WorldWideScience

Sample records for comparative singap-mamug test

  1. Preliminary electrostatic and mechanical design of a SINGAP-MAMuG compatible accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Grando, L. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)], E-mail: luca.grando@igi.cnr.it; Dal Bello, S.; De Lorenzi, A. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Pilan, N. [DIE, Universita di Padova, Via Gradenigo 6A, I-35100 Padova (Italy); Rizzolo, A.; Zaccaria, P. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2009-06-15

    Each ITER NB injector shall provide 16.5 MW auxiliary power by accelerating a deuterium beam across a voltage of -1 MV. At present two possible alternatives for the accelerator are considered: the reference design, based on MAMuG electrostatic accelerator, where the total voltage is graded using five grids at intermediate steps of 200 kV, and the alternative concept, the SINGAP accelerator, for which the total voltage is held by one single gap. This paper focuses a preliminary feasibility study of integration of SINGAP accelerator grids into the support structure of a MAMuG type accelerator; the review or design of new electrostatic shields to improve the voltage withstanding capability of the system and the preliminary design of electrical and hydraulic connections routing from the bushing to the accelerator are also discussed. Electrostatic and mechanical analyses carried out to support the design are described in detail.

  2. Thermo-mechanical design of the SINGAP accelerator grids for ITER NB Injectors

    International Nuclear Information System (INIS)

    Agostinetti, P.; Dal Bello, S.; Palma, M.D.; Zaccaria, P.

    2006-01-01

    The SINGle Aperture - SINgle GAP (SINGAP) accelerator for ITER neutral beam injector foresees four grids for the extraction and acceleration of negative ions, instead of the seven grids of the Multi Aperture Multi Grid (MAMuG) reference configuration. Optimized geometry of the SINGAP grids (plasma, extraction, pre-acceleration, and grounded grid) was identified by CEA Association considering specific requirements for ions extraction and beam generation referring to experimental data and code simulations. This paper focuses on the thermo-hydraulic and thermo-mechanical design of the grids carried out by Consorzio RFX for the design of the first ITER NB Injector and the ITER NB Test Facility. The cooling circuit design (position and shape of the channels) and the cooling parameters (water coolant temperatures, pressure and velocity) were optimized with thermo-hydraulic and thermo-mechanical sensitivity analyses in order to satisfy the grid functional requirements (temperatures, in plane and out of plane deformations). A complete and detailed thermo-structural design assessment of the SINGAP grids was accomplished applying the structural design rules for ITER in-vessel components and considering both the reference load conditions and the maximum load provided by the power supplies. The design required a complete modelling of the grids and their support frames by means of 3D FE and CAD models. The grids were finally integrated with the support and cooling systems inside the beam source vessel. The main results of the thermo-hydraulic and thermo-mechanical analyses are presented. The open issues are then reported, mainly regarding the material properties characterization (static and fatigue tests) and the qualification of technologies for OFHC copper electro-deposition, brazing, and welding of heterogeneous materials. (author)

  3. Thermo-mechanical design of the SINGAP accelerator grids for ITER NB injectors

    Energy Technology Data Exchange (ETDEWEB)

    Agostinetti, P. [Consorzio RFX, Euratom-ENEA Association, Corso Stati Uniti 4, I35127 Padova (Italy)], E-mail: piero.agostinetti@igi.cnr.it; Dal Bello, S.; Dalla Palma, M.; Zaccaria, P. [Consorzio RFX, Euratom-ENEA Association, Corso Stati Uniti 4, I35127 Padova (Italy)

    2007-10-15

    The SINGle Aperture-SINgle GAP (SINGAP) accelerator for ITER neutral beam injector foresees four grids for the extraction and acceleration of negative ions, instead of the seven grids of the Multi-Aperture Multi-Grid (MAMuG) reference configuration. The grids have to fulfil specific requirements coming from ion extraction, beam optics and thermo-mechanical issues. This paper focuses on the thermo-hydraulic and thermo-mechanical design of the grids carried out by Consorzio RFX for the design of the first ITER NB injector and the ITER NB Test Facility. The cooling circuit design (position and shape of the channels) and the cooling parameters (water coolant temperatures, pressure and velocity) were optimized with sensitivity analyses in order to satisfy the grid functional requirements (temperatures, stresses, in plane and out of plane deformations). The design required a complete modelling of the grids and their support frames by means of 3D FE and CAD models.

