresses the impact of the reactor environment on the diagnostics and ancillary equipment. These systems necessarily require access to the plasma or first wall, which generally conflicts with the requirements of the basic machine. Holes are required through the first wall, primary shielding, containment boundaries and biological shielding. Components have a limited life and require maintenance. This paper describes the effect of the radiation environment on diagnostic design at different locations. Ex-vessel and in-vessel remote handling, hot cell refurbishment and tritium confinement are also described

  4. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  5. General review of diagnostic systems in EDF PWR units

    International Nuclear Information System (INIS)

    Chevalier, R.; Brasseur, S.; Ricard, B.

    1998-01-01

    Since the beginning of the French nuclear program, Electricite de France (EDF) has looked for ways to improve the availability and safety of its nuclear units. Therefore, monitoring systems on turbogenerators, reactor coolant pumps, primary circuits and core internal structures were designed by the Research and Development Division and implemented with technologies available during the 1970's. However, mainly because of difficulties for data interpretation by plant personnel, EDF subsequently decided to design and develop different tools to help plant operators to process a diagnosis: - a new generation of the Monitoring and Diagnostic System called PSAD, - expert systems for diagnosis on reactor coolant pumps (RCP) 'DIAPO' and turbogenerator units (TG) 'DIVA', - diagnostic guides written for most equipment pending the installation of new monitoring and diagnosis systems. The first version of PSAD, installed in five units, performs on-line monitoring of the turbogenerator shaft line, steam inlet valves, the reactor coolant pumps and the generator stator. The second version not yet implemented, will include Loose Part Detection (LPD) and Core Internal Structure Monitoring (CISM). The level of diagnosis achieved by PSAD depends on the component monitored. The TG and RCP monitoring functions of PSAD compute high level diagnosis descriptors such as natural frequencies and long term trends but do not elaborate a diagnosis automatically. However, a diagnostic assistance window is available on-line, whenever a warning message is displayed, whether for immediate or later action. The window presents a diagnostic approach whose purpose is to find the causes of the symptoms observed. This diagnosis approach is automated in the DIVA and DIAPO expert systems. Numerous potential faults can be identified for both systems thanks to a hierarchy of abnormal situations. The user interactively answers questions when information is needed to progress in the diagnosis. The resulting

  6. IMPLEMENTATION OF TURNOUTS TECHNICAL DIAGNOSTICS SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. YU. Buryak

    2015-06-01

    Full Text Available Purpose. In the paper it is necessary to: 1 find out the causes of turnouts faults to determine diagnostic features failures; 2 consider the requirements structure, purpose components of turnouts, work and technology of their maintenance to determine the construction of the economic activities related to system to the turnout’s maintenance; 3 substantiate the possibility, necessity and prospects of automated diagnostics turnout’s implementation; 4 elaborate a prototype of an automated hardware and software system for the turnouts control parameters and perform diagnostics on them. Methodology. In the paper possible turnouts faults were presented and manifestations and influence on its work were shown. According to the current technology works the process analyze of turnouts’ maintenance was conducted, were defined the basic performed operations during the examination of appearance, parameters and check the repair or replacement of parts and assemblies. Based on the analysis of reasons of turnouts malfunctioning and their fixes were systematized types of damages and ways to deal with them, an information scheme of troubleshooting were created, opportunities and limits of automating the process of diagnostics were identified and compared with the existing method of turnouts maintenance. A diagnostics system block diagram was created, an algorithm of its work was developed and established main basic principles of operation. Software and hardware to determine the turnout’s state considering diagnostic performance of points in use were applied. Findings. During the experiment was created a method of automated turnout’s diagnostics with AC electric drives, managed centrally. The results of automated hardware and software system make it possible to control turnout’s parameters and perform diagnostics on them. Originality. Authors created the method of turnout’s state determination by current curve and its spectral composition in the

  7. Thematic plan on diagnostic radiology

    International Nuclear Information System (INIS)

    2003-01-01

    Due to the vital importance of diagnostic radiology in both the diagnosis and management of disease processes, there is a need for a greater coherent international effort to help the developing nations create strategies for the incorporation of imaging into their healthcare systems. To meet the needs of such countries, a comprehensive programme is required to take into consideration the availability of local expertise (medical and technical), the infrastructure (stable electrical supply, water and air-conditioning) and the disease pattern or burden. In short, the total solution requires coordinating the International Atomic Energy Agency efforts with those of other partners. The Agency already has programmes in nuclear medicine and radiation therapy supported by activities in dosimetry and medical physics. Through the Technical Co-operation fund the Agency already supports projects in some areas of diagnostic imaging, dosimetry and radiation protection, but it lacks a comprehensive programme to provide a systematic approach focusing on the medical aspects of imaging science and including all the imaging technologies. Member States require the Agency's assistance in this area since no single UN organisation has the resources or the expertise to do the entire job without help. This document presents the proposed programme strategy and action plan

  8. International Year of Pulses 2016 | 2016 International Year of Pulses

    Science.gov (United States)

    the Year in collaboration with Governments, relevant organizations, non-governmental organizations and the composition of pulses Image 4 Wrapping up the International Year of Pulses The 5 key messages to food security Infographic Pulses and climate change International Year of Pulses 2016 The 68th UN

  9. Magnetic field measurements using the transient internal probe (TIP)

    International Nuclear Information System (INIS)

    Galambos, J.P.; Bohnet, M.A.; Jarboe, T.R.; Mattick, A.T.

    1995-01-01

    Knowledge of the internal magnetic field profile in hot plasmas is fundamental to understanding the structure and behavior of the current profile. The transient internal probe (TIP) is a novel diagnostic designed to measure internal magnetic fields in hot plasmas. The diagnostic involves shooting a magneto-optic probe through the plasma at high velocities (greater than 2 km/s) using a two stage light gas gun. Local fields are obtained by illuminating the probe with an argon ion laser and measuring the amount of Faraday rotation in the reflected beam. Initial development of the diagnostic is complete. Results of magnetic field measurements conducted at 2 km/s will be presented. Helium muzzle gas introduction to the plasma chamber has been limited to less than 0.4 Torr-ell. Magnetic field resolution of 40 Gauss and spatial resolution of 5 mm have been achieved. System frequency response is 10 MHz

  10. Teaching perceptual skills in clinical diagnostics using digital media

    NARCIS (Netherlands)

    Scheiter, Katharina; Jarodzka, Halszka

    2011-01-01

    Scheiter, K., & Jarodzka, H. (2011, May). Teaching perceptual skills in clinical diagnostics using digital media. Presentation at the 2nd International Conference “Research in Medical Education”: Shaping diamonds from bench to bedside, Universität Tübingen.

  11. Optimal Combinations of Diagnostic Tests Based on AUC.

    Science.gov (United States)

    Huang, Xin; Qin, Gengsheng; Fang, Yixin

    2011-06-01

    When several diagnostic tests are available, one can combine them to achieve better diagnostic accuracy. This article considers the optimal linear combination that maximizes the area under the receiver operating characteristic curve (AUC); the estimates of the combination's coefficients can be obtained via a nonparametric procedure. However, for estimating the AUC associated with the estimated coefficients, the apparent estimation by re-substitution is too optimistic. To adjust for the upward bias, several methods are proposed. Among them the cross-validation approach is especially advocated, and an approximated cross-validation is developed to reduce the computational cost. Furthermore, these proposed methods can be applied for variable selection to select important diagnostic tests. The proposed methods are examined through simulation studies and applications to three real examples. © 2010, The International Biometric Society.

  12. A hybrid model for combining case-control and cohort studies in systematic reviews of diagnostic tests

    Science.gov (United States)

    Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao

    2014-01-01

    Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179

  13. Limitations of typhoid fever diagnostics and the need for prevention

    NARCIS (Netherlands)

    Smits, Henk L.

    2013-01-01

    Evaluation of: Siba V, Horwood PF, Vanuga K et al. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard. Clin. Vaccine Immunol. 19(11), 1833-1837 (2012). The study under review evaluated serological tests for typhoid fever against PCR

  14. Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy Diagnostic Task Force Criteria Impact of New Task Force Criteria

    NARCIS (Netherlands)

    Cox, Moniek G. P. J.; van der Smagt, Jasper J.; Noorman, Maartje; Wiesfeld, Ans C.; Volders, Paul G. A.; van Langen, Irene M.; Atsma, Douwe E.; Dooijes, Dennis; Houweling, Arjan C.; Loh, Peter; Jordaens, Luc; Arens, Yvonne; Cramer, Maarten J.; Doevendans, Pieter A.; van Tintelen, Peter; Wilde, Arthur A. M.; Hauer, Richard N. W.

    Background-Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C) Diagnostic Task Force Criteria (TFC) proposed in 1994 are highly specific but lack sensitivity. A new international task force modified criteria to improve diagnostic yield. A comparison of diagnosis by 1994 TFC versus

  15. Probability of major depression diagnostic classification using semi-structured versus fully structured diagnostic interviews.

    Science.gov (United States)

    Levis, Brooke; Benedetti, Andrea; Riehm, Kira E; Saadat, Nazanin; Levis, Alexander W; Azar, Marleine; Rice, Danielle B; Chiovitti, Matthew J; Sanchez, Tatiana A; Cuijpers, Pim; Gilbody, Simon; Ioannidis, John P A; Kloda, Lorie A; McMillan, Dean; Patten, Scott B; Shrier, Ian; Steele, Russell J; Ziegelstein, Roy C; Akena, Dickens H; Arroll, Bruce; Ayalon, Liat; Baradaran, Hamid R; Baron, Murray; Beraldi, Anna; Bombardier, Charles H; Butterworth, Peter; Carter, Gregory; Chagas, Marcos H; Chan, Juliana C N; Cholera, Rushina; Chowdhary, Neerja; Clover, Kerrie; Conwell, Yeates; de Man-van Ginkel, Janneke M; Delgadillo, Jaime; Fann, Jesse R; Fischer, Felix H; Fischler, Benjamin; Fung, Daniel; Gelaye, Bizu; Goodyear-Smith, Felicity; Greeno, Catherine G; Hall, Brian J; Hambridge, John; Harrison, Patricia A; Hegerl, Ulrich; Hides, Leanne; Hobfoll, Stevan E; Hudson, Marie; Hyphantis, Thomas; Inagaki, Masatoshi; Ismail, Khalida; Jetté, Nathalie; Khamseh, Mohammad E; Kiely, Kim M; Lamers, Femke; Liu, Shen-Ing; Lotrakul, Manote; Loureiro, Sonia R; Löwe, Bernd; Marsh, Laura; McGuire, Anthony; Mohd Sidik, Sherina; Munhoz, Tiago N; Muramatsu, Kumiko; Osório, Flávia L; Patel, Vikram; Pence, Brian W; Persoons, Philippe; Picardi, Angelo; Rooney, Alasdair G; Santos, Iná S; Shaaban, Juwita; Sidebottom, Abbey; Simning, Adam; Stafford, Lesley; Sung, Sharon; Tan, Pei Lin Lynnette; Turner, Alyna; van der Feltz-Cornelis, Christina M; van Weert, Henk C; Vöhringer, Paul A; White, Jennifer; Whooley, Mary A; Winkley, Kirsty; Yamada, Mitsuhiko; Zhang, Yuying; Thombs, Brett D

    2018-06-01

    Different diagnostic interviews are used as reference standards for major depression classification in research. Semi-structured interviews involve clinical judgement, whereas fully structured interviews are completely scripted. The Mini International Neuropsychiatric Interview (MINI), a brief fully structured interview, is also sometimes used. It is not known whether interview method is associated with probability of major depression classification.AimsTo evaluate the association between interview method and odds of major depression classification, controlling for depressive symptom scores and participant characteristics. Data collected for an individual participant data meta-analysis of Patient Health Questionnaire-9 (PHQ-9) diagnostic accuracy were analysed and binomial generalised linear mixed models were fit. A total of 17 158 participants (2287 with major depression) from 57 primary studies were analysed. Among fully structured interviews, odds of major depression were higher for the MINI compared with the Composite International Diagnostic Interview (CIDI) (odds ratio (OR) = 2.10; 95% CI = 1.15-3.87). Compared with semi-structured interviews, fully structured interviews (MINI excluded) were non-significantly more likely to classify participants with low-level depressive symptoms (PHQ-9 scores ≤6) as having major depression (OR = 3.13; 95% CI = 0.98-10.00), similarly likely for moderate-level symptoms (PHQ-9 scores 7-15) (OR = 0.96; 95% CI = 0.56-1.66) and significantly less likely for high-level symptoms (PHQ-9 scores ≥16) (OR = 0.50; 95% CI = 0.26-0.97). The MINI may identify more people as depressed than the CIDI, and semi-structured and fully structured interviews may not be interchangeable methods, but these results should be replicated.Declaration of interestDrs Jetté and Patten declare that they received a grant, outside the submitted work, from the Hotchkiss Brain Institute, which was jointly funded by the Institute and Pfizer. Pfizer was the

  16. Bovine subclinical mastitis diagnostics, treatment and prophylaxis

    OpenAIRE

    Klimaitė, Jūratė

    2005-01-01

    The distribution of yeast fungi has been ascertained as their influence on SCM etiology. Our developed preparation for treatment for yeast and microbe caused mastitis “Gentafung” is composition of wide spectrum antibiotics and antifungal medications. An evaluation was performed of commercially available homeopathic preparations in treating SCM. A new recommended preparation “OrbeScal” was evaluated for drying cows. A comparison of Candida genus commercial identification systems diagnostic acc...

  17. Bone Composition Diagnostics: Photoacoustics Versus Ultrasound

    Science.gov (United States)

    Yang, Lifeng; Lashkari, Bahman; Mandelis, Andreas; Tan, Joel W. Y.

    2015-06-01

    Ultrasound (US) backscatter from bones depends on the mechanical properties and the microstructure of the interrogated bone. On the other hand, photoacoustics (PA) is sensitive to optical properties of tissue and can detect composition variation. Therefore, PA can provide complementary information about bone health and integrity. In this work, a comparative study of US backscattering and PA back-propagating signals from animal trabecular bones was performed. Both methods were applied using a linear frequency modulation chirp and matched filtering. A 2.2 MHz ultrasonic transducer was employed to detect both signals. The use of the frequency domain facilitates spectral analysis. The variation of signals shows that in addition to sensitivity to mineral changes, PA exhibits sensitivity to changes in the organic part of the bone. It is, therefore, concluded that the combination of both modalities can provide complementary detailed information on bone health than either method separately. In addition, comparison of PA and US depthwise images shows the higher penetration of US. Surface scan images exhibit very weak correlation between US and PA which could be caused by the different signal generation origins in mechanical versus optical properties, respectively.

  18. Hierarchical system for autonomous sensing-healing of delamination in large-scale composite structures

    International Nuclear Information System (INIS)

    Minakuchi, Shu; Sun, Denghao; Takeda, Nobuo

    2014-01-01

    This study combines our hierarchical fiber-optic-based delamination detection system with a microvascular self-healing material to develop the first autonomous sensing-healing system applicable to large-scale composite structures. In this combined system, embedded vascular modules are connected through check valves to a surface-mounted supply tube of a pressurized healing agent while fiber-optic-based sensors monitor the internal pressure of these vascular modules. When delamination occurs, the healing agent flows into the vascular modules breached by the delamination and infiltrates the damage for healing. At the same time, the pressure sensors identify the damaged modules by detecting internal pressure changes. This paper begins by describing the basic concept of the combined system and by discussing the advantages that arise from its hierarchical nature. The feasibility of the system is then confirmed through delamination infiltration tests. Finally, the hierarchical system is validated in a plate specimen by focusing on the detection and infiltration of the damage. Its self-diagnostic function is also demonstrated. (paper)

  19. Energy composition of high-energy neutral beams on the COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Mitošinková, Klára; Stöckel, Jan; Varju, Jozef; Weinzettl, Vladimír

    2016-01-01

    Roč. 61, č. 4 (2016), s. 419-423 ISSN 0029-5922. [Summer School of Plasma Diagnostics PhDiaFusion 2015: “Soft X-ray Diagnostics for Fusion Plasma”. Bezmiechowa, 16.06.2015-20.06.2015] R&D Projects: GA MŠk(CZ) LM2011021; GA MŠk(CZ) 8D15001 Institutional support: RVO:61389021 Keywords : tokamak * neutral beam injection (NBI) * Doppler effect * beam composition * beam composition Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.760, year: 2016 http://www.ichtj.waw.pl/nukleonikaa/?p=1256

  20. Development of the Model of the System of Managerial Diagnostics of the Enterprise on the Basis of Improvement of Diagnostic Purposes

    Directory of Open Access Journals (Sweden)

    Grzegorz Pawlowski

    2017-11-01

    Full Text Available The purpose of the article is to develop a model of the system of managerial diagnostics of the enterprise on the basis of the improvement of diagnostic purposes. The developed model of the system of managerial diagnostics of the enterprise is a set of subjects (owners, managers, investors, specialists, etc., objects (management system, resources, technology, methods (a set of methods and means, business indicators and criteria (parameters that, when interacting, provide the achievement (efficient and effective of the diagnostic objectives of the system of the objectives of managerial diagnostics of the enterprise, taking into account the compliance of its competitive strategy of the state of the environment function of direct action (competitors, customers, suppliers, mediators, and other contact audiences in the context of improving the efficiency and developing the management. It is determined that the system of goals of the model of the system of managerial diagnostics of the enterprise (taking into account the ensuring of the compliance of the system of management with strategic goals and tactical tasks form the following key diagnostic objectives that require improvement on the basis of business indicators (parameters, namely: 1 diagnostics of the effectiveness of controlling the internal business processes of the enterprise; 2 diagnostics of the effectiveness of the typical organizational structure of enterprise management; 3 diagnostics of the efficiency of standardization of the work of linear and functional managers and specialists at the enterprise; 4 diagnostics of the enterprise in the areas of vocational education, labor activity and motivation, innovation work and social development; 5 diagnostics of the level of conflict in the team at the enterprise; 6 diagnostics of efficiency of use of information technologies in the management of the enterprise. The prospect of further research in this area is to improve the complex system of

  1. Clinical dosimetry in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Jovanovska, A.

    2012-01-01

    Full text: Introduction: Diagnostic and interventional procedures involving x-rays are the most significant contributor to total population dose form man made sources of ionizing radiation. Purpose and aim: X-ray imaging generally covers a diverse range of examination types, many of which are increasing in frequency and technical complexity. Materials and methods: The European Directives 96/29 and 97/43 EURATOM stress the importance of accurate dosimetry and require calibration of all measuring equipment related to application of ionizing radiation in medicine. Results: The paper gives and overview of current system of dosimetry of ionizing radiations that is relevant for metrology and clinical applications. It also reflects recently achieved international harmonization in the field promoted by International Atomic Energy Agency (IAEA). Discussion: Objectives of clinical dose measurements in diagnostic and interventional radiology are multiple, as assessment of equipment performance, or assessment of risk emerging from use of ionizing radiation Conclusion: Therefore, from the clinical point of view, the requirements for dosimeters and procedures to assess dose to standard dosimetry phantoms and patients in clinical diverse modalities, as computed tomography are presented

  2. Dual-energy X-ray absorptiometry body composition in patients with secondary osteoporosis.

    Science.gov (United States)

    Messina, Carmelo; Monaco, Cristian Giuseppe; Ulivieri, Fabio Massimo; Sardanelli, Francesco; Sconfienza, Luca Maria

    2016-08-01

    Due to the tight relationship between bone and soft tissues, there has been an increased interest in body composition assessment in patients with secondary osteoporosis as well as other pathological conditions. Dual-energy X-ray absorptiometry (DXA) is primarily devoted to the evaluation of bone mineral status, but continuous scientific advances of body composition software made DXA a rapid and easily available technique to assess body composition in terms of fat mass and lean mass. As a result, the International Society for Clinical Densitometry (ISCD) recently developed Official Positions regarding the use of this technique for body composition analysis. According to ISCD paper, indications are mainly limited to three conditions: HIV patients treated with antiretroviral agents associated with a risk of lipoatrophy; obese patients undergoing treatment for high weight loss; patients with sarcopenia or muscle weakness. Nevertheless, there are several other interesting clinical applications that were not included in the ISCD position paper, such as body composition assessment in patients undergoing organ transplantation, pulmonary disease as well as all those chronic condition that may lead to malnutrition. In conclusion, DXA body composition offers new diagnostic and research possibilities for a variety of diseases; due to its high reproducibility, DXA has also the potential to monitor body composition changes with pharmacological, nutritional or physic therapeutic interventions. ISCD addressed and recommended a list of clinical condition, but the crescent availability of DXA scans and software improvements may open the use of DXA to other indication in the next future. This article provides an overview of DXA body composition indications in the management of secondary osteoporosis and other clinical indications in adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Comparison of diet consumption, body composition and lipoprotein lipid values of Kuwaiti fencing players with international norms

    Directory of Open Access Journals (Sweden)

    Hajji Salman

    2011-10-01

    Full Text Available Abstract Background No published data is currently available that describes the dietary patterns or physiological profiles of athletes participating on the Kuwaiti national fencing team and its potential impact on health and physical performance. The purpose of this investigation was to: 1 collect baseline data on nutrient intake 2 collect, analyze and report baseline for body composition, plasma lipid and lipoprotein concentrations during the competitive season, 3 compare the results with the international norms, 4 and provide necessary health and nutritional information in order to enhance the athletes' performance and skills. Methods Fifteen national-class fencers 21.5 ± 2.6 years of age participated in this study. Food intake was measured using a 3-day food record. Body composition was estimated using both the BOD POD and Body Mass Index (BMI. Total blood lipid profiles and maximum oxygen consumption was measured for each of the subjects during the competitive season. Results The results of the present study showed significant differences in dietary consumption in comparison with the recommended dietary allowances (RDA. The blood lipids profile and body composition (BMI and % body fat were in normal range in comparison with international norms However, the average VO2 max value was less than the value of the other fencers. Conclusion Due to the results of the research study, a dietary regimen can be designed that would better enhance athletic performance and minimize any health risks associated with nutrition. Percent body fat and BMI will also be categorized for all players. In addition, the plasma blood tests will help to determine if any of the players have an excessive level of lipids or any blood abnormalities. The outcomes of present study will have a direct impact on the players health and therefore their skills and athletic performance.

  4. Clinical relevance of nuclear medicine in diagnostics and therapy of the thyroid

    International Nuclear Information System (INIS)

    1982-01-01

    50 papers divided into 7 interrelated topics including the corresponding discussions are reported. The papers deal with diagnostics and therapy of thyroid diseases by means of radiopharmaceuticals. Carcinomas and functional disorders of the thyroid are discussed in the same way as problems of thyroiditis and thyroid immunology as well as morphological diagnostics of the thyroid and thyroid function related to other internal diseases

  5. Imaging and diagnostic criteria for multiple sclerosis: are we there yet?

    International Nuclear Information System (INIS)

    Josey, Lawrence; Curley, Michael; Mousavi, Foroogh Jafari; Taylor, Bruce V.; Lucas, Robyn; Coulthard, Alan

    2012-01-01

    Excluding post traumatic injury, Multiple Sclerosis (MS) is the most common disabling neurological disorder of young adults. Although the effect on mortality is limited, the association of a young demographic and significant morbidity combine to make MS a devastating disease. Since MS was given its first detailed description in 1868, diagnostic criteria continue to evolve. Recently, there has been an international commitment to combine both clinical and paraclinical tests to arrive at an earlier diagnosis. Widespread acceptance of the use of MRI in diagnosis, monitoring and research has made the role of the radiologist more critical than ever in this disease. The primary diagnostic criteria for MS are the International Panel criteria, commonly referred to as the McDonald criteria and it is essential that the radiology community is aware of the work preceding these criteria, so that they are understood in the correct context and the importance acknowledged. Literature review utilising key word search to obtain the historical and current context of magnetic resonance imaging in the diagnosis of MS. A succinct description of the evolution of criteria for the diagnosis of MS. Radiologists must recognise that there are specific diagnostic criteria for MS that continue to evolve as a result of new research, improved technology and clinical experience and it is crucial that these criteria be applied in daily practice. It should be evident that diagnostic imaging criteria for MS will be most effective when combined with standardised MRI protocols such as those published by the international Consortium of Multiple Sclerosis Centres.

  6. Transition to international classification of disease version 10, clinical modification: the impact on internal medicine and internal medicine subspecialties.

    Science.gov (United States)

    Caskey, Rachel N; Abutahoun, Angelos; Polick, Anne; Barnes, Michelle; Srivastava, Pavan; Boyd, Andrew D

    2018-05-04

    The US health care system uses diagnostic codes for billing and reimbursement as well as quality assessment and measuring clinical outcomes. The US transitioned to the International Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM) on October, 2015. Little is known about the impact of ICD-10-CM on internal medicine and medicine subspecialists. We used a state-wide data set from Illinois Medicaid specified for Internal Medicine providers and subspecialists. A total of 3191 ICD-9-CM codes were used for 51,078 patient encounters, for a total cost of US $26,022,022 for all internal medicine. We categorized all of the ICD-9-CM codes based on the complexity of mapping to ICD-10-CM as codes with complex mapping could result in billing or administrative errors during the transition. Codes found to have complex mapping and frequently used codes (n = 295) were analyzed for clinical accuracy of mapping to ICD-10-CM. Each subspecialty was analyzed for complexity of codes used and proportion of reimbursement associated with complex codes. Twenty-five percent of internal medicine codes have convoluted mapping to ICD-10-CM, which represent 22% of Illinois Medicaid patients, and 30% of reimbursements. Rheumatology and Endocrinology had the greatest proportion of visits and reimbursement associated with complex codes. We found 14.5% of ICD-9-CM codes used by internists, when mapped to ICD-10-CM, resulted in potential clinical inaccuracies. We identified that 43% of diagnostic codes evaluated and used by internists and that account for 14% of internal medicine reimbursements are associated with codes which could result in administrative errors.

  7. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  8. Diagnostic budget study of the internal variability in ensemble simulations of the Canadian RCM

    Energy Technology Data Exchange (ETDEWEB)

    Nikiema, Oumarou; Laprise, Rene [UQAM, Canadian Network for Regional Climate Modelling and Diagnostics, Centre ESCER, Departement des Sciences de la Terre et de l' Atmosphere, B.P. 8888, Montreal, QC (Canada)

    2011-06-15

    Due to the chaotic and nonlinear nature of the atmospheric dynamics, it is known that small differences in the initial conditions (IC) of models can grow and affect the simulation evolution. In this study, we perform a quantitative diagnostic budget calculation of the various diabatic and dynamical contributions to the time evolution and spatial distribution of internal variability (IV) in simulations with the nested Canadian Regional Climate Model. We establish prognostic budget equations of the IV for the potential temperature and the relative vorticity fields. For both of these variables, the IV equations present similar terms, notably terms relating to the transport of IV by ensemble-mean flow and to the covariance of fluctuations acting on the gradient of the ensemble-mean state. We show the skill of these equations to diagnose the IV that took place in an ensemble of 20 3-month (summer season) simulations that differed only in their IC. Our study suggests that the dominant terms responsible for the large increase of IV are either the covariance term involving the potential temperature fluctuations and diabatic heating fluctuations, or the covariance of inter-member fluctuations acting upon ensemble-mean gradients. Our results also show that, on average, the third-order terms are negligible, but they can become important when the IV is large. (orig.)

  9. Duplex recombinase polymerase amplification assays incorporating competitive internal controls for bacterial meningitis detection.

    Science.gov (United States)

    Higgins, Owen; Clancy, Eoin; Forrest, Matthew S; Piepenburg, Olaf; Cormican, Martin; Boo, Teck Wee; O'Sullivan, Nicola; McGuinness, Claire; Cafferty, Deirdre; Cunney, Robert; Smith, Terry J

    2018-04-01

    Recombinase polymerase amplification (RPA) is an isothermal nucleic acid amplification technology that provides rapid and robust infectious disease pathogen detection, ideal for point-of-care (POC) diagnostics in disease-prevalent low-resource countries. We have developed and evaluated three duplex RPA assays incorporating competitive internal controls for the detection of leading bacterial meningitis pathogens. Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae singleplex RPA assays were initially developed and evaluated, demonstrating 100% specificity with limits of detection of 4.1, 8.5 and 3.9 genome copies per reaction, respectively. Each assay was further developed into internally controlled duplex RPA assays via the incorporation of internal amplification control templates. Clinical performance of each internally controlled duplex RPA assay was evaluated by testing 64 archived PCR-positive clinical samples. Compared to real-time PCR, all duplex RPA assays demonstrated 100% diagnostic specificity, with diagnostic sensitivities of 100%, 86.3% and 100% for the S. pneumoniae, N. meningitidis and H. influenzae assays, respectively. This study details the first report of internally controlled duplex RPA assays for the detection of bacterial meningitis pathogens: S. pneumoniae, N. meningitidis and H. influenzae. We have successfully demonstrated the clinical diagnostic utility of each duplex RPA assay, introducing effective diagnostic technology for POC bacterial meningitis identification in disease-prevalent developing countries. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Recent developments of ECE diagnostics at JET

    Energy Technology Data Exchange (ETDEWEB)

    Luna, E. de la; Sanchez, J. [Association Euratom-Ciemat para Fusion, Ciemant (Spain); Cientoli, C.; Blanchard, P.; Joffrin, E.; Mazon, D. [Association Euratom-ENEA sulla Fusione, IFP-CNR, Milano (Italy); Riva, M.; Zerbini, M. [Association Euratom-ENEA sulla Fusione Centro Ricerche Energia Frascati (Italy); Conway, G. [IPP-Euratom Association, Garching (Germany); Felton, R.; Fessey, J.; Gowers, C. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom); Murari, A. [Consorzio RFX, Association Euratom-ENEA sulla Fusione, Padova (Italy)

    2004-07-01

    In JET, two types of ECE (electron cyclotron emission) instruments are routinely operated to provide electron temperature measurements: a Michelson interferometer and a heterodyne radiometer. ECE diagnostics are able to provide time-resolved electron temperature profiles with high spatial and temporal resolution, and have proven to play a fundamental role in the investigation and development of internal transport barriers (ITBs) in JET. In this paper we report on the major upgrade of the ECE diagnostics systems currently in progress at JET. Diagnostic developments include an upgrade of the multi-channel heterodyne radiometer, aimed at extending the radial region over which T{sub e} measurement can be performed, and the installation of a new Michelson interferometer with fast scanning capability, to improve the frequency and temporal resolution of the multi-harmonic ECE measurements at JET. Moreover, a future extension of the ECE system, an oblique ECE diagnostic to measure the ECE spectra at different angles with respect to the normal to the magnetic field, is being developed. This diagnostic is expected to give valuable insight into the interpretation of ECE measurements in high T{sub e}-plasmas and should be available for measurements once JET resumes operation in 2005.In this paper, the recent developments in the JET ECE diagnostic system will be described and illustrated with some recent results, with an emphasis on issues related with calibration stability, high-Te plasmas and ITB studies. Some of these issues will be discussed in the context of ITER.

  11. Luminescent diagnostics of skin defects in the near-infrared range

    Science.gov (United States)

    Alekseev, Yuriy V.; Rumyantseva, Valentina D.; Gorshkova, Anastasiya S.; Shchelkunova, Anastasiya E.; Shilov, Igor P.; Ivanov, Andrey V.

    2017-09-01

    Photodynamic therapy becomes a widely spread method due to cancer growth in the world. However, to detect tumors at early stages, it is necessary to carry out diagnostic measures in a timely manner. Our aim was to test the developed pharmaceutical composition, which can be used for external application in early fluorescent diagnostics even in the absence of visual changes, as well as for therapy effectiveness control. Pharmacokinetic studies on laboratory animals and volunteers were carried out. The results have shown that the dipotassium salt of Yb3+-dimethoxyhematoporphyrin IX, which is highly soluble in water and stable in storage, is a promising marker for earlier diagnostics of tumors and can be used in dermatology, dentistry, gynecology, cosmetology, ear, nose, and throat diseases, veterinary, and in other areas of medicine.

  12. Mathematics Diagnostic Testing in Engineering: An International Comparison between Ireland and Portugal

    Science.gov (United States)

    Carr, M.; Fidalgo, C.; Bigotte de Almeida, M. E.; Branco, J. R.; Santos, V.; Murphy, E.; Ní Fhloinn, E.

    2015-01-01

    Concern has been expressed throughout Europe about the significant deficiencies in the basic mathematical skills of many engineering undergraduates. Mathematics diagnostic tests in the UK, Ireland and Portugal have shown these shortcomings, which provide a challenge to those striving to introduce more innovative educational practices into…

  13. Internal anal sphincter: Clinical perspective.

    Science.gov (United States)

    Kumar, Lalit; Emmanuel, Anton

    2017-08-01

    To summarise current knowledge of Internal anal sphincter. The internal anal sphincter (IAS) is the involuntary ring of smooth muscle in the anal canal and is the major contributor to the resting pressure in the anus. Structural injury or functional weakness of the muscle results in passive incontinence of faeces and flatus. With advent of new assessment and treatment modalities IAS has become an important topic for surgeons. This review was undertaken to summarise our current knowledge of internal anal sphincter and highlight the areas that need further research. The PubMed database was used to identify relevant studies relating to internal anal sphincter. The available evidence has been summarised and advantages and limitations highlighted for the different diagnostic and therapeutic techniques. Our understanding of the physiology and pharmacology of IAS has increased greatly in the last three decades. Additionally, there has been a rise in diagnostic and therapeutic techniques specifically targeting the IAS. Although these are promising, future research is required before these can be incorporated into the management algorithm. Copyright © 2016 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  14. Effect of respiratory motion on internal radiation dosimetry

    NARCIS (Netherlands)

    Xie, Tianwu; Zaidi, Habib

    2014-01-01

    Purpose: Estimation of the radiation dose to internal organs is essential for the assessment of radiation risks and benefits to patients undergoing diagnostic and therapeutic nuclear medicine procedures including PET. Respiratory motion induces notable internal organ displacement, which influences

  15. Overview of ion source characterization diagnostics in INTF

    Science.gov (United States)

    Bandyopadhyay, M.; Sudhir, Dass; Bhuyan, M.; Soni, J.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A.

    2016-02-01

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  16. Brucella abortus choloylglycine hydrolase affects cell envelope composition and host cell internalization.

