WorldWideScience

Sample records for complex implant case

  1. [Complex skull defects reconstruction with САD/САМ titanium and polyetheretherketone (PEEK) implants].

    Science.gov (United States)

    Eolchiyan, S A

    2014-01-01

    Predictable and stable functional and aesthetic result is the aim of priority for the neurosurgeon dealing with the reconstruction of large cranial bone defects and complex-formed skull defects involving cranio-orbital region. the paper presents the experience with САD/САМ titanium and polyetheretherketone (PEEK) implants for complex-formed and large skull bone defects reconstruction. Between 2005 and 2013 nine patients (5 females and 4 males) underwent cranioplasty and cranio-facial reconstruction with insertion of the customized САD/САМ titanium and PEEK implants. Computer-assisted preoperative planning was undertaken by the surgeon and the engineer together in 3 cases to provide accurate implant design. Eight patients had complex-formed and large posttraumatic defects of fronto-orbital (7 cases) and parietal (one case) regions. In two of these cases one-step reconstruction surgery for posttraumatic fronto-orbital defects combined with adjacent orbital roof (one case) and orbito-zygomatic (one case) deformities was performed. One patient underwent one-step primary cranioplasty after cranio-orbital fibrous dysplasia focus resection. Titanium implants were used in 4 cases while PEEK implants - in 5 ones. The follow-up period ranged from 6 months till 8,5 years (median 4,4 years). The accuracy of the implant intraoperative fit was perfect in all cases. Postoperative wounds healed primary and there were no any complications in the series presented. Post-op clinical assessment and CT data testified to high implants precision, good functional and aesthetic outcomes in all patients. САD/САМ titanium and PEEK implants application should allow for optimal reconstruction in the challenging patients with complex-formed and large skull bone defects providing predictable good functional and aesthetic result together with surgery morbidity and duration reduction. Computer-assisted preoperative planning should be undertaken for САD/САМ implants creation in

  2. Dental implants in medically complex patients-a retrospective study.

    Science.gov (United States)

    Manor, Yifat; Simon, Roy; Haim, Doron; Garfunkel, Adi; Moses, Ofer

    2017-03-01

    Dental implant insertion for oral rehabilitation is a worldwide procedure for healthy and medically compromised patients. The impact of systemic disease risks on the outcome of implant therapy is unclear, since there are few if any published randomized controlled trials (RCTs). The objective of this study is to investigate the rate of complications and failures following dental implantation in medically compromised patients in order to elucidate risk factors and prevent them. A retrospective cohort study was conducted from patient files treated with dental implantation between the years 2008-2014. The study group consisted of medically complex patients while the control group consisted of healthy patients. Preoperative, intraoperative, and post operative clinical details were retrieved from patients' files. The survival rate and the success rate of the dental implants were evaluated clinically and radiographically. A total of 204 patients (1003 dental implants) were included in the research, in the study group, 93 patients with 528 dental implants and in the control group, 111 patients with 475 dental implants. No significant differences were found between the groups regarding implant failures or complications. The failure rate of dental implants among the patients was 11.8 % in the study group and 16.2 % in the control group (P = 0.04). It was found that patients with a higher number of implants (mean 6.8) had failures compared with patients with a lower number of implants (mean 4.2) regardless of their health status (P dental implantation in medically complex patients and in healthy patients. Medically complex patients can undergo dental implantation. There are similar rates of complications and failures of dental implants in medically complex patients and in healthy patients.

  3. Development of implant/interconnected porous hydroxyapatite complex as new concept graft material.

    Directory of Open Access Journals (Sweden)

    Kazuya Doi

    Full Text Available BACKGROUND: Dental implant has been successfully used to replace missing teeth. However, in some clinical situations, implant placement may be difficult because of a large bone defect. We designed novel complex biomaterial to simultaneously restore bone and place implant. This complex was incorporated implant into interconnected porous calcium hydroxyapatite (IP-CHA. We then tested this Implant/IP-CHA complex and evaluated its effect on subsequent bone regeneration and implant stability in vivo. METHODOLOGY/PRINCIPAL FINDINGS: A cylinder-type IP-CHA was used in this study. After forming inside of the cylinder, an implant was placed inside to fabricate the Implant/IP-CHA complex. This complex was then placed into the prepared bone socket in the femur of four beagle-Labrador hybrid dogs. As a control, implants were placed directly into the femur without any bone substrate. Bone sockets were allowed to heal for 2, 3 and 6 months and implant stability quotients (ISQ were measured. Finally, tissue blocks containing the Implant/IP-CHA complexes were harvested. Specimens were processed for histology and stained with toluidine blue and bone implant contact (BIC was measured. The ISQs of complex groups was 77.8±2.9 in the 6-month, 72.0±5.7 in the 3-month and 47.4±11.0 in the 2-month. There was no significant difference between the 3- or 6-month complex groups and implant control groups. In the 2-month group, connective tissue, including capillary angiogenesis, was predominant around the implants, although newly formed bone could also be observed. While, in the 3 and 6-month groups, newly formed bone could be seen in contact to most of the implant surface. The BICs of complex groups was 2.18±3.77 in the 2-month, 44.03±29.58 in the 3-month, and 51.23±8.25 in the 6-month. Significant difference was detected between the 2 and 6-month. CONCLUSIONS/SIGNIFICANCE: Within the results of this study, the IP-CHA/implant complex might be able to achieve both

  4. Management of dental implant fractures. A case history.

    Science.gov (United States)

    Al Quran, Firas A M; Rashan, Bashar A; Al-Dwairi, Ziad N

    2009-01-01

    The widespread use of endosseous osseointegrated implants to replace missing natural teeth increases the chances of implant complications and failures, despite the high initial success rate reported in the literature. Implant fracture is one possible complication that results in ultimate failure of the dental implant. Such a complication poses a management crisis even for the most experienced clinician. This article reports on a case of implant fracture, its possible causes, and how the case was managed.

  5. Implant-Retained Auricular Prosthesis: A Case Report

    OpenAIRE

    Ozturk, A. Nilgun; Usumez, Aslihan; Tosun, Zekeriya

    2010-01-01

    Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis. In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This...

  6. Analysis of 30 breast implant rupture cases.

    Science.gov (United States)

    Tark, Kwan Chul; Jeong, Hii Sun; Roh, Tae Suk; Choi, Jong Woo

    2005-01-01

    Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat

  7. Evolution of design considerations in complex craniofacial reconstruction using patient-specific implants.

    Science.gov (United States)

    Peel, Sean; Bhatia, Satyajeet; Eggbeer, Dominic; Morris, Daniel S; Hayhurst, Caroline

    2017-06-01

    Previously published evidence has established major clinical benefits from using computer-aided design, computer-aided manufacturing, and additive manufacturing to produce patient-specific devices. These include cutting guides, drilling guides, positioning guides, and implants. However, custom devices produced using these methods are still not in routine use, particularly by the UK National Health Service. Oft-cited reasons for this slow uptake include the following: a higher up-front cost than conventionally fabricated devices, material-choice uncertainty, and a lack of long-term follow-up due to their relatively recent introduction. This article identifies a further gap in current knowledge - that of design rules, or key specification considerations for complex computer-aided design/computer-aided manufacturing/additive manufacturing devices. This research begins to address the gap by combining a detailed review of the literature with first-hand experience of interdisciplinary collaboration on five craniofacial patient case studies. In each patient case, bony lesions in the orbito-temporal region were segmented, excised, and reconstructed in the virtual environment. Three cases translated these digital plans into theatre via polymer surgical guides. Four cases utilised additive manufacturing to fabricate titanium implants. One implant was machined from polyether ether ketone. From the literature, articles with relevant abstracts were analysed to extract design considerations. In all, 19 frequently recurring design considerations were extracted from previous publications. Nine new design considerations were extracted from the case studies - on the basis of subjective clinical evaluation. These were synthesised to produce a design considerations framework to assist clinicians with prescribing and design engineers with modelling. Promising avenues for further research are proposed.

  8. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  9. Straightforward Case of Dental Implant in General Dentistry

    Directory of Open Access Journals (Sweden)

    Aji P. Tjikman

    2013-07-01

    Full Text Available Dental implant has become a fast developing and dynamic field in dental practice. It is acknowledged as a predictable treatment modality with high clinical success rates. Conventional fixed prostheses are no longer considered to be the first choice of treatment for replacing a missing tooth. Despite the increasing number of patients requesting dental implant treatments, there are only some clinicians who are offering implant therapy in their daily practice. The International team for Implantology described a straightforward case as a simple case such as implant placements in adquate soft and hard tissue conditions and single-tooth restorations in a non-aesthetic zone. A review of the current literature discussed the implementation of implant dentistry in universities worldwide into their curriculum for both undergraduate and postgraduate programs in general dentistry. The European consensus in implant dentistry education concluded that it is desirable to include the surgical technique for implant placement for straightforward cases into the dental curriculum. The levels and limitations to which the various aspects of implant dentistry and related skills are taught to be determined by the academic community. This review aimed at promoting awareness amongst dental practitioners and institutions in Indonesia of the shifting treatment paradigm in the maangement of a missing tooth. Hence clinicians will be able to include implant dentistry in the treatment planning of their patients and also undertake a significant part in the execution of such treatments.

  10. PIP breast implant removal: a study of 828 cases.

    Science.gov (United States)

    Oulharj, S; Pauchot, J; Tropet, Y

    2014-03-01

    In March, 2010, the French Health Products Safety Agency suspended the sale of prefilled silicone breast implants manufactured by Poly Implants Prosthèse Prothese (PIP) because of a high failure rate and the use of an inappropriate silicone gel that did not comply with CE marking. These findings led to an international medical crisis. In France, 30,000 female patients had PIP implants. In our Department, 1150 PIP breast implants had been implanted in 630 patients since 2001. A retrospective study was conducted to define the rupture rate of these implants and the complications that arise. The women included in the study underwent implant removal from May 2010 to September 2012 for preventive or curative reasons. Data were collected from medical records that included: results of clinical examination, breast ultrasound before removal, rates of implant rupture, results of biopsy of periprosthetic capsule and pericapsule tissue and postoperative complications. A total of 828 PIP breast implants were removed in 455 patients. The rate of ruptured implants was 7.73% (64/828), corresponding to 11.6% of patients. A periprosthetic effusion was associated with rupture in 44% of cases. Breast ultrasound indicated a rupture for 87 implants; 32% were true positives and 3% were false negatives. Periprosthetic capsule biopsy demonstrated the presence of a foreign body, which seemed to be silicone, in 26% of cases and the presence of inflammation in 13% of cases. No siliconoma-type lesion was identified in the pericapsular tissue at biopsy. A total of 14 implants presented perspiration at removal. A statistically significant difference was found between the rates of rupture for texturised implants as compared to the smooth-surfaced implants. There were eight post-revisional-surgery complications (1%) and three cases of breast adenocarcinoma. The preventive explantation of PIP breast implants is justified given the high failure rate (7.73%) and given patients' exposure to silicone

  11. Experimental identification of nitrogen-vacancy complexes in nitrogen implanted silicon

    Science.gov (United States)

    Adam, Lahir Shaik; Law, Mark E.; Szpala, Stanislaw; Simpson, P. J.; Lawther, Derek; Dokumaci, Omer; Hegde, Suri

    2001-07-01

    Nitrogen implantation is commonly used in multigate oxide thickness processing for mixed signal complementary metal-oxide-semiconductor and System on a Chip technologies. Current experiments and diffusion models indicate that upon annealing, implanted nitrogen diffuses towards the surface. The mechanism proposed for nitrogen diffusion is the formation of nitrogen-vacancy complexes in silicon, as indicated by ab initio studies by J. S. Nelson, P. A. Schultz, and A. F. Wright [Appl. Phys. Lett. 73, 247 (1998)]. However, to date, there does not exist any experimental evidence of nitrogen-vacancy formation in silicon. This letter provides experimental evidence through positron annihilation spectroscopy that nitrogen-vacancy complexes indeed form in nitrogen implanted silicon, and compares the experimental results to the ab initio studies, providing qualitative support for the same.

  12. The effects of familiarity and complexity on appraisal of complex songs by cochlear implant recipients and normal hearing adults.

    Science.gov (United States)

    Gfeller, Kate; Christ, Aaron; Knutson, John; Witt, Shelley; Mehr, Maureen

    2003-01-01

    The purposes of this study were (a) to develop a test of complex song appraisal that would be suitable for use with adults who use a cochlear implant (assistive hearing device) and (b) to compare the appraisal ratings (liking) of complex songs by adults who use cochlear implants (n = 66) with a comparison group of adults with normal hearing (n = 36). The article describes the development of a computerized test for appraisal, with emphasis on its theoretical basis and the process for item selection of naturalistic stimuli. The appraisal test was administered to the 2 groups to determine the effects of prior song familiarity and subjective complexity on complex song appraisal. Comparison of the 2 groups indicates that the implant users rate 2 of 3 musical genres (country western, pop) as significantly more complex than do normal hearing adults, and give significantly less positive ratings to classical music than do normal hearing adults. Appraisal responses of implant recipients were examined in relation to hearing history, age, performance on speech perception and cognitive tests, and musical background.

  13. COMPLEX OPTICAL CHARACTERIZATION OF MESH IMPLANTS AND ENCAPSULATION AREA

    Directory of Open Access Journals (Sweden)

    VALERIY P. ZAKHAROV

    2013-04-01

    Full Text Available Complex investigation of mesh implants was performed involving laser confocal microscopy, backscattered probing and OCT imaging methods. The growth of endomysium and fat tissue with microcirculation vessels was observed in the mesh encapsulation region. Confocal microscopy analysis shows that such pathologies complications such as necrosis formation and microcavities were localized in the area near implant fibers with the size compatible with fiber diameter. And the number of such formations increase with the increase of the size, number and density of microdefects on the implant surface. Results of numerical simulations show that it is possible to control implant installation up to the depth to 4 mm with a help of backscattering probing. The applicability of OCT imaging for mesh implant control was demonstrated. Special two-stage OCT image noise-reduction algorithm, including empirical mode decomposition, was proposed for contrast increase and better abnormalities visualization by halving the signal-to-noise ratio. Joint usage of backscattered probing and OCT allows to accurately ascertain implant and surrounding tissue conditions, which reduces the risk of relapse probability.

  14. Microbial Characteristics of Peri-Implantitis : A Case-Control Study

    NARCIS (Netherlands)

    de Waal, Y C M; Eijsbouts, H V L C; Winkel, E G; van Winkelhoff, A J

    BACKGROUND: Aim of this case-control study was to compare oral microbiological characteristics of subjects with healthy peri-implant conditions and subjects with peri-implantitis and to explore the influence of various patient-related and implant-related factors on the microbiological

  15. Rehabilitación sobre implantes oseointegrados A case with rehabilitation on boneintegrated implants

    Directory of Open Access Journals (Sweden)

    Leticia María Lemus Cruz

    2009-03-01

    Full Text Available Se presenta un caso de un paciente rehabilitado en la consulta de Implantología de la Facultad de Estomatología de Ciudad de La Habana. La historia de la implantología moderna se remonta a principios de los años 60, cuando Per-Ingvar Branemark sienta las bases de la osteointegración y describe los primeros implantes de titanio con forma de tornillo. Aunque antigua, es la prótesis más moderna. Si la meticulosidad es obligada en la elaboración de todo tipo de prótesis, en los trabajos de implantes no se admite el más mínimo fallo, desde la planificación del caso hasta la implantación de la prótesis en boca. Para obtener buenos resultados, las técnicas y los procesos han de observarse escrupulosamente. En nuestra Facultad se ha creado el Grupo de Implantología, que es el encargado de la colocación de implantes y la rehabilitación prótesica de estos. Para ello han sido utilizado diferentes tipos de implantes comercializados y patentizados al nivel mundial. Se reafirma que la rehabilitación sobre implantes mejora la calidad estética y funcional de los pacientes.A case of rehabilitation patient is presented seen in Implantation Science consulting room of Stomatology Faculty of Havana City. History of implantation science dates back to at the beginning of 60s, when Per-Ingvar Branemark creates the bases of bone-integration and to describe the firsts titanium implants in a screw form. Although ancient, it is the more modern prosthesis. If meticulousness if mandatory in elaboration of all type of prosthesis, in implants works it inadmissible the minimum of failure, from the case planning until prosthesis implantation in mouth. To achieve good results, techniques and processes has to be scrupulously observed. In our Faculty it has been created a group of Implantation Science, which is in charge of implants placement, and of the prosthetic rehabilitation of these. Thus, we used different types of marketed and showed at world level. It

  16. Preload, Coefficient of Friction, and Thread Friction in an Implant-Abutment-Screw Complex.

    Science.gov (United States)

    Wentaschek, Stefan; Tomalla, Sven; Schmidtmann, Irene; Lehmann, Karl Martin

    To examine the screw preload, coefficient of friction (COF), and tightening torque needed to overcome the thread friction of an implant-abutment-screw complex. In a customized load frame, 25 new implant-abutment-screw complexes including uncoated titanium alloy screws were torqued and untorqued 10 times each, applying 25 Ncm. Mean preload values decreased significantly from 209.8 N to 129.5 N according to the number of repetitions. The overall COF increased correspondingly. There was no comparable trend for the thread friction component. These results suggest that the application of a used implant-abutment-screw complex may be unfavorable for obtaining optimal screw preload.

  17. Qualitative case studies of five cochlear implant recipients' experience with music.

    Science.gov (United States)

    Bartel, Lee R; Greenberg, Simon; Friesen, Lendra M; Ostroff, Jodi; Bodmer, Daniel; Shipp, David; Chen, Joseph M

    2011-02-01

    Cochlear implantation has revolutionized the management of those who suffer from severe-to-profound hearing loss because many patients now achieve excellent speech understanding with objective testing. Nevertheless, speech understanding in noisy conditions and music appreciation remain significant challenges to cochlear implant (CI) users. Music appreciation is an extremely complex experience that is difficult to quantify through a conventional outcome study. This paper aims at documenting the experience of five CI patients with regard to music appreciation using qualitative techniques. This information was obtained through a semi-structured interview process. The interviews were then transcribed and analysed using a constant comparative method of qualitative description. The results together with medical case records were used to identify emerging themes. The common themes that evolved were: musical background, the experience of receiving the implant, current experience with music, attention, musical prediction ability, internal hearing, hedonic vs. critical listening, determination, and timbre perception. By documenting their experiences in this manner, novel insights into the patient perspective are provided that are unique to the literature. These descriptions will aid clinicians and researchers who work in the area of cochlear implantation to better understand the needs of their patients.

  18. Clinical and microbiological characteristics of peri-implantitis cases: a retrospective multicentre study.

    Science.gov (United States)

    Charalampakis, G; Leonhardt, Å; Rabe, P; Dahlén, G

    2012-09-01

    The aim of this study was to follow patient cases retrospectively in a longitudinal manner from the time of implant placement to the time they were diagnosed with peri-implant disease, and to identify associated clinical and microbiological features of peri-implant disease. A total of 281 patient cases were chosen from the archives of the Oral Microbiological Diagnostic Laboratory, Gothenburg, Sweden, based on bacterial samples taken from diseased implants. A form was designed and filled in separately for each case including data on patient, implant and disease profile. Most cases were severe peri-implantitis cases (91.4%). In 41.3% of the patients, peri-implantitis was developed early, already after having implants in function less than 4 years. The type of implant surface was significantly associated with the time in years implants were in function, before disease was developed (P < 0.05). The microbiological results by both culture and checkerboard analysis, although failed to fully correspond to the severity of the disease in terms of magnitude, proved to show that peri-implantitis is a polymicrobial anaerobic infection with increased number of AGNB (aerobic Gram-negative bacilli) in 18.6% of the patients. Peri-implantitis is a biological complication of implants in function that poses a threat to their long-term survival. It may develop earlier around implants with rough surfaces and it may represent a true infection. Microbiological sampling methods should be improved and uniformed so as to fully unveil the microbiological profile of the disease. © 2011 John Wiley & Sons A/S.

  19. Early bone anchorage to micro- and nano-topographically complex implant surfaces in hyperglycemia.

    Science.gov (United States)

    Ajami, Elnaz; Bell, Spencer; Liddell, Robert S; Davies, John E

    2016-07-15

    The aim of this work was to investigate the effect of implant surface design on early bone anchorage in the presence of hyperglycemia. 108 Wistar rats were separated into euglycemic (EG) controls and STZ-treated hyperglycemic (HG) groups, and received bilateral femoral custom rectangular implants of two surface topographies: grit blasted (GB) and grit-blast with a superimposed calcium phosphate nanotopography (GB-DCD). The peri-implant bone was subjected to a tensile disruption test 5, 7, and 9days post-operatively (n=28/time point); the force was measured; and the residual peri-implant bone was observed by scanning electron microscopy (SEM). Disruption forces at 5days were not significantly different from zero for the GB implants (p=0.24) in either metabolic group; but were for GB+DCD implants in both metabolic groups (pmicro-surfaced implants showed significantly different disruption forces at all time points (e.g. >15N and implants, as all values were very low (implant bone showed compromised intra-fibrillar collagen mineralization in hyperglycemia, while inter-fibrillar and cement line mineralization remained unaffected. Enhanced bone anchorage to the implant surfaces was observed on the nanotopographically complex surface independent of metabolic group. The compromised intra-fibrillar mineralization observed provides a mechanism by which early bone mineralization is affected in hyperglycemia. It is generally accepted that the hyperglycemia associated with diabetes mellitus compromises bone quality, although the mechanism by which this occurs is unknown. Uncontrolled hyperglycemia is therefore a contra-indication for bone implant placement. It is also known that nano-topographically complex implant surfaces accelerate early peri-implant healing. In this report we show that, in our experimental model, nano-topographically complex surfaces can mitigate the compromised bone healing seen in hyperglycemia. Importantly, we also provide a mechanistic explanation for

  20. Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

    Directory of Open Access Journals (Sweden)

    Yazdan Ghandi

    2016-10-01

    Conclusion: This case report was conducted on a newborn with CCHB associated with pulmonary disorder. The newborn was intubated due to respiratory distress and did not need pacemaker implantation; however, after 8-month follow up, excellent outcomes were observed. It seems that atelectasis and mechanical ventilation can intolerance, and pacemaker implantation did not need in NLE with CCHB with narrowing QRS complex.

  1. A case of peri-implantitis and osteoradionecrosis arising around dental implants placed before radiation therapy

    OpenAIRE

    Teramoto, Yuji; Kurita, Hiroshi; Kamata, Takahiro; Aizawa, Hitoshi; Yoshimura, Nobuhiko; Nishimaki, Humihiro; Takamizawa, Kazunobu

    2016-01-01

    A little is known about the effect of radiotherapy on the dental implants that have previously been osseointegrated and charged. Here, we reported a case of osteoradionecrosis which arose around dental implants placed before radiation therapy.

  2. Continuous Thoracic Sympathetic Ganglion Block in Complex Regional Pain Syndrome Patients with Spinal Cord Stimulation Implantation

    Directory of Open Access Journals (Sweden)

    EungDon Kim

    2016-01-01

    Full Text Available The sympathetic block is widely used for treating neuropathic pain such as complex regional pain syndrome (CRPS. However, single sympathetic block often provides only short-term effect. Moreover, frequent procedures for sympathetic block may increase the risk of complications. The use of epidural route may be limited by concern of infection in case of previous implantation of the spinal cord stimulation (SCS. In contrast, a continuous sympathetic block can be administered without such concerns. The continuous thoracic sympathetic block (TSGB has been used to treat the ischemic disease and other neuropathic conditions such as postherpetic neuralgia. We administered continuous thoracic sympathetic block using catheter in CRPS patients who underwent SCS implantations and achieved desirable outcomes. We believe a continuous sympathetic block is a considerable option before performing neurolysis or radiofrequency rhizotomy and even after SCS implantation.

  3. Sapphire implant based neuro-complex for deep-lying brain tumors phototheranostics

    Science.gov (United States)

    Sharova, A. S.; Maklygina, YU S.; Yusubalieva, G. M.; Shikunova, I. A.; Kurlov, V. N.; Loschenov, V. B.

    2018-01-01

    The neuro-complex as a combination of sapphire implant optical port and osteoplastic biomaterial "Collapan" as an Aluminum phthalocyanine nanoform photosensitizer (PS) depot was developed within the framework of this study. The main goals of such neuro-complex are to provide direct access of laser radiation to the brain tissue depth and to transfer PS directly to the pathological tissue location that will allow multiple optical phototheranostics of the deep-lying tumor region without repeated surgical intervention. The developed complex spectral-optical properties research was carried out by photodiagnostics method using the model sample: a brain tissue phantom. The optical transparency of sapphire implant allows obtaining a fluorescent signal with high accuracy, comparable to direct measurement "in contact" with the tissue.

  4. Vacancy-acceptor complexes in germanium produced by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Feuser, U.; Vianden, R. (Inst. fuer Strahlen- und Kernphysik, Univ. Bonn (Germany)); Alves, E.; Silva, M.F. da (Dept. de Fisica, ICEN/LNETI, Sacavem (Portugal)); Szilagyi, E.; Paszti, F. (Central Research Inst. for Physics, Hungarian Academy of Sciences, Budapest (Hungary)); Soares, J.C. (Centro de Fisica Nuclear, Univ. Lisbon (Portugal))

    1991-07-01

    Combining results obtained by the {gamma}-{gamma} perturbed angular correlation method, Rutherford backscattering and elastic recoil detection of hydrogen, a defect complex formed in germanium by indium implantation is identified as a vacancy trapped by the indium probe. (orig.).

  5. Breast implant capsule-associated squamous cell carcinoma: a report of 2 cases.

    Science.gov (United States)

    Olsen, Daniel L; Keeney, Gary L; Chen, Beiyun; Visscher, Daniel W; Carter, Jodi M

    2017-09-01

    The use of prosthetic implants for breast augmentation has become commonplace. Although implants do not increase the risk of conventional mammary carcinoma, they are rarely associated with anaplastic large cell lymphoma. We report 2 cases of breast implant capsule-associated squamous cell carcinoma with poor clinical outcomes. Both patients (56-year-old woman and 81-year-old woman) had long-standing implants (>25 years) and presented with acute unilateral breast enlargement. In both cases, squamous cell carcinoma arose in (focally dysplastic) squamous epithelium-lined breast implant capsules and widely invaded surrounding breast parenchyma or chest wall. Neither patient had evidence of a primary mammary carcinoma or squamous cell carcinoma at any other anatomic site. Within 1 year, one patient developed extensive, treatment-refractory, locoregional soft tissue metastasis, and the second patient developed hepatic and soft tissue metastases and died of disease. There are 2 prior reported cases of implant-associated squamous cell carcinoma in the plastic surgery literature; one provides no pathologic staging or outcome information, and the second case was a capsule-confined squamous cell carcinoma. Together, all 4 cases share notable commonalities: the patients had long-standing breast implants and presented with acute unilateral breast pain and enlargement secondary to tumors arising on the posterior aspect of squamous epithelialized implant capsules. Because of both its rarity and its unusual clinical presentation, implant capsule-associated squamous cell carcinoma may be underrecognized. The aggressive behavior of the tumors in this series underscores the importance of excluding malignancy in patients with long-standing breast implants who present with acute unilateral breast pain and enlargement. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Intracranial Stent Implantation for Drug Resistant Atherosclerotic Stenosis: Results of 52 Cases

    International Nuclear Information System (INIS)

    Kim, Kuk Seon; Hwang, Dae Hyun; Ko, Young Hwan; Kang, Ik Won; Lee, Eil Seong; Han, You Mie; Kim, In Soo; Hur, Choon Woong

    2011-01-01

    We evaluated the usefulness of intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses. Between March 2004 and July 2007, we tried intracranial stent implantation in 49 patients with 52 lesions (anterior circulation 48 cases, posterior circulation 4 cases) who had an ischemic stroke with more than 50% of major cerebral artery stenosis. We classified the lesions by their location and morphology, analyzed the results in terms of the success rate, complication rate, and restenosis rate during the follow-up period. Intracranial stent implantation was performed successfully in 43 cases (82.7%). In eight of the nine cases, the stent implantation failure was due to the tortuosity of the target vessel. There was no major periprocedural complication. One patient showed cerebellar infarction after the procedure. Mean residual stenoses decreased from 70.2% to 13.0%. Four cases (9.3%) demonstrated in-stent restenoses and more than 50% during the mean and 25.3/month after the follow-up period. Success rate of intracranial stent implantation may improve on developing technique and more experience. Low rate of complication and restenosis suggest that we can consider intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses.

  7. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    Science.gov (United States)

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  8. A Case of Cochlear Implantation in Bromate-Induced Bilateral Sudden Deafness.

    Science.gov (United States)

    Eom, Tae-Ho; Lee, Sungsu; Cho, Hyong-Ho; Cho, Yong-Beom

    2015-04-01

    Despite the well-established nature of bromate-induced ototoxicity, cochlear implantation after bromate intoxication has been rarely documented. We hereby present a case of a 51-year-old female deafened completely after bromate ingestion. Her hearing was not restored by systemic steroid treatment and hearing aids were of no use. A cochlear implantation was performed on her right ear 3 months after the bromate ingestion. In bromate intoxication cases, early monitoring of hearing level is necessary and other drugs with potential ototoxicity should be avoided. The outcome of cochlear implantation was excellent in this case of bromate-induced deafness.

  9. Placement of implant bridge anterior maxilla post autograft (Serial case

    Directory of Open Access Journals (Sweden)

    Rifaat Nurrahma

    2016-06-01

    Full Text Available An advanced technology with implants based has now been developed in recent years.Implant with the bridge superstructure method is employed after variety of considerations where it is expected to meet its function, aesthetics, and comfortability.The alveolar bone existed is one reason for the process of adding bone (bonegraft.This case report proposes to determine the successful insertion of a superstructure anterior implant bridge post autograft.Two female patients were asked to use dental implant anterior with bridge system.The first case, the autograft application is made for a 20-year-old woman with edentulous teeth 11, 21, 22. One year later it was then inserted in the area of dental implant fixture 11 and 22. After 9 months, the healing abutments and the superstructure were inserted too.2 weeks after, the abutments of bridge and crowns of teeth 11, 21 and 22 with a pontic in the teeth 21 had been inserted. The second case, a 46-year-old woman with edentulous 11,12,21,22.They want to change the denture because they did not feel comfortable with the removable denture acrylic.Fixture placement was done a year after autograft.Insertion of healing abutments and the superstructure printing can be done after 6 months.A month later implant abutments and crowns could be inserted.Labial fullness is corrected; an implant-retained in the region of 12 and 21, 12, and 22 used the pontic.Prosthodontic rehabilitation with a fixed denture using the implant bridge after autograft anterior maxilla is an alternative fixed denture placement with satisfactory results, aesthetic correction and comfortably.

  10. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  11. A trabecular metal implant 4 months after placement: clinical-histologic case report.

    Science.gov (United States)

    Spinato, Sergio; Zaffe, Davide; Felice, Pietro; Checchi, Luigi; Wang, Hom-Lay

    2014-02-01

    The aim of this case report was to histologically evaluate the behavior of a trabecular metal (TM) implant composed of titanium and spatial 3-dimensional tantalum (Ta) trabeculae. This study is the first human histologic case report of this implant. A TM implant was placed in a 54-year-old woman exhibiting moderate chronic periodontitis. After periodontal treatment, the implant was inserted under favorable clinical conditions. Patient was not seen for 4 months because of unrelated breast reduction surgery. At the surgical reopening, periimplant inflammation affecting the coronal third of the implant was observed 4 months after implant placement. With patient's consent, the implant was removed for histologic analysis. Histology highlighted a greater amount of bone in close contact with Ta trabeculae than titanium surfaces. The finding of bone formation around the Ta trabeculae suggests that trabecular metal material promotes bone ingrowth for secondary implant stability. Additional evidence is needed to confirm this observation.

  12. Implant support for removable partial overdentures: a case report.

    Science.gov (United States)

    Halterman, S M; Rivers, J A; Keith, J D; Nelson, D R

    1999-01-01

    Functional stability and the preservation of remaining alveolar bone are primary, and often elusive, goals when restoring the partially edentulous arch. The incorporation of dental implants for the partial support of removable prostheses offers a practical adjunct in the fulfillment of these objectives. Planning for complex courses of treatment that include dental implants requires close coordination between the surgeon and the restorative dentist. Decisions that deal with type, location, size, number of implant fixtures, and design of the prosthesis are critical. All of these areas must be discussed and established as acceptable to the patient and each clinician before the initiation of treatment. In this report, we present a course of patient treatment in which a removable partial denture is supported by natural remaining teeth in conjunction with osseointegrated implants.

  13. Contemporary guided bone regeneration therapy for unaesthetic anterior peri-implantitis case

    Directory of Open Access Journals (Sweden)

    Benso Sulijaya

    2016-12-01

    Full Text Available Background: Dental implant is one of an alternative solutions reconstruction therapy for missing teeth. Complication of dental implant could occurs and leading to implant failure. In order to restore the complication, surgical treatment with guided bone regeneration (GBR is indicated. The potential use of bone substitutes is widely known to be able to regenerate the bone surrounding the implant and maintain bone volume. Purpose: The study aimed to demonstrate the effectiveness of implant-bone fully coverage by using sandwich technique of biphasic calcium phosphate (BCP and demineralized freeze-dried bone allografts (DFDBA bone substitutes combined with collagen resorbable membrane. Case: A 24-year-old male came with diagnosis of peri-implantitis on implant #11. Clinical finding indicated that implant thread was exposed on the labial aspect. Case management: After initial therapy including oral hygiene improvement performed, an operator did a contemporary GBR to correct the defect. Bone graft materials used were 40% β-tri calcium phosphate (β-TCP-60% hydroxyapatite (HA on the outer layer and DFDBA on the inner layer of the defect. Resorbable collagen membrane was used to cover the graft. Conclusion: GBR with sandwich technique could serve as one of the treatment choices for correcting an exposed anterior implant that would enhance the successful aesthetic outcome.

  14. Low-Cost 3D Printing Orbital Implant Templates in Secondary Orbital Reconstructions.

    Science.gov (United States)

    Callahan, Alison B; Campbell, Ashley A; Petris, Carisa; Kazim, Michael

    Despite its increasing use in craniofacial reconstructions, three-dimensional (3D) printing of customized orbital implants has not been widely adopted. Limitations include the cost of 3D printers able to print in a biocompatible material suitable for implantation in the orbit and the breadth of available implant materials. The authors report the technique of low-cost 3D printing of orbital implant templates used in complex, often secondary, orbital reconstructions. A retrospective case series of 5 orbital reconstructions utilizing a technique of 3D printed orbital implant templates is presented. Each patient's Digital Imaging and Communications in Medicine data were uploaded and processed to create 3D renderings upon which a customized implant was designed and sent electronically to printers open for student use at our affiliated institutions. The mock implants were sterilized and used intraoperatively as a stencil and mold. The final implant material was chosen by the surgeons based on the requirements of the case. Five orbital reconstructions were performed with this technique: 3 tumor reconstructions and 2 orbital fractures. Four of the 5 cases were secondary reconstructions. Molded Medpor Titan (Stryker, Kalamazoo, MI) implants were used in 4 cases and titanium mesh in 1 case. The stenciled and molded implants were adjusted no more than 2 times before anchored in place (mean 1). No case underwent further revision. The technique and cases presented demonstrate 1) the feasibility and accessibility of low-cost, independent use of 3D printing technology to fashion patient-specific implants in orbital reconstructions, 2) the ability to apply this technology to the surgeon's preference of any routinely implantable material, and 3) the utility of this technique in complex, secondary reconstructions.

  15. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    Science.gov (United States)

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  16. Telescopic crowns as attachments for implant supported restorations: a case series.

    Science.gov (United States)

    Hoffmann, Oliver; Beaumont, Christian; Tatakis, Dimitris N; Zafiropoulos, Gregory-George

    2006-01-01

    The use of dental implants to support mandibular or maxillary overdentures is a widely used treatment modality. Advantages are an increase in retention, an increase in chewing ability, and easy access for oral hygiene procedures. While telescopic and conical crowns have been used for decades to connect natural teeth to overdentures, not many cases have been reported in the literature of telescopic crowns placed on implants to support overdentures. This article describes 7 patients with overdentures supported by telescopic crowns who received 65 implants (ITI Straumann). The cases presented in this report have been in function for up to 4.5 years. During that time no adverse events were reported. The use of telescopic crowns as attachments for implant-supported overdentures may be a viable treatment option.

  17. COMPLEX TREATMENT IN A PATIENT WITH SEVERE CHRONIC PERIODONTITIS (Case Report.

    Directory of Open Access Journals (Sweden)

    Kamen Kotsilkov

    2015-02-01

    Full Text Available INTRODUCTION: Periodontitis is characterized by progressive destruction of periodontium, caused by relatively small group of microorganisms. The treatment aims to create proper environment which hampers the colonization of pathogens. The mechanical cleaning of the root surfaces combined with meticulous oral hygiene is the consensus treatment. In advanced cases the progression of the disease could lead to different problems - gingival recessions, insufficiency of attached gingiva, mobility and tooth loss which require complex treatment. OBJECTIVE: This presentation demonstrates the multidisciplinary treatment approach in a patient with a severe chronic periodontitis. METHODS: S.S. (42 with severe chronic periodontitis, insufficient mandibular vestibule depth, lack of keratinized gingiva, class III recessions and central incisors with grade III mobility. The #12 is missing and a crossbite is present on #32. The anti-infective therapy led to stable periodontal status. The corrective phase included the creation of vestibule depth with an autogenous gingival graft, dental implant placement with immediate provisional loading for #12, extraction of #31 and #41 due to attachment loss to the apex and immediate placement of provisionals with crossbite correction. RESULT: The reevaluation demonstrated good control of the gingival inflammation and stable periodontal status. The subsequent implant and prosthetic treatment led to the restoration of a functional dentition. CONCLUSION: The long term success of the treatment of the complex cases with severe chronic periodontitis depends significantly upon the proper control of the periodontal infection and the achievement of a stable periodontal status. These are the major prerequisites for successful further implant and prosthetic rehabilitation.

  18. Mandibular Two Mini Implants Overdenture Using Magnetic Attachments: A Case Report

    Directory of Open Access Journals (Sweden)

    Anna Miyayasu

    2017-12-01

    Full Text Available Many patients with an edentulous mandible struggle to use complete dentures. The instability of such dentures caused by the lack of retention, often causes discomfort, as well as functional and psychosocial problems, which can be signifcantly improved using implant overdentures with retentive attachments. This case report describes a successful case of a mandibular implant overdenture using two mini implants and magnetic attachments for an elderly edentulous patient. Case Report: A 62-year-old female with a thin mandibular bone ridge presented with complaints of pain caused by an unstable and unretentive complete mandibular denture. This patient received two mini implants (diameter: 2.6 mm; length: 12 mm with magnetic attachments. After three months, magnetic assemblies with magnetic attraction of 400 gf were incorporated into the intaglio surface of her mandibular overdenture. At 11 months, magnetic attraction was changed from 400 gf to 600 gf to provide a stronger magnetic force for improving the retention of this denture. Conclusion: Based on a two-year follow-up period, the mandibular two mini implants overdenture with magnetic attachments was successful in improving the patient’s general satisfaction with her dentures

  19. Advanced Implant-Prosthetic Rehabilitation: How to Obtain a Correct Restoration of Both Functions and Aesthetics in Patients with Complex Combined Dental and Maxillofacial Trauma: A Case Report and Topical Review of the Literature.

    Science.gov (United States)

    Figliuzzi, M M; Giudice, A; Fortunato, L

    2017-01-01

    Aim . This study aims to explain the main steps that characterize the implant-prosthetic rehabilitation in complex combined dental and maxillofacial trauma. Material and Methods . A 20-year-old patient reported an extensive facial trauma which also involved the alveolar process of the maxillary bone. The patient reported a maxillofacial fracture and the loss of teeth 1.3, 1.2, 1.1, and 2.1. A "Le Fort" type 2 fracture was also reported, with the malar bone involvement. After reduction and containment of bone fractures, through appropriate mounting plates, appropriate functional and aesthetic rehabilitation of the patient were replaced thanks to a temporary removable prosthesis. After 6 months, the patient performed numerous clinical investigations, aimed at a proper planning of implant-prosthetic rehabilitation of the upper dental arch. Conclusion . With the planning of the case, as well as respecting the surrounding biological structures, the surgery of implants can be carried out with the most appropriate procedure. Lastly, new dental implants with highly bioactive surfaces have been developed, providing an excellent and rapid bone integration.

  20. Mini-Implants: New Possibilities in Interdisciplinary Treatment Approaches

    Directory of Open Access Journals (Sweden)

    Biju Sebastian

    2014-01-01

    Full Text Available The introduction of mini-implants has broadened the range of tooth movements possible by fixed appliance therapy alone. The limits of fixed orthodontic treatment have become more a matter of facial appearance than anchorage. Many complex cases which would previously have required surgery or functional appliances can now be treated with fixed appliance therapy using mini-implants. A mutilated dentition case where mini-implants were used to provide anchorage for intrusion of molars and retraction of anterior teeth is reported here to illustrate this point.

  1. Use of mini dental implants in ectodermal dysplasia children: follow-up of three cases.

    Science.gov (United States)

    Sfeir, E; Nassif, N; Moukarzel, C

    2014-07-01

    Ectodermal dysplasia is a hereditary genodermatosis characterised by a congenital defect of ectodermal structures, causing tooth malformations and anomalies. Implantology has become accepted in these subjects. However cases are often complicated by a reduction in the size of the alveolar process, making the insertion of conventional implants difficult without bone grafting. The reduced diameter of mini-implants and their ease of insertion provide an interesting solution in supporting removable or fixed prosthesis. The purpose of this paper is to report the follow-up of three cases of children (11-12 year- old) with ectodermal dysplasia in which mini-implants were used to support the prostheses. In the first case, two mini-implants were inserted into the anterior part of the mandible for stabilising a removable denture (2 years follow-up). In the other two cases, mini- implants were inserted in the maxilla and mandible to replace missing front teeth with fixed prostheses. Patients were called for follow- up every 6 months: in the sencod case follow-up lasted 4 years in the mandible and 2 years in the maxilla; in the third case, 2 years in the maxilla and 1 year in the mandible. The use of mini-implants in children with ectodermal dysplasia can enhance aesthetics, and functional and psychosocial development.

  2. The Effect of Pro-Qura Case Volume on Post-Implant Prostate Dosimetry

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Lief, Jonathan H.; Grimm, Peter; Sylvester, John; Butler, Wayne M.; Allen, Zachariah A.

    2011-01-01

    Purpose: To evaluate the effect of prostate brachytherapy case volume on postimplant dosimetric quality in Pro-Qura proctored programs. Methods and Materials: From August 1999 to December 2008, the computed tomography datasets for 6,600 prostate implants performed by 129 brachytherapists were submitted to Pro-Qura for dosimetric analysis. Brachytherapists were divided into three roughly equal-sized terciles based on total case volume. Postimplant computed tomography scans were obtained at a median of 30 days. Excellent target coverage was defined by a V100 ≥90% and D90 ≥100% minimum prescribed peripheral dose. To determine if the number of excellent implants improved with increasing case numbers, each brachytherapist’s series of implants was bisected into early and late experience by a moveable critical point. Results: For the entire cohort, the mean V100 and D90 were 89.2% and 102.8%, respectively, with 47.7% of the implants scored as excellent. Brachytherapists in the highest-case tercile had a significantly greater fraction of excellent target coverage (57.9%) than did those in the two lower terciles (39.5% and 45.7%, p = 0.015). Twenty-one (25.6%) of the 82 brachytherapists with sufficient case volume for dosimetric improvement analyses demonstrated quality improvement over time. Although there was no significant difference between prostate volume and seed strength, the number of seeds used was significantly greater in adequate implants. Conclusions: The highest-volume brachytherapists were most likely to obtain excellent target coverage. We are encouraged that in general practice, nearly 48% of all implants were scored excellent. It is conceivable that with greater expert third-party involvement, an even greater percentage of cases with excellent target coverage will become reality.

  3. The Effect of Pro-Qura Case Volume on Post-Implant Prostate Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.org [Schiffler Cancer Center Wheeling Jesuit University, Wheeling, WV (United States); Lief, Jonathan H. [Schiffler Cancer Center Wheeling Jesuit University, Wheeling, WV (United States); Grimm, Peter [Prostate Cancer Treatment Center, Seattle, WA (United States); Sylvester, John [Lakewood Ranch Oncology, Bradenton, FL (United States); Butler, Wayne M.; Allen, Zachariah A. [Schiffler Cancer Center Wheeling Jesuit University, Wheeling, WV (United States)

    2011-12-01

    Purpose: To evaluate the effect of prostate brachytherapy case volume on postimplant dosimetric quality in Pro-Qura proctored programs. Methods and Materials: From August 1999 to December 2008, the computed tomography datasets for 6,600 prostate implants performed by 129 brachytherapists were submitted to Pro-Qura for dosimetric analysis. Brachytherapists were divided into three roughly equal-sized terciles based on total case volume. Postimplant computed tomography scans were obtained at a median of 30 days. Excellent target coverage was defined by a V100 {>=}90% and D90 {>=}100% minimum prescribed peripheral dose. To determine if the number of excellent implants improved with increasing case numbers, each brachytherapist's series of implants was bisected into early and late experience by a moveable critical point. Results: For the entire cohort, the mean V100 and D90 were 89.2% and 102.8%, respectively, with 47.7% of the implants scored as excellent. Brachytherapists in the highest-case tercile had a significantly greater fraction of excellent target coverage (57.9%) than did those in the two lower terciles (39.5% and 45.7%, p = 0.015). Twenty-one (25.6%) of the 82 brachytherapists with sufficient case volume for dosimetric improvement analyses demonstrated quality improvement over time. Although there was no significant difference between prostate volume and seed strength, the number of seeds used was significantly greater in adequate implants. Conclusions: The highest-volume brachytherapists were most likely to obtain excellent target coverage. We are encouraged that in general practice, nearly 48% of all implants were scored excellent. It is conceivable that with greater expert third-party involvement, an even greater percentage of cases with excellent target coverage will become reality.

  4. Brain abscess following dental implant placement via crestal sinus lift - a case report.

    Science.gov (United States)

    Manor, Yifat; Garfunkel, Adi A

    2018-01-01

    To describe a rare case of odontogenic brain abscess. A healthy, 35-year-old male had two dental implants placed in a simultaneously augmented maxillary sinus. One implant failed and the patient developed a maxillary sinusitis that failed to improve following antibiotic treatment at home. The neglected sinus infection led to formation of a brain abscess. The patient was hospitalised only when he had pan sinusitis with neurological signs. Symptoms were headache attacks, a subfebrile fever and a purulent secretion from the left nostril. The osteomeatal complex was blocked, the maxillary sinus was filled with pus and the Schneiderian membrane thickened. The patient was treated with intravenous antibiotic treatment. Computerised tomography (CT) and magnetic resonance imaging (MRI) scans and functional endoscopic sinus surgery (FESS), were implemented. When his conditions worsened, the patient underwent a left frontal mini craniotomy. Following the craniotomy and antibiotic treatment, there was a gradual resolution and the patient was dismissed after 2 months in hospital with no neurological deficit or signs of sinusitis. Maxillary sinusitis following dental implant insertion and concomitant maxillary sinus elevation should be treated immediately and thoroughly since untreated sinusitis may cause life-threatening situations such as a brain abscess. In case of severe infection, clinicians should refer immediately the patient to hospital specialists. Conflict-of-interest statement: The authors have stated explicitly that there are no conflicts of interest. The manuscript was self-funded.

  5. Osteonecrosis of the jaw after dental implant placement. A case report

    Directory of Open Access Journals (Sweden)

    J.L. Calvo-Guirado

    2014-03-01

    Full Text Available Background: In the past few years, the occurrence of an oral lesion, called osteonecrosis of the jaw, has increasingly been reported in patients undergoing treatment with systemic bisphosphonates (BPs; however, few papers dealing with oral biphosphonates related osteonecrosis of the jaws (BRONJ can be found in the literature. The purpose of the present case was to report an occurrence of BRONJ after implant insertion. Case report: Ten years ago, eight dental implants were inserted in the jaw of a 65-year-old female. After 5 years of treatment with alendronic acid, a breakdown of the oral mucosa covering the implants occurred with a purulent discharge in the left side of the jaw; periapical radiolucency was present around both distal implants. An en-block resection of the alveolar bone including the two implants was performed. Thirthy-five hyperbaric sessions were taken and no signs of recurrence of the lesion were observed after a follow-up of 20 months. Before the new implant insertion, the patient had suspended the treatment with alendronic acid for 6 months. At the interface of one of the implants, a gap was observed between bone and implant. This bone was non vital, and many osteocyte lacunae were empty. Moreover, this bone appeared to be partially demineralized. Conclusion: There is certainly a temporal association between oral BPs use and development of BRONJ, but a correlation does not necessarily mean causation. In patients undergoing oraltreatment, clinicians must be aware of the increased risk of implant failure.

  6. Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation.

    Science.gov (United States)

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C D; Georgiade, G S

    1996-06-01

    Detection of intracapsular rupture of silicone breast prostheses using MR imaging is often performed by identifying the "linguine sign" [1]. The linguine sign is easily differentiated from simple radial folds that are seen in intact implants. However, more subtle signs of intracapsular rupture, including undulating subcapsular lines and the "teardrop sign," are less often recognized [2-5] and may prove difficult for the less experienced radiologist to differentiate from complex radial folds of intact implants. In this essay, we illustrate the MR imaging findings of complex radial folds in intact implants and compare them with findings of incomplete shell collapse in ruptured implants in a surgically confirmed series of explanted silicone breast prostheses.

  7. Perioprosthetic and Implant-Supported Rehabilitation of Complex Cases: Clinical Management and Timing Strategy.

    Science.gov (United States)

    Landi, Luca; Piccinelli, Stefano; Raia, Roberto; Marinotti, Fabio; Manicone, Paolo Francesco

    2016-01-01

    Treatment of complex perioprosthetic cases is one of the clinical challenges of everyday practice. Only a complete and thorough diagnostic setup may allow the clinician to formulate a realistic prognosis to select the abutments to support prosthetic rehabilitation. Clinical, radiographic, or laboratory parameters used separately are useless to correctly assign a reliable prognosis to single teeth except in the case of a clearly hopeless tooth. Therefore, it is crucial to gather the greatest quantity of data to determine the role that every single element can play in the prosthetic rehabilitation of the case. The following report deals with the management of a multidisciplinary periodontally compromised case in which a treatment strategy and chronology were designed to reach clinical predictability while reducing the duration of the therapy.

  8. Nasopalatine duct cyst associated with dental implant treatment: A case report

    Directory of Open Access Journals (Sweden)

    Shintaro Sukegawa, DDS, PhD

    2015-09-01

    Full Text Available Maxillary anterior implants are associated with the risk of nasopalatine canal damage. Here we present the case of a 37-year-old man who developed a nasopalatine duct cyst after maxillary implant placement. The patient received an implant 3 months after the extraction of a fractured maxillary right central incisor. At a maintenance visit 9 years after the procedure, he complained of swelling and mild pain in the palatal region of the implant. A panoramic radiograph and computed tomography (CT scan revealed a large, well-circumscribed, periapical radiolucency surrounding the apical portion of the implant and extending to the nasopalatine duct. We removed the entire lesion without removing the implant. Histopathologic examination of the resected specimen revealed a nasopalatine duct cyst. Accidental contact with the nasopalatine canal during implant surgery may have led to the development of the nasopalatine duct cyst. Careful planning using a preoperative CT scan prior to implant placement may prevent such complications.

  9. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    Science.gov (United States)

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  10. Perioprosthetic and Implant-Supported Rehabilitation of Complex Cases: Clinical Management and Timing Strategy

    Directory of Open Access Journals (Sweden)

    Luca Landi

    2016-01-01

    Full Text Available Treatment of complex perioprosthetic cases is one of the clinical challenges of everyday practice. Only a complete and thorough diagnostic setup may allow the clinician to formulate a realistic prognosis to select the abutments to support prosthetic rehabilitation. Clinical, radiographic, or laboratory parameters used separately are useless to correctly assign a reliable prognosis to single teeth except in the case of a clearly hopeless tooth. Therefore, it is crucial to gather the greatest quantity of data to determine the role that every single element can play in the prosthetic rehabilitation of the case. The following report deals with the management of a multidisciplinary periodontally compromised case in which a treatment strategy and chronology were designed to reach clinical predictability while reducing the duration of the therapy.

  11. A prospective study on silicone breast implants and the silicone-related symptom complex.

    Science.gov (United States)

    Contant, C M E; Swaak, A J G; Obdeijn, A I M; van der Holt, B; Tjong Joe Wai, R; van Geel, A N; Eggermont, A M M

    2002-06-01

    This cohort study prospectively evaluated the prevalence of the silicone-related symptom complex (SRSC) in relation to antinuclear antibodies (ANA) and magnetic resonance imaging (MRI) of silicone breast implants (SBI) 1 year after implantation. A total of 57 women undergoing mastectomy followed by immediate breast reconstruction (IBR) and SBI between March 1995 and March 1997 at the University Hospital Rotterdam/Daniel den Hoed Cancer Centre, were prospectively evaluated. Just before and 1 year after IBR the sera of these women were tested for the presence of ANA and they were screened for the prevalence of SRSC-related symptoms by questionnaire. All prostheses were evaluated by MRI 1 month and 1 year after IBR. Just before operation 11% of the women had a Sjögren score of more than 2, whereas 30% had such a score 1 year after IBR ( P = 0.01). One year postoperatively women had significantly more RA/Raynaud-related complaints: 21% preoperatively versus 40% 1 year after IBR ( P = 0.03). Within the undefined complaints-related group 19% had a score of 2 or more preoperatively and 33% 1 year after IBR ( P = 0.09). There were no new cases of ANA positivity 1 year after IBR. The linguine sign was seen by MRI in three implants: one 1 month after IBR and two 1 year after IBR. There was no relation to changes in SRSC expression and these MRI findings. In conclusion, 1 year after SBI implantation women had more SRSC-related complaints, especially Sjögren's and RA/Raynaud's. Moreover there was no correlation between elevated SRSC expression and changes in the presence of ANA or changes in MRI of the SBI 1 year after IBR.

  12. Peri-Implant Bone Loss and Peri-Implantitis: A Report of Three Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Vanchit John

    2016-01-01

    Full Text Available Dental implant supported restorations have been added substantially to the clinical treatment options presented to patients. However, complications with these treatment options also arise due to improper patient selection and inadequate treatment planning combined with poor follow-up care. The complications related to the presence of inflammation include perimucositis, peri-implant bone loss, and peri-implantitis. Prevalence rates of these complications have been reported to be as high as 56%. Treatment options that have been reported include nonsurgical therapy, the use of locally delivered and systemically delivered antibiotics, and surgical protocols aimed at regenerating the lost bone and soft tissue around the implants. The aim of this article is to report on three cases and review some of the treatment options used in their management.

  13. Cochlear Implant: the complexity involved in the decision making process by the family.

    Science.gov (United States)

    Vieira, Sheila de Souza; Bevilacqua, Maria Cecília; Ferreira, Noeli Marchioro Liston Andrade; Dupas, Giselle

    2014-01-01

    to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child. qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants). knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant. deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention.

  14. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.

    Science.gov (United States)

    Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio

    2009-01-01

    Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.

  15. Successful implant placement in a Case of Florid Cemento-osseous Dysplasia: a case report and literature review.

    Science.gov (United States)

    Esfahanizadeh, Nasrin; Yousefi, Hila

    2018-02-06

    Florid cemento-osseus dysplasia (FCOD) has been described as a reactive process in which normal bone is replaced by fibrous connective tissues and cementum-like materials. Radiographically it appears as dense, lobulated masses, often occurring bilaterally with symmetric involvement. In this case report a successful implant placement has been reported in a 62-year-old Caucasian woman with a chief complaint of mandibular partial edentulous. Radiographic images showed the bilateral radio-opaque lesions in edentulous regions of mandible, and mandibular anterior teeth alike. All mandibular teeth were vital and no root resorption was detected. The findings of X-ray images were attributable to FCOD. A highly conservative step-by-step two-stage implant surgery was performed. After 6 months the implants loaded with fixed prosthesis. 2, 4,6,12 and 18 months after the surgery radiographic images were taken, which revealed an optimal functional rehabilitation and complete integration of implants. This report confirms that treating the edentulous area near the FCOD lesions could be planned, if conservative and step-by-step implant placement been considered. To the best of our knowledge, a case of FCOD with successful implant placement has not been reported previously. More studies in more patients are needed to confirm results of such a therapeutic modality.