  4. Design and fabrication of the 'ITER-like' SINGAP D- acceleration system

    International Nuclear Information System (INIS)

    Massmann, P.; Esch, H.P.L. de; Hemsworth, R.S.; Svensson, L.

    2005-01-01

    To demonstrate ITER NBI (1 MV, 40 A) relevant beam optics in the Cadarache 1 MV, 100 mA test bed, a new D - beam source system has been put into operation. The system retains a maximum of the ITER SINGAP key parameters, e.g. the perveance matched D - current density at 1 MeV is 20 mA/cm 2 . The accelerator parameters are identical to the ITER SINGAP design, aiming at a near parallel 1 MeV beam of 5 mrad divergence. The design is aimed at also demonstrating SINGAP 'on to off-axis' beam steering by a simple transverse displacement of the post-acceleration electrode. First beams up to 850 keV have been obtained after only 4 weeks of commissioning

  5. Study of electrostatic acceleration of H and D negative ion beams. Application to the 1 MeV SINGAP accelerator; Etude de l`acceleration electrostatique de faisceaux d`ions negatifs H / D de haute puissance. Application a l`accelerateur SINGAP de 1MeV

    Energy Technology Data Exchange (ETDEWEB)

    Bucalossi, J [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; [Paris-6 Univ., 75 (France)

    1998-04-01

    In the framework of the development of a neutral beam injection system for ITER (International Thermonuclear Experimental Reactor), the electrostatic acceleration of negative ion H/D beams up to an energy of 1 MeV has been studied. With the support of 3-D beam trajectory calculations, the limitations of the multi-aperture multi-grid acceleration concept, ITER reference concept, ar shown and the relevance of a new concept, called SINGAP, is demonstrated. In a SINGAP accelerator, beamlets are pre-accelerated with a classical triode multi-apertures system up to {approx} 50 keV. The pre-accelerated beamlets are then merged into a single beam and post-accelerated at high energy through a large SINGle APerture using one SINgle GAP. The optics of one pre-accelerated beamlet has been studied on the INCA triode accelerator at the Ecole Polytechnique. A diagnostic has been developed to measure the emittance of the pre-accelerated beamlet. A diagnostic has been developed to measure the emittance of the pre-accelerated beamlet. Values of {approx} 0.03{pi}.mrad.cm for the effective normalized emittance and {approx} 12 mrad for the minimal beam divergence have been found (Hbeams). Besides, the effects of co-extracted electrons and pressure in the transport region on the beam optics are shown and experiment is compared to beam numerical simulation. On the Cadarache 1 MeV, 100 mA, D- SINGAP accelerator, beams of 1 s pulse were produced at a level of 900 keV (without observing breakdowns between electrodes). SINGAP optics has been investigated using an infrared calorimetric beam profile diagnostic (2-D) and a neutral beam profile diagnostic (1-D). The control of the beam optics is very satisfying: a divergence of {approx} 10 mrad has been measured, and 3-D simulations and experimentation are in good agreement. (author) 117 refs.

  6. European contributions to the beam source design and R and D of the ITER neutral beam injectors

    International Nuclear Information System (INIS)

    Massmann, P.; Bayetti, P.; Bucalossi, J.

    2001-01-01

    The paper reports on the progress made by the European Home Team in strong interaction with the ITER JCT and JAERI regarding several key aspects of the beam source for the ITER injectors: integration of the SINGAP accelerator into the ITER injector design. This is a substantially simpler concept than the MAMuG accelerator of the ITER NBI 'reference design', which has potential for significant cost savings, and which avoids some of the weaknesses of the reference design such as the need for intermediate high voltage potentials from the HV power supply and pressurised gas insulation; high energy negative ion acceleration using a SINGAP accelerator; long pulse (i.e. >1000 s) negative ion source operation in deuterium; RF source development, which could reduce the scheduled maintenance of the ITER injectors (as it uses no filaments), and simplify the transmission line and the auxiliary power supplies for the ion source. (author)

  7. European contributions to the beam source design and R and D of the ITER neutral beam injectors

    International Nuclear Information System (INIS)

    Massmann, P.; Bayetti, P.; Bucalossi, J.