    Directory of Open Access Journals (Sweden)

    María Inés Marchesini

    Full Text Available Choloylglycine hydrolase (CGH, E.C. 3.5.1.24 is a conjugated bile salt hydrolase that catalyses the hydrolysis of the amide bond in conjugated bile acids. Bile salt hydrolases are expressed by gastrointestinal bacteria, and they presumably decrease the toxicity of host's conjugated bile salts. Brucella species are the causative agents of brucellosis, a disease affecting livestock and humans. CGH confers Brucella the ability to deconjugate and resist the antimicrobial action of bile salts, contributing to the establishment of a successful infection through the oral route in mice. Additionally, cgh-deletion mutant was also attenuated in intraperitoneally inoculated mice, which suggests that CGH may play a role during systemic infection other than hydrolyzing conjugated bile acids. To understand the role CGH plays in B. abortus virulence, we infected phagocytic and epithelial cells with a cgh-deletion mutant (Δcgh and found that it is defective in the internalization process. This defect along with the increased resistance of Δcgh to the antimicrobial action of polymyxin B, prompted an analysis of the cell envelope of this mutant. Two-dimensional electrophoretic profiles of Δcgh cell envelope-associated proteins showed an altered expression of Omp2b and different members of the Omp25/31 family. These results were confirmed by Western blot analysis with monoclonal antibodies. Altogether, the results indicate that Brucella CGH not only participates in deconjugation of bile salts but also affects overall membrane composition and host cell internalization.

  17. Exosomes - new topic in diagnostics of cancer

    International Nuclear Information System (INIS)

    Zduriencikova, M.; Gronesova, P.; Cholujova, D.; Hunakova, L.; Sedlak, J.

    2015-01-01

    Exam's, membrane vesicles with diameter in the range of 30 -100 nm, are produced by nearly all types of cells, including tumor ones. Because the molecular profile of exosomes reflects the composition of producing cells, exosomes represent the suitable source of potential bio markers for detection of malignant population. The aim of this mini review is to provide basic information about biogenesis of exosomes and some examples of their exploitation in tumor diagnostics. (author)

  18. Nuclear magnetic resonance in diagnostics of internal diseases

    International Nuclear Information System (INIS)

    Malaya, L.T.; Uvarov, N.I.; Shashura, Yu.V.; Miklyaev, I.Yu.; Zhmuro, A.V.

    1990-01-01

    Use of NMR-tomography in general and differential diagnosis of brain diseases, diseases of internal organs (liver, galbludder, pancreas, kidneys, adrenal glands, organs small pelvis, thoracic cavity, soft tissues and bone-jopint system) is shown. Physical-technical bases of getting NMR image are presented. Problems of reproducibility, accuracy and interpretation of investigation results are discussed. 253 refs.; 1 tab

  19. Electrical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Issouf Fofana

    2016-08-01

    Full Text Available The condition of the internal cellulosic paper and oil insulation are of concern for the performance of power transformers. Over the years, a number of methods have been developed to diagnose and monitor the degradation/aging of the transformer internal insulation system. Some of this degradation/aging can be assessed from electrical responses. Currently there are a variety of electrical-based diagnostic techniques available for insulation condition monitoring of power transformers. In most cases, the electrical signals being monitored are due to mechanical or electric changes caused by physical changes in resistivity, inductance or capacitance, moisture, contamination or aging by-products in the insulation. This paper presents a description of commonly used and modern electrical-based diagnostic techniques along with their interpretation schemes.

  20. Design of new Thomson scattering diagnostic system on COMPASS tokamak

    Czech Academy of Sciences Publication Activity Database

    Bílková, Petra; Aftanas, Milan; Böhm, Petr; Weinzettl, Vladimír; Šesták, David; Melich, Radek; Stöckel, Jan; Scannell, R.; Walsh, M.

    2010-01-01

    Roč. 623, č. 2 (2010), s. 656-659 ISSN 0168-9002. [International Conference on Frontiers in Diagnostic Technologies/1st./. Frascati, 25.11.2009-27.11.2009] R&D Projects: GA ČR GA202/09/1467; GA ČR GD202/08/H057 Institutional research plan: CEZ:AV0Z20430508 Keywords : Thomson scattering * Laser diagnostic * Electron temperature * Electron density Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.142, year: 2010 www.elsevier.com/locate/nima

  1. Some theoretical problems of magnetic diagnostics in tokamaks and stellarators

    International Nuclear Information System (INIS)

    Pustovitov, V.D.

    1993-12-01

    The main problem of magnetic diagnostics is discussed here: which plasma characteristics can be determined from magnetic measurements in tokamaks and stellarators. The reasons are elucidated why diamagnetic measurements are reliable and easily interpreted. We discuss also the capabilities of diagnostics based on the measurements of poloidal fields outside the plasma. This article is based on a lecture delivered at the Third International School on Plasma Physics and Controlled Fusion, held 15-22 June 1993 at St. Petersburg - Kizhi, Russia. (author)

  2. Some theoretical problems of magnetic diagnostics in tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Pustovitov, V.D.

    1993-12-01

    The main problem of magnetic diagnostics is discussed here: which plasma characteristics can be determined from magnetic measurements in tokamaks and stellarators. The reasons are elucidated why diamagnetic measurements are reliable and easily interpreted. We discuss also the capabilities of diagnostics based on the measurements of poloidal fields outside the plasma. This article is based on a lecture delivered at the Third International School on Plasma Physics and Controlled Fusion, held 15-22 June 1993 at St. Petersburg - Kizhi, Russia. (author).

  3. Partial verification bias and incorporation bias affected accuracy estimates of diagnostic studies for biomarkers that were part of an existing composite gold standard.

    Science.gov (United States)

    Karch, Annika; Koch, Armin; Zapf, Antonia; Zerr, Inga; Karch, André

    2016-10-01

    To investigate how choice of gold standard biases estimates of sensitivity and specificity in studies reassessing the diagnostic accuracy of biomarkers that are already part of a lifetime composite gold standard (CGS). We performed a simulation study based on the real-life example of the biomarker "protein 14-3-3" used for diagnosing Creutzfeldt-Jakob disease. Three different types of gold standard were compared: perfect gold standard "autopsy" (available in a small fraction only; prone to partial verification bias), lifetime CGS (including the biomarker under investigation; prone to incorporation bias), and "best available" gold standard (autopsy if available, otherwise CGS). Sensitivity was unbiased when comparing 14-3-3 with autopsy but overestimated when using CGS or "best available" gold standard. Specificity of 14-3-3 was underestimated in scenarios comparing 14-3-3 with autopsy (up to 24%). In contrast, overestimation (up to 20%) was observed for specificity compared with CGS; this could be reduced to 0-10% when using the "best available" gold standard. Choice of gold standard affects considerably estimates of diagnostic accuracy. Using the "best available" gold standard (autopsy where available, otherwise CGS) leads to valid estimates of specificity, whereas sensitivity is estimated best when tested against autopsy alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. SALIVA AS A DIAGNOSTIC FLUID

    Directory of Open Access Journals (Sweden)

    Pezelj-Ribarić Sonja

    2015-12-01

    Full Text Available Saliva is a readily available oral fluid with many functions, from digestion, maintenance of oral tissues' integrity, to caries prevention. Changes regarding its secretion may be divided into qualitative and quantitative: both of them are a consequence of certain conditions/diseases (e.g. internal factors or nutrients/drugs ingested (e.g. external factors. During the last 15 years, technological advances gave a significant momentum to utilization of saliva as a diagnostic tool. Analysis of saliva, just like the blood analysis, has two main objectives: to identify the subjects suffering from a certain disorder, and to follow the development and progress of therapy. This paper provides an overview of possibilities for the use of saliva for diagnostic purposes and gives specific examples of some clinical investigations, with the final aim to stimulate the use of this noninvasive means for the health care promotion.

  5. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D.

    Science.gov (United States)

    Chen, J; Ding, W X; Brower, D L; Finkenthal, D; Muscatello, C; Taussig, D; Boivin, R

    2016-11-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  6. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

    International Nuclear Information System (INIS)

    Chen, J.; Ding, W. X.; Brower, D. L.; Finkenthal, D.; Muscatello, C.; Taussig, D.; Boivin, R.

    2016-01-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  7. Changes in IEC standards related to diagnostic radiology

    International Nuclear Information System (INIS)

    Porubszky, T.; Barsai, J.

    2007-01-01

    Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.

  8. 4TH International Conference on High-Temperature Ceramic Matrix Composites

    National Research Council Canada - National Science Library

    2001-01-01

    .... Topic to be covered include fibers, interfaces, interphases, non-oxide ceramic matrix composites, oxide/oxide ceramic matrix composites, coatings, and applications of high-temperature ceramic matrix...

  9. Composite particles and symplectic (Semi-) groups

    International Nuclear Information System (INIS)

    Kramer, P.

    1978-01-01

    Nuclear composits particle dynamics is intimately related to the fermion character of nucleons. This property is implemented via the permutational structure of nuclear states, leading to the concept of exchange and to the quantum number of the orbital partition. We review Weyl operators and representations of linear canonical transformations in Bargmann Hilbert space. In section 4 we use canonical transformations to describe the general n-body dynamics. In section 5 we derive the composite particle dynamics and discuss an algorithm to obtain the interaction of composite particles whose constituents are assumed to be in harmonic oscillator states. As a first example we treat in section 6 composite particles with unexcited internal oscillator states. In section 7 we deal with composite particles of internal oscillator shell configurations. (orig.) [de

  10. Medical Physics Staffing Needs in Diagnostic Imaging and Radionuclide Therapy: An Activity Based Approach [Endorsed by International Organization for Medical Physics

    International Nuclear Information System (INIS)

    2018-01-01

    Over the last decades, the rapid technological development of diagnostic and interventional radiology and nuclear medicine has made them major tools of modern medicine. However, at the same time the involved risks, the growing number of procedures and the increasing complexity of the procedures require competent professional staff to ensure safe and effective patient diagnosis, treatment and management. Medical physicists (or clinically qualified medical physicists) have been recognized as vital health professionals with important and clear responsibilities related to quality and safety of applications of ionizing radiation in medicine. This publication describes an algorithm developed to determine the recommended staffing levels for clinical medical physics services in medical imaging and radionuclide therapy, based on current best practice, as described in international guidelines.

  11. Evolution of diagnostic criteria and assessments for Parkinson's disease mild cognitive impairment.

    Science.gov (United States)

    Goldman, Jennifer G; Holden, Samantha K; Litvan, Irene; McKeith, Ian; Stebbins, Glenn T; Taylor, John-Paul

    2018-04-01

    Mild cognitive impairment has gained recognition as a construct and a potential prodromal stage to dementia in both Alzheimer's disease and Parkinson's disease (PD). Although mild cognitive impairment has been recognized in the Alzheimer's disease field, it is a relatively more recent topic of interest in PD. Recent advances include the development of diagnostic criteria for PD mild cognitive impairment to provide more uniform definitions for clinical and research use. Studies reveal that mild cognitive impairment in PD is frequent, but also heterogeneous, with variable clinical presentations, differences in its progression to dementia, and likely differences in underlying pathophysiology. Application of the International Parkinson and Movement Disorder Society PD Mild Cognitive Impairment Task Force diagnostic criteria has provided insights regarding cognitive measures, functional assessments, and other key topics that may require additional refinement. Furthermore, it is important to consider definitions of PD mild cognitive impairment in the landscape of other related Lewy body disorders, such as dementia with Lewy bodies, and in the context of prodromal and early-stage PD. This article examines the evolution of mild cognitive impairment in concept and definition, particularly in PD, but also in related disorders such as Alzheimer's disease and dementia with Lewy bodies; the development and application of International Parkinson and Movement Disorder Society PD Mild Cognitive Impairment diagnostic criteria; and insights and future directions for the field of PD mild cognitive impairment. © 2018 International Parkinson and Movement Disorder Society. © 2018 International Parkinson and Movement Disorder Society.

  12. PEGylation of Phytantriol-Based Lyotropic Liquid Crystalline Particles-The Effect of Lipid Composition, PEG Chain Length, and Temperature on the Internal Nanostructure

    DEFF Research Database (Denmark)

    Nilsson, Christa; Ostergaard, Jesper; Larsen, Susan Weng

    2014-01-01

    of these lipidic nonlamellar liquid crystalline particles by using DSPE-mPEGs with three different block lengths of the hydrophilic PEG segment. The effects of lipid composition, PEG chain length, and temperature on the morphology and internal nanostructure of these self-assembled lipidic aqueous dispersions based...

  13. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  14. A clinical audit programme for diagnostic radiology: The Approach adopted by the international atomic energy agency

    International Nuclear Information System (INIS)

    Faulkner, K.; Jaervinen, H.; Butler, P.; McLean, I. D.; Pentecost, M.; Rickard, M.; Abdullah, B.

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  15. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency.

    Science.gov (United States)

    Faulkner, K; Järvinen, H; Butler, P; McLean, I D; Pentecost, M; Rickard, M; Abdullah, B

    2010-01-01

    The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to

  16. Tomographic capabilities of the new GEM based SXR diagnostic of WEST

    Czech Academy of Sciences Publication Activity Database

    Jardin, A.; Mazon, D.; O’Mullane, M.; Mlynář, Jan; Löffelmann, Viktor; Imríšek, Martin; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.

    2016-01-01

    Roč. 11, July (2016), č. článku C07006. ISSN 1748-0221. [International Conference Frontiers in Diagnostics fix Technologies (ICFDT4). Frascati (Rome), 30.03.2016-01.04.2016] Institutional support: RVO:61389021 Keywords : GEM * SXR * tomography * plasma diagnostics Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/11/07/C07006/pdf

  17. International conference on composite materials and energy: Proceedings. Enercomp 95

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    World demand for composite materials is continuously increasing. High strength and rigidity, associated with light weight, are the key factors for composites' success. These materials find numerous applications in all sectors of industry. Presently, a sector of particular interest in terms of demand for composite materials is the energy industry. More and more applications are found in the field of the forms of energy: electrical, petroleum, gas, nuclear, solar and wind. The topics addressed in various sessions of the conference cover potential applications of the entire range of polymer, metal and ceramic composites in all sectors of energy. Papers are divided into sessions covering the following topics: properties; design and analysis; fracture; fatigue and long-term performance; new materials; innovative processing; liquid molding; joining and repairs; radiation curing; recycling; development in ceramic materials; innovations in metallic materials; metal-matrix composites; nondestructive evaluation; energy savings in transportation; pressure vessels and piping; wind energy applications; electrical components; concrete applications; power plant applications; and new materials in the energy field. Most of the papers have been processed separately for inclusion on the data base

  18. Braided reinforced composite rods for the internal reinforcement of concrete

    Science.gov (United States)

    Gonilho Pereira, C.; Fangueiro, R.; Jalali, S.; Araujo, M.; Marques, P.

    2008-05-01

    This paper reports on the development of braided reinforced composite rods as a substitute for the steel reinforcement in concrete. The research work aims at understanding the mechanical behaviour of core-reinforced braided fabrics and braided reinforced composite rods, namely concerning the influence of the braiding angle, the type of core reinforcement fibre, and preloading and postloading conditions. The core-reinforced braided fabrics were made from polyester fibres for producing braided structures, and E-glass, carbon, HT polyethylene, and sisal fibres were used for the core reinforcement. The braided reinforced composite rods were obtained by impregnating the core-reinforced braided fabric with a vinyl ester resin. The preloading of the core-reinforced braided fabrics and the postloading of the braided reinforced composite rods were performed in three and two stages, respectively. The results of tensile tests carried out on different samples of core-reinforced braided fabrics are presented and discussed. The tensile and bending properties of the braided reinforced composite rods have been evaluated, and the results obtained are presented, discussed, and compared with those of conventional materials, such as steel.

  19. Diagnostics of mobile dust in scrape-off layer plasmas

    International Nuclear Information System (INIS)

    Ratynskaia, S; Castaldo, C; Bergsaaker, H; Rudakov, D

    2011-01-01

    Dust production and accumulation pose serious safety and operational implications for the next generation fusion devices. Mobile dust particles can result in core plasma contamination with impurities, and those with high velocities can significantly contribute to the wall erosion. Diagnostics for monitoring dust in tokamaks during plasma discharges are hence important as they can provide information on dust velocity and size, and-in some cases-on dust composition. Such measurements are also valuable as an input for theoretical models of dust dynamics in scrape-off layer plasmas. Existing in situ dust diagnostics, focusing on the range of dust parameters they can detect, are reviewed. Particular attention is paid to the diagnostics which allow us to detect tails of the dust velocity and size distributions, e.g. small and very fast particles. Some of the techniques discussed have been adopted from space-related research and have been shown to be feasible and useful for tokamak applications as well.

  20. Charge Aspects of Composite Pair Superconductivity

    Science.gov (United States)

    Flint, Rebecca

    2014-03-01

    Conventional Cooper pairs form from well-defined electronic quasiparticles, making the internal structure of the pair irrelevant. However, in the 115 family of superconductors, the heavy electrons are forming as they pair and the internal pair structure becomes as important as the pairing mechanism. Conventional spin fluctuation mediated pairing cannot capture the direct transition from incoherent local moments to heavy fermion superconductivity, but the formation of composite pairs favored by the two channel Kondo effect can. These composite pairs are local d-wave pairs formed by two conduction electrons in orthogonal Kondo channels screening the same local moment. Composite pairing shares the same symmetries as magnetically mediated pairing, however, only composite pairing necessarily involves a redistribution of charge within the unit cell originating from the internal pair structure, both as a monopole (valence change) and a quadrupole effect. This redistribution will onset sharply at the superconducting transition temperature. A smoking gun test for composite pairing is therefore a sharp signature at Tc - for example, a cusp in the Mossbauer isomer shift in NpPd5Al2 or in the NQR shift in (Ce,Pu)CoIn5.

  1. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  2. Diagnostics, therapy and ecology of thyroid diseases

    International Nuclear Information System (INIS)

    Stieve, F.E.; Roedler, H.D.

    1983-01-01

    Topical problems concerning diagnostics, therapy and ecology of thyroid diseases were discussed on an international level at this symposium. As the problems are mostly medical in nature, the symposium started with papers on the anatomy, physiology, and pathology of the thyroid, followed by lectures on dose calculation and dose/effect relationships. Particular attention is paid to the distinction between external radiation exposure and incorporation of radioactive materials, especially iodine. Another section of the symposium was dedicated to the establishment of radiation hazards. The symposium ended with a discussion of the value of diagnostic and therapeutical procedures. The extensive discussions between experts from different nations and different fields of science have surely helped to deepen the knowledge on radiation effects. (orig./MG) [de

  3. Converging Human and Malaria Vector Diagnostics with Data Management towards an Integrated Holistic One Health Approach

    Directory of Open Access Journals (Sweden)

    Konstantinos Mitsakakis

    2018-02-01

    Full Text Available Monitoring malaria prevalence in humans, as well as vector populations, for the presence of Plasmodium, is an integral component of effective malaria control, and eventually, elimination. In the field of human diagnostics, a major challenge is the ability to define, precisely, the causative agent of fever, thereby differentiating among several candidate (also non-malaria febrile diseases. This requires genetic-based pathogen identification and multiplexed analysis, which, in combination, are hardly provided by the current gold standard diagnostic tools. In the field of vectors, an essential component of control programs is the detection of Plasmodium species within its mosquito vectors, particularly in the salivary glands, where the infective sporozoites reside. In addition, the identification of species composition and insecticide resistance alleles within vector populations is a primary task in routine monitoring activities, aiming to support control efforts. In this context, the use of converging diagnostics is highly desirable for providing comprehensive information, including differential fever diagnosis in humans, and mosquito species composition, infection status, and resistance to insecticides of vectors. Nevertheless, the two fields of human diagnostics and vector control are rarely combined, both at the diagnostic and at the data management end, resulting in fragmented data and mis- or non-communication between various stakeholders. To this direction, molecular technologies, their integration in automated platforms, and the co-assessment of data from multiple diagnostic sources through information and communication technologies are possible pathways towards a unified human vector approach.

  4. Converging Human and Malaria Vector Diagnostics with Data Management towards an Integrated Holistic One Health Approach.

    Science.gov (United States)

    Mitsakakis, Konstantinos; Hin, Sebastian; Müller, Pie; Wipf, Nadja; Thomsen, Edward; Coleman, Michael; Zengerle, Roland; Vontas, John; Mavridis, Konstantinos

    2018-02-03

    Monitoring malaria prevalence in humans, as well as vector populations, for the presence of Plasmodium , is an integral component of effective malaria control, and eventually, elimination. In the field of human diagnostics, a major challenge is the ability to define, precisely, the causative agent of fever, thereby differentiating among several candidate (also non-malaria) febrile diseases. This requires genetic-based pathogen identification and multiplexed analysis, which, in combination, are hardly provided by the current gold standard diagnostic tools. In the field of vectors, an essential component of control programs is the detection of Plasmodium species within its mosquito vectors, particularly in the salivary glands, where the infective sporozoites reside. In addition, the identification of species composition and insecticide resistance alleles within vector populations is a primary task in routine monitoring activities, aiming to support control efforts. In this context, the use of converging diagnostics is highly desirable for providing comprehensive information, including differential fever diagnosis in humans, and mosquito species composition, infection status, and resistance to insecticides of vectors. Nevertheless, the two fields of human diagnostics and vector control are rarely combined, both at the diagnostic and at the data management end, resulting in fragmented data and mis- or non-communication between various stakeholders. To this direction, molecular technologies, their integration in automated platforms, and the co-assessment of data from multiple diagnostic sources through information and communication technologies are possible pathways towards a unified human vector approach.

  5. Converging Human and Malaria Vector Diagnostics with Data Management towards an Integrated Holistic One Health Approach

    Science.gov (United States)

    Mitsakakis, Konstantinos; Hin, Sebastian; Wipf, Nadja; Coleman, Michael; Zengerle, Roland; Vontas, John; Mavridis, Konstantinos

    2018-01-01

    Monitoring malaria prevalence in humans, as well as vector populations, for the presence of Plasmodium, is an integral component of effective malaria control, and eventually, elimination. In the field of human diagnostics, a major challenge is the ability to define, precisely, the causative agent of fever, thereby differentiating among several candidate (also non-malaria) febrile diseases. This requires genetic-based pathogen identification and multiplexed analysis, which, in combination, are hardly provided by the current gold standard diagnostic tools. In the field of vectors, an essential component of control programs is the detection of Plasmodium species within its mosquito vectors, particularly in the salivary glands, where the infective sporozoites reside. In addition, the identification of species composition and insecticide resistance alleles within vector populations is a primary task in routine monitoring activities, aiming to support control efforts. In this context, the use of converging diagnostics is highly desirable for providing comprehensive information, including differential fever diagnosis in humans, and mosquito species composition, infection status, and resistance to insecticides of vectors. Nevertheless, the two fields of human diagnostics and vector control are rarely combined, both at the diagnostic and at the data management end, resulting in fragmented data and mis- or non-communication between various stakeholders. To this direction, molecular technologies, their integration in automated platforms, and the co-assessment of data from multiple diagnostic sources through information and communication technologies are possible pathways towards a unified human vector approach. PMID:29401670

  6. Sintering of composite

    International Nuclear Information System (INIS)

    Bordia, R.K.; Scherer, G.W.

    1988-01-01

    Several constitutive laws have been used in the literature to predict the response of sintering bodies under external and internal stress fields. These analyses are based on the assumptions of linear and isotropic behavior. The authors provide a critical examination of these equations and show that some of the available constitutive laws predict a negative Poisson's ratio. These laws have been used to analyze sintering of ceramic matrix composites with rigid inclusions and predict large values of the internal stresses and significant retardation of the densification of composites. Since a negative value of Poisson's ratio has never been observed in sinter - forging experiments, the authors conclude that either the stresses are small (as predicted by the constitutive laws with positive Poisson's ratio) or the basic assumption of linearity and isotropy used in all the analyses is incorrect. Finally, the authors discuss some phenomena that could be important in understanding the densification of ceramic matrix composites

  7. Influence diagnostics in meta-regression model.

    Science.gov (United States)

    Shi, Lei; Zuo, ShanShan; Yu, Dalei; Zhou, Xiaohua

    2017-09-01

    This paper studies the influence diagnostics in meta-regression model including case deletion diagnostic and local influence analysis. We derive the subset deletion formulae for the estimation of regression coefficient and heterogeneity variance and obtain the corresponding influence measures. The DerSimonian and Laird estimation and maximum likelihood estimation methods in meta-regression are considered, respectively, to derive the results. Internal and external residual and leverage measure are defined. The local influence analysis based on case-weights perturbation scheme, responses perturbation scheme, covariate perturbation scheme, and within-variance perturbation scheme are explored. We introduce a method by simultaneous perturbing responses, covariate, and within-variance to obtain the local influence measure, which has an advantage of capable to compare the influence magnitude of influential studies from different perturbations. An example is used to illustrate the proposed methodology. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Predictors of Inappropriate Use of Diagnostic Tests and Management of Bronchiolitis

    Science.gov (United States)

    Sarmiento, Lorena; Rojas-Soto, Gladys E.

    2017-01-01

    Background The aim of the present study was to determine predictors of inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. Methods In an analytical cross-sectional study, we determined independent predictors of the inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. We defined a composite outcome score as the main outcome variable. Results Of the 303 included patients, 216 (71.3%) experienced an inappropriate use of diagnostic tests and treatment of bronchiolitis. After controlling for potential confounders, it was found that atopic dermatitis (OR 5.30; CI 95% 1.14–24.79; p = 0.034), length of hospital stay (OR 1.48; CI 95% 1.08–2.03; p = 0.015), and the number of siblings (OR 1.92; CI 95% 1.13–3.26; p = 0.015) were independent predictors of an inappropriate use of diagnostic tests and treatment of the disease. Conclusions Inappropriate use of diagnostic tests and treatment of bronchiolitis was a highly prevalent outcome in our population of study. Participants with atopic dermatitis, a longer hospital stay, and a greater number of siblings were at increased risk for inappropriate use of diagnostic tests and management of the disease. PMID:28758127

  9. Correcting biases in psychiatric diagnostic practice in Northwest Russia: Comparing the impact of a general educational program and a specific diagnostic training program

    Directory of Open Access Journals (Sweden)

    Rezvyy Grigory

    2008-04-01

    Full Text Available Abstract Background A general education in psychiatry does not necessary lead to good diagnostic skills. Specific training programs in diagnostic coding are established to facilitate implementation of ICD-10 coding practices. However, studies comparing the impact of these two different educational approaches on diagnostic skills are lacking. The aim of the current study was to find out if a specific training program in diagnostic coding improves the diagnostic skills better than a general education program, and if a national bias in diagnostic patterns can be minimised by a specific training in diagnostic coding. Methods A pre post design study with two groups was carried in the county of Archangels, Russia. The control group (39 psychiatrists took the required course (general educational program, while the intervention group (45 psychiatrists were given a specific training in diagnostic coding. Their diagnostic skills before and after education were assessed using 12 written case-vignettes selected from the entire spectrum of psychiatric disorders. Results There was a significant improvement in diagnostic skills in both the intervention group and the control group. However, the intervention group improved significantly more than did the control group. The national bias was partly corrected in the intervention group but not to the same degree in the control group. When analyzing both groups together, among the background factors only the current working place impacted the outcome of the intervention. Conclusion Establishing an internationally accepted diagnosis seems to be a special skill that requires specific training and needs to be an explicit part of the professional educational activities of psychiatrists. It does not appear that that skill is honed without specific training. The issue of national diagnostic biases should be taken into account in comparative cross-cultural studies of almost any character. The mechanisms of such biases are

  10. ECE diagnostics for RTO/RC ITER

    International Nuclear Information System (INIS)

    Vayakis, G.; Bartlett, D.V.; Costley, A.E.

    2001-01-01

    This paper presents the current status of the Electron Cyclotron Emission (ECE) diagnostic on the Reduced Technical Objectives/Reduced Cost International Thermonuclear Experimental Reactor (RTO/RC ITER). It discusses the implications of the new machine design on the measurement requirements, the ability of the diagnostic technique to meet these, and the changes in the implementation imposed by the new layout. Finally, it outlines the physics studies, design and R and D work required prior to the detailed design and construction of the diagnostic. Key results are: (i) that the localisation of the measurement is similar to that in ITER-FDR (40-100 mm in X-mode, 60-200 mm in O-mode for the reference scenario), so that the relative spatial resolution degrades in this, smaller, machine, and (ii) the expected effect of transport barriers on the temperature profile in the high temperature region will be poorly resolved, because the effect of the temperature gradient on the outboard side is to degrade the resolution to (∼250 mm in X-mode, ∼350 mm in O-mode). Nevertheless ECE will be able to make a unique and useful contribution to the RTO/RC ITER measurement set

  11. Test of 1D carbon-carbon composite prototype tiles for the SPIDER diagnostic calorimeter

    Science.gov (United States)

    Serianni, G.; Pimazzoni, A.; Canton, A.; Palma, M. Dalla; Delogu, R.; Fasolo, D.; Franchin, L.; Pasqualotto, R.; Tollin, M.

    2017-08-01

    Additional heating will be provided to the thermonuclear fusion experiment ITER by injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction at Consorzio RFX in Padova (Italy), the production of negative ions will be studied and optimised. To this purpose the STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) diagnostic will be used to characterise the SPIDER beam during short operation (several seconds) and to verify if the beam meets the ITER requirement regarding the maximum allowed beam non-uniformity (below ±10%). The most important measurements performed by STRIKE are beam uniformity, beamlet divergence and stripping losses. The major components of STRIKE are 16 1D-CFC (Carbon matrix-Carbon Fibre reinforced Composite) tiles, observed at the rear side by a thermal camera. The requirements of the 1D CFC material include a large thermal conductivity along the tile thickness (at least 10 times larger than in the other directions); low specific heat and density; uniform parameters over the tile surface; capability to withstand localised heat loads resulting in steep temperature gradients. So 1D CFC is a very anisotropic and delicate material, not commercially available, and prototypes are being specifically realised. This contribution gives an overview of the tests performed on the CFC prototype tiles, aimed at verifying their thermal behaviour. The spatial uniformity of the parameters and the ratio between the thermal conductivities are assessed by means of a power laser at Consorzio RFX. Dedicated linear and non-linear simulations are carried out to interpret the experiments and to estimate the thermal conductivities; these simulations are described and a comparison of the experimental data with the simulation results is presented.

  12. SPECIFICITY OF MANIFACTURING PROCESS VALIDATION FOR DIAGNOSTIC SEROLOGICAL DEVICES

    Directory of Open Access Journals (Sweden)

    O. Yu. Galkin

    2018-02-01

    Full Text Available The aim of this research was to analyze recent scientific literature, as well as national and international legislature on manifacturing process validation of biopharmaceutical production, in particular devices for serological diagnostics. Technology validation in the field of medical devices for serological diagnostics is most influenced by the Technical Regulation for Medical Devices for in vitro Diagnostics State Standards of Ukraine – SSU EN ISO 13485:2015 “Medical devices. Quality management system. Requirements for regulation”, SSU EN ISO 14971:2015 “Medical devices. Instructions for risk management”, Instruction ST-N of the Ministry of Healthcare of Ukraine 42-4.0:2014 “Medications. Suitable industrial practice”, State Pharmacopoeia of Ukraine and Instruction ICH Q9 on risk management. Current recommendations for validations of drugs manufacturing process, including biotechnological manufacturing, can not be directly applied to medical devices for in vitro diagnostics. It was shown that the specifics of application and raw materials require individual validation parameters and process validations for serological diagnostics devices. Critical parameters to consider in validation plans were provided for every typical stage of production of in vitro diagnostics devices on the example of immunoassay kits, such as obtaining protein antigens, including recombinant ones, preparations of mono- and polyclonal antibodies, immunoenzyme conjugates and immunosorbents, chemical reagents etc. The bottlenecks of technologies for in vitro diagnostics devices were analyzed from the bioethical and biosafety points of view.

  13. Alcohol Use Disorders in Argentinian Girls and Women 12 Months Before Delivery: Comparison of DSM-IV, DSM-5, and ICD-10 Diagnostic Criteria.

    Science.gov (United States)

    López, Mariana B; Conde, Karina; Cremonte, Mariana

    The evidence of important problems related to prenatal alcohol exposure has faced researchers with the problem of understanding and screening alcohol use in this population. Although any alcohol use should be considered risky during pregnancy, identifying alcohol-drinking problems (ADPs) could be especially important because women with ADPs could not benefit from a simple advice of abstinence and because their offsprings are subjected to a higher risk of problems related with prenatal alcohol exposure. In this context, we aim to study the prevalence and characteristics of ADPs in pregnant women, evaluating the performance of different diagnostic systems in this population. The aims of the study were to describe the prevalence of ADPs obtained with the criteria of the Diagnostic and Statistical Manual of Mental Disorders in its fourth (DSM-IV) and fifth edition (DSM-5), and the International Classification of Diseases (ICD)-10, in Argentinean females aged 13 to 44 years, 12 months before delivery; to evaluate the level of agreement between these classification systems; and to analyze the performance of each diagnosis criterion in this population. Data were collected through personal interviews of a probability sample of puerperal women (N = 641) in the city of Santa Fe (Argentina), between October 2010 and February 2011. Diagnoses compatible with DSM-IV, DSM-5, and ICD-10 were obtained through the Composite International Diagnostic Interview. Agreement among diagnostic systems was measured through Cohen kappa. Diagnosis criteria performance were analyzed considering their prevalence and discriminating ability (D value). Total ADP prevalence was 6.4% for DSM-IV (4.2% abuse and 2.2% dependence), 8.1% for DSM-5 (6.4% mild, 0.8% moderate, and 0.9% severe alcohol use disorder), and 14.1% for the ICD-10 (11.9% harmful use and 2.2% dependence). DSM-5 modifications improved agreement between DSM and ICD. The least prevalent and worst discriminating ability diagnostic

  14. Simulated plasma facing component measurements for an in situ surface diagnostic on Alcator C-Moda)

    Science.gov (United States)

    Hartwig, Z. S.; Whyte, D. G.

    2010-10-01

    The ideal in situ plasma facing component (PFC) diagnostic for magnetic fusion devices would perform surface element and isotope composition measurements on a shot-to-shot (˜10 min) time scale with ˜1 μm depth and ˜1 cm spatial resolution over large areas of PFCs. To this end, the experimental adaptation of the customary laboratory surface diagnostic—nuclear scattering of MeV ions—to the Alcator C-Mod tokamak is being guided by ACRONYM, a Geant4 synthetic diagnostic. The diagnostic technique and ACRONYM are described, and synthetic measurements of film thickness for boron-coated PFCs are presented.