  16. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    Science.gov (United States)

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  17. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification

    Directory of Open Access Journals (Sweden)

    Hamed A. Hamed

    2018-02-01

    Full Text Available AIM: This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. METHODS: Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05. RESULTS: Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. CONCLUSION: It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.

  18. Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification.

    Science.gov (United States)

    Hamed, Hamed A; Marzook, Hamdy A; Ghoneem, Nahed E; El-Anwar, Mohamed I

    2018-02-15

    This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSYS for finite element analysis. The results of finite element analysis were verified against experimental trials results which were statistically analysed using student t-test (level of significance p < 0.05). Implant - abutment complex absorbed the load energy in case of vertical implant better than the case of angulated one. That was reflected on cortical bone stress, while both cases showed stress levels within the physiological limits. Comparing results between FEA and experiment trials showed full agreement. It was found that the tilted implant by 25° can be utilised in the posterior region maxilla for replacing maxillary first molar avoiding sinus penetration. The implant-bone interface and peri-implant bones received the highest Von Mises stress. Implant - bone interface with angulated implant received about 66% more stresses than the straight one.

  19. Cochlear Implant: the complexity involved in the decision making process by the family

    Directory of Open Access Journals (Sweden)

    Sheila de Souza Vieira

    2014-06-01

    Full Text Available OBJECTIVE: to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child.METHOD: qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants.RESULTS: knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant.CONCLUSION: deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention.

  20. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature

    Directory of Open Access Journals (Sweden)

    Emne Hammoud Gumieiro

    Full Text Available CONTEXT AND OBJECTIVE: Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. TYPE OF STUDY: Case report, Universidade Federal de São Paulo (UNIFESP. METHODS: A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. RESULTS: The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. CONCLUSION: The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity

  1. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    Science.gov (United States)

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  2. Progressive immediate loading of a perforated maxillary sinus dental implant: a case report

    Directory of Open Access Journals (Sweden)

    Al-Juboori MJ

    2015-01-01

    Full Text Available Mohammed Jasim Al-Juboori Department of Oral Surgery, MAHSA University, Kuala Lumpur, Malaysia Abstract: The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used, involving immediately loaded implants with maxillary sinus perforation and low primary stability. Follow-up was performed with resonance frequency analysis and compared with an implant placed adjacent in the upper second premolar area using a conventional delayed loading protocol. Implants with maxillary sinus involvement showed increasing stability during the healing period. We found that progressive implant loading may be a safe technique for the placement of immediately loaded implants with maxillary sinus involvement. Keywords: progressive implant loading, resonance frequency analysis, implant stability, provisional crown, bone density, maxillary sinus

  3. Utility of 3D printed temporal bones in pre-surgical planning for complex BoneBridge cases.

    Science.gov (United States)

    Mukherjee, Payal; Cheng, Kai; Flanagan, Sean; Greenberg, Simon

    2017-08-01

    With the advent of single-sided hearing loss increasingly being treated with cochlear implantation, bone conduction implants are reserved for cases of conductive and mixed hearing loss with greater complexity. The BoneBridge (BB, MED-EL, Innsbruck, Austria) is an active fully implantable device with no attenuation of sound energy through soft tissue. However, the floating mass transducer (FMT) part of the device is very bulky, which limits insertion in complicated ears. In this study, 3D printed temporal bones of patients were used to study its utility in preoperative planning on complicated cases. Computed tomography (CT) scans of 16 ears were used to 3D print their temporal bones. Three otologists graded the use of routine preoperative planning provided by MED-EL and that of operating on the 3D printed bone of the patient. Data were collated to assess the advantage and disadvantage of the technology. There was a statistically significant benefit in using 3D printed temporal bones to plan surgery for difficult cases of BoneBridge surgery compared to the current standard. Surgeons preferred to have the printed bones in theatre to plan their drill sites and make the transition of the planning to the patient's operation more precise. 3D printing is an innovative use of technology in the use of preoperative planning for complex ear surgery. Surgical planning can be done on the patient's own anatomy which may help to decrease operating time, reduce cost, increase surgical precision and thus reduce complications.

  4. Crohn’s disease and Trabecular Metal implants: a report of two cases and literature review

    Directory of Open Access Journals (Sweden)

    C. Peron

    2015-10-01

    Full Text Available Aim The aim of the present study was to report two cases with Crohn’s disease in whom dental implants successfully osseointegrated and remained functionally stable up to 13 and 12 months of follow-up, respectively. Cases presentation In cases 1 (age 35 years and 2 (age 36 years, tooth 24 and 14, respectively, were atraumatically extracted and a particulated bone grafting material (buccal and palatal aspect of the defect and a Trabecular Metal implant (11.5 mm length, 4.7 mm diameter were inserted in each extraction socket. After implant placement and abutment connection with the final torque (25 Ncm, the provisional restoration was adapted in the oral cavity creating the emergence profile. The provisional crown was screw-retained and had slight occlusal contacts in the centric occlusion (intercuspation position. A periapical radiograph was taken as a control radiograph at the baseline. Postoperatively, antibiotics were prescribed as well as analgesics and an oral rinse was recommended. In both cases, the provisional restoration was removed after 2 weeks and replaced with a full ceramic restoration. Case-1 and case-2 were followed up after 13 months and 12 months respectively. In both cases postoperative healing was uneventful and radiographs taken at follow-up showed no evidence of crestal bone loss. Implants in both cases demonstrated an excellent clinical condition at follow-up. Conclusion Trabecular Metal implants can osseointegrate and remain functionally stable in patients with Crohn’s disease.

  5. Effective implantation of light emitting centers by plasma immersion ion implantation and focused ion beam methods into nanosized diamond

    International Nuclear Information System (INIS)

    Himics, L.; Tóth, S.; Veres, M.; Tóth, A.; Koós, M.

    2015-01-01

    Highlights: • Characteristics of nitrogen implantation of nanodiamond using two low ion energy ion implantation methods were compared. • Formation of complex nitrogen-related defect centers was promoted by subsequent helium implantation and heat treatments. • Depth profiles of the implanted ions and the generated vacancies were determined using SRIM calculations. • The presence of nitrogen impurity was demonstrated by Fourier-transform infrared spectroscopic measurements. • A new nitrogen related band was detected in the photoluminescence spectrum of the implanted samples that was attributed to the N3 color center in nanodiamond. - Abstract: Two different implantation techniques, plasma immersion ion implantation and focused ion beam, were used to introduce nitrogen ions into detonation nanodiamond crystals with the aim to create nitrogen-vacancy related optically active centers of light emission in near UV region. Previously samples were subjected to a defect creation process by helium irradiation in both cases. Heat treatments at different temperatures (750 °C, 450 °C) were applied in order to initiate the formation of nitrogen-vacancy related complex centers and to decrease the sp 2 carbon content formed under different treatments. As a result, a relatively narrow and intensive emission band with fine structure at 2.98, 2.83 and 2.71 eV photon energies was observed in the light emission spectrum. It was assigned to the N3 complex defect center. The formation of this defect center can be expected by taking into account the relatively high dose of implanted nitrogen ions and the overlapped depth distribution of vacancies and nitrogen. The calculated depth profiles distribution for both implanted nitrogen and helium by SRIM simulation support this expectation

  6. Dental implants for severely atrophied jaws due to ectodermal dysplasia

    Directory of Open Access Journals (Sweden)

    Preetha Balaji

    2015-01-01

    Full Text Available The aim was to present the successful esthetical and functional rehabilitation of partial anodontia in a case of severe ectodermal dysplasia with complete atrophy of the jaws. A 17-year-old male with Class III malocclusion with partial anodontia sought dental implant treatment. His expectation was that of Class I occlusion. The challenge in the case was to match the expectation, reality, and the clinical possibilities. Ridge augmentation was performed with a combination of rib graft and recombinant human bone morphogenetic protein-2. Simultaneously, 6 implants (Nobel Biocare™ - Tapered Groovy were placed in maxillary arch and 10 in the mandible. Simultaneous placement ensured faster and better osseointegration though a mild compromise of the primary stability was observed initially. After adequate healing, Customized Zirconia Procera™ system was used to build the framework. Zirconia crown was cemented to the framework. Radiological and clinical evidence of osseointegration was observed in all 16 dental implants. Successful conversion of Class III to Class I occlusion was achieved with the combination of preprosthetic alveolar ridge augmentation, Procera™ Implant Bridge system. Abnormal angulations and or placement of dental implants would result in failure of the implant. Hence conversion of Class III to Class I occlusion needs complete and complex treatment planning so that the entire masticatory apparatus is sufficiently remodeled. Planning should consider the resultant vectors that would otherwise result in failure of framework or compromise the secondary stability of the dental implant during function. A successful case of rehabilitation of complex partial anodontia is presented.

  7. A new spiral dental implant: a tool for oral rehabilitation of difficult cases.

    Science.gov (United States)

    Balan, I; Calcaterra, R; Lauritano, D; Grecchi, E; Carinci, F

    2017-01-01

    Spiral dental implant (SDI) is an implant with a conical internal helix that confers the characteristic of self-drilling, self-tapping, and self-bone condensing. These proprieties offer better control during insertion of SDI giving a high primary stabilization, even in poor quality bone. A shorter diameter of SDI results in reduced drilling during insertion and consequently less trauma and minimal bone loss. To address the research purpose, the investigators designed a retrospective cohort study. The study population was composed of 25 patients, 11 males and 14 females that have been treated by Dr. Balan with 187 SDI positioned in mandible and into maxilla bone. The implants were placed during the years 2013 to 2014 in Dr. Balan clinic. All patients underwent the same surgical protocol. Several variables are investigated: demographic (age and gender), anatomic (upper/lower jaws and tooth site), implant (length and diameter and type) variables, edentulism (partial or total), and comorbid status of health (i.e.: hypothyroidism, parodontitis, hypertension, diabetes, presence of cancer, heart disease, hepatitis and rheumatologic disease). Pearson Chi-Square test was used to investigate variables and p < 0.05 was considered statistically significant. Statistically it has been shown that females have a higher possibility of unsuccessful respect of male, with a "p value" of 0.014. Another important impact factor for success of implant insertion has been represented by concomitants pathologies: cancer represents the most negative high factor risk with a percentage of unsuccessful of 50%, followed by heart disease (15%), and diabetes (3.7%). SDIs are reliable tools for difficult cases of oral rehabilitation. They have a higher success and survival rate, which means stable results over time. No differences were detected among SDI lengths, implant/crown ratio. In addition, the insertion of SDIs in banked bone can be performed without adverse effects. Finally, flapless and

  8. Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging

    International Nuclear Information System (INIS)

    Acikel, Volkan; Atalar, Ergin; Uslubas, Ali

    2015-01-01

    Purpose: The authors’ purpose is to model the case of an implantable pulse generator (IPG) and the electrode of an active implantable medical device using lumped circuit elements in order to analyze their effect on radio frequency induced tissue heating problem during a magnetic resonance imaging (MRI) examination. Methods: In this study, IPG case and electrode are modeled with a voltage source and impedance. Values of these parameters are found using the modified transmission line method (MoTLiM) and the method of moments (MoM) simulations. Once the parameter values of an electrode/IPG case model are determined, they can be connected to any lead, and tip heating can be analyzed. To validate these models, both MoM simulations and MR experiments were used. The induced currents on the leads with the IPG case or electrode connections were solved using the proposed models and the MoTLiM. These results were compared with the MoM simulations. In addition, an electrode was connected to a lead via an inductor. The dissipated power on the electrode was calculated using the MoTLiM by changing the inductance and the results were compared with the specific absorption rate results that were obtained using MoM. Then, MRI experiments were conducted to test the IPG case and the electrode models. To test the IPG case, a bare lead was connected to the case and placed inside a uniform phantom. During a MRI scan, the temperature rise at the lead was measured by changing the lead length. The power at the lead tip for the same scenario was also calculated using the IPG case model and MoTLiM. Then, an electrode was connected to a lead via an inductor and placed inside a uniform phantom. During a MRI scan, the temperature rise at the electrode was measured by changing the inductance and compared with the dissipated power on the electrode resistance. Results: The induced currents on leads with the IPG case or electrode connection were solved for using the combination of the MoTLiM and

  9. Cochlear Implant: the complexity involved in the decision making process by the family1

    Science.gov (United States)

    Vieira, Sheila de Souza; Bevilacqua, Maria Cecília; Ferreira, Noeli Marchioro Liston Andrade; Dupas, Giselle

    2014-01-01

    Objective to understand the meanings the family attributes to the phases of the decision-making process on a cochlear implant for their child. Method qualitative research, using Symbolic Interactionism and Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semistructured interview. Nine families participated in the study (32 participants). Results knowledge deficit, difficulties to contextualize benefits and risks and fear are some factors that make this process difficult. Experiences deriving from interactions with health professionals, other cochlear implant users and their relatives strengthen decision making in favor of the implant. Conclusion deciding on whether or not to have the implant involves a complex process, in which the family needs to weigh gains and losses, experience feelings of accountability and guilt, besides overcoming the risk aversion. Hence, this demands cautious preparation and knowledge from the professionals involved in this intervention. PMID:25029052

  10. REHABILITATION OF SEVERELY ATROPHIED UPPER JAW WITH INTRAOSSAL DENTAL IMPLANTS - clinical case

    Directory of Open Access Journals (Sweden)

    Ivan Chenchev

    2010-07-01

    Full Text Available Objective: The purpose of this presentation is to show the difficulty in prosthetization of a clinical case with a pronounced atrophy of the upper jaw and the various types and nature of restrictions imposed by the requirements of the patient. Methods: The clinical analysis, surgical protocol and prosthetic solution are presented in the treatment of 72 year-old woman with a pronounced atrophy of the upper jaw. OPG, standard CT of the upper jaw was used in the planning and a special surgical template was fabricated, helping us to find intraoperatively the exact locations of implants. The preliminary analysis of the number, height and diameter of intraossal implants helped us to find the exact prosthetic solution in this clinical case. The preparation of the implant bed was done by conical osteotomy in order to expand and condense the existing bone, which allowed us to use endoossal implants with a possible maximum size in a very limited maxillary volume and the reluctance of the patient to use other methods and surgical techniques. Conical threaded and self-tapping intraossal implants were used, placed according to a classic two-stage methodology with a flap and a long-term functional loading after a period of four months.Results and Conclusion: The applied surgical and prosthetic solution allowed us to achieve a good functional and aesthetic rehabilitation in this case of severe atrophy of the upper jaw, following a number of restrictions imposed on us by the reluctance of the patient to use other surgical solutions. This shows that in the case of severe atrophy of the upper jaw, a good clinical result can be achieved. For this reason, the use of CT,a well-planned surgical template, sufficient preparation ,the maximum use of available bone volume and the choice of a good prosthetic solution is very important.

  11. Etonogestrel implant migration to the vasculature, chest wall, and distant body sites: cases from a pharmacovigilance database.

    Science.gov (United States)

    Kang, Sarah; Niak, Ali; Gada, Neha; Brinker, Allen; Jones, S Christopher

    2017-12-01

    To describe clinical outcomes of etonogestrel implant patients with migration to the vasculature, chest wall and other distant body sites spontaneously reported to the US Food and Drug Administration Adverse Event Reporting System (FAERS) database. We performed a standardized Medical Dictionary for Regulatory Activities (MedDRA) query in the FAERS database (through November 15, 2015), with reports coded with one or more MedDRA preferred terms that indicate complications with device placement or migration of the device from the original site of insertion to the vasculature, chest wall and other distant body sites. We excluded any cases previously described in the medical literature. We identified 38 cases of pronounced etonogestrel implant migration. Migration locations included the lung/pulmonary artery (n=9), chest wall (n=1), vasculature at locations other than the lung/pulmonary artery (n=14) and extravascular migrations (n=14) to other body sites (e.g., the axilla and clavicle/neck line/shoulder). The majority of cases were asymptomatic and detected when the patient desired implant removal; however, seven cases reported symptoms such as pain, discomfort and dyspnea in association with implant migration. Three cases also describe pulmonary fibrosis and skin reactions as a result of implant migration to the vasculature, chest wall and other distant body sites. Sixteen cases reported surgical removal in an operating room setting. Our FAERS case series demonstrates etonogestrel implant migration to the vasculature, chest wall and other body sites distant from the site of original insertion. As noted by the sponsor in current prescribing information, a key determinant in the risk for etonogestrel contraceptive implant migration appears to be improper insertion technique. Although migration of etonogestrel implants to the vasculature is rare, awareness of migration and education on proper insertion technique may reduce the risk. Published by Elsevier Inc.

  12. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    Science.gov (United States)

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  13. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  14. Permanent pace maker implantation through axillary vein approach

    International Nuclear Information System (INIS)

    Shah, B.; Hussain, C.; Awan, Z.A.

    2017-01-01

    Device implantation is an integral part of interventional cardiology particularly electrophysiology. In this study, we are going to share our experience of device implantation technique at electrophysiology department Hayatabad Medical Complex, Peshawar. Methods: the study was conducted from June 2011 to December 2015. Axillary vein was used to implant the devices but in some cases when this rout was not convenient due to any reason then subclavian vein was entered through the Seldinger technique. Fluoroscopy time was less than 10 minutes and total procedure time was not more than 45 minutes. Electric cautery was used only in two cases. Pressure dressing was used in a few cases. Results: Total numbers of permanent pacemakers (PPM) remain 800 during the study period. There were 450 single chamber pacemakers and 350 dual chambers pacemakers. No case of any major bleeding was documented and in very few cases there was mild ooze from the procedure site after the operation which was tackled with pressure dressing. Four cases of pneumothorax were noted during the study period and in three cases chest intubation were done and one patient was kept on conservative management. Patient were followed after one month of discharge from the hospital and then yearly. Eight cases of lead dislodgment were documented during the study period. Conclusion: Axillary vein approach for implantation of permanent pacemakers is a safe and less time-consuming technique. (author)

  15. Custom-made, root-analogue direct laser metal forming implant: a case report.

    Science.gov (United States)

    Mangano, Francesco Guido; Cirotti, Bruno; Sammons, Rachel Lilian; Mangano, Carlo

    2012-11-01

    In the last few years, the application of digital technology in dentistry has become widespread with the introduction of cone beam computed tomography (CBCT) scan technology, and considerable progress has been made in the development of computer-aided design/ computer-aided manufacturing (CAD/CAM) techniques, including direct laser metal forming (DLMF). DLMF is a technology which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. At present, the combined use of CBCT 3D data and CAD/CAM technology makes it possible to manufacture custom-made, root-analogue implants (RAI) with sufficient precision. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CBCT images of a non-restorable right maxillary first premolar were acquired and transformed into a 3D model. From this model, a custom-made, root-analogue DLMF implant was fabricated. Immediately after tooth extraction, the RAI with a pre-operatively designed abutment was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the RAI showed a good functional and aesthetic integration. The introduction of DLMF technology signals the start of a new revolutionary era for implant dentistry as its immense potential for producing highly complex macro- and microstructures is receiving vast interest in different medical fields.

  16. Fluorouracil implants caused a diaphragmatic tumor to be misdiagnosed as liver metastasis: a case report

    International Nuclear Information System (INIS)

    Shen, Yang-Yang; Qin, Hong-Wei; Zhang, Jian-Bo; Wang, Zhen-Dan; Li, Pang; Pang, Kai; Zhang, Bo; Li, Sheng; Cui, Kai

    2016-01-01

    Fluorouracil implants are widely used in peritoneal interstitial chemotherapy. Curative effects have been obtained, but implants have also caused some complications. We performed an analysis of a 66-year-old male patient’s case history, as well as conventional pathological analysis and Raman spectroscopic detection of the diaphragmatic tumor. We also analyzed the underlying causes of this condition to prevent complications and reduce misdiagnoses in future cases. The patient had a history of peritoneal fluorouracil implantation. Pathological analysis of the diaphragmatic mass revealed foreign particles, and Raman detection showed that the mass contained fluorouracil. Fluorouracil implants may persist due to the high concentrations of this drug used in peritoneal chemotherapy. This finding should provide guidance and improve the application of peritoneal implants. In clinical trials, and the diagnosis of liver metastasis should be based on pathological results

  17. Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.

    Science.gov (United States)

    Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S

    2017-01-01

    The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.

  18. Complex systematic review - Perioperative antibiotics in conjunction with dental implant placement.

    Science.gov (United States)

    Lund, Bodil; Hultin, Margareta; Tranaeus, Sofia; Naimi-Akbar, Aron; Klinge, Björn

    2015-09-01

    The aim of this study was to revisit the available scientific literature regarding perioperative antibiotics in conjunction with implant placement by combining the recommended methods for systematic reviews and complex systematic reviews. A search of Medline (OVID), The Cochrane Library (Wiley), EMBASE, PubMed and Health technology assessment (HTA) organizations was performed, in addition to a complementary hand-search. Selected systematic reviews and primary studies were assessed using GRADE and AMSTAR, respectively. A meta-analysis was performed. The literature search identified 846 papers of which 10 primary studies and seven systematic reviews were included. Quality assessment of the systematic reviews revealed two studies of moderate risk of bias and five with high risk of bias. The two systematic reviews of moderate risk of bias stated divergent numbers needed to treat (NNT) to prevent one patient from implant failure. Four of the primary studies comparing antibiotic prophylaxis with placebo were estimated to be of low, or moderate, risk of bias and subjected to meta-analysis. The NNT was 50 (pooled RR 0.39, 95% CI 0.18, 0.84; P = 0.02). None of these four studies individually show a statistical significant benefit of antibiotic prophylaxis. Furthermore, narrative analysis of the studies eligible for meta-analysis reveals clinical heterogeneity regarding intervention and smoking. Antibiotic prophylaxis in conjunction with implant placement reduced the risk for implant loss by 2%. However, the sub-analysis of the primary studies suggests that there is no benefit of antibiotic prophylaxis in uncomplicated implant surgery in healthy patient. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Ultrasonic implant site preparation using piezosurgery: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

    Science.gov (United States)

    Vercellotti, Tomaso; Stacchi, Claudio; Russo, Crescenzo; Rebaudi, Alberto; Vincenzi, Giampaolo; Pratella, Umberto; Baldi, Domenico; Mozzati, Marco; Monagheddu, Chiara; Sentineri, Rosario; Cuneo, Tommaso; Di Alberti, Luca; Carossa, Stefano; Schierano, Gianmario

    2014-01-01

    This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).

  20. Effects of energy variations of ions influencing a target on implantation

    International Nuclear Information System (INIS)

    Astakhov, V.P.; Rubtsov, V.A.; Aranovich, R.M.; Pavlov, P.V.

    1981-01-01

    In cases of phosphorus and boron ion implantation into silicon the dependence of electrophysical properties of ion-doped layers and target material near the layer boundaries on energy variation conditions of influencing ions is observed. A physical model explaining the dependence is proposed. It is found that for the target, being at room temperature, after successive annealing the qualitative characteristics of conditions (i.e. energy increase and decrease) on implantation of phosphorus ions into p-silicon and boron ions into n-silicon, as well as the value of energy stages, define rhosub(l) ion-doped layer resistivity and tausub(mc) nonequilibrium minority carrier lifetime in the base of p-n transitions. The essence of the effects observed is that for equal sets of Esub(i) ion energy values and PHIsub(i) corresponding phases at maximum energy used exceeding 30 keV, successive energy increase during implantation, when E 1 2 1 mode), leads to smaller rhosub(e) values and greater tausub(mc) than in case of successive energy decrease, when E 1 >E 2 >...E(E 2 mode) for any fixed annealing temperature. In cases when the maximum energy does not exceed 30 KeV, the E 1 and E 2 modes lead to analogous rhosub(e) and tausub(mc) values. The E 2 mode leads to enrichment of the ion-implanted layer with associations and complexes on the basis of interstitial atoms in comparison with the E 1 mode. The associations and complexes on thermal treatment are reformed into the higher-temperature interstitial complexes increasing rhosub(e) and decreasing tausub(mc). Supposition about the effect of these complexes and processes of structural transformations on annealing, hampering-improvement of structural properties of the ion-implanted layer and a crystal region bordered on it [ru

  1. Immediate loading of titanium hexed screw-type implants in the edentulous patient: case report.

    Science.gov (United States)

    Calvo, M P; Muller, E; Garg, A K

    2000-01-01

    Histologic and histomorphometric studies in both animals and humans have shown that more rapid and greater bone-to-implant contact can be achieved with implants that incorporate certain surface characteristics compared with the original machined-surface implants. Such findings are significant because various implant designs may allow the fixtures to sufficiently resist functional loading sooner than originally thought. The case report presented here indicates that immediate loading of hexed titanium screw-type implants in the anterior mandible can lead to successful osseointegration and clinical outcome. The number of implants placed, their distribution, and the type of rigid connection are critical considerations for immediate loading. A bone height that can accommodate dental implants > or = 10 mm long is recommended. Biomechanically, the implants to be immediately loaded must be stable and resistant to macromovement to ensure good osseointegration.

  2. Fabrication of a Customized Ball Abutment to Correct a Nonparallel Implant Abutment for a Mandibular Implant-Supported Removable Partial Prosthesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Hossein Dasht

    2017-12-01

    Full Text Available Introduction: While using an implant-supported removable partial prosthesis, the implant abutments should be parallel to one another along the path of insertion. If the implants and their attachments are placed vertically on a similar occlusal plane, not only is the retention improved, the prosthesis will also be maintained for a longer period. Case Report: A 65-year-old male patient referred to the School of Dentistry in Mashhad, Iran with complaints of discomfort with the removable partial dentures for his lower mandible. Due to the lack of parallelism in the supporting implants, prefabricated ball abutment could not be used. As a result, a customized ball abutment was fabricated in order to correct the non-parallelism of the implants. Conclusion: Using UCLA abutments could be a cost-efficient approach for the correction of misaligned implant abutments in implant-supported overdentures.

  3. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature.

    Science.gov (United States)

    Berlin, Eva; Singh, Kunwar; Mills, Christopher; Shapira, Ilan; Bakst, Richard L; Chadha, Manjeet

    2018-01-01

    We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging). The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma.

  4. Suspected bacterial endophthalmitis following sustained-release dexamethasone intravitreal implant: a case report.

    Science.gov (United States)

    Arıkan Yorgun, Mücella; Mutlu, Melek; Toklu, Yasin; Cakmak, Hasan Basri; Cağıl, Nurullah

    2014-06-01

    A 58-year-old man admitted to our opthalmology department with the complaint of branch retinal vein occlusion. He was treated with intravitreal Ozurdex in the right eye. Two days after the injection, the patient presented with ocular pain and the visual acuity was hand movement. A diagnosis of endophthalmitis was made. We performed emergent pars plana vitrectomy (PPV) and the implant was removed from the vitreous cavity using a retinal forceps. A combination of vancomycin 1.0 mg and amikacin 0.4 mg was injected intravitreally. However, because of the blurring in the vitreus one week after the procedure, phacoemulsification and a repeat PPV was performed. Five days after the last procedure the signs and symptoms of endophthalmitis were resolved. Our case demonstrated that endophthalmitis could develop after intravitreal implantation of Ozurdex. Surgical removal of the implant and immediate vitrectomy seems to be a useful treatment option in these cases.

  5. The Diagon/Gel Implant: A Preliminary Report of 894 Cases

    Directory of Open Access Journals (Sweden)

    Constantin Stan, MD

    2017-07-01

    Full Text Available Background:. The breast has always been perceived as the emblem of femininity. Desire of having an ideal breast form has been of interest for a long time. Methods:. This preliminary article is a retrospective analysis of 894 cases of breast augmentation with Diagon/Gel breast implants covered with a micropolyurethane foam (Microthane. The surgical technique employed is a modified dual plane, which enables us to use a new anatomical implant to move the glandular parenchyma into a higher position. Results:. The study extended from January 2010 to September 2015, during which no breast implant developed Baker grade III or IV capsular contracture (CC and only a few adverse events occurred. Patients reported to be highly satisfied with the final outcome, which was very natural both in the form and movement. Conclusions:. The new concept of Diagon/Gel represents the next step in the evolutionary progress of breast implants and allows the surgeon to perform not only a breast augmentation but also parenchymal elevation, which otherwise would have required a mastopexy, and we have called it breast enhancement.

  6. Removable Partial Denture Supported by Implants with Prefabricated Telescopic Abutments - A Case Report

    Science.gov (United States)

    Sehgal, Komal

    2014-01-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy—biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. PMID:25121066

  7. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    Science.gov (United States)

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  8. Treatment of 9 cases of pulmonary atelectasis caused by endobronchial tuberculosis with intraluminal stent implantation

    International Nuclear Information System (INIS)

    Ji Hongjiang; Li Qiang; Liu Zhongling; Bai Chong; Yao Xiaopeng; Zhao Lijun; Xu Hao; Dong Yuchao; Huang Haidong; Wang Qin

    2007-01-01

    Objective: To evaluate the effect and safety of intraluminal stent implantation in the treatment of complete airway obstruction with unilateral pulmonary atelectasis caused by endobronchial tuberculosis (EBTB). Methods: 9 cases of pulmonary atelectasis caused by EBTB were treated with high- frequency electricity/microwave, balloon dilation and endobronchial stent implantation. At the time of 1 week and 4-6 months after stenting ,the diameters of stenotic segment were measured. Results: All 9 cases with atelectasis of EBTB showed complete re-expansion within 3 days after the stent implantation. The mean diameter of the stenotic segments of 9 EBTB patients increased to 9.17 ± 1.24 mm at 7th day after stent implantation; 3 of 9 EBTB patients occured mild restenosis after implantation of tracheobronchial stents. However, combination therapy of cryotherapy and balloon dilation can effectively prevent the aggravation of restenosis. Conclusion: Comparing with traditional surgical treatment, the intraluminal stent implantation for atelectasis caused by EBTB is a new, effective, safe and microtraumatic method with reliable preservation of pulmonary function. (authors)

  9. Modality and risk management for orthodontic extrusion procedures in interdisciplinary treatment for generating proper bone and tissue contours for the planned implant: a case report.

    Science.gov (United States)

    Maeda, Sachiko; Sasaki, Takeshi

    2015-12-01

    In adult interdisciplinary treatments with using dental implants, limited orthodontic treatment, especially orthodontic extrusion (OE), offers many benefits by both correcting teeth alignment and by contributing to the regeneration of periodontal tissues. However, orthodontic procedures carry some risks and unpredictabilities that might compromise tooth and/or periodontal tissue health. Especially in complex cases, it is difficult to decide which orthodontic treatment modalities should be combined, in what sequences they should be applied, and what their force systems and treatment times are.To achieve optimum results, some cases require two or more OEs to the same site being carried out at different times while taking the treatment effects into consideration. Such staged OE offers minimum intervention and maximum efficiency. In this case report, OE was first applied for orthodontic extraction. After bone regeneration followed by an implant placement and another surgical operation, a second OE was applied to align the inclination of an adjacent tooth. As a result, a predictable prognosis of implants as well as greatly improved esthetics and periodontal tissue health were achieved.

  10. Autologous chondrocyte implantation for cartilage injury treatment in Chiang Mai University Hospital: a case report.

    Science.gov (United States)

    Wongtriratanachai, Prasit; Pruksakorn, Dumnoensun; Pothacharoen, Peraphan; Nimkingratana, Puwapong; Pattamapaspong, Nuttaya; Phornphutkul, Chanakarn; Setsitthakun, Sasiwariya; Fongsatitkul, Ladda; Phrompaet, Sureeporn

    2013-11-01

    Autologous chondrocyte implantation (ACI) has become one of the standard procedures for articular cartilage defect treatment. This technique provides a promising result. However the procedural process requires an approach of several steps from multidisciplinary teams. Although the success of this procedure has been reported from Srinakharinvirot University since 2007, the application of ACI is still limited in Thailand due to the complexity of processes and stringent quality control. This report is to present the first case of the cartilage defect treatment using the first generation-ACI under Chiang Mai University's (CMU) own facility and Ethics Committee. This paper also reviews the process of biotechnology procedures, patient selection, surgical, and rehabilitation techniques. The success of the first case is an important milestone for the further development of the CMU Human Translational Research Laboratory in near future.

  11. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Eva Berlin

    2018-01-01

    Full Text Available We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging. The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma.

  12. Peri-implantitis: a complex condition with non-linear characteristics

    NARCIS (Netherlands)

    Papantonopoulos, G.H.; Gogos, C.; Housos, E.; Bountis, T.; Loos, B.G.

    2015-01-01

    Aim To cluster peri-implantitis patients and explore non-linear patterns in peri-implant bone levels. Materials and Methods Clinical and radiographic variables were retrieved from 94 implant-treated patients (340 implants, mean 7.1 ± 4.1 years in function). Kernel probability density estimations on

  13. Rehabilitation of resorbed mandibular ridges using mini implant retained overdentures: A case series with 3 year follow-up

    Directory of Open Access Journals (Sweden)

    Pooja Kumari

    2016-01-01

    Full Text Available With the increasing average life expectancy of human beings, the need to cater geriatric patients is ever increasing. Complete dentures are an indispensable tool in this regard. The loose and unstable lower complete denture owing to residual ridge resorption is one of the most common problems faced by edentulous patients. Dental implant retained overdentures have emerged as an efficient treatment modality for such patients. Though useful, not every patient is a suitable candidate to go for conventional implant-borne prosthesis, limitation being the available bone width. In such cases, mini implants may be used for augmenting the retention of the dentures and improving the quality of life of patients. In this case series, rehabilitation of three compromised cases with mini implant retained overdentures have been described wherein patients are experiencing instability of lower denture due to thin resorbed mandibular ridges. In one of the cases, three mini implants placed in A, C, and E position were splinted using a cemented bar to retain the mandibular denture. The other two cases were rehabilitated using unsplinted ball type one piece mini implants placed in A, C, and E position in one case and B and D position in another case. Though splinted bar design should be preferred but the lack of available vertical space precluded the utilization of bar in other two cases. The results were found to be satisfactory with no complications reported during a follow-up period of over 3 years in all the cases.

  14. Fabrication of a Customized Ball Abutment to Correct a Nonparallel Implant Abutment for a Mandibular Implant-Supported Removable Partial Prosthesis: A Case Report

    OpenAIRE

    Hossein Dasht; Mohammadreza Nakhaei; Nafiseh teimouri

    2017-01-01

    Introduction: While using an implant-supported removable partial prosthesis, the implant abutments should be parallel to one another along the path of insertion. If the implants and their attachments are placed vertically on a similar occlusal plane, not only is the retention improved, the prosthesis will also be maintained for a longer period. Case Report: A 65-year-old male patient referred to the School of Dentistry in Mashhad, Iran with complaints of discomfort with the removable partial ...

  15. Rehabilitation of Posterior Maxilla with Zygomatic and Dental Implant after Tumor Resection: A Case Report

    Directory of Open Access Journals (Sweden)

    Faysal Ugurlu

    2013-01-01

    Full Text Available Zygomatic implants have been used for dental rehabilitation in patients with insufficient bone in the posterior upper jaw, due to, for example, tumor resection, trauma, or atrophy. Zygomatic implants are an alternative to complex free or vascularized bone grafting and distraction osteogenesis. A 42-year-old male patient with a severe defect in the right posterior maxilla, starting from the first canine region, which had occurred after tumor resection 3 years earlier, was referred to our department. One zygomatic implant (Brenemark System, Nobel Biocare, Goteborg, Sweden to the zygoma and one dental implant to the canine region were placed. After a 5-month osseointegration period, a fixed denture was fabricated and adapted to the implants. Although the surgical and prosthetic procedures for zygoma implants are not easy, the final outcomes can be successful with appropriate planning.

  16. A case report: the first successful cochlear implant in Uganda.

    African Journals Online (AJOL)

    A case report: the first successful cochlear implant in Uganda. Richard Byaruhanga1, J. ... The patient was a 23 year old male whose presenting com- plaint was inability to .... Custom Sound by Cochlear (the company that manu- factures the ...

  17. Surgical Treatment of Peri-Implantitis: A 17-Year Follow-Up Clinical Case Report

    Directory of Open Access Journals (Sweden)

    Fabrizio Bassi

    2015-01-01

    Full Text Available The purpose of the present case report was to describe the surgical treatment of a peri-implantitis lesion associated with a regenerative approach. A 48-year-old patient came to authors’ attention 36 months after the placement of a dental implant (ITI-Bonefit Straumann, Waldenburg, Switzerland in position 46. A swelling of the peri-implant soft tissues was observed, associated with bleeding on probing and probing depth > 10 mm. A significant peri-implant bone loss was clearly visible on the periapical radiograph. A nonsurgical periodontal supportive therapy was firstly conducted to reduce the inflammation, followed by the surgical treatment of the defect. After mechanical and chemical decontamination with tetracycline solution, a regenerative approach consisting in the application of deproteinized bovine bone mineral (Bio-Oss, Geistlich Pharma AG, Wolhusen, Switzerland and a collagen membrane (Bio-Gide, Geistlich Pharma AG, Wolhusen, Switzerland was performed. An antibiotic therapy was associated with the treatment. The 17-year follow-up showed a physiological probing depth with no clinical signs of peri-implant inflammation and bleeding on probing. No further radiographic bone loss was observed. The treatment described in the present case report seemed to show improved clinical results up to a relevant follow-up period.

  18. Comparison of outcomes in a case of bilateral cochlear implantation using devices manufactured by two different implant companies (Cochlear Corporation and Med-El).

    Science.gov (United States)

    Withers, S J; Gibson, W P; Greenberg, S L; Bray, M

    2011-05-01

    This paper reports a case of a patient who has had bilateral cochlear implants that have been manufactured by different cochlear implant companies (Cochlear Corporation and Med-El). Comparison of speech perception tests following single implant insertion and bilateral insertion (3 and 12 months). The patient was also interviewed to obtain a subjective opinion on their quality of hearing. The patient reported that their Med-El implant had better sound quality than their Cochlear Corporation implant. The speech perception tests however failed to show any difference. Despite no difference found with the objective tests hearing is very subjective and therefore the patient's opinion on the quality of sound is important. It is only a matter of time before other patients are fitted with bilateral cochlear implants from different companies and this information should be collated to allow comparison between manufacturers.

  19. Treatment Approach to Severe Microgenia Cases: Combined Use of Osseous and Implant Genioplasty.

    Science.gov (United States)

    Findikcioglu, Kemal; Sibar, Serhat; Gulsen, Ayse

    2018-03-01

    As well as the chin is an important esthetic unit of the facial structure, it is also the region having a key role in the appearance of the face. Correction of cosmetic and functional deformities that may occur in this region because of serious hypoplasia (microgenia) is performed by chin augmentation. Chin augmentation is most frequently performed via implant or osseous genioplasty in the literature. Both 2 techniques have their own advantages and disadvantages. In the literature, various studies comparing these 2 techniques and their long-term results are present, but in some severe microgenia cases, these techniques can be insufficient only for augmentation. In such cases, combined use of implant and osseous genioplasty techniques can come up and data and experiences regarding such combined uses are limited in the literature. In our study, we aim to report our experiences and long-term results regarding 3 cases to whom chin augmentation combined with implant and osseous method is applied because of serious chin hypoplasia (microgenia). Three patients to whom chin augmentation combined with osseous and implant genioplasty was applied because of severe microgenia between 2011 and 2016 are included in our study. Before the chin restoration, orthognathic surgery or maxillomandibular distraction applications owing to existing obstructive sleep apnea, malocclusion, or facial asymmetry, are performed in the patients. In preoperative period, chin augmentation amount required is planned for all the patients via cephalometric analysis and the operations of all the patients are performed under general anesthesia via intraoral access. Among 3 patients, 2 were male and 1 was female and their mean age was 27.3 years (22-33). In all the patients, primarily horizontal subapical sliding osteotomy was performed and advancement was performed. After osteotomy, mean 8-mm osseous advancement was obtained and Medpor implant was placed in the chin at the same session for additional

  20. Impression of multiple implants using photogrammetry: description of technique and case presentation.

    Science.gov (United States)

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz; Peñarrocha, María

    2014-07-01

    To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions - angles and distances - of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient's mouth using the Sheffield test and the screw resistance test. Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient.

  1. Cutaneous and systemic hypersensitivity reactions to metallic implants

    DEFF Research Database (Denmark)

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    ) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions......Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous......, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure...

  2. Gold implant therapy of locomotory disorders in dogs - Case studies

    Directory of Open Access Journals (Sweden)

    Emilia Abrudean

    2016-06-01

    Full Text Available The case study was conducted between October and January 2015, on 7 dogs of different breeds and ages, which at clinical examination showed varying degrees of lameness. The dogs behavior and state of consciousness, their attitude in standing, decubitus and at walk and the presence of involuntary movements was assessed through inspection. Palpation was used to feel muscular tonus, local temperature and sensibility. Postural reactions were highlighted by carrying out forced positions of each limb, thus highlighting the proprioceptive sensitivity. By testing the spinal reflexes the reactions of the forelimbs and hind limbs were evaluated, seeking the state of normality, or the absence, diminution or exacerbation of these reflexes. Also, diagnostic imaging was performed consisting of simple radiographs, were performed for the cases that entered the clinic. In the case of digital X-rays, X-rays are passing through the subject being examined are filtered, then touch a plate of sensors able to convert signals generated into digital information with an image appear on the computer screen. Interpretation of results was done by assessing the degree of dysplasia, and the Norberg-Olson angle and stage. This study used digital radiography as imaging technique; the device was Rx-M EVO Fujifilm. On the basis of diagnostic imaging and computerized image, diagnosis was established for each case. The treatment protocol with gold implant was the same for all seven cases; the adopted procedure was the "Wiener" procedure, described by Kasper and Zohmann. The procedure began with establishing a set of points associated with the treatment of hip dysplasia, spondylosis, arthritis, and osteochondritis. For the therapeutic protocol to be performed correctly took the dogs were sedated. This was done with medetomidine hydrochloride (Dorbene vet, Pfizer, concentration 1 mg⁄ml, administered in a 0,1mg⁄kg body weight dose. The results were visible after a month from the

  3. Scala vestibuli insertion in cochlear implantation: a valuable alternative for cases with obstructed scala tympani.

    Science.gov (United States)

    Kiefer, J; Weber, A; Pfennigdorff, T; von Ilberg, C

    2000-01-01

    Insertion of a sufficient number of electrodes is important for a successful use of cochlear implants. We investigated the results of scala vestibuli insertion for cochlear implantation in cases of obstructed scala tympani. In a series of 200 cochlear implantations, scala vestibuli insertion was successfully performed in 4 cases with obstruction of the scala tympani. Etiologies included a temporal bone fracture, severe otosclerosis and malformations of the cochlea. The maximum insertion depth obtained via the scala vestibuli was 30 mm. Postoperative results were comparable to patients in whom conventional scala tympani insertion was performed. No adverse effects related to the site of insertion were observed. Scala vestibuli insertion offers a valuable alternative in cases of obstructed scala tympani that can be employed for a variety of etiologies. Copyright 2000 S. Karger AG, Basel

  4. Distant Migration of Multiple Siliconomas in Lower Extremities following Breast Implant Rupture: Case Report

    OpenAIRE

    Oh, Joo Hyun; Song, Seung Yong; Lew, Dae Hyun; Lee, Dong Won

    2016-01-01

    Summary: Siliconoma from ruptured breast implants has been reported in multiple body sites, including but not limited to the breast parenchyma, axillary lymph nodes, upper arm, and even lower leg. In this regard, we report a rare case of distant silicone migration to the lower extremities after traumatic breast implant rupture. A 55-year-old Asian woman who received bilateral augmentation mammoplasty 20 years ago presented with ruptured breast implants from a car accident 2 years earlier. Mag...

  5. Quantitative damage depth profiles in arsenic implanted HgCdTe

    Energy Technology Data Exchange (ETDEWEB)

    Lobre, C., E-mail: clement.lobre@cea.fr [CEA-Leti, MINATEC, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France); Jalabert, D. [CEA-INAC/UJF-Grenoble 1 UMR-E, MINATEC, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France); Vickridge, I.; Briand, E.; Benzeggouta, D. [Institut des NanoSciences de Paris, UMR 7588 du CNRS, Universite de Pierre et Marie Curie, Paris (France); Mollard, L. [CEA-Leti, MINATEC, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France); Jouneau, P.H. [CEA-INAC/UJF-Grenoble 1 UMR-E, MINATEC, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France); Ballet, P. [CEA-Leti, MINATEC, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France)

    2013-10-15

    Rutherford backscattering experiments under channeling conditions (RBS-c) have been carried out on Hg{sub 0.77}Cd{sub 0.23}Te (MCT) layers implanted with arsenic. Accurate damage profiles have been extracted through a simple formalism for implanted and annealed layers. Quantitative damage profiles are correlated with structural defects observed by bright-field scanning transmission electron microscopy (BF-STEM) and chemical composition measured by secondary ion mass spectrometry (SIMS). Evolution of damage for increasing ion implantation fluence has been investigated by these three complementary techniques. Evidence is found of irradiation induced annealing during implantation. A fast damage recovery has been observed for post-implantation thermal anneals. In the case of an implanted layer annealed during 1 h, the damage profile, associated with arsenic concentration measurements, indicates the presence of complexes involving arsenic.

  6. Quantitative damage depth profiles in arsenic implanted HgCdTe

    International Nuclear Information System (INIS)

    Lobre, C.; Jalabert, D.; Vickridge, I.; Briand, E.; Benzeggouta, D.; Mollard, L.; Jouneau, P.H.; Ballet, P.

    2013-01-01

    Rutherford backscattering experiments under channeling conditions (RBS-c) have been carried out on Hg 0.77 Cd 0.23 Te (MCT) layers implanted with arsenic. Accurate damage profiles have been extracted through a simple formalism for implanted and annealed layers. Quantitative damage profiles are correlated with structural defects observed by bright-field scanning transmission electron microscopy (BF-STEM) and chemical composition measured by secondary ion mass spectrometry (SIMS). Evolution of damage for increasing ion implantation fluence has been investigated by these three complementary techniques. Evidence is found of irradiation induced annealing during implantation. A fast damage recovery has been observed for post-implantation thermal anneals. In the case of an implanted layer annealed during 1 h, the damage profile, associated with arsenic concentration measurements, indicates the presence of complexes involving arsenic

  7. Management of complications of cosmetic iris implants in a phakic eye: a case report and literature review.

    Science.gov (United States)

    Bore, Millicent; Choudhari, Nikhil; Chaurasia, Sunita

    2018-03-21

    To report the intricacies of managing complications that arose out of cosmetic iris implants (BrightOcular) placement. Interventional case report. A thirty-year-old gentleman presented with complaint of progressive loss of vision after having cosmetic iris implant surgery to change his eye colour. He then developed raised intraocular pressures and had a right eye trabeculectomy conducted with the implants in situ. Subsequently, he had implant removal surgery because of persistent implant-associated complications. The vision was impaired due to progressive corneal oedema and glaucoma. Various considerations were taken while planning for surgical intervention because of the extensive structural damage to the anterior segment of the eye. This case report highlights that cosmetic iris implants are dangerous intraocular devices and management of the associated complications is also challenging. As these devices cause irreversible structural and functional damage, their use should be discouraged in normal eyes.

  8. Adult patient decision-making regarding implantation of complex cardiac devices: a scoping review.

    Science.gov (United States)

    Malecki-Ketchell, Alison; Marshall, Paul; Maclean, Joan

    2017-10-01

    Complex cardiac rhythm management device (CRMD) therapy provides an important treatment option for people at risk of sudden cardiac death. Despite the survival benefit, device implantation is associated with significant physical and psychosocial concerns presenting considerable challenges for the decision-making process surrounding CRMD implantation for patients and physicians. The purpose of this scoping review was to explore what is known about how adult (>16 years) patients make decisions regarding implantation of CRMD therapy. Published, peer reviewed, English language studies from 2000 to 2016 were identified in a search across eight healthcare databases. Eligible studies were concerned with patient decision-making for first time device implantation. Quality assessment was completed using the mixed methods appraisal tool for all studies meeting the inclusion criteria. The findings of eight qualitative and seven quantitative studies, including patients who accepted or declined primary or secondary sudden cardiac death prevention devices, were clustered into two themes: knowledge acquisition and the process of decision-making, exposing similarities and distinctions with the treatment decision-making literature. The review revealed some insight in to the way patients approach decision-making but also exposed a lack of clarity and research activity specific to CRMD patients. Further research is recommended to support the development and application of targeted decision support mechanisms.

  9. Displacement of a dental implant into the maxillary sinus after internal sinus floor elevation: report of a case and review of literature.

    Science.gov (United States)

    Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng

    2015-01-01

    Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.

  10. A new method to solve anophthalmic contracted socket in embedding orbital implant in 114 cases

    Directory of Open Access Journals (Sweden)

    Ming Cheng

    2017-10-01

    Full Text Available AIM: To perform a new method for orbital implant and contracted socket through one time and its results.METHODS: Totally 114 patients 114 eyes, from January 2008 to June 2014, with contracted socket participated in this study. We incised the bulbar conjunctiva horizontally and excised scar tissue, then implanted the hydroxyapatite in the four extraocular muscles and tightly sutured the Tenon' capsule. After that, we put the superior and inferior conjunctival petals backwards and sutured them to the Tenon's capsule. All the patients were divided into four groups according to the vertical diameter length of the conjunctival defect area: Group Ⅰ: ≤5mm; Group Ⅱ: 6-10mm; Group Ⅲ: 11-15mm; and Group Ⅳ: ≥16mm. These patients were followed up for 6mo to 3y to observe the conjunctival sac shaping and growth of conjunctiva.RESULTS: There were 64 cases in Group Ⅰ, 31 cases in Group Ⅱ, 16 cases in Group Ⅲ and 3 cases in Group Ⅳ. All patients' conjunctival defect was covered by new conjunctiva and scar tissue 4 to 6wk after surgeries. Ten cases had contracted socket; 2 cases had orbital implant exposure, requiring reoperation. Of the 114 cases, 8 had contracted socket and could use a smaller conformer, 106 could use a normal size conformer.CONCLUSION: When the conjunctival defect was ≤15mm, this new method can address the orbital implant and contracted socket at the same time. While it was ≥16mm, flap transplantation is necessary.

  11. Implant-supported rehabilitation after treatment of atrophic mandibular fractures: report of two cases.

    Science.gov (United States)

    Oliveira, Leandro Benetti de; Gabrielli, Marisa Aparecida Cabrini; Gabrielli, Mario Francisco Real; Pereira-Filho, Valfrido Antonio Pereira

    2015-12-01

    The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (fractures. Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.

  12. A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.

    Science.gov (United States)

    Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti

    2014-02-01

    Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.

  13. Vitreous occlusion of tube implant in a phakic patient with traumatic glaucoma

    Directory of Open Access Journals (Sweden)

    Suneeta Dubey

    2014-01-01

    Full Text Available Tube implants or glaucoma drainage devices have become an important method of intraocular pressure reduction when treating complex cases of traumatic glaucoma. However, it is not uncommon to have complications associated with tube implants. The optimal treatment of patients who have undergone glaucoma implant surgery complicated by vitreous incarceration is uncertain. If vitreous is present or is able to prolapse into anterior chamber, as in aphakic or pseudophakic patient without an intact posterior capsule, a concurrent anterior vitrectomy is usually performed. In such cases, pars plana vitrectomy has been found to be more effective in several studies. However, there are no set guidelines for management of such a case in a phakic eye and the management can be more challenging especially when there is no obvious deficiency in posterior capsule, zonular dialysis, or loose vitreous gel in the anterior chamber prior to or during tube implantation. We describe a case of 14-year-old phakic patient with traumatic glaucoma without vitreous gel in anterior chamber whose tube implant became occluded by vitreous resulting in increased intra ocular pressure. This is the first documented report of vitreous incarceration in a phakic patient and its successful management.

  14. A computationally efficient simulator for three-dimensional Monte Carlo simulation of ion implantation into complex structures

    International Nuclear Information System (INIS)

    Li Di; Wang Geng; Chen Yang; Li Lin; Shrivastav, Gaurav; Oak, Stimit; Tasch, Al; Banerjee, Sanjay; Obradovic, Borna

    2001-01-01

    A physically-based three-dimensional Monte Carlo simulator has been developed within UT-MARLOWE, which is capable of simulating ion implantation into multi-material systems and arbitrary topography. Introducing the third dimension can result in a severe CPU time penalty. In order to minimize this penalty, a three-dimensional trajectory replication algorithm has been developed, implemented and verified. More than two orders of magnitude savings of CPU time have been observed. An unbalanced Octree structure was used to decompose three-dimensional structures. It effectively simplifies the structure, offers a good balance between modeling accuracy and computational efficiency, and allows arbitrary precision of mapping the Octree onto desired structure. Using the well-established and validated physical models in UT-MARLOWE 5.0, this simulator has been extensively verified by comparing the integrated one-dimensional simulation results with secondary ion mass spectroscopy (SIMS). Two options, the typical case and the worst scenario, have been selected to simulate ion implantation into poly-silicon under various scenarios using this simulator: implantation into a random, amorphous network, and implantation into the worst-case channeling condition, into (1 1 0) orientated wafers

  15. Short-term retrospective case series of implant-assisted removable partial dentures with locator abutments.

    Science.gov (United States)

    Ortiz-Puigpelat, Octavi; Gargallo-Albiol, Jordi; Hernández-Alfaro, Federico; Cabratosa-Termes, Josep

    2014-01-01

    The purpose of this retrospective case series was to report on the clinical performance of implant-assisted removable partial dentures (IARPDs) with Locator abutments in different partial edentulism situations, with a mean follow-up period of 28.6 months. Twelve consecutive patients were treated with IARPDs. A total of 24 implants were placed in the edentulous area. Minimum follow-up period was 12 months. Overall patient satisfaction, health of peri-implant tissues, survival of implants and abutments, and prosthetic complications were reported. Overall implant survival was 91.6%; two implants failed. No major complications were reported-only one IARPD metal framework broke. No Locator abutment loosening was reported. Within the limitations of this retrospective study, treatment with IARPDs can improve the patient's function, phonetics, and esthetics without the need for extensive bone regeneration surgeries and prosthodontic rehabilitations. However, well-designed prospective clinical studies on IARPDs are needed to support their long-term use.

  16. Use of transitional implants for immediate loading in mandibular complete dentures- A case report

    Directory of Open Access Journals (Sweden)

    Seema Bhoosreddy

    2009-01-01

    Full Text Available After the placement of implants in areas in which several teeth have been lost, both the clinician and the patient face many difficulties, particularly during healing. If no prosthesis is provided, the patient′s quality of life suffers. If a removable prosthesis is provided for optimum mastication and speech, many complicated adjustments of the denture may become necessary during healing, and the possibility of osseointegration failure increases. It has been reported that for implants to become osseointegrated, they must heal in the absence of functional loads for 4 to 6 months. To address the need for undisturbed healing and patient demand for uninterrupted immediate function and esthetics, the transitional implant system has been developed. This case report describes the use of transitional implants to support a removable mandibular overdenture. The transitional implant system is a sound and economical method of immediate patient restoration that allows for the protected healing of submerged implants.

  17. Gingival recontouring by provisional implant restoration for optimal emergence profile: report of two cases.

    Science.gov (United States)

    Son, Mee-Kyoung; Jang, Hyun-Seon

    2011-12-01

    The emergence profile concept of an implant restoration is one of the most important factors for the esthetics and health of peri-implant soft tissue. This paper reports on two cases of gingival recontouring by the fabrication of a provisional implant restoration to produce an optimal emergence profile of a definitive implant restoration. After the second surgery, a preliminary impression was taken to make a soft tissue working cast. A provisional crown was fabricated on the model. The soft tissue around the implant fixture on the model was trimmed with a laboratory scalpel to produce the scalloped gingival form. Light curing composite resin was added to fill the space between the provisional crown base and trimmed gingiva. After 4 to 6 weeks, the final impression was taken to make a definitive implant restoration, where the soft tissue and tooth form were in harmony with the adjacent tooth. At the first insertion of the provisional restoration, gum bleaching revealed gingival pressure. Four to six weeks after placing the provisional restoration, the gum reformed with harmony between the peri-implant gingiva and adjacent dentition. Gingival recontouring with a provisional implant restoration is a non-surgical and non-procedure-sensitive method. The implant restoration with the optimal emergence profile is expected to provide superior esthetic and functional results.

  18. Immediate provisional restoration of an implant placed in a fresh primary maxillary canine extraction socket: a case report.

