WorldWideScience

Sample records for complete chromatographic separation

  1. Optimization of the gas chromatographic separations

    International Nuclear Information System (INIS)

    Gasco Sanchez, L.

    1973-01-01

    A review and a critical study on the optimization of the gas chromatographic separations are made. After dealing with the fundamental gas chromatographic equations, some methods of expressing column performances are discussed: performance indices, performance parameters, resolution and effective plate number per unit time. This is completed with a comparative study on performances of various types of columns. Moreover, optimization methods for operating chromatographic conditions are extensively dealt with: as resolution optimization, separation time, and normalization techniques for the time of analysis in order to achieve the maximum resolution at constant time. Finally, some others non operating parameters such as: selectivity of stationary phases, column preparation and optimization methods by means of computers are studied. (Author) 68 refs

  2. Chromatographic separations of stereoisomers

    Energy Technology Data Exchange (ETDEWEB)

    Souter, R.W.

    1985-01-01

    This text covers both diastereomers and enantiomers; describes techniques for GC, HPLC, and other chromatographic methods; and tabulates results of various applications by both techniques and compound class. It provides current knowledge about separation mechanisms and interactions of asymmetric molecules, as well as experimental and commercial materials such as columns, instruments, and derivatization reagents. The contents also include stereoisomer separations by gas chromatography. Stereoisomer separations by high-performance liquid chromatography. Stereoisomer separations by other chromatographic techniques.

  3. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1983-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure, particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  4. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1981-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure , particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  5. Isotope separations using chromatographic methods

    International Nuclear Information System (INIS)

    Leseticky, L.

    1985-01-01

    A survey is given of chromatographic separations of compounds only differing in isotope composition. Isotope effects on physical properties which allow chromatographic separation (vapour tension, adsorption heat, partition coefficient) are very small, with the exception of the simplest molecules. Therefore, separation factors only assume the value of several per cent. From this ensues the necessity of using columns which are specially and very carefully prepared and have a separation efficiency of the order of 10 4 theoretical plates. Briefly discussed is liquid chromatography on ion exchangers which with a varied degree of success was used for separating simple inorganic compounds or ions. Ion exchange chromatography of amino acids labelled with tritium, and chromatography of tritium labelled steroids also provided only a certain degree of separation. A detailed analysis is presented of gas chromatography separation of various deuterium and tritium labelled low-molecular compounds, to which a number of studies has been devoted in the literature. Very promising is the method of complexation gas chromatography based on the reversible formation of a complex of the ligand (the compound being separated) and the compound of the (transition) metal as the steady-state phase. (author)

  6. Effect of chromatographic separation on ASP system interface tension and the countermeasures

    Directory of Open Access Journals (Sweden)

    Jiawei REN

    2016-06-01

    Full Text Available Because of the existing chromatographic separation phenomenon, ASP flooding changes original nature of the system. Therefore, in laboratory ultra-low interfacial tension ASP system is preferred for sand packs flow experiment to research on the effect of chromatographic separation on ASP system interface tension. The two parameters of "breakthrough time" and "output difference" are used to describe the degree of chromatographic separation, and the produced fluid interfacial tensions at the outlet end at 120 min is measured. The research shows that there exists chromatographic separation between three chemicals of ASP system, with first polymer breakthrough and finally surfactant breakthrough; there is most serious chromatographic separation between surfactant and polymer, while minimum chromatographic separation between alkali and polymer; chromatographic separation makes ASP interfacial tension increase from 10-3 magnitude to 10-2 magnitude, affecting flooding effect of ASP system. Thus, reducing the loss of surfactant in the formation will be the main measure to reduce the degree of chromatographic separation. Using sophorolipid as sacrificial agent to replace part of the surfactant injected into formation before ASP system can effectively reduce the impact of chromatography separation and more effectively improve the ultimate recovery ratio.

  7. Optimization of the gas chromatographic separations; Optimacion de las separaciones cromatograficas en fase gaseosa

    Energy Technology Data Exchange (ETDEWEB)

    Gasco Sanchez, L

    1973-07-01

    A review and a critical study on the optimization of the gas chromatographic separations are made. After dealing with the fundamental gas chromatographic equations, some methods of expressing column performances are discussed: performance indices, performance parameters, resolution and effective plate number per unit time. This is completed with a comparative study on performances of various types of columns. Moreover, optimization methods for operating chromatographic conditions are extensively dealt with: as resolution optimization, separation time, and normalization techniques for the time of analysis in order to achieve the maximum resolution at constant time. Finally, some others non operating parameters such as: selectivity of stationary phases, column preparation and optimization methods by means of computers are studied. (Author) 68 refs.

  8. Amalgam-chromatographic separation of magnesium isotopes

    International Nuclear Information System (INIS)

    Klinskij, G.D.; Levkin, A.V.; Ivanov, S.A.

    1990-01-01

    Separation of magnesium isotopes within Mg(Hg)-MgI 2 system (in dimethylformamide) is conducted under amalgam-chromatographic conditions. Separation maximal degree, that is (1.09), for 24 Mg and 26 Mg and separation coefficient (α = 1.0089±0.006) are determined. Light isotopes are found to concentrate in the amalgam. Technique of thermal conversion of flows within amalgam-dimethylformamide system is suggested on the basis of reversible reaction of Ca-Mg element exchange

  9. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    Science.gov (United States)

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  10. Industrial scale chromatographic separation of valuable compounds from biomass hydrolysates and side streams

    Energy Technology Data Exchange (ETDEWEB)

    Saari, P.

    2011-06-15

    Carbohydrates are composed of a number of various monosaccharides, glucose being the most abundant. Some of the monosaccharides are valuable compounds used in the food and pharmaceutical industries. They can be separated from biomass hydrolysates e.g. by chromatographic methods. In this thesis, chromatographic separation of valuable compounds using ion exchange resins was studied on an industrial scale. Of special interest were rare monosaccharides in biomass hydrolysates. A novel chromatographic separation process was developed for fucose, starting from pre-processed spent sulfite liquor. The core of the process consists of three chromatographic separations with different types of ion exchange resins. Chromatographic separation of galactose was tested with three biomass hydrolysates; lactose, gum arabic and hemicellulose hydrolysates. It was demonstrated that also galactose can be separated from complex carbohydrate mixtures. A recovery process for arabinose from citrus pectin liquid residual and for mannose from wood pulp hydrolysate were also developed and experimentally verified. In addition to monosaccharides, chromatographic separation of glycinebetaine from vinasse was examined with a hydrogen form weak acid cation exchange resin. The separation involves untypical peak formation depending, for example, on the pH and the cation composition. The retention mechanism was found to be hydrogen bonding between glycinebetaine and the resin. In the experimental part, all four resin types - strong acid cation, strong base anion, weak acid cation and weak base anion exchange resins - were used. In addition, adsorption equilibria data of seven monosaccharides and sucrose were measured with the resins in sodium and sulfate forms because such data have been lacking. It was found out that the isotherms of all sugars were linear under industrial conditions. A systematic method for conceptual process design and sequencing of chromatographic separation steps were developed

  11. Gas-chromatographic separation of hydrogen isotopic mixtures

    International Nuclear Information System (INIS)

    Preda, Anisoara; Bidica, Nicolae

    2005-01-01

    Full text: Gas chromatographic separation of hydrogen isotopes have been reported in the literature since late of 1950's. Gas chromatography is primarily an analytical method, but because of its properties it may be used in many other fields with excellent results. A simple method is proposed for the gas-chromatographic analysis of complex gas mixtures containing hydrogen isotopes; the method is based on the substantial difference in the thermal conductivity of these isotopes. One of the main disadvantages of the conventional gas chromatography is the long retention times required for the analysis of hydrogen gas mixtures while the column is operated at very low temperature. The method described in this paper was based on using a capillary molecular sieve 5A column operated for this kind of separation at 173 K. The carrier gas was Ne and the detector was TCD. In the paper chromatograms for various carrier flow rates and various hydrogen isotope mixtures are presented. (authors)

  12. Use of coextraction and suppression of extraction in extraction-chromatographic separation of elements

    International Nuclear Information System (INIS)

    Karandashev, V.K.; Kuznetsov, R.A.; Grazhulene, S.S.; Usmanova, M.M.

    1988-01-01

    TBP, solutions of hydrobromic acid, indium and polytetrafluoroethylene powder, carrier for TBP, were used to study the effects of coextraction and extraction suppression on extraction-chromatographic behaviour of microamounts of elements in the presence of macroamounts of other elements. Possibility of using these effects under extraction-chromatographic element separation were considered. A new method for extraction-chromatographic separation of scandium microamounts from the mixture of large amount of elements (Y, Cd, Ce, Eu, Lu, Hf, Ta, W, Np and other) was suggested. 15 refs.; 3 figs

  13. Chiral ionic liquids in chromatographic and electrophoretic separations.

    Science.gov (United States)

    Kapnissi-Christodoulou, Constantina P; Stavrou, Ioannis J; Mavroudi, Maria C

    2014-10-10

    This report provides an overview of the application of chiral ionic liquids (CILs) in separation technology, and particularly in capillary electrophoresis and both gas and liquid chromatography. There is a large number of CILs that have been synthesized and designed as chiral agents. However, only a few have successfully been applied in separation technology. Even though this application of CILs is still in its early stages, the scientific interest is increasing dramatically. This article is focused on the use of CILs as chiral selectors, background electrolyte additives, chiral ligands and chiral stationary phases in electrophoretic and chromatographic techniques. Different examples of CILs, which contain either a chiral cation, a chiral anion or both, are presented in this review article, and their major advantages along with their potential applications in chiral electrophoretic and chromatographic recognition are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. The gas-chromatographic and gas-chromatographic-mass-spectrometric identification of halogen-containing organic compounds

    Science.gov (United States)

    Gidaspov, B. V.; Zenkevich, I. G.; Rodin, A. A.

    1989-09-01

    The problem of identifying halogen-containing organic compounds in their gas-chromatographic and gas-chromatographic-mass-spectrometric (GC-MS) determination in different materials has been examined. Particular attention has been paid not to the complete characterisation of methods for carrying out this analysis but to the most important problem of increasing the selectivity at the stages of sampling, separation, and interpretation of the gas-chromatographic and GC-MS information. The bibliography contains 292 references.

  15. Chromatographic Separations of Enantiomers and Underivatized Oligosaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ying [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    My graduate research has focused on separation science and bioanalytical analysis, which emphasized in method development. It includes three major areas: enantiomeric separations using high performance liquid chromatography (HPLC), Super/subcritical fluid chromatography (SFC), and capillary electrophoresis (CE); drug-protein binding behavior studies using CE; and carbohydrate analysis using liquid chromatograph-electrospray ionization mass spectrometry (LC-ESI-MS). Enantiomeric separations continue to be extremely important in the pharmaceutical industry. An in-depth evaluation of the enantiomeric separation capabilities of macrocyclic glycopeptides CSPs with SFC mobile phases was investigated using a set of over 100 chiral compounds. It was found that the macrocyclic based CSPs were able to separate enantiomers of various compounds with different polarities and functionalities. Seventy percent of all separations were achieved in less than 4 min due to the high flow rate (4.0 ml/min) that can be used in SFC. Drug-protein binding is an important process in determining the activity and fate of a drug once it enters the body. Two drug/protein systems have been studied using frontal analysis CE method. More sensitive fluorescence detection was introduced in this assay, which overcame the problem of low sensitivity that is common when using UV detection for drug-protein studies. In addition, the first usage of an argon ion laser with 257 nm beam coupled with CCD camera as a frontal analysis detection method enabled the simultaneous observation of drug fluorescence as well as the protein fluorescence. LC-ESI-MS was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 picograms, all individual components of oligosaccharide mixtures (up to 11 glucose-units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. This system is characterized by high chromatographic

  16. Chromatographic Separations of Enantiomers and Underivatized Oligosaccharides

    International Nuclear Information System (INIS)

    Ying Liu

    2004-01-01

    My graduate research has focused on separation science and bioanalytical analysis, which emphasized in method development. It includes three major areas: enantiomeric separations using high performance liquid chromatography (HPLC), Super/subcritical fluid chromatography (SFC), and capillary electrophoresis (CE); drug-protein binding behavior studies using CE; and carbohydrate analysis using liquid chromatograph-electrospray ionization mass spectrometry (LC-ESI-MS). Enantiomeric separations continue to be extremely important in the pharmaceutical industry. An in-depth evaluation of the enantiomeric separation capabilities of macrocyclic glycopeptides CSPs with SFC mobile phases was investigated using a set of over 100 chiral compounds. It was found that the macrocyclic based CSPs were able to separate enantiomers of various compounds with different polarities and functionalities. Seventy percent of all separations were achieved in less than 4 min due to the high flow rate (4.0 ml/min) that can be used in SFC. Drug-protein binding is an important process in determining the activity and fate of a drug once it enters the body. Two drug/protein systems have been studied using frontal analysis CE method. More sensitive fluorescence detection was introduced in this assay, which overcame the problem of low sensitivity that is common when using UV detection for drug-protein studies. In addition, the first usage of an argon ion laser with 257 nm beam coupled with CCD camera as a frontal analysis detection method enabled the simultaneous observation of drug fluorescence as well as the protein fluorescence. LC-ESI-MS was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 picograms, all individual components of oligosaccharide mixtures (up to 11 glucose-units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. This system is characterized by high chromatographic

  17. Large scale chromatographic separations using continuous displacement chromatography (CDC)

    International Nuclear Information System (INIS)

    Taniguchi, V.T.; Doty, A.W.; Byers, C.H.

    1988-01-01

    A process for large scale chromatographic separations using a continuous chromatography technique is described. The process combines the advantages of large scale batch fixed column displacement chromatography with conventional analytical or elution continuous annular chromatography (CAC) to enable large scale displacement chromatography to be performed on a continuous basis (CDC). Such large scale, continuous displacement chromatography separations have not been reported in the literature. The process is demonstrated with the ion exchange separation of a binary lanthanide (Nd/Pr) mixture. The process is, however, applicable to any displacement chromatography separation that can be performed using conventional batch, fixed column chromatography

  18. Chromatographic separation of europium and gadolinum mixtures by ethylenediaminedisuccinic acid

    International Nuclear Information System (INIS)

    Kolleganov, M.Yu.; Nazarov, P.P.; Martynenko, L.I.; Mtrofanova, N.D.; Spitsyn, V.I.

    1985-01-01

    Comparative investigation of chromatographic separation of impurities of Eu and Gd micro- and macroquantities by means of ethylenediaminedisuccinic (EDDS) and ethylene-diaminetetraacetic (EDTA) acids is performed. It is shown that EDTA is a sufficiently effective agent for separation of this pair of elements. The values of EU and Gd separation coefficients obtained in experiments with RE microquantities are not realized at Eu-Gd, macroquantities separation which probably is connected with the influence of polymerization processes in the systems containing RE and EDDS complexes

  19. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    Science.gov (United States)

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  20. Investigations for chromatographic separation and determination of the rare earths and auxiliary group elements

    International Nuclear Information System (INIS)

    Post, K.

    1981-01-01

    Different method have been developed to quantitatively determine rare earth elements after their column chromatographic separation. The influence of the active solvents in the running systems diethyl ether/tetra hydrofuran (THF)/nitric acid (HNO 3 ) and diethyl ether/bis-(2-ethyl hexyl) phosphate (HDEHP)/HNO 3 was investigated on the column chromatographic separation of all rare earth elements is possible by the synergistic combination of the active running components THF and HDEHP. Further from product isotopes could also be separated using the running agents described here in investigations to separate fission product mixtures of irradiated uranium. (orig./HBR) [de

  1. Chromatographic separation of Iodine species for environmental studies

    Energy Technology Data Exchange (ETDEWEB)

    Machado, E.C. [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Geoquimica]. E-mail: geoedin@vm.uff.br; Bellido, A.V.B. [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Fisico-Quimica]. E-mail: alf@risc2.rmn.uff.br; Bellido, L.F. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)]. E-mail: lbellido@cnen.gov.br

    1999-07-01

    In this work a experimental method was developed to separate iodine species from environmental samples by using adsorption chromatography. The radionuclide {sup 123} I which has a half-life of 13 h and a convenient gamma ray of 159 keV was used to investigate a fast and efficient procedure for the separation of iodide and iodate ions in seawater from mangrove samples. The radio-iodine tracer technique is very useful, particularly in kinetic studies because it is easy to detect without any interference of concentration due to the small amount of tracer that is spiked. It is also possible to add two tracers (I-123 and I-131) in different oxidation states. Three chromatographic methods were studied: paper, thin layer and adsorption chromatography with silica and alumina. It was found that paper chromatography is very useful for checking the valence adjustment of the radioiodine species. Initially, several coefficient distributions of iodine species by adsorption in silica and alumina from NaOH, NaHCO{sub 3} and NaNO{sub 3} solutions (in the range 05. - 0.0001 m) were determined. The best separation so far was achieved by loading the sample (after adjusting the concentration to 0.1 NNaNO{sub 3}) into a chromatographic column with Al{sub 2} O{sub 3}. The iodide passes through the column and after washing the column, the iodate was removed by eluting with 1.0 M NaHCO{sub 3} solution. (author)

  2. Chromatographic separation of Iodine species for environmental studies

    International Nuclear Information System (INIS)

    Machado, E.C.

    1999-01-01

    In this work a experimental method was developed to separate iodine species from environmental samples by using adsorption chromatography. The radionuclide 123 I which has a half-life of 13 h and a convenient gamma ray of 159 keV was used to investigate a fast and efficient procedure for the separation of iodide and iodate ions in seawater from mangrove samples. The radio-iodine tracer technique is very useful, particularly in kinetic studies because it is easy to detect without any interference of concentration due to the small amount of tracer that is spiked. It is also possible to add two tracers (I-123 and I-131) in different oxidation states. Three chromatographic methods were studied: paper, thin layer and adsorption chromatography with silica and alumina. It was found that paper chromatography is very useful for checking the valence adjustment of the radioiodine species. Initially, several coefficient distributions of iodine species by adsorption in silica and alumina from NaOH, NaHCO 3 and NaNO 3 solutions (in the range 05. - 0.0001 m) were determined. The best separation so far was achieved by loading the sample (after adjusting the concentration to 0.1 NNaNO 3 ) into a chromatographic column with Al 2 O 3 . The iodide passes through the column and after washing the column, the iodate was removed by eluting with 1.0 M NaHCO 3 solution. (author)

  3. Supercritical Fluid Chromatographic Separation of Dimethylpolysiloxane Polymer

    Energy Technology Data Exchange (ETDEWEB)

    Pyo, Dong Jin; Lim, Chang Hyun [Kangwon National University, Chuncheon (Korea, Republic of)

    2005-02-15

    Water was used as a polar modifier and a μ-porasil column as a saturator column. The μ-porasil column was inserted between the pump outlet and the injection valve. During the passage of the supercritical fluid mobile phase through the silica column, a polar modifier (water) can be dissolved in the pressurized supercritical fluid. Dimethylpolysiloxane polymer has been known as more polar polymer than polystyrene polymer. Dimethylpolysiloxane polymer has never been separated using water modified mobile phase. In this paper, using a μ-porasil column as a saturator column, excellent supercritical fluid chromatograms of dimethylpolysiloxane oligomers were obtained. The use of compressed (dense) gases and supercritical fluids as chromatographic mobile phases in conjunction with liquid chromatographic (LC)-type packed columns was first reported by Klesper et al. in 1962. During its relatively short history, supercritical fluid chromatography (SFC) has become an attractive alternative to GC and LC in certain industrially important applications. SFC gives the advantage of high efficiency and allows the analysis of nonvolatile or thermally labile mixtures.

  4. Supercritical Fluid Chromatographic Separation of Dimethylpolysiloxane Polymer

    International Nuclear Information System (INIS)

    Pyo, Dong Jin; Lim, Chang Hyun

    2005-01-01

    Water was used as a polar modifier and a μ-porasil column as a saturator column. The μ-porasil column was inserted between the pump outlet and the injection valve. During the passage of the supercritical fluid mobile phase through the silica column, a polar modifier (water) can be dissolved in the pressurized supercritical fluid. Dimethylpolysiloxane polymer has been known as more polar polymer than polystyrene polymer. Dimethylpolysiloxane polymer has never been separated using water modified mobile phase. In this paper, using a μ-porasil column as a saturator column, excellent supercritical fluid chromatograms of dimethylpolysiloxane oligomers were obtained. The use of compressed (dense) gases and supercritical fluids as chromatographic mobile phases in conjunction with liquid chromatographic (LC)-type packed columns was first reported by Klesper et al. in 1962. During its relatively short history, supercritical fluid chromatography (SFC) has become an attractive alternative to GC and LC in certain industrially important applications. SFC gives the advantage of high efficiency and allows the analysis of nonvolatile or thermally labile mixtures

  5. Chromatographic Separation of Vitamin E Enantiomers

    Directory of Open Access Journals (Sweden)

    Ju-Yen Fu

    2017-02-01

    Full Text Available Vitamin E is recognized as an essential vitamin since its discovery in 1922. Most vegetable oils contain a mixture of tocopherols and tocotrienols in the vitamin E composition. Structurally, tocopherols and tocotrienols share a similar chromanol ring and a side chain at the C-2 position. Owing to the three chiral centers in tocopherols, they can appear as eight different stereoisomers. Plant sources of tocopherol are naturally occurring in the form of RRR while synthetic tocopherols are usually in the form of all-racemic mixture. Similarly, with only one chiral center, natural tocotrienols occur as the R-isoform. In this review, we aim to discuss a few chromatographic methods that had been used to separate the stereoisomers of tocopherols and tocotrienols. These methods include high performance liquid chromatography, gas chromatography and combination of both. The review will focus on method development including selection of chiral columns, detection method and choice of elution solvent in the context of separation efficiency, resolution and chiral purity. The applications for separation of enantiomers in vitamin E will also be discussed especially in terms of the distinctive biological potency among the stereoisoforms.

  6. Single-column extraction chromatographic separation of U, Pu, Np and Am

    Energy Technology Data Exchange (ETDEWEB)

    Morgenstern, A.; Apostolidis, C.; Carlos-Marquez, R.; Mayer, K.; Molinet, R. [Commission of the European Communities, Karlsruhe (Germany). European Inst. for Transuranium Elements

    2002-07-01

    A rapid, single-column extraction chromatographic method using commercially available UTEVA resin has been developed for the separation of uranium, plutonium, neptunium and americium. The method yields recoveries superior to 90% and allows direct loading of separated fractions on filaments for subsequent analysis by thermal ionization mass spectrometry. The use of reagents compatible with robotized equipment allows automation of the separation process for routine analysis of nuclear materials. The redox reactions between plutonium, neptunium and hydrogen peroxide involved in the separation process were studied by UV/Vis/NIR absorption spectroscopy. (orig.)

  7. Nanocapillaries for Open Tubular Chromatographic Separations of Proteins in Femtoliter to Picoliter Samples

    Science.gov (United States)

    Wang, Xiayan; Cheng, Chang; Wang, Shili; Zhao, Meiping; Dasgupta, Purnendu K.; Liu, Shaorong

    2009-01-01

    We have recently examined the potential of bare nanocapillaries for free solution DNA separations and demonstrated efficiencies exceeding 106 theoretical plates/m. In the present work, we demonstrate the use of bare and hydroxypropylcellulose (HPC) coated open tubular nanocapillaries for protein separations. Using 1.5 μm inner diameter (i.d.) capillary columns, hydrodynamically injecting femto to picoliter (fL-pL) volumes of fluorescent or fluorescent dye labeled protein samples, utilizing a pneumatically pressurized chamber containing 1.0 mM sodium tetraborate solution eluent (typ. 200 psi) as the pump and performing on-column detection using a simple laser-induced fluorescence detector, we demonstrate efficiencies of close to a million theoretical plates/m while generating single digit μL volumes of waste for a complete chromatographic run. We achieve baseline resolution for a protein mixture consisting of transferrin, α-lactalbumin, insulin, and α -2-macroglobulin. PMID:19663450

  8. Liquid chromatographic separation of terpenoid pigments in foods and food products.

    Science.gov (United States)

    Cserháti, T; Forgács, E

    2001-11-30

    The newest achievements in the use of various liquid chromatographic techniques such as adsorption and reversed-phase thin-layer chromatography and HPLC employed for the separation and quantitative determination of terpenoid-based color substances in foods and food products are reviewed. The techniques applied for the analysis of individual pigments and pigments classes are surveyed and critically evaluated. Future trends in the separation and identification of pigments in foods and food products are delineated.

  9. Adsorption chromatographic separation of radioiodine-labelled compounds using binary eluents

    International Nuclear Information System (INIS)

    Toth, G.

    1980-01-01

    An adsorption chromatographic method using Sephadex LH-20 dextran gel as adsorbent and water-organic solvent binary eluents was developed for the systematic separation of low molecular weight radioiodine-labelled substances like iodothyronines, iodobenzoic acids and iodotyrosine methyl ester derivatives of prostaglandins, steroids etc. The adsorbed iodine compounds were separated by water-organic solvent mixture, and the order of the compounds is in accordance with the increasing number of iodine substituents per molecule. A method is reported which enables the calculation of the eluent strength of the water-organic solvent eluents. (author)

  10. Chromatographic separation of alkaline phosphatase from dental enamel

    DEFF Research Database (Denmark)

    Moe, D; Kirkeby, S; Salling, E

    1989-01-01

    Alkaline phosphatase (AP) was prepared from partly mineralized bovine enamel by extraction in phosphate buffer, centrifugation and various chromatographic techniques. Chromatofocusing showed that the enamel enzyme possessed five isoelectric points at the acid pH level ranging from pH 5.7 to pH 4.......4. Three enzyme peaks were eluted using low pressure chromatography with a Bio-gel column. With a HPLC gel filtration column the separation of the enamel extract resulted in only one peak with AP activity. The fractions of this peak were used to produce an antibody against bovine AP....

  11. Chromatographic separation and spectro-analytical characterization of a natural African mineral dye

    Directory of Open Access Journals (Sweden)

    G.B. Adebayo

    2007-08-01

    Full Text Available Chromatographic fractionation and spectroscopic characterization of a natural African mineral dye have been carried out. The chromatographic separation of the dyes made use of column and thin layer chromatographic techniques. Some physicochemical properties of the dye including solubility in polar and non-polar solvents, pH, ash and organic contents were determined. The spectro-analytical techniques used for characterization included energy dispersive X-ray fluorescence (EDXRF, X-ray diffractometry (XRD, Optical microscopy, infrared (IR and UV-VIS spectroscopy. Four different fractions having colours yellow, grey, orange and purple were obtained from the chromatographic separation. All the fractions were found to contain aromatic nucleus based on IR and UV-VIS spectroscopic data. Other functional groups detected are Ar-NH2, -CONH2, C=C, C-C and metal-carbon chelate rings. The presence of aromatic amine in the dye provides strong evidence for its use as hair dye. The dye was found to be soluble in both aqueous and non-aqueous solvents. The pH of the dye's aqueous solution was found to be 8.6, and the ash and organic content of the raw dye were 49 % and 51 % respectively. The XRF revealed that the dye contains twenty elements with concentrations ranging from major to ultra-trace levels. The XRD also showed that the sample contains about forty-six mineral phases which include both inorganic and organic components. The maximum absorption wavelength (λmax in UV-VIS of the aqueous solution was found to be 464 nm. The optical microscopic investigation gave indication that the dyes are likely to be of the marine origin.

  12. Separation and determination of high-carbon alcohols using method of column chromatographic and gas-chromatographic analysis

    International Nuclear Information System (INIS)

    Kang Zhongrong; Li Biping; Zeng Yongchang

    1988-01-01

    This paper describes the separation and determination of high-carbon alcohols from amine extractant by using the method of column chromatography of aluminium oxide and gas-chromatographic analysis. The total conent of high-carbon alcohols is determined by the method of column chromatography, while the components of the high-carbon alcohols and their relative contents are determined by the method of gas-chromatography. A simple reliable and practical method is provided for the analysis of high-carbon alcohol from the amine extractant in this paper

  13. Use of laminar chromatographic methods for determination of separation conditions in column extraction chromatography

    International Nuclear Information System (INIS)

    Ghersini, G.; Cerrai, E.

    1978-01-01

    Possibilities of using laminar chromatographic methods (paper and thin-layer chromatography) to determine optimal separation conditions in column extraction chromatography are analysed. Most of the given laminar methods are presented as Rf-spectra, i.e. as dependences of Rf found experimentally on eluating solution component concentration. Interrelation between Rf and distribution coefficients of corresponding liquid extraction systems and retention volumes of chromatographic columns is considered. Literature data on extraction paper and thin-layer chromatography of elements with various immovable phases are presented

  14. Liquid chromatographic separation of zalcitabine and its stereoisomers.

    Science.gov (United States)

    Scypinski, S; Ross, A J

    1994-10-01

    A liquid chromatographic method capable of separating and quantitating the stereoisomers of zalcitabine has been developed and validated. The separation was achieved with an Astec Cyclobond I--RSP column and a mobile phase of 0.25% triethylamine in water adjusted to a pH of 6.5 with glacial acetic acid. All enantiomers were found to exhibit a linear response in the range of 0.1-10% in the presence of 100% zalcitabine. Precision of analysis was found to be less than 1.5% at a level of 1% relative to zalcitabine. The limit of detection for two of the three enantiomeric impurities was determined to be 0.05% relative to zalcitabine. The detection limit for the third was found to be 0.1%. This method was successfully applied to the analysis of reference standards and several production scale batches. All of these materials were found to be stereochemically pure to a level of 99.8% or better.

  15. Large scale gas chromatographic demonstration system for hydrogen isotope separation

    International Nuclear Information System (INIS)

    Cheh, C.H.

    1988-01-01

    A large scale demonstration system was designed for a throughput of 3 mol/day equimolar mixture of H,D, and T. The demonstration system was assembled and an experimental program carried out. This project was funded by Kernforschungszentrum Karlsruhe, Canadian Fusion Fuel Technology Projects and Ontario Hydro Research Division. Several major design innovations were successfully implemented in the demonstration system and are discussed in detail. Many experiments were carried out in the demonstration system to study the performance of the system to separate hydrogen isotopes at high throughput. Various temperature programming schemes were tested, heart-cutting operation was evaluated, and very large (up to 138 NL/injection) samples were separated in the system. The results of the experiments showed that the specially designed column performed well as a chromatographic column and good separation could be achieved even when a 138 NL sample was injected

  16. Subsurface migration of petroleum hydrocarbons: A case study of immiscible migration and chromatographic separation

    International Nuclear Information System (INIS)

    Dawson, H.E.

    1991-01-01

    The subsurface distribution of a leaked crude oil illustrates the combined influence of both the chemical and physical properties of soil and free product on the migration of petroleum hydrocarbons. Immiscible phase behavior was observed, as well as chromatographic-like separation of the lighter constituents of the crude oil from the heavier constituents. After downward migration through approximately 50 ft of unsaturated, heterogeneous alluvial sediments, the crude oil formed a horizontal plume on top of a perched, saturated zone. Immiscible phase trapping is evident from the occurrence of very high concentration of hydrocarbons in both the vertical and horizontal plumes. Samples taken from the vertical zone of contamination indicate a transition from heavier hydrocarbons near the surface to lighter hydrocarbons at depth. This phenomenon is attributed to chromatographic-like separation of the heavier hydrocarbons by the soil, possibly due to preferential solubility of the lighter hydrocarbons in percolating ran water

  17. The employment of cellulose pressure columns for the chromatographic separation of radioactive nuclides

    International Nuclear Information System (INIS)

    Meier, H.; Zimmerhackl, E.; Unger, E.; Zeitler, G.; Albrecht, W.; Boesche, D.; Hecker, W.; Menge, P.

    1975-01-01

    A study was made of the separation properties of cellulose pressure columns operating at a slight over-pressure of around 1 atmosphere, with respect to the length of the column packing, the flow rate, and the load. The optimal separation stage heights of the columns are situated at H=0.16 mm. Since as a consequence of the favorable separation stage heights observed at column lengths of 3 to 7 cm, separation stage numbers of 200 to 400 are attained, and hence it is possible to attain separations within several minutes with flow rates of 1 ml/min. The choice of the mobile phase is made easier by the fact that paper chromatographic Rsub(f)-values can be transferred to the cellulose pressure column with the aid of a transfer function. (author)

  18. Multiple-channel ultra-violet absorbance detector for two-dimensional chromatographic separations.

    Science.gov (United States)

    Lynch, Kyle B; Yang, Yu; Ren, Jiangtao; Liu, Shaorong

    2018-05-01

    In recent years, much research has gone into developing online comprehensive two-dimensional liquid chromatographic systems allowing for high peak capacities in comparable separation times to that of one-dimensional liquid chromatographic systems. However, the speed requirements in the second dimension (2nd-D) still remain one challenge for complex biological samples due to the current configuration of two column/two detector systems. Utilization of multiple 2nd-D columns can mitigate this challenge. To adapt this approach, we need a multiple channel detector. Here we develop a versatile multichannel ultraviolet (UV) light absorbance detector that is capable of simultaneously monitoring separations in 12 columns. The detector consists of a deuterium lighthouse, a flow cell assembly (a 13-channel flow cell fitted with a 13-photodiode-detection system), and a data acquisition and monitoring terminal. Through the use of a custom high optical quality furcated fiber to improve light transmission, precise machining of a flow cell to reduce background stray light through precision alignment, and sensitive electronic circuitry to reduce electronic noise through an active low pass filter, the background noise level is measured in the tens of µAU. We obtain a linear dynamic range of close to three orders of magnitude. Compared to a commercialized multichannel UV light absorbance detector like the Waters 2488 UV/Vis, our device provides an increase in channel detection while residing within the same noise region and linear range. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Separative analyses of a chromatographic column packed with a core-shell adsorbent for lithium isotope separation

    International Nuclear Information System (INIS)

    Sugiyama, T.; Sugura, K.; Enokida, Y.; Yamamoto, I.

    2015-01-01

    Lithium-6 is used as a blanket material for sufficient tritium production in DT fueled fusion reactors. A core-shell type adsorbent was proposed for lithium isotope separation by chromatography. The mass transfer model in a chromatographic column consisted of 4 steps, such as convection and dispersion in the column, transfer through liquid films, intra-particle diffusion and and adsorption or desorption at the local adsorption sites. A model was developed and concentration profiles and time variation in the column were numerically simulated. It became clear that core-shell type adsorbents with thin porous shell were saturated rapidly relatively to fully porous one and established a sharp edge of adsorption band. This is very important feature because lithium isotope separation requires long-distance development of adsorption band. The values of HETP (Height Equivalent of a Theoretical Plate) for core-shell adsorbent packed column were estimated by statistical moments of the step response curve. The value of HETP decreased with the thickness of the porous shell. A core-shell type adsorbent is, then, useful for lithium isotope separation. (authors)

  20. Chromatographic separation of radioactive noble gases from xenon

    Science.gov (United States)

    Akerib, D. S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bramante, R.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Coffey, T.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Pech, K.; Phelps, P.; Reichhart, L.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Yazdani, K.; Young, S. K.; Zhang, C.

    2018-01-01

    The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes 85Kr and 39Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search experiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

  1. Column chromatographic separation of Y3+ from Sr2+ by polymeric ionizable crown ether resins

    International Nuclear Information System (INIS)

    Wood, D.J.; Elshani, S.; Wai, C.M.; Bartsch, R.A.; Huntley, M.; Hartenstein, S.

    1993-01-01

    Condensation polymers containing subunits of crown ether carboxylic acid monomers are effective stationary phases for the chromatographic separation of Y 3+ and Sr 2+ . The pH range and metal loading capacities for the resins have been determined under equilibrium conditions. The resin can be regenerated for repeated use without losing its separation capability. Altering the molecular structure of the monomer (sym-dibenzo-16-crown-5-oxyacetic acid) by an alkyl substitution on the macrocyclic cavity decreases the loading capacity of the resin

  2. Modified molecular sieves: stationary phase for the gas chromatographic separation of hydrogen isotopes

    International Nuclear Information System (INIS)

    Pushpa, K.K.; Annaji Rao, K.; Iyer, R.M.

    1993-01-01

    Gas chromatographic separation of hydrogen isotopes on different molecular sieves at liquid nitrogen temperature has been investigated. Normal molecular sieves 5A, 13X and AW500 are not satisfactory for the purpose both in the partially dehydrated as well as totally dehydrated state. Molecular sieve 4A in partially dehydrated state separated H 2 and D 2 while H 2 and HD are not well resolved. Iron exchanged or coated molecular sieves 4A, 5A, 13X and AW500 in the partially dehydrated state separated the isotopic mixtures H 2 , HD, D 2 and H 2 , HT, T 2 . The resolution varied depending on the amount of iron content and the residual moisture in the molecular sieves. Good separations were obtained on 15% Fe coated molecular sieve 5A and 5% Fe coated molecular sieve 4A. (author). 18 refs., 6 figs., 3 tabs

  3. Chemometric approach for development, optimization, and validation of different chromatographic methods for separation of opium alkaloids.

    Science.gov (United States)

    Acevska, J; Stefkov, G; Petkovska, R; Kulevanova, S; Dimitrovska, A

    2012-05-01

    The excessive and continuously growing interest in the simultaneous determination of poppy alkaloids imposes the development and optimization of convenient high-throughput methods for the assessment of the qualitative and quantitative profile of alkaloids in poppy straw. Systematic optimization of two chromatographic methods (gas chromatography (GC)/flame ionization detector (FID)/mass spectrometry (MS) and reversed-phase (RP)-high-performance liquid chromatography (HPLC)/diode array detector (DAD)) for the separation of alkaloids from Papaver somniferum L. (Papaveraceae) was carried out. The effects of various conditions on the predefined chromatographic descriptors were investigated using chemometrics. A full factorial linear design of experiments for determining the relationship between chromatographic conditions and the retention behavior of the analytes was used. Central composite circumscribed design was utilized for the final method optimization. By conducting the optimization of the methods in very rational manner, a great deal of excessive and unproductive laboratory research work was avoided. The developed chromatographic methods were validated and compared in line with the resolving power, sensitivity, accuracy, speed, cost, ecological aspects, and compatibility with the poppy straw extraction procedure. The separation of the opium alkaloids using the GC/FID/MS method was achieved within 10 min, avoiding any derivatization step. This method has a stronger resolving power, shorter analysis time, better cost/effectiveness factor than the RP-HPLC/DAD method and is in line with the "green trend" of the analysis. The RP-HPLC/DAD method on the other hand displayed better sensitivity for all tested alkaloids. The proposed methods provide both fast screening and an accurate content assessment of the six alkaloids in the poppy samples obtained from the selection program of Papaver strains.

  4. Investigating the Effect of Column Geometry on Separation Efficiency using 3D Printed Liquid Chromatographic Columns Containing Polymer Monolithic Phases.

    Science.gov (United States)

    Gupta, Vipul; Beirne, Stephen; Nesterenko, Pavel N; Paull, Brett

    2018-01-16

    Effect of column geometry on the liquid chromatographic separations using 3D printed liquid chromatographic columns with in-column polymerized monoliths has been studied. Three different liquid chromatographic columns were designed and 3D printed in titanium as 2D serpentine, 3D spiral, and 3D serpentine columns, of equal length and i.d. Successful in-column thermal polymerization of mechanically stable poly(BuMA-co-EDMA) monoliths was achieved within each design without any significant structural differences between phases. Van Deemter plots indicated higher efficiencies for the 3D serpentine chromatographic columns with higher aspect ratio turns at higher linear velocities and smaller analysis times as compared to their counterpart columns with lower aspect ratio turns. Computational fluid dynamic simulations of a basic monolithic structure indicated 44%, 90%, 100%, and 118% higher flow through narrow channels in the curved monolithic configuration as compared to the straight monolithic configuration at linear velocities of 1, 2.5, 5, and 10 mm s -1 , respectively. Isocratic RPLC separations with the 3D serpentine column resulted in an average 23% and 245% (8 solutes) increase in the number of theoretical plates as compared to the 3D spiral and 2D serpentine columns, respectively. Gradient RPLC separations with the 3D serpentine column resulted in an average 15% and 82% (8 solutes) increase in the peak capacity as compared to the 3D spiral and 2D serpentine columns, respectively. Use of the 3D serpentine column at a higher flow rate, as compared to the 3D spiral column, provided a 58% reduction in the analysis time and 74% increase in the peak capacity for the isocratic separations of the small molecules and the gradient separations of proteins, respectively.

  5. The separation of sup(99m)Tc from 99Mo through an aluminium oxide chromatographic columm

    International Nuclear Information System (INIS)

    Imoto, S.T.

    1980-01-01

    The separation of sup(99m)Tc from 99 Mo using the chromatographic method is studied. Alumina is used as adsorbent. The pH values for adsorption of carrier-free 99 Mo on columns filled with ordinary alumina and with that thermically treated at 1000 0 C for five hours, and the separation conditions of sup(99m)Tc using physiologic solution as eluent are determined. The sup(99m)Tc separation yields of both columns are compared and the quality of the products obtained by successive elutions for 10 days is analyzed. (Author) [pt

  6. Chromatographic separation of low-temperature tar. Part III

    Energy Technology Data Exchange (ETDEWEB)

    Terres, E; Gebert, F; Huelsemann, H; Petereit, H; Toepsch, H; Ruppert, W

    1955-01-01

    Experiments with crude phenolic mixtures in benzene-MeOH over an alumina chromatographic column are reported. The most effective separation into crude fractions was obtained from a petroleum-ether solution with benzene and benzene-MeOH elution. These fractions are analyzed by paper chromatography. R/sub f/ values for 29 phenols and benzoic acid from water-saturated AmOH are given. Folin-Denis reagent and ultraviolet absorption is used for identification of the phenolic compounds. R/sub f/ values for monohydroxy compounds are larger than 0.9, dihydroxy 0.80 to 0.9, trihydroxy 0.6, hydroxytoluic acids 0.39 to 0.56. R/sub f/ values of Na and K salts are different from those of the free phenols. Tests in aqueous solution near 0/sup 0/ gave important results. R/sub f/ values of the less polar materials decrease and less material is lost through evaporation, smaller and sharper spots are obtained and liquids move at a more even rate. A series of isomeric alkyl phenols is reported; ortho alkyl groups decrease the migration rate most effectively.

  7. Green Chromatographic Separation of Coumarin and Vanillins Using Subcritical Water as the Mobile Phase.

    Science.gov (United States)

    Kayan, Berkant; Akay, Sema; Yang, Yu

    2016-08-01

    Pure water was used as the eluent for separation of coumarin, vanillin and ethyl vanillin at temperatures ranging from 100 to 200°C using a homemade subcritical water chromatography (SBWC) system. Chromatographic separations were performed on five commercial columns including XTerra MS C18, XBridge C18, Zorbax RRHD Eclipse Plus, Zorbax SB-Phenyl and Zorbax SB-C18 columns. The retention time of all three solutes decreased with increasing water temperature. The shortest retention time among all acceptable separations, less than 4 min, was achieved on the Zorbax SB-C18 column at 200°C. While separations on the XTerra MS C18 column resulted in fronting peaks and a degradation peak from ethyl vanillin on the Zorbax RRHD Eclipse Plus column was observed, all three other columns yielded reasonable separations under SBWC conditions. In addition to separation of the standard test mixture, separation of coumarin contained in a skincare cream sample was also carried out using SBWC. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Chromatographic separation of fructose from date syrup.

    Science.gov (United States)

    Al Eid, Salah M

    2006-01-01

    The objective of this study is to provide a process for separating fructose from a mixture of sugars containing essentially fructose and glucose, obtained from date palm fruits. The extraction procedure of date syrup from fresh dates gave a yield of 86.5% solids after vacuum drying. A process for separating fructose from an aqueous solution of date syrup involved adding the date syrup solutions (20, 30 and 40% by weight) to a chromatographic column filled with Dowex polystyrene strong cation exchange gel matrix resin Ca2 + and divinylbenzene, a functional group, sulfonic acid, particle size 320 microm, with a flow rate of 0.025 and 0.05 bed volume/min, under 30 and 70 degrees C column temperature. After the date sugar solution batch, a calculated quantity of water was added to the column. Glucose was retained by the resin more weakly than fructose and proceeded faster into the water batch flowing ahead. Three fractions were collected: a glucose-rich fraction, a return fraction, and a fructose-rich fraction. The return fraction is based on when the peaks of fructose and glucose were reached, which could be determined by means of an analyzer (polarimeter) based on the property of glucose and fructose solutions to turn the polarization level of polarized light. A high yield of fructose is obtained at 70 degrees C column temperature with a flow rate of 0.025 bed volume/min and date syrup solution containing 40% sugar concentration. The low recovery by weight obtained using date syrup solutions having a sugar concentration of 20 and 30%, encourages the use of a concentration of 40%. However, with the 40% date syrup supply the average concentrations of glucose and fructose in the return fractions were more than 40%, which can be used for diluting the thick date syrup solution extracted from dates.

  9. Incorporation of metal-organic framework HKUST-1 into porous polymer monolithic capillary columns to enhance the chromatographic separation of small molecules.

    Science.gov (United States)

    Yang, Shengchao; Ye, Fanggui; Lv, Qinghui; Zhang, Cong; Shen, Shufen; Zhao, Shulin

    2014-09-19

    Metal-organic framework (MOF) HKUST-1 nanoparticles have been incorporated into poly(glycidyl methacrylate-co-ethylene dimethacrylate) (HKUST-1-poly(GMA-co-EDMA)) monoliths to afford stationary phases with enhanced chromatographic performance of small molecules in the reversed phase capillary liquid chromatography. The effect of HKUST-1 nanoparticles in the polymerization mixture on the performance of the monolithic column was explored in detail. While the bare poly(GMA-co-EDMA) monolith exhibited poor resolution (RsHKUST-1 nanoparticles to the polymerization mixture provide high increased resolution (Rs≥1.3) and high efficiency ranged from 16,300 to 44,300plates/m. Chromatographic performance of HKUST-1-poly(GMA-co-EDMA) monolith was demonstrated by separation of various analytes including polycyclic aromatic hydrocarbons, ethylbenzene and styrene, phenols and aromatic acids using a binary polar mobile phase (CH3CN/H2O). The HKUST-1-poly(GMA-co-EDMA) monolith displayed enhanced hydrophobic and π-π interaction characteristics in the reversed phase separation of test analytes compared to the bare poly(GMA-co-EDMA) monolith. The experiment results showed that HKUST-1-poly(GMA-co-EDMA) monoliths are an alternative to enhance the chromatographic separation of small molecules. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Chromatographic separation of metal ions by means of paper treated with trioctyl - phosphate, Annex 7

    Energy Technology Data Exchange (ETDEWEB)

    Cvjeticanin, N M; Cvoric, J D; Obrenovic-Paligoric, I D [Institute of Nuclear Sciences Boris Kidric, Laboratorija za visoku aktivnost, Vinca, Beograd (Serbia and Montenegro)

    1963-12-15

    This chromatographic behaviour of uranium, thorium and some other metal ions and long-lived fission products was investigated on paper treated with trioctyl-phosphate. Hydrochloric, nitric, sulphuric and perchloric acids in concentrations of 0.1-10 N were used as the elution agents. The R{sub f} values of the ions investigated, which show the possibility of the inter separation of some cations, are given as a function of the concentration of acids (author)

  11. Chromatographic separation of low-temperature tar. Part II

    Energy Technology Data Exchange (ETDEWEB)

    Terres, E; Gebert, F; Huelsemann, H; Petereit, H; Toepsch, H; Ruppert, W

    1955-01-01

    Chromatographic methods and apparatus are discussed. The Folin-Denis reagent (Na tungstate molybdate in H/sub 3/PO/sub 4/) is used for developing paper chromatograms of phenol mixtures. Other reagents are given.

  12. Conceptual design of hydrogen isotopes chromatographic separation system with super large capacity

    International Nuclear Information System (INIS)

    Xie Bo; Weng Kuiping; Liu Yunnu; Hou Jianping

    2012-01-01

    A super large capacity hydrogen isotopes separation system, including total plan, unit (including making and purification of gas, three-grade chromatographic columns, gas loop and auto-control, and carrier recovery) and experimental scheme, had been designed on the basis of a series of hydrogen-deuterium experiments by temperature programmed de- sorption. The characteristic of the system was that desorption kinetic parameters could be directly calculated from the hydrogen isotope separation desorption spectra information. In other words, the complicated dynamic process of separation could be described by the desorption rate equation, shape parameter and desorption activation energy calculation on the condition of the experimental data and appropriate assumptions (equilibrium and adsorption, uniform surface). In previous work, an experimental series of operation to verify the successive enrichment of D 2 from a H 2 -D 2 mixture, the production of the deuterium from natural hydrogen and the recovery of tritium such as from the nuclear heavy-water were carried out using MS5A at 77 K. This work was only conceptual design, so it was necessary to identify the availability of super large capacity system by experiment. (authors)

  13. Facile room-temperature solution-phase synthesis of a spherical covalent organic framework for high-resolution chromatographic separation.

    Science.gov (United States)

    Yang, Cheng-Xiong; Liu, Chang; Cao, Yi-Meng; Yan, Xiu-Ping

    2015-08-07

    A simple and facile room-temperature solution-phase synthesis was developed to fabricate a spherical covalent organic framework with large surface area, good solvent stability and high thermostability for high-resolution chromatographic separation of diverse important industrial analytes including alkanes, cyclohexane and benzene, α-pinene and β-pinene, and alcohols with high column efficiency and good precision.

  14. Evaluation of chromatographic columns packed with semi- and fully porous particles for benzimidazoles separation.

    Science.gov (United States)

    Gonzalo-Lumbreras, Raquel; Sanz-Landaluze, Jon; Cámara, Carmen

    2015-07-01

    The behavior of 15 benzimidazoles, including their main metabolites, using several C18 columns with standard or narrow-bore diameters and different particle size and type were evaluated. These commercial columns were selected because their differences could affect separation of benzimidazoles, and so they can be used as alternative columns. A simple screening method for the analysis of benzimidazole residues and their main metabolites was developed. First, the separation of benzimidazoles was optimized using a Kinetex C18 column; later, analytical performances of other columns using the above optimized conditions were compared and then individually re-optimized. Critical pairs resolution, analysis run time, column type and characteristics, and selectivity were considered for chromatographic columns comparison. Kinetex XB was selected because it provides the shortest analysis time and the best resolution of critical pairs. Using this column, the separation conditions were re-optimized using a factorial design. Separations obtained with the different columns tested can be applied to the analysis of specific benzimidazoles residues or other applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A Small-Scale Low-Cost Gas Chromatograph

    Science.gov (United States)

    Gros, Natasa; Vrtacnik, Margareta

    2005-01-01

    The design and application of a small-scale portable gas chromatograph for learning of the basic concepts of chromatography is described. The apparatus consists of two basic separable units, which includes a chromatographic unit and an electronic unit.

  16. High performance liquid chromatographic separation of thirteen drugs collected in Chinese Pharmacopoeia 2010(Ch.P2010 on cellulose ramification chiral stationary phase

    Directory of Open Access Journals (Sweden)

    Ying Zhou

    2012-02-01

    Full Text Available The enantiomers separation of thirteen drugs collected in Ch.P2010 was performed on chiral stationary phase of cellulose ramification (chiralpak OD and chiralpak OJ by high performance liquid chromatographic (HPLC methods, which included ibuprofen (C1, ketoprofen (C2, nitrendipine (C3, nimodipine (C4, felodipine (C5, omeprazole (C6, praziquantel (C7, propranolol hydrochloride (C8, atenolol (C9, sulpiride (C10, clenbuterol hydrochloride (C11, verapamil hydrochloride (C12, and chlorphenamine maleate (C13. The mobile phase consisted of isopropanol and n-hexane. The detection wavelength was set at 254 nm and the flow rate was 0.7 mL/min. The enantiomers separation of these thirteen racemates on chiralpak OD column and chiralpak OJ column was studied, while the effects of proportion of organic additives, alcohol displacer and temperature on the separation were studied. And the mechanism of some of racemates was discussed. The results indicated that thirteen chiral drugs could be separated on chiral stationary phase of cellulose ramification in normal phase chromatographic system. The chromatographic retention and resolution of enantiomers could be adjusted by factors including column temperature and the concentration of alcohol displacer and organic alkaline modifier in mobile phase. It was shown that the resolution was improved with reducing concentration of alcohol displacer. When concentration of organic alkaline modifier was 0.2% (v/v, the resolution and the peak shape were fairly good. Most racemates mentioned above had better resolution at column temperature of 25 °C. When racemates were separated, the temperature should be kept so as to obtain stable separation results. Keywords: HPLC, Chiral stationary phase, Optical enantiomers, Cellulose ramification

  17. Ten years of experience in extraction chromatographic processes for the recovery, separation and purification of actinides elements

    International Nuclear Information System (INIS)

    Madic, C.; Bourges, J.; Koehly, G.

    1984-06-01

    Ten years ago the extraction chromatographic technique was developed for preparative purposes and is now applied for all chemicals separations needed for the production of actinides isotopes. That technique appears to be simple and flexible. It can be used for the production of microgram to kilogram amounts of actinide isotopes. This paper focuses on the experience gained and describes some peculiar production of actinide isotopes solved by using extraction chromatographic technique. After a review of extracting molecules and equipment, treatment of irradiated targets (preparation of Pu 238 and removal of neptunium, production of Am 243 and Cm 244), recovery of actinides from alpha aqueous wastes (preparation of Am 241) and recovery of decay products from aged actinide stocks (recovery of Am 241 from Pu stocks, of U 234 from Pu 238 stocks) are described

  18. Ion chromatographic determination of Di-n-butyl phosphate in degraded organic solvent

    International Nuclear Information System (INIS)

    Velavendan, P.; Pandey, N.K.; Kamachi Mudali, U.; Natarajan, R.

    2011-01-01

    In the present work a method for the determination of Di-n-butyl phosphate in organic streams using Ion Chromatography technique is developed and described here. The method involves the separation of Di-n-butyl phosphate (DBP) from 30% TBP-NPH (Tri-n-butylphosphate diluted in Normal Paraffin Hydrocarbon) and uranium/nitric acid matrix by an extraction of DBP in alkaline medium and subsequent ion-exchange separation in ion chromatography column followed by suppressed conductivity detection. Direct determination of DBP in lean/loaded organic solvent will lead to in accurate determination of DBP due to organic interference. DBP is quantified to lower limit of 1 ppm with 3% RSD. The results obtained with ion chromatographic technique are compared with those obtained by standard gas chromatographic technique. The developed method is much faster and total analysis can be completed within two hours. (author)

  19. Extraction chromatographic separation of Sr, Pu and Am in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Sidhu, Rajdeep

    2004-04-01

    An accurate determination of radionuclides from various sources in the environment is essential for assessment of the potential hazards and suitable countermeasures both in case of an authorised release, accidents and routine surveillance. Due to the short range of alpha and beta radiation, the accurate determination of pure alpha and beta emitters must always include radiochemical separations to separate the analytes from the matrix and from other interfering stable and radioactive nuclides. Hence, the procedures used for their determination are usually tedious and involve several preconcentration and separation steps. This work deals with the determination of {sup 90}Sr, {sup 241}Am, {sup 238}Pu, {sup 239,240}Pu and {sup 244}Cm, whic some of the most important artificial radionuclides. Due to either absence or low yield of gamma radiation, a secure determination of low concentrations of all these nuclides requires a dedicated chemistry. Selective extraction chromatographic resins (TRU- and Sr-Resin) have been utilised to develop new procedures for the analyses of Pu, Am and Cm isotopes in seawater and both these and {sup 90}Sr in soil, sediment, urine and low-level liquid radioactive effluents. The proposed method for the analyses of Pu and Am in seawater offers a quick and secure mode for the determination of these radionuclides in marine waters. Combined pre-concentration of actinides and strontium (oxalate or phosphate precipitation) followed by dual column separation on TRU- and Sr-Resin significantly reduces the through put time and costs compared to traditional ion exchange and precipitation methods. The greatest gain in productivity and environmental friendliness is achieved in Sr separations using Sr-Resin instead of precipitations involving fuming nitric acid and oxalate, hydroxide, chromate and carbonate precipitations. (author)

  20. Total cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation

    International Nuclear Information System (INIS)

    Takatsu, Akiko; Nishi, Sueo

    1988-01-01

    We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid chromatographic separation. After adding [3,4- 13 C] cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. High-performance liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement by electron-impact mass spectrometry with use of a direct-insertion device. To evaluate the specificity and the accuracy of this method, we also studied the conventional IDMS method, which involves converting cholesterol to the trimethylsilyl ether and assay by gas chromatography-mass spectrometry with use of a capillary column. The coefficient of variation for the HPLC method was a little larger than for the conventional method, but mean values by each method agreed within 1% for all sera tested. (author)

  1. [Development of an automatic vacuum liquid chromatographic device and its application in the separation of the components from Schisandra chinensis (Turz) Baill].

    Science.gov (United States)

    Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei

    2015-08-01

    In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.

  2. Effects of chromatographic fractions of Euphorbia hirta on the rat ...

    African Journals Online (AJOL)

    The effects of the chromatographic fractions of Euphorbia hirta Linn on the serum biochemical parameters in rats were investigated. The ethanolic extract of this plant was subjected to chromatographic separation using the vacuum liquid chromatographic technique, a modified form of classical column chromatography.

  3. Characterization of crude oils and petroleum products: (I Elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products

    Directory of Open Access Journals (Sweden)

    E.O. Odebunmi

    2002-12-01

    Full Text Available Some physical and chemical properties of samples of light, medium and heavy Nigerian crude oils and petroleum products including gasoline, kerosene and engine oil have been measured and are reported in this paper. The crude oils and petroleum products have also been characterized by fractional distillation and elution liquid chromatography. The fractions obtained from elution liquid chromatography were analyzed using gas chromatography (GC. The GC fractions were identified by comparing the retention time of peaks in the unknown samples with those of components of calibration standard mixtures. The importance of the physico-chemical properties and the significance of the fractional distillation and chromatographic separation methods to industrial process operations have been discussed.

  4. New chromatographic method for separating Omeprazole from its degradation components and the quantitatively determining it in its pharmaceutical products

    International Nuclear Information System (INIS)

    Touma, M.; Rajab, A.; Seuleiman, M.

    2007-01-01

    New chromatographic method for Quantitative Determination of Omeprazole in its Pharmaceutical Products was produced. Omeprazole and its degradation components were well separated in same chromatogram by using high perfume liquid chromatography (HPLC). The new analytical method has been validated by these characteristic tests (accuracy, precision, range, linearity, specificity/selectivity, limit of detection (LOD) and limit of quantitative (LOQ) ).(author)

  5. New chromatographic Methods for Separation of Lansoprazole from its Degradation Components and The Quantitative Determination in its Pharmaceutical Products

    International Nuclear Information System (INIS)

    Touma, M.; Rajab, A.

    2009-01-01

    New chromatographic method was found for Quantitative Determination of Lansoprazole in its pharmaceutical products. Lansoprazole and its degradation components were well separated in same chromatogram by using high perfume liquid chromatography (HPLC). The new analytical method has been validated by these characteristic tests (accuracy, precision, range, linearity, specificity/selectivity, limit of detection (LOD) and limit of quantitative (LOQ)). (author)

  6. Complete family of separability criteria

    International Nuclear Information System (INIS)

    Doherty, Andrew C.; Spedalieri, Federico M.; Parrilo, Pablo A.

    2004-01-01

    We introduce a family of separability criteria that are based on the existence of extensions of a bipartite quantum state ρ to a larger number of parties satisfying certain symmetry properties. It can be easily shown that all separable states have the required extensions, so the nonexistence of such an extension for a particular state implies that the state is entangled. One of the main advantages of this approach is that searching for the extension can be cast as a convex optimization problem known as a semidefinite program. Whenever an extension does not exist, the dual optimization constructs an explicit entanglement witness for the particular state. These separability tests can be ordered in a hierarchical structure whose first step corresponds to the well-known positive partial transpose (Peres-Horodecki) criterion, and each test in the hierarchy is at least as powerful as the preceding one. This hierarchy is complete, in the sense that any entangled state is guaranteed to fail a test at some finite point in the hierarchy, thus showing it is entangled. The entanglement witnesses corresponding to each step of the hierarchy have well-defined and very interesting algebraic properties that, in turn, allow for a characterization of the interior of the set of positive maps. Coupled with some recent results on the computational complexity of the separability problem, which has been shown to be NP hard, this hierarchy of tests gives a complete and also computationally and theoretically appealing characterization of mixed bipartite entangled states

  7. [Influences of ion-suppressors on retention behaviors of nine food additives in reversed-phase high performance liquid chromatographic separation].

    Science.gov (United States)

    Zhao, Yonggang; Chen, Xiaohong; Li, Xiaoping; Yao, Shanshan; Jin, Micong

    2011-10-01

    The influences of ion-suppressors on retention behaviors of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in reversed-phase high performance liquid chromatographic (RP-HPLC) separation were investigated. The organic modification effects of acids, i. e. , trifluoroacetic acid (TFA) and buffer salts, i. e. , TFA-ammonium acetate (AmAc) were studied emphatically. The relationships between retention factors of solutes and volume percentages of ion-suppressors in the mobile phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, separately. The separation of nine food additives was completed by a gradient elution with acetonitrile-TFA (0.01%, v/v)-AmAc (2. 5 mmol/L) aqueous solution as the mobile phases. An RP-HPLC method was established for the simultaneous determination of nine food additives in red wine. In the range of 10. 0 - 100. 0 mg/L, nine food additives showed good linearity with the correlation coefficients ( r2 ) larger than 0. 999 1. The limits of detection (LODs) were in the range of 0. 33 - 2. 36 mg/L and the limits of quantification (LOQs) were in the range of 1. 11 - 7. 80 mg/L. The spiked recoveries were between 87. 61% and 108. 4% with the relative standard deviations (RSDs) of 2. 2% -9. 4%. These results are of referential significance for the rapid establishment and accu- rate optimization of RP-HPLC separation for the simultaneous determination of food additives in other foods.

  8. Spectrographic determination of lanthanides in high-purity uranium compounds, after chromatographic separation by alumina-hydrofluoric acid

    International Nuclear Information System (INIS)

    Lordello, A.R.; Abrao, A.

    1979-01-01

    A method is presented for the determination of fourteen rare earth elements in high-purity uranium compounds by emission spectrography. The rare earths are chromatographically separated from uranium by using alumina-hydrofluoric acid. Lanthanum is used both as collector and internal standard. The technique of excitation involves a total consumption of the sample in a 17 ampere direct current arc. The range of determination is about 0.005 to 0.5 μg/g uranium. The coefficient of variation for Pr, Ho, Dy, Er, Tm, Lu, Gd and Tb amounts to 10%. (Author) [pt

  9. Column chromatographic method for the separation of neodymium from uranium and other elements using poly(dibenzo-18-crown-6)

    International Nuclear Information System (INIS)

    Lad, Shila N.; Mohite, Baburao S.

    2014-01-01

    A simple and efficient column chromatographic method has been developed for the separation of U (VI), Nd (III) and other metals using poly (dibenzo-18-crown-6) as stationary phase and hippuric acid as a counter ion. The various eluting agents were found efficient eluents for Nd (III). The capacity of crown polymer for Nd (III) was found to be 0.55±0.01mmol/g. The tolerance limits of various cations and anions for Nd (III) were determined. Nd (III) was quantitatively separated from other metal ions in binary as well as multicomponent mixtures. The good separation yields were obtained and had good reproducibility (±2%). The method was simple, rapid and selective. (author)

  10. High performance liquid chromatographic separation of polycyclic aromatic hydrocarbons on microparticulate pyrrolidone and application to the analysis of shale oil

    International Nuclear Information System (INIS)

    Mourey, T.H.; Siggia, S.; Uden, P.C.; Crowley, R.J.

    1980-01-01

    A chemically bonded pyrrolidone substrate is used for the high performance liquid chromatographic separation of polycyclic aromatic hydrocarbons. The cyclic amide phase interacts electronically with the polycyclic aromatic hydrocarbons in both the normal and reversed phase modes. Separation is effected according to the number of aromatic rings and the type of ring condensation. Information obtained is very different from that observed on hydrocarbon substrates, and thus these phases can be used in a complementary fashion to give a profile of polycyclic aromatics in shale oil samples. 7 figures, 1 table

  11. Optimization of the reversed-phase high-performance liquid chromatographic separation of synthetic estrogenic and progestogenic steroids using the multi-criteria decision making method

    NARCIS (Netherlands)

    Smilde, A. K.; Bruins, C. H.; Doornbos, D. A.; Vink, J.