  15. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    Science.gov (United States)

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  16. Nuclear reaction data for IBA applications to cultural heritage diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Maino, G.; Menapace, E. [Bologna Univ., ENEA (Italy)

    2008-07-01

    Main aspects are discussed concerning nuclear reaction cross-sections for PIXE and PIGE (Particle Induced Gamma-ray Emission) analyses, especially referring to cultural heritage diagnostics, within the framework of ion beam analysis (IBA) methods, also reviewing recent results from international Conferences on Nuclear Data for Science and Technology and from NEANSC meetings and IAEA initiatives on the matter.To sum up this work, it is then worth remarking the following items: IBA techniques are powerful tools to derive unique information as for corrosion, degradation and, generally, conservation conditions of materials. Careful analyses of specific systems require accurate evaluations and establishment of complete databases, in particular for stopping powers and relevant cross sections. The physical parameters to be accurately determined are, therefore, nuclear reaction cross sections of importance for NRA analysis of light elements and stopping powers and ranges of light and heavy ions in various matrices. Light elements (H, Li, B, C, N, O, etc.) play an important role as constituents of many important organic as well inorganic materials in historical and artistic objects. To a large extent these materials occur in the near-surface area of a material with altered or degraded composition.

  17. Nuclear reaction data for IBA applications to cultural heritage diagnostics

    International Nuclear Information System (INIS)

    Maino, G.; Menapace, E.

    2008-01-01

    Main aspects are discussed concerning nuclear reaction cross-sections for PIXE and PIGE (Particle Induced Gamma-ray Emission) analyses, especially referring to cultural heritage diagnostics, within the framework of ion beam analysis (IBA) methods, also reviewing recent results from international Conferences on Nuclear Data for Science and Technology and from NEANSC meetings and IAEA initiatives on the matter.To sum up this work, it is then worth remarking the following items: IBA techniques are powerful tools to derive unique information as for corrosion, degradation and, generally, conservation conditions of materials. Careful analyses of specific systems require accurate evaluations and establishment of complete databases, in particular for stopping powers and relevant cross sections. The physical parameters to be accurately determined are, therefore, nuclear reaction cross sections of importance for NRA analysis of light elements and stopping powers and ranges of light and heavy ions in various matrices. Light elements (H, Li, B, C, N, O, etc.) play an important role as constituents of many important organic as well inorganic materials in historical and artistic objects. To a large extent these materials occur in the near-surface area of a material with altered or degraded composition

  18. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    International Nuclear Information System (INIS)

    2001-01-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  19. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  20. A Step Forward in Molecular Diagnostics of Lyssaviruses – Results of a Ring Trial among European Laboratories

    NARCIS (Netherlands)

    Fischer, M.; Wernike, K.; Freuling, C.M.; Müller, T.; Aylan, O.; Brochier, B.; Cliquet, F.; Vázquez-Morón, S.; Hostnik, P.; Huovilainen, A.; Isaksson, M.; Kooi, E.A.

    2013-01-01

    Rabies is a lethal and notifiable zoonotic disease for which diagnostics have to meet the highest standards. In recent years, an evolution was especially seen in molecular diagnostics with a wide variety of different detection methods published. Therefore, a first international ring trial

  1. Use, appropriateness, and diagnostic yield of screening colonoscopy: an international observational study (EPAGE)

    DEFF Research Database (Denmark)

    Burnand, B; JK, Harris; Wietlisbach, V

    2006-01-01

    was asked of all centers, it is possible that not all consecutive patients were included. Participating centers were a convenience sample and thus may not be representative. CONCLUSIONS: About 1 of 10 colonoscopies were performed for screening, preferentially in middle-aged individuals. A higher diagnostic...

  2. Molecular Diagnostic Experience of Whole-Exome Sequencing in Adult Patients

    Science.gov (United States)

    Posey, Jennifer E.; Rosenfeld, Jill A.; James, Regis A.; Bainbridge, Matthew; Niu, Zhiyv; Wang, Xia; Dhar, Shweta; Wiszniewski, Wojciech; Akdemir, Zeynep H.C.; Gambin, Tomasz; Xia, Fan; Person, Richard E.; Walkiewicz, Magdalena; Shaw, Chad A.; Sutton, V. Reid; Beaudet, Arthur L.; Muzny, Donna; Eng, Christine M.; Yang, Yaping; Gibbs, Richard A.; Lupski, James R.; Boerwinkle, Eric; Plon, Sharon E.

    2015-01-01

    Purpose Whole exome sequencing (WES) is increasingly used as a diagnostic tool in medicine, but prior reports focus on predominantly pediatric cohorts with neurologic or developmental disorders. We describe the diagnostic yield and characteristics of whole exome sequencing in adults. Methods We performed a retrospective analysis of consecutive WES reports for adults from a diagnostic laboratory. Phenotype composition was determined using Human Phenotype Ontology terms. Results Molecular diagnoses were reported for 17.5% (85/486) of adults, lower than a primarily pediatric population (25.2%; p=0.0003); the diagnostic rate was higher (23.9%) in those 18–30 years of age compared to patients over 30 years (10.4%; p=0.0001). Dual Mendelian diagnoses contributed to 7% of diagnoses, revealing blended phenotypes. Diagnoses were more frequent among individuals with abnormalities of the nervous system, skeletal system, head/neck, and growth. Diagnostic rate was independent of family history information, and de novo mutations contributed to 61.4% of autosomal dominant diagnoses. Conclusion Early WES experience in adults demonstrates molecular diagnoses in a substantial proportion of patients, informing clinical management, recurrence risk and recommendations for relatives. A positive family history was not predictive, consistent with molecular diagnoses often revealed by de novo events, informing the Mendelian basis of genetic disease in adults. PMID:26633545

  3. The future of medical diagnostics: review paper

    LENUS (Irish Health Repository)

    Jerjes, Waseem K

    2011-08-23

    Abstract While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions.

  4. [Molecular diagnostics of ALK-positive lung cancer].

    Science.gov (United States)

    Tímár, József; Lotz, Gábor; Rásó, Erzsébet; Moldvay, Judit

    2017-09-20

    ALK translocation is the 3rd most frequent genetic aberration in lung adenocarcinoma, and several inhibitors are now clinically available in first and second line settings. Accordingly, molecular diagnostics of ALK-positive lung cancer is very important and can be done with the rational combination of several methods. All international recommendations suggest that, except for cytological samples, screening technology for ALK-positive tumors is immunohistochemistry using a validated test. It is highly recommended that in case of ALK protein positive samples gene translocation must be confirmed by fluorescent in situ hybridization (FISH). In case of cytological samples FISH technique must be used as ALK diagnostics. In equivocal cases the genetic alteration of ALK can be confirmed by alternative molecular techniques such as next generation sequencing or RNAbased PCR methods. Upon administration of ALK inhibitors, acquired resistance is frequent which is mostly due to ALK amplification and/or mutation. It is evident that the diagnostics of these secondary ALK gene alterations must be done from recurrent tumors or circulating nucleic acids.

  5. The International Registry on Hand and Composite Tissue Transplantation.

    Science.gov (United States)

    Petruzzo, Palmina; Lanzetta, Marco; Dubernard, Jean-Michel; Landin, Luis; Cavadas, Pedro; Margreiter, Raimund; Schneeberger, Stephan; Breidenbach, Warren; Kaufman, Christina; Jablecki, Jerzy; Schuind, Frédéric; Dumontier, Christian

    2010-12-27

    The International Registry on Hand and Composite Tissue Transplantation was founded in May 2002, and the analysis of all cases with follow-up information up to July 2010 is presented here. From September 1998 to July 2010, 49 hands (17 unilateral and 16 bilateral hand transplantations, including 1 case of bilateral arm transplantation) have been reported, for a total of 33 patients. They were 31 men and 2 women (median age 32 years). Time since hand loss ranged from 2 months to 34 years, and in 46% of cases, the level of amputation was at wrist. Immunosuppressive therapy included tacrolimus, mycophenolate mofetil, sirolimus, and steroids; polyclonal or monoclonal antibodies were used for induction. Topical immunosuppression was also used in several cases. Follow-up ranges from 1 month to 11 years. One patient died on day 65. Three patients transplanted in the Western countries have lost their graft, whereas until September 2009, seven hand grafts were removed for noncompliance to the immunosuppressive therapy in China. Eighty-five percent of recipients experienced at least one episode of acute rejection within the first year, and they were reversible when promptly treated. Side effects included opportunistic infections, metabolic complications, and malignancies. All patients developed protective sensibility, 90% of them developed tactile sensibility, and 82.3% also developed a discriminative sensibility. Motor recovery enabled patients to perform most daily activities. Hand transplantation is a complex procedure, and its success is based on patient's compliance and his or her careful evaluation before and after transplantation.

  6. Development of an Internal Real-Time Wireless Diagnostic Tool for a Proton Exchange Membrane Fuel Cell

    Directory of Open Access Journals (Sweden)

    Chi-Yuan Lee

    2018-01-01

    Full Text Available To prolong the operating time of unmanned aerial vehicles which use proton exchange membrane fuel cells (PEMFC, the performance of PEMFC is the key. However, a long-term operation can make the Pt particles of the catalyst layer and the pollutants in the feedstock gas bond together (e.g., CO, so that the catalyst loses reaction activity. The performance decay and aging of PEMFC will be influenced by operating conditions, temperature, flow and CO concentration. Therefore, this study proposes the development of an internal real-time wireless diagnostic tool for PEMFC, and uses micro-electro-mechanical systems (MEMS technology to develop a wireless and thin (<50 μm flexible integrated (temperature, flow and CO microsensor. The technical advantages are (1 compactness and three wireless measurement functions; (2 elastic measurement position and accurate embedding; (3 high accuracy and sensitivity and quick response; (4 real-time wireless monitoring of dynamic performance of PEMFC; (5 customized design and development. The flexible integrated microsensor is embedded in the PEMFC, three important physical quantities in the PEMFC, which are the temperature, flow and CO, can be measured simultaneously and instantly, so as to obtain the authentic and complete reaction in the PEMFC to enhance the performance of PEMFC and to prolong the service life.

  7. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes.

    Science.gov (United States)

    Kim, Ki-Bong; Hwang, Ho Young; Hahn, Seokyung; Kim, Jun Sung; Oh, Se Jin

    2014-09-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial was designed to evaluate the noninferiority of the saphenous vein (SV) compared with the right internal thoracic artery ([R]ITA) used as a Y-composite graft. A total of 224 patients who had undergone off-pump revascularization for multivessel coronary artery disease using the SV or RITA as a Y-composite graft based on the in situ left ITA were assigned randomly to the SV Y-composite graft (SV group, n = 112) or free RITA Y-composite graft (RITA group, n = 112). The primary endpoint was the 1-year angiographic patency rate of the second limb conduits (SV or RITA). Postoperative 1-year coronary angiograms were performed in 215 patients (SV group, 108; RITA group, 107). The overall graft patency rate was 97.4% (745 of 765) at 1 year (97.9% in the SV group vs 96.9% in the RITA group, P = .362). The primary endpoint of the study, the 1-year patency rate of the SV composite grafts, was 97.1% (238 of 245) and was noninferior to that of the RITA composite grafts (97.1% [198 of 204]) with a 95% lower confidence limit of -2.6% (P RITA composite grafts in terms of the 1-year angiographic patency rates. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Vibration diagnostics instrumentation for ILC

    Energy Technology Data Exchange (ETDEWEB)

    Bertolini, A.

    2007-06-15

    The future e{sup -}e{sup +} 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the accelerator cavities and optical components are demanded to transport and focus the high energy electron and positron beams with reasonable position jitter and low emittance. A brief review of techniques and devices evaluated and developed so far for the vibration diagnostics of the machine is presented in this paper. (orig.)

  9. Vibration diagnostics instrumentation for ILC

    International Nuclear Information System (INIS)

    Bertolini, A.

    2007-06-01

    The future e - e + 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the accelerator cavities and optical components are demanded to transport and focus the high energy electron and positron beams with reasonable position jitter and low emittance. A brief review of techniques and devices evaluated and developed so far for the vibration diagnostics of the machine is presented in this paper. (orig.)

  10. Simplified diagnostic coding sheet for computerized data storage and analysis in ophthalmology.

    Science.gov (United States)

    Tauber, J; Lahav, M

    1987-11-01

    A review of currently-available diagnostic coding systems revealed that most are either too abbreviated or too detailed. We have compiled a simplified diagnostic coding sheet based on the International Coding and Diagnosis (ICD-9), which is both complete and easy to use in a general practice. The information is transferred to a computer, which uses the relevant (ICD-9) diagnoses as database and can be retrieved later for display of patients' problems or analysis of clinical data.

  11. Diagnostics of the Factors Influencing the Export Activity of an Enterprise

    Directory of Open Access Journals (Sweden)

    Skrynkovskyy Ruslan M.

    2017-09-01

    Full Text Available The modern practice of doing business proves that a successful entrance of any enterprise to external (international markets depends on the level of its readiness for carrying out foreign economic activity. Under such circumstances, the process of targeted analysis and assessment of factors influencing the export activity of the enterprise is relevant, expedient and important. The aim of the article is the formation and development of theoretical and methodological bases for diagnosing factors influencing the export activity of an enterprise on the basis of theory and practice in the field of management and administration. It is found that the diagnostics should be understood as the process of identification, analysis and evaluation of influence (functional, dysfunctional of the factors (circumstances, conditions, etc. on the export activity of an enterprise in order to identify and solve problems (current, possible ones in the sphere of supply and implementation of specific actions (steps related to its entrance to external (international markets. It is determined that the key business indicators of the system for diagnosing the factors influencing the export activity of an enterprise are indicators reflecting the influence of the main factors on its export activity: level of fulfillment of obligations in terms of cost; level of conclusion of “expensive contracts”; share of renewed business contracts in the total number of contracts; level of satisfaction of claims; level of delivery variability. The prospect for further research in this scientific direction is developing a system of partial diagnostic goals of the integrated system of goals for conducting economic diagnostics of enterprises taking into account the diagnostics of factors influencing the export activity of an enterprise as a partial diagnostic goal.

  12. Diagnostics of defeats of venous collectors of brain

    International Nuclear Information System (INIS)

    Timofeeva, T.V.; Polunina, I.S.; Shcherbakova, E.Ya.; Kuldakova, S.V.

    1997-01-01

    Comparative data of transcranial ultrasonic dopplerography (170 patients) and radionuclidous antroscintigraphy (124), received during diagnostics of defects of venous collectors of brain are analyzed. Five variants of defeats of venous collectors (cross, sigmoid, internal of jugular of jugular vein), but also unpaired sine (direct, confluent) are described. Received results permit to reveal interrelation of infringements of venous outflow and increase of intracranial pressure

  13. Validation of proposed diagnostic criteria (the "Budapest Criteria") for Complex Regional Pain Syndrome.

    Science.gov (United States)

    Harden, R Norman; Bruehl, Stephen; Perez, Roberto S G M; Birklein, Frank; Marinus, Johan; Maihofner, Christian; Lubenow, Timothy; Buvanendran, Asokumar; Mackey, Sean; Graciosa, Joseph; Mogilevski, Mila; Ramsden, Christopher; Chont, Melissa; Vatine, Jean-Jacques

    2010-08-01

    Current IASP diagnostic criteria for CRPS have low specificity, potentially leading to overdiagnosis. This validation study compared current IASP diagnostic criteria for CRPS to proposed new diagnostic criteria (the "Budapest Criteria") regarding diagnostic accuracy. Structured evaluations of CRPS-related signs and symptoms were conducted in 113 CRPS-I and 47 non-CRPS neuropathic pain patients. Discriminating between diagnostic groups based on presence of signs or symptoms meeting IASP criteria showed high diagnostic sensitivity (1.00), but poor specificity (0.41), replicating prior work. In comparison, the Budapest clinical criteria retained the exceptional sensitivity of the IASP criteria (0.99), but greatly improved upon the specificity (0.68). As designed, the Budapest research criteria resulted in the highest specificity (0.79), again replicating prior work. Analyses indicated that inclusion of four distinct CRPS components in the Budapest Criteria contributed to enhanced specificity. Overall, results corroborate the validity of the Budapest Criteria and suggest they improve upon existing IASP diagnostic criteria for CRPS. Copyright (c) 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  14. NETWORK SERVICES FOR DIAGNOSTIC OPTODIGITAL COMPLEX FOR TELEMEDICINE

    Directory of Open Access Journals (Sweden)

    D. S. Kopylov

    2014-03-01

    Full Text Available The paper deals with a result of the network services development for the optodigital complex for telemedicine diagnostics. This complex is designed for laboratory and clinical tests in health care facilities. Composition of network services includes the following: a client application for database of diagnostic test, a web-service, a web interface, a video server and microimage processing server. Structure of these services makes it possible to combine set of software for transferring depersonalized medical data via the Internet and operating with optodigital devices included in the complex. Complex is consisted of three systems: micro-vision, endoscopic and network. The micro-vision system includes an automated digital microscope with two highly sensitive cameras which can be controlled remotely via the Internet. The endoscopic system gives the possibility to implement video broadcasting to remote users both during diagnostic tests and also off-line after tests. The network system is the core of the complex where network services and application software are functioning, intended for archiving, storage and providing access to the database of diagnostic tests. The following subjects are developed and tested for functional stability: states transfer protocol, commands transfer protocol and video-stream transfer protocol from automated digital microscope and video endoscope. These protocols can work in web browsers on modern mobile devices without additional software.

  15. Diagnostic imaging in medicine. 2. ed.

    International Nuclear Information System (INIS)

    Reba, R.C.; Goodenough, D.J.

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume. (orig.)

  16. International consensus for neuroblastoma molecular diagnostics: report from the International Neuroblastoma Risk Group (INRG) Biology Committee

    Science.gov (United States)

    Ambros, P F; Ambros, I M; Brodeur, G M; Haber, M; Khan, J; Nakagawara, A; Schleiermacher, G; Speleman, F; Spitz, R; London, W B; Cohn, S L; Pearson, A D J; Maris, J M

    2009-01-01

    Neuroblastoma serves as a paradigm for utilising tumour genomic data for determining patient prognosis and treatment allocation. However, before the establishment of the International Neuroblastoma Risk Group (INRG) Task Force in 2004, international consensus on markers, methodology, and data interpretation did not exist, compromising the reliability of decisive genetic markers and inhibiting translational research efforts. The objectives of the INRG Biology Committee were to identify highly prognostic genetic aberrations to be included in the new INRG risk classification schema and to develop precise definitions, decisive biomarkers, and technique standardisation. The review of the INRG database (n=8800 patients) by the INRG Task Force finally enabled the identification of the most significant neuroblastoma biomarkers. In addition, the Biology Committee compared the standard operating procedures of different cooperative groups to arrive at international consensus for methodology, nomenclature, and future directions. Consensus was reached to include MYCN status, 11q23 allelic status, and ploidy in the INRG classification system on the basis of an evidence-based review of the INRG database. Standardised operating procedures for analysing these genetic factors were adopted, and criteria for proper nomenclature were developed. Neuroblastoma treatment planning is highly dependant on tumour cell genomic features, and it is likely that a comprehensive panel of DNA-based biomarkers will be used in future risk assignment algorithms applying genome-wide techniques. Consensus on methodology and interpretation is essential for uniform INRG classification and will greatly facilitate international and cooperative clinical and translational research studies. PMID:19401703

  17. Diagnostic work-up and loss of tuberculosis suspects in Jogjakarta, Indonesia.

    Science.gov (United States)

    Ahmad, Riris Andono; Matthys, Francine; Dwihardiani, Bintari; Rintiswati, Ning; de Vlas, Sake J; Mahendradhata, Yodi; van der Stuyft, Patrick

    2012-02-15

    Early and accurate diagnosis of pulmonary tuberculosis (TB) is critical for successful TB control. To assist in the diagnosis of smear-negative pulmonary TB, the World Health Organisation (WHO) recommends the use of a diagnostic algorithm. Our study evaluated the implementation of the national tuberculosis programme's diagnostic algorithm in routine health care settings in Jogjakarta, Indonesia. The diagnostic algorithm is based on the WHO TB diagnostic algorithm, which had already been implemented in the health facilities. We prospectively documented the diagnostic work-up of all new tuberculosis suspects until a diagnosis was reached. We used clinical audit forms to record each step chronologically. Data on the patient's gender, age, symptoms, examinations (types, dates, and results), and final diagnosis were collected. Information was recorded for 754 TB suspects; 43.5% of whom were lost during the diagnostic work-up in health centres, 0% in lung clinics. Among the TB suspects who completed diagnostic work-ups, 51.1% and 100.0% were diagnosed without following the national TB diagnostic algorithm in health centres and lung clinics, respectively. However, the work-up in the health centres and lung clinics generally conformed to international standards for tuberculosis care (ISTC). Diagnostic delays were significantly longer in health centres compared to lung clinics. The high rate of patients lost in health centres needs to be addressed through the implementation of TB suspect tracing and better programme supervision. The national TB algorithm needs to be revised and differentiated according to the level of care.

  18. [Allergy and autoimmunity: Molecular diagnostics, therapy, and presumable pathogenesis].

    Science.gov (United States)

    Arefieva, A S; Smoldovskaya, O V; Tikhonov, A A; Rubina, A Yu

    2017-01-01

    Allergic and autoimmune diseases represent immunopathological reactions of an organism to antigens. Despite that the allergy is a result of exaggerated immune response to foreign antigens (allergens) and autoimmune diseases are characterized by the pathological response to internal antigens (autoantigens), the underlying mechanisms of these diseases are probably common. Thus, both types of diseases represent variations in the hypersensitivity reaction. A large percentage of both the adult and pediatric population is in need of early diagnostics of these pathologies of the immune system. Considering the diversity of antibodies produced in allergic and autoimmune disease and the difficulties accompanying clinical diagnosing, molecular diagnostics of these pathological processes should be carried out in several stages, including screening and confirmatory studies. In this review, we summarize the available data on the molecular diagnostics and therapy of allergic and autoimmune diseases and discuss the basic similarities and differences in the mechanisms of their development.

  19. INCLEN diagnostic tool for attention deficit hyperactivity disorder (INDT-ADHD): development and validation.

    Science.gov (United States)

    Mukherjee, Sharmila; Aneja, Satinder; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K

    2014-06-01

    To develop and validate INCLEN Diagnostic Tool for Attention Deficit Hyperactivity Disorder (INDT-ADHD). Diagnostic test evaluation by cross sectional design. Tertiary care pediatric centers. 156 children aged 65-117 months. After randomization, INDT-ADHD and Connors 3 Parent Rating Scale (C3PS) were administered, followed by an expert evaluation by DSM-IV-TR diagnostic criteria. Psychometric evaluation of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. INDT-ADHD had 18 items that quantified symptoms and impairment. Attention deficit hyperactivity disorder was identified in 57, 87 and 116 children by expert evaluation, INDT-ADHD and C3PS, respectively. Psychometric parameters of INDT-ADHD for differentiating attention deficit hyperactivity disorder and normal children were: sensitivity 87.7%, specificity 97.2%, positive predictive value 98.0% and negative predictive value 83.3%, whereas for differentiating from other neuro-developmental disorders were 87.7%, 42.9%, 58.1% and 79.4%, respectively. Internal consistency was 0.91. INDT-ADHD has a 4-factor structure explaining 60.4% of the variance. Convergent validity with Conner's Parents Rating Scale was moderate (r =0.73, P= 0.001). INDT-ADHD is suitable for diagnosing attention deficit hyperactivity disorder in Indian children between the ages of 6 to 9 years.

  20. Interlaboratory diagnostic accuracy of a Salmonella specific PCR-based method

    DEFF Research Database (Denmark)

    Malorny, B.; Hoorfar, Jeffrey; Hugas, M.

    2003-01-01

    A collaborative study involving four European laboratories was conducted to investigate the diagnostic accuracy of a Salmonella specific PCR-based method, which was evaluated within the European FOOD-PCR project (http://www.pcr.dk). Each laboratory analysed by the PCR a set of independent obtained...... presumably naturally contaminated samples and compared the results with the microbiological culture method. The PCR-based method comprised a preenrichment step in buffered peptone water followed by a thermal cell lysis using a closed tube resin-based method. Artificially contaminated minced beef and whole......-based diagnostic methods and is currently proposed as international standard document....

  1. Diagnostic criteria for hereditary hemorrhagic telangiectasia (Rendu-Osler-Weber syndrome)

    DEFF Research Database (Denmark)

    Shovlin, C L; Guttmacher, A E; Buscarini, E

    2000-01-01

    Hereditary Hemorrhagic Telangiectasia (HHT) is easily recognized in individuals displaying the classical triad of epistaxis, telangiectasia, and a suitable family history, but the disease is more difficult to diagnosis in many patients. Serious consequences may result if visceral arteriovenous ma...... in this disorder. These criteria may be refined as molecular diagnostic tests become available in the next few years....... of the HHT Foundation International, Inc., we present consensus clinical diagnostic criteria. The four criteria (epistaxes, telangiectasia, visceral lesions and an appropriate family history) are carefully delineated. The HHT diagnosis is definite if three criteria are present. A diagnosis of HHT cannot...

  2. Automatic brain caudate nuclei segmentation and classification in diagnostic of Attention-Deficit/Hyperactivity Disorder.

    Science.gov (United States)

    Igual, Laura; Soliva, Joan Carles; Escalera, Sergio; Gimeno, Roger; Vilarroya, Oscar; Radeva, Petia

    2012-12-01

    We present a fully automatic diagnostic imaging test for Attention-Deficit/Hyperactivity Disorder diagnosis assistance based on previously found evidences of caudate nucleus volumetric abnormalities. The proposed method consists of different steps: a new automatic method for external and internal segmentation of caudate based on Machine Learning methodologies; the definition of a set of new volume relation features, 3D Dissociated Dipoles, used for caudate representation and classification. We separately validate the contributions using real data from a pediatric population and show precise internal caudate segmentation and discrimination power of the diagnostic test, showing significant performance improvements in comparison to other state-of-the-art methods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Laser diagnostics of materials and chemistry

    International Nuclear Information System (INIS)

    Hartford, A. Jr.

    1984-01-01

    Several examples are given of the ability of laser-based diagnostic techniques to make noninvasive measurements in hostile environments. Using coherent anti-Stokes Raman scattering both majority and minority species concentrations, as well as temperature, have been measured in the hot, high-pressure, particle-laden stream of a coal gasifier. In addition, numerous toxic and corrosive elements in the gasifier stream have been identified, but not yet quantified. In addition to providing the capability for making analytical determinations, laser techniques have been extensively employed to measure the rates of elementary chemical reactions. Recently, the temperature regime over which such meaurements are possible has been expanded. Although much of the laser diagnostic activity to date has involved investigations of the gas phase, significant information concerning heterogeneous phenomena can still be inferred. For instance, gas-solid reactions can manifest themselves as changes in vapor phase composition. Furthermore, in the future we expect expanded studies involving reactions of refractory metals (both atoms and clusters) and additional investigations of processes occurring at interfaces and on surfaces

  4. MAST magnetic diagnostics

    Science.gov (United States)

    Edlington, T.; Martin, R.; Pinfold, T.

    2001-01-01

    The mega-ampere spherical tokamak (MAST) experiment is a new, large, low aspect ratio device (R=0.7-0.8 m, a=0.5-0.65 m, maximum BT˜0.63 T at R=0.7 m) operating its first experimental physics campaign. Designed to study a wide variety of plasma shapes with up to 2 MA of plasma current with an aspect ratio down to 1.3, the poloidal field (PF) coils used for plasma formation, equilibrium and shaping are inside the main vacuum vessel. For plasma control and to investigate a wide range of plasma phenomena, an extensive set of magnetic diagnostics have been installed inside the vacuum vessel. More than 600 vacuum compatible, bakeable diagnostic coils are configured in a number of discrete arrays close to the plasma edge with about half the coils installed behind the graphite armour tiles covering the center column. The coil arrays measure the toroidal and poloidal variation in the equilibrium field and its high frequency fluctuating components. Internal coils also measure currents in the PF coils, plasma current, stored energy and induced currents in the mechanical support structures of the coils and graphite armour tiles. The latter measurements are particularly important when halo currents are induced following a plasma termination, for example, when the plasma becomes vertically unstable. The article describes the MAST magnetic diagnostic coil set and their calibration. The way in which coil signals are used to control the plasma equilibrium is described and data from the first MAST experimental campaign presented. These coil data are used as input to the code EFIT [L. Lao et al., Nucl. Fusion 25, 1611 (1985)], for measurement of halo currents in the vacuum vessel structure and for measurements of the structure of magnetic field fluctuations near the plasma edge.

  5. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  6. Molecular diagnostic experience of whole-exome sequencing in adult patients.

    Science.gov (United States)

    Posey, Jennifer E; Rosenfeld, Jill A; James, Regis A; Bainbridge, Matthew; Niu, Zhiyv; Wang, Xia; Dhar, Shweta; Wiszniewski, Wojciech; Akdemir, Zeynep H C; Gambin, Tomasz; Xia, Fan; Person, Richard E; Walkiewicz, Magdalena; Shaw, Chad A; Sutton, V Reid; Beaudet, Arthur L; Muzny, Donna; Eng, Christine M; Yang, Yaping; Gibbs, Richard A; Lupski, James R; Boerwinkle, Eric; Plon, Sharon E

    2016-07-01

    Whole-exome sequencing (WES) is increasingly used as a diagnostic tool in medicine, but prior reports focus on predominantly pediatric cohorts with neurologic or developmental disorders. We describe the diagnostic yield and characteristics of WES in adults. We performed a retrospective analysis of consecutive WES reports for adults from a diagnostic laboratory. Phenotype composition was determined using Human Phenotype Ontology terms. Molecular diagnoses were reported for 17.5% (85/486) of adults, which is lower than that for a primarily pediatric population (25.2%; P = 0.0003); the diagnostic rate was higher (23.9%) for those 18-30 years of age compared to patients older than 30 years (10.4%; P = 0.0001). Dual Mendelian diagnoses contributed to 7% of diagnoses, revealing blended phenotypes. Diagnoses were more frequent among individuals with abnormalities of the nervous system, skeletal system, head/neck, and growth. Diagnostic rate was independent of family history information, and de novo mutations contributed to 61.4% of autosomal dominant diagnoses. Early WES experience in adults demonstrates molecular diagnoses in a substantial proportion of patients, informing clinical management, recurrence risk, and recommendations for relatives. A positive family history was not predictive, consistent with molecular diagnoses often revealed by de novo events, informing the Mendelian basis of genetic disease in adults.Genet Med 18 7, 678-685.

  7. DIAGNOSTIC VALUE OF SEROLOGICAL MARKERS OF RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    Aleksei Leonidovich Maslaynski

    2012-01-01

    Full Text Available Rheumatoid arthritis (RA is a classic autoimmune disease associated with the production of wide range of autoantibodies, and their detection has diagnostic and prognostic implication. The objective of this study was to estimate the diagnostic value of antibodies against modified citrullinated vimentin (AMCV and nuclear antigen RA33 of the IgA rheumatoid factor (RF versus the value of routinely used profile of autoantibodies in diagnostic work-up of RA. Material and methods. 253 patients with RA prehistory of varying duration were included into the study group. The control group was comprised of 92 patients, including patients with seronegative spondyloarthropathies and diffuse connective tissue diseases, as well as sex and age matched healthy controls. Serum levels of IgM and IgA RF, antibodies against cyclic citrullinated peptide (ACCP, ACMV, anti-keratin antibodies (AKA, antibodies against RA33 antigen (ARA33 and antinuclear factor (ANF were measured in all patients and controls. Results and discussion. Diagnostic sensitivity of AMCV equaled 78%, ACCP — 77%, IgM RF — 71%, IgA RF — 43%, AKA — 43%, ARA33 — 31% and ANF — 31%. All anti-citrullinic antibodies (AKA, ACCP, ACMV were significantly more commonly associated with IgM RF. Among RF and ACCP seronegative patients ACMV were found in 24% cases with 20 IU/Ml detection threshold, and in 21% — with 30 IU/Ml, allowing to increase diagnostic specificity of the test up to 91% with the increment of diagnostic threshold. Incidence of ARA33 was not significantly different among the RF and ACCP positive or negative subgroups, thus making ARA33 an independent RA marker. Specificity of this marker was 87,9%, thus making it inferior to RF and ACCP by a composite of diagnostic characteristics. Conclusions. Integrated measurement of ACMV and ARA33 is a rational approach at the second stage of serologic testing work-up in suspected cases of RA onset, when initial RF and ACCP tests were negative.

  8. Clinical Factors and Disease Course Related to Diagnostic Delay in Korean Crohn's Disease Patients: Results from the CONNECT Study.

    Directory of Open Access Journals (Sweden)

    Chang Mo Moon

    Full Text Available Diagnostic delay frequently occurs in Crohn's disease (CD patients because of diagnostic limitations. However, diagnostic delay and its related factors remain poorly defined. Therefore, we aimed to identify the predictors associated with diagnostic delay and to evaluate the impact of diagnostic delay on clinical course in a Korean CD patient cohort. We performed a multicenter retrospective analysis of 1,047 CD patients registered in the Crohn's Disease Clinical Network and Cohort study in Korea. The mean interval of diagnostic delay was 16.0 ± 33.1 months. Multivariate analysis showed that older age at diagnosis (≥40 years (p = 0.014, concomitant upper gastrointestinal (UGI disease (p = 0.012 and penetrating disease behavior at diagnosis (p = 0.001 were positively associated with long diagnostic delay (≥18 months. During the longitudinal follow-up, long diagnostic delay was independently predictive of further development of intestinal stenosis (hazard ratio [HR], 1.43; 95% confidence interval [CI], 1.07-1.93; p = 0.017, internal fistulas (HR, 1.62; 95% CI, 1.12-2.33; p = 0.011, and perianal fistulas (HR, 1.38; 95% CI, 1.06-1.80; p = 0.016. However, as for the risk of abscess formation, bowel perforation, and CD-related abdominal surgery, no significant association with diagnostic delay was observed. Older age at diagnosis, UGI involvement, and penetrating behavior are associated with long diagnostic delay in Korean CD patients. Moreover, diagnostic delay is associated with an increased risk of CD-related complications such as intestinal stenosis, internal fistulas, and perianal fistulas.

  9. High energy flux thermo-mechanical test of 1D-carbon-carbon fibre composite prototypes for the SPIDER diagnostic calorimeter

    International Nuclear Information System (INIS)

    De Muri, M.; Pasqualotto, R.; Dalla Palma, M.; Cervaro, V.; Fasolo, D.; Franchin, L.; Tollin, M.; Serianni, G.; Cavallin, T.; Greuner, H.; Böswirth, B.