    Science.gov (United States)

    Turkyilmaz, Ilser; Shapiro, Vladimir

    2011-01-01

    This study describes a clinical case in which a primary maxillary canine with both mobility and root resorption was replaced with an immediately restored dental implant placed into the fresh extraction socket. The implant achieved high primary stability, as determined by resonance frequency analysis, and it was immediately restored with a provisional acrylic resin crown with no centric occlusion. An all-ceramic permanent crown replaced the provisonal crown four months after implant surgery. The implant was stable and no periapical radiolucencies, bleeding on probing, or pathologic probing depth were recorded after one year. The peri-implant soft tissue level appeared stable, and the interdental papillae were preserved, contributing to an optimum final esthetic result. This case supports the use of single implants for the replacement of extracted primary teeth, especially in areas where esthetics is a high priority. The immediate provisional crown maintained soft tissue contours and papillary height.

  19. Effect of the order of He{sup +} and H{sup +} ion co-implantation on damage generation and thermal evolution of complexes, platelets, and blisters in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Daghbouj, N. [CEMES-CNRS and Université de Toulouse, 29 rue J. Marvig, 31055 Toulouse (France); Faculté des Sciences de Monastir, Université de Monastir, Monastir (Tunisia); Cherkashin, N., E-mail: nikolay.cherkashin@cemes.fr; Darras, F.-X.; Paillard, V.; Claverie, A. [CEMES-CNRS and Université de Toulouse, 29 rue J. Marvig, 31055 Toulouse (France); Fnaiech, M. [Faculté des Sciences de Monastir, Université de Monastir, Monastir (Tunisia)

    2016-04-07

    Hydrogen and helium co-implantation is nowadays used to efficiently transfer thin Si layers and fabricate silicon on insulator wafers for the microelectronic industry. The synergy between the two implants which is reflected through the dramatic reduction of the total fluence needed to fracture silicon has been reported to be strongly influenced by the implantation order. Contradictory conclusions on the mechanisms involved in the formation and thermal evolution of defects and complexes have been drawn. In this work, we have experimentally studied in detail the characteristics of Si samples co-implanted with He and H, comparing the defects which are formed following each implantation and after annealing. We show that the second implant always ballistically destroys the stable defects and complexes formed after the first implant and that the redistribution of these point defects among new complexes drives the final difference observed in the samples after annealing. When H is implanted first, He precipitates in the form of nano-bubbles and agglomerates within H-related platelets and nano-cracks. When He is implanted first, the whole He fluence is ultimately used to pressurize H-related platelets which quickly evolve into micro-cracks and surface blisters. We provide detailed scenarios describing the atomic mechanisms involved during and after co-implantation and annealing which well-explain our results and the reasons for the apparent contradictions reported at the state of the art.

  20. Maintenance of class III trifurcated molars versus implant placement in regenerated extraction sockets: long-term results of 2 cases.

    Science.gov (United States)

    Zafiropoulos, Gregory-George K; di Prisco, Manuela Occipite; Deli, Giorgio; Hoffmann, Oliver

    2011-03-01

    Studies to date have reached differing conclusions regarding the long-term prognosis of teeth with class III furcation involvement. Replacement of such teeth with implants could be an alternative. This report compares the treatment outcomes of 2 cases with similar disease progression: 1 treated by implant therapy and 1 maintained with nonsurgical periodontal treatment. Two patients with advanced chronic periodontitis and class III furcation involvement of all molars were treated. Case 1 received a conservative periodontal and antibiotic treatment, followed by 15 years of maintenance. In case 2, the molars were extracted and replaced with implants, and the implants were observed for 7 years. Clinical attachment level (CAL), probing attachment level (PAL), bleeding on probing, plaque index, and periodontal pathogens were recorded. Despite good compliance of case 1, periodontal pathogens were not eliminated and tissue destruction was not halted. The PAL outcomes of case 2 improved over time; mean PAL loss reached 0.35 mm/y in the first 3 years and then decreased to 0.01 mm/y. While CAL outcomes did not change in case 2, case 1 showed increased CAL loss after 8 years. Based on the limited findings of this case report, extraction of molars with class III furcation involvement and subsequent implant placement may render a better predictability of treatment outcomes than nonsurgical periodontal therapy in the cases of infection with periodontal pathogens.

  1. The use of bone block allografts in sinus augmentation, followed by delayed implant placement: A case series

    Directory of Open Access Journals (Sweden)

    Eurico D Aloja

    2013-01-01

    Full Text Available Purpose: This article reports the clinical outcomes observed in a large number of patients receiving block bone allograft used for sinus augmentation and delayed implant placement. Patients and Methods: In total, 28 patients (13 males with a mean age of 49.8 ± 10.1 years (range: 33-67 years were included in this case series. All selected patients suffered from severe alveolar ridge atrophy in the posterior maxilla and required bone augmentation procedures, followed by implant placement after 6 months. All patients were followed for 18 months after the grafting, with scheduled monthly visits and/or more frequent visits if required. The survival rates for both the bone blocks and placed implants were then evaluated. Results: A total of 42 blocks and 90 implants were placed. Only one bone graft and 5 implants failed; the survival rate was 97.2% and 95.5% for the bone grafts and implants, respectively. The graft failed due to the onset of post-surgical infectious sinusitis, while in some patients′ implants showed absence of osteointegration at the end of the healing phase. Of note, all failed implants were observed in heavy smokers; in all other patients, blocks and implants were successful. Conclusions: This preliminary case series suggests that the grafting of bone allograft followed by delayed implant placement may be a promising strategy for sinus augmentation. More extended and larger follow-up studies are needed to confirm this preliminary data.

  2. Miragel implant, apropos of 3 cases

    OpenAIRE

    Rodríguez Rodríguez, Beatriz; García Ferrer, Laine; Cheong Quiala, Mayelin; Gallar Gutiérrez, Yolescy; Pozo Correa, Susel

    2013-01-01

    Se exponen las consecuencias a largo plazo del uso del implante de miragel como tratamiento del desprendimiento de retina. Se presentan las características durante la cirugía y el postoperatorio de la explantación de este tipo de implante en 3 pacientes que acudieron a la consulta de Retina del Hospital Oftalmológico «Amistad Argelia Cuba» en Djelfa, Republica Popular y Democrática de Argelia, con el diagnóstico de cirugía convencional de retina con implante de miragel realizado en Francia en...

  3. Implant Gigi One-Piece vs Two-Pieces dalam Praktek Sehari-Hari

    Directory of Open Access Journals (Sweden)

    Dian Lestari Kurnia

    2014-12-01

    prosedur bedah dan prosedur prostetik lebih sederhana. Desain ini juga meniadakan celah mikro pada perbatasan implant dan abutment. Desain implant gigi one-piece memiliki keterbatasan pada pilihan prosedur prostetik apabila dibandingkan dengan desain implant gigi two-pieces.   One-Piece Versus Two-pieces Tooth Implant In Daily Practice. Implant had been a gold standard to replace missing tooth. However, implant marketed today was considered complex, and needs a second surgery. Complications may occur such as screw loosening or fracture and the presence of micro gap at implant-abutment-junction that is found causing fixture failure. The one-piece-implant design may offer some advantages. Purpose: this paper was aimed to discuss the pros and cons of one-piece-implants and two-piece-implants. Case 1 A 43-year-old woman came to place an implant on #16. The available bone height was 5 mm. A trans alveolar sinus lift procedure was performed with 0,5 cc allograft. A 12 mm one-piece-implant was inserted. Case 2 A 24-year-old woman came to place an implant on #46. The available bone height was 12 mm and a 10 mm two-piece-implant was inserted. Discussion: One-piece-implant offers some advantage. It needs no second surgery, easier placement protocol, and more natural prosthetic procedures. The design is preventing the failure in implant-abutment-junction failure. The absence of micro gap in one-piece-implant seems superior in preventing crestal bone resorption. However, the prosthetic option was limited in one-piece-implant. Two-piece-implant offers more choices in prosthetic abutment. Conclusion: One-piece-implant was easier and provide simple protocol with limited choice on prosthetic.

  4. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  5. Incisive canal deflation for correct implant placement: case report.

    Science.gov (United States)

    Spin-Neto, Rubens; Bedran, Telma Blanca Lombardo; de Paula, Wagner Nunes; de Freitas, Rubens Moreno; de Oliveira Ramalho, Lizeti Toledo; Marcantonio, Elcio

    2009-12-01

    This article is a case report of a patient in whom the prosthetic planning indicated the necessity of an incisive canal deflation for the correct installation of an implant that is to be osseointegrated. In the reopening phase after the bone graft installation, the incisive canal deflation (biopsy of its content) was done and titanium implants were installed with one of them invading the anatomical space occupied previously by the incisive canal. The biopsy analysis showed fragments of the incisive artery and nerve, which are responsible for the anterior upper-tooth pulp, the periodontium vascularization and the innervation. From the anastomosis present along with other structures allied with the absence of teeth in the region, there was no detriment to the patient caused by the deflation. Incisive canal deflation is a viable technique in implantology. It can permit ideal prosthetic planning with no detriment to the patient.

  6. Implant-retained dentures for full-arch rehabilitation: a case report comparing fixed and removable restorations.

    Science.gov (United States)

    Zafiropoulos, Gregory-George; Hoffman, Oliver

    2011-01-01

    Dental implants as abutments for full-arch restorations are a well-documented treatment modality. This report presents a case in which the patient was treated initially with fixed restorations supported by either implants or natural teeth and subsequently treated with a removable implant/telescopic crown-supported overdenture. Advantages and disadvantages of each approach are described and discussed. While the fixed restoration resulted in a functionally satisfactory treatment outcome, the patient was displeased with the esthetic appearance. The main concern was the unnaturally long tooth shape necessary to compensate for the insufficient alveolar ridge height. Replacement of the existing restoration with an implant-supported removable overdenture led to a functionally and esthetically acceptable result. When deciding whether to use a fixed or removable implant-supported full-arch restoration, a multitude of factors must be considered. Due to the possible need for additional surgical steps to enhance the esthetic appearance surrounding fixed restorations, removable implant-supported partial dentures often are the better choice.

  7. Complex radiological diagnosis of a breast cancer at women after augmentation mammоplasty of silicone gel implants

    Directory of Open Access Journals (Sweden)

    T. A. Shumakova

    2014-01-01

    Full Text Available One of leading problems of mammology is early diagnostics of a breast cancer. The work purpose studying of opportunities of a complex of radiological research techniques in diagnostics of a breast cancer at women after augmentation mammoplasty silicone gel implants. By results of сomplex kliniko-radiological examination of 630 women aged from 18 till 72 years (middle age made 35 ± 0.43 years with 1260 implants the breast cancer was revealed at 7 (1.1 % patients. The invasive pro-current cancer with local widespread type of body height of tumoral knot is histologically diagnosed. Sensitivity and specificity of methods of radiodiagnosis in identification of a cancer of mammary glands at women after endoprosthesis replacement made mammography – 28.6 % and 66.1 %, ultrasonography – 71.4 % and 85.7 %, magnetic resonance imaging – 85.7 % and 98.2 %, respectively. Thus, complex application of radiology research techniques raises level of diagnostics of breast cancer at patients after augmentation mammoplasty silicone gel implants that allows to choose an adequate method of treatment.

  8. Group Distal Movement of Teeth using Micro-Screw-Implant Anchorage-A Case Report.

    Science.gov (United States)

    Kalarickal, Biju

    2014-05-01

    This case report describes a case of orthodontic tooth movement of a 29-year-old female patient utilizing maxillary posterior edentulous area. Micro-implants were placed at buccal edentulous spaces and inter-radicular space for retraction of entire maxillary dentition. An overjet reduction of 8mm and good posterior occlusion were achieved.

  9. [Correction of congenital malformations by custom-made silicone implants: Contribution of computer-aided design. Experience of 611 cases].

    Science.gov (United States)

    Chavoin, J P; Chaput, B; Garrido, I; Moreno, B; Dahan, M; Grolleau, J L

    2016-10-01

    Modern techniques of computer-aided design and tridimensional prototyping for manufacturing silicone elastomer custom implants are growing. They have widely modified the surgical indications in our unit. By presenting their experience of 611 cases managed between 1993 and 2016, the authors describe the method of conception from CT-scans, the virtual image of the body and the manufacture of the custom-made implant perfectly adapted to the anatomy of each one. The operative techniques are described for the three main indications: the funnel chest or pectus excavatum (474 cases) according to a modified CHIN classification is corrected simply and very satisfactorily. This approach may render thoracic surgery techniques obsolete. Indeed, these operations remain risky and of doubtful functional utility; Poland syndrome (116 cases), where the use of a custom-made implant for compensation of muscle volume is frequently used, but can be improved by a transfer of adipose tissue or a classic breast implant; the leg atrophies (21 cases) receive custom elastomer implants introduced in a sub-fascial plane. The results are excellent for pectus excavatum but more difficult to optimize for the other two indications, requiring sometimes complementary techniques. Complications are rare and often benign, implants endure for life. Quality of life, psychological comfort and self-esteem have been improved with low morbidity and without having undergone a painful surgical experience. Reconstructive procedures of congenital malformations by custom-made silicone implants open a new field of activity for our surgical specialty with vast opportunities. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  11. 3D Printed, Customized Cranial Implant for Surgical Planning

    Science.gov (United States)

    Bogu, Venkata Phanindra; Ravi Kumar, Yennam; Asit Kumar, Khanra

    2018-06-01

    The main objective of the present work is to model cranial implant and printed in FDM machine (printer model used: mojo). Actually this is peculiar case and the skull has been damaged in frontal, parietal and temporal regions and a small portion of frontal region damaged away from saggital plane, complexity is to fill this frontal region with proper curvature. The Patient CT-data (Number of slices was 381 and thickness of each slice is 0.488 mm) was processed in mimics14.1 software, mimics file was sent to 3-matic software and calculated thickness of skull at different sections where cranial implant is needed then corrected the edges of cranial implant to overcome CSF (cerebrospinal fluid) leakage and proper fitting. Finally the implant average thickness is decided as 2.5 mm and printed in FDM machine with ABS plastic.

  12. Case presentation of florid cemento-osseous dysplasia with concomitant cemento-ossifying fibroma discovered during implant explantation.

    Science.gov (United States)

    Gerlach, Robert C; Dixon, Douglas R; Goksel, Tamer; Castle, James T; Henry, Walter A

    2013-03-01

    A 39-year-old African American woman presented for treatment of a symptomatic mandibular right first molar with a large, periapical radiolucency. After initial attempts at endodontic therapy, this tooth was ultimately extracted owing to unabated symptoms. The extraction site underwent ridge preservation grafting, implant placement, and restoration. After 26 months of implant function, the patient returned with clinical symptoms of pain, buccal swelling, and the sensation of a "loose" implant. This case report details a diagnosis of 2 distinct disease entities associated with the implant site, a cemento-ossifying fibroma and florid cemento-osseous dysplasia of the mandible. This diagnosis was determined from clinical, surgical, radiographic, and histopathologic evidence after biopsy and removal of the previously osseointegrated implant following postinsertion failure by fibrous encapsulation. Before implant therapy, it is essential to conduct a thorough radiographic evaluation of any dental arch with suspected bony lesions to prevent implant failure. Published by Mosby, Inc.

  13. A glass fiber-reinforced composite - bioactive glass cranioplasty implant: A case study of an early development stage implant removed due to a late infection.

    Science.gov (United States)

    Posti, Jussi P; Piitulainen, Jaakko M; Hupa, Leena; Fagerlund, Susanne; Frantzén, Janek; Aitasalo, Kalle M J; Vuorinen, Ville; Serlo, Willy; Syrjänen, Stina; Vallittu, Pekka K

    2015-03-01

    This case study describes the properties of an early development stage bioactive glass containing fiber-reinforced composite calvarial implant with histology that has been in function for two years and three months. The patient is a 33-year old woman with a history of substance abuse, who sustained a severe traumatic brain injury later unsuccessfully treated with an autologous bone flap and a custom-made porous polyethylene implant. She was thereafter treated with developmental stage glass fiber-reinforced composite - bioactive glass implant. After two years and three months, the implant was removed due to an implant site infection. The implant was analyzed histologically, mechanically, and in terms of chemistry and dissolution of bioactive glass. Mechanical integrity of the load bearing fiber-reinforced composite part of the implant was not affected by the in vivo period. Bioactive glass particles demonstrated surface layers of hydroxyapatite like mineral and dissolution, and related increase of pH was considerably less after two and three months period than that for fresh bioactive glass. There was a difference in the histology of the tissues inside the implant areas near to the margin of the implant that absorbed blood during implant installation surgery, showed fibrous tissue with blood vessels, osteoblasts, collagenous fibers with osteoid formation, and tiny clusters of more mature hard tissue. In the center of the implant, where there was less absorbed blood, only fibrous tissue was observed. This finding is in line with the combined positron emission tomography - computed tomography examination with (18F)-fluoride marker, which demonstrated activity of the mineralizing bone by osteoblasts especially at the area near to the margin of the implant 10 months after implantation. Based on these promising reactions found in the bioactive glass containing fiber-reinforced composite implant that has been implanted for two years and three months, calvarial

  14. Cochlear Implantation in Patients with Keratitis-Ichthyosis-Deafness Syndrome: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Birgul Gumus

    2017-01-01

    Full Text Available Background. Keratitis-ichthyosis-deafness (KID syndrome is a syndrome which presents with hearing loss and visual and keratinization disorders. In such patients, hearing aids cannot be effectively used in the rehabilitation of hearing loss because of the frequent blockage of the external ear canal with epithelial debris and due to dry and tense skin of the external ear canal. Moreover, severe or profound hearing loss also limits the benefits gained from the conventional hearing aids. On the other hand, cochlear implantation is a method that has been used in limited cases in the literature. Case Report. This study presents the results of cochlear implantation applied in our clinic to two children who had been diagnosed with KID. Audiological assessments before and after the cochlear implant operation were performed using pure-tone audiometry, immittance audiometry, and auditory brainstem response (ABR, and the postoperative follow-up was conducted using pure-tone audiometry. Conclusion. Skin problems, visual disturbances, and other additional problems complicate the short-term and long-term rehabilitation after implantation in individuals with KID syndrome. Close monitoring should be exercised due to possible skin complications that may develop during the postoperative period. The families and rehabilitation teams should be warned about the possible visual disturbances and skin complications.

  15. Nipple-sparing mastectomy with immediate implant reconstruction: cosmetic outcomes and technical refinements.

    Science.gov (United States)

    Salgarello, Marzia; Visconti, Giuseppe; Barone-Adesi, Liliana

    2010-11-01

    Nipple-sparing mastectomy is gaining widespread popularity, as it could allow improved aesthetic outcome without increasing oncologic risk. To investigate the reconstructive issues experienced with immediate implant reconstruction, the authors reviewed the cosmetic outcomes of their series. The authors retrospectively analyzed the data on 33 cases of nipple-sparing mastectomy for both cancer and prophylaxis with immediate implant reconstruction using the submusculo-subfascial pocket. Cosmetic evaluation methods were clinical and photography-based assessments and a patient-satisfaction survey. The average follow-up period was 26.8 months. No nipple-areola complex cancer involvement was registered. The reconstructive outcomes ranged from good to excellent in 83 percent of the cases. Patients' satisfaction was high to very high, except in one patient who experienced total nipple-areola complex loss (one breast, 2.4 percent). Overall, early minor complications were registered in four breasts (9.5 percent) and late minor complications in five cases (12 percent). The authors' series suggest that nipple-sparing mastectomy is an option for carefully selected and screened patients. Larger studies with longer follow-up are needed, however. On the whole, the immediate one-stage implant reconstruction with hyperprojected anatomical gel implants represents a valid option. The skin incision algorithm proposed, which is based on the breast size, shape, and previous scars, might aid in the decision-making process to achieve satisfying results using this procedure. The radial approaches represent a good compromise between the oncologic and reconstructive procedures.

  16. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  17. Various Techniques to Increase Keratinized Tissue for Implant Supported Overdentures: Retrospective Case Series

    Directory of Open Access Journals (Sweden)

    Ahmed Elkhaweldi

    2015-01-01

    Full Text Available Purpose. The purpose of this retrospective case series is to describe and compare different surgical techniques that can be utilized to augment the keratinized soft tissue around implant-supported overdentures. Materials and Methods. The data set was extracted as deidentified information from the routine treatment of patients at the Ashman Department of Periodontology and Implant Dentistry at New York University College of Dentistry. Eight edentulous patients were selected to be included in this study. Patients were treated for lack of keratinized tissue prior to implant placement, during the second stage surgery, and after delivery of the final prosthesis. Results. All 8 patients in this study were wearing a complete maxillary and/or mandibular denture for at least a year before the time of the surgery. One of the following surgical techniques was utilized to increase the amount of keratinized tissue: apically positioned flap (APF, pedicle graft (PG, connective tissue graft (CTG, or free gingival graft (FGG. Conclusions. The amount of keratinized tissue should be taken into consideration when planning for implant-supported overdentures. The apical repositioning flap is an effective approach to increase the width of keratinized tissue prior to the implant placement.

  18. Case report: traumatic displacement of a cochlear implant magnet.

    Science.gov (United States)

    Keereweer, Stijn; Van der Schroeff, Marc P; Pullens, Bas

    2014-04-01

    To date, over 200 000 cochlear implants (CIs) have been implanted worldwide and the incidence is still increasing. We present a case of traumatic displacement of CI magnet to raise awareness about this complication and to highlight the need for vigilance during surgery as well as for proper counseling. The clinical presentation of a 1.5-year-old boy with a traumatic displacement of a CI magnet was presented and the literature was reviewed for this rare complication. After minor head injury, the sound processor could no longer connect to the CI. X-ray imaging demonstrated displacement of the CI magnet. During revision surgery, the magnet was replaced by a new magnet in the silicon holding cap. Intraoperative impedance measurements were normal and the CI was successfully activated 4 weeks postoperatively. Clinicians and patients should be aware of the risk of displacement of the CI magnet after (minor) head injury. Young boys tend to have a higher risk for this complication.

  19. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  20. Leadless pacemaker implantation in a patient with complex congenital heart disease and limited vascular access

    Directory of Open Access Journals (Sweden)

    Paolo Ferrero

    2016-11-01

    Full Text Available Management of rhythm related issues might be particularly challenging in patients with congenital heart disease due to complex anatomy and restricted vascular access. The leadless technology appears a suitable and attractive alternative for this population. We describe a patient with single ventricle physiology who successfully underwent implantation of a leadless pacemaker.

  1. An Unusual Bone Loss Around Implants

    Directory of Open Access Journals (Sweden)

    Amirreza Rokn

    2013-01-01

    Full Text Available AbstractPre-implant disease is an inflammatory process, which can affect the surrounding tissues of a functional Osseointegrated implant that is usually as a result of a disequilibrium between the micro-flora and the body defense system.This case reports a 57 years old male with unusual bone loss around dental implants.This was an unusual case of peri-implantitis which occurred only in the implants on one side of the mouth although they all were unloaded implants.

  2. Immediate prostheses on one-piece trans-mucosal implants in flapless surgical procedures Case Series Report. Part I: full arch rehabilitations

    Directory of Open Access Journals (Sweden)

    Aris Petros Tripodakis

    2012-06-01

    Full Text Available Aim: The aim of the present case series report is to illustrate a clinical technique and present the application of onepiece transmucosal implants in flapless surgical procedures, supporting full arch immediate prostheses. Materials and methods: A total of 294 implants (Xive TG, Friadent, Germany have been used to support full arch immediate prostheses, over the last six years and have been in function for at least one year. The surgical placement of five or more implants per case involved immediate extraction and intrasocket flapless placement, combined with minimal flap elevation in the areas of healed extraction sites (43 mandibular and 7 maxillary arches. In all cases immediate provisionalization followed. Detailed three-dimensional cone-beam localized volumetric tomography preceeded the surgical procedures. The delivery of the final ceramo-metal prostheses was accomplished within a 20 day period. Materials and methods: Results Six implants failed to osseointegrate. All other implants are still successfully bearing the final prosthesis for the time that they have been followed. Soft tissue reaction was favorable from both the biologic and esthetic point of view. Conclusion: The flapless placement of one piece implants into edentulous healed sites is a predictable procedure in the presence of abundance of supporting bone as confirmed by 3-D imaging. On the other hand, immediate extraction placement of one piece implants allows the engagement of sound bone located deeper into the socket and provides adequate mechanical support of the soft tissue architecture that is preserved predictably. In all cases the prosthetic procedures are accomplished without disturbing the hardsoft tissue interface as the abutment-prosthesis interface is coronally elevated by the virtual design of the implant.

  3. Acute Immunologic Reaction to Silicone Breast Implant after Mastectomy and Immediate Reconstruction: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Massoome Najafi

    2014-08-01

    Full Text Available Background: Since the introduction of silicone based medical devices in to clinical practice, several reports appeared in the medical literature regarding their adverse effects. However, there are few reports of immunologic reactions to these implants.Case presentation: A case of systemic reaction to a breast implant inserted for immediate breast reconstruction in a breast cancer patient is presented. The patient developed fever and skin rash two months after the surgery. Investigations disclosed no infectious origin for the fever and a dramatic response to steroid therapy was observed.Conclusion: Immunologic reaction should be considered in case of systemic signs and symptoms after silicone breast implant placement as a rare complication. 

  4. Determining factors for implant referral rates.

    Science.gov (United States)

    Levin, Roger P

    2002-01-01

    The research findings indicate that the field of implant dentistry will only grow at a moderately low level unless certain changes are made. Findings indicated that the effort by the implant companies has been nothing short of dramatic, and yet almost 60% of restorative doctors do not participate annually in any implant case. There was no clear indication that younger restorative doctors will significantly increase the number of implant referrals, as their overall implant education has not dramatically differed from those dentists who graduated in earlier years. Once the research was completed, it became obvious to Levin Group that the driving force behind implant referral growth will be implant surgeons, because of their one-to-one relationship with restorative doctors. The Levin Group Implant Management and Marketing Consulting Program is based on approaching restorative doctors in several different levels, starting with awareness all the way through to case facilitation and long-term tracking and communication. Finally, a continuing marketing/education effort needs to be consistently in place with effective materials, not only to create a high level of awareness, but also to motivate restorative doctors to refer cases and then work through the case with the implant surgeon to a satisfactory completion for the restorative doctor, implant surgeon, and patient. While the surgical insertion of implants may seem to carry a high-profit margin relative to the restoration of implants, the truth is that the restoration of implants usually provides a 40% higher profit margin for the restorative doctor than traditional dental services. One of the key issues is that referring doctors have not necessarily learned how to set fees and present cases with regard to implant dentistry. The key factor here is to ensure that the patient understands that implant services involve higher fees than traditional services, because of the necessarily higher levels of experience, education

  5. Implant-retained overdentures for young children with severe oligodontia: a series of four cases.

    Science.gov (United States)

    Filius, Marieke A P; Vissink, Arjan; Raghoebar, Gerry M; Visser, Anita

    2014-09-01

    The treatment need is high in children with severe oligodontia and anodontia, because they often have functional and esthetic problems owing to missing teeth. Because the intraforaminal region barely grows after eruption of the permanent mandibular incisors, dental implant treatment should be considered a treatment option for these children. The purpose of our study was to assess the treatment outcomes regarding satisfaction and the care and aftercare of implant-retained mandibular overdentures in a series of 4 young children without erupted mandibular teeth from either severe oligodontia (n = 3) or anodontia (n = 1). Four children without erupted mandibular teeth, aged 6 to 13 years, were provided with an implant-retained overdenture on 2 implants. The surgical and prosthetic care and aftercare were scored by the clinicians. Also, the patients and their parents were queried about how satisfied they were with the overdenture. The median follow-up of the patients was 5.2 years (range 3.2 to 8.4). No implants were lost, no cases of peri-implantitis occurred, and the need for treatment and aftercare was low. Patient and parent satisfaction with this treatment was high. A 2-implant, retained overdenture in children with no erupted mandibular teeth is a safe treatment modality when appropriate treatment and aftercare can be provided. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Complex regional pain syndrome type I following pacemaker implantation

    Directory of Open Access Journals (Sweden)

    Sangita Kamath

    2015-12-01

    Full Text Available A 70-year-old woman presented with burning pain and swelling over dorsum of right hand and small joints of the fingers, associated with redness, feeling of warmth, and stiffness of the fingers, with inability to bend the fingers since 2 months. The symptoms were progressively increasing in intensity for the past 1 month. There was no history of fever or trauma to the hand. Two months before her symptoms started, she had permanent pacemaker implanted for complete heart block with syncope. She was hypertensive and was on regular medication. Her X-ray of right hand showed decreased bone density (demineralisation, suggestive of osteopenia. A diagnosis of reflex sympathetic dystrophy syndrome or complex regional pain syndrome type I induced by pacemaker insertion was made. She was treated with amitriptyline and steroids, after which her symptoms improved dramatically.

  7. Using individual two-posterior short implants with two-anterior standard implants in mandibular implant-supported-overdenture to enhance the patient satisfaction: A clinical report

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-01-01

    Full Text Available Introduction: Many clinical cases and the literature review have revealed implant-supported-overdentures’ (ISOs treatment success and predictability in elderly patients. According to the previous studies, all the mandibular ISOs used 2–4 implants anterior to mental foramen to retain the denture. Case Report: In this clinical report, two individual anterior standard implants and two individual posterior short implants were used to support the mandibular ISO, as well as to prevent further posterior bone resorption. This treatment option permits the patient to insert more implants in the future, and could be upgraded to implant-supported-fixed prosthesis. Discussion: The patient was completely satisfied about the final result, especially for upgrading the mastication efficiency. The patient was followed-up for more than 2 years without complication. The panoramic X-ray showed the preserved bone in the posterior region. This technique could be considered to be innovative, and more clinical cases are required to be documented as a predictable modality.

  8. Combined piezosurgery and selective distraction osteogenesis to correct malpositioned implants: a case report.

    Science.gov (United States)

    Parma-Benfenati, Stefano; Maino, Giuliano B

    2015-01-01

    This case report shows the combined use of piezosurgical and orthodontic procedures to successfully relocate two severely malpositioned implants in the anterior maxilla by moving them separately, with the objective of attaining functional prosthetic restoration and acceptable esthetics.

  9. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    OpenAIRE

    Kim, Chang-Soon; Duong, Hieu Pham; Park, Jung-Chul; Shin, Hyun-Seung

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-...

  10. Plasma-implantation-based surface modification of metals with single-implantation mode

    Science.gov (United States)

    Tian, X. B.; Cui, J. T.; Yang, S. Q.; Fu, Ricky K. Y.; Chu, Paul K.

    2004-12-01

    Plasma ion implantation has proven to be an effective surface modification technique. Its biggest advantage is the capability to treat the objects with irregular shapes without complex manipulation of target holder. Many metal materials such as aluminum, stainless steel, tool steel, titanium, magnesium etc, has been treated using this technique to improve their wear-resistance, corrosion-resistance, fatigue-resistance, oxidation-resistance, bio-compatiblity etc. However in order to achieve thicker modified layers, hybrid processes combining plasma ion implantation with other techniques have been frequently employed. In this paper plasma implantation based surface modification of metals using single-implantation mode is reviewed.

  11. Distant Migration of Multiple Siliconomas in Lower Extremities following Breast Implant Rupture: Case Report.

    Science.gov (United States)

    Oh, Joo Hyun; Song, Seung Yong; Lew, Dae Hyun; Lee, Dong Won

    2016-10-01

    Siliconoma from ruptured breast implants has been reported in multiple body sites, including but not limited to the breast parenchyma, axillary lymph nodes, upper arm, and even lower leg. In this regard, we report a rare case of distant silicone migration to the lower extremities after traumatic breast implant rupture. A 55-year-old Asian woman who received bilateral augmentation mammoplasty 20 years ago presented with ruptured breast implants from a car accident 2 years earlier. Magnetic resonance imaging confirmed intracapsular and extracapsular rupture of the right breast implant, showing "linguine sign." We removed the bilateral breast implants and performed capsulectomy and bilateral reduction mammoplasty using inverted-T incisions. The implant was confirmed as a smooth, silicone gel-filled mammary implant of 125 cm 3 by a Japanese manufacturer, Koken. During her regular follow-up outpatient visits, physical examination revealed 2.5- × 1.5-cm ill-defined, tender, subcutaneous nodules on both knees and 8.5- × 3.0-cm inflammatory changes in the inguinal area with persistent pain. Computed tomography showed no definite mass, but rather infiltrative, nonenhancing soft-tissue densities in the subcutaneous layers of the bilateral inguinal and knee areas. Surgical excision was performed, and pathologic findings confirmed variable vacuoles with foreign body reaction and fibrosis, consistent with siliconoma. It is important to acknowledge that siliconomas can be encountered in patients with ruptured breast implants, especially those manufactured decades ago. Our patient with masses as remote as the inguinal and knee areas is a prime example of how far siliconomas can migrate.

  12. Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report.

    Science.gov (United States)

    Oh, Ji-Hyeon; An, Xueyin; Jeong, Seung-Mi; Choi, Byung-Ho

    2017-12-01

    The purpose of this article was to describe a fully digital workflow used to perform computer-guided flapless implant placement in an edentulous patient without the use of conventional impressions, models, or a radiographic guide. Digital data for the workflow were acquired using an intraoral scanner and cone-beam computed tomography (CBCT). The image fusion of the intraoral scan data and CBCT data was performed by matching resin markers placed in the patient's mouth. The definitive digital data were used to design a prosthetically driven implant position, surgical template, and computer-aided design and computer-aided manufacturing fabricated fixed dental prosthesis. The authors believe this is the first published case describing such a technique in computer-guided flapless implant surgery for edentulous patients. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Osseointegrated implants and auricular defects: a case series study.

    Science.gov (United States)

    Wright, Robert F; Zemnick, Candice; Wazen, Jack J; Asher, Eric

    2008-08-01

    The objective of this study was to report on the survival rate of 16 patients treated with extraoral implants in the auricular region, analyze treatment outcomes, and discuss important clinical variables encountered during treatment. Sixteen patients who received extraoral dental implants to retain auricular prostheses between 1987 and 2003 were followed retrospectively. The variables recorded were gender, initial diagnosis, number and size of implants, implant placement date, age at implant placement, history of radiation to the treated field, abutment size, design of initial prosthesis, age of initial prosthesis (when a remake was indicated), date of prosthesis delivery, soft tissue response, grafting procedure, date of last follow-up, and complications. All patients were thoroughly evaluated presurgically by the reconstruction team, which consisted of prosthodontists, a facial prosthetist, and an otolaryngologist. Surgical templates were used for all patients. The criteria for success of the prostheses included marginal accuracy, overall stability and function, symmetry/position, texture, color stability, and patient acceptance. Thirty-nine implants were placed in 16 patients. All 16 patients were completely satisfied with their reconstructions. No surgical complications, implant failures, or prosthetic failures were encountered. Therefore, the survival rate was 100%. Three patients (18.75%) had grade 0, seven (43.75%) had grade 1, five (31.25%) had grade 2, and one (6.25%) had grade 3 soft tissue inflammation. The inflammation completely resolved in 7 of the 13 patients (54%) with hygiene reinforcement or soft tissue reduction. The survival rate for bone-anchored titanium implants and prostheses was 100%. Bone-anchored titanium implants provided the 16 patients in this study with a safe, reliable, adhesive-free method to anchor auricular prostheses with recovery of normal appearance. Under the guidance of an appropriate implant team, proper positioning of

  14. Recoil implantation reactions in binary mixtures of catcher complexes and in mixed ligand catchers

    International Nuclear Information System (INIS)

    Sekine, Tsutomu; Sano, Masaaki; Yoshihara, Kenji

    1989-01-01

    Recoil implantation reactions were studied in binary mixtures of catcher complexes of tris(β-diketonato)metal(III) and in single-component catcher complexes of Cr(acac) n (dbm) 3-n where n=1 and 2. For the mixtures of M(acac) 3 and M(dbm) 3 , the products of 51 Cr(acac) 3 and 51 Cr(dbm) 3 were obtained as major components while 51 Cr(acac) 2 (dbm) and 51 Cr(acac)(dbm) 2 were seen as minor components. For the single component catcher complexes, predominant chemical species were parent retention type compounds. In addition to retentions there were product distributions which indicated a strong preference for acac pickup. The results were interpreted by a model which involves displacement reaction as a main process and ligand pickup reactions as side processes. (orig.)

  15. Decompression Retinopathy after ExPRESS Shunt Implantation for Steroid-Induced Ocular Hypertension: A Case Report

    Directory of Open Access Journals (Sweden)

    Khawla Abu Samra

    2011-01-01

    Full Text Available Purpose. To present a unique case of decompression retinopathy after the implantation of ExPRESS drainage device. Method. A 25-year-old female patient underwent implantation of ExPRESS drainage device in the left eye for the management of steroid-induced ocular hypertension. Results. On the postoperative day one, best-corrected visual acuity in the left eye was 20/50. Fundus examination revealed diffuse intraretinal hemorrhages, some white-centered, throughout the retina. There was also marked tortuosity to the retinal vasculature and no evidence of choroidal effusion. Intravenous fluorescein angiography and indocyanine green did not contribute to the aetiopathogenesis. Conclusion. Decompression retinopathy can occur following the implantation of ExPRESS drainage device. It is very important to be aware of this complication in patients with relatively high intraocular pressure who is planned for filtration surgery, including the ExPRESS implant.

  16. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    Science.gov (United States)

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  17. Reposição cirúrgico-ortopédica de implante mal posicionado: relato de caso Surgical-orthopedic repositioning of malpositioned implant: a case report

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Ferreira da Silva

    2005-06-01

    Full Text Available A reabilitação bucal por meio da colocação de implantes dentários tem se tornado um procedimento freqüente da clínica odontológica. Falhas no planejamento ou na execução da técnica podem levar a casos onde, apesar de osseointegrado, o implante não apresenta condições de restauração satisfatória devido ao seu mal posicionamento. Diversos autores têm relatado a possibilidade de se utilizar osteotomias segmentares de maxila ou mandíbula para reposicionar um segmento alveolar com implante, mostrando que esta pode ser uma técnica efetiva e previsível para restaurar implantes em posição anatômica comprometida. O presente trabalho apresenta o caso clínico de uma paciente de 20 anos de idade onde foi realizada osteotomia segmentar de maxila associada à distração osteogênica para correção de um implante mal posicionado.Oral rehabilitation through dental implants has become a common procedure at dental practice. However, if the implant is placed in an inappropriate position either because of inadequate presurgical planning or poor surgical technique, it may be unrestorable in spite of osseointegrated. Many authors have reported the possibility of using segmental maxillary or mandibular osteotomies to reposition an alveolar segment with its implants. This can be an effective, predictable technique for restoring implants in a compromised anatomic position. This paper presents a case report describing the use of this procedure associated to distraction osteogeneis to reposition one malpositioned implant in a 20 years old girl.

  18. Effect of recoiled O on damage regrowth and electrical properties of through-oxide implanted Si

    International Nuclear Information System (INIS)

    Sadana, D.K.; Wu, N.R.; Washburn, J.; Current, M.; Morgan, A.; Reed, D.; Maenpaa, M.

    1982-10-01

    High dose (4 to 7.5 x 10 15 cm -2 ) As implantations into p-type (100) Si have been carried out through a screen-oxide of thicknesses less than or equal to 775A and without screen oxide. The effect of recoiled O on damage annealing and electrical properties of the implanted layers has been investigated using a combination of the following techniques: TEM, RBS/MeV He + channeling, SIMS and Hall measurements in conjunction with chemical stripping and sheet resistivity measurements. The TEM results show that there is a dramatically different annealing behavior of the implantation damage for the through oxide implants (Case I) as compared to implants into bare silicon (Case II). Comparison of the structural defect profiles with O distributions obtained by SIMS demonstrated that retardation in the secondary damage growth in Case I can be directly related with the presence of O. Weak-beam TEM showed that a high density of fine defect clusters (less than or equal to 50A) were present both in Case I and Case II. The electrical profiles showed only 30% of the total As to be electrically active. The structural and electrical results have been explained by a model that entails As-O, Si-O and As-As complex formation and their interaction with the dislocations

  19. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  20. Unplanned complex suicide: Two case reports

    Directory of Open Access Journals (Sweden)

    Nikolić Slobodan

    2010-01-01

    Full Text Available Introduction The term complex suicide refers to suicides in which multiple suicidal methods are utilized, as opposed to simple suicide successfully done after one attempt. In planned complex suicides two or more methods are employed simultaneously in order to make sure that death will occur after failure of previous attempt. In unplanned complex suicides, several other methods of suicide tried after the first chosen method either failed or was too painful. Outline of Cases We report two cases of unplanned complex suicides. The first case was a female who first tried to commit suicide by cutting the wrists, and then hanged herself. In the other case, a male first tried to commit suicide by stubbing his chest with a knife, and then jumped into a well and drowned himself. In both reported cases the second, successful suicidal method was of higher lethality score. Conclusion From the forensic point of view, the presence of several injuries of different origin strongly suggests infliction by other person. The event could be reconstructed, based on autopsy findings and traces found at the scene. .

  1. “REPRESENTATION, PROJECTION AND COCHLEAR IMPLANT: A SINGLE CASE STUDY”

    Directory of Open Access Journals (Sweden)

    Carmela Mento

    2014-06-01

    Full Text Available From the psychological point of view hearing is an essential sensory modality for the human species, because it contributes to the formation of the first relational connections and emotions. It is important to make a diagnosis early to intervene and limit negative effects.  Deafness is a particular phenomenon (onset, types,  in this paper we undertake a thorough descriptive analysis on all aspects of deafness, in particular the use of a prosthetic device known as cochlear implant.  We have deepened personality variables in a single case with the use of Rorschach Test and Draw-a-person-Test.  We aimed to study, with the clinical interpretation of instruments, which personality variables could be involved in hearing loss condition and Cochlear Implant (CI.  This observational study highlights the psychological dynamics that should be taken into account by operators team, in order to improve the quality of life of these patients and increase their long-term therapeutic outcome.

  2. Probabilistic analysis of preload in the abutment screw of a dental implant complex.

    Science.gov (United States)

    Guda, Teja; Ross, Thomas A; Lang, Lisa A; Millwater, Harry R

    2008-09-01

    screw at high values of the preload CDF. Lubrication at the threaded surfaces between the abutment screw and implant bore affects the preload developed in the implant complex. For the well-lubricated surfaces, only approximately 50% of implants will have preload values within the generally accepted range. This probability can be improved by applying a higher torque than normally recommended or a more closely controlled torque than typically achieved. It is also suggested that materials with higher elastic moduli be used in the manufacture of the abutment screw to achieve a higher preload.

  3. Management of Broken Dental Implant Abutment in a Patient with Bruxism: A Rare Case Report and Review of Literature.

    Science.gov (United States)

    Al-Almaie, Saad

    2017-01-01

    This rare case report describes prosthodontic complications resulting from a dental implant was placed surgically more distally in the area of the missing mandibular first molar with a cantilever effect and a crest width of >12 mm in a 59-year-old patient who had a history of bruxism. Fracture of abutment is a common complication in implant was placed in area with high occlusal forces. Inability to remove the broken abutment may most often end up in discarding the implant. Adding one more dental implant mesially to the previously placed implant, improvisation of technique to remove the broken abutment without sacrificing the osseointegrated dental implant, fabrication with cemented custom-made abutment to replace the broken abutment for the first implant, and the use of the two implants to replace a single molar restoration proved reliable and logical treatment solutions to avoid these prosthodontic complications.

  4. Management of broken dental implant abutment in a patient with bruxism: A rare case report and review of literature

    Directory of Open Access Journals (Sweden)

    Saad Al-Almaie

    2017-01-01

    Full Text Available This rare case report describes prosthodontic complications resulting from a dental implant was placed surgically more distally in the area of the missing mandibular first molar with a cantilever effect and a crest width of >12 mm in a 59-year-old patient who had a history of bruxism. Fracture of abutment is a common complication in implant was placed in area with high occlusal forces. Inability to remove the broken abutment may most often end up in discarding the implant. Adding one more dental implant mesially to the previously placed implant, improvisation of technique to remove the broken abutment without sacrificing the osseointegrated dental implant, fabrication with cemented custom-made abutment to replace the broken abutment for the first implant, and the use of the two implants to replace a single molar restoration proved reliable and logical treatment solutions to avoid these prosthodontic complications.

  5. Silicone implant incompatibility syndrome (SIIS) in a 57-year-old woman with unilateral silicone breast implant

    DEFF Research Database (Denmark)

    Schierbeck, Juliane; Davidsen, Jesper Rømhild; Grindsted Nielsen, Sanne

    2017-01-01

    implants can lead to different interstitial lung manifestations predominantly with granuloma evolvement, leading to the so-called silicone implant incompatibility syndrome (SIIS). This case describes a 57-year-old woman with multiple lung infiltrations and a left-sided breast implant. The implant had been...

  6. Use of Prothrombin Complex Concentrate in Patients during Heart Transplantation after Implantation of a Left Ventricular Mechanical Support System

    Directory of Open Access Journals (Sweden)

    V. V. Lomivorotov

    2012-01-01

    Full Text Available Heart transplantation in patients after implantation of mechanical cardiac support devices entails an extremely high risk for perioperative bleeding. Recombinant activated coagulation factor VII is presently used to reduce the volume of bleeding in this patient group. There are parallel data on its administration-induced thromboembolic events in the literature. This paper describes a case of using a prothrombin complex concentrate in a patient during explantation of a left ventricular bypass system and subsequent orthotopic heart transplantation in the presence of significant hypocoagulation. At the end of a surgery, 1200 IU of the agent was used at a remaining bleeding rate of more than 1000 ml/hour. Within the first 24 hours after surgery, the rate of discharge drainage was less than 100 ml/hour. A control plain chest X-ray study revealed massive left-sided hydrothorax on day 2 postsurgery. The left pleural cavity was revised under thoracoscopic guidance and 1000 ml of blood clots were evacuated. Although the administration of prothrombin complex concentrate did not guard against re-intervention, its use seems a promising strategy in life-threatening bleedings in patients after explantation of mechanical cardiac support devices. Further multicenter investigations are required to determine the efficacy and safety of prothrom-bin complex concentration in cardiac surgery. Key words: Recombinant activated coagulation factor VII, prothrombin complex concentration, mechanical cardiac support device, orthotopic heart transplantation.

  7. A new condyle implant design concept for an alloplastic temporomandibular joint in bone resorption cases.

    Science.gov (United States)

    Ramos, António; Mesnard, Michel

    2016-10-01

    The purpose of this article is to present and evaluate an innovative intramedullary implant concept developed for total alloplastic reconstruction in bone resorption cases. The main goal of this innovative concept is to avoid the main problems experienced with temporomandibular (TMJ) devices on the market, associated with bone fixation and changes in kinematics. A three-dimensional finite element model was developed based on computed tomography (CT) scan images, before and after implantation of the innovative implant concept. To validate the numerical model, a clean cadaveric condyle was instrumented with four rosettes and loaded before and after implantation with the innovative concept TMJ implant. The experimental results validate the numerical models comparing the intact and implanted condyles, as they present good correlation. They show that the most critical region is around rosette #1, with an increase in strains in the proximal region of the condyle of 140%. The maximum principal strain and stress generated with the implant is less than 2200 με and 75 MPa in the posterior region of the cortical bone. Shortly after insertion of this press-fit implant, stress and strain results appear to be within the normal limits and show some similarities with the intact condyle. If these responses do not change over time, the screw fixation used at present could be avoided or replaced. This solution reduces bone resection and lessens surgical damage to the muscles. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Electroconvulsive therapy in patients with skull defects or metallic implants: a review of the literature and case report.

    Science.gov (United States)

    Amanullah, Shabbir; Delva, Nicholas; McRae, Harold; Campbell, Laura A; Cole, Julie

    2012-01-01

    Head injury is often associated with psychiatric morbidity. While it is well understood that the loss of critical areas of the brain may play a role in cognitive dysfunction and change in personality, head injury can also have profound effects on mood and cognition. The role of medications in the treatment of mood disorders associated with brain injury is well documented, and there is also evidence favoring the use of electroconvulsive therapy (ECT) in this context. However, data are limited on the use of ECT in patients with skull defects or metallic head implants. First, a review of the literature on use of ECT in patients with metallic head implants is provided. Electronic databases and online sites, including PubMed, Cochrane Library of Systematic Reviews, and UpToDate, were used to search for relevant articles and case reports on the use of ECT in patients with and without metallic implants in the head (1964 to 2009). The search terms electroconvulsive, electroconvulsive therapy, ECT, electroshock therapy, EST, head injury, brain injury, metallic plates, metallic implants, skull prosthesis, and depression were used interchangeably. The search produced 7 articles discussing exclusively the use of ECT in patients with a metallic skull plate. Second, the case of the successful and safe use of ECT in an individual with a previous history of brain trauma and metallic plate implantation is described. Most cases of head injury are managed by neurologists and rehabilitation consultants; the more severe cases of depression and other mood disorders tend to be referred for specialist psychiatric care. With greater degrees of deficit following head injury, management becomes more complicated. Our patient showed positive results with ECT, including improvement in depressive features and resolution of suicidal ideas/plans. ECT is an effective and safe alternative in patients with a history of brain trauma and metallic plate implantation who subsequently develop treatment

  9. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series.

    Science.gov (United States)

    Gay-Escoda, C; Pérez-Álvarez, D; Camps-Font, O; Figueiredo, R

    2016-05-01

    The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Nine participants (57 implants) were included. The patients' median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented.

  10. R&D on dental implants breakage

    Science.gov (United States)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  11. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  12. Application of the 2-piece orthodontic C-implant for provisional restoration with laser welded customized coping: a case report.

    Science.gov (United States)

    Paek, Janghyun; Ahn, Hyo-Won; Jeong, Do-Min; Shim, Jeong-Seok; Kim, Seong-Hun; Chung, Kyu-Rhim

    2015-03-25

    This article presents the application of laser welding technique to fabricate an orthodontic mini-implant provisional restoration in missing area after limited orthodontic treatment. A 15-year-old boy case is presented. Two-piece orthodontic C-implant was placed after regaining space for missing right mandibular central incisor. Due to angular deviation of implant, customized abutment was required. Ready-made head part was milled and lingual part of customized abutment was made with non-precious metal. Two parts then were laser welded (Master 1000, Elettrolaser Italy, Verona, Italy) and indirect lab composite (3 M ESPE Sinfony, St. Paul, MN, USA) was built up. The patient had successful result, confirmed by clinical and radiographic examinations. Before the patient is ready to get a permanent restoration later on, this provisional restoration will be used. This case shows that a two-piece orthodontic C-implant system can be used to maintain small edentulous space after orthodontic treatment.

  13. Penile prosthesis implant with bi-triangular excision and graft for surgical therapy of Peyronie’s disease: A case report

    Directory of Open Access Journals (Sweden)

    Alexandre de Freitas Miranda

    2016-01-01

    Full Text Available We present a case of a 65-year-old man, who presented with moderate erectile dysfunction and a dorsal penile deviation of 60° caused by Peyronie’s disease. The patient underwent bi-triangularshaped plaque excision, followed by grafting and implantation of inflatable penile prosthesis. Complete penile straightening, without mechanical or geometric abnormalities, was achieved using bi-triangular excision and grafting. Postoperatively, the patient reported high satisfaction with the results and could perform sexual intercourse naturally. This novel technique corrects any degree of penile curvature, permits malleable and semi-rigid penile prosthesis implantation, avoids penile length loss, and eliminates additional incisions. To our knowledge, this case is the first in the literature in which the bi-triangular technique was successfully used for penile prosthesis implantation secondary to Peyronie’s disease. This new technique appears to be a good solution to correct penile curvature during penile prosthesis implantation for the treatment of Peyronie’s disease associated with erectile dysfunction.

  14. A 128-slice CT scanner helpful in localising coronary sinus ostium during CRT-D implantationcase report

    International Nuclear Information System (INIS)

    Jaźwiec, Przemysław; Jagielski, Dariusz; Gać, Paweł

    2014-01-01

    Cardiac resynchronization therapy (CRT) has become a successful treatment option for symptomatic heart failure in patients with poor left ventricular (LV) systolic function and broad QRS complex in the surface electrocardiogram (ECG). In this report we present a case of a 70-year-old woman with advanced heart failure due to ischaemic heart disease who underwent an upgrade from VVIR stimulator (pacemaker, PM) to cardiac resynchronization therapy defibrillator (CRT-D). The first attempt was unsuccessful due to problems with inefficient cannulation of the orifice of the coronary sinus (CS). After performing a 3D reconstruction with a 128-slice CT scanner, it was possible to carry out the up-grade to CRT-D resulting in enormous clinical improvement. The case represents an example of the usefulness of 3D reconstruction with the 128-slice CT scanner used after failed CRT-D implantation due to difficulties with efficient cannulation of the coronary sinus orifice in a rare anatomical variant

  15. Management of complex long bone nonunions using limb reconstruction system

    Directory of Open Access Journals (Sweden)

    Hiranya Kumar Seenappa

    2013-01-01

    Full Text Available Background: Management of complex nonunions is difficult due to the presence of infection, deformities, shortening and multiple surgeries in the past. Complex nonunions are traditionally managed by Ilizarov fixation. The disadvantages of Ilizarov are poor patient compliance, inconvenience of the frame and difficult frame construction. We conducted a study on 30 long bone complex nonunions treated by the limb reconstruction system (LRS. Materials and Methods: Between April 2009 and September 2012, we treated 30 cases of complex nonunion of long bone with the LRS. 28 were male and 2 females. Average shortening was 5.06 cm and 14 cases presented with infected implants. Initially we managed with implant removal, radical debridement followed by fixation with the LRS. In 16 cases, corticotomy and lengthening was done. The average duration of treatment was 9.68 months. We compressed the fracture site at the rate of 0.25 mm per day for 1-2 weeks and distracted the corticotomy at the rate of 1 mm/day till lengthening was achieved. Result: The union occurred in 89.28% cases and eradication of infection in 91.66% cases. Average lengthening done was 4.57 cm. We had 79% excellent, 11% good and 10% poor bony result and fnctional result was excellent in 40% cases, good in 50% and failure in 10% cases using ASAMI scoring system. Conclusion: LRS is an alternative to the Ilizarov fixation in their management of complex nonunion of long bones. It is less cumbersome to the patient and more surgeon and patient friendly.

  16. Histology of peri-implant bone in a failed implant retrieved from an area of osteonecrosis of the jaw in a patient suffering from multiple myeloma and treated with intravenous bisphosphonates

    Directory of Open Access Journals (Sweden)

    Marco Degidi

    2012-03-01

    Full Text Available Background: Osteonecrosis of the jaw (ONJ has been reported in the past few years in patients undergoing treatment with bisphosphonates (BP. Few published histological studies of ONJ can be found in the literature and no study has been reported on the peri-implant bone around a dental implant retrieved from an area of ONJ. The aim of the present case was to report the histology of the peri-implant bone around an implant retrieved from an area of ONJ. Materials and methods: Multiple myeloma was diagnosed to a 72-year-old male. The patient underwent treatment with intravenous pamidronate for 2 years and with intravenous zoledronate for additional 3 years. Five years after the diagnosis, 7 immediately loaded dental implants were inserted in the mandible. A preoperative panoramic radiography did show no pre-existing bone lesions. No healing of the post-extraction sockets of the right third molar and of the left second molar was observed. Three years after the implant insertion a breakdown of the oral mucosa covering the implants was observed. The most distal implant was retrieved with a trephine bur, due to mobility. Discussion: The histological findings showed some areas with osseointegration in patients undergoing BP treatment for malignant disease. Conclusion: There is certainly a temporal association between BP use and development of ONJ, but a correlation does not necessarily mean causation. Moreover, generalisations about this complex relationship cannot be made on the basis of a single case report. In patients undergoing intravenous treatment, clinicians must be aware of the increased risk of implant failure and, probably, implant insertion should be avoided at all, until more conclusive data are available.

  17. Matrix-induced autologous chondrocyte implantation for a large chondral defect in a professional football player: a case report

    Directory of Open Access Journals (Sweden)

    Beyzadeoglu Tahsin

    2012-06-01

    Full Text Available Abstract Introduction Matrix-assisted autologous chondrocyte implantation is a well-known procedure for the treatment of cartilage defects, which aims to establish a regenerative milieu and restore hyaline cartilage. However, much less is known about third-generation autologous chondrocyte implantation application in high-level athletes. We report on the two-year follow-up outcome after matrix-assisted autologous chondrocyte implantation to treat a large cartilage lesion of the lateral femoral condyle in a male Caucasian professional football player. Case presentation A 27-year-old male Caucasian professional football player was previously treated for cartilage problems of his left knee with two failed microfracture procedures resulting in a 9 cm2 Outerbridge Grade 4 chondral lesion at his lateral femoral condyle. Preoperative Tegner-Lysholm and Brittberg-Peterson scores were 64 and 58, and by the second year they were 91 and 6. An evaluation with magnetic resonance imaging demonstrated filling of the defect with the signal intensity of the repair tissue resembling healthy cartilage. Second-look arthroscopy revealed robust, smooth cartilage covering his lateral femoral condyle. He returned to his former competitive level without restrictions or complaints one year after the procedure. Conclusions This case illustrates that robust cartilage tissue can be obtained with a matrix-assisted autologous chondrocyte implantation procedure even after two failed microfracture procedures in a large (9 cm2 cartilage defect. To the best of our knowledge, this is the first case report on the application of the third-generation cell therapy treatment technique, matrix-assisted autologous chondrocyte implantation, in a professional football player.