    1999-01-01

    The paper reports on the progress made by the European Home Team in strong interaction with the ITER JCT and JAERI regarding several key aspects of the beam source for the ITER injectors: integration of the SINGAP accelerator into the ITER injector design. This is a substantially simpler concept than the MAMuG accelerator of the ITER NBI 'reference design', which has potential for significant cost savings, and which avoids some of the weaknesses of the reference design such as the need for intermediate high voltage potentials from the HV power supply and pressurised gas insulation; high energy negative ion acceleration using a SINGAP accelerator; long pulse (i.e. >1000 s) negative ion source operation in deuterium; RF source development, which could reduce the scheduled maintenance of the ITER injectors (as it uses no filaments), and simplify the transmission line and the auxiliary power supplies for the ion source. (author)

  8. Dealing with post-accelerated electrons in the ITER SINGAP accelerator

    International Nuclear Information System (INIS)

    Esch, H. de; Hemsworth, R.S.

    2006-01-01

    Electrons formed by stripping of the negative deuterium beam can be accelerated up to 960 keV in the 1 MeV SINGAP 40 A negative ion accelerator proposed by Europe for the ITER neutral beam injectors. SINGAP accelerates 1280 pre-accelerated 40 keV deuterium beamlets to 1 MeV in a single 350 mm wide gap. At the expected gas pressure of 0.03 Pa inside the accelerator, 2.7 MW of electrons are calculated to leave the accelerator and strike various beamline components, especially the neutraliser. The accelerators of the ITER injectors are designed to produce 4 '' column '' beams which pass through the 4 vertical channels of the neutraliser. Unperturbed the accelerated electrons create small, high power density, 3.3 kW/cm 2 , spots on the leading edges of the neutraliser channels, which is far in excess of their power handling capability. The hot spots arise from the overlapping of beamlets due to the bending induced by the far field of the magnetic filter in the ion source. The proposed solution bends the electrons further downwards, redistributing the power over the neutraliser floor, a vertical electron dump perpendicular to the beam axis located below the neutraliser entrance, and the neutraliser entrance. The bending is to be effected by a magnetic field transverse to the beam direction at the exit of the post-acceleration grid. This field is created by vertical columns of permanent magnets either side of each column beam. After passing between the magnet columns, the electron beams reach the electron dump with a maximum power density of 2.1 kW/cm 2 . The peak power density on the neutraliser entrance is 1.35 kW/cm 2 and on the neutraliser floor 0.82 kW/cm 2 . Electron backscattering would reduce all the numbers by 20%. To further reduce the average power density seen by the beamline components it is proposed to sweep the electron beam in an oscillatory fashion. It is suggested that a failsafe, inexpensive, way is to use a power supply with a ripple of ± 10% to

  9. Analysis of secondary particle behavior in multiaperture, multigrid accelerator for the ITER neutral beam injector.

    Science.gov (United States)

    Mizuno, T; Taniguchi, M; Kashiwagi, M; Umeda, N; Tobari, H; Watanabe, K; Dairaku, M; Sakamoto, K; Inoue, T

    2010-02-01

    Heat load on acceleration grids by secondary particles such as electrons, neutrals, and positive ions, is a key issue for long pulse acceleration of negative ion beams. Complicated behaviors of the secondary particles in multiaperture, multigrid (MAMuG) accelerator have been analyzed using electrostatic accelerator Monte Carlo code. The analytical result is compared to experimental one obtained in a long pulse operation of a MeV accelerator, of which second acceleration grid (A2G) was removed for simplification of structure. The analytical results show that relatively high heat load on the third acceleration grid (A3G) since stripped electrons were deposited mainly on A3G. This heat load on the A3G can be suppressed by installing the A2G. Thus, capability of MAMuG accelerator is demonstrated for suppression of heat load due to secondary particles by the intermediate grids.

  10. Protections Against Grid Breakdowns in the ITER Neutral Beam Injector Power Supplies

    International Nuclear Information System (INIS)

    Bigi, M.; Toigo, V.; Zanotto, L.