    2014-01-01

    Operation of the thermonuclear fusion experiment ITER requires additional heating via injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction in Padova, the production of negative ions will be studied and optimised. STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic used to characterise the SPIDER beam during short pulse operation (several seconds) to verify if the beam meets the ITER requirements about the maximum allowed beam non-uniformity (below ±10%). The major components of STRIKE are 16 1D-CFC (Carbon-Carbon Fibre Composite) tiles, observed at the rear side by a thermal camera. This contribution gives an overview of some tests under high energy particle flux, aimed at verifying the thermo-mechanical behaviour of several CFC prototype tiles. The tests were performed in the GLADIS facility at IPP (Max-Plank-Institut für Plasmaphysik), Garching. Dedicated linear and nonlinear simulations were carried out to interpret the experiments and a comparison of the experimental data with the simulation results is presented. The results of some morphological and structural studies on the material after exposure to the GLADIS beam are also given

  10. Evaluation of entrance skin dose to the skull in diagnostic radiology

    International Nuclear Information System (INIS)

    Mohamed, Anas Ali Elbushari

    2015-12-01

    Diagnostic x-ray radiology is a common diagnostic practice.Despite of its increasing hazard to human beings, imaging procedures should be achieved with less radiation dose and sufficient image quality. The aim of this study was to estimate the entrance skin dose(ESD) for patients undergoing selected diagnostic x-ray examinations in four hospitals.The study included the examinations of the skull; posterior- anterior(PA) and lateral projections. Fifty patients were enrolled in this study. ESDs were estimated from patients specific exposure parameters using established relation between output (μGy/mAs) and tube voltage(kVp). The estimated ESDs ranged from 0.0097-0.1846 mGy for skull (PA), 0.0097-0.1399 mGy for skull (LAT). These values were acceptable as compared with the international reference dose levels. This study provides additional data that can help the regulatory authority to establish reference dose levels for diagnostic radiology in Sudan.(Author)

  11. Method of reduction of diagnostic parameters during observation on the example of a combustion engine

    Directory of Open Access Journals (Sweden)

    Orczyk Malgorzata

    2017-01-01

    Full Text Available The article presents a method of selecting diagnostic parameters which map the process of damaging the object. This method consists in calculating, during the observation, the correlation coefficient between the intensity of damage and the individual diagnostic parameters; and discarding of those parameters whose correlation coefficient values are outside of the narrowest confidence interval of the correlation coefficient. The characteristic feature of this method is that the parameters are reduced during the diagnostic experiment. The essence of the proposed method is illustrated by the vibration diagnosis of an internal combustion engine.

  12. SYSTEM OF CONTROL FOR ACTIVE CAR SUSPENSION CHARACTERISTICS IN THE COMPOSITION OF THE EXPRESS DIAGNOSTICS LINE

    Directory of Open Access Journals (Sweden)

    Y. Borodenko

    2017-12-01

    Full Text Available The issues related to the organization and technical implementation of the control area for the output parameters of the active pendants as part of the technical control line are considered. An option is proposed to complete the baseline of express diagnostics with an additional bench for checking the angles of installation of the rear axle wheels. To reduce the cost of hardware implementation and increase the productivity of the measuring complex, it is proposed to compile software for computer diagnostic tools into a single testing.

  13. DIAGNOSTICS AND THERAPY IN CHILDREN'S ACUTE GASTROENTERITIS

    Directory of Open Access Journals (Sweden)

    M.D. Bakradze

    2007-01-01

    Full Text Available The work aimed at studying a series of diagnostic aspects and determination of the possible treatment of children with acute gastroenetrites according to the protocol based on international recommendations and standards. The study involved 130 children, of whom in 71 patients the presence of rotavirus antigen in coprofilters was checked via latex particle agglutination method. In 85% rotavirus infection was confirmed. It was shown that the majority of cases fall on November to may. Infant and early children are the most susceptible to rotavirus gastroenteritis. The analysis of therapy results showed that antibioticsfree treatment of watery diarrhea patients worked well, and prescription of antibacterial therapy for the concomitant bacterial infection does not influence the time of gastroenteritis reduction. The results of dehydration therapy show that oral rehydration is not always effective for the 2nd stage dehydration, especially with late treatment. However, the time of recovery (diarrhea reduction does not depend on the type of rehydration or symptomatic therapy. A diagnostic algorithm that helps use the minimum diagnostic methods in stationary conditions and at the same time provides the optimum scope of therapeutic intervention was worked out.Key words: rotavirus infection, children, rehydration, antibacterial therapy.

  14. Alternative international currencies

    Directory of Open Access Journals (Sweden)

    Rozhentsova Vladimirovna Elena

    2012-01-01

    Full Text Available The modern international monetary system has a number of flaws and therefore needs cardinal change. Hence, economists from all over the world are suggesting alternative international currencies that would make the international monetary system more efficient. However, it is essential when approaching the creation of a new international currency to analyze and take into account the experience of all the past international currencies. Therefore this paper begins with an exploration of the drawbacks of each of the past and present international currencies. Drawing on this analysis a justification will be made for the necessity of introducing a new international currency, pointing to the requirements it should meet. Further on, this paper proposes an alternative theoretically possible variant of the international currency, with a fixed value relative to a commodity basket. An abstract example is used to demonstrate its composition and circulation mechanism.

  15. Diagnostic work-up and loss of tuberculosis suspects in Jogjakarta, Indonesia

    Directory of Open Access Journals (Sweden)

    Ahmad Riris

    2012-02-01

    Full Text Available Abstract Background Early and accurate diagnosis of pulmonary tuberculosis (TB is critical for successful TB control. To assist in the diagnosis of smear-negative pulmonary TB, the World Health Organisation (WHO recommends the use of a diagnostic algorithm. Our study evaluated the implementation of the national tuberculosis programme's diagnostic algorithm in routine health care settings in Jogjakarta, Indonesia. The diagnostic algorithm is based on the WHO TB diagnostic algorithm, which had already been implemented in the health facilities. Methods We prospectively documented the diagnostic work-up of all new tuberculosis suspects until a diagnosis was reached. We used clinical audit forms to record each step chronologically. Data on the patient's gender, age, symptoms, examinations (types, dates, and results, and final diagnosis were collected. Results Information was recorded for 754 TB suspects; 43.5% of whom were lost during the diagnostic work-up in health centres, 0% in lung clinics. Among the TB suspects who completed diagnostic work-ups, 51.1% and 100.0% were diagnosed without following the national TB diagnostic algorithm in health centres and lung clinics, respectively. However, the work-up in the health centres and lung clinics generally conformed to international standards for tuberculosis care (ISTC. Diagnostic delays were significantly longer in health centres compared to lung clinics. Conclusions The high rate of patients lost in health centres needs to be addressed through the implementation of TB suspect tracing and better programme supervision. The national TB algorithm needs to be revised and differentiated according to the level of care.

  16. Preparation and Mechanical Properties of Aligned Discontinuous Carbon Fiber Composites

    OpenAIRE

    DENG Hua; GAO Junpeng; BAO Jianwen

    2018-01-01

    Aligned discontinuous carbon fiber composites were fabricated from aligned discontinuous carbon fiber prepreg, which was prepared from continuous carbon fiber prepreg via mechanical high-frequency cutting. The internal quality and mechanical properties were characterized and compared with continuous carbon fiber composites. The results show that the internal quality of the aligned discontinuous carbon fiber composites is fine and the mechanical properties have high retention rate after the fi...

  17. Current aspects in the development of the quality control in the conventional X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Velkova, K.

    2004-01-01

    The role of the X-ray diagnostic radiology as one of the main factors forming the general public dose is indisputable. Following the requirement for justification of the application of X-rays for medical purposes, certain criteria for assessment of the parameters of the X-ray diagnostic equipment are formed and maximum permissible values defined. The latter are developed by the international and national radiation protection organizations and introduced both in the international and national legislation. The importance of the quality assurance concept for the radiation protection of the patient and staff in diagnostic radiology turned the quality control into main toll for obtaining high quality images with minimum dose to the patient and staff. X-ray diagnostics is one of the most common methods used in the medical practice. This is the main reason for the increase of the quality control protocols, winch makes their handling difficult. The latest developments in this area bring forward the idea for the development of specialized quality control software, which is capable of: 1) full or semi-automated calculation and assessment of the parameters of the X-ray diagnostic units; 2) tools for data handling and access; 3) tools for data analysis based on predefined procedures

  18. Diagnostic Evasion of Highly-Resistant Microorganisms: A Critical Factor in Nosocomial Outbreaks.

    Science.gov (United States)

    Zhou, Xuewei; Friedrich, Alexander W; Bathoorn, Erik

    2017-01-01

    Highly resistant microorganisms (HRMOs) may evade screening strategies used in routine diagnostics. Bacteria that have evolved to evade diagnostic tests may have a selective advantage in the nosocomial environment. Evasion of resistance detection can result from the following mechanisms: low-level expression of resistance genes not resulting in detectable resistance, slow growing variants, mimicry of wild-type-resistance, and resistance mechanisms that are only detected if induced by antibiotic pressure. We reviewed reports on hospital outbreaks in the Netherlands over the past 5 years. Remarkably, many outbreaks including major nation-wide outbreaks were caused by microorganisms able to evade resistance detection by diagnostic screening tests. We describe various examples of diagnostic evasion by several HRMOs and discuss this in a broad and international perspective. The epidemiology of hospital-associated bacteria may strongly be affected by diagnostic screening strategies. This may result in an increasing reservoir of resistance genes in hospital populations that is unnoticed. The resistance elements may horizontally transfer to hosts with systems for high-level expression, resulting in a clinically significant resistance problem. We advise to communicate the identification of HRMOs that evade diagnostics within national and regional networks. Such signaling networks may prevent inter-hospital outbreaks, and allow collaborative development of adapted diagnostic tests.

  19. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics.

    Science.gov (United States)

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J; Sobrinho Simoes, Manuel

    2017-07-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF , NRAS , HRAS , KRAS , PAX8/PPARG , RET/PTC ) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation.

  20. Diagnostics vehicle’s condition using obd-ii and raspberry pi technology: study literature

    Science.gov (United States)

    Moniaga, J. V.; Manalu, S. R.; Hadipurnawan, D. A.; Sahidi, F.

    2018-03-01

    Transportation accident rate are still being a major challenge in many countries. There are many factors that could be cause transportation accident, especially in vehicle’s internal system problem. To overcome this problem, OBD-II technology has been created to diagnostics vehicle’s condition. OBD-II scanner plugged to OBD-II port or usually called Data Link Connector (DLC), and after that it sends the diagnostics to Raspberry Pi. Compared from another microcontrollers, Arduino, Raspberry Pi are chosen because it sustains the application to receive real-time diagnostics, process the diagnostics and send command to automobiles at the same time, rather than Arduino that must wait for another process finished to run another process. Outcome from this application is to enable automobile’s user to diagnostics their own vehicles. If there is found something unusual or a problem, the application can told the problem to user, so they could know what to fix before they use their vehicle safely.

  1. Composite materials research and education program: The NASA-Virginia Tech composites program

    Science.gov (United States)

    Herakovich, C. T.

    1980-01-01

    Major areas of study include: (1) edge effects in finite width laminated composites subjected to mechanical, thermal and hygroscopic loading with temperature dependent material properties and the influence of edge effects on the initiation of failure; (2) shear and compression testing of composite materials at room and elevated temperatures; (3) optical techniques for precise measurement of coefficients of thermal expansion of composites; (4) models for the nonlinear behavior of composites including material nonlinearity and damage accumulation and verification of the models under biaxial loading; (5) compressive failure of graphite/epoxy plates with circular holes and the buckling of composite cylinders under combined compression and torsion; (6) nonlinear mechanical properties of borsic/aluminum, graphite/polyimide and boron/aluminum; (7) the strength characteristics of spliced sandwich panels; and (8) curved graphite/epoxy panels subjected to internal pressure.

  2. Technical Analysis of the Slosson-Diagnostic Math Screener (S-DMS)

    Science.gov (United States)

    Erford, Bradley T.; Klein, Lauren

    2007-01-01

    The Slosson-Diagnostic Math Screener (S-DMS) was designed to help identify students in Grades 1 to 8 at risk for mathematics failure. Internal consistency, test-retest reliability, item analysis, decision efficiency, convergent validity, and factorial validity of all five levels of the S-DMS were studied using 20 independent samples of students…

  3. Vibration characteristics of functionally graded carbon nanotube reinforced composite rectangular plates on Pasternak foundation with arbitrary boundary conditions and internal line supports

    Science.gov (United States)

    Zhong, Rui; Wang, Qingshan; Tang, Jinyuan; Shuai, Cijun; Liang, Qian

    2018-02-01

    This paper presents the first known vibration characteristics of moderately thick functionally graded carbon nanotube reinforced composite rectangular plates on Pasternak foundation with arbitrary boundary conditions and internal line supports on the basis of the firstorder shear deformation theory. Different distributions of single walled carbon nanotubes (SWCNTs) along the thickness are considered. Uniform and other three kinds of functionally graded distributions of carbon nanotubes along the thickness direction of plates are studied. The solutions carried out using an enhanced Ritz method mainly include the following three points: Firstly, create the Lagrange energy function by the energy principle; Secondly, as the main innovation point, the modified Fourier series are chosen as the basic functions of the admissible functions of the plates to eliminate all the relevant discontinuities of the displacements and their derivatives at the edges; Lastly, solve the natural frequencies as well as the associated mode shapes by means of the Ritz-variational energy method. In this study, the influences of the volume fraction of CNTs, distribution type of CNTs, boundary restrain parameters, location of the internal line supports, foundation coefficients on the natural frequencies and mode shapes of the FG-CNT reinforced composite rectangular plates are presented.

  4. Investigation of Circular Woven Composite Preforms for Composite Pipes

    Directory of Open Access Journals (Sweden)

    Amid Hooman

    2016-06-01

    Full Text Available The main traditional technique for commercial manufacturing of composite pipes is filament winding in which the winding angle and the discontinuity of the structure (caused by starting and ending points of the winding process are two important matters of concern. In the present study, circular woven fabric with its orthogonal net-shaped continuous structure was produced from polyester yarns. Fabric was wet with epoxy and hand lay-up was used to manufacture the composite pipes. Composite pipes were subjected to internal hydrostatic pressure and their burst strength was recorded. In addition, tensile strength of flat laminas was assessed in the warp and weft directions. We estimated and analysed the failure strength of composite pipes using Tresca’s failure criterion and Finite Element (FE modeling. The experimental burst strength was almost 23% more than the FE model and 77% more than the theoretical estimate.

  5. Diagnostic validity of criteria for sacroiliac joint pain: a systematic review

    NARCIS (Netherlands)

    Szadek, K.M.; van der Wurff, P.; van Tulder, M.W.; Zuurmond, W.W.A.; Perez, R.S.G.M.

    2009-01-01

    A systematic literature review was conducted to determine the diagnostic validity of the criteria for sacroiliac (SI) joint pain as proposed by the International Association for the Study of Pain (IASP). Databases were searched up to September 2007. Quality of the studies was assessed using a

  6. Diagnostic Validity of Criteria for Sacroiliac Joint Pain : A Systematic Review

    NARCIS (Netherlands)

    Szadek, Karolina M.; van der Wurff, Peter; van Tulder, Maurits W.; Zuurmond, Wouter W.; Perez, Roberto S. G. M.

    A systematic literature review was conducted to determine the diagnostic validity of the criteria for sacroiliac (SI) joint pain as proposed by the International Association for the Study of Pain (IASP). Databases were searched up to September 2007. Quality of the studies was assessed using a

  7. Role of a diagnostic laboratory in the management of diabetes mellitus

    African Journals Online (AJOL)

    Nigerian Journal of Clinical Practice ... To elucidate the role of a modern diagnostic laboratory in the management of diabetesmellitus Available literature on local and international studies on the role of the laboratory in the management of diabetesmellitus Preclinical diagnosis of diabetes mellitus, good monitoring of short, ...

  8. Efficient radiological assessment of the internal snapping hip syndrome

    International Nuclear Information System (INIS)

    Wunderbaldinger, P.; Bremer, C.; Matuszewski, L.; Marten, K.; Turetschek, K.; Rand, T.

    2001-01-01

    The aim of this study was to evaluate the diagnostic value/significance of various imaging techniques for demonstrating the underlying causative pathology of clinically suspected internal snapping hip syndrome. We intended to define the most efficient diagnostic imaging algorithm that leads to a specific definite therapy for this rare hip disorder. The imaging studies of 54 patients (43 women, 11 men, average age 58 years) with the clinical suspicion of internal snapping hip syndrome were compared for their diagnostic value/significance for finding the underlying pathology. Radiological workup included plain radiographs of the pelvis and hip joints (n=54), ultrasound (US) of the hip joints (n=29), computed tomography (CT) of the pelvis and proximal femur (n=17), and magnetic resonance imaging (MRI) of the pelvis/hip joint (n=21). In order to establish an efficient diagnostic algorithm we compared the diagnostic value of each imaging technique alone and in combination with the other methods. The underlying causative pathology could be established in 37% of patients (n=20) by the use of conventional radiographs alone and in 46% of the patients (n=25) by US alone, and in combination in 83% of the patients (n=45). By adding CT to the radiological workup, we established final diagnosis in 88% (in combination with X-ray; n=15/17) and 94% (together with X-ray and US; n=16/17) of the patients. Whenever MR imaging was used a causative pathology was found in all patients (100%; n=21). The most efficient radiological algorithm in the assessment of patients with internal snapping hip syndrome is the combination of plain radiography and US. MR imaging can be retained for unresolved and difficult cases. (orig.)

  9. Effect of patient age awareness on diagnostic agreement of chronic or aggressive periodontitis between clinicians; a pilot study

    OpenAIRE

    Oshman, Sarah; El Chaar, Edgard; Lee, Yoonjung Nicole; Engebretson, Steven

    2016-01-01

    Background The aim of this pilot study was to test whether diagnostic agreement of aggressive and chronic periodontitis amongst Board Certified Periodontists, is influenced by knowledge of a patient?s age. In 1999 at the International World Workshop age was removed as a diagnostic criteria for aggressive periodontitis. The impact of this change on the diagnostic reliability amongst clinicians has not yet been assessed. Methods Nine periodontal case reports were twice presented to sixteen boar...

  10. Biomedical microanalysis--putting it to work now in diagnostic pathology

    International Nuclear Information System (INIS)

    Abraham, J.L.

    1980-01-01

    Based on a review of seven years' experience with microanalysis in human pathology, the emphasis of this keynote paper is that currently available microanalytic instrumentation and methodology are of great use diagnostically. The appropriate diagnostic questions which must be posed for microanalysis center around those seeking the cause of the disease (etiologic diagnosis). The preventive and forensic aspects of etiologic diagnosis are stressed. Pathologists analyse not only tissues but also material samples. The backscattered electron (BSE) image with compositional contrast has been essential in making efficient diagnostic use of microanalysis in the scanning electron microscope (SEM). From the 454 specimens seen in the four years 1976-1979, examples are presented to illustrate several aspects of microanalysis: e.g., documentation of the identity and source of toxic dust in lungs; identification of particulate materials in liver, kidney, salivary glands, lymph nodes, etc.; problems of contamination of specimens; use of high vs low magnification analysis; relative volume of tissue sampled using thick (5 micrometer) vs thin (100nm) sections; time required for analysis; and use of fresh frozen, cryo-sectioned tissue for analysis of soluble materials. For practical diagnostic microanalysis, SEM with BSE and x-ray microanalysis of 5 micrometer thick tissue sections at present seems to be the most efficient procedure

  11. Nickel/Diamond Composite Coating Prepared by High Speed Electrodeposition

    Directory of Open Access Journals (Sweden)

    ZHANG Yan

    2016-10-01

    Full Text Available Nickel/diamond composite coatings were prepared on the basis of a new high speed electroplating bath. The influence of additives, plating parameters and diamond concentration on internal stress was investigated in order to find the solution to decrease the stress introduced by high current density; the micro morphology of the coatings were observed by SEM. The bath and depositing parameters were optimized that thick nickel/diamond composite coatings with low internal stress can be high speed electroplated with a high cathode current density of 30A/dm2. The results show that when plated with bath composition and parameters as follows: sodium dodecyl sulfate 0.5g/L, ammonium acetate 3g/L, sodium citrate 1.5g/L, diamond particles 30g/L; pH value 3-4, temperature 50℃, the composite coatings prepared in high speed have the lowest internal stress.

  12. 5. All-Russian (international) scientific conference. Physicochemical processes during selection of atoms and molecules. Program of the conference and summary of reports

    International Nuclear Information System (INIS)

    2000-01-01

    The materials of the 5. All-Russian (international) scientific conference: Physicochemical processes during selection of atoms and molecules, are presented. The conference took place in Zvenigorod, 2-6 October, 2000. A wide range of items connected with uranium enrichment, selection of atoms and molecules by isotopic composition: laser methods, ion cyclotron-resonance method, are discussed. The paper contains the reports about harnessing radionuclides and stable isotopes in medicine and as a means of diagnostics. The results of investigation into modern and advanced technology for isotope separation are outlined. The selection of molecules by means of rectification methods and chemical isotope exchange are discussed [ru

  13. Can Cultural Worldviews Influence Network Composition?

    Science.gov (United States)

    Vaisey, Stephen; Lizardo, Omar

    2010-01-01

    Most sociological research assumes that social network composition shapes individual beliefs. Network theory and research has not adequately considered that internalized cultural worldviews might affect network composition. Drawing on a synthetic, dual-process theory of culture and two waves of nationally-representative panel data, this article…

  14. Internal and Marginal Fit of Modern Indirect Class II Composite Inlays

    Directory of Open Access Journals (Sweden)

    Philipp C. Pott

    2014-06-01

    Full Text Available Introduction: This in vitro study investigates the marginal and internal fit of indirect class II composite restorations. Two different processes for chair-side restorations were compared. In group A, the restorations were fabricated using CAD/CAM technology (Cerec, Sirona, Germany, Bernsheim and in group B they were made by hand (GrandioSO Inlay System, VOCO GmbH, Germany, Cuxhaven. Methods: For a metal tooth with a MOD cavity each 10 restorations were made for groups A and B. For each restoration, a replica of the cement-gap made from light body silicone was produced by placing the restoration into the cavity of the metal tooth. For this purpose, a special restoration-positioning machine was developed. Each replica was sectioned off in the longitudinal axis (L and in the cross axis (C. The thickness of the replicas was measured in both directions, using picture analysis software under a light reflection microscope. To evaluate the fit of the restorations, a special fitting parameter was calculated. Statistical analysis was performed with the t test. Results: The fitting-parameter in group B (L: 97.6µm±73.0µm; C: 71.8µm±46.4µm was significantly lower than that of group A (L: 155.1µm±102.3.0µm; C: 168.2µm±91.9µm (P

  15. Impact resistance of uncoated SiC/SiC composites

    International Nuclear Information System (INIS)

    Bhatt, Ramakrishna T.; Choi, Sung R.; Cosgriff, Laura M.; Fox, Dennis S.; Lee, Kang N.

    2008-01-01

    Two-dimensional woven SiC/SiC composites fabricated by melt infiltration method were impact tested at room temperature and at 1316 deg. C in air using 1.59-mm diameter steel-ball projectiles at velocities ranging from 115 to 400 m/s. The extent of substrate damage with increasing projectile velocity was imaged and analyzed using optical and scanning electron microscopy, and non-destructive evaluation (NDE) methods such as pulsed thermography, and computed tomography. The impacted specimens were tensile tested at room temperature to determine their residual mechanical properties. Results indicate that at 115 m/s projectile velocity, the composite showed no noticeable surface or internal damage and retained its as-fabricated mechanical properties. As the projectile velocity increased above this value, the internal damage increased and mechanical properties degraded. At velocities >300 m/s, the projectile penetrated through the composite, but the composite retained ∼50% of the ultimate tensile strength of the as-fabricated composite and exhibited non-brittle failure. Predominant internal damages are delamination of fiber plies, fiber fracture and matrix shearing

  16. Diagnostic imaging in medicine. 2nd ed

    Energy Technology Data Exchange (ETDEWEB)

    Reba, R C; Goodenough, D J; Davidson, H F

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume.

  17. Effect of internal stress on the strength of PZT ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Tai, Weon Pil; Yun, Yeo Bum; Kim, Song Hee [Kangwon National Univ., Chunchon (Korea, Republic of)

    1996-01-01

    The aim of this study is to investigate the change of bending strength and fatigue strength in the unpolled and poled Pb(Zr, Ti)O ferroelectrics of tetragonal, morphotropic phase boundary (MPB) and rhombohedral composition in terms of internal stress which is measured by XRD method. Before poling treatment the highest bending strength was found in rhombohedral composition. After poling treatment, the bending strength decreased in all compositions but it decreased most remarkably in tetragonal composition. The most prominent decrease of bending strength after poling treatment in tetragonal was attributed to the occurrence of microcracks due to high anisotropic internal stress around grain boundary which was induced by domain alignment toward electric field direction in the microstructure having tetragonality. The decrease of bending strength after poling in MPB and rhombohedral composition was not due to the occurrence of microcracks but to the increase in tensile internal stress perpendicular to the direction of crack propagation by domain alignment. Fatigue strength was higher before poling treatment than after poling treatment for various compositions. 13 refs., 2 tabs., 5 figs.

  18. Advanced probes for edge plasma diagnostics on the CASTOR tokamak

    Czech Academy of Sciences Publication Activity Database

    Stöckel, Jan; Adámek, Jiří; Balan, P.; Hronová-Bilyková, Olena; Brotánková, Jana; Dejarnac, Renaud; Devynck, P.; Ďuran, Ivan; Gunn, J. P.; Hron, Martin; Horáček, Jan; Ionita, C.; Kocan, M.; Martines, E.; Pánek, Radomír; Peleman, P.; Schrittwieser, R.; Van Oost, G.; Žáček, František

    2006-01-01

    Roč. 63, č. 0 (2006), 012001-012002 E-ISSN 1742-6596. [SECOND INTERNATIONAL WORKSHOP AND SUMMER SCHOOL ON PLASMA PHYSICS. Kiten, 03.07.2006-09.07.2006] R&D Projects: GA AV ČR KJB100430504 Institutional research plan: CEZ:AV0Z20430508 Keywords : plasma * tokamak * electric probes * diagnostics Subject RIV: BL - Plasma and Gas Discharge Physics

  19. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J; Haythornthwaite, Jennifer A; Hollender, Lars; Jensen, Rigmor; John, Mike T; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M; Nixdorf, Donald R; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M; Zakrzewska, Joanna; Dworkin, Samuel F

    2014-01-01

    The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project-the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra

  20. Relating faults in diagnostic reasoning with diagnostic errors and patient harm.

    NARCIS (Netherlands)

    Zwaan, L.; Thijs, A.; Wagner, C.; Wal, G. van der; Timmermans, D.R.M.

    2012-01-01

    Purpose: The relationship between faults in diagnostic reasoning, diagnostic errors, and patient harm has hardly been studied. This study examined suboptimal cognitive acts (SCAs; i.e., faults in diagnostic reasoning), related them to the occurrence of diagnostic errors and patient harm, and studied

  1. Nuclear explosion and internal contamination; Explosion nucleaire et contamination interne

    Energy Technology Data Exchange (ETDEWEB)

    Aeberhardt, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    By the study of the conditions of internal contamination due to the radioactive mixture produced by a nuclear explosion, the parts played by the relative weights of the different elements and the mode of expression of the doses are considered. Only the knowledge of the weight composition of the contamination mixture and of its evolution as a function of time can provide the required basis for the study of its metabolism in the organism. The curves which give the composition of the fission product mixture - in number of nuclei - - as a function of time - have been established. These curves are applied to some practical examples, particularly relative to the nature of contamination, radiotoxicity of some elements and assessment of hazards. (author) [French] Etudiant les modalites de la contamination interne par les elements radioactifs apparus lors d'une explosion nucleaire, le role de la 'masse' et le mode d'expression des doses sont envisages. La connaissance de la composition en 'masse' du melange contaminant et de son evolution en fonction du temps peut seule apporter les bases necessaires a l'etude de son comportement dans l'organisme. Les courbes donnant la composition du melange de produits de fission - en nombre de noyaux - - en fonction du temps - ont ete etablies. Quelques applications pratiques, relatives en particulier a la nature de la contamination, a la radiotoxicite de certains elements et a l'evaluation de risque, sont envisagees a titre d'exemple. (auteur)

  2. Hierarchical unilamellar vesicles of controlled compositional heterogeneity.

    Directory of Open Access Journals (Sweden)

    Maik Hadorn

    Full Text Available Eukaryotic life contains hierarchical vesicular architectures (i.e. organelles that are crucial for material production and trafficking, information storage and access, as well as energy production. In order to perform specific tasks, these compartments differ among each other in their membrane composition and their internal cargo and also differ from the cell membrane and the cytosol. Man-made structures that reproduce this nested architecture not only offer a deeper understanding of the functionalities and evolution of organelle-bearing eukaryotic life but also allow the engineering of novel biomimetic technologies. Here, we show the newly developed vesicle-in-water-in-oil emulsion transfer preparation technique to result in giant unilamellar vesicles internally compartmentalized by unilamellar vesicles of different membrane composition and internal cargo, i.e. hierarchical unilamellar vesicles of controlled compositional heterogeneity. The compartmentalized giant unilamellar vesicles were subsequently isolated by a separation step exploiting the heterogeneity of the membrane composition and the encapsulated cargo. Due to the controlled, efficient, and technically straightforward character of the new preparation technique, this study allows the hierarchical fabrication of compartmentalized giant unilamellar vesicles of controlled compositional heterogeneity and will ease the development of eukaryotic cell mimics that resemble their natural templates as well as the fabrication of novel multi-agent drug delivery systems for combination therapies and complex artificial microreactors.

  3. First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay--Lp(a) SRM 2B.

    Science.gov (United States)

    Dati, Francesco; Tate, Jillian R; Marcovina, Santica M; Steinmetz, Armin

    2004-01-01

    Lipoprotein(a) is an important predictor of cardiovascular disease risk. The lack of internationally accepted standardization has impeded the broad application of this lipoprotein in laboratory medicine. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), through its Working Group on Lipoprotein(a) and together with research institutions and several diagnostic companies, have succeeded in developing an international reference material that is intended for the transfer of a lipoprotein(a) concentration to manufacturers' master calibrators. IFCC SRM 2B has recently been accepted by the WHO Expert Committee on Biological Standardization as the 'First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay'. The assigned unitage of 0.1071 nanomoles of lipoprotein(a) per vial is traceable to the consensus reference method for lipoprotein(a) and will enable conformity by diagnostic companies to the European Union's Directive on In vitro Diagnostic Medical Devices for the metrological traceability of calibrator materials.

  4. Diagnostic strategies for urinary tract infections in French general practice.

    Science.gov (United States)

    Kinouani, S; de Lary de Latour, H; Joseph, J-P; Letrilliart, L

    2017-10-01

    We aimed to describe the diagnostic management procedures for detection of urinary tract infections in general practice and their correlated factors. We analyzed data from the ECOGEN study on urinary tract infections, collected in France between November 2011 and April 2012. This national cross-sectional study was carried out in general practices. Data was coded according to the International Classification of Primary Care. A total of 340 consultations or home visits were held for urinary tract infections. The five most frequent diagnostic procedures were (in descending order) clinical examination (67.6%), urine cytobacteriological examination (UCBE) (47.9%), urine dipstick test (15.6%), blood test (8.5%), and imaging (6.5%). No urine dipstick test or UCBE was performed in 43% of cases. Factors correlated with diagnostic procedures were age and gender of patients, annual number of consultations held by family physicians, and duration of consultation. Family physicians did not comply with guidelines on diagnostic management for detection of urinary tract infections. We hypothesized that this non-compliance could be due to the family physicians' environment and characteristics, and to clinical practice guidelines. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. How today's USM diagnostics solve metering problems[Ultrasonic meters

    Energy Technology Data Exchange (ETDEWEB)

    Lansing, John

    2005-07-01

    This paper discusses both basic and advanced diagnostic features of gas ultrasonic meters (USM), and how capabilities built into today's electronics can identify problems that often may not have been identified in the past. It primarily discusses fiscal-quality, multi-path USMs and does not cover issues that may be different with non-fiscal meters. Although USMs basically work the same, the diagnostics for each manufacturer does vary. All brands provide basic features as discussed in AGA 9. However, some provide advanced features that can be used to help identify issues such as blocked flow conditioners and gas compositional errors. This paper is based upon the Daniel USM design and the information presented here may or may not be applicable to other manufacturers. (author) (tk)

  6. Advancing the education in molecular diagnostics: the IFCC-Initiative "Clinical Molecular Biology Curriculum" (C-CMBC); a ten-year experience.

    Science.gov (United States)

    Lianidou, Evi; Ahmad-Nejad, Parviz; Ferreira-Gonzalez, Andrea; Izuhara, Kenji; Cremonesi, Laura; Schroeder, Maria-Eugenia; Richter, Karin; Ferrari, Maurizio; Neumaier, Michael

    2014-09-25

    Molecular techniques are becoming commonplace in the diagnostic laboratory. Their applications influence all major phases of laboratory medicine including predisposition/genetic risk, primary diagnosis, therapy stratification and prognosis. Readily available laboratory hardware and wetware (i.e. consumables and reagents) foster rapid dissemination to countries that are just establishing molecular testing programs. Appropriate skill levels extending beyond the technical procedure are required for analytical and diagnostic proficiency that is mandatory in molecular genetic testing. An international committee (C-CMBC) of the International Federation for Clinical Chemistry (IFCC) was established to disseminate skills in molecular genetic testing in member countries embarking on the respective techniques. We report the ten-year experience with different teaching and workshop formats for beginners in molecular diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Validation of the Gambling Disorder Screening Questionnaire, a self-administered diagnostic questionnaire for gambling disorder based on the DSM-5 criteria.