    1987-01-01

    The optimization of the reversed-phase high-performance liquid chromatographic separation of a mixture of ethynylestradiol, desogestrel and three related compounds is described. A procedure is used that allows the prediction of the capacity factors of each individual synthetic steroid, depending on

  12. Post-synthetic modification of MIL-101(Cr) with pyridine for high-performance liquid chromatographic separation of tocopherols.

    Science.gov (United States)

    Yang, Fang; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2015-05-01

    Effective separation of tocopherols is challenging and significant due to their structural similarity and important biological role. Here we report the post-synthetic modification of metal-organic framework (MOF) MIL-101(Cr) with pyridine for high-performance liquid chromatographic (HPLC) separation of tocopherols. Baseline separation of four tocopherols was achieved on a pyridine-grafted MIL-101(Cr) packed column within 10 min using hexane/isopropanol (96:4, v/v) as the mobile phase at a flow rate of 0.5 mL min(-1). The pyridine-grafted MIL-101(Cr) packed column gave high column efficiency (85,000 plates m(-1) for δ-tocopherol) and good precision (0.2-0.3% for retention time, 1.8-3.4% for peak area, 2.6-2.7% for peak height), and also offered much better performance than unmodified MIL-101(Cr) and commercial amino-bonded silica packed column for HPLC separation of tocopherols. The results not only show the promising application of pyridine-grafted MIL-101(Cr) as a novel stationary phase for HPLC separation of tocopherols, but also reveal a facile post-modification of MOFs to expand the application of MOFs in separation sciences. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. The Use of TOC Reconciliation as a Means of Establishing the Degree to Which Chromatographic Screening of Plastic Material Extracts for Organic Extractables Is Complete.

    Science.gov (United States)

    Jenke, Dennis; Couch, Thomas R; Robinson, Sarah J; Volz, Trent J; Colton, Raymond H

    2014-01-01

    Extracts of plastic packaging, manufacturing, and delivery systems (or their materials of construction) are analyzed by chromatographic methods to establish the system's extractables profile. The testing strategy consists of multiple orthogonal chromatographic methods, for example, gas and liquid chromatography with multiple detection strategies. Although this orthogonal testing strategy is comprehensive, it is not necessarily complete and members of the extractables profile can elude detection and/or accurate identification/quantification. Because the chromatographic methods rarely indicate that some extractables have been missed, another means of assessing the completeness of the profiling activity must be established. If the extracts are aqueous and contain no organic additives (e.g., pH buffers), then they can be analyzed for their total organic carbon content (TOC). Additionally, the TOC of an extract can be calculated based on the extractables revealed by the screening analyses. The measured and calculated TOC can be reconciled to establish the completeness and accuracy of the extractables profile. If the reconciliation is poor, then the profile is either incomplete or inaccurate and additional testing is needed to establish the complete and accurate profile. Ten test materials and components of systems were extracted and their extracts characterized for organic extractables using typical screening procedures. Measured and calculated TOC was reconciled to establish the completeness of the revealed extractables profile. When the TOC reconciliation was incomplete, the profiling was augmented with additional analytical testing to reveal the missing members of the organic extractables profile. This process is illustrated via two case studies involving aqueous extracts of sterile filters. Plastic materials and systems used to manufacture, contain, store, and deliver pharmaceutical products are extracted and the extracts analyzed to establish the materials' (or

  14. Chromatographic separation of rhenium in alumina-methanol/sulfuric acid system

    International Nuclear Information System (INIS)

    Oguma, Koichi

    1983-01-01

    The adsorption behavior of a number of metals on alumina was surveyed in a methanol-(0.005 -- 0.5) M H 2 SO 4 (3 : 1 v/v) developing solvent by thin-layer chromatography. Over the acid concentration range tested, Re(VII) does not favor the alumina phase to any great extent while the most other metals are strongly adsorbed on alumina. These findings allowed to establish a column chromatographic technique for selective separation of rhenium in a methanol-0.05 M H 2 SO 4 (3 : 1 v/v) eluent. The separation technique thus established was applied to molybdenite analysis for rhenium. About 100-mg powdered sample containing ca. 100 ppm rhenium was decomposed with HNO 3 and then evaporated nearly to dryness. The residue was dissolved in NH 4 OH and the excess NH 4 OH was expelled by evaporation to dryness. The residue was dissolved in 2.5-ml 0.5 M H 2 SO 4 and 10-ml water, the insoluble materials filtered off, and the filtrate diluted to exactly 25 ml with water. A 10-ml aliquot of this solution was mixed with 30-ml methanol and the mixture was passed through a column (diameter 15 mm, bed height 30 mm) containing 5 g of alumina. The column was then washed with 20 ml of a methanol-0.05 M H 2 SO 4 (3 : 1 v/v) mixture. Rhenium was recovered from the loaded solution and the subsequent washings, and was determined spectrophotometrically with Methylene Blue as a chromogenic reagent. The values obtained from four samples of molybdenite are in good agreement with those obtained by neutron activation analysis. The relative standard deviation (n = 4; calculated from the range) was between 2.0 and 5.2 %. (author)

  15. Vibrational Spectroscopy of Chromatographic Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Jeanne E. Pemberton

    2011-03-10

    Chromatographic separations play a central role in DOE-supported fundamental research related to energy, biological systems, the environment, and nuclear science. The overall portfolio of research activities in the Separations and Analysis Program within the DOE Office of Basic Energy Sciences includes support for activities designed to develop a molecular-level understanding of the chemical processes that underlie separations for both large-scale and analytical-scale purposes. The research effort funded by this grant award was a continuation of DOE-supported research to develop vibrational spectroscopic methods to characterize the interfacial details of separations processes at a molecular level.

  16. CHROMATOGRAPHIC SEPARATION AND SPECTRO ...

    African Journals Online (AJOL)

    Four different fractions having colours yellow, grey, orange and ... Two different dyes vis a vis: methylene blue and malachite green dyes have been separated .... hydrogen carbonate of alkaline and alkaline earth metals in the samples.

  17. New extraction chromatographic material for rhenium separation

    International Nuclear Information System (INIS)

    Lucanikova, M.; Czech Technical University, Prague; Kucera, J.; Czech Technical University, Prague; Sebesta, F.

    2008-01-01

    Three types of the extraction chromatographic materials, composed from Aliquat R 336 deposited in the polyacrylonitrile (PAN) beads and prepared by different procedures, were compared for extraction of rhenium. The best properties were exhibited when the solid extractant was prepared by impregnation of the ready-made PAN beads. Solid extractant prepared by direct coagulation of the beads from the suspension of Aliquat R 336 in solution of PAN in nitric acid differs only by lower capacity in dynamic conditions. Material prepared from the PAN solution in dimethylsulfoxide was the worst because Aliquat R 336 was washed out from the beads during coagulation of the polymer and the extraction capacity was low. As it is shown, the first two solid extractants are fully comparable with the commercial TEVA Resin. (author)

  18. Every k-separable Cech-complete space is subcompact

    NARCIS (Netherlands)

    van Mill, J.; Tkachuk, V.V.

    2015-01-01

    We establish that a Čech-complete space X must be subcompact if it has a dense subspace representable as the countable union of closed subcompact subspaces of X. In particular, if a Čech-complete space contains a dense σ-compact subspace then it is subcompact. This result is new even for separable

  19. System for separation of cortisol, 11-deoxycortisol, 17-hydroxyprogesterone and progesterone in a single chromatographic step and its application to radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, S K; McKenna, T J [St. Vincent' s Hospital, Dublin (Republic of Ireland). Dept. of Endocrinology

    1982-08-18

    A procedure for accurate, sensitive and highly specific measurement of cortisol, 11-deoxycortisol, 17-hydroxyprogesterone and progesterone is described. We have developed a chromatographic system whereby the steroids may be separated in a single passage over celite microcolumns. This permits the specific radioimmunoassay of the principal glucocorticoid in man and its ..delta..4-pregnene precursors and thus facilitates investigation of the physiological control and pathological disorders of glucocorticoid biosynthesis.

  20. A low-power pressure-and temperature-programmed separation system for a micro gas chromatograph.

    Energy Technology Data Exchange (ETDEWEB)

    Sacks, Richard D. (University of Michigan, Ann Arbor, MI); Robinson, Alex Lockwood (Advanced Sensor Technologies, Albuquerque, NM); Lambertus, Gordon R. (University of Michigan, Ann Arbor, MI); Potkay, Joseph A. (University of Michigan, Ann Arbor, MI); Wise, Kensall D. (University of Michigan, Ann Arbor, MI)

    2006-10-01

    This thesis presents the theory, design, fabrication and testing of the microvalves and columns necessary in a pressure- and temperature-programmed micro gas chromatograph ({micro}GC). Two microcolumn designs are investigated: a bonded Si-glass column having a rectangular cross section and a vapor-deposited silicon oxynitride (Sion) column having a roughly circular cross section. Both microcolumns contain integrated heaters and sensors for rapid, controlled heating. The 3.2 cm x 3.2 cm, 3 m-long silicon-glass column, coated with a non-polar polydimethylsiloxane (PDMS) stationary phase, separates 30 volatile organic compounds (VOCs) in less than 6 min. This is the most efficient micromachined column reported to date, producing greater than 4000 plates/m. The 2.7 mm x 1.4 mm Sion column eliminates the glass sealing plate and silicon substrate using deposited dielectrics and is the lowest power and fastest GC column reported to date; it requires only 11 mW to raise the column temperature by 100 C and has a response time of 11s and natural temperature ramp rate of 580 C/min. A 1 m-long PDMS-coated Sion microcolumn separates 10 VOCs in 52s. A system-based design approach was used for both columns.

  1. Research on technology of online gas chromatograph for SF6 decomposition products

    Science.gov (United States)

    Li, L.; Fan, X. P.; Zhou, Y. Y.; Tang, N.; Zou, Z. L.; Liu, M. Z.; Huang, G. J.

    2017-12-01

    Sulfur hexafluoride (SF6) decomposition products were qualitatively and quantitatively analyzed by several gas chromatographs in the laboratory. Test conditions and methods were selected and optimized to minimize and eliminate the SF6’ influences on detection of other trace components. The effective separation and detection of selected characteristic gases were achieved. And by comparison among different types of gas chromatograph, it was found that GPTR-S101 can effectively separate and detect SF6 decomposition products and has best the best detection limit and sensitivity. On the basis of GPTR-S101, online gas chromatograph for SF6decomposition products (GPTR-S201) was developed. It lays the foundation for further online monitoring and diagnosis of SF6.

  2. Chromatographic separation and continuously referenced, on-line monitoring of creatine kinase isoenzymes by use of an immobilized-enzyme microreactor

    International Nuclear Information System (INIS)

    Denton, M.S.; Bostick, W.D.; Dinsmore, S.R.; Mrochek, J.E.

    1978-01-01

    We describe a new concept in continuously referenced monitoring of the isoenzyme activities of creatine kinase (EC 2.7.3.2) after liquid-chromatographic separation. After separation on a diethylaminoethyl-Sephacel column, the three isoenzymes of creatine kinase undergo a series of upled enzyme reactions, ultimately resulting in the formation of ultraviolet-detectable NADPH. A major advantage of this detection system is the immobilized-enzyme microreactor (2 x 17 mm), which may be removed and stored refrigerated when not in use. A split-stream configuration allows self-blanking of endogenous ultraviolet-absorbing constituents in authentic sera samples, which would otherwise make definitive diagnosis and quantitation difficult or impossible. This detection system is applicable to the automated analysis of creatine kinase isoenzymes in the clinical laboratory. 5 figures; 42 references

  3. Chromatographic decontamination of medium-activity waste concentrates

    International Nuclear Information System (INIS)

    Faubel, W.; Menzler, P.M.; Sameh, A.A.

    1988-01-01

    The chromatographic decontamination of a MAW concentrate was carried out in a laboratory plant in 1-l-batches in the following way: In order to purify the nitric MAW concentrate from its solid and organic contamination products, it is passed through a filter and an absorber (SM7) for organic species. Subsequently the purified solution runs on-line through all following columns. First the main activity carrier cesium ( 137 Cs, 134 Cs) is transferred to ammonium molybdate phosphate (AMP-1) by means of a newly developed fluidized bed process. In the further course, 125 Sb is separated on metal oxides (Sb 2 O 5 , MnO 2 ) and the three-valued actinides/lanthanides on an extraction-chromatographic CMPO column. Finally the remaining 106 Ru and 60 Co activities are separated on dimethylglyoximes (DMG) coated on active carbon. (orig./RB) [de

  4. Novel chromatographic separation and carbon solid-phase extraction of acetanilide herbicide degradation products.

    Science.gov (United States)

    Shoemaker, Jody A

    2002-01-01

    One acetamide and 5 acetanilide herbicides are currently registered for use in the United States. Over the past several years, ethanesulfonic acid (ESA) and oxanilic acid (OA) degradation products of these acetanilide/acetamide herbicides have been found in U.S. ground waters and surface waters. Alachlor ESA and other acetanilide degradation products are listed on the U.S. Environmental Protection Agency's (EPA) 1998 Drinking Water Contaminant Candidate List. Consequently, EPA is interested in obtaining national occurrence data for these contaminants in drinking water. EPA currently does not have a method for determining these acetanilide degradation products in drinking water; therefore, a research method is being developed using liquid chromatography/negative ion electrospray/mass spectrometry with solid-phase extraction (SPE). A novel chromatographic separation of the acetochlor/alachlor ESA and OA structural isomers was developed which uses an ammonium acetate-methanol gradient combined with heating the analytical column to 70 degrees C. Twelve acetanilide degradates were extracted by SPE from 100 mL water samples using carbon cartridges with mean recoveries >90% and relative standard deviations < or =16%.

  5. Formation cross-sections and chromatographic separation of protactinium isotopes formed in proton-irradiated thorium metal

    Energy Technology Data Exchange (ETDEWEB)

    Radchenko, Valery; Engle, Jonathan W.; Wilson, Justin J.; Maassen, Joel R.; Nortier, Meiring F.; Birnbaum, Eva R.; John, Kevin D.; Fassbender, Michael E. [Los Alamos National Laboratory, NM (United States)

    2016-08-01

    Targeted alpha therapy (TAT) is a treatment method of increasing interest to the clinical oncology community that utilizes α-emitting radionuclides conjugated to biomolecules for the selective killing of tumor cells. Proton irradiation of thorium generates a number of α-emitting radionuclides with therapeutic potential for application via TAT. In particular, the radionuclide {sup 230}Pa is formed via the {sup 232}Th(p, 3n) nuclear reaction and partially decays to {sup 230}U, an α emitter which has recently received attention as a possible therapy nuclide. In this study, we estimate production yields for {sup 230}Pa and other Pa isotopes from proton-irradiated thorium based on cross section measurements. We adopt existing methods for the chromatographic separation of protactinium isotopes from proton irradiated thorium matrices to combine and optimize them for effective fission product decontamination.

  6. Rapid determination of environmental plutonium in large water samples by means of manganese dioxide Co-precipitation and extraction chromatographic separation

    International Nuclear Information System (INIS)

    Sidhu, R.S.; Hoff, P.

    1999-01-01

    Plutonium activity determinations in environmental water samples are routinely performed in many laboratories. Due to the low plutonium concentrations and the complexity of the plutonium aqueous chemistry, these analysis involve cumbersome preconcentration and separation procedures and long measurement times. We describe a procedure where MnO 2 (s) is used as scavenger to preconcentrate Pu prior to separation by the transuranium specific extraction chromatographic resin TRU-Resin. The ability of MnO 4 - /MnO 2 (s) to destroy organic matter and oxidise plutonium is combined with the specific behaviour of the TRU-resin for transuranium elements. The method facilitates a rapid preconcentration and separation of plutonium. With the use of this procedure, the laboratory work on one sample can be performed in one day with minimum attention. The overall yields from a 200 litre fresh- or seawater sample to a measurable Pu source are between 70-85%. (orig.)

  7. Core-shell in liquid chromatography: application for determining sulphonamides in feed and meat using conventional chromatographic systems

    Directory of Open Access Journals (Sweden)

    Antonio Armentano

    2016-12-01

    Full Text Available A C18 column packed with core-shell particles was used for the chromatographic separation of sulphonamides in feed and meat by a conventional high performance liquid chromatography system coupled with a diode array detector. Two analytical methods, already used in our laboratory, have been modified without any changes in the extraction and clean-up steps and in the liquid chromatography instrumentation. Chromatographic conditions applied on a traditional 5-μm column have been optimized on a column packed with 2.6 μm core-shell particles. A binary mobile phase [acetate buffer solution at pH 4.50 and a mixture of methanol acetonitrile 50: 50 (v/v] was employed in gradient mode at the flow rate of 1.2 mL with an injection volume of 6 μL. These chromatographic conditions allow the separation of 13 sulphonamides with an entire run of 13 minutes. Preliminary studies have been carried out comparing blanks and spiked samples of feed and meat. A good resolution and the absence of interferences were achieved in chromatograms for both matrices. Since no change was made to the sample preparation, the optimized method does not require a complete revalidation and can be used to make routine analysis faster.

  8. Chromatographic generator systems for the actinides and natural decay series elements

    International Nuclear Information System (INIS)

    McAlister, D.R.; Horwitz, E.P.

    2011-01-01

    This work describes chromatographic radionuclide generator systems for the production of actinides and natural decay series elements. The generator systems begin with alpha emitting parent radioisotopes with half-lives (T 1/2 ) of greater than one year and produce alpha or beta emitting radioisotopes with half-lives of hours to days. Chromatographic systems were chosen to minimize radiolytic damage to chromatographic supports, preserve the parent activity for repeated use, provide high purity daughter radionuclide tracers, and to minimize or eliminate the need for evaporation of solutions of the parent or daughter nuclides. Useful secondary separations involving the daughters of the initial parent radionuclide are also described. Separation systems for 210 Bi, 210 Po, 211 Pb, 212 Pb, 223 Ra, 224 Ra, 225 Ra, 225 Ac, 227 Th, 228 Th, 231 Th, 234 Th, and 239 Np are outlined in detail. (orig.)

  9. Investigation of quantitative separation of thorium, uranium, neptunium and plutonium from complex radiochemical mixtures

    International Nuclear Information System (INIS)

    Ushatskij, V.N.; Preobrazhenskaya, L.D.; Kolychev, V.B.; Gugel', E.S.

    1979-01-01

    Quantitative separation of actinides and their radiochemical purification with the aid of TBP with subsequent separation of thorium and quantitative separation of U, Np and Pu with the aid of D2EHPA have been studied. The method has been developed for quantitative extraction-chromatographic separation and radiochemical purification of nanogram amounts of U, Pu and microgram amounts of Th and Np from complex radiochemical mixtures containing both fragment radioisotopes and non-radioactive macrocomponents ( Fe,Al,Mg,Mn, Na and others). The method calls for application of one-extraction-chromatographic column with TBP and one column with D2EHPA. Thorium is separated at the first stage since it does not form complexes in a chloride solution during washing of the sorption column with 6. OM HCl. Npsup((4)) and Pusup((3)) required for separation are stabilized with the aid of hydrazine and hydroxylamine mixture. The yield of each of the above-cited actinide elements during the complete two-stage separation and at the stage of their separation varies within the range of 98.5-99.3%

  10. Determination of 21 trace impurities in UO2 with tributyl phosphate chromatographic separation-USN-inductively coupled/atomic emission spectrometric

    International Nuclear Information System (INIS)

    Hou Lieqi; Wang Shuan; Li Jie

    1996-03-01

    A method of tributyl phosphate chromatographic separation-USN-inductively coupled/atomic emission spectrometric was selected. And the parameters, interference of acid concentrations, interference of coexisting elements, selecting of flow for carrier gas, solution temperature were studied. When the sampling amount is 250 mg, the determination range for Al, Ag, Ba, Ca, Cd, Co, Cr, Cu, Fe, In, Li, Mg, Mn, Mo, Ni, Pb, Sn, Ti, V, Y and Zn are 0.2∼100 ng· -1 , recovery are 94%∼110%. The RSD (n 8) are 0.8%∼6.2%. (3 refs., 4 tabs.)

  11. Metal-organic frameworks for analytical chemistry: from sample collection to chromatographic separation.

    Science.gov (United States)

    Gu, Zhi-Yuan; Yang, Cheng-Xiong; Chang, Na; Yan, Xiu-Ping

    2012-05-15

    In modern analytical chemistry researchers pursue novel materials to meet analytical challenges such as improvements in sensitivity, selectivity, and detection limit. Metal-organic frameworks (MOFs) are an emerging class of microporous materials, and their unusual properties such as high surface area, good thermal stability, uniform structured nanoscale cavities, and the availability of in-pore functionality and outer-surface modification are attractive for diverse analytical applications. This Account summarizes our research on the analytical applications of MOFs ranging from sampling to chromatographic separation. MOFs have been either directly used or engineered to meet the demands of various analytical applications. Bulk MOFs with microsized crystals are convenient sorbents for direct application to in-field sampling and solid-phase extraction. Quartz tubes packed with MOF-5 have shown excellent stability, adsorption efficiency, and reproducibility for in-field sampling and trapping of atmospheric formaldehyde. The 2D copper(II) isonicotinate packed microcolumn has demonstrated large enhancement factors and good shape- and size-selectivity when applied to on-line solid-phase extraction of polycyclic aromatic hydrocarbons in water samples. We have explored the molecular sieving effect of MOFs for the efficient enrichment of peptides with simultaneous exclusion of proteins from biological fluids. These results show promise for the future of MOFs in peptidomics research. Moreover, nanosized MOFs and engineered thin films of MOFs are promising materials as novel coatings for solid-phase microextraction. We have developed an in situ hydrothermal growth approach to fabricate thin films of MOF-199 on etched stainless steel wire for solid-phase microextraction of volatile benzene homologues with large enhancement factors and wide linearity. Their high thermal stability and easy-to-engineer nanocrystals make MOFs attractive as new stationary phases to fabricate MOF

  12. An improved UHPLC-UV method for separation and quantification of carotenoids in vegetable crops.

    Science.gov (United States)

    Maurer, Megan M; Mein, Jonathan R; Chaudhuri, Swapan K; Constant, Howard L

    2014-12-15

    Carotenoid identification and quantitation is critical for the development of improved nutrition plant varieties. Industrial analysis of carotenoids is typically carried out on multiple crops with potentially thousands of samples per crop, placing critical needs on speed and broad utility of the analytical methods. Current chromatographic methods for carotenoid analysis have had limited industrial application due to their low throughput, requiring up to 60 min for complete separation of all compounds. We have developed an improved UHPLC-UV method that resolves all major carotenoids found in broccoli (Brassica oleracea L. var. italica), carrot (Daucus carota), corn (Zea mays), and tomato (Solanum lycopersicum). The chromatographic method is completed in 13.5 min allowing for the resolution of the 11 carotenoids of interest, including the structural isomers lutein/zeaxanthin and α-/β-carotene. Additional minor carotenoids have also been separated and identified with this method, demonstrating the utility of this method across major commercial food crops. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Insights into chromatographic separation using core-shell metal-organic frameworks: Size exclusion and polarity effects.

    Science.gov (United States)

    Qin, Weiwei; Silvestre, Martin E; Kirschhöfer, Frank; Brenner-Weiss, Gerald; Franzreb, Matthias

    2015-09-11

    Porous metal-organic frameworks (MOFs) [Cu3(BTC)2(H2O)3]n (also known as HKUST-1; BTC, benzene-1,3,5-tricarboxylic acid) were synthesized as homogeneous shell onto carboxyl functionalized magnetic microparticles through a liquid phase epitaxy (LPE) process. The as-synthesized core-shell HKUST-1 magnetic microparticles composites were characterized by XRD and SEM, and used as stationary phase in high performance liquid chromatography (HPLC). The effects of the unique properties of MOFs onto the chromatographic performance are demonstrated by the experiments. First, remarkable separation of pyridine and bipyridine is achieved, although both molecules show a strong interaction between the Cu-ions in HKUST-1 and the nitrogen atoms in their heterocyles. The difference can be explained due to size exclusion of bipyridine from the well defined pore structure of crystalline HKUST-1. Second, the enormous variety of possible interactions of sample molecules with the metal ions and linkers within MOFs allows for specifically tailored solid phases for challenging separation tasks. For example, baseline separation of three chloroaniline (CLA) isomers tested can be achieved without the need for gradient elution modes. Along with the experimental HPLC runs, in-depth modelling with a recently developed chromatography modelling software (ChromX) was applied and proofs the software to be a powerful tool for exploring the separation potential of thin MOF films. The pore diffusivity of pyridine and CLA isomers within HKUST-1 are found to be around 2.3×10(-15)m(2)s(-1). While the affinity of HKUST-1 to the tested molecules strongly differs, the maximum capacities are in the same range, with 0.37molL(-1) for pyridine and 0.23molL(-1) for CLA isomers, corresponding to 4.0 and 2.5 molecules per MOF unit cell, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Chromatographic methods

    International Nuclear Information System (INIS)

    Marhol, M.; Stary, J.

    1975-01-01

    The characteristics are given of chromatographic separation and the methods are listed. Methods and data on materials used in partition, adsorption, precipitation and ion exchange chromatography are listed and conditions are described under which ion partition takes place. Special attention is devoted to ion exchange chromatography where tables are given to show the course of values of the partition coefficients of different ions in dependence on the concentration of agents and the course of equilibrium sorptions on different materials in dependence on the solution pH. A theoretical analysis is given and the properties of the most widely used ion exchangers are listed. Experimental conditions and apparatus used for each type of chromatography are listed. (L.K.)

  15. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [99mTc(MIBI6]+

    Directory of Open Access Journals (Sweden)

    D.P. Faria

    2015-01-01

    Full Text Available Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [99mTc(MIBI6]+ as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol:chloroform (25:75, Whatman 3MM paper and ethanol:chloroform (25:75, and the more expensive ITLC-SG and 1-propanol:chloroform (10:90 were suitable systems for the direct determination of radiochemical purity of [99mTc(MIBI6]+ since impurities such as 99mTc-reduced-hydrolyzed (RH, 99mTcO4 - and [99mTc(cysteine2]- complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines.

  16. Development and Validation of a Liquid Chromatographic Method ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous determination of six human immunodeficiency virus (HIV) protease inhibitors, indinavir, saquinavir, ritonavir, amprenavir, nelfinavir and lopinavir, was developed and validated. Optimal separation was achieved on a PLRP-S 100 Å, 250 x 4.6 mm I.D. column maintained ...

  17. Test plan for demonstrating plutonium extraction from 10-L solutions using EIChrom extraction chromatographic resins

    International Nuclear Information System (INIS)

    Barney, G.S.

    1994-01-01

    Corrosive plutonium solutions stored in 10-L containers at the Plutonium Finishing Plant must be treated to convert the plutonium to a safe, solid form for storage and to remove the americium so that radiation exposure can be reduced. Extraction chromatographic resins will be tested for separating plutonium from these solutions in the laboratory. Separation parameters will be developed during the testing for large scale processing of the 10-L solutions and solutions of similar composition. Use of chromatographic resins will allow plutonium separation with minimum of chemical addition to the feed and without the need for plutonium valence adjustment. The separated plutonium will be calcined to plutonium oxide by direct solution calcination

  18. Liquid chromatographic-tandem mass spectrometric assay for ...

    African Journals Online (AJOL)

    Methods: Blood and urine samples were obtained from healthy volunteers who admitted to not being on any medications. The investigated analytes were chromatographically separated on a C18 column (Luna®-PFP 100Å column, 50 mm × 2.0 mm i.d., 3.0 μm) with the aid of a mobile phase containing A; acetonitrile (ACN) ...

  19. Preparation of methacrylate-based anion-exchange monolithic microbore column for chromatographic separation of DNA fragments and oligonucleotides

    Energy Technology Data Exchange (ETDEWEB)

    Sabarudin, Akhmad, E-mail: sabarjpn@ub.ac.id [Division of Nano-materials Science, EcoTopia Science Institute, Nagoya University, Furu-Cho, Chikusa-Ku, Nagoya 464-8603 (Japan); Department of Chemistry, Faculty of Science, Brawijaya University, Jl Veteran Malang 65145 (Indonesia); Huang, Junchao; Shu, Shin; Sakagawa, Shinnosuke [Division of Nano-materials Science, EcoTopia Science Institute, Nagoya University, Furu-Cho, Chikusa-Ku, Nagoya 464-8603 (Japan); Umemura, Tomonari, E-mail: umemura@apchem.nagoya-u.ac.jp [Division of Nano-materials Science, EcoTopia Science Institute, Nagoya University, Furu-Cho, Chikusa-Ku, Nagoya 464-8603 (Japan)

    2012-07-29

    Highlights: Black-Right-Pointing-Pointer Microbore-scale (1 mm i.d.) anion-exchange monolithic column. Black-Right-Pointing-Pointer Potentially preparative applications. Black-Right-Pointing-Pointer Separation of oligodeoxythymidylic acids and DNA fragments. - Abstract: In this paper, we report on the preparation of a microbore-scale (1 mm i.d.) anion-exchange monolithic column suitable not only for analytical purposes but also for potentially preparative applications. In order to meet the conflicting requirements of high permeability and good mechanical strength, the following two-step procedure was applied. First, an epoxy-containing monolith was synthesized by in situ copolymerization of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) within the confines of a silicosteel tubing of 1.02 mm i.d. and 1/16 Double-Prime o.d. in the presence of a ternary porogenic mixture of 1-propanol, 1,4-butanediol, and water. The monolithic matrix was subsequently converted into weak anion-exchanger via the ring-opening reaction of epoxy group with diethyl amine. The dynamic binding capacity was 21.4 mg mL{sup -1} for bovine serum albumin (BSA) at 10% breakthrough. The morphology and porous structure of this monolith were assessed by scanning electron microscope (SEM) and inverse size exclusion chromatography (ISEC). To optimize the separation efficiency, the effects of various chromatographic parameters upon the separation of DNA fragments were investigated. The resulting monolithic anion exchanger demonstrated good potential for the separation of both single- and double-stranded DNA molecules using a gradient elution with NaCl in Tris-HCl buffer (20 mM). Oligodeoxythymidylic acids (dT{sub 12}-dT{sub 18}) were successfully resolved at pH 8, while the fragments of 20 bp DNA ladder, 100 bp DNA ladder, and pBR322-HaeIII digest were efficiently separated at pH 9.

  20. Chromatographic enrichment of isotopes in hydrogen and water samples on palladium

    International Nuclear Information System (INIS)

    Andreev, B.M.; Polevoi, A.S.; Perevezentsev, A.N.

    1987-01-01

    Data on the isotopic enrichment of hydrogen and water samples by chromatography on palladium have been analyzed. Experimental data on the effect of temperature, hydrogen flow, volume of the enriched fraction, and length of the chromatographic column on the degree of separation attainable in the column have been obtained. It has been shown that the maximum separation achievable (regardless of the type of the isotope mixture) at 273 K falls with increase of hydrogen flow and volume of the enriched gas fraction recoverable from the column. A separation degree of ∼ 1040 has been achieved for a mixture of protium and deuterium in a 10-mm wide and 0.6-m long chromatographic column packed with palladium black with a grain size of 0.2-0.5 mm at 273 K and a specific hydrogen flow of 1.22 mole/m 2 x sec. For a protium-tritium mixture a separation degree of ∼ 90 has been reached in a similar column at 273 K and a specific hydrogen flow of 0.4 mole/m 2 x sec

  1. A review on sample preparation and chromatographic determination of acephate and methamidophos in

    Directory of Open Access Journals (Sweden)

    Vijay Kumar

    2015-09-01

    Full Text Available Acephate and its metabolite methamidophos are common organophosphorus insecticide used for crop protection. High uses of acephate and methamidophos have induced health issues and environmental pollution. Their undesired presence in the environment is creating ecotoxicology and may harm human health. It is therefore essential to detect the presence of acephate and methamidophos even in trace level. In this review, we have tried to accommodate successful methods of detection of acephate and methamidophos in the different biological media. Their recovery and residue analysis in different media such as vegetables, human and animal tissues have also included. The most common method for their determination is based on chromatographic separation and identification. Among different chromatographic methods, LC and GC coupled with different detectors have used. But, they both need extensive pretreatment and cleanup procedure, before undergoing chromatographic separation and identification. LC coupled with mass spectrometry (LCMS is sometime able to detect acephate and methamidophos in ppm level.

  2. Tunable thick porous silica coating fabricated by multilayer-by-multilayer bonding of silica nanoparticles for open-tubular capillary chromatographic separation.

    Science.gov (United States)

    Qu, Qishu; Liu, Yuanyuan; Shi, Wenjun; Yan, Chao; Tang, Xiaoqing

    2015-06-19

    A simple coating procedure employing a multilayer-by-multilayer process to modify the inner surface of bare fused-silica capillaries with silica nanoparticles was established. The silica nanoparticles were adsorbed onto the capillary wall via a strong electrostatic interaction between amino functional groups and silica particles. The thickness of the coating could be tuned from 130 to 600 nm by increasing the coating cycles from one to three. Both the retention factor and the resolution were greatly increased with increasing coating cycles. The loading capacity determined by naphthalene in the column with three coating cycles is 152.1 pmol. The effects of buffer concentration and pH value on the stability of the coating were evaluated. The retention reproducibility of the separation of toluene was 0.8, 1.2, 2.3, and 4.5%, respectively, for run-to-run, day-to-day, column-to-column, and batch-to-batch, respectively. The chromatographic performance of these columns was evaluated by both capillary liquid chromatography and open-tubular capillary electrochromatography (OT-CEC). Separation of aromatic hydrocarbons in the column with three coating cycles provided high theoretical plate numbers (up to 269,280 plates m(-1) for toluene) and short separation time (<15 min) by using OT-CEC mode. The method was also used to separate egg white proteins. Both acidic and basic proteins as well as four glycoisoforms were separated in a single run. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Validation for chromatographic and electrophoretic methods

    OpenAIRE

    Ribani, Marcelo; Bottoli, Carla Beatriz Grespan; Collins, Carol H.; Jardim, Isabel Cristina Sales Fontes; Melo, Lúcio Flávio Costa

    2004-01-01

    The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the dif...

  4. Chromatographic separation and detection of contaminants from whole milk powder using a chitosan-modified silver nanoparticles surface-enhanced Raman scattering device.

    Science.gov (United States)

    Li, Dan; Lv, Di Y; Zhu, Qing X; Li, Hao; Chen, Hui; Wu, Mian M; Chai, Yi F; Lu, Feng

    2017-06-01

    Methods for the on-site analysis of food contaminants are in high demand. Although portable Raman spectroscopy is commonly used to test food on-site, it can be challenge to achieve this goal with rapid detection and inexpensive substrate. In this study, we detected trace food contaminants in samples of whole milk powder using the methods that combined chromatography with surface-enhanced Raman scattering detection (SERS). We developed a simple and efficient technique to fabricate the paper with chitosan-modified silver nanoparticles as a SERS-active substrate. The soaking time of paper and the concentration of chitosan solution were optimized for chromatographic separation and SERS detection. We then studied the separation properties for real applications including complex sample matrices, and detected melamine at 1mg/L, dicyandiamide at 100mg/L and sodium sulfocyanate at 10mg/L in whole milk powder. As such, our methods have great potential for field-based detection of milk contaminants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Chemometric strategy for automatic chromatographic peak detection and background drift correction in chromatographic data.

    Science.gov (United States)

    Yu, Yong-Jie; Xia, Qiao-Ling; Wang, Sheng; Wang, Bing; Xie, Fu-Wei; Zhang, Xiao-Bing; Ma, Yun-Ming; Wu, Hai-Long

    2014-09-12

    Peak detection and background drift correction (BDC) are the key stages in using chemometric methods to analyze chromatographic fingerprints of complex samples. This study developed a novel chemometric strategy for simultaneous automatic chromatographic peak detection and BDC. A robust statistical method was used for intelligent estimation of instrumental noise level coupled with first-order derivative of chromatographic signal to automatically extract chromatographic peaks in the data. A local curve-fitting strategy was then employed for BDC. Simulated and real liquid chromatographic data were designed with various kinds of background drift and degree of overlapped chromatographic peaks to verify the performance of the proposed strategy. The underlying chromatographic peaks can be automatically detected and reasonably integrated by this strategy. Meanwhile, chromatograms with BDC can be precisely obtained. The proposed method was used to analyze a complex gas chromatography dataset that monitored quality changes in plant extracts during storage procedure. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Dual liquid and gas chromatograph system

    Science.gov (United States)

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  7. High-performance liquid chromatographic quantitation of desmosine plus isodesmosine in elastin and whole tissue hydrolysates

    International Nuclear Information System (INIS)

    Soskel, N.T.

    1987-01-01

    Quantitation of desmosine and isodesmosine, the major crosslinks in elastin, has been of interest because of their uniqueness and use as markers of that protein. Accurate measurement of these crosslinks may allow determination of elastin degradation in vivo and elastin content in tissues, obviating lengthy extraction procedures. We have developed a method of quantitating desmosine plus isodesmosine in hydrolysates of tissue and insoluble elastin using high-performance liquid chromatographic separation and absorbance detection that is rapid (21-35 min) and sensitive (accurate linearity from 100 pmol to 5 nmol). This method has been used to quantitate desmosines in elastin from bovine nuchal ligament and lung and in whole aorta from hamsters. The ability to completely separate [ 3 H]lysine from desmosine plus isodesmosine allows the method to be used to study incorporation of lysine into crosslinks in elastin

  8. Chromatographic Techniques for Rare Earth Elements Analysis

    Science.gov (United States)

    Chen, Beibei; He, Man; Zhang, Huashan; Jiang, Zucheng; Hu, Bin

    2017-04-01

    The present capability of rare earth element (REE) analysis has been achieved by the development of two instrumental techniques. The efficiency of spectroscopic methods was extraordinarily improved for the detection and determination of REE traces in various materials. On the other hand, the determination of REEs very often depends on the preconcentration and separation of REEs, and chromatographic techniques are very powerful tools for the separation of REEs. By coupling with sensitive detectors, many ambitious analytical tasks can be fulfilled. Liquid chromatography is the most widely used technique. Different combinations of stationary phases and mobile phases could be used in ion exchange chromatography, ion chromatography, ion-pair reverse-phase chromatography and some other techniques. The application of gas chromatography is limited because only volatile compounds of REEs can be separated. Thin-layer and paper chromatography are techniques that cannot be directly coupled with suitable detectors, which limit their applications. For special demands, separations can be performed by capillary electrophoresis, which has very high separation efficiency.

  9. Analytical application of poly [dibenzo-18-crown-6] for chromatographic separation of thorium(IV) from uranium(VI) and other elements in glycine medium

    International Nuclear Information System (INIS)

    Kadam, R.B.; Mali, G.G.; Mohite, B.S.

    2013-01-01

    A selective and effective chromatographic separation method for thorium(IV) has been developed by using poly [dibenzo-18-crown-6] as stationary phase. The separations are carried out from glycine medium. The sorption of thorium(IV) was quantitative from 1 x 10 -2 to 1 x 10 -4 M glycine. The elution of thorium(IV) was quantitative with 2.0-8.0 M HCl, 4.0-7.0 HBr, 1.0-2.0 M HClO 4 and 5.0 M H 2 SO 4 . The capacity of poly [dibenzo-18-crown-6] for thorium(IV) was found to be 0.215 ± 0.01 mmol/g of crown polymer. The effect of concentration of glycine, metal ion, foreign ion and eluents has been studied. Thorium(IV) was separated from a number of cations in ternary as well as in multicomponent mixtures. The applicability of the proposed method was checked for the determination of thorium(IV) in real as well as geological sample. The method is simple, rapid, and selective with good reproducibility (approximately ±2 %). (author)

  10. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [{sup 99m}Tc(MIBI){sub 6}]{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Faria, D.P.; Buchpiguel, C.A.; Marques, F.L.N., E-mail: danielefaria1@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Departamento de Radiologia. Servico de Medicina Nuclear

    2015-10-15

    Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [{sup 99m}Tc(MIBI){sub 6}]{sup +} as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol: chloroform (25:75), Whatman 3MM paper and ethanol:chloroform (25:75), and the more expensive ITLC-SG and 1-propanol: chloroform (10:90) were suitable systems for the direct determination of radiochemical purity of [{sup 99m}Tc(MIBI){sub 6}]{sup +} since impurities such as {sup 99m}Tc-reduced-hydrolyzed (RH), {sup 99m}TcO4{sup -} and [{sup 99m}Tc(cysteine){sub 2}]{sup -} complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines. (author)

  11. Importance of MS selectivity and chromatographic separation in LC-MS/MS-based methods when investigating pharmaceutical metabolites in water. Dipyrone as a case of study.

    Science.gov (United States)

    Ibáñez, M; Gracia-Lor, E; Sancho, J V; Hernández, F

    2012-08-01

    Pharmaceuticals are emerging contaminants of increasing concern because of their presence in the aquatic environment and potential to reach drinking-water sources. After human and/or veterinary consumption, pharmaceuticals can be excreted in unchanged form, as the parent compound, and/or as free or conjugated metabolites. Determination of most pharmaceuticals and metabolites in the environment is commonly made by liquid chromatography (LC) coupled to mass spectrometry (MS). LC coupled to tandem MS is the technique of choice nowadays in this field. The acquisition of two selected reaction monitoring (SRM) transitions together with the retention time is the most widely accepted criterion for a safe quantification and confirmation assay. However, scarce attention is normally paid to the selectivity of the selected transitions as well as to the chromatographic separation. In this work, the importance of full spectrum acquisition high-resolution MS data using a hybrid quadrupole time-of-flight analyser and/or a suitable chromatographic separation (to reduce the possibility of co-eluting interferences) is highlighted when investigating pharmaceutical metabolites that share common fragment ions. For this purpose, the analytical challenge associated to the determination of metabolites of the widely used analgesic dipyrone (also known as metamizol) in urban wastewater is discussed. Examples are given on the possibilities of reporting false positives of dypirone metabolites by LC-MS/MS under SRM mode due to a wrong assignment of identity of the compounds detected. Copyright © 2012 John Wiley & Sons, Ltd.

  12. Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems

    Science.gov (United States)

    Shinomiya, Kazufusa; Sato, Kazuki; Yoshida, Kazunori; Tokura, Koji; Maruyama, Hiroshi; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2013-01-01

    Universal high-speed counter-current chromatograph (HSCCC) was newly designed and fabricated in our laboratory. It holds a set of four column holders symmetrically around the rotary frame at a distance of 11.2 cm from the central axis. By engaging the stationary gear on the central axis of the centrifuge to the planetary gears on the column holder shaft through a set of idle gears, two pairs of diagonally located column holders simultaneously rotate about their own axes in the opposite directions: one forward (type-J planetary motion) and the other backward (type-I planetary motion) each synchronously with the revolution. Using the eccentric coil assembly, partition efficiencies produced by these two planetary motions were compared on the separation of two different types of sugar derivatives (4-methylumbelliferyl and 5-bromo-4-chloro-3-indoxyl sugar derivatives) using organic-aqueous two-phase solvent systems composed of n-hexane/ethyl acetate/1-butanol/methanol/water and aqueous 0.1 M sodium tetraborate, respectively. With lower phase mobile, better peak resolution was obtained by the type-J forward rotation for both samples probably due to higher retention of the stationary phase. With upper phase mobile, however, similar peak resolutions were obtained between these two planetary motions for both sugar derivatives. The overall results indicate that the present universal HSCCC is useful for counter-current chromatographic separation since each planetary motion has its specific applications: e.g., vortex CCC by the type-I planetary motion and HSCCC by the type-J planetary motion both for separation of various natural and synthetic products. PMID:24267319

  13. Recent advances in metal-organic frameworks and covalent organic frameworks for sample preparation and chromatographic analysis.

    Science.gov (United States)

    Wang, Xuan; Ye, Nengsheng

    2017-12-01

    In the field of analytical chemistry, sample preparation and chromatographic separation are two core procedures. The means by which to improve the sensitivity, selectivity and detection limit of a method have become a topic of great interest. Recently, porous organic frameworks, such as metal-organic frameworks (MOFs) and covalent organic frameworks (COFs), have been widely used in this research area because of their special features, and different methods have been developed. This review summarizes the applications of MOFs and COFs in sample preparation and chromatographic stationary phases. The MOF- or COF-based solid-phase extraction (SPE), solid-phase microextraction (SPME), gas chromatography (GC), high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) methods are described. The excellent properties of MOFs and COFs have resulted in intense interest in exploring their performance and mechanisms for sample preparation and chromatographic separation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Radioimmunoassay of methaqualone in human urine compared with chromatographic methods

    International Nuclear Information System (INIS)

    Mule, S.J.; Kogan, M.; Jukofsky, D.

    1978-01-01

    The 125 I-radioimmunoassay for methaqualone in human urine was evaluated by a comparison with newly modified gas-liquid chromatographic and thin-layer chromatographic methods. The statistically significant sensitivity value for the radioimmunoassay was at 2 μg of methaqualone per liter of urine. The coefficient of variation was 2.88 -+ 0.16% intraassay. There was cross-reactivity only with metabolites of methaqualone, 4'-hydroxymethaqualone being twice as sensitively measured as methaqualone. There was complete agreement between results by radioimmunoassay and by gas-liquid chromatography in 96.7% of the samples analyzed. Only 1.2% of the radioimmunoassay values were false positives, and 2.1% false negatives (phi = 0.8917, P < 0.001). Comparisons between the thin-layer chromatographic data and the gas--liquid chromatographic or radioimmunoassay data showed less agreement because of the 50- to 200-fold higher sensitivity of the latter techniques. Gas--liquid chromatography therefore appears to represent the best reference method for the evaluation of the radioimmunoassay, which appears to be a very sensitive and reliable technique for detecting methaqualone and its metabolites in human urine

  15. Gas-chromatographic separation of hydrogen isotopes mixtures on capillary molecular sieve 5 A column at 173 K

    International Nuclear Information System (INIS)

    Bidica, N.; Preda, A.; Stanciu, V.

    2002-01-01

    Analysis of a gas mixture of hydrogen species, is not too easy because the differences in their physical-chemical properties are very small; the most different are their masses, and consequently most common analytical method appear to be the mass-spectrometry. However, the impossibility to distinguish between two ions (atomic or molecular) with the same mass renders this method as unapplicable. Another problem is the decay of tritium with production of 3 He. These disadvantages of mass-spectrometry have made that other analytical methods, like gas chromatography, to be considered and developed. Thus, there are many papers about various chromatographic columns especially prepared for hydrogen species separation but the preparation and treatment of these columns are very difficult to reproduce. Besides these, there are two other main disadvantages: column operating temperature is very low and long retention times for hydrogen species (more than half an hour) are required. However, the gas-chromatography method still remains an appropriate one. The method described in this paper was based on using a capillary molecular sieve 5A column which has been operated for this kind of separation. The retention times were relatively short, about 8-9 minutes. The carrier gas was Ne and the detector - TCD. In the paper chromatograms for various carrier flow rates and various hydrogen isotope mixtures are presented. The results demonstrated a quite good efficiency for H 2 , HD, D 2 and a not very good one for orthoH 2 -paraH 2 . (authors)

  16. Chromatographic determination of Terbinafine in presence of its Photodegradation products

    International Nuclear Information System (INIS)

    Abdel-Moety, E.M.; Kelani, K.O.; Abou Al-Alamein, A.M.

    2003-01-01

    Two different chromatographic techniques have been developed for the determination of terbinafine hydrochloride in presence of its photodegradation products. The first method depends on coupling the TLC- fractionation, on silicia gel 60F254 utilizing chloroform+methanol+25% aq. ammonia ( 12: 0.1:0.1,by volumes), with the direct scanning at 284nm. The second method describes a liquid chromatographic separation of terbinafine and its photolytic degradates on a reversed-phase column[u-Bondapak-TMC 18 (10um,25cmx4.6mm,i.d.)] using a mobile phase containing methanol+water= 80:20 (v/v) with UV-detection at 284 nm. The proposed methods showed significant stability-indication with good linearity, precision and reproducibility. (author)

  17. Evaluation and application of a mixed-mode chromatographic stationary phase in two-dimensional liquid chromatography for the separation of traditional Chinese medicine.

    Science.gov (United States)

    Wei, Zhishen; Fu, Qing; Cai, Jianfeng; Huan, Liyun; Zhao, Jianchao; Shi, Hui; Jin, Yu; Liang, Xinmiao

    2016-06-01

    In this study, two mixed-mode chromatography stationary phases (C8SAX and C8SCX) were evaluated and used to establish a two-dimensional liquid chromatography system for the separation of traditional Chinese medicine. The chromatographic properties of the mixed-mode columns were systematically evaluated by comparing with other three columns of C8, strong anion exchanger, and strong cation exchanger. The result showed that C8SAX and C8SCX had a mixed-mode retention mechanism including electrostatic interaction and hydrophobic interaction. Especially, they were suitable for separating acidic and/or basic compounds and their separation selectivities could be easily adjusted by changing pH value. Then, several off-line 2D-LC systems based on the C8SAX in the first dimension and C8SAX, C8SCX, or C8 columns in the second dimension were developed to analyze a traditional Chinese medicine-Uncaria rhynchophylla. The two-dimensional liquid chromatography system of C8SAX (pH 3.0) × C8SAX (pH 6.0) exhibited the most effective peak distribution. Finally, fractions of U. rhynchophylla prepared from the first dimension were successfully separated on the C8SAX column with a gradient pH. Thus, the mixed-mode stationary phase could provide a platform to separate the traditional Chinese medicine in practical applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Using Aspen to Teach Chromatographic Bioprocessing: A Case Study in Weak Partitioning Chromatography for Biotechnology Applications

    Science.gov (United States)

    Evans, Steven T.; Huang, Xinqun; Cramer, Steven M.

    2010-01-01

    The commercial simulator Aspen Chromatography was employed to study and optimize an important new industrial separation process, weak partitioning chromatography. This case study on antibody purification was implemented in a chromatographic separations course. Parametric simulations were performed to investigate the effect of operating parameters…

  19. Influence of column type and chromatographic conditions on the ion-exchange chromatography of immunoglobulins.

    Science.gov (United States)

    Yang, Y B; Harrison, K

    1996-08-30

    Immunoglobulins are often purified by affinity chromatography. However, this technique is costly, can result in poor resolution for subclasses (or is only group specific), and leads to possible leaching of contaminants into the purified products. Ion-exchange chromatography has shown great potential and has found an increased usage in the purification of immunoglobulins. The aim of this study is to further understand the separation mechanism with emphasis on the influence of column type and chromatographic conditions on the peak shape, selectivity and changes in the elution patterns. Included are strong cation-exchange, strong anion-exchange and weak anion-exchange columns. Five immunoglobulin G antibodies were used as test probes. Some sera and ascites were also used in the study. Among the chromatographic conditions examined were mobile phase pH, buffer type, buffer concentration, gradient rate, and column temperature. Significant differences in the chromatographic behavior (elution pattern, peak shape and selectivity) of the test samples are discussed in regard to the column type and the chromatographic conditions.

  20. TBP degradation products. Separation and gas-chromatographic determination

    International Nuclear Information System (INIS)

    Kuada, T.A.; Alem, C.M.; Matsuda, H.T.; Araujo, B.F. de; Araujo, J.A de.

    1991-11-01

    A separation method for di butylphosphate, mono butylphosphate and phosphoric acid as degradation products in organic and aqueous streams of the process containing variable amounts of actinides and fission products is described. The products were separated by extraction and after methylation the final determination was carried out by gas chromatography. TPP was used as internal standard and 5 to 500 mg/L concentration range was determined with 1 to 10% deviation depending on the concentration of organo phosphates. (author)

  1. Covalently coating dextran on macroporous polyglycidyl methacrylate microsphere enabled rapid protein chromatographic separation

    International Nuclear Information System (INIS)

    Zhang, Rongyue; Li, Qiang; Li, Juan; Zhou, Weiqing; Ye, Peili; Gao, Yang; Ma, Guanghui; Su, Zhiguo

    2012-01-01

    Protein denaturation and nonspecific adsorption on polymer media as a chromatographic support have been a problem which needs to be overcome. Macroporous poly(glycidyl methacrylate–divinylbezene) (PGMA–DVB) microspheres prepared in this study were firstly covalently coated with dextran through a three-step method. The dextran was firstly adsorbed onto the microspheres and then covalently bound to the PGMA–DVB microsphere through ether bonds which were formed by hydroxyl group reacting with epoxy group at the presence of 4-(Dimethylamino) pyridine. Finally, the coating dextran layer was crosslinked by ethylene glycol diglycidyl ether to form the continuous network coating. The coated microspheres were characterized by Fourier transform infrared spectra, scanning electron microscope, mercury porosimetry measurements, laser scanning confocal microscope, and protein adsorption experiments. Results showed that PGMA–DVB microspheres coated with dextran successfully maintained the macroporous structure and high permeability. The backpressure was only 1.69 MPa at a high flow rate of 2891 cm/h. Consequently, the hydrophilicity and biocompatibility of modified microspheres were greatly improved, and the contact angle decreased from 184° to 13°, and nonspecific adsorption of proteins was decreased to little or none. The clad dextran coating with large amounts of hydroxyl group was easily derived to be various functional groups. The derived media have great potential applications in rapid protein chromatography. - Highlights: ► Macroporous PGMA–DVB microspheres were covalently coated with dextran. ► The hydrophilicity of the coated microspheres was significantly improved. ► The irreversible adsorption of proteins was reduced to zero. ► The coated microspheres can maintain the macropore structure. ► The coated microspheres were applied to rapid protein separation.

  2. High performance liquid chromatographic separation of beryllium from some transition metals produced in high energy proton irradiations of medium mass elements: measurement of (p,7Be) cross sections

    International Nuclear Information System (INIS)

    Fassbender, M.; Spellerberg, S.; Qaim, S.M.

    1996-01-01

    A high performance liquid chromatographic (HPLC) method was developed for the separation of 7 Be formed in high energy proton irradiation of medium mass elements like Fe, Cu etc. The bulk of the target material was removed in a preseparation step. Thereafter beryllium was obtained in a high purity within a few minutes elution time using a mixture of 5 mM citric acid and 1.0 mM pyridinedicarboxylic acid as eluent and a SYKAM KO2 analytical cation-exchange column. The effect of Be-carrier on the quality of separation was investigated. The quality of separation deteriorated with the increasing Be-carrier column loading. A certain amount of Be-carrier was, however, necessary in order to quantitate the results. By using low Be-carrier amounts (∝100 μg) and determining the elution yield via a conductometric method, it was possible to obtain quantitative separation results. Besides the analytical column, a semi-preparative column was also used, and the Be separation yield determined gravimetrically. The cross sections for the (p, 7 Be) process on Cu obtained using the two separation columns (analytical and semipreparative) and the two separation yield determination methods agreed within 15%. (orig.)

  3. Chromatographic and electrophoretic approaches in ink analysis.

    Science.gov (United States)

    Zlotnick, J A; Smith, F P

    1999-10-15

    Inks are manufactured from a wide variety of substances that exhibit very different chemical behaviors. Inks designed for use in different writing instruments or printing methods have quite dissimilar components. Since the 1950s chromatographic and electrophoretic methods have played important roles in the analysis of inks, where compositional information may have bearing on the investigation of counterfeiting, fraud, forgery, and other crimes. Techniques such as paper chromatography and electrophoresis, thin-layer chromatography, high-performance liquid chromatography, gas chromatography, gel electrophoresis, and the relatively new technique of capillary electrophoresis have all been explored as possible avenues for the separation of components of inks. This paper reviews the components of different types of inks and applications of the above separation methods are reviewed.

  4. Development of a novel heavy element chemistry apparatus using the RIKEN gas-field recoil separator as a pre-separator

    International Nuclear Information System (INIS)

    Haba, H.; Morita, K.; Enomoto, S.; Morimoto, K.; Kaji, D.; Nagame, Yuichiro

    2004-01-01

    A new system was developed, that supplied the super-heavy element separated physically as the former steps to the chemical analysis devices such as a gas or liquid chromatographs. The gas jet transportation device was newly set up on the edge of existing accelerator research facilities in the Institute of Physical and Chemical Research linac building (GARIS). To conduct the chemical separation experiment of a super-heavy element of 112 in future a radioactive isotope of mercury of light homology elements was manufactured with a gas jet uniting type online multi-tracer manufacturing device. The adsorption chromatograph experiment to the gold was performed using this system. (H. Katsuta)

  5. Harnessing electro driven separation technique for the separation of selected agrochemicals

    International Nuclear Information System (INIS)

    Wan Aini Wan Ibrahim; Alam, S.M. Monjurul; Azli Sulaiman

    2008-01-01

    Electro driven separation techniques offer a different approach to the analysis of complex mixtures than do traditional pressure-driven chromatographic system; it may rely on electrophoresis, the transport of charged species through a medium by an applied field or may rely on electro driven mobile phase to provide a true chromatographic separation. In the current work the potential of an electro driven separation technique viz. Micellar electrokinetic chromatography (MEKC), is harnessed for the separation of selected agrochemicals (organophosphorus pesticides, OPPs) widely used in the agriculture sector in Malaysia. The current study compares the use of MEKC in normal mode (NM) and reverse mode (RM) for the separation of the selected OPPS. This study also highlights the difference in separations produced by performing separations in normal mode-MEKC (NM-MEKC) and reverse mode-MEKC (RM-MEKC) for the selected OPPs. In RM-MEKC, separation is conducted at acidic pH (pH 2.5 in the current work) where the electro osmotic flow (EOF) is weak whereas in NM-MEKC, the separation is carried out under basic pH (9.3 in this work) where the EOF is strong. A reverse migration order of the OPPs was observed under RM-MEKC. Separation under NM-MEKC was found to be superior to those of RM- MEKC. A comparison is also made between separations performed under sweeping-NM-MEKC and sweeping-RM-MEKC. In sweeping, the OPPs are prepared in the same background solution (BGS) minus the micelles and is adjusted to the same conductivity as the BGS. The study showed that NM-MEKC is more sensitive than RM-MEKC but sweeping-RM-MEKC is superior to sweeping-NM-MEKC. However, sweeping-RM-MEKC only separates two of the OPPs in a single run whereas sweeping-NM-MEKC separates four OPPs in a single run. The better choice of separation mode would be sweeping-NM- MEKC for more OPPs separation in a single run. (author)

  6. Application of gas chromatography in hydrogen isotope separation

    International Nuclear Information System (INIS)

    Ye Xiaoqiu; Sang Ge; Peng Lixia; Xue Yan; Cao Wei

    2008-01-01

    The principle of gas chromatographic separation of hydrogen isotopes was briefly introduced. The main technology and their development of separating hydrogen isotopes, including elution chromatography, hydrogen-displacement chromatography, self-displacement chromatography and frontal chromatography were discussed in detail. The prospect of hydrogen isotope separation by gas chromatography was presented. (authors)

  7. Chromatographic methods for the simultaneous determination of binary mixture of Saxagliptin HCl and Metformin HCl

    Directory of Open Access Journals (Sweden)

    Hanan A. Merey

    2017-12-01

    Full Text Available Two chromatographic methods were suggested for the simultaneous determination of a binary mixture containing Saxagliptin HCl (SAG and Metformin HCl (MET. First method was RP-HPLC method. Chromatographic separation was done on Kinetex™ column–C18 (4.6 × 150 mm, 2.6 µm using mobile phase consisted of acetonitrile:phosphate buffer pH = 4.5 ± 0.1 adjusted with orthophosphoric acid (13:87, v/v. Isocratic elution at a flow rate 1.5 mL/min and UV detection at 220.0 nm was performed. Second method was spectro-densitometric method. Chromatographic separation was done on precoated silica gel aluminium plates 60 F254 as a stationary phase and developing system consisting of chloroform:methanol:formic acid (80:20:0.3, by volume. The density of the separated bands was measured by UV detector at 210.0 nm. The proposed methods were validated as per the ICH guidelines parameters like Linearity, precision, accuracy, selectivity, limit of detection and limit of quantitation. Statistical comparison was done between the obtained results and those obtained by the reported methods, showing no significant difference with respect to accuracy and precision. Keywords: Saxagliptin HCl, Metformin HCl, RP-HPLC, TLC

  8. Improving accuracy and precision of ice core δD(CH4 analyses using methane pre-pyrolysis and hydrogen post-pyrolysis trapping and subsequent chromatographic separation

    Directory of Open Access Journals (Sweden)

    M. Bock

    2014-07-01

    Full Text Available Firn and polar ice cores offer the only direct palaeoatmospheric archive. Analyses of past greenhouse gas concentrations and their isotopic compositions in air bubbles in the ice can help to constrain changes in global biogeochemical cycles in the past. For the analysis of the hydrogen isotopic composition of methane (δD(CH4 or δ2H(CH4 0.5 to 1.5 kg of ice was hitherto used. Here we present a method to improve precision and reduce the sample amount for δD(CH4 measurements in (ice core air. Pre-concentrated methane is focused in front of a high temperature oven (pre-pyrolysis trapping, and molecular hydrogen formed by pyrolysis is trapped afterwards (post-pyrolysis trapping, both on a carbon-PLOT capillary at −196 °C. Argon, oxygen, nitrogen, carbon monoxide, unpyrolysed methane and krypton are trapped together with H2 and must be separated using a second short, cooled chromatographic column to ensure accurate results. Pre- and post-pyrolysis trapping largely removes the isotopic fractionation induced during chromatographic separation and results in a narrow peak in the mass spectrometer. Air standards can be measured with a precision better than 1‰. For polar ice samples from glacial periods, we estimate a precision of 2.3‰ for 350 g of ice (or roughly 30 mL – at standard temperature and pressure (STP – of air with 350 ppb of methane. This corresponds to recent tropospheric air samples (about 1900 ppb CH4 of about 6 mL (STP or about 500 pmol of pure CH4.

  9. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    OpenAIRE

    Hassib, Sonia T.; Farag, Awatef E.; Elkady, Ehab F.

    2011-01-01

    Simple, accurate and precise reversed-phase liquid chromatographic (LC) and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS) and trimethoprim (TMP) in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm) based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9):acetonitrile:water (25:100:50, v/v/v) at a flow rate of 1...