  18. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    Science.gov (United States)

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  19. Intracameral air injection during Ahmed glaucoma valve implantation in neovascular glaucoma for the prevention of tube obstruction with blood clot: Case Report.

    Science.gov (United States)

    Hwang, Sung Ha; Yoo, Chungkwon; Kim, Yong Yeon; Lee, Dae Young; Nam, Dong Heun; Lee, Jong Yeon

    2017-12-01

    Glaucoma drainage implant surgery is a treatment option for the management of neovascular glaucoma. However, tube obstruction by blood clot after Ahmed glaucoma valve (AGV) implantation is an unpredictable clinically challenging situation. We report 4 cases using intracameral air injection for the prevention of the tube obstruction of AGV by blood clot. The first case was a 57-year-old female suffering from ocular pain because of a tube obstruction with blood clot after AGV implantation in neovascular glaucoma. Surgical blood clot removal was performed. However, intractable bleeding was noted during the removal of the blood clot, and so intracameral air injection was performed to prevent a recurrent tube obstruction. After the procedure, although blood clots formed around the tube, the tube opening where air could touch remained patent. In 3 cases of neovascular glaucoma with preoperative severe intraocular hemorrhages, intracameral air injection and AGV implantation were performed simultaneously. In all 3 cases, tube openings were patent. It appears that air impeded the blood clots formation in front of the tube opening. Intracameral air injection could be a feasible option to prevent tube obstruction of AGV implant with a blood clot in neovascular glaucoma with high risk of tube obstruction. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  20. Implant retained auricular prosthesis with a modified hader bar: a case report.

    Science.gov (United States)

    Lovely, M; Dathan, Pradeep C; Gopal, Dinesh; George, Biji Thomas; Chandrasekharan Nair, K

    2014-06-01

    Auricular prostheses for defects of external ear are retained either by mechanical means or implants. All implant retained prostheses are retained by various means such as bar and clip, magnetic attachments or a combination of bar, clip and magnets. The commonest problem encountered with the bar and clip system is loosening of the clip after 3-4 months. When magnets are used as retaining component they tend to corrode over a period of time. So various alternative retention methods which possess good retentive qualities, ease of reparability and patient friendly were tried. In the present case a newly modified Hader bar design which can act as an additional retentive feature apart from the clip is employed to increase retention. The major advantages in the modified Hader bar system were that only two implants were employed, the additional loops in the Hader bar prevented micro movements and the retentive acrylic locks were easy to repair if broken. The modified Hader bar has anti-rotational slots which prevents the sliding or rotation of the prosthesis which gave new confidence to the patient who was otherwise worried of inadvertent displacement of the ear prosthesis while playing.

  1. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  2. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    Science.gov (United States)

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (Pprefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215

  3. Improving surgical results in complex nerve anatomy during implantation of selective upper airway stimulation.

    Science.gov (United States)

    Zhu, Zhaojun; Hofauer, Benedikt; Heiser, Clemens

    2018-06-01

    The following report presents a case of two late embedded hypoglossus branches during implantation of an upper airway stimulation device that caused a mixed activation of the tongue when included in the stimulation cuff. In the end, correct cuff placement could be achieved by careful examination of the hypoglossal nerve anatomy, precise nerve dissection, tongue motion analysis and intraoperative nerve monitoring. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  5. Cutaneous and systemic hypersensitivity reactions to metallic implants.

    Science.gov (United States)

    Basko-Plluska, Juliana L; Thyssen, Jacob P; Schalock, Peter C

    2011-01-01

    Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure. However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions remains to be fully understood. This review provides an update of the current knowledge in this field and should be valuable to health care providers who manage patients with conditions related to this field.

  6. Oral rehabilitation with implant supported overdentures in patients with non-reconstructed segmental mandibulectomy: A report of two cases

    Directory of Open Access Journals (Sweden)

    Rok Zupančič

    2013-11-01

    Full Text Available Background: Segmental mandibulectomy is most often performed as part of resection of advanced squamous cell carcinoma, which involves the mandible by extension from intraoral tissues and is usually followed by reconstruction of the mandible. However, not all mandibular defects can be surgically reconstructed, due to local or systemic factors. Oral rehabilitation with conventional removable dentures is often insufficient. In order to provide predictable support and denture retention, especially in the non-reconstructed cases of segmental mandibulectomy, dental implants are indicated.Case report: The authors describe oral rehabilitation with implant-supported overdenture in two non-reconstructed patients with similar mandibular defect, but different etiology, as well as different denture design and different outcome in terms of success and patient satisfaction. In the first case, the defect was caused by surgical treatment of cancer, which was followed by radiotherapy and prosthodontic treatment with an implant-supported mandibular overdenture anchored with a bar. In another case, the damage was due to a suicide attempt. This was initially followed by the surgical treatment of the injury. Afterwards, the prosthodontic treatment with an implant-supported and conical–crown-anchored mandibular overdenture was performed.Conclusions: The success of the prosthodontic oral rehabilitation of patients with segmental mandibulectomy depends on many factors. The size of the defect and the condition of the remaining hard and soft tissues, which are affected by radiotherapy, are crucial. The etiology of the defect, the opposing jaw status, maxillomandibular relationships, the consistency of mandibular movement and the denture design play an important role as well.

  7. Early Loading of Single-Piece Implant for Partially Edentulous Posterior Arch: A Prospective One-Year Case Report

    Directory of Open Access Journals (Sweden)

    Amol Beldar

    2013-01-01

    Full Text Available Implant therapy is now well established, and there is an increasing need for shorter rehabilitation time. Original prerequisites of osseointegration have been reassessed to satisfy continuously increasing patient's expectation of reduced treatment time, improved esthetics, and increased comfort. Shorter healing time may be appropriate in some circumstances, and examples of early loading have been reported in animal and human studies. However, to date there are insufficient data to determine a universally acceptable opinion on early loading of implants for single-tooth replacement. This case report involves early loading, combined with construction of a restoration, inserted directly after 6 weeks of implant surgery and followup of one year.

  8. An in vivo assessment of the effects of using different implant abutment occluding materials on implant microleakage and the peri-implant microbiome

    Science.gov (United States)

    Rubino, Caroline

    points were used to sample the peri-implant sulcus bacteria. All samples were then submitted to DNA purification, polymerase chain reaction (PCR), and sequencing protocols to assess relative numbers of bacterial species. Periodontal parameters were collected at both time points. Overall, our findings support several conclusions. Different implant abutment channel occluding materials appear to have no effect on the amount of observed microleakage and the peri-implant microbiome. Evidence for microleakage was found in the present study, corroborating existing in vivo evidence. Finally, we gained several insights regarding the peri implant microbiome. Of note, the peri-implant microbiome is well described by the classical periodontal microbial complexes, but a large portion consists of bacteria not previously classified into the microbial complexes.

  9. Everolimus-induced Pneumonitis after Drug-eluting Stent Implantation: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Susumu, E-mail: susumu1029@gmail.com; Kikuchi, Naoshi; Ichikawa, Atsuo; Sano, Go; Satoh, Keita; Sugino, Keishi; Isobe, Kazutoshi; Takai, Yujiro [Toho University School of Medicine, Department of Respiratory Medicine (Japan); Shibuya, Kazutoshi [Toho University School of Medicine, Department of Pathology (Japan); Homma, Sakae [Toho University School of Medicine, Department of Respiratory Medicine (Japan)

    2013-08-01

    Despite the wide use of everolimus as an antineoplastic coating agent for coronary stents to reduce the rate of restenosis, little is known about the health hazards of everolimus-eluting stents (EES). We describe a case of pneumonitis that developed 2 months after EES implantation for angina. Lung pathology demonstrated an organizing pneumonia pattern that responded to corticosteroid therapy. Although the efficacy of EES for ischemic heart disease is well established, EES carries a risk of pneumonitis.

  10. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  11. Pectus excavatum with delayed diagnosis of implant tear on MRI apparently causing recurrent postoperative seromas: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Iyer, Arti R.; Powell, Daniel K.; Irish, Robert D.; Math, Kevin R. [Mount Sinai Beth Israel Medical Center, Department of Radiology, New York, NY (United States)

    2015-08-15

    Seroma formation is the most common early postoperative complication after pectus excavatum repair, but later seromas are rare. While many seromas eventually resorb or decrease in size after aspiration, our case demonstrates recurrent seroma formation as a late complication of pectus excavatum repair in a patient with an implant tear. Postoperative seromas can result in prolonged chest wall pain, large chest wall masses, and increased mass effect on the heart with potential risk for resultant right ventricular outflow obstruction. This case report illustrates a solid silicone implant tear. Though rare, early recognition may help to decrease the likelihood of recurrent postoperative seromas. (orig.)

  12. [Tinnitus and implants].

    Science.gov (United States)

    Despreaux, G; Tison, P; Van Den Abbeele, T; Moine, A; Frachet, B

    1990-01-01

    The experience with cochlear implantation at Avicenne hospital prompted us to carry out a retrospective study on tinnitus in a population of operated patients. Improvement or disappearance of the symptoms was noted in all cases. These results, which partly match those found in the literature, are probably produced by rehabilitation inhibiting the "deafferentation" mechanisms in analogy with pain phenomena. In some precise cases, which are described, they led us to proposing implantation even though the main, if not sole, complaint of the patient was tinnitus.

  13. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  14. Origin for the shape of Au small crystals formed inside sapphire by ion implantation

    International Nuclear Information System (INIS)

    Ohkubo, M.; Hioki, T.

    1989-01-01

    In ion-implanted oxides, precipitation is usually formed except the case of forming solid solution. The precipitation comprises the metallic particles of implanted atoms, the oxide of implanted atoms, the metal of matrix elements, the compound of implanted atoms and matrix and so on. In particular, the metallic particles of implanted atoms are frequently faceted. From the facets, the equilibrium shape of crystals can be imagined. The equilibrium shape is determined so that the surface free energy is to be minimized. However, the shape of the metallic particles precipitated inside oxides should not be such equilibrium shape because they come in contact with foreign crystals. As the result, in the precipitation phenomena induced by ion implantation, the crystal structures of precipitated particles and substrates, the crystallographic relation between two crystals, interfacial energy and so on must be taken in consideration. In this paper, the report is made on the shape of the metallic gold particles formed inside sapphires by ion implantation that it was caused by only the crystal habit of sapphires regardless of the above-mentioned complexity. (K.I.)

  15. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  16. Radiologic images of an aggressive implant-associated fibromatosis of the breast and chest wall: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Lourdes Alanis, MD, MPH

    2017-09-01

    Full Text Available Fibromatosis of the breast is a rare benign disease compromising <0.2% of all primary breast tumors. Although the chest wall is a common location, occurrences of implant-associated fibromatosis of the breast are extremely rare; only 33 cases have been reported. We present a case of a 42-year-old female who underwent breast augmentation with silicone breast implants, and 2 years later developed an aggressive implant-associated fibromatosis of the breast and chest wall. On imaging studies, the tumor mimicked breast carcinoma, and despite chemotherapy, the fibromatosis rapidly enlarged and was locally invasive requiring wide surgical excision. Unlike previously reported imaging findings, magnetic resonance imaging revealed an oval circumscribed mass with fringe-like internal architecture. We provide a review of the literature and discuss the imaging features of implant-associated fibromatosis of the breast.

  17. Atypical Case of Three Dental Implants Displaced into the Maxillary Sinus

    Directory of Open Access Journals (Sweden)

    João Felipe Bonatto Bruniera

    2015-01-01

    Full Text Available Oral rehabilitation with dental implants has become a routine treatment in contemporary dentistry. The displacement of dental implants into the sinus membrane, a complication related to the maxillary sinus, is one of the most common accidents reported in the literature. The treatment for this complication is the surgical removal of the implant. A 60-year-old woman with three dental implants displaced into the maxillary sinus (one implant displaced into the left maxillary sinus and two implants displaced into the right maxillary sinus underwent surgery for removal of the implants. The surgery to remove the implants was performed under local anesthesia through the Caldwell-Luc technique. The patient was subsequently administered antibiotic, anti-inflammatory, and analgesic drugs. The patient returned 7 days after the surgery for suture removal and is being regularly monitored to determine whether future rehabilitation of the edentulous area is necessary. In conclusion, surgical removal of the dental implant displaced into the maxillary sinus is the treatment of choice. This technique is appropriate because it allows the use of local anesthesia and provides direct visualization for the removal of the implants.

  18. Management of broken dental implant abutment in a patient with bruxism: A rare case report and review of literature

    OpenAIRE

    Saad Al-Almaie

    2017-01-01

    This rare case report describes prosthodontic complications resulting from a dental implant was placed surgically more distally in the area of the missing mandibular first molar with a cantilever effect and a crest width of >12 mm in a 59-year-old patient who had a history of bruxism. Fracture of abutment is a common complication in implant was placed in area with high occlusal forces. Inability to remove the broken abutment may most often end up in discarding the implant. Adding one more den...

  19. Micro CT and human histological analysis of a peri-implant osseous defect grafted with porous titanium granules: a case report.

    Science.gov (United States)

    Wohlfahrt, Johan Caspar; Aass, Anne Merete; Ronold, Hans Jacob; Lyngstadaas, Stale Petter

    2011-01-01

    Treatment of peri-implant osseous defects represents a significant challenge for clinicians, and the need to evolve within predictable surgical procedures is important. This case report describes the surgical treatment and grafting with porous titanium granules (PTG) of one patient with a peri-implant osseous defect. The suggested thrombogenic properties of titanium are intriguing from the perspective of osseous reconstructive surgery. In an ongoing randomized clinical trial using PTG for treatment of peri-implant osseous defects, one patient with one test implant was excluded and scheduled for implant removal. The surgical therapy included open flap debridement with surface decontamination with 24% EDTA gel, grafting with PTG, and resubmersion of the implant. After 12 months of healing, the implant with surrounding tissues was excised en bloc and micro CT and histological analyses were performed. Analyses showed PTG in close contact with new bone and with bone growing both into the porosities of the graft material and onto the adjacent implant surface. Element analysis demonstrated calcium and phosphorus in the new tissue embedding the PTG and the implant. Int J Oral Maxillofac Implants 2011;26:e9-e14.

  20. Clinical application of single-tooth replacement with ankylos implant system

    International Nuclear Information System (INIS)

    Yang Xu; Liu Xue; Zhang Heng; Deng Yan; Guo Zhaozhong; Zhang Yufeng

    2011-01-01

    Objective: To evaluate the clinical effects of Ankylos implant system to restore the loss of single-tooth. Methods: 90 cases with loss of single-tooth were selected and treated with routinely two-stage surgery. When the patients presented with deficient alveolar ridge, guided bone regeneration (GBR), osteotome sinus floor elevation, lateral antrostomy surgery with simultaneous placement of implant were applied. They were restored with platinum ceramic crown. All the implants were followed up, and the records were kept about stability of the implant and abutment, the status of surrounding soft tissue, sealability of implant abutment junction and the marginal bone lossing through X-ray checking,and satisfaction of the patients to mastication and aspect of the restorations. The follow-up time was 1-2.5 years. Results: Among the cases,one case had peri-implant inflammation, and one case had porcelain dropped. No loosening occurred in the other implants and abuments. Implant abutment junction was sealed well. The marginal bone loss 1 year after final restoration was less than 1 mm. Soft tissue surrounding implants was healthy. The satisfaction rate was 98.9% (89/90). According to standard of implant success, 88 cases were successful, the 2.5-year cumulative success rate was 97.8%, 2 cases failed, and the failure rate was 2.2 %. Conclusion: A satisfactory treatment effects could be gotten by using Ankylos implant system to restore the loss of single-tooth. (authors)

  1. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  2. Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

    Science.gov (United States)

    Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-04-01

    Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location. We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type. After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.

  3. OLOGEN® implant in the management of glaucoma in an unusual case of Axenfeld-Rieger syndrome

    Directory of Open Access Journals (Sweden)

    O K Radhakrishnan

    2014-01-01

    Full Text Available We report an unusual case of Axenfeld-Rieger Syndrome with secondary glaucoma managed with Ologen® implant. A 35-year-old male presented with complaints of decreased vision in both eyes of 22 years duration. His best corrected visual acuity (BCVA was no perception of light in right eye and 20/30 in left eye. Gonioscopy revealed anterior insertion of iris into trabecular meshwork, prominent iris processes and broad-based synechiae with prominent Schwalbe′s line along the angle circumference with cord-like structures taking its origin at the level of Schwalbe′s line in both eyes. Fundus examination revealed total glaucomatous optic atrophy in right eye with 0.9:1 cup disc ratio with bipolar notch in left eye. Humphrey visual field analysis showed superior and inferior arcuate scotoma in left eye. Intraocular pressure measured by Goldman applanation tonometry was 30 mmHg and 26 mmHg in right and left eye, respectively. After an unsuccessful medical management, he underwent trabeculectomy with Ologen® implant under local anesthesia in his left eye. Postoperatively, at the end of one year, intraocular pressure (IOP in his left eye was controlled without medication. This case highlights the management of secondary angle closure glaucoma in Axenfeld-Rieger syndrome with Ologen® implant.

  4. Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants

    Directory of Open Access Journals (Sweden)

    Serkan Dundar

    2016-01-01

    Full Text Available The aim of this study was to examine the stress distributions with three different loads in two different geometric and threaded types of dental implants by finite element analysis. For this purpose, two different implant models, Nobel Replace and Nobel Active (Nobel Biocare, Zurich, Switzerland, which are currently used in clinical cases, were constructed by using ANSYS Workbench 12.1. The stress distributions on components of the implant system under three different static loadings were analysed for the two models. The maximum stress values that occurred in all components were observed in FIII (300 N. The maximum stress values occurred in FIII (300 N when the Nobel Replace implant is used, whereas the lowest ones, in the case of FI (150 N loading in the Nobel Active implant. In all models, the maximum tensions were observed to be in the neck region of the implants. Increasing the connection between the implant and the bone surface may allow more uniform distribution of the forces of the dental implant and may protect the bone around the implant. Thus, the implant could remain in the mouth for longer periods. Variable-thread tapered implants can increase the implant and bone contact.

  5. Type IV Hypersensitivity to Gold Weight Upper-Eyelid Implant: Case Report and Review of the Literature.

    Science.gov (United States)

    Kilduff, Caroline L S; Casswell, Edward J; Imonikhe, Richard; Marjanovic, Branka

    2017-05-04

    Complications associated with gold-weight insertion for lagophthalmos are uncommon, recent reports have provided evidence to suggest that type IV hypersensitivity to gold can cause a persistent inflammatory reaction. We present a case of a 46-year-old man who experienced persistent post-operative inflammation, and summarize previously documented cases. This patient underwent uncomplicated insertion of an upper eyelid gold weight for right-sided facial nerve palsy. He had no allergies or implanted metalwork. Post-operatively erythema was noted at seven-weeks and did not resolve. The weight was removed after six-months. The histopathological findings were in keeping with type IV hypersensitivity and similar to previous cases. Although infrequent, this complication has poor outcomes. The definitive management is removal of the weight. Information regarding implanted gold, and previous reactions should be elicited pre-operatively. Type IV hypersensitivity should be considered in patients with persistent inflammation that do not respond to antibiotic or steroid therapy.

  6. Rehabilitation of Posterior Maxilla with Obturator Supported by Zygomatic Implants

    Directory of Open Access Journals (Sweden)

    Sankalp Mittal

    2018-01-01

    Full Text Available Prosthetic rehabilitation of atrophic maxilla and large maxillary defects can be done successfully by zygomatic implant-supported prosthesis. Zygomatic implants are an avant-garde to complex and invasive-free vascularised osteocutaneous flaps, distraction osteogenesis, and the solution to flap failures. A treated case of tuberculous osteomyelitis, with a class II (Aramany’s classification maxillary defect, reported to oral maxillofacial department, Government Dental College (RUHS-CODS. The defect in this group was unilateral, retaining the anterior teeth. The patient was previously rehabilitated with a removable maxillary obturator. Inadequate retention affected essential functions like speaking, mastication, swallowing, esthetics, and so on due to lack of sufficient supporting tissues. A fixed prosthetic rehabilitation of posterior maxillary defect was done with obturator supported with two single-piece zygomatic implants. At 1-year follow-up, the patient was comfortable with the prosthesis, and no further complaints were recorded.

  7. Prosthodontic rehabilitation of hypophosphatasia using dental implants: a review of the literature and two case reports.

    LENUS (Irish Health Repository)

    Lynch, C D

    2009-06-01

    There are reports in the literature of the various dental features of hypophosphatasia, especially where it affects the deciduous dentition. The descriptions include both the manifestations of the disorder and the subsequent patterns of tooth loss. There are fewer descriptions of the effects of hypophosphatasia on the permanent dentition and little information on the subsequent prosthodontic management of these patients, particularly in relation to the use of dental implants. The aim of this paper was to review the literature on the dental effects of hypophosphatasia, present two cases and describe how one of those patients, a young adult, was successfully rehabilitated using dental implants. That latter patient\\'s pattern of tooth loss as well as some histological and scanning electron microscopic findings of root cementum from the other case is also described.

  8. The effects of micro-implant assisted rapid palatal expansion (MARPE) on the nasomaxillary complex--a finite element method (FEM) analysis.

    Science.gov (United States)

    MacGinnis, Matt; Chu, Howard; Youssef, George; Wu, Kimberley W; Machado, Andre Wilson; Moon, Won

    2014-08-29

    Orthodontic palatal expansion appliances have been widely used with satisfactory and, most often, predictable clinical results. Recently, clinicians have successfully utilized micro-implants with palatal expander designs to work as anchors to the palate to achieve more efficient skeletal expansion and to decrease undesired dental effects. The purpose of the study was to use finite element method (FEM) to determine the stress distribution and displacement within the craniofacial complex when simulated conventional and micro-implant-assisted rapid palatal expansion (MARPE) expansion forces are applied to the maxilla. The simulated stress distribution produced within the palate and maxillary buttresses in addition to the displacement and rotation of the maxilla could then be analyzed to determine if micro-implants aid in skeletal expansion. A three-dimensional (3D) mesh model of the cranium with associated maxillary sutures was developed using computed tomography (CT) images and Mimics modeling software. To compare transverse expansion stresses in rapid palatal expansion (RPE) and MARPE, expansion forces were distributed to differing points on the maxilla and evaluated with ANSYS simulation software. The stresses distributed from forces applied to the maxillary teeth are distributed mainly along the trajectories of the three maxillary buttresses. In comparison, the MARPE showed tension and compression directed to the palate, while showing less rotation, and tipping of the maxillary complex. In addition, the conventional hyrax displayed a rotation of the maxilla around the teeth as opposed to the midpalatal suture of the MARPE. This data suggests that the MARPE causes the maxilla to bend laterally, while preventing unwanted rotation of the complex. In conclusion, the MARPE may be beneficial for hyperdivergent patients, or those that have already experienced closure of the midpalatal suture, who require palatal expansion and would worsen from buccal tipping of the teeth

  9. Failure of Urological Implants in Spinal Cord Injury Patients due to Infection, Malfunction, and Implants Becoming Obsolete due to Medical Progress and Age-Related Changes in Human Body Making Implant Futile: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2013-01-01

    Full Text Available Any new clinical data, whether positive or negative, generated about a medical device should be published because health professionals should know which devices do not work, as well as those which do. We report three spinal cord injury patients in whom urological implants failed to work. In the first, paraplegic, patient, a sacral anterior root stimulator failed to produce erection, and a drug delivery system for intracavernosal administration of vasoactive drugs was therefore implanted; however, this implant never functioned (and, furthermore, such penile drug delivery systems to produce erection had effectively become obsolete following the advent of phosphodiesterase type 5 inhibitors. Subsequently, the sacral anterior root stimulator developed a malfunction and the patient therefore learned to perform self-catheterisation. In the second patient, also paraplegic, an artificial urinary sphincter was implanted but the patient developed a postoperative sacral pressure sore. Eight months later, a suprapubic cystostomy was performed as urethral catheterisation was very difficult. The pressure sore had not healed completely even after five years. In the third case, a sacral anterior root stimulator was implanted in a tetraplegic patient in whom, after five years, a penile sheath could not be fitted because of penile retraction. This patient was therefore established on urethral catheter drainage. Later, infection with Staphylococcus aureus around the receiver block necessitated its removal. In conclusion, spinal cord injury patients are at risk of developing pressure sores, wound infections, malfunction of implants, and the inability to use implants because of age-related changes, as well as running the risk of their implants becoming obsolete due to advances in medicine. Some surgical procedures such as dorsal rhizotomy are irreversible. Alternative treatments such as intermittent catheterisations may be less damaging than bladder stimulator in

  10. MR images of rupture and leakage of breast implants

    International Nuclear Information System (INIS)

    Fang Ling; Liu Pengcheng; Huang Rong; Hu Huaxin; Chen Zaizhong; Du Duanming; Liu Hanqiao; Feng Fei

    2002-01-01

    Objective: To investigate the diagnostic value of magnetic resonance imaging in detecting rupture and leakage of breast implants. Methods: Seventeen cases with breast implants were imaged by MR scanner. 1 normal silicone breast implant outside the body was scanned by MR as an consultative standard. MR images of silicone implants and polypropylene acyl amine implants were classified and analyzed. Results: In 7 cases, 12 single lumen silicone implants were intact, among them 8 were silicone gel-filled implants, 4 were physiological saline-filled implants. 2 physiological saline-filled implants ruptured, among them 1 belonged to intracapsular silicone implant rupture with subsided silicone gel capsule which presented as long T 1 signal and short T 2 signal on MR images; The other belonged to extracapsular silicone implant rapture with physiological saline granule outside breast on MR images. 20 breast implants in 10 cases were injected by polypropylene acyl amine, among them 2 breast implants were intact, 16 breast implants ruptured completely with pieces and nodes of long T 1 signal and long T 2 signal on MR images, 14 of 16 also presented polypropylene acyl amine granule outside breast; 2 breast implants splited inside with linguine sign. Conclusion: The magnetic resonance imaging can make clear the type and the seat of breast implants, the type of rupture of breast implants, and the distribution of leakage material. Therefore magnetic resonance imaging can be an effective guidance for clinical operation and can be an consultative standard for follow-up

  11. Metastatic spread from squamous cell carcinoma of the hypopharynx to the totally implantable venous access port insertion site: Case report and review of literature.

    Science.gov (United States)

    Mangla, Ankit; Agarwal, Nikki; Mullane, Michael Russell

    2017-12-01

    The totally implantable venous access port plays a crucial role in delivering chemotherapy in the outpatient setting. Here, we report the first case of a patient with hypopharyngeal tumor who developed chest wall metastasis over the totally implantable venous access port inserted in the internal jugular vein. Our patient, a 58-year-old man with a hypopharyngeal tumor presented with a lump over the totally implantable venous access port site. The port was removed and the lump was biopsied. The CT studies showed that the tumor had spread along the catheter from the hypopharynx to the chest wall. The pathology from the biopsy showed squamous cell carcinoma (SCC). The patient had poor performance status and opted for hospice care. We present a novel case of metastasis over the totally implantable venous access port implanted in a patient with a hypopharyngeal tumor. We also reviewed relevant literature comparing the data from percutaneous endoscopic gastrostomy (PEG) tube site metastasis with our patient and other similar case reports. © 2017 Wiley Periodicals, Inc.

  12. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  13. Prosthetic management of malpositioned implant using custom cast abutment

    Science.gov (United States)

    Chatterjee, Aishwarya; Ragher, Mallikarjuna; Patil, Sanket; Chatterjee, Debopriya; Dandekeri, Savita; Prabhu, Vishnu

    2015-01-01

    Two cases are reported with malpositioned implants. Both the implants were placed 6–7 months back. They had osseointegrated well with the surrounding bone. However, they presented severe facial inclination. Case I was restored with custom cast abutment with an auto polymerizing acrylic gingival veneer. Case II was restored with custom cast UCLA type plastic implant abutment. Ceramic was directly fired on the custom cast abutments. The dual treatment strategy resulted in functional and esthetic restorations despite facial malposition of the implants. PMID:26538957

  14. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  15. Ion implantation and bio-compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yoshiaki; Kusakabe, Masahiro [Sony Corp., Tokyo (Japan). Corporate Research Labs.; Iwaki, Masaya

    1992-07-01

    Surface modification of polymers by ion implantation has been carried out to control surface properties such as conductivity, wettability, blood and tissue compatibility. Ion implantation into silicone rubber, polystyrene and segmented polyurethane was performed at 150 keV with doses ranging from 1 x 10[sup 15] to 3 x 10[sup 17] ions/cm[sup 2] to improve bio-compatibility. The platelet accumulation on ion implanted silicone rubber decreased and non-thrombogenicity of ion implanted specimens were improved. The ion implanted polystyrene and segmented polyurethane have been found to exhibit remarkably higher adhesion and spreading of endothelial cells compared to the non-implanted case. It is concluded that ion implantation into polymers is effective in controlling their bio-compatibility. (author).

  16. The effect of oxygen on segregation-induced redistribution of rare-earth elements in silicon layers amorphized by ion implantation

    International Nuclear Information System (INIS)

    Aleksandrov, O. V.

    2006-01-01

    A model of segregation-induced redistribution of impurities of rare-earth elements during solid-phase epitaxial crystallization of silicon layers amorphized by ion implantation is developed. This model is based on the assumption that a transition layer with a high mobility of atoms is formed at the interphase boundary on the side of a-Si; the thickness of this layer is governed by the diffusion length of vacancies in a-Si. The Er concentration profiles in Si implanted with both erbium and oxygen ions are analyzed in the context of the model. It shown that, in the case of high doses of implantation of rare-earth ions, it is necessary to take into account the formation of R m clusters (m = 4), where R denotes the atom of a rare-earth element, whereas, if oxygen ions are also implanted, formation of the complexes RO n (n = 3-6) should be taken into account; these complexes affect the transition-layer thickness and segregation coefficient

  17. Management of peri-implant infections

    Directory of Open Access Journals (Sweden)

    K L Vandana

    2015-01-01

    Full Text Available The ever-increasing popularity of dental implants in recent years has been associated with the reported incidence of short-term and long-term complications such as peri-implant mucositis and peri-implantitis. Therapies proposed for treating peri-implantitis are based on the evidence available for the treatment of periodontitis, and are aimed at reducing the bacterial load within peri-implant pockets and decontaminating implant surfaces, and, in some cases, attempting afterward to bring about bone regeneration. The treatment of peri-implant infections comprises conservative (nonsurgical and surgical approaches. This paper reviews various treatment strategies used for the treatment of peri-implant diseases. There are many approaches suggested by various authors for the treatment of peri-implant diseases, but there is no “ideal peri-implant therapy” that has been described in the literature. There is no consensus regarding the treatment protocol as the studies conducted so far have had varying study designs, small sample sizes, and short follow-up periods.

  18. The predictors of dislodgement and outcomes of transcatheter closure of complex atrial septal defects in adolescents and adults

    Directory of Open Access Journals (Sweden)

    Wei-Chieh Lee

    2015-11-01

    Conclusion: Eroded and floppy IAS or aneurysm formation post ASO implantation and peri-procedure arrhythmia could predict ASO dislodgement in complex ASD closure. Transcatheter closure of ASDs under TEE guidance is feasible in complex cases.

  19. A novel implantation model for evaluation of bone healing response to dental implants: the goat iliac crest.

    NARCIS (Netherlands)

    Schouten, C.; Meijer, G.J.; Beucken, J.J.J.P van den; Spauwen, P.H.M.; Jansen, J.A.

    2010-01-01

    OBJECTIVES: Despite the availability of numerous animal models for testing the biological performance of dental and orthopedic implants, the selection of a suitable model is complex. This paper presents a new model for objective and standardized evaluation of bone responses to implants using the

  20. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    Science.gov (United States)

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  1. Soft and Firm Alloplastic Implants in Rhinoplasty: Why, When and How to Use Them: A Review of 311 Cases.

    Science.gov (United States)

    Fanous, Nabil; Tournas, Athanasios; Côté, Valérie; Ali, Yaseen; Berbari, Patricia; Fanous, Amanda; Campagna-Vaillancourt, Maude

    2017-04-01

    Modern rhinoplasty is not just a reduction procedure. An optimal nasal esthetic result occasionally requires augmenting the nasal tip, the dorsum or the lateral wall with autografts or alloplasts. A large number of nasal implant types have been reported in the medical literature. The goal of this article is to demystify the role and indications of nasal implants in rhinoplasty. As well, it offers both the novice and experienced nasal surgeon a basic, simplified and organized approach to the use of soft and firm nasal implants in rhinoplasty. This article presents the authors experience with 311 rhinoplasties using both soft and firm alloplastic implants. The indications for both types of alloplasts are discussed, the surgical technique detailed and the outcomes analyzed. A total of 311 nasal implant cases were reviewed. This series revealed a low incidence of postoperative infection (5.57% for soft implants and 0.1% for the firm ones). The revision rate was 2.7% for the soft implants group and 7.1% for the firm implants group. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  2. Implante orbital misto para reconstrução de cavidade anoftálmica: relato de caso Miscellaneous orbital implant for anophthalmic cavity reconstruction surgery: case report

    Directory of Open Access Journals (Sweden)

    Davi Araf

    2010-02-01

    moment. This case showed us that it is possible to use a more economic implant model with the same results of medpor (Porex®.

  3. First implantation of selective his bundle pacing in Colombia. Report of two cases

    International Nuclear Information System (INIS)

    Velasquez, Jorge E; Duque, Mauricio; Marin V, Jorge E; Aristizabal, Julian M; Medina, Luis E; Gonzalez, Edgardo; Duque, Laura; Uribe, William

    2010-01-01

    Pacing in the right ventricular apex is known to produce ventricular dysynchrony and patients often develop dilated cardiomyopathy. For this reason, a more physiological stimulation has been performed. With the recent technological development of electrodes for selective stimulation of the His bundle, we want to show the experience of this type of implantation in the first two cases made in the electrophysiology laboratory in Medellin.

  4. Candida and cardiovascular implantable electronic devices: a case of lead and native aortic valve endocarditis and literature review.

    Science.gov (United States)

    Glavis-Bloom, Justin; Vasher, Scott; Marmor, Meghan; Fine, Antonella B; Chan, Philip A; Tashima, Karen T; Lonks, John R; Kojic, Erna M

    2015-11-01

    Use of cardiovascular implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), has increased dramatically over the past two decades. Most CIED infections are caused by staphylococci. Fungal causes are rare and their prognosis is poor. To our knowledge, there has not been a previously reported case of multifocal Candida endocarditis involving both a native left-sided heart valve and a CIED lead. Here, we report the case of a 70-year-old patient who presented with nausea, vomiting, and generalised fatigue, and was found to have Candida glabrata endocarditis involving both a native aortic valve and right atrial ICD lead. We review the literature and summarise four additional cases of CIED-associated Candida endocarditis published from 2009 to 2014, updating a previously published review of cases prior to 2009. We additionally review treatment guidelines and discuss management of CIED-associated Candida endocarditis. © 2015 Blackwell Verlag GmbH.

  5. Trapping of deuterium in argon-implanted nickel

    International Nuclear Information System (INIS)

    Frank, R.C.; Rehn, L.E.; Baldo, P.

    1985-01-01

    Argon ions with energy 250 keV were implanted at fluences of 2 x 10 16 cm -2 at temperatures of 500, 250, and 21 0 C, in the specimen of relatively pure polycrystalline nickel. Deuterium was introduced into the surface and implanted regions by making the specimen the negative electrode of an electrolytic cell containing 1-N pure deuterated sulfuric acid. Deuterium trapped in the vacancy complexes of the implanted regions was analyzed as a function of temperature using the vacancy complexes of the implanted regions was analyzed as a function of temperature using the 2 H( 3 He, 1 H) 4 He nuclear reaction during an isochronal annealing process. The results indicate that the types of traps and trap densities found in the regions implanted at 21 and 250 0 C were essentially identical while the trap density found in the region implanted at 500 0 C was approximately 40% of that found in the other regions. Math model comparison with the experimental results suggests the existence of at least two types of traps in each region. Trap binding enthalpies used in the math model to fit the experimental data were slightly higher for the region implanted with argon at 500 0 C than for the regions implanted at the lower temperatures. TEM studies revealed the presence of small voids in the region implanted at 500 0 as well as dislocation loops similar to those found in the regions implanted at the lower temperatures. 20 references, 2 figures

  6. Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports.

    Science.gov (United States)

    Han, Ji-Deuk; Cho, Seong-Ho; Jang, Kuk-Won; Kim, Seong-Gwang; Kim, Jung-Han; Kim, Bok-Joo; Kim, Chul-Hun

    2017-08-01

    This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst.

  7. Simulation of the proton implantation process in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Faccinelli, Martin; Hadley, Peter [Graz University of Technology, Institute of Solid State Physics (Austria); Jelinek, Moriz; Wuebben, Thomas [Infineon Technologies Austria AG, Villach (Austria); Laven, Johannes G.; Schulze, Hans-Joachim [Infineon Technologies AG, Neubiberg (Germany)

    2016-12-15

    Proton implantation is one of many processes used to ad-just the electronic and mechanical properties of silicon. Though the process has been extensively studied, it is still not clear which exact defects are formed and what their concentration profiles are. In this article, a simulation method is presented, which provides a better understanding of the implantation process. The simulation takes into account the diffusion of mobile point defects and their reactions to defect complexes, as well as the dissociation of defect complexes. Concentration profiles for a set of defect complexes after an implantation at 400 keV and a dose of 5 x 10{sup 14} H{sup +}cm{sup -2} are presented. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Basic research on maxillofacial implants

    International Nuclear Information System (INIS)

    Matsui, Yoshiro

    2001-01-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  9. Basic research on maxillofacial implants

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Yoshiro [Showa Univ., Tokyo (Japan). School of Dentistry

    2001-11-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  10. Dual-ion implantation into GaAs

    International Nuclear Information System (INIS)

    Sealy, B.J.; Bell, E.C.; Surridge, R.K.; Stephens, K.G.; Ambridge, T.; Heckingbottom, R.

    1976-01-01

    A variety of dual implants have been carried out to test the theory of Ambridge and Heckingbottom (Ambridge, T. and Heckingbottom, R., 1973, Radiat. Effects, vol. 17, 31). After annealing at 700 0 C or 750 0 C a significant enhancement of electrical activity compared with single-ion implants has been obtained for (Ga + Se) and (Sn + Se) implants but the degree of enhancement is dose dependent. The results imply that the dual implantation process is more complex than predicted by the theory and the electrical activity measured seems to be dominated by residual, compensating damage. (author)

  11. Primary anaplastic large cell lymphoma of the breast arising in reconstruction mammoplasty capsule of saline filled breast implant after radical mastectomy for breast cancer: an unusual case presentation

    Directory of Open Access Journals (Sweden)

    Sur Monalisa

    2009-04-01

    Full Text Available Abstract Background Primary non-Hodgkin lymphoma (NHL of the breast represents 0.04–0.5% of malignant lesions of the breast and accounts for 1.7–2.2% of extra-nodal NHL. Most primary cases are of B-cell phenotype and only rare cases are of T-cell phenotype. Anaplastic large cell lymphoma (ALCL is a rare T-cell lymphoma typically seen in children and young adults with the breast being one of the least common locations. There are a total of eleven cases of primary ALCL of the breast described in the literature. Eight of these cases occurred in proximity to breast implants, four in relation to silicone breast implant and three in relation to saline filled breast implant with three out of the eight implant related cases having previous history of breast cancer treated surgically. Adjuvant postoperative chemotherapy is given in only one case. Secondary hematological malignancies after breast cancer chemotherapy have been reported in literature. However in contrast to acute myeloid leukemia (AML, the association between lymphoma and administration of chemotherapy has never been clearly demonstrated. Case Presentation In this report we present a case of primary ALCL of the breast arising in reconstruction mamoplasty capsule of saline filled breast implant after radical mastectomy for infiltrating ductal carcinoma followed by postoperative chemotherapy twelve years ago. Conclusion Primary ALK negative ALCL arising at the site of saline filled breast implant is rare. It is still unclear whether chemotherapy and breast implantation increases risk of secondary hematological malignancies significantly. However, it is important to be aware of these complications and need for careful pathologic examination of tissue removed for implant related complications to make the correct diagnosis for further patient management and treatment. It is important to be aware of this entity at this site as it can be easily misdiagnosed on histologic grounds and to exclude

  12. Amorphous clusters in Co implanted ZnO induced by boron pre-implantation

    Energy Technology Data Exchange (ETDEWEB)

    Potzger, K.; Shalimov, A.; Zhou, S.; Schmidt, H.; Mucklich, A.; Helm, M.; Fassbender, J.; Liberati, M.; Arenholz, E.

    2009-02-09

    We demonstrate the formation of superparamagnetic/ferromagnetic regions within ZnO(0001) single crystals sequently implanted with B and Co. While the pre-implantation with B plays a minor role for the electrical transport properties, its presence leads to the formation of amorphous phases. Moreover, B acts strongly reducing on the implanted Co. Thus, the origin of the ferromagnetic ordering in local clusters with large Co concentration is itinerant d-electrons as in the case of metallic Co. The metallic amorphous phases are non-detectable by common X-ray diffraction.

  13. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    Science.gov (United States)

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  14. Localized morphea after breast implant for breast cancer: A case report.

    Science.gov (United States)

    Moretti, A; Bianchi, F; Abbate, I V; Gherardi, G; Bonavita, M; Passoni, E; Nazzaro, G; Bramati, A; Dazzani, M C; Piva, S; Paternò, E; Frungillo, N; Farina, G; La Verde, N

    2018-03-01

    Early breast cancer follow-up guidelines for patients who underwent surgery suggest a regular and accurate clinical examination of the breast area, for an early identification of cutaneous or subcutaneous breast cancer relapse. Nonetheless, breast skin lesions arising in patients treated with mastectomy for breast cancer can be caused by several diseases. A series of diagnostic hypotheses should be considered, not only focusing on cutaneous metastasis, but also on dermatologic and systemic diseases. In February 2015, a 37-year-old patient underwent a right subcutaneous mastectomy for stage IIA breast cancer. Five months after beginning adjuvant chemotherapy, she noted hyperpigmentation and thickening of the skin on the right breast. Differential diagnosis included local relapse, skin infection, lymphoma, or primary cutaneous disease, and a skin biopsy was performed. The histopathologic specimen showed full-thickness sclerosis, with features of localized morphea. Therapy with clobetasol was prescribed, with progressive resolution of the thickness. The collaboration between many professionals in a multidisciplinary team (oncologist, dermatologist, plastic surgeon, and pathologist) was crucial to achieving the diagnosis. In the literature, some articles describe correlation between connective tissue diseases and silicone breast implants, but the pathogenetic mechanisms are unknown. We report a rare case of breast morphea after positioning a silicone implant in a patient who had undergone mastectomy. This clinical report represents an interesting model of multidisciplinary management of a patient with breast cancer who developed an uncommon dermatologic disease. Further studies are needed to clarify the association between silicone implants and breast morphea.

  15. Malpositioned Osseointegrated Implants Relocated with Segmental Osteotomies : A Retrospective Analysis of a Multicenter Case Series with a 1-to 15-Year Follow-Up

    NARCIS (Netherlands)

    Stacchi, Claudio; Chen, Stephen T.; Raghoebar, Gerry M.; Rosen, Daren; Poggio, Carlo E.; Ronda, Marco; Bacchini, Marco; Di Lenarda, Roberto

    2013-01-01

    Purpose: This multicenter case series evaluates retrospectively the clinical outcomes of malpositioned implants surgically relocated in a more convenient position by segmental osteotomies. Materials and Methods: Authors who published, on indexed journals or books, works about malpositioned implant

  16. The team approach to managing dental implant complications: strategies for treating peri-implantitis.

    Science.gov (United States)

    Rosen, Paul S

    2013-10-01

    Practitioners who are knowledgeable about the risk factors identified by the Consensus Report of the Sixth European Workshop on Periodontology and who are trained in techniques to eliminate or reduce them may be able to significantly improve long-term implant outcomes. A careful review of the literature suggests that this will include treatment planning, restoring a patient to periodontal heath before initiating care, appropriate implant selection, complete cement removal, and diligent recordkeeping that will track changes and enable early intervention should complications arise. In the case of the biologic complication of peri-implantitis, recent reports suggest that regenerative care may restore implants back to health.

  17. 3D Printing Guide Implant Placement: A Case Report

    Directory of Open Access Journals (Sweden)

    Vlahović Zoran

    2017-03-01

    Full Text Available Background: Cone Beam Computer Tomography (CBCT is representing a new concept of radiological diagnostics and its application occupies a special place in implantology. Today, preoperative planning, and quantitative and qualitative jaw bone analysis cannot be done without the use of these techniques. The latest in a series of achievements in this field is a method of making a guide for implant using a 3D printing technique. This way pre implantology planning reduces the chance of surgical complications to a minimum and allows installation of dental implants in the most optimal position for future prosthetic work. Aim: To show benefits of guide implantation in clinical practice.

  18. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  19. N-Acetyl-Cysteine as Effective and Safe Chelating Agent in Metal-on-Metal Hip-Implanted Patients: Two Cases

    Directory of Open Access Journals (Sweden)

    Andrea Giampreti

    2016-01-01

    Full Text Available Systemic toxicity associated with cobalt (Co and chromium (Cr containing metal hip alloy may result in neuropathy, cardiomyopathy, and hypothyroidism. However clinical management concerning chelating therapy is still debated in literature. Here are described two metal-on-metal hip-implanted patients in which N-acetyl-cysteine decreased elevated blood metal levels. A 67-year-old male who underwent Co/Cr hip implant in September 2009 referred to our Poison Control Centre for persisting elevated Co/Cr blood levels (from March 2012 to November 2014. After receiving oral high-dose N-acetyl-cysteine, Co/Cr blood concentrations dropped by 86% and 87% of the prechelation levels, respectively, and persisted at these latter concentrations during the following 6 months of follow-up. An 81-year-old female who underwent Co/Cr hip implant in January 2007 referred to our Centre for detection of high Co and Cr blood levels in June 2012. No hip revision was indicated. After a therapy with oral high-dose N-acetyl-cysteine Co/Cr blood concentrations decreased of 45% and 24% of the prechelation levels. Chelating agents reported in hip-implanted patients (EDTA, DMPS, and BAL are described in few cases. N-acetyl-cysteine may provide chelating sites for metals and in our cases reduced Co and Cr blood levels and resulted well tolerable.

  20. Artificial urinary sphincter implantation: an important component of complex surgery for urinary tract reconstruction in patients with refractory urinary incontinence.

    Science.gov (United States)

    Zhang, Fan; Liao, Limin

    2018-01-08

    We review our outcomes and experience of artificial urinary sphincter implantation for patients with refractory urinary incontinence from different causes. Between April 2002 and May 2017, a total of 32 patients (median age, 40.8 years) with urinary incontinence had undergone artificial urinary sphincter placement during urinary tract reconstruction. Eighteen patients (56.3%) were urethral injuries associated urinary incontinence, 9 (28.1%) had neurogenic urinary incontinence and 5 (15.6%) were post-prostatectomy incontinence. Necessary surgeries were conducted before artificial urinary sphincter placement as staged procedures, including urethral strictures incision, sphincterotomy, and augmentation cystoplasty. The mean follow-up time was 39 months. At the latest visit, 25 patients (78.1%) maintained the original artificial urinary sphincter. Four patients (12.5%) had artificial urinary sphincter revisions. Explantations were performed in three patients. Twenty-four patients were socially continent, leading to the overall success rate as 75%. The complication rate was 28.1%; including infections (n = 4), erosions (n = 4), and mechanical failure (n = 1). The impact of urinary incontinence on the quality of life measured by the visual analogue scale dropped from 7.0 ± 1.2 to 2.2 ± 1.5 (P urinary sphincter implantation in our center are unique, and the procedure is an effective treatment as a part of urinary tract reconstruction in complicated urinary incontinence cases with complex etiology.

  1. On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI

    Science.gov (United States)

    Córcoles, Juan; Zastrow, Earl; Kuster, Niels

    2017-06-01

    The increasing use of multiple radiofrequency (RF) transmit channels in magnetic resonance imaging (MRI) systems makes it necessary to rigorously assess the risk of RF-induced heating. This risk is especially aggravated with inclusions of medical implants within the body. The worst-case RF-heating scenario is achieved when the local tissue deposition in the at-risk region (generally in the vicinity of the implant electrodes) reaches its maximum value while MRI exposure is compliant with predefined general specific absorption rate (SAR) limits or power requirements. This work first reviews the common approach to estimate the worst-case RF-induced heating in multi-channel MRI environment, based on the maximization of the ratio of two Hermitian forms by solving a generalized eigenvalue problem. It is then shown that the common approach is not rigorous and may lead to an underestimation of the worst-case RF-heating scenario when there is a large number of RF transmit channels and there exist multiple SAR or power constraints to be satisfied. Finally, this work derives a rigorous SAR-based formulation to estimate a preferable worst-case scenario, which is solved by casting a semidefinite programming relaxation of this original non-convex problem, whose solution closely approximates the true worst-case including all SAR constraints. Numerical results for 2, 4, 8, 16, and 32 RF channels in a 3T-MRI volume coil for a patient with a deep-brain stimulator under a head imaging exposure are provided as illustrative examples.

  2. Ion implantation in compound semiconductors for high-performance electronic devices

    International Nuclear Information System (INIS)

    Zolper, J.C.; Baca, A.G.; Sherwin, M.E.; Klem, J.F.

    1996-01-01

    Advanced electronic devices based on compound semiconductors often make use of selective area ion implantation doping or isolation. The implantation processing becomes more complex as the device dimensions are reduced and more complex material systems are employed. The authors review several applications of ion implantation to high performance junction field effect transistors (JFETs) and heterostructure field effect transistors (HFETs) that are based on compound semiconductors, including: GaAs, AlGaAs, InGaP, and AlGaSb

  3. Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation.

    Science.gov (United States)

    Forlini, Cesare; Forlini, Matteo; Rejdak, Robert; Prokopiuk, Agata; Levkina, Oxana; Bratu, Adriana; Rossini, Paolo; Cagampang, Perfecto R; Cavallini, Gian Maria

    2013-03-01

    Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia. Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel. Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque. Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.

  4. Measuring case-mix complexity of tertiary care hospitals using DRGs.

    Science.gov (United States)

    Park, Hayoung; Shin, Youngsoo

    2004-02-01

    The objectives of the study were to develop a model that measures and evaluates case-mix complexity of tertiary care hospitals, and to examine the characteristics of such a model. Physician panels defined three classes of case complexity and assigned disease categories represented by Adjacent Diagnosis Related Groups (ADRGs) to one of three case complexity classes. Three types of scores, indicating proportions of inpatients in each case complexity class standardized by the proportions at the national level, were defined to measure the case-mix complexity of a hospital. Discharge information for about 10% of inpatient episodes at 85 hospitals with bed size larger than 400 and their input structure and research and education activity were used to evaluate the case-mix complexity model. Results show its power to predict hospitals with the expected functions of tertiary care hospitals, i.e. resource intensive care, expensive input structure, and high levels of research and education activities.

  5. ”Are CRT upgrade procedures more complex and associated with more complications than de novo CRT implantations?” A single centre experience

    NARCIS (Netherlands)

    Ter Horst, I. A H; Kuijpers, Y.; van t Sant, Jetske; Tuinenburg, A. E.; Cramer, M. J.; Meine, M.

    2016-01-01

    Objective The objective of the study was to examine whether cardiac resynchronisation therapy upgrade procedures are more complex and associated with more complications than de novo implantations. Method We retrospectively compared 134 upgrade procedures performed between 2006-2012 with a random,

  6. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.

    Science.gov (United States)

    Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku

    2012-01-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

  7. Electroencephalographic evoked pain response is suppressed by spinal cord stimulation in complex regional pain syndrome: a case report.

    Science.gov (United States)

    Hylands-White, Nicholas; Duarte, Rui V; Beeson, Paul; Mayhew, Stephen D; Raphael, Jon H

    2016-12-01

    Pain is a subjective response that limits assessment. The purpose of this case report was to explore how the objectivity of the electroencephalographic response to thermal stimuli would be affected by concurrent spinal cord stimulation. A patient had been implanted with a spinal cord stimulator for the management of complex regional pain syndrome of both hands for 8 years. Following ethical approval and written informed consent we induced thermal stimuli using the Medoc PATHWAY Pain & Sensory Evaluation System on the right hand of the patient with the spinal cord stimulator switched off and with the spinal cord stimulator switched on. The patient reported a clinically significant reduction in thermal induced pain using the numerical rating scale (71.4 % reduction) with spinal cord stimulator switched on. Analysis of electroencephalogram recordings indicated the occurrence of contact heat evoked potentials (N2-P2) with spinal cord stimulator off, but not with spinal cord stimulator on. This case report suggests that thermal pain can be reduced in complex regional pain syndrome patients with the use of spinal cord stimulation and offers objective validation of the reported outcomes with this treatment.

  8. Human implantation: the last barrier in assisted reproduction technologies?

    Science.gov (United States)

    Edwards, Robert G

    2006-12-01

    Implantation processes are highly complex involving the actions of numerous hormones, immunoglobulins, cytokines and other factors in the endometrium. They are also essential matters for the success of assisted reproduction. The nature of early embryonic development is of equal significance. It involves ovarian follicle growth, ovulation, fertilization and preimplantation growth. These processes are affected by imbalanced chromosomal constitutions or slow developmental periods. Post-implantation death is also a significant factor in cases of placental insufficiency or recurrent abortion. Clearly, many of these matters can significantly affect birth rates. This review is concerned primarily with the oocyte, the early embryo and its chromosomal anomalies, and the nature of factors involved in implantation. These are clearly among the most important features in determining successful embryonic and fetal growth. Successive sections cover the endocrine stimulation of follicle growth in mice and humans, growth of human embryos in vitro, their apposition and attachment to the uterus, factors involved in embryo attachment to uterine epithelium and later stages of implantation, and understanding the gene control of polarities and other aspects of preimplantation embryo differentiation. New aspects of knowledge include the use of human oocyte maturation in vitro as an approach to simpler forms of IVF, and new concepts in developmental genetics.

  9. PIP breast implants: rupture rate and correlation with breast cancer.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Cornacchia, I; Vincenti, L; Ranieri, V; Cirili, A; Rella, L; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.

  10. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  11. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  12. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  13. [The impact of dental implants

    NARCIS (Netherlands)

    Meijer, G.J.

    2013-01-01

    The importance of the introduction of dental implants can only be understood when the historical context is clarified. In the past, the main treatment carried out by dentists consisted of filling or, in unfortunate cases, removal of painful teeth. Only since the introduction of dental implants did

  14. Successful Rehabilitation of Partial Edentulous Maxilla and Mandible with New Type of Implants: Molecular Precision Implants

    Directory of Open Access Journals (Sweden)

    Matteo Danza

    2014-01-01

    Full Text Available The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant system. Excellent primary stability and high bone-implant contact are only minimal requirements for any type of implant procedure. In this paper we present a case report using a new type of implants. The new type of implants, due to its sophisticated control system of production, provides to the implantologist a safe and reliable implant, with a macromorphology designed to ensure a close contact with the surrounding bone.