    Science.gov (United States)

    Villella, Corrado; Pascucci, Marco; de Waure, Chiara; Bellomo, Antonello; Conte, Gianluigi

    2016-01-01

    The DSM-5 has modified the diagnostic criteria for gambling disorder, compared to the fourth edition of the manual; new diagnostic instruments are therefore needed. This study evaluated the psychometric characteristics of the Gambling Disorder Screening Questionnaire (GDSQ), a self-report questionnaire based on the DSM-IV and DSM-5 criteria for Gambling Disorder, measuring its validity, internal consistency, and submitting the questionnaire to a principal components analysis. 71 patients from a gambling disorder outpatient clinic and 70 controls were evaluated with the GDSQ, the South Oaks Gambling Screen (SOGS), and a psychiatric interview. The test showed a good sensibility, specificity, internal consistency, concurrent validity with the SOGS. The exclusion of the “illegal acts” item, and the lowering of the cut-off score to four positive items, as suggested by the DSM-5 criteria, improved the test sensibility and internal consistency. The GDSQ can be considered a useful screening test for Gambling Disorder. Furthermore, this study confirms the improved diagnostic accuracy of the criteria listed in the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders, compared to the previous edition.

  8. Concurrent and predictive evaluation of malnutrition diagnostic measures in hip fracture inpatients: a diagnostic accuracy study.

    Science.gov (United States)

    Bell, J J; Bauer, J D; Capra, S; Pulle, R C

    2014-03-01

    Differences in malnutrition diagnostic measures impact malnutrition prevalence and outcomes data in hip fracture. This study investigated the concurrent and predictive validity of commonly reported malnutrition diagnostic measures in patients admitted to a metropolitan hospital acute hip fracture unit. A prospective, consecutive level II diagnostic accuracy study (n=142; 8 exclusions) including the International Classification of Disease, 10th Revision, Australian Modification (ICD10-AM) protein-energy malnutrition criteria, a body mass index (BMI) Patients were predominantly elderly (median age 83.5, range 50-100 years), female (68%), multimorbid (median five comorbidities), with 15% 4-month mortality. Malnutrition prevalence was lowest when assessed by BMI (13%), followed by MNA-SF (27%), ICD10-AM (48%), albumin (53%) and geriatrician assessment (55%). Agreement between measures was highest between ICD10-AM and geriatrician assessment (κ=0.61) followed by ICD10-AM and MNA-SF measures (κ=0.34). ICD10-AM diagnosed malnutrition was the only measure associated with 48-h mobilisation (35.0 vs 55.3%; P=0.018). Reduced likelihood of home discharge was predicted by ICD-10-AM (20.6 vs 57.1%; P=0.001) and MNA-SF (18.8 vs 47.8%; P=0.035). Bivariate analysis demonstrated ICD10-AM (relative risk (RR)1.2; 1.05-1.42) and MNA-SF (RR1.2; 1.0-1.5) predicted 4-month mortality. When adjusted for age, usual place of residency, comorbidities and time to surgery only ICD-10AM criteria predicted mortality (odds ratio 3.59; 1.10-11.77). Albumin, BMI and geriatrician assessment demonstrated limited concurrent and predictive validity. Malnutrition prevalence in hip fracture varies substantially depending on the diagnostic measure applied. ICD-10AM criteria or the MNA-SF should be considered for the diagnosis of protein-energy malnutrition in frail, multi-morbid hip fracture inpatients.

  9. Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Janvier Sylvestre N’cho

    2016-05-01

    Full Text Available A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.

  10. [Clinic-internal and -external factors of length of hospital stay].

    Science.gov (United States)

    Schariatzadeh, R; Imoberdorf, R; Ballmer, P E

    2011-01-19

    In the context of forthcoming initiation of Diagnosis Related Groups (DRG) in Switzerland, the objective of the study was to find factors having an impact on the inpatient's length of hospital stay. The study was performed on two general-medical wards of the Kantonsspital Winterthur, where all admitted patients were included in the study over two months. The various periods of diagnostic and therapeutic management of the patients and all diagnostic and therapeutic measures plus the arrangements after hospitalization were recorded. The determinants influencing the length of hospital stay were classified in clinic-internal or -external. 124 inpatients entered the study. 91 (73.4%) had a length of hospital stay without delay, whereas 33 (26.6%) patients had an extended length of hospital stay. The cumulative length of hospital stay of all patients was 1314 days, whereof 216 days (16.4%) were caused by delays. 67 days were caused by clinic-internal (5.1%) and 149 days by clinic-external factors (11.3%). Delays were substantially more generated by clinic-internal than -external factors. Clinic-internal factors were mainly weekends with interruption of the diagnostic and therapeutic procedures, dead times waiting for diagnostic results and waiting times for consultations. Clinic-external factors were caused by delayed transfer in nursing homes or rehabilitation institutions, waiting for family members for the backhaul and by indetermination of the patient. Also factors relating to the patients' characteristics had an influence on the length of hospital stay. Summing up, a substantial part of the length of hospital stay was caused by delays. However, the many different clinic-internal factors complicate solutions to lower the length of hospital stay. Moreover, factors that cannot be influenced such as waiting for microbiological results, contribute to extended length of hospital stay. Early scheduling of post-hospital arrangements may lower length of hospital stay

  11. Pengaruh Proporsi Komisaris Independen dan Komposisi Komite Audit terhadap Internal Control

    Directory of Open Access Journals (Sweden)

    Makhdalena Makhdalena

    2015-12-01

    Full Text Available Accounting manipulation that occurred in recent years makes accounting experts to focus on internal control issues. The experts agree that internal control is an important issue through a substance that can be given by the internal control. Internal control can be effective if supported by the proportion of independent commissioners and audit committee composition are adequate. Based on that idea, the researchers interested in conducting research that aims to find out: the influence of the proportion of independent commissioners and audit committee composition of the internal control eithersimultaneously or partially. Research conducted by the survey in 48 listed companies in Jakarta Stock Exchange manufacturing drawn at random from the population. Data used in this study are primary data from the questionnaire and secondary data from the annual report. Data were analyzed using path analysis. The results showed that: the proportion of independent commissioners and audit committee composition has a significant influence on the internal control eithersimultaneously or partially.

  12. Diagnostic uncertainty and recall bias in chronic low back pain.

    Science.gov (United States)

    Serbic, Danijela; Pincus, Tamar

    2014-08-01

    Patients' beliefs about the origin of their pain and their cognitive processing of pain-related information have both been shown to be associated with poorer prognosis in low back pain (LBP), but the relationship between specific beliefs and specific cognitive processes is not known. The aim of this study was to examine the relationship between diagnostic uncertainty and recall bias in 2 groups of chronic LBP patients, those who were certain about their diagnosis and those who believed that their pain was due to an undiagnosed problem. Patients (N=68) endorsed and subsequently recalled pain, illness, depression, and neutral stimuli. They also provided measures of pain, diagnostic status, mood, and disability. Both groups exhibited a recall bias for pain stimuli, but only the group with diagnostic uncertainty also displayed a recall bias for illness-related stimuli. This bias remained after controlling for depression and disability. Sensitivity analyses using grouping by diagnosis/explanation received supported these findings. Higher levels of depression and disability were found in the group with diagnostic uncertainty, but levels of pain intensity did not differ between the groups. Although the methodology does not provide information on causality, the results provide evidence for a relationship between diagnostic uncertainty and recall bias for negative health-related stimuli in chronic LBP patients. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  13. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  14. Laboratory development and testing of spacecraft diagnostics

    Science.gov (United States)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  15. Preliminary results of the analysis of the administered activities in diagnostic studies of nuclear medicine

    International Nuclear Information System (INIS)

    Lopez Bejerano, G.; Sed, L.J.

    2001-01-01

    The worldwide use of Nuclear Medicine diagnostic procedures and the tendency to its increment, infers an important exposure of the population to ionising radiation; it has motivated that the IAEA in the International Basic Safety Standards (BSS), emits recommendations for the establishment of guidance levels of activities administered to the patients in diagnostic procedures. Taking into account the above-mentioned and that in Cuba there exist 20 departments of Nuclear Medicine that in the majority possess equipment with more than 20 years of operation, which influences directly the medical exposure. A survey was designed and applied in 10 of these departments. The survey evaluates the compliance with the BSS requirements, and specifically, the activities administered to the patients in Nuclear Medicine diagnostic procedures are analysed. In the present work the obtained preliminary results of the statistical analysis carried out on the activity values used in Nuclear Medicine departments are presented, and comparisons made for a proposal of guidance levels for the national practice, which is compared with those recommended internationally. (author)

  16. Lipid composition of human meibum

    Directory of Open Access Journals (Sweden)

    R. Schnetler

    2013-12-01

    Full Text Available The structure and function of meibomian gland lipids in the tear film are highly complex. Evidence shows that the precorneal tear film consists of discrete layers: the inner mucin layer, the middle aqueous layer and the outer lipid layer. In this review we focus on the outer, biphasic lipid layer of the tear film which consists of a ‘thick’ outer, non-polar layer  and a ‘thin’ inner, polar layer. We discuss the main composition of the polar and non-polar lipids within meibum (wax esters, cholesteryl esters, mono-, di- and tri-acylglycerols, ceramides, phospholipids  et cetera. We address the composition of meibomian lipids in subjects suffering from various ocular diseases in comparison with the composition in healthy individuals. Further analysis is needed to determine whether a correlation exists between the etiology of various ocular diseases and the fluctuation on the lipids as well as to establish whether or not tear lipid analysis can be used as a diagnostic tool.

  17. International recommendation for a comprehensive neuropathologic workup of epilepsy surgery brain tissue: A consensus Task Force report from the ILAE Commission on Diagnostic Methods.

    Science.gov (United States)

    Blümcke, Ingmar; Aronica, Eleonora; Miyata, Hajime; Sarnat, Harvey B; Thom, Maria; Roessler, Karl; Rydenhag, Bertil; Jehi, Lara; Krsek, Pavel; Wiebe, Samuel; Spreafico, Roberto

    2016-03-01

    Epilepsy surgery is an effective treatment in many patients with drug-resistant focal epilepsies. An early decision for surgical therapy is facilitated by a magnetic resonance imaging (MRI)-visible brain lesion congruent with the electrophysiologically abnormal brain region. Recent advances in the pathologic diagnosis and classification of epileptogenic brain lesions are helpful for clinical correlation, outcome stratification, and patient management. However, application of international consensus classification systems to common epileptic pathologies (e.g., focal cortical dysplasia [FCD] and hippocampal sclerosis [HS]) necessitates standardized protocols for neuropathologic workup of epilepsy surgery specimens. To this end, the Task Force of Neuropathology from the International League Against Epilepsy (ILAE) Commission on Diagnostic Methods developed a consensus standard operational procedure for tissue inspection, distribution, and processing. The aims are to provide a systematic framework for histopathologic workup, meeting minimal standards and maximizing current and future opportunities for morphofunctional correlations and molecular studies for both clinical care and research. Whenever feasible, anatomically intact surgical specimens are desirable to enable systematic analysis in selective hippocampectomies, temporal lobe resections, and lesional or nonlesional neocortical samples. Correct orientation of sample and the sample's relation to neurophysiologically aberrant sites requires good communication between pathology and neurosurgical teams. Systematic tissue sampling of 5-mm slabs along a defined anatomic axis and application of a limited immunohistochemical panel will ensure a reliable differential diagnosis of main pathologies encountered in epilepsy surgery. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  18. Integrating Nursing Diagnostic Concepts into the Medical Entities Dictionary Using the ISO Reference Terminology Model for Nursing Diagnosis

    OpenAIRE

    Hwang, Jee-In; Cimino, James J.; Bakken, Suzanne

    2003-01-01

    Objective: The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED.

  19. Internal Motion Estimation by Internal-external Motion Modeling for Lung Cancer Radiotherapy.

    Science.gov (United States)

    Chen, Haibin; Zhong, Zichun; Yang, Yiwei; Chen, Jiawei; Zhou, Linghong; Zhen, Xin; Gu, Xuejun

    2018-02-27

    The aim of this study is to develop an internal-external correlation model for internal motion estimation for lung cancer radiotherapy. Deformation vector fields that characterize the internal-external motion are obtained by respectively registering the internal organ meshes and external surface meshes from the 4DCT images via a recently developed local topology preserved non-rigid point matching algorithm. A composite matrix is constructed by combing the estimated internal phasic DVFs with external phasic and directional DVFs. Principle component analysis is then applied to the composite matrix to extract principal motion characteristics, and generate model parameters to correlate the internal-external motion. The proposed model is evaluated on a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and 4DCT images from five lung cancer patients. For tumor tracking, the center of mass errors of the tracked tumor are 0.8(±0.5)mm/0.8(±0.4)mm for synthetic data, and 1.3(±1.0)mm/1.2(±1.2)mm for patient data in the intra-fraction/inter-fraction tracking, respectively. For lung tracking, the percent errors of the tracked contours are 0.06(±0.02)/0.07(±0.03) for synthetic data, and 0.06(±0.02)/0.06(±0.02) for patient data in the intra-fraction/inter-fraction tracking, respectively. The extensive validations have demonstrated the effectiveness and reliability of the proposed model in motion tracking for both the tumor and the lung in lung cancer radiotherapy.

  20. Correlation of precursor and product ions in single-stage high resolution mass spectrometry. A tool for detecting diagnostic ions and improving the precursor elemental composition elucidation

    Energy Technology Data Exchange (ETDEWEB)

    Borràs, S. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain); Kaufmann, A., E-mail: anton.kaufmann@klzh.ch [Official Food Control Authority, Fehrenstrasse 15, 8032 Zürich (Switzerland); Companyó, R. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain)

    2013-04-15

    Highlights: ► We are describing a technique to spot ions which are derived from each other. ► Single stage high resolution data is used. ► This “in silicon” technique is compared to conventional precursor scan. ► Some applications for this technique are presented. -- Abstract: Monitoring of common diagnostic fragments is essential for recognizing molecules which are members of a particular compound class. Up to now, unit resolving tandem quadrupole mass spectrometers, operating in the precursor ion scan mode, have been typically used to perform such analysis. By means of high-resolution mass spectrometry (HRMS) a much more sensitive and selective detection can be achieved. However, using a single-stage HRMS instrument, there is no unequivocal link to the corresponding precursor ion, since such instrumentation does not permit a previous precursor selection. Thus, to address this limitation, an in silico approach to locate precursor ions, based on diagnostic fragments, was developed. Implemented as an Excel macro, the algorithm rapidly assembles and surveys exact mass data to provide a list of feasible precursor candidates according to the correlation of the chromatographic peak shape profile and other additional filtering criteria (e.g. neutral losses and isotopes). The macro was tested with two families of veterinary drugs, sulfonamides and penicillins, which are known to yield diagnostic product ions when fragmented. Data sets obtained from different food matrices (fish and liver), both at high and low concentration of the target compounds, were investigated in order to evaluate the capabilities and limitations of the reported approach. Finally, other possible applications of this technique, such as the elucidation of elemental compositions based on product ions and corresponding neutral losses, were also presented and discussed.

  1. Correlation of precursor and product ions in single-stage high resolution mass spectrometry. A tool for detecting diagnostic ions and improving the precursor elemental composition elucidation

    International Nuclear Information System (INIS)

    Borràs, S.; Kaufmann, A.; Companyó, R.

    2013-01-01

    Highlights: ► We are describing a technique to spot ions which are derived from each other. ► Single stage high resolution data is used. ► This “in silicon” technique is compared to conventional precursor scan. ► Some applications for this technique are presented. -- Abstract: Monitoring of common diagnostic fragments is essential for recognizing molecules which are members of a particular compound class. Up to now, unit resolving tandem quadrupole mass spectrometers, operating in the precursor ion scan mode, have been typically used to perform such analysis. By means of high-resolution mass spectrometry (HRMS) a much more sensitive and selective detection can be achieved. However, using a single-stage HRMS instrument, there is no unequivocal link to the corresponding precursor ion, since such instrumentation does not permit a previous precursor selection. Thus, to address this limitation, an in silico approach to locate precursor ions, based on diagnostic fragments, was developed. Implemented as an Excel macro, the algorithm rapidly assembles and surveys exact mass data to provide a list of feasible precursor candidates according to the correlation of the chromatographic peak shape profile and other additional filtering criteria (e.g. neutral losses and isotopes). The macro was tested with two families of veterinary drugs, sulfonamides and penicillins, which are known to yield diagnostic product ions when fragmented. Data sets obtained from different food matrices (fish and liver), both at high and low concentration of the target compounds, were investigated in order to evaluate the capabilities and limitations of the reported approach. Finally, other possible applications of this technique, such as the elucidation of elemental compositions based on product ions and corresponding neutral losses, were also presented and discussed

  2. Is it useful for distinguishing between benign and malignant solid breast masses?: diagnostic criteria of Japan society of ultrasonics in medicine (JSUM)

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Kim, Sun Hee; Chung, Chun Phil [Maryknoll Hospital, Busan (Korea, Republic of)

    1995-10-15

    To evaluate the effectiveness and the most accurate element of the diagnostic criteria of the Japan Society of Ultrasonics in medicine (JSUM, Nov. 1989) for distinguishing between benign and malignant solid breast masses on the US. We analyzed the ultrasonic findings of histopathologically proved 51 fibroadenomas, 12 fibrocystic disease, and 39 breast cancers in relation to the diagnostic criteria of the JSUM (shape, border, boundary echo, internal echo, posterior echo, lateral echo, and depth/width ratio). The number of cases of fibroadenoma, fibrocystic disease, and breast cancer corresponding to the diagnostic criteria was in the shape (26/51, 5/12, 33/39), border (41/51, 9/12, 29/39), boundary echo (48/51, 12/12, 27/39) internal echo (43/51, 9/12, 24/39), posterior echo (32/51, 3/12, 21/39), and lateral shadowing (15/51, 1/12, 35/39). All diagnostic criterias showed statistical significance for differentiation of benign/malignant breast mass on the US (Chi-square test: {rho} < 0.05). The order of accuracy was boundary echo, internal echo, and border. The mean of depth/width ratio was 0.54 {+-} 0.15, 0.52 {+-} 0.12, and 0.69 {+-} 0.21 in fibroadenoma, fibrocystic disease, and breast cancer respectively and it had statistical significance for differentiation of benign/malignant breast mass on the US (ANOVA test: {rho} = 0.0002). The diagnostic criteria of JSUM is effective for differentiation of benign/malignant breast solid masses on the US and has accuracy in the order of boundary echo, internal echo, and border. Depth/width ratio also has statistical significance.

  3. Intelligent DNA-based molecular diagnostics using linked genetic markers

    Energy Technology Data Exchange (ETDEWEB)

    Pathak, D.K.; Perlin, M.W.; Hoffman, E.P.

    1994-12-31

    This paper describes a knowledge-based system for molecular diagnostics, and its application to fully automated diagnosis of X-linked genetic disorders. Molecular diagnostic information is used in clinical practice for determining genetic risks, such as carrier determination and prenatal diagnosis. Initially, blood samples are obtained from related individuals, and PCR amplification is performed. Linkage-based molecular diagnosis then entails three data analysis steps. First, for every individual, the alleles (i.e., DNA composition) are determined at specified chromosomal locations. Second, the flow of genetic material among the individuals is established. Third, the probability that a given individual is either a carrier of the disease or affected by the disease is determined. The current practice is to perform each of these three steps manually, which is costly, time consuming, labor-intensive, and error-prone. As such, the knowledge-intensive data analysis and interpretation supersede the actual experimentation effort as the major bottleneck in molecular diagnostics. By examining the human problem solving for the task, we have designed and implemented a prototype knowledge-based system capable of fully automating linkage-based molecular diagnostics in X-linked genetic disorders, including Duchenne Muscular Dystrophy (DMD). Our system uses knowledge-based interpretation of gel electrophoresis images to determine individual DNA marker labels, a constraint satisfaction search for consistent genetic flow among individuals, and a blackboard-style problem solver for risk assessment. We describe the system`s successful diagnosis of DMD carrier and affected individuals from raw clinical data.

  4. Evaluation of radiation protection in nuclear medicine diagnostic procedures

    International Nuclear Information System (INIS)

    Mohammed, Ezzeldien Mohammed Nour

    2013-05-01

    This study conducted to evaluate the radiation protection in nuclear medicine diagnostic procedures in four nuclear medicine departments in Sudan. The evaluated procedures followed in these departments were in accordance with the standards, International Recommendations and code of practice for radiation protection in nuclear medicine. The evolution included the optimum design for diagnostic nuclear medicine departments, dealing with radioactive sources, quality assurance and quality control, training and responsibilities for radiation worker taking into account economic factors in Sudan. Evaluation of radiation protection procedures in diagnostic investigations was carried out by taken direct measurements of dose rate and the contamination level in some areas where radiation sources, radiation workers and public are involved. Designated questionnaires covered thirteen areas of radiation protection based on inspection check list for nuclear medicine prepared by the International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine (AAPM) were used in the evaluation. This questionnaire has been Filled by Radiation Protection Officer (RPO), nuclear medicine technologist, nuclear medicine specialist in the nuclear medicine departments. Four hospitals, two governmental hospital and two private hospitals, have been assisted, the assessment shows that although the diagnostic nuclear medicine department in Sudan are not applying a fully safety and radiation protection procedures, but the level of radiation dose and the contamination level were found within acceptable limits. The private hospital D scored the higher level of protection (85.25%) while the governmental hospital C scored the lower level of protection (59.02%). Finally, this study stated some recommendations that if implemented could improve the level of radiation protection in nuclear medicine department. One of the most important recommendations is that a proper radiation protection

  5. Size effects on magnetoelectric response of multiferroic composite with inhomogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Y.M. [Shanghai Institute of Applied Mathematics and Mechanics, Shanghai Key Laboratory of Mechanics in Energy Engineering, Department of Mechanics, Shanghai University, Shanghai 200072 (China); Xu, K.Y., E-mail: kyxu@shu.edu.cn [Shanghai Institute of Applied Mathematics and Mechanics, Shanghai Key Laboratory of Mechanics in Energy Engineering, Department of Mechanics, Shanghai University, Shanghai 200072 (China); Chen, T. [Shanghai Institute of Applied Mathematics and Mechanics, Shanghai Key Laboratory of Mechanics in Energy Engineering, Department of Mechanics, Shanghai University, Shanghai 200072 (China); Aifantis, E.C. [Laboratory of Mechanics and Materials (LMM), Aristotle University of Thessaloniki, Thessaloniki GR-54124 (Greece); Michigan Technological University, Houghton, MI 49931 (United States); King Abdulaziz University, Jeddah 21589 (Saudi Arabia); School of Mechanics and Engineering, Southwest Jiaotong University, Chengdu, 610031 (China); International Laboratory for Modern Functional Materials, ITMO University, St. Petersburg 191002 (Russian Federation)

    2015-12-01

    This paper investigates the influence of size effects on the magnetoelectric performance of multiferroic composite with inhomogeneities. Based on a simple model of gradient elasticity for multiferroic materials, the governing equations and boundary conditions are obtained from an energy variational principle. The general formulation is applied to consider an anti-plane problem of multiferroic composites with inhomogeneities. This problem is solved analytically and the effective magnetoelectric coefficient is obtained. The influence of the internal length (grain size or particle size) on the effective magnetoelectric coefficients of piezoelectric/piezomagnetic nanoscale fibrous composite is numerically evaluated and analyzed. The results suggest that with the increase of the internal length of piezoelectric matrix (PZT and BaTiO{sub 3}), the magnetoelectric coefficient increases, but the rate of increase is ratcheting downwards. If the internal length of piezoelectric matrix remains unchanged, the magnetoelectric coefficient will decrease with the increase of internal length scale of piezomagnetic nonfiber (CoFe{sub 2}O{sub 3}). In a composite consisiting of a piezomagnetic matrix (CoFe{sub 2}O{sub 3}) reinforced with piezoelectric nanofibers (BaTiO{sub 3}), an increase of the internal length in the piezomagnetic matrix, results to a decrease of the magnetoelectric coefficient, with the rate of decrease diminishing.

  6. Size effects on magnetoelectric response of multiferroic composite with inhomogeneities

    Science.gov (United States)

    Yue, Y. M.; Xu, K. Y.; Chen, T.; Aifantis, E. C.

    2015-12-01

    This paper investigates the influence of size effects on the magnetoelectric performance of multiferroic composite with inhomogeneities. Based on a simple model of gradient elasticity for multiferroic materials, the governing equations and boundary conditions are obtained from an energy variational principle. The general formulation is applied to consider an anti-plane problem of multiferroic composites with inhomogeneities. This problem is solved analytically and the effective magnetoelectric coefficient is obtained. The influence of the internal length (grain size or particle size) on the effective magnetoelectric coefficients of piezoelectric/piezomagnetic nanoscale fibrous composite is numerically evaluated and analyzed. The results suggest that with the increase of the internal length of piezoelectric matrix (PZT and BaTiO3), the magnetoelectric coefficient increases, but the rate of increase is ratcheting downwards. If the internal length of piezoelectric matrix remains unchanged, the magnetoelectric coefficient will decrease with the increase of internal length scale of piezomagnetic nonfiber (CoFe2O3). In a composite consisiting of a piezomagnetic matrix (CoFe2O3) reinforced with piezoelectric nanofibers (BaTiO3), an increase of the internal length in the piezomagnetic matrix, results to a decrease of the magnetoelectric coefficient, with the rate of decrease diminishing.

  7. Radiation protection of patients in general diagnostic radiology in Lithuania

    International Nuclear Information System (INIS)

    Morkunas, G.; Ziliukas, J.

    2001-01-01

    The situation in control of exposure due to general diagnostic radiological examinations in Lithuania is described. Experience in creation of legal basis for radiation protection, results of measurements of patients' doses and quality control tests of x-ray units are given. The main problems encountered in implementation of international recommendations and requirements of European Medical Exposure Directive are discussed. (author)

  8. Assessing use of a standardized dental diagnostic terminology in an electronic health record

    NARCIS (Netherlands)

    Tokede, O.; White, J.; Stark, P.C.; Vaderhobli, R.; Walji, M.F.; Ramoni, R.; Schoonheim-Klein, M.; Kimmes, N.; Tavares, A.; Kalenderian, E.

    2013-01-01

    Although standardized terminologies such as the International Classification of Diseases have been in use in medicine for over a century, efforts in the dental profession to standardize dental diagnostic terms have not achieved widespread acceptance. To address this gap, a standardized dental

  9. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  10. Tune-Based Halo Diagnostics

    International Nuclear Information System (INIS)

    Cameron, Peter

    2003-01-01

    Tune-based halo diagnostics can be divided into two categories -- diagnostics for halo prevention, and diagnostics for halo measurement. Diagnostics for halo prevention are standard fare in accumulators, synchrotrons, and storage rings, and again can be divided into two categories -- diagnostics to measure the tune distribution (primarily to avoid resonances), and diagnostics to identify instabilities (which will not be discussed here). These diagnostic systems include kicked (coherent) tune measurement, phase-locked loop (PLL) tune measurement, Schottky tune measurement, beam transfer function (BTF) measurements, and measurement of transverse quadrupole mode envelope oscillations. We refer briefly to tune diagnostics used at RHIC and intended for the SNS, and then present experimental results. Tune-based diagnostics for halo measurement (as opposed to prevention) are considerably more difficult. We present one brief example of tune-based halo measurement

  11. A multiscale MD-FE model of diffusion in composite media with internal surface interaction based on numerical homogenization procedure.

    Science.gov (United States)

    Kojic, M; Milosevic, M; Kojic, N; Kim, K; Ferrari, M; Ziemys, A

    2014-02-01

    Mass transport by diffusion within composite materials may depend not only on internal microstructural geometry, but also on the chemical interactions between the transported substance and the material of the microstructure. Retrospectively, there is a gap in methods and theory to connect material microstructure properties with macroscale continuum diffusion characteristics. Here we present a new hierarchical multiscale model for diffusion within composite materials that couples material microstructural geometry and interactions between diffusing particles and the material matrix. This model, which bridges molecular dynamics (MD) and the finite element (FE) method, is employed to construct a continuum diffusion model based on a novel numerical homogenization procedure. The procedure is general and robust for evaluating constitutive material parameters of the continuum model. These parameters include the traditional bulk diffusion coefficients and, additionally, the distances from the solid surface accounting for surface interaction effects. We implemented our models to glucose diffusion through the following two geometrical/material configurations: tightly packed silica nanospheres, and a complex fibrous structure surrounding nanospheres. Then, rhodamine 6G diffusion analysis through an aga-rose gel network was performed, followed by a model validation using our experimental results. The microstructural model, numerical homogenization and continuum model offer a new platform for modeling and predicting mass diffusion through complex biological environment and within composite materials that are used in a wide range of applications, like drug delivery and nanoporous catalysts.

  12. Implementation of a companion diagnostic in the clinical laboratory

    DEFF Research Database (Denmark)

    Mancini, Irene; Pinzani, Pamela; Simi, Lisa

    2015-01-01

    A companion diagnostic test provides information that is essential for the safe and effective use of a corresponding therapeutic product as indicated in the drug instructions. The implementation of a companion diagnostic follows the rules of a molecular test for somatic mutations in a routine...... clinical laboratory environment and needs guidance on practical aspects, including the choice of the proper analytical method and the procedures for internal and external quality controls. Selection of the appropriate assay for detection of genetic alterations depends on several factors: the type...... on restrictions of the method used. In relation to these aspects herein we report an opinion paper of the Working Group Personalized Laboratory Medicine jointly constituted by the European Federation of Laboratory Medicine (EFLM) and by the European Society of Pharmacogenomics and Theranostics (ESPT) using...

  13. Scrutinized with inadequate control and support: Interns' experiences communicating with and writing referrals to hospital radiology departments – A qualitative study

    International Nuclear Information System (INIS)

    Kruse, J.; Lehto, N.; Riklund, K.; Tegner, Y.; Engström, Å.

    2016-01-01

    Introduction: Interns' experiences communicating with and writing referrals to hospital radiology departments are important for patient safety, image quality, and decision-making in the diagnostic process. Understanding roles within the department and in the diagnostic process is important for communication. This study aimed to describe interns' experiences communicating with and writing referrals to their hospital's radiology department. Method: A qualitative study design was used. Data was collected from focus discussions with ten interns in three focus groups in Northern Sweden during 2012. The data were subjected to qualitative content analysis. Results: One theme, “a feeling of being scrutinized and lacking control”, was identified in the final categories. The interns experienced that the radiology department placed high demands on them and desired more diagnostic skills training, resources and feedback. The interns suggested the following improvements: enhanced dialogue and feedback, improved education, handy guidelines, and practice writing referrals. Conclusion: Interns need more feedback from, and dialogue with, members of the Department of Radiology. They also need more knowledge of referral guidelines, appropriateness criteria and more practice to develop their knowledge and skill for writing referrals. They describe feelings of inadequate support and feel scrutinized in demanding work conditions and need more collaboration. They also need more time and more control of radiology outcomes, and they are eager to learn. - Highlights: • Interns' experiences of writing referrals are important in the diagnostic process. • Communication between referents and radiology staff influences patient safety. • Medical interns experience insufficient diagnostic skills. • Interns need more feedback from, and dialogue with radiology staff. • The learning process could benefit from knowledge of the referrers perspective.

  14. An in situ accelerator-based diagnostic for plasma-material interactions science on magnetic fusion devices.

    Science.gov (United States)

    Hartwig, Zachary S; Barnard, Harold S; Lanza, Richard C; Sorbom, Brandon N; Stahle, Peter W; Whyte, Dennis G

    2013-12-01

    This paper presents a novel particle accelerator-based diagnostic that nondestructively measures the evolution of material surface compositions inside magnetic fusion devices. The diagnostic's purpose is to contribute to an integrated understanding of plasma-material interactions in magnetic fusion, which is severely hindered by a dearth of in situ material surface diagnosis. The diagnostic aims to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. Our instrument uses a compact (~1 m), high-current (~1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak at MIT. We control the tokamak magnetic fields--in between plasma shots--to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes ~5 μm into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. An overview of the diagnostic technique, known as accelerator-based in situ materials surveillance (AIMS), and the first AIMS diagnostic on the Alcator C-Mod tokamak is given. Experimental validation is shown to demonstrate that an optimized deuteron beam is injected into the tokamak, that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. The first AIMS analysis, which measures the relative change in deuterium at a single surface location at the end of the Alcator C-Mod FY2012 plasma campaign, is also presented.

  15. Psychologists’ perspectives on the diagnostic classification of mental disorders: Results from the WHO-IUPsyS Global Survey

    Science.gov (United States)

    Evans, Spencer C.; Reed, Geoffrey M.; Roberts, Michael C.; Esparza, Patricia; Watts, Ann D.; Correia, João Mendonça; Ritchie, Pierre; Maj, Mario; Saxena, Shekhar

    2013-01-01

    This study examined psychologists’ views and practices regarding diagnostic classification systems for mental and behavioral disorders so as to inform the development of the ICD-11 by the World Health Organization (WHO). WHO and the International Union of Psychological Science (IUPsyS) conducted a multilingual survey of 2155 psychologists from 23 countries, recruited through their national psychological associations. Sixty percent of global psychologists routinely used a formal classification system, with ICD-10 used most frequently by 51% and DSM-IV by 44%. Psychologists viewed informing treatment decisions and facilitating communication as the most important purposes of classification, and preferred flexible diagnostic guidelines to strict criteria. Clinicians favorably evaluated most diagnostic categories, but identified a number of problematic diagnoses. Substantial percentages reported problems with crosscultural applicability and cultural bias, especially among psychologists outside the USA and Europe. Findings underscore the priority of clinical utility and professional and cultural differences in international psychology. Implications for ICD-11 development and dissemination are discussed. PMID:23750927

  16. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0

  17. Intellectual property considerations for molecular diagnostic development with emphasis on companion diagnostics.

    Science.gov (United States)

    Glorikian, Harry; Warburg, Richard Jeremy; Moore, Kelly; Malinowski, Jennifer

    2018-02-01

    The development of molecular diagnostics is a complex endeavor, with multiple regulatory pathways to consider and numerous approaches to development and commercialization. Companion diagnostics, devices which are "essential for the safe and effective use of a corresponding drug or diagnostic product" (see U.S. Food & Drug Administration, In Vitro Diagnostics - Companion Diagnostics, U.S. Dept. of Health & Human Services(2016), available at https://www.fda.gov/medicaldevices/productsandmedicalprocedures/invitrodiagnostics/ucm407297.htm ) and complementary diagnostics, which are more broadly associated with a class of drug, are becoming increasingly important as integral components of the implementation of precision medicine. Areas covered: The following article will highlight the intellectual property ('IP') considerations pertinent to molecular diagnostics development with special emphasis on companion diagnostics. Expert opinion/commentary Summary: For all molecular diagnostics, intellectual property (IP) concerns are of paramount concern, whether the device will be marketed only in the United States or abroad. Taking steps to protect IP at each stage of product development is critical to optimize profitability of a diagnostic product. Also the legal framework around IP protection of diagnostic technologies has been changing over the previous few years and can be expected to continue to change in the foreseeable near future, thus, a comprehensive IP strategy should take into account the fact that changes in the law can be expected.