  10. Studies on improved integrated membrane-based chromatographic process for bioseparation

    Science.gov (United States)

    Xu, Yanke

    To improve protein separation and purification directly from a fermentation broth, a novel membrane filtration-cum-chromatography device configuration having a relatively impermeable coated zone near the hollow fiber module outlet has been developed. The integrated membrane filtration-cum-chromatography unit packed with chromatographic beads on the shell side of the hollow fiber unit enjoys the advantages of both membrane filtration and chromatography; it allows one to load the chromatographic media directly from the fermentation broth or lysate and separate the adsorbed proteins through the subsequent elution step in a cyclic process. Interfacial polymerization was carried out to coat the bottom section of the hollow fiber membrane while leaving the rest of the hollow fiber membrane unaffected. Myoglobin (Mb), bovine serum albumin (BSA) and a-lactalbumin (a-LA) were used as model proteins in binary mixtures. Separation behaviors of binary protein mixtures were studied in devices using either an ultrafiltration (UF) membrane or a microfiltration (MF) membrane. Experimental results show that the breakthrough time and the protein loading capacities were dramatically improved after coating in both UF and MF modules. For a synthetic yeast fermentation broth feed, the Mb and a-LA elution profiles for the four consecutive cyclic runs were almost superimposable. Due to the lower transmembrane flux in this device plus the periodical washing-elution during the chromatographic separation, fouling was not a problem as it is in conventional microfiltration. A mathematical model describing the hydrodynamic and protein loading behaviors of the integrated device using UF membrane with a coated zone was developed. The simulation results for the breakthrough agree well with the experimental breakthrough curves. The optimal length of the coated zone was obtained from the simulation. A theoretical analysis of the protein mass transfer was performed using a diffusion-convection model

  11. Covalently coating dextran on macroporous polyglycidyl methacrylate microsphere enabled rapid protein chromatographic separation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Rongyue; Li, Qiang; Li, Juan; Zhou, Weiqing; Ye, Peili; Gao, Yang; Ma, Guanghui, E-mail: ghma@home.ipe.ac.cn; Su, Zhiguo

    2012-12-01

    Protein denaturation and nonspecific adsorption on polymer media as a chromatographic support have been a problem which needs to be overcome. Macroporous poly(glycidyl methacrylate-divinylbezene) (PGMA-DVB) microspheres prepared in this study were firstly covalently coated with dextran through a three-step method. The dextran was firstly adsorbed onto the microspheres and then covalently bound to the PGMA-DVB microsphere through ether bonds which were formed by hydroxyl group reacting with epoxy group at the presence of 4-(Dimethylamino) pyridine. Finally, the coating dextran layer was crosslinked by ethylene glycol diglycidyl ether to form the continuous network coating. The coated microspheres were characterized by Fourier transform infrared spectra, scanning electron microscope, mercury porosimetry measurements, laser scanning confocal microscope, and protein adsorption experiments. Results showed that PGMA-DVB microspheres coated with dextran successfully maintained the macroporous structure and high permeability. The backpressure was only 1.69 MPa at a high flow rate of 2891 cm/h. Consequently, the hydrophilicity and biocompatibility of modified microspheres were greatly improved, and the contact angle decreased from 184 Degree-Sign to 13 Degree-Sign , and nonspecific adsorption of proteins was decreased to little or none. The clad dextran coating with large amounts of hydroxyl group was easily derived to be various functional groups. The derived media have great potential applications in rapid protein chromatography. - Highlights: Black-Right-Pointing-Pointer Macroporous PGMA-DVB microspheres were covalently coated with dextran. Black-Right-Pointing-Pointer The hydrophilicity of the coated microspheres was significantly improved. Black-Right-Pointing-Pointer The irreversible adsorption of proteins was reduced to zero. Black-Right-Pointing-Pointer The coated microspheres can maintain the macropore structure. Black-Right-Pointing-Pointer The coated microspheres

  12. Chromatographic monitoring procedures in laboratory practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaplina, E G; Belova, O I; Lasunina, N A

    1976-01-01

    The Moscow Coke and Chemical Works consist of three plants in combination, viz., the coking plant, the synthetic ammonia plant using coke-oven-gas hydrogen and the oxygen plant. The plant requirements include daily analyses not only of the coke-oven gas but also of a rich gas and an ethylene fraction. The analyses are carried out in VTI-2 apparatus. The analytical data are used to calculate the calorific values and densities of the gases. The time requirements are very considerable and the laboratory has long been engaged in developing and introducing chromatographic procedures for the major constituents of coke-oven gas, rich gas and ethylene fraction. The procedure developed for the coke-oven and rich gases uses two parallel columns, one packed with molecular sieves and the other with grade KSM silica gel. Hydrogen was determined with argon as the carrier gas, and all other constituents with helium. The procedure was time-consuming and complicated. An attempt was made to separate the gases in an LKhM-7a chromatograph with a programme-controlled 50 to 250/sup 0/C heating cycle, but the procedure still had a number of serious defects and could not be recommended for regular quality control. The final variant involved two parallel columns and a procedure based on that in GOST 14920 (''Dry gas. Proximate analysis''). The chromatograph was a type KhL-69 with a 6-way cock in the gas line so that each of the columns could be brought on stream in succession. The analytical column packings were zeolite (in a 2 m column) and diatomaceous brick with 25% n-hexadecane (in a 6 m column).

  13. Gas chromatographic determination of impurities of inorganic compounds

    International Nuclear Information System (INIS)

    Drugov, Yu.S.

    1985-01-01

    Methods of concentration, separation, detection in gas chromatographic determination of impurities of inorganic compounds including low-boiling gases, reactive gases, organometallic compounds, free metals, anions, etc. are reviewed. Methods of reaction gas chromatography for determining reactive gases, water, anions, metal chelates are considered in detail as well as methods of reaction-sorption concentration and reaction gas extraction. The application of gas chromatograpny ior anaiysis of water and atmosphere contamination, for determination of impurities in highly pure solid substances and gases is described

  14. Analytical-scale separations of lanthanides : a review of techniques and fundamentals

    International Nuclear Information System (INIS)

    Nash, K. L.; Jensen, M. P.

    1999-01-01

    Separations chemistry is at the heart of most analytical procedures to determine the rare earth content of both man-made and naturally occurring materials. Such procedures are widely used in mineral exploration, fundamental geology and geochemistry, material science, and in the nuclear industry. Chromatographic methods that rely on aqueous solutions containing complexing agents sensitive to the lanthanide cationic radius and cation-exchange phase transfer reactions (using a variety of different solid media) have enjoyed the greatest success for these procedures. In this report, they will briefly summarize the most important methods for completing such analyses. they consider in some detail the basic aqueous (and two-phase) solution chemistry that accounts for separations that work well and offer explanations for why others are less successful

  15. Pseudo-stationary separation materials for highly parallel separations.

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Anup K.; Palmer, Christopher (University of Montana, Missoula, MT)

    2005-05-01

    Goal of this study was to develop and characterize novel polymeric materials as pseudostationary phases in electrokinetic chromatography. Fundamental studies have characterized the chromatographic selectivity of the materials as a function of chemical structure and molecular conformation. The selectivities of the polymers has been studied extensively, resulting in a large body of fundamental knowledge regarding the performance and selectivity of polymeric pseudostationary phases. Two polymers have also been used for amino acid and peptide separations, and with laser induced fluorescence detection. The polymers performed well for the separation of derivatized amino acids, and provided some significant differences in selectivity relative to a commonly used micellar pseudostationary phase. The polymers did not perform well for peptide separations. The polymers were compatible with laser induced fluorescence detection, indicating that they should also be compatible with chip-based separations.

  16. Sorption and chromatographic techniques for processing liquid waste of nuclear fuel cycle

    International Nuclear Information System (INIS)

    Gelis, V.M.; Milyutin, V.V.; Chuveleva, E.A.; Maslova, G.B.; Kudryavtseva, S.P.; Firsova, L.A.; Kozlitin, E.A.

    2000-01-01

    In the spent nuclear fuel processing procedures the significant quantity of high level liquid waste containing long-lived high toxic radionuclides of cesium, strontium, promethium, americium, curium, etc. is generated. Separation of those radionuclides from the waste not merely simplifies the further safe waste handling but also reduces the waste processing operation costs due to the market value of certain individual radionuclide preparations. Recovery and separation of high grade pure long-lived radionuclide preparations is frequently performed by means of chromatographic techniques. (authors)

  17. The combination of the liquid chromatograph with the nuclear magnetic resonance spectrometer

    International Nuclear Information System (INIS)

    Scott, R.P.W.

    1986-01-01

    The association of the liquid chromatograph with the NMR spectrometer would be a very powerful analytical system for the separation and identification of unknown mixtures. There are, however, some serious difficulties involved with the association of these two techniques. The historical development of NMR chromatography is outlined and some problems are discussed. (Auth.)

  18. ADSORPTION METHOD FOR SEPARATING METAL CATIONS

    Science.gov (United States)

    Khym, J.X.

    1959-03-10

    The chromatographic separation of fission product cations is discussed. By use of this method a mixture of metal cations containing Zr, Cb, Ce, Y, Ba, and Sr may be separated from one another. Mentioned as preferred exchange adsorbents are resins containing free sulfonic acid groups. Various eluants, such as tartaric acid, HCl, and citric acid, used at various acidities, are employed to effect the selective elution and separation of the various fission product cations.

  19. Gas chromatographic sensing on an optical fiber by mode-filtered light detection.

    Science.gov (United States)

    Bruckner, C A; Synovec, R E

    1996-06-01

    A chemical sensor for gas phase measurements is reported which combines the principles of chemical separation and fiber optic detection. The analyzer incorporates an annular column Chromatographic sensor, constructed by inserting a polymer-clad optical fiber into a silica capillary. Light from a helium-neon laser is launched down the fiber, producing a steady intensity distribution within the fiber, but a low background of scattered light. When sample vapor is introduced to the sensor, and an analyte-rich volume interacts with the polymer cladding, Chromatographic retention is observed simultaneously with a change in the local refractive index of the cladding. An increase in cladding refractive index (RI) causes light to be coupled out of the fiber, with detection at a right-angle to the annular column length to provide optimum S/N ratio. This detection mechanism is called mode-filtered light detection. We report a gas Chromatographic separation on a 3.1 m annular column (320 microm i.d. silica tube, 228 microm o.d. fiber with a 12 microm fluorinated silicone clad) of methane, benzene, butanone and chlorobenzene in 6 min. The annular column length was reduced to 22 cm to function as a sensor, with selected organic vapors exhibiting unique retention times and detection selectivity. The detection selectivity is determined by the analyte RI and the partition coefficient into the cladding. The calculated limit of detection (LOD) for benzene vapor is 0.03% by volume in nitrogen, and several chlorinated species had LOD values less than 1%. For binary mixtures of organic vapors, the detected response appears to be the linear combination of the two organic standards, suggesting that the annular column may be useful as a general approach for designing chemical sensors that incorporate separation and optical detection principles simultaneously.

  20. Ion chromatographic separation for analysis of radiostrontium in nuclear reprocessing solutions of high ionic strength

    International Nuclear Information System (INIS)

    Lamb, J.D.; Nordmeyer, F.R.; Drake, P.A.; Elder, M.P.; Miles, R.W.

    1989-01-01

    An ion chromatography (IC)-based method was developed for Sr 2+ concentration and separation showing high recoveries of strontium. This procedure permits complete automation. One of the potential weaknesses of the IC approach to sample preconcentration, i.e. sensitivity to solutions of high acid content, common in nuclear reprocessing solution, has been overcome by a novel application of acid suppression technology. (author) 12 refs.; 8 figs.; 3 tabs

  1. Modeling Aquatic Toxicity through Chromatographic Systems.

    Science.gov (United States)

    Fernández-Pumarega, Alejandro; Amézqueta, Susana; Farré, Sandra; Muñoz-Pascual, Laura; Abraham, Michael H; Fuguet, Elisabet; Rosés, Martí

    2017-08-01

    Environmental risk assessment requires information about the toxicity of the growing number of chemical products coming from different origins that can contaminate water and become toxicants to aquatic species or other living beings via the trophic chain. Direct toxicity measurements using sensitive aquatic species can be carried out but they may become expensive and ethically questionable. Literature refers to the use of chromatographic measurements that correlate to the toxic effect of a compound over a specific aquatic species as an alternative to get toxicity information. In this work, we have studied the similarity in the response of the toxicity to different species and we have selected eight representative aquatic species (including tadpoles, fish, water fleas, protozoan, and bacteria) with known nonspecific toxicity to chemical substances. Next, we have selected four chromatographic systems offering good perspectives for surrogation of the eight selected aquatic systems, and thus prediction of toxicity from the chromatographic measurement. Then toxicity has been correlated to the chromatographic retention factor. Satisfactory correlation results have been obtained to emulate toxicity in five of the selected aquatic species through some of the chromatographic systems. Other aquatic species with similar characteristics to these five representative ones could also be emulated by using the same chromatographic systems. The final aim of this study is to model chemical products toxicity to aquatic species by means of chromatographic systems to reduce in vivo testing.

  2. Rapid and Convenient Separation of Chitooligosaccharides by Ion-Exchange Chromatography

    Science.gov (United States)

    Wu, Yuxiao; Lu, Wei-Peng; Wang, Jianing; Gao, Yunhua; Guo, Yanchuan

    2017-12-01

    Pervious methods for separation of highly purified chitooligosaccharides was time-consuming and labor-intensive, which limited the large-scale production. This study developed a convenient ion-exchange chromatography using the ÄKTA™ avant 150 chromatographic system. Five fractions were automatically collected under detecting the absorption at 210 nm. The fractions were analyzed by high-performance liquid chromatography. It proved that they primarily comprised chitobiose, chitotriose, chitotetraose, chitopentaose, and chitohexaose, respectively, with chromatographic purities over 90%. The separation process was rapid, convenient and could be monitored on-line, which would be benefit for the mass production of chitooligosaccharides.

  3. Comprehensive two-dimensional liquid chromatographic analysis of poloxamers.

    Science.gov (United States)

    Malik, Muhammad Imran; Lee, Sanghoon; Chang, Taihyun

    2016-04-15

    Poloxamers are low molar mass triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), having number of applications as non-ionic surfactants. Comprehensive one and two-dimensional liquid chromatographic (LC) analysis of these materials is proposed in this study. The separation of oligomers of both types (PEO and PPO) is demonstrated for several commercial poloxamers. This is accomplished at the critical conditions for one of the block while interaction for the other block. Reversed phase LC at CAP of PEO allowed for oligomeric separation of triblock copolymers with regard to PPO block whereas normal phase LC at CAP of PPO renders oligomeric separation with respect to PEO block. The oligomeric separation with regard to PEO and PPO are coupled online (comprehensive 2D-LC) to reveal two-dimensional contour plots by unconventional 2D IC×IC (interaction chromatography) coupling. The study provides chemical composition mapping of both PEO and PPO, equivalent to combined molar mass and chemical composition mapping for several commercial poloxamers. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Arsenic speciation in sulfidic waters: reconciling contradictory spectroscopic and chromatographic evidence.

    Science.gov (United States)

    Planer-Friedrich, Britta; Suess, Elke; Scheinost, Andreas C; Wallschläger, Dirk

    2010-12-15

    In recent years, analytical methods have been developed that have demonstrated that soluble arsenic-sulfur species constitute a major fraction of dissolved arsenic in sulfidic waters. However, an intense debate is going on about the exact chemical nature of these compounds, since X-ray absorption spectroscopy (XAS) data generated at higher (mmol/L) concentrations suggest the presence of (oxy)thioarsenites in such waters, while ion chromatographic (IC) and mass spectroscopic data at lower (μmol/L to nmol/L) concentrations indicate the presence of (oxy)thioarsenates. In this contribution, we connect and explain these two apparently different types of results. We show by XAS that thioarsenites are the primary reaction products of arsenite and sulfide in geochemical model experiments in the complete absence of oxygen. However, thioarsenites are extremely unstable toward oxidation, and convert rapidly into thioarsenates when exposed to atmospheric oxygen, e.g., while waiting for analysis on the chromatographic autosampler. This problem can only be eliminated when the entire chromatographic process is conducted inside a glovebox. We also show that thioarsenites are unstable toward sample dilution, which is commonly employed prior to chromatographic analysis when ultrasensitive detectors like ICP-MS are used. This instability has two main reasons: if pH changes during dilution, then equilibria between individual arsenic-sulfur species rearrange rapidly due to their different stability regions within the pH range, and if pH is kept constant during dilution, then this changes the ratio between OH(-) and SH(-) in solution, which in turn shifts the underlying speciation equilibria. This problem is avoided by analyzing samples undiluted. Our studies show that thioarsenites appear as thioarsenates in IC analyses if oxygen is not excluded completely, and as arsenite if samples are diluted in alkaline anoxic medium. This also points out that thioarsenites are necessary

  5. [Sample preparation methods for chromatographic analysis of organic components in atmospheric particulate matter].

    Science.gov (United States)

    Hao, Liang; Wu, Dapeng; Guan, Yafeng

    2014-09-01

    The determination of organic composition in atmospheric particulate matter (PM) is of great importance in understanding how PM affects human health, environment, climate, and ecosystem. Organic components are also the scientific basis for emission source tracking, PM regulation and risk management. Therefore, the molecular characterization of the organic fraction of PM has become one of the priority research issues in the field of environmental analysis. Due to the extreme complexity of PM samples, chromatographic methods have been the chief selection. The common procedure for the analysis of organic components in PM includes several steps: sample collection on the fiber filters, sample preparation (transform the sample into a form suitable for chromatographic analysis), analysis by chromatographic methods. Among these steps, the sample preparation methods will largely determine the throughput and the data quality. Solvent extraction methods followed by sample pretreatment (e. g. pre-separation, derivatization, pre-concentration) have long been used for PM sample analysis, and thermal desorption methods have also mainly focused on the non-polar organic component analysis in PM. In this paper, the sample preparation methods prior to chromatographic analysis of organic components in PM are reviewed comprehensively, and the corresponding merits and limitations of each method are also briefly discussed.

  6. Chromatographic fingerprint analysis of yohimbe bark and related dietary supplements using UHPLC/UV/MS.

    Science.gov (United States)

    Sun, Jianghao; Chen, Pei

    2012-03-05

    A practical ultra high-performance liquid chromatography (UHPLC) method was developed for fingerprint analysis of and determination of yohimbine in yohimbe barks and related dietary supplements. Good separation was achieved using a Waters Acquity BEH C(18) column with gradient elution using 0.1% (v/v) aqueous ammonium hydroxide and 0.1% ammonium hydroxide in methanol as the mobile phases. The study is the first reported chromatographic method that separates corynanthine from yohimbine in yohimbe bark extract. The chromatographic fingerprint analysis was applied to the analysis of 18 yohimbe commercial dietary supplement samples. Quantitation of yohimbine, the traditional method for analysis of yohimbe barks, were also performed to evaluate the results of the fingerprint analysis. Wide variability was observed in fingerprints and yohimbine content among yohimbe dietary supplement samples. For most of the dietary supplements, the yohimbine content was not consistent with the label claims. Copyright © 2011. Published by Elsevier B.V.

  7. Rapid chromatographic separation of dissoluble Ag(I) and silver-containing nanoparticles of 1-100 nanometer in antibacterial products and environmental waters.

    Science.gov (United States)

    Zhou, Xiao-Xia; Liu, Rui; Liu, Jing-Fu

    2014-12-16

    Sensitive and rapid methods for speciation analysis of nanoparticulate Ag (NAg) and Ag(I) in complex matrices are urgently needed for understanding the environmental effects and biological toxicity of silver nanoparticles (AgNPs). Herein we report the development of a universal liquid chromatography (LC) method for rapid and high resolution separation of dissoluble Ag(I) from nanoparticles covering the entire range of 1-100 nm in 5 min. By using a 500 Å poresize amino column, and an aqueous mobile phase containing 0.1% (v/v) FL-70 (a surfactant) and 2 mM Na2S2O3 at a flow rate of 0.7 mL/min, all the nanoparticles of various species such as Ag and Ag2S were eluted in one fraction, while dissoluble Ag(I) was eluted as a baseline separated peak. The dissoluble Ag(I) was quantified by the online coupled ICP-MS with a detection limit of 0.019 μg/L. The NAg was quantified by subtracting the dissoluble Ag(I) from the total Ag content, which was determined by ICP-MS after digestion of the sample without LC separation. While the addition of FL-70 and Na2S2O3 into the mobile phase is essential to elute NAg and Ag(I) from the column, the use of 500 Å poresize column is the key to baseline separation of Ag(I) from ∼ 1 nm AgNPs. The feasibility of the proposed method was demonstrated in speciation analysis of dissoluble Ag(I) and NAg in antibacterial products and environmental waters, with very good chromatographic repeatability (relative standard deviations) in both peak area (<2%) and retention time (<0.6%), excellent spiked recoveries in the range of 84.7-102.7% for Ag(I) and 81.3-106.3% for NAg. Our work offers a novel approach to rapid and baseline separation of dissoluble metal ions from their nanoparticulate counterparts covering the whole range of 1-100 nm.

  8. Studies on Brucella interferon: Chromatographic behaviour and purification

    International Nuclear Information System (INIS)

    Bousquet-Ucla, C.; Wietzerbin, J.; Falcoff, E.

    1980-01-01

    Interferon was induced by infecting mice with Brucella suis. Serum containing interferon activity was analyzed by chromatography on Concanavalin A-Sepharose and Phenyl-Sepharose CL-4B columns. Antiviral activity was completely retained by the lectin column indicating that all the interferon molecules are glycosylated. The chromatographic behaviour of Brucella interferon on Phenyl-Sepharose CL-4B show that, like other interferons, Brucella interferon displays hydrophobic properties. However, the hydrophobicity of the interferon molecule was masked in the crude preparation and was only detectable when purified Brucella interferon was used for chromatography. The antigenic properties of Brucella interferon provided the means for developing an affinity chromatographic method resulting in about 60.000 fold purification. As in the case of viral interferon, treatment of L cells with Brucella interferon induced specific enhanced in vitro phosphorylation of a 67.000 molecular weight protein after incubation of cell extracts with doublestranded RNA and [γ- 32 p]ATP. (auth.)

  9. Precolumn derivatization followed by liquid chromatographic separation and determination of tramiprosate in rat plasma by fluorescence detector: application to pharmacokinetics.

    Science.gov (United States)

    Rao, R Nageswara; Maurya, Pawan K; Shinde, Dhananjay D; Khalid, Sara

    2011-05-15

    Alzheimer disease (AD) is characterized pathologically by extracellular amyloid deposits composed of amyloid β (Aβ) protein. A simple and rapid method using HPLC with fluorescence detector was developed and validated for determination of tramiprosate in rat plasma. Pre-column derivatization of the deproteinized rat plasma was carried out using o-phthaldialdehyde (OPA) as a fluorescent reagent in presence of 3-mercaptopropionic acid. The liquid chromatographic separation was achieved on a Kromasil C18 column using methanol:acetonitrile: 20 mM phosphate buffer pH 7.5 (8.0:17.5:74.5 v/v/v) as a mobile phase in an isocratic elution mode. The eluents were monitored by a fluorescence detector set at 330 and 450 nm of excitation and emission wavelength respectively. Vigabatrin was used as an internal standard. The method was linear within the range 30.0-1000.0 ng/mL. Design of experiments (DOE) was used to evaluate the robustness of the method. The developed method was applied to study the pharmacokinetics of tramiprosate in rats. Copyright © 2011. Published by Elsevier B.V.

  10. Reverse-Phase High-Performance Liquid Chromatographic Separation of Methylated and Non-Methylated Nucleic Acid Bases

    OpenAIRE

    Madyastha, Prema; Rao, Pratima; Deobagkar, DN; Madyastha, KM

    1983-01-01

    A high-performance liquid chromatographic sepration method is described for the detection of 5-methylcytosine and 6-methyladenine in nucleic acid ext. The bases were sepd. on a Waters $C18 \\mu$ Bondapak column with a water: methanol acetic acid system. Effluents were monitored by UV absorption at 254 nm. The bases were estd. by peak heights which are proportional to the amts. of the individual bases. The method is rapid, sensitive, easy to perform and reproducible.

  11. Characterization of a chromatographic column for the production of 90Sr

    International Nuclear Information System (INIS)

    Fornaciari Iljadica, Maria C.; Furnari, Juan C.; Cohen, Isaac M.

    2003-01-01

    The experiments carried out with the objective of developing a method for 90 Sr production, associated to that of 99 Mo from 235 U fission, which is routinely performed at Centro Atomico Ezeiza, Comision Nacional de Energia Atomica, are described. The project consists of strontium separation from a nitric solution containing uranium and a variety of fission products, by retention and subsequent elution in selective chromatographic columns. Both these columns and the conditions for their use in a routine production process have been characterized. The experiments show good Sr-Ba separation, high concentration of activity for the obtained 90 Sr, and minimal losses; in addition, the non-existence of significant radiation damage, as a limiting factor of the separative capacity of the columns, has been verified. (author)

  12. Fingerprinting complex pectins by chromatographic separation combined with ELISA detection

    NARCIS (Netherlands)

    Verhoef, R.P.; Lu, Y.; Knox, J.P.; Voragen, A.G.J.; Schols, H.A.

    2009-01-01

    Enzyme-resistant pectin or modified hairy regions were subjected to size exclusion (HPSEC) and weak anion exchange (WAX) chromatography. Fractions collected after separation were tested for the presence of different pectic epitopes using the monoclonal antibodies LM2, LM5, LM6, and JIM7. Separation

  13. The chromatographic behavior of arsenic compounds on anion exchange columns with binary organic acids as mobile phases

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, J.; Goessler, W.; Kosmus, W. [Graz Univ. (Austria). Inst. fuer Analytische Chemie

    1998-03-01

    Identification and quantification of arsenic compounds was performed with high-performance liquid chromatography (HPLC) and flame atomic absorption spectrometry (FAAS) as element-specific detector. Arsenous acid, methylarsonic acid, dimethylarsinic acid, arsenic acid, arsenobetaine, and arsenocholine were separated on two anion-exchange columns (Synchropak Q 300 and PRP-X 100) with different binary organic acids as mobile phases. The influence of chromatographic parameters, such as pH and the concentration of the mobile phase were investigated. An unusual chromatographic behavior of arsenous acid was observed when tartaric acid was used as mobile phase. (orig.)

  14. Principles of qualitative analysis in the chromatographic context.

    Science.gov (United States)

    Valcárcel, M; Cárdenas, S; Simonet, B M; Carrillo-Carrión, C

    2007-07-27

    This article presents the state of the art of qualitative analysis in the framework of the chromatographic analysis. After establishing the differences between two main classes of qualitative analysis (analyte identification and sample classification/qualification) the particularities of instrumental qualitative analysis are commented on. Qualitative chromatographic analysis for sample classification/qualification through the so-called chromatographic fingerprint (for complex samples) or the volatiles profile (through the direct coupling headspace-mass spectrometry using the chromatograph as interface) is discussed. Next, more technical exposition of the qualitative chromatographic information is presented supported by a variety of representative examples.

  15. Chromatographic cation exchange separation of decigram quantities of californium and other transplutonium elements

    Energy Technology Data Exchange (ETDEWEB)

    Benker, D.E.; Chattin, F.R.; Collins, E.D.; Knauer, J.B.; Orr, P.B.; Ross, R.G.; Wiggins, J.T.

    1980-01-01

    Decigram quantities of highly radioactive transplutonium elements are routinely partitioned at TRU by chromatographic elution from cation resin using AHIB eluent. By using two high-pressure ion exchange columns, a small one for the initial loading of the feed and a large one for the elution, batch runs containing up to 200 mg of /sup 252/Cf can be made in about 5 hours (2 hours to load the feed and 3 hours for the elution). The number of effluent product fractions and the amount of actinides that must be collected in intermediate fractions are minimized by monitoring response from a flow-through alpha-detector. This process has been reliable and relatively easy to operate, and will continue to be used for partitioning transplutonium elements at TRU.

  16. Chromatographic measurement of hydrogen isotopic and permanent gas impurities in tritium

    International Nuclear Information System (INIS)

    Warner, D.K.; Kinard, C.; Bohl, D.C.

    1976-01-01

    This paper describes a gas chromatograph that was designed for dedicated analysis of hydrogen isotopic and permanent gas impurities in tritium and tritium-deuterium mixtures. The instrument that was developed substantially improved the accuracy and precision of hydrogen isotopic analysis in the 20 ppM to one mole percent range as compared with other analytical methods. Several unique design features of the instrument were required due to the radiation and isotopic exchange properties of the tritium in the samples; descriptions of these features are presented along with details of the complete chromatographic system. The experimental procedures used to calibrate the detector and statistically evaluate its performance are given, and the sources of analytical error are cited. The limitations of the present system are also discussed

  17. Determination of solute descriptors by chromatographic methods

    International Nuclear Information System (INIS)

    Poole, Colin F.; Atapattu, Sanka N.; Poole, Salwa K.; Bell, Andrea K.

    2009-01-01

    The solvation parameter model is now well established as a useful tool for obtaining quantitative structure-property relationships for chemical, biomedical and environmental processes. The model correlates a free-energy related property of a system to six free-energy derived descriptors describing molecular properties. These molecular descriptors are defined as L (gas-liquid partition coefficient on hexadecane at 298 K), V (McGowan's characteristic volume), E (excess molar refraction), S (dipolarity/polarizability), A (hydrogen-bond acidity), and B (hydrogen-bond basicity). McGowan's characteristic volume is trivially calculated from structure and the excess molar refraction can be calculated for liquids from their refractive index and easily estimated for solids. The remaining four descriptors are derived by experiment using (largely) two-phase partitioning, chromatography, and solubility measurements. In this article, the use of gas chromatography, reversed-phase liquid chromatography, micellar electrokinetic chromatography, and two-phase partitioning for determining solute descriptors is described. A large database of experimental retention factors and partition coefficients is constructed after first applying selection tools to remove unreliable experimental values and an optimized collection of varied compounds with descriptor values suitable for calibrating chromatographic systems is presented. These optimized descriptors are demonstrated to be robust and more suitable than other groups of descriptors characterizing the separation properties of chromatographic systems.

  18. Determination of solute descriptors by chromatographic methods.

    Science.gov (United States)

    Poole, Colin F; Atapattu, Sanka N; Poole, Salwa K; Bell, Andrea K

    2009-10-12

    The solvation parameter model is now well established as a useful tool for obtaining quantitative structure-property relationships for chemical, biomedical and environmental processes. The model correlates a free-energy related property of a system to six free-energy derived descriptors describing molecular properties. These molecular descriptors are defined as L (gas-liquid partition coefficient on hexadecane at 298K), V (McGowan's characteristic volume), E (excess molar refraction), S (dipolarity/polarizability), A (hydrogen-bond acidity), and B (hydrogen-bond basicity). McGowan's characteristic volume is trivially calculated from structure and the excess molar refraction can be calculated for liquids from their refractive index and easily estimated for solids. The remaining four descriptors are derived by experiment using (largely) two-phase partitioning, chromatography, and solubility measurements. In this article, the use of gas chromatography, reversed-phase liquid chromatography, micellar electrokinetic chromatography, and two-phase partitioning for determining solute descriptors is described. A large database of experimental retention factors and partition coefficients is constructed after first applying selection tools to remove unreliable experimental values and an optimized collection of varied compounds with descriptor values suitable for calibrating chromatographic systems is presented. These optimized descriptors are demonstrated to be robust and more suitable than other groups of descriptors characterizing the separation properties of chromatographic systems.

  19. Separation of different valency states of neptunium from processing solutions

    International Nuclear Information System (INIS)

    Shabana, R.; EL-Naggar, H.A.

    1990-01-01

    The three main oxidation states of neptunium (Np(IV),Np(V) and Np(V I)) have been separated from each other by solvent extraction and extraction chromatographic techniques. The separation procedure is based on a systematic study of the extraction behaviour of each oxidation state using TBP as an extractant. The purity of separated species is identified using spectrophotometry

  20. Gas chromatographic determination of calcium propionate added as preservative to bread.

    Science.gov (United States)

    Lamkin, W M; Unruh, N C; Pomeranz, Y

    1987-01-01

    A simple and rapid gas chromatographic procedure was developed for determining low concentrations of propionate added as a preservative to bread. A bread sample to be analyzed was ground in a meat grinder with a 3 mm hole plate and finely divided by rubbing through a No. 8 sieve. The propionate was then extracted into 0.050M formic acid in a blender at low speed for 5 min, and an aliquot of a filtrate was analyzed directly by gas chromatography. Chromatographic separation was accomplished on a Carbopack C column coated with 0.3% (w/w) Carbowax 20M and 0.1% (w/w) phosphoric acid. Less than 0.2 ppm propionic acid could be detected in the aqueous extract. Over the range of 0.03-0.23% calcium propionate, average relative error was -1.20% with an average coefficient of variation of 2.02%.

  1. PARTITION EFFICIENCY OF NEWLY DESIGNED LOCULAR MULTILAYER COIL FOR COUNTERCURRENT CHROMATOGRAPHIC SEPARATION OF PROTEINS USING SMALL-SCALE CROSS-AXIS COIL PLANET CENTRIFUGE WITH AQUEOUS-AQUEOUS POLYMER PHASE SYSTEMS.

    Science.gov (United States)

    Shinomiya, Kazufusa; Ito, Yoichiro

    2009-01-01

    Countercurrent chromatographic performance of the locular multilayer coil separation column newly designed in our laboratory was evaluated in terms of theoretical plate number, peak resolution and retention of the stationary phase in protein separation with an aqueous polymer phase system using the small-scale cross-axis coil planet centrifuge (X-axis CPC) fabricated in our laboratory. The locular column was made from 1.0 mm I.D., 2.0 mm O.D. or 1.5 mm I.D., 2.5 mm O.D. PTFE tubing compressed with a pair of hemostat at 2 or 4 cm intervals. The protein separation was performed using a set of stable proteins including cytochrome C, myoglobin and lysozyme with the 12.5% (w/w) polyethylene glycol 1000 and 12.5% (w/w) dibasic potassium phosphate system under 1000 rpm of column revolution. The 1.5 mm I.D., 2.5 mm O.D. locular tubing compressed at 2 cm intervals yielded better partition efficiencies than the non-clamped tubing using both lower and upper mobile phases with satisfactory retention of the stationary phase. The overall results suggest that the newly designed locular multilayer coil is useful to the preparative separation of proteins with aqueous-aqueous polymer phase system using our small-scale X-axis CPC.

  2. An automated multidimensional preparative gas chromatographic system for isolation and enrichment of trace amounts of xenon from ambient air.

    Science.gov (United States)

    Larson, Tuula; Östman, Conny; Colmsjö, Anders

    2011-04-01

    The monitoring of radioactive xenon isotopes is one of the principal methods for the detection of nuclear explosions in order to identify clandestine nuclear testing. In this work, a miniaturized, multiple-oven, six-column, preparative gas chromatograph was constructed in order to isolate trace quantities of radioactive xenon isotopes from ambient air, utilizing nitrogen as the carrier gas. The multidimensional chromatograph comprised preparative stainless steel columns packed with molecular sieves, activated carbon, and synthetic carbon adsorbents (e.g., Anasorb®-747 and Carbosphere®). A combination of purification techniques--ambient adsorption, thermal desorption, back-flushing, thermal focusing, and heart cutting--was selectively optimized to produce a well-defined xenon peak that facilitated reproducible heart cutting and accurate quantification. The chromatographic purification of a sample requires approximately 4 h and provides complete separation of xenon from potentially interfering components (such as water vapor, methane, carbon dioxide, and radon) with recovery and accuracy close to 100%. The preparative enrichment process isolates and concentrates a highly purified xenon gas fraction that is suitable for subsequent ultra-low-level γ-, ß/γ-spectroscopic or high-resolution mass spectrometric measurement (e.g., to monitor the gaseous fission products of nuclear explosions at remote locations). The Xenon Processing Unit is a free-standing, relatively lightweight, and transportable system that can be interfaced to a variety of sampling and detection systems. It has a relatively inexpensive, rugged, and compact modular (19-inch rack) design that provides easy access to all parts for maintenance and has a low power requirement.

  3. Efficient fabrication of high-capacity immobilized metal ion affinity chromatographic media: The role of the dextran-grafting process and its manipulation.

    Science.gov (United States)

    Zhao, Lan; Zhang, Jingfei; Huang, Yongdong; Li, Qiang; Zhang, Rongyue; Zhu, Kai; Suo, Jia; Su, Zhiguo; Zhang, Zhigang; Ma, Guanghui

    2016-03-01

    Novel high-capacity Ni(2+) immobilized metal ion affinity chromatographic media were prepared through the dextran-grafting process. Dextran was grafted to an allyl-activated agarose-based matrix followed by functionalization for the immobilized metal ion affinity chromatographic media. With elaborate regulation of the allylation degree, dextran was completely or partly grafted to agarose microspheres, namely, completely dextran-grafted agarose microspheres and partly dextran-grafted ones, respectively. Confocal laser scanning microscope results demonstrated that a good adjustment of dextran-grafting degree was achieved, and dextran was distributed uniformly in whole completely dextran-grafted microspheres, while just distributed around the outside of the partly dextran-grafted ones. Flow hydrodynamic properties were improved greatly after the dextran-grafting process, and the flow velocity increased by about 30% compared with that of a commercial chromatographic medium (Ni Sepharose FF). A significant improvement of protein binding performance was also achieved by the dextran-grafting process, and partly dextran-grafted Ni(2+) chelating medium had a maximum binding capacity for His-tagged lactate dehydrogenase about 2.5 times higher than that of Ni Sepharose FF. The results indicated that this novel chromatographic medium is promising for applications in high-efficiency and large-scale protein purification. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The development of a high performance liquid chromatograph with a sensitive on-stream radioactivity monitor for the analysis of 3H- and 14C-labelled gibberellins

    International Nuclear Information System (INIS)

    Reeve, D.R.; Yokota, T.; Nash, L.; Crozier, A.

    1976-01-01

    The development of a high performance liquid chromatograph for the separation of gibberellins is described. The system combines high efficiency, peak capacity, and sample capacity with rapid speed of analysis. In addition, the construction details of a sensitive on-stream radioactivity monitor are outlined. The overall versatility of the chromatograph has been demonstrated by the separation of a range of 3 H- and 14 C-labelled gibberellins and gibberellin precursors. The system also has considerable potential for the analysis of abscisic acid and acidic and neutral indoles. (author)

  5. Quantitative Mass Spectrometric Analysis of Ropivacaine and Bupivacaine in Authentic, Pharmaceutical and Spiked Human Plasma without Chromatographic Separation

    Directory of Open Access Journals (Sweden)

    Nahla N. Salama

    2009-01-01

    Full Text Available The present study employs time of flight mass spectrometry for quantitative analysis of the local anesthetic drugs ropivacaine and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL −1 for both drugs. The correlation coefficient was ≥0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%-102.75% was obtained. The method is accurate (% RE <; 5% and reproducible with intra- and inter-assay precision (RSD% <; 8.0%. The quantification limit is 23.8 ng mL −1 for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs.

  6. Quantitative Mass spectrometric Analysis of Ropivacaine and Bupivacaine in Authentic, Pharmaceutical and Spiked Human Plasma without Chromatographic Separation

    Directory of Open Access Journals (Sweden)

    Nahla N. Salama

    2009-01-01

    Full Text Available The present study employs time of flight mass spectrometry for quantitative analysis of the local anesthetic drugs ropivacaine and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL-1 for both drugs. The correlation coefficient was ≥0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%–102.75% was obtained. The method is accurate (% RE < 5% and reproducible with intra- and inter-assay precision (RSD% < 8.0%. The quantification limit is 23.8 ng mL-1 for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs.

  7. Stability-indicating liquid Chromatographic assaymethod for Opthalmic solutions containing combination of Dexamethasone and Chloramphenicol

    International Nuclear Information System (INIS)

    Rao, R.M.; Al-Ashban, R.M.; Shah, A.H.

    2004-01-01

    A selective high-performance chromatographic procedure for the stability monitoring of ophthalmic solutions containing a combination of dexamethasone and chloramphenicolis demonstrated. The separation of the active components and the degradation product of chloramphenicol (1-amino-1-(4-nitrophenyl)-propane-1, 3diol) was achieved on a u-Bondapack C-18 column ( 5 um, 300 mm x 3.9 mm) maintained at ambient temperature (15-20C) by utilizing a mobile phase consisting acidified water (5% actified water with glacial acetic acid ) : acetonitrile : triethyl amine 700 : 300 : 2and pH was adjusted to 5.0 by using 10 M Na OH. The flow rate was 1.5 ml min-1; and elutes were followed with UV-detection at 254 nm. Complete resolution of dexamethasone, chloramphenicol and its hydrolytic product could be attained. The sensitivity, accuracy and specificity were tested. The method was successfully applied in post-marketing stability of the commercial batches of ophthalmic solutions. (author)

  8. Assessment of the chromatographic lipophilicity of eight cephalosporins on different stationary phases.

    Science.gov (United States)

    Dąbrowska, Monika; Starek, Małgorzata; Komsta, Łukasz; Szafrański, Przemysław; Stasiewicz-Urban, Anna; Opoka, Włodzimierz

    2017-04-01

    The retention behaviors were investigated for a series of eight cephalosporins in thin-layer chromatography (TLC) using stationary phases of RP-2, RP-8, RP-18, NH 2 , DIOL, and CN chemically bonded silica gel. Additionally, various binary mobile phases (water/methanol and water/acetone) were used in different volume proportions. The retention behavior of the analyzed molecules was defined by R M0 constant. In addition, reversed phase high performance liquid chromatography (RP-HPLC) was performed in lipophilicity studies by using immobilized artificial membrane (IAM) stationary phase. Obtained chromatographic data (R M0 and logk' IAM ) were correlated with the lipophilicity, expressed as values of the log calculated (logP calc ) and experimental (logP exp(shake-flask) ) partition coefficient. Principal component analysis (PCA) was applied in order to obtain an overview of similarity or dissimilarity among the analyzed compounds. Hierarchical cluster analysis (HCA) was performed to compare the separation characteristics of the applied stationary phases. This study was undertaken to identify the best chromatographic system and chromatographic data processing method to enable the prediction of logP values. A comprehensive chromatographic investigation into the retention of the analyzed cephalosporins revealed a similar behavior on RP-18, RP-8 and CN stationary phases. The weak correlations obtained between experimental and certain computed lipophilicity indices revealed that R M0 and PC1/RM are relevant lipophilicity parameters and the RP-8, CN and RP-18 plates are appropriate stationary phases for lipophilicity investigation, whereas computational approaches still cannot fully replace experimentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. High-performance liquid chromatographic method for guanylhydrazone compounds.

    Science.gov (United States)

    Cerami, C; Zhang, X; Ulrich, P; Bianchi, M; Tracey, K J; Berger, B J

    1996-01-12

    A high-performance liquid chromatographic method has been developed for a series of aromatic guanylhydrazones that have demonstrated therapeutic potential as anti-inflammatory agents. The compounds were separated using octadecyl or diisopropyloctyl reversed-phase columns, with an acetonitrile gradient in water containing heptane sulfonate, tetramethylammonium chloride, and phosphoric acid. The method was used to reliably quantify levels of analyte as low as 785 ng/ml, and the detector response was linear to at least 50 micrograms/ml using a 100 microliters injection volume. The assay system was used to determine the basic pharmacokinetics of a lead compound, CNI-1493, from serum concentrations following a single intravenous injection in rats.

  10. Chromatographic methods of the measurements of the chloride compounds in troposphere and stratosphere

    International Nuclear Information System (INIS)

    Lasa, J.; Rosiek, J.

    1992-01-01

    The paper contains a description of various chromatographic techniques used for the analysis of the tropospheric techniques used for the analysis of the tropospheric and stratospheric halogenated compounds. The types of the column packings used for separation of halogenated compounds are described. Model chromatograms illustrating the separation of halogenated compounds are presented. The methods of the air sampling and injection for the packed and capillary columns were described. The methods of the preparation of gas calibration mixtures are presented. Operational conditions for electron capture detector used by the authors of quoted paper are also given. (author). 66 refs, 29 figs, 13 tabs

  11. Separation of deuteriated isotopomers of dopamine by ion-pair reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Masters, C.F.; Markey, S.P.; Mefford, I.N.; Duncan, M.W.

    1988-01-01

    The ion-pair reversed-phase separation of dopamine and deuterium-substituted dopamine isotopomers is described. Chromatographic parameters and deuterium isotope effects governing the resolution are examined and compared to the factors regulating the resolution are examined and compared to the factors regulating the resolution of the chemically distinct entities dopamine, norepinephrine, and epinephrine. The potential utility of the [ 2 H 7 ]dopamine, isotopomer as an internal standard for the high-performance liquid chromatography analysis of dopamine is demonstrated by using aluminum oxide extraction prior to chromatographic separation

  12. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    Science.gov (United States)

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  13. Development of a chromatographic separation method hyphenated to electro-spray ionization mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS): application to the lanthanides speciation analysis

    International Nuclear Information System (INIS)

    Beuvier, Ludovic

    2015-01-01

    This work focuses on the development of a chromatographic separation method coupled to both ESI-MS and ICP-MS in order to achieve the comprehensive speciation analysis of lanthanides in aqueous phase representative of back-extraction phases of advanced spent nuclear fuel treatment processes. This analytical method allowed the separation, the characterization and the quantitation of lanthanides complexes holding poly-aminocarboxylic ligands, such as DTPA and EDTA, used as complexing agents in these processes. A HILIC separation method of lanthanides complexes has been developed with an amide bonded stationary phase. A screening of a wide range of mobile phase compositions demonstrated that the adsorption mechanism was predominant. This screening allowed also obtaining optimized separation conditions. Faster analysis conditions with shorter amide column packed with sub 2 μm particles reduced analysis time by 2.5 and 25% solvent consumption. Isotopic and structural characterization by HILIC ESI-MS was performed as well as the development of external calibration quantitation method. Analytical performances of quantitation method were determined. Finally, the development of the HILIC coupling to ESI-MS and ICP-MS was achieved. A simultaneous quantitation method by ESI-MS and ICP-MS was performed to determine the species quantitative distribution in solution. Analytical performances of quantitation method were also determined. (author) [fr

  14. Highly accelerated cardiac cine parallel MRI using low-rank matrix completion and partial separability model

    Science.gov (United States)

    Lyu, Jingyuan; Nakarmi, Ukash; Zhang, Chaoyi; Ying, Leslie

    2016-05-01

    This paper presents a new approach to highly accelerated dynamic parallel MRI using low rank matrix completion, partial separability (PS) model. In data acquisition, k-space data is moderately randomly undersampled at the center kspace navigator locations, but highly undersampled at the outer k-space for each temporal frame. In reconstruction, the navigator data is reconstructed from undersampled data using structured low-rank matrix completion. After all the unacquired navigator data is estimated, the partial separable model is used to obtain partial k-t data. Then the parallel imaging method is used to acquire the entire dynamic image series from highly undersampled data. The proposed method has shown to achieve high quality reconstructions with reduction factors up to 31, and temporal resolution of 29ms, when the conventional PS method fails.

  15. The chromatographic separation of particles using optical electric fields

    DEFF Research Database (Denmark)

    Javier Alvarez, Nicolas; Jeppesen, Claus; Yvind, Kresten

    2013-01-01

    We introduce a new field-flow fractionation (FFF) technique, whereby molecules are separated based on their differential interaction (dielectrophoresis (DEP)) with optical electric fields, i.e. electric fields with frequencies in the visible and near-infrared range. The results show that a parall...

  16. A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas.

    Science.gov (United States)

    Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J; Lang, Walter

    2017-10-07

    Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system.

  17. Standard Format for Chromatographic-polarimetric System small samples assessment

    International Nuclear Information System (INIS)

    Naranjo, S.; Fajer, V.; Fonfria, C.; Patinno, R.

    2012-01-01

    The treatment of samples containing optically active substances to be evaluated as part of quality control of raw material entering industrial process, and also during the modifications exerted on it to obtain the desired final composition is still and unsolved problem for many industries. That is the case of sugarcane industry. Sometimes the troubles implied are enlarged because samples to be evaluated are not bigger than one milliliter. Reduction of gel beds in G-10 and G-50 chromatographic columns having an inner diameter of 16 mm, instead of 25, and bed heights adjustable to requirements by means of sliding stoppers to increase analytical power were evaluated with glucose and sucrose standards in concentrations from 1 to 10 g/dL, using aliquots of 1 ml without undesirable dilutions that could affect either detection or chromatographic profile. Assays with seaweed extracts gave good results that are shown. It is established the advantage to know concentration of a separated substance by the height of its peak and the savings in time and reagents resulting . Sample expanded uncertainty in both systems is compared. It is also presented several programs for data acquisition, storing and processing. (Author)

  18. Large-scale separation of amino acids by continuous displacement chromatography

    Energy Technology Data Exchange (ETDEWEB)

    DeCarli, J.P. II; Carta, G.; Byers, C.H.

    1989-10-01

    Continuous annular chromatography (CAC) is a developing technology that allows truly continuous chromatographic separations. Previous work has demonstrated the utility of this technology for the separation of various materials by isocratic elution on a bench scale. Novel applications and improved operation of the process were studied in this work, demonstrating that CAC is a versatile apparatus which is capable of separations at high throughput. Three specific separation systems were investigated. Pilot-scale separations at high loadings were performed using an industrial sugar mixture as an example of scale-up for isocratic separations. Bench-scale experiments of a low concentration metal ion mixture were performed to demonstrate stepwise elution, a chromatographic technique which decreases dilution and increases sorbent capacity. Finally, the separation of mixtures of amino acids by ion exchange was investigated to demonstrate the use of displacement development on the CAC. This technique, which perhaps has the most potential, when applied to the CAC allowed simultaneous separation and concentration of multicomponent mixtures on a continuous basis. Mathematical models were developed to describe the CAC performance and optimize the operating conditions. For all the systems investigated, the continuous separation performance of the CAC was found to be very nearly the same as the batchwise performance of conventional chromatography. The technology appears, thus, to be very promising for industrial applications.

  19. Derivative Quotient Spectrophotometry and an Eco-Friendly Micellar Chromatographic Approach with Time-Programmed UV-Detection for the Separation of Two Fluoroquinolones and Phenazopyridine

    Science.gov (United States)

    Tolba, Manar M.; Salim, Mohamed M.

    2016-01-01

    In this study, two analytical approaches were exploited for the resolution of binary mixtures of ciprofloxacin HCl (CIP) or norfloxacin (NOR) and phenazopyridine HCl (PHZ). In the first approach, the amplitudes of the first derivative of the ratio spectra were measured at 267 or 287 nm for CIP and at 268 or 291 nm for NOR. PHZ could be directly determined in the presence of CIP or NOR at 405 nm. The calibration graphs were rectilinear over the ranges of 1.0–16.0 µg/mL for CIP or NOR and 1.0–10.0 µg/mL for PHZ. In the second approach, an accurate, reliable and environmentally nontoxic micellar liquid chromatographic (MLC) method was developed. A good chromatographic separation was achieved using a 150 mm × 4.6 mm i.d., 5 µm particle size Spherisorb ODS-2 column. Eco-friendly mobile phase containing 0.12 M sodium dodecyl sulphate, 0.3% triethylamine and 6% n-butanol in 0.02 M orthophosphoric acid of pH 3.0 was pumped at a flow rate of 1 mL/min. Time programmed UV-detection was applied to allow sensitive determination of the studied drugs. The analytes were eluted without interferences in <10 min. Methocarbamol was used as an internal standard. The MLC method was found to be rectilinear over the concentration range of 0.5–20.0 μg/mL for CIP, NOR or PHZ. These optimized and validated methods were successfully applied for the simultaneous analysis of the studied drugs in their synthetic mixtures and co-formulated tablets. Moreover, the second method was further extended to the determination of these drugs in human urine with direct injection and without any pretreatment. PMID:26867555

  20. The counterintuitive role of extra-column volume in the determination of column efficiency and scaling of chromatographic processes

    NARCIS (Netherlands)

    Schultze-Jena, A.; Boon, M.A.; Bussmann, P.J.Th.; Janssen, A.E.M.; Padt, van der A.

    2017-01-01

    In industrial liquid separation processes chromatography often has a key function in the optimization of yield and purity. For the design of an industrial system, chromatographic processes are generally simulated using mathematical models, tested and optimized at laboratory level, and then scaled

  1. The counterintuitive role of extra-column volume in the determination of column efficiency and scaling of chromatographic processes

    NARCIS (Netherlands)

    Schultze-Jena, A.; Boon, M.A.; Bussmann, P.J.T.; Janssen, A.E.M.; Padt, A. van der

    2017-01-01

    In industrial liquid separation processes chromatography often has a key function in the optimization of yield and purity. For the design of an industrial system, chromatographic processes are generally simulated using mathematical models, tested and optimized at laboratory level, and then scaled up

  2. QSAR models for prediction of chromatographic behavior of homologous Fab variants.

    Science.gov (United States)

    Robinson, Julie R; Karkov, Hanne S; Woo, James A; Krogh, Berit O; Cramer, Steven M

    2017-06-01

    While quantitative structure activity relationship (QSAR) models have been employed successfully for the prediction of small model protein chromatographic behavior, there have been few reports to date on the use of this methodology for larger, more complex proteins. Recently our group generated focused libraries of antibody Fab fragment variants with different combinations of surface hydrophobicities and electrostatic potentials, and demonstrated that the unique selectivities of multimodal resins can be exploited to separate these Fab variants. In this work, results from linear salt gradient experiments with these Fabs were employed to develop QSAR models for six chromatographic systems, including multimodal (Capto MMC, Nuvia cPrime, and two novel ligand prototypes), hydrophobic interaction chromatography (HIC; Capto Phenyl), and cation exchange (CEX; CM Sepharose FF) resins. The models utilized newly developed "local descriptors" to quantify changes around point mutations in the Fab libraries as well as novel cluster descriptors recently introduced by our group. Subsequent rounds of feature selection and linearized machine learning algorithms were used to generate robust, well-validated models with high training set correlations (R 2  > 0.70) that were well suited for predicting elution salt concentrations in the various systems. The developed models then were used to predict the retention of a deamidated Fab and isotype variants, with varying success. The results represent the first successful utilization of QSAR for the prediction of chromatographic behavior of complex proteins such as Fab fragments in multimodal chromatographic systems. The framework presented here can be employed to facilitate process development for the purification of biological products from product-related impurities by in silico screening of resin alternatives. Biotechnol. Bioeng. 2017;114: 1231-1240. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Separation of compounds differing in isotopic composition

    International Nuclear Information System (INIS)

    Sievers, R.E.; Brooks, J.J.

    1975-01-01

    Compounds differing in isotopic composition are separated by introducing a mixture of the compounds into a chromatographic column containing a lanthanide chelate as a stationary phase and eluting from the column a fraction that is at least enriched with one of the compounds of the mixture. (U.S.)

  4. Recent highlights in electro-driven separations- selected applications of alkylthiol gold nanoparticles in capillary electrophoresis and capillary electro-chromatography.

    Science.gov (United States)

    Guihen, Elizabeth

    2017-09-01

    To date, alkylthiol gold nanoparticles (AuNPs) have been widely used in electro-chromatographic separation techniques as a viable alternative to traditional stationary phases. This is mainly due to their stability, chemical inertness, ease of functionality, increased phase ratio, ability to form self-assembled monolayers. They also yield versatile stationary phases with highly specific targeted functionalities. At the nanoscale region, the chemical and physical properties of a molecule display different attributes to that of the parent molecules or material, hence these features can be harnessed in electro-driven chromatographic separations. Application areas illustrating the use of AuNPs in separation science continue to grow and expand to cover many different kinds of analysis. The last decade has witnessed a successful trend in miniaturisation of chemical separation systems toward the micro and nanoscale ranges. Nanoparticle-based stationary phases fit well with performing chemical separations on microfluidic and capillary platforms. In this review the theory of the use of alkylthiol gold nanoparticles in electro-chromatographic driven separation methods will be discussed. This will be followed by details of recent and selected applications showing alkylthiol gold nanoparticles in capillary electrophoretic and open-tubular electro-chromatographic separations. This review will focus solely on alkylthiol based gold nanoparticles, therefore other kinds of chemical moieties bonded to gold nanoparticles are outside the scope of this review. Finally the future outlook of this exciting technology will be outlined in some detail in the final section. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. High-performance separation and supercritical extraction of lanthanides and actinides

    International Nuclear Information System (INIS)

    Datta, Arpita; Sujatha, K.; Kumar, R.; Sivaraman, N.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2010-01-01

    Extensive studies were carried out at Chemistry Group, IGCAR for the rapid separation of individual lanthanides and actinides using dynamic ion-exchange chromatographic technique. The atom percent fission was determined from the concentrations of the lanthanide fission products, uranium and plutonium contents of dissolver solution. These advantages were exploited to significantly reduce analysis time, liquid waste generation as well as dose to operator. Supercritical fluid extraction (SFE) of actinides from waste matrices was studied in detail at our laboratory using modified supercritical carbon dioxide (Sc-CO 2 ). Complete extraction and recovery of uranium, plutonium and americium from various matrices was achieved using Sc-CO 2 modified with suitable ligands. The technique was demonstrated for the recovery of plutonium from actual waste received from different laboratories. (author)

  6. Separation of rare earth by column chromatography using organic resins XAD/DEPHA

    Energy Technology Data Exchange (ETDEWEB)

    Zini, J.; Ferreira, J.C.; Bergamaschi, V.S.; Santos, I.; Carvalho, F.M.S., E-mail: jcferrei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (CCCH/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Celulas a Combustivel e Hidrogenio

    2013-07-01

    The designation of light and heavy rare earth was used the fractionation used in separation processes. In this study the process of separation of rare earth, in groups, by chromatographic column consisting in fixing of cations these elements in an organic resin Amberlite XAD16 functionalized with the extracting agent DEPHA and another portion functionalized with a mixture of extractors DEPHA/TOP. The preparation of these resins was performed in two forms, one directly as the extracting agent to the resin and the other to be used in ethyl alcohol. Conditioned resins were introduced in chromatographic columns in separation of groups, light and heavy, using a standard solution of cerium nitrate and standard solution of holmium nitrate groups to represent light and heavy respectively. The characterization technique used to identify the rare earth elements was Spectrometry X-Ray Fluorescence (XRF). The results using the technique of chromatography were satisfactory, obtaining 100% separation of the elements. (author)

  7. Separation of rare earth by column chromatography using organic resins XAD/DEPHA

    International Nuclear Information System (INIS)

    Zini, J.; Ferreira, J.C.; Bergamaschi, V.S.; Santos, I.; Carvalho, F.M.S.

    2013-01-01

    The designation of light and heavy rare earth was used the fractionation used in separation processes. In this study the process of separation of rare earth, in groups, by chromatographic column consisting in fixing of cations these elements in an organic resin Amberlite XAD16 functionalized with the extracting agent DEPHA and another portion functionalized with a mixture of extractors DEPHA/TOP. The preparation of these resins was performed in two forms, one directly as the extracting agent to the resin and the other to be used in ethyl alcohol. Conditioned resins were introduced in chromatographic columns in separation of groups, light and heavy, using a standard solution of cerium nitrate and standard solution of holmium nitrate groups to represent light and heavy respectively. The characterization technique used to identify the rare earth elements was Spectrometry X-Ray Fluorescence (XRF). The results using the technique of chromatography were satisfactory, obtaining 100% separation of the elements. (author)

  8. A narrow open tubular column for high efficiency liquid chromatographic separation.

    Science.gov (United States)

    Chen, Huang; Yang, Yu; Qiao, Zhenzhen; Xiang, Piliang; Ren, Jiangtao; Meng, Yunzhu; Zhang, Kaiqi; Juan Lu, Joann; Liu, Shaorong

    2018-04-30

    We report a great feature of open tubular liquid chromatography when it is run using an extremely narrow (e.g., 2 μm inner diameter) open tubular column: more than 10 million plates per meter can be achieved in less than 10 min and under an elution pressure of ca. 20 bar. The column is coated with octadecylsilane and both isocratic and gradient separations are performed. We reveal a focusing effect that may be used to interpret the efficiency enhancement. We also demonstrate the feasibility of using this technique for separating complex peptide samples. This high-resolution and fast separation technique is promising and can lead to a powerful tool for trace sample analysis.

  9. Separation of compounds differing in isotopic composition

    International Nuclear Information System (INIS)

    Sievers, R.E.; Brooks, J.J.

    1976-01-01

    Compounds differing in isotopic composition are separated by introducing a mixture of the compounds into a chromatographic column containing a lanthanide chelate as a stationary phase and eluting from the column a fraction which is at least enriched with one of the compounds of the mixture. 17 claims, no drawings

  10. Chromatographic enhancement techniques for the analysis of persistent organic pollutants in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, E.; Boden, A.; MacPherson, K.; Kolic, T. [Ontario Ministry of the Environment, Ottawa, Ontario (Canada); Dorman, F. [Restek Corporation, Belefonte, PA (United States); Cochran, J. [LECO Corporation, Las Vegas, NV (United States)

    2004-09-15

    A number of chromatographic enhancements can be made to improve resolution, reduce analysis times and increase peak capacity. Fast GC with TOFMS is able to deconvolute coeluting peaks with unique mass spectra separated by at least 150 ms. Analyte specific columns like Rtx-Dioxin2 can resolve all the 2,3,7,8 containing congeners except 1,2,3,7,8,9-HxCDF. This compound is typically present at the lowest concentration or not detected and makes up less than 1% of the TEQ. Comprehensive 2D GC can be used to separate a number of difficult coelutions for PCBs and other halogenated organics.

  11. Chromatographic Separation and Visual Detection on Wicking Microfluidic Devices: Quantitation of Cu2+ in Surface, Ground, and Drinking Water.

    Science.gov (United States)

    Bandara, Gayan C; Heist, Christopher A; Remcho, Vincent T

    2018-02-20

    Copper is widely applied in industrial and technological applications and is an essential micronutrient for humans and animals. However, exposure to high environmental levels of copper, especially through drinking water, can lead to copper toxicity, resulting in severe acute and chronic health effects. Therefore, regular monitoring of aqueous copper ions has become necessary as recent anthropogenic activities have led to elevated environmental concentrations of copper. On-site monitoring processes require an inexpensive, simple, and portable analytical approach capable of generating reliable qualitative and quantitative data efficiently. Membrane-based lateral flow microfluidic devices are ideal candidates as they facilitate rapid, inexpensive, and portable measurements. Here we present a simple, chromatographic separation approach in combination with a visual detection method for Cu 2+ quantitation, performed in a lateral flow microfluidic channel. This method appreciably minimizes interferences by incorporating a nonspecific polymer inclusion membrane (PIM) based assay with a "dot-counting" approach to quantification. In this study, hydrophobic polycaprolactone (PCL)-filled glass microfiber (GMF) membranes were used as the base substrate onto which the PIM was evenly dispensed as an array of dots. The devices thus prepared were then selectively exposed to oxygen radicals through a mask to generate a hydrophilic surface path along which the sample was wicked. Using this approach, copper concentrations from 1 to 20 ppm were quantified from 5 μL samples using only visual observation of the assay device.

  12. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Chromatographic techniques used in the laboratory scale fractionation and purification of plasma

    International Nuclear Information System (INIS)

    Siti Najila Mohd Janib; Wan Hamirul Bahrin Wan Kamal; Shaharuddin Mohd

    2004-01-01

    Chromatography is a powerful technique used in the separation as well as purification of proteins for use as biopharmaceuticals or medicines. Scientists use many different chromatographic techniques in biotechnology as they bring a molecule from its initial identification stage to the stage of it becoming a marketed product. The most commonly used of these techniques is liquid chromatography (1,C). This technique can be used to separate the target molecule from undesired contaminants, as well as to analyse the final product for the requisite purity as established by governmental regulatory groups such as the FDA. Some examples of LC techniques include: ion exchange (IEC), hydrophobic interaction (HIC), gel filtration (GF), affinity (AC) and reverse phase (RPC) chromatography. These techniques are very versatile and can be used at any stage of the purification process i.e. capture, intermediate purification phase and polishing. The choice of a particular technique is dependent upon the nature of the target protein as well as its intended final use. This paper describes the preliminary work done on the chromatographic purification of factor VIII (FVIII), factor IX (FIX), albumin and IgG from plasma. Results, in particular, in the isolation of albumin and IgG using IEC, have been promising. Preparation and production of cryoprecipitate to yield FVIII and FIX have also been successful. (Author)

  14. Extraction chromatographic method for the separation of actinides and lanthanides using EDHBA grafted AXAD-16 polymer

    Energy Technology Data Exchange (ETDEWEB)

    Akhila Maheswari, M.; Subramanian, M.S. [Department of Chemistry, Indian Institute of Technology, Chennai (India)

    2005-02-15

    A new extraction chromatographic method has been developed by grafting chloromethylated polymer support with 4-ethoxy-N,N-dihexylbutanamide (EDHBA), for the selective extraction of U(VI), Th(IV), La(III) and Nd(III) from highly acidic matrices. The developed grafted polymer has been characterized using {sup 13}C-CPMAS NMR spectroscopy, FT-NIR spectroscopy and also by CHN elemental analysis. The water regaining capacity of the grafted polymer is studied by TGA measurements and the active participation of the amide moiety towards metal ion complexation has been confirmed by Far IR spectroscopy. For the quantitative extraction of metal ions to the resin phase, various physico-chemical parameters are optimized by both static and dynamic methods. The developed amide grafted polymeric matrix shows good distribution ratio values even at high acidities, with the maximum metal sorption capacity values being 0.36, 0.69, 0.32 and 0.42mmolg{sup -1} for U(VI), Th(IV), La(III) and Nd(III), respectively, at 6M HNO{sub 3} medium. The kinetics of metal ion phase equilibration is found to be moderately fast, with t{sub 1/2} values of <6min, for all the analytes of interest. The limits of analyte quantification (LOQ) using the developed method are in the range of 15-30{mu}gL{sup -1}. Moreover, the sequential separation of the sorbed actinides and lanthanides could be achieved by first eluting with 100mL of distilled water (for actinides) followed by elution with 20mL of 0.1M EDTA (for lanthanides). The selectivity behavior and the practical applicability of the developed resin are tested using synthetic low level nuclear reprocessing mixtures and also with monazite sand. The analytical data are within 3.8% relative standard deviation, reflecting the reproducibility and reliability of the developed method.

  15. Evaluation of selectivity in homologous multimodal chromatographic systems using in silico designed antibody fragment libraries.