  15. CT-guided radioactive 125I-seed implantation for the treatment of pancreatic carcinoma: a clinical observation of 19 cases

    International Nuclear Information System (INIS)

    Lu Jian; Zheng Yunfeng; Zhang Huan; Wang Zhongmin; Chen Kemin

    2010-01-01

    Objective: To explore the dynamic changes of serum tumor markers after CT-guided radioactive 125 I-seed implantation treatment in patients with pancreatic carcinoma and to assess the therapeutic effectiveness of 125 I-seed implantation. Methods: CT-guided radioactive 125 I-seed implantation was performed in 19 patients with unresectable advanced pancreatic cancer. Treatment planning system was used to reconstruct 3-dimentional images of the tumor, and the quantity and distribution of 125 I-seeds to be implanted were thus determined. Under CT guidance 125 I-seeds were embedded into pancreatic cancer. Before and after the 125 I-seed implantation the levels of serum tumor markers, including CEA, CA19-9 and CA50, were determined by using radioimmunoassay method. The clinical effects were observed and the therapeutic results were statistically analyzed. Results: The pain stared to be relieved 2 to 5 days after implantation. The total effective rate (CR + PR) at one and three months after treatment was 68.42% (13 /19) and 63.16% (12 /19) respectively. One month after 125 I-seed implantation, the levels of serum CEA, CA19-9 and CA50 were significantly different to that determined before implantation in all cases (P 125 I-seed implantation is a safe and effective interventional treatment for advanced pancreatic cancer with reliable short-term result and remarkable pain-relieving effect. Moreover, this therapy can significantly lower the levels of many serum tumor markers, which play some suggestive roles in evaluating the clinical curativeness. (authors)

  16. Study of the radiation effect in breast implants

    International Nuclear Information System (INIS)

    Moreno T, L. R.; Ramirez R, A.

    2013-01-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  17. Study of the radiation effect in breast implants

    Energy Technology Data Exchange (ETDEWEB)

    Moreno T, L. R.; Ramirez R, A., E-mail: lumor2000@yahoo.com.mx [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Departamento de Ciencias Basicas, Av. San Pablo No. 180, Col. Reynosa Tamaulipas, 02200 Mexico D. F. (Mexico)

    2013-10-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  18. [Custom-made implant for complex facial reconstruction: A case of total replacement of temporo-mandibular joint, zygomatic arch and malar bone].

    Science.gov (United States)

    Guillier, D; Moris, V; See, L-A; Girodon, M; Wajszczak, B-L; Zwetyenga, N

    2017-02-01

    Total prosthetic replacement of the temporo-mandibular joint (TMJ) has become a common procedure, but it is usually limited to the TMJ itself. We report about one case of complex prosthetic joint reconstruction extending to the neighbouring bony structures. A 57-year-old patient, operated several times for a cranio-facial fibrous dysplasia, presented with a recurring TMJ ankylosis and a complexe latero-facial bone loss on the right side. We performed a reconstruction procedure including the TMJ, the zygomatic arch and the malar bone by mean of custom made composite prosthesis (chrome-cobalt-molybdenum-titanium and polyethylene). Five years postoperatively, mouth opening, nutrition, pain and oral hygiene were significantly improved. Nowadays technical possibilities allow for complex facial alloplastic reconstructions with good medium term results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Stability of percutaneously implanted markers for lung stereotactic radiotherapy

    DEFF Research Database (Denmark)

    Persson, Gitte Bjørnsen Fredberg; Josipovic, Mirjana; Von Der Recke, Peter

    2013-01-01

    The purpose of this study was to evaluate the stability of complex markers implanted into lung tumors throughout a course of stereotactic body radiotherapy (SBRT). Fifteen patients referred for lung SBRT were prospectively included. Radio-opaque markers were implanted percutaneously, guided...... mm in one or more registrations throughout the SBRT course. This is the first study to evaluate stability of complex markers implanted percutaneously into lung tumors for image guidance in SBRT. We conclude that the observed stability of marker position within the tumor indicates that complex markers...... can be used as surrogates for tumor position during a short course of SBRT as long as the uncertainties related to their position within the tumor are incorporated into the planning target volume....

  20. Skin lesions over the pocket area that may mimic cardiac implantable electronic device infection: A case series.

    Science.gov (United States)

    Korantzopoulos, Panagiotis; Plakoutsi, Sofia; Florou, Elizabeth; Bechlioulis, Aris

    2018-05-21

    The early and correct diagnosis of cardiac implantable electronic device (CIED) infections is critical given that early aggressive treatment with complete removal of the system along with antimicrobial therapy dramatically improves outcomes. Pocket infection manifested by local signs of inflammation is the most common form of CIED infections. Conditions mimicking pocket infection have been described in the literature. These include various types of malignancy and rarely allergic reactions/contact dermatitis to pacemaker compounds. We aimed to describe skin lesions and disorders over the pocket area that mimic CIED infection. We present a series of 5 cases with skin lesions that mimic pocket infection. We document these cases with corresponding photographs. Most of them have not been described in this setting. We report the following cases of conditions that proved not to be CIED infection: One case of superficial cellulitis, one case of herpes zoster over the pocket area, one case of spontaneous bruising over the pocket a long time after implantation in a patient taking oral anticoagulation, and 2 cases of contact dermatitis due to prolonged postoperative application of povidone iodine. All cases had favorable outcome after conservative treatment and no CIED infection was developed during follow-up. Clinicians should be aware of rare conditions that mimic CIED infection. Incorrect diagnosis of these disorders may falsely lead to CIED extraction. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. Defect-impurity interactions in ion-implanted metals

    International Nuclear Information System (INIS)

    Turos, A.

    1986-01-01

    An overview of defect-impurity interactions in metals is presented. When point defects become mobile they migrate towards the sinks and on the way can be captured by impurity atoms forming stable associations so-called complexes. In some metallic systems complexes can also be formed athermally during ion implantation by trapping point defects already in the collision cascade. An association of a point defect with an impurity atom leads to its displacement from the lattice site. The structure and stability of complexes are strongly temperature dependent. With increasing temperature they dissociate or grow by multiple defect trapping. The appearance of freely migrating point defects at elevated temperatures, due to ion bombardment or thermal annealing, causes via coupling with defect fluxes, important impurity redistribution. Because of the sensitivity of many metal-in-metal implanted systems to radiation damage the understanding of this processes is essential for a proper interpretation of the lattice occupancy measurements and the optimization of implantation conditions. (author)

  2. Femtosecond laser-assisted cataract surgery and implantable miniature telescope

    Directory of Open Access Journals (Sweden)

    Randal Pham

    2017-09-01

    Conclusions and importance: To our knowledge and confirmed by the manufacturer of the implantable miniature telescope this is the first case ever reported of a patient who has undergone femtosecond laser cataract surgery with corneal astigmatism correction and implantation of the implantable miniature telescope. This is also the first case report of the preoperative use of microperimetry and visual electrophysiology to evaluate a patient's postoperative potential visual acuity. The success of the procedure illustrated the importance of meticulous preoperative planning, the combined use of state-of-the-art technologies and the seamless teamwork in order to achieve the best clinical outcome for patients who undergo implantation of the implantable miniature telescope.

  3. Zygoma implants in oral rehabilitation: A review of 28 cases.

    Science.gov (United States)

    Agbara, Rowland; Goetze, Elizabeth; Koch, Felix; Wagner, Wilfred

    2017-01-01

    The functional and esthetic rehabilitation of patients with atrophic maxilla or posterior maxillary defect is often challenging. The aim of this study was to determine patient demographics, indications, success rate, and complications following the use of zygoma implants. All patients who had zygoma implant placement in our clinic between 1998 and 2013 were retrospectively assessed for implant outcome. Data were analyzed using Statistical Package for the Social Sciences (SPSS) version 16 and Microsoft Excel 2007 test for significance (ρ) using Pearson's Chi-square (χ 2 ) set at 0.05. A total of 28 patients consisting of 22 females (78.6%) and 6 males (21.4%) were treated, and their age ranged from 41 years to 83 years with a mean age of 60.3 ± 10.6 years. The main indication for zygoma implant placement was atrophic maxilla 12 (42.9%). In the prosthetic rehabilitation of the patients, 2 had epithetic prostheses, and 2 had obturators while 18 patients had conventional removable dental prostheses. Four patients (14.3%) had perimplantitis and one implant was accidentally placed into the maxillary sinus. A cumulative success rate of 88.1% was obtained from this retrospective analysis. A cumulative success rate of 88.1% reported in this study is lower than the reports from other studies. The difference in success rates may be related to different criteria for assessment of zygoma implant success and to the difference in inclusion criteria and follow-up period.

  4. Treatment planning: implant-supported partial overdentures.

    Science.gov (United States)

    Chee, Winston W L

    2005-04-01

    When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the

  5. Implantation doping of GaN

    International Nuclear Information System (INIS)

    Zolper, J.C.

    1996-01-01

    Ion implantation has played an enabling role in the realization of many high performance photonic and electronic devices in mature semiconductor materials systems such as Si and GaAs. This can also be expected to be the case in III-Nitride based devices as the material quality continues to improve. This paper reviews the progress in ion implantation processing of the III-Nitride materials, namely, GaN, AlN, InN and their alloys. Details are presented of the successful demonstrations of implant isolation as well as n- and p-type implantation doping of GaN. Implant doping has required activation annealing at temperatures in excess of 1,000 C. The nature of the implantation induced damage and its response to annealing is addressed using Rutherford Backscattering. Finally, results are given for the first demonstration of a GaN device fabricated using ion implantation doping, a GaN junction field effect transistor (JFET)

  6. Experimental research of covered stent implanted in canine hepatic artery

    International Nuclear Information System (INIS)

    Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde

    2007-01-01

    Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)

  7. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  8. Transition from failing dentition to full-arch fixed implant-supported prosthesis with a staged approach using removable partial dentures: a case series.

    Science.gov (United States)

    Cortes, Arthur Rodriguez Gonzalez; Cortes, Djalma Nogueira; No-Cortes, Juliana; Arita, Emiko Saito

    2014-06-01

    The present retrospective case series is aimed at evaluating a staged approach using a removable partial denture (RPD) as an interim prosthesis in treatment to correct a failing dentition until such time as a full-arch fixed implant-supported prosthesis may be inserted. Eight patients, who had undergone maxillary full-arch rehabilitation with dental implants due to poor prognosis of their dentitions, were analyzed. All treatment included initial periodontal therapy and a strategic order of extraction of hopeless teeth. An RPD supported by selected teeth rehabilitated the compromised arch during implant osseointegration. These remaining teeth were extracted prior to definitive prosthesis delivery. Advantages and drawbacks of this technique were also recorded for the cases presented. Among the advantages provided by the staged approach are simplicity of fabrication, low cost, and ease of insertion. Additionally, RPD tooth support prevented contact between the interim prosthesis and healing abutments, promoting implant osseointegration. The main drawbacks were interference with speech and limited esthetic results. Implant survival rate was 100% within a follow-up of at least 1 year. The use of RPDs as interim prostheses allowed for the accomplishment of the analyzed rehabilitation treatments. It is a simple treatment alternative for patients with a low smile line. © 2013 by the American College of Prosthodontists.

  9. Sirviendo a los estudiantes sordos que tienen Los implantes cocleares. Hoja de consejos de PEPNet (Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet)

    Science.gov (United States)

    Clark, Catherine

    2010-01-01

    This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…

  10. Immediate provisionalization of immediate implants in the esthetic zone: a prospective case series evaluating implant survival, esthetics, and bone maintenance.

    Science.gov (United States)

    Levin, Barry P; Wilk, Brian L

    2013-05-01

    This prospective study evaluates immediately placed and immediately provisionalized implants in the esthetic zone. All implants were TiO2-blasted, fluoride-modified, grade 4 titanium, with a coronal microthread design. Bone grafting and guided bone regeneration (GBR) was performed at all sites, and screw-retained temporary restorations were delivered on the day of surgery. All of the provisional crown(s) were out of occlusal function and remained in place for at least 8 weeks prior to initiation of definitive restorative therapy. Bone maintenance (BM) was considered successful if radiographs demonstrated proximal bone levels even or coronal to the implant platform. Of the 29 implants placed, 25 (86 percent) achieved bone maintenance at least 12 months post-loading with the final restorations. This study was considered successful, with 100 percent implant survival after at least 1 year loading of the final restoration, and 100 percent of patients were satisfied with the esthetics of their implant treatment.

  11. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    Directory of Open Access Journals (Sweden)

    Huang Y

    2016-10-01

    Full Text Available Yu-Hui Huang,1,2 Rosemary Seelaus,1,2 Linping Zhao,1,2 Pravin K Patel,1,2 Mimis Cohen1,2 1The Craniofacial Center, Department of Surgery, Division of Plastic & Reconstructive Surgery, University of Illinois Hospital & Health Sciences System, 2University of Illinois College of Medicine at Chicago, Chicago, IL, USA Abstract: Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. Keywords: computer-assisted surgery, virtual surgical planning (VSP, 3D printing, orbital prosthetic reconstruction, craniofacial implants

  12. Electrical properties and dielectric spectroscopy of Ar{sup +} implanted polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Chawla, Mahak, E-mail: mahak.chawla@gmail.com; Shekhawat, Nidhi; Aggarwal, Sanjeev; Sharma, Annu [Department of Physics, Kurukshetra University, Kurukshetra - 136119 (India); Nair, K. G. M. [Consultant, UGC-DAE Consortium for Scientific Research, Kalpakkam Node, Kokilamedu-603104, Tamilnadu (India)

    2015-05-15

    The aim of the present paper is to study the effect of argon ion implantation on electrical and dielectric properties of polycarbonate. Specimens were implanted with 130 keV Ar{sup +} ions in the fluence ranging from 1×10{sup 14} to 1×10{sup 16} ions cm{sup −2}. The beam current used was ∼0.40 µA cm{sup −2}. The electrical conduction behaviour of virgin and Ar{sup +} implanted polycarbonate specimens have been studied through current-voltage (I-V characteristic) measurements. It has been observed that after implantation conductivity increases with increasing ion fluence. The dielectric spectroscopy of these specimens has been done in the frequency range of 100 kHz-100 MHz. Relaxation processes were studied by Cole-Cole plot of complex permittivity (real part of complex permittivity, ε′ vs. imaginary part of complex permittivity, ε″). The Cole-Cole plots have also been used to determine static dielectric constant (ε{sub s}), optical dielectric constant (ε{sub ∞}), spreading factor (α), average relaxation time (τ{sub 0}) and molecular relaxation time (τ). The dielectric behaviour has been found to be significantly affected due to Ar{sup +} implantation. The possible correlation between this behaviour and the changes induced by the implantation has been discussed.

  13. Immediate implants in extraction sockets with periapical lesions: an illustrated review

    Directory of Open Access Journals (Sweden)

    Arthur B. Novaes Jr.

    2013-10-01

    Full Text Available Aim Immediate implantation has gained great attention since first proposed. Immediate implants in replacement of teeth with periapical lesion is, to date, an issue of discussion. The aim of this study is to perform an illustrated literature review of immediate implants in sockets exhibiting previous periapical lesions.Materials and methods A search on medline/EMBASE database was done for the literature review which is presented together with two case reports illustrating the state of the art of immediate implants on sockets with periapical lesions. Both cases are presented in areas with great aesthetic demands and a periapical lesion of considerable size. The two cases were conducted following strict granulation tissue removal and careful rinsing and pre-operative antibiotics, followed by good primary stability of the dental implant.Results and conclusion Both cases represented successes in aesthetics and function, describing a successful protocol for immediate implant installation in areas exhibiting periapical lesions.

  14. Prospective study on cranioplasty with individual carbon fiber reinforced polymer (CFRP) implants produced by means of stereolithography.

    Science.gov (United States)

    Wurm, Gabriele; Tomancok, Berndt; Holl, Kurt; Trenkler, Johannes

    2004-12-01

    The aim of this study was to evaluate the value of carbon fiber reinforced polymer (CFRP) cranial implants produced by means of 3-dimensional (3D) stereolithography (SL) and template modeling for reconstructions of complex or extensive cranial defects. A series of 41 cranioplasties with individual CFRP implants was performed in 37 patients between April 1996 and November 2002. Only patients with complex and/or large cranial defects were included, most of them having extended scarring or dural calcification and poor quality of the overlying soft-tissue cover after infection or multiple preceding operations. Involvement of frontal sinus, a known risk factor for complications after cranioplasty, was the case in 21 patients (51.2%). A computer-based 3D model of the skull with the bony defect was generated by means of stereolithography after acquisition, evaluation and transfer of the patient's helical computed tomography (CT) data. A wax template of the defect that was used to design the individual prosthesis-shape was invested in dental stone. Then, the cranial implant was fabricated out of CFRP by loosen mold. Reconstruction of defects measuring up to 17 x 9 cm was performed. The intra-operative fit of the implants was excellent in 36 (87.8%), good in 1 (2.4%), and fair in 4 (9.8%) of the cases. Problems of implant fit occurred because of extended scarring and poor quality of soft-tissue cover. Adverse reactions were observed in 5 patients (1 subdural, 1 subcutaneous hematoma, 2 infections, 1 allergic reaction). Excellent contours and a solid stable reconstruction have been maintained in 30 out of 35 remaining plates (mean follow-up 3.6 years). No adverse effects concerning postoperative imaging, the accuracy of electroencephalograms and radiation therapy have been observed. The authors believe that this relatively new technique represents an advance in the management of complex and large cranial defects, but seems less suitable for simple defects because of cost

  15. Ion Implantation of Calcium and Zinc in Magnesium for Biodegradable Implant Applications

    Directory of Open Access Journals (Sweden)

    Sahadev Somasundaram

    2018-01-01

    Full Text Available In this study, magnesium was implanted with calcium-ion and zinc-ion at fluences of 1015, 1016, and 1017 ion·cm−2, and its in vitro degradation behaviour was evaluated using electrochemical techniques in simulated body fluid (SBF. Rutherford backscattering spectrometry (RBS revealed that the implanted ions formed layers within the passive magnesium-oxide/hydroxide layers. Electrochemical impedance spectroscopy (EIS results demonstrated that calcium-ion implantation at a fluence of 1015 ions·cm−2 increased the polarisation resistance by 24%, but higher fluences showed no appreciable improvement. In the case of zinc-ion implantation, increase in the fluence decreased the polarisation resistance. A fluence of 1017 ion·cm−2 decreased the polarisation resistance by 65%, and fluences of 1015 and 1016 showed only marginal effect. Similarly, potentiodynamic polarisation results also suggested that low fluence of calcium-ion decreased the degradation rate by 38% and high fluence of zinc-ion increased the degradation rate by 61%. All the post-polarized ion-implanted samples and the bare metal revealed phosphate and carbonate formation. However, the improved degradative behaviour in calcium-ion implanted samples can be due to a relatively better passivation, whereas the reduction in degradation resistance in zinc-ion implanted samples can be attributed to the micro-galvanic effect.

  16. CEMS of Sb+ implanted stainless steels

    International Nuclear Information System (INIS)

    Roy-Poulsen, H.; Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Hayashi, H.

    1986-01-01

    Martensitic transformations have been analyzed in a series of antimony implanted austenitic stainless steels using CEMS. The implanted samples contain about 70 vol% martensite, which is considerably more than can be formed conventionally by plastic deformation of cooling below the martensite start temperature. CEM spectra from implantation induced martensite and from martensite formed in conventional processes are virtually identical. In both cases the hyperfine field is ∼ 25T. (Auth.)

  17. CEMS of Sb+ implanted stainless steels

    International Nuclear Information System (INIS)

    Roy-Poulsen, H.; Copenhagen Univ.; Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Hayashi, H.

    1985-01-01

    Martensitic transformations have been analyzed in a series of antimony implanted austenitic stainless steels using CEMS. The implanted samples contain about 70 vol% martensite, which is considerably more than can be formed conventionally by plastic deformation or cooling below the martensite start temperature. CEM spectra from implantation induced martensite and from martensite formed in conventional processes are virtually identical. In both cases the hyperfine field is ∝25 T. (orig.)

  18. Infected Complex Odontoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Shanthala Damodar

    2015-06-01

    Full Text Available Odontoma represent a hamartomatous malformation. They are usually asymptomatic and are diagnosed on routine radiological examination. Infection of an odontome is very uncommon. Few cases of infected odontoma are reported in the literature. We report a special case of infected complex odontoma and perforation of the cheeks with a tooth impacted upon along with computed tomographic (CT image. Thus, making the present case unusual. [Cukurova Med J 2015; 40(2.000: 379-383

  19. Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: a case report

    Directory of Open Access Journals (Sweden)

    Hennessey Hooman

    2009-11-01

    Full Text Available Abstract Introduction In liver stereotactic body radiotherapy, reduction of normal tissue irradiation requires daily image guidance. This is typically accomplished by imaging a surrogate to the tumor. The surrogate is often an implanted metal fiducial marker. There are few reports addressing the specific risks of hepatic fiducial marker implantation. These risks are assumed to be similar to percutaneous liver biopsies which are associated with a 1-4% complication rate - almost always pain or bleeding. To the best of our knowledge, we present the first case of such a fiducial marker migrating to the heart. Case presentation An 81-year-old Caucasian man (5 years post-gastrectomy for a gastric adenocarcinoma was referred post-second line palliative chemotherapy for radiotherapy of an isolated liver metastasis. It was decided to proceed with treatment and platinum fiducials were chosen for radiation targeting. Under local anesthesia, three Nester embolization coils (Cook Medical Inc., Bloomington, IN, USA were implanted under computed tomography guidance. Before the placement of each coil, the location of the tip of the delivery needle was confirmed by computed tomography imaging. During the procedure, the third coil unexpectedly migrated through the hepatic vein to the inferior vena cava and lodged at the junction of the vena cava and the right atrium. The patient remained asymptomatic. He was immediately referred to angiography for extraction of the coil. Using fluoroscopic guidance, an EN Snare Retrieval System (Hatch Medical L.L.C., Snellville, GA, USA was introduced through a jugular catheter; it successfully grasped the coil and the coil was removed. The patient was kept overnight for observation and no immediate or delayed complications were encountered due to the migration or retrieval of the coil. He subsequently went on to be treated using the remaining fiducials. Conclusion Implanted fiducial markers are increasingly used for stereotactic

  20. Repair of olecranon fractures using fiberWire without metallic implants: report of two cases

    Directory of Open Access Journals (Sweden)

    Okawa Atsushi

    2010-10-01

    Full Text Available Abstract Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided.

  1. Repair of olecranon fractures using fiberWire without metallic implants: report of two cases.

    Science.gov (United States)

    Nimura, Akimoto; Nakagawa, Teruhiko; Wakabayashi, Yoshiaki; Sekiya, Ichiro; Okawa, Atsushi; Muneta, Takeshi

    2010-10-12

    Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided.

  2. Actinobacillus actinamycetemcomitans-associated peri-implantitis in an edentulous patient - A case report

    NARCIS (Netherlands)

    van Winkelhoff, AJ; Wolf, JWA

    Background: Peri-implantitis is a risk factor for implant loss. Late bacterial infection of the peri-implant tissues and loss of alveolar bone in edentulous patients is caused by commensal oral anaerobic bacteria. In partially edentulous patients, Porphyromonas gingivalis and occasionally

  3. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  4. Carbon and metal-carbon implantations into tool steels for improved tribological performance

    Science.gov (United States)

    Hirvonen, J.-P.; Harskamp, F.; Torri, P.; Willers, H.; Fusari, A.; Gibson, N.; Haupt, J.

    1997-05-01

    The high-fluence implantation of carbon and dual implantations of metal-metalloid pairs into steels with different microstructures are briefly reviewed. A previously unexamined system, the implantation of Si and C into two kinds of tool steels, M3 and D2, have been studied in terms of microstructure and tribological performance. In both cases ion implantation transfers a surface into an amorphous layer. However, the tribological behavior of these two materials differs remarkably: in the case of ion-implanted M3 a reduction of wear in a steel pin is observed even at high pin loads, whereas in the case of ion-implanted D2 the beneficial effects of ion implantation were limited to the lowest pin load. The importance of an initial phase at the onset of sliding is emphasized and a number of peculiarities observed in ion-implanted M3 steel are discussed.

  5. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    Science.gov (United States)

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  6. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  7. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    Science.gov (United States)

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  8. Additive manufacturing technologies of porous metal implants

    Directory of Open Access Journals (Sweden)

    Yang Quanzhan

    2014-06-01

    Full Text Available Biomedical metal materials with good corrosion resistance and mechanical properties are widely used in orthopedic surgery and dental implant materials, but they can easily cause stress shielding due to the significant difference in elastic modulus between the implant and human bones. The elastic modulus of porous metals is lower than that of dense metals. Therefore, it is possible to adjust the pore parameters to make the elastic modulus of porous metals match or be comparable with that of the bone tissue. At the same time, the open porous metals with pores connected to each other could provide the structural condition for bone ingrowth, which is helpful in strengthening the biological combination of bone tissue with the implants. Therefore, the preparation technologies of porous metal implants and related research have been drawing more and more attention due to the excellent features of porous metals. Selective laser melting (SLM and electron beam melting technology (EBM are important research fields of additive manufacturing. They have the advantages of directly forming arbitrarily complex shaped metal parts which are suitable for the preparation of porous metal implants with complex shape and fine structure. As new manufacturing technologies, the applications of SLM and EBM for porous metal implants have just begun. This paper aims to understand the technology status of SLM and EBM, the research progress of porous metal implants preparation by using SLM and EBM, and the biological compatibility of the materials, individual design and manufacturing requirements. The existing problems and future research directions for porous metal implants prepared by SLM and EBM methods are discussed in the last paragraph.

  9. Intra-Oral traumatic implantation: A case report | Bankole | West ...

    African Journals Online (AJOL)

    Key words: Trauma, Implantation, Oral cavity, Foreign body. Résumé Il s'agit d'un cas d'implantation traumatique d'un fragment d'un stylo à bille cassé dans la région ptérygomandibulaire d'un patient âgé de 13 ans. Enlèvement de la tige du stylo était opéré à travers la dissection émoussée et une manipulation attentive ...

  10. [Cochlear implant in patients with congenital malformation of inner ear].

    Science.gov (United States)

    Han, Dong-yi; Wu, Wen-ming; Xi, Xin; Huang, De-liang; Yang, Wei-yan

    2004-02-01

    To study surgical difficulty and key of the cochlear implant in patients with congenital malformation of inner ear. The cochlear implantations were performed in our department from Jan. 2001 to Apr. 2003 for 18 patients with the malformation of inner ear. In this series, there were 11 cases of large vestibular aqueduct syndrome (LVAS), 3 cases of Waardenberg syndrome, 3 cases of Mondini malformation, and 1 case of Usher syndrome. All 18 patients accepted the Nucleus 24-channel cochlear implantations, including Nucleus straight electrode in 13 cases but Contour implantation in 5 cases of LVAS. During operations, leakage of perilymph but not cerebrospinal fluid (CSF) from the open of scala tympani occurred in 11 cases of LVAS, however, the electrode was inserted successfully. The abnormalities of round window occurred in one of 3 cases of Waardenberg syndrome and 3 cases of Mondini malformation, respectively. The cochlear implant could be conducted successfully for the LVAS, and the postoperative effect was same as the ones for the deafness persons with normal development of inner ear. However, for the patients with Mondini syndrome and common cavity, it is important to accurately assess the extent of abnormalities in the inner ear and accompanied malformation before operation, and to evaluate the full extent of difficulties of the operation in order to minimize the risk of CSF leakage and meningitis.

  11. Relation between bruxism and dental implants

    OpenAIRE

    TORCATO,Leonardo Bueno; ZUIM,Paulo Renato Junqueira; BRANDINI,Daniela Atili; FALCÓN-ANTENUCCI,Rosse Mary

    2014-01-01

    OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review.METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medlinedatabases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled tr...

  12. Unusually large erupted complex odontoma: A rare case report

    Energy Technology Data Exchange (ETDEWEB)

    Bagewadi, Shivanand B.; Kukreja, Rahul; Suma, Gundareddy N.; Yadav, Bhawn; Sharma, Havi [Dept. of Oral Medicine and Radiology, ITS Centre for Dental Studies and Research, Murad Nagar (India)

    2015-03-15

    Odontomas are nonaggressive, hamartomatous developmental malformations composed of mature tooth substances and may be compound or complex depending on the extent of morphodifferentiation or on their resemblance to normal teeth. Among them, complex odontomas are relatively rare tumors. They are usually asymptomatic in nature. Occasionally, these tumors become large, causing bone expansion followed by facial asymmetry. Odontoma eruptions are uncommon, and thus far, very few cases of erupted complex odontomas have been reported in the literature. Here, we report the case of an unusually large, painless, complex odontoma located in the right posterior mandible.

  13. Oral Effects and Early Implant Survival Results After Imatinib Discontinuation Therapy for Chronic Myelogenous Leukemia: A Case Report.

    Science.gov (United States)

    Dixon, Douglas R; Yassin, Alaa

    2017-08-01

    Little is known regarding the success, failure, or complication rates of advanced implant procedures in patients after discontinuation therapy of long-term medications for the treatment of chronic myelogenous leukemia (CML). This case report presents initial results of a case involving implant placement in the mandible and maxilla as well as reduction of palatal oral pigmentation in a patient discontinuing long-term tyrosine kinase inhibitor (TKI) therapy for CML. A 57-year-old male was referred to the Department of Periodontics, University of Washington, Seattle, Washington, for an assessment of edentulous areas (tooth sites #3 and #14) and failing tooth #19. Previous medical treatment included oral administration (>10 years) of TKI for the treatment of CML. Systemic complications arising from long-term TKI therapy were treated with discontinuation of this medication. Concurrently, after multispecialty dental and medical consultation, extraction of tooth #19 with immediate implant placement and bilateral sinus augmentation with simultaneous implant placement were successfully performed during three separate surgical appointments. Additionally, marked reduction of oral palatal pigmentation was observed during the surgical and restorative phases after TKI discontinuation. Patients with a history of long-term TKIs for CML are at risk for developing complications that result in discontinuation of therapy. Long-term benefits of therapy may allow these patients to enjoy remission with an extended and improved quality of life. Patients undergoing discontinuation therapy may seek dental care. Therefore, dental providers need to understand these systemic interactions and, with multispecialty consultation, may help effectively treat these individuals.

  14. Consecutive case series of 244 age-related macular degeneration patients undergoing implantation with an extended macular vision IOL.

    Science.gov (United States)

    Qureshi, Muhammad A; Robbie, Scott J; Hengerer, Fritz H; Auffarth, Gerd U; Conrad-Hengerer, Ina; Artal, Pablo

    2018-03-01

    To determine safety and visual outcomes in eyes with age-related macular degeneration (AMD) implanted with a novel intraocular lens (IOL) that delivers an optimized retinal image to all macular areas within 10 degrees of retinal eccentricity. This was a consecutive case series of 244 eyes with dry/stable wet AMD and logMAR visual acuity ≥0.3 implanted with iolAMD Eyemax mono TM (London Eye Hospital Pharma), a single-piece, injectable, hydrophobic acrylic IOL sited in the capsular bag. Primary outcome was safety. Secondary outcomes were changes in corrected distance visual acuity (CDVA) and corrected near visual acuity (CNVA) (logMAR). Mean age at surgery was 80 years. Mean duration of follow-up was 3 months (range 1-16 months). No eyes had worsening of CDVA. Frequency of perioperative complications was equivalent to standard IOL implantation. Postoperative refractive outcomes were within ±1 D of the target refraction in 88% of cases. Mean preoperative CDVA improved from 1.06 to 0.71 postoperatively (mean of differences -0.35; 95% confidence interval [CI] -0.3886 to -0.3223; p<0.0001), equating to an approximate Early Treatment Diabetic Retinopathy Study gain of 18 letters. Mean preoperative CNVA (N-point; logMAR conversion) improved from 1.36 to 0.88 postoperatively (mean of differences -0.48; 95% CI -0.53 to -0.44; p<0.0001). This novel IOL appears safe in the short to medium term. Improvements in postoperative CDVA and CNVA exceed those observed with standard implants.

  15. Level of emotion comprehension in children with mid to long term cochlear implant use: How basic and more complex emotion recognition relates to language and age at implantation.

    Science.gov (United States)

    Mancini, Patrizia; Giallini, Ilaria; Prosperini, Luca; D'alessandro, Hilal Dincer; Guerzoni, Letizia; Murri, Alessandra; Cuda, Domenico; Ruoppolo, Giovanni; De Vincentiis, Marco; Nicastri, Maria

    2016-08-01

    The current study was designed with three main aims: To document the level of emotional comprehension skills, from basic to more complex ones, reached by a wide sample of cochlear implant (CI) deaf children with at least 36 months of device use; To investigate subjective and audiological factors that can affect their emotional development; To identify, if present, a "critical age", in which early intervention might positively affect adequate emotional competence development. This is an observational cohort study. Children with congenital severe/profound deafness were selected based on: aged by 4-11 years, minimum of 36 months of CI use, Italian as the primary language in the family; normal cognitive level and absence of associated disorders or socio-economic difficulties. Audiological characteristics and language development were assessed throughout standardized tests, to measure speech perception in quiet, lexical comprehension and production. The development of emotions' understanding was assessed using the Test of Emotion Comprehension (TEC) of Pons and Harris, a hierarchical developmental model, where emotion comprehension is organized in 3 Stages (external, mental and reflective). Statistical analysis was accomplished via the Spearman Rank Correlation Coefficient, to study the relationship between the personal and audiological characteristics; a multivariate linear regression analysis was carried out to find which variables were better associated with the standardized TEC values; a chi-squared test with Yate's continuity correction and Mann-Whitney U test were used to account for differences between continuous variables and proportions. 72 children (40 females, 32 males) with a mean age of 8.1 years were included. At TEC score, 57 children showed normal range performances (79.17% of recipients) and 15 fell below average (20.83% of recipients). The 16.63% of older subjects (range of age 8-12 years) didn't master the Stage 3 (reflective), which is normally

  16. Rehabilitation of Avulsed Teeth in Fractured Jaws via Bone Grafting and Implant Placement: Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Anshul Jain

    2016-01-01

    Full Text Available The maxillofacial region is one of the most injury-prone areas during road traffic accidents, personal violence, falls and sports. Maxillofacial trauma can lead to breakage or avulsion of upper anterior teeth, which may cause significant aesthetic and functional problems. There are many treatment options available for rehabilitation including removable partial dentures, fixed partial dentures, crown and bridges and implant-supported prostheses.Herein, two cases are presented where implant placement was done for upper anterior teeth, which were traumatized or avulsed following maxillofacial trauma. Both patients demonstrated a history of maxillofacial trauma and had undergone open reduction and internal fixation. The first patient had a severe maxillary alveolar defect treated via autogenous bone grafting and a six-month period was given for proper integration of the bone graft. The second patient was a smoker with very poor oral hygiene and a deep bite. Thus, implant placement was not initially justified.

  17. Managing peri-implant bone loss: current understanding.

    Science.gov (United States)

    Aljateeli, Manar; Fu, Jia-Hui; Wang, Hom-Lay

    2012-05-01

    With the improved macro- and micro-designs, dental implants enjoy a high survival rate. However, peri-implant bone loss has recently emerged to be the focus of implant therapy. As such, researchers and clinicians are in need of finding predictable techniques to treat peri-implant bone loss and stop its progression. Literature search on the currently available treatment modalities was performed and a brief description of each modality was provided. Numerous techniques have been proposed and none has been shown to be superior and effective in managing peri-implant bone loss. This may be because of the complex of etiological factors acting on the implant-supported prosthesis hence the treatment approach has to be individually tailored. Due to the lack of high-level clinical evidence on the management of peri-implant bone loss, the authors, through a literature review, attempt to suggest a decision tree or guideline, based on sound periodontal surgical principles, to aid clinicians in managing peri-implantitis associated bone loss. © 2011 Wiley Periodicals, Inc.

  18. SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

    International Nuclear Information System (INIS)

    Sheu, R; Powers, A; McGee, H; Stock, R; Lo, Y

    2016-01-01

    Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

  19. SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

    Energy Technology Data Exchange (ETDEWEB)

    Sheu, R; Powers, A; McGee, H; Stock, R; Lo, Y [Mount Sinai Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

  20. Expanding TAVI options: elective rotational atherectomy during trans-catheter aortic valve implantation

    International Nuclear Information System (INIS)

    Piccoli, Anna; Lunardi, Mattia; Ariotti, Sara; Ferrero, Valeria; Vassanelli, Corrado; Ribichini, Flavio

    2015-01-01

    Summary: Aortic valve stenosis (AVS) in the elderly is frequently associated to coronary artery disease (CAD). In patients with significant coronary stenosis surgical valve replacement is associated to coronary bypass grafting, but whether coronary angioplasty is needed in patients receiving trans-catheter aortic valve implantation (TAVI) is unknown. Given the frequent complexity of CAD in the elderly with calcific AVS, rotational atherectomy (RA) may be needed in some cases. No data are available about feasibility and safety of RA during TAVI. The need for myocardial revascularization in TAVI candidates is discussed, and a series of RA cases performed during TAVI is described

  1. Expanding TAVI options: elective rotational atherectomy during trans-catheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, Anna; Lunardi, Mattia; Ariotti, Sara; Ferrero, Valeria; Vassanelli, Corrado; Ribichini, Flavio, E-mail: flavio.ribichini@univr.it

    2015-01-15

    Summary: Aortic valve stenosis (AVS) in the elderly is frequently associated to coronary artery disease (CAD). In patients with significant coronary stenosis surgical valve replacement is associated to coronary bypass grafting, but whether coronary angioplasty is needed in patients receiving trans-catheter aortic valve implantation (TAVI) is unknown. Given the frequent complexity of CAD in the elderly with calcific AVS, rotational atherectomy (RA) may be needed in some cases. No data are available about feasibility and safety of RA during TAVI. The need for myocardial revascularization in TAVI candidates is discussed, and a series of RA cases performed during TAVI is described.

  2. Intraindividual variation in core microbiota in peri-implantitis and periodontitis

    Science.gov (United States)

    Maruyama, Noriko; Maruyama, Fumito; Takeuchi, Yasuo; Aikawa, Chihiro; Izumi, Yuichi; Nakagawa, Ichiro

    2014-01-01

    The oral microbiota change dramatically with each part of the oral cavity, even within the same mouth. Nevertheless, the microbiota associated with peri-implantitis and periodontitis have been considered the same. To improve our knowledge of the different communities of complex oral microbiota, we compared the microbial features between peri-implantitis and periodontitis in 20 patients with both diseases. Although the clinical symptoms of peri-implantitis were similar to those of periodontitis, the core microbiota of the diseases differed. Correlation analysis revealed the specific microbial co-occurrence patterns and found some of the species were associated with the clinical parameters in a disease-specific manner. The proportion of Prevotella nigrescens was significantly higher in peri-implantitis than in periodontitis, while the proportions of Peptostreptococcaceae sp. and Desulfomicrobium orale were significantly higher in periodontitis than in peri-implantitis. The severity of the peri-implantitis was also species-associated, including with an uncultured Treponema sp. that correlated to 4 clinical parameters. These results indicate that peri-implantitis and periodontitis are both polymicrobial infections with different causative pathogens. Our study provides a framework for the ecologically different bacterial communities between peri-implantitis and periodontitis, and it will be useful for further studies to understand the complex microbiota and pathogenic mechanisms of oral polymicrobial diseases. PMID:25308100

  3. The predictive value of microbiological findings on teeth, internal and external implant portions in clinical decision making.

    Science.gov (United States)

    Canullo, Luigi; Radovanović, Sandro; Delibasic, Boris; Blaya, Juan Antonio; Penarrocha, David; Rakic, Mia

    2017-05-01

    The primary aim of this study was to evaluate 23 pathogens associated with peri-implantitis at inner part of implant connections, in peri-implant and periodontal pockets between patients suffering peri-implantitis and participants with healthy peri-implant tissues; the secondary aim was to estimate the predictive value of microbiological profile in patients wearing dental implants using data mining methods. Fifty participants included in the present case─control study were scheduled for collection of plaque samples from the peri-implant pockets, internal connection, and periodontal pocket. Real-time polymerase chain reaction was performed to quantify 23 pathogens. Three predictive models were developed using C4.5 decision trees to estimate the predictive value of microbiological profile between three experimental sites. The final sample included 47 patients (22 healthy controls and 25 diseased cases), 90 implants (43 with healthy peri-implant tissues and 47 affected by peri-implantitis). Total and mean pathogen counts at inner portions of the implant connection, in peri-implant and periodontal pockets were generally increased in peri-implantitis patients when compared to healthy controls. The inner portion of the implant connection, the periodontal pocket and peri-implant pocket, respectively, presented a predictive value of microbiologic profile of 82.78%, 94.31%, and 97.5% of accuracy. This study showed that microbiological profile at all three experimental sites is differently characterized between patients suffering peri-implantitis and healthy controls. Data mining analysis identified Parvimonas micra as a highly accurate predictor of peri-implantitis when present in peri-implant pocket while this method generally seems to be promising for diagnosis of such complex infections. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Survival of dental implants in patients with Down syndrome: A case series.

    Science.gov (United States)

    Limeres Posse, Jacobo; López Jiménez, Julian; Ruiz Villandiego, José C; Cutando Soriano, Antonio; Fernández Feijoo, Javier; Linazasoro Elorza, Maialen; Diniz Freitas, Márcio; Diz Dios, Pedro

    2016-12-01

    The need for tooth replacement in individuals with Down syndrome (DS) is explained by the high prevalence of dental agenesis and by the premature loss of teeth through severe periodontal disease. Dental implants may be the dental procedure of choice in some of these patients. The purpose of this clinical study was to analyze dental implant survival in a series of patients with DS. This was a multicenter, retrospective, observational study. Information on patients was gathered using a standardized questionnaire designed specifically for this study, including personal details, oral health status, information on the surgical and prosthetic phases, and follow-up visits. The questionnaire was sent to centers registered with the research network of the Spanish Society of Special Needs Dentistry (SEOENE). Patients with DS aged 18 years or older were included in the study if they had at least 1 dental implant and the corresponding prosthesis and had been followed up for at least a year. The study population was formed of 25 adult patients (13 men and 12 women) aged between 19 and 60 years. The interventions were performed by 5 different dental surgeons, usually under general anesthesia or deep sedation (n=17 patients). A total of 73 implants were inserted, 30 in the maxilla and 43 in the mandible, most commonly in the anterior region (n=51). The mean time to loading the implants was 4.1 ±1.3 months after surgery (range, 1 to 7 months). All patients completed prosthetic rehabilitation; the most frequent design used was the single fixed prosthesis (n=13 patients). A total of 17 (23.2%) implants failed in 8 (32%) patients; the majority (n=14 implants) failed in the postsurgical period before implant loading. The distribution by patients was 1 implant failure in 6 patients, 3 failures in 1 patient, and 8 failures in 1 patient. Dental implant survival is lower in individuals with DS than in the general population. The reasons for early implant failure in these patients have

  5. Feasibility of a pre-implantation fitting test for an implantable hearing aid using a VR (virtual reality) software

    International Nuclear Information System (INIS)

    Dammann, F.; Bode, A.; Heuschmid, M.; Schwaderer, E.; Schaich, M.; Seemann, M.; Claussen, C.D.; Maassen, M.; Zenner, H.P.

    2001-01-01

    Purpose: To prove the feasibility of a preoperative fitting test for an implantable hearing aid using a VR environment. Methods: A high-resolution spiral CT was performed after mastoidectomy in 10 temporal bone specimens. The bony structures were segmented and merged with the computer-aided design (CAD) data of the hearing aid in a VR environment. For each specimen a three-dimensional fitting test was carried out by three examiners determining the implantability of the hearing aid. The implantation simulation was compared with the real implantation procedure performed by an experienced ENT surgeon. Results: The used VR system enabled real-time 3D-visualisation and manipulation of CT- and CAD-data. All objects could be independently moved in all three dimensions. The VR fitting test corresponded closely with the real implantation. The implantability of the hearing aid was properly predicted by all three examiners. Conclusion: Merging CT and CAD data in a virtual reality environment bears high potential for the presurgical determination of the fit and mountability of medical implants in complex anatomical regions. (orig.) [de

  6. [Cochlear implant in patients with congenital malformation of the inner ear].

    Science.gov (United States)

    Wan, Liang-cai; Guo, Meng-he; Qian, Yu-hong; Liu, Shuang-xiu; Zhang, Hong-zheng; Chen, Shuai-jun; Chen, Hao; Gong, Jian

    2009-10-01

    To summarize the clinical experience with multi-channel cochlear implantation in patients with inner ear malformations and evaluate and the outcomes of speech rehabilitation. A retrospective study was conducted in 295 patients receiving cochlear implantation from 1998 to 2007, including 25 patients with large vestibular aqueduct syndrome (LVAS), 9 with Modini malformation, and 5 with common cavity deformity. All the patients received the Nucleus24 cochlear implants. In LVAS cases, 4 had Nucleus 24R (ST) implants, 8 had Contuor implants, 10 had Contuor Advance, and the remaining cases used Nucleus24(M) straight-electrode implants. Severe gusher appeared in 3 cases of LVAS, and perilymph fluctuation were seen in other 15 cases. Four patients with Mondini malformation and 2 with common cavity malformation also experienced severe gusher, but the electrodes were inserted smoothly in all the patients without postoperative facial paralysis or cerebrospinal fluid leakage. The hearing threshold in these patients was similar to that in patients with normal cochlear structure. After speech rehabilitation for over 6 months, the abilities of speech discrimination and spoken language improved in all the cases in comparison with the preoperative lingual functions. Multi-channel cochlear implantation can be performed in patients with inner ear malformation, but should not be attempted in patients with poor cochlear and cochlear nerve development. A comprehensive pre-operative radiographic and audiological evaluation is essential.

  7. Single-Sided Deafness: Impact of Cochlear Implantation on Speech Perception in Complex Noise and on Auditory Localization Accuracy.

    Science.gov (United States)

    Döge, Julia; Baumann, Uwe; Weissgerber, Tobias; Rader, Tobias

    2017-12-01

    To assess auditory localization accuracy and speech reception threshold (SRT) in complex noise conditions in adult patients with acquired single-sided deafness, after intervention with a cochlear implant (CI) in the deaf ear. Nonrandomized, open, prospective patient series. Tertiary referral university hospital. Eleven patients with late-onset single-sided deafness (SSD) and normal hearing in the unaffected ear, who received a CI. All patients were experienced CI users. Unilateral cochlear implantation. Speech perception was tested in a complex multitalker equivalent noise field consisting of multiple sound sources. Speech reception thresholds in noise were determined in aided (with CI) and unaided conditions. Localization accuracy was assessed in complete darkness. Acoustic stimuli were radiated by multiple loudspeakers distributed in the frontal horizontal plane between -60 and +60 degrees. In the aided condition, results show slightly improved speech reception scores compared with the unaided condition in most of the patients. For 8 of the 11 subjects, SRT was improved between 0.37 and 1.70 dB. Three of the 11 subjects showed deteriorations between 1.22 and 3.24 dB SRT. Median localization error decreased significantly by 12.9 degrees compared with the unaided condition. CI in single-sided deafness is an effective treatment to improve the auditory localization accuracy. Speech reception in complex noise conditions is improved to a lesser extent in 73% of the participating CI SSD patients. However, the absence of true binaural interaction effects (summation, squelch) impedes further improvements. The development of speech processing strategies that respect binaural interaction seems to be mandatory to advance speech perception in demanding listening situations in SSD patients.

  8. [Phacoemulsification of subluxated lens with capsular tension ring implantation].

    Science.gov (United States)

    Dorecka, Mariola; Rokicki, Wojciech; Nita, Malgorzata; Krysik, Katarzyna; Nita, Ewa; Sikorska, Aleksandra; Romaniuk, Wanda

    2007-01-01

    To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation. The study comprised of 134 patients--146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed. No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration. (1) CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. (2) Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective procedure.

  9. Peri-Implantitis Associated with Type of Cement: A Retrospective Analysis of Different Types of Cement and Their Clinical Correlation to the Peri-Implant Tissue.

    Science.gov (United States)

    Korsch, Michael; Walther, Winfried

    2015-10-01

    The cementation of fixed implant-supported dental restorations involves the risk of leaving excess cement in the mouth which can promote biofilm formation in the peri-implant sulcus. As a result, an inflammation may develop. The aim of the present study was to investigate the clinical effect of two different luting cements on the peri-implant tissue. Within the scope of a retrospective clinical follow-up study, the prosthetic structures of 22 patients with 45 implants were revised. In all cases, a methacrylate cement (Premier Implant Cement [PIC], Premier® Dental Products Company, Plymouth Meeting, PA, USA) had been used for cementation. In 16 additional patients with 28 implants, the suprastructures were retained with a zinc oxide-eugenol cement (Temp Bond [TB], Kerr Sybron Dental Specialities, Glendora, CA, USA). These patients were evaluated in the course of routine treatment. In both populations, the retention time of the suprastructures was similar (TB 3.77 years, PIC 4.07 years). In the PIC cases, 62% of all implants had excess cement. In the TB cases, excess cement was not detectable on any of the implants. Bleeding on probing was significantly more frequent on implants cemented with PIC (100% with and 94% without excess cement) than on implants cemented with TB (46%). Pocket suppuration was observed on 89% of the PIC-cemented implants with excess cement (PIC without excess cement 24%), whereas implants with TB were not affected by it at all. The peri-implant bone loss was significantly greater in the PIC patients (with excess cement 1.37 mm, without excess cement 0.41 mm) than it was in the TB patients (0.07 mm). The frequency of undetected excess cement depends essentially on the type of cement used. Cements that tend to leave more undetected excess have a higher prevalence for peri-implant inflammation and cause a more severe peri-implant bone loss. © 2014 Wiley Periodicals, Inc.

  10. Poorer survival after a primary implant during revision total knee arthroplasty

    NARCIS (Netherlands)

    Meijer, Marrigje F.; Reininga, Inge H. F.; Boerboom, Alexander L.; Stevens, Martin; Bulstra, Sjoerd K.

    Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA. A retrospective

  11. Soft tissue grafting to improve implant esthetics

    Directory of Open Access Journals (Sweden)

    Moawia M Kassab

    2010-09-01

    Full Text Available Moawia M KassabDivision of Periodontics, Marquette University, School of Dentistry, Milwaukee, WI, USAAbstract: Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures.Keywords: case report, connective tissue, dental implants, allograft, coronally positioned flap

  12. A rare case report of peri-implant bone necrosis: Mapping the distance of initial peri-implant complication toward a path of success

    Directory of Open Access Journals (Sweden)

    S K Salaria

    2011-01-01

    Full Text Available In the past decade, science of implant placement has greatly advanced and at the same time much success has been experienced with the endosseous implant. Despite the long-term predictability of the implants, however, biological, technical and esthetic complications do occur. The use of osseointegrated implants as a foundation for prosthetic replacement of missing teeth has been highly predictable, but still at present, there is no consensus of how to best manage the complications occurring after implant placement. In this report, we discuss post-insertion complication of bone necrosis and its successful management.

  13. Suprapubic cystostomy for the management of urethral injuries during penile prosthesis implantation.

    Science.gov (United States)

    Anele, Uzoma A; Le, Brian V; Burnett, Arthur L

    2014-12-01

    Urethral injury is an uncommon surgical complication of penile prosthesis (PP) surgery. Conventional dogma requires abortion of the procedure if the adjacent corporal body is involved or delayed implantation to avert device infection associated with urinary extravasation. Besides the setback of the aborted surgery, this management approach also presents the possible difficulty of encountering corporal fibrosis at the time of reoperation. We report an approach using primary urethral repair and temporary suprapubic cystostomy for the management of incidental urethral injuries in a cohort of patients allowing for successful completion of unaborted PP implantation. We performed a retrospective analysis of all patients receiving PPs from 1990 to 2014 in which incidental urethral injuries were repaired and PP implantation was completed with suprapubic cystostomy (suprapubic tube [SPT] insertion). After allowing for urethral healing and urinary diversion via SPT for 4-8 weeks, the PP was activated. Successful management was determined by the absence of perioperative complications within 6 months of implantation. We identified four cases, all receiving inflatable PPs, managed with temporary suprapubic cystostomy. These patients sustained urethral injuries during corporal dissection (one patient), corporal dilation (one patient), and penile straightening (two patients). All patients were managed safely and successfully. Primary urethral repair followed by temporary suprapubic cystostomy offers a surgical approach to complete PP implantation successfully in patients who sustain urethral injury complications, particularly for complex PP surgeries. Anele UA, Le BV, and Burnett AL. Suprapubic cystostomy for the management of urethral injuries during penile prosthesis implantation.

  14. A combined prosthodontic and orthodontic treatment approach in a case of growth inhibition induced by dental implants: a case report.

    Science.gov (United States)

    Krieger, Elena; Wegener, Joachim; Wagner, Wilfried; Hornikel, Sandra; Wehrbein, Heinrich

    2012-01-01

    Functional and esthetic results can improve significantly when a combined prosthodontic-orthodontic treatment approach is employed in cases requiring extensive oral rehabilitation. The patient presented in this case report was treated in his late teens with dental implants as a replacement for his maxillary incisors. Ten years later, the entire maxillary anterior segment was in infraocclusion compared to the rest of the dentition and lip line. Since prosthodontic follow-up treatment alone could not achieve an optimal functional and esthetic outcome, the patient was treated orthodontically prior to renewing the restoration. A fixed appliance was used to intrude the mandibular anterior teeth as well as vertically align the infrapositioned maxillary lateral incisors.

  15. Application of interconnected porous hydroxyapatite ceramic block for onlay block bone grafting in implant treatment: A case report.

    Science.gov (United States)

    Ohta, Kouji; Tada, Misato; Ninomiya, Yoshiaki; Kato, Hiroki; Ishida, Fumi; Abekura, Hitoshi; Tsuga, Kazuhiro; Takechi, Masaaki

    2017-12-01

    Autogenous block bone grafting as treatment for alveolar ridge atrophy has various disadvantages, including a limited availability of sufficiently sized and shaped grafts, donor site morbidity and resorption of the grafted bone. As a result, interconnected porous hydroxyapatite ceramic (IP-CHA) materials with high porosity have been developed and used successfully in orthopedic cases. To the best of the author's knowledge, this is the first report of clinical application of an IP-CHA block for onlay grafting for implant treatment in a patient with horizontal alveolar atrophy. The present study performed onlay block grafting using an IP-CHA block to restore bone volume for implant placement in the alveolar ridge area without collecting autogenous bone. Dental X-ray findings revealed that the border of the IP-CHA block became increasingly vague over the 3-year period, whereas CT scanning revealed that the gap between the block and bone had a smooth transition, indicating that IP-CHA improved the process of integration with host bone. In follow-up examinations over a period of 5 years, the implants and superstructures had no problems. An IP-CHA block may be useful as a substitute for onlay block bone grafting in implant treatment.

  16. The non-specific symptoms of breast implant-associated anaplastic large cell lymphoma resulting in delayed diagnosis: A case-based review

    Directory of Open Access Journals (Sweden)

    Reem Dina Jarjis

    2015-12-01

    Full Text Available Breast implant-associated anaplastic large cell lymphoma (BIA-ALCL is a rare entity that has become known as a distinct clinical condition recently. In general, BIA-ALCL patients with a history of breast implants present with non-specific implant-related complications, resulting in delayed diagnosis and appropriate treatment because of the lack of awareness of BIA-ALCL. The cause and pathogenesis have still not been identified, and there are no evidence-based guidelines on how this condition should be detected, treated or followed up because of the rarity of available data. We present the first published Danish case of anaplastic lymphoma kinase negative BIA-ALCL, and review the current literature to raise awareness of and discuss management options for this rare clinical entity.

  17. Clinical decision-making by midwives: managing case complexity.

    Science.gov (United States)

    Cioffi, J; Markham, R

    1997-02-01

    In making clinical judgements, it is argued that midwives use 'shortcuts' or heuristics based on estimated probabilities to simplify the decision-making task. Midwives (n = 30) were given simulated patient assessment situations of high and low complexity and were required to think aloud. Analysis of verbal protocols showed that subjective probability judgements (heuristics) were used more frequently in the high than low complexity case and predominated in the last quarter of the assessment period for the high complexity case. 'Representativeness' was identified more frequently in the high than in the low case, but was the dominant heuristic in both. Reports completed after each simulation suggest that heuristics based on memory for particular conditions affect decisions. It is concluded that midwives use heuristics, derived mainly from their clinical experiences, in an attempt to save cognitive effort and to facilitate reasonably accurate decisions in the decision-making process.

  18. Dental Implant Placement with Simultaneous Anterior Maxillary Reconstruction with Block and Particulate Fresh Frozen Allograft Bone: A Case Report with 24-Month Follow-Up Data

    Directory of Open Access Journals (Sweden)

    J. S. Vieira

    2017-01-01

    Full Text Available Fresh frozen allograft bone is routinely used in orthopedic surgery for the reconstruction of large bone defects, and its use in oral and maxillofacial surgery is increasing. The purpose of this case was to demonstrate the installation of dental implants and the use of fresh frozen bone for reconstruction of anterior maxilla in the same surgery. This case report presents the insertion of dental implants followed immediately by a placement of fresh frozen allograft in block and particle for a reconstruction of atrophic anterior maxillary in the same surgery. Ten months subsequent to this procedure, provisional fixed prosthesis was installed on the implants. Four months later (postoperative month 14, the final fixed prosthesis was installed and the clinical success was observed. The insertion of dental implants followed immediately by a placement of fresh frozen allograft is a safe and efficient process that results in the successful return of dental function and aesthetic rehabilitation for the patient.