  18. Dosimetry in diagnostic and interventional radiology - ICRU and IAEA activities

    International Nuclear Information System (INIS)

    Zoetelief, J.; Pernicka, F.

    2002-01-01

    Full text: Main aims of patient dosimetry in diagnostic and interventional radiology are to determine dosimetric quantities for establishment and use of guidance levels or diagnostic reference levels and for comparative risk assessment. In the latter case, the average doses to the organs and tissues at risk should be assessed. Only limited number of measurements serve to potential risk assessment of the examination and intervention. An additional objective of dosimetry in diagnostic and interventional radiology is the assessment of equipment performance. Ionization chambers are the main devices used for dosimetric measurements in diagnostic and interventional radiology but other devices with special properties are also used. Important examples are thermoluminescent detectors (TLDs) and semiconductor detectors. For most dosemeters used in x-ray medical imaging the desired quantity for calibration of dosemeters is the air kerma free-in-air. Calibrations should be made at appropriate radiation qualities, for which recommendations are available for conventional radiology. It is important that the calibrations are traceable to the international measurement system. The uncertainty of dose measurements in medical x-ray imaging, for comparative risk assessments as well as for quality assurance, should not exceed about 7 per cent in terms of the expanded uncertainty using a coverage factor of 2. The dosimetric approaches in general diagnostic radiology, mammography and computed tomography are slightly different, resulting in application specific dosimetric quantities. Consequently, different protocols for patient dosimetry are available for these different purposes. In general diagnostic radiology, various quantities and terminologies have been used for the specification of dose on the central beam axis at the point where the x-ray beam enters the patient (or a phantom representing the patient). These include the exposure at skin entrance (ESE), the input radiation exposure

  19. Bruxism defined and graded: an international consensus

    NARCIS (Netherlands)

    Lobbezoo, F.; Ahlberg, J.; Glaros, A.G.; Kato, T.; Koyano, K.; Lavigne, G.J.; de Leeuw, R.; Manfredini, D.; Svensson, P.; Winocur, E.

    2013-01-01

    To date, there is no consensus about the definition and diagnostic grading of bruxism. A written consensus discussion was held among an international group of bruxism experts as to formulate a definition of bruxism and to suggest a grading system for its operationalisation. The expert group defined

  20. Improving patient outcomes in fibrous dysplasia/McCune-Albright syndrome: an international multidisciplinary workshop to inform an international partnership.

    Science.gov (United States)

    Boyce, A M; Turner, A; Watts, L; Forestier-Zhang, L; Underhill, A; Pinedo-Villanueva, R; Monsell, F; Tessaris, D; Burren, C; Masi, L; Hamdy, N; Brandi, M L; Chapurlat, R; Collins, M T; Javaid, Muhammad Kassim

    2017-12-01

    To develop consensus on improving the management of patients, we convened an international workshop involving patients, clinicians, and researchers. Key findings included the diagnostic delay and variability in subsequent management with agreement to develop an international natural history study. We now invite other stakeholders to join the partnership. The aim of this study was develop a consensus on how to improve the management of patients with fibrous dysplasia and prioritize areas for research METHODS: An international workshop was held over 3 days involving patients, clinicians, and researchers. Each day had a combination of formal presentations and facilitated discussions that focused on clinical pathways and research. The patient workshop day highlighted the variability of patients' experience in getting a diagnosis, the knowledge of general clinical staff, and understanding long-term outcomes. The research workshop prioritized collaborations that improved understanding of the contemporary natural history of fibrous dysplasia/McCune-Albright syndrome (FD/MAS). The clinical workshop outlined the key issues around diagnostics, assessment of severity, treatment and monitoring of patients. In spite of advances in understanding the genetic and molecular underpinnings of fibrous dysplasia/McCune-Albright syndrome, clinical management remains a challenge. From the workshop, a consensus was reached to create an international, multi-stakeholder partnership to advance research and clinical care in FD/MAS. We invite other stakeholders to join the partnership.

  1. PROSPECTS OF DIAGNOSTICS OF AUTISM SPECTRUM DISORDERS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    O. G. Novoselova

    2014-01-01

    Full Text Available The relevance of a problem of autism spectrum disorder in children and the modern view on etiology and pathogenesis of these states are revealed in the article. Autism classification according to the International classification of diseases of the 10th revision adopted in Russia and important changes of a new classifier of the American psychiatric association concerning autism spectrum disorders are considered. The difficulties connected with diagnostics of autism spectrum disorders in children, autism comorbidity and some other psychiatric nosologies and the necessity of detailed differential diagnostics for a circle of these diseases are mentioned. Autism spectrum disorders are presented from the point of view of clinical genetics, the necessity of medical genetic consultation in diagnosing is proved. Definition of complex and essential autism is given. A number of widespread genetic syndromes with the description of clinical characteristics and molecular genetic mechanisms underlying the pathogenesis is allocated in the group of complex autism. Difficulties of molecular genetic confirmation of the diagnosis are revealed, the algorithm of search of mutations and the short description of methods of diagnostics are given. The efficiency of standard procedure of molecular genetic diagnostics at each stage, according to literary data, is shown in the group of children with essential autism. The opportunities and advantages of a method of the chromosomal micromatrix analysis as one of available modern methods of molecular genetic diagnostics in the group of children with autism spectrum disorders are highlighted on the example of extended microdeletion and microduplicational syndromes.

  2. Parkinson's disease: diagnostic utility of volumetric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wei-Che; Chen, Meng-Hsiang [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); Chou, Kun-Hsien [National Yang-Ming University, Brain Research Center, Taipei (China); Lee, Pei-Lin [National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Tsai, Nai-Wen; Lu, Cheng-Hsien [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Neurology, Kaohsiung (China); Chen, Hsiu-Ling [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Hsu, Ai-Ling [National Taiwan University, Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Huang, Yung-Cheng [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Nuclear Medicine, Kaohsiung (China); Lin, Ching-Po [National Yang-Ming University, Brain Research Center, Taipei (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China)

    2017-04-15

    This paper aims to examine the effectiveness of structural imaging as an aid in the diagnosis of Parkinson's disease (PD). High-resolution T{sub 1}-weighted magnetic resonance imaging was performed in 72 patients with idiopathic PD (mean age, 61.08 years) and 73 healthy subjects (mean age, 58.96 years). The whole brain was parcellated into 95 regions of interest using composite anatomical atlases, and region volumes were calculated. Three diagnostic classifiers were constructed using binary multiple logistic regression modeling: the (i) basal ganglion prior classifier, (ii) data-driven classifier, and (iii) basal ganglion prior/data-driven hybrid classifier. Leave-one-out cross validation was used to unbiasedly evaluate the predictive accuracy of imaging features. Pearson's correlation analysis was further performed to correlate outcome measurement using the best PD classifier with disease severity. Smaller volume in susceptible regions is diagnostic for Parkinson's disease. Compared with the other two classifiers, the basal ganglion prior/data-driven hybrid classifier had the highest diagnostic reliability with a sensitivity of 74%, specificity of 75%, and accuracy of 74%. Furthermore, outcome measurement using this classifier was associated with disease severity. Brain structural volumetric analysis with multiple logistic regression modeling can be a complementary tool for diagnosing PD. (orig.)

  3. Purified natural and recombinant Fel d 1 and cat albumin in in vitro diagnostics for cat allergy

    NARCIS (Netherlands)

    van Ree, R.; van Leeuwen, W. A.; Bulder, I.; Bond, J.; Aalberse, R. C.

    1999-01-01

    Current diagnostics and therapeutics for cat allergy are based on cat epithelial extracts originating from highly variable source materials. This gives rise to several problems: variability of allergen composition, contamination with house dust mite allergens, and potential transfer of pathogenic

  4. Quality control for diagnostic oral microbiology laboratories in European countries

    Directory of Open Access Journals (Sweden)

    Andrew J. Smith

    2011-11-01

    Full Text Available Participation in diagnostic microbiology internal and external quality control (QC processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing clinical oral microbiological samples were identified. All these were recruited to participate into the study and six laboratories from six European countries completed both the online survey and the first QC round. Three additional laboratories participated in the second round. Based on the survey, European oral microbiology laboratories process a significant (mean per laboratory 4,135 number of diagnostic samples from the oral cavity annually. A majority of the laboratories did not participate in any internal or external QC programme and nearly half of the laboratories did not have standard operating procedures for the tests they performed. In both QC rounds, there was a large variation in the results, interpretation and reporting of antibiotic susceptibility testing among the laboratories. In conclusion, the results of this study demonstrate the need for harmonisation of laboratory processing methods and interpretation of results for oral microbiology specimens. The QC rounds highlighted the value of external QC in evaluating the efficacy and safety of processes, materials and methods used in the laboratory. The use of standardised methods is also a prerequisite for multi-centre epidemiological studies that can provide important information on emerging microbes and trends in anti-microbial susceptibility for empirical prescribing in oro-facial infections.

  5. REFLECTIONS ON PRODUCTION INTERNALIZATION AND ITS INTERNATIONAL TRADE IMPLICATIONS

    Directory of Open Access Journals (Sweden)

    CLIPA RALUCA IRINA

    2014-06-01

    Full Text Available Vertically-integrated multinational companies place the different stages of production and marketing chain in different countries, looking for advantages such as low production costs, lower taxes, abundant resources and so on, while benefiting from the advantages of economies of scale, control of supplies or outlets. In fact, this vertical integration of multinational companies has led to the expansion of intra-firm trade and "internalized" operations, thus creating their own markets for the vertically-integrated production. Internationally active firms operate in a way that replaces the different functions of an open market with internal transactions, i.e. intra-firm transactions, whenever internal transaction costs are lower than the open-market ones. The direct consequence over international trade is the increase of intra-firm share of trade flows to one third of world trade, those companies making a suppression of international market segments that act in favour of an internal market. The creation of a multinational market and the enhancement of intra-firm trade have profound quantitative and qualitative implications on the composition, geographic orientation and dynamics of international trade. This paper deals with the issue of production internalization, with an overview of the main contributions made to the theory of internalization, while tackling its relative dimension. However, we intend to highlight the implications of this phenomenon on international trade. The work methodology falls within the range of qualitative approaches: logical argumentation, critical theoretical analysis.

  6. Veterinary Molecular Diagnostics

    NARCIS (Netherlands)

    Roest, H.I.J.; Engelsma, M.Y.; Weesendorp, E.; Bossers, A.; Elbers, A.R.W.

    2017-01-01

    In veterinary molecular diagnostics, samples originating from animals are tested. Developments in the farm animals sector and in our societal attitude towards pet animals have resulted in an increased demand for fast and reliable diagnostic techniques. Molecular diagnostics perfectly matches this

  7. Development of an international code of practice for dosimetry in X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Pernicka, F.; Carlsson, G.A.; Dance, D.R.; DeWerd, L.A.; Kramer, H.-M.; Ng, K.-H.

    2001-01-01

    Medical x-ray examinations contribute greatly to the population dose from man-made radiation sources. There is a need to control this dose and therefore to optimise the design and use of x-ray imaging systems. A key stage in this process is the standardisation of the procedures for dose measurement in the clinic. The Dosimetry and Medical Radiation Physics Section of the IAEA has a number of activities to further advance the standards for x-ray diagnostics. One of these activities is the coordination of a working group to develop a code of practice, which will facilitate the IAEA calibration activities, TLD intercomparisons and audits, educational activities, and technical assistance to Member States. The code of practice will aid in the standardisation of various dosimetric techniques in x-ray diagnostic radiology. The CoP working group has had an initial meeting to review the current status of dosimetry for conventional radiology, fluoroscopy, mammography, computed tomography and dental radiology. The CoP will include the establishment of standards and calibrations at the SSDLs, phantom and patient measurements and procedures for dosimetry in the clinic. (author)

  8. An investigation of structural design methodology for HTGR reactor internals with ceramic materials (Contract research)

    International Nuclear Information System (INIS)

    Sumita, Junya; Shibata, Taiju; Nakagawa, Shigeaki; Iyoku, Tatsuo; Sawa, Kazuhiro

    2008-03-01

    To advance the performance and safety of HTGR, heat-resistant ceramic materials are expected to be used as reactor internals of HTGR. C/C composite and superplastic zirconia are the promising materials for this purpose. In order to use these new materials as reactor internals in HTGR, it is necessary to establish a structure design method to guarantee the structural integrity under environmental and load conditions. Therefore, C/C composite expected as reactor internals of VHTR is focused and an investigation on the structural design method applicable to the C/C composite and a basic applicability of the C/C composite to representative structures of HTGR were carried out in this report. As the results, it is found that the competing risk theory for the strength evaluation of the C/C composite is applicable to design method and C/C composite is expected to be used as reactor internals of HTGR. (author)

  9. National Comorbidity Survey Replication Adolescent Supplement (NCS-A): III. Concordance of DSM-IV/CIDI Diagnoses with Clinical Reassessments

    Science.gov (United States)

    Kessler, Ronald C.; Avenevoli, Shelli; Green, Jennifer; Gruber, Michael J.; Guyer, Margaret; He, Yulei; Jin, Robert; Kaufman, Joan; Sampson, Nancy A.; Zaslavsky, Alan M.; Merikangas, Kathleen R.

    2009-01-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) diagnoses that was based on the World Health Organization's Composite International Diagnostic Interview (CIDI) and implemented in the National comorbidity survey replication adolescent supplement is found to have good individual-level concordance with diagnosis based on blinded…

  10. Sensitivity and specificity of proposed DSM-5 diagnostic criteria for autism spectrum disorder.

    Science.gov (United States)

    McPartland, James C; Reichow, Brian; Volkmar, Fred R

    2012-04-01

    This study evaluated the potential impact of proposed DSM-5 diagnostic criteria for autism spectrum disorder (ASD). The study focused on a sample of 933 participants evaluated during the DSM-IV field trial; 657 carried a clinical diagnosis of an ASD, and 276 were diagnosed with a non-autistic disorder. Sensitivity and specificity for proposed DSM-5 diagnostic criteria were evaluated using field trial symptom checklists as follows: individual field trial checklist items (e.g., nonverbal communication); checklist items grouped together as described by a single DSM-5 symptom (e.g., nonverbal and verbal communication); individual DSM-5 criterion (e.g., social-communicative impairment); and overall diagnostic criteria. When applying proposed DSM-5 diagnostic criteria for ASD, 60.6% (95% confidence interval: 57%-64%) of cases with a clinical diagnosis of an ASD met revised DSM-5 diagnostic criteria for ASD. Overall specificity was high, with 94.9% (95% confidence interval: 92%-97%) of individuals accurately excluded from the spectrum. Sensitivity varied by diagnostic subgroup (autistic disorder = 0.76; Asperger's disorder = 0.25; pervasive developmental disorder-not otherwise specified = 0.28) and cognitive ability (IQ criteria could substantially alter the composition of the autism spectrum. Revised criteria improve specificity but exclude a substantial portion of cognitively able individuals and those with ASDs other than autistic disorder. A more stringent diagnostic rubric holds significant public health ramifications regarding service eligibility and compatibility of historical and future research. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  11. The Bosnian version of the international self-report measure of posttraumatic stress disorder, the Posttraumatic Stress Diagnostic Scale, is reliable and valid in a variety of different adult samples affected by war

    Directory of Open Access Journals (Sweden)

    Rosner Rita

    2005-02-01

    Full Text Available Abstract Background The aim of the present study was to assess the internal consistency and discriminant and convergent validity of the Bosnian version of a self-report measure of posttraumatic stress disorder (PTSD, the Posttraumatic Stress Diagnostic Scale (PTDS. The PTDS yields both a PTSD diagnosis according to the Diagnostic and Statistical Manual of Mental Disorders 4th edition (DSM-IV and a measure of symptom severity. Methods 812 people living in Sarajevo or in Banja Luka in Bosnia-Herzegovina, of whom the majority had experienced a high number of traumatic war events, were administered the PTDS and other measures of trauma-related psychopathology. The psychometric properties of the instrument were assessed using Cronbach's alpha and principal components analysis, and its construct validity was assessed via Spearman correlation coefficients with the other instruments. Results The PTDS and its subscales demonstrated high internal consistency. The principal components revealed by an exploratory analysis are broadly consistent with the DSM-IV subscales except that they reproduce some previously reported difficulties with the "numbing" items from the avoidance subscale. The construct validity of the PTDS was supported by appropriate correlations with other relevant measures of trauma related psychopathology. Conclusion The Bosnian version of the PTDS thus appears to be a time-economic and psychometrically sound measure for screening and assessing current PTSD. This self-report measure awaits further validation by interview methods.

  12. BRIEF REPORT: Beyond Clinical Experience: Features of Data Collection and Interpretation That Contribute to Diagnostic Accuracy

    Science.gov (United States)

    Nendaz, Mathieu R; Gut, Anne M; Perrier, Arnaud; Louis-Simonet, Martine; Blondon-Choa, Katherine; Herrmann, François R; Junod, Alain F; Vu, Nu V

    2006-01-01

    BACKGROUND Clinical experience, features of data collection process, or both, affect diagnostic accuracy, but their respective role is unclear. OBJECTIVE, DESIGN Prospective, observational study, to determine the respective contribution of clinical experience and data collection features to diagnostic accuracy. METHODS Six Internists, 6 second year internal medicine residents, and 6 senior medical students worked up the same 7 cases with a standardized patient. Each encounter was audiotaped and immediately assessed by the subjects who indicated the reasons underlying their data collection. We analyzed the encounters according to diagnostic accuracy, information collected, organ systems explored, diagnoses evaluated, and final decisions made, and we determined predictors of diagnostic accuracy by logistic regression models. RESULTS Several features significantly predicted diagnostic accuracy after correction for clinical experience: early exploration of correct diagnosis (odds ratio [OR] 24.35) or of relevant diagnostic hypotheses (OR 2.22) to frame clinical data collection, larger number of diagnostic hypotheses evaluated (OR 1.08), and collection of relevant clinical data (OR 1.19). CONCLUSION Some features of data collection and interpretation are related to diagnostic accuracy beyond clinical experience and should be explicitly included in clinical training and modeled by clinical teachers. Thoroughness in data collection should not be considered a privileged way to diagnostic success. PMID:17105525

  13. Atomic structures and compositions of internal interfaces. Progress report, September 1, 1991--August 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Seidman, D.N. [Northwestern Univ., Evanston, IL (United States). Dept. of Materials Science and Engineering; Merkle, K.L. [Argonne National Lab., IL (United States)

    1992-03-01

    This research program addresses fundamental questions concerning the relationships between atomic structures and chemical compositions of metal/ceramic heterophase interfaces. The chemical composition profile across a Cu/MgO {l_brace}111{r_brace}-type heterophase interface, produced by the internal oxidation of a Cu(Mg) single phase alloy, is measured via atom-probe field-ion microscopy with a spatial resolution of 0.121 nm; this resolution is equal to the interplanar space of the {l_brace}222{r_brace} MgO planes. In particular, we demonstrate for the first time that the bonding across a Cu/MgO {l_brace}111{r_brace}-type heterophase interface, along a <111> direction common to both the Cu matrix and an MgO precipitate, has the sequence Cu{vert_bar}O{vert_bar}Mg{hor_ellipsis} and not Cu{vert_bar}Mg{vert_bar}O{hor_ellipsis}; this result is achieved without any deconvolution of the experimental data. Before determining this chemical sequence it was established, via high resolution electron microscopy, that the morphology of an MgO precipitate in a Cu matrix is an octahedron faceted on {l_brace}111{r_brace} planes with a cube-on-cube relationship between a precipitate and the matrix. First results are also presented for the Ni/Cr{sub 2}O{sub 4} interface; for this system selected area atom probe microscopy was used to analyze this interface; Cr{sub 2}O{sub 4} precipitates are located in a field-ion microscope tip and a precipitate is brought into the tip region via a highly controlled electropolishing technique.

  14. Is it useful for distinguishing between benign and malignant solid breast masses?: diagnostic criteria of Japan society of ultrasonics in medicine (JSUM)

    International Nuclear Information System (INIS)

    Yoon, Jeong Hee; Kim, Sun Hee; Chung, Chun Phil

    1995-01-01

    To evaluate the effectiveness and the most accurate element of the diagnostic criteria of the Japan Society of Ultrasonics in medicine (JSUM, Nov. 1989) for distinguishing between benign and malignant solid breast masses on the US. We analyzed the ultrasonic findings of histopathologically proved 51 fibroadenomas, 12 fibrocystic disease, and 39 breast cancers in relation to the diagnostic criteria of the JSUM (shape, border, boundary echo, internal echo, posterior echo, lateral echo, and depth/width ratio). The number of cases of fibroadenoma, fibrocystic disease, and breast cancer corresponding to the diagnostic criteria was in the shape (26/51, 5/12, 33/39), border (41/51, 9/12, 29/39), boundary echo (48/51, 12/12, 27/39) internal echo (43/51, 9/12, 24/39), posterior echo (32/51, 3/12, 21/39), and lateral shadowing (15/51, 1/12, 35/39). All diagnostic criterias showed statistical significance for differentiation of benign/malignant breast mass on the US (Chi-square test: ρ < 0.05). The order of accuracy was boundary echo, internal echo, and border. The mean of depth/width ratio was 0.54 ± 0.15, 0.52 ± 0.12, and 0.69 ± 0.21 in fibroadenoma, fibrocystic disease, and breast cancer respectively and it had statistical significance for differentiation of benign/malignant breast mass on the US (ANOVA test: ρ = 0.0002). The diagnostic criteria of JSUM is effective for differentiation of benign/malignant breast solid masses on the US and has accuracy in the order of boundary echo, internal echo, and border. Depth/width ratio also has statistical significance

  15. Organic composition in the dry season rainwater of Guangzhou, China.

    Science.gov (United States)

    Xu, Tao; Song, Zhiguang; Liu, Junfeng; Wang, Cuiping; Wei, Jianrong; Chen, Heng

    2008-02-01

    This paper reports the results from a study of the organic composition of rainwater collected at Tianhe district of Guangzhou city, P.R. China, during the dry season. Several special setups of a pyrex bottle with a glass funnel were used for the collection of the rainwater. Three fractions (aliphatics, PAHs and fatty acids) were separated from the total extracted organic compounds and identified with GC-MS. The molecular diagnostic ratios were utilized for the source reconciliation. The aliphatic hydrocarbon and the biomarkers (triterpanes and steranes) distribution show a characteristic of the petrochemical source in the rainwater samples. The PAHs diagnostic ratios [e.g. MP/P, MPI, Fl/ (Fl + Py)] indicated vehicular emissions. The fatty acids ratios (e.g. C(18:1)/C(18:0) and C(18:2)/C(18:0)) reflect the contribution of cooking emissions, while the higher plant waxes play little part. Moreover, the values of MP/P, MPI, BaA/(BaA + CT) and BeP/(BeP + BaP) reflected the origin of the long-distance transportation to some extent. On the whole, for the dry season rainwater, all molecular diagnostic ratios indicated the complexity of the organic composition of the rain, which have the characteristics of both a local emission contribution and a long-distance transportation contribution.

  16. Applying the Weisbord model as a diagnostic framework for organizational analysis

    Directory of Open Access Journals (Sweden)

    Kontić Ljiljana

    2012-06-01

    Full Text Available This study investigates the effectiveness of the Weisbord's Six Box Model as a diagnostic framework for assessing the factors affecting organizational development. The research area consisted of an international bank which operates in Serbia. In order to identify strengths and weaknesses in the bank, Weisbord's diagnostic questionnaire has been used. Respondents were 137 middle managers in the selected bank. The research results revealed that the bank has strengths in the areas of leadership, relations, purpose and helpful mechanisms. The weaker aspects were organizational structure and rewards. The options for improving structure, as well as rewards system, are suggested. The findings add to the existing literature on organizational diagnosis in cross-cultural contexts.

  17. ICTP-IAEA Workshop on Dense Magnetized Plasma and Plasma Diagnostics: an executive summary

    Science.gov (United States)

    Gribkov, V. A.; Mank, G.; Markowicz, A.; Miklaszewski, R.; Tuniz, C.; Crespo, M. L.

    2011-12-01

    The Workshop on Dense Magnetized Plasma and Plasma Diagnostics was held from 15 to 26 November 2010 at the Abdus Salam International Centre for Theoretical Physics (ICTP), Trieste, Italy. It was attended by 60 participants, including 15 lecturers, 2 tutors and 37 trainees, representing 25 countries.

  18. Comparison of cone - beam computed tomography and intraoral radiography in detection of recurrent caries under composite restorations

    Energy Technology Data Exchange (ETDEWEB)

    Kasraei, Shahin; Shokri, Abbas; Poorolajal, Jalal; Rahmani, Hamid, E-mail: Dr.a.shokri@gmail.com [Hamadan University of Medical Sciences Hamadan (Iran, Islamic Republic of); Khajeh, Samira [Kurdistan University of Medical Sciences, Sanandaj (Iran, Islamic Republic of)

    2017-01-15

    Secondary caries is the most common cause of dental restoration failures. This study aimed to compare the diagnostic accuracy of conventional and digital intraoral radiography and cone beam computed tomography (CBCT) for detection of recurrent caries around composite restorations mesio-occluso-distal (MOD) cavities were prepared using bur on 45 extracted sound human molar teeth. The teeth were divided into 3 groups. In the control group, cavities were restored with composite resin after etching and bonding (n=15). In Group 2, 500-μm thick wax was placed over the buccal, lingual and gingival walls and the cavities were restored with composite resin. Group 3 specimens were subjected to pH cycling and artificial caries were created on the buccal, lingual and gingival walls. The cavities were restored with composite. Conventional and digital photo-stimulable phosphor (PSP; Optime) radiographs and two CBCTs images (NewTom 3G and Cranex 3D) were obtained from them. Presence or absence of caries in the cavity walls was assessed on these images. Data were analyzed using Kappa statistic. The diagnostic accuracy of CBCT was significantly higher than that of digital and conventional intraoral radiography (p<0.05). The accuracy was 0.83, 0.78, 0.55 and 0.49 for CBCT Cranex 3D, CBCT NewTom 3G, conventional and digital intraoral radiography, respectively. CBCT has a higher diagnostic accuracy than digital and conventional intraoral radiography for detection of secondary caries around composite restorations. (author)

  19. Comparison of cone - beam computed tomography and intraoral radiography in detection of recurrent caries under composite restorations

    International Nuclear Information System (INIS)

    Kasraei, Shahin; Shokri, Abbas; Poorolajal, Jalal; Rahmani, Hamid; Khajeh, Samira

    2017-01-01

    Secondary caries is the most common cause of dental restoration failures. This study aimed to compare the diagnostic accuracy of conventional and digital intraoral radiography and cone beam computed tomography (CBCT) for detection of recurrent caries around composite restorations mesio-occluso-distal (MOD) cavities were prepared using bur on 45 extracted sound human molar teeth. The teeth were divided into 3 groups. In the control group, cavities were restored with composite resin after etching and bonding (n=15). In Group 2, 500-μm thick wax was placed over the buccal, lingual and gingival walls and the cavities were restored with composite resin. Group 3 specimens were subjected to pH cycling and artificial caries were created on the buccal, lingual and gingival walls. The cavities were restored with composite. Conventional and digital photo-stimulable phosphor (PSP; Optime) radiographs and two CBCTs images (NewTom 3G and Cranex 3D) were obtained from them. Presence or absence of caries in the cavity walls was assessed on these images. Data were analyzed using Kappa statistic. The diagnostic accuracy of CBCT was significantly higher than that of digital and conventional intraoral radiography (p<0.05). The accuracy was 0.83, 0.78, 0.55 and 0.49 for CBCT Cranex 3D, CBCT NewTom 3G, conventional and digital intraoral radiography, respectively. CBCT has a higher diagnostic accuracy than digital and conventional intraoral radiography for detection of secondary caries around composite restorations. (author)

  20. Evaluation of the accuracy of diagnostic scales for a syndrome in Chinese medicine in the absence of a gold standard.

    Science.gov (United States)

    Wang, Xiao Nan; Zhou, Vanessa; Liu, Qiang; Gao, Ying; Zhou, Xiao-Hua

    2016-01-01

    The concept of syndromes (zhengs) is unique to Chinese medicine (CM) and difficult to measure. Expert consensus is used as a gold standard to identify zhengs and evaluate the accuracy of existing diagnostic scales for zhengs. But, the use of expert consensus as a gold standard is problematic because the diagnosis of zhengs by expert consensus is not 100 % accurate. This study aimed to evaluate the accuracy of standardized diagnostic scales for a syndrome zhengs in the absence of a gold standard, with application to internal wind (nei feng) syndrome in ischemic stroke patients. A total of 204 participants (age 41-84 years) with ischemic stroke were assessed by the stroke syndrome differentiation diagnostic criterion (SSDC), ischemic stroke TCM syndrome diagnostic scale (ISDS), and expert syndrome differentiation (ESD). The diagnostic tests and data collection process were conducted over a 10-month period (February 2008 to November 2008) in 10 hospitals across nine cities in China. The Bayesian method was used to estimate the accuracy of the SSDC, ISDS, and ESD. For internal wind syndrome, the estimated sensitivities and specificities of the SSDC, ISDS, and ESD without use of a gold standard were respectively: [Formula: see text], [Formula: see text]; [Formula: see text], [Formula: see text]; and [Formula: see text], [Formula: see text]. After adjusting for imperfect gold standard bias, we found that both the sensitivity and specificity of the ISDS were higher than those of the SSDC for diagnosis of internal wind syndrome in ischemic stroke patients.

  1. Exhaust Gas Temperature Measurements in Diagnostics of Turbocharged Marine Internal Combustion Engines Part II Dynamic Measurements

    Directory of Open Access Journals (Sweden)

    Korczewski Zbigniew

    2016-01-01

    Full Text Available The second part of the article describes the technology of marine engine diagnostics making use of dynamic measurements of the exhaust gas temperature. Little-known achievements of Prof. S. Rutkowski of the Naval College in Gdynia (now: Polish Naval Academy in this area are presented. A novel approach is proposed which consists in the use of the measured exhaust gas temperature dynamics for qualitative and quantitative assessment of the enthalpy flux of successive pressure pulses of the exhaust gas supplying the marine engine turbocompressor. General design assumptions are presented for the measuring and diagnostic system which makes use of a sheathed thermocouple installed in the engine exhaust gas manifold. The corrected thermal inertia of the thermocouple enables to reproduce a real time-history of exhaust gas temperature changes.

  2. Episodic intrusion, internal differentiation, and hydrothermal alteration of the miocene tatoosh intrusive suite south of Mount Rainier, Washington

    Science.gov (United States)

    du Bray, E.A.; Bacon, C.R.; John, D.A.; Wooden, J.L.; Mazdab, F.K.

    2011-01-01

    The Miocene Tatoosh intrusive suite south of Mount Rainier is composed of three broadly granodioritic plutons that are manifestations of ancestral Cascades arc magmatism. Tatoosh intrusive suite plutons have individually diagnostic characteristics, including texture, mineralogy, and geochemistry, and apparently lack internal contacts. New ion-microprobe U-Pb zircon ages indicate crystallization of the Stevens pluton ca. 19.2 Ma, Reflection-Pyramid pluton ca. 18.5 Ma, and Nisqually pluton ca. 17.5 Ma. The Stevens pluton includes rare, statistically distinct ca. 20.1 Ma zircon antecrysts. Wide-ranging zircon rare earth element (REE), Hf, U, and Th concentrations suggest late crystallization from variably evolved residual liquids. Zircon Eu/Eu*-Hf covariation is distinct for each of the Reflection-Pyramid, Nisqually, and Stevens plutons. Although most Tatoosh intrusive suite rocks have been affected by weak hydrothermal alteration, and sparse mineralized veins cut some of these rocks, significant base or precious metal mineralization is absent. At the time of shallow emplacement, each of these magma bodies was largely homogeneous in bulk composition and petrographic features, but, prior to final solidification, each of the Tatoosh intrusive suite plutons developed internal compositional variation. Geochemical and petrographic trends within each pluton are most consistent with differential loss of residual melt, possibly represented by late aplite dikes or erupted as rhyolite, from crystal-rich magma. Crystal-rich magma that formed each pluton evidently accumulated in reservoirs below the present level of exposure and then intruded to a shallow depth. Assembled by episodic intrusion, the Tatoosh intrusive suite may be representative of midsized composite plutonic complexes beneath arc volcanoes. ?? 2011 Geological Society of America.

  3. Finding NMO: The Evolving Diagnostic Criteria of Neuromyelitis Optica

    Science.gov (United States)

    Bennett, Jeffrey L.

    2016-01-01

    Neuromyelitis optica (NMO) is an autoimmune demyelinating disorder of the central nervous system (CNS) with predilection for the optic nerves and spinal cord. Since its emergence in the medical literature in the late 1800’s, the diagnostic criteria for NMO has slowly evolved from the simultaneous presentation of neurologic and ophthalmic signs to a relapsing or monophasic CNS disorder defined by clinical, neuroimaging, and laboratory criteria. Due to the identification of a specific autoantibody response against the astrocyte water channel aquaporin-4 (AQP4) in the vast majority of affected individuals, the clinical spectrum of NMO has greatly expanded necessitating the development of new international criteria for the diagnosis of NMO spectrum disorder (NMOSD). The routine application of new diagnostic criteria for NMOSD in clinical practice will be critical for future refinement and correlation with therapeutic outcomes. PMID:27529327

  4. A Primer on Receiver Operating Characteristic Analysis and Diagnostic Efficiency Statistics for Pediatric Psychology: We Are Ready to ROC

    Science.gov (United States)

    2014-01-01

    Objective To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Method Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Results Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores 30 had a diagnostic likelihood ratio of 7.4. Conclusions This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses. PMID:23965298

  5. A critical view of transgender health care in Germany: Psychopathologizing gender identity - Symptom of 'disordered' psychiatric/psychological diagnostics?

    Science.gov (United States)

    Güldenring, Annette

    2015-01-01

    After explaining the essential trans* terminology, I offer a short historical overview of the way health care has dealt with the subject of gender, trans* and health in different times. In the third section, I compare the world's most important diagnostic manuals, namely the International statistical classification of diseases and related health problems (ICD) and the Diagnostic and statistical manual of mental disorders (DSM), i.e. their criteria for 'gender identity disorders' (ICD-10) and 'gender dysphoria' (DSM-5). The fourth section branch out the factors which influence every diagnostic conception - of no matter whom - in the health care system. The last section discusses the implications resulting from this diagnostic dilemma for the health situation of gender nonconforming people.