    Science.gov (United States)

    Karkov, Hanne Sophie; Woo, James; Krogh, Berit Olsen; Ahmadian, Haleh; Cramer, Steven M

    2015-12-24

    This study describes the in silico design, surface property analyses, production and chromatographic evaluations of a diverse set of antibody Fab fragment variants. Based on previous findings, we hypothesized that the complementarity-determining regions (CDRs) constitute important binding sites for multimodal chromatographic ligands. Given that antibodies are highly diversified molecules and in particular the CDRs, we set out to examine the generality of this result. For this purpose, four different Fab fragments with different CDRs and/or framework regions of the variable domains were identified and related variants were designed in silico. The four Fab variant libraries were subsequently generated by site-directed mutagenesis and produced by recombinant expression and affinity purification to enable examination of their chromatographic retention behavior. The effects of geometric re-arrangement of the functional moieties on the multimodal resin ligands were also investigated with respect to Fab variant retention profiles by comparing two commercially available multimodal cation-exchange ligands, Capto MMC and Nuvia cPrime, and two novel multimodal ligand prototypes. Interestingly, the chromatographic data demonstrated distinct selectivity trends between the four Fab variant libraries. For three of the Fab libraries, the CDR regions appeared as major binding sites for all multimodal ligands. In contrast, the fourth Fab library displayed a distinctly different chromatographic behavior, where Nuvia cPrime and related multimodal ligand prototypes provided markedly improved selectivity over Capto MMC. Clearly, the results illustrate that the discriminating power of multimodal ligands differs between different Fab fragments. The results are promising indications that multimodal chromatography using the appropriate multimodal ligands can be employed in downstream bioprocessing for challenging selective separation of product related variants. Copyright © 2015 Elsevier B

  16. Complete chromogen separation and analysis in double immunohistochemical stains using Photoshop-based image analysis.

    Science.gov (United States)

    Lehr, H A; van der Loos, C M; Teeling, P; Gown, A M

    1999-01-01

    Simultaneous detection of two different antigens on paraffin-embedded and frozen tissues can be accomplished by double immunohistochemistry. However, many double chromogen systems suffer from signal overlap, precluding definite signal quantification. To separate and quantitatively analyze the different chromogens, we imported images into a Macintosh computer using a CCD camera attached to a diagnostic microscope and used Photoshop software for the recognition, selection, and separation of colors. We show here that Photoshop-based image analysis allows complete separation of chromogens not only on the basis of their RGB spectral characteristics, but also on the basis of information concerning saturation, hue, and luminosity intrinsic to the digitized images. We demonstrate that Photoshop-based image analysis provides superior results compared to color separation using bandpass filters. Quantification of the individual chromogens is then provided by Photoshop using the Histogram command, which supplies information on the luminosity (corresponding to gray levels of black-and-white images) and on the number of pixels as a measure of spatial distribution. (J Histochem Cytochem 47:119-125, 1999)

  17. Separation of Pu from soil prior to determination by ICP-MS

    International Nuclear Information System (INIS)

    Nygren, U.; Baxter, D.C.

    2002-01-01

    In the determination of plutonium in environmental materials by ICP-MS, chemical separation is often needed to remove, e.g., heavy sample matrices and interference from UH + on m/z 239. This separation can be, and often is, performed in the same way as for alpha-spectrometric analysis. There are, however, somewhat different demands on separation for ICP-MS compared to alpha-spectrometry, but so far little has been published on the optimisation of separation procedures for plutonium determination by ICP-MS. This paper describes the development of a separation procedure especially suited for the determination of Pu by ICP-MS. Focus has been on parameters such as chemical yield of plutonium and decontamination from uranium, as well as time requirements and ease of performance. The separation of plutonium was performed using various resins, such as anion exchange resin and extraction chromatographic materials. The procedures were carried out on water spiked with 238 U and 240 Pu to concentrations of approximately 300 ppb and 50 ppt, respectively. The basic separation procedure was: 1. Adjustment of oxidation state for Pu 2. Loading on column 3. Rinsing using 4*5 free column volumes (FCVs) of load solution - if needed in combination with 1*5 FCVs of an other rinsing agent 4. Elution of Pu - if needed followed by evaporation and dissolution in a solution suitable for ICP-MS determination 5. Determination by high resolution ICP-MS The elution of plutonium was performed using various media, based on either reduction of Pu(IV) to Pu(III) or complex formation. The chemical yield of plutonium and the decontamination from uranium for various resin/elution combinations can be seen in Figs. 1 and 2. It was found that the most efficient separation procedure in terms of yield and uranium decontamination was the combination of two extraction chromatographic materials, UTEVA followed by TRU, and elution of Pu by 0.1 % 1-hydroxyethane-1,1-diphosphonic acid (HEDPA). In this procedure

  18. Current applications of miniaturized chromatographic and electrophoretic techniques in drug analysis.

    Science.gov (United States)

    Aturki, Zeineb; Rocco, Anna; Rocchi, Silvia; Fanali, Salvatore

    2014-12-01

    In the last decade, miniaturized separation techniques have become greatly popular in pharmaceutical analysis. Miniaturized separation methods are increasingly utilized in all processes of drug discovery as well as quality control of pharmaceutical preparation. The great advantages presented by the analytical miniaturized techniques, including high separation efficiency and resolution, rapid analysis and minimal consumption of reagents and samples, make them an attractive alternative to the conventional chromatographic methods for drug analysis. The purpose of this review is to give a general overview of the applicability of capillary electrophoresis (CE), capillary electrochromatography (CEC) and micro/capillary/nano-liquid chromatography (micro-LC/CLC/nano-LC) for the analysis of pharmaceutical formulations, active pharmaceutical ingredients (API), drug impurity testing, chiral drug separation, determination of drugs and metabolites in biological fluids. The results concerning the use of CEC, micro-LC, CLC, and nano-LC in the period 2009-2013, while for CE, those from 2012 up to the review draft are here summarized and some specific examples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Determination of hexachlorocyclohexane pesticide residues in wool fat by a combined high-performance liquid chromatographic-gas-liquid chromatographic method

    International Nuclear Information System (INIS)

    Ali, S.L.

    1978-01-01

    Beta- and gamma-hexachlorocyclohexane residues were determined in twelve wool fat samples by using a combined high-performance liquid chromatographic (HPLC)-gas-liquid chromatographic (GLC) method. After extraction and chromatographic clean-up on a silca-gel column, the sample was further purified by HPLC on a reversed-phase C-18 column with methanol as the mobile phase. The final determination was effected by GLC with a 1-mCi nickel-63 electron-capture detector. The analytical method was checked by addition of carbon-14-labelled lindane and measurement of the radioactivity in a liquid scintillation counter. (Auth.)

  20. Formation, separation and detection of evaporation residues produced in complete fusion reactions

    CERN Document Server

    Sagaidak, R N

    2015-01-01

    Some aspects of formation, separation and detection of evaporation residues (ERs) produced in complete fusion reactions induced by accelerated heavy ions are considered. These reactions allow to obtain heavy neutron-deficient nuclei and to study their properties. The statistical model analysis of the production cross sections for these nuclei obtained in a wide range of their neutron numbers allows to trace the changes in their macroscopic properties such as fission barriers. The fusion probability of massive projectile and target nuclei is of interest. Empirical estimates of this value allow to verify the predictions of theoretical models for the optimal ways of synthesis of unknown nuclei. Some peculiarities in the separation and detection of ERs in experiments are briefly considered by the example of the Ra ERs produced in the 12 C+Pb reactions. The reliable cross sections for ERs produced in very asymmetric projectile-target combination, such as 12 C+Pb, are important for the em...

  1. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins.

    Science.gov (United States)

    Kurdi, Said El; Muaileq, Dina Abu; Alhazmi, Hassan A; Bratty, Mohammed Al; Deeb, Sami El

    2017-06-27

    HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5) and precision (RSD ≤ 0.6 %). Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  2. Probabilistic peak detection for first-order chromatographic data.

    Science.gov (United States)

    Lopatka, M; Vivó-Truyols, G; Sjerps, M J

    2014-03-19

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by such a peak. The algorithm makes use of chromatographic information (i.e. the expected width of a single peak and the standard deviation of baseline noise). As prior information of the existence of a peak in a chromatographic run, we make use of the statistical overlap theory. We formulate an exhaustive set of mutually exclusive hypotheses concerning presence or absence of different peak configurations. These models are evaluated by fitting a segment of chromatographic data by least-squares. The evaluation of these competing hypotheses can be performed as a Bayesian inferential task. We outline the potential advantages of adopting this approach for peak detection and provide several examples of both improved performance and increased flexibility afforded by our approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Development of a relatively cheap and simple automated separation system for a routine separation procedure based on extraction chromatography

    International Nuclear Information System (INIS)

    Petro Zoriy; Reinhold Flucht; Mechthild Burow; Peter Ostapczuk; Reinhard Lennartz; Myroslav Zoriy

    2010-01-01

    A robust analytical method has been developed in our laboratory for the separation of radionuclides by means of extraction chromatography using an automated separation system. The proposed method is both cheap and simple and provides the advantageous, rapid and accurate separation of the element of interest. The automated separation system enables a shorter separation time by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in the chromatographic column. The present separation method was tested with two types of samples (water and urine) using UTEVA-, TRU- and Sr-specific resins for the separation of U, Th, Am, Pu and Sr. The total separation time for one radionuclide ranged from 60 to 100 min with the separation yield ranging from 68 to 98% depending on the elements separated. We used ICP-QMS, multi-low-level counter and alpha spectroscopy to measure the corresponding elements. (author)

  4. A Simple Thin Layer Chromatography Method for Separation of Selected Natural Steroid Hormones

    International Nuclear Information System (INIS)

    Nowakowska, J.; Rudnicka-Litka, K.; Ciura, K.; Pikul, P.; Piotrowicz, J.

    2015-01-01

    Chromatographic properties of seven steroids: estrogens (β-estradiol and estrone), androgens (testosterone, methyltestosterone, trans-androsterone), progesterone and cholesterol have been studied by planar chromatography with usage of High Performance Thin Layer Chromatography (HPTLC) and Thin Layer Chromatography (TLC) plates. Normal, reversed and cyano-bonded silica stationary phases were tested with five binary mobile phases (acetonitrile-water, acetonitrile-DMSO, acetonitrile-methanol, acetone-petroleum ether, acetone-water) in which the concentration of organic modifier varied from 0 to 100 % (v/v). This study reports the optimization of steroid hormones separation. Principal Component Analysis (PCA) based on calculated molecular descriptors quantitatively differentiating solutes was performed in order to investigate the similarity and dissimilarity between tested compounds. The separation abilities of mobile and stationary phases were compared based on separation factor α. Chromatographic retention data and possible retention mechanisms also were discussed. (author)

  5. Identification of homemade inorganic explosives by ion chromatographic analysis of post-blast residues.

    Science.gov (United States)

    Johns, Cameron; Shellie, Robert A; Potter, Oscar G; O'Reilly, John W; Hutchinson, Joseph P; Guijt, Rosanne M; Breadmore, Michael C; Hilder, Emily F; Dicinoski, Greg W; Haddad, Paul R

    2008-02-29

    Anions and cations of interest for the post-blast identification of homemade inorganic explosives were separated and detected by ion chromatographic (IC) methods. The ionic analytes used for identification of explosives in this study comprised 18 anions (acetate, benzoate, bromate, carbonate, chlorate, chloride, chlorite, chromate, cyanate, fluoride, formate, nitrate, nitrite, perchlorate, phosphate, sulfate, thiocyanate and thiosulfate) and 12 cations (ammonium, barium(II), calcium(II), chromium(III), ethylammonium, magnesium(II), manganese(II), methylammonium, potassium(I), sodium(I), strontium(II), and zinc(II)). Two IC separations are presented, using suppressed IC on a Dionex AS20 column with potassium hydroxide as eluent for anions, and non-suppressed IC for cations using a Dionex SCS 1 column with oxalic acid/acetonitrile as eluent. Conductivity detection was used in both cases. Detection limits for anions were in the range 2-27.4ppb, and for cations were in the range 13-115ppb. These methods allowed the explosive residue ions to be identified and separated from background ions likely to be present in the environment. Linearity (over a calibration range of 0.05-50ppm) was evaluated for both methods, with r(2) values ranging from 0.9889 to 1.000. Reproducibility over 10 consecutive injections of a 5ppm standard ranged from 0.01 to 0.22% relative standard deviation (RSD) for retention time and 0.29 to 2.16%RSD for peak area. The anion and cation separations were performed simultaneously by using two Dionex ICS-2000 chromatographs served by a single autoinjector. The efficacy of the developed methods was demonstrated by analysis of residue samples taken from witness plates and soils collected following the controlled detonation of a series of different inorganic homemade explosives. The results obtained were also confirmed by parallel analysis of the same samples by capillary electrophoresis (CE) with excellent agreement being obtained.

  6. Improved Chromatographic Bioavailability Estimations

    National Research Council Canada - National Science Library

    Dorsey, John

    1996-01-01

    .... Since the inception of reversed phase liquid chromatography there have been many attempts to correlate chromatographic retention with bioavailability and the most often used bulk measure, the octanol...

  7. Multidimensional High-Resolution Gas Chromatographic Investigations of Hydrocarbon Fuels and Various Turbine Engine Fuel Precursors.

    Science.gov (United States)

    1985-08-01

    time were spurious transits observed during the recording of the chromatographic output data. *Packaged gas purification filters supplied by Alltech ... Alltech ) that were needed for these unusual installations. When the column diameters were small and of comparable size, the assembly attach- ments at...into an MDGC system has definite advantages as separations can be made faster and with greater detectability. However, specific precautions must be

  8. A chromatographic objective function to characterise chromatograms with unknown compounds or without standards available.

    Science.gov (United States)

    Alvarez-Segura, T; Gómez-Díaz, A; Ortiz-Bolsico, C; Torres-Lapasió, J R; García-Alvarez-Coque, M C

    2015-08-28

    Getting useful chemical information from samples containing many compounds is still a challenge to analysts in liquid chromatography. The highest complexity corresponds to samples for which there is no prior knowledge about their chemical composition. Computer-based methodologies are currently considered as the most efficient tools to optimise the chromatographic resolution, and further finding the optimal separation conditions. However, most chromatographic objective functions (COFs) described in the literature to measure the resolution are based on mathematical models fitted with the information obtained from standards, and cannot be applied to samples with unknown compounds. In this work, a new COF based on the automatic measurement of the protruding part of the chromatographic peaks (or peak prominences) that indicates the number of perceptible peaks and global resolution, without the need of standards, is developed. The proposed COF was found satisfactory with regard to the peak purity criterion when applied to artificial peaks and simulated chromatograms of mixtures built using the information of standards. The approach was applied to mixtures of drugs containing unknown impurities and degradation products and to extracts of medicinal herbs, eluted with acetonitrile-water mixtures using isocratic and gradient elution. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. A comparative evaluation of different ionic liquids for arsenic species separation and determination in wine varietals by liquid chromatography - hydride generation atomic fluorescence spectrometry.

    Science.gov (United States)

    Castro Grijalba, Alexander; Fiorentini, Emiliano F; Martinez, Luis D; Wuilloud, Rodolfo G

    2016-09-02

    The application of different ionic liquids (ILs) as modifiers for chromatographic separation and determination of arsenite [As(III)], arsenate [As(V)], dimethylarsonic acid (DMA) and monomethylarsonic acid (MMA) species in wine samples, by reversed-phase high performance liquid chromatography coupled to hydride generation atomic fluorescence spectrometry detection (RP-HPLC-HG-AFS) was studied in this work. Several factors influencing the chromatographic separation of the As species, such as pH of the mobile phase, buffer solution concentration, buffer type, IL concentration and length of alkyl groups in ILs were evaluated. The complete separation of As species was achieved using a C18 column in isocratic mode with a mobile phase composed of 0.5% (v/v) 1-octyl-3-methylimidazolium chloride ([C8mim]Cl) and 5% (v/v) methanol at pH 8.5. A multivariate methodology was used to optimize the variables involved in AFS detection of As species after they were separated by HPLC. The ILs showed remarkable performance for the separation of As species, which was obtained within 18min with a resolution higher than 0.83. The limits of detection for As(III), As(V), MMA and DMA were 0.81, 0.89, 0.62 and 1.00μg As L(-1). The proposed method was applied for As speciation analysis in white and red wine samples originated from different grape varieties. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    Directory of Open Access Journals (Sweden)

    Nataša Gros

    2013-06-01

    Full Text Available This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as completely as possible. The sections—Selected Anions, Selected Cations and Metals—follow. The most essential experimental conditions used in different methods are summarized in tables for a rapid comparison. Techniques encountered in the reviewed articles comprise: direct determinations of ions in untreated samples with ion- or ion-exclusion chromatography, or electrostatic ion chromatography; matrix elimination with column-switching; pre-concentration with a chelation ion chromatography and purge-and-trap pre-concentration. Different detection methods were used: non-suppressed conductometric or suppressed conductometric, direct spectrometric or spectrometric after a post-column derivetization, and inductively coupled plasma in combination with optical emission or mass spectrometry.

  11. Synthesis and application of a macroporous silica-based polymeric octyl(phenyl)-N,N-diisobutylcarbamoylmethylphoshine oxide composite for the chromatographic separation of high level liquid waste

    International Nuclear Information System (INIS)

    Zhang, A.

    2006-01-01

    The Minor Actinides Recovery from HLW by Extraction Chromatography (MAREC) process was used mainly for the separation of minor actinides (MAs) and some specific fission products (FPs) from highly active liquid waste (HLW) by the composite CMPO/SiO 2 -P of the macroporous silica based polymeric octyl(phenyl)-N,N-diisobutylcarbamoylmethylphoshine oxide (CMPO) and others. In this study a cascade of chromatographic separation was performed on a 3.0M HNO 3 solution containing 5.0 x 10 -3 M of 13 elements, at 323 K. The cascade consisted of three columns the first and second ones were packed with CMPO/SiO 2 -P and the third with SiO 2 -P particles. The first column was employed to prepare various eluents containing saturated CMPO. The second column was used for separation into groups. The CMPO of CMPO/SiO2-P was recovered from the effluent by the third column and a CMPO-free effluent containing minor actinides was obtained. The elements contained in the simulated HLW of 3.0M HNO 3 were separated into (1) a non-adsorption group (Sr, Cs, and Ru etc.), (2) a MA-hRE (heavy rare earth)-Mo-Zr group, and (3) a lRE (light rare earth) group by eluting with 3.0M HNO 3 , 0.05M DTPA (diethylenetriaminepentaacetic acid) (pH 2.0) and HNO 3 (pH 3.5), respectively. The resultant MA-hRE-Mo-Zr mixture containing minor actinides was then separated into the groups (1) Pd-Ru, (2) MA-hRE, and (3) Mo-Zr by utilizing 3.0M HNO 3 , distilled water, and 0.05M DTPA (pH 2.0) as eluents. More than 92% of CMPO in the MA-hRE containing effluent was adsorbed by SiO 2 -P particles. The effectivity and technical feasibility of MAREC process were demonstrated. (author)

  12. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins

    Directory of Open Access Journals (Sweden)

    Kurdi Said El

    2017-06-01

    Full Text Available HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5 and precision (RSD ≤ 0.6 %. Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  13. Modification of ion chromatograph for analyses of radioactive samples

    International Nuclear Information System (INIS)

    Curfman, L.L.; Johnson, S.J.

    1979-01-01

    In ion chromatographic analysis, the sample is injected through a sample loop onto an analytical column where separation occurs. The sample then passes through a suppressor column to remove or neutralize background ions. A flow-through conductivity cell is used as a detector. Depending upon column and eluent selection, ion chromatography can be used for anion or cation analyses. Ion chromatography has proven to be a versatile analytical tool for the analysis of anions in Hanford waste samples. These radioactive samples range from caustic high salt solutions to hydrochloric acid dissolutions of insoluble sludges. Instrument modifications which provide safe and convenient handling of these samples without lengthening analysis time or altering instrument performance are described

  14. Ionic Liquid-Liquid Chromatography: A New General Purpose Separation Methodology

    OpenAIRE

    Brown, Leslie; Earle, Martyn J; Gilea, Manuela; Plechkova, Natalia V; Seddon, Kenneth R

    2017-01-01

    Ionic liquids can form biphasic solvent systems with many organic solvents and water, and these solvent systems can be used in liquid-liquid separations and countercurrent chromatography. The wide range of ionic liquids that can by synthesised, with specifically tailored properties, represents a new philosophy for the separation of organic, inorganic and bio-based materials. A customised countercurrent chromatograph has been designed and constructed specifically to allow the more viscous char...

  15. Chromatographic fingerprinting: An innovative approach for food 'identitation' and food authentication - A tutorial.

    Science.gov (United States)

    Cuadros-Rodríguez, Luis; Ruiz-Samblás, Cristina; Valverde-Som, Lucia; Pérez-Castaño, Estefanía; González-Casado, Antonio

    2016-02-25

    Fingerprinting methods describe a variety of analytical methods that provide analytical signals related to the composition of foodstuffs in a non-selective way such as by collecting a spectrum or a chromatogram. Mathematical processing of the information in such fingerprints may allow the characterisation and/or authentication of foodstuffs. In this context, the particular meaning of 'fingerprinting', in conjunction with 'profiling', is different from the original meanings used in metabolomics. This fact has produced some confusion with the use of these terms in analytical papers. Researchers coming from the metabolomic field could use 'profiling' or 'fingerprinting' on a different way to researchers who are devoted to food science. The arrival of an eclectic discipline, named 'foodomics' has not been enough to allay this terminological problem, since the authors keep on using the terms with both meanings. Thus, a first goal of this tutorial is to clarify the difference between both terms. In addition, the chemical approaches for food authentication, i.e., chemical markers, component profiling and instrumental fingerprinting, have been described. A new term, designated as 'food identitation', has been introduced in order to complete the life cycle of the chemical-based food authentication process. Chromatographic fingerprinting has been explained in detail and some strategies which could be applied has been clarified and discussed. Particularly, the strategies for chromatographic signals acquisition and chromatographic data handling are unified in a single framework. Finally, an overview about the applications of chromatographic (GC and LC) fingerprints in food authentication using different chemometric techniques has been included. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Identification of organic iodocompounds in the PUREX process with the help of methods for chromatographic separation and spectrometric detection as well as characterization of their behavior during extraction. Final report

    International Nuclear Information System (INIS)

    Gaul, G.; Gibau, F.; Knoechel, A.

    1993-01-01

    In the system HNO 3 KI, Dodecan and TBP the radiolytic reactive behaviour of the described compounds during the dissolution of nuclear fuel elements was simulated. External γ-irradiation gave the best informations. As a consequence of radiolyticly induced reactions several volatile and non-volatile iodoorganic compounds like iodoalkanes, iodonitroalkanes and iodonitroalkylphosphates are formed. They were separated by gaschromatography (GC) and high performance liquid chromatography (HPLC). For HPLC a special photolytic/electrochemical detector with comparable sensitivity like the electroncapture detector in the GC-field was developed. With the help of the two described chromatographic techniques the different iodoorganic compounds could be separated singularily or in groups of isomers. The separation of all compounds demands two-dimensional chromatographies including the capillary-SFC, which was not available for this project. Most of the iodoorganic compounds could be identified by comparison of the retention times of well known compounds. In the other cases, the compounds were studied mass-spectrometrically. Unfortunately all available ionisation techniques (EI; CI; FAB) were too hard for the labile C-I-bond. Therefore an identification of these compounds was not possible. In any case, instructive fingerprint spectra are available enabling relationships between the generation of the iodoorganic compounds and the reaction conditions during their formation. (orig.) [de

  17. Probabilistic peak detection for first-order chromatographic data

    NARCIS (Netherlands)

    Lopatka, M.; Vivó-Truyols, G.; Sjerps, M.J.

    2014-01-01

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by

  18. Gas chromatographic method fr determination of carbon in metallic uranium

    International Nuclear Information System (INIS)

    Nikol'skij, V.A.; Markov, V.K.; Evseeva, T.I.; Cherstvenkova, E.P.

    1983-01-01

    Gas chromatographic device to determine carbon in metal uranium is developed. Burnout unite, permitting to load in the burnout tube simultaneously quite a few (up to 20) weight amounts of materials to be burned is a characteristic feature of the device. As a result amendments for control experiment and determination limit are decreased. The time of a single determination is also reduced. Conditions of carbon burn out from metal uranium are studied and temperature and time of complete extraction of carbon in the form of dioxide from weight amount into gaseous phase are established

  19. Gas chromatographic isolation technique for compound-specific radiocarbon analysis

    International Nuclear Information System (INIS)

    Uchida, M.; Kumamoto, Y.; Shibata, Y.; Yoneda, M.; Morita, M.; Kawamura, K.

    2002-01-01

    Full text: We present here a gas chromatographic isolation technique for the compound-specific radiocarbon analysis of biomarkers from the marine sediments. The biomarkers of fatty acids, hydrocarbon and sterols were isolated with enough amount for radiocarbon analysis using a preparative capillary gas chromatograph (PCGC) system. The PCGC systems used here is composed of an HP 6890 GC with FID, a cooled injection system (CIS, Gerstel, Germany), a zero-dead-volume effluent splitter, and a cryogenic preparative collection device (PFC, Gerstel). For AMS analysis, we need to separate and recover sufficient quantity of target individual compounds (>50 μgC). Yields of target compounds from C 14 n-alkanes to C 40 to C 30 n-alkanes and approximately that of 80% for higher molecular weights compounds more than C 30 n-alkanes. Compound specific radiocarbon analysis of organic compounds, as well as compound-specific stable isotope analysis, provide valuable information on the origins and carbon cycling in marine system. Above PCGC conditions, we applied compound-specific radiocarbon analysis to the marine sediments from western north Pacific, which showed the possibility of a useful chronology tool for estimating the age of sediment using organic matter in paleoceanographic study, in the area where enough amounts of planktonic foraminifera for radiocarbon analysis by accelerator mass spectrometry (AMS) are difficult to obtain due to dissolution of calcium carbonate. (author)

  20. Chromatographic assay of degradation products of tributyl phosphate

    International Nuclear Information System (INIS)

    Tripathi, S.C.; Ramanujam, A.; Nadkarni, M.N.; Rao, K.A.; Bandyopadhyay, C.

    1985-01-01

    Gas-liquid chromatography (GLC) and thin-layer chromatographic (TLC) procedures have been developed for the estimation of monobutyl phosphoric acid (H 2 MBP) and dibutyl phosphoric acid (HDBP) present in tributyl phosphate (TBP). Less than one microgram of H 2 MBP and HDBP is visually detected on TLC plate made of silicagel-cellulose (1:1). HDBP as separated by TLC has been quantitatively estimated in the range of 40-260 μg using an indirect spectrophotometric method. GLC method using 10 percent (W/W) XE-60 column can be effectively used for the simultaneous determination of 0.25 percent W/V H 2 MBP and HDBP present in 30 percent TBP-n-dodecane. The sensitivity may be enhanced 100 fold by careful column conditioning and judicious control of operational parameters. (author)

  1. Application of Carbon Nanotubes in Chiral and Achiral Separations of Pharmaceuticals, Biologics and Chemicals

    Directory of Open Access Journals (Sweden)

    Ayman L. Hemasa

    2017-07-01

    Full Text Available Carbon nanotubes (CNTs possess unique mechanical, physical, electrical and absorbability properties coupled with their nanometer dimensional scale that renders them extremely valuable for applications in many fields including nanotechnology and chromatographic separation. The aim of this review is to provide an updated overview about the applications of CNTs in chiral and achiral separations of pharmaceuticals, biologics and chemicals. Chiral single-walled carbon nanotubes (SWCNTs and multi-walled carbon nanotubes (MWCNTs have been directly applied for the enantioseparation of pharmaceuticals and biologicals by using them as stationary or pseudostationary phases in chromatographic separation techniques such as high-performance liquid chromatography (HPLC, capillary electrophoresis (CE and gas chromatography (GC. Achiral MWCNTs have been used for achiral separations as efficient sorbent objects in solid-phase extraction techniques of biochemicals and drugs. Achiral SWCNTs have been applied in achiral separation of biological samples. Achiral SWCNTs and MWCNTs have been also successfully used to separate achiral mixtures of pharmaceuticals and chemicals. Collectively, functionalized CNTs have been indirectly applied in separation science by enhancing the enantioseparation of different chiral selectors whereas non-functionalized CNTs have shown efficient capabilities for chiral separations by using techniques such as encapsulation or immobilization in polymer monolithic columns.

  2. Extraction chromatographic method of uranium(VI) with high molecular mass amine (ALIQUAT - 336)

    International Nuclear Information System (INIS)

    Roy, Uday Sankar; Dutta, Keshab Kumar

    1999-01-01

    A selective method has been developed for reversed phase extraction chromatographic studies of uranium(VI) with Aliquat - 336 (liquid anion exchanger) coated on silica gel as stationary phase. Quantitative extraction of uranium has been achieved in HCl - medium from 1.25(M)-4(M). The effect of different acids with various concentrations stripping agents, flow rate on extraction and elution have been investigated. The exchange capacity of the prepared exchanger has been determined. Uranium(VI) has been separated quantitatively from Th, Ce, Zr, Pb, Ga, Hg, Fe, La, Pr, Nd, Sm and Cr from a binary mixture by controlling the extraction and elution conditions. The separation of U(VI) from ternary and quarternary mixtures of various metal ions has also been achieved. (author)

  3. Direct coupling of a liquid chromatograph to a continuous flow hydrogen nuclear magnetic resonance detector for analysis of petroleum and synthetic fuels

    International Nuclear Information System (INIS)

    Haw, J.F.; Glass, T.E.; Hausler, D.W.; Motell, E.; Dorn, H.C.

    1980-01-01

    Initial results obtained for a flow 1 H nuclear magnetic resonance (NMR) detector directly coupled to a liquid chromatography unit are described. Results achieved for a model mixture and several jet fuel samples are discussed. Chromatographic separation of alkanes, alkylbenzenes, and substituted naphthalenes present in the jet fuel samples are easily identified with the 1 H NMR detector. Results with our present flow 1 H NMR insert indicate that 5-Hz linewidths are readily obtainable for typical chromatographic flow rates. The limitations and advantages of this liquid chromatography detector are compared with more commonly employed detectors (e.g., refractive index detectors). 11 figures

  4. An improved high-performance liquid chromatographic method for simultaneous determination of tocopherols, tocotrienols and γ-oryzanol in rice.

    Science.gov (United States)

    Huang, Shao-Hua; Ng, Lean-Teik

    2011-07-22

    An improved normal phase high performance liquid chromatographic (NP-HPLC) method was developed for simultaneous quantification of eight vitamin E isomers (α-, β-, γ- and δ-tocopherols and α-, β-, γ- and δ-tocotrienols) and γ-oryzanol in rice. A complete separation of all compounds was achieved within 25 min using an Inertsil CN-3, SIL-100A 5 μM (4.6 mm × 250 mm) column and an isocratic elution system of hexane/isopropanol/ethylacetate/acetic acid (97.6:0.8:0.8:0.8, v/v/v/v) at a flow rate varying from 0.7 to 1.5 mL min(-1). A linear correlation coefficient (r(2)>0.99) and high reproducibility were obtained at concentrations ranging 0.05-10 μg mL(-1) for vitamin E isomers and 0.5-500 μg mL(-1) for γ-oryzanol. This method proved to be rapid, accurate and reproducible. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Industrial Membrane Filtration and Short-bed Fractal Separation Systems for Separating Monomers from Heterogeneous Plant Material

    Energy Technology Data Exchange (ETDEWEB)

    Kearney, M; Kochergin, V; Hess, R; Foust, T; Herbst, R; Mann, N

    2005-03-31

    Large-scale displacement of petroleum will come from low-cost cellulosic feedstocks such as straw and corn stover crop residues. This project has taken a step toward making this projection a reality by reducing capital and energy costs, the two largest cost factors associated with converting cellulosic biomass to chemicals and fuels. The technology exists for using acid or enzyme hydrolysis processes to convert biomass feedstock (i.e., waste cellulose such as straw, corn stover, and wood) into their base monomeric sugar building blocks, which can, in turn, be processed into chemicals and fuels using a number of innovative fermentation technologies. However, while these processes are technically possible, practical and economic barriers make these processes only marginally feasible or not feasible at all. These barriers are due in part to the complexity and large fixed and recurring capital costs of unit operations including filtration, chromatographic separation, and ion exchange. This project was designed to help remove these barriers by developing and implementing new purification and separation technologies that will reduce the capital costs of the purification and chromatographic separation units by 50% to 70%. The technologies fundamental to these improvements are: (a) highly efficient clarification and purification systems that use screening and membrane filtration to eliminate suspended solids and colloidal material from feed streams and (b) fractal technology based chromatographic separation and ion exchange systems that can substitute for conventional systems but at much smaller size and cost. A non-hazardous ''raw sugar beet juice'' stream (75 to 100 gal/min) was used for prototype testing of these technologies. This raw beet juice stream from the Amalgamated Sugar LLC plant in Twin Falls, Idaho contained abrasive materials and membrane foulants. Its characteristics were representative of an industrial-scale heterogeneous plant extract

  6. Separation of zirconium and hafnium using paper distribution chromatography

    International Nuclear Information System (INIS)

    Lebedeva, G.G.; Viktorova, M.E.

    1981-01-01

    A method is suggested of chromatographic separation of zirconium and hafnium in a CCl 4 -tributyl phosphate system (1:9) containing KCl as a salting-out agent in 5 M HNO 3 at 28-30 deg C. Zr and Hf are deterfmined in articiial mixtures under optimal chromatography conditions using visual colorimetry [ru

  7. Different Spectrophotometric and Chromatographic Methods for Determination of Mepivacaine and Its Toxic Impurity.

    Science.gov (United States)

    Abdelwahab, Nada S; Fared, Nehal F; Elagawany, Mohamed; Abdelmomen, Esraa H

    2017-09-01

    Stability-indicating spectrophotometric, TLC-densitometric, and ultra-performance LC (UPLC) methods were developed for the determination of mepivacaine HCl (MEP) in the presence of its toxic impurity, 2,6-dimethylanaline (DMA). Different spectrophotometric methods were developed for the determination of MEP and DMA. In a dual-wavelength method combined with direct spectrophotometric measurement, the absorbance difference between 221.4 and 240 nm was used for MEP measurements, whereas the absorbance at 283 nm was used for measuring DMA in the binary mixture. In the second-derivative method, amplitudes at 272.2 and 232.6 nm were recorded and used for the determination of MEP and DMA, respectively. The developed TLC-densitometric method depended on chromatographic separation using silica gel 60 F254 TLC plates as a stationary phase and methanol-water-acetic acid (9 + 1 + 0.1, v/v/v) as a developing system, with UV scanning at 230 nm. The developed UPLC method depended on separation using a C18 column (250 × 4.6 mm id, 5 μm particle size) as a stationary phase and acetonitrile-water (40 + 60, v/v; pH 4 with phosphoric acid) as a mobile phase at a flow rate of 0.4 mL/min, with UV detection at 215 nm. The chromatographic run time was approximately 1 min. The proposed methods were validated with respect to International Conference on Harmonization guidelines regarding precision, accuracy, ruggedness, robustness, and specificity.

  8. Statistical Assessment of Solvent Mixture Models Used for Separation of Biological Active Compounds

    Directory of Open Access Journals (Sweden)

    Lorentz Jäntschi

    2008-08-01

    Full Text Available Two mathematical models with seven and six parameters have been created for use as methods for identification of the optimum mobile phase in chromatographic separations. A series of chromatographic response functions were proposed and implemented in order to assess and validate the models. The assessment was performed on a set of androstane isomers. Pearson, Spearman, Kendall tau-a,b,c and Goodman-Kruskal correlation coefficients were used in order to identify and to quantify the link and its nature (quantitative, categorical, semi-quantitative, both quantitative and categorical between experimental values and the values estimated by the mathematical models. The study revealed that the six parameter model is valid and reliable for five chromatographic response factors (retardation factor, retardation factor ordered ascending by the chromatographic peak, resolution of pairs of compound, resolution matrix of successive chromatographic peaks, and quality factor. Furthermore, the model could be used as an instrument in analysis of the quality of experimental data. The results obtained by applying the model with six parameters for deviations of rank sums suggest that the data of the experiment no. 8 are questionable.

  9. π-Extended triptycene-based material for capillary gas chromatographic separations.

    Science.gov (United States)

    Yang, Yinhui; Wang, Qinsi; Qi, Meiling; Huang, Xuebin

    2017-10-02

    Triptycene-based materials feature favorable physicochemical properties and unique molecular recognition ability that offer good potential as stationary phases for capillary gas chromatography (GC). Herein, we report the investigation of utilizing a π-extended triptycene material (denoted as TQPP) for GC separations. As a result, the TQPP capillary column exhibited high column efficiency of 4030 plates m -1 and high-resolution performance for a wide range of analytes, especially structural and positional isomers. Interestingly, the TQPP stationary phase showed unique shape selectivity for alkanes isomers and preferential retention for analytes with halogen atoms and H-bonding nature mainly through their halogen-bonding and H-bonding interactions. In addition, the TQPP column had good repeatability and reproducibility with the RSD values of 0.02-0.34% for run-to-run, 0.09-0.80% for day-to-day and 1.4-5.2% for column-to-column, respectively, and favorable thermal stability up to 280 °C. This work demonstrates the promising future of triptycene-based materials as a new class of stationary phases for GC separations. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Evaluation of pesticide adsorption in gas chromatographic injector and column

    Directory of Open Access Journals (Sweden)

    Gevany Paulino de Pinho

    2012-01-01

    Full Text Available Components in complex matrices can cause variations in chromatographic response during analysis of pesticides by gas chromatography. These variations are related to the competition between analytes and matrix components for adsorption sites in the chromatographic system. The capacity of the pesticides chlorpyrifos and deltamethrin to be adsorbed in the injector and chromatographic column was evaluated by constructing three isotherms and changing the column heating rate to 10 and 30 ºC min-1. By using ANCOVA to compare the slope of calibration graphs, results showed that the higher the injector temperature (310 ºC the lower the pesticide adsorption. Also, deltamethrin influenced the adsorption of chlorpyrifos on the column chromatographic.

  11. Polymethacrylate-based monoliths as stationary phases for separation of biopolymers and immobilization of enzymes.

    Science.gov (United States)

    Martinović, Tamara; Josić, Djuro

    2017-11-01

    The experiences in the production and application of polymethacrylate-based monolithic supports, since their development almost thirty years ago, are presented. The main driving force for the development of new chromatographic supports was the necessity for the isolation and separation of physiologically active biopolymers and their use for therapeutic purposes. For this sake, a development of a method for fast separation, preventing denaturation and preserving their biological activity was necessary. Development of polysaccharide-based supports, followed by the introduction of polymer-based chromatographic media, is shortly described. This development was followed by the advances in monolithic media that are now used for both large- and small-scale separation of biopolymers and nanoparticles. Finally, a short overview is given about the applications of monoliths for sample displacement chromatography, resulting in isolation of physiologically active biomolecules, such as proteins, protein complexes, and nucleic acid, as well as high-throughput sample preparation for proteomic investigations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Group separation of organohalogenated contaminants by GCxGC

    Energy Technology Data Exchange (ETDEWEB)

    Korytar, P.; Leonards, P.; Boer, J. de [Netherlands Institute for Fisheries Research, IJmuiden (Netherlands); Parera, J. [Barcelona Univ. (Spain); Brinkman, U. [Vrije Univ., Amsterdam (Netherlands)

    2004-09-15

    The congener specific analysis of organohalogenated compounds is challenging, because of a large number of possibly interfering compounds not only within the compound class but also from congeners of other compound classes. Therefore, analytical procedures usually include complicated and time-consuming multi-step sample pre-treatment and/or selective detection (e.g. HRMS, MS/MS) in the consequent gas chromatographic analysis, what makes the procedures laborious and expensive. One way how to improve the situation would be to considerably increase the separation efficiency of the gas chromatographic analysis by replacing conventional GC by so-called comprehensive two-dimensional gas chromatography (GC x GC). In GC x GC two independent separations are applied to an entire sample which effects a considerably enhanced overall resolution and also, because of the analyte refocusing during modulation, an improved analyte detectability. One further aspect which makes GC x GC especially attractive is the ordered structure of the two-dimensional chromatograms, which is observed when mixtures of related compounds, homologues or congeners are analysed. One good example are the bands of alkanes, naphthenes and aromatics present in 2D chromatogram when petrochemical samples are analysed. The ordered structure was reported also within the compound class of some organohalogenated contaminants, more precisely, of polychlorinated biphenyls and toxaphenes (ordering to number of chlorine atoms on the skeleton). However, to date, no study of separation among the different compound classes has been reported. In the present paper, this topic will be studied for the most common contaminants. While the principle aim is the group type separation, some attention will be devoted also to within the class separation (e.g., for polychlorinated diphenylethers and polychlorinated alkanes).

  13. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis

    OpenAIRE

    Kshirsagar, Parthraj R.; Hegde, Harsha; Pai, Sandeep R.

    2016-01-01

    Background and Aim: This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. Materials and Methods: One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at ?4?C. Results: Contaminant peak was detected in methanol stored in polypropylene m...

  14. Gas-Chromatographic Determination Of Water In Freon PCA

    Science.gov (United States)

    Melton, Donald M.

    1994-01-01

    Gas-chromatographic apparatus measures small concentrations of water in specimens of Freon PCA. Testing by use of apparatus faster and provides greater protection against accidental contamination of specimens by water in testing environment. Automated for unattended operation. Also used to measure water contents of materials, other than Freon PCA. Innovation extended to development of purgeable sampling accessory for gas chromatographs.

  15. Novel reprocessing methods with nuclide separation for volume reduction of high level radioactive waste

    International Nuclear Information System (INIS)

    Suzuki, Tatsuya

    2015-01-01

    We have proposed the reprocessing system with nuclide separation processes based on the chromatographic technique in the hydrochloric acid solution system. Our proposing system consists of the dissolution process, the reprocessing process, the MA separation process, and nuclide separation processes. In our proposing processes, the pyridine resin is used as a main separation media. We expect that our proposing will contribute to that volume reduction of high level radioactive waste by combining the transmutation techniques, usage of valuable elements, and so on. (author)

  16. Human neuroimaging studies on the hippocampal CA3 region – integrating evidence for pattern separation and completion

    Directory of Open Access Journals (Sweden)

    Lorena eDeuker

    2014-03-01

    Full Text Available Human functional magnetic imaging (fMRI studies have long investigated the hippocampus without differentiating between its subfields, even though theoretical models and rodent studies suggest that subfields support different and potentially even opposite functions. The CA3 region of the hippocampus has been ascribed a pivotal role both in initially forming associations during encoding and in reconstructing a memory representation based on partial cues during retrieval. These functions have been related to pattern separation and pattern completion, respectively. In recent years, studies using high-resolution fMRI in humans have begun to separate different hippocampal subregions and identify the role of the CA3 subregion relative to the other subregions. However, some of these findings have been inconsistent with theoretical models and findings from electrophysiology. In this review, we describe selected recent studies and highlight how their results might help to define different processes and functions that are presumably carried out by the CA3 region, in particular regarding the seemingly opposing functions of pattern separation and pattern completion. We also describe how these subfield-specific processes are related to behavioral, functional and structural alterations in patients with mild cognitive impairment and Alzheimer’s disease. We conclude with discussing limitations of functional imaging and briefly outline possible future developments of the field.

  17. Ionic Liquid-Liquid Chromatography: A New General Purpose Separation Methodology.

    Science.gov (United States)

    Brown, Leslie; Earle, Martyn J; Gîlea, Manuela A; Plechkova, Natalia V; Seddon, Kenneth R

    2017-08-10

    Ionic liquids can form biphasic solvent systems with many organic solvents and water, and these solvent systems can be used in liquid-liquid separations and countercurrent chromatography. The wide range of ionic liquids that can by synthesised, with specifically tailored properties, represents a new philosophy for the separation of organic, inorganic and bio-based materials. A customised countercurrent chromatograph has been designed and constructed specifically to allow the more viscous character of ionic liquid-based solvent systems to be used in a wide variety of separations (including transition metal salts, arenes, alkenes, alkanes, bio-oils and sugars).

  18. Application of ionic liquids in liquid chromatography and electrodriven separation.

    Science.gov (United States)

    Huang, Yi; Yao, Shun; Song, Hang

    2013-08-01

    Ionic liquids (ILs) are salts in the liquid state at ambient temperature, which are nonvolatile, nonflammable with high thermal stability and dissolve easily for a wide range of inorganic and organic materials. As a kind of potential green solvent, they show high efficiency and selectivity in the field of separation research, especially in instrumental analysis. Thus far, ILs have been successfully applied by many related researchers in high-performance liquid chromatography and capillary electrophoresis as chromatographic stationary phases, mobile phase additives or electroosmotic flow modifiers. This paper provides a detailed review of these applications in the study of natural products, foods, drugs and other fine chemicals. Furthermore, the prospects of ILs in liquid chromatographic and electrodriven techniques are discussed.

  19. Separation of organic and inorganic arsenic species by HPLC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Londesborough, S. [University of Helsinki, Department of Chemistry (Finland); Mattusch, J.; Wennrich, R. [UFZ-Centre for Environmental Research Leipzig-Halle, Department of Analytical Chemistry, Leipzig (Germany)

    1999-03-01

    The HPLC separation of eight anionic, cationic or neutral arsenic species (arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, arsenocholine, trimethylarsine oxide and tetramethylarsonium ion) on a high-capacity, anion-exchange column (Ion Pac AS 7, Dionex) was studied. The separation was performed during one run with a nitric acid gradient ranging from pH 4-1.3. The influence of sodium dodecyl sulfate (SDS), sodium octyl sulfate (SOS) and 1,2-benzenedisulfonic acid (BDSA) as ion pairing eluent modifiers was investigated. In addition the effect of elevated temperatures (30 to 40 C) was studied. The best results were obtained at room temperature of 20 C with 0.05 mM benzenedisulfonic acid as the eluent modifier. The chromatograph was connected to an ICP-MS via a cross-flow nebulizer. Detection limits obtained with the optimized chromatographic separation were 0.16-0.60 {mu}g As L{sup -1} for different species. The proposed speciation method was applied to the determination of arsenic species in the DORM-2 reference material (Dogfish Muscle) and in aqueous extracts of mushrooms collected on arsenic contaminated ground. (orig.) With 7 figs., 4 tabs., 17 refs.

  20. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    Science.gov (United States)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  1. Imbalanced pattern completion vs. separation in cognitive disease: network simulations of synaptic pathologies predict a personalized therapeutics strategy

    Directory of Open Access Journals (Sweden)

    Hanson Jesse E

    2010-08-01

    Full Text Available Abstract Background Diverse Mouse genetic models of neurodevelopmental, neuropsychiatric, and neurodegenerative causes of impaired cognition exhibit at least four convergent points of synaptic malfunction: 1 Strength of long-term potentiation (LTP, 2 Strength of long-term depression (LTD, 3 Relative inhibition levels (Inhibition, and 4 Excitatory connectivity levels (Connectivity. Results To test the hypothesis that pathological increases or decreases in these synaptic properties could underlie imbalances at the level of basic neural network function, we explored each type of malfunction in a simulation of autoassociative memory. These network simulations revealed that one impact of impairments or excesses in each of these synaptic properties is to shift the trade-off between pattern separation and pattern completion performance during memory storage and recall. Each type of synaptic pathology either pushed the network balance towards intolerable error in pattern separation or intolerable error in pattern completion. Imbalances caused by pathological impairments or excesses in LTP, LTD, inhibition, or connectivity, could all be exacerbated, or rescued, by the simultaneous modulation of any of the other three synaptic properties. Conclusions Because appropriate modulation of any of the synaptic properties could help re-balance network function, regardless of the origins of the imbalance, we propose a new strategy of personalized cognitive therapeutics guided by assay of pattern completion vs. pattern separation function. Simulated examples and testable predictions of this theorized approach to cognitive therapeutics are presented.

  2. A novel two-dimensional liquid chromatographic system for the online toxicity prediction of pharmaceuticals and related substances

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jian; Xu, Li [Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan 430030 (China); Shi, Zhi-guo, E-mail: shizg@whu.edu.cn [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu, Min [Hubei Instrument for Food and Drug Control, Wuhan (China)

    2015-08-15

    Highlights: • A novel two-dimensional liquid chromatographic system was developed. • The 1st dimension was ODS to separate components in the sample. • The 2nd dimension was biopartitioning micellar chromatography to predict toxicity. • The system was used to screen toxicity of pharmaceuticals and related substances. • It was promising for fast online toxicity screening of complex sample in one step. - Abstract: In this study, a novel two-dimensional liquid chromatographic (2D-LC) system was developed for simultaneous separation and toxicity prediction of pharmaceutical and its related substances. A conventional ODS column was used on the 1st-D to separate the sample; while, bio-partitioning micellar chromatography served as the 2nd-D to predict toxicity of the components. The established system was tested for the toxicity of ibuprofen and its impurities with known toxicity. With only one injection, ibuprofen and its impurities were separated on the 1st-D; and LC50 values of individual impurity were obtained based on the quantitative retention–activity relationships, which agreed well with the reported data. Furthermore, LC50 values of photolysis transformation products (TPs) of carprofen, ketoprofen and diclofenac acid (as unknown compounds) were screened in this 2D-LC system, which could be an indicator of the toxicity of these TPs and was meaningful for the environmental monitoring and drinking water treatment. The established 2D-LC system was cost-effective, time-saving and reliable, and was promising for fast online screening of toxicity of known and unknown analytes in the complex sample in a single step. It may find applications in environment, pharmaceutical and food, etc.

  3. A novel two-dimensional liquid chromatographic system for the online toxicity prediction of pharmaceuticals and related substances

    International Nuclear Information System (INIS)

    Li, Jian; Xu, Li; Shi, Zhi-guo; Hu, Min

    2015-01-01

    Highlights: • A novel two-dimensional liquid chromatographic system was developed. • The 1st dimension was ODS to separate components in the sample. • The 2nd dimension was biopartitioning micellar chromatography to predict toxicity. • The system was used to screen toxicity of pharmaceuticals and related substances. • It was promising for fast online toxicity screening of complex sample in one step. - Abstract: In this study, a novel two-dimensional liquid chromatographic (2D-LC) system was developed for simultaneous separation and toxicity prediction of pharmaceutical and its related substances. A conventional ODS column was used on the 1st-D to separate the sample; while, bio-partitioning micellar chromatography served as the 2nd-D to predict toxicity of the components. The established system was tested for the toxicity of ibuprofen and its impurities with known toxicity. With only one injection, ibuprofen and its impurities were separated on the 1st-D; and LC50 values of individual impurity were obtained based on the quantitative retention–activity relationships, which agreed well with the reported data. Furthermore, LC50 values of photolysis transformation products (TPs) of carprofen, ketoprofen and diclofenac acid (as unknown compounds) were screened in this 2D-LC system, which could be an indicator of the toxicity of these TPs and was meaningful for the environmental monitoring and drinking water treatment. The established 2D-LC system was cost-effective, time-saving and reliable, and was promising for fast online screening of toxicity of known and unknown analytes in the complex sample in a single step. It may find applications in environment, pharmaceutical and food, etc

  4. Flame-photometric determination of boron in alloys with chromatographic separation

    International Nuclear Information System (INIS)

    Telegin, G.F.; Popandopulo, Yu.I.; Grazhuiene, S.S.

    1983-01-01

    A study was made on the possibility of using flame-photometric method for boron determination in iron base alloys. The method of extraction chromatography was used for boron separation from iron. It is possible to reliably determine boron in Fesub(x)Bsub(100-x) alloys only at a concentration ratio of iron to boron <=0.2. The technique for determination of boron in Fesub(x)Bsub(100-x) alloys was developed on the base of the conducted investigation

  5. Flame-photometric determination of boron in alloys with chromatographic separation

    Energy Technology Data Exchange (ETDEWEB)

    Telegin, G.F.; Popandopulo, Yu.I.; Grazhuiene, S.S. (AN SSSR, Chernogolovka. Inst. Fiziki Tverdogo Tela)

    1983-01-01

    A study was made on the possibility of using flame-photometric method for boron determination in iron base alloys. The method of extraction chromatography was used for boron separation from iron. It is possible to reliably determine boron in Fesub(x)Bsub(100-x) alloys only at a concentration ratio of iron to boron <=0.2. The technique for determination of boron in Fesub(x)Bsub(100-x) alloys was developed on the base of the conducted investigation.

  6. Current Developments in Electrophoretic and Chromatographic Separation Methods on Microfabricated Devices

    DEFF Research Database (Denmark)

    Kutter, Jörg Peter

    2000-01-01

    Microchip-based separation techniques are essential elements in the development of fully integrated micro-total analysis systems, which are envisioned to become powerful instruments for obtaining and assessing analytical data in research, industry, and everyday life. This article's goal is to give...

  7. Chromatographic resolution of closely related species in pharmaceutical chemistry: dehalogenation impurities and mixtures of halogen isomers.

    Science.gov (United States)

    Regalado, Erik L; Zhuang, Ping; Chen, Yadan; Makarov, Alexey A; Schafer, Wes A; McGachy, Neil; Welch, Christopher J

    2014-01-07

    In recent years, the use of halogen-containing molecules has proliferated in the pharmaceutical industry, where the incorporation of halogens, especially fluorine, has become vitally important for blocking metabolism and enhancing the biological activity of pharmaceuticals. The chromatographic separation of halogen-containing pharmaceuticals from associated isomers or dehalogenation impurities can sometimes be quite difficult. In an attempt to identify the best current tools available for addressing this important problem, a survey of the suitability of four chromatographic method development platforms (ultra high-performance liquid chromatography (UHPLC), core shell HPLC, achiral supercritical fluid chromatography (SFC) and chiral SFC) for separating closely related mixtures of halogen-containing pharmaceuticals and their dehalogenated isosteres is described. Of the 132 column and mobile phase combinations examined for each mixture, a small subset of conditions were found to afford the best overall performance, with a single UHPLC method (2.1 × 50 mm, 1.9 μm Hypersil Gold PFP, acetonitrile/methanol based aqueous eluents containing either phosphoric or perchloric acid with 150 mM sodium perchlorate) affording excellent separation for all samples. Similarly, a survey of several families of closely related halogen-containing small molecules representing the diversity of impurities that can sometimes be found in purchased starting materials for synthesis revealed chiral SFC (Chiralcel OJ-3 and Chiralpak IB, isopropanol or ethanol with 25 mM isobutylamine/carbon dioxide) as well as the UHPLC (2.1 × 50 mm, 1.8 μm ZORBAX RRHD Eclipse Plus C18 and the Gold PFP, acetonitrile/methanol based aqueous eluents containing phosphoric acid) as preferred methods.

  8. Simultaneous column chromatographic extraction and purification of abscisic acid in peanut plants for direct HPLC analysis.

    Science.gov (United States)

    Zhang, Ya-Wen; Fan, Wei-Wei; Li, Hui; Ni, He; Han, Han-Bing; Li, Hai-Hang

    2015-10-01

    Abscisic acid (ABA), a universal signaling molecule, plays important roles in regulating plant growth, development and stress responses. The low contents and complex components in plants make it difficult to be accurately analyzed. A novel one-step sample preparation method for ABA in plants was developed. Fresh peanut (Arachis hypogaea) plant materials were fixed by oven-drying, microwave drying, boiling or Carnoy's fixative, and loaded onto a mini-preparing column. After washed the impurities, ABA was eluted with a small amount of solvent. ABA in plant materials was completely extracted and purified in 2mL solution and directly analyzed by HPLC, with a 99.3% recovery rate. Multiple samples can be simultaneously prepared. Analyses using this method indicated that the endogenous ABA in oven-dried peanut leaves increased 20.2-fold from 1.01 to 20.37μgg(-1) dry weight within 12h and then decreased in 30% polyethylene glycol 6000 treated plants, and increased 3.34-fold from 0.85 to 2.84μgg(-1) dry weight in 5 days and then decreased in soil drought treated plants. The method combined the column chromatographic extraction and solid-phase separation technologies in one step and can completely extracted plant endogenous ABA in a purified and highly concentrated form for direct HPLC analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Separation of metronidazole, its major metabolites and their conjugates using dynamically modified silica

    DEFF Research Database (Denmark)

    Thomsen, U. G.; Cornett, Claus; Tjornelund, J.

    1995-01-01

    -performance liquid chromatographic (HPLC) system for the simultaneous determination of metronidazole, its major metabolites and their glucuronic acid conjugates in biological fluids. The separation is performed using bare silica dynamically modified with N-cetyl-N,N,N-trimethylammonium bromide contained...

  10. Evaluation of highly polar ionic liquid gas chromatographic column for the determination of the fatty acids in milk fat.

    Science.gov (United States)

    Delmonte, Pierluigi; Fardin-Kia, Ali Reza; Kramer, John K G; Mossoba, Magdi M; Sidisky, Len; Tyburczy, Cynthia; Rader, Jeanne I

    2012-04-13

    The SLB-IL111, a new ionic liquid capillary column for gas chromatography available from Supelco Inc., was recently shown to provide enhanced separation of unsaturated geometric and positional isomers of fatty acid (FAs) when it was compared to cyanopropylsiloxane (CPS) columns currently recommended for the analysis of fatty acid methyl esters (FAMEs). A 200 m SLB-IL111 capillary column, operated under a combined temperature and eluent flow gradient, was successfully used to resolve most of the FAs contained in milk fat in a single 80 min chromatographic separation. The selected chromatographic conditions provided a balanced, simultaneous separation of short-chain (from 4:0), long-chain polyunsaturated fatty acids (PUFAs), and most of the unsaturated FA positional/geometric isomers contained in milk fat. Among the monounsaturated fatty acids (MUFAs), these conditions separated t11-18:1 and t10-18:1 FAs, the two most abundant trans fatty acids (t-FA) contained in most dairy products. These t-FAs reportedly have different biological activities. The conjugated linoleic acid (CLA) isomers commonly found in dairy products were separated from each other, including t7,c9-18:2 from c9,t11-18:2, which eliminated the need for their complementary silver ion HPLC analysis. The application of the SLB-IL111 column provided a complementary elution profile of FAMEs to those obtained by CPS columns, allowing for a more comprehensive FA analysis of total milk fat. The FAMEs were identified by the use of available reference materials, previously synthesized and characterized reference mixtures, and prior separations of the milk fat FAMEs by silver ion chromatography based on the number/geometry of double bonds. Published by Elsevier B.V.

  11. Neptunium separation in trace levels from uranium solutions by extraction chromatography

    International Nuclear Information System (INIS)

    Cotrim, M.B.; Matsuda, H.T.

    1994-01-01

    Neptunium and uranium behavior in extraction chromatograph system, aiming the separation of micro quantities of neptunium from uranyl solutions is described. Tri-n-octylamine (TOA), Tri-n-butylphosphate (TBP) as stationary phase, alumine, Voltalef UF-300 as support material were verified. The impregnation conditions as well as the best stationary phase/support material ratio were established. TBP/alumine, TBP/Voltalef and TOA/alumine system were selected to uranium and neptunium separation studies. (author) . 12 refs., 03 tabs., 03 figs

  12. Chromatographic determination of clopidogrel bisulfate; detection and quantification of counterfeit Plavix® tablets

    Directory of Open Access Journals (Sweden)

    Mona E. ElTantawy

    2014-06-01

    Full Text Available Counterfeiting of pharmaceutical products is a global problem. Upon using quality-ensuring methods of international pharmacopoeias, additional impurities and the low content of the active pharmaceutical ingredients were detected. In this paper, two chromatographic HPLC and TLC-densitometric methods were proposed as fast and reliable methods for detection and quantitation of counterfeit Plavix® tablets. These tablets were chemically counterfeited by aspirin, its degradate salicylic acid and metronidazole which were separated, besides the active ingredient clopidogrel bisulfate, by the proposed methods. Also, counterfeit was in packaging, strips and tablets’ color and these could be seen by visual inspection compared to original drug. The proposed methods can easily differentiate genuine from counterfeited tablets without need of prior separation. The proposed methods were validated according to ICH guidelines and applied to eleven batches, also were compared statistically with the reported one.

  13. Comparison of Miniaturized and Conventional Asymmetrical Flow Field-Flow Fractionation (AF4 Channels for Nanoparticle Separations

    Directory of Open Access Journals (Sweden)

    Zengchao You

    2017-03-01

    Full Text Available The performance of a miniaturized channel for the separation of polymer and metal nanoparticles (NP using Asymmetrical Flow Field-Flow Fractionation (AF4 was investigated and compared with a conventional AF4 system. To develop standard separation methods, experimental parameters like cross flow, gradient profile and injection time were varied and optimized. Corresponding chromatographic parameters were calculated and compared. Our results indicate that the chromatographic resolution in the miniaturized channel is lower, whereas significantly shorter analyses time and less solvent consumption were obtained. Moreover, the limit of detection (LOD and limit of quantification (LOQ obtained from hyphenation with a UV-detector are obviously lower than in a conventional channel, which makes the miniaturized channel interesting for trace analysis.

  14. Liquid chromatographic determination with fluorescence detection of B6 vitamers and riboflavin in milk and pharmaceuticals

    International Nuclear Information System (INIS)

    Gatti, R.; Gioia, M.G.

    2005-01-01

    A simple, reliable and selective high performance liquid chromatographic method with fluorescence detection at different programmed wavelengths has been developed for the simultaneous analysis of B 6 vitamers (pyridoxal 5'-phosphate, 4-pyridoxic acid, pyridoxal, pyridoxine and pyridoxamine) and Vitamin B 2 in commercial vitaminized milk and in woman milk. The chromatographic separations were performed on a reversed phase octyl column by using a mobile phase consisting of sodium pentanesulfonate in 1% acetic acid-methanol-tetrahydrofuran under gradient elution conditions. The fluorescence intensity of pyridoxal 5'-phosphate was enhanced by post-column photochemical conversion, giving significantly different fluorescence spectra by a on-line photoreactor switched OFF and ON under irradiation at 254 nm. In addition, a simple and rapid method in isocratic conditions without the need of photochemical conversion was proposed for the analysis of Vitamin B 6 and Vitamin B 2 in pharmaceuticals. Linearity, precision, recovery, selectivity and sensitivity were found satisfactory for each analysed compound. Quantitation limits ranged from 26 to 240 fmol

  15. Form factors and complete spectrum of XXX antiperiodic higher spin chains by quantum separation of variables

    Energy Technology Data Exchange (ETDEWEB)

    Niccoli, G. [YITP, Stony Brook University, New York 11794-3840 (United States)

    2013-05-15

    The antiperiodic transfer matrices associated to higher spin representations of the rational 6-vertex Yang-Baxter algebra are analyzed by generalizing the approach introduced recently in the framework of Sklyanin's quantum separation of variables (SOV) for cyclic representations, spin-1/2 highest weight representations, and also for spin-1/2 representations of the 6-vertex reflection algebra. Such SOV approach allow us to derive exactly results which represent complicate tasks for more traditional methods based on Bethe ansatz and Baxter Q-operator. In particular, we both prove the completeness of the SOV characterization of the transfer matrix spectrum and its simplicity. Then, the derived characterization of local operators by Sklyanin's quantum separate variables and the expression of the scalar products of separate states by determinant formulae allow us to compute the form factors of the local spin operators by one determinant formulae similar to those of the scalar products.

  16. High-pressure liquid chromatographic determination of chlorphenesin carbamate and the beta-isomeric carbamate.

    Science.gov (United States)

    Beyer, W F

    1976-12-01

    A high-pressure liquid chromatographic assay was developed for the determination of chlorphenesin carbamate and its beta-isomeric carbamate. A single 4-mm i.d. X 30-cm column, prepacked with 10 micrometer fully porous silica gel particles, is used with 3% methanol in 50% water-saturated butyl chloride as the mobile phase. The procedure separates chlorphenesin carbamate from several possible impurities in addition to the beta-isomeric carbamate. The assay was applied to bulk drug and compressed tablets. The relative standard deviations for the assays of chlorphenesin carbamate and the beta-isomer are approximately 1 and 2%, respectively.

  17. Speciation of eight arsenic compounds in human urine by high performance liquid chromatography with inductively coupled plasma mass spectrometric detection using antimonate for internal chromatographic standardization

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pritzl, G.; Hansen, S. H.

    1993-01-01

    Four anionic and four cationic arsenic compounds in urine were separated by anion- and cation-exchange high-performance liquid chromatography and detected by inductively coupled plasma mass spectrometry (ICP-MS) at m/z 75. The species were the anions arsenite, arsenate, monomethylarsonate...... and dimethylarsinate and the cations arsenobetaine, trimethylarsine oxide, arsenocholine and the tetramethylarsonium ion. Hexahydroxyantimonate(III) was co-chromatographed with the arsenic anions but detected at m/z 121 and used as an internal standard for their qualitative analysis. Arsenite was prone to oxidation....... The argon chloride interference at m/z 75 was eliminated by chromatographic separation of the chloride present in the sample from the arsenic analytes. The ClO+ ion detected at m/z 51 and 53 was used to monitor the retention time of chloride in the anion-exchange system. The chloride eluted about 100 s...