    2006-01-01

    The ITER Neutral Beam Injector (NBI) is designed to deliver 16.5 MW of additional heating power to the plasma, accelerating negative ions up to -1 MV with a current up to 40 A. Two main power supplies are foreseen to feed the system: the Acceleration Grid Power Supply (AGPS), which provides power to the acceleration grids, and the Ion Source Power Supply (ISPS), devoted to supplying the ion source components. For the accelerator, two different concepts are under investigation: the MAMuG (Multiple Aperture, Multiple Gap) and the SINGAP (SINgle Aperture). During operation of the NBI, the breakdown of the acceleration grids will occur regularly; as a consequence the AGPS is expected to experience frequent load short-circuits during a pulse. For each grid breakdown, energy and current peaks are delivered from the power supply systems that could damage the grids, if not limited. In previous NBI, rated for a lower accelerating voltage, the protection system in case of grid breakdowns was based on dc circuit breakers able to quickly disconnect the power supply from the grids. In the ITER case, a similar solution is not feasible, as the voltage level is too high for present dc breaker technology. Therefore, the protection strategy has to rely on fast switch-off of the power supplies, on the optimisation of the filter elements and core snubbers placed downstream the AGPS and on the introduction of additional passive elements. However, achieving a satisfactory protection against grid breakdowns is a challenging task, as the optimisation of each single provision can result in drawbacks for other aspects of the design; for instance, the optimisation of the filter elements, obtained by reducing the filter capacitance, produces an increase of the output voltage ripple. Therefore, the design of the protections must be carried out considering all the relevant aspects of the specifications, also those that are not strictly related to the limitations of the current peaks and energy

  11. Comparative Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

     This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....... This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....

  12. Design of the 'half-size' ITER neutral beam source for the test facility ELISE

    International Nuclear Information System (INIS)

    Heinemann, B.; Falter, H.; Fantz, U.; Franzen, P.; Froeschle, M.; Gutser, R.; Kraus, W.; Nocentini, R.; Riedl, R.; Speth, E.; Staebler, A.; Wuenderlich, D.; Agostinetti, P.; Jiang, T.

    2009-01-01

    In 2007 the radio frequency driven negative hydrogen ion source developed at IPP in Garching was chosen by the ITER board as the new reference source for the ITER neutral beam system. In order to support the design and the commissioning and operating phases of the ITER test facilities ISTF and NBTF in Padua, IPP is presently constructing a new test facility ELISE (Extraction from a Large Ion Source Experiment). ELISE will be operated with the so-called 'half-size ITER source' which is an intermediate step between the present small IPP RF sources (1/8 ITER size) and the full size ITER source. The source will have approximately the width but only half the height of the ITER source. The modular concept with 4 drivers will allow an easy extrapolation to the full ITER size with 8 drivers. Pulsed beam extraction and acceleration up to 60 kV (corresponding to pre-acceleration voltage of SINGAP) is foreseen. The aim of the design of the ELISE source and extraction system was to be as close as possible to the ITER design; it has however some modifications allowing a better diagnostic access as well as more flexibility for exploring open questions. Therefore one major difference compared to the source of ITER, NBTF or ISTF is the possible operation in air. Specific requirements for RF sources as found on IPP test facilities BATMAN and MANITU are implemented [A. Staebler, et al., Development of a RF-driven ion source for the ITER NBI system, SOFT Conference 2008, Fusion Engineering and Design, 84 (2009) 265-268].

  13. Analysis of the two accelerator concepts foreseen for the neutral beam injector of the International Thermonuclear Experimental Reactor

    Directory of Open Access Journals (Sweden)

    G. Fubiani

    2009-05-01

    Full Text Available Typical high-energy negative ion electrostatic accelerators such as the ones designed for fusion applications produce a significant amount of secondary particles. These particles may originate from coextracted electrons, which flow from the ion source, impacting the accelerator grids or as by-products of collisions between accelerated negative ions and the residual background gas, in the accelerator. Secondary emission particles may carry a non-negligible power and consequently must be precisely studied. The electrostatic-accelerator-Monte-Carlo-simulation code (EAMCC [G. Fubiani et al., Phys. Rev. ST Accel. Beams 11, 014202 (2008PRABFM1098-440210.1103/PhysRevSTAB.11.014202] was developed in order to provide a three-dimensional characterization of power and current deposition on all parts of the accelerator. The code includes all the relevant physics associated with secondary emission processes and consequently may be used as a tool for design improvement. In this paper, the two accelerator designs considered for the International Thermonuclear Experimental Reactor, that is, the multiaperture-multigrid and the single gap single aperture (SINGAP designs, are discussed and their predicted performances compared. Simulations have been compared with measurements on prototype accelerators of the SINGAP type. Reasonable agreement between EAMCC calculations and measurements of backstreaming ions and transmitted electrons was found.

  14. Comparative Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    This document includes the specification on the IEA task of evaluation building energy simulation computer programs for the Double Skin Facades (DSF) constructions. There are two approaches involved into this procedure, one is the comparative approach and another is the empirical one. In the comp....... In the comparative approach the outcomes of different software tools are compared, while in the empirical approach the modelling results are compared with the results of experimental test cases. The comparative test cases include: ventilation, shading and geometry....