  6. Research Reports from the First Pre-ICME Satellite Conference on Diagnostic and Prescriptive Mathematics (Monash University, Melbourne, Australia, August 21-22, 1984).

    Science.gov (United States)

    Blane, Dudley, Ed.

    Provided are the papers presented at a conference which served as an international forum on diagnostic and prescriptive mathematics education. They are: (1) "The Evolution of the Research Council for Diagnostic and Prescriptive Mathematics" by Robert Underhill; (2) "The Interaction of Knowledge and Cognitive Processes in Diagnosis…

  7. A multiscale MD–FE model of diffusion in composite media with internal surface interaction based on numerical homogenization procedure

    Science.gov (United States)

    Kojic, M.; Milosevic, M.; Kojic, N.; Kim, K.; Ferrari, M.; Ziemys, A.

    2014-01-01

    Mass transport by diffusion within composite materials may depend not only on internal microstructural geometry, but also on the chemical interactions between the transported substance and the material of the microstructure. Retrospectively, there is a gap in methods and theory to connect material microstructure properties with macroscale continuum diffusion characteristics. Here we present a new hierarchical multiscale model for diffusion within composite materials that couples material microstructural geometry and interactions between diffusing particles and the material matrix. This model, which bridges molecular dynamics (MD) and the finite element (FE) method, is employed to construct a continuum diffusion model based on a novel numerical homogenization procedure. The procedure is general and robust for evaluating constitutive material parameters of the continuum model. These parameters include the traditional bulk diffusion coefficients and, additionally, the distances from the solid surface accounting for surface interaction effects. We implemented our models to glucose diffusion through the following two geometrical/material configurations: tightly packed silica nanospheres, and a complex fibrous structure surrounding nanospheres. Then, rhodamine 6G diffusion analysis through an aga-rose gel network was performed, followed by a model validation using our experimental results. The microstructural model, numerical homogenization and continuum model offer a new platform for modeling and predicting mass diffusion through complex biological environment and within composite materials that are used in a wide range of applications, like drug delivery and nanoporous catalysts. PMID:24578582

  8. Second International Diagnostic Accuracy Study for the Serological Detection of West Nile Virus Infection

    OpenAIRE

    Sanchini, Andrea; Donoso-Mantke, Oliver; Papa, Anna; Sambri, Vittorio; Teichmann, Anette; Niedrig, Matthias

    2013-01-01

    Background: In recent decades, sporadic cases and outbreaks in humans of West Nile virus (WNV) infection have increased. Serological diagnosis of WNV infection can be performed by enzyme-linked immunosorbent assay (ELISA), immunofluorescence assay (IFA) neutralization test (NT) and by hemagglutination-inhibition assay. The aim of this study is to collect updated information regarding the performance accuracy of WNV serological diagnostics. Methodology/Principal findings: In 2011, the E...

  9. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  10. Advanced composite structures. [metal matrix composites - structural design criteria for spacecraft construction materials

    Science.gov (United States)

    1974-01-01

    A monograph is presented which establishes structural design criteria and recommends practices to ensure the design of sound composite structures, including composite-reinforced metal structures. (It does not discuss design criteria for fiber-glass composites and such advanced composite materials as beryllium wire or sapphire whiskers in a matrix material.) Although the criteria were developed for aircraft applications, they are general enough to be applicable to space vehicles and missiles as well. The monograph covers four broad areas: (1) materials, (2) design, (3) fracture control, and (4) design verification. The materials portion deals with such subjects as material system design, material design levels, and material characterization. The design portion includes panel, shell, and joint design, applied loads, internal loads, design factors, reliability, and maintainability. Fracture control includes such items as stress concentrations, service-life philosophy, and the management plan for control of fracture-related aspects of structural design using composite materials. Design verification discusses ways to prove flightworthiness.

  11. ICTP-IAEA Workshop on Dense Magnetized Plasma and Plasma Diagnostics: an executive summary

    International Nuclear Information System (INIS)

    Gribkov, V.A.; Mank, G.; Markowicz, A.; Miklaszewski, R.; Tuniz, C.; Crespo, M.L.

    2011-01-01

    The Workshop on Dense Magnetized Plasma and Plasma Diagnostics was held from 15 to 26 November 2010 at the Abdus Salam International Centre for Theoretical Physics (ICTP), Trieste, Italy. It was attended by 60 participants, including 15 lecturers, 2 tutors and 37 trainees, representing 25 countries. (conference report)

  12. Interfacial reactions in intermetallic matrix composites

    International Nuclear Information System (INIS)

    Cantrell, L.B.; Clevenger, E.M.; Perepezko, J.H.

    1993-01-01

    The thermal stability of advanced composites is dominated by the behavior of internal interfaces. Analysis of these internal interfaces often involves consideration of at least ternary order phase equilibria. Limited thermodynamic data exists for ternary and higher order systems. However, a combined approach based upon the use of binary data to estimate ternary phase equilibria and experimentally determined reaction pathways is effective in the analysis of interface reactions in composite systems. In blended powder samples, thermal analysis was used to find possible reaction temperatures, while X-ray analysis, EDS, and EPMA of diffusion couples were used to assess interdiffusion reaction pathways. The approach is illustrated by compatibility studies between TiAl and TiSi 2 at 1,100 C, and in-situ reactions between B 4 C and TiAl at 1300 C where multiple reaction sequences have been analyzed to provide guidance for the design of in-situ reaction processing of composites

  13. Post-graduate training in imaging diagnostics, nuclear medicine and radiotherapy for radiographers

    International Nuclear Information System (INIS)

    Petkova, E.; Velkova, K.; Shangova, M.; Karidova, S.

    2006-01-01

    Full text: The application of new technologies in imaging diagnostics, as well as the use of digital processing and storing of information, has increased the quality and scope of imaging diagnostics. The potentials of therapeutic methods connected with imaging diagnostics and nuclear medicine, interventional therapeutic procedures (dilatation, embolism, stent, etc.), basins with radio-pharmaceuticals, etc., are constantly increasing. The constant training of radiographers in working with the new, advanced image-diagnostic equipment has become an established international practice in the process of training the human resources of the imaging-diagnostic departments and centers. Objectives: 1. Investigating the potentials of post-graduate training for monitoring the dynamics in the development of the principles, methods and techniques in imaging diagnostics; 2. The attitude of radiographers towards post-graduate training. Systematic approach and critical analysis of published data and mathematical-statistical methods with regard to the need of post-graduate training. The processed data of the survey on the necessity for post-graduate training conducted among 3rd year students in the last 3 years - 75 % consider post-graduate training mandatory, 11% deem it necessary, and 14% have no opinion on the issue; and among the working radiographers in the last 3 years the results are as follows: mandatory - 91%, necessary - 7%, no opinion - 2%. The improvement and advances in imaging diagnostic equipment and apparatuses have considerably outstripped the professional training of radiographers. The key word in the race for knowledge is constant learning and training, which can successfully be achieved within the framework of post-graduate training

  14. Diagnostic standards for dopaminergic augmentation of restless legs syndrome: report from a World Association of Sleep Medicine-International Restless Legs Syndrome Study Group consensus conference at the Max Planck Institute.

    Science.gov (United States)

    García-Borreguero, Diego; Allen, Richard P; Kohnen, Ralf; Högl, Birgit; Trenkwalder, Claudia; Oertel, Wolfgang; Hening, Wayne A; Paulus, Walter; Rye, David; Walters, Arthur; Winkelmann, Juliane; Earley, Christopher J

    2007-08-01

    Augmentation of symptom severity is the main complication of dopaminergic treatment of restless legs syndrome (RLS). The current article reports on the considerations of augmentation that were made during a European Restless Legs Syndrome Study Group (EURLSSG)-sponsored Consensus Conference in April 2006 at the Max Planck Institute (MPI) in Munich, Germany, the conclusions of which were endorsed by the International RLS Study Group (IRLSSG) and the World Association of Sleep Medicine (WASM). The Consensus Conference sought to develop a better understanding of augmentation and generate a better operational definition for its clinical identification. Current concepts of the pathophysiology, clinical features, and therapy of RLS augmentation were evaluated by subgroups who presented a summary of their findings for general consideration and discussion. Recent data indicating sensitivity and specificity of augmentation features for identification of augmentation were also evaluated. The diagnostic criteria of augmentation developed at the National Institutes of Health (NIH) conference in 2002 were reviewed in light of current data and theoretical understanding of augmentation. The diagnostic value and criteria for each of the accepted features of augmentation were considered by the group. A consensus was then developed for a revised statement of the diagnostic criteria for augmentation. Five major diagnostic features of augmentation were identified: usual time of RLS symptom onset each day, number of body parts with RLS symptoms, latency to symptoms at rest, severity of the symptoms when they occur, and effects of dopaminergic medication on symptoms. The quantitative data available relating the time of RLS onset and the presence of other features indicated optimal augmentation criteria of either a 4-h advance in usual starting time for RLS symptoms or a combination of the occurrence of other features. A paradoxical response to changes in medication dose also indicates

  15. International epidemiological studies on HIV, HCV and STI

    NARCIS (Netherlands)

    van der Helm, J.J.

    2014-01-01

    This thesis comprises international epidemiological studies on HIV, Hepatitis C (HCV) and sexually transmitted infections (STI) and the evaluation of STI diagnostic tests with the ultimate goal to decrease spread and disease burden of these infections. The main conclusions are: 1. Without the use of

  16. Poor Validity of the DSM-IV Schizoid Personality Disorder Construct as a Diagnostic Category.

    Science.gov (United States)

    Hummelen, Benjamin; Pedersen, Geir; Wilberg, Theresa; Karterud, Sigmund

    2015-06-01

    This study sought to evaluate the construct validity of schizoid personality disorder (SZPD) by investigating a sample of 2,619 patients from the Norwegian Network of Personality-Focused Treatment Programs by a variety of statistical techniques. Nineteen patients (0.7%) reached the diagnostic threshold of SZPD. Results from the factor analyses indicated that SZPD consists of three factors: social detachment, withdrawal, and restricted affectivity/ anhedonia. Overall, internal consistency and diagnostic efficiency were poor and best for the criteria that belong to the social detachment factor. These findings pose serious questions about the clinical utility of SZPD as a diagnostic category. On the other hand, the three factors were in concordance with findings from previous studies and with the trait model for personality disorders in DSM-5, supporting the validity of SZPD as a dimensional construct. The authors recommend that SZPD should be deleted as a diagnostic category in future editions of DSM-5.

  17. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  18. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  19. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Directory of Open Access Journals (Sweden)

    LuisJoaquín Garcia-Lopez

    Full Text Available Social Anxiety Disorder (SAD is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain.The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1 and clinical sample (study 2.Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls. Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency.Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  20. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T A

    2015-01-01

    Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  1. Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer

    Science.gov (United States)

    Campuzano-Zuluaga, Germán; Álvarez-Sánchez, Gonzalo; Escobar-Gallo, Gloria Elcy; Valencia-Zuluaga, Luz Marina; Ríos-Orrego, Alexandra Marcela; Pabón-Vidal, Adriana; Miranda-Arboleda, Andrés Felipe; Blair-Trujillo, Silvia; Campuzano-Maya, Germán

    2010-01-01

    Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into Plasmodium vivax, P. falciparum, and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For P. vivax, two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For P. falciparum, two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis. PMID:20207864

  2. Establishment of an international nuclear safety body

    International Nuclear Information System (INIS)

    Rosen, M.

    1983-01-01

    During the past year there has been increasing interest in the establishment of new international mechanisms for developing a more uniform approach to nuclear safety. The tasks, organizational nature and affiliation, composition and structure, and financial support of an international nuclear safety body are discussed in the article

  3. Modular beam diagnostics instrument design for Cyclotrons

    International Nuclear Information System (INIS)

    Chaddha, N.; Bhole, R.B.; Sahoo, S.; Nandy, P.P.; Pal, S.

    2012-01-01

    The Cyclotrons at VECC, Kolkata i.e. Room Temperature Cyclotron (RTC) and Superconducting Cyclotron (SCC) comprise of internal and external Beam Diagnostic systems. These systems provide the beam developer with position, intensity, beam profile, a visual impression of the size and shape of ion beam, and operational control over diagnostic components like 3-finger probe, Beam Viewer probe, Deflector probe, Faraday cup, X-Y slit, Beam viewer etc. Automation of these components was initially done using customised modules for individual sub-system. An expansion of this facility and various levels of complexity demand modular design to cater easy modification and upgradation. The overall requirements are analysed and modular cards are developed based on basic functionalities like valve operation, probe/slit/viewer control, position read-out, Interlock, aperture control of beam line and communication. A 32-bit Advanced RISC Machine (ARM) based card with embedded EPICS is chosen as the master controller and FPGA/microcontroller is used for functional modules. The paper gives a comprehensive description of all modules and their integration with the control system. (author)

  4. International patenting in ophthalmology: An analysis of its structure and relevance for the development of drugs and diagnostics

    Directory of Open Access Journals (Sweden)

    Hermann AM Mucke

    2008-10-01

    Full Text Available Hermann AM Mucke, Peter Mucke, Eva MuckeHM Pharma Consultancy, Vienna, AustriaAbstract: While investigative ophthalmologists access peer-reviewed journals as part of their daily routine, and while they regularly visit scientific congresses, they rarely peruse patent documents as an information source. Among the reasons for this negligence are the incompatibility of patent search algorithms with those known from journal databases, a legalistic and frequently redundant language, and misconceptions about the nature of the patenting system. Here we present key data and analyses from the ophthalmology module of a patent database system that we are developing to address some of these problems. We show that international patent applications consistently reflect developer interest in the ocular drug and diagnostics field; that they are technically focused lead indicators of developments that frequently feature in peer-reviewed patenting only much later; and that patenting targets are well aligned with the unmet therapeutic needs of populations in industrialized countries. Most applications (74%–78% in years since 2006 are supported with experimental data, and most (on average, 80%–90% faced at least one objection to patentability during their initial stage of examination. In contrast to the peer-reviewed scenery that is highly diverse, the corresponding patenting arena shows a pronounced focus on the United States.Keywords: ophthalmology, eye diseases, iontophoresis, intellectual property, patents as topic, bibliographic databases

  5. Diagnostic reference levels in digital mammography: a systematic review

    International Nuclear Information System (INIS)

    Suleiman, Moayyad E.; Brennan, Patrick C.; McEntee, Mark F.

    2015-01-01

    This study aims to review the literature on existing diagnostic reference levels (DRLs) in digital mammography and methodologies for establishing them. To this end, a systematic search through Medline, Cinahl, Web of Science, Scopus and Google scholar was conducted using search terms extracted from three terms: DRLs, digital mammography and breast screen. The search resulted in 1539 articles of which 22 were included after a screening process. Relevant data from the included studies were summarised and analysed. Differences were found in the methods utilised to establish DRLs including test subjects types, protocols followed, conversion factors employed, breast compressed thicknesses and percentile values adopted. These differences complicate comparison of DRLs among countries; hence, an internationally accepted protocol would be valuable so that international comparisons can be made. (authors)

  6. Diagnostics for a coal-fired MHD retrofit of an existing power station

    Energy Technology Data Exchange (ETDEWEB)

    Cook, R L; Shepard, W S [Mississippi State Univ. (USA). Diagnostic Instrumentation and Analysis Lab.

    1990-01-01

    MHD flows represent one of the most severe environments encountered by gasdynamic diagnostics. Special state-of-the-art techniques and instrumentation systems are required to monitor and collect data for the MHD components, and these diagnostic systems must operate under very severe environmental and magnetic field conditions. The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University has developed, and is continuing to develop, advanced optical diagnostic techniques and instrumentation systems to provide nonintrusive, remote real-time measurements and to operate successfully in the industrial-like environment of a large-scale MHD retrofit power station. Such diagnostic instrumentation can provide the information to completely evaluate the performance of individual components, as well as, the entire power plant. It is essential to determine as much detail as possible about the various component operations in an MHD retrofit system so that a commercial plant design can be optimized quickly. This paper discusses the instrumentation systems which DIAL proposed for an MHD retrofit of an existing power station. Instruments which have been making measurements on the U.S. MHD test facilities for several years are presented, along with instruments which will be available within two years. Parameters to be measured along with location and frequency are discussed in detail. These parameters include electron density, electrical conductivity, K-atom density, gas temperature, gas velocity, temperature and velocity profiles, gas composition, and particle size, number, density and distrib00000

  7. Real-time remote diagnostic monitoring test-bed in JET

    International Nuclear Information System (INIS)

    Castro, R.; Kneupner, K.; Vega, J.; De Arcas, G.; Lopez, J.M.; Purahoo, K.; Murari, A.; Fonseca, A.; Pereira, A.; Portas, A.

    2010-01-01

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. Its main functionality is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there is one data generator, which is the acquisition equipment associated with the reflectometer diagnostic that generates data and status information. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on JAVA Web Start technology has been used. There are three interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of an architecture, flexible enough to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements. Finally, the third result is a secure system, taking into account internal networks and firewalls aspects of JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to monitor diagnostics in real-time, and enabling the integration of this service into the EFDA Federation (Castro et al., 2008 ).

  8. Real-time remote diagnostic monitoring test-bed in JET

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R., E-mail: rodrigo.castro@ciemat.e [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); Kneupner, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Vega, J. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); De Arcas, G.; Lopez, J.M. [Universidad Politecnica de Madrid, Grupo I2A2, Madrid (Spain); Purahoo, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Murari, A. [Associazione EURATOM-ENEA per la Fusione, Consorzio RFX, 4-35127 Padova (Italy); Fonseca, A. [Associacao EURATOM/IST, Lisbon (Portugal); Pereira, A.; Portas, A. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)

    2010-07-15

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. Its main functionality is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there is one data generator, which is the acquisition equipment associated with the reflectometer diagnostic that generates data and status information. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on JAVA Web Start technology has been used. There are three interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of an architecture, flexible enough to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements. Finally, the third result is a secure system, taking into account internal networks and firewalls aspects of JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to monitor diagnostics in real-time, and enabling the integration of this service into the EFDA Federation (Castro et al., 2008 ).

  9. Multifunctional composites aircraft applications in Finmeccanica - Some examples

    Science.gov (United States)

    Iannone, Michele

    2016-05-01

    Some examples of multifunctional composite materials presently developed by Finmeccanica are described. The basic concept is to modify the material/structure by adding a further function to the structural basic one. The described examples refer to: improvement of processability; self-diagnostic capability; improvement of the allowables, acting on reduction of the knock down factor required to take in account the environmental ageing effects.

  10. Field-testing of the ICHD-3 beta diagnostic criteria for classical trigeminal neuralgia

    DEFF Research Database (Denmark)

    Maarbjerg, Stine; Sørensen, Morten Togo; Gozalov, Aydin

    2015-01-01

    INTRODUCTION: We aimed to field-test the beta version of the third edition of the International Classification of Headache Disorders (ICHD-3 beta) diagnostic criteria for classical trigeminal neuralgia (TN). The proposed beta draft of the 11th version of the International Classification of Diseases...... (ICD-11 beta) is almost exclusively based on the ICHD-3 beta classification structure although slightly abbreviated. We compared sensitivity and specificity to ICHD-2 criteria, and evaluated the needs for revision. METHODS: Clinical characteristics were systematically and prospectively collected from...

  11. Agreement and Diagnostic Performance of FITNESSGRAM®, International Obesity Task Force, and Hungarian National BMI Standards

    Science.gov (United States)

    Laurson, Kelly R.; Welk, Gregory J.; Marton, Orsolya; Kaj, Mónika; Csányi, Tamás

    2015-01-01

    Purpose: This study examined agreement between all 3 standards (as well as relative diagnostic associations with metabolic syndrome) using a representative sample of youth from the Hungarian National Youth Fitness Study. Method: Body mass index (BMI) was assessed in a field sample of 2,352 adolescents (ages 10-18.5 years) and metabolic syndrome…

  12. Support structure concept for integration of ITER diagnostics in the port cell

    Energy Technology Data Exchange (ETDEWEB)

    Udintsev, V.S., E-mail: victor.udintsev@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Portalès, M.; Giacomin, T.; Darcourt, O.; Direz, M.-F.; Martins, J.P.; Penot, C.; Arumugam, A.P.; Drevon, J.-M.; Friconneau, J.P.; Levesy, B.; Maquet, P.; Patel, K.M.; Pitcher, C.S. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Popova, E. [Russian Federation Domestic Agency, Moscow (Russian Federation); Proust, M. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Ronden, D.M.S. [DIFFER, Nieuwegein (Netherlands); Walker, C.I.; Walsh, M.J.; Watts, C. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France)

    2013-10-15

    Highlights: ► An interspace support structure to support the diagnostic systems from the back of the upper and equatorial port plugs to the biological shield plug. ► Port cell support structures are foreseen to handle the equipment in the port cell. ► Both ISS and PCSS will be supported by means of RH rail system. ► The structures will be positioned with a certain tolerance. ► The proposed concepts are found to fulfil the needs for support of the diagnostics in ITER. -- Abstract: Development of the diagnostics for ITER tokamak, which is presently under construction by several international partners at Cadarache in France, is a major challenge because of severe environment, strict engineering requirements, and the need for high reliability in the measurements. The diagnostic systems in the upper, equatorial and lower port cells on ITER are designed to be integrated within the interspace and port cell support structures. These structures are interfacing with remote handling rail system for the cask operations, thus facilitating the removal and installation of the diagnostics in the port and hence minimizing time for working close to the tokamak. In this paper, the challenges associated with the integration of the diagnostics in the port interspace and port cell, as well as their solutions will be addressed and presented. The interspace and the port cell support structures, as well as their interfaces with the biological shield, will be discussed.

  13. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  14. Internal friction and longitudinal modulus behaviour of multiferroic PbZr0.52Ti0.48O3+Ni0.93Co0.02Mn0.05Fe1.95O4-δ particulate composites

    International Nuclear Information System (INIS)

    Ramana, M Venkata; Sreenivasulu, G; Reddy, N Ramamanohar; Kumar, K V Siva; Murty, B S; Murthy, V R K

    2007-01-01

    Multiferroic particulate composites with composition xNi 0.93 Co 0.02 Mn 0.5 Fe 1.95 O 4-δ + (1 - x)PbZr 0.52 Ti 0.48 O 3 where the molar fraction x varies as 0, 0.1, 0.2, 0.3, 0.4 and 0.5 were prepared by the conventional ceramic method. The presence of two phases was confirmed by x-ray diffraction and scanning electron microscopy. The temperature variation of the longitudinal modulus (L) and the internal friction (Q -1 ) of these particulate composites at 104.387 kHz was studied in the wide temperature range 30-420 deg. C. The temperature variation of the longitudinal modulus (L) in each composition of these particulate composites showed two abrupt minima. One minimum coincided with the ferroelectric-paraelectric Curie transition temperature (θ E ) and the other with the ferrimagnetic-paramagnetic Curie transition (θ M ) temperature. The internal friction (Q -1 ) measurements also showed two sharp peaks in each composition corresponding to those temperatures where the minima were noticed in the temperature variation of the longitudinal modulus behaviour. The Curie transition temperature of pure ferrite was found to be 560 deg. C. Addition of 10% of ferrite to ferroelectric in a magnetoelectric (ME) composite resulted in a 360 deg. C fall in θ M and with a further increase in ferrite content the θ M variation was found to be very nominal. However, no significant ferroelectric Curie transition temperature shift could be noticed. This behaviour is explained in the light of structural phase transitions in these multiferroic particulate composites. These ME composites were prepared with a view to using them as ME sensors and transducers

  15. The German version of the Posttraumatic Stress Disorder Checklist for DSM-5 (PCL-5): psychometric properties and diagnostic utility.

    Science.gov (United States)

    Krüger-Gottschalk, Antje; Knaevelsrud, Christine; Rau, Heinrich; Dyer, Anne; Schäfer, Ingo; Schellong, Julia; Ehring, Thomas

    2017-11-28

    The Posttraumatic Stress Disorder (PTSD) Checklist (PCL, now PCL-5) has recently been revised to reflect the new diagnostic criteria of the disorder. A clinical sample of trauma-exposed individuals (N = 352) was assessed with the Clinician Administered PTSD Scale for DSM-5 (CAPS-5) and the PCL-5. Internal consistencies and test-retest reliability were computed. To investigate diagnostic accuracy, we calculated receiver operating curves. Confirmatory factor analyses (CFA) were performed to analyze the structural validity. Results showed high internal consistency (α = .95), high test-retest reliability (r = .91) and a high correlation with the total severity score of the CAPS-5, r = .77. In addition, the recommended cutoff of 33 on the PCL-5 showed high diagnostic accuracy when compared to the diagnosis established by the CAPS-5. CFAs comparing the DSM-5 model with alternative models (the three-factor solution, the dysphoria, anhedonia, externalizing behavior and hybrid model) to account for the structural validity of the PCL-5 remained inconclusive. Overall, the findings show that the German PCL-5 is a reliable instrument with good diagnostic accuracy. However, more research evaluating the underlying factor structure is needed.

  16. Grain Size and Parameter Recovery with TIMSS and the General Diagnostic Model

    Science.gov (United States)

    Skaggs, Gary; Wilkins, Jesse L. M.; Hein, Serge F.

    2016-01-01

    The purpose of this study was to explore the degree of grain size of the attributes and the sample sizes that can support accurate parameter recovery with the General Diagnostic Model (GDM) for a large-scale international assessment. In this resampling study, bootstrap samples were obtained from the 2003 Grade 8 TIMSS in Mathematics at varying…

  17. Screening for HIV-related PTSD: Sensitivity and specificity of the 17 ...

    African Journals Online (AJOL)

    This study assessed the sensitivity and specificity of the 17-item Post traumatic Stress Diagnostic Scale (PDS), a self-report instrument, in the detection of HIVrelated PTSD. An adapted version of the PTSD module of the Composite International Diagnostic Interview (CIDI) served as the gold standard. Method: 85 HIV-positive ...

  18. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  19. Oxidation and corrosion of silicon-based ceramics and composites

    International Nuclear Information System (INIS)

    Jacobson, N.S.; Fox, D.S.; Smialek, J.L.

    1997-01-01

    Silica scales exhibit slow growth rates and a low activation energy. Thus silica-protected materials are attractive high temperature structural materials for their potentially excellent oxidation resistance and well-documented high temperature strength. This review focuses on silicon carbide, silicon nitride, and composites of these materials. It is divided into four parts: (i) Fundamental oxidation mechanisms, (ii) Special properties of silica scales, (iii) Protective coatings, and (iv) Internal oxidation behavior of composites. While the fundamental oxidation mechanism of SiC is understood, there are still many questions regarding the oxidation mechanism of Si 3 N 4 . Silica scales exhibit many unique properties as compared to chromia and alumina. These include slower growth rates, SiO(g) formation, sensitivity to water vapor and impurities, and dissolution by basic molten salts. Protective coatings can limit the deleterious effects. The fourth area-internal oxidation of fibers and fiber coatings in composites-has limited the application of these novel materials. Strategies for understanding and limiting this internal oxidation are discussed. (orig.)

  20. Component vibration of VVER-reactors - diagnostics and modelling

    International Nuclear Information System (INIS)

    Altstadt, E.; Scheffler, M.; Weiss, F.-P.

    1995-01-01

    Flow induced vibrations of reactor pressure vessel (RPV) internals (control element and core barrel motions) at VVER-440 reactors have led to the development of dedicated methods for on-line monitoring. These methods need a certain developed stage of the faults to be detected. To achieve a real sensitive early detection of mechanical faults of RPV internals, a theoretical vibration model was developed based on finite elements. The model comprises the whole primary circuit including the steam generators (SG). By means of that model all eigenfrequencies up to 30 Hz and the corresponding mode shapes were calculated for the normal vibration behaviour. Moreover the shift of eigenfrequencies and of amplitudes due to the degradation or to the failure of internal clamping and spring elements could be investigated, showing that a recognition of such degradations even inside the RPV is possible by pure excore vibration measurements. A true diagnostic, that is the identification of the failed component, might become possible because different faults influence different and well separated eigenfrequencies. (author)

  1. Safety of Medical Diagnostic Ultrasound

    International Nuclear Information System (INIS)

    Breyer, B.

    1998-01-01

    Large numbers of people (both sick and healthy) are routinely exposed to ultrasound waves. We shall discuss wave parameters and scanner properties that are relevant to the safety aspect. This includes central pulse frequency, pulse length, intensity (ISPTA and others), focusing, pulse repetition frequency, pulse pressure, etc. Since the transmitted ultrasound power has steadily been increasing during the last two decades, the problems are becoming more serious with time. Doppler methods have gained importance and 'popularity, which additionally increases ultrasound power requirements since the reflectivity of red blood cells is so small that the backscattered pressure is about 100 times less than that from soft tissue structures in the body. Main mechanisms that can potentially present hazard are heating and cavitation. The basic parameter used to assess thermal hazard is ISPTA and the optimal predictor of cavitation hazard is the peak rarefractional pressure. The hazard of heating-up can be summarized in saying that temperatures up to 38.5 o C are safe, while temperatures above 41 o C are definitely not. Care must be taken to stay within the safe zone. However, there does not exist a confirmed report of any type of hazardous effects on humans using intensities presently applied in diagnostic ultrasound scanners. Taking this into account, various international bodies have put limits to the application of ultrasound, which is best summarized in the FDA (USA) regulation that diagnostic apparatus may have an output of maximally 720 mW/cm 2 (derated) provided thermal and mechanical properties are indicated (onscreen) by properly defined Thermal Indices (TI) and Mechanical Index (MI). These aspects shall be discussed in some detail. We shall give the rules for the operator to apply ultrasound with minimal hazard. The general conclusion is that diagnostic ultrasound, as presently known, may be used whenever a qualified expert expects essential medical benefit for the

  2. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  3. Optical diagnostics of streamer discharges in atmospheric gases

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan

    2014-01-01

    Roč. 47, č. 46 (2014), s. 463001-463001 ISSN 0022-3727 R&D Projects: GA ČR(CZ) GAP205/12/1709 Grant - others:Rada Programu interní podpory projektů mezinárodní spolupráce AV ČR(CZ) M100431201 Program:M Institutional support: RVO:61389021 Keywords : streamer * optical diagnostics * laser-induced fluorescence * LIF * TALIF * red-sprite Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.721, year: 2014 http://iopscience.iop.org/0022-3727/47/46/463001/pdf/0022-3727_47_46_463001.pdf

  4. Material toughness, internal structure, and caldera-collapse frequencies in basaltic and composite edifices

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, Agust [Department of Earth Sciences, Queen' s Building, Royal Holloway University of London, Egham TW20 OEX (United Kingdom)], E-mail: a.gudmundsson@es.rhul.ac.uk

    2008-10-01

    Formation of, and slip on existing, collapse calderas is much more common in basaltic edifices than in composite edifices. I suggest that this difference is partly due to the composite edifices being tougher and more resistant to ring-fault formation than a basaltic edifices. The high matieral toughness of composite edifices is related to their being composed of rock layers with widely different elastic properties, the elastic mismatch promoting deflection and/or arrest of potential ring faults at layer contacts.

  5. PANCREATIC DIABETES TYPE 2 IN CHILDREN AND ADOLESCENTS: INTERNATIONAL RECOMMENDATIONS

    Directory of Open Access Journals (Sweden)

    O.V. Vasyukova

    2009-01-01

    Full Text Available Violent growth of type 2 diabetes mellitus (DM morbidity in children and adolescents is spread all around the world. Peculiarities of DM type 2 in this age group are: absence of determined diagnostic criteria, difficulty of differential diagnosis with DM type 1, early development of complications. International Society of Pediatric and Adolescent Diabetes propose Guideline of DM type 2 management, which consider main questions of diagnostics, treatment and prophylaxis of this disease. The agent of choice for treatment of DM type 2 in children upwards 10 years is metformin.Key words: children, diabetes mellitus type 2, diagnostics, treatment.(Voprosy sovremennoi pediatrii — Current Pediatrics. 2009;8(2:49-53

  6. Composite risers for deep-water offshore technology: Problems and prospects. 1. Metal-composite riser

    Science.gov (United States)

    Beyle, A. I.; Gustafson, C. G.; Kulakov, V. L.; Tarnopol'skii, Yu. M.

    1997-09-01

    Prospects for the application of advanced composites in the offshore technology of oil production are considered. The use of composites in vertical pipelines-risers seems to be the most efficient. The operating loads are studied and the attendant problems are formulated. A comparative analysis of the characteristics of metal, composite, and metal-composite deep-water risers is presented. A technique is developed for designing multilayered risers, taking into account the action of internal and external pressures, gravity, and the axial tensile force created by tensioners, as well as the residual technological stresses due to the difference in coefficients of thermal expansion, physical-chemical shrinkage, and force winding. Numerical estimations are given for a two-layered riser with an inner metal layer of steel, titanium, or aluminum alloys and a composite layer of glass- or carbon-fiber plastics formed by circumferential winding. It is shown that the technological stresses substantially affect the characteristics of the riser.

  7. Diagnostic test for prenatal identification of Down's syndrome and mental retardation and gene therapy therefor

    Science.gov (United States)

    Smith, Desmond J.; Rubin, Edward M.

    2000-01-01

    A a diagnostic test useful for prenatal identification of Down syndrome and mental retardation. A method for gene therapy for correction and treatment of Down syndrome. DYRK gene involved in the ability to learn. A method for diagnosing Down's syndrome and mental retardation and an assay therefor. A pharmaceutical composition for treatment of Down's syndrome mental retardation.