  18. Separation of Ra/Ca by ion exchange

    International Nuclear Information System (INIS)

    Iturbe, J.L.; Jimenez R, M.; Flores M, J.

    1991-04-01

    The radium and the calcium belong to the same group in the periodic classification and as consequence both they present very similar chemical properties, that makes difficult its separation. Both elements are also frequently associate in the nature, the calcium is very abundant, the radium is not it and for that reason it is indispensable its separation to analyze to this last one. The alpha spectroscopy is very appropriate to analyze to the 226 Ra, however to achieve a good resolution of the spectra, the samples should contain small quantities of calcium. The purposes of this work were to know the chromatographic behavior of the alkaline-earthy cations: calcium, barium and radium and to apply these knowledge to the separation of the 226 Ra and its analysis by means of alpha spectroscopy. (Author)

  19. Optimisation of chromatographic resolution using objective functions including both time and spectral information.

    Science.gov (United States)

    Torres-Lapasió, J R; Pous-Torres, S; Ortiz-Bolsico, C; García-Alvarez-Coque, M C

    2015-01-16

    The optimisation of the resolution in high-performance liquid chromatography is traditionally performed attending only to the time information. However, even in the optimal conditions, some peak pairs may remain unresolved. Such incomplete resolution can be still accomplished by deconvolution, which can be carried out with more guarantees of success by including spectral information. In this work, two-way chromatographic objective functions (COFs) that incorporate both time and spectral information were tested, based on the peak purity (analyte peak fraction free of overlapping) and the multivariate selectivity (figure of merit derived from the net analyte signal) concepts. These COFs are sensitive to situations where the components that coelute in a mixture show some spectral differences. Therefore, they are useful to find out experimental conditions where the spectrochromatograms can be recovered by deconvolution. Two-way multivariate selectivity yielded the best performance and was applied to the separation using diode-array detection of a mixture of 25 phenolic compounds, which remained unresolved in the chromatographic order using linear and multi-linear gradients of acetonitrile-water. Peak deconvolution was carried out using the combination of orthogonal projection approach and alternating least squares. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Rapid planar chromatographic analysis of 25 water-soluble dyes used as food additives.

    Science.gov (United States)

    Morlock, Gertrud E; Oellig, Claudia

    2009-01-01

    A rapid planar chromatographic method for identification and quantification of 25 water-soluble dyes in food was developed. In a horizontal developing chamber, the chromatographic separation on silica gel 60F254 high-performance thin-layer chromatography plates took 12 min for 40 runs in parallel, using 8 mL ethyl acetate-methanol-water-acetic acid (65 + 23 + 11 + 1, v/v/v/v) mobile phase up to a migration distance of 50 mm. However, the total analysis time, inclusive of application and evaluation, took 60 min for 40 runs. Thus, the overall time/run can be calculated as 1.5 min with a solvent consumption of 200 microL. A sample throughput of 1000 runs/8 h day can be reached by switching between the working stations (application, development, and evaluation) in a 20 min interval, which triples the analysis throughput. Densitometry was performed by absorption measurement using the multiwavelength scan mode in the UV and visible ranges. Repeatabilities [relative standard deviation (RSD), 4 determinations] at the first or second calibration level showed precisions of mostly or = 0.9987) and RSD values ( or = 0.9996). If necessary for confirmation, online mass spectra were recorded within a minute.

  1. Improved separation with the intermittently pressed tubing of multilayer coil in type-I counter-current chromatography.

    Science.gov (United States)

    Yang, Yi; Yang, Jiao; Fang, Chen; Wang, Jihui; Gu, Dongyu; Tian, Jing; Ito, Yoichiro

    2018-05-25

    The intermittently pressed tubing was introduced in type-I counter-current chromatographic system as the separation column to improve the separation performance in the present study. The separations were performed with two different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW) and hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMW) using dipeptides and DNP-amino acids as test samples, respectively. The chromatographic performance was evaluated in terms of retention of the stationary phase (Sf), theoretical plate (N) and peak resolution (Rs). In general, the type-I planetary motion with the multilayer coil of non-modified standard tubing can yield the best separation at a low revolution speed of 200 rpm with lower flow rate. The present results with intermittently pressed tubing indicated that the performance was also optimal at the revolution speed of 200 rpm where the lower flow rate was more beneficial to retention of stationary phase and resolution. In the moderately hydrophobic two-phase solvent system composed of hexane-ethyl acetate-metanol-0.1 M hydrochloric acid (1:1:1:1, v/v), DNP-amino acids were separated with Rs at 1.67 and 1.47, respectively, with 12.66% of stationary phase retention at a flow rate of 0.25 ml/min. In the polar solvent system composed of 1-butanol-acetic acid-water (4:1:5, v/v), dipeptide samples were resolved with Rs at 2.18 and 18.75% of stationary phase retention at a flow rate of 0.25 ml/min. These results indicate that the present system substantially improves the separation efficiency of type-I counter-current chromatographic system. Published by Elsevier B.V.

  2. Mass spectrometric protein characterization in proteome analysis using GELoader tip micro-columns packed with various chromatographic material

    International Nuclear Information System (INIS)

    Larsen, M.R.

    2001-01-01

    In the early 90'ies mass spectrometry (MS) was introduced as a tool for identifying proteins in protein sequence databases. Since then it has become an integrated tool in protein characterization and is today routinely used to identify proteins separated by gel electrophoresis. A two-tiered mass spectrometric protein identification strategy has recently been proposed. In the first strategy peptide mass maps obtained from the protein of interest are compared with theoretically derived peptide mass maps from proteins in protein sequence databases. If the protein cannot be identified by this strategy, tandem mass spectrometric sequencing is used to generate enough sequence data to identify the protein in protein sequence databases or expressed sequence tag (EST) databases. However, the above strategies primarily identify a protein relatively to the DNA sequence, in which no information about e.g. post-translational modifications (PTMs) is stored. PTMs are known to modify the function, location, solubility and activity of proteins in the cell, and they are therefore very important for understanding living cells. More than 200 different PTMs are known, of which glycosylation, phosphorylation and proteolytic processing are the most common ones. Mass spectrometric analysis of PTMs on gel-separated proteins requires a higher amount of protein than for identification only. In addition, higher sequence coverage from the peptide mass maps or pre-purification of the modified peptides prior to MS analysis, is necessary for detection of putative modified peptides. In this study a multi-tiered strategy, in which GELoader tip micro-columns packed with increasingly more hydrophobic chromatographic material are used in combination with mass spectrometry, is described. The ultimate aim was to gain increased sequence coverage from peptide mixtures derived from gel-separated proteins, in order to locate modified peptides. Graphite powder is described as an alternative to traditional

  3. Gas chromatographic-mass spectrometric analysis of biomarkers related to folate and cobalamin status in human serum after dimercaptopropanesulfonate reduction and heptafluorobutyl chloroformate derivatization

    Czech Academy of Sciences Publication Activity Database

    Šimek, Petr; Hušek, Petr; Zahradníčková, Helena

    2008-01-01

    Roč. 80, č. 15 (2008), s. 5776-5782 ISSN 0003-2700 R&D Projects: GA ČR GA303/06/1674 Institutional research plan: CEZ:AV0Z50070508 Keywords : biomarkers * gas chromatographic * chloroformate derivatization Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 5.712, year: 2008

  4. Multiple chromatographic fingerprinting and its application to the quality control of herbal medicines

    International Nuclear Information System (INIS)

    Fan Xiaohui; Cheng Yiyu; Ye Zhengliang; Lin Ruichao; Qian Zhongzhi

    2006-01-01

    Recently, chromatographic fingerprinting has become one of the most powerful approaches to quality control of herbal medicines. However, the performance of reported chromatographic fingerprinting constructed by single chromatogram sometimes turns out to be inadequate for complex herbal medicines, such as multi-herb botanical drug products. In this study, multiple chromatographic fingerprinting, which consists of more than one chromatographic fingerprint and represents the whole characteristics of chemical constitutions of the complex medicine, is proposed as a potential strategy in this complicated case. As a typical example, a binary chromatographic fingerprinting of 'Danshen Dropping Pill' (DSDP), the best-sold traditional Chinese medicine in China, was developed. First, two HPLC fingerprints that, respectively, represent chemical characteristics of depsides and saponins of DSDP were developed, which were used to construct binary chromatographic fingerprints of DSDP. Moreover, the authentication and validation of the binary fingerprints were performed. Then, a data-level information fusion method was employed to capture the chemical information encoded in two chromatographic fingerprints. Based on the fusion results, the lot-to-lot consistency and frauds can be determined either using similarity measure or by chemometrics approach. The application of binary chromatographic fingerprinting to consistency assessment and frauds detection of DSDP clearly demonstrated that the proposed method was a powerful approach to quality control of complex herbal medicines

  5. High-pressure liquid chromatographic analysis of pramoxine hydrochloride in high lipoid aerosol foam dosage form.

    Science.gov (United States)

    Weinberger, R; Mann, B; Posluszny, J

    1980-04-01

    A rapid and quantitative method for the determination of pramoxine hydrochloride by high-pressure liquid chromatography is presented. The drug is extracted as the salt from a preparation with a high lipoid composition by partitioning it to the aqueous phase of an ether-methanol-water-acetic acid system. The extract is chromatographed on an octadecylsilane bonded packing with a methanol-water-acetic acid-methanesulfonic acid mobile phase. The time required for each separation is approximately 6 min. Analytical recoveries of 100.4 +/- 1.5% were obtained.

  6. Miniaturized chromatographic radiochemical procedure for 131I - MIBG

    International Nuclear Information System (INIS)

    Barboza, M.F. de; Pereira, N.S. de; Colturato, M.T.; Silva, C.P.G. da.

    1989-12-01

    Different solvents were used in paper chromatographic methods to obtain the best system in routine radiochemical control for 131 I-MIBG produced at IPEN-CNEN/SP. The dates were compared with those obtained with eletrophoresis method in buffer acetate, pH=4.5, 350V, during 40 minutes. The stability of the labeled compound store under 4 0 C was studied during 15 days. Miniaturized chromatographic procedures were established using Whatman 3MM (8x1cm) and n-butanol-:acetic acid: water (S:2:1) as a solvent. the Rf values were: 0.3 (I - ) and 1.0 (MIBG). The radiochemical purity was 99.3 and 99.2% (first day) obtained with eletrophoresis and miniaturized chromatographic procedures, respectively and, 84.7% after 15 days of its preparation. It is a rapid, practical and reproductive method. (author) [pt

  7. Advanced hyphenated chromatographic-mass spectrometry in mycotoxin determination: current status and prospects.

    Science.gov (United States)

    Li, Peiwu; Zhang, Zhaowei; Hu, Xiaofeng; Zhang, Qi

    2013-01-01

    Mass spectrometric techniques are essential for advanced research in food safety and environmental monitoring. These fields are important for securing the health of humans and animals, and for ensuring environmental security. Mycotoxins, toxic secondary metabolites of filamentous fungi, are major contaminants of agricultural products, food and feed, biological samples, and the environment as a whole. Mycotoxins can cause cancers, nephritic and hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders. Mycotoxin-contaminated food and feed can provoke trade conflicts, resulting in massive economic losses. Risk assessment of mycotoxin contamination for humans and animals generally depends on clear identification and reliable quantitation in diversified matrices. Pioneering work on mycotoxin quantitation using mass spectrometry (MS) was performed in the early 1970s. Now, unambiguous confirmation and quantitation of mycotoxins can be readily achieved with a variety hyphenated techniques that combine chromatographic separation with MS, including liquid chromatography (LC) or gas chromatography (GC). With the advent of atmospheric pressure ionization, LC-MS has become a routine technique. Recently, the co-occurrence of multiple mycotoxins in the same sample has drawn an increasing amount of attention. Thus, modern analyses must be able to detect and quantitate multiple mycotoxins in a single run. Improvements in tandem MS techniques have been made to achieve this purpose. This review describes the advanced research that has been done regarding mycotoxin determination using hyphenated chromatographic-MS techniques, but is not a full-circle survey of all the literature published on this topic. The present work provides an overview of the various hyphenated chromatographic-MS-based strategies that have been applied to mycotoxin analysis, with a focus on recent developments. The use of chromatographic-MS to measure levels of mycotoxins, including

  8. Chromatographic study of nucleosides and nucleotides of central nervous system. Identification and first results on changes after total gamma irradiation of brain

    International Nuclear Information System (INIS)

    Valle, C.; Marquer, C.; Pasquier, C.

    Changes of brain energetic state and of different levels after irradiation are studied. The results will be compared with the variations of brain electric activity due to irradiation. Using an ion exchange chromatographic method for separation and quantitative analysis of nucleotides, evaluation of adenylic nucleotides in brain rat have been chosen [fr

  9. Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS).

    Science.gov (United States)

    Boczkaj, Grzegorz; Kamiński, Marian

    2013-10-01

    Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantageous when gas chromatography is used for simulated distillation. This paper presents results from further research on the separation properties of empty fused silica tubing. The efficiency of this chromatographic system has been examined. The usefulness of such conditions has been studied for simulated distillation, i.e. to determine the boiling-point distribution of complex mixtures, mainly petroleum fractions and products, on the basis of their retention relative to reference substances. The results obtained by use of empty-column gas chromatography (EC-GC) and by use of classical simulated distillation columns have been compared for solutes of different polarity. Studies revealed boiling points determined by EC-GC were more accurate than those obtained by the standard method of simulated distillation.

  10. Separation of atropisomers by chiral liquid chromatography and thermodynamic analysis of separation mechanism

    Directory of Open Access Journals (Sweden)

    Ling Zhang

    2017-06-01

    Full Text Available In the pharmaceutical industry, the analysis of atropisomers is of considerable interest from a scientific and regulatory perspective. The compound of interest contains two stereogenic axes due to the hindered rotation around the single bonds connecting the aryl groups, which results in four potential configurational isomers (atropisomers. The separation of the four atropisomers is achieved on a derivatized β-cyclodextrin bonded stationary phase. Further investigation shows that low temperature conditions, including sample preparation (−70 °C, sample storage (−70 °C, and chromatographic separation (6 °C, were critical to preventing interconversion. LC-UV-Laser Polarimetric analysis identified peak 1/2 as a pair of enantiomers and peak 3/4 as another. Thermodynamic analysis of the retention data indicated that the separation of the pairs of enantiomers is primarily enthalpy controlled as indicated by the positive slope of the van’t Huff plot. The difference in absolute Δ (Δ H, ranged from 2.20 kJ/mol to 2.42 kJ/mol.

  11. Separation of Transfer Ribonucleic Acids by Reverse Phase Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kelmers, A. D.; Novelli, G. David; Stulberg, M. P.

    1965-10-01

    Numerous experimental techniques for the separation of transfer ribonucleic acids have been successful in preparing partially purified fractions of several specific t-RNAs. Many of the existing methods have depended upon the differential solubility of specific t-RNAs in complex two-phase systems (1-6) and the separation was achieved by means of counter-current extraction techniques. Column chromatography experiments using cellulose exchangers, (7,8) methylated albumin (9,10) or with solvent phases supported on inert material (11-13) have also shown partial separation of specific t-RNAs. Paper chromatographic procedures have produced partial resolutions of t-RNA.14 Methods involving chemical treatment of specific t-RNAs have been reported (15-19).

  12. Using High Performance Computing to Examine the Processes of Neurogenesis Underlying Pattern Separation/Completion of Episodic Information.

    Energy Technology Data Exchange (ETDEWEB)

    Aimone, James Bradley [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Betty, Rita [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    Using High Performance Computing to Examine the Processes of Neurogenesis Underlying Pattern Separation/Completion of Episodic Information - Sandia researchers developed novel methods and metrics for studying the computational function of neurogenesis, thus generating substantial impact to the neuroscience and neural computing communities. This work could benefit applications in machine learning and other analysis activities.

  13. Estimations of temperature deviations in chromatographic columns using isenthalpic plots. I. Theory for isocratic systems.

    Science.gov (United States)

    Tarafder, Abhijit; Iraneta, Pamela; Guiochon, Georges; Kaczmarski, Krzysztof; Poe, Donald P

    2014-10-31

    We propose to use constant enthalpy or isenthalpic diagrams as a tool to estimate the extent of the temperature variations caused by the mobile phase pressure drop along a chromatographic column, e.g. of its cooling in supercritical fluid and its heating in ultra-performance liquid chromatography. Temperature strongly affects chromatographic phenomena. Any of its variations inside the column, whether intended or not, can lead to significant changes in separation performance. Although instruments use column ovens in order to keep constant the column temperature, operating conditions leading to a high pressure drop may cause significant variations of the column temperature, both in the axial and the radial directions, from the set value. Different ways of measuring these temperature variations are available but they are too inconvenient to be employed in many practical situations. In contrast, the thermodynamic plot-based method that we describe here can easily be used with only a ruler and a pencil. They should be helpful in developing methods or in analyzing results in analytical laboratories. Although the most effective application area for this approach should be SFC (supercritical fluid chromatography), it can be applied to any chromatographic conditions in which temperature variations take place along the column due to the pressure drop, e.g. in ultra-high pressure liquid chromatography (UHPLC). The method proposed here is applicable to isocractic conditions only. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    International Nuclear Information System (INIS)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H.

    2005-12-01

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here

  15. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  16. Chromatographic studies of the lanthanide element separation for the americium/curium large scale separation using ion exchange resins

    International Nuclear Information System (INIS)

    Ginisty, Claude.

    1981-06-01

    The Am/Cm large scale separations, operated by chromatography with the use of ion exchange resins, are described by numerous publications. The bibliographic studies allow to retain the followed points: use of sulfonate cationic resins, development by elution with the α-hydroxyisobutyric acid, column loadings between 1 and 30% of the capacity, possibility to use no radioactive lanthanides prior to actinides for trial purposes. The optimisation of such a process is the major part of this thesis. This point is realised by introducing a new definition for the resolution, for non symmetrical elution peaks, and a measure of this dissymmetry by introducing a shape factor F. For the separation itself and for the pressure drop in the column, the influence of the following parameters are studied: composition of the elution solution (concentration and pH), column temperature (20 to 90 0 C), resin size (9 to 27 μm), rate flow of mobile phase (70 ml.cm -2 .mn -1 ), column length and diameter. Symmetrical elution peaks may be obtained, even with a 27% loading. Elution conditions may be modified during the separation process in order to have the best recovery for the two components (1,3 [fr

  17. Liquid chromatographic and ultraviolet spectrophotometric determination of bevantolol and hydrochlorothiazide in feeds.

    Science.gov (United States)

    Spurlock, C H; Schneider, H G

    1984-01-01

    Separate assay methods have been developed for the 2 components of an 80 + 20 drug blend of bevantolol and hydrochlorothiazide (HCT) in admixtures with animal feed. Drug/diet admixtures are extracted with methanol for reverse phase ion-pair liquid chromatographic (LC) assay of bevantolol, and with acetonitrile for ultraviolet spectrophotometric assay of HCT. Bevantolol, a cardioselective beta blocker, is separated from soluble feed components with an RP-18 column, using methanol-water-acetic acid (60 + 40 + 1) containing 0. 005M octane-sulfonic acid, sodium salt, as ion-pairing reagent. HCT is determined spectrophotometrically in acetonitrile extracts, using a suitable blank extract as reference. Average recovery of HCT from an admixture of 0.5 mg blend/g diet is 94.5% +/- 4.3 RSD and at 2.0 mg/g, 101.5% +/- 3.5 RSD. Bevantolol recovery from the same admixtures is 101.8% +/- 2.7 RSD and 99.0% +/- 3.5 RSD, respectively, using the method as described.

  18. Probabilistic classification method on multi wavelength chromatographic data for photosynthetic pigments identification

    Science.gov (United States)

    Prilianti, K. R.; Setiawan, Y.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2014-02-01

    Environmental and health problem caused by artificial colorant encourages the increasing usage of natural colorant nowadays. Natural colorant refers to the colorant that is derivate from living organism or minerals. Extensive research topic has been done to exploit these colorant, but recent data shows that only 0.5% of the wide range of plant pigments in the earth has been exhaustively used. Hence development of the pigment characterization technique is an important consideration. High-performance liquid chromatography (HPLC) is a widely used technique to separate pigments in a mixture and identify it. In former HPLC fingerprinting, pigment characterization was based on a single chromatogram from a fixed wavelength (one dimensional) and discard the information contained at other wavelength. Therefore, two dimensional fingerprints have been proposed to use more chromatographic information. Unfortunately this method leads to the data processing problem due to the size of its data matrix. The other common problem in the chromatogram analysis is the subjectivity of the researcher in recognizing the chromatogram pattern. In this research an automated analysis method of the multi wavelength chromatographic data was proposed. Principal component analysis (PCA) was used to compress the data matrix and Maximum Likelihood (ML) classification was applied to identify the chromatogram pattern of the existing pigments in a mixture. Three photosynthetic pigments were selected to show the proposed method. Those pigments are β-carotene, fucoxanthin and zeaxanthin. The result suggests that the method could well inform the existence of the pigments in a particular mixture. A simple computer application was also developed to facilitate real time analysis. Input of the application is multi wavelength chromatographic data matrix and the output is information about the existence of the three pigments.

  19. A simple subcritical chromatographic test for an extended ODS high performance liquid chromatography column classification.

    Science.gov (United States)

    Lesellier, Eric; Tchapla, Alain

    2005-12-23

    This paper describes a new test designed in subcritical fluid chromatography (SFC) to compare the commercial C18 stationary phase properties. This test provides, from a single analysis of carotenoid pigments, the absolute hydrophobicity, the silanol activity and the steric separation factor of the ODS stationary phases. Both the choice of the analytical conditions and the validation of the information obtained from the chromatographic measurements are detailed. Correlations of the carotenoid test results with results obtained from other tests (Tanaka, Engelhard, Sander and Wise) performed both in SFC and HPLC are discussed. Two separation factors, calculated from the retention of carotenoid pigments used as probe, allowed to draw a first classification diagram. Columns, which present identical chromatographic behaviors are located in the same area on this diagram. This location can be related to the stationary phase properties: endcapping treatments, bonding density, linkage functionality, specific area or silica pore diameter. From the first classification, eight groups of columns are distinguished. One group of polymer coated silica, three groups of polymeric octadecyl phases, depending on the pore size and the endcapping treatment, and four groups of monomeric stationary phases. An additional classification of the four monomeric groups allows the comparison of these stationary phases inside each group by using the total hydrophobicity. One hundred and twenty-nine columns were analysed by this simple and rapid test, which allows a comparison of columns with the aim of helping along their choice in HPLC.

  20. Rapid anion exchange separation of fermium with mineral acid-methyl alcohol mixed media

    International Nuclear Information System (INIS)

    Usuda, S.; Shinohara, N.; Ichikawa, S.; Suzuki, T.

    1987-01-01

    Anion exchange separation of 250 Fm (30 m) synthesized by the 12 C+ 242 Pu and 16 O+ 238 U reactions was investigated with mineral acid-methyl alcohol mixed media at elevated temperature. Fermium was chromatographically separated from the other transplutonium elements, the target materials and an Al catcher foil by anion exchange with mixtures of nitric acid and methyl alcohol. By use of the mixed media of hydrochloric acid and methyl alcohol, Fm together with Cf was separated from Al, Am, Cm, Pu, U and from major fission products. The separation systems are suitable for rapid separation and immediate alpha-counting source preparation of Fm. (author) 22 refs.; 4 figs

  1. Multiple chromatographic fingerprinting and its application to the quality control of herbal medicines

    Energy Technology Data Exchange (ETDEWEB)

    Fan Xiaohui [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China); Cheng Yiyu [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China)]. E-mail: chengyy@zju.edu.cn; Ye Zhengliang [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China); Lin Ruichao [National Institute for the Control of Pharmaceutical and Biological Products, Beijing 100050 (China); Qian Zhongzhi [Committee of Chinese Pharmacopoeia, Beijing 100061 (China)

    2006-01-12

    Recently, chromatographic fingerprinting has become one of the most powerful approaches to quality control of herbal medicines. However, the performance of reported chromatographic fingerprinting constructed by single chromatogram sometimes turns out to be inadequate for complex herbal medicines, such as multi-herb botanical drug products. In this study, multiple chromatographic fingerprinting, which consists of more than one chromatographic fingerprint and represents the whole characteristics of chemical constitutions of the complex medicine, is proposed as a potential strategy in this complicated case. As a typical example, a binary chromatographic fingerprinting of 'Danshen Dropping Pill' (DSDP), the best-sold traditional Chinese medicine in China, was developed. First, two HPLC fingerprints that, respectively, represent chemical characteristics of depsides and saponins of DSDP were developed, which were used to construct binary chromatographic fingerprints of DSDP. Moreover, the authentication and validation of the binary fingerprints were performed. Then, a data-level information fusion method was employed to capture the chemical information encoded in two chromatographic fingerprints. Based on the fusion results, the lot-to-lot consistency and frauds can be determined either using similarity measure or by chemometrics approach. The application of binary chromatographic fingerprinting to consistency assessment and frauds detection of DSDP clearly demonstrated that the proposed method was a powerful approach to quality control of complex herbal medicines.

  2. Theory and applications of a novel ion exchange chromatographic technology using controlled pH gradients for separating proteins on anionic and cationic stationary phases.

    Science.gov (United States)

    Tsonev, Latchezar I; Hirsh, Allen G

    2008-07-25

    pISep is a major new advance in low ionic strength ion exchange chromatography. It enables the formation of externally controlled pH gradients over the very broad pH range from 2 to 12. The gradients can be generated on either cationic or anionic exchangers over arbitrary pH ranges wherein the stationary phases remain totally charged. Associated pISep software makes possible the calculation of either linear, nonlinear or combined, multi-step, multi-slope pH gradients. These highly reproducible pH gradients, while separating proteins and glycoproteins in the order of their electrophoretic pIs, provide superior chromatographic resolution compared to salt. This paper also presents a statistical mechanical model for protein binding to ion exchange stationary phases enhancing the electrostatic interaction theory for the general dependence of retention factor k, on both salt and pH simultaneously. It is shown that the retention factors computed from short time isocratic salt elution data of a model protein can be used to accurately predict its salt elution concentration in varying slope salt elution gradients formed at varying isocratic pH as well as the pH at which it will be eluted from an anionic exchange column by a pISep pH gradient in the absence of salt.

  3. A Selective High Performance Liquid Chromatographic Method to Follow the Hydrolytic Degradation of Nicardipine Hydrochloride

    Directory of Open Access Journals (Sweden)

    K. E. Ibrahim

    2010-01-01

    Full Text Available A simple, stability indicating, reverse phase high performance liquid chromatographic method was developed and validated for determination of nicardipine hydrochloride (NC in the presence of its degradation products. The chromatographic separation was performed on Hypersil, BDS-C18, 30 cm × 3.9 mm id, at ambient temperature with UV-detection at 254 nm. A mixture of 20% (v/v aqueous 0.01 M sodium acetate∕acetic acid buffer (pH 4.5 and 80% acetonitrile was used as the mobile phase at a flow rate of 1.5 mL min-1, losartan was used as internal standard. The calibration curve is linear over the concentration range 5-40 μg mL-1, with a regression coefficient of 0.9984 and the % recovery was 99.78±0.17. The method was used to investigate the kinetics of alkaline, acids induced degradation, effect of buffer concentration and temperature. The degradation followed first-order kinetics. The rate constant, half-life time, and activation energy were calculated

  4. Column liquid chromatography applied to concentrating, separating, and determining platinum metals

    International Nuclear Information System (INIS)

    Alimarin, I.P.; Basova, E.M.; Bol'shova, T.A.; Ivanov, V.M.

    1986-01-01

    The present survey deals with high-performance liquid chromatography (HPLC) in relation to the chromatographic behavior of the platinum metals, including separation and determination. The data shows that HPLC is the most promising and effective method of separating metals, including platinum ones. The method provides efficient separation of microgram amoounts of mixtures with a resolving power 3-20 times that of thin-layer chromatography. It is shown that the most promising line of advance in HPLC for inorganic systems lies in the separation and determination of metals as chelates by absorption or ion-pair chromatography. Examples of using HPLC for determining noble metals in particular cases indicate that the metrological characteristics are favorable

  5. Temperature Control of Gas Chromatograph Based on Switched Delayed System Techniques

    Directory of Open Access Journals (Sweden)

    Xiao-Liang Wang

    2014-01-01

    Full Text Available We address the temperature control problem of the gas chromatograph. We model the temperature control system of the gas chromatograph into a switched delayed system and analyze the stability by common Lyapunov functional technique. The PI controller parameters can be given based on the proposed linear matrix inequalities (LMIs condition and the designed controller can make the temperature of gas chromatograph track the reference signal asymptotically. An experiment is given to illustrate the effectiveness of the stability criterion.

  6. High performance liquid chromatographic determination of vanadium in crude oils and cobalt and iron in pharmaceutical preparations

    International Nuclear Information System (INIS)

    Khuhawar, M.Y.; Lanjwani, S.N.; Khaskhely, G.Q.

    1993-01-01

    High performance liquid Chromatographic (HPLC) method has ben developed for the determination of vanadium in crude oils, based on acid decomposition of oils, followed by complexation with bis (salicylaldehyde) tetramethyl ethylenediamine (H2SA2Ten). The complex is extracted in organic phase and is separated from copper and nickel using normal phase HPLC column. Detection is achieved using spectrophtmetric detector. The vanadium in oil is obtained at sub microgram/g level. Similarly cobalt(II), cobalt(III) and iron(II) are separated on reversed phase HPLC column. Pre column derivatization is used to develop HPLC method for the determination of cobalt and iron in pharmaceutical preparations. Finally results are compared using atomic absorption spectrometer. (author)

  7. Headspace solid-phase microextraction procedures for gas chromatographic analysis of biological fluids and materials.

    Science.gov (United States)

    Mills, G A; Walker, V

    2000-12-01

    Solid-phase microextraction (SPME) is a new solventless sample preparation technique that is finding wide usage. This review provides updated information on headspace SPME with gas chromatographic separation for the extraction and measurement of volatile and semivolatile analytes in biological fluids and materials. Firstly the background to the technique is given in terms of apparatus, fibres used, extraction conditions and derivatisation procedures. Then the different matrices, urine, blood, faeces, breast milk, hair, breath and saliva are considered separately. For each, methods appropriate for the analysis of drugs and metabolites, solvents and chemicals, anaesthetics, pesticides, organometallics and endogenous compounds are reviewed and the main experimental conditions outlined with specific examples. Then finally, the future potential of SPME for the analysis of biological samples in terms of the development of new devices and fibre chemistries and its coupling with high-performance liquid chromatography is discussed.

  8. Liquid Chromatographic-Chemometric Techniques for the Simultaneous HPLC Determination of Lansoprazole, Amoxicillin and Clarithromycin in Commercial Preparation.

    Science.gov (United States)

    Aktas, A Hakan; Saridag, Ayse Mine

    2017-09-01

    Two multivariate calibration-prediction techniques, principal component regression (PCR) and partial least-squares regression (PLSR) were applied to the chromatographic multicomponent analysis of the drug containing lansoprazole (LAN), clarithromycin (CLA) and amoxicillin (AMO). Optimum chromatographic separation of LAN, CLA and AMO with atorvastatin as the internal standard (IS) was obtained by using Xterra® RP18 column 5 μm 4.6 × 250 mm2, and 25 mM ammonium chloride buffer prepared ammonium chloride, acetonitrile and bidistilled water (45:45:10 v/v) as the mobile phase at flow rate 1.0 mL/min. The high pressure liquid chromatography data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using diode array detector detection at five wavelengths (205, 210, 215, 220 and 225 nm). LC-chemometric calibration for LAN, CLA and AMO were separately constructed by using the relationship between the peak-area ratio and training sets for each analyte. A series of synthetic solutions containing different concentrations of LAN, CLA and AMO were used to check the prediction ability of the PCR and PLS. Both of the two-chemometric methods in this study can be satisfactorily used for the quantitative analysis and for dissolutions tests of multicomponent commercial drug. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. The development of 126Sn separation procedure by means of TBP resin

    International Nuclear Information System (INIS)

    Andris, Boris; Bena, Jozef

    2016-01-01

    Separation possibilities of 126 Sn with a new extraction-chromatographic material TBP Resin were studied. Suitable conditions for tin separation were determined in hydrochloric acid medium. 126 Sn was concentrated on TBP resin from 6 mol L -1 HCl and was eluted with 0.1 mol L -1 HCl. A purification step to remove 137 Cs with AMP-PAN column was necessary to obtain sufficiently purified samples which were directly measured with gamma spectrometry for 126 Sn activity. Separation of 126 Sn from a raw sludge sample was done according to proposed procedure, 126 Sn was detected and its activity was determined. (author)

  10. Study PWA8 resin for chromatographic uranium concentration

    International Nuclear Information System (INIS)

    Coceancigh, Herman; Ramella, J. L.; Marrero, Julieta; Jiménez Rebagliati, Raúl

    2013-01-01

    For many years nuclear industry have been using resins as filler of chromatographic columns. These methods are specific and give reliable results in different applications, for those reasons are extremely useful as separation process. Currently the nuclear industry is growing and this brings new issues such as the need of reduction of the amount of waste, the optimization of the production process and others that the chromatography could solve with great results. AMBERLITETM PWA8 resin is an anion exchange resin which can be used for the removal of uranium from drinking water. In addition to high exchange capacity, this resin has excellent physical stability and a wide range of pH in which is operational. With the idea of concentrating uranium from wastes solution as main goal we made different experiments to understand the AMBERLITETM PWA8 and obtain the most important characteristics like; pH working range; capacity; activation and elution procedures. These procedures were developed and optimized the capacity was determined using a batch experiment and we obtain that the maximum capacity is 882,5 U ug /resin gr at a pH of 4,2. Following on from these results chromatographic experiments were performed in which both were obtained the percentage of recovery and the concentration factor. The percent recovery (% R) calculated as the percentage ratio between the total mass and the load mass eluted (% R = eluted mass / total mass * 100) was 94% with a concentration factor of 5 times From these results it is intended to concentrate wastes solutions from the fuel cycle processes with two main goals: decreasing volume for storage and for future reusing of the uranium coming from production. (author)

  11. Analyzing chromatographic data using multilevel modeling.

    Science.gov (United States)

    Wiczling, Paweł

    2018-06-01

    It is relatively easy to collect chromatographic measurements for a large number of analytes, especially with gradient chromatographic methods coupled with mass spectrometry detection. Such data often have a hierarchical or clustered structure. For example, analytes with similar hydrophobicity and dissociation constant tend to be more alike in their retention than a randomly chosen set of analytes. Multilevel models recognize the existence of such data structures by assigning a model for each parameter, with its parameters also estimated from data. In this work, a multilevel model is proposed to describe retention time data obtained from a series of wide linear organic modifier gradients of different gradient duration and different mobile phase pH for a large set of acids and bases. The multilevel model consists of (1) the same deterministic equation describing the relationship between retention time and analyte-specific and instrument-specific parameters, (2) covariance relationships relating various physicochemical properties of the analyte to chromatographically specific parameters through quantitative structure-retention relationship based equations, and (3) stochastic components of intra-analyte and interanalyte variability. The model was implemented in Stan, which provides full Bayesian inference for continuous-variable models through Markov chain Monte Carlo methods. Graphical abstract Relationships between log k and MeOH content for acidic, basic, and neutral compounds with different log P. CI credible interval, PSA polar surface area.

  12. High performance separation of lanthanides and actinides

    International Nuclear Information System (INIS)

    Sivaraman, N.; Vasudeva Rao, P.R.

    2011-01-01

    The major advantage of High Performance Liquid Chromatography (HPLC) is its ability to provide rapid and high performance separations. It is evident from Van Deemter curve for particle size versus resolution that packing materials with particle sizes less than 2 μm provide better resolution for high speed separations and resolving complex mixtures compared to 5 μm based supports. In the recent past, chromatographic support material using monolith has been studied extensively at our laboratory. Monolith column consists of single piece of porous, rigid material containing mesopores and micropores, which provide fast analyte mass transfer. Monolith support provides significantly higher separation efficiency than particle-packed columns. A clear advantage of monolith is that it could be operated at higher flow rates but with lower back pressure. Higher operating flow rate results in higher column permeability, which drastically reduces analysis time and provides high separation efficiency. The above developed fast separation methods were applied to assay the lanthanides and actinides from the dissolver solutions of nuclear reactor fuels

  13. Extraction Separation of Am(III) and Eu(III) with Thermo-sensitive Gel introducing TPEN Derivatives

    International Nuclear Information System (INIS)

    Kenji Takeshita; Yoshio Nakano; Tatsuro Matsumura; Atsunori Mori

    2008-01-01

    A thermal-swing chromatographic process using a thermo-sensitive gel co-polymerized with NIPA (N-isopropyl-acrylamide) and TPPEN (N,N,N',N'-tetrakis(4-propenyl-oxy-2-pyridyl-methyl)ethylenediamine) was studied for the separation of Am(III) from Eu(III). First, the radiolysis of the TPPEN-NIPA gel was tested by the γ-ray irradiation and the α nuclide adsorption. The extraction separation of Am(III) was not influenced in the radioactive environment of the proposed process. Next, the TPPEN-NIPA gel was immobilized in porous silica particles and the applicability of the gel-immobilized silica to the proposed process was tested. Am(III) was extracted selectively in the gel-immobilized silica at 5 deg. C and the separation factor of Am(III) over Eu(III) was evaluated to be 3.7. The distribution ratio of Am(III) was reduced to less than 1/20 by increasing temperature from 5 deg. C to 40 deg. C. These results indicate that the TPPEN-NIPA gel is applicable to the thermal-swing chromatographic process for the minor actinide recovery. (authors)

  14. [Separation and determination of eight plant hormones by reversed-phase high performance liquid chromatography].

    Science.gov (United States)

    Fang, N; Hou, S; Shao, X; He, Y; Zhao, G

    1998-09-01

    In this paper, reversed-phase high performance liquid chromatographic technique was used for the separation and determination of eight plant hormones. Methanol-water-acetic acid system was chosen as the mobile phase. The effects of different separation conditions, such as the methanol and acetic acid concentrations in mobile phase, on the retention behaviours of eight plant hormones in this system were studied. The general trends in retention behaviours could be correlated to the methanol concentration in mobile phase. The experimental results showed that the optimum separation was achieved with following gradient elution condition: 0-3 minutes, 70% (water percentage in mobile phase), 3-13 minutes, 70%-20%, 13-48 minutes, 20%. Benzene was added to be as the internal standard. Under this experimental condition, the eight plant hormones could be separated completely and detected quantitatively at 260 nm within 16 minutes. The calibration curves for the eight compounds gave linearity over a wide range. The correlation coefficients of each components were r(ZT) = 0.9971, r(GAs) = 0.9999, r(K) = 0.9997, r(BA) = 0.9995, r(IAA) = 0.9998, r(IPA) = 0.9982, r(IBA) = 0.9995 and r(NAA) = 0.9995. The method is rapid, simple and efficient. It is a suitable method for the accurate determination of gibberellic acid (GA) and alpha-naphthaleneacetic acid (alpha-NAA) in products for agricultural use.

  15. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    Science.gov (United States)

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  16. Chromatographic purification of neutron capture molybdenum-99 from cross-contaminant radionuclides

    International Nuclear Information System (INIS)

    Mostafa, M.A.M.

    2011-01-01

    Technetium-99m is called the work horse, for many reasons, in nuclear medicine diagnostic purposes. It is produced as the β - decay of 99 Mo radionuclide. Molybdenum-99 gel type generators are considered as a suitable alternative of the conventional chromatographic alumina columns loaded with fission molybdenum-99. 99 Mo neutron-capture is cross-contaminated with radionuclides originated from activation of chemical impurities in the Mo target such 60 C0, 65 Zn, 95 Zr, 175 Hf, 181 Hf, 86 Rb, 134 Cs, 141 Ce, 152 Eu, 140 La, 51 Cr, 124 Sb, 46 Sc, 54 Mn, 59 Fe and / or fast neutrons interactions with the stable isotopes of molybdenum such as 92m Nb, 95 Nb and 95 Zr. To prevent contamination of the eluted 99m Tc, successive purification methods were made. After complete dissolution of the irradiated target wrapped with thin Al foil in 5 M NaOH solution, hydrogen peroxide was added to start precipitation of Fe(OH) 3 . The formed Fe (III) minerals allow complete elimination of some radio contaminants from the molybdate solute such as 152 Eu, 140 La, 141 Ce, 45 Mn and 92m Nb in addition to partial elimination of 46 Sc, 60 Co and 59 Fe radionuclides. The remaining supernatant was acidified by concentrated nitric acid to ph 9.5 for precipitation of Al(OH) 3 with complete elimination of radio contaminants such as 95 Zr 175 Hf, 181 Hf, 65 Zn, 124 Sb, 51 Cr, 46 Sc, 60 Co and 59 Fe. 134 Cs and 86 Rb radionuclides were not affected by precipitation of Fe(OH) 3 or Al(OH) 3 . Chromatographic column of potassium nickel hexacyanoferrate (II) (KNHCF) has high affinity towards elimination of 134 Cs and 86 Rb radionuclides. Highly pure molybdate- 99 Mo solution was processed for preparation of zirconium molybdate gel generator with 99m Tc eluate of high radionuclidic, radiochemical and chemical purity suitable for use in medical purposes.

  17. Mixed-mode chromatographic matrices for the resolution of transfer ribonucleic acids

    NARCIS (Netherlands)

    Bischoff, Rainer; Mclaughlin, L.W.

    1984-01-01

    Modification of approximately 65% of the amine groups of an aminopropylsilyl bonded-phase silica high-performance liquid chromatographic anion exchanger (APS-Hypersil) with organic acids containing n-alkyl moieties of different chain lengths, results in mixed mode chromatographic matrices of varying

  18. Selective micellar electrokinetic chromatographic method for simultaneous determination of some pharmaceutical binary mixtures containing non-steroidal anti-inflammatory drugs

    Directory of Open Access Journals (Sweden)

    Michael E. El-Kommos

    2013-02-01

    Full Text Available A simple and selective micellar electrokinetic chromatographic (MEKC method has been developed for the analysis of five pharmaceutical binary mixtures containing three non-steroidal anti-inflammatory drugs (NSAIDs. The investigated mixtures were Ibuprofen (IP–Paracetamol (PC, Ibuprofen (IP–Chlorzoxazone (CZ, Ibuprofen (IP–Methocarbamol (MC, Ketoprofen (KP–Chlorzoxazone (CZ and Diclofenac sodium (DS–Lidocaine hydrochloride (LC. The separation was run for all mixtures using borate buffer (20 mM, pH 9 containing 15% (v/v methanol and 100 mM sodium dodecyl sulphate (SDS at 15 kV and the components were detected at 214 nm. Different factors affecting the electrophoretic mobility of the seven investigated drugs were studied and optimized. The method was validated according to international conference of harmonization (ICH guidelines and United States pharmacopoeia (USP. The method was applied to the analysis of five pharmaceutical binary mixtures in their dosage forms. The results were compared with other reported high performance liquid chromatographic methods and no significant differences were observed. Keywords: Capillary electrophoresis, Micellar electrokinetic chromatographic method, Non-steroidal anti-inflammatory drugs, Pharmaceutical binary mixtures, Pharmaceutical analysis

  19. Recent Progress in Asymmetric Catalysis and Chromatographic Separation by Chiral Metal–Organic Frameworks

    Directory of Open Access Journals (Sweden)

    Suchandra Bhattacharjee

    2018-03-01

    Full Text Available Metal–organic frameworks (MOFs, as a new class of porous solid materials, have emerged and their study has established itself very quickly into a productive research field. This short review recaps the recent advancement of chiral MOFs. Here, we present simple, well-ordered instances to classify the mode of synthesis of chiral MOFs, and later demonstrate the potential applications of chiral MOFs in heterogeneous asymmetric catalysis and enantioselective separation. The asymmetric catalysis sections are subdivided based on the types of reactions that have been successfully carried out recently by chiral MOFs. In the part on enantioselective separation, we present the potentiality of chiral MOFs as a stationary phase for high-performance liquid chromatography (HPLC and high-resolution gas chromatography (GC by considering fruitful examples from current research work. We anticipate that this review will provide interest to researchers to design new homochiral MOFs with even greater complexity and effort to execute their potential functions in several fields, such as asymmetric catalysis, enantiomer separation, and chiral recognition.

  20. Performance of chromatographic systems to model soil-water sorption.

    Science.gov (United States)

    Hidalgo-Rodríguez, Marta; Fuguet, Elisabet; Ràfols, Clara; Rosés, Martí

    2012-08-24

    A systematic approach for evaluating the goodness of chromatographic systems to model the sorption of neutral organic compounds by soil from water is presented in this work. It is based on the examination of the three sources of error that determine the overall variance obtained when soil-water partition coefficients are correlated against chromatographic retention factors: the variance of the soil-water sorption data, the variance of the chromatographic data, and the variance attributed to the dissimilarity between the two systems. These contributions of variance are easily predicted through the characterization of the systems by the solvation parameter model. According to this method, several chromatographic systems besides the reference octanol-water partition system have been selected to test their performance in the emulation of soil-water sorption. The results from the experimental correlations agree with the predicted variances. The high-performance liquid chromatography system based on an immobilized artificial membrane and the micellar electrokinetic chromatography systems of sodium dodecylsulfate and sodium taurocholate provide the most precise correlation models. They have shown to predict well soil-water sorption coefficients of several tested herbicides. Octanol-water partitions and high-performance liquid chromatography measurements using C18 columns are less suited for the estimation of soil-water partition coefficients. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A simple method for the measurement of radioactivity of samples separated by gas chromatography

    International Nuclear Information System (INIS)

    Farkas, T.

    1981-01-01

    Gas chromatographs with flame ionization detector can be used to determine the radioactivity ( 14 C) of separated peaks. After a suitable change in the detector output the combustion product 14 CO 2 can be trapped by hyamine hydroxyde and measured by liquid scintigraphy. 90% of peak activity can be collected and measured, thus the method can be applied to determine the distribution and specific radioactivity of the components separated by gas chromatography. (author)

  2. Integrating Carbon Nanotubes into Microfluidic Chip for Separating Biochemical Compounds

    DEFF Research Database (Denmark)

    Chen, Miaoxiang Max; Mogensen, Klaus Bo; Bøggild, Peter

    2012-01-01

    We present a new type of device to separate biochemical compounds wherein carbon nanotubes (CNTs) are integrated as chromatographic stationary phase. The CNTs were directly grown on the bottom of microfluidic channels on Si/SiO2 substrates by chemical vapor deposition (CVD). Acetylene was used...... as carbon source and Ni was employed as catalyst. For electrokinetic separations, higher electrical field strength is usually required; therefore, the CNTs were constructed in pillar-array-form by patterning the catalyst layer. Electrical field strength of 2.0 kV/cm has been realized, which is more than one...

  3. Chromatographic and biological aspects of organomercurials

    Energy Technology Data Exchange (ETDEWEB)

    Fishbein, L

    1970-01-01

    A thorough review on the biological and chromatographic aspects of methylmercury, phenylmercurials, and miscellaneous organomercurials is presented. Areas covered include ecology, epidemiology, paper chromatography, thin-layer chromatography, gas chromatography, metabolism and toxicity, and environmental degradation. 183 references.

  4. Extraction chromatographic separation of iron from complex liquid samples and the determination of 55Fe

    International Nuclear Information System (INIS)

    Grahek, Z.; Rozmaric Macefat, M.

    2006-01-01

    Iron separation is described from liquid samples with a high concentration of ions that enables simple determination of 55 Fe. One of the described methods consists of iron precipitation from a large volume seawater by sodium hydroxide and/or ammonium carbonate and separation from other elements (Ca, Sr, Cu, Mg, etc.) on a TRU column with 4M HCl or 8M HNO 3 . In the other procedure iron is separated directly from a mixture of seawater samples and HCl on a TRU column. In both methods, the iron recovery is almost 100%. After separation, 55 Fe is determined by counting with a liquid scintillation counter. The binding of Fe and Zn on TEVA, U/TEVA and TRU resins from seawater solutions of HCl and HNO 3 depends on the type of the resin, concentration of acid and other ions. Iron and zinc can be separated from seawater on a U/TEVA column with 2M HCl. (author)

  5. Development of immobilized ligands for actinide separations

    International Nuclear Information System (INIS)

    Paine, R.T.

    1994-01-01

    Primary goals during this grant period were to (1) synthesize new bifunctional chelating ligands, (2) characterize the structural features of the Ln and An coordination complexes formed by these ligands, (3) use structural data to iteratively design new classes of multifunctional ligands, and (4) explore additional routes for attachment of key ligands to solid supports that could be useful for chromatographic separations. Some highlights of recently published work as well as a summary of submitted, unpublished and/or still in progress research are outlined

  6. CHROMATOGRAPHIC SEPARATION AND SPECTRO ...

    African Journals Online (AJOL)

    Bulletin of the Chemical Society of Ethiopia ... Four different fractions having colours yellow, grey, orange and purple were obtained from ... The optical microscopic investigation gave indication that the dyes are likely to be of the marine origin.

  7. The role seemingly of amorphous silica gel layers in chiral separations by planar chromatography

    International Nuclear Information System (INIS)

    Sajewicz, M.; Kowalska, T.

    2007-01-01

    In planar chromatography, silica gel appears as the most frequently used adsorbent. Its preference as planar chromatographic stationary phase is due to its high specific surface area (ca. 700 m2 gl) and relatively simple active sites (silanol groups =Si-OH). The high specific surface area of silica gel and a high density of coverage of its surface with the silanol active sites contribute jointly to an excellent separation performance of this adsorbent. In our experiments on chiral separation of the enantiomer pairs by planar chromatography, contradictory behavior of the silica gel layers versus the chiral compounds was observed. The migration tracks of chiral compounds in the ascending planar chromatographic mode were not vertical but bent on either side being a function of analyte chirality. This deviation of the analytes migration track was noticed, when using the densitometric scanner to quantify the respective chromatograms. In order to confirm the hypothesis as to the microcrystalline nature of silica gel used in liquid chromatography, it was further investigated through circular dichroism (CD) and the data thereof confirmed that the chromatographic silica gels are not amorphous but microcrystalline, contributing to the (partial) horizontal enantioseparation of the antimer pairs. This paper summarizes the results of our investigation on the microcrystalline nature of silica gels used in planar chromatography and their impact on enantioseparation of the selected pairs of antimers. (author)

  8. [Reversed-phase high-performance liquid chromatograph--application to serum aluminium monitoring].

    Science.gov (United States)

    Hoshino, H; Kaneko, E

    1996-01-01

    High-Performance Liquid Chromatography (HPLC) with the reversed-phase partition mode separation (including ion-pair one) towards metal chelate compounds prepared in an off-line fashion (precolumn chelation) is most versatile in terms of high sensitivity with base-line flatness, unique selectivity and cost effectiveness. The extraordinary toughness to the complicated matrices encountered in clinical testing is exemplified by the successful application to the aluminium monitoring of human serum samples. The A1 chelate with 2,2'-dihydroxyazobenzene is efficiently chromatographed on a LiChroCART RP-18 column using an aqueous methanol eluent (63.6 wt%) containing tetrabutylammonium bromide as an ion-pair agent. The serum concentration level of A1 down to 6 micrograms dm-3 is readily monitored without influences from iron, chyle and haemolysis.

  9. Chromatographic studies of thorium(IV) and its extraction from monazite sand

    International Nuclear Information System (INIS)

    Bandyopadhyay, Arup; Roy, Uday Sankar

    1998-01-01

    A simple, rapid and selective method has been developed for reversed phase extraction chromatographic studies of Th IV with high molecular mass monocarboxylic acid (C 15 -C 16 ), SRS-100 as a stationary phase on a column of silica gel. Quantitative extraction of Th IV has been achieved in the pH range 4.8-5.5. The extracted Th IV has been stripped with 1:1 (v/v) mixture of 0.2 M HNO 3 and 0.2 M NaNO 3 and estimated spectrophotometrically. The effect of variables as pH, stripping agents, flow rate on extraction and elution have been studied. Th IV has been separated from various commonly associated elements in binary and synthetic multicomponent mixtures. The method has been applied successfully for the extraction of thorium from monazite sand. (author)

  10. Separation and determination of alditols and sugars by high-pH anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Andersen, Rikke; Sørensen, A.

    2000-01-01

    Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic-pulsed a......Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic......-pulsed amperometric detection (HPAEC-PAD) method that determines all the polyols used as food additives in food products and the most commonly found mono- and disaccharides on a routine basis. The linearity, repeatability, internal reproducibility and accuracy are described. The applicability of the method has been...

  11. A Quantitative Gas Chromatographic Ethanol Determination.

    Science.gov (United States)

    Leary, James J.

    1983-01-01

    Describes a gas chromatographic experiment for the quantitative determination of volume percent ethanol in water ethanol solutions. Background information, procedures, and typical results are included. Accuracy and precision of results are both on the order of two percent. (JN)

  12. Comparison of twin-cell centrifugal partition chromatographic columns with different cell volume.

    Science.gov (United States)

    Goll, Johannes; Audo, Gregoire; Minceva, Mirjana

    2015-08-07

    Two twin-cell centrifugal partition chromatographic columns (SCPC 250 and SCPE-250-BIO, Armen Instrument, France) with the same column volume but different cell size and number were compared in terms of stationary phase retention and column efficiency. The columns were tested with two types of solvent systems: a commonly used organic solvent based biphasic system from the ARIZONA solvent system family and a polymer/salt based aqueous two phase system (ATPS). The efficiency of the columns was evaluated by pulse injection experiments of two benzenediols (pyrocatechol and hydroquinone) in the case of the ARIZONA system and a protein mixture (myoglobin and lysozyme) in the case of the ATPS. As result of high stationary phase retention, the column with the lower number of larger twin-cells (SCPE-250-BIO) is suitable for protein separations using ATPS. On the other hand, due to higher column efficiency, the column with the greater number of smaller cells (SCPC 250) is superior for batch elution separations performed with standard liquid-liquid chromatography organic solvent based biphasic systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Optimization of startup and shutdown operation of simulated moving bed chromatographic processes.

    Science.gov (United States)

    Li, Suzhou; Kawajiri, Yoshiaki; Raisch, Jörg; Seidel-Morgenstern, Andreas

    2011-06-24

    This paper presents new multistage optimal startup and shutdown strategies for simulated moving bed (SMB) chromatographic processes. The proposed concept allows to adjust transient operating conditions stage-wise, and provides capability to improve transient performance and to fulfill product quality specifications simultaneously. A specially tailored decomposition algorithm is developed to ensure computational tractability of the resulting dynamic optimization problems. By examining the transient operation of a literature separation example characterized by nonlinear competitive isotherm, the feasibility of the solution approach is demonstrated, and the performance of the conventional and multistage optimal transient regimes is evaluated systematically. The quantitative results clearly show that the optimal operating policies not only allow to significantly reduce both duration of the transient phase and desorbent consumption, but also enable on-spec production even during startup and shutdown periods. With the aid of the developed transient procedures, short-term separation campaigns with small batch sizes can be performed more flexibly and efficiently by SMB chromatography. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Rapid separation of lanthanides and actinides on small particle based reverse phase supports

    Energy Technology Data Exchange (ETDEWEB)

    Datta, A.; Sivaraman, N.; Srinivasan, T.G.; Vasudeva Rao, P.R. [Chemistry Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    2010-07-01

    This paper presents the results on the use of short columns (3-5 cm long) with small particle size (1.8 {mu}m) for high performance liquid chromatographic separation of individual lanthanides and uranium from plutonium as well as uranium from thorium to achieve rapid separations i.e. separation time as short as 3.6 min for individual lanthanides, 1 min for thorium-uranium and 4.2 min for uranium from plutonium. These advantages can be exploited to significantly reduce analysis time, liquid waste generation as well as dose to operator when radioactive samples are analysed e.g. burn-up determination. In the present work, a dynamic ion-exchange chromatographic separation technique was employed using camphor-10-sulfonic acid (CSA) as the ion-pairing reagent and {alpha}-hydroxy isobutyric acid ({alpha}-HIBA) as the complexing reagent for the isolation of individual lanthanides as well as the separation of uranium from thorium. Uranium was separated from Pu(III) as well as Pu(IV) by reverse phase HPLC technique. The reverse phase HPLC was also investigated for the isolation and quantitative determination of uranium from thorium as well as lanthanide group from uranium. The dynamic ion-exchange technique using small particle support was demonstrated for measuring the concentrations of lanthanide fission products such as La, Ce, Pr, Nd and Sm in the dissolver solution of fast reactor fuel. Similarly, the assay of uranium in the dissolver solution of fast reactor was carried out using reverse phase HPLC technique. The rapid separation technique using reverse phase HPLC was also demonstrated for separation of lanthanides as a group from uranium matrix; samples of LiCl-KCl eutectic salt containing chlorides of lanthanides in uranium matrix (typically 1: 2000) were analysed. (orig.)

  15. Evaluation of the separation and purification of 227Th from its decay progeny by anion exchange and extraction chromatography

    International Nuclear Information System (INIS)

    Ivanov, P.I.; Collins, S.M.; Es, E.M. van; García-Miranda, M.; Jerome, S.M.; Russell, B.C.

    2017-01-01

    Thorium-227 is currently undergoing evaluation as a potential radionuclide for targeted cancer therapy, and as such a high chemical purity of the material is required. To establish a reliable procedure for radiochemical isolation of 227 Th from the parent 227 Ac and decay progeny, which includes the radiotherapeutic 223 Ra, the performance of three different separation schemes based on ion-exchange and extraction chromatography have been evaluated. The results suggest that both ion exchange and extraction chromatographic techniques can be successfully used for the separation of 227 Th from its decay progeny, however extraction chromatographic resins demonstrate favourable performance in terms of Th recovery and purification from radionuclide impurities. - Highlights: • Development of a radiochemical separation of 227 Th from residual 227Ac as well as from decay progeny. • Evaluation of ion-exchange and extraction chromatography techniques. • TEVA resin demonstrates favourable performance in terms of Th recovery and purification. • Developed method is applicable to both nuclear medicine and environmental analysis.

  16. Analytical method of Kr-85 determination, using cryogenic concentration and separation and liquid scintillation counting

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.; Grau Malonda, A.

    1983-01-01

    The method used in the Laboratory of the JEN for the determination of Kr-85 levels in gaseous effluents of nuclear power and in the atmosphere is described. Samples of air, collected in metallic cylinders, are introduced into a gas-solid chromatographic separation system which resolves Kr from the other air components. The separated Kr ia dissolved in a toluene based scintillation cocktail, and the Kr-85 content is determined by liquid scintillation counting. (Author)

  17. Liquid chromatographic analysis of phenobarbitone, ethosuximide ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous assay of four anticonvulsant drugs, phenobarbitone, ethosuximide, phenytoin and carbamazepine on a polystyrene-divinyl benzene column is described. The method was developed by the systematic study of different types of co-polymer materials, type and ...

  18. Chemical Separation of Fission Products in Uranium Metal Ingots from Electrolytic Reduction Process

    International Nuclear Information System (INIS)

    Lee, Chang-Heon; Kim, Min-Jae; Choi, Kwang-Soon; Jee, Kwang-Yong; Kim, Won-Ho

    2006-01-01

    Chemical characterization of various process materials is required for the optimization of the electrolytic reduction process in which uranium dioxide, a matrix of spent PWR fuels, is electrolytically reduced to uranium metal in a medium of LiCl-Li 2 O molten at 650 .deg. C. In the uranium metal ingots of interest in this study, residual process materials and corrosion products as well as fission products are involved to some extent, which further adds difficulties to the determination of trace fission products. Besides it, direct inductively coupled plasma atomic emission spectrometric (ICP-AES) analysis of uranium bearing materials such as the uranium metal ingots is not possible because a severe spectral interference is found in the intensely complex atomic emission spectra of uranium. Thus an adequate separation procedure for the fission products should be employed prior to their determinations. In present study ion exchange and extraction chromatographic methods were adopted for selective separation of the fission products from residual process materials, corrosion products and uranium matrix. The sorption behaviour of anion and tri-nbutylphosphate (TBP) extraction chromatographic resins for the metals in acidic solutions simulated for the uranium metal ingot solutions was investigated. Then the validity of the separation procedure for its reliability and applicability was evaluated by measuring recoveries of the metals added

  19. New Liquid Phases for the Gas Chromatographic Separation of Strong Bases on Capillary Columns

    OpenAIRE

    Grob, K.

    2017-01-01

    The current practice of pretreating the solid support with free alkali to increase separation efficiency for basic compounds proved to be unsuitable for capillary columns. Instead of this, homogenous organic materials of high base strength are required. We found polyethylene imine (PEI) and polypropylene imine (PPI) to be very efficient as liquid phases of capillary columns for the separation of bases. The preparation of polymers is mentioned. Silanization or acetylation of the free hydroxyl ...

  20. Direct coupling of a dense (supercritical) gas chromatograph to a mass spectrometer using a supersonic molecular beam interface

    International Nuclear Information System (INIS)

    Randall, L.G.; Wahrhaftig, A.L.

    1981-01-01

    A detecting mass spectrometer has been successfully coupled to a dense gas (supercritical fluid) chromatograph to produce an instrument (DGC/MS) that may be an alternative to high performance liquid chromatograph/mass spectrometer instruments (HPLC/MS) and gas chromatograph/mass spectrometer instruments (GC/MS) for analysis of involatile and/or thermally labile compounds. The mobile phase in DGC is a gas held at temperatures above the critical temperature and at pressures sufficient to obtain nearly liquid-like densities. DGC combines advantages of GC and HPLC: rapid separations, moderate operating temperatures, and analysis of involatile compounds. An advantage unique to DGC is the solvent power dependence upon pressure. While several groups have studied DGC, its development has been limited by the lack of a sensitive and selective detector. Hence, work has been directed towards the design and construction of a DGC/MS resulting in a trial instrument capable of chromatographic pressures of at least 300 atm and temperatures from 10 0 to 60 0 C. The DGC/MS coupling has been accomplished by the use of a supersonic molecular beam interface. This application of molecular beam formation appears to be unique in its requirements of a large pressure ratio (approx.10 8 ), low flow rates, and low final pressures. The authors outline characteristics of supersonic jets and molecular beams pertinent to the design of such an instrument. The interface which uses pumping speeds of 2400 and 1200 l/s in the beam forming chambers is described in detail, while the other components: the detecting mass spectrometer, the dense gas supply, and the DGC: are briefly described. Preliminary work with this instrument has established the feasibility of DGC/MS as an analytical technique and further development is recommended

  1. Separation of cations of heavy metalsfrom concentrated galvanic drains

    Directory of Open Access Journals (Sweden)

    L. P. Bondareva

    2018-01-01

    Full Text Available When applying galvanic coatings, soluble salts of heavy metals such as iron, copper, nickel, zinc, cadmium, chromium and other metals are used, toxic cations enter the water, with subsequent migration to the biosphere. To date, many methods have been developed for cleaning galvanic sewage, which cannot be considered sufficiently effective. The joint sorption of divalent cations of copper, nickel and cadmium from concentrated aqueous solutions was investigated. Calculation and experimental methods were used to determine the separation conditions of the bivalent ion systems that differed and close in sorption properties on the aminophosphonic polyampholyte Purolite S950 in a natrium form. It is shown that the cadmium (II cations can be isolated from solutions containing copper (II or nickel (II cations even at the height of the sorption layer of 0.13 m due to the difference in the defining characteristics of the cations. This layer height can be used not only in a chromatographic column, but also in a concentrating cartridge. Separation of the copper (II and nickel (II close to the sorption properties requires an absorbing layer of 0.76 m, which can only be used in a chromatographic column, but not for a concentrating cartridge. In this paper, the degrees of ion separation in various sorption conditions are calculated. The applicability of the conductometric method for controlling the ion exchange process is shown not only when the free cations are isolated from aqueous solutions but also bound to complexes.

  2. Separation of rare earth mixtures by gas chromatography using dipivaloylmethane as complexing agent

    International Nuclear Information System (INIS)

    Golubtsova, V.Yu.; Luchinkin, V.V.; Martynenko, L.I.; Murav'eva, I.A.; Sokolov, D.N.