  15. CompareTests-R package

    Science.gov (United States)

    CompareTests is an R package to estimate agreement and diagnostic accuracy statistics for two diagnostic tests when one is conducted on only a subsample of specimens. A standard test is observed on all specimens.

  16. Comparing diagnostic tests on benefit-risk.

    Science.gov (United States)

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  17. Manipulator comparative testing program

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Sundstrom, E.; Herndon, J.N.; Fujita, Y.; Maeda, M.

    1986-01-01

    The Manipulator Comparative Testing Program examined differences among manipulator systems from the United States and Japan. The manipulator systems included the Meidensha BILARM 83A, the Model M-2 of Central Research Laboratories Division of Sargent Industries (CRL), and the GCA Corporation PaR Systems Model 6000. The site of testing was the Remote Operations Maintenance Demonstration (ROMD) facility, operated by the Fuel Recycle Division in the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL). In all stages of testing, operators using the CRL Model M-2 manipulator had consistently lower times to completion and error rates than they did using other machines. Performance was second best with the Meidensha BILARM 83A in master-slave mode. Performance with the BILARM in switchbox mode and the PaR 6000 manipulator was approximately equivalent in terms of criteria recorded in testing. These data show no impact of force reflection on task performance

  18. Statistical tests to compare motif count exceptionalities

    Directory of Open Access Journals (Sweden)

    Vandewalle Vincent

    2007-03-01

    Full Text Available Abstract Background Finding over- or under-represented motifs in biological sequences is now a common task in genomics. Thanks to p-value calculation for motif counts, exceptional motifs are identified and represent candidate functional motifs. The present work addresses the related question of comparing the exceptionality of one motif in two different sequences. Just comparing the motif count p-values in each sequence is indeed not sufficient to decide if this motif is significantly more exceptional in one sequence compared to the other one. A statistical test is required. Results We develop and analyze two statistical tests, an exact binomial one and an asymptotic likelihood ratio test, to decide whether the exceptionality of a given motif is equivalent or significantly different in two sequences of interest. For that purpose, motif occurrences are modeled by Poisson processes, with a special care for overlapping motifs. Both tests can take the sequence compositions into account. As an illustration, we compare the octamer exceptionalities in the Escherichia coli K-12 backbone versus variable strain-specific loops. Conclusion The exact binomial test is particularly adapted for small counts. For large counts, we advise to use the likelihood ratio test which is asymptotic but strongly correlated with the exact binomial test and very simple to use.

  19. Comparing survival curves using rank tests

    NARCIS (Netherlands)

    Albers, Willem/Wim

    1990-01-01

    Survival times of patients can be compared using rank tests in various experimental setups, including the two-sample case and the case of paired data. Attention is focussed on two frequently occurring complications in medical applications: censoring and tail alternatives. A review is given of the

  20. Comparative tests of bench equipment for fuel control system testing of gas-turbine engine

    Science.gov (United States)

    Shendaleva, E. V.

    2018-04-01

    The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.

  1. Framework for a Comparative Accelerated Testing Standard for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Wohlgemuth, J.; Yamamichi, M.; Sample, T.; Miller, D.; Meakin, D.; Monokroussos, C.; TamizhMani, M.; Kempe, M.; Jordan, D.; Bosco, N.; Hacke, P.; Bermudez, V.; Kondo, M.

    2013-08-01

    As the photovoltaic industry has grown, the interest in comparative accelerated testing has also grown. Private test labs offer testing services that apply greater stress than the standard qualification tests as tools for differentiating products and for gaining increased confidence in long-term PV investments. While the value of a single international standard for comparative accelerated testing is widely acknowledged, the development of a consensus is difficult. This paper strives to identify a technical basis for a comparative standard.

  2. Comparing Tests for Diabetes and Prediabetes: A Quick Reference Guide

    Science.gov (United States)

    ... Urinary Tract Imaging Urodynamic Testing Virtual Colonoscopy Diabetes & Prediabetes Tests This fact sheet compares the following tests: ... test Confirming Diagnosis of Type 2 Diabetes and Prediabetes Diagnosis must be confirmed unless symptoms are present. ...

  3. Chi-square tests for comparing weighted histograms

    International Nuclear Information System (INIS)

    Gagunashvili, N.D.