  19. Periodontal ligament formation around different types of dental titanium implants. I. The self-tapping screw type implant system

    DEFF Research Database (Denmark)

    Warrer, K; Karring, T; Gotfredsen, K

    1993-01-01

    The aim of this study was to determine if a periodontal ligament can form around self-tapping, screw type titanium dental implants. Implants were inserted in contact with the periodontal ligament of root tips retained in the mandibular jaws of 7 monkeys. In each side of the mandible, 1 premolar......, a periodontal ligament can form on self-tapping, screw type titanium dental implants in areas where a void is present between the surrounding bone and the implant at the time of insertion....... and 2 molars were removed in such a manner that in approximately half the cases, the root tips were retained. Following healing, the experimental areas were examined on radiographs, and sites were selected for the insertion of the implants, so that every second implant would have a close contact...

  20. Peri-implant stress correlates with bone and cement morphology: Micro-FE modeling of implanted cadaveric glenoids.

    Science.gov (United States)

    Wee, Hwabok; Armstrong, April D; Flint, Wesley W; Kunselman, Allen R; Lewis, Gregory S

    2015-11-01

    Aseptic loosening of cemented joint replacements is a complex biological and mechanical process, and remains a clinical concern especially in patients with poor bone quality. Utilizing high resolution finite element analysis of a series of implanted cadaver glenoids, the objective of this study was to quantify relationships between construct morphology and resulting mechanical stresses in cement and trabeculae. Eight glenoid cadavers were implanted with a cemented central peg implant. Specimens were imaged by micro-CT, and subject-specific finite element models were developed. Bone volume fraction, glenoid width, implant-cortex distance, cement volume, cement-cortex contact, and cement-bone interface area were measured. Axial loading was applied to the implant of each model and stress distributions were characterized. Correlation analysis was completed across all specimens for pairs of morphological and mechanical variables. The amount of trabecular bone with high stress was strongly negatively correlated with both cement volume and contact between the cement and cortex (r = -0.85 and -0.84, p implant-cortex distance. Contact between the cement and underlying cortex may dramatically reduce trabecular bone stresses surrounding the cement, and this contact depends on bone shape, cement amount, and implant positioning. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  1. Implantable biodegradable sponges: effect of interpolymer complex formation of chitosan with gelatin on the release behavior of tramadol hydrochloride.

    Science.gov (United States)

    Foda, Nagwa H; El-laithy, Hanan M; Tadros, Mina I

    2007-01-01

    The effect of interpolymer complex formation between positively charged chitosan and negatively charged gelatin (Type B) on the release behavior of tramadol hydrochloride from biodegradable chitosan-gelatin sponges was studied. Mixed sponges were prepared by freeze-drying the cross-linked homogenous stable foams produced from chitosan and gelatin solutions where gelatin acts as a foam builder. Generation of stable foams was optimized where concentration, pH of gelatin solution, temperature, speed and duration of whipping process, and, chitosan-gelatin ratio drastically affect the properties and the stability of the produced foams. The prepared sponges were evaluated for their morphology, drug content, and microstructure using scanning electron microscopy, mechanical properties, uptake capacity, drug release profile, and their pharmacodynamic activity in terms of the analgesic effect after implantation in Wistar rats. It was revealed that whipping 7% (w/w) gelatin solution, of pH 5.5, for 15 min at 25 degrees C with a stirring speed of 1000 rpm was the optimum conditions for stable gelatin foam generation. Moreover, homogenous, uniform chitosan-gelatin foam with small air bubbles were produced by mixing 2.5% w/w chitosan solution with 7% w/w gelatin solution in 1:5 ratio. Indeed, polyionic complexation between chitosan and gelatin overcame the drawbacks of chitosan sponge mechanical properties where, pliable, soft, and compressible sponge with high fluid uptake capacity was produced at 25 degrees C and 65% relative humidity without any added plasticizer. Drug release studies showed a successful retardation of the incorporated drug where the t50% values of the dissolution profiles were 0.55, 3.03, and 4.73 hr for cross-linked gelatin, un-cross-linked chitosan-gelatin, and cross-linked chitosan-gelatin sponges, respectively. All the release experiments followed Higuchi's diffusion mechanism over 12 hr. The achieved drug prolongation was a result of a combined effect

  2. Temporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.

    Science.gov (United States)

    Hwang, Sungsoon; Lim, Dong Hui; Lee, Soomin; Choi, Daye Diana; Chung, Eui-Sang; Chung, Tae-Young

    2018-04-01

    To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL implantation within the first 3 years of life from 1999 to 2013 at Samsung Medical Center were reviewed. Twenty-eight eyes from 18 patients underwent single IOL implantation (monopseudophakia group), and 32 eyes of 20 patients underwent temporary piggyback IOL implantation in congenital cataract surgery (polypseudophakia group). The mean age at initial cataract surgery was 15.8 months in the monopseudophakia group and 11.1 months in the polypseudophakia group (P = 0.144). The average follow-up duration was 133 months in the monopseudophakia group and 120 months in the polypseudophakia group (P = 0.391). The best-corrected visual acuity at the last visit was 0.36 logMAR in the monopseudophakia group and 0.55 logMAR in the polypseudophakia group (P = 0.044). Four (14%) and 14 (44%) reoperations for complications within the anterior segment were performed in the monopseudophakia group and polypseudophakia group, respectively (P = 0.042). Four cases (14.3%) in the monopseudophakia group and 13 cases (40.6%) in the polypseudophakia group had a glaucoma-related adverse event (P = 0.086). Compared with primary single IOL implantation in congenital cataract, temporary piggyback IOL implantation produced worse visual acuity, higher reoperation rate, and higher risk of secondary glaucoma. Temporary piggyback IOL implantation does not have benefit in congenital cataract.

  3. Wear properties of metal ion implanted 4140 steel

    International Nuclear Information System (INIS)

    Evans, P.J.; Paoloni, F.J.

    1994-01-01

    AISI type 4140 (high tensile) steel has been implanted with tungsten and titanium using a metal vapour vacuum arc ion source. Doses in the range (1-5)x10 16 ionscm -2 were implanted to a depth of approximately 30nm. The relative wear resistance between non-implanted and implanted specimens has been estimated using pin-on-disc and abrasive wear tests. Implantation of titanium decreased the area of wear tracks by a factor of 5 over unimplanted steel. In some cases the steel was also hardened by a liquid carburization treatment before implantation. Abrasion tests revealed a further improvement in wear resistance on this material following ion irradiation. ((orig.))

  4. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  5. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  6. A Novel Surgical Template Design in Staged Dental Implant Rehabilitations

    Directory of Open Access Journals (Sweden)

    Michael Patras

    2012-05-01

    Full Text Available Background: The philosophy of a gradual transition to an implant retained prosthesis in cases of full-mouth or extensive rehabilitation usually involves a staged treatment concept. In this therapeutic approach, the placement of implants may sometimes be divided into phases. During a subsequent surgical phase of treatment, the pre-existing implants can serve as anchors for the surgical template. Those modified surgical templates help in the precise transferring of restorative information into the surgical field and guide the optimal three-dimensional implant positioning. Methods: This article highlights the rationale of implant-retained surgical templates and illustrates them through the presentation of two clinical cases. The templates are duplicates of the provisional restorations and are secured to the existing implants through the utilization of implant mounts. Results: This template design in such staged procedures provided stability in the surgical field and enhanced the accuracy in implant positioning based upon the planned restoration, thus ensuring predictable treatment outcomes.Conclusions: Successful rehabilitation lies in the correct sequence of surgical and prosthetic procedures. Whenever a staged approach of implant placement is planned, the clinician can effectively use the initially placed implants as anchors for the surgical template during the second phase of implant surgery.

  7. High-grade Angiosarcoma Associated with Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Nicolas R. Smoll, MBBS

    2013-04-01

    Full Text Available Summary: Since the serendipitous discovery that implanted polymers cause sarcomas in rats, much research has been conducted to prove or disprove a link between silicone breast implants and/or polymer-based materials and breast cancer. In light of an initial report that 35% of rats implanted with a variety of polymers developed fibrosarcomas, we report a case of primary angiosarcoma found in a patient presenting with bilateral rupture of gel-filled breast implants.

  8. Biofilm and dental implant: The microbial link

    Directory of Open Access Journals (Sweden)

    Sangeeta Dhir

    2013-01-01

    Full Text Available Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals - clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human studies, abstracts, review articles.

  9. Simulations of Proton Implantation in Silicon Carbide (SiC)

    Science.gov (United States)

    2016-03-31

    Simulations of Proton Implantation in Silicon Carbide (SiC) Jonathan P. McCandless, Hailong Chen, Philip X.-L. Feng Electrical Engineering, Case...of implanting protons (hydrogen ions, H+) into SiC thin layers on silicon (Si) substrate, and explore the ion implantation conditions that are...relevant to experimental radiation of SiC layers. Keywords: silicon carbide (SiC); radiation effects; ion implantation ; proton; stopping and range of

  10. Implant Therapy in the Esthetic Zone-Surgical Considerations

    Directory of Open Access Journals (Sweden)

    Marković Aleksa

    2016-07-01

    Full Text Available Implant placement in the esthetic zone is a complex procedure and requires a restoration-driven approach. Proper selection of patients and implant together with individual assessment of the risk of esthetic complications are very important. Correct 3D-implant positioning and sufficient bone volume should provide long-term esthetic and function. Esthetic region is a zone in which expectations and possibilities collide. Clinician should bring the important decision on the appropriate time of implant placement. Immediate implant placement is particularly challenging in the esthetic zone. Patient desire for reduced treatment time should be weighed against the possible risk factors. Protocol of immediate implant placement in conditions of unfavourable gingival biotypes, the lack of bone or soft tissue in patients with a high smile line lead to esthetic failure which is very important in the esthetic region.

  11. A Novel Treatment Decision Tree and Literature Review of Retrograde Peri-Implantitis.

    Science.gov (United States)

    Sarmast, Nima D; Wang, Howard H; Soldatos, Nikolaos K; Angelov, Nikola; Dorn, Samuel; Yukna, Raymond; Iacono, Vincent J

    2016-12-01

    Although retrograde peri-implantitis (RPI) is not a common sequela of dental implant surgery, its prevalence has been reported in the literature to be 0.26%. Incidence of RPI is reported to increase to 7.8% when teeth adjacent to the implant site have a previous history of root canal therapy, and it is correlated with distance between implant and adjacent tooth and/or with time from endodontic treatment of adjacent tooth to implant placement. Minimum 2 mm space between implant and adjacent tooth is needed to decrease incidence of apical RPI, with minimum 4 weeks between completion of endodontic treatment and actual implant placement. The purpose of this study is to compile all available treatment modalities and to provide a decision tree as a general guide for clinicians to aid in diagnosis and treatment of RPI. Literature search was performed for articles published in English on the topic of RPI. Articles selected were case reports with study populations ranging from 1 to 32 patients. Any case report or clinical trial that attempted to treat or rescue an implant diagnosed with RPI was included. Predominant diagnostic presentation of a lesion was presence of sinus tract at buccal or facial abscess of apical portion of implant, and subsequent periapical radiographs taken demonstrated a radiolucent lesion. On the basis of case reports analyzed, RPI was diagnosed between 1 week and 4 years after implant placement. Twelve of 20 studies reported that RPI lesions were diagnosed within 6 months after implant placement. A step-by-step decision tree is provided to allow clinicians to triage and properly manage cases of RPI on the basis of recommendations and successful treatments provided in analyzed case reports. It is divided between symptomatic and asymptomatic implants and adjacent teeth with vital and necrotic pulps. Most common etiology of apical RPI is endodontic infection from neighboring teeth, which was diagnosed within 6 months after implant placement. Most

  12. Fracture of a HTR-PMI cranioplastic implant after severe TBI.

    Science.gov (United States)

    López González, Antonio; Pérez Borredá, Pedro; Conde Sardón, Rebeca

    2015-02-01

    A 13-year-old girl with a large left fronto-parietal hard-tissue replacement patient-matched implant (HTR®-PMI) cranioplasty-since she suffered from a traumatic brain injury (TBI) 6 years ago-had a new severe TBI that detached and fractured the implant as well as caused a left subdural hematoma and a large frontal contusion. The hematoma and contusion were removed and the implant was substituted by a provisional titanium mesh. To the best of our knowledge, this is the first case reported about an HTR®-PMI fracture. It is theorized that the bone ingrowth into the macroporous implants, like those of hydroxyapatite, gives strength and resistance to the implant. But in the case we describe, no macroscopic bone ingrowth was detected 6 years after implantation and the traumatic force that impacted over the cranioplasty exceeded its properties.

  13. Strain profiles in ion implanted ceramic polycrystals: An approach based on reciprocal-space crystal selection

    Energy Technology Data Exchange (ETDEWEB)

    Palancher, H., E-mail: herve.palancher@cea.fr; Martin, G.; Fouet, J. [CEA, DEN, DEC, F-13108 Saint Paul lez Durance (France); Goudeau, P. [Institut Pprime, CNRS-Université de Poitiers–ENSMA, SP2MI, F-86360 Chasseneuil (France); Boulle, A. [Science des Procédés Céramiques et Traitements de Surface (SPCTS), CNRS UMR 7315, Centre Européen de la Céramique, 12 rue Atlantis, 87068 Limoges (France); Rieutord, F. [CEA, DSM, INAC, F-38054 Grenoble Cedex 9 (France); Favre-Nicolin, V. [Université Grenoble-Alpes, F-38041 Grenoble, France, Institut Universitaire de France, F-75005 Paris (France); Blanc, N. [Institut NEEL, CNRS-Univ Grenoble Alpes, F-38042 Grenoble (France); Onofri, C. [CEA, DEN, DEC, F-13108 Saint Paul lez Durance (France); CEMES, CNRS UPR 8011, 29 rue Jeanne Marvig, BP 94347, 31055 Toulouse Cedex 4 (France)

    2016-01-18

    The determination of the state of strain in implanted materials is a key issue in the study of their mechanical stability. Whereas this question is nowadays relatively easily solved in the case of single crystals, it remains a challenging task in the case of polycrystalline materials. In this paper, we take benefit of the intense and parallel beams provided by third generation synchrotron sources combined with a two-dimensional detection system to analyze individual grains in polycrystals, hence obtaining “single crystal-like” data. The feasibility of the approach is demonstrated with implanted UO{sub 2} polycrystals where the in-depth strain profile is extracted for individual grains using numerical simulations of the diffracted signal. The influence of the implantation dose is precisely analyzed for several diffracting planes and grains. This work suggests that, at low fluences, the development of strain is mainly due to ballistic effects with little effect from He ions, independently from the crystallographic orientation. At higher fluences, the evolution of the strain profiles suggests a partial and anisotropic plastic relaxation. With the present approach, robust and reliable structural information can be obtained, even from complex polycrystalline ceramic materials.

  14. Operation of low-energy ion implanters for Si, N, C ion implantation into silicon and glassy carbon

    International Nuclear Information System (INIS)

    Carder, D.A.; Markwitz, A.

    2009-01-01

    This report details the operation of the low-energy ion implanters at GNS Science for C, N and Si implantations. Two implanters are presented, from a description of the components through to instructions for operation. Historically the implanters have been identified with the labels 'industrial' and 'experimental'. However, the machines only differ significantly in the species of ions available for implantation and sample temperature during implantation. Both machines have been custom designed for research purposes, with a wide range of ion species available for ion implantation and the ability to implant two ions into the same sample at the same time from two different ion sources. A fast sample transfer capability and homogenous scanning profiles are featured in both cases. Samples up to 13 mm 2 can be implanted, with the ability to implant at temperatures down to liquid nitrogen temperatures. The implanters have been used to implant 28 Si + , 14 N + and 12 C + into silicon and glassy carbon substrates. Rutherford backscattering spectroscopy has been used to analyse the implanted material. From the data a Si 30 C 61 N 9 layer was measured extending from the surface to a depth of about 77 ± 2 nm for (100) silicon implanted with 12 C + and 14 N + at multiple energies. Silicon and nitrogen ion implantation into glassy carbon produced a Si (40.5 %), C (38 %), N (19.5 %) and O (2%) layer centred around a depth of 50 ± 2 nm from the surface. (author). 8 refs., 20 figs

  15. SIMS analysis of isotopic impurities in ion implants

    International Nuclear Information System (INIS)

    Sykes, D.E.; Blunt, R.T.

    1986-01-01

    The n-type dopant species Si and Se used for ion implantation in GaAs are multi-isotopic with the most abundant isotope not chosen because of potential interferences with residual gases. SIMS analysis of a range of 29 Si implants produced by several designs of ion implanter all showed significant 28 Si impurity with a different depth distribution from that of the deliberately implanted 29 Si isotope. This effect was observed to varying degrees with all fifteen implanters examined and in every 29 Si implant analysed to date 29 Si + , 29 Si ++ and 30 Si implants all show the same effect. In the case of Se implantation, poor mass resolution results in the implantation of all isotopes with the same implant distribution (i.e. energy), whilst implants carried out with good mass resolution show the implantation of all isotopes with the characteristic lower depth distribution of the impurity isotopes as found in the Si implants. This effect has also been observed in p-type implants into GaAs (Mg) and for Ga implanted in Si. A tentative explanation of the effect is proposed. (author)

  16. Systemic Sclerosis and Silicone Breast Implant: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Antonios Psarras

    2014-01-01

    Full Text Available Environmentally induced systemic sclerosis is a well-recognized condition, which is correlated with exposure to various chemical compounds or drugs. However, development of scleroderma-like disease after exposure to silicone has always been a controversial issue and, over time, it has triggered spirited debate whether there is a certain association or not. Herein, we report the case of a 35-year-old female who developed Raynaud’s phenomenon and, finally, systemic sclerosis shortly after silicone breast implantation surgery.

  17. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  18. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  19. Risk factors and periimplantitis in implant therapy. Narrative review

    Directory of Open Access Journals (Sweden)

    Francis Bravo

    2013-12-01

    Full Text Available Diseases involving tissue around the teeth and osseointegrated implants are the result of an interaction between some type of pathological agent (bacterial, viral, etc. and host immune response. These interactions can occur both in the dental tissues as those biomaterials which are introduced to attempt to correct some type of periodontal disease, the implant being a biocompatible substitute of the teeth is not free from this type of interaction often enrolled periodontal and peri-implant pathology. The peri-implantitis is a type of disease that results from this interaction, the risk factors and risk indicators of peri-implantitis are broad and complex. This article summarizes the multiple sources of information in the scientific literature to address in detail the aspects of the main risk factors and the peri-implantitis in the peri implant therapy.

  20. Enhanced electrical activation of Zn and Be implants in GaAs by the co-implantation of phosphorus

    International Nuclear Information System (INIS)

    Tang, A.C.T.; Sealy, B.J.; Rezazadeh, A.A.

    1989-01-01

    In this paper, we report that, through the use of rapid thermal annealing (RTA) and the co-implantation of phosphorus, an effective way of preventing the in- and out-diffusion of zinc and beryllium has been achieved in GaAs. This is of particular significance in the case of the beryllium implanted samples because, to date, there has been no method for preventing the out-diffusion of beryllium atoms at high annealing temperatures. We have observed that the reverse annealing behaviour of the Be-implanted samples has been modified after the co-implantation of phosphorus. Furthermore, abrupt electrical profiles with hole concentrations of the order of 6x10 19 cm -3 have been achieved with the Zn+P implants after annealing at 850 0 C for 30 s. (author)

  1. Cranioplasty with individual titanium implants

    Science.gov (United States)

    Mishinov, S.; Stupak, V.; Sadovoy, M.; Mamonova, E.; Koporushko, N.; Larkin, V.; Novokshonov, A.; Dolzhenko, D.; Panchenko, A.; Desyatykh, I.; Krasovsky, I.

    2017-09-01

    Cranioplasty is the second procedure in the history of neurosurgery after trepanation, and it is still relevant despite the development of civilization and progress in medicine. Each cranioplasty operation is unique because there are no two patients with identical defects of the skull bones. The development of Direct Metal Laser Sintering (DMLS) technique opened up the possibility of direct implant printing of titanium, a biocompatible metal used in medicine. This eliminates the need for producing any intermediate products to create the desired implant. We have produced 8 patient-specific titanium implants using this technique for patients who underwent different decompressive cranioectomies associated with bone tumors. Follow-up duration ranged from 6 to 12 months. We observed no implant-related reactions or complications. In all cases of reconstructive neurosurgery we achieved good clinical and aesthetic results. The analysis of the literature and our own experience in three-dimensional modeling, prototyping, and printing suggests that direct laser sintering of titanium is the optimal method to produce biocompatible surgical implants.

  2. Ion implantation of boron in germanium

    International Nuclear Information System (INIS)

    Jones, K.S.

    1985-05-01

    Ion implantation of 11 B + into room temperature Ge samples leads to a p-type layer prior to any post implant annealing steps. Variable temperature Hall measurements and deep level transient spectroscopy experiments indicate that room temperature implantation of 11 B + into Ge results in 100% of the boron ions being electrically active as shallow acceptor, over the entire dose range (5 x 10 11 /cm 2 to 1 x 10 14 /cm 2 ) and energy range (25 keV to 100 keV) investigated, without any post implant annealing. The concentration of damage related acceptor centers is only 10% of the boron related, shallow acceptor center concentration for low energy implants (25 keV), but becomes dominant at high energies (100 keV) and low doses ( 12 /cm 2 ). Three damage related hole traps are produced by ion implantation of 11 B + . Two of these hole traps have also been observed in γ-irradiated Ge and may be oxygen-vacancy related defects, while the third trap may be divacancy related. All three traps anneal out at low temperatures ( 0 C). Boron, from room temperature implantation of BF 2 + into Ge, is not substitutionally active prior to a post implant annealing step of 250 0 C for 30 minutes. After annealing additional shallow acceptors are observed in BF 2 + implanted samples which may be due to fluorine or flourine related complexes which are electrically active

  3. Dramatic course of osteomyelitis in a patient treated with immediately placed dental implants suffering from uncontrolled diabetes: A case report.

    Science.gov (United States)

    Doll, Christian; Hartwig, Stefan; Nack, Claudia; Nahles, Susanne; Nelson, Katja; Raguse, Jan-Dirk

    2015-01-01

    To report a rare and dramatic complication following immediate dental implant placement in a heavy smoker, who had a delayed diagnosis of uncontrolled diabetes. In this case report we present the dramatic course of a 64-year old female patient treated with five immediate post-extractive dental implants in the mandible, who developed osteomyelitis, which manifested initially as local peri-implant inflammation and progressed into a spontaneous jaw fracture, despite repeated surgical interventions and antibiotic courses over a 3-year period, until diabetes was diagnosed. A symptom-free status could be achieved only after partial mandibulectomy, treatment of diabetes and reconstruction with a microvascular fibula free flap. In the presence of mandibular osteomyelitis refractory to therapy, yet undiagnosed underlying pathologies, such as diabetes, should be investigated and treated urgently.

  4. Giant desmoid tumour of the thorax following latissimus dorsi and implant breast reconstruction: case report and review of the literature

    LENUS (Irish Health Repository)

    Collins, AM

    2017-03-01

    The case of a giant thoracic desmoid tumour in a 44-year-old woman, who presented two years following a breast reconstruction with a latissimus dorsi (LD) flap and implant, is reported. Clinical findings included a rapidly growing, painless mass. Computed tomography (CT) suggested skin and intercostal soft tissue invasion. The tumour was resected en bloc with the LD muscle, implant capsule and underlying rib segments. The resultant thoracic and abdominal wall defects were reconstructed with Dualmesh® and polypropylene meshes respectively. There was no evidence of recurrence at thirty-six months follow-up.

  5. Wear properties of metal ion implanted 4140 steel

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J. (Applications of Nuclear Physics, Ansto, Private Mail Bag 1, Menai, NSW 2234 (Australia)); Paoloni, F.J. (Department of Electrical and Computer Engineering, University of Wollongong, GPO Box 1144, Wollongong, NSW 2500 (Australia))

    1994-07-01

    AISI type 4140 (high tensile) steel has been implanted with tungsten and titanium using a metal vapour vacuum arc ion source. Doses in the range (1-5)x10[sup 16]ionscm[sup -2] were implanted to a depth of approximately 30nm. The relative wear resistance between non-implanted and implanted specimens has been estimated using pin-on-disc and abrasive wear tests. Implantation of titanium decreased the area of wear tracks by a factor of 5 over unimplanted steel. In some cases the steel was also hardened by a liquid carburization treatment before implantation. Abrasion tests revealed a further improvement in wear resistance on this material following ion irradiation. ((orig.))

  6. Influence of Number of Implants and Attachment Type on Stress Distribution in Mandibular Implant-Retained Overdentures: Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Mohamed I. El-Anwar

    2017-03-01

    CONCLUSION: Caps deformation and stresses are negligible in cases of using locator attachment in comparison to ball attachments. This may indicate longer lifetime and less repair/maintenance operations in implant overdentures retained by locator attachments. Although the study revealed that bone was insensitive to a number of implants or attachment type, it may be recommended to use two implants in the canine region than using four, where the locator attachments were found to be better.

  7. Design Considerations for Developing Biodegradable Magnesium Implants

    Science.gov (United States)

    Brar, Harpreet S.; Keselowsky, Benjamin G.; Sarntinoranont, Malisa; Manuel, Michele V.

    The integration of biodegradable and bioabsorbable magnesium implants into the human body is a complex undertaking that faces major challenges. The complexity arises from the fact that biomaterials must meet both engineering and physiological requirements to ensure the desired properties. Historically, efforts have been focused on the behavior of commercial magnesium alloys in biological environments and their resultant effect on cell-mediated processes. Developing causal relationships between alloy chemistry and micro structure, and its effect on cellular behavior can be a difficult and time intensive process. A systems design approach driven by thermodynamics has the power to provide significant contributions in developing the next generation of magnesium alloy implants with controlled degradability, biocompatibility, and optimized mechanical properties, at reduced time and cost. This approach couples experimental research with theory and mechanistic modeling for the accelerated development of materials. The aim of this article is to enumerate this strategy, design considerations and hurdles for developing new magnesium alloys for use as biodegradable implant materials [1].

  8. Chronic Orbital Inflammation Associated to Hydroxyapatite Implants in Anophthalmic Sockets

    Directory of Open Access Journals (Sweden)

    Alicia Galindo-Ferreiro

    2017-12-01

    Full Text Available Purpose: We report 6 patients who received a hydroxyapatite (HA orbital implant in the socket and developed chronic orbital inflammation unresponsive to conventional medical therapy. Case Reports: We assisted 6 cases (4 males, 2 females who received an HA orbital implant in the socket between 2015 and 2016 at King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia, and developed chronic orbital inflammation with chronic discharge, redness, and pain (onset from weeks to over 2 decades after surgery. Computed tomography evaluation indicated inflammation in the orbital tissues, and histological examination showed a foreign body granulomatous reaction mainly localized around and blanching the HA implant. The condition was unresponsive to usual medical treatment and was resolved immediately after implant removal. Conclusions: Chronic inflammation can occur decades after placement of an HA implant in the orbit and can be successfully treated with implant removal.

  9. Effects of repeated manual disassembly and reassembly on the position stability of various implant-abutment complexes

    OpenAIRE

    Semper, Wiebke

    2010-01-01

    In this experiment the precision of manually repositioned abutments in five implant systems with various implant-abutment interfaces was evaluated. Material und Method Of these five implant systems (Straumann, Astra Tech, Replace Select, Camlog, SteriOss) six angled (0°, 5°, 15°) implants each were fixated in a prefabricated metal block. Three persons with differing experience and knowledge of the hypothesis placed and removed a prefabricated abutment with anti-rotational features ...

  10. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    Science.gov (United States)

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  11. Complications and results of subdural grid electrode implantation in epilepsy surgery.

    Science.gov (United States)

    Lee, W S; Lee, J K; Lee, S A; Kang, J K; Ko, T S

    2000-11-01

    We assessed the risk of delayed subdural hematoma and other complications associated with subdural grid implantation. Forty-nine patients underwent subdural grid implantation with/without subdural strips or depth electrodes from January 1994 to August 1998. To identify the risk associated with subdural grid implantation, a retrospective review of all patients' medical records and radiological studies was performed. The major complications of 50 subdural grid electrode implantations were as follows: four cases (7.8%) of delayed subdural hematoma at the site of the subdural grid, requiring emergency operation; two cases (3.9%) of infection; one case (2.0%) of epidural hematoma; and one case (2.0%) of brain swelling. After subdural hematoma removal, the electrodes were left in place. CCTV monitoring and cortical stimulation studies were continued thereafter. No delayed subdural hematoma has occurred since routine placement of subdural drains was begun. In our experience the worst complication of subdural grid implantation has been delayed subdural hematoma. Placement of subdural drains and close observation may be helpful to prevent this serious complication.

  12. Hair Barrette Induced Cochlear Implant Receiver Stimulator Site Infection with Extrusion

    Directory of Open Access Journals (Sweden)

    Trung N. Le

    2015-01-01

    Full Text Available Background. Cochlear implant infections and extrusion are uncommon but potentially devastating complications. Recent literature suggests conservative management can be employed. Local measures inclusive of aggressive surgical debridement with vascularized flaps and parenteral antibiotics represent a viable option and often permit device salvage. However, explantation should be considered if there is evidence of systemic, intracranial, or intractable infection. Method. A Case report and literature review. Case Report. This case illustrates a complicated local wound infection associated with cochlear implantation due to transcutaneous adherence of a ferrous hair barrette to a cochlear implant magnet. Reconstruction of computed tomography (CT data with 3D volume rendering significantly improved the value of the images and facilitated patient counseling as well as operative planning. Conclusion. Cochlear implant infections can be associated with foreign bodies. CT images are beneficial in the evaluation of cochlear implant complications. 3D CT images provide a comprehensive view of the site of interest, displaying the relationship of the hardware to the skull and soft tissues, while minimizing associated artifacts. Cochlear implant patients should consider use of nonmetallic hair devices.

  13. Effects of high-dose hydrogen implantation on defect formation and dopant diffusion in silver implanted ZnO crystals

    Energy Technology Data Exchange (ETDEWEB)

    Yaqoob, Faisal [Department of Physics, State University of New York at Albany, Albany, New York 12222 (United States); Huang, Mengbing, E-mail: mhuang@sunypoly.edu [College of Nanoscale Science and Engineering, State University of New York Polytechnic Institute, Albany, New York 12203 (United States)

    2016-07-28

    This work reports on the effects of a deep high-dose hydrogen ion implant on damage accumulation, defect retention, and silver diffusion in silver implanted ZnO crystals. Single-crystal ZnO samples were implanted with Ag ions in a region ∼150 nm within the surface, and some of these samples were additionally implanted with hydrogen ions to a dose of 2 × 10{sup 16 }cm{sup −2}, close to the depth ∼250 nm. Rutherford backscattering/ion channeling measurements show that crystal damage caused by Ag ion implantation and the amount of defects retained in the near surface region following post-implantation annealing were found to diminish in the case with the H implantation. On the other hand, the additional H ion implantation resulted in a reduction of substitutional Ag atoms upon post-implantation annealing. Furthermore, the presence of H also modified the diffusion properties of Ag atoms in ZnO. We discuss these findings in the context of the effects of nano-cavities on formation and annihilation of point defects as well as on impurity diffusion and trapping in ZnO crystals.

  14. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

    Science.gov (United States)

    Rack, A; Rack, T; Stiller, M; Riesemeier, H; Zabler, S; Nelson, K

    2010-03-01

    Micro-gap formation at the implant-abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites.

  15. Slow positron beam study of hydrogen ion implanted ZnO thin films

    International Nuclear Information System (INIS)

    Hu, Yi; Xue, Xudong; Wu, Yichu

    2014-01-01

    The effects of hydrogen related defect on the microstructure and optical property of ZnO thin films were investigated by slow positron beam, in combination with x-ray diffraction, infrared and photoluminescence spectroscopy. The defects were introduced by 90 keV proton irradiation with doses of 1×10 15 and 1×10 16 ions cm −2 . Zn vacancy and OH bonding (V Zn +OH) defect complex were identified in hydrogen implanted ZnO film by positron annihilation and infrared spectroscopy. The formation of these complexes led to lattice disorder in hydrogen implanted ZnO film and suppressed the luminescence process. - Highlights: • Hydrogen introduced by ion implantation can form hydrogen-related defect complex. • V Zn +OH defect complex is identified by positron annihilation and IR spectroscopy. • Irradiation defects suppress the luminescence process

  16. [Pannus Formation Two Years after Bioprosthetic Aortic Valve Implantation;Report of a Case].

    Science.gov (United States)

    Ono, Kimiyo; Kuroda, Hiroaki

    2015-08-01

    We report a case of early deterioration of the bioprosthetic aortic valve 23 months postoperatively. A 77-year-old man who had undergone aortic valve replacement with a 23-mm Epic valve( St. Jude Medical [SJM])presented to us after a syncopal episode. Echocardiography revealed severe aortic stenosis, and redo aortic valve replacement with a 21-mm SJM mechanical valve was performed. All 3 cusps of the tissue valve were thickened by fibrous pannus overgrowth. Neither calcification nor invasion of inflammatory cells was observed. The cause of pannus formation at such an early stage after implantation remains unknown.

  17. Neurocognitive testing and cochlear implantation: insights into performance in older adults

    Directory of Open Access Journals (Sweden)

    Cosetti MK

    2016-05-01

    Full Text Available Maura K Cosetti,1,2 James B Pinkston,3 Jose M Flores,4 David R Friedmann,5 Callie B Jones,3 J Thomas Roland Jr,5,6 Susan B Waltzman5 1Department of Otolaryngology – Head and Neck Surgery, 2Department of Neurosurgery, 3Department of Neurology, Louisiana State University Health Sciences Center, Shreveport, LA, 4Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MA, 5Department of Otolaryngology, 6Department of Neurosurgery, New York University School of Medicine, New York, NY, USA Objective: The aim of this case series was to assess the impact of auditory rehabilitation with cochlear implantation on the cognitive function of elderly patients over time. Design: This is a longitudinal case series of prospective data assessing neurocognitive function and speech perception in an elderly cohort pre- and post-implantation. Setting: University cochlear implant center. Participants: The patients were post-lingually deafened elderly female (mean, 73.6 years; SD, 5.82; range, 67–81 years cochlear implant recipients (n=7. Measurements: A neurocognitive battery of 20 tests assessing intellectual function, learning, short- and long-term memory, verbal fluency, attention, mental flexibility, and processing speed was performed prior to and 2–4.1 years (mean, 3.7 after cochlear implant (CI. Speech perception testing using Consonant–Nucleus–Consonant words was performed prior to implantation and at regular intervals postoperatively. Individual and aggregate differences in cognitive function pre- and post-CI were estimated. Logistic regression with cluster adjustment was used to estimate the association (%improvement or %decline between speech understanding and years from implantation at 1 year, 2 years, and 3 years post-CI. Results: Improvements after CI were observed in 14 (70% of all subtests administered. Declines occurred in five (25% subtests. In 55 individual tests (43%, post-CI performance improved

  18. Iodine-125 seed implantation for unresectable pancreatic carcinoma guided by intraoperative ultrasound

    International Nuclear Information System (INIS)

    Wang Junjie; Xiu Dianrong; Ran Weiqiang; Bai Jing; Zhu Lihong; Liu Jiangping

    2005-01-01

    Objective: To investigate the surgical technique, efficacy and side effects of 125 I seed interstitial implantation for pancreatic carcinoma. Methods: A total of 22 patients with biopsy proven unresectable adenocarcinoma of pancreas were treated with 125 I implants during laparotomy. Of them 11 patients were treated previously by a combination of bypass surgery. The stent was implanted in 2 cases 2 weeks before and 4 weeks after seed implantation. Seed needles were implanted parallelly to each other, with 1-1.5 cm apart. Mick applicator was being connected to each needle to implant seed. The radioactive activity ranged 0.40-0.70 mCi, the matched peripheral doses were 65-145 Gy. The mean number of 125 I seed was 11-78. Five cases received external beam irradiation with 3D-CRT, the doses were 39-70 Gy and 5 patients received 2 cycle of gemcitabine chemotherapy at 1000 mg/m 2 on dl and d8. Results: Pain was completely relieved in 12 cases, partially relieved in 2 cases, and no response was noted in one case, so the response rate was 93.33%. The median time was 2-3 d. Altogethe 27.27% of the cases died from local recurrence of pancreatic carcinoma and 50% from metastasis. The median survival time in these patients was 6 months, with a 2-year survival rate of 9.09%. The seed immigrated to liver in 3 cases. There were no serious side effects such as infection, pancreatitis, pancreatic fistula, etc. Conclusion: Radioactive seed implantation was safe, high local control, minidamage, satisfactory palliation of pain and without significant complications. (authors)

  19. Vertical Root Fracture: Preservation of the Alveolar Ridge Using Immediate Implants

    Directory of Open Access Journals (Sweden)

    Edmar de Oliveira Oya

    2014-01-01

    Full Text Available Teeth with vertical root fracture (VRF have complete or incomplete fractures that begin in the root and extend toward the occlusal surface. The most frequent causes of VRF originate from physical trauma, occlusal prematurity, inadequate endodontic treatment, and iatrogenic causes. Diagnose is difficult and delay can cause stomatognathic system problem. The purpose of this case report was to evaluate immediate implant placement after extraction of teeth with vertical root fracture. For the 1st case, the VRF in 1st left lower molar was confirmed during surgical flap and at the same time, the tooth was removed and immediate implant was placed. For the 2nd case, the VRF 1st left lower molar was confirmed during endodontic access and at the same appointment, the tooth was removed and the immediate implant is placed. Several studies have shown that immediate implants have similar success rates when compared with late implants. Consider that this approach is a safe procedure with favorable prognosis. In cases of VRF, the main factor to be considered is the presence of adequate bone support and immediate implants can preserve the vertical bone height, adding the fact that good patient compliance reduces the number of surgical interventions and promotes the functionality of stomatognathic system.

  20. Electromagnetic Radiation Efficiency of Body-Implanted Devices

    Science.gov (United States)

    Nikolayev, Denys; Zhadobov, Maxim; Karban, Pavel; Sauleau, Ronan

    2018-02-01

    Autonomous wireless body-implanted devices for biotelemetry, telemedicine, and neural interfacing constitute an emerging technology providing powerful capabilities for medicine and clinical research. We study the through-tissue electromagnetic propagation mechanisms, derive the optimal frequency range, and obtain the maximum achievable efficiency for radiative energy transfer from inside a body to free space. We analyze how polarization affects the efficiency by exciting TM and TE modes using a magnetic dipole and a magnetic current source, respectively. Four problem formulations are considered with increasing complexity and realism of anatomy. The results indicate that the optimal operating frequency f for deep implantation (with a depth d ≳3 cm ) lies in the (108- 109 )-Hz range and can be approximated as f =2.2 ×107/d . For a subcutaneous case (d ≲3 cm ), the surface-wave-induced interference is significant: within the range of peak radiation efficiency (about 2 ×108 to 3 ×109 Hz ), the max-to-min ratio can reach a value of 6.5. For the studied frequency range, 80%-99% of radiation efficiency is lost due to the tissue-air wave-impedance mismatch. Parallel polarization reduces the losses by a few percent; this effect is inversely proportional to the frequency and depth. Considering the implantation depth, the operating frequency, the polarization, and the directivity, we show that about an order-of-magnitude efficiency improvement is achievable compared to existing devices.

  1. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  2. Radiological evaluation of long term complications of oral rehabilitations of thin ridges with titanium blade implants

    Directory of Open Access Journals (Sweden)

    P. Diotallevi

    2014-03-01

    Full Text Available Aim: The aim of this study was to assess the sensitivity of orthopantomography (OPT in the diagnosis of long term complications in oral rehabilitations with blade implants. Materials and methods A total of 235 blade implants in 189 patients, inserted between 1988 and 2003, were retrospectively analyzed. The records consisted of a first OPT taken between January and December 2010, and a second one 12 months after. The evaluation of implant health considered: integrity of the blade, normal radiological representation of the bone around the implant, dense and cortical appearance of bone around the implant collar. The evaluation of radiological complications considered: implant fracture, bone resorption around the implant, recession of the bone around the implant collar. Results The sensitivity of the panoramic evaluation was equal to 100%. The complications detected were 5 cases of periimplantitis, 9 cases of bone pericervical bone recession and 3 cases of fracture of the implant body. In cases of pericervical bone resorption the following radiological check up 12 months after the first one showed the progression of the disease in 6 out of 9 cases, with irreversible implant failure. In subjects with a radiological pattern of implant health there were no complications in the subsequent check up after 12 months. In the subjects with complications the specificity was equal to 100%. Conclusion The radiographic evaluation by the means of OPT has shown high sensitivity in the diagnosis of long term complications of oral rehabilitations with blade implants and allows prompt therapeutic interventions. Radiological complications appeared mostly in the long term check ups and mainly consisted in recession of the bone around the neck or around the entire implant. More rarely implant fractures occurred, which, in the case of blades, sometimes were not associated with any clinical symptoms: therefore, postsurgical evaluation should not be separated from

  3. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  4. Superior shoulder suspensory complex fracture dislocation case report

    International Nuclear Information System (INIS)

    Lidgett, T.; Bate, E.; Pittock, L.

    2017-01-01

    Background: Acromioclavicular joint dislocation can be more complex than it first appears. The presented case had an unusual combination of injuries to the superior shoulder suspensory complex, which yielded some interesting learning points. Case summary: The injuries were sustained after a fall from a push bike and included acromioclavicular dislocation with coracoid process, clavicle and acromion process fractures. These were identified on the initial X-ray examination, which was followed by computed tomography for surgical planning. The injuries were successfully treated by internal fixation. Conclusion: The unexpected complexity of the injuries could have led to subtle but important findings being overlooked. This case highlights the importance of a thorough search strategy, consideration of injury biomechanics and knowledge of associated injuries. - Highlights: • Search for associated fractures in acromioclavicular joint dislocation. • Assess the clavicle, acromion process and coracoid process in particular. • Do not end the shoulder X-ray examination after seeing one injury. • Both axial and cranially angulated anteroposterior projections are beneficial. • Acromioclavicular joint fracture dislocation treatment may require further research.

  5. The use of titanium plates for bone regeneration with root form implants: a case report.

    Science.gov (United States)

    Maksoud, M A

    1999-01-01

    In reconstruction of the partially and totally edentulous ridges that have bony defects due to old trauma or longstanding atrophy, it is necessary to reconstruct both the width and height of the alveolar ridge. This clinical case report covers bone regeneration prior to implant placement to achieve an aesthetic and functional base for prosthetic restoration. The focus of this report will be on bone regeneration, which does not depend on the utilization of a barrier membrane.

  6. The use of Osseointegration and Orbital Implants in the Management of Orbital Exenteration or Severe Contracted Sockets

    Directory of Open Access Journals (Sweden)

    Emine Esra Karaca

    2014-03-01

    Full Text Available Objectives: To evaluate the results of bony integrated implants used in the management of exenterated or contracted sockets. Materials and Methods: Ten eyes of 10 cases underwent bony integrated implants for the management of exenterated (7 eyes or contracted (3 eyes sockets. The procedure was performed in two steps in a two-month period. The first step included placement of screws by preparing the osteotomy site, whereas the second step included implantation of magnetic implants over these screws that will adhere to the orbital implant. The patients were retrospectively evaluated for age, gender, etiology, surgical timing, history of radiotherapy, and time of application of epithesis. The presence of infection at the surgical site, implant loss, functional or cosmetic problems at the perisurgical area, the usage of epithesis during the social life were evaluated. Results: There were 7 female and 3 male patients. The mean age was 34 (5-75 years. The indications for enucleation or exenteration were: retinoblastoma (4 cases, malignant melanoma (2 cases, basal cell carcinoma (1 case, squamous cell carcinoma (1 case, rhabdomyosarcoma (1 case and sinoorbital mucormycosis (1 case. The epitheses were applied 3 to 156 months (mean 51 months following the intervention. All of the implantations were performed successfully. During follow-up, one case had lost the implant and one case had local infection that responded to antibiotic treatment. Three cases were reoperated and the implants were replaced after a 2-year follow-up time due to the deterioration of the magnetic effect of the implants. Conclusion: Bony integrated orbital implants have an important role in solution of esthetic problems encountered in the exenterated orbit and severe contracted socket. (Turk J Ophthalmol 2014; 44: 127-31

  7. Basal cell carcinoma of the nipple-areola complex: a case report.

    Science.gov (United States)

    Huang, Ching-Wen; Pan, Ching-Kuen; Shih, Teng-Fu; Tsai, Cheng-Chien; Juan, Chung-Chou; Ker, Chen-Guo

    2005-10-01

    Basal cell carcinoma (BCC) of the nipple-areola complex is very rare. Only 24 cases were reported in the literature and 17 (70.8%) of these cases arose in men. Most of the cases were treated with simple excision. We report on a case of BCC of the nipple-areola complex in a 46-year-old woman, treated with partial mastectomy. Metastasis to the axillary lymph nodes had been noted in 3 (12.5%) of the 24 reported cases of BCC of the nipple-areola complex. Thus, we applied the concept of the sentinel lymph node to detect possible metastases of axillary lymph nodes, letting us avoid the unnecessary axillary lymph node dissection and possible future morbidity.

  8. Surgical pitfalls with custom-made porous hydroxyapatite cranial implants

    Directory of Open Access Journals (Sweden)

    Bruno Zanotti

    2015-03-01

    Full Text Available Aim: Cranioplasty implants are used primarily in cases of surgical cranial decompression following pathological elevations of intracranial pressure. Available bone substitutes include porous hydroxyapatite (HA and polymethylmethacrylate. Whichever material is used, however, prosthetic cranial implants are susceptible to intra- and postsurgical complications and even failure. The aim of this study was to investigate such occurrences in HA cranioplasty implants, seeking not only to determine the likely causes (whether correlated or not with the device itself but also, where possible, to suggest countermeasures. Methods: We analyzed information regarding failures or complications reported in postmarketing surveillance and clinical studies of patients treated worldwide with custom-made HA cranial implants (Custom Bone Service Fin-Ceramica Faenza, Italy in the period 1997-2013. Results: The two most common complications were implant fractures (84 cases, 2.9% of the total fitted and infections (51 cases, 1.77%. Conclusion: Although cranioplasties are superficial and not difficult types of surgery, and use of custom-made implants are often considered the "easy" option from a surgical perspective, these procedures are nonetheless plagued by potential pitfalls. If performed well they yield more than satisfactory results from the points of view of both the patient and surgeon, but lack of appropriate care can open the door to numerous potential sources of failure, which can compromise-even irreparably-the ability to heal.

  9. Moessbauer Studies of Implanted Impurities in Solids

    CERN Multimedia

    2002-01-01

    Moessbauer studies were performed on implanted radioactive impurities in semiconductors and metals. Radioactive isotopes (from the ISOLDE facility) decaying to a Moessbauer isotope were utilized to investigate electronic and vibrational properties of impurities and impurity-defect structures. This information is inferred from the measured impurity hyperfine interactions and Debye-Waller factor. In semiconductors isoelectronic, shallow and deep level impurities have been implanted. Complex impurity defects have been produced by the implantation process (correlated damage) or by recoil effects from the nuclear decay in both semiconductors and metals. Annealing mechanisms of the defects have been studied. \\\\ \\\\ In silicon amorphised implanted layers have been recrystallized epitaxially by rapid-thermal-annealing techniques yielding highly supersaturated, electrically-active donor concentrations. Their dissolution and migration mechanisms have been investigated in detail. The electronic configuration of Sb donors...

  10. Anaplastic large cell lymphoma (ALCL) and breast implants: breaking down the evidence.

    Science.gov (United States)

    Ye, Xuan; Shokrollahi, Kayvan; Rozen, Warren M; Conyers, Rachel; Wright, Penny; Kenner, Lukas; Turner, Suzanne D; Whitaker, Iain S

    2014-01-01

    Systemic anaplastic large cell lymphoma (ALCL) is a distinct disease classification provisionally sub-divided into ALCL, Anaplastic Lymphoma Kinase (ALK)(+) and ALCL, ALK(-) entities. More recently, another category of ALCL has been increasingly reported in the literature and is associated with the presence of breast implants. A comprehensive review of the 71 reported cases of breast implant associated ALCL (iALCL) is presented indicating the apparent risk factors and main characteristics of this rare cancer. The average patient is 50 years of age and most cases present in the capsule surrounding the implant as part of the periprosthetic fluid or the capsule itself on average at 10 years post-surgery suggesting that iALCL is a late complication. The absolute risk is low ranging from 1:500,000 to 1:3,000,000 patients with breast implants per year. The majority of cases are ALK-negative, yet are associated with silicone-coated implants suggestive of the mechanism of tumorigenesis which is discussed in relation to chronic inflammation, immunogenicity of the implants and sub-clinical infection. In particular, capsulotomy alone seems to be sufficient for the treatment of many cases suggesting the implants provide the biological stimulus whereas others require further treatment including chemo- and radiotherapy although reported cases remain too low to recommend a therapeutic approach. However, CD30-based therapeutics might be a future option. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2011-02-01

    Full Text Available Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant.

  12. Elective implantation of covered stents for coarctation and recoarctation in adolescents and adults.

    Science.gov (United States)

    Alcibar, Juan; Blanco, Roberto; Fernandez, Luis; Arriola, Josune; Garcia, Koldobika; Peña, Natividad; Inguanzo, Ramón; Voces, Roberto; Castellanos, Enrique; Montes, Pedro M

    2013-06-01

    Stent implantation is an effective therapy for aortic coarctation and recoarctation. However, in adolescents and adults, aortic wall rupture and dissection can occur, as well as aneurysms during follow-up. In order to reduce these complications, we electively implant covered stents. Since 2005, we have performed the procedure using femoral access in 17 patients (2 adolescents and 15 adults), 16 electively and 1 as a rescue procedure. We used the Mullins technique in all cases, implanting a NuMED(®) covered stent. Good stent apposition was achieved in all 17 procedures; 8 patients required a distal flare. Gradient was reduced from 40 (16) mmHg to 2 (2) mmHg (P<.001) and lumen diameter increased from 4 (2) mm to 19 (3) mm (P<.001). Two exceptional cases are discussed: one patient with aortic wall rupture who underwent a rescue procedure using a stent within a covered stent and another patient with total obstruction and intercostal aneurysm in whom the outcome was fatal at 48 h postprocedure (autopsy is shown). Four-year clinical follow-up included Doppler echocardiography; an additional imaging technique was required in 13 patients. All patients recovered well and there were no complications. Covered stents are effective in treating coarctation and recoarctation in adolescents and adults, are the treatment of choice in patients with complex anatomy, and must be available in the operating room as a rescue device when implanting a conventional stent. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  13. Retrospective study investigating the clinical success of two provisional implant systems

    OpenAIRE

    Hotz, Nadine

    2011-01-01

    The use of dental implants allows a reliable stabilisation of prosthesis. Usually, definitive implants can´t be used for fixation of prosthesis during their healing period. Therefore, in many cases it is not possible to follow the demand of patients of an immediate loading of definitive implants to avoid a unfixed dental prosthesis. This is one domain of provisional dental implants. The present study of two provisional implant systems approves the benefit of provisional implants during...

  14. Nueva indicación de implantes cigomáticos para la rehabilitación fija de desdentados parciales: reporte de un caso A new indication for Zygomatic implants for the fixed rehabilitation of the partially edentulous patient: Case report

    Directory of Open Access Journals (Sweden)

    M.F. Pintor Willcock

    2007-08-01

    Full Text Available Los implantes cigomáticos están indicados en casos de reabsorciones maxilares severas. Esto permitiría eliminar la necesidad de injertos óseos o levantamientos de seno de manera de recuperar el volumen óseo necesario para rehabilitar en base a implantes convencionales, disminuyendo así la morbilidad y el tiempo de tratamiento. A continuación presentamos caso de paciente desdentado parcial superior, clase I de Kennedy, en el cual se utilizaron dos implantes cigomáticos a cada lado, emergiendo sobre el reborde, a través de una modificación de la técnica.Zygomatic Implants are used in the rehabilitation of severely resorbed maxillas. This eliminates the necessity of bone grafting or sinus augmentation to restore the osseous volume necessary for conventional implant rehabilitation. This also minimizes morbidity and treatment times. We present the case of a patient with a partially edentulous upper ridge, Kennedy class I, in whom two zygomatic implants were placed in each side, that emerged over the alveolar ridge crest as a result of a technique modification.

  15. Spectroscopy of bound multi exciton complexes and deep centers in implanted and annealed silicon

    International Nuclear Information System (INIS)

    Babich, V.M.; Valakh, M.Ya.; Kovalchuk, V.B.; Rudko, G.Yu.; Shakhrajchuk, N.I.

    1989-01-01

    The change of silicon properties relevant to device physics caused by ion implantation and thermal annealing is studied. It is shown that in boron-doped p-Si the increase of P + ions implantation doses from 10 12 to 10 14 ions/cm 2 lead to a decrease of the broadening of boron bound exciton bands. This behaviour is caused by implantation-induced disordering of the lattice. The subsequent thermal annealing restores the intensity and the halfwidth of the above-mentioned bands and initiates the increase of the bands which correspond to excitons bond on the implanted phosphorus ions. Measurements of phosphorus bound exciton band intensities are applicable to the characterization of the process of phosphorus activation. Analysis of low energy region of luminescence spectra of heat treated samples shows that there is a correlation between the process of implanted phosphorus activation and the one of radiation defects transformation. The influence of germanium doping on the generation of thermal donors by means of spectroscopy of deep centres luminescence has been investigated. It is shown that the introduction of germanium in concentrations of 10 19 -10 20 cm -3 effectively suppresses the generation of thermal donors and deep centres under investigation. (author)

  16. Plasma Immersion Ion Implantation in Radio Frequency Plasma

    International Nuclear Information System (INIS)

    Bora, B.; Bhuyan, H.; Wyndham, E.

    2013-01-01

    Plasma immersion ion implantation (PIII) has attracted wide interests since it emulates conventional ion-beam ion implantation (IBII) in niche applications. For instance, the technique has very high throughput, the implantation time is independent of the sample size, and samples with an irregular shape can be implanted without complex beam scanning or sample manipulation. For uniform ion implantation and deposition on to different substrates, like silicon, stainless steel etc., a capacitive coupled Radio frequency (RF), 13.6 MHz, plasma is used. During the PIII process, the physical parameters which are expected to play crucial rule in the deposition process like RF power, Negative pulse voltage and pulse duration, gas type and gas mixture, gas flow rates and the implantation dose are studied. The ion dose is calculated by dynamic sheath model and the plasma parameters are calculated from the V-I characteristic and power balance equation by homogeneous model of rf plasma discharge considering Ohmic as well as Stochastic heating. The correlations between the yield of the implantation process and the physical parameters as well as plasma parameters are discussed. (author)

  17. Risk of lymphoma in women with breast implants: analysis of clinical studies.

    Science.gov (United States)

    Largent, Joan; Oefelein, Michael; Kaplan, Hilton M; Okerson, Ted; Boyle, Peter

    2012-05-01

    Large studies suggest that the overall rate of lymphoma in women with breast implants is no greater than in the general population; clinical reports suggest an association between breast implants and the rare non-Hodgkin lymphoma, anaplastic large cell lymphoma (ALCL). Observed cases of lymphoma reported in Allergan-sponsored breast implant clinical studies were compared with expected cases on the basis of the incidence of lymphoma among women in the National Cancer Institute's Surveillance Epidemiology and End Results program, using standardized incidence ratios (SIRs) and 95% confidence intervals (CIs). In clinical studies, there were 28 observed cases of lymphoma among 89 382 patients and 204 682 person-years of follow-up compared with 43 expected cases [SIR: 28/43=0.65 (95% CI: 0.43-0.94), P=0.02]. SIRs were calculated stratifying by baseline cancer history: women without prior cancer [SIR: 17/24=0.70 (95% CI: 0.41-1.13), P=0.17] and women with prior cancer [SIR: 11/14=0.79 (95% CI: 0.39-1.41), P=0.52]. SIRs were calculated by implant shell type: textured shell implants [SIR: 16/23=0.70 (95% CI: 0.40-1.13), P=0.16] and smooth shell implants [SIR: 12/19=0.63 (95% CI: 0.33-1.10), P=0.12]. Surveillance Epidemiology and End Results reported 12 cases of primary breast ALCL in women between 1996 and 2007 without a history of cancer, for an average annual incidence of 4.28 (95% CI: 3.51-5.05)/100 million women in the US - these women may or may not have breast implants. In clinical studies, three ALCL cases were reported in women with breast implants and a history of breast cancer, yielding a crude incidence rate of 1.46 (95% CI: 0.30-4.3)/100 000 person-years. Large clinical studies, based on over 200 000 person-years of follow-up, suggest no evidence of an increased risk of lymphoma among women who have received breast implants.