    1981-01-01

    Possibility of using dipivaloylmethave for quantitative separation of rare earth element mixtures under the regime of chromatography for preparative and analytical purposes, is studied. Introduction of β-diketone surplus into the chromatographic solution is shown to remove the necessity of column conditioning. It is stated that chelate solution should have concentration above the threshold one. The developed method is applicable for quantitative separation of some rare earth mixtures for preparative purposes, as well as for the analysis of rare earth mixtures, containing components in equivalent quantities [ru

  3. New liquid chromatographic-chemometric approach for the determination of sunset yellow and tartrazine in commercial preparation.

    Science.gov (United States)

    Dinç, Erdal; Aktaş, A Hakan; Ustündağ, Ozgür

    2005-01-01

    A new liquid chromatographic (LC)-chemometric approach was developed for the determination of sunset yellow (SUN) and tartrazine (TAR) in commercial preparations. This approach uses LC and chemometric calibration methods, i.e., classical least-squares (CLS), principal component regression (PCR), and partial-least squares (PLS), simultaneously. The combined LC-chemometric approaches, denoted as LC-CLS, LC-PCR, and LC-PLS, are based on photodiode array (PDA) detection at multiple wavelengths. Optimum chromatographic separation of SUN and TAR with allura red as the internal standard (IS) was obtained by using a Waters Symmetry C18 column, 5 microm, 4.6 x 250 mm, and 0.2 M acetate buffer (pH 5)-acetonitrile-methano-bidistilled water (55 + 20 + 15 + 10, v/v) as the mobile phase at a flow rate of 1.9 mL/min. The LC data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using PDA detection at 5 wavelengths (465, 470, 475, 480, and 485 nm). LC-chemometric calibrations for SUN and TAR were separately constructed by using the relationship between the peak-area ratio and the training sets for each colorant. LC-chemometric approaches were tested for different synthetic mixtures containing SUN and TAR in the presence of the IS. These LC-chemometric calibrations were applied to a commercial preparation of the 2 colorants. The experimental results of the LC-chemometric approaches were compared with those obtained by a developed classical LC method using single-wavelength detection.

  4. Combined cation-exchange and extraction chromatographic method of pre-concentration and concomitant separation of Cu(II) with high molecular mass liquid cation exchanger after its online detection.

    Science.gov (United States)

    Mandal, B; Roy, U S; Datta, D; Ghosh, N

    2011-08-19

    A selective method has been developed for the extraction chromatographic trace level separation of Cu(II) with Versatic 10 (liquid cation exchanger) coated on silanised silica gel (SSG-V10). Cu(II) has been extracted from 0.1M acetate buffer at the range of pH 4.0-5.5. The effects of foreign ions, pH, flow-rate, stripping agents on extraction and elution have been investigated. Exchange capacity of the prepared exchanger at different temperatures with respect to Cu(II) has been determined. The extraction equilibrium constant (K(ex)) and different standard thermodynamic parameters have also been calculated by temperature variation method. Positive value of ΔH (7.98 kJ mol⁻¹) and ΔS (0.1916 kJ mol⁻¹) and negative value of ΔG (-49.16 kJ mol⁻¹) indicated that the process was endothermic, entropy gaining and spontaneous. Preconcentration factor was optimized at 74.7 ± 0.2 and the desorption constants K(desorption)¹(1.4 × 10⁻²) and K(desorption)²(9.8 × 10⁻²) were determined. The effect of pH on R(f) values in ion exchange paper chromatography has been investigated. In order to investigate the sorption isotherm, two equilibrium models, the Freundlich and Langmuir isotherms, were analyzed. Cu(II) has been separated from synthetic binary and multi-component mixtures containing various metal ions associated with it in ores and alloy samples. The method effectively permits sequential separation of Cu(II) from synthetic quaternary mixture containing its congeners Bi(III), Sn(II), Hg(II) and Cu(II), Cd(II), Pb(II) of same analytical group. The method was found effective for the selective detection, removal and recovery of Cu(II) from industrial waste and standard alloy samples following its preconcentration on the column. A plausible mechanism for the extraction of Cu(II) has been suggested. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Artificial neural network model for photosynthetic pigments identification using multi wavelength chromatographic data

    Science.gov (United States)

    Prilianti, K. R.; Hariyanto, S.; Natali, F. D. D.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2016-04-01

    The development of rapid and automatic pigment characterization method become an important issue due to the fact that there are only less than 1% of plant pigments in the earth have been explored. In this research, a mathematical model based on artificial intelligence approach was developed to simplify and accelerate pigment characterization process from HPLC (high-performance liquid chromatography) procedure. HPLC is a widely used technique to separate and identify pigments in a mixture. Input of the model is chromatographic data from HPLC device and output of the model is a list of pigments which is the spectrum pattern is discovered in it. This model provides two dimensional (retention time and wavelength) fingerprints for pigment characterization which is proven to be more accurate than one dimensional fingerprint (fixed wavelength). Moreover, by mimicking interconnection of the neuron in the nervous systems of the human brain, the model have learning ability that could be replacing expert judgement on evaluating spectrum pattern. In the preprocessing step, principal component analysis (PCA) was used to reduce the huge dimension of the chromatographic data. The aim of this step is to simplify the model and accelerate the identification process. Six photosynthetic pigments i.e. zeaxantin, pheophytin a, α-carotene, β-carotene, lycopene and lutein could be well identified by the model with accuracy up to 85.33% and processing time less than 1 second.

  6. Study on atmospheric hydrogen enrichment by cryopump method and isotope separation by gas chromatography

    International Nuclear Information System (INIS)

    Taniyama, Yuki; Momoshima, Noriyuki

    2001-01-01

    To obtain the information of source of atmospheric hydrogen tritium an analysis of tritium isotopes is thought to be effective. So an atmospheric hydrogen enrichment apparatus and a cryogenic gas chromatographic column were made. Experiments were carried out to study the performance of cryopump to enrich atmospheric hydrogen and the column to separate hydrogen isotopes that obtained by cryopump method. The cryopump was able to process about 1000 1 atmosphere and the column was able to separate hydrogen isotopes with good resolution. (author)

  7. Study on rare earths complexes separation by means of different type of ion exchangers

    International Nuclear Information System (INIS)

    Hubicka, H.

    1990-01-01

    The applicability of different types of ion exchangers for purification and separation of rare earths complexes has been examined. The experimental work has been carried out on 14 chelating ion exchangers. The investigation results proved the great usefulness chelating ion exchangers especially of amino acid and phosphorus-type. Application of that type ion exchangers in column chromatographic process gave the excellent rare earths separation as well as enabled to obtain their preparates of high purity. 218 refs, 21 figs, 27 tabs

  8. Reversed phase partition chromatographic separation of Gd(III) on poly(Crown Ether) column

    International Nuclear Information System (INIS)

    Mahanwar, K.R.; Sabale, S.R.

    2014-01-01

    A simple method has been developed for the separation of Gd(III) in hippuric acid medium by using poly(dibenzo-18-crown-6) as stationary phase. The effect of hippuric acid concentration, different eluting agent, foreign ions etc was studied and the optimum conditions were established. Breakthrough capacity of poly(dibenzo-18-crown-6) for Gd(III) was found to be 0.572 ±0.01 mmolg -1 of crown polymer. The separation of Gd(III) from other elements in multicomponent mixtures has been achieved. The method was extended for determination of Gd(III) in real sample. The method is simple, rapid and selective with good reproducibility (approximately ± 2%). Crown ethers are widely used as complexing agent that can selectively capture metal cation in their cavity. This special feature shown by poly (dibenzo-18-crown-6) has been used in our laboratory for selective cation exchanger by column chromatography. No attempts were made for the separation of Gd(III) using hippuric acid media and column chromatography. The present communication describes a simple and sensitive method for the determination of Gd(III) using poly(dibenzo-18-crown-6) as stationary phase in hippuric acid medium. The proposed method affords an attractive feature as compared to the solvent extraction technique i.e. it is free from any organic diluents as an environmental concern

  9. [Advances of poly (ionic liquid) materials in separation science].

    Science.gov (United States)

    Liu, Cuicui; Guo, Ting; Su, Rina; Gu, Yuchen; Deng, Qiliang

    2015-11-01

    Ionic liquids, as novel ionization reagents, possess beneficial characteristics including good solubility, conductivity, thermal stability, biocompatibility, low volatility and non-flammability. Ionic liquids are attracting a mass of attention of analytical chemists. Poly (ionic liquid) materials have common performances of ionic liquids and polymers, and have been successfully applied in separation science area. In this paper, we discuss the interaction mechanisms between the poly(ionic liquid) materials and analytes including hydrophobic/hydrophilic interactions, hydrogen bond, ion exchange, π-π stacking and electrostatic interactions, and summarize the application advances of the poly(ionic liquid) materials in solid phase extraction, chromatographic separation and capillary electrophoresis. At last, we describe the future prospect of poly(ionic liquid) materials.

  10. On-line gas chromatographic analysis of airborne particles

    Science.gov (United States)

    Hering, Susanne V [Berkeley, CA; Goldstein, Allen H [Orinda, CA

    2012-01-03

    A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.

  11. A Gas Chromatographic Continuous Emissions Monitoring System for the Determination of VOCs and HAPs.

    Science.gov (United States)

    Coleman, William M; Gordon, Bert M

    1996-01-01

    This article describes a new gas chromatography-based emissions monitoring system for measuring volatile organic compounds (VOCs) and hazardous air pollutants (HAPs). The system is composed of a dual-column gas chromatograph equipped with thermal conductivity detectors, in which separation is optimized for fast chromatography. The system has the necessary valving for stream selection, which allows automatic calibration of the system at predetermined times and successive measurement of individual VOCs before and after a control device. Nine different VOCs (two of which are HAPs), plus methane (CH4) and carbon dioxide (CO2) are separated and quantified every two minutes. The accuracy and precision of this system has been demonstrated to be greater than 95%. The system employs a mass flow measurement device and also calculates and displays processed emission data, such as control device efficiency and total weight emitted during given time periods. Two such systems have been operational for one year in two separate gravure printing facilities; minimal upkeep is required, about one hour per month. One of these systems, used before and after a carbon adsorber, has been approved by the pertinent local permitting authority.

  12. Gel chromatographic behavior of Tc-99m-labeled compounds in aqueous solution

    International Nuclear Information System (INIS)

    Suzuki, T.; Wagner, H.N. Jr.; Burns, H.D.; Dannals, F.F.

    1984-01-01

    The purpose of this study was to elucidate the interaction of Tc-99m-labeled compounds (Tc-99m 0/sub 4/-bar, Tc-99m glucoheptonate, Tc-99m DTPA, Tc-99m disofenin) with the chromatographic gels, to determine their relative molecular sizes and molecular structures in aqueous solution, which are based on their biomenbrane transport mechanism and quality control analysis. Each Tc-99m-labeled compound was eluted and analyzed by three different gel chromatrography systems varying buffers: Sephadex G-25, Sephadex LH-20 and Bio-Gel P-4. The best separation between the elution peaks of all compounds except Tc-99m glucoheptonate was achieved on Sephadex G-25 in methanol-0.025OM Tris-HCL buffer (pH 7.6) (1:1) which could avoid the aromatic interaction with the gels. Tc-99m glucoheptonate was well eluted only on a Bio-Gel P-4 column but its elution peak was not separated from other compounds' peaks. The elution of Tc-99m disofenin was delayed on Sephadex G-25 gel and Bio-Gel P-4 columns in 0.9% NaCl and Tris-HCl buffer(ph 7.6) and on Sephadex LH-20 column in methanol-Tris-HCl buffer, because of the aromatic ring interaction with the gels. The relative molecular size index ( Kav ) calculated from the elution volume of the gel chromatography. Kav of Tc-99m 0/sub 4/-bar(MW=163), Tc-99m DTPA (MW=492?) and TC-99m disofenin (MW=707) on Sephadex G-25 in methanol-0.025OM Tris-HCl buffer(pH 7.6) (1:1), which was the most suitable combination of the gel and the buffer, were 0.976, 0.477 and 0.200, respectively. They inversely correlated with their estimated molecular weight. The interaction of Tc-99m-labeled compounds with the chromatographic gels should be considered in quality control procedure for Tc-99m radiopharamaceuticals

  13. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  14. A charge-polarized porous metal-organic framework for gas chromatographic separation of alcohols from water.

    Science.gov (United States)

    Sun, Jian-Ke; Ji, Min; Chen, Cheng; Wang, Wu-Gen; Wang, Peng; Chen, Rui-Ping; Zhang, Jie

    2013-02-25

    A bipyridinium ligand with a charge separated skeleton has been introduced into a metal-organic framework to yield a porous material with charge-polarized pore space, which exhibits selective adsorption for polar guest molecules and can be further used in gas chromatography for the separation of alcohol-water mixtures.

  15. Analysis and chromatographic purification of eicosanoids multiply labeled by tritium

    International Nuclear Information System (INIS)

    Shevchenko, V.P.; Nagaev, I.Yu.; Myasoedov, N.F.

    1989-01-01

    We show the possibility of analysis and chromatographic purification of eicosanoids triply labeled by tritium. The described methods allow us to isolate chromatographically pure products obtained by selective hydrogenatin, chemical, and enzyme methods, with radiochemical purity at least 95-97%. The following methods are used to analyze the reaction mixtures and to isolate the tritium-labeled eicosanoids: gas-liquid chromatography, high-efficiency liquid chromatography, and thin-layer chromatography on supports impregnated with silver nitrate

  16. Separability by piecewise testable languages is PTime-complete

    Czech Academy of Sciences Publication Activity Database

    Masopust, Tomáš

    2018-01-01

    Roč. 711, February 8 (2018), s. 109-114 ISSN 0304-3975 Institutional support: RVO:67985840 Keywords : separability * piecewise testable languages * complexity Subject RIV: BA - General Mathematics OBOR OECD: Computer science s, information science , bioinformathics (hardware development to be 2.2, social aspect to be 5.8) Impact factor: 0.698, year: 2016 https://www. science direct.com/ science /article/pii/S0304397517308319?via%3Dihub

  17. Separability by piecewise testable languages is PTime-complete

    Czech Academy of Sciences Publication Activity Database

    Masopust, Tomáš

    2018-01-01

    Roč. 711, February 8 (2018), s. 109-114 ISSN 0304-3975 Institutional support: RVO:67985840 Keywords : separability * piecewise testable languages * complexity Subject RIV: BA - General Mathematics OBOR OECD: Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8) Impact factor: 0.698, year: 2016 https://www.sciencedirect.com/science/article/pii/S0304397517308319?via%3Dihub

  18. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    OpenAIRE

    Nataša Gros

    2013-01-01

    This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as com...

  19. New labeling and separation methods for in vivo and in vitro diagnostics in Hungary

    International Nuclear Information System (INIS)

    Veres, A.; Toth, G.; Zsinka, L.; Miller, J.

    1986-01-01

    Three methods have been developed: 1. An adsorption chromatographic method for the separation of iodine-125-labeled compounds applied as tracers in the radioimmunoassay; 2. A portable sublimation generator for the separation of technetium-99m from low or medium specific activity molybdenum-99 using titanium molybdate as a new target material; 3. A novel dry distillation method for the production of iodine-131 from melted, pile-irradiated TeO 2 . The method renders possible to get rid of liquid radioactive wastes. 1 reference

  20. Separation of uranium by extraction with foamed plastics

    International Nuclear Information System (INIS)

    Korkisch, J.

    1983-07-01

    Polyurethane foams are frequently used for the extraction and separation of inorganic and organic species. The attraction of the materials lies in their favourable hydrodynamic properties obviating the need for the forced-flow conditions associated with conventional chromatographic-type column packing of small particles. The research work described has been directed to providing information on the extraction and separation of uranium (and thorium) by an open-cell polyurethane foam from media containing nitrates and from hydrochloric acid systems. The influence of many different experimental parameters (concentrations, acidity, impregnation of the foam with organic extractants) on the extraction was investigated. Based on the results of these investigations two methods were developed to separate uranium from nitric acid solution and from hydrochloric acid solution, respectively. The first uses calcium or aluminium nitrate salting and foam impregnated with Aliquat 336, the second ascorbic acid addition and TOPO-impregnated foam. The methods separate uranium and thorium from each other and from most other elements and can be used analytically or in the purification of uranium from impure plant products such as yellow cake

  1. Preparation of chromatographic and solid-solvent extraction 99mTc generators using gel-type targets

    International Nuclear Information System (INIS)

    Le Van So

    2000-01-01

    We have studied two types of targets zirconium-molybdate (ZrMo) and titanium-molybdate (TiMo) prepared by precipitating reaction between ammonium-molybdate and zirconium-chloride or titanium-chloride solutions, respectively. Other types of targets were also prepared by co-precipitating ZrMo or TiMo with hydrous manganese-dioxide, hydrous silica, and hydrous titanium-dioxide or by impregnated ZrMo or TiMo with Iodate anions. The results on extraction of Tc-99m from neutron irradiated TiMo solid phase using solvents such as MEK, aceton, ethylic ether, chloroform, etc showed that separation yield (SY) of Tc-99m in case of aceton extraction was from 70% to 80% and in other cases non higher than 40%. The Tc-99m elution curves and column kinetic in case of aceton extraction (after evaporation of aceton and recovery of Tc-99m in 0,9% NaCl solution) was superior than in case chromatographic generator using saline eluant. As result obtained, two types of generators were successfully prepared and put into use: Chromatographic generator using titanium-molybdate target as packing material and saline as eluant. Solid-solvent extraction 99m Tc generator using titanium-molybdate target (as solid phase) and aceton as extracting solvent. (author)

  2. Review of UV spectroscopic, chromatographic, and electrophoretic methods for the cholinesterase reactivating antidote pralidoxime (2-PAM).

    Science.gov (United States)

    John, Harald; Blum, Marc-Michael

    2012-01-01

    Pralidoxime (2-PAM) belongs to the class of monopyridinium oximes with reactivating potency on cholinesterases inhibited by phosphylating organophosphorus compounds (OPC), for example, pesticides and nerve agents. 2-PAM represents an established antidote for the therapy of anticholinesterase poisoning since the late 1950s. Quite high therapeutic concentrations in human plasma (about 13 µg/ml) lead to concentrations in urine being about 100 times higher allowing the use of less sensitive analytical techniques that were used especially in the early years after 2-PAM was introduced. In this time (mid-1950s until the end of the 1970s) 2-PAM was most often analyzed by either paper chromatography or simple UV spectroscopic techniques omitting any sample separation step. These methods were displaced completely after the establishment of column liquid chromatography in the early 1980s. Since then, diverse techniques including cation exchange, size-exclusion, reversed-phase, and ligand-exchange chromatography have been introduced. Today, the most popular method for 2-PAM quantification is ion pair chromatography often combined with UV detection representing more than 50% of all column chromatographic procedures published. Furthermore, electrophoretic approaches by paper and capillary zone electrophoresis have been successfully used but are seldom applied. This review provides a commentary and exhaustive summary of analytical techniques applied to detect 2-PAM in pharmaceutical formulations and biological samples to characterize stability and pharmacokinetics as well as decomposition and biotransformation products. Separation techniques as well as diverse detectors are discussed in appropriate detail allowing comparison of individual preferences and limitations. In addition, novel data on mass spectrometric fragmentation of 2-PAM are provided. Copyright © 2011 John Wiley & Sons, Ltd.

  3. A new system for complete separation of 3He and T2 composed of a falling liquid film condenser and a cryogenic distillation column with a feedback stream

    International Nuclear Information System (INIS)

    Kinoshita, Masahiro; Bartlit, J.R.; Sherman, R.H.

    1982-11-01

    A new system composed of a falling liquid film condenser and a cryogenic distillation column with a feedback stream, is developed for complete separation of 3 He and T 2 . For accomplishment of the separation, a sufficient flow rate of protium is added to the feed mixture. The resultant stream of 3 He, H 2 , HT and T 2 is fed to the falling liquid film condenser, and 3 He is removed almost completely. The H-T mixture from the bottom of the falling liquid film condenser is further processed by the cryogenic distillation column for complete separation of protium and tritium. The tritium recovery percentage of the system is 100%, and the two top streams can be transferred to a tritium waste treatment system. (author)

  4. Use of a macrocyclic antibiotic as the chiral selector for enantiomeric separations by TLC

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, D.W.; Zhou, Y. (Univ. of Missouri, Rolla, MO (United States). Dept. of Chemistry)

    1994-01-01

    The macrocyclic antibiotic, vancomycin, was used as a chiral mobile phase additive for the thin layer chromatographic (TLC) resolution of 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) derivatized amino acids, racemic drugs and dansyl-amino acids. Excellent separations were achieved for most of these compounds in the reversed phase mode. Both the nature of the stationary phase and the composition of the mobile phase strongly influenced enantiomeric resolution. The best results were obtained using diphenyl stationary phases. Acetonitrile was the organic modifier that produced the most effective separations with the shortest development times. It is highly likely that macrocyclic antibiotics will play a major role in future enantiomeric separations.

  5. Separation of tungsten from molybdenum by liquid-liquid extraction and extraction chromatography using thiocyanate and a quarternary ammonium salt

    International Nuclear Information System (INIS)

    Yonezawa, C.; Onishi, H.

    1977-01-01

    Methods were developed for the separation of tungsten from molybdenum by liquid-liquid extraction and extraction chromatography using thiocyanate and a quaternary ammonium salt, Zephiramine. Tungsten was extracted into chloroform as an ion associate of tungsten(V)-thiocyanate complex and Zephiramine cation was retained on a column of Teflon powder coated with Zephiramine, but molybdenum(III) was neither extracted nor retained. The extraction chromatographic method was succesfully applied to the determination of trace amounts of tungsten in molybdenum by neutron activation analysis. The γ-ray spectrum, observed with the Ge(Li) detector, of tungsten fraction separated from irradiated molybdenum are shown. The peaks of 99 Mo, sup(99m)Tc, and sup(99m)Nb (produced by 92 Mo(n,p)sup(99m)Nb) were seen, but these nuclides did nit interfere with the determination of tungsten using a NaI(Tl) detector. The results of the neutron activation analysis of a sample of ammonium molybdate agreed quite well with that of the spectrophotometric determination after extraction chromatographic separation. (T.G.)

  6. Triticonazole enantiomers: Separation by supercritical fluid chromatography and the effect of the chromatographic conditions.

    Science.gov (United States)

    He, Jianfeng; Fan, Jun; Yan, Yilun; Chen, Xiaodong; Wang, Tai; Zhang, Yaomou; Zhang, Weiguang

    2016-11-01

    Enantiomeric pairs of triticonazole have been successfully separated by supercritical fluid chromatography coupled with a tris(3,5-dimethylphenylcarbamoyl) cellulose-coated chiral stationary phase in this work. The effects of co-solvent, dissolution solvent, flow rate, backpressure, and column temperature have been studied in detail with respect to retention, selectivity, and resolution of triticonazole. As indicated, the co-solvents mostly affected the retention factors and resolution, due to the different molecular structure and polarity. In addition, the dissolution solvents, namely, chloromethanes and alcohols, have been also important for enantioseparation because of the different interaction with stationary phase. Higher flow rate and backpressure led to faster elution of the triticonazole molecules, and the change of column temperature showed slight effect on the resolution of triticonazole racemate. Moreover, a comparative separation experiment between supercritical fluid chromatography and high performance liquid chromatography revealed that chiral supercritical fluid chromatography gave the 3.5 times value of R s /t R2 than high performance liquid chromatography, which demonstrated that supercritical fluid chromatography had much higher separation efficiency. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Separation of multiphosphorylated peptide isomers by hydrophilic interaction chromatography on an aminopropyl phase.

    Science.gov (United States)

    Singer, David; Kuhlmann, Julia; Muschket, Matthias; Hoffmann, Ralf

    2010-08-01

    The separation of isomeric phosphorylated peptides is challenging and often impossible for multiphosphorylated isomers using chromatographic and capillary electrophoretic methods. In this study we investigated the separation of a set of single-, double-, and triple-phosphorylated peptides (corresponding to the human tau protein) by ion-pair reversed-phase chromatography (IP-RPC) and hydrophilic interaction chromatography (HILIC). In HILIC both hydroxyl and aminopropyl stationary phases were tested with aqueous acetonitrile in order to assess their separation efficiency. The hydroxyl phase separated the phosphopeptides very well from the unphosphorylated analogue, while on the aminopropyl phase even isomeric phosphopeptides attained baseline separation. Thus, up to seven phosphorylated versions of a given tau domain were separated. Furthermore, the low concentration of an acidic ammonium formate buffer allowed an online analysis with electrospray ionization tandem mass spectrometry (ESI-MS/MS) to be conducted, enabling peptide sequencing and identification of phosphorylation sites.

  8. Investigations into polymer and carbon nanomaterial separations

    Science.gov (United States)

    Owens, Cherie Nicole

    The work of this thesis follows a common theme of research focused on innovative separation science. Polyhydroxyalkanoates are biodegradable polyesters produced by bacteria that can have a wide distribution in molecular weight and monomer composition. This large distribution often leads to unpredictable physical properties making commercial applications challenging. To improve polymer homogeneity and obtain samples with a clear set of physical characteristics, poly-3-hydroxyvalerate-co-3-hydroxybutyrate copolymers were fractionated using gradient polymer elution chromatography (GPEC) with carefully optimized gradients. The resulting fractions were analyzed using Size Exclusion Chromatography (SEC) and NMR. As the percentage of “good” solvent was increased in the mobile phase, the polymers eluted with decreasing percentage of 3-hydroxyvalerate and increasing molecular weight, which indicates the importance of precipitation/redissolution in the separation. As such, GPEC is an excellent choice to provide polyhydroxyalkanoate samples with a narrower distribution in composition than the original bulk copolymer. Additionally, the critical condition was found for 3-hydroxybutyrate to erase its effects on retention of the copolymer. Copolymer samples were then separated using Liquid Chromatography at the Critical Condition (LCCC) and it was determined that poly(3-hydroxvalerate-co-3-hydroxybutyrate) is a statistically random copolymer. The second project uses ultra-thin layer chromatography (UTLC) to study the performance and behavior of polyhydroxybutyrate (P3HB) as a chromatographic substrate. One specific polyhydroxyalkanoate, polyhydroxybutyrate, is a liquid crystalline polymer that can be electrospun. Electrospinning involves the formation of nanofibers though the application of an electric potential to a polymer solution. Precisely controlled optimization of electrospinning parameters was conducted to achieve the smallest diameter PHA nanofibers to date to

  9. Dentate gyrus supports slope recognition memory, shades of grey-context pattern separation and recognition memory, and CA3 supports pattern completion for object memory.

    Science.gov (United States)

    Kesner, Raymond P; Kirk, Ryan A; Yu, Zhenghui; Polansky, Caitlin; Musso, Nick D

    2016-03-01

    In order to examine the role of the dorsal dentate gyrus (dDG) in slope (vertical space) recognition and possible pattern separation, various slope (vertical space) degrees were used in a novel exploratory paradigm to measure novelty detection for changes in slope (vertical space) recognition memory and slope memory pattern separation in Experiment 1. The results of the experiment indicate that control rats displayed a slope recognition memory function with a pattern separation process for slope memory that is dependent upon the magnitude of change in slope between study and test phases. In contrast, the dDG lesioned rats displayed an impairment in slope recognition memory, though because there was no significant interaction between the two groups and slope memory, a reliable pattern separation impairment for slope could not be firmly established in the DG lesioned rats. In Experiment 2, in order to determine whether, the dDG plays a role in shades of grey spatial context recognition and possible pattern separation, shades of grey were used in a novel exploratory paradigm to measure novelty detection for changes in the shades of grey context environment. The results of the experiment indicate that control rats displayed a shades of grey-context pattern separation effect across levels of separation of context (shades of grey). In contrast, the DG lesioned rats displayed a significant interaction between the two groups and levels of shades of grey suggesting impairment in a pattern separation function for levels of shades of grey. In Experiment 3 in order to determine whether the dorsal CA3 (dCA3) plays a role in object pattern completion, a new task requiring less training and using a choice that was based on choosing the correct set of objects on a two-choice discrimination task was used. The results indicated that control rats displayed a pattern completion function based on the availability of one, two, three or four cues. In contrast, the dCA3 lesioned rats

  10. Different Chromatographic Methods for Simultaneous Determination of Mefenamic Acid and Two of Its Toxic Impurities.

    Science.gov (United States)

    Morcoss, Martha M; Abdelwahab, Nada S; Ali, Nouruddin W; Elsaady, Mohammed T

    2017-08-01

    Two sensitive, accurate and precise chromatographic methods mentioned as TLC-densitometric method and RP-HPLC-DAD method, were developed and validated for the simultaneous determination of mefenamic acid (MEF) and its two toxic impurities, benzoic acid (BA) and 2,3-dimethylaniline (DMA). In the proposed TLC-densitometric method a developing system consisting of chloroform:acetone:acetic acid:ammonia solution(70:30:2:2, v/v/v/v) was used, TLC aluminum plates 60 F254 was used as a stationary phase and the separated bands were UV-scanned at 225 nm. While the proposed RP-HPLC-DAD method depended on chromatographic separation on C18 column using 0.05 M KH2PO4 buffer: acetonitrile (40:60, v/v) as a mobile phase at constant flow rate of 1 mL/min with UV detection at 225 nm. Linear relationships were obtained in the ranges of 0.3-2, 0.3-2 and 0.3-1.8 μg/band (for TLC-densitometric method) and in the ranges of 7-50, 10-50 and 7-50 μg/mL (for HPLC-DAD method) for MEF, BA and DMA, respectively. Factors affecting the developed methods have been studied and optimized. Moreover ,the proposed methods were successfully applied for determination of the studied drug in its pharmaceutical dosage form. The methods showed no significance difference when compared with the reported method using F-test and Student's-t test. The low of detection and quantization limits of the proposed methods get them suitable for quality control and stability studies of MEF in pharmaceutical formulation. The developed methods have advantages of being more selective and sensitive than the published methods. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Preparation and separation of the glucuronide and sulfate conjugates of thyroxine and triiodothyronine

    International Nuclear Information System (INIS)

    Hays, M.T.; Hsu, L.

    1987-01-01

    An enzymatic method for synthesis of labelled thyroxine glucuronide (T4G) and triiodothyronine glucuronide (T3G) from labelled thyroxine (T4) and triiodothyronine (T3) is presented. The synthetic glucuronides are completely digested by beta-glucuronidase, with recovery of the parent T4 or T3. They have distinctive elution patterns on HPLC and on Sephadex G25 chromatography, and can be clearly separated from T4 and T3 as well as from synthetic T4 sulfate (T4S) and T3 sulfate (T3S). On LH 20 chromatography, elution of T4G and T3G is intermediate between that of T4 and T3 and that of T4S and T3S. T3G can be well separated from other thyronines by HPLC alone, but T4G coelutes with rT3 on HPLC; these are then separated by adding a Sephadex G25 chromatography step. Biosynthetic 131 I-T3G and 125 I-T4G from the bile of a cat given 131 I-T3 and 125 I-T4 had similar HPLC chromatographic patterns to those of synthetic T3G and T4G. That the identified peaks from analysis of the bile were indeed T3G and T4G was confirmed by recovery of the parent T3 and T4 after beta-glucuronidase digestion

  12. [Ideas and methods of two-dimensional zebrafish model combined with chromatographic techniques in high-throughput screening of active anti-osteoporosis components of traditional Chinese medicines].

    Science.gov (United States)

    Wei, Ying-Jie; Jing, Li-Jun; Zhan, Yang; Sun, E; Jia, Xiao-Bin

    2014-05-01

    To break through the restrictions of the evaluation model and the quantity of compounds by using the two-dimensional zebrafish model combined with chromatographic techniques, and establish a new method for the high-throughput screening of active anti-osteoporosis components. According to the research group-related studies and relevant foreign literatures, on the basis of the fact that the zebrafish osteoporosis model could efficiently evaluate the activity, the zebrafish metabolism model could efficiently enrich metabolites and the chromatographic techniques could efficiently separate and analyze components of traditional Chinese medicines, we proposed that the inherent combination of the three methods is expected to efficiently decode in vivo and in vitro efficacious anti-osteoporosis materials of traditional Chinese medicines. The method makes it simple and efficient in the enrichment, separation and analysis on components of traditional Chinese medicines, particularly micro-components and metabolites and the screening anti-osteoporosis activity, fully reflects that efficacious materials of traditional Chinese medicines contain original components and metabolites, with characteristic of "multi-components, multi-targets and integral effect", which provides new ideas and methods for the early and rapid discovery of active anti-osteoporosis components of traditional Chinese medicines.

  13. High-pressure liquid chromatographic assay of Bay n 7133 in human serum.

    OpenAIRE

    Fasching, C E; Hughes, C E; Hector, R F; Peterson, L R

    1984-01-01

    A high-pressure liquid chromatographic method that includes a Sep-Pak (Waters Associates, Inc., Milford , Mass.) preparation of human serum was employed for the quantitative assay of Bay n 7133. Drug levels of 0.1 to 20 micrograms/ml could be detected. No interference from amphotericin B was found in the chromatographic analysis of Bay n 7133.

  14. Pyrolysis gas chromatographic atomic emission detection for sediments, coals and other petrochemical precursors

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, J.A.; Zeng, Y.D.; Uden, P.C.; Eglinton, T.I.; Ericson, I. (Massachusetts University, Amherst, MA (USA). Dept. of Chemistry)

    1992-09-01

    On-line flash pyrolysis coupled to a capillary gas chromatograph for the characterization of marine sediments, coals and other heterogeneous solid samples is described. A helium microwave-induced plasma is used for chromatographic detection by atomic emission spectrometry. Simultaneous multi-element detection is achieved with a photodiode array detector. The optical path of the gas chromatographic atomic emission detector is purged with helium, allowing simultaneous, sensitive detection of atomic emission from sulfur 181 nm, phosphorous 186 nm, arsenic 189 nm, selenium 196 nm and carbon 193 nm. Several sediment and coal samples have been analysed for their carbon, nitrogen, sulfur, oxygen, phosphorous, arsenic and selenium content. Qualitative information indicating the occurrence and distribution of these elements in the samples can be used to gauge the relative stage of diagenetic evolution of the samples and provide information on their depositional environment. In some instances the chromatographic behaviour of the compounds produced upon pyrolysis is improved through on-line alkylation. This on-line derivatization is achieved by adding liquid reagents to the pyrolysis probe or by adding liquid reagents to the pyrolysis probe or by adding solid reagents either to the solid sample or by packing the reagent in the injection port of the chromatograph.

  15. Study of interactions between lanthanides/actinides and humic substances by a steric exclusion chromatographic method

    International Nuclear Information System (INIS)

    Moulin, V.

    1986-01-01

    The knowledge of cation-humic matter interactions has a great importance in order to have a better understanding of the contribution of these substances to the possible transport of radioactive elements in the geosphere via groundwaters. The method chosen to study the formation of soluble species between lanthanides/actinides ions and humic acids from different origins is a chromatographic technique of gel filtration. This dynamic equilibrium method is based on the separation of the formed complex and the free cation by the porous packing gel. Different elements have been studied by this method: UO 2 2+ , Eu 3+ , Th 4+ and global interaction constants have been calculated. The application to transuranic elements is undertaken. (orig.)

  16. Inorganic ion-exchangers. Their role in chromatographic radionuclide generators for the decade 1993-2002

    International Nuclear Information System (INIS)

    Mushtaq, A.

    2004-01-01

    Ion-exchangers are found not only in water purification processes, the original major application, but also in analytical chemistry for the separation and isolation of elements, hydrometallurgy, inorganic chemistry and biochemistry, in food technology, and of course in many specialized fields related to the utilization of atomic energy. The use of organic ion-exchangers is limited by virtue of their limited stability under harsh conditions, whereas inorganic ion-exchangers possess important properties, which make them very useful for chemical separation and purification in intense radiation fields. The availability of short-lived radionuclides from radionuclide generators provides an inexpensive and convenient alternative to in-house radioisotope production facilities such as accelerators and cyclotrons. Due to their simplicity of operation, chromatographic based generators have been the method of choice, although generators based on solvent extraction and on volatilization and sublimation have also been developed, and are routinely used. In this paper use of inorganic ion-exchangers for the development of radionuclide generators for the decade 1993-2002 has been compiled. (author)

  17. Chromatographic background drift correction coupled with parallel factor analysis to resolve coelution problems in three-dimensional chromatographic data: quantification of eleven antibiotics in tap water samples by high-performance liquid chromatography coupled with a diode array detector.

    Science.gov (United States)

    Yu, Yong-Jie; Wu, Hai-Long; Fu, Hai-Yan; Zhao, Juan; Li, Yuan-Na; Li, Shu-Fang; Kang, Chao; Yu, Ru-Qin

    2013-08-09

    Chromatographic background drift correction has been an important field of research in chromatographic analysis. In the present work, orthogonal spectral space projection for background drift correction of three-dimensional chromatographic data was described in detail and combined with parallel factor analysis (PARAFAC) to resolve overlapped chromatographic peaks and obtain the second-order advantage. This strategy was verified by simulated chromatographic data and afforded significant improvement in quantitative results. Finally, this strategy was successfully utilized to quantify eleven antibiotics in tap water samples. Compared with the traditional methodology of introducing excessive factors for the PARAFAC model to eliminate the effect of background drift, clear improvement in the quantitative performance of PARAFAC was observed after background drift correction by orthogonal spectral space projection. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Development of an on-line size exclusion chromatographic - reversed-phase liquid chromatographic two-dimensional system for the quantitative determination of peptides with concentration prior to reversed-phase liquid chromatographic separation

    NARCIS (Netherlands)

    Stroink, T.; Wiese, G.; Lingeman, H.; Bult, A.; Underberg, W.J.M.

    2001-01-01

    Complex samples, containing endogenous peptides require analytical methods with high sensitivity and selectivity to enable reliable analysis of these compounds in biological samples. In a number of cases, the selectivity of mono-dimensional separation systems is not sufficient. In order to improve

  19. Porous polymer monoliths functionalized through copolymerization of a C60 fullerene-containing methacrylate monomer for highly efficient separations of small molecules

    KAUST Repository

    Chambers, Stuart D.; Holcombe, Thomas W.; Švec, František; Frechet, Jean

    2011-01-01

    been prepared and their chromatographic performance have been tested for the separation of small molecules in the reversed phase. While addition of the C60-fullerene monomer to the glycidyl methacrylate-based monolith enhanced column efficiency 18-fold

  20. Validação em métodos cromatográficos e eletroforéticos Validation for chromatographic and electrophoretic methods

    Directory of Open Access Journals (Sweden)

    Marcelo Ribani

    2004-10-01

    Full Text Available The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the different Brazilian and international regulatory agencies.

  1. Chromatographic determination of silicon and phosphorus as molybdic heteropoly acids with preconcentration

    International Nuclear Information System (INIS)

    Tikhomirova, T.I.; Krokhin, O.V.; Dubovik, D.B.; Ivanov, A.V.; Shpigun, O.A.

    2002-01-01

    Chromatographic behaviour of silicon and phosphorus as molybdic heteropoly acids with preconcentration as ion associations of heteropoly acid with tributylammonium bromide was studied. The technique of simultaneous analysis of silicon and phosphorus was developed. During investigation into the effect of acetonitril content in the probe on the form of chromatographic peak of molybdosilicic acid the negative influence of acetonitril on the form of peak was ascertained. This effect may be eliminated by the lowering of acetonitril content up to 50 %. It was found that under these conditions the chromatographic peak practically was absent, because of the heteropoly acid of the Mo(VI) abundance transformed in the MoO 2 2+ cation form without reaction with tributylammonium cation during concentration of heteropoly acid [ru

  2. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    Science.gov (United States)

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  3. The behaviour of radionuclides in gas adsorption chromatographic processes with superimposed chemical reactions (chlorides)

    International Nuclear Information System (INIS)

    Eichler, B.

    1996-01-01

    Thermochemical relationships are derived describing the gas adsorption chromatographic transport of carrier-free radionuclides. Especially, complex adsorption processes such as dissociative, associative and substitutive adsorption are dealt with. The comparison of experimental with calculated data allows the determination of the type of adsorption reaction, which is the basis of the respective gas chromatographic process. The behaviour of carrier-free radionuclides of elements Pu, Ce, Ru, Co and Cr in thermochromatographic experiments with chlorinating carrier gases can be described as dissociative adsorption of chlorides in higher oxidation states. The gas adsorption chromatographic transport of Zr with oxygen and chlorine containing carrier gas is shown to be a substitutive adsorption process. The consequences of superimposed chemical reactions on the interpretation of results and the conception of gas adsorption chromatographic experiments with carrier-free radionuclides in isothermal columns and in temperature gradient tubes is discussed. (orig.)

  4. Sb(III) and Sb(V) separation and analytical speciation by a continuous tandem on-line separation device in connection with inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Menendez Garcia, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Perez Rodriguez, M.C. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanchez Uria, J.F. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanz-Medel, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.

    1995-09-01

    A sensitive, precise and automated non-chromatographic method for Sb(III) and Sb(V) analytical speciation based on a continuous tandem on-line separation device in connection with inductively coupled plasma-atomic emission (ICP-AES) detection is proposed. Two on-line successive separation steps are included into this method: a continuous liquid-liquid extraction of Sb(III) with ammonium pyrrolidine dithiocarbamate (APDC) into methylisobuthylketone (MIBK), followed by direct stibine generation from the organic phase. Both separation steps are carried out in a continuous mode and on-line with the ICP-AES detector. Optimization of experimental conditions for the tandem separation and ICP-AES detection are investigated in detail. Detection limits for Sb(III) were 3 ng.mL{sup -1} and for Sb(V) 8 ng.mL{sup -1}. Precisions observed are in the range {+-} 5%. The proposed methodology has been applied to Sb(III) and Sb(V) speciation in sea-water samples. (orig.)

  5. Chromatographic characterisation, in vitro antioxidant and free ...

    African Journals Online (AJOL)

    Chromatographic fractionation and spectroscopic analysis of the ME4 fraction revealed the presence of four compounds namely garcinia biflavonoids GB1 and GB2, garcinal and garcinoic acid. These findings show that these four compounds are partly responsible for the great antioxidant potential of G. kola seeds.

  6. Two-dimensional preparative liquid chromatography system for preparative separation of minor amount components from complicated natural products

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Ying-Kun, E-mail: qyk@xmu.edu.cn; Chen, Fang-Fang; Zhang, Ling-Ling; Yan, Xia; Chen, Lin; Fang, Mei-Juan; Wu, Zhen, E-mail: wuzhen@xmu.edu.cn

    2014-04-01

    Highlights: • Preparative MDLC system was developed for separation of complicated natural products. • Medium-pressure LC and preparative HPLC were connected by interface of SPE. • Automated multi-step preparative separation of 25 compounds was achieved by using this system. - Abstract: An on-line comprehensive two-dimensional preparative liquid chromatography system was developed for preparative separation of minor amount components from complicated natural products. Medium-pressure liquid chromatograph (MPLC) was applied as the first dimension and preparative HPLC as the second one, in conjunction with trapping column and makeup pump. The performance of the trapping column was evaluated, in terms of column size, dilution ratio and diameter-height ratio, as well as system pressure from the view of medium pressure liquid chromatograph. Satisfactory trapping efficiency can be achieved using a commercially available 15 mm × 30 mm i.d. ODS pre-column. The instrument operation and the performance of this MPLC × preparative HPLC system were illustrated by gram-scale isolation of crude macro-porous resin enriched water extract of Rheum hotaoense. Automated multi-step preparative separation of 25 compounds, whose structures were identified by MS, {sup 1}H NMR and even by less-sensitive {sup 13}C NMR, could be achieved in a short period of time using this system, exhibiting great advantages in analytical efficiency and sample treatment capacity compared with conventional methods.

  7. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  8. Search for chemical separations of the element 106 homologues in HF and HF-HCl media

    International Nuclear Information System (INIS)

    Trubert, D.; Monroy-Guzman, F.; Hussonnois, M.; Brillard, L.; Le Naour, C.; Constantinescu, O.

    1996-01-01

    In order to study the chemical properties of element 263 106 in aqueous media, fast, efficient and reproducible chromatographic separations were tested on its assumed homologous: Mo, W and U. Corroborative static and dynamic off-line experiments have shown that after fixation of these three elements on anion-exchange resin in HF medium, selective elution could be achieved by using suitable concentration of HCl - HF and HCl solutions. Separations of short-lived W isotopes, produced through heavy ion irradiation were also performed on-line. (author). 27 refs., 14 figs

  9. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    Directory of Open Access Journals (Sweden)

    Sonia T. Hassib

    2011-12-01

    Full Text Available Simple, accurate and precise reversed-phase liquid chromatographic (LC and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS and trimethoprim (TMP in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9:acetonitrile:water (25:100:50, v/v/v at a flow rate of 1.6 ml min−1 with UV detection at 210 nm for ERS and 280 nm for TMP. Besides, two spectrophotometric methods were applied after reaction with perchloric acid (12 M which gives a colored product with ERS. Then, the spectral interference between the colored product of ERS and TMP was resolved by either ratio spectra derivative spectrophotometry in the first spectrophotometric method or chemometric techniques, namely classical least-squares (CLS, principal component regression (PCR and partial least-squares regression (PLS in the second spectrophotometric method. The results were statistically compared using one-way analysis of variance (ANOVA. The methods developed were satisfactorily applied to the analysis of the pharmaceutical preparation containing the two drugs and proved to be specific and accurate for the quality control of the cited drugs in pharmaceutical dosage forms.

  10. Uses of extraction and ion exchange chromatography in the thorium and rare earths separation from industrial residue generated in thorium purification unity at IPEN. Application of rare earths as catalysts for generation of hydrogen

    International Nuclear Information System (INIS)

    Zini, Josiane

    2010-01-01

    In the 70's a pilot plant for studies of different concentrates processing obtained from the chemical processing of monazite was operated at IPEN / CNEN-SP, with a view to obtaining thorium of nuclear purity. This unity was operated on an industrial scale since 1985, generating around 25 metric tons of residue and was closed in 2002. This waste containing thorium and rare earths was named Retoter (Rejeito de Torio e Terras Raras, in portuguese) and stored in the IPEN Safeguards shed. This paper studies the treatment of the waste, aimed at environmental, radiological and technology. Were studied two cases for the chromatographic separation of thorium from rare earths. One of them was the chromatographic extraction, where the extracting agent tributyl phosphate was supported on polymeric resins Amberlite XAD16. The other method is studied for comparison purposes, since the material used in chromatographic extraction is unprecedented with regard to the separation of thorium, was the ion-exchange chromatography using DOWEX 1-X8 strong cationic resin. Was studied also the chromatographic process of extraction with the extracting agent DEHPA supported on Amberlite XAD16 for the fractionation in groups of rare earths elements. Thorium was separated with high purity for strategic purposes and rare earths recovered free from thorium, were tested as a catalyst for ethanol reforming to hydrogen obtaining which is used in fuel cells for power generation. (author)

  11. Validated high performance liquid chromatographic (HPLC) method ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-22

    Feb 22, 2010 ... specific and accurate high performance liquid chromatographic method for determination of ZER in micro-volumes ... tional medicine as a cure for swelling, sores, loss of appetite and ... Receptor Activator for Nuclear Factor κ B Ligand .... The effect of ... be suitable for preclinical pharmacokinetic studies. The.

  12. Chiral separation of a diketopiperazine pheromone from marine diatoms using supercritical fluid chromatography.

    Science.gov (United States)

    Frenkel, Johannes; Wess, Carsten; Vyverman, Wim; Pohnert, Georg

    2014-03-01

    The proline derived diketopiperazine has been identified in plants, insects and fungi with unknown function and was recently also reported as the first pheromone from a diatom. Nevertheless the stereochemistry and enantiomeric excess of this natural product remained inaccessible using direct analytical methods. Here we introduce a chiral separation of this metabolite using supercritical fluid chromatography/mass spectrometry. Several chromatographic methods for chiral analysis of the diketopiperazine from the diatom Seminavis robusta and synthetic enantiomers have been evaluated but neither gas chromatography nor high performance liquid chromatography on different chiral cyclodextrin phases were successful in separating the enantiomers. In contrast, supercritical fluid chromatography achieved baseline separation within four minutes of run time using amylose tris(3,5-dimethylphenylcarbamate) as stationary phase and 2-propanol/CO2 as mobile phase. This very rapid chromatographic method in combination with ESI mass spectrometry allowed the direct analysis of the cyclic dipeptide out of the complex sea water matrix after SPE enrichment. The method could be used to determine the enantiomeric excess of freshly released pheromone and to follow the rapid degradation observed in diatom cultures. Initially only trace amounts of c(d-Pro-d-Pro) were found besides the dominant c(l-Pro-l-Pro) in the medium. However the enantiomeric excess decreased upon pheromone degradation within few hours indicating that a preferential conversion and thus inactivation of the l-proline derived natural product takes place. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Simultaneous separation and analysis of water- and fat-soluble vitamins on multi-modal reversed-phase weak anion exchange material by HPLC-UV.

    Science.gov (United States)

    Dabre, Romain; Azad, Nazanin; Schwämmle, Achim; Lämmerhofer, Michael; Lindner, Wolfgang

    2011-04-01

    Several methods for the separation of vitamins on HPLC columns were already validated in the last 20 years. However, most of the techniques focus on separating either fat- or water-soluble vitamins and only few methods are intended to separate lipophilic and hydrophilic vitamins simultaneously. A mixed-mode reversed-phase weak anion exchange (RP-WAX) stationary phase was developed in our laboratory in order to address such mixture of analytes with different chemical characteristics, which are difficult to separate on standard columns. The high versatility in usage of the RP-WAX chromatographic material allowed a baseline separation of ten vitamins within a single run, seven water-soluble and three fat-soluble, using three different chromatographic modes: some positively charged vitamins are eluted in ion exclusion and ion repulsion modes whereas the negatively charged molecules are eluted in the ion exchange mechanism. The non-charged molecules are eluted in a classical reversed-phase mode, regarding their polarities. The method was validated for the vitamin analysis in tablets, evaluating selectivity, robustness, linearity, accuracy, and precision. The validated method was finally employed for the analysis of the vitamin content of some commercially available supplement tablets. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Separation of the stereoisomers of the main metabolite of a non-steroidal anti-inflammatory drug, flobufen, by chiral high-performance liquid chromatography.

    Science.gov (United States)

    Wsól, V; Fell, A F; Kvasnicková, E; Hais, I M

    1997-02-07

    The major metabolite of a novel non-steroidal anti-inflammatory drug, DL-4-(2',4'-difluorobiphenyl-4-yl)-2-oxo-2-methylbutanoic acid (flobufen, I), namely 4-(2',4'-difluorobiphenyl-4-yl)-2-methyl-gamma-butyrolactone (4-dihydroflobufen lactone, III), has four stereoisomers consisting of two racemic pairs of enantiomers. Of three chiral stationary phases tested, Cyclobond I beta-RSP (Astec) (beta-cylodextrin derivatized with R,S-hydroxypropyl) was best able to separate the (+2)(--) racemate, with a liquid phase containing acetonitrile as modifier and triethylamine acetate as buffer. Using the Box-Wilson Central Composite Design for three factors, an optimum combination of pH and concentrations of the modifier and buffer was eventually obtained. A chromatographic response function based on a combination of the Kaiser peak separation function, Pi, and retention time of the second eluting enantiomer, tRL, served as a response criterion for the process of optimization. The optimum conditions developed for the (+2)(--) racemate were also found to be suitable for separating the (+-)(-+) racemate, for which earlier studies had shown the separation to be more facile. Separation of the four stereoisomers of III, for which the chiral chromatographic system optimized in this study is proposed as the second stage, is targeted at a biochemical study of the stereoisomeric metabolism of I.

  15. On-line separation of Pu(III) and Am(III) using extraction and ion chromatography

    International Nuclear Information System (INIS)

    Jernstroem, J.; Lehto, J.; Betti, M.

    2007-01-01

    An on-line method developed for separating plutonium and americium was developed. The method is based on the use of HPLC pump with three analytical chromatographic columns. Plutonium is reduced throughout the procedure to trivalent oxidation state, and is recovered in the various separation steps together with americium. Light lanthanides and trivalent actinides are separated with TEVA resin in thiocyanate/formic acid media. Trivalent plutonium and americium are pre-concentrated in a TCC-II cation-exchange column, after which the separation is performed in CS5A ion chromatography column by using two different eluents. Pu(III) is eluted with a dipicolinic acid eluent, and Am(III) with oxalic acid eluent. Radiochemical and chemical purity of the eluted plutonium and americium fractions were ensured with alpha-spectrometry. (author)

  16. Gas chromatographic determination of yohimbine in commercial yohimbe products.

    Science.gov (United States)

    Betz, J M; White, K D; der Marderosian, A H

    1995-01-01

    The bark of Pausinystalia yohimbe [K. Schumann] Pierre (Rubiaceae), long valued as an aphrodisiac in West Africa, recently has been promoted in the United States as a dietary supplement alternative to anabolic steroids for enhancement of athletic performance. As the number of yohimbe products on the retail market increases, concerns about their safety are raised because of the reported toxicity of yohimbine (the major alkaloid of the plant). Although plant materials are usually identified microscopically, we were unable to identify them in many of the products, because as their labels indicated, the products were mixtures of various botanicals or were bark extracts and contained little or no plant material. A method for extraction and capillary gas chromatographic (GC) separation of the alkaloids of P. yohimbe was, therefore, developed and used to analyze a number of commercial yohimbe products. The method involved solvent extraction and partitioning in chloroform-water followed by separation on a methyl silicone capillary GC column (N-P detection). Comparisons of chromatograms of extracts of authentic bark with those of commercial products indicated that, although many products contained measurable quantities of the alkaloid yohimbine, they were largely devoid of the other alkaloids previously reported in this species. Concentrations of yohimbine in the commercial products ranged from < 0.1 to 489 ppm, compared with 7089 ppm in the authentic material. Authentic bark has been reported to contain up to 6% total alkaloids, 10-15% of which are yohimbine. The possible presence of undeclared diluents in the products was indicated by peaks in product chromatograms but not in those of authentic bark.

  17. Inorganic gas chromatography - the separation of volatile chlorides by thermochromatography combined with complex formation

    International Nuclear Information System (INIS)

    Tsalas, S.; Baechmann, K.

    1978-01-01

    Separations of the volatile chlorides of I, Te, Sb, Sn, In, Cd, Zr, Hf, Nb, Ta, Mo, Tc, Re, Ru and Os are described. The tube used for the separations has a temperature gradient from 600 0 C to 25 0 C, and is coated with KCl, CsCl, NaCl and BaCl 2 . It is possible to deposit the different compounds at characteristic positions, so that this technique can be used as an on-line chromatographic method. Fission products of uranium-235 were examined. The distribution of the different nuclides was measured with gamma spectrometry. (Auth.)

  18. High-performance ion chromatography method for separation and quantification of inositol phosphates in diets and digesta

    DEFF Research Database (Denmark)

    Blaabjerg, Karoline; Hansen-Møller, Jens; Poulsen, Hanne Damgaard

    2010-01-01

    A gradient high-performance ion chromatographic method for separation and quantification of inositol phosphates (InsP2-InsP6) in feedstuffs, diets, gastric and ileal digesta from pigs was developed and validated. The InsP2-InsP6 were separated on a Dionex CarboPacTM PA1 column using a gradient...... with 1.5 mol L-1 methanesulfonic acid and water. The exchange of the commonly used HCl with methanesulfonic acid has two advantages: (i) the obtained baseline during the separation is almost horizontal and (ii) it is not necessary to use an inert HPIC equipment as the methanesulfonic acid...

  19. GAS CHROMATOGRAPHIC AND SPECTROSCOPIC ANALYSIS OF ...

    African Journals Online (AJOL)

    Peroxyformic acid prepared in-situ was employed for epoxidation of canola oil in the presence of toluene. Gas chromatographic analysis of the product revealed the following species: C16:0; C18:0; C18:1; C18:2; C18:3; monoepoxy C18:0; monoepoxy C18:1; monoepoxy C18:2; diepoxy C18:0; diepoxy C18:1 and triepoxy ...

  20. Partition Efficiency of High-Pitch Locular Multilayer Coil for Countercurrent Chromatographic Separation of Proteins Using Small-Scale Cross-Axis Coil Planet Centrifuge and Application to Purification of Various Collagenases with Aqueous-Aqueous Polymer Phase Systems.

    Science.gov (United States)

    Shinomiya, Kazufusa; Kobayashi, Hiroko; Inokuchi, Norio; Nakagomi, Kazuya; Ito, Yoichiro

    2011-01-01

    Partition efficiency of the high-pitch locular multilayer coil was evaluated in countercurrent chromatographic (CCC) separation of proteins with an aqueous-aqueous polymer phase system using the small-scale cross-axis coil planet centrifuge (X-axis CPC) fabricated in our laboratory. The separation column was specially made by high-pitch (ca 5 cm) winding of 1.0 mm I.D., 2.0 mm O.D. locular tubing compressed at 2 cm intervals with a total capacity of 29.5 mL. The protein separation was performed using a set of stable proteins including cytochrome C, myoglobin, and lysozyme with the 12.5% (w/w) polyethylene glycol (PEG) 1000 and 12.5% (w/w) dibasic potassium phosphate system (pH 9.2) under 1000 rpm of column revolution. This high-pitch locular tubing yielded substantially increased stationary phase retention than the normal locular tubing for both lower and upper mobile phases. In order to demonstrate the capability of the high-pitch locular tubing, the purification of collagenase from the crude commercial sample was carried out using an aqueous-aqueous polymer phase system. Using the 16.0% (w/w) PEG 1000 - 6.3% (w/w) dibasic potassium phosphate - 6.3% (w/w) monobasic potassium phosphate system (pH 6.6), collagenase I, II, V and X derived from Clostridium hystolyticum were separated from other proteins and colored small molecular weight compounds present in the crude commercial sample, while collagenase N-2 and S-1 from Streptomyces parvulus subsp. citrinus were eluted with impurities at the solvent front with the upper phase. The collagenase from C. hystolyticum retained its enzymatic activity in the purified fractions. The overall results demonstrated that the high-pitch locular multilayer coil is effectively used for the CCC purification of bioactive compounds without loss of their enzymatic activities.

  1. Partition Efficiency of High-Pitch Locular Multilayer Coil for Countercurrent Chromatographic Separation of Proteins Using Small-Scale Cross-Axis Coil Planet Centrifuge and Application to Purification of Various Collagenases with Aqueous-Aqueous Polymer Phase Systems

    Science.gov (United States)

    Shinomiya, Kazufusa; Kobayashi, Hiroko; Inokuchi, Norio; Nakagomi, Kazuya; Ito, Yoichiro

    2010-01-01

    Partition efficiency of the high-pitch locular multilayer coil was evaluated in countercurrent chromatographic (CCC) separation of proteins with an aqueous-aqueous polymer phase system using the small-scale cross-axis coil planet centrifuge (X-axis CPC) fabricated in our laboratory. The separation column was specially made by high-pitch (ca 5 cm) winding of 1.0 mm I.D., 2.0 mm O.D. locular tubing compressed at 2 cm intervals with a total capacity of 29.5 mL. The protein separation was performed using a set of stable proteins including cytochrome C, myoglobin, and lysozyme with the 12.5% (w/w) polyethylene glycol (PEG) 1000 and 12.5% (w/w) dibasic potassium phosphate system (pH 9.2) under 1000 rpm of column revolution. This high-pitch locular tubing yielded substantially increased stationary phase retention than the normal locular tubing for both lower and upper mobile phases. In order to demonstrate the capability of the high-pitch locular tubing, the purification of collagenase from the crude commercial sample was carried out using an aqueous-aqueous polymer phase system. Using the 16.0% (w/w) PEG 1000 – 6.3% (w/w) dibasic potassium phosphate – 6.3% (w/w) monobasic potassium phosphate system (pH 6.6), collagenase I, II, V and X derived from Clostridium hystolyticum were separated from other proteins and colored small molecular weight compounds present in the crude commercial sample, while collagenase N-2 and S-1 from Streptomyces parvulus subsp. citrinus were eluted with impurities at the solvent front with the upper phase. The collagenase from C. hystolyticum retained its enzymatic activity in the purified fractions. The overall results demonstrated that the high-pitch locular multilayer coil is effectively used for the CCC purification of bioactive compounds without loss of their enzymatic activities. PMID:21869859

  2. Temperature-responsive chromatography for the separation of biomolecules.

    Science.gov (United States)

    Kanazawa, Hideko; Okano, Teruo

    2011-12-09

    Temperature-responsive chromatography for the separation of biomolecules utilizing poly(N-isopropylacrylamide) (PNIPAAm) and its copolymer-modified stationary phase is performed with an aqueous mobile phase without using organic solvent. The surface properties and function of the stationary phase are controlled by external temperature changes without changing the mobile-phase composition. This analytical system is based on nonspecific adsorption by the reversible transition of a hydrophilic-hydrophobic PNIPAAm-grafted surface. The driving force for retention is hydrophobic interaction between the solute molecules and the hydrophobized polymer chains on the stationary phase surface. The separation of the biomolecules, such as nucleotides and proteins was achieved by a dual temperature- and pH-responsive chromatography system. The electrostatic and hydrophobic interactions could be modulated simultaneously with the temperature in an aqueous mobile phase, thus the separation system would have potential applications in the separation of biomolecules. Additionally, chromatographic matrices prepared by a surface-initiated atom transfer radical polymerization (ATRP) exhibit a strong interaction with analytes, because the polymerization procedure forms a densely packed polymer, called a polymer brush, on the surfaces. The copolymer brush grafted surfaces prepared by ATRP was an effective tool for separating basic biomolecules by modulating the electrostatic and hydrophobic interactions. Applications of thermally responsive columns for the separations of biomolecules are reviewed here. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. High Performance Liquid Chromatographic Method for the Determination of Piroxicam, Naproxen, Diclofenac Sodium, and Mefenamic Acid in Bulk Drug and Pharmaceutical Preparations

    Directory of Open Access Journals (Sweden)

    Sarmad Bahjat Dikran

    2018-03-01

    Full Text Available A simple accurate and rapid reversed phase high performance liquid chromatographic method has been developed and validated for the determination of four nonsteroidal anti-inflammatory drugs;  Piroxicam(PX,  Naproxen(NAP,  Diclofenac sodium(DCL and Mefenamic acid(MFNC in their pure form and different commercial pharmaceutical formulation. The separation was performed on a NUCLEODUR® 100-5 C18ec (250 × 4.6 mm i.d.; particle size 5 μm column as stationary phase with a mobile phase comprising of acetonitrile: deionized water acidified with 1% acetic acid in gradient mode. The flow rate was 1.5 mL.min-1 at the temperature 35 ºC and detection was carried out at 264 nm. Separation has been completed within 8 min. The retention times of Piroxicam, Naproxen, Diclofenac sodium, and Mefenamic acid were 4.267 min, 4.785 min, 6.555 min, and 7.683 min respectively. The linearity for Piroxicam was in the range of 3–200 μg.mL-1 and for Naproxen and Mefenamic acid was in the range 1-200 μg.mL-1, while for Diclofenac sodium was in the range 1.5–200 μg.mL-1. The proposed method was successfully applied for the determination of these drugs in their pure form and different pharmaceutical preparations (tablets, capsules, and ampoule and there is no interference with additives.

  4. Dependence of chlorine isotope separation in ion exchange chromatography on the nature and concentration of the eluent

    International Nuclear Information System (INIS)

    Heumann, K.G.; Baier, K.

    1980-01-01

    In a heterogeneous electrolyte system of a strongly basic anion exchanger and solutions of NaBF 4 or NaClO 4 we established the influence of the nature and concentration of the eluent in chromatographic experiments on chlorine isotope separation. Results show that when the elctrolyte concentration is increased the degree of isotope separation decreases. With NaBF 4 the separation factor is greater than with NaClO 4 under conditions which are otherwise the same. For electrolyte solutions containing ClO 4 -, NO 3 - and BF 4 - there is a linear relation between the separation factor of the chlorine isotopes and the logarithm of the heat of anion hydration of the elution electrolyte. (orig.)