  8. Fetal dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Faulkner, K.

    2002-01-01

    Diagnostic radiology examinations are frequently performed in all countries because of the benefit that the patient derives from the resultant diagnosis. Given that so many examinations are performed it is inevitable that there will be occasions when the planned exposure of a woman who is known to be pregnant is contemplated. In these circumstances, there must be rigorous justification of the examination and the procedure itself must be optimised as well. Radiation risks from fetal irradiation are well established. These risks fall into three categories: 1) a cancer induction risk (mainly leukaemia); 2) hereditary effects (as the fetus is a potential parent); 3) a risk of serious mental retardation (if the fetus is exposed in the critical 8-15 weeks period when the forebrain is being developed). Risk factors for these effects have been reviewed by the International Commission on Radiological Protection. Special rules apply to the radiology of women who are or who may be pregnant. These rules have been developed to avoid he unintended irradiation of the fetus. These rules have been variously referred to as the 10-day rule and the 28-day rules, in which radiology of potentially pregnant women is restricted to the first 10 or 28 days following menstruation. It is apparent that the advice provided by national bodies varies, as different rules apply internationally, due presumably to a lack of an international consensus on the subject. The advice from the National Radiological Protection Board, the College of Radiographers and the Royal College of Radiologists applies in the United Kingdom. In summary, the advice is that women of child bearing age are asked before a diagnostic radiology examination in which the pelvis is in, or near, the primary beam are asked if they are, or may be, pregnant. If pregnancy can be excluded then the examination can proceed. If it is likely that the patient is pregnant, then the proposed examination must undergo rigorous justification. If

  9. Comet 67P/Churyumov-Gerasimenko Surface Composition as a Playground for Radiative Transfer Modeling and Laboratory Measurements: an international ISSI team

    Science.gov (United States)

    Stephan, K.; Ciarniello, M.; Beck, P.; Filacchione, G.; Moroz, L.; Pilorget, C.; Pommerol, A.; Quirico, E.; Raponi, A.; Schröder, S.; Kappel, D.; Vinogradoff, V.; Istiqomah, I.; Rousseau, B.

    2017-12-01

    Remote sensing observations at visible-infrared (VIS-IR) wavelengths of the nucleus of comet 67P/Churyumov-Gerasimenko performed by VIRTIS (Coradini et al., 2007) aboard the Rosetta mission have revealed a surface ubiquitously covered by low-albedo material (Capaccioni et al., 2015; Ciarniello et al., 2015), characterized by the presence of refractory and semi-volatile organics and dark opaque phases (Capaccioni et al., 2015; Quirico et al., 2016). However, a quantitative determination of the physical properties (grain size, porosity) and chemical composition of the surface regolith, from spectrophotometric analysis, is still missing. This subject will be investigated within an international team hosted by ISSI (International Space Science Institute), taking advantage of available and dedicated laboratory reflectance measurements on cometary analogue samples and radiative transfer models (Hapke, 2012; Shkuratov et al., 1999; Monte Carlo ray-tracing), applied to Rosetta spectrophotometric observations of the nucleus. The convergence between models and measurements will allow us to provide a thorough characterization of 67P/Churyumov-Gerasimenko surface. At the same time, the comparison of theoretical predictions with results from laboratory reflectance spectroscopy on powders of analog materials give us the possibility to constrain the capability of the models to characterize their composition (endmember abundances and mixing modalities) and physical properties. We report about the state of the art of laboratory reflectance spectroscopy and spectral modeling applied to 67P/Churyumov-Gerasimenko VIS-IR spectrum as well as preliminary results of the team activity and planned future work. Acknowledgements: the team thanks ISSI-Switzerland for the logistic and financial support.

  10. Effect of Bovine Serum Albumin Treatment on the Aging and Activity of Antibodies in Paper Diagnostics

    Science.gov (United States)

    Huang, Ziwei; Gengenbach, Thomas; Tian, Junfei; Shen, Wei; Garnier, Gil

    2018-05-01

    Paper and cellulosic films are used in many designs of low-cost diagnostics such as paper-based blood grouping devices. A major issue limiting their commercialization is the short stability of the functional biomolecules. To address this problem, the effect of relative humidity (RH) and bovine serum albumin (BSA) on the antibody bioactivity and the surface chemical composition of a paper blood typing biodiagnostic were studied. An IgM blood typing antibody was physisorbed from solution onto paper - with or without BSA pretreatment, and aged for periods up to 9 weeks at room temperature and under different RH conditions. The blood typing efficiency of the antibodies and the substrate surface chemical composition were analyzed by image analysis and X-ray photoelectron spectroscopy (XPS), respectively. This study tests two hypotheses. The first is that the hydroxyl groups in paper promote antibody denaturation on paper; the second hypothesis is that proteins such as BSA can partially block the hydroxyl groups with paper, thus preserving antibody bioactivity. Results show that high RH is detrimental to antibody longevity on paper, while BSA can block hydroxyl groups and prolong antibody longevity by almost an order of magnitude – regardless of humidity. This study opens up new engineering concepts to develop robust and marketable paper diagnostics. The simplest is to store paper and antibody based diagnostics in moisture proof packages.

  11. Preparation of ring-shaped composite bonded magnets with continuously controlled anisotropy distribution for internal space

    International Nuclear Information System (INIS)

    Yamashita, F; Yamada, O; Ohya, S; Kobayashi, O; Nakano, M; Fukunaga, H

    2010-01-01

    We have already reported an advanced method for producing a radially-anisotropic rare earth composite bonded magnet with continuously controlled direction of anisotropy. The magnet has been applied to an inner rotor as a practical usage. In this study, the outstanding preparation method was adopted into the preparation of a magnet applied for an outer rotor. An optimized condition of extrusion and compaction at an elevated temperature could be obtained. In addition, a low pressure configuration to the ring-shaped magnet from plural preformed magnets was carried out, which had specific distribution of magnetic anisotropy for internal space for a small motor, by using self recoverability based on the viscous deformation without an alignment field. No deterioration of magnetic properties was detected through the process even if those magnets were miniaturized. Resultantly, the (BH) max of a ring-shaped magnet with the continuously controlled direction of magnetic anisotropy attained the value of 186 kJ/m 3 , and we obtained sine-wave magnetic anisotropy distribution, even if those magnets were miniaturized.

  12. Facial Nerve Schwannoma of the Cerebellopontine Angle: A Diagnostic Challenge

    OpenAIRE

    Lassaletta, Luis; Roda, José María; Frutos, Remedios; Patrón, Mercedes; Gavilán, Javier

    2002-01-01

    Facial nerve schwannomas are rare lesions that may involve any segment of the facial nerve. Because of their rarity and the lack of a consistent clinical and radiological pattern, facial nerve schwannomas located at the cerebellopontine angle (CPA) and internal auditory canal (IAC) represent a diagnostic and therapeutic challenge for clinicians. In this report, a case of a CPA/IAC facial nerve schwannoma is presented. Contemporary diagnosis and management of this rare lesion are analyzed.

  13. Design Development of a Combined Deployment and Pointing System for the International Space Station Neutron Star Interior Composition Explorer Telescope

    Science.gov (United States)

    Budinoff, Jason; Gendreau, Keith; Arzoumanian, Zaven; Baker, Charles; Berning, Robert; Colangelo, TOdd; Holzinger, John; Lewis, Jesse; Liu, Alice; Mitchell, Alissa; hide

    2016-01-01

    This paper describes the design of a unique suite of mechanisms that make up the Deployment and Pointing System (DAPS) for the Neutron Star Interior Composition Explorer (NICER/SEXTANT) instrument, an X-Ray telescope, which will be mounted on the International Space Station (ISS). The DAPS system uses four stepper motor actuators to deploy the telescope box, latch it in the deployed position, and allow it to track sky targets. The DAPS gimbal architecture provides full-hemisphere coverage, and is fully re-stowable. The compact design of the mechanism allowed the majority of total instrument volume to be used for science. Override features allow DAPS to be stowed by ISS robotics.

  14. Diagnostic Validity of Combining History Elements and Physical Examination Tests for Traumatic and Degenerative Symptomatic Meniscal Tears.

    Science.gov (United States)

    Décary, Simon; Fallaha, Michel; Frémont, Pierre; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Feldman, Debbie E; Sylvestre, Marie-Pierre; Vendittoli, Pascal-André; Desmeules, François

    2017-10-27

    The current approach to the clinical diagnosis of traumatic and degenerative symptomatic meniscal tears (SMTs) proposes combining history elements and physical examination tests without systematic prescription of imaging investigations, yet the evidence to support this diagnostic approach is scarce. To assess the validity of diagnostic clusters combining history elements and physical examination tests to diagnose or exclude traumatic and degenerative SMT compared with other knee disorders. Prospective diagnostic accuracy study. Patients were recruited from 2 orthopedic clinics, 2 family medicine clinics, and from a university community. A total of 279 consecutive patients who underwent consultation for a new knee complaint. Each patient was assessed independently by 2 evaluators. History elements and standardized physical examination tests performed by a physiotherapist were compared with the reference standard: an expert physicians' composite diagnosis including a clinical examination and confirmatory magnetic resonance imaging. Participating expert physicians were orthopedic surgeons (n = 3) or sport medicine physicians (n = 2). Penalized logistic regression (least absolute shrinkage and selection operator) was used to identify history elements and physical examination tests associated with the diagnosis of SMT and recursive partitioning was used to develop diagnostic clusters. Diagnostic accuracy measures were calculated including sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios (LR+/-) with associated 95% confidence intervals (CIs). Eighty patients had a diagnosis of SMT (28.7%), including 35 traumatic tears and 45 degenerative tears. The combination a history of trauma during a pivot, medial knee pain location, and a positive medial joint line tenderness test was able to diagnose (LR+ = 8.9; 95% CI 6.1-13.1) or exclude (LR- = 0.10; 95% CI 0.03-0.28) a traumatic SMT. Combining a history of

  15. Radionuclide diagnostics in St. Petersburg: сurrent status and development challenges

    Directory of Open Access Journals (Sweden)

    I. A. Zvonova

    2015-01-01

    Full Text Available This work aims at radionuclide diagnostics analyses in the Russian Federation city of St. Petersburg over 2005–2014. The study covers trends and development challenges , availability of radionuclide diagnostics for population needs, exposure doses for patients.This work aims at radionuclide diagnostics analyses in the Russian Federation city of St. Petersburg over 2005–2014. The study covers trends and development challenges , availability of radionuclide diagnostics for population needs, exposure doses for patients.Materials and methods. The radionuclide diagnostics temporal and structural changes’ analysis was based on Federal state statistical observation forms No.3-DOZ for St. Petersburg and on the results of radionuclide diagnostics subdivision surveys with radiology physicians’ questionnaires on the amount and composition of conducted examinations, dosages of introduced radioactivity of radiopharmaceticals and patients’ doses.The results. Since the end of 1990s until 2012 the amount of radionuclide diagnostics procedures had been steadily reducing. 74000 procedures were conducted in 2005 and 35500 in 2012. The number of radionuclide diagnostics procedures per one thousand residents reduced from 16 to 7.2. Both indicators slightly grew in 2013. In 2014 the total number of radiodiagnostic proceduress amounted up to 42000 and 8.2 tests per 1000 residents. Since 2011 the diagnostic equipment was upgraded. Four medical institutions received SPECT (single photon emission computed tomography or SPECT/CT, two new PET ( positron emission tomographs – centers were set up, three medical institutions had acquired positron emission tomographs (PET and are conducting PET – diagnostics receiving radiofarmaceuticals from external PET – center. At the same time one a third of radiodiagnostic units still has been operating obsolete and depreciated equipment dating back to 1980–1990 .Inspection results indicated that St. Petersburg

  16. High-resolution three-dimensional compositional imaging by double-pulse laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Schiavo, C.; Grifoni, E.; Legnaioli, S.; Lorenzetti, G.; Poggialini, F.; Pagnotta, S.; Palleschi, V.; Menichetti, L.

    2016-01-01

    In this paper we present a new instrument specifically realized for high-resolution three-dimensional compositional analysis and mapping of materials. The instrument is based on the coupling of a Double-Pulse Laser-Induced Breakdown Spectroscopy (LIBS) instrument with an optical microscope. The compositional mapping of the samples is obtained by scanning the laser beam across the surface of the sample, while the in depth analysis is performed by sending multiple laser pulses on the same point. Depths of analysis of several tens of microns can be obtained. The instrument presented has definite advantages with respect to Laser Ablation-ICP Mass Spectrometry in many applications related to material analysis, biomedicine and environmental diagnostics. An application to the diagnostics of industrial ceramics is presented, demonstrating the feasibility of Double-Pulse LIBS Imaging and its advantages with respect to conventional single-pulse LIBS imaging.

  17. Dosimetry in Diagnostic Radiology for Paediatric Patients

    International Nuclear Information System (INIS)

    2013-01-01

    Concern about the radiation dose to children from diagnostic radiology examinations has recently been popularly expressed, particularly as related to computed tomography (CT) procedures. This involves the observation that children can receive doses far in excess of those delivered to adults, in part due to the digital nature of the image receptors that may give no warning to the operator of the dose to the patient. Concern for CT examinations should be extended to the broad range of paediatric diagnostic radiological procedures responsible for radiation doses in children, especially as factors, such as increased radiosensitivity and the longer life expectancy of children, increase the associated radiation risk. In all cases, owing to the added paediatric radiological examination factor of patient size and its associated impact on equipment selection, clinical examination protocol and dosimetric audit, the determination of paediatric dose requires a distinct approach from adult dosimetry associated with diagnostic radiological examinations. In response to this, there is a need to inform health professionals about standardized methodologies used to determine paediatric dose for all major modalities such as general radiography, fluoroscopy and CT. Methodologies for standardizing the conduct of dose audits and their use for the derivation and application of diagnostic reference levels for patient populations, that vary in size, are also required. In addition, a review is needed of the current knowledge on risks specific to non-adults from radiation, and also an analysis of the management of factors contributing to dose from paediatric radiological examinations. In 2007, the IAEA published a code of practice, Dosimetry in Diagnostic Radiology: An International Code of Practice, as Technical Reports Series No. 457 (TRS 457). TRS 457 recommends procedures for dosimetric measurement and calibration for the attainment of standardized dosimetry, and addresses requirements

  18. 42 CFR 415.180 - Teaching setting requirements for the interpretation of diagnostic radiology and other diagnostic...

    Science.gov (United States)

    2010-10-01

    ... interpretation of diagnostic radiology and other diagnostic tests. 415.180 Section 415.180 Public Health CENTERS... for the interpretation of diagnostic radiology and other diagnostic tests. (a) General rule. Physician fee schedule payment is made for the interpretation of diagnostic radiology and other diagnostic tests...

  19. Overview of recent results from the Tore Supra ECE diagnostics

    International Nuclear Information System (INIS)

    Talvard, M.; Liu, W.D.; Giruzzi, G.

    1993-01-01

    The Tore Supra ECE diagnostic system consists of a set of 3 Michelson and 12 Fabry-Perot interferometers, which is now fully operational. We present results obtained with the 3 Michelson during LHCD experiments first. It is shown how the sensitivity of the diagnostic to rather high v (perpendicular) prevents detection of v (parallel) anisotropies. On the other hand, measurements during the Ohmic phase reveal some unexpected anisotropy which can be attributed to superthermal electrons related to the bootstrap current. The 12 Fabry-Perot have been operated using high acquisition sampling rates during pellet injection experiments. A shudder preceding the pellet itself is clearly evidenced just before an internal disruption occurs. During sawtooth activity, such measurements are also used to study the dynamics of the m=1, n=1 instability on the q=1 surface itself

  20. Prevalence of Internalized Homophobia and HIV Associated Risks ...

    African Journals Online (AJOL)

    This study assessed the level of internalized homophobia and associated factors among men who have sex with men (MSM) in Nigeria. Using respondent driven sampling, MSM were recruited in Lagos and Ibadan between July and September, 2006. Internalized homophobia was assessed as a negative composite score ...

  1. The morphing properties of a vascular shape memory composite

    International Nuclear Information System (INIS)

    Cortes, P; Kubas, G; Terzak, J; Phillips, D; Baur, J W

    2014-01-01

    This work investigates the fabrication, experimentation, testing, and modeling of shape memory composites consisting of two-way shape memory alloy (SMA) tubes embedded in a shape memory polymer (SMP) matrix. The hybrid system here investigated is thermally activated via internal transport of thermal fluids through the SMA vascular system. The resulting shape memory composite (SMC) combines the high modulus and high specific actuation force of SMAs with the strong shape fixing and variable stiffness of SMPs to create a light-weight composite capable of controllably and rapidly achieving two shape memory states. Specifically, a 25° thermally induced out-of-plane bending state is achieved with a 2% volume fraction of SMA in the composite after 2 min of being activated by an internal thermal fluid. Here, while the thermal structural design of the SMC was not optimized and the thermal cycling was significantly restricted by the low thermal conduction of the SMP, the deflection of the composite was within 20% of the expected value modeled by the thermal–mechanical finite element analysis (FEA) here performed. The close agreement between the experimental performance and the modeled composite response suggests that morphing composites based on SMAs and SMPs are promising structures for adaptive applications. (paper)

  2. Dutch radiodiagnostics viewed internationally

    International Nuclear Information System (INIS)

    Valois, J.C. de

    1990-01-01

    Dutch radiodiagnostics viewed internationally. - A quantitative description of diagnostic radiology is given in terms of radiological density (the number of radiological examinations per 1000 inhibitants), consumptions of roentgen film and contrast media. The data concerning examinations were recorded by a yearly inquiry system addressing all Dutch radiologists. The consumption of film and contrast media were derived from the data banks of the industries. In comparing these data with the data for Western Europe, Japan and the United States it is remarkable that diagnostic radiology scores lowest in regard to density, film consumption and use of contrast media. Only in the use of 35 mm cinefilm (coronary angiography) is The Netherlands number 2 on the list preceded by the United States. As a consequence radiation exposure of the population caused by diagnostic radiology is low in The Netherlands. Although the technical condition of the equipment is good due to regular and preventive service the life-span of the radiological equipment is gradually increasing beyond the limits of the normal economic depreciation. Growing arrears are found in the application of new technology: ultrasound, computer tomography and magnetic resonance imaging. The substitution of high osmolar contrast media by low osmolar media is also laggin gbehind. (author). 10 refs.; 1 fig.; 4 tab

  3. Substance use disorders: Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10).

    Science.gov (United States)

    Hasin, Deborah; Hatzenbuehler, Mark L; Keyes, Katherine; Ogburn, Elizabeth

    2006-09-01

    Two major nomenclatures, Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV) and International Classification of Diseases, tenth edition (ICD-10), currently define substance use disorders for broad audiences of users with different training, experience and interests. A comparison of these definitions and their implications for DSM-V and ICD-11 has not been available. The background for the dependence concept and abuse, harmful use, withdrawal, substance-induced disorders and remission and other substance-related conditions is reviewed. Reliability evidence is presented, as is validity evidence from approaches including psychometric, genetic and animal studies. The relevance of the DSM-IV and ICD-10 compared to alternative systems (e.g. the Addiction Severity Index) is considered. Reliability and psychometric validity evidence for substance dependence is consistently strong, but more mixed for abuse and harmful use. Findings on the genetics of alcohol disorders support the validity of the dependence concept, while animal studies underscore the centrality of continued use despite negative consequences to the concept of dependence. While few studies on substance-induced disorders have been conducted, those published show good reliability and validity when elements of DSM-IV and ICD-10 are combined. Dependence in DSM-V and ICD-11 should be retained, standardizing both criteria sets and adding a severity measure. The consequences of heavy use should be measured independently of dependence; add cannabis withdrawal if further research supports existing evidence; conduct further studies of the substance-induced psychiatric categories; standardize their criteria across DSM-V and ICD-11; develop a theoretical basis for better remission criteria; consider changing substance 'abuse' to substance 'dysfunction disorder'; and conduct clinician education on the value of the diagnostic criteria.

  4. Bilateral internal laryngoceles mimicking asthma

    Directory of Open Access Journals (Sweden)

    Elif A Aksoy

    2013-01-01

    Full Text Available Laryngocele is an air-filled, abnormal dilation of the laryngeal saccule that extends upward within the false vocal fold, in communication with the laryngeal lumen. A case of 43-year-old male with bilateral internal laryngoceles, who has been treated as asthma for 4 years, is presented. The patient had dyspnea, cough, and excessive phlegm for a month and a late onset stridor. Flexible nasopharyngolaryngoscopy showed bilateral cystic enlargements of the false vocal folds and true vocal folds could not be visualized. Laryngeal CT without contrast enhancement showed bilateral internal laryngoceles. Submucosal total excision of bilateral cystic masses including parts of false vocal folds was performed. The symptoms resolved immediately after surgery. Although the incidence of internal laryngocele is rare, it should be remembered in the differential diagnosis of upper airway problems and diagnostic flexible nasopharnygolaryngoscopy is routinely indicated for airway evaluation in at-risk patients.

  5. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Additional information

    International Nuclear Information System (INIS)

    2009-03-01

    The reports from Argentina, Canada, India, Korea and Romania are presented concerning the projects carried out under the Coordinated Research Program (CRP) I3.30.10 of the International Agency for Atomic Energy - Vienna related to 'Intercomparison of Techniques for Pressure Tube Inspection and Diagnostics'

  6. Convergent and diagnostic validity of STAVUX, a word and pseudoword spelling test for adults.

    Science.gov (United States)

    Östberg, Per; Backlund, Charlotte; Lindström, Emma

    2016-10-01

    Few comprehensive spelling tests are available in Swedish, and none have been validated in adults with reading and writing disorders. The recently developed STAVUX test includes word and pseudoword spelling subtests with high internal consistency and adult norms stratified by education. This study evaluated the convergent and diagnostic validity of STAVUX in adults with dyslexia. Forty-six adults, 23 with dyslexia and 23 controls, took STAVUX together with a standard word-decoding test and a self-rated measure of spelling skills. STAVUX subtest scores showed moderate to strong correlations with word-decoding scores and predicted self-rated spelling skills. Word and pseudoword subtest scores both predicted dyslexia status. Receiver-operating characteristic (ROC) analysis showed excellent diagnostic discriminability. Sensitivity was 91% and specificity 96%. In conclusion, the results of this study support the convergent and diagnostic validity of STAVUX.

  7. Diagnostic value of DIAGNOdent in detecting caries under composite restorations of primary molars

    Directory of Open Access Journals (Sweden)

    Ava Vali Sichani

    2016-01-01

    Conclusion: DIAGNOdent showed a greater accuracy in detecting secondary caries under primary molar restorations, compared to radiographs. Although DIAGNOdent is an effective method for detecting caries under composite restorations, it is better to be used as an adjunctive method alongside other detecting procedures.

  8. Reactor internals vibration monitoring by neutron noise methods in PWRs

    International Nuclear Information System (INIS)

    Pazsit, I.; Por, G.; Lux, I.

    1983-01-01

    Certain elements of PWR cores such as control/fuel rods or cassettes, or other parts of reactor internals, often represent a vibration problem. Early analyses at operating PWR plant revealed that these vibrations can be detected by in-core neutron detectors, opening up the possibility of vibration monitoring and diagnostics by noise methods. Theoretical methods of calculating vibration induced neutron noise and its application to vibration diagnostics are summarized. Experiments to check theoretical conclusions are under way at the Central Research Institute for Physics, Budapest. (author)

  9. A new visible spectroscopy diagnostic for the JET ITER-like wall main chamber

    International Nuclear Information System (INIS)

    Maggi, C. F.; Brezinsek, S.; Stamp, M. F.; Griph, S.; Heesterman, P.; Hogben, C.; Horton, A.; Meigs, A.; Studholme, W.; Zastrow, K.-D.; Morlock, C.

    2012-01-01

    In preparation for ITER, JET has been upgraded with a new ITER-like wall (ILW), whereby the main plasma facing components, previously of carbon, have been replaced by mainly Be in the main chamber and W in the divertor. As part of the many diagnostic enhancements, a new, survey, visible spectroscopy diagnostic has been installed for the characterization of the ILW. An array of eight lines-of-sight (LOS) view radially one of the two JET neutral beam shine through areas (W coated carbon fibre composite tiles) at the inner wall. In addition, one vertical LOS views the solid W tile at the outer divertor. The light emitted from the plasma is coupled to a series of compact overview spectrometers, with overall wavelength range of 380–960 nm and to one high resolution Echelle overview spectrometer covering the wavelength range 365–720 nm. The new survey diagnostic has been absolutely calibrated in situ by means of a radiometric light source placed inside the JET vessel in front of the whole optical path and operated by remote handling. The diagnostic is operated in every JET discharge, routinely monitoring photon fluxes from intrinsic and extrinsic impurities (e.g., Be, C, W, N, and Ne), molecules (e.g., BeD, D 2 , ND) and main chamber and divertor recycling (typically Dα, Dβ, and Dγ). The paper presents a technical description of the diagnostic and first measurements during JET discharges.

  10. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  11. Diagnostic dilemma

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Dobrovolny, Robert; Nazarenko, Irina

    2011-01-01

    Fabry disease, an X-linked lysosomal storage disorder, results from the deficient activity of a-galactosidase A (a-Gal A). In affected males, the clinical diagnosis is confirmed by the markedly decreased a-Gal A activity. However, in female heterozygotes, the a-Gal A activity can range from low t...... on enzyme replacement therapy. Thus, gene dosage analyses can detect large deletions (>50bp) in suspect heterozygotes for X-linked and autosomal dominant diseases that are "sequencing cryptic," resolving molecular diagnostic dilemmas....... to normal due to random X-chromosomal inactivation, and diagnostic confirmation requires identification of the family's a-Gal A gene mutation. In a young female who had occasional acroparesthesias, corneal opacities, and 15 to 50% of the lower limit of normal leukocyte a-Gal A activity, a-Gal A sequencing...... in two expert laboratories did not identify a confirmatory mutation, presenting a diagnostic dilemma. A renal biopsy proved diagnostic and renewed efforts to detect an a-Gal A mutation. Subsequent gene dosage analyses identified a large a-Gal A deletion confirming her heterozygosity, and she was started...

  12. The FAO/IAEA External Quality Assurance Programme (EQAP) and movement towards a generic veterinary diagnostic testing laboratory accreditation scheme. Report of an FAO/IAEA consultants meeting

    International Nuclear Information System (INIS)

    2002-01-01

    establish a network of national veterinary diagnostic testing laboratories that are recognized for their achievements in establishing QA systems and their proficiency in the use of specific diagnostic assays. This network would facilitate the exchange of epidemiological information and, in the current atmosphere of international and regional trade agreements, provide a greater opportunity to increase the share of developing countries in the international trade of livestock and livestock products. In February 1998, a Consultants' Meeting was convened to consider the design, impact, and proposals for future implementation of the current FAO/IAEA EQAP for Animal Disease Diagnosis and make recommendations with regard to its central purposes and future direction. In addition, the Consultants considered the broader question of a generic QA 'accreditation' scheme for veterinary diagnostic testing laboratories that could be made available through international, regional, or national organizations as appropriate to the country of interest. This broader discussion was stimulated by the fact that few developed and no developing countries have nationally organized schemes to measure and recognize the QA systems and technical competence of veterinary diagnostic testing laboratories, but that such a scheme is of vital importance to the quality of policy decisions and actions taken on national animal health issues and the international trade of livestock and livestock commodities. It followed that, in the Subprogramme's role as a Collaborating Centre to the Office International Epizooties (OIE, or World Animal Health Organization), it would be appropriate to consider the FAO/IAEA EQAP within the broader scope of an international scheme for veterinary diagnostic laboratory accreditation for two reasons: 1) to use information learned through the design and implementation of the FAO/IAEA EQAP to assist in the appropriate development of an international scheme and 2) to ensure that the FAO

  13. Machining of Metal Matrix Composites

    CERN Document Server

    2012-01-01

    Machining of Metal Matrix Composites provides the fundamentals and recent advances in the study of machining of metal matrix composites (MMCs). Each chapter is written by an international expert in this important field of research. Machining of Metal Matrix Composites gives the reader information on machining of MMCs with a special emphasis on aluminium matrix composites. Chapter 1 provides the mechanics and modelling of chip formation for traditional machining processes. Chapter 2 is dedicated to surface integrity when machining MMCs. Chapter 3 describes the machinability aspects of MMCs. Chapter 4 contains information on traditional machining processes and Chapter 5 is dedicated to the grinding of MMCs. Chapter 6 describes the dry cutting of MMCs with SiC particulate reinforcement. Finally, Chapter 7 is dedicated to computational methods and optimization in the machining of MMCs. Machining of Metal Matrix Composites can serve as a useful reference for academics, manufacturing and materials researchers, manu...

  14. Application of the spectral-correlation method for diagnostics of cellulose paper

    Science.gov (United States)

    Kiesewetter, D.; Malyugin, V.; Reznik, A.; Yudin, A.; Zhuravleva, N.

    2017-11-01

    The spectral-correlation method was described for diagnostics of optically inhomogeneous biological objects and materials of natural origin. The interrelation between parameters of the studied objects and parameters of the cross correlation function of speckle patterns produced by scattering of coherent light at different wavelengths is shown for thickness, optical density and internal structure of the material. A detailed study was performed for cellulose electric insulating paper with different parameters.

  15. Diagnostic and Prognostic Impact of pc-ASPECTS Applied to Perfusion CT in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Pallesen, Lars-Peder; Gerber, Johannes; Dzialowski, Imanuel; van der Hoeven, Erik J R J; Michel, Patrik; Pfefferkorn, Thomas; Ozdoba, Christoph; Kappelle, L Jaap; Wiedemann, Baerbel; Khomenko, Andrei; Algra, Ale; Hill, Michael D; von Kummer, Ruediger; Demchuk, Andrew M; Schonewille, Wouter J; Puetz, Volker

    2015-01-01

    The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality. Copyright © 2014 by the American Society of Neuroimaging.

  16. Implementation of Rapid Molecular Infectious Disease Diagnostics: the Role of Diagnostic and Antimicrobial Stewardship.

    Science.gov (United States)

    Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R

    2017-03-01

    New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics. Copyright © 2017 American Society for Microbiology.

  17. Strength and thermal stability of Cu-Al2O3 composite obtained by internal oxidation

    Directory of Open Access Journals (Sweden)

    Jovanovic, M. T.

    2010-12-01

    Full Text Available The objective of the work is to study the effects of the high-energy milling on strengthening, thermal stability and electrical conductivity of Cu-Al2O3 composite. The prealloyed copper powders, atomized in inert gas and containing 3 wt. % Al, were milled up to 20 h in the planetary ball mill to oxidize in situ aluminium with oxygen from the air. Composite compacts were obtained by hot-pressing in an argon atmosphere at 800 °C for 3 h under the pressure of 35MPa. The microstructural characterization was performed by the optical microscope, scanning electron microscope (SEM, transmission electron microscope (TEM and X-ray diffraction analysis (XRD. The microhardness, electrical conductivity and density measurements were also carried out. The effect of internal oxidation and high-energy milling on strengthening of Cu-Al2O3 composite was significant, The increase of the microhardness of composite compacts (292 HV is almost threefold comparing to compacts processed from the as-received Cu-3 wt. % Al powder (102 HV. The grain size of Cu-Al2O3 compacts processed from 5 and 20 h-milled powders was 75 and 45 nm, respectively. The small increase in the grain size and the small microhardness drop indicate the high thermal stability of Cu-Al2O3 composite during high-temperature exposure at 800 °C.El objetivo del trabajo es el estudio de los efectos de la pulverización con altas energías sobre la resistencia, estabilidad térmica y conductividad eléctrica del compuesto Cu-Al2O3. El polvo pre-aleado de cobre, obtenido a través de la atomización con gas inerte y con un contenido de 3wt. % Al, se molió durante 20 h en el molino planetario de bolas dando lugar a la oxidación in situ del aluminio con el oxígeno del aire. El compuesto compactado se ha obtenido mediante prensado en caliente en atmósfera de argón a 800 °C durante 3 h y a una presión de 35MPa. La caracterización microestructural se hizo a través de microscopia óptica, microscopia

  18. [Diagnostic value of selective anorexia in pathological weight loss].

    Science.gov (United States)

    Braquet, P; Mercier, G; Reynes, J; Jeandel, C; Pinzani, V; Guilpain, P; Rivière, S; Le Quellec, A

    2016-02-01

    The diagnostic value of selective anorexia is debated. Some authors have suggested an association between meat aversion and cancer, but most do not use it as a diagnostic tool. We aimed to characterize anorexia of different diseases to search for an association between selective aversions and diagnostic groups. All the patients admitted to three departments of a teaching hospital were included consecutively for 22months if they had more than 10 % weight loss in less than one year. Patients were excluded if history taking was not reliable, or if they suffered from anorexia nervosa. We compiled diagnoses at discharge and validated them six months later. We used logistic regression to identify independent factors associated with selective anorexia. Inclusion criteria were met in 106patients (female 44 %, median age 65years). Most frequent diagnoses were: cancer (36 %), infection (35 %), digestive diseases (19 %), non organic diseases (21 %). Recent selective anorexia was found in 46 % of the cases. It was significantly associated with female gender (P=0.002), marginally with young age (P=0.069) and long duration of weight loss (P=0.079). Opioid use at admission was negatively associated with selective anorexia (P=0.001). No specific diagnostic category was found to be associated. Selective anorexia does not appear to be a useful symptom to investigate pathological weight loss. It behaves more like a non-specific reactivation by current disease of earlier latent personal food aversions. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  19. The motional stark effect with laser-induced fluorescence diagnostic

    Science.gov (United States)

    Foley, E. L.; Levinton, F. M.

    2010-05-01

    The motional Stark effect (MSE) diagnostic is the worldwide standard technique for internal magnetic field pitch angle measurements in magnetized plasmas. Traditionally, it is based on using polarimetry to measure the polarization direction of light emitted from a hydrogenic species in a neutral beam. As the beam passes through the magnetized plasma at a high velocity, in its rest frame it perceives a Lorentz electric field. This field causes the H-alpha emission to be split and polarized. A new technique under development adds laser-induced fluorescence (LIF) to a diagnostic neutral beam (DNB) for an MSE measurement that will enable radially resolved magnetic field magnitude as well as pitch angle measurements in even low-field (experiments. An MSE-LIF system will be installed on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. It will enable reconstructions of the plasma pressure, q-profile and current as well as, in conjunction with the existing MSE system, measurements of radial electric fields.

  20. Laser Induced Fluorescence Diagnostic for the Plasma Couette Experiment

    Science.gov (United States)

    Katz, Noam; Skiff, Fred; Collins, Cami; Weisberg, Dave; Wallace, John; Clark, Mike; Garot, Kristine; Forest, Cary

    2010-11-01

    The Plasma Couette Experiment (PCX) at U. Wisconsin-Madison consists of a rotating high-beta plasma and is well-suited to the study of flow-driven, astrophysically-relevant plasma phenomena. PCX confinement relies on alternating rings of 1kG permanent magnets and the rotation is driven by electrode rings, interspersed between the magnets, which provide an azimuthal ExB. I will discuss the development of a laser-induced fluorescence diagnostic (LIF) to characterize the ion distribution function of argon plasmas in PCX. The LIF system--which will be scanned radially--will be used to calibrate internal Mach probes, as well as to measure the time-resolved velocity profile, ion temperature and density non-perturbatively. These diagnostics will be applied to study the magneto-rotational instability in a plasma, as well as the buoyancy instability thought to be involved in producing the solar magnetic field. This work is supported by NSF and DOE.