  18. Purposeful exposure of a polylactic acid barrier to achieve socket preservation for placement of dental implants: case series report.

    Science.gov (United States)

    Rosen, Paul S; Rosen, Adam D

    2013-01-01

    This retrospective case series reports on the use of a polylactic acid barrier that was left exposed in the process of socket preparation for the placement of dental implants. A retrospective chart review found 43 patients with 48 extraction sockets that were treated in this manner. Teeth were removed and the sockets were thoroughly debrided, with 40 of them receiving a bone replacement graft covered by the polylactic acid barrier and the additional 8 receiving the membrane alone. Suturing left the barrier exposed, and the sites were re-entered on average at 23 weeks for the placement of a dental implant. All sites were able to receive a dental implant, demonstrating the ability to leave a polylactic acid barrier exposed and achieve successful guided bone regeneration (GBR) results. This ultimately helped avoid some of the negative sequelae of trying to achieve primary closure of the flaps at the time of tooth extraction.

  19. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants

    Science.gov (United States)

    Du, Jing; Lee, Jihyun; Jang, Andrew; Gu, Allen; Hossaini-Zadeh, Mehran; Prevost, Richard; Curtis, Don; Ho, Sunita

    2015-01-01

    The effects of alveolar bone socket geometry and bone-implant contact on implant biomechanics, and resulting strain distributions in bone were investigated. Following extraction of lateral incisors on a cadaver mandible, immediate implants were placed and bone-implant contact area, stability and bone strain were measured. In situ biomechanical testing coupled with micro X-ray microscope (μ-XRM) illustrated less stiff bone-implant complexes (701-822 N/mm) compared with bone-periodontal ligament (PDL)-tooth complexes (791-913 N/mm). X-ray tomograms illustrated that the cause of reduced stiffness was due to reduced and limited bone-implant contact. Heterogeneous elemental composition of bone was identified by using energy dispersive X-ray spectroscopy (EDS). The novel aspect of this study was the application of a new experimental mechanics method, that is, digital volume correlation, which allowed mapping of strains in volumes of alveolar bone in contact with a loaded implant. The identified surface and subsurface strain concentrations were a manifestation of load transferred to bone through bone-implant contact based on bone-implant geometry, quality of bone, implant placement, and implant design. 3D strain mapping indicated that strain concentrations are not exclusive to the bone-implant contact regions, but also extend into bone not directly in contact with the implant. The implications of the observed strain concentrations are discussed in the context of mechanobiology. Although a plausible explanation of surgical complications for immediate implant treatment is provided, extrapolation of results is only warranted by future systematic studies on more cadaver specimens and/or in vivo small scale animal models. PMID:26162549

  20. A hot implantation study on the evolution of defects in He ion implanted MgO(1 0 0)

    International Nuclear Information System (INIS)

    Fedorov, A.V.; Huis, M.A. van; Veen, A. van

    2002-01-01

    Ion implantation at elevated temperature, so-called hot implantation, was used to study nucleation and thermal stability of the defects. In this work, MgO(1 0 0) single crystal samples were implanted with 30 keV He ions at various implantation temperatures. The implantation doses ranged from 10 14 to 10 16 cm -2 . The implantation introduced defects were subsequently studied by thermal helium desorption spectroscopy (THDS) and Doppler broadening positron beam analysis (PBA). The THDS study provides vital information on the kinetics of He release from the sample. PBA technique, being sensitive to the open volume defects, provides complementary information on cavity evolution. The THD study has shown that in most cases helium release is characterised by the activation energy of Q=4.7±0.5 eV with the maximum release temperature of T max =1830 K. By applying first order desorption model the pre-exponent factor is estimated as ν=4.3x10 11 s -1

  1. Use of SIG device to accurately place permanent miniature dental implants to retain mandibular overdenture. A case report.

    Science.gov (United States)

    Sussman, Harold I; Goodridge, Opal F

    2006-01-01

    A case of mini-dental implant insertion for retention of a mandibular overdenture in a hospitalized patient has been documented. The additional use of the SIG (drill guide) directional device in the implant placement protocol gave the practitioner more confidence and resulted in the proper alignment of the three ball-top, one-piece fixtures. The three implants were inserted exactly 1 cm apart and parallel to each other. The distal fixtures were approximately 1 cm away from the mental foramina, thereby eliminating the risk of lip paresthesia. Keeper caps were placed in the denture's intaglio after one month. The keeper caps allowed for proper retention of the overdenture. The caps also enabled the patient to easily insert and withdraw his denture, even though he displayed limited manual dexterity. The tissue response was excellent, and oral hygiene was made easier with adequate spacing of the exposed ball-tops. The overall experience for both the operator and the patient was very positive. General dentists should be able to readily master this technique and add it to their armamentarium for the benefit of all their patients.

  2. Implantation of 3D-Printed Patient-Specific Aneurysm Models into Cadaveric Specimens: A New Training Paradigm to Allow for Improvements in Cerebrovascular Surgery and Research

    Directory of Open Access Journals (Sweden)

    Arnau Benet

    2015-01-01

    Full Text Available Aim. To evaluate the feasibility of implanting 3D-printed brain aneurysm model in human cadavers and to assess their utility in neurosurgical research, complex case management/planning, and operative training. Methods. Two 3D-printed aneurysm models, basilar apex and middle cerebral artery, were generated and implanted in four cadaveric specimens. The aneurysms were implanted at the same anatomical region as the modeled patient. Pterional and orbitozygomatic approaches were done on each specimen. The aneurysm implant, manipulation capabilities, and surgical clipping were evaluated. Results. The 3D aneurysm models were successfully implanted to the cadaveric specimens’ arterial circulation in all cases. The features of the neck in terms of flexibility and its relationship with other arterial branches allowed for the practice of surgical maneuvering characteristic to aneurysm clipping. Furthermore, the relationship of the aneurysm dome with the surrounding structures allowed for better understanding of the aneurysmal local mass effect. Noticeably, all of these observations were done in a realistic environment provided by our customized embalming model for neurosurgical simulation. Conclusion. 3D aneurysms models implanted in cadaveric specimens may represent an untapped training method for replicating clip technique; for practicing certain approaches to aneurysms specific to a particular patient; and for improving neurosurgical research.

  3. Automated Implanter Endstation for Combinatorial Materials Science with Ion Beams

    International Nuclear Information System (INIS)

    Grosshans, I.; Karl, H.; Stritzker, B.

    2003-01-01

    The discovery, understanding and optimization of new complex functional materials requires combinatorial synthesis techniques and fast screening instrumentation for the measurement of the samples. In this contribution the synthesis of buried II-VI compound semiconductor nanocrystals by ion-implantation in SiO2 on silicon will be presented. For that we constructed a computer controlled implanter target end station, in which a 4-inch wafer can be implanted with a lateral pattern of distinct dose, composition or energy combinations. The chemical reaction of the constituents is initiated either during the implantation process or ex-situ by a rapid thermal process, where a reactive atmosphere can be applied. The resulting optical photoluminescence properties of the individual fields of the pattern can then be screened in rapid succession in an optical cryostat into which the whole wafer is mounted and cooled down. In this way, complex interdependences of the physical parameters can be studied on a single wafer and the technically relevant properties optimized

  4. Tuberous sclerosis complex: A case report

    Directory of Open Access Journals (Sweden)

    Soumyabrata Sarkar

    2016-01-01

    Full Text Available Tuberous sclerosis complex is an unusual autosomal dominant neurocutaneous syndrome characterized by the development of benign tumors affecting different body systems affecting the brain, skin, retina, and viscera. It is characterized by cutaneous changes, neurologic conditions, and the formation of hamartomas in multiple organs leading to morbidity and mortality. The most common oral manifestations are fibromas, gingival hyperplasia, and enamel hypoplasia. The management of these patients is often multidisciplinary involving specialists from various fields. Here, we present a case report of a 26-old-year male patient with characteristic clinical, radiological, and histological features of tuberous sclerosis complex.

  5. Uso do implante esférico Medpor ™: análise de 61 cirurgias orbitárias Use of Medpor ™ spherical implant: analysis of 61 orbital surgeries

    Directory of Open Access Journals (Sweden)

    Eurípedes da Mota Moura

    2007-02-01

    Full Text Available OBJETIVO: Analisar o uso do implante biointegrável Medpor™ em cirurgias de evisceração, enucleação ou implantação secundária em cavidades anoftálmicas. MÉTODOS: Em 61 cirurgias foi utilizado o implante orbitário Medpor™ . Em 18 casos de evisceração, não houve necessidade do revestimento do implante. Em 12 cirurgias de enucleação e implantação secundária o material utilizado para revestir o implante foi duramater homóloga. Nas demais 31 cirurgias, o revestimento foi de material autólogo (esclera, derme, músculo orbicular ou cartilagem auricular, utilizando-se a técnica de "solidéu", recobrindo apenas a superfície anterior do Medpor ™ . RESULTADOS: Os pacientes foram operados no período de janeiro/1998 a dezembro/2004, com tempo de seguimento médio de 30 meses. Em todos os casos houve aceitação do implante, permitindo boa adaptação da prótese. Em dois pacientes ocorreu exposição tardia do implante: o primeiro caso foi corrigido pelo reposicionamento do implante na cavidade, e no segundo caso a exposição foi coberta com um retalho de tarso. CONCLUSÕES: Na nossa experiência o implante Medpor ™ apresenta boa aceitação com taxa de exposição pequena do mesmo (apenas 2 casos, nenhum caso de infecção ou migração, e boa adaptação da prótese em todos os pacientes. O uso de tecido autólogo para revestir a superfície anterior do implante elimina o risco inerente ao uso de tecidos homólogos.PURPOSE: To analyze the use of Medpor ™ biointegrated implant in surgeries of evisceration, enucleation or secondary implantation in anophthalmic sockets. METHODS: The Medpor™ orbitary implant was used in 61 surgeries. In 18 cases of evisceration the implant's wrapping was not necessary. In 12 enucleation and secondary implantation surgeries the utilized material to wrap the implant was homologous duramater. In the other 31 surgeries, the implant wrapping was made from autologous tissue (sclera, dermis

  6. A New Look at Worst Case Complexity: A Statistical Approach

    Directory of Open Access Journals (Sweden)

    Niraj Kumar Singh

    2014-01-01

    Full Text Available We present a new and improved worst case complexity model for quick sort as yworst(n,td=b0+b1n2+g(n,td+ɛ, where the LHS gives the worst case time complexity, n is the input size, td is the frequency of sample elements, and g(n,td is a function of both the input size n and the parameter td. The rest of the terms arising due to linear regression have usual meanings. We claim this to be an improvement over the conventional model; namely, yworst(n=b0+b1n+b2n2+ɛ, which stems from the worst case O(n2 complexity for this algorithm.

  7. Implante intra-ocular de lentes dobráveis "piggyback" em paciente portador de catarata congênita no primeiro ano de vida: relato de caso Piggyback foldable intraocular lens implant in patient with congenital cataract in the first year of life: case report

    Directory of Open Access Journals (Sweden)

    Leonardo Akaishi

    2004-12-01

    Full Text Available No presente relato os autores descrevem um caso de catarata congênita unilateral tratada cirurgicamente com implante intra-ocular de lentes dobráveis "piggyback", ainda não descrito na literatura nacional. São analisadas as diferenças e semelhanças com outros casos descritos na literatura.The authors report a case of congenital cataract, which was treated with piggyback foldable intraocular lens implant, not described in the Brazilian literature. The differences and similarities are analyzed with other reported cases in the literature.

  8. Estimation of efficiency of new local rehabilitation method at the early post-operative period after dental implantation

    Directory of Open Access Journals (Sweden)

    A. V. Pasechnik

    2017-01-01

      Summary Despite of success of dental implantation, there are often complications at the early post-operative period of implant placing associated with wound damage and aseptic inflammation. Purpose of the work is studying clinical efficiency of combined local application of new mucosal gel “Apior” and magnetotherapy at the early post-operative period after dental implantation. Combined local application of the mucosal gel “Apior” and pulsating low-frequency electromagnetic field in the complex medical treatment of patients after conducting an operation of setting dental implants favourably affects the common state of patients and clinical symptoms of inflammation in the area of operating wound. As compared with patients who had traditional anti-inflammatory therapy, the patients treated with local application of apigel and magnetoterapy had decline of edema incidence, of gingival mucosa hyperemia, of discomfort in the area of conducted operation. There occurred more rapid improvement of inflammation painfulness, which correlated with the improvement of hygienic state of oral cavity and promoted to prevention of bacterial content of damaged mucous surfaces. Estimation of microvasculatory blood stream by the method of ultrasonic doppler flowmetry revealed more rapid normalization of volume and linear high systole speed of blood stream in the periimplant tissues in case of use of new complex local rehabilitation method, that testified to the less pronounced inflammation of oral mucosa after the operation. The authors came to conclusion that the local application of the offered method of medical treatment of early post-operative complications of dental implantation reduces terms of renewal of structural-functional integrity of oral mucosa, helps in preventing development of inflammatory complications and strengthening endosseus implant. The inclusion in the treatment management of a new combined method of application of mucosal gel “Apior” and

  9. Microcomputed tomography-based assessment of retrieved dental implants

    NARCIS (Netherlands)

    Narra, N.; Antalainen, A.K.; Zipprich, H.; Sándor, G.K.; Wolff, J.

    2015-01-01

    Purpose: The aim of this study was to demonstrate the potential of microcomputed tomography (micro-CT) technology in the assessment of retrieved dental implants. Cases are presented to illustrate the value of micro-CT imaging techniques in determining possible mechanical causes for dental implant

  10. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    KAUST Repository

    Jain, Harsh Vardhan

    2012-07-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O(2)) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O(2)-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O(2) pressure (pO(2)) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO(2) to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases.

  11. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    KAUST Repository

    Jain, Harsh Vardhan; Moldovan, Nicanor I.; Byrne, Helen M.

    2012-01-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O(2)) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O(2)-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O(2) pressure (pO(2)) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO(2) to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases.

  12. Modeling Stem/Progenitor Cell-Induced Neovascularization and Oxygenation Around Solid Implants

    Science.gov (United States)

    Moldovan, Nicanor I.; Byrne, Helen M.

    2012-01-01

    Tissue engineering constructs and other solid implants with biomedical applications, such as drug delivery devices or bioartificial organs, need oxygen (O2) to function properly. To understand better the vascular integration of such devices, we recently developed a novel model sensor containing O2-sensitive crystals, consisting of a polymeric capsule limited by a nanoporous filter. The sensor was implanted in mice with hydrogel alone (control) or hydrogel embedded with mouse CD117/c-kit+ bone marrow progenitor cells in order to stimulate peri-implant neovascularization. The sensor provided local partial O2 pressure (pO2) using noninvasive electron paramagnetic resonance signal measurements. A consistently higher level of peri-implant oxygenation was observed in the cell-treatment case than in the control over a 10-week period. To provide a mechanistic explanation of these experimental observations, we present in this article a mathematical model, formulated as a system of coupled partial differential equations, that simulates peri-implant vascularization. In the control case, vascularization is considered to be the result of a foreign body reaction, while in the cell-treatment case, adipogenesis in response to paracrine stimuli produced by the stem cells is assumed to induce neovascularization. The model is validated by fitting numerical predictions of local pO2 to measurements from the implanted sensor. The model is then used to investigate further the potential for using stem cell treatment to enhance the vascular integration of biomedical implants. We thus demonstrate how mathematical modeling combined with experimentation can be used to infer how vasculature develops around biomedical implants in control and stem cell-treated cases. PMID:22224628

  13. Facial and occlusal esthetic improvements of an adult skeletal Class III malocclusion using surgical, orthodontic, and implant treatment

    Science.gov (United States)

    de Almeida Cardoso, Mauricio; de Avila, Erica Dorigatti; Guedes, Fabio Pinto; Battilani Filho, Valter Antonio Ban; Capelozza Filho, Leopoldino; Correa, Marcio Aurelio; Nary Filho, Hugo

    2016-01-01

    The aim of this clinical report is to describe the complex treatment of an adult Class III malocclusion patient who was disappointed with the outcome of a previous oral rehabilitation. Interdisciplinary treatment planning was performed with a primary indication for implant removal because of marginal bone loss and gingival recession, followed by orthodontic and surgical procedures to correct the esthetics and skeletal malocclusion. The comprehensive treatment approach included: (1) implant removal in the area of the central incisors; (2) combined orthodontic decompensation with mesial displacement and forced extrusion of the lateral incisors; (3) extraction of the lateral incisors and placement of new implants corresponding to the central incisors, which received provisional crowns; (4) orthognathic surgery for maxillary advancement to improve occlusal and facial relationships; and finally, (5) orthodontic refinement followed by definitive prosthetic rehabilitation of the maxillary central incisors and reshaping of the adjacent teeth. At the three-year follow-up, clinical and radiographic examinations showed successful replacement of the central incisors and improved skeletal and esthetic appearances. Moreover, a Class II molar relationship was obtained with an ideal overbite, overjet, and intercuspation. In conclusion, we report the successful esthetic anterior rehabilitation of a complex case in which interdisciplinary treatment planning improved facial harmony, provided gingival architecture with sufficient width and thickness, and improved smile esthetics, resulting in enhanced patient comfort and satisfaction. This clinical case report might be useful to improve facial esthetics and occlusion in patients with dentoalveolar and skeletal defects. PMID:26877982

  14. Biocompatibility of Advanced Manufactured Titanium Implants-A Review.

    Science.gov (United States)

    Sidambe, Alfred T

    2014-12-19

    Titanium (Ti) and its alloys may be processed via advanced powder manufacturing routes such as additive layer manufacturing (or 3D printing) or metal injection moulding. This field is receiving increased attention from various manufacturing sectors including the medical devices sector. It is possible that advanced manufacturing techniques could replace the machining or casting of metal alloys in the manufacture of devices because of associated advantages that include design flexibility, reduced processing costs, reduced waste, and the opportunity to more easily manufacture complex or custom-shaped implants. The emerging advanced manufacturing approaches of metal injection moulding and additive layer manufacturing are receiving particular attention from the implant fabrication industry because they could overcome some of the difficulties associated with traditional implant fabrication techniques such as titanium casting. Using advanced manufacturing, it is also possible to produce more complex porous structures with improved mechanical performance, potentially matching the modulus of elasticity of local bone. While the economic and engineering potential of advanced manufacturing for the manufacture of musculo-skeletal implants is therefore clear, the impact on the biocompatibility of the materials has been less investigated. In this review, the capabilities of advanced powder manufacturing routes in producing components that are suitable for biomedical implant applications are assessed with emphasis placed on surface finishes and porous structures. Given that biocompatibility and host bone response are critical determinants of clinical performance, published studies of in vitro and in vivo research have been considered carefully. The review concludes with a future outlook on advanced Ti production for biomedical implants using powder metallurgy.

  15. Anterior migration of dexamethasone implant in a pseudophakic patient with intact posterior capsule

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available Intravitreal application of Ozurdex ® (Allergan, Inc., Irvine, CA, USA which is a biodegradable, sustained-release dexamethasone implant has been reported to be effective in the treatment of macular edema. Migration of such implant into the anterior chamber has been recently described in cases without perfect zonular or the posterior capsular integrity. Herein, we report the first case with anterior migration of Ozurdex ® implant that mislocated just behind the intraocular lens (IOL in an intact capsular bag. It is thought that such implant migrated anteriorly towards into the posterior chamber through weak zonules as the present case had a medical history of uneventful phacoemulsification surgery with the implantation of posterior chamber IOL. However, the migrated implant was well tolerated since there was no sign of the corneal complication, rise in intraocular pressure, and anterior chamber reaction. Close follow-up was scheduled to find out any signs of anterior segment pathology. Meanwhile dexamethasone implant completely degraded at the 4 th month of postoperative follow-up.

  16. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  17. [Cochlear implantation through the middle fossa approach].

    Science.gov (United States)

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  18. Laser microtexturing of implant surfaces for enhanced tissue integration

    Energy Technology Data Exchange (ETDEWEB)

    Ricci, J.L. [Univ. of Medicine and Dentistry of New Jersey, Newark, NJ (United States). Dept. of Orthodontics; Alexander, H. [Orthogen Corp., Springfield, NJ (United States)

    2001-07-01

    The success or failure of bone and soft tissue-fixed medical devices, such as dental and orthopaedic implants, depends on a complex combination of biological and mechanical factors. These factors are intimately associated with the interface between the implant surface and the surrounding tissue, and are largely determined by the composition, surface chemistry, and surface microgeometry of the implant. The relative contributions of these factors are difficult to assess. This study addresses the contribution of surface microtexture, on a controlled level, to tissue integration. (orig.)

  19. Los implantes MG-OSSEOUS: Estudio multicéntrico retrospectivo MG-OSSEOUS implants: A multicentric retrospective study

    Directory of Open Access Journals (Sweden)

    E. Serrano Caturla

    2006-12-01

    commercial implants. Material and methodology. This is a retrospective multicentric study coordinated by a company called Scientific Management in O&SS (Barcelona, Spain. 1001 dental implants were placed in 247 patients and 328 prostheses were designed between 2004 and 2005, with a follow-up of two years. All implants were loaded with prostheses. We detail and analyze each implant, according to the diameter, length, position, surgical timing, loadings, design and types of prostheses and complementary surgical procedures, either synchronic or metachronic. Results. After the statistical method was homogenized, we were able to report an overall implant survival rate of 97.8% with monitoring of two years. The failures depending on the peculiarities of each clinical case are provided. No prosthetic failures are reported. Discussion. The criteria and indications applied by the professionals to the MG-OSSEOUS implants are standardized depending on the clinical case. Our results are compared with the international scientific literature, past and present, with these procedures totally agreeing with those found in the history of implantology. Finally, our survey is compared with those published by the Branemark team. Conclusion. The mixture between the quality of the MGOSSEOUS implants and the scientifically supported criteria regarding the implants, reveals an implant failure of 2.2% over two years, with a survival of 100% of both the replaced implants and the loaded prostheses.

  20. [Application of endosseous screw implants. Indications and planning].

    Science.gov (United States)

    Pajarola, G F; Sailer, H F

    1991-01-01

    To achieve long term positive results for endosseous dental implants, three points have to be considered: the osséointegration, the correct indication and the suprastructural planification designed for the spécific type of implant. If the surgery part is done by a different practitioner as the prosthetic part, tight coworking for planning is necessary and the responsibility in each step has to be cleared in advance. The planification in implant cases is divided into three stages: clearing of contraindications, choice of the suprastructure, and the surgery planning. Aids for exact localisation of the implants are presented.

  1. Erupting complex odontoma: Report of a rare case

    Directory of Open Access Journals (Sweden)

    Pinakapani Ramakrishna

    2014-01-01

    Full Text Available Odontomas are the most frequent hamartomatous lesions involving the oral cavity. The complex variant is an agglomerate of all dental tissues characterized by abnormal morphodifferentiation despite normal histodifferentiation. These are usually asymptomatic and are frequently associated with eruption disturbances. We report an unusual case of erupting complex odontoma associated with an impacted maxillary second molar.

  2. Stratification of risk to the surgical team in removal of small arms ammunition implanted in the craniofacial region: case report.

    Science.gov (United States)

    Forbes, Jonathan A; Laughlin, Ian; Newberry, Shane; Ryhn, Michael; Pasley, Jason; Newberry, Travis

    2016-09-01

    In cases of penetrating injury with implantation of small arms ammunition, it can often be difficult to tell the difference between simple ballistics and ballistics associated with unexploded ordnances (UXOs). In the operative environment, where highly flammable substances are often close to the surgical site, detonation of UXOs could have catastrophic consequences for both the patient and surgical team. There is a paucity of information in the literature regarding how to evaluate whether an implanted munition contains explosive material. This report describes a patient who presented during Operation Enduring Freedom with an implanted munition suspicious for a UXO and the subsequent workup organized by Explosive Ordnance Disposal (EOD) Company prior to surgical removal. Clinical risk factors for UXOs include assassination attempts and/or wartime settings. Specific radiological features suggestive of a UXO include projectile size greater than 7.62-mm caliber, alterations in density of the tip, as well as radiological evidence of a hollowed-out core. If an implanted UXO is suspected, risks to the surgical and anesthesia teams can be minimized by notifying the nearest military installation with EOD capabilities and following clinical practice guidelines set forth by the Joint Theater Trauma System.

  3. Bacterial Meningitis after Cochlear Implantation among Children without Polyvalent Conjugate Vaccine: A Brief Report of an Iranian Cohort Study on 371 Cases

    Directory of Open Access Journals (Sweden)

    Shahla Afsharpaiman

    2014-01-01

    Full Text Available Background: Regarding risk of bacterial meningitis (BM after Cochlear implantation (CI, it was suggested to receive polyvalent conjugate vaccine. We aimed to estimate the prevalence of BM post CI in child recipients who do not receive polyvalent vaccine. Methods: We enrolled 371 children who had received cochlear implants from 2007 to 2010. None of them received pre or post implantation polyvalent conjugate vaccine for BM. We followed all of them for BM for 2 years after implantation. Results: We detected only one female case of BM (0.3% of patients with the age of 24 months. The mean age of noninfected children was 36.7 ± 23.2 months. The education level of parents was "college level or higher" in less than half of them, and about 65% of patients were products of consanguineous marriage. Conclusions: Our findings indicated that the incidence of BM was not higher in our cochlear implanted children who did not receive immunization than patients from countries in which routine vaccination is done. We suggest that although proper immunization is recommended before surgery, this procedure could be performed without vaccination, especially in developing countries that face financial problems for preparing vaccines.

  4. Long-term Survival of Straumann Dental Implants with TPS Surfaces: A Retrospective Study with a Follow-up of 12 to 23 Years.

    Science.gov (United States)

    Becker, Stephan T; Beck-Broichsitter, Benedicta E; Rossmann, Christian M; Behrens, Eleonore; Jochens, Arne; Wiltfang, Jörg

    2016-06-01

    The aim of this study was to evaluate the long-term dental implant survival rates of Straumann dental implants in a university hospital environment over 12 to 23 years. A total of 388 Straumann dental implants with titanium-sprayed surfaces (TPS) were inserted in 92 patients between 1988 and 1999 in the Department of Oral and Maxillofacial Surgery of the University Hospital Schleswig-Holstein in Kiel, and they were reevaluated with standardized clinical and radiological exams. Kaplan-Meier analyses were performed for individual factors. Cox proportional hazard regression analysis was used to detect the factors influencing long-term implant failure. The long-term implant survival rate was 88.03% after an observation time of 12.2 to 23.5 years. Cox regression revealed statistically significant influences of the International Team for Implantology (ITI) implantation type (p = .00354) and tobacco smoking (p = .01264) on implant failure. A proportion 82.8% of the patients with implant losses had a medical history of periodontitis. Peri-implantitis was diagnosed in 9.7% of the remaining implants in the long-term survey. This study emphasized the long-term rehabilitation capabilities of Straumann dental implants in complex cases. The survival rates after several years constitute important information for patients, as well as for clinicians, in deciding about different concepts of tooth replacement. Patient-related and technical factors - determined before implant placement - could help to predict the risk of implant loss. © 2015 Wiley Periodicals, Inc.

  5. Do breast implants after a mastectomy affect subsequent prognosis and survival?

    OpenAIRE

    Brinton, Louise A

    2005-01-01

    In a large study, published in this issue of Breast Cancer Research, Le and colleagues report that women receiving implants after mastectomies for early-stage breast cancer experience lower breast cancer mortality than women not receiving implants. Assessment of survival patterns among women receiving reconstructive implants is complex given unique patient characteristics, disease attributes, and treatment patterns. The interpretation of reduced mortality from breast cancer must be assessed i...

  6. Interaction of mobile phones with superficial passive metallic implants

    International Nuclear Information System (INIS)

    Virtanen, H; Huttunen, J; Toropainen, A; Lappalainen, R

    2005-01-01

    The dosimetry of exposure to radiofrequency (RF) electromagnetic (EM) fields of mobile phones is generally based on the specific absorption rate (SAR, W kg -1 ), which is the electromagnetic energy absorbed in the tissues per unit mass and time. In this study, numerical methods and modelling were used to estimate the effect of a passive, metallic (conducting) superficial implant on a mobile phone EM field and especially its absorption in tissues in the near field. Two basic implant models were studied: metallic pins and rings in the surface layers of the human body near the mobile phone. The aim was to find out 'the worst case scenario' with respect to energy absorption by varying different parameters such as implant location, orientation, size and adjacent tissues. Modelling and electromagnetic field calculations were carried out using commercial SEMCAD software based on the FDTD (finite difference time domain) method. The mobile phone was a 900 MHz or 1800 MHz generic phone with a quarter wave monopole antenna. A cylindrical tissue phantom models different curved sections of the human body such as limbs or a head. All the parameters studied (implant size, orientation, location, adjacent tissues and signal frequency) had a major effect on the SAR distribution and in certain cases high local EM fields arose near the implant. The SAR values increased most when the implant was on the skin and had a resonance length or diameter, i.e. about a third of the wavelength in tissues. The local peak SAR values increased even by a factor of 400-700 due to a pin or a ring. These highest values were reached in a limited volume close to the implant surface in almost all the studied cases. In contrast, without the implant the highest SAR values were generally reached on the skin surface. Mass averaged SAR 1g and SAR 10g values increased due to the implant even by a factor of 3 and 2, respectively. However, at typical power levels of mobile phones the enhancement is unlikely to be

  7. The Effect of Price on Surgeons' Choice of Implants: A Randomized Controlled Survey.

    Science.gov (United States)

    Wasterlain, Amy S; Melamed, Eitan; Bello, Ricardo; Karia, Raj; Capo, John T

    2017-08-01

    Surgical costs are under scrutiny and surgeons are being held increasingly responsible for cost containment. In some instances, implants are the largest component of total procedure cost, yet previous studies reveal that surgeons' knowledge of implant prices is poor. Our study aims to (1) understand drivers behind implant selection and (2) assess whether educating surgeons about implant costs affects implant selection. We surveyed 226 orthopedic surgeons across 6 continents. The survey presented 8 clinical cases of upper extremity fractures with history, radiographs, and implant options. Surgeons were randomized to receive either a version with each implant's average selling price ("price-aware" group), or a version without prices ("price-naïve" group). Surgeons selected a surgical implant and ranked factors affecting implant choice. Descriptive statistics and univariate, multivariable, and subgroup analyses were performed. For cases offering implants within the same class (eg, volar locking plates), price-awareness reduced implant cost by 9% to 11%. When offered different models of distal radius volar locking plates, 25% of price-naïve surgeons selected the most expensive plate compared with only 7% of price-aware surgeons. For cases offering different classes of implants (eg, plate vs external fixator), there was no difference in implant choice between price-aware and price-naïve surgeons. Familiarity with the implant was the most common reason for choosing an implant in both groups (35% vs 46%). Price-aware surgeons were more likely to rank cost as a factor (29% vs 21%). Price awareness significantly influences surgeons' choice of a specific model within the same implant class. Merely including prices with a list of implants leads surgeons to select less expensive implants. This implies that an untapped opportunity exists to reduce surgical expenditures simply by enhancing surgeons' cost awareness. Economic/Decision Analyses I. Copyright © 2017 American

  8. Placement of fin type dental implant in three different surgical situations of alveolar bone

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2007-03-01

    Full Text Available Three different dental implant placements according to surgical implant bed situations were observed in its bone integration 3 months after dental implant insertion. This observation was done on implant system which has plateau or fin system. Elf implants were placed in the upper jaw in two patients. In case one, two implants were inserted immediately after tooth extraction, and the other six implants were placed in the alveolar crest regions in delayed implantation or in which the teeth had been extracted over 6 months of period. In case two, three implants were inserted in the post trauma region in the anterior maxilla, which the labial plate had been lost and reconstructed with bone grafting procedure using a mixture of alloplastic and autogenous bones. The alveolar reconstruction was needed to be performed due to only thin alveolar crest width was left intact. All of those implants observed showed in good integration.

  9. A comparison in cosmetic outcome between per-operative interstitial breast implants and delayed interstitial breast implants after external beam radiotherapy

    International Nuclear Information System (INIS)

    Pieters, Bradley R.; Hart, Augustinus A.M.; Russell, Nicola S.; Jansen, Edwin P.M.; Peterse, Johannes L.; Borger, Jacques; Rutgers, Emiel J.Th.

    2003-01-01

    Background and purpose: Interstitial implants for brachytherapy boost in the breast conserving therapy of breast cancer can be performed in two ways; implants during the tumor excision (per-operative implants) or after the external beam therapy (delayed interstitial implants). Differences in cosmetic outcome were investigated. Patients and methods: Cosmetic results in 47 patients having a per-operative implant were compared to 123 patients having a delayed interstitial implant in a matched case-control study. Cosmesis was scored on a four-point-scale varying from 0 (excellent) to 3 (poor). Results: After mean follow-up of 63 months, three observers found no difference in cosmetic outcome between the two groups after adjustment for variables found to be related with cosmesis (difference in mean score 0.50, P=0.26). Implant volume at 100% isodose was not found to differ (P=0.084) between the per-operative group (mean 102 cm 3 , S.D. 34 cm 3 ) and the delayed group (mean 93 cm 3 , S.D. 29 cm 3 ). Conclusions: Performing per-operative implants has not led to smaller implants. The method of performing brachytherapy does not result in marked differences in cosmetic outcome

  10. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    Science.gov (United States)

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. High energy P implants in silicon

    International Nuclear Information System (INIS)

    Raineri, V.; Cacciato, A.; Benyaich, F.; Priolo, F.; Rimini, E.; Galvagno, G.; Capizzi, S.

    1992-01-01

    Phosphorus ions in the energy range 0.25-1 MeV and in the dose range 2x10 13 -1x10 15 P/cm 2 were implanted into (100) Si single crystal at different tilt angles. In particular channeling and random conditions were investigated. For comparison some implants were performed on samples with a 2 μm thick surface amorphous layer. Chemical concentration P profiles were obtained by secondary ion mass spectrometry. Carrier concentration and mobility profile measurements were carried out by sheet resistance and Hall measurements on implanted van der Pauw patterns. Carrier concentration profiles were also obtained by spreading resistance (SR) measurements. The damage in the as-implanted samples was determined by backscattering and channeling spectrometry (RBS) as a function of the dose and implantation energy. Comparison of random implants in crystal with implants in amorphous layers shows that in the first case it is impossible to completely avoid the channeling tail. In the implants performed under channeling conditions at low doses the P profiles are flat over more than 2 μm thick layers. Furthermore, by increasing the implanted dose, the shape of the profiles dramatically changes due to the dechanneling caused by the crystal disorder. The data are discussed and compared with Monte Carlo simulations using the MARLOWE code. A simple description of the electronic energy loss provides an excellent agreement between the calculated and experimental profiles. (orig.)

  12. REFRACTORY CEPHALEA AND RHINITIS FOLLOWING DENTAL IMPLANT

    Directory of Open Access Journals (Sweden)

    ENRIQUE COSCARÓN-BLANCO

    2018-05-01

    Full Text Available INTRODUCTION: Dental implants are prosthetic devices that are inserted into the thickness of the bone of the maxilla for osseointegration using a screw system. They are increasingly used for both functional and aesthetic reasons. As in any medical or surgical procedure, there are some typical risks and possible sequelae that must be explained and prevented. However, sometimes not-associated-with-implantation rare complications that can cause great morbidity and decrease in the quality of life of the implant recipient can occur. A case of an unusual complication is reported,MATERIAL AND METHODS: A 65-year-old woman presented with a permanent mainly right-sided bilateral nasal obstruction with frequent watery rhinorrhea and headache with retro-orbital and infraorbital irradiation refractory to broad-spectrum antibiotic treatment, corticosteroids and analgesics that she associated with a dental implant two weeks before. . Sinusitis or implant-related complication were ruled out by the dentist and her Primary Care Physician, and therefore she was referred to otorhinolaryngological assessment after radiological study with maxillary sinuses free of disease. The physical examination demostrated inferior obstructive hypertrophic turbinates from the anterior third and thick clear rhinorrhea. After topic tetracaine with adrenaline ,retraction of the turbinates revealed a screw that after breaking the floor of the right nostril entered the thickness of the inferior turbinate. In the left nostril, soil procidence is identified with turbinal contact. An orthopantomography demonstrated the findings described above, highlighting also how the implant was inserted into the skeleton of the inferior turbinate. The sympthoms resolved after removal of the implant. Topical oxymetazoline and corticosteroids provided little relief meanwhile. DISCUSSION AND CONCLUSIONS: The functional objectives sought with dental implants can be compromised by complications such as the

  13. A Strange Case of Downward Displacement of a Deep Brain Stimulation Electrode 10 Years Following Implantation: The Gliding Movement of Snakes Theory.

    Science.gov (United States)

    Iacopino, Domenico Gerardo; Maugeri, Rosario; Giugno, Antonella; Giller, Cole A

    2015-08-01

    Despite the best efforts to ensure stereotactic precision, deep brain stimulation (DBS) electrodes can wander from their intended position after implantation. We report a case of downward electrode migration 10 years following successful implantation in a patient with Parkinson disease. A 53-year-old man with Parkinson disease underwent bilateral implantation of DBS electrodes connected to a subclavicular 2-channel pulse generator. The generator was replaced 7 years later, and a computed tomography (CT) scan confirmed the correct position of both leads. The patient developed a gradual worsening affecting his right side 3 years later, 10 years after the original implantation. A CT scan revealed displacement of the left electrode inferiorly into the pons. The new CT scans and the CT scans obtained immediately after the implantation were merged within a stereotactic planning workstation (Brainlab). Comparing the CT scans, the distal end of the electrode was in the same position, the proximal tip being significantly more inferior. The size and configuration of the coiled portions of the electrode had not changed. At implantation, the length was 27.7 cm; after 10 years, the length was 30.6 cm. These data suggests that the electrode had been stretched into its new position rather than pushed. Clinicians evaluating patients with a delayed worsening should be aware of this rare event. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  15. Microleakage at the Different Implant Abutment Interface: A Systematic Review

    Science.gov (United States)

    Chowdhary, Ramesh; Kumari, Shail

    2017-01-01

    Introduction Presence of gap at the implant-abutment interface, leads to microleakage and accumulation of bacteria which can affect the success of dental implants. Aim To evaluate the sealing capability of different implant connections against microleakage. Materials and Methods In January 2017 an electronic search of literature was performed, in Medline, EBSCO host and Pubmed data base. The search was focused on ability of different implant connections in preventing microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full text reading. Results In this systematic review, literature search initially resulted in 78 articles among which 30 articles only fulfilled the criteria for inclusion and were finally included in the review. Almost all the studies showed that there was some amount of microleakage at abutment implant interface. Microleakage was very less in Morse taper implants in comparison to other implant connections. Majority of studies showed less microleakage in static loading conditions and microleakage increases in dynamic loading conditions. Conclusion In this systematic review maximum studies showed that there was some amount of microleakage at abutment implant interface. External hexagon implants failed completely to prevent microleakage in both static and dynamic loading conditions of implants. Internal hexagon implants mainly internal conical (Morse taper) implants are very promising in case of static loading and also showed less microleakage in dynamic loading conditions. Torque recommended by manufacturer should be followed strictly to get a better seal at abutment implant interface. Zirconia abutments are more to microleakage than Titanium abutments and there use should be discouraged. Zirconia abutments should be only restricted to cases where there was very high demand of aesthetics. PMID:28764310

  16. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  17. Immediate placement and restoration of dental implants in the esthetic region: clinical case series.

    Science.gov (United States)

    Khzam, Nabil; Mattheos, Nikos; Roberts, David; Bruce, William L; Ivanovski, Saso

    2014-01-01

    The objective of this study was to assess the hard and soft tissue changes following immediate placement and provisional restoration of single-tooth implants in the aesthetic zone. Thirteen patients with immediately placed and restored implants were included in this study. All participating patients underwent the same treatment strategy that involved removal of the failed tooth, flapless surgery, immediate implant placement, and connection of a screw-retained provisional restoration. Three months following implant placement, the temporary crowns were replaced by the definitive restorations. Implant survival rates, and hard and soft tissue changes were measured using periapical X-rays and photographs. The range of the observation period was between 12 and 37 months with a mean period of 23.2 ± 7.6 months. At the time of follow-up, all implants were present with no complications. Radiographic evaluation revealed a mean mesial bone gain of 1.20 ± 1.01 mm and a mean distal bone gain of 0.80 ± 1.14 mm, which reached statistical significance. The mean mid-buccal recession was 0.20 ± 0.78 mm, whereas the mesial and distal papillae height loss was 0.50 ± 1.26 mm and 0.30 ± 0.82 mm, respectively. The changes in the soft tissues did not reach statistical significance. Notwithstanding the limitation of a small sample size, this study shows that immediate implant placement and provisional restoration in the maxillary aesthetic zone can result in favorable treatment outcomes with regards to soft and hard tissues changes over a follow-up period of 23.2 ± 7.6 months. Most clinical trials investigating immediate implant placement and immediate restoration in the maxillary anterior zone have focused on implant survival and implant success, with particular emphasis on radiographically assessed hard tissues changes. However, this study assesses the soft tissue changes associated with this procedure, which is an important area of study

  18. Bilateral Intravitreal Dexamethasone Implant for Retinitis Pigmentosa-Related Macular Edema

    Directory of Open Access Journals (Sweden)

    Ali Osman Saatci

    2013-03-01

    Full Text Available Purpose: To report the efficacy of intravitreal dexamethasone implant in a patient with retinitis pigmentosa and bilateral cystoid macular edema unresponsive to topical carbonic anhydrase inhibitors. Case Report: A 36-year-old man with bilateral cystoid macular edema associated with retinitis pigmentosa that was unresponsive to topical carbonic anhydrase inhibitors underwent bilateral 0.7-mg intravitreal dexamethasone implants two weeks apart. Spectral domain optical coherence tomography revealed resolution of macular edema one week following each injection in both eyes and his visual acuity improved. However, macular edema recurred two months later in OS and three months later in OD. Second implant was considered for both eyes. No implant-related complication was experienced during the follow-up of seven months. Conclusion: Inflammatory process seems to play a role in retinitis pigmentosa. Intravitreal dexamethasone implant may offer retina specialists a therapeutic option especially in cases unresponsive to other treatment regimens in eyes with retinitis pigmentosa-related macular edema.

  19. Implante transcateter de valva aórtica: resultados atuais do desenvolvimento e implante de um nova prótese brasileira Transcatheter aortic valve implantation: results of the current development and implantation of a new Brazilian prosthesis

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2011-09-01

    Full Text Available OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, contraindicando o procedimento. O implante minimamente invasivo transcateter de valva aórtica parece ser alternativa, reduzindo a morbimortalidade. A avaliação dos resultados clínicos, segurança e eficácia do procedimento são o objetivo desse estudo. MÉTODOS: Uma prótese transcateter, balão expansível foi utilizada em 33 casos de alto risco. EuroScore médio foi de 39,30% e STS score de 30,28%. Oito pacientes apresentavam disfunção de bioprótese e o restante, estenose aórtica calcificada. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Através de minitoracotomia esquerda, as próteses foram implantadas pelo ápice ventricular, sob estimulação de alta frequência ou choque hemorrágico. Foram realizados controles clínicos e ecocardiográficos. RESULTADOS: A correta liberação da prótese foi possível em 30 casos. Três conversões ocorreram. A mortalidade operatória foi de um caso e a mortalidade em 30 dias, 18,18%. O gradiente médio reduziu de 43,58 para 10,54 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual esteve presente em 30,30% dos pacientes. Ocorreu uma complicação vascular periférica e um caso de bloqueio atrioventricular total. Um paciente apresentou acidente vascular cerebral. A mortalidade em 30 dias foi de 18,18%. CONCLUSÃO: O implante transapical de valva aórtica transcateter é procedimento seguro e com resultados de médio prazo satisfatórios. São necessários estudos de longo prazo com maior poder amostral no intuito de determinar resultado hemodinâmico, qualidade de vida e sobrevida em longo prazoOBJECTIVE: Aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such risk can justify contraindication

  20. Audiological outcomes of cochlear implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Magalhães, Ana Tereza de Matos

    2014-01-01

    Full Text Available Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2% were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  1. Audiological outcomes of cochlear implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-07-01

     The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss.  To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations.  This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed.  During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor.  Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  2. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  3. Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.

    Science.gov (United States)

    Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J

    2012-08-01

    Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.

  4. Accidental injections of dexamethasone intravitreal implant (Ozurdex) into the crystalline lens.

    Science.gov (United States)

    Coca-Robinot, Javier; Casco-Silva, Bruno; Armadá-Maresca, Felix; García-Martínez, Jesús

    2014-01-01

    To describe the side effects and management after inadvertent injection of a dexamethasone implant (Ozurdex) into the crystalline lens. Two case reports. Two patients with macular edema due to unilateral retinal vein occlusion were scheduled for an intravitreal injection of Ozurdex. During the procedure, the implant was accidentally injected into the crystalline lens. Both patients developed cataracts during the course of several weeks and in both there was an intraocular pressure (IOP) increase, which required treatment with topical hypotensives. Macular edema improved only slightly. Cataract surgery with uneventful removal of the implant was performed 3 (case 1) and 6 months (case 2) after the injection. After inadvertent injection of Ozurdex into the crystalline lens, cataract surgery with removal of the implant should be performed as soon as possible in order to avoid IOP increase and so that the underlying condition may be treated adequately.

  5. Extraction of retinal tacks from subjects implanted with an epiretinal visual prosthesis.

    Science.gov (United States)

    de Juan, Eugene; Spencer, Rand; Barale, Pierre-Olivier; da Cruz, Lyndon; Neysmith, Jordan

    2013-10-01

    Retinal tacks, first developed for the treatment of complex retinal detachments, have more recently been used for the fixation of epiretinal electrode arrays as part of implanted visual prostheses. Here, we report on the clinical experience of extracting four such tacks after chronic implantation. The ability to safely extract retinal tacks ensures that epiretinal devices can be repositioned or removed if necessary. Custom-built, titanium alloy retinal tacks were mechanically removed from the posterior coats after prolonged implantation (up to 19 months). The resulting wound was characterized by clinical evaluation, fundus photography, and fluorescein angiography while being monitored for stability over time. The wounds were also compared to earlier published reports of the healing response around retinal tacks in human subjects. Tack extraction was accomplished successfully, without complication, in all four subjects. The wound site was readily identified by pale scar tissue. No change in the wound size or appearance was noted over many months of post-operative observation (up to 22 months after explant). No adverse effects on overall ocular health were detected. Extraction of retinal tacks from subjects implanted with epiretinal prostheses can be performed without significant complication. The long-term healing response appears to be stable and localized in eyes afflicted with retinitis pigmentosa or choroideremia. There was also minimal, if any, impact on the local circulatory system. These cases suggest that the use of retinal tacks for anchoring epiretinal visual prostheses does not preclude safe repositioning or removal of the device more than a year after implant.

  6. Interaction of nitrogen with vacancy defects in N+-implanted ZnO studied using a slow positron beam

    International Nuclear Information System (INIS)

    Chen, Z.Q.; Maekawa, M.; Kawasuso, A.; Suzuki, R.; Ohdaira, T.

    2005-01-01

    ZnO crystals were implanted with N + , O + , and Al + , and co-implanted with O + /N + and Al + /N + ions. Positron annihilation measurements indicate introduction of vacancy clusters upon implantation. In the N + -implanted and Al + /N + co-implanted samples, these vacancy clusters are only partially annealed at 800 deg. C, as compared with their entire recovery in the O + - and Al + -implanted samples at 800-900 deg. C, suggesting a strong interaction between nitrogen and vacancy clusters. However, in the O + /N + co-implanted sample, most vacancy clusters disappear at 800 deg. C. Probably oxygen scavenges nitrogen to enhance the annealing of the vacancy clusters. Upon further annealing at 1000-1100 deg. C, nitrogen also forms stable complexes with thermally generated vacancies. These nitrogen-related vacancy complexes need high-temperature annealing at 1200-1250 deg. C to be fully removed

  7. [Patient-related complexity in nursing care - Collective case studies in the acute care hospital].

    Science.gov (United States)

    Gurtner, Caroline; Spirig, Rebecca; Staudacher, Diana; Huber, Evelyn

    2018-06-04

    Patient-related complexity in nursing care - Collective case studies in the acute care hospital Abstract. Patient-related complexity of nursing is defined by the three characteristics "instability", "uncertainty", and "variability". Complexity increased in the past years, due to reduced hospital length of stay and a growing number of patients with chronic and multiple diseases. We investigated the phenomenon of patient-related complexity from the point of view of nurses and clinical nurse specialists in an acute care hospital. In the context of a collective case study design, nurses and clinical nurse specialists assessed the complexity of nursing situations with a questionnaire. Subsequently, we interviewed nurses and clinical nurse specialists about their evaluation of patient-related complexity. In a within-case-analysis we summarized data inductively to create case narratives. By means of a cross-case-analysis we compared the cases with regard to deductively derived characteristics. The four cases exemplarily showed that the degree of complexity depends on the controllability and predictability of clinical problems. Additionally, complexity increases or decreases, according to patients' individual resources. Complex patient situations demand professional expertise, experience, communicative competencies and the ability for reflection. Beginner nurses would benefit from support and advice by experienced nurses to develop these skills.

  8. Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.

    Science.gov (United States)

    Alsanosi, A A

    2015-09-01

    To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.

  9. Biomechanical rationale and evaluation of an implant system for rib fracture fixation

    OpenAIRE

    Bottlang, M.; Walleser, S.; Noll, M.; Honold, S.; Madey, S. M.; Fitzpatrick, D.; Long, W. B.

    2010-01-01

    Background Biomechanical research directed at developing customized implant solutions for rib fracture fixation is essential to reduce the complexity and to increase the reliability of rib osteosynthesis. Without a simple and reliable implant solution, surgical stabilization of rib fractures will remain underutilized despite proven benefits for select indications. This article summarizes the research, development, and testing of a specialized and comprehensive implant solution for rib fractur...

  10. Case Mix Complexity Differences between Teaching and Nonteaching Hospitals.

    Science.gov (United States)

    Ament, Richard P.; And Others

    1981-01-01

    The differences between teaching and nonteaching hospitals in complexity and variety of cases seen are described. The results show that teaching hospitals could be expected to cost somewhat more per patient even if case mix were the only factor. (Author/MLW)

  11. Accuracy of computer-guided implantation in a human cadaver model.

    Science.gov (United States)

    Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi

    2015-10-01

    To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  12. Zirconia implants and peek restorations for the replacement of upper molars

    Directory of Open Access Journals (Sweden)

    José María Parmigiani-Izquierdo

    2017-02-01

    Full Text Available Abstract Background One of the disadvantages of the zirconia implants is the lack of elasticity, which is increased with the use of ceramic or zirconia crowns. The consequences that could result from this lack of elasticity have led to the search for new materials with improved mechanical properties. Case presentation A patient who is a 45-year-old woman, non-smoker and has no medical record of interest with a longitudinal fracture in the palatal root of molar tooth 1.7 and absence of tooth 1.6 was selected in order to receive a zirconia implant with a PEEK-based restoration and a composite coating. The following case report describes and analyses treatment with zirconia implants in molars following a flapless surgical technique. Zirconia implants are an alternative to titanium implants in patients with allergies or who are sensitive to metal alloys. However, one of the disadvantages that they have is their lack of elasticity, which increases with the use of ceramic or zirconia crowns. The consequences that can arise from this lack of elasticity have led to the search for new materials with better mechanical properties to cushion occlusal loads. PEEK-based restoration in implant prosthetics can compensate these occlusal forces, facilitating cushioning while chewing. Conclusion This procedure provides excellent elasticity and resembles natural tooth structure. This clinical case suggests that PEEK restorations can be used in zirconia implants in dentistry.

  13. Improving the Effectiveness of Professional Education: Learning Managerial Accounting via a Complex Case.

    Science.gov (United States)

    Carter, Melissa; And Others

    To give students more experience with real situations, many professional schools use case studies in their courses. Creating complex cases, case experiences that immerse students in complex problems, rather than mere case studies that require armchair analysis should help students gain better and more integrated knowledge. Designing, implementing,…

  14. Surface modification of coronary artery stent by Ti-O/Ti-N complex film coating prepared with plasma immersion ion implantation and deposition

    International Nuclear Information System (INIS)

    Huang, N.; Leng, Y.X.; Yang, P.

    2006-01-01

    This paper reported the work of surface coating of Ti-O/Ti-N complex films on coronary stents by means of the plasma immersion ion implantation/deposition process. The deformation behavior of the Ti-O/Ti-N coated stainless steel stents was investigated. In vivo investigation of the anticoagulation behavior of Ti-O coated coronary stents was also performed. The results of mechanical characterization of the Ti-O/Ti-N coated stents show that the film has strong binding strength, and to some extent the ability to withstand plastic deformation. The biological response behavior of the coated stent surface was significantly different from the uncoated. The results of implantation of stents into rabbit ventral aorta show no thrombus formation on the surfaces of the Ti-O coated stents, although serious coagulation had occurred on the surfaces of unmodified stents over a period of 4 weeks under conditions with no anticoagulant

  15. Impact of Different Surgeons on Dental Implant Failure.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  16. A case of WAGR syndrome in association with developmental glaucoma requiring bilateral Baerveldt glaucoma implants and subsequent tube repositioning

    Directory of Open Access Journals (Sweden)

    Akagi T

    2015-06-01

    Full Text Available Tadamichi Akagi, Munemitsu Yoshikawa, Hideo Nakanishi, Nagahisa Yoshimura Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan Abstract: Glaucoma drainage device implantation is efficacious for the treatment of pediatric glaucoma patients when multiple angle surgeries fail. However, tube touching of the corneal endothelium is one of the major postoperative complications to deal with. A 15-month-old male patient with Wilms’ tumor, aniridia, genitourinary anomalies, and mental retardation (WAGR syndrome was diagnosed with bilateral developmental glaucoma. He underwent Baerveldt glaucoma implant (BGI surgeries in both eyes after multiple failed trabeculotomies. The tube in his right eye was touching the cornea 15 months after BGI surgery. To avoid corneal endothelium damage, BGI tube repositioning with scleral fixation was performed without serious complications. The bilateral BGI surgeries achieved successful intraocular pressure reduction for over 2 years and tube repositioning with scleral fixation of BGI tube was successful for BGI tube malposition. Although careful attention to intraocular pressure and tube malposition is essential after glaucoma drainage device implantation, especially in pediatric cases, BGI surgery is effective in the management of developmental glaucoma following unsuccessful angle surgeries. Keywords: Baerveldt glaucoma implant, developmental glaucoma, WAGR syndrome, tube repositioning, glaucoma drainage device

  17. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  18. A microcontroller-based implantable nerve stimulator used for rats.

    Science.gov (United States)

    Sha, Hong; Zheng, Zheng; Wang, Yan; Ren, Chaoshi

    2005-01-01

    A microcontroller-based stimulator that can be flexible programmed after it has been implanted into a rat was studied. Programmability enables implanted stimulators to generate customized, complex protocols for experiments. After implantation, a coded light pulse train that contains information of specific identification will unlock a certain stimulator. If a command that changing the parameters is received, the microcontroller will update its flash memory after it affirms the commands. The whole size of it is only 1.6 cubic centimeters, and it can work for a month. The devices have been successfully used in animal behavior experiments, especially on rats.

  19. First branchial complex anomalies: report of 3 cases

    International Nuclear Information System (INIS)

    Goten, A. van der; Hermans, R.; Hover, P. van; Crevits, I.; Baert, A.L.

    1997-01-01

    Three cases of first branchial cleft anomalies are presented. The embryology and pathology of first branchial complex anomalies, their imaging characteristics and differential diagnosis are discussed. (orig.). With 3 figs

  20. First branchial complex anomalies: report of 3 cases

    Energy Technology Data Exchange (ETDEWEB)

    Goten, A. van der [Department of Radiology, University Hospitals, Catholic University of Leuven, Leuven (Belgium); Hermans, R. [Department of Radiology, University Hospitals, Catholic University of Leuven, Leuven (Belgium); Hover, P. van [Department of Radiology, University Hospitals, Catholic University of Leuven, Leuven (Belgium); Crevits, I. [Department of Radiology, University Hospitals, Catholic University of Leuven, Leuven (Belgium); Baert, A.L. [Department of Radiology, University Hospitals, Catholic University of Leuven, Leuven (Belgium)

    1997-02-01

    Three cases of first branchial cleft anomalies are presented. The embryology and pathology of first branchial complex anomalies, their imaging characteristics and differential diagnosis are discussed. (orig.). With 3 figs.