  5. Nano-liquid chromatography applied to enantiomers separation.

    Science.gov (United States)

    Fanali, Salvatore

    2017-02-24

    This paper presents the state of the art concerning the separation of chiral compounds by means of nano-liquid chromatography (nano-LC). The enantiomers' separation and determination are a subject of fundamental importance in various application fields such as pharmaceutical industry, biomedicine, food, agrochemical etc. Nano-LC is a miniaturized chromatographic technique offering some advantages over conventional ones such as low consumption of mobile phase, sample volume and amount of chiral stationary phase, reduced costs etc. This is reported in the first part of the paper illustrating the features of the nano-LC. In addition, chiral resolution methods are briefly illustrated. Some chiral selectors, used in high-performance liquid chromatography have also been applied in nano-LC including cyclodextrins, glycopeptide antibiotics, modified polysaccharides etc. This is discussed in the second part of the review. Finally some examples of the applications available in literature are reported. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Affinity composite cryogel discs functionalized with Reactive Red 120 and Green HE 4BD dye ligands: Application on the separation of human immunoglobulin G subclasses

    Energy Technology Data Exchange (ETDEWEB)

    Huseynli, Sabina; Baydemir, Gözde; Sarı, Esma [Department of Chemistry, Biochemistry Division, Hacettepe University, Ankara (Turkey); Elkak, Assem [Laboraory of “Valorisation des Ressources Naturelles et Produits de Santé (VRNPS)”, Doctoral School of Sciences and Technology, Lebanese University, Rafic Hariri University Campus, Hadath (Lebanon); Denizli, Adil, E-mail: denizli@hacettepe.edu.tr [Department of Chemistry, Biochemistry Division, Hacettepe University, Ankara (Turkey)

    2015-01-01

    Naturally produced by the human immune system, immunoglobulin nowadays is widely used for in vivo and in vitro purposes. The increased needs for pure immunoglobulin have prompted researchers to find new immunoglobulin chromatographic separation processes. Cryogels as chromatographic adsorbents, congregate several mechanical features including good compatibility, large pore structure, flexibility, short diffusion pathway and stability. These different characteristics make them a good alternative to conventional chromatographic methods and allowing their potential use in separation technology. In the present study, two sets of poly(2-hydroxyethyl methacrylate) (PHEMA) based beads were prepared and functionalized with Reactive Red 120 (RR) and Reactive Green HE 4BD (RG) dyes, and then embedded into supermacroporous cryogels. The morphology, physical and chemical features of the prepared bead embedded composite cryogel discs (CCDs) were performed by scanning electron microscopy (SEM), swelling test, elemental analysis and Fourier transform infrared spectroscopy (FTIR). The results showed that the embedded composite cryogel discs have a specific surface area of 192.0 m{sup 2}/g with maximum adsorption capacity of HIgG 239.8 mg/g for the RR functionalized CCD and 170 mg/g for RG functionalized CCD columns, both at pH 6.2. - Highlights: • Dye attached composite cryogel discs were prepared to separate HIgG subclasses. • Composite cryogels characterized by swelling, FTIR, SEM and elemental analysis. • Reactive Green HE 4B and Reactive Red 120 dyes were used as the affinity ligand. • HIgG and subclasses were separate from both aqueous solution and human plasma.

  7. Affinity composite cryogel discs functionalized with Reactive Red 120 and Green HE 4BD dye ligands: Application on the separation of human immunoglobulin G subclasses

    International Nuclear Information System (INIS)

    Huseynli, Sabina; Baydemir, Gözde; Sarı, Esma; Elkak, Assem; Denizli, Adil

    2015-01-01

    Naturally produced by the human immune system, immunoglobulin nowadays is widely used for in vivo and in vitro purposes. The increased needs for pure immunoglobulin have prompted researchers to find new immunoglobulin chromatographic separation processes. Cryogels as chromatographic adsorbents, congregate several mechanical features including good compatibility, large pore structure, flexibility, short diffusion pathway and stability. These different characteristics make them a good alternative to conventional chromatographic methods and allowing their potential use in separation technology. In the present study, two sets of poly(2-hydroxyethyl methacrylate) (PHEMA) based beads were prepared and functionalized with Reactive Red 120 (RR) and Reactive Green HE 4BD (RG) dyes, and then embedded into supermacroporous cryogels. The morphology, physical and chemical features of the prepared bead embedded composite cryogel discs (CCDs) were performed by scanning electron microscopy (SEM), swelling test, elemental analysis and Fourier transform infrared spectroscopy (FTIR). The results showed that the embedded composite cryogel discs have a specific surface area of 192.0 m 2 /g with maximum adsorption capacity of HIgG 239.8 mg/g for the RR functionalized CCD and 170 mg/g for RG functionalized CCD columns, both at pH 6.2. - Highlights: • Dye attached composite cryogel discs were prepared to separate HIgG subclasses. • Composite cryogels characterized by swelling, FTIR, SEM and elemental analysis. • Reactive Green HE 4B and Reactive Red 120 dyes were used as the affinity ligand. • HIgG and subclasses were separate from both aqueous solution and human plasma

  8. Assessing thermochromatography as a separation method for nuclear forensics. Current capability vis-a-vis forensic requirements

    International Nuclear Information System (INIS)

    Hanson, D.E.; Garrison, J.R.; Hall, H.L.

    2011-01-01

    Nuclear forensic science has become increasingly important for global nuclear security. However, many current laboratory analysis techniques are based on methods developed without the imperative for timely analysis that underlies the post-detonation forensics mission requirements. Current analysis of actinides, fission products, and fuel-specific materials requires time-consuming chemical separation coupled with nuclear counting or mass spectrometry. High-temperature gas-phase separations have been used in the past for the rapid separation of newly created elements/isotopes and as a basis for chemical classification of that element. We are assessing the utility of this method for rapid separation in the gas-phase to accelerate the separations of radioisotopes germane to post-detonation nuclear forensic investigations. The existing state of the art for thermo chromatographic separations, and its applicability to nuclear forensics, will be reviewed. (author)

  9. Influence of elution rate on the efficiency of chromatographic separation process of rare earth and transplutonium elements

    International Nuclear Information System (INIS)

    Peshkov, A.S.; Chuveleva, Eh.A.; Nazarov, P.P.; Rybakov, S.Yu.

    1990-01-01

    Applicability of finely dispersed sulfocationites of the KU-2-8 MD grade for the separation of radionuclides of rare earth and transplutonium element separation by the method of replacing complexing chromatography (RCC) has been investigated. Using as an example separation of neodymium-praseodymium, yttrium-europium by the RCC method, using nitriloacetic (1) and diethylenetriaminepentaacetic (2) acid solutions as eluent, the dependence of the element separation of ficiency on elution rate is shown. It is found that when using solution 1 as eluent, the value of the height equivalent to theoretical plate depends on elution rate much less, than in case of solution 2. The conclusion is made that for 1 the main contribution to the blurring of the areas is made by transcolumn effect, and for 2 -by transcolumn and transpartial effects

  10. Paper chromatographic behavior of tetranitronitrosylruthenate and its decomposition products

    International Nuclear Information System (INIS)

    Akatsu, Eiko

    1981-01-01

    The paper chromatographic behavior of tetranitronitrosylruthenate was examined together with its decomposition products. First, Rf values at various eluting conditions were studied with five kinds of papers, since there was a discrepancy among the reported Rf values. Usually Rf of 0.9 was obtained by the recommended procedure of Wain, et al. Second, stability of the tetranitrosylruthenate in water was followed by paper chromatography. No change was found until 200 days passed. Third, the tetranitronitrosylruthenate was warmed in acid, and its decomposition products were studied through the paper chromatography. The paper chromatographic behavior showed that the sample kept in water more than 200 days seemed to contain a dinitro complex, and the sample warmed in acid seemed to be decomposed to a mononitro complex of further. (author)

  11. Experimental designs for modeling retention patterns and separation efficiency in analysis of fatty acid methyl esters by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Skartland, Liv Kjersti; Mjøs, Svein A; Grung, Bjørn

    2011-09-23

    The retention behavior of components analyzed by chromatography varies with instrumental settings. Being able to predict how changes in these settings alter the elution pattern is useful, both with regards to component identification, as well as with regards to optimization of the chromatographic system. In this work, it is shown how experimental designs can be used for this purpose. Different experimental designs for response surface modeling of the separation of fatty acid methyl esters (FAME) as function of chromatographic conditions in GC have been evaluated. Full factorial, central composite, Doehlert and Box-Behnken designs were applied. A mixture of 38 FAMEs was separated on a polar cyanopropyl substituted polysilphenylene-siloxane phase capillary column. The temperature gradient, the start temperature of the gradient, and the carrier gas velocity were varied in the experiments. The modeled responses, as functions of chromatographic conditions, were retention time, retention indices, peak widths, separation efficiency and resolution between selected peak pairs. The designs that allowed inclusion of quadratic terms among the predictors performed significantly better than factorial design. Box-Behnken design provided the best results for prediction of retention, but the differences between the central composite, Doehlert and Box-Behnken designs were small. Retention indices could be modeled with much better accuracy than retention times. However, because the errors of predicted tR of closely eluting peaks were highly correlated, models of resolution (Rs) that were based on retention time had errors in the same range as corresponding models based on ECL. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Unified superresolution experiments and stochastic theory provide mechanistic insight into protein ion-exchange adsorptive separations.

    Science.gov (United States)

    Kisley, Lydia; Chen, Jixin; Mansur, Andrea P; Shuang, Bo; Kourentzi, Katerina; Poongavanam, Mohan-Vivekanandan; Chen, Wen-Hsiang; Dhamane, Sagar; Willson, Richard C; Landes, Christy F

    2014-02-11

    Chromatographic protein separations, immunoassays, and biosensing all typically involve the adsorption of proteins to surfaces decorated with charged, hydrophobic, or affinity ligands. Despite increasingly widespread use throughout the pharmaceutical industry, mechanistic detail about the interactions of proteins with individual chromatographic adsorbent sites is available only via inference from ensemble measurements such as binding isotherms, calorimetry, and chromatography. In this work, we present the direct superresolution mapping and kinetic characterization of functional sites on ion-exchange ligands based on agarose, a support matrix routinely used in protein chromatography. By quantifying the interactions of single proteins with individual charged ligands, we demonstrate that clusters of charges are necessary to create detectable adsorption sites and that even chemically identical ligands create adsorption sites of varying kinetic properties that depend on steric availability at the interface. Additionally, we relate experimental results to the stochastic theory of chromatography. Simulated elution profiles calculated from the molecular-scale data suggest that, if it were possible to engineer uniform optimal interactions into ion-exchange systems, separation efficiencies could be improved by as much as a factor of five by deliberately exploiting clustered interactions that currently dominate the ion-exchange process only accidentally.

  13. Separation and analysis of middle oil by absorption from low-temperature tar

    Energy Technology Data Exchange (ETDEWEB)

    Fushizaki, Y; Ogawa, M; Kubo, Y

    1953-01-01

    Analysis of a neutral fraction (208/sup 0/ to 216.5/sup 0/) from middle oil is carried out by chromatographic adsorption. Silica gel is used as an adsorbent, and a displacement-development procedure is applied. The separation of constituents of the middle-oil fraction is not as easy as of the light fraction. The constituents of this fraction are considered to be aromatic and naphthenic hydrocarbons mostly, and a small quantity of crystalline naphthalene is isolated.

  14. Optimization of chromatographic conditions for determination of aflatoxin B1, B2, G1 and G2 by using liquid chromatography-mass Spectrometry

    Science.gov (United States)

    Ramadhaningtyas, Dillani Putri; Aryana, Nurhani; Aristiawan, Yosi; Styarini, Dyah

    2017-11-01

    The optimization of instrument condition and chromatographic separation for analysis of aflatoxin B1, B2, G1 and G2 using liquid chromatography tandem with mass spectrometer detector was conducted in the aim to provide more accurate and reliable analysis results. The aflatoxin known to be serious threat for human health as it is classified as the carcinogenic compounds. The aflatoxin B1, B2, G1 and G2 were selected due to its extensive contamination in various agricultural commodities. The best chromatographic separation was obtained using C-18 column with gradient elution of solvent 5 mM ammonium acetate and 0.1% formic acid in methanol at 7 minutes runtime analysis. The linearity of the detector showed satisfied results as the coefficient determination found to be 0.9994, 0.9996, 0.9998 and 0.9987 for aflatoxin B1, G1, B2, and G2 respectively in the range concentration from 1 to 20 ng/g. The quantifier ion selected for the aflatoxin B1, B2, G1 and G2 was m/z 285.1, 259, 243 and 313 respectively. The instrument precision at these quantifier ions also showed satisfied result with %RSD was around 3.4 to 6.8%. The optimized method present in this study can be used for further sample analysis.

  15. Separation of carbohydrates using hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Fu, Qing; Liang, Tu; Li, Zhenyu; Xu, Xiaoyong; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2013-09-20

    A strategy was developed to rapidly evaluate chromatographic properties of hydrophilic interaction chromatography (HILIC) columns for separating carbohydrates. Seven HILIC columns (Silica, Diol, TSK Amide-80, XAmide, Click Maltose, Click β-CD, and Click TE-Cys columns) were evaluated by using three monosaccharide and seven disaccharides as probes. The influence of column temperature on the peak shape and tautomerization of carbohydrates, as well as column selectivity were investigated. The influence of surface charge property on the retention was also studied by using glucose, glucuronic acid, and glucosamine, which indicated that buffer salt concentration and pH value in mobile phase was necessary to control the ionic interactions between ionic carbohydrates and HILIC columns. According to evaluation results, the XAmide column was selected as an example to establish experimental schemes for separation of complex mixtures of oligosaccharide. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Correlations between chromatographic parameters and bioactivity predictors of potential herbicides.

    Science.gov (United States)

    Janicka, Małgorzata

    2014-08-01

    Different liquid chromatography techniques, including reversed-phase liquid chromatography on Purosphere RP-18e, IAM.PC.DD2 and Cosmosil Cholester columns and micellar liqud chromatography with a Purosphere RP-8e column and using buffered sodium dodecyl sulfate-acetonitrile as the mobile phase, were applied to study the lipophilic properties of 15 newly synthesized phenoxyacetic and carbamic acid derivatives, which are potential herbicides. Chromatographic lipophilicity descriptors were used to extrapolate log k parameters (log kw and log km) and log k values. Partitioning lipophilicity descriptors, i.e., log P coefficients in an n-octanol-water system, were computed from the molecular structures of the tested compounds. Bioactivity descriptors, including partition coefficients in a water-plant cuticle system and water-human serum albumin and coefficients for human skin partition and permeation were calculated in silico by ACD/ADME software using the linear solvation energy relationship of Abraham. Principal component analysis was applied to describe similarities between various chromatographic and partitioning lipophilicities. Highly significant, predictive linear relationships were found between chromatographic parameters and bioactivity descriptors. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Ceramic membranes for high temperature hydrogen separation

    Energy Technology Data Exchange (ETDEWEB)

    Adcock, K.D.; Fain, D.E.; James, D.L.; Powell, L.E.; Raj, T.; Roettger, G.E.; Sutton, T.G. [East Tennessee Technology Park, Oak Ridge, TN (United States)

    1997-12-01

    The separative performance of the authors` ceramic membranes has been determined in the past using a permeance test system that measured flows of pure gases through a membrane at temperatures up to 275 C. From these data, the separation factor was determined for a particular gas pair from the ratio of the pure gas specific flows. An important project goal this year has been to build a Mixed Gas Separation System (MGSS) for measuring the separation efficiencies of membranes at higher temperatures and using mixed gases. The MGSS test system has been built, and initial operation has been achieved. The MGSS is capable of measuring the separation efficiency of membranes at temperatures up to 600 C and pressures up to 100 psi using a binary gas mixture such as hydrogen/methane. The mixed gas is fed into a tubular membrane at pressures up to 100 psi, and the membrane separates the feed gas mixture into a permeate stream and a raffinate stream. The test membrane is sealed in a stainless steel holder that is mounted in a split tube furnace to permit membrane separations to be evaluated at temperatures up to 600 C. The compositions of the three gas streams are measured by a gas chromatograph equipped with thermal conductivity detectors. The test system also measures the temperatures and pressures of all three gas streams as well as the flow rate of the feed stream. These data taken over a range of flows and pressures permit the separation efficiency to be determined as a function of the operating conditions. A mathematical model of the separation has been developed that permits the data to be reduced and the separation factor for the membrane to be determined.

  18. Modulator Dynamics Shape the Design Space for Stepwise-Elution Simulated Moving Bed Chromatographic Separations.

    Science.gov (United States)

    Wayne, Chris J; Velayudhan, Ajoy

    2018-03-31

    For proteins and other biological macromolecules, SMB chromatography is best operated non-isocratically. However, traditional modes of non-isocratic SMB operation generate significant mobile-phase modulator dynamics. The mechanisms by which these modulator dynamics affect a separation's success, and thus frame the design space, have yet to be explained quantitatively. Here, the dynamics of the modulator (e.g., salts in ion exchange and hydrophobic interaction chromatography) are explicitly accounted for. This leads to the elucidation of two new design constraints, presented as dimensionless numbers, which quantify the effects of the modulator phenomena and thus predict the success of a non-isocratic SMB separation. Consequently, these two new design constraints re-define the SMB design space. Computational and experimental studies at the boundaries of this design space corroborate the theoretical predictions. The design of efficient and robust operating conditions through use of the new design space is also demonstrated. © 2018 The Authors. Biotechnology Journal Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Micro-column plasma emission liquid chromatograph. [Patent application

    Science.gov (United States)

    Gay, D.D.

    1982-08-12

    In a direct current plasma emission spectrometer for use in combination with a microcolumn liquid chromatograph, an improved plasma source unit is claimed. The plasma source unit includes a quartz capillary tube having an inlet means, outlet off gas means and a pair of spaced electrodes defining a plasma region in the tube. The inlet means is connected to and adapted to receive eluant of the liquid chromatograph along with a stream of plasma-forming gas. There is an opening through the wall of the capillary tube penetrating into the plasma region. A soft glass capillary light pipe is disposed at the opening, is connected to the spectrometer, and is adapted to transmit light passing from the plasma region to the spectrometer. There is also a source of electromotive force connected to the electrodes sufficient to initiate and sustain a plasma in the plasma region of the tube.

  20. The separation and determination of fatty acids by isotopic dilution and radiogas-liquid chromatography

    International Nuclear Information System (INIS)

    Beardsley, D.A.

    1981-01-01

    A number of static phases have been evaluated for the GLC separation of fatty acids. Of those investigated, only AT 1200 was capable of resolving the isomeric forms of the acids. A radiogas-liquid chromatographic method incorporating isotopic dilution analysis has been developed for the determination of n-butyric acid. The proposed method has been applied to the determination of the acid in hydrolysed butter fat and milk chocolate extracts. (author)

  1. Carrier effect on separation efficiency of the column in reversed-phase partition chromatography

    International Nuclear Information System (INIS)

    Pszonicka, M.; Siekierski, S.

    1972-01-01

    Chromatographic columns were filled with carriers of diatomaceous earth type (Hyflo Super Cell, and Celite 545) of large pores, and two microporous silica gels respectively. These columns were used for the separation of europium and gadolinium by reversed-phase partition chromatography in the system: stationary phase-diethylhexylphosphoric acid (HDEHP) mobile phase-0.4 N nitric acid. In each case the separation of the above mentioned elements was achieved. The plate height that characterizes separation efficiency of the column, decreases with the decrease of particle diameter of the carrier. Best columns were obtained from carriers of large pores (Hyflo Super Cell and Celite 545) for which plate hights below 0.1 mm could be achieved. Columns filled with microporous silica gels showed plate heights of 0.2-0.3 mm. (author)

  2. Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan

    2015-06-01

    An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Separation of iodine species by adsorption chromatography

    International Nuclear Information System (INIS)

    Machado, E.C.; Bellido Jr, A.V.

    2001-01-01

    Based on the different properties of iodide and iodate species in some sorption materials a new chromatographic method was developed to study the speciation of iodine in a mangrove system. Two sorption materials, alumina and silica, were investigated and several distribution coefficients for iodide and iodate were determined at different concentrations of NaOH, NaNO 3 and NaHCO 3 solutions. The best separation results were obtained percolating sea water samples, containing iodide species, through a glass column filled with alumina. The iodine passed through the column after washing the column with 0.1M sodium nitrate solution, and the iodate was eluted with a 0.5M sodium bicarbonate solution. (author)

  4. High Performance Liquid Chromatographic Analysis of Almotriptan Malate in Bulk and Tablets

    Directory of Open Access Journals (Sweden)

    Chandra Bala Sekaran

    2013-02-01

    Full Text Available Purpose: A simple RP-HPLC method has been developed and validated for the determination of almotriptan malate (ATM in bulk and tablets. Methods: Chromatographic separation of ATM was achieved by using a Thermo Scientific C18 column. A Mobile phase containing a mixture of methanol, water and acetic acid (4:8:0.1 v/v was pumped at the flow rate of 1 mL/min. Detection was performed at 227 nm. According to ICH guidelines, the method was validated. Results: The calibration curve was linear in the concentration range 5–60 μg/mL for the ATM with regression coefficient 0.9999. The method was precise with RSD <1.2%. Excellent recoveries of 99.60 - 100.80% proved the accuracy of the method. The limits of detection and quantification were found to be 0.025 and 0.075 μg/mL, respectively. Conclusion: The method was successfully applied for the quantification of ATM in tablets with acceptable accuracy and precision.

  5. Development, modelling, optimisation and scale-up of chromatographic purification of a therapeutic protein

    DEFF Research Database (Denmark)

    Mollerup, Jørgen; Hansen, Thomas Budde; Kidal, Steffen

    2007-01-01

    Development of a chromatographic purification step proceeds through a number of stages. High-throughput screening techniques are used to identify suitable resins. This technique is also suitable for the design of a capture step and some intermediate chromatographic steps, but development and true...... by industry. The theory of residence time based scale-up is developed and applied. (c) 2007 Elsevier B.V. All rights reserved....

  6. Liquid chromatographic studies on the behaviour of Pu(III), Pu(IV) and Pu(VI) on a RP stationary phase in presence of α-hydroxyisobutyric acid as a chelating agent

    Energy Technology Data Exchange (ETDEWEB)

    Jaison, P.G.; Kumar, Pranaw; Telmore, Vijay M. [Bhabha Atomic Research Centre, Mumbai (India). Fuel Chemistry Division

    2017-06-01

    Since plutonium possesses multiple oxidation states which can coexist in solution, a method for the identification of these oxidation states is important to understand its chemical processes. Liquid chromatographic studies were carried out to compare the chromatographic behaviour of different oxidation states of Pu in presence of the eluent, α-hydroxyisobutyric acid (HIBA). The three oxidation states of Pu viz. Pu(III), Pu(IV) and Pu(VI) were separated under optimised conditions. It was seen that the presence of the complexing agent influences the equilibrium of Pu(III)/(IV) as well as Pu(IV)/(VI) systems. Pu(III) to Pu(IV) conversion was found to be enhanced by high pH and concentration of HIBA whereas a relatively low pH and high concentration of HIBA promotes the conversion of Pu(VI) to Pu(IV).

  7. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  8. Inductively coupled plasma emission spectrometric detection of simulated high performance liquid chromatographic peaks

    International Nuclear Information System (INIS)

    Fraley, D.M.; Yates, D.; Manahan, S.E.

    1979-01-01

    Because of its multielement capability, element-specificity, and low detection limits, inductively coupled plasma optical emission spectrometry (ICP) is a very promising technique for the detection of specific elemental species separated by high performance liquid chromatography (HPLC). This paper evaluated ICP as a detector for HPLC peaks containing specific elements. Detection limits for a number of elements have been evaluated in terms of the minimum detectable concentration of the element at the chromatographic peak maximum. The elements studies were Al, As, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sr, Ti, V, and Zn. In addition, ICP was compared with atomic absorption spectrometry for the detection of HPLC peaks composed of EDTA and NTA chelates of copper. Furthermore, ICP was compared to uv solution absorption for the detection of copper chelates. 6 figures, 4 tables

  9. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  10. Evaluation of differences between dual salt-pH gradient elution and mono gradient elution using a thermodynamic model: Simultaneous separation of six monoclonal antibody charge and size variants on preparative-scale ion exchange chromatographic resin.

    Science.gov (United States)

    Lee, Yi Feng; Jöhnck, Matthias; Frech, Christian

    2018-02-21

    The efficiencies of mono gradient elution and dual salt-pH gradient elution for separation of six mAb charge and size variants on a preparative-scale ion exchange chromatographic resin are compared in this study. Results showed that opposite dual salt-pH gradient elution with increasing pH gradient and simultaneously decreasing salt gradient is best suited for the separation of these mAb charge and size variants on Eshmuno ® CPX. Besides giving high binding capacity, this type of opposite dual salt-pH gradient also provides better resolved mAb variant peaks and lower conductivity in the elution pools compared to single pH or salt gradients. To have a mechanistic understanding of the differences in mAb variants retention behaviors of mono pH gradient, parallel dual salt-pH gradient, and opposite dual salt-pH gradient, a linear gradient elution model was used. After determining the model parameters using the linear gradient elution model, 2D plots were used to show the pH and salt dependencies of the reciprocals of distribution coefficient, equilibrium constant, and effective ionic capacity of the mAb variants in these gradient elution systems. Comparison of the 2D plots indicated that the advantage of opposite dual salt-pH gradient system with increasing pH gradient and simultaneously decreasing salt gradient is the noncontinuous increased acceleration of protein migration. Furthermore, the fitted model parameters can be used for the prediction and optimization of mAb variants separation in dual salt-pH gradient and step elution. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018. © 2018 American Institute of Chemical Engineers.

  11. Titanium dioxide as chemo-affinity chromatographic sorbent of biomolecular compounds - Applications in acidic modification-specific proteomics

    DEFF Research Database (Denmark)

    Engholm-Keller, Kasper; Larsen, Martin R

    2011-01-01

    biomolecules due to its unique ion and ligand exchange properties and high stability towards pH and temperature. Recently, titanium dioxide chromatography was introduced in proteomics as a highly specific method for enriching phosphorylated peptides - a method, which has been widely adapted by the field...... matrices for further characterization is affinity chromatography, which relies on the specific interaction between an analyte in solution and a solid adsorbent. Titanium dioxide-based affinity chromatography has proven to be a versatile tool in enrichment of various compounds such as phosphorylated....... The development of TiO(2)-based chromatographic strategies for separation of various biomolecules from its introduction for small molecules more than 20years ago until recent proteomics applications today will be reviewed here....

  12. Effect of microemulsion component purity on the chromatographic figures of merit in chiral microemulsion electrokinetic chromatography.

    Science.gov (United States)

    Kojtari, Adeline B; Foley, Joe P

    2009-04-17

    Numerous combinations of one-, two-, and three-chiral-component microemulsions have been previously prepared in our group, using N-dodecoxycarbonylvaline (DDCV), 2-hexanol, and ethyl acetate, dibutyl tartrate, or diethyl tartrate. A few results of the various formulations investigated suggested the possible presence of minor impurities in one or more components of the microemulsion. In this study, the purity of the current lots of R- and S-surfactant were measured, as was the subsequent effect of minor impurities on the relevant chromatographic figures of merit (CFOMs) that describe a chiral separation, i.e., efficiency, enantioselectivity, retention, migration window (elution range), and resolution. Two related methods are proposed for correcting enantioselectivities measured in the presence of chiral impurities in the chiral microemulsion.

  13. Chromatographic Analysis of a Multicomponent Mixture of B1, B6, B12, Benfotiamine, and Diclofenac; Part I: HPLC and UPLC Methods for the Simultaneous Quantification of These Five Components in Tablets and Capsules.

    Science.gov (United States)

    Fayed, Ahmed Salah; Hegazy, Maha Abdel-Monem; Wahab, Nada Sayed Abdel

    2016-11-01

    New, simple, highly sensitive, precise, and accurate gradient reversed-phase chromatographic methods were developed using HPLC and ultra-HPLC (UPLC) systems for the determination of five components, namely thiamine, pyridoxine, cyanocobalamin, benfotiamine, and diclofenac in tablets and capsules. The methods were compared for their efficiency in the separation and determination of these five compounds using two different C18 columns (250 × 4.6 mm, 5 μm; and 100 × 4.6 mm, 2.6 μm) for HPLC and UPLC, respectively. Chromatographic separation was performed with a mobile phase containing acetonitrile and 0.025 M phosphate buffer (pH 3.5), with a gradient program and a flow rate of 1.5 and 1.0 mL/min for both methods, respectively. The methods were validated according to International Conference on Harmonization guidelines. Linearity was achieved in the range of 5.00 to 150.00 μg/mL for each of the five compounds. Ruggedness and intermediate precision were confirmed by different analysts on different columns on different days. Moreover, the components were subjected to an accelerated stability study under acidic, alkaline, and oxidative stress conditions and no interfering peaks were observed. The five compounds were efficiently separated in <20 min by HPLC, whereas for UPLC, separation was achieved in <8 min, which dramatically decreased the consumption of organic solvents.

  14. Determination of 90Sr in environmental samples by microwave assisted digestion - chromatographic separation

    International Nuclear Information System (INIS)

    Torres, J.M.; Llaurado, M.; Rauret, G.

    1998-01-01

    The stages involved in the determination of 90 Sr in environmental samples are: sample attack, radiochemical separation (of both 90 Sr and its progeny 90 Y) and measurement. For the determination of 90 Sr, the introduction of microwave-assisted digestion methods has improved acid attack by drastically decreasing both digestion time and the volume of acidic reagents. Recent studies describe many applications of microwave-assisted methods for the determination of inorganic and organometallic compounds in several matrices. We have recently studied the microwave-assisted digestion of soils for the 90 Sr determination. The presented work extends the application of microwaves for the 90 Sr determination to other environmental samples such as sediments, vegetation and milk. An open-focused microwave system, which accepts large samples intakes usually required for radioanalytical chemistry due to the low level content of radionuclides in environmental samples, was used. This system can handle up to 10 g of sample intake which, in many cases, is enough to have acceptable limits of detection. Different digestion procedures are optimised for each matrix studied, paying special attention to the microwave power, the time of digestion and the volume of acidic reagents. Once the sample is in solution a new separation procedure using a specific resin -Sr.Spec- is applied and the measurement is performed by liquid scintillation. The results obtained are compared with a previously optimised method based on liquid-liquid extraction of 90 Y and Cerenkov radiation measurement

  15. MultiSimplex optimization of chromatographic separation and dansyl derivatization conditions in the ultra performance liquid chromatography-tandem mass spectrometry analysis of risperidone, 9-hydroxyrisperidone, monoamine and amino acid neurotransmitters in human urine.

    Science.gov (United States)

    Cai, Hua-Lin; Zhu, Rong-Hua; Li, Huan-De; Zhang, Jun; Li, Lan-Fang

    2011-07-01

    A pre-column dansylated ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-MS/MS) method for simultaneous determination of risperidone (RIP), 9-hydroxyrisperidone (9-OH-RIP), monoamine and amino acid neurotransmitters in human urine was developed with the aim of providing data on how neurotransmitters may influence each other or change simultaneously in response to risperidone treatment. MultiSimplex based on the simplex algorithm and the fuzzy set theory was applied to the optimization of chromatographic separation and dansyl derivatization conditions during method development. This method exhibited excellent linearity for all the analytes with regression coefficients higher than 0.997. The lower limit of quantification (LLOQ) values for 9-OH-RIP and RIP were 0.11 and 0.06 ng/ml, respectively, and for neurotrasmitters ranged from 0.31 to 12.8 nM. The mean accuracy ranged from 94.7% to 108.5%. The mean recovery varied between 81.6% and 97.5%. All the RSD of precision and stability were below 9.7%. Finally, the optimized method was applied to analyze the first morning urine samples of schizophrenic patients treated with risperidone and healthy volunteers. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Chromatographic behavior of carbonate complexes of lanthanides and of thorium in alumina

    International Nuclear Information System (INIS)

    Tomida, E.K.

    1977-01-01

    The chromatographic behavior of some rare earth elements and thorium on alumina is studied in order to evaluate the possibility of separation from concentration of trace rare earths from high-purity thorium compounds. The effect of some factors on complex thorium carbonate formation and the extent of thorium solubility in sodium and potassium carbonate solutions investigated. The sorption of rare earth elements and thoriuum on alumina from alkali carbonate solution is observed, despite the reports that alumina acts as a cation exchanger in alkali media and that thorium and rare earths form stable anionic carbonate complexes. The formation of these elements between alumina and potassium carbonate solutions is studied as a function of pH, carbonate concentration and metal ion concentration. Also the elution of rare earths from alumina is studied and the best results are obtained with mineral acids and EDTA plus alkali carbonate solutions. The effect of some parameters as column aging, mixed solvents, column treatment with organic solvents, temperature, aluant concentration is investigated. Attempting to understand this sorption mechanism, some experiments with strongly basic anion exchanger and cation exchangers of strongly acid and weakly acid type are accomplished. It is observed that there are significant differences, in some conditions, between the behavior of rare earths and of thorium, pointing our the possibility of separation of one lanthanide from others and of these from thorium [pt

  17. Gas chromatographic isolation of individual compounds from complex matrices for radiocarbon dating.

    Science.gov (United States)

    Eglinton, T I; Aluwihare, L I; Bauer, J E; Druffel, E R; McNichol, A P

    1996-03-01

    This paper describes the application of a novel, practical approach for isolation of individual compounds from complex organic matrices for natural abundance radiocarbon measurement. This is achieved through the use of automated preparative capillary gas chromatography (PCGC) to separate and recover sufficient quantities of individual target compounds for (14)C analysis by accelerator mass spectrometry (AMS). We developed and tested this approach using a suite of samples (plant lipids, petroleums) whose ages spanned the (14)C time scale and which contained a variety of compound types (fatty acids, sterols, hydrocarbons). Comparison of individual compound and bulk radiocarbon signatures for the isotopically homogeneous samples studied revealed that Δ(14)C values generally agreed well (±10%). Background contamination was assessed at each stage of the isolation procedure, and incomplete solvent removal prior to combustion was the only significant source of additional carbon. Isotope fractionation was addressed through compound-specific stable carbon isotopic analyses. Fractionation of isotopes during isolation of individual compounds was minimal (radiocarbon measurements. The addition of carbon accompanying derivatization of functionalized compounds (e.g., fatty acids and sterols) prior to chromatographic separation represents a further source of potential error. This contribution can be removed using a simple isotopic mass balance approach. Based on these preliminary results, the PCGC-based approach holds promise for accurately determining (14)C ages on compounds specific to a given source within complex, heterogeneous samples.

  18. Separation of Ra/Ca by ion exchange; Separacion de Ra/Ca por intercambio ionico

    Energy Technology Data Exchange (ETDEWEB)

    Iturbe, J L; Jimenez R, M; Flores M, J

    1991-04-15

    The radium and the calcium belong to the same group in the periodic classification and as consequence both they present very similar chemical properties, that makes difficult its separation. Both elements are also frequently associate in the nature, the calcium is very abundant, the radium is not it and for that reason it is indispensable its separation to analyze to this last one. The alpha spectroscopy is very appropriate to analyze to the {sup 226} Ra, however to achieve a good resolution of the spectra, the samples should contain small quantities of calcium. The purposes of this work were to know the chromatographic behavior of the alkaline-earthy cations: calcium, barium and radium and to apply these knowledge to the separation of the {sup 226} Ra and its analysis by means of alpha spectroscopy. (Author)

  19. Silver ion chromatography for peak resolution enhancement: Application to the preparative separation of two sesquiterpenes using online heart-cutting LC-LC technique.

    Science.gov (United States)

    Yang, Yang; Zhang, Yongmin; Wei, Chong; Li, Jing; Sun, Wenji

    2018-09-01

    Silver ion chromatography, utilizing columns packed with silver ions bonded to silica gel, has proved to be an invaluable technique for the analysis of some positional isomers. In this work, silver ion chromatography by combination with online heart-cutting LC-LC technique for the preparative separation of two sesquiterpenes positional isomers from a natural product was investigated. On the basis of the evaluation that silver ion content impacts on the separation, the laboratory-made silver ion columns, utilizing silica gel impregnated with 15% silver nitrate as column packing materials, were used for peak resolution improvement of these two isomers and the preparative separation of them in heart-cutting LC-LC. The relationship among the maximal sample load, flow rate and peak resolution in the silver ion column were optimized, and the performance of the silver ion column was compared with conventional C 18 column and silica gel column. Based on the developed chromatographic conditions, online heart-cutting LC-LC chromatographic separation system in combination with a silica gel column and a silver ion column that was applied to preparative separation of these two isomers from a traditional Chinese medicine, Inula racemosa Hook.f., was established. The results showed that the online heart-cutting LC-LC technique by combination of a silica gel column and a silver ion column for the preparative separation of these two positional isomers from this natural plant was superior to the preparative separation performed on a single-column system with C 18 column or silica gel column. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Reductive amination of glutaraldehyde 2,4-dinitrophenylhydrazone using 2-picoline borane and high-performance liquid chromatographic analysis.

    Science.gov (United States)

    Uchiyama, Shigehisa; Sakamoto, Hironari; Ohno, Akiko; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2012-09-21

    A typical method for the measurement of glutaraldehyde (GLA) employs 2,4-dinitrophenylhydrazine (DNPH) to form GLA-DNPhydrazone derivatives. However, this method is subject to analytical errors because GLA-DNPhydrazone is a quaternary bis-derivative and forms three geometric isomers (E-E, E-Z and Z-Z) as a result of the two C[double bond, length as m-dash]N double bonds. To overcome this issue, a method for transforming the C[double bond, length as m-dash]N double bond into a C-N single bond, using reductive amination of DNPhydrazone derivatives, has been applied. The amination reaction of GLA-DNPhydrazones with 2-picoline borane is accelerated with catalytic amounts of acid and is completed within 10 minutes in the presence of 100 mmol L(-1) phosphoric acid. Reduction of GLA-DNPhydrazone by 2-picoline borane is unique and results in the formation of N-(2,4-dinitrophenyl)-1-piperidinamine (DNPPA). NMR and LC-APCI-MS data confirmed the product identification. DNPPA is very stable and did not change when stored for at least four weeks at room temperature. DNPPA has excellent solubility of 14.6 g L(-1) at 20 °C in acetonitrile. The absorption maximum wavelength and the molar absorptivity of DNPPA were 351 nm and 4.2 × 10(4) L mol(-1) cm(-1) respectively. Complete separation between the reduced forms of C1-C10 aldehyde DNPhydrazones, including DNPPA, can be achieved by operating the reversed-phase high-performance liquid chromatograph at 351 nm in gradient mode using a C18 amide column. The reductive amination method for GLA overcomes analytical errors caused by E-E, E-Z and Z-Z geometrical isomers.

  1. Isotope dilution inductively coupled plasma quadrupole mass spectrometry in connection with a chromatographic separation for ultra trace determinations of platinum group elements (Pt, Pd, Ru, Ir) in environmental samples.

    Science.gov (United States)

    Müller, M; Heumann, K G

    2000-09-01

    An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.

  2. Separation of hafnium from zirconium in sulfuric acid solutions using pressurized ion exchange

    International Nuclear Information System (INIS)

    Hurst, F.J.

    1981-01-01

    High-resolution pressurized ion exchange has been used successfully to study and separate hafnium and zirconium sulfate complexes by chromatographic elution from Dowex 50W-X8 (15 to 25 μm) resin with sulfuric acid solutions. Techniques were developed to continuously monitor the column effluents for zirconium and hafnium by reaction with fluorometric and colorimetric reagents. Since neither reagent was specific for either metal ion, peak patterns were initially identified by using the stable isotopes 90 Zr and 180 Hf as fingerprints of their elution position. Distribution ratios for both zirconium and hafnium decrease as the inverse fourth power of the sulfuric acid concentration below 2N and as the inverse second power at higher acid concentration. The hafnium-to-zirconium separation factor is approximately constant (approx. 8) over the 0.5 to 3N range. Under certain conditions, an unseparated fraction was observed that was not retained by the resin. The amount of this fraction which is thought to be a polymeric hydrolysis product appears to be a function of metal and sulfuric acid concentrations. Conditions are being sought to give the highest zirconium concentration and the lowest acid concentration that can be used as a feed material for commercial scale-up in the continuous annular chromatographic (CAC) unit without formation of the polymer

  3. Studies on the separation of hydrogen isotopes and spin isomers by gas chromatography

    International Nuclear Information System (INIS)

    Pushpa, K.K.; Annaji Rao, K.

    2000-08-01

    Separation and analysis of mixture of hydrogen isotopes has gained considerable importance because of various applications needing different isotopes in lasers, nuclear reactions and tracer or labelled compounds. In the literature gas chromatographic methods are reported using columns packed with partly dehydrated or thoroughly dehydrated alumina/molecular sieve stationary phase at 77 deg K with helium, neon and even hydrogen or deuterium as carrier gas. In the present study an attempt is made to compare the chromatographic behaviour of these two stationary phases using virgin and Fe doped form in partly dehydrated and thoroughly dehydrated state, using helium, neon, hydrogen and deuterium as carrier gas. The results of this study show that helium or neon carrier gas behave similarly broad peaks with some tailing. Sharp symmetric peaks are obtained with hydrogen or deuterium carrier gas. This is attributed to large hold up capacity for H 2 or D 2 at 77 deg K in these materials as compared to helium or neon. Spin isomers of H 2 or D 2 are separated on Fe free stationary phases, though ortho H 2 and HD are not resolved. Using a combination of Fe doped short column and plain alumina column, both maintained in dehydrated form, the effect of Fe doping on thermal equilibrium of ortho/para forms at 77 deg K is clearly demonstrated. (author)

  4. [Chromatographic mass spectrometric determination of low-molecular-weight aromatic compounds of microbial origin in the serum from patients with sepsis].

    Science.gov (United States)

    Beloborodova, N V; Arkhipova, A S; Beloborodov, D M; Boĭko, N B; Mel'ko, A I; Olenin, A Iu

    2006-02-01

    The investigation quantitatively determined the content of low-molecular-weight aromatic compounds of microbial origin in the sera of 34 individuals by chromatographic mass spectrometry. An "Agilent Technogies 6890N" gas chromatograph with a 5973 mass selective detector was applied; chromatographic separation of components was effected on an Hp-5MS quartz capillary column. Aromatic small molecules originating from microbes (SMOM) were determined in the sera of 7 patients with sepsis. The diagnosis of sepsis was documented by the presence of the systemic inflammation syndrome and by that of bacteriemia and/or artificial ventilation-associated pneumonia along with the level of procalcitonin of higher than 10 ng/ml. The levels of aromatic SMOM were compared in 10 healthy donors, 8 preoperative cardiosurgical patients, and 9 patients with different abnormalities without sepsis treated in an intensive care unit (ICU). Serum phenylacetic and 3-phenylpropionic acids were found to be prevalent in the healthy donors and postoperative cardiosurgical patients. In ICU patients with different complications without sepsis, more than half the compounds under study were undetectable, the others were found in very low concentrations, which may be accounted for by antibiotic therapy. At the same time, almost the whole spectrum of the test compounds (other than 3-phenylpropionic acid) with the highest concentrations of 3-phenyllactic, p-hydroxyphenylacetic, 3-(p-hydroxyphenyl)lactic and 2-hydroxybutanic acids, was detectable in septic patients receiving a more intensive therapy. The differences were statistically significant (by the Mann-Whitney U-test; p < 0.05). By taking into account the potentially high biological activity of the test compounds, studies are to be continued in this area.

  5. High Performance Liquid Chromatographic Method for Determination of Dipyridamole in Human Plasma

    Directory of Open Access Journals (Sweden)

    DAVOOD BEIGI BAND ARAB ADI

    1999-08-01

    Full Text Available A simple, rapid and specific high-performance liquid chromatographic procedure is reported for"nquantitative determination of dipyridamole in human -plasma. The assay uses a reversed-phase"nhigh-performance liquid chromatographic (HPLC and UV detection at 280nm and has a limit"nof detection of approximately 5ng/mL. The mobile phase consists of MeOH-H20 (60:40"nadjusted to pH 3.3. Dipyridamole was extracted from plasma by back-extraction procedure, with"npropranolol as the internal standard. The reproducibility of the method is satisfactory

  6. Separation of furostanol saponins by supercritical fluid chromatography.

    Science.gov (United States)

    Yang, Jie; Zhu, Lingling; Zhao, Yang; Xu, Yongwei; Sun, Qinglong; Liu, Shuchen; Liu, Chao; Ma, Baiping

    2017-10-25

    Supercritical fluid chromatography (SFC) has good separation efficiency and is suitable for separating weakly polar compounds. Furostanol saponins, as an important kind of steroidal saponins, generally have two sugar chains, which are polar and hydrophilic. The hydroxyl group at the C-22 position of furostanol saponins is active and easily reacts with lower alcohols under appropriate conditions. The separation of hydrophilic furostanol saponins was tested by SFC in this study. The effects of chromatographic conditions on the separation of the mixed furostanol saponins and their hydroxyl derivatives at the C-22 position were studied. The conditions for SFC, which included different column polarity, modifier, additive, and column temperature, were tested. After optimization, the mixed 10 similar structures of furostanol saponins were separated in 22min on the Diol column at a temperature of 40°C. The mobile phase was CO 2 (mobile phase A) and methanol (containing 0.2% NH 3 ∙H 2 O and 3% H 2 O) (mobile phase B). The backpressure was maintained isobarically at 11.03MPa. SFC was found to be effective in separating the furostanol saponins that shared the same aglycone but varied in sugar chains. SFC was sensitive to the number and type of sugars. The resolution of furostanol saponin isomers was not ideal. The extract of Dioscorea zingiberensis C. H. Wright was profiled by SFC-quadrupole time-of-flight mass spectrometry. The main saponins of the extract were well separated. Therefore, SFC could be used for separating hydrophilic furostanol saponins and analyzing traditional Chinese medicines that mainly contained steroidal saponins. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. An automatic injection system for rapid radiochemistry

    International Nuclear Information System (INIS)

    Nurmia, M.J.; Kreek, S.A.; Kadkhodayan, B.; Gregorich, K.E.; Lee, D.M.; Hoffman, D.C.

    1992-01-01

    A description is given of the Automated Injection System (AIS), a pneumatically actuated device for automated collection of nuclear reaction products from a He/KCl gas jet transport system. The AIS is used with the Automated Chemical Chromatographic Element Separation System; together these two devices facilitate completely automated separation procedures with improved speed and reproducibility

  8. Separation for the determination of 59/63Ni in radioactive wastes

    International Nuclear Information System (INIS)

    Lee, Chang Heon; Choi, Kwang Soon; Jee, Kwang Young; Kim, Won Ho; Jung, Kie Chul

    2005-01-01

    A study on the separation of 99 Tc, 94 Nb, 55 Fe, 90 Sr and 59/63 Ni in various radioactive wastes discharged from nuclear power plants has been performed for a use in their quantification which is indispensable for the evaluation of the radionuclide inventory. Ni was recovered along with Ca, Mg, Al, Cr, Ti, Mn, Ce, Na, K. and Cu through the sequential separation procedure of Re (as a surrogate of 99 Tc), Nb, Fe and Sr by anion exchange and Sr-SPec extraction chromatography. In this research, chemical separation of Ni from the co-existing elements was investigated by cation exchange and Ni-Spec extraction chromatography. Precipitation behaviour of Ni and the co-existing elements with dimethylglyoxime(DMG) was investigated in ammonium citrate/ethanol-H 2 O and tartaric acid/acetone-H 2 O in order to purify separated Ni fractions and to prepare 59/63 Ni source for the radioactivity measurement using a gas proportional counter. Recovery of Ni separated through ion exchange chromatographic separation procedure was 93.1% with relative standard deviation of 0.9%. In addition, recovery of Ni with DMG in the tartaric acid/acetone-H 2 O was 85.6% with relative standard deviation of 1.9%

  9. Chemometrics and chromatographic fingerprints to classify plant food supplements according to the content of regulated plants.

    Science.gov (United States)

    Deconinck, E; Sokeng Djiogo, C A; Courselle, P

    2017-09-05

    Plant food supplements are gaining popularity, resulting in a broader spectrum of available products and an increased consumption. Next to the problem of adulteration of these products with synthetic drugs the presence of regulated or toxic plants is an important issue, especially when the products are purchased from irregular sources. This paper focusses on this problem by using specific chromatographic fingerprints for five targeted plants and chemometric classification techniques in order to extract the important information from the fingerprints and determine the presence of the targeted plants in plant food supplements in an objective way. Two approaches were followed: (1) a multiclass model, (2) 2-class model for each of the targeted plants separately. For both approaches good classification models were obtained, especially when using SIMCA and PLS-DA. For each model, misclassification rates for the external test set of maximum one sample could be obtained. The models were applied to five real samples resulting in the identification of the correct plants, confirmed by mass spectrometry. Therefore chromatographic fingerprinting combined with chemometric modelling can be considered interesting to make a more objective decision on whether a regulated plant is present in a plant food supplement or not, especially when no mass spectrometry equipment is available. The results suggest also that the use of a battery of 2-class models to screen for several plants is the approach to be preferred. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Separation of traces of traces of trans-plutonium elements in weight quantities of rare earths

    International Nuclear Information System (INIS)

    SORET, Christian

    1969-08-01

    The author reports the separation of trans-plutonium elements and their dosing in a mixture of fission products. In some situations dosing is performed on both rare earths and trans-plutonium elements. The chemical separation process is a chromatographic method of exchange on an anionic resin in concentrated lithium chloride. He proposes a brief overview of separation processes, describes the separation mechanism, and then reports preliminary studies of the influence of increasing quantities of rare earths and the influence of increasing heights of resin bed in order to determine the best conditions of separation. He describes the preparation of resin and of the column, the introduction of the fixing solution at the top of the column, the preparation of lithium chloride solutions. He presents the adjustment and measurement devices, and the calculation of the resin minimum volume. Results are then presented and discussed. The operation mode is addressed: devices, reagents, preparation techniques (preparation of lithium chloride solutions) [fr

  11. Rigorous Multicomponent Reactive Separations Modelling: Complete Consideration of Reaction-Diffusion Phenomena

    International Nuclear Information System (INIS)

    Ahmadi, A.; Meyer, M.; Rouzineau, D.; Prevost, M.; Alix, P.; Laloue, N.

    2010-01-01

    This paper gives the first step of the development of a rigorous multicomponent reactive separation model. Such a model is highly essential to further the optimization of acid gases removal plants (CO 2 capture, gas treating, etc.) in terms of size and energy consumption, since chemical solvents are conventionally used. Firstly, two main modelling approaches are presented: the equilibrium-based and the rate-based approaches. Secondly, an extended rate-based model with rigorous modelling methodology for diffusion-reaction phenomena is proposed. The film theory and the generalized Maxwell-Stefan equations are used in order to characterize multicomponent interactions. The complete chain of chemical reactions is taken into account. The reactions can be kinetically controlled or at chemical equilibrium, and they are considered for both liquid film and liquid bulk. Thirdly, the method of numerical resolution is described. Coupling the generalized Maxwell-Stefan equations with chemical equilibrium equations leads to a highly non-linear Differential-Algebraic Equations system known as DAE index 3. The set of equations is discretized with finite-differences as its integration by Gear method is complex. The resulting algebraic system is resolved by the Newton- Raphson method. Finally, the present model and the associated methods of numerical resolution are validated for the example of esterification of methanol. This archetype non-electrolytic system permits an interesting analysis of reaction impact on mass transfer, especially near the phase interface. The numerical resolution of the model by Newton-Raphson method gives good results in terms of calculation time and convergence. The simulations show that the impact of reactions at chemical equilibrium and that of kinetically controlled reactions with high kinetics on mass transfer is relatively similar. Moreover, the Fick's law is less adapted for multicomponent mixtures where some abnormalities such as counter

  12. [Detection of monoamine neurotransmitters and its metabolites by high performance liquid chromatograph after pre-column derivatization of dansyl chloride column].

    Science.gov (United States)

    Huang, Xiao; Chen, Jia-wen; He, Li-ping; Kang, Xue-jun

    2012-12-01

    To develop a high performance liquid chromatography (HPLC) for detection of monoamine neurotransmitters and its metabolites after pre-column derivatization with dansyl chloride. The C(18) chromatograph column (150 mm×4.6 mm×5 µm) was selected for detection, and derived by dansyl chloride (10 mg/ml) under the condition of 50°C water bath by pH11 buffer solution. 20 µl acetic acid acetone solution (1.0 mol/L) was then mixed in for termination of the reaction. Then the solution was cooling to room temperature, 0.1 mol/L acetic acid zinc-acetonitrile-tetrahydrofuran solution was adopted for mobile phrase, with the volume ratio at 62:35:3. The flow rate was 1.0 ml/min between 0-10 min, 2.0 ml/min between 10-35 min. The ultraviolet detection wavelength was 286 nm. The above method separately detected monoamine neurotransmitters and its metabolites and evaluated the limit of detection, accurate degree and accuracy degree. The linear relations between each component was good in the range of 1 - 20 µg/ml (r = 0.999). The lowest detection limit of norepinephrine, dopamine, 5-hydroxytryptamine and the metabolites 3-methoxy-4-benzoglycols, homovanillic acid and 5-heteroauxin were separately 0.60, 0.80, 0.41, 0.21, 0.19 and 0.1 µg/ml; while the average recovery rates were between 78.5% - 95.9%, and the relative standard deviation (RSD) was 6.62%, 7.64%, 2.98%, 3.60%, 5.09% and 3.09%, respectively. In the process of selection and optimization of the chromatographic conditions, we observed the importance of metal ions to discretion, and discussed the temperature, pH of the buffer solution and dosage of dansyl chloride in derivation. Under the above conditions, the reaction was perfect, and the baseline of the detected materials thoroughly separated. The method to detect monoamine neurotransmitters and its metabolites by HPLC and pre-column derivatization with dansyl chloride was established; and this method could provide reference for the detection of polyamine by HPLC.

  13. Final summarizing report on Grant DE-SC0001014 "Separation of Highly Complex Mixtures by Two-dimension Liquid Chromatography"

    Energy Technology Data Exchange (ETDEWEB)

    Guiochon, Georges [Univ. of Tennessee, Knoxville, TN (United States)

    2013-09-16

    The goal of our research was a fundamental investigation of methods available for the coupling of two separate chromatographic separations that would considerably enhance the individual separation power of each of these two separations. This gain arises from the combination of two independent retention mechanisms, one of them separating the components that coelute on the other column, making possible the separation of many more compounds in a given time. The two separation mechanisms used must be very different. This is possible because many retention mechanisms are available, using different kinds of molecular interactions, hydrophobic or hydrophilic interactions, polar interactions, hydrogen bonding, complex formation, ionic interactions, steric exclusion. Two methods can be used, allowing separations to be performed in space (spreading the bands of sample components on a plate covered with stationary phase layer) or in time (eluting the sample components through a column and detecting the bands leaving the column). Both offer a wide variety of possible combinations and were studied.

  14. Chromatography on cellulose exchangers: microdetermination of Fe/sup 3 +/, UO/sub 2//sup 2 +/, and Cu/sup 2 +/ ions in aqueous solutions by means of small separation columns

    Energy Technology Data Exchange (ETDEWEB)

    Burba, P; Lieser, K H

    1978-01-01

    A study of the use of small separation columns filled with a cellulose exchanger containing salicylic acid as the anchor group for chromatographic determination of Fe/sup 3 +/ and Cu/sup 2 +/ in aqueous solution is described. The detection limits are Fe approx.0.2 and Cu 10 ..mu..g. The separation and simultaneous determination of several ions is possible.

  15. Similarity analyses of chromatographic herbal fingerprints: a review.

    Science.gov (United States)

    Goodarzi, Mohammad; Russell, Paul J; Vander Heyden, Yvan

    2013-12-04

    Herbal medicines are becoming again more popular in the developed countries because being "natural" and people thus often assume that they are inherently safe. Herbs have also been used worldwide for many centuries in the traditional medicines. The concern of their safety and efficacy has grown since increasing western interest. Herbal materials and their extracts are very complex, often including hundreds of compounds. A thorough understanding of their chemical composition is essential for conducting a safety risk assessment. However, herbal material can show considerable variability. The chemical constituents and their amounts in a herb can be different, due to growing conditions, such as climate and soil, the drying process, the harvest season, etc. Among the analytical methods, chromatographic fingerprinting has been recommended as a potential and reliable methodology for the identification and quality control of herbal medicines. Identification is needed to avoid fraud and adulteration. Currently, analyzing chromatographic herbal fingerprint data sets has become one of the most applied tools in quality assessment of herbal materials. Mostly, the entire chromatographic profiles are used to identify or to evaluate the quality of the herbs investigated. Occasionally only a limited number of compounds are considered. One approach to the safety risk assessment is to determine whether the herbal material is substantially equivalent to that which is either readily consumed in the diet, has a history of application or has earlier been commercialized i.e. to what is considered as reference material. In order to help determining substantial equivalence using fingerprint approaches, a quantitative measurement of similarity is required. In this paper, different (dis)similarity approaches, such as (dis)similarity metrics or exploratory analysis approaches applied on herbal medicinal fingerprints, are discussed and illustrated with several case studies. Copyright © 2013

  16. Chromatographic fingerprint similarity analysis for pollutant source identification

    International Nuclear Information System (INIS)

    Xie, Juan-Ping; Ni, Hong-Gang

    2015-01-01

    In the present study, a similarity analysis method was proposed to evaluate the source-sink relationships among environmental media for polybrominated diphenyl ethers (PBDEs), which were taken as the representative contaminants. Chromatographic fingerprint analysis has been widely used in the fields of natural products chemistry and forensic chemistry, but its application to environmental science has been limited. We established a library of various sources of media containing contaminants (e.g., plastics), recognizing that the establishment of a more comprehensive library allows for a better understanding of the sources of contamination. We then compared an environmental complex mixture (e.g., sediment, soil) with the profiles in the library. These comparisons could be used as the first step in source tracking. The cosine similarities between plastic and soil or sediment ranged from 0.53 to 0.68, suggesting that plastic in electronic waste is an important source of PBDEs in the environment, but it is not the only source. A similarity analysis between soil and sediment indicated that they have a source-sink relationship. Generally, the similarity analysis method can encompass more relevant information of complex mixtures in the environment than a profile-based approach that only focuses on target pollutants. There is an inherent advantage to creating a data matrix containing all peaks and their relative levels after matching the peaks based on retention times and peak areas. This data matrix can be used for source identification via a similarity analysis without quantitative or qualitative analysis of all chemicals in a sample. - Highlights: • Chromatographic fingerprint analysis can be used as the first step in source tracking. • Similarity analysis method can encompass more relevant information of pollution. • The fingerprints strongly depend on the chromatographic conditions. • A more effective and robust method for identifying similarities is required

  17. Determination of rare earth elements by liquid chromatographic separation using inductively coupled plasma mass spectrometric detection

    International Nuclear Information System (INIS)

    Braverman, D.S.

    1992-01-01

    High-performance liquid chromatography (HPLC) is used to separate the rare earth elements (REEs) prior to detection by inductively coupled plasma mass spectrometry (ICP-MS). The use of HPLC-ICP-MS in series combines the separation power and speed of HPLC with the sensitivity, isotopic selectivity and speed of ICP-MS. The detection limits for the REEs are in the sub-ng ml -1 range and the response is linear over four orders of magnitude. A preliminary comparison of isotope dilution and external standard results for the determination of REEs in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM 1633a) Fly Ash is presented. (author)

  18. Characterization of plant polysaccharides from Dendrobium officinale by multiple chromatographic and mass spectrometric techniques.

    Science.gov (United States)

    Ma, Huiying; Zhang, Keke; Jiang, Qing; Dai, Diya; Li, Hongli; Bi, Wentao; Chen, David Da Yong

    2018-04-27

    Plant polysaccharides have numerous medicinal functions. Due to the differences in their origins, regions of production, and cultivation conditions, the quality and the functions of polysaccharides can vary significantly. They are macromolecules with large molecular weight (MW) and complex structure, and pose great challenge for the analytical technology used. Taking Dendrobium officinale (DO) from various origins and locations as model samples. In this investigation, mechanochemical extraction method was used to successfully extract polysaccharides from DO using water as solvent, the process is simple, fast (40 s) and with high yield. The MWs of the intact saccharides from calibration curve and light scattering measurement were determined and compared after separation with size exclusion chromatography (SEC). The large polysaccharide was acid hydrolyzed to oligosaccharides and the products were efficiently separated and identified using liquid chromatography coupled to a high resolution tandem mass spectrometry (LC-MS 2 ). Obvious differences were observed among LC-MS 2 chromatograms of digested products, and the chemical structures for the products were proposed based on accurate mass values. More importantly, isomeric digested carbohydrate compounds were explored and characterized. All the chromatographic and mass spectrometric results in this study provided a multi-dimensional characterization, fingerprint analysis, and molecular structure level assessment of plant polysaccharides. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Separation of In (III)and Cd(II) Using Zirconium Vanadate As Inorganic Ion Exchanger

    International Nuclear Information System (INIS)

    Massoud, A.; Abou El Nour, F.

    2012-01-01

    In this work, zirconium vanadate as inorganic ion exchanger was chemically synthesized using homogeneous precipitation technique. The obtained zirconium vanadate was mixed with Indium ions to determine its capacity in aqueous solution using batch experiment. Ion exchange capacity of various metal ions was investigated. Effects of ph, initial concentration, weight of the sorbent and contact time on the adsorption of metals were studied. Chromatographic column methods were applied for separation of indium and cadmium. A fixed bed column of zirconium vanadate was successfully used for separation of indium and cadmium. The recovery percentage of both metal ions was about 98.4% using 2 M HCl and citrate buffer ph 3.5, respectively.

  20. The modified cryogenic adsorption method for the laboratory separation of sup(85)Kr from the atmosphere

    International Nuclear Information System (INIS)

    Wilhelmova, L.; Tomasek, M.; Dvorak, Z.

    1985-01-01

    A method for laboratory separation of sup(85)Kr from the atmosphere based on cryogenic adsorption technique was developed. The physical parameters of the separation equipment were chosen with respect to the properties of scintillation crystal CaFsub(2)(Eu) used as a detector of sup(85)Kr. The apparatus contains dry-ice, silica gel and molecular sieve traps for the removal of Hsub(2)O and COsub(2). The activated charcoal columns are used for concentration and preparation of krypton sample. The separation technique is supplemented by gas-chromatographic determination of total amount of separated krypton. The apparatus enables processing of up to 20 msup(3) of air with the krypton yield about 80%. The relative errors of the determination of the concentration of sup(85)Kr in the air by elaborated method is about 5%. (author)

  1. Gas Chromatographic Mass Spectrometric Determination of Myo-inositol in Humans Utilizing a Deuterated Internal Standard

    DEFF Research Database (Denmark)

    Andersen, Jan Rud; Larsen, Elfinn; Harbo, Helge

    1982-01-01

    The isotopic dilution technique was used for determining the content of myo-inositol in human urine, plasma and haemolysed erythrocyte samples. A deuterated myo-inositol, synthesized from inosose-2 by base-catalysed exchange of hydrogens by deuterium, followed by reduction of the inosose with 2H2......, was added as internal standard to the samples at an early stage in the analytical procedure. After separation and derivatization to the hexa-acetate, the gas chromatographic mass spectrometric analysis was carried out. A 25 m fused silica capillary column coated with methyl silicone was used, and the ions...... selected for monitoring were m/z 210 and m/z 214, which are characteristic and abundant fragment ions from unlabelled and hexadeuterated myo-inositolhexa-acetate, respectively. Calibration curves from water, urine, plasma and haemolysed erythrocytes show parallel, linear responses in the ratio between...

  2. Hydrogen isotope separation experience at the Savannah River Site

    International Nuclear Information System (INIS)

    Lee, M.W.

    1993-01-01

    Savannah River Site (SRS) is a sole producer of tritium for US Weapons Program. SRS has built Facilities, developed the tritium handling processes, and operated safely for the last forty years. Tritium is extracted from the irradiated reactor target, purified, mixed with deuterium, and loaded to the booster gas bottle in the weapon system for limited lifetime. Tritium is recovered from the retired bottle and recycled. Newly produced tritium is branded into the recycled tritium. One of the key process is the hydrogen isotope separation that tritium is separated from deuterium and protium. Several processes have been used for the hydrogen isotope separation at SRS: Thermal Diffusion Column (TD), Batch Cryogenic Still (CS), and Batch Chromatography called Fractional Sorption (FS). TD and CS requires straight vertical columns. The overall system separation factor depends on the length of the column. These are three story building high and difficult to put in glove box. FS is a batch process and slow operation. An improved continuous chromatographic process called Thermal Cycling Absorption Process (TCAP) has been developed. It is small enough to be about to put in a glove box yet high capacity comparable to CS. The SRS tritium purification processes can be directly applicable to the Fusion Fuel Cycle System of the fusion reactor

  3. Separation and determination of strontium-90 in burnout nuclear fuel

    International Nuclear Information System (INIS)

    Khermann, A.; Katsvinkel', I.

    1975-01-01

    Developed was a simple and selective chromatographic method of the separation of strontium-90, by the content of which it is possible to judge about the degree of nuclear fuel burnup. Among the studied ion exchangers for strontium separation the best results are exhibited by strongly acidic organic cationite, i.e. vofatite (on the base of styrene, 8%-divinylbenzene) in the H + form. Elution was performed by hydrochloric or oxalic acids. The method allows to achieve a high degree of Sr-90 purification from other fission products. Using the method the Sr-90 content was determined in burnup fuel of the fuel elements of EK-10 type. At the fuel storage period less than 2 years it becomes necessary to determine both Sr-90 and Sr-89. Determination of Sr-90 in the presence of Sr-89 was made by daughter product of Sr-90 - Y-90, which is separated in ion-exchange coloumn. Some other methods of Sr-90 determination in the presence of Sr-89 are noted

  4. Efficient Separation of Lanthanides Using Poly (Styrene-Divinyl Benzene) Aminated Anion Exchanger

    International Nuclear Information System (INIS)

    Borai, E.H.; Hassan, R.S.; El- Dessouky, M.I.; Ghonem, A.

    2008-01-01

    New chromatographic method was developed for the determination and separation of lanthanides using AS4A anionic column. The behavior of the column towards lanthanides was studied through many parameters, From the data obtained it is found that, affinity of the column toward investigated ions increase by increasing eluent concentration and it decrease retention factors. With the two investigated eluent (oxalic and citric acids), elution order for lanthanide elements was obtained in their atomic number from La to Lu. Retention times and retention orders obtained at these conditions clearly show that, lanthanides in AS4A are displaced according to anion exchange mechanism. More over separation of lanthanides using AS4A was studied using isocratic and gradient elution programs. Light and the first intermediate lanthanide elements were separated successfully by applying a gradient program containing 70% oxalic acid (100 mM) and 30% water. The problem of separation for heavy and the last intermediate lanthanide elements was solved using 100 mM alpha hydroxy isobutyric acid (α-HIBA)

  5. Emotion separation is completed early and it depends on visual field presentation.

    Directory of Open Access Journals (Sweden)

    Lichan Liu

    Full Text Available It is now apparent that the visual system reacts to stimuli very fast, with many brain areas activated within 100 ms. It is, however, unclear how much detail is extracted about stimulus properties in the early stages of visual processing. Here, using magnetoencephalography we show that the visual system separates different facial expressions of emotion well within 100 ms after image onset, and that this separation is processed differently depending on where in the visual field the stimulus is presented. Seven right-handed males participated in a face affect recognition experiment in which they viewed happy, fearful and neutral faces. Blocks of images were shown either at the center or in one of the four quadrants of the visual field. For centrally presented faces, the emotions were separated fast, first in the right superior temporal sulcus (STS; 35-48 ms, followed by the right amygdala (57-64 ms and medial pre-frontal cortex (83-96 ms. For faces presented in the periphery, the emotions were separated first in the ipsilateral amygdala and contralateral STS. We conclude that amygdala and STS likely play a different role in early visual processing, recruiting distinct neural networks for action: the amygdala alerts sub-cortical centers for appropriate autonomic system response for fight or flight decisions, while the STS facilitates more cognitive appraisal of situations and links appropriate cortical sites together. It is then likely that different problems may arise when either network fails to initiate or function properly.

  6. Investigation of special resins for the extraction-chromatogaphic separation of Np and Pu from the process stream of a reprocessing plant for HTR fuel elements

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, G

    1977-03-15

    The effectiveness of several special resins for extraction chromatographic separation of plutonium and neptunium from the process streams of a reprocessing plant was investigated. These special resins consisted of polystyrol and were loaded with Tri-n-octylamine (TOA) during the polymerization process. A commercial structural body of polytrifluormonochlorethylene (Voltalef), subsequently wetted with TOA, served as reference material. Despite its good separation characteristics, this separation body has considerable disadvantages. The individual particles of separation body are only approximately spherical, the homogeneity of the separation bed is consequently only moderate. This size (85% less than 0.062 mm) and the shape of the separation body particles cause high pressure loss in the solution which streams through. Filling the column with the Voltalef separation body is very complicated and often not reproducible. A relatively high elution rate of the stationary phase and low radiation resistance are other disadvantages of this separation body. Because of the unfavorable characteristics of the Voltalef separation body, the above mentioned polystyrol resins have been developed by the Bayer firm. The individual separation body particles of these resins have ideal spherical shape. The diameter of the spheres is 0.4 to 0.6 mm, causing only slight pressure losses in a chromatographic column. A homogeneous and compact column fill is much simpler to achieve with these resins than with Voltalef. Radiation resistance and elution rate of the polystyrol resins correspond to the expectations which must be met during hot operation. The separation characteristics of the investigated polystyrol resins are not optimum, however. The relatively large separation body particles considerably delay the establishment of equilibrium, for two reasons. The rate-determining step during loading is diffusion through an aqueous film, which surrounds the separation body particles.

  7. Impact of solvent conditions on separation and detection of basic drugs by micro liquid chromatography-mass spectrometry under overloading conditions.

    Science.gov (United States)

    Schubert, Birthe; Oberacher, Herbert

    2011-06-03

    In this study the impact of solvent conditions on the performance of μLC/MS for the analysis of basic drugs was investigated. Our aim was to find experimental conditions that enable high-performance chromatographic separation particularly at overloading conditions paired with a minimal loss of mass spectrometric detection sensitivity. A focus was put on the evaluation of the usability of different kinds of acidic modifiers (acetic acid (HOAc), formic acid (FA), methansulfonic acid (CH₃SO₃H), trifluoroacetic acid (TFA), pentafluoropropionic acid (PFPA), and heptafluorobutyric acid (HFBA)). The test mixture consisted of eleven compounds (bunitrolol, caffeine, cocaine, codeine, diazepam, doxepin, haloperidol, 3,4-methylendioxyamphetamine, morphine, nicotine, and zolpidem). Best chromatographic performance was obtained with the perfluorinated acids. Particularly, 0.010-0.050% HFBA (v/v) was found to represent a good compromise in terms of chromatographic performance and mass spectrometric detection sensitivity. Compared to HOAc, on average a 50% reduction of the peak widths was observed. The use of HFBA was particularly advantageous for polar compounds such as nicotine; only with such a hydrophobic ion-pairing reagent chromatographic retention of nicotine was observed. Best mass spectrometric performance was obtained with HOAc and FA. Loss of detection sensitivity induced by HFBA, however, was moderate and ranged from 0 to 40%, which clearly demonstrates that improved chromatographic performance is able to compensate to a large extent the negative effect of reduced ionization efficiency on detection sensitivity. Applications of μLC/MS for the qualitative and quantitative analysis of clinical and forensic toxicological samples are presented. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Stereospecific high-performance liquid chromatographic assay of sotalol in plasma.

    Science.gov (United States)

    Carr, R A; Foster, R T; Bhanji, N H

    1991-09-01

    A convenient high-performance liquid chromatographic (HPLC) assay was developed for determination of sotalol (STL) enantiomers in plasma. Following addition of the internal standard (IS; racemic atenolol), enantiomers of STL and IS were extracted using ethyl acetate. After evaporation of the organic layer, samples were derivatized with a solution of S-(+)-1-(1-naphthyl)ethyl isocyanate (NEIC). The resulting diastereomers were chromatographed with normal-phase HPLC with chloroform:hexane:methanol [65:33:2 (v/v)] as the mobile phase at a flow rate of 2 ml/min. The fluorescence detection wavelength was set at 220 nm for excitation with no emission filter. The suitability of the assay for pharmacokinetic studies was determined by measuring STL enantiomers in the plasma of a healthy subject after administration of a single 160-mg oral, racemic dose of STL.

  9. Separation and purification of γ-aminobutyric acid from fermentation broth by flocculation and chromatographic methodologies.

    Science.gov (United States)

    Gao, Qiang; Duan, Qiang; Wang, Depei; Zhang, Yunze; Zheng, Chunyang

    2013-02-27

    To date, the multifunctional γ-aminobutyric acid (GABA) is mainly produced by microbial fermentation in industry. The purpose of this study was to find an effective method for separation and purification of 31.2 g/L initial GABA from the fermentation broth of Enterococcus raffinosus TCCC11660. To remove the impurities from fermentation broth, flocculation pretreatment using chitosan and sodium alginate was first implemented to facilitate subsequent filtration. Ultrafiltration followed two discontinuous diafiltration steps to effectively remove proteins and macromolecular pigments, and the resulting permeate was further decolored by DA201-CII resin at a high decoloration ratio and GABA recovery. Subsequently, ion exchange chromatography (IEC) with Amberlite 200C resin and gradient elution were applied for GABA separation from glutamate and arginine. Finally, GABA crystals of 99.1% purity were prepared via warm ethanol precipitation twice. Overall, our results reveal that the successive process including flocculation, filtration, ultrafiltration, decoloration, IEC, and crystallization is promising for scale-up GABA extraction from fermentation broth.

  10. Recent advances in SRS on hydrogen isotope separation using thermal cycling absorption process

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, X.; Kit Heung, L.; Sessions, H.T. [Savannah River National Laboratory - SRNL, Aiken, SC (United States)

    2015-03-15

    TCAP (Thermal Cycling Absorption Process) is a gas chromatograph in principle using palladium in the column packing, but it is unique in the fact that the carrier gas, hydrogen, is being isotopically separated and the system is operated in a semi-continuous manner. TCAP units are used to purify tritium. The recent TCAP advances at Savannah River Site (SRS) include compressor-free concept for heating/cooling, push and pull separation using an active inverse column, and compact column design. The new developments allow significantly higher throughput and better reliability from 1/10 of the current production system's footprint while consuming 60% less energy. Various versions are derived in the meantime for external customers to be used in fusion energy projects.

  11. Parameter selection for peak alignment in chromatographic sample profiling: Objective quality indicators and use of control samples

    NARCIS (Netherlands)

    Peters, S.; van Velzen, E.; Janssen, H.-G.

    2009-01-01

    In chromatographic profiling applications, peak alignment is often essential as most chromatographic systems exhibit small peak shifts over time. When using currently available alignment algorithms, there are several parameters that determine the outcome of the alignment process. Selecting the

  12. Liquid chromatographic method for the simultaneous determination of cefalexin and trimethoprim in dog plasma and application to the pharmacokinetic studies of a coformulated preparation.

    Science.gov (United States)

    Qi, Meiling; Wang, Peng; Sun, Ping; Liu, Xia

    2006-03-07

    A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.

  13. Direct separation of plutonium by thermochromatography from environmental samples

    International Nuclear Information System (INIS)

    Wacker, L.; Kraehenbuehl, U.

    2002-01-01

    A thermochromatographic separation was performed on plutonium from environmental soil samples. This procedure was investigated with the goal to measure low concentrations of plutonium by inductively coupled plasma-mass spectrometry (ICP-MS). The soil sample was chlorinated by thionylchloride as reactive gas at a temperature of 1400 K. The volatile chlorides were separated chromatographically and deposited in a temperature gradient tube filled with quartz grains. Results about the deposition behaviour of the elements were obtained. Two different formalisms based on the thermodynamic functions are used to describe the experimental data. One formula is used to describe the deposition behaviour of microscopic amounts of plutonium (adsorption), the other formula for macroamounts of the main matrix elements (desublimation). The calculated values are in a reasonable agreement with the experimental data. A determination of plutonium content was successfully made for a referenced sea sediment (IAEA-135) after the thermochromatographic sample preparation for ICP-MS. (orig.)

  14. Development of an analytical method for separation of phenolic acids by ultra-performance convergence chromatography (UPC2) using a column packed with a sub-2-μm particle.

    Science.gov (United States)

    Jiang, Hai; Yang, Liu; Xing, Xudong; Yan, Meiling; Guo, Xinyue; Yang, Bingyou; Wang, Qiu-Hong; Kuang, Hai-Xue

    2018-05-10

    Phenolic acids are important active components of certain Traditional Chinese Medicines (TCM) and have a wide range of biological effects. Separation and purification of phenolic acids remains challenging due to difficulties with quality control using existing chromatographic methods The purpose of this study was to compare the effects of different chromatographic columns and conditions for the separation of phenolic acids. The BEH column was determined to be optimal, providing efficient separation in the shortest time (17.00 min) using gradient elution with carbon dioxide as the mobile phase, methanol/acetonitrile (70:30, v/v) with 1% TFA as the modifier, and a flow rate of 0.8 mL/min. Good peak shapes were obtained, and the peak asymmetry values were close to 1.00 for all phenolic acids. The resolution was more than 2.83 for all separated peaks. The developed method was subsequently applied to the determination of phenolic acids in Xanthii Fructus. These results are beneficial for quality control and standardization of herbal drugs using UPC 2 , providing an efficient, rapid and environmentally friendly scientific basis for future analysis of phenolic acids. Copyright © 2018. Published by Elsevier B.V.

  15. Design of a coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with polar organic-aqueous two-phase solvent systems.

    Science.gov (United States)

    Shinomiya, Kazufusa; Tokura, Koji; Kimura, Emiru; Takai, Midori; Harikai, Naoki; Yoshida, Kazunori; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2015-05-01

    A new high-speed counter-current chromatograph, named coil satellite centrifuge (CSC), was designed and fabricated in our laboratory. The CSC apparatus produces the satellite motion such that the coiled column simultaneously rotates around the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3). In order to achieve this triplicate rotary motion without twisting of the flow tube, the rotation of each axis was determined by the following formula: ω1=ω2+ω3. This relation enabled to lay out the flow tube without twisting by the simultaneous rotation of three axes. The flow tube was introduced from the bottom side of the apparatus into the sun axis of the first rotary frame reaching the upper side of the planet axis and connected to the column in the satellite axis. The performance of the apparatus was examined on separation of 4-methylumbelliferyl (MU) sugar derivatives as test samples with organic-aqueous two-phase solvent systems composed of ethyl acetate/1-butanol/water (3:2:5, v/v) for lower phase mobile and (1:4:5, v/v) for upper phase mobile. With lower phase mobile, five 4-MU sugar derivatives including β-D-cellobioside (Cel), β-D-glucopyranoside, α-D-mannopyranoside, β-D-fucopyranoside and α-L-fucopyranoside (α-L-Fuc) were separated with the combined rotation around each axis at counterclockwise (CCW) (ω1) - CCW (ω2) - CCW (ω3) by the flow tube distribution. With upper phase mobile, three 4-MU sugar derivatives including α-L-Fuc, β-D-galactopyranoside and Cel were separated with the combined rotation around each axis at clockwise (CW) (ω1) - CW (ω2) - CW (ω3) by the flow tube distribution. A series of experiments on peak resolution and stationary phase retention revealed that better partition efficiencies were obtained at the flow rate of 0.5 mL/min (column 1) and 0.8 mL/min (column 2) for lower phase mobile and 0.2 mL/min (column 1) and 0.4 mL/min (column 2) for upper phase

  16. Validated high-performance thin-layer chromatographic (HPTLC method for simultaneous determination of nadifloxacin, mometasone furoate, and miconazole nitrate cream using fractional factorial design

    Directory of Open Access Journals (Sweden)

    Kalpana G. Patel

    2016-07-01

    Full Text Available A high-performance thin-layer chromatographic method for simultaneous determination of nadifloxacin, mometasone furoate, and miconazole nitrate was developed and validated as per International Conference on Harmonization guidelines. High-performance thin-layer chromatographic separation was performed on aluminum plates precoated with silica gel 60F254 and methanol:ethyl acetate:toluene: acetonitrile:3M ammonium formate in water (1:2.5:6.0:0.3:0.2, % v/v as optimized mobile phase at detection wavelength of 224 nm. The retardation factor (Rf values for nadifloxacin, mometasone furoate, and miconazole nitrate were 0.23, 0.70, and 0.59, respectively. Percent recoveries in terms of accuracy for the marketed formulation were found to be 98.35–99.76%, 99.36–99.65%, and 99.16–100.25% for nadifloxacin, mometasone furoate, and miconazole nitrate, respectively. The pooled percent relative standard deviation for repeatability and intermediate precision studies was found to be < 2% for three target analytes. The effect of four independent variables, methanol content in total mobile phase, wavelength, chamber saturation time, and solvent front, was evaluated by fractional factorial design for robustness testing. Amongst all four factors, volume of methanol in mobile phase appeared to have a possibly significant effect on retention factor of miconazole nitrate compared with the other two drugs nadifloxacin and mometasone furoate, and therefore it was important to be carefully controlled. In summary, a novel, simple, accurate, reproducible, and robust high-performance thin-layer chromatographic method was developed, which would be of use in quality control of these cream formulations.

  17. Liquid chromatographic determination of aniline and derivatives in environmental waters at nanogram per litre levels using fluorescamine pre-column derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Djozan, D. [Univ. of Tabriz (Iran, Islamic Republic of). Dept. of Analytical Chemistry; Faraj-Zadeh, M.A. [Univ. of Tabriz (Iran, Islamic Republic of). Dept. of Analytical Chemistry

    1995-11-01

    Fluorescamine (fluram) has been used as a fluorogenic compound for pre-column derivatization of aniline and some derivatives. Anilines were derivatized with fluram in citrate buffer media (pH 5.5) to form pyrrolinones. The highly fluorescence pyrrolinones were isolated and pre-concentrated by solid phase extraction. A reversed phase, Spherisorb RP-8 column and tetrahydrofuran: Water:formic acid (42:56:2) mobile phase was used for separation. Detection method was by a sensitive fluorimetric method and quantitation was at 395 and 495 nm. The various parameters such as reaction conditions between anilines and fluram, solid phase extraction and chromatographic separation were optimized. Calibrations were linear over the range considered with excellent correlation coefficients (r>0.999). Relative standard deviations are less than 2.5% and detection limits for aniline, p-toluidine, 4-chloroaniline and 4-bromoaniline were 6, 30, 6 and 8 ng L{sup -1}, respectively. This method has been used successfully for the determination of anilines in environmental waters. (orig.)

  18. SIMAC - A phosphoproteomic strategy for the rapid separation of mono-phosphorylated from multiply phosphorylated peptides

    DEFF Research Database (Denmark)

    Thingholm, Tine E; Jensen, Ole N; Robinson, Phillip J

    2008-01-01

    spectrometric analysis, such as immobilized metal affinity chromatography or titanium dioxide the coverage of the phosphoproteome of a given sample is limited. Here we report a simple and rapid strategy - SIMAC - for sequential separation of mono-phosphorylated peptides and multiply phosphorylated peptides from...... and an optimized titanium dioxide chromatographic method. More than double the total number of identified phosphorylation sites was obtained with SIMAC, primarily from a three-fold increase in recovery of multiply phosphorylated peptides....

  19. Bioanalytical method transfer considerations of chromatographic-based assays.

    Science.gov (United States)

    Williard, Clark V

    2016-07-01

    Bioanalysis is an important part of the modern drug development process. The business practice of outsourcing and transferring bioanalytical methods from laboratory to laboratory has increasingly become a crucial strategy for successful and efficient delivery of therapies to the market. This chapter discusses important considerations when transferring various types of chromatographic-based assays in today's pharmaceutical research and development environment.

  20. A Novel Two-Step Liquid-Liquid Extraction Procedure Combined with Stationary Phase Immobilized Human Serum Albumin for the Chiral Separation of Cetirizine Enantiomers along with M and P Parabens

    Directory of Open Access Journals (Sweden)

    Aleksandra Chmielewska

    2016-12-01

    Full Text Available The research into the separation of drug enantiomers is closely related to the safety and efficiency of the drugs. The aim of this study was to develop a simple and validated HPLC method to analyze cetirizine enantiomers. In the case of liquid dosage forms, besides the active substance in large amounts there are usually also inactive ingredients such as methyl- and propylparaben. Unfortunately, these compounds can interfere with the analyte, inter alia during chiral separation of the analyte enantiomers. The proposed innovative two-step liquid-liquid extraction procedure allowed for the determination of cetirizine enantiomers (along with M and P parabens also in liquid dosage forms. The main focus of this study was the chromatographic activity of cetirizine dihydrochloride on the proteinate-based chiral stationary phase. The chromatographic separation of cetirizine enantiomers was performed on an immobilized human serum albumin (HSA column for the first time. Measurements were performed at a wavelength of 227 nm. Under optimal conditions, baseline separation of two enantiomers was obtained with 1.43 enantioseparation factor (α and 1.82 resolution (Rs. Finally, the proposed method was successfully applied to the selected pharmaceutical formulations.

  1. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  2. Incident at university research facility - melt down of gas chromatograph evaporation block and failure of a passive safety barrier

    DEFF Research Database (Denmark)

    Jensen, Niels; Jørgensen, Sten Bay

    2014-01-01

    Two incidents are described highlighting the importance of process hazard analysis in university laboratories. In the first incident, an online gas chromatograph (GC) was being developed. A complete meltdown of the heating blog was experienced during testing because the PC had failed to turn off...... the heating of the evaporation circuit. There had been no design review of the GC, nor any code review of the software controlling the GC. Neither had there been any management of change review for the introduction of the GC in the pilot plant environment, and so the GC had been introduced without any...

  3. Actions of a separately strict cpo-monoid on pointed directed complete posets

    Directory of Open Access Journals (Sweden)

    Halimeh Moghbeli Damaneh

    2015-07-01

    Full Text Available ‎ In the present article‎, ‎we study some categorical properties of the category {$bf‎ Cpo_{Sep}$-$S$} of all {separately strict $S$-cpo's}; cpo's equipped with‎ a compatible right action of a separately strict cpo-monoid $S$ which is‎ strict continuous in each component‎. ‎In particular‎, we show that this category is reflective and coreflective in the‎ category of $S$-cpo's‎, ‎find the free and cofree functors‎, characterize products and coproducts‎. ‎Furthermore‎, ‎epimorphisms and‎  monomorphisms in {$bf Cpo_{Sep}$-$S$} are studied‎, ‎and show that‎ {$bf Cpo_{Sep}$-$S$} is not cartesian closed‎.

  4. Ion-pair high performance liquid chromatographic retention behavior of salicylic acid and its derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.W.; Chung, Y.S. [Chungbuk National University, Cheongju (Korea); Oh, S.K. [Handok Pharmaceuticals Co. Ltd., Chungbuk (Korea)

    1999-06-01

    The ion-pair high performance liquid chromatographic elution behavior of salicylic acid and its derivatives was studied with measuring capacity factor, k', changing the concentration of ion-pairing reagent (tetrabutylammonium chloride, TBACl) in mobile phase. As a result, it was found that k' of the samples increase at pH 7.2 as the TBACl concentration increase. The derivatives of salicylic acid were separated each other at an optimum mobile phase condition which was found from the observation of the retention behavior. The optimum mobile phase condition was methanol solution(MeOH:H{sub 2}O 30:70) containing 20 mM TBACl for the determination of salicylic acid and methanol solution (MeOH:H{sub 2}O 20:80) containing 40 mM TBACl for p-aminosalicylic acid at pH 7.2. The method has been applied for the analysis of the contents of salicylic acid derivatives in an aspirin tablet and a tuberculosis curing agent. 8 refs., 4 figs., 2 tabs.

  5. Generation of accurate peptide retention data for targeted and data independent quantitative LC-MS analysis: Chromatographic lessons in proteomics.

    Science.gov (United States)

    Krokhin, Oleg V; Spicer, Vic

    2016-12-01

    The emergence of data-independent quantitative LC-MS/MS analysis protocols further highlights the importance of high-quality reproducible chromatographic procedures. Knowing, controlling and being able to predict the effect of multiple factors that alter peptide RP-HPLC separation selectivity is critical for successful data collection for the construction of ion libraries. Proteomic researchers have often regarded RP-HPLC as a "black box", while vast amount of research on peptide separation is readily available. In addition to obvious parameters, such as the type of ion-pairing modifier, stationary phase and column temperature, we describe the "mysterious" effects of gradient slope, column size and flow rate on peptide separation selectivity. Retention time variations due to these parameters are governed by the linear solvent strength (LSS) theory on a peptide level by the value of its slope S in the basic LSS equation-a parameter that can be accurately predicted. Thus, the application of shallower gradients, higher flow rates, or smaller columns will each increases the relative retention of peptides with higher S-values (long species with multiple positively charged groups). Simultaneous changes to these parameters that each drive shifts in separation selectivity in the same direction should be avoided. The unification of terminology represents another pressing issue in this field of applied proteomics that should be addressed to facilitate further progress. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Industrial-scale separation of high-purity single-chirality single-wall carbon nanotubes for biological imaging

    Science.gov (United States)

    Yomogida, Yohei; Tanaka, Takeshi; Zhang, Minfang; Yudasaka, Masako; Wei, Xiaojun; Kataura, Hiromichi

    2016-01-01

    Single-chirality, single-wall carbon nanotubes are desired due to their inherent physical properties and performance characteristics. Here, we demonstrate a chromatographic separation method based on a newly discovered chirality-selective affinity between carbon nanotubes and a gel containing a mixture of the surfactants. In this system, two different selectivities are found: chiral-angle selectivity and diameter selectivity. Since the chirality of nanotubes is determined by the chiral angle and diameter, combining these independent selectivities leads to high-resolution single-chirality separation with milligram-scale throughput and high purity. Furthermore, we present efficient vascular imaging of mice using separated single-chirality (9,4) nanotubes. Due to efficient absorption and emission, blood vessels can be recognized even with the use of ∼100-fold lower injected dose than the reported value for pristine nanotubes. Thus, 1 day of separation provides material for up to 15,000 imaging experiments, which is acceptable for industrial use. PMID:27350127

  7. Characterisation of wax works of art by gas chromatographic procedures.

    Science.gov (United States)

    Regert, M; Langlois, J; Colinart, S

    2005-10-14

    To identify the various natural and synthetic substances used by sculptors at the end of the 19th century, several contemporary reference samples were investigated by high temperature gas chromatography (HT GC) and HT GC-MS. Using specific chromatographic conditions and minimising sample preparation, we could separate, detect and identify a wide range of biomolecular markers covering a great variety of molecular weights and volatilities, with a minimum amount of sample, in a single run. Beeswax, spermaceti, carnauba, candellila and Japan waxes as well as pine resin derivatives, animal fats, paraffin, ozokerite and stearin, used as additives in wax works of art, were chemically investigated. In the case of low volatile compounds, transbutylation was performed. The structure of long-chain esters of spermaceti was elucidated for the first time by HT GC-MS analysis. Such a method was then carried out on 10 samples collected on a statuette of Junon by Antoine-Louis Barye (Louvre Museum, Paris, France) and on a sculpture by Aimé-Jules Dalou (Musée de la Révolution Française, Vizille, France). The analytical results obtained provide new data on the complex recipes elaborated by sculptors at the end of the 19th century.

  8. Liquid chromatographic determination of sennosides in Cassia angustifolia leaves.

    Science.gov (United States)

    Srivastava, Alpuna; Pandey, Richa; Verma, Ram K; Gupta, Madan M

    2006-01-01

    A simple liquid chromatographic method was developed for the determination of sennosides B and A in leaves of Cassia angustifolia. These compounds were extracted from leaves with a mixture of methanol-water (70 + 30, v/v) after defatting with hexane. Analyte separation and quantitation were achieved by gradient reversed-phase liquid chromatography and UV absorbance at 270 nm using a photodiode array detector. The method involves the use of an RP-18 Lichrocart reversed-phase column (5 microm, 125 x 4.0 mm id) and a binary gradient mobile-phase profile. The various other aspects of analysis, namely, peak purity, similarity, recovery, repeatability, and robustness, were validated. Average recoveries of 98.5 and 98.6%, with a coefficient of variation of 0.8 and 0.3%, were obtained by spiking sample solution with 3 different concentration solutions of standards (60, 100, and 200 microg/mL). Detection limits were 10 microg/mL for sennoside B and 35 microg/mL for sennoside A, present in the sample solution. The quantitation limits were 28 and 100 microg/mL. The analytical method was applied to a large number of senna leaf samples. The new method provides a reliable tool for rapid screening of C. angustifolia samples in large numbers, which is needed in breeding/genetic engineering and genetic mapping experiments.

  9. General and selective isolation procedure for high-performance liquid chromatographic determination of anabolic steroids in tissues.

    Science.gov (United States)

    Laganà, A; Marino, A

    1991-12-27

    A multi-residue method has been developed for the determination of anabolic steroids in animal tissue. The analytes are extracted from tissue with methanol and the extract is subjected to two solid-phase extractions, one using a non-specific adsorbing material, such as graphitized carbon black (Carbopack B), and the other Amberlite CG-400 I in the OH form. This procedure allowed the neutral anabolics (testosterone, trenbolone and progesterone) to be isolated and separated from the acidic type (phenolic group), such as diethylstilbestrol, oestradiol, zeranol/zearalenone and their respective metabolites. The determination was effected using high-performance liquid chromatography with different detectors (ultraviolet, fluorimetric and electrochemical). Several analytical parameters were studied: chromatographic conditions, recoveries, evaporation step, solvent flow-rate, cartridges reusability, interference of plastic cartridges. For all the anabolics investigated the recoveries were greater than 83.6%.

  10. Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique.

    Science.gov (United States)

    Xie, Wei-Qi; Yu, Kong-Xian; Gong, Yi-Xian

    2018-04-17

    The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Ion chromatographic determination of fluoride and chloride in UO2 using microbore anion exchange columns

    International Nuclear Information System (INIS)

    Kelkar, Anoop; Meena, D.L.; Das, D.K.; Behere, P.G.; Mohd Afzal

    2015-01-01

    Chemical characterization of nuclear fuels is required to ensure that nuclear fuel meets the technical specifications of the fuel. Trace non- metallic impurities like Cl and F is important as they affect clad corrosion. Their effect is more severe in presence of moisture. Chlorine and Fluorine is routinely analysed by ion selective electrode or conventional ion chromatography after pyrohydrolyzing the sample in moist O 2 atmosphere at 950°. Both the technique generates large quantity of liquid waste. Generally 1 ml/min flow rate required for the separation of F - and Cl - in conventional ion-chromatographic separation of F - and Cl - on 4.6- 4.0 mm id analytical column. The waste produced per sample injection is ∼ 30-40 ml with suppressed conductivity detection in ion chromatography. There is a need to reduce this analytical waste in analyzing the radioactive samples for the determination of F - and Cl - . Waste generation could be effectively reduced by using microbore anion exchange analytical column. Present paper describe the use of Metrosep A Supp 16 - 100/2.0 column with Na 2 CO 3 +NaOH mobile phase for the determination of F - and Cl - in UO 2 samples using suppressed conductivity detection

  12. Single-step preparation of selected biological fluids for the high performance liquid chromatographic analysis of fat-soluble vitamins and antioxidants.

    Science.gov (United States)

    Lazzarino, Giacomo; Longo, Salvatore; Amorini, Angela Maria; Di Pietro, Valentina; D'Urso, Serafina; Lazzarino, Giuseppe; Belli, Antonio; Tavazzi, Barbara

    2017-12-08

    Fat-soluble vitamins and antioxidants are of relevance in health and disease. Current methods to extract these compounds from biological fluids mainly need use of multi-steps and multi organic solvents. They are time-consuming and difficult to apply to treat simultaneously large sample number. We here describe a single-step, one solvent extraction of fat-soluble vitamins and antioxidants from biological fluids, and the chromatographic separation of all-trans-retinoic acid, 25-hydroxycholecalciferol, all-trans-retinol, astaxanthin, lutein, zeaxanthin, trans-β-apo-8'-carotenal, γ-tocopherol, β-cryptoxanthin, α-tocopherol, phylloquinone, lycopene, α-carotene, β-carotene and coenzyme Q 10 . Extraction is obtained by adding one volume of biological fluid to two acetonitrile volumes, vortexing for 60s and incubating for 60min at 37°C under agitation. HPLC separation occurs in 30min using Hypersil C18, 100×4.6mm, 5μm particle size column, gradient from 70% methanol+30% H 2 O to 100% acetonitrile, flow rate of 1.0ml/min and 37°C column temperature. Compounds are revealed using highly sensitive UV-VIS diode array detector. The HPLC method suitability was assessed in terms of sensitivity, reproducibility and recovery. Using the present extraction and chromatographic conditions we obtained values of the fat-soluble vitamins and antioxidants in serum from 50 healthy controls similar to those found in literature. Additionally, the profile of these compounds was also measured in seminal plasma from 20 healthy fertile donors. Results indicate that this simple, rapid and low cost sample processing is suitable to extract fat-soluble vitamins and antioxidants from biological fluids and can be applied in clinical and nutritional studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Separation of the lanthanides on high-efficiency bonded phases and conventional ion-exchange resins

    International Nuclear Information System (INIS)

    Elchuk, S.; Cassidy, R.M.

    1979-01-01

    High-performance liquid chromatographic separations (< 20 min) of the lanthanides are illustrated for both 5- and 10-μm bonded-phase strong-acid ion exchangers. The performance of these bonded phase packings is compared with that obtained with a 13-μm styrene-divinylbenzene resin. The eluted metal ions are detected with a variable-wavelength detector after a post-column complexation reaction. The requirements and characteristics of post-column reaction for sensitive metal ion detection after separation on high-performance columns are discussed and the linearity, reproducibility, and sensitivity of the system used in the work are illustrated. The potential of on-column preconcentration for the ultratrace (pg/mL) determination of metal ions is also discussed and illustrated. 7 figures, 2 tables

  14. A high performance liquid chromatographic assay of Mefloquine in saliva after a single oral dose in healthy adult Africans

    Directory of Open Access Journals (Sweden)

    Gbotosho Grace O

    2012-02-01

    Full Text Available Abstract Background Mefloquine-artesunate is a formulation of artemisinin based combination therapy (ACT recommended by the World Health Organization and historically the first ACT used clinically. The use of ACT demands constant monitoring of therapeutic efficacies and drug levels, in order to ensure that optimum drug exposure is achieved and detect reduced susceptibility to these drugs. Quantification of anti-malarial drugs in biological fluids other than blood would provide a more readily applicable method of therapeutic drug monitoring in developing endemic countries. Efforts in this study were devoted to the development of a simple, field applicable, non-invasive method for assay of mefloquine in saliva. Methods A high performance liquid chromatographic method with UV detection at 220 nm for assaying mefloquine in saliva was developed and validated by comparing mefloquine concentrations in saliva and plasma samples from four healthy volunteers who received single oral dose of mefloquine. Verapamil was used as internal standard. Chromatographic separation was achieved using a Hypersil ODS column. Results Extraction recoveries of mefloquine in plasma or saliva were 76-86% or 83-93% respectively. Limit of quantification of mefloquine was 20 ng/ml. Agreement between salivary and plasma mefloquine concentrations was satisfactory (r = 0.88, p Conclusion Disposition of mefloquine in saliva paralleled that in plasma, making salivary quantification of mefloquine potentially useful in therapeutic drug monitoring.

  15. Gas chromatographic analysis of simmondsins and simmondsin ferulates in jojoba meal.

    Science.gov (United States)

    Van Boven, M; Holser, R; Cokelaere, M; Flo, G; Decuypere, E

    2000-09-01

    A capillary gas chromatographic method was developed for the simultaneous determination of simmondsins and simmondsin ferulates in jojoba meal, in detoxified jojoba meal, in jojoba meal extracts, and in animal food mixtures.

  16. [[Chiral separation of five arylpropionic acid drugs and determination of their enantiomers in pharmaceutical preparations by reversed-phase high performance liquid chromatography with cellulose-tris-(4-methylbenzoate) stationary phase

    Science.gov (United States)

    Luo, An; Wan, Qiang; Fan, Huajun; Chen, Zhi; Wu, Xuehao; Huang, Xiaowen; Zang, Linquan

    2014-09-01

    Chromatographic behaviors for enantiomeric separation of arylpropionic acid drugs were systematically developed by reversed phase-high performance liquid chromatography (RP-HPLC) using cellulose-tris-(4-methylbenzoate) (CTMB) as chiral stationary phase (CSP). The effects of the composition of the mobile phase, additives and temperature on chiral separation of flurbiprofen, pranoprofen, naproxen, ibuprofen and loxoprofen were further investigated. The enantiomers had been successfully separated on CSP of CTMB by the mobile phase of methanol-0.1% (v/v) formic acid except naproxen by acetonitrile-0.1% (v/v) formic acid at 25 °C. The mechanisms of the racemic resolution for the above mentioned five drugs are discussed thermodynamically and structurally. The resolutions between respective enantiomers for arylpropionic acid drugs on CTMB had significant differences due to their chromatographic behaviors. The order of resolutions ranked pranoprofen, loxoprofen, flurbiprofen, ibuprofen and naproxen. The method established has been successfully applied to the determination of the enantiomers of the five drugs in commercial preparations under the optimized conditions. It proved that the method is simple, reliable and accurate.

  17. Enhanced binding by dextran-grafting to Protein A affinity chromatographic media.

    Science.gov (United States)

    Zhao, Lan; Zhu, Kai; Huang, Yongdong; Li, Qiang; Li, Xiunan; Zhang, Rongyue; Su, Zhiguo; Wang, Qibao; Ma, Guanghui

    2017-04-01

    Dextran-grafted Protein A affinity chromatographic medium was prepared by grafting dextran to agarose-based matrix, followed by epoxy-activation and Protein A coupling site-directed to sulfhydryl groups of cysteine molecules. An enhancement of both the binding performance and the stability was achieved for this dextran-grafted Protein A chromatographic medium. Its dynamic binding capacity was 61 mg immunoglobulin G/mL suction-dried gel, increased by 24% compared with that of the non-grafted medium. The binding capacity of dextran-grafted medium decreased about 7% after 40 cleaning-in-place cycles, much lower than that of the non-grafted medium as decreased about 15%. Confocal laser scanning microscopy results showed that immunoglobulin G was bound to both the outside and the inside of dextran-grafted medium faster than that of non-grafted one. Atomic force microscopy showed that this dextran-grafted Protein A medium had much rougher surface with a vertical coordinate range of ±80 nm, while that of non-grafted one was ±10 nm. Grafted dextran provided a more stereo surface morphology and immunoglobulin G molecules were more easily to be bound. This high-performance dextran-grafted Protein A affinity chromatographic medium has promising applications in large-scale antibody purification. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Similarity analyses of chromatographic herbal fingerprints: A review

    International Nuclear Information System (INIS)

    Goodarzi, Mohammad; Russell, Paul J.; Vander Heyden, Yvan

    2013-01-01

    Graphical abstract: -- Highlights: •Similarity analyses of herbal fingerprints are reviewed. •Different (dis)similarity approaches are discussed. •(Dis)similarity-metrics and exploratory-analysis approaches are illustrated. •Correlation and distance-based measures are overviewed. •Similarity analyses illustrated by several case studies. -- Abstract: Herbal medicines are becoming again more popular in the developed countries because being “natural” and people thus often assume that they are inherently safe. Herbs have also been used worldwide for many centuries in the traditional medicines. The concern of their safety and efficacy has grown since increasing western interest. Herbal materials and their extracts are very complex, often including hundreds of compounds. A thorough understanding of their chemical composition is essential for conducting a safety risk assessment. However, herbal material can show considerable variability. The chemical constituents and their amounts in a herb can be different, due to growing conditions, such as climate and soil, the drying process, the harvest season, etc. Among the analytical methods, chromatographic fingerprinting has been recommended as a potential and reliable methodology for the identification and quality control of herbal medicines. Identification is needed to avoid fraud and adulteration. Currently, analyzing chromatographic herbal fingerprint data sets has become one of the most applied tools in quality assessment of herbal materials. Mostly, the entire chromatographic profiles are used to identify or to evaluate the quality of the herbs investigated. Occasionally only a limited number of compounds are considered. One approach to the safety risk assessment is to determine whether the herbal material is substantially equivalent to that which is either readily consumed in the diet, has a history of application or has earlier been commercialized i.e. to what is considered as reference material. In order

  19. Similarity analyses of chromatographic herbal fingerprints: A review

    Energy Technology Data Exchange (ETDEWEB)

    Goodarzi, Mohammad [Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research, Vrije Universiteit Brussel, Laarbeeklaan 103, B-1090 Brussels (Belgium); Russell, Paul J. [Safety and Environmental Assurance Centre, Unilever, Colworth Science Park, Sharnbrook, Bedfordshire MK44 1LQ (United Kingdom); Vander Heyden, Yvan, E-mail: yvanvdh@vub.ac.be [Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research, Vrije Universiteit Brussel, Laarbeeklaan 103, B-1090 Brussels (Belgium)

    2013-12-04

    Graphical abstract: -- Highlights: •Similarity analyses of herbal fingerprints are reviewed. •Different (dis)similarity approaches are discussed. •(Dis)similarity-metrics and exploratory-analysis approaches are illustrated. •Correlation and distance-based measures are overviewed. •Similarity analyses illustrated by several case studies. -- Abstract: Herbal medicines are becoming again more popular in the developed countries because being “natural” and people thus often assume that they are inherently safe. Herbs have also been used worldwide for many centuries in the traditional medicines. The concern of their safety and efficacy has grown since increasing western interest. Herbal materials and their extracts are very complex, often including hundreds of compounds. A thorough understanding of their chemical composition is essential for conducting a safety risk assessment. However, herbal material can show considerable variability. The chemical constituents and their amounts in a herb can be different, due to growing conditions, such as climate and soil, the drying process, the harvest season, etc. Among the analytical methods, chromatographic fingerprinting has been recommended as a potential and reliable methodology for the identification and quality control of herbal medicines. Identification is needed to avoid fraud and adulteration. Currently, analyzing chromatographic herbal fingerprint data sets has become one of the most applied tools in quality assessment of herbal materials. Mostly, the entire chromatographic profiles are used to identify or to evaluate the quality of the herbs investigated. Occasionally only a limited number of compounds are considered. One approach to the safety risk assessment is to determine whether the herbal material is substantially equivalent to that which is either readily consumed in the diet, has a history of application or has earlier been commercialized i.e. to what is considered as reference material. In order

  20. Chiral separations of cathinone and amphetamine-derivatives: Comparative study between capillary electrochromatography, supercritical fluid chromatography and three liquid chromatographic modes.

    Science.gov (United States)

    Albals, Dima; Heyden, Yvan Vander; Schmid, Martin G; Chankvetadze, Bezhan; Mangelings, Debby

    2016-03-20

    The screening part of an earlier defined chiral separation strategy in capillary electrochromatography (CEC) was used for the separation of ten cathinone- and amphetamine derivatives. They were analyzed using 4 polysaccharide-based chiral stationary phases (CSPs), containing cellulose tris(3,5-dimethylphenylcarbamate) (ODRH), amylose tris(3,5-dimethylphenylcarbamate) (ADH), amylose tris(5-chloro-2-methylphenylcarbamate) (LA2), and cellulose tris(4-chloro-3-methylphenylcarbamate) (LC4) as chiral selectors. After applying the screening to each compound, ADH and LC4 showed the highest success rate. In a second part of the study, a comparison between CEC and other analytical techniques used for chiral separations i.e., supercritical fluid chromatography (SFC), polar organic solvent chromatography (POSC), reversed-phase (RPLC) and normal-phase liquid chromatography (NPLC), was made. For this purpose, earlier defined screening approaches for each technique were applied to separate the 10 test substances. This allowed an overall comparison of the success rates of the screening steps of the 5 techniques for these compounds. The results showed that CEC had a similar enantioselectivity rate as NPLC and RPLC, producing the highest number of separations (9 out of 10 racemates). SFC resolved 7 compounds, while POSC gave only 2 separations. On the other hand, the baseline separation success rates for NPLC and RPLC was better than for CEC. For a second comparison, the same chiral stationary phases as in the CEC screening were also tested with all techniques at their specific screening conditions, which allowed a direct comparison of the performance of CEC versus the same CSPs in the other techniques. This comparison revealed that RPLC was able to separate all tested compounds, and also produced the highest number of baseline separations on the CSP that were used in the CEC screening step. CEC and NPLC showed the same success rate: nine out of ten substances were separated. When

  1. Simple gas chromatographic method for furfural analysis.

    Science.gov (United States)

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-03

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSDfurfurals will contribute to characterise and quantify their presence in the human diet.

  2. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    International Nuclear Information System (INIS)

    Mihucz, Victor G.; Moricz, Agnes M.; Kroepfl, Krisztina; Szikora, Szilvia; Tatar, Eniko; Parra, Lue Meru Marco; Zaray, Gyula

    2006-01-01

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods

  3. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Mihucz, Victor G. [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); Moricz, Agnes M. [L. Eoetvoes University, Department of Chemical Technology and Environmental Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Kroepfl, Krisztina [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Szikora, Szilvia [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Tatar, Eniko [Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Parra, Lue Meru Marco [Universidad Centro-occidental Lisandro Alvarado, Decanato de Agronomia, Departamento de Quimica y Suelos Unidad de Analisis Instrumental, Apartado Postal 4076, Cabudare 3023 (Venezuela); Zaray, Gyula [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary) and Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary) and L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary)]. E-mail: zaray@ludens.elte.hu

    2006-11-15

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods.

  4. Gas-liquid chromatographic determination of resmethrin in corn, cornmeal, flour, and wheat.

    Science.gov (United States)

    Simonaitis, R A; Cail, R S

    1975-09-01

    A gas-liquid chromatographic (GLC) method was developed for the determination of residues of resmethrin ((5-benzyl-3-furyl)methyl cis-trans-(+/-)-2,2-dimethyl-3-(2-methylpropenyl)-cyclopropanecarboxylate) in corn, cornmeal, flour, and wheat. The commodity, fortified with resmethrin, was extracted by tumbling with pentane and transferred to acetonitrile, the fat was partitioned off, and the sample was chromatographed with 3% ethyl acetate in pentane on Florisil containing 0.5% water. The resmethrin residue was determined by GLC with a flame ionization detector. The results were compared with known standards that had undergone the same cleanup procedures. The method was sensitive to concentrations of resmethrin to 0.2 ppm, recoveries averaged 83%, and reproducibility was good.

  5. Coffee contains cholinomimetic compound distinct from caffeine. I: Purification and chromatographic analysis.

    Science.gov (United States)

    Tse, S Y

    1991-07-01

    Both regular and decaffeinated coffees were found to have cholinomimetic actions when tested in urethane-anesthetized rats. These actions were distinct from those of caffeine and reversible by atropine. The bioactive fraction was purified from alcoholic extracts of instant decaffeinated coffee by liquid column chromatography and preparative TLC. The purified compound showed similar pharmacological actions as the starting material. Chromatographic behavior was further characterized by analytical TLC and HPLC. Chromatographic analyses of extracts of green coffee beans and roasted ground coffees showed that the cardioactive compound was only present in roasted coffees. Similar analyses of other commonly consumed beverages, including teas and cocoa, showed that this compound was not present in beverages besides coffee.

  6. Impurity analysis in EC-99mTC radiotracer using chromatographic techniques

    International Nuclear Information System (INIS)

    Almeida, E.V.; Fukumori, N.T.O.; Mengatti, J.; Silva, C.P.G.; Matsuda, M.M.N.

    2008-01-01

    The objective of this study was to develop two chromatographic methods of impurity analysis in radiotracer 99m Tc-EC: the Thin Layer Chromatography (TLC) and the High Performance Liquid Chromatography Reversed Phase (HPLC-RP)

  7. Rapid thin-layer chromatographic photodensitometric method for the determination of metoclopramide and clebopride in the presence of some of their metabolic products.

    Science.gov (United States)

    Huizing, G; Beckett, A H; Segura, J

    1979-04-21

    Metoclopramide and its newly developed analogue clebopride, together with some of their metabolic products are quantitated, following extraction from biological tissues and fluids, and subsequent separation on silica gel thin-layer chromatographic plates. Diazotisation, followed by coupling with N-(1-naphthyl)ethylenediammonium dichloride, carried out on the thin-layer plate, is utilised for visualisation. The intensity of the spots is measured by photodensitometric analysis. The effect of variation of various experimental conditions is studied. The method has proven to be satisfactory for the measurement of 20 ng/ml of these compounds in biological material; the results are well within the accepted limits of deviation.

  8. The Role Seemingly of Amorphous Silica Gel Layers in Chiral Separations by Planar Chromatography

    Directory of Open Access Journals (Sweden)

    Teresa Kowalska

    2007-12-01

    Full Text Available In planar chromatography, silica gel appears as the most frequently used adsorbent. Its preference as planar chromatographic stationary phase is due to its high specific surface area (ca. 700 m2 g-1 and relatively simple active sites (silanol groups, Si-OH. The high specific surface area of silica gel and a high density of coverage of its surface with the silanol active sites contribute jointly to an excellent separation performance of this adsorbent. In our experiments on chiral separation of the enantiomer pairs by planar chromatography, contradictory behavior of the silica gel layers versus the chiral compounds was observed. The migration tracks of chiral compounds in the ascending planar chromatographic mode were not vertical but bent on either side being a function of analyte chirality. This deviation of the analyte’s migration track was noticed, when using the densitometric scanner to quantify the respective chromatograms. In order to confirm the hypothesis as to the microcrystalline nature of silica gel used in liquid chromatography, it was further investigated through circular dichroism (CD and the data thereof confirmed that the ‘chromatographic’ silica gels are not amorphous but microcrystalline, contributing to the (partial horizontal enantioseparation of the antimer pairs. This paper summarizes the results of our investigation on the microcrystalline nature of silica gels used in planar chromatography and their impact on enantioseparation of the selected pairs of antimers.

  9. Air Separation Using Hollow Fiber Membranes

    Science.gov (United States)

    Huang, Stephen E.

    2004-01-01

    The NASA Glenn Research Center in partnership with the Ohio Aerospace Institute provides internship programs for high school and college students in the areas of science, engineering, professional administrative, and other technical areas. During the summer of 2004, I worked with Dr. Clarence T. Chang at NASA Glenn Research Center s combustion branch on air separation using hollow fiber membrane technology. . In light of the accident of Trans World Airline s flight 800, FAA has mandated that a suitable solution be created to prevent the ignition of fuel tanks in aircrafts. In order for any type of fuel to ignite, three important things are needed: fuel vapor, oxygen, and an energy source. Two different ways to make fuel tanks less likely to ignite are reformulating the fuel to obtain a lower vapor pressure for the fuel and or using an On Board Inert Gas Generating System (OBIGGS) to inert the Central Wing Tank. goal is to accomplish the mission, which means that the Air Separation Module (ASM) tends to be bulky and heavy. The primary goal for commercial aviation companies is to transport as much as they can with the least amount of cost and fuel per person, therefore the ASM must be compact and light as possible. The plan is to take bleed air from the aircraft s engines to pass air through a filter first to remove particulates and then pass the air through the ASM containing hollow fiber membranes. In the lab, there will be a heating element provided to simulate the temperature of the bleed air that will be entering the ASM and analysis of the separated air will be analyzed by a Gas Chromatograph/Mass Spectrometer (GC/MS). The GUMS will separate the different compounds in the exit streams of the ASM and provide information on the performance of hollow fiber membranes. Hopefully I can develop ways to improve efficiency of the ASM. different types of jet fuel were analyzed and data was well represented on SAE Paper 982485. Data consisted of the concentrations of over

  10. Completely integrable operator evolution equations. II

    International Nuclear Information System (INIS)

    Chudnovsky, D.V.

    1979-01-01

    The author continues the investigation of operator classical completely integrable systems. The main attention is devoted to the stationary operator non-linear Schroedinger equation. It is shown that this equation can be used for separation of variables for a large class of completely integrable equations. (Auth.)

  11. Separation of the components of the TBP-H2 MBP-HDBP-H3PO4 mixture

    International Nuclear Information System (INIS)

    Pires, M.A.F.; Abrao, A.

    1981-04-01

    Several schemes for the separation of dibutylphosphoric acid (HDBP), monobutylphosphoric acid (H 2 MBP) and orthophosphoric acid (H 3 PO 4 ) as hydrolytic and radiolytic degradation products from tri-n-butylphosphate (TBP) were studied. For the resolution of a HDBP, H 2 MPB and H 3 PO 4 mixture in TBP-diluent, or in TBP-diluent-heavy metal nitrate (U-VI, Th-IV or Zr-IV), techniques such as ion exchange chromatography, ion chromatography and separation onto a chromatographic alumina column were investigated. For the identification, determination and analytical resolution following up for the several systems studied, techniques such as refraction index measurement, electrical conductivity measurement, molecular spectrophotometry and gas chromatography were applied. Special emphasys was given to the separation using alumina column where the HDBP acid was retained and eluted selectively for its separation from TBP-varsol-uranyl nitrate mixtures. This analytical procedure was applied to the samples coming from the Uranium Purification Pilot Plant in operation at the Centro de Engenharia Quimica (IPEN). (Author) [pt

  12. ChromAlign: A two-step algorithmic procedure for time alignment of three-dimensional LC-MS chromatographic surfaces.

    Science.gov (United States)

    Sadygov, Rovshan G; Maroto, Fernando Martin; Hühmer, Andreas F R

    2006-12-15

    We present an algorithmic approach to align three-dimensional chromatographic surfaces of LC-MS data of complex mixture samples. The approach consists of two steps. In the first step, we prealign chromatographic profiles: two-dimensional projections of chromatographic surfaces. This is accomplished by correlation analysis using fast Fourier transforms. In this step, a temporal offset that maximizes the overlap and dot product between two chromatographic profiles is determined. In the second step, the algorithm generates correlation matrix elements between full mass scans of the reference and sample chromatographic surfaces. The temporal offset from the first step indicates a range of the mass scans that are possibly correlated, then the correlation matrix is calculated only for these mass scans. The correlation matrix carries information on highly correlated scans, but it does not itself determine the scan or time alignment. Alignment is determined as a path in the correlation matrix that maximizes the sum of the correlation matrix elements. The computational complexity of the optimal path generation problem is reduced by the use of dynamic programming. The program produces time-aligned surfaces. The use of the temporal offset from the first step in the second step reduces the computation time for generating the correlation matrix and speeds up the process. The algorithm has been implemented in a program, ChromAlign, developed in C++ language for the .NET2 environment in WINDOWS XP. In this work, we demonstrate the applications of ChromAlign to alignment of LC-MS surfaces of several datasets: a mixture of known proteins, samples from digests of surface proteins of T-cells, and samples prepared from digests of cerebrospinal fluid. ChromAlign accurately aligns the LC-MS surfaces we studied. In these examples, we discuss various aspects of the alignment by ChromAlign, such as constant time axis shifts and warping of chromatographic surfaces.

  13. Determination of SO2 in the atmosphere using radioactive iodine kryptonate as impregnation medium of chromatographic paper

    International Nuclear Information System (INIS)

    Pruzinec, J.

    1975-01-01

    Chromatographic paper was impregnated with radioiodine kryptonate using the macrodiffusion technique. The decrease with time of the activity of the kryptonate-impregnated paper exposed to SO 2 -contaminated air was measured. From the decrease in chromatographic paper activity, the concentration of SO 2 was determined in the range 300 to 700 ppm. (A.K.)

  14. Design of a novel coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with organic-aqueous two-phase solvent systems

    Science.gov (United States)

    Shinomiya, Kazufusa; Tokura, Koji; Kimura, Emiru; Takai, Midori; Harikai, Naoki; Yoshida, Kazunori; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2015-01-01

    A new high-speed counter-current chromatograph, named coil satellite centrifuge (CSC), was designed and fabricated in our laboratory. The CSC apparatus produces the satellite motion such that the coiled column simultaneously rotates around the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3). In order to achieve this triplicate rotary motion without twisting of the flow tube, the rotation of each axis was determined by the following formula: ω1 = ω2 + ω3. This relation enabled to lay out the flow tube by two different ways, the SS type and the JS type. In the SS type, the flow tube was introduced from the upper side of the apparatus into the sun axis of the first rotary frame and connected to the planet axis of the second rotary frame like a double letter SS. In the JS type, the flow tube was introduced from the bottom of the apparatus into the sun axis reaching the upper side of the planet axis an inversed letter J, followed by distribution as in the SS type. The performance of the apparatus was examined on separation of 4-methylumbelliferyl (MU) sugar derivatives as test samples with organic-aqueous two-phase solvent systems composed of ethyl acetate/1-butanol/water (3 : 2 : 5, v/v) for lower phase mobile and (1 : 4 : 5, v/v) for upper phase mobile. With lower phase mobile, five 4-MU sugar derivatives including β-D-cellobioside (Cel), β-D-glucopyranoside, α-D-mannopyranoside, β-D-fucopyranoside and α-L-fucopyranoside (α-L-Fuc) were separated with the combined rotation around each axis at counterclockwise (CCW) (ω1) – CCW (ω2) – CCW (ω3) by the JS type flow tube distribution. With upper phase mobile, three 4-MU sugar derivatives including α-L-Fuc, β-D-galactopyranoside and Cel were separated with the combined rotation around each axis at clockwise (CW) (ω1) – CW (ω2) – CW (ω3) by the JS type flow tube distribution. A series of experiments on peak resolution and

  15. Separation of lanthanides through hydroxyapatite

    International Nuclear Information System (INIS)

    Garcia M, F.G.

    2006-01-01

    With the objective of obtaining from an independent way to each one of the lanthanides 151 Pm, 161 Tb, 166 Ho and 177 Lu free of carrier and with high specific activities starting from the indirect irradiation via, it intends in this work to determine the viability of separation of the couples Nd/Pm, Dy/Ho, Gd/Tb and Yb/Lu, by means of ion exchange column chromatography, using hydroxyapatite (HAp) and fluorite like absorbent material in complexing media. It is important to mention that have registered separation studies among lanthanides of the heavy group with those of the slight group, using the same mass and, in comparison with this work, quantities different from the father were used and of the son, also, that the separation studies were carried out among neighboring lanthanides. In this investigation, it was determined the effect that its have the complexing media: KSCN, sodium tartrate, sodium citrate, EDTA and aluminon, their pH and concentration, in the adsorption of the lanthanides in both minerals, in order to determine the chromatographic conditions for separation of the couples Nd/Pm, Dy/Ho, Gd/Tb and Yb/Lu. The work consists of five chapters, in the first one they are presented a theoretical introduction of the characteristics more important of the lanthanides, the hydroxyapatite and the fluorite; in the second, it is deepened in the ion exchange, as well as the two techniques (XRD and High Vacuum Electron Microscopy) to make the characterization of LnCI 3 (Ln = Nd, Gd, Dy or Yb) synthesized. The third chapter, it describes the methodology continued in our experimental work; in the room, its are presented the obtained results of the static and dynamic method to determine the viability of separation of neighboring lanthanides; and finally, the five chapter shows the conclusions. In this study, it is concludes that the separation among neighboring lanthanides cannot be carried out in the minerals and used media; because practically these lanthanides

  16. Application of Homochiral Alkylated Organic Cages as Chiral Stationary Phases for Molecular Separations by Capillary Gas Chromatography.

    Science.gov (United States)

    Xie, Shengming; Zhang, Junhui; Fu, Nan; Wang, Bangjin; Hu, Cong; Yuan, Liming

    2016-11-08

    Molecular organic cage compounds have attracted considerable attention due to their potential applications in gas storage, catalysis, chemical sensing, molecular separations, etc. In this study, a homochiral pentyl cage compound was synthesized from a condensation reaction of ( S , S )-1,2-pentyl-1,2-diaminoethane and 1,3,5-triformylbenzene. The imine-linked pentyl cage diluted with a polysiloxane (OV-1701) was explored as a novel stationary phase for high-resolution gas chromatographic separation of organic compounds. Some positional isomers were baseline separated on the pentyl cage-coated capillary column. In particular, various types of enantiomers including chiral alcohols, esters, ethers and epoxides can be resolved without derivatization on the pentyl cage-coated capillary column. The reproducibility of the pentyl cage-coated capillary column for separation was investigated using nitrochlorobenzene and styrene oxide as analytes. The results indicate that the column has good stability and separation reproducibility after being repeatedly used. This work demonstrates that molecular organic cage compounds could become a novel class of chiral separation media in the near future.

  17. Application of Homochiral Alkylated Organic Cages as Chiral Stationary Phases for Molecular Separations by Capillary Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Shengming Xie

    2016-11-01

    Full Text Available Molecular organic cage compounds have attracted considerable attention due to their potential applications in gas storage, catalysis, chemical sensing, molecular separations, etc. In this study, a homochiral pentyl cage compound was synthesized from a condensation reaction of (S,S-1,2-pentyl-1,2-diaminoethane and 1,3,5-triformylbenzene. The imine-linked pentyl cage diluted with a polysiloxane (OV-1701 was explored as a novel stationary phase for high-resolution gas chromatographic separation of organic compounds. Some positional isomers were baseline separated on the pentyl cage-coated capillary column. In particular, various types of enantiomers including chiral alcohols, esters, ethers and epoxides can be resolved without derivatization on the pentyl cage-coated capillary column. The reproducibility of the pentyl cage-coated capillary column for separation was investigated using nitrochlorobenzene and styrene oxide as analytes. The results indicate that the column has good stability and separation reproducibility after being repeatedly used. This work demonstrates that molecular organic cage compounds could become a novel class of chiral separation media in the near future.

  18. Liquid chromatographic separation and indirect detection of non-absorbing aliphatic compounds using m-nitrophenol as a detection agent

    International Nuclear Information System (INIS)

    Lee, Seung Seok; Kang, Sam Woo; Moon, Young Ja

    1991-01-01

    m-Nitrophenol(m-NP) was a detection agent for the use of the detection and separation of non-absorbing compounds such as aliphatic acids, alcohols, amines and tetraalkylammonium salts by indirect photometric detection in reversed-phase liquid chromatography. Response of samples was investigated to the several factors such as pH, temperature, and concentration of MeOH as well as concentration of detection reagent in mobile phase. The separation of several mixtures were attempted under optimum condition. (Author)

  19. Quantitative analysis of oxytetracycline and its impurities by LC-MS-MS

    DEFF Research Database (Denmark)

    Lykkeberg, Anne Kruse; Halling-Sørensen, Bent; Cornett, Claus

    2004-01-01

    A liquid chromatographic-tandem mass spectrometric method using an Xterra MS C(18) chromatographic column ( 100 mm x 2.1 mm i.d., 3.5microm) that allows complete separation of oxytetracycline (OTC) and the impurities: 4-epi-oxytetracycline (EOTC), tetracycline (TC), 4-epi-tetracycline (ETC), 2......-acetyl-2-decarboxamido-oxytetracycline (ADOTC), alpha-apo-oxytetracycline (alpha-AOTC) and beta-apo-oxytetracycline (beta-AOTC) was developed. Gradient elution was used and calibration curves were obtained using the scan mode selected reaction monitoring (SRM). Acceptable correlations were obtained...

  20. Stacking-cyclodextrin-microchip electrokinetic chromatographic determination of gabapentinoid drugs in pharmaceutical and biological matrices.

    Science.gov (United States)

    Zeid, Abdallah M; Kaji, Noritada; Nasr, Jenny Jeehan M; Belal, Fathalla F; Baba, Yoshinobu; Walash, Mohamed I

    2017-06-23

    A facile, rapid, and highly sensitive microchip-based electrokinetic chromatographic method was developed for the simultaneous analysis of two gabapentinoid drugs, gabapentin (GPN) and pregabalin (PGN). Both drugs were first reacted with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) via nucleophilic substitution reactions to yield highly fluorescent products with λ ex/em 470/540nm. Analyses of both fluorescently labeled compounds were achieved within 200s in a poly(methyl methacrylate) (PMMA) microchip with a 30mm separation channel. Optimum separation was achieved using a borate buffer (pH 9.0) solution containing methylcellulose and β-cyclodextrin (β-CD) as buffer additives. Methylcellulose acted as a dynamic coating to prevent adsorption of the studied compounds on the inner surfaces of the microchannels, while β-CD acted as a pseudo-stationary phase to improve the separation efficiency between the labeled drugs with high resolution (Rs>7). The fluorescence intensities of the labeled drugs were measured using a light emitting diode-induced fluorescence detector at 540nm after excitation at 470nm. The sensitivity of the method was enhanced 14- and 17-fold for PGN and GPN, respectively by field-amplified stacking relative to traditional pinched injection so that it could quantify 10ngmL -1 for both analytes, with a detection limit lower than 3ngmL -1 . The developed method was efficiently applied to analyze PGN and GPN in their pharmaceutical dosage forms and in biological fluids. The extraction recoveries of the studied drugs from plasma and urine samples were more than 89% with%RSD values lower than 6.2. Copyright © 2017 Elsevier B.V. All rights reserved.