  1. Implant-buccal plate distance as diagnostic parameter: a prospective cohort study on implant placement in fresh extraction sockets.

    Science.gov (United States)

    Capelli, Matteo; Testori, Tiziano; Galli, Fabio; Zuffetti, Francesco; Motroni, Alessandro; Weinstein, Roberto; Del Fabbro, Massimo

    2013-12-01

    The aim of this study is to investigate contour changes around immediate implants in fresh extraction sockets when different grafting procedures are performed, based on the distance between the external implant collar and the bony surface on the buccal plate (I-BP). A secondary aim is to assess the esthetic outcome via the implant esthetic score (IAS). This prospective cohort study was performed in three centers. Suitable patients to undergo implant placement in fresh extraction sockets were selected. Periodontal biotype, horizontal and vertical peri-implant bone defects, and dehiscences were assessed. Depending on I-BP, two types of grafting procedures were performed. In group A (I-BP sockets. No implant failed during the observation period. The mean follow-up was 25 months (range: 12 to 37 months). After 1 year of loading, group A showed a slight decrease in mean buccal volume, whereas group B had an increase in volume (P = 0.02). IAS was higher for group B than group A. When implants are placed immediately after tooth extraction, I-BP may represent a useful diagnostic parameter in choosing the most appropriate grafting procedure (IG versus IEG). In clinical cases in which the distance between implant surface and the buccal plate is <4 mm, the combination of internal and external grafting (IEG) is recommended to maintain the volume and the contour of the ridge and achieve a successful esthetic outcome.

  2. Implantable Medical Devices; Networking Security Survey

    OpenAIRE

    Siamak Aram; Rouzbeh A. Shirvani; Eros G. Pasero; Mohamd F. Chouikha

    2016-01-01

    The industry of implantable medical devices (IMDs) is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable dev...

  3. Wireless power transfer and data communication for neural implants case study : epilepsy monitoring

    CERN Document Server

    Yilmaz, Gürkan

    2017-01-01

    This book presents new circuits and systems for implantable biomedical applications targeting neural recording. The authors describe a system design adapted to conform to the requirements of an epilepsy monitoring system. Throughout the book, these requirements are reflected in terms of implant size, power consumption, and data rate. In addition to theoretical background which explains the relevant technical challenges, the authors provide practical, step-by-step solutions to these problems. Readers will gain understanding of the numerical values in such a system, enabling projections for feasibility of new projects. Provides complete, system-level perspective for implantable batteryless biomedical system; Extends design example to implementation and long term in-vitro validation; Discusses system design concerns regarding wireless power transmission and wireless data communication, particularly for systems in which both are performed on the same channel/frequency; Presents fully-integrated, implantable syste...

  4. Ultrasonographic diagnosis of limb-body wall complex: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Dong Erk; Yoo, Shi Joon; Cho, Kyoung Sik; Choi, Kee Young; Kim, Am [University of Ulsan College of Medicine, Asan Medical Center, Ulsan (Korea, Republic of)

    1993-12-15

    Limb-body wall complex (LBWC) is a rare congenital process believed to result from early rupture of the amnion, possibly as a consequence of vascular disruption. Characteristic fetal deformities include limb defects, scoliosis, thoracoschisis and/or abdominoschisis, and severe craniofacial anomalies. This complex should be distinguished from other body-wall defect including omphalocele and gastroschisis since the prognosis of LBWC is uniformly poor. We report a case of LBWC which was diagnosed by prenatal ultrasonography in 26 weeks of gestation. Prenatal ultrasonograms are correlated with the gross pathologic findings. The present case demonstrates the superb capability of modern ultrasonography in the diagnosis of complex fetal anomalies

  5. Ultrasonographic diagnosis of limb-body wall complex: a case report

    International Nuclear Information System (INIS)

    Goo, Dong Erk; Yoo, Shi Joon; Cho, Kyoung Sik; Choi, Kee Young; Kim, Am

    1993-01-01

    Limb-body wall complex (LBWC) is a rare congenital process believed to result from early rupture of the amnion, possibly as a consequence of vascular disruption. Characteristic fetal deformities include limb defects, scoliosis, thoracoschisis and/or abdominoschisis, and severe craniofacial anomalies. This complex should be distinguished from other body-wall defect including omphalocele and gastroschisis since the prognosis of LBWC is uniformly poor. We report a case of LBWC which was diagnosed by prenatal ultrasonography in 26 weeks of gestation. Prenatal ultrasonograms are correlated with the gross pathologic findings. The present case demonstrates the superb capability of modern ultrasonography in the diagnosis of complex fetal anomalies

  6. Hydroxyapatite-coated magnesium implants with improved in vitro and in vivo biocorrosion, biocompatibility, and bone response.

    Science.gov (United States)

    Kim, Sae-Mi; Jo, Ji-Hoon; Lee, Sung-Mi; Kang, Min-Ho; Kim, Hyoun-Ee; Estrin, Yuri; Lee, Jong-Ho; Lee, Jung-Woo; Koh, Young-Hag

    2014-02-01

    Magnesium and its alloys are candidate materials for biodegradable implants; however, excessively rapid corrosion behavior restricts their practical uses in biological systems. For such applications, surface modification is essential, and the use of anticorrosion coatings is considered as a promising avenue. In this study, we coated Mg with hydroxyapatite (HA) in an aqueous solution containing calcium and phosphate sources to improve its in vitro and in vivo biocorrosion resistance, biocompatibility and bone response. A layer of needle-shaped HA crystals was created uniformly on the Mg substrate even when the Mg sample had a complex shape of a screw. In addition, a dense HA-stratum between this layer and the Mg substrate was formed. This HA-coating layer remarkably reduced the corrosion rate of the Mg tested in a simulated body fluid. Moreover, the biological response, including cell attachment, proliferation and differentiation, of the HA-coated samples was enhanced considerably compared to samples without a coating layer. The preliminary in vivo experiments also showed that the biocorrosion of the Mg implant was significantly retarded by HA coating, which resulted in good mechanical stability. In addition, in the case of the HA-coated implants, biodegradation was mitigated, particularly over the first 6 weeks of implantation. This considerably promoted bone growth at the interface between the implant and bone. These results confirmed that HA-coated Mg is a promising material for biomedical implant applications. © 2013 Wiley Periodicals, Inc.

  7. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

    Science.gov (United States)

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-06-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case.

  8. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  9. Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

    Science.gov (United States)

    Mishra, Sunil Kumar; Chowdhary, Ramesh

    2014-06-01

    Osseointegration is the more stable situation and results in a high success rate of dental implants. Heat generation during rotary cutting is one of the important factors influencing the development of osseointegration. To assess the various factors related to implant drills responsible for heat generation during osteotomy. To identify suitable literature, an electronic search was performed using Medline and Pubmed database. Articles published in between 1960 to February 2013 were searched. The search is focused on heat generated by dental implant drills during osteotomy. Various factors related to implant drill such effect of number of blades; drill design, drill fatigue, drill speed and force applied during osteotomies which were responsible for heat generation were reviewed. Titles and abstracts were screened, and literature that fulfilled the inclusion criteria was selected for a full-text reading. The initial literature search resulted in 299 articles out of which only 70 articles fulfils the inclusion criteria and were included in this systematic review. Many factors related to implant drill responsible for heat generation were found. Successful preparation of an implant cavity with minimal damage to the surrounding bone depends on the avoidance of excessive temperature generation during surgical drilling. The relationship between heat generated and implant drilling osteotomy is multifactorial in nature and its complexity has not been fully studied. Lack of scientific knowledge regarding this issue still exists. Further studies should be conducted to determine the various factors which generate less heat while osteotomy such as ideal ratio of force and speed in vivo, exact time to replace a drill, ideal drill design, irrigation system, drill-bone contact area.

  10. Anaplastic large cell lymphoma associated with breast implants

    Directory of Open Access Journals (Sweden)

    Vid Bajuk

    2017-02-01

    Full Text Available An increasing number of women worldwide decide for esthetic correction of breasts with silicone implants and post-cancer breast reconstruction with tissue expanders and silicone breast implants. It is estimated that more than 10 million women around the globe have them. Tere are approximately 200 known cases of patients with anaplastic large cell lymphoma (ALCL linked with silicone breast implants reported in medical literature. ALCL is a rare disease with an annual incidence of 0.1–0.3/100 000 women with breast silicone implants. In the presence of clinical signs, physician should also consider this rare form of ALCL in differential diagnosis. Patients are on average 50 years old. Long afer implantation surgery, the patient may experience breast swelling, pain and/or asymmetry. In diagnostics, ultrasound and cytological examination are required. During ultrasound examination fluid formation (seroma or solid tumor mass can be detected. Treatment is individualized. Due to tumor nature, implant resection and total capsulectomy are usually indicated; also, chemo- and radiotherapy might rarely be required. Five-year survival rate depends on tumor form and correlates well with clinical fndings of seroma or solid mass. In the more frequent form, seroma, fve-year survival rate is 100 %, while in the case of solid tumor mass fve-year survival rate is 75 %. The rarity of this disease makes it difficult to diagnose, but nevertheless, early detection and treatment are important for better recovery.

  11. Maxillary overdentures supported by anteriorly or posteriorly placed implants opposed by a natural dentition in the mandible: a 1-year prospective case series study.

    Science.gov (United States)

    Slot, Wim; Raghoebar, Gerry M; Vissink, Arjan; Meijer, Henny J A

    2014-02-01

    For maxillary overdenture therapy, treatment guidelines are missing. There is a need for longitudinal studies. The purpose of this 1-year prospective case series study was to assess the treatment outcome of maxillary overdentures supported by six dental implants opposed by natural antagonistic teeth in the mandible. Fifty patients were treated with a maxillary overdenture supported by six dental implants, either placed in the anterior region (n = 25 patients) or in the posterior region (n = 25 patients). Items of evaluation were the following: survival of implants, condition of hard and soft peri-implant tissues, and patients' satisfaction. One-year implant survival rate was 98% in the anterior group and 99.3% in the posterior group. Mean radiographic bone loss in the anterior and posterior groups after 1 year of loading was 0.22 and 0.50 mm, respectively. Mean scores for plaque, calculus, gingiva, bleeding, and pocket probing depth were low, and patients' satisfaction was high, with no differences between the groups. Six dental implants placed in either the anterior region or the posterior region of the edentulous maxilla, connected with a bar, and opposed by antagonistic teeth in the mandible supply a proper base for the support of an overdenture. © 2012 Wiley Periodicals, Inc.

  12. Persistent Hypotony Associated with Immunosuppressive Therapy in Glaucoma Drainage Implant Surgery

    Directory of Open Access Journals (Sweden)

    Susana Duch

    2016-09-01

    Full Text Available Purpose: To describe the histopathology of non-valved implant capsules in three cases of persistent postoperative hypotony after the restrictive tube ligature was released in patients receiving immunosuppressive therapy. Observations: The macroscopic appearance of the capsules 3 and 4 months postoperatively was immature and loose. Microscopic examination disclosed extremely irregular thin tissue, with thicknesses ranging from 0.02 to 0.6 mm, depending on the capsular location studied. Withdrawal of immunosuppressive therapy did not facilitate rebuilding of new capsules. Replacement with a valved implant device was necessary in two cases; the third case recovered with tapering of prednisone. Conclusions and Importance: The use of chronic systemic immunosuppressive therapy might interfere with capsular formation around the plates of drainage devices inducing persistent hypotony. In these cases, the use of valved implants might be safer.

  13. Percutaneous implantation of intra-arterial port system for regional drug infusion: results and complications in 110 cases

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Hyuk; Ko, Kyung Hee; Won, Jong Yoon; Park, Sung Il; Lee, Do Yun; Kang, Byung Chul

    2000-01-01

    To investigate the feasibility and complications of a percutaneously implantable port system for regional drug infusion. For intra-arterial drug infusion, a 5.8 or 5-F pediatric venous port system was implanted in 110 patients with hepatocellular carcinoma (n=79), liver metastasis (n=16), gallbladder cancer (n=4), stomach cancer (n=3), pancreatic cancer (n=3), Burger's diseases mellitus (n=2), or lymphoma (n=1). All intra-arterial port implantations were performed percutaneously in an angiographic ward through the common femoral artery (n=98), left subclavian artery (n=10), or left superficial femoral artery (n=2). Complications were evaluated during the follow-up period, which ranged from 21 to 530 (mean, 163) days. The technical success rate for percutaneous implantation of the system was 97.3% (107 of 110 patients). The tips of the port catheter were located in the common hepatic artery (n=34), proper hepatic artery (n=49), right hepatic artery quick resulthepatic artery (n=1), descending aorta at T9 level (n=10), left popliteal artery (n=2), right external iliac artery (n=1), left external iliac artery (n=1), or left deep femoral artery (n=1). Complications were encountered in 24 patients (22.4%), namely chamber site infection (n=7), catheter dislodgement (n=7), catheter occlusion (n=3), migration of coil (n=2), disconnection between chamber and catheter (n=1), kinking of catheter (n=1), arterial occlusion (n=1), necrosis of overlying skin (n=1), and leakage around port chamber (n=1). Outcomes of complications included removal of port systems or cessation of therapy in 12 cases (11.2%), correction of catheter location using a guide wire in five (4.7%), thrombolysis with urokinase in three (2.8%), and straightening using a snare in one (0.9%). In three patients, the port system was used without reintervention. Percutaneous implantation of an intra-arterial port system showed a high technical success rate and a low rate of serious complications. The method may be

  14. Image-guided navigation system for placing dental implants.

    Science.gov (United States)

    Casap, Nardy; Wexler, Alon; Lustmann, Joshua

    2004-10-01

    Navigation-guided surgery has recently been introduced into various surgical disciplines, including oral and maxillofacial surgery. Since the advent of dental implants, dental computed tomography (CT) scans have been used as a diagnostic tool for preoperative planning, but not as part of the surgical phase. This article explains the principles of computer-assisted surgery and describes the use of a computer-guided navigation system in dental implantology. The system uses preoperative dental CT scans for planning and as an integral part of the surgical procedure. This system allows continuous intraoperative coordination of the implantation phase with the preoperative plan, optimizing the accuracy of implant surgery. Deviations from the planned location of the implants are minimal. Several cases are discussed.

  15. Diode laser and periodontal regeneration-assisted management of implant complications in anterior maxilla

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Salaria

    2018-01-01

    Full Text Available Dental implant is being considered successful if the patient is pleased with both of its functional and esthetic outcome. As implant complications (such as peri-implantitis, inappropriate implant position, wrong angulation, and implant location too close to anatomical structures have been frequently encountered in dental practice, therefore, thorough knowledge to manage such complications is the key prerequisite to prevent the failure of implant. The present case report discussed the etiology, diagnosis of early peri-implantitis, and periodontal abscess with their successful management through periodontal regeneration and diode laser-assisted therapy.

  16. Diode Laser and Periodontal Regeneration-Assisted Management of Implant Complications in Anterior Maxilla.

    Science.gov (United States)

    Salaria, Sanjeev Kumar; Sharma, Isha; Brar, Navjot Kaur; Kaur, Satwant

    2018-01-01

    Dental implant is being considered successful if the patient is pleased with both of its functional and esthetic outcome. As implant complications (such as peri-implantitis, inappropriate implant position, wrong angulation, and implant location too close to anatomical structures) have been frequently encountered in dental practice, therefore, thorough knowledge to manage such complications is the key prerequisite to prevent the failure of implant. The present case report discussed the etiology, diagnosis of early peri-implantitis, and periodontal abscess with their successful management through periodontal regeneration and diode laser-assisted therapy.

  17. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  18. Case report: acquisition of three spoken languages by a child with a cochlear implant.

    Science.gov (United States)

    Francis, Alexander L; Ho, Diana Wai Lam

    2003-03-01

    There have been only two reports of multilingual cochlear implant users to date, and both of these were postlingually deafened adults. Here we report the case of a 6-year-old early-deafened child who is acquiring Cantonese, English and Mandarin in Hong Kong. He and two age-matched peers with similar educational backgrounds were tested using common, standardized tests of vocabulary and expressive and receptive language skills (Peabody Picture Vocabulary Test (Revised) and Reynell Developmental Language Scales version II). Results show that this child is acquiring Cantonese, English and Mandarin to a degree comparable to two classmates with normal hearing and similar educational and social backgrounds.

  19. Successful bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

    Science.gov (United States)

    Coutinho, M B; Marques, C; Mendes, G J; Gonçalves, C

    2015-11-01

    To report a case of successful bone-anchored hearing aid implantation in an adult patient with type III osteogenesis imperfecta, which is commonly regarded as a contraindication to this procedure. A 45-year-old man with type III osteogenesis imperfecta presented with mixed hearing loss. There was a mild sensorineural component in both ears, with an air-bone gap between 45 and 50 dB HL. He was implanted with a bone-anchored hearing aid. The audiological outcome was good, with no complications and good implant stability (as measured by resonance frequency analysis). To our knowledge, this is the first recorded case of bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

  20. ERP IMPLANTATION: KEY FACTORS OF SUCCESS AND IMPACT ON PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Dumitru Valentin

    2008-05-01

    Full Text Available The implantation of an ERP (abbreviation for "Enterprise Resource Planning" system is an enterprise project that implies the remodeling of the information system, mostly the rethinking of management procedures within the organization. The expansion and the complexity of these projects demand a theoretical framework and « optimal practices » in order to model and to evaluate the key factors of implementation success and to analyze its impact on the organization’s performance. The research problem of our communication can be divided into three research questions: - What conceptual framework for ERP implantation? - What are the key factors of success in ERP implantation? - What is the relationship between ERP implantation and enterprise performance?

  1. Fixation free femoral hernia repair with a 3D dynamic responsive implant. A case series report.

    Science.gov (United States)

    Amato, G; Romano, G; Agrusa, A; Gordini, L; Gulotta, E; Erdas, E; Calò, P G

    2018-04-23

    To date, no gold standard for the surgical treatment of femoral hernia exists. Pure tissue repair as well as mesh/plug implantation, open or laparoscopic, are the most performed methods. Nevertheless, all these techniques need sutures or mesh fixation. This implies the risk of damaging sensitive structures of the femoral area, along with complications related to tissue tear and postoperative discomfort consequent to poor quality mesh incorporation. The present retrospective multicenter case series highlights the results of femoral hernia repair procedures performed with a 3D dynamic responsive implant in a cohort of 32 patients during a mean follow up of 27 months. Aiming to simplify the surgical procedure and reduce complications, a 3D dynamic responsive implant was delivered for femoral hernia repair, in a patient cohort. After returning the hernia sack to the abdominal cavity, the implant was simply delivered into the hernia defect where it remained, thanks to its inherent centrifugal expansion, obliterating the hernia opening without need of fixation. Postoperative pain assessment was determined using the VAS score system. The use of the 3D prosthetic device allowed for easier and faster surgical repair in a fixation free fashion. None of the typical fixation related complications occurred in the examined patients. Postoperative pain assessment with VAS score showed a very low level of pain, allowing the return of patients to normal activities in extremely reduced times. In the late postoperative period, no discomfort or chronic pain was reported. Femoral hernia repair with the 3D dynamic revealed a quick and safe placement procedure. The reduced pain intensity, as well as the absence of adverse events consequent to sutures or mesh fixation, seems to be a significant benefit of the motile compliance of the device. Furthermore, this 3D prosthesis has already proven to induce an enhanced probiotic response showing ingrowth in the implant of the typical tissue

  2. Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method.

    Science.gov (United States)

    Bulaqi, Haddad Arabi; Mousavi Mashhadi, Mahmoud; Geramipanah, Farideh; Safari, Hamed; Paknejad, Mojgan

    2015-05-01

    To prevent screw loosening, a clear understanding of the factors influencing secure preload is necessary. The purpose of this study was to investigate the effect of coefficient of friction and tightening speed on screw tightening based on energy distribution method with exact geometric modeling and finite element analysis. To simulate the proper boundary conditions of the screw tightening process, the supporting bone of an implant was considered. The exact geometry of the implant complex, including the Straumann dental implant, direct crown attachment, and abutment screw were modeled with Solidworks software. Abutment screw/implant and implant/bone interfaces were designed as spiral thread helixes. The screw-tightening process was simulated with Abaqus software, and to achieve the target torque, an angular displacement was applied to the abutment screw head at different coefficients of friction and tightening speeds. The values of torque, preload, energy distribution, elastic energy, and efficiency were obtained at the target torque of 35 Ncm. Additionally, the torque distribution ratio and preload simulated values were compared to theoretically predicted values. Upon reducing the coefficient of friction and enhancing the tightening speed, the angle of turn increased at the target torque. As the angle of turn increased, the elastic energy and preload also increased. Additionally, by increasing the coefficient of friction, the frictional dissipation energy increased but the efficiency decreased, whereas the increase in tightening speed insignificantly affected efficiency. The results of this study indicate that the coefficient of friction is the most influential factor on efficiency. Increasing the tightening speed lowered the response rate to the frictional resistance, thus diminishing the coefficient of friction and slightly increasing the preload. Increasing the tightening speed has the same result as reducing the coefficient of friction. Copyright © 2015

  3. N and Cr ion implantation of natural ruby surfaces and their characterization

    Energy Technology Data Exchange (ETDEWEB)

    Rao, K. Sudheendra; Sahoo, Rakesh K.; Dash, Tapan [CSIR-Institute of Minerals and Materials Technology, Bhubaneswar 751013 (India); Magudapathy, P.; Panigrahi, B.K. [Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India); Nayak, B.B.; Mishra, B.K. [CSIR-Institute of Minerals and Materials Technology, Bhubaneswar 751013 (India)

    2016-04-15

    Highlights: • Cr and N ion implantation on natural rubies of low aesthetic quality. • Cr-ion implantation improves colour tone from red to deep red (pigeon eye red). • N-ion implantation at fluence of 3 × 10{sup 17} causes blue coloration on surface. • Certain extent of amorphization is observed in the case of N-ion implantation. - Abstract: Energetic ions of N and Cr were used to implant the surfaces of natural rubies (low aesthetic quality). Surface colours of the specimens were found to change after ion implantation. The samples without and with ion implantation were characterized by diffuse reflectance spectra in ultra violet and visible region (DRS-UV–Vis), field emission scanning electron microscopy (FESEM), selected area electron diffraction (SAED) and nano-indentation. While the Cr-ion implantation produced deep red surface colour (pigeon eye red) in polished raw sample (without heat treatment), the N-ion implantation produced a mixed tone of dark blue, greenish blue and violet surface colour in the heat treated sample. In the case of heat treated sample at 3 × 10{sup 17} N-ions/cm{sup 2} fluence, formation of colour centres (F{sup +}, F{sub 2}, F{sub 2}{sup +} and F{sub 2}{sup 2+}) by ion implantation process is attributed to explain the development of the modified surface colours. Certain degree of surface amorphization was observed to be associated with the above N-ion implantation.

  4. Immediate loading with single-piece implant following extraction

    Directory of Open Access Journals (Sweden)

    Hemlata Dwivedi

    2017-01-01

    Full Text Available Although dental implantology had evolved over a number of years, many dental surgeons are unaware of the concept of immediate loading with the use of one-piece implant that began in the early 1960s. The goal of successful prosthodontics rehabilitation is to provide function, esthetics, and comfort to the patient. The aim of this literature is to provide an overview of one-piece implant, with its advantages and disadvantages over conventional two-piece implant. Immediate prosthetic of a one-piece system allows for a better tissue healing and better adhesion of gingival mucosa to form a collar which is healthy and adherent to the implant, avoiding a second surgical procedure, and also includes a very important aspect esthetics. This article describes a case report of immediate loading with single-piece implant following extraction.

  5. Pain-only complaint about cochlear implant device: A five-patient pediatric experience.

    Science.gov (United States)

    Todd, Norman Wendell; Fainberg, Jolie C; Ukatu, CeIsha Chinwe; Venable, Claudia Y; Segel, Phil

    2015-09-01

    To present the case histories and management of five pediatric patients who experienced pain at the receiver-stimulator site, but no other indication that the device was failing. Patients were from a sole-surgeon pediatric practice (600 + implant surgeries before June 2013; about even proportions of Advanced Bionics, Cochlear Corporation, and MED-EL devices). The University Institutional Review Board-approved review of sole-surgeon pediatric case series. The onset of pain ranged from 2 to 16 years post implantation. Pain, not amenable to conventional medical therapy, was present regardless of whether or not the external appliance was 'on', or even being worn on the head. Four of the five patients were bilaterally implanted, but pain was only at one receiver-stimulator package. Clinical management ultimately included revision surgery in all five cases, with immediate resolution of the pain in four. For those four, the replacement cochlear implant (CI) performed well; the other patient fears pain if her replacement device is used, but continues enjoying her contralateral implant. At analysis by the company, two of five explanted devices exhibited problems: loss of hermeticity; insulation failure. Though infrequently reported, pain-only complaint by a CI user is a challenging dilemma. Pain may be the sole clinical manifestation of cochlear implant device failure. We offer a flowchart for the care of CI patients with pain, encourage a worldwide registry of such cases, and offer ideas to try to understand better the problem.

  6. Complex diagnosis in dental implantation and potentialities of predicting the results of treatment

    International Nuclear Information System (INIS)

    Matveeva, A.I.; Kulakov, A.A.

    1995-01-01

    Experience gained by the implantation Department of Central Research Institute of Dentistry in many years showed that comprehensive clinical and laboratory examinations, including roentgenological examination, functional diagnosis and examination of the immunity system help detect all unfavorable local and general factors. In patients referred to the risk group implantation is possible after preoperative treatment. Designing of STOM-1 and STOM-2, as well as of UMR-1 software helped carry our the calculations using IBM PC and determine the optimal type of the graft, place of its introduction, and number of grafts, as well as calculate the optimal design of the prosthesis

  7. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995)

    International Nuclear Information System (INIS)

    Edwards, M.R.; Egger, E.L.; Schwarz, P.D.

    1997-01-01

    Objective-To determine clinical signs, radiographic findings, results of surgical management, and potential causes of aseptic loosening of the femoral implant (ALFI) in dogs that have undergone cemented total hip arthroplasty (THA). Design-Retrospective study. Animals-11 cases of ALFI in 10 dogs. Procedure-Medical records of all dogs undergoing THA revision surgery were reviewed. Only dogs with ALFI were included. The prosthesis and cement were removed by creating a longitudinal osteotomy of the cranial femoral cortex. Postoperative radiographs of all dogs that underwent THA during the study period were reviewed. Results-The most common clinical sign was intermittent, subtle. or non-weight-bearing lameness. On radiographs obtained after THA, contact of the distal stem tip with cortical endosteum was evident in all dogs. Radiographic changes at the time of diagnosis of ALFI included asymmetric periosteal reaction along the femoral diaphysis, radiolucent lines between the prosthesis and cement, altered implant position, and femoral fracture. Surgical revision yielded good or excellent results in 9 cases. In 1 dog. the implant became infected; in another, aseptic loosening recurred. Aseptic loosening was significantly more common in dogs in which there was contact between the distal stem tip and cortical endosteum than in dogs in which there was no contact. Clinical Implications-ALFI is an uncommon, but important, complication of THA, and radiography is warranted in dogs with clinical signs of ALFI. Initial centering of the prosthetic stem within the femoral shaft may reduce the incidence of ALFI

  8. Failure analysis of fractured dental zirconia implants.

    Science.gov (United States)

    Gahlert, M; Burtscher, D; Grunert, I; Kniha, H; Steinhauser, E

    2012-03-01

    The purpose of the present study was the macroscopic and microscopic failure analysis of fractured zirconia dental implants. Thirteen fractured one-piece zirconia implants (Z-Look3) out of 170 inserted implants with an average in situ period of 36.75±5.34 months (range from 20 to 56 months, median 38 months) were prepared for macroscopic and microscopic (scanning electron microscopy [SEM]) failure analysis. These 170 implants were inserted in 79 patients. The patient histories were compared with fracture incidences to identify the reasons for the failure of the implants. Twelve of these fractured implants had a diameter of 3.25 mm and one implant had a diameter of 4 mm. All fractured implants were located in the anterior side of the maxilla and mandibula. The patient with the fracture of the 4 mm diameter implant was adversely affected by strong bruxism. By failure analysis (SEM), it could be demonstrated that in all cases, mechanical overloading caused the fracture of the implants. Inhomogeneities and internal defects of the ceramic material could be excluded, but notches and scratches due to sandblasting of the surface led to local stress concentrations that led to the mentioned mechanical overloading by bending loads. The present study identified a fracture rate of nearly 10% within a follow-up period of 36.75 months after prosthetic loading. Ninety-two per cent of the fractured implants were so-called diameter reduced implants (diameter 3.25 mm). These diameter reduced implants cannot be recommended for further clinical use. Improvement of the ceramic material and modification of the implant geometry has to be carried out to reduce the failure rate of small-sized ceramic implants. Nevertheless, due to the lack of appropriate laboratory testing, only clinical studies will demonstrate clearly whether and how far the failure rate can be reduced. © 2011 John Wiley & Sons A/S.

  9. Dislocation of cochlear implant magnet as a complication following MRI.

    Science.gov (United States)

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  10. Metastatic Breast Cancer in Medication-Related Osteonecrosis Around Mandibular Implants.

    Science.gov (United States)

    Favia, Gianfranco; Tempesta, Angela; Limongelli, Luisa; Crincoli, Vito; Piattelli, Adriano; Maiorano, Eugenio

    2015-09-15

    Many authors have considered dental implants to be unrelated to increased risk of medication-related osteonecrosis of the jaw (MRONJ). Nevertheless, more recently, more cases of peri-implant MRONJ (PI-MRONJ) have been described, thus becoming a challenging health problem. Also, metastatic cancer deposits are not infrequently found at peri-implant sites and this may represent an additional complication for such treatments. We present the case of a breast cancer patient with PI-MRONJ, presenting a clinically and radiologically undetected metastasis within the necrotic bone, and highlight the necessity of an accurate histopathological analysis. A 66-year-old female patient, who had received intravenous bisphosphonates for bone breast cancer metastases, came to our attention for a non-implant surgery-triggered PI-MRONJ. After surgical resection of the necrotic bone, conventional and immunohistochemical examinations were performed, which showed breast cancer deposits within the necrotic bone. Cancer patients with metastatic disease, who are undergoing bisphosphonate treatment, may develop unusual complications, including MRONJ, which is a site at risk for hosting additional metastatic deposits that may be clinically and radiologically overlooked. Such risk is increased by previous or concomitant implant procedures. Consequently, clinicians should be prudent when performing implant surgery in cancer patients with advanced-stage disease and consider the possible occurrence of peri-implant metastases while planning adequate treatments in such patients.

  11. Tailoring Selective Laser Melting Process Parameters for NiTi Implants

    Science.gov (United States)

    Bormann, Therese; Schumacher, Ralf; Müller, Bert; Mertmann, Matthias; de Wild, Michael

    2012-12-01

    Complex-shaped NiTi constructions become more and more essential for biomedical applications especially for dental or cranio-maxillofacial implants. The additive manufacturing method of selective laser melting allows realizing complex-shaped elements with predefined porosity and three-dimensional micro-architecture directly out of the design data. We demonstrate that the intentional modification of the applied energy during the SLM-process allows tailoring the transformation temperatures of NiTi entities within the entire construction. Differential scanning calorimetry, x-ray diffraction, and metallographic analysis were employed for the thermal and structural characterizations. In particular, the phase transformation temperatures, the related crystallographic phases, and the formed microstructures of SLM constructions were determined for a series of SLM-processing parameters. The SLM-NiTi exhibits pseudoelastic behavior. In this manner, the properties of NiTi implants can be tailored to build smart implants with pre-defined micro-architecture and advanced performance.

  12. Restoration: Implant with Devastated Platform through Metal Post

    Directory of Open Access Journals (Sweden)

    Luna Salinas Tatiana

    2017-01-01

    Full Text Available Case Presentation. Implant prostheses are a successful treatment for replacing missing teeth. However, this treatment modality can have biological and mechanical complications causing serious problems for the dentist, as demonstrated in this clinical case. The patient presented with a fractured screw and a severely damaged implant hex connection that corresponded to the second premolar, upper left, stating that she unsuccessfully tried to remove the prosthetic screw, which was most likely to have been loose. After clinical and radiographic review, it was decided to remove small fragments of the fractured prosthetic screw inside the implant head. Removal by conventional methods was unsuccessful but was eventually achieved through use of a bur. Then it was possible to make a cast post (gold-palladium and develop a fixed prosthesis (silver-palladium, which were attached with luting cement. A cast post (gold-palladium was made and a fixed prosthesis was developed (silver-palladium, which were attached with luting cement, the same ones that can present mechanical complications such as fractures between the third and fourth thread of the implant, loosening of the abutment, and/or the prosthetic screw in individual crowns, most frequently in partially edentulous patients, mainly in the premolar and molar regions of the maxilla. Conclusion. Therefore the present technique used in this case is very simple, noninvasive, and useful to readers.

  13. Patterns of failure after iodine-125 seed implantation for prostate cancer

    International Nuclear Information System (INIS)

    Lamb, David S.; Greig, Lynne; Russell, Grant L.; Nacey, John N.; Broome, Kim; Studd, Rod; Delahunt, Brett; Iupati, Douglas; Jain, Mohua; Rooney, Colin; Murray, Judy; Lamb, Peter J.; Bethwaite, Peter B.

    2014-01-01

    Purpose: To determine the site of relapse when biochemical failure (BF) occurs after iodine-125 seed implantation for prostate cancer. Materials and methods: From 2001–2009, 500 men underwent implantation in Wellington, New Zealand. Men who sustained BF were placed on relapse guidelines that delayed restaging and intervention until the prostate-specific antigen (PSA) was ⩾20 ng/mL. Results: Most implants (86%) had a prostate D90 of ⩾90%, and multivariate analysis showed that this parameter was not a variable that affected the risk of BF. Of 21 BFs that occurred, the site of failure was discovered to be local in one case and distant in nine cases. Restaging failed to identify the site of relapse in two cases. In nine cases the trigger for restaging had not been reached. Conclusions: If post-implant dosimetry is generally within the optimal range, distant rather than local failure appears to be the main cause of BF. Hormone treatment is therefore the most commonly indicated secondary treatment intervention (STI). Delaying the start of STI prevents the unnecessary treatment of men who undergo PSA ‘bounce’ and have PSA dynamics initially mimicking those of BF

  14. Maxillary implant-supported overdentures opposed by (partial) natural dentitions: a 5-year prospective case series study.

    Science.gov (United States)

    Boven, G C; Slot, J W A; Raghoebar, G M; Vissink, A; Meijer, H J A

    2017-12-01

    The aim of this study was to assess the 5-year treatment outcome of maxillary implant-retained overdentures opposed by natural antagonistic teeth. Fifty consecutive patients received maxillary overdentures supported by six dental implants. Implants were placed in the anterior region, if enough bone was present (n = 25 patients) Implant were placed in the posterior region if implant placement in the anterior region was not possible (n = 25 patients). Variables assessed included survival of implants, condition of hard and soft peri-implant tissues and patients' satisfaction. The five-year implant survival rate was 97·0% and 99·3%, and mean radiographic bone loss was 0·23 and 0·69 mm in the anterior and posterior group, respectively. Median scores for plaque, calculus, gingiva, bleeding and mean scores for pocket probing depth were low and stayed low. Patients' satisfaction after treatment was high in both groups. Within the limits of this 5-year study, it is concluded that six dental implants (placed in the anterior or posterior region) connected with a bar and opposed to natural antagonistic teeth result in acceptable results for clinical parameters and good outcomes for marginal bone level changes and patient satisfaction. © 2017 John Wiley & Sons Ltd.

  15. [A totally implantable venous access device. Implantation in general or local anaesthesia? A retrospective cost analysis].

    Science.gov (United States)

    Schuld, J; Richter, S; Moussavian, M R; Kollmar, O; Schilling, M K

    2009-08-01

    Implantation of venous access port systems can be performed in local or general anesthesia. In spite of the increasing rate of interventionally implanted systems, the surgical cut-down represents a safe alternative. Thus, the question arises whether--in context to the increasing health-economic pressure--open implantation in general anesthesia is still a feasible alternative to implantation in local anesthesia regarding OR efficiency and costs. In a retrospective analysis, 993 patients receiving a totally implantable venous access device between 2001 and 2007 were evaluated regarding OR utilization, turnover times, intraoperative data and costs. Implantations in local (LA) and general anesthesia (GA) were compared. GA was performed in 762 cases (76.6 %), LA was performed in 231 patients (23.3 %). Mean operation time was similar in both groups (LA 47.27 +/- 1.40 min vs. GA 45.41 +/- 0.75 min, p = 0.244). Patients receiving local anesthesia had a significantly shorter stay in the OR unit (LA 95.9 +/- 1.78 min vs. GA 105.92 +/- 0.92 min; p cut (LA 39.57 +/- 0.69 min vs. GA 50.46 +/- 0.52 min; p material costs were significantly lower in the LA group compared with the GA group (LA: 400.72 +/- 8.25 euro vs. GA: 482.86 +/- 6.23 euro; p systems in local anesthesia is superior in comparison to the implantation under general anesthesia regarding procedural times in the OR unit and costs. With the same operation duration, but less personnel and material expenditure, implantation in local anesthesia offers a potential economic advantage by permitting faster changing times. Implantation in GA only should be performed at a special request by the patient or in difficult venous conditions. Georg Thieme Verlag Stuttgart.New York.

  16. Does the Implantation Technique for Totally Implantable Venous Access Ports (TIVAPs) Influence Long-Term Outcome?

    Science.gov (United States)

    Biacchi, Daniele; Sammartino, Paolo; Sibio, Simone; Accarpio, Fabio; Cardi, Maurizio; Sapienza, Paolo; De Cesare, Alessandro; Atta, Joseph Maher Fouad; Impagnatiello, Alessio; Di Giorgio, Angelo

    2016-02-01

    Totally implantable venous access ports (TIVAP) are eventually explanted for various reasons, related or unrelated to the implantation technique used. Having more information on long-term explantation would help improve placement techniques. From a series of 1572 cancer patients who had TIVAPs implanted in our center with the cutdown technique or Seldinger technique, we studied the 542 patients who returned to us to have their TIVAP explanted after 70 days or more. As outcome measures we distinguished between TIVAPs explanted for long-term complications (infection, catheter-, reservoir-, and patient-related complications) and TIVAPs no longer needed. Univariate and multivariate analyses were run to investigate the reasons for explantation and their possible correlation with implantation techniques. The most common reason for explantation was infection (47.6 %), followed by catheter-related (20.8 %), patient-related (14.7 %), and reservoir-related complications (4.7 %). In the remaining 12.2 % of cases, the TIVAP was explanted complication free after the planned treatments ended. Infection correlated closely with longer TIVAP use. Univariate and multivariate analyses identified the Seldinger technique as a major risk factor for venous thrombosis and catheter dislocation. The need for long-term TIVAP explantation in about one-third of cancer patients is related to the implantation techniques used.

  17. Cortical Plasticity after Cochlear Implantation

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Gjedde, Albert; Wallentin, Mikkel

    2013-01-01

    recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners...... with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss...... occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only...

  18. Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports

    DEFF Research Database (Denmark)

    Enggaard, Thomas P; Andersen, Claus; Scherer, Christian

    2010-01-01

    Patients implanted with a cardioverter defibrillator (ICD) who are suffering from refractory angina pectoris could benefit from spinal cord stimulation (SCS) due to the well-documented pain relieving effect. However, the combined treatment remains controversial. The aim of the study is to report...... successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators. The combined treatments with ICD and thoracic epidural electrical stimulation were used in five patients with refractory angina pectoris. During the procedure of the implantation, testing with the maximal...... for refractory angina pectoris can be performed in patients implanted with cardioverter defibrillators without interference. However, individual testing during implantation or re-programming the devices is mandatory in order to assess optimal safety in each patient....

  19. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    Science.gov (United States)

    Okada, Shinsuke; Koretake, Katsunori; Miyamoto, Yasunari; Oue, Hiroshi; Akagawa, Yasumasa

    2013-01-01

    The aim of this study was to evaluate whether increased crown-to-implant (C/I) ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. Five male Beagle-Labrador hybrid dogs (2 years old) were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week). Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. Implant stability quotient (ISQ) increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05). Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05). Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  20. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    Directory of Open Access Journals (Sweden)

    Shinsuke Okada

    Full Text Available OBJECTIVE: The aim of this study was to evaluate whether increased crown-to-implant (C/I ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. MATERIALS AND METHODS: Five male Beagle-Labrador hybrid dogs (2 years old were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week. Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. RESULT: Implant stability quotient (ISQ increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05. Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05. Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. CONCLUSION: These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  1. Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants.

    Science.gov (United States)

    Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E

    2008-07-01

    The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.

  2. Delayed-onset streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Bayraktar, Zerrin; Kapran, Ziya; Bayraktar, Sükrü; Acar, Nur; Unver, Yaprak Banu; Gök, Kemran

    2005-01-01

    To report a case of delayed-onset Streptococcus pyogenes endophthalmitis following implantation of an Ahmed glaucoma valve. A 10-year-old patient presented with acute endophthalmitis 1 year after Ahmed glaucoma valve implantation. The conjunctiva and Tenon's capsule over the valve plate had been penetrated by one of the polypropylene fixation sutures. The valve was removed, and pars plana vitrectomy was performed. Vitreous specimens and removal of the discharge over the plate revealed Streptococcus pyogenes. This is the first documented case of Streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation. We think the conjunctival buttonhole caused by the polypropylene suture provided an entry site for the infection. (c) Japanese Ophthalmological Society 2005.

  3. Cochlear implant after bacterial meningitis.

    Science.gov (United States)

    Bille, Jesper; Ovesen, Therese

    2014-06-01

    The aim of this retrospective case study at a tertiary referral center was to investigate the outcome of cochlear implantation (CI) in children with sensorineural hearing loss due to meningitis compared to CI in children with deafness due to other reasons. This post-meningial group (PMG) consisted of 22 children undergoing CI due to deafness induced by meningitis, between December 1996 and January 2012. Five children had bilateral simultaneous implantation. None was excluded and the children were followed for at least 3 years. Operations were carried out by one of two surgeons using similar techniques in all cases. Each patient from the PMG was matched 2:1 with children having implantation for other reasons according to age and follow up (control group). Overall, the median category of auditory performance (CAP) and speech intelligibility rating (SIR) score were not statistically significantly different between the two groups. The presence of additional central nervous system (CNS) disorders (post-meningeal sequelae), however, correlated significantly with poorer outcome CI was a safe procedure without surgical complications in the present study. It is possible to restore auditory capacity and speech performance to a degree comparable to children undergoing implantation for other reasons. A statistically important variable is secondary CNS involvement. The rehabilitation program after CI should be adjusted according to these additional handicaps. It is recommended to screen meningitis patients as fast as possible to identify those with hearing loss and initiate treatment with hearing aids or CI. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  4. Analysis of incidence and related factors on effusion of anterior chamber after phacoemulsification combined with intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Bing-Bing Zhao

    2018-02-01

    Full Text Available AIM: To investigate the incidence and related factors on effusion of anterior chamber(ACafter phacoemulsification(PEcombined with intraocular lens(IOLimplantation. METHODS: Totally 359 cases of cataract(375 eyesunderwent PE combined with IOL implantation were collected in our hospital. The incidence of AC exudation after operation and related factors were analyzed by single factor and multiple logistic regression analysis. RESULTS: The group was included in 359 cases(375 eyes. The incidence of postoperative AC exudation in the study group was 5.9%(22/375. The preoperative intraocular pressure(IOP, visual acuity before and after surgery, nuclear grades, posterior capsular rupture(PCRrate and ultrasonic accumulated energy complex parameter(AECPof the study group showed statistically significant difference compared with the control group(all P21mmHg, intraoperative pupil diameter 7.25(%×min, the lens nucleus grade ≥ IV were risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all P21mmHg, ultrasound AECP >7.25 were independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract(all PCONCLUSION: High myopia, glaucoma, uveitis, the lens nucleus grade ≥ IV, the incidence of intraoperative PCR, preoperative IOP>21mmHg, ultrasonic AECP>7.25 are independent risk factors of AC exudation after PE combined with IOL implantation in patients with cataract, with such risk factors in patients with cataract should be paid closely attention and timely diagnosis and treatment in clinic.

  5. Interstitial vaginal needle implantation in gynecological tumors : design and construction of applicator

    International Nuclear Information System (INIS)

    Kang, Seung Hee; Chun, Mi Son; Kang, Hae Jin; Jung, Chil; Son, Jeong Hyae

    1998-01-01

    It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or single plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases)or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a single plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to mprove tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material(Provil). The applicators were customized individually according to the tumor size and its location. Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron, Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant prodecure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal

  6. Linguine sign in musculoskeletal imaging: calf silicone implant rupture.

    Science.gov (United States)

    Duryea, Dennis; Petscavage-Thomas, Jonelle; Frauenhoffer, Elizabeth E; Walker, Eric A

    2015-08-01

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition.

  7. Biomechanical implant treatment complications: a systematic review of clinical studies of implants with at least 1 year of functional loading.

    Science.gov (United States)

    Hsu, Yung-Ting; Fu, Jia-Hui; Al-Hezaimi, Khalid; Wang, Hom-Lay

    2012-01-01

    The aim of this article is to discuss the current literature available on the etiology and management of biomechanical complications of dental implant treatment. An electronic search of the PubMed database for English-language articles published before May 31, 2011, was performed based on a focus question: "How can biomechanical implant treatment complications be managed and identified?" The key words used were "dental implant," "etiology," "management," "excessive occlusal forces," "occlusal forces," "occlusion," "parafunctional habits," "biomechanical failure," "biomechanical complications," and "occlusal overloading." Clinical trials with a minimum of 10 implants followed for at least 1 year after functional loading were included. The initial electronic search identified 2,087 publications, most of which were eliminated, as they were animal studies, finite element analyses, bench-top studies, case reports, and literature reviews. After the titles, abstracts, and full text of 39 potentially eligible publications were reviewed, 15 studies were found to fulfill the inclusion criteria. Occlusal overloading was thought to be the primary etiologic factor in biomechanical implant treatment complications, which commonly included marginal bone loss, fracture of resin/ceramic veneers and porcelain, retention device or denture base fracture of implant-supported overdentures, loosening or fracture of abutment screws, and even implant failure. Occlusal overloading was positively associated with parafunctional habits such as bruxism. An appreciation of the intricacy of implant occlusion would allow clinicians to take a more preventive approach when performing implant treatment planning, as avoidance of implant overloading helps to ensure the long-term stability of implant-supported prostheses.

  8. Metal ion implantation: Conventional versus immersion

    International Nuclear Information System (INIS)

    Brown, I.G.; Anders, A.; Anders, S.; Dickinson, M.R.; MacGill, R.A.

    1994-01-01

    Vacuum-arc-produced metal plasma can be used as the ion feedstock material in an ion source for doing conventional metal ion implantation, or as the immersing plasma for doing plasma immersion ion implantation. The basic plasma production method is the same in both cases; it is simple and efficient and can be used with a wide range of metals. Vacuum arc ion sources of different kinds have been developed by the authors and others and their suitability as a metal ion implantation tool has been well established. Metal plasma immersion surface processing is an emerging tool whose characteristics and applications are the subject of present research. There are a number of differences between the two techniques, both in the procedures used and in the modified surfaces created. For example, the condensibility of metal plasma results in thin film formation and subsequent energetic implantation is thus done through the deposited layer; in the usual scenario, this recoil implantation and the intermixing it produces is a feature of metal plasma immersion but not of conventional energetic ion implantation. Metal plasma immersion is more suited (but not limited) to higher doses (>10 17 cm -2 ) and lower energies (E i < tens of keV) than the usual ranges of conventional metal ion implantation. These and other differences provide these vacuum-arc-based surface modification tools with a versatility that enhances the overall technological attractiveness of both

  9. Bruxism and Dental Implants: A Meta-Analysis.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-10-01

    To test the null hypothesis of no difference in the implant failure rates, postoperative infection, and marginal bone loss after the insertion of dental implants in bruxers compared with the insertion in non-bruxers against the alternative hypothesis of a difference. An electronic search was undertaken in June 2014. Eligibility criteria included clinical studies, either randomized or not. Ten publications were included with a total of 760 implants inserted in bruxers (49 failures; 6.45%) and 2989 in non-bruxers (109 failures; 3.65%). Due to lack of information, meta-analyses for the outcomes "postoperative infection" and "marginal bone loss" were not possible. A risk ratio of 2.93 was found (95% confidence interval, 1.48-5.81; P = 0.002). These results cannot suggest that the insertion of dental implants in bruxers affects the implant failure rates due to a limited number of published studies, all characterized by a low level of specificity, and most of them deal with a limited number of cases without a control group. Therefore, the real effect of bruxing habits on the osseointegration and survival of endosteal dental implants is still not well established.

  10. Study of thermal treated a-Si implanted with Er and O ions

    CERN Document Server

    Plugaru, R; Piqueras, J; Tate, T J

    2002-01-01

    Visible luminescence of amorphous silicon layers either implanted with Er or co-implanted with Er and O and subsequently annealed in nitrogen has been investigated by cathodoluminescence (CL) in a scanning electron microscope. Co-implanted samples show a more intense luminescence, which is revealed by annealing at lower temperatures than the samples implanted only with erbium. Thermal treatments cause the formation of erbium oxide as well as Er-Si complexes or precipitates. Violet-blue luminescence has been found from CL images and spectra to be related to Er-Si precipitates. Emission in the green-red range is attributed to oxide species.

  11. Volumetric changes and peri-implant health at implant sites with or without soft tissue grafting in the esthetic zone, a retrospective case-control study with a 5-year follow-up.

    Science.gov (United States)

    Bienz, Stefan P; Jung, Ronald E; Sapata, Vitor M; Hämmerle, Christoph H F; Hüsler, Jürg; Thoma, Daniel S

    2017-11-01

    To evaluate the volumetric changes and peri-implant health at implant sites with and without previous soft tissue grafting over a 5-year observation period. In 18 partially edentulous patients, dental implants were placed in the esthetic zone (15-25) with simultaneous guided bone regeneration, followed by submerged healing. During the healing phase, eight patients (test) received a subepithelial connective tissue graft, whereas 10 patients (control) did not receive any soft tissue augmentation. Subsequently, abutment connection was performed and final reconstructions were inserted. Impressions were taken 1 week after crown insertion and at 5 years. Obtained casts were scanned and superimposed for volumetric and linear measurements. The mean distance (MD) in the mid-buccal area between the two surfaces and the differences in buccal marginal mucosal level (bMML change ) and in ridge width (RW change ) were evaluated. Peri-implant health was assessed using probing pocket depth (PPD) values, plaque index (PlI) and bleeding on probing (BOP). At a median follow-up time of 60.5 months a median MD of -0.38 mm (Min: -0.94; Max: -0.03) (test) and of -0.51 mm (Min: -0.76; Max: 0.05) (control) was calculated. The level of the margo mucosae (bMML change ) demonstrated a median loss of -0.42 mm (Min: -1.1; Max: -0.01) (test) and of -0.33 mm (Min: -1.02; Max: 0.00) (control). The median RW change ranged between -0.44 mm and -0.73 mm (test) and between -0.49 mm and -0.54 mm (control). Mean PPD values slightly increased, whereas PlI and BOP remained stable over time in both groups. None of the comparisons between the groups revealed statistically significant differences (P > 0.35). A small sample size must be considered, however. Limited by a retrospective case-control study design, implant sites with and without soft tissue grafting on the buccal side revealed only minimal volumetric and linear changes and stability of peri-implant parameters over 5 years. © 2017

  12. Biomechanical optimization of implant diameter and length for immediate loading: a nonlinear finite element analysis.

    Science.gov (United States)

    Kong, Liang; Gu, Zexu; Li, Tao; Wu, Junjie; Hu, Kaijin; Liu, Yanpu; Zhou, Hongzhi; Liu, Baolin

    2009-01-01

    A nonlinear finite element method was applied to examine the effects of implant diameter and length on the maximum von Mises stresses in the jaw, and to evaluate the maximum displacement of the implant-abutment complex in immediate-loading models. The implant diameter (D) ranged from 3.0 to 5.0 mm and implant length (L) ranged from 6.0 to 16.0 mm. The results showed that the maximum von Mises stress in cortical bone was decreased by 65.8% under a buccolingual load with an increase in D. In cancellous bone, it was decreased by 71.5% under an axial load with an increase in L. The maximum displacement in the implant-abutment complex decreased by 64.8% under a buccolingual load with an increase in D. The implant was found to be more sensitive to L than to D under axial loads, while D played a more important role in enhancing its stability under buccolingual loads. When D exceeded 4.0 mm and L exceeded 11.0 mm, both minimum stress and displacement were obtained. Therefore, these dimensions were the optimal biomechanical selections for immediate-loading implants in type B/2 bone.

  13. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  14. Immediate vs. delayed endosseous integration of maxi implants: a torque removal animal study

    Directory of Open Access Journals (Sweden)

    Hanif Allahbakhshi

    2017-06-01

    Full Text Available Background. Delayed loading is one of the concerns in implant patients. Immediate loading can solve the problem and make patients more satisfied. The present study aimed to compare the removal torque of maxi implants under different loading (immediate and delayed patterns. Methods. This split-mouth experimental study included 2 dogs. Impressions were made and then all the premolars were extracted under general anesthesia. After a three-month healing period, 3 implants were inserted in each quadrant (a total of 12 implants. Anterior and posterior implants (the case group were splinted by an acrylic temporary bridge in order to make the middle implants (the control group off the occlusion. The dogs were sacrificed after 6 weeks and bone blocks were submitted for removal torque test. Data were analyzed with ANOVA (P<0.05. Results. Mean torque values for the cases and control groups were 46.82±25.58 and 59.88±15.19, respectively (P=0.582; not significant. Conclusion. It may be concluded that immediate loading does not reduce the reverse torque values of maxi implants. This supports the advantages of immediate loading for maxi implants.

  15. Autologous Chondrocyte Implantation in Osteoarthritic Surroundings

    DEFF Research Database (Denmark)

    Ossendorff, Robert; Grad, Sibylle; Stoddart, Martin J

    2018-01-01

    BACKGROUND: Autologous chondrocyte implantation (ACI) fails in up to 20% of cases. Advanced intra-articular degeneration paired with an inflammatory environment may be closely related to implantation failure. Certain cytokines have been identified to play a major role during early osteoarthritis....... PURPOSE: To investigate the effects of tumor necrosis factor α (TNFα) and its potential inhibition by adalimumab on cartilage regeneration in an in vitro model of ACI. STUDY DESIGN: Controlled laboratory study. METHODS: Bovine articular chondrocytes were cultivated and transferred at passage 3 to fibrin...

  16. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  17. [MR implant labelling and its use in clinical MRI practice].

    Science.gov (United States)

    Mühlenweg, M; Schaefers, G

    2015-08-01

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application.

  18. MR implant labelling and its use in clinical MRI practice

    International Nuclear Information System (INIS)

    Muehlenweg, M.; Schaefers, G.

    2015-01-01

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application. (orig.) [de

  19. What Does Music Sound Like for a Cochlear Implant User?

    Science.gov (United States)

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  20. Utilization of 3D/Dental software for precise implant site selection: clinical reports.

    Science.gov (United States)

    Kraut, R A

    1992-01-01

    Preoperative planning is an essential aspect of endosteal implant placement. Three-dimensional imaging allows the surgeon and restorative dentist to accurately visualize potential implant receptor sites relative to adjacent vital structures. This information is correlated with the planned occlusion, and transferred to the patient by means of a surgical prosthetic guide, which is developed on the diagnostic cast. The steps involved in planning and placing implants in an atrophic mandible in the first case illustrates the value of three-dimensional scanning in treating patients with limited bone volume. The second case presented with a mandibular bilateral distal extension partial denture, which was ultimately replaced with two implant-supported fixed prostheses. The use of three-dimensional imaging showed the location of the inferior alveolar neurovascular bundle which allowed utilization of all of the bone above it without encroaching on the nerve. The third case illustrates an edentulous maxilla where visualization of the osseous contour allowed for implant placement at an optimal angulation to provide support for the planned prosthesis.