    2010-01-01

    Weighted histograms in Monte Carlo simulations are often used for the estimation of probability density functions. They are obtained as a result of random experiments with random events that have weights. In this paper, the bin contents of a weighted histogram are considered as a sum of random variables with a random number of terms. Generalizations of the classical chi-square test for comparing weighted histograms are proposed. Numerical examples illustrate an application of the tests for the histograms with different statistics of events and different weighted functions. The proposed tests can be used for the comparison of experimental data histograms with simulated data histograms as well as for the two simulated data histograms.

  4. The minimal ice water caloric test compared with established vestibular caloric test procedures.

    Science.gov (United States)

    Schmäl, Frank; Lübben, Björn; Weiberg, Kerstin; Stoll, Wolfgang

    2005-01-01

    Caloric testing of the vestibular labyrinth is usually performed by classical caloric test procedures (CCTP) using water warmed to 30 degrees C and 44 degrees C. Ice water irrigation (4 degrees C) is usually not performed, although it might be useful as a bedside test. To verify the validity of the Minimal Ice Water Caloric Test (MIWCT), comparative video-oculographic investigations were performed in 22 healthy subjects using ice water (0.5 ml, 1.0 ml, 2 ml), CCTP, and cold air (27 degrees C). Frequency, amplitude, slow phase velocity (SPV), the onset, and the duration of nystagmus were documented. After addition of three ice cubes, the temperature of conventional tap water (16 degrees C) fell within 13 min to 4 degrees C. In pessimum position the subjects demonstrated no nystagmus response. Compared to CCTP, MIWCT was associated with a significantly later onset of nystagmus and a significant prolongation of the nystagmus reaction. In contrast to air stimulation (27 degrees C), a significant Spearman's correlation was noted between MIWCT (1 and 2 ml) and established CCTP in respect of essential nystagmus parameters (frequency, amplitude and SPV). Furthermore, MIWCT (0.5 and 1 ml) showed a higher sensitivity and specificity with regard to the detection of canal paresis based on Jongkees' formula compared to stimulation with air 27 degrees C. Thus, MIWCT appears to be a suitable procedure for bedside investigation of vestibular function outside the vestibular laboratory, e.g. in a hospital ward, where bedridden patients with vertigo occasionally require vestibular testing.

  5. The Insulation Structure of the 1 Megavolt Transmission Line for the ITER Neutral Beam Injector

    International Nuclear Information System (INIS)

    Lorenzi, A. de; Grando, L.; Gobbo, R; Pesavento, G.; Bettini, P.; Specogna, R.; Trevisan, F.

    2006-01-01

    The paper describes the studies and the tests for the development of the insulation structure of the 1 MV-50 A Gas Insulated (SF 6 ) Line of the ITER NBI in the SINGAP configuration. Basically, the Transmission Line for the SinGap configuration consists of a coaxial conductor with the inner electrode polarized at the negative value of 1 MV dc. Despite Transmission Line belongs to the Gas Insulated Switchgear (GIS) family, whose technology is nowadays mature, the design of spacers (usually epoxy post and conical type) for High Voltage DC with the same degree of reliability of spacer for High Voltage AC is far away to be attained, due to the substantial difference between AC and DC voltage electric field configuration and insulation behavior at Epoxy-SF 6 interface. Furthermore, the occurrence of very frequent short circuits during the NBI operation introduces further elements of uncertainty in the design of the insulation structure. The first step was then to assess the capability of standard epoxy spacers to withstand DC voltage with frequent short circuits, in order to determine if the choice of the material is suitable for such an application; a test circuit was set up, with the possibility to generate 200 kV DC and to produce a short-circuit every 15'. The system with the spacers was pressurized with SF 6 at 0.3 MPa. For the interpretation of the experimental results, the spacer has been modeled with commercial (ANSYS TM FEM) and research (Cell Method) numerical codes in order to evaluate both the capacitive and resistive electric field distributions. Once assessed the possibility of using epoxy compounds for the spacer construction, the post and cone spacers have been designed taking into consideration various cases, like electrostatic field configuration, resistive distribution for homogeneous and skin conductivity of the spacer, and for high SF 6 conductivity. In these cases the optimization of the triple point screening has been evaluated, leading to

  6. Accuracy of non-invasive 13C-urea breath test compared to invasive tests for helicobacter pylori detection

    International Nuclear Information System (INIS)

    Bilal, R.; Khaar, B.; Omar, M.; Qureshi, T.Z.; Ahmed, T.; Latif, Z.; Jaffery, I.; Omar, M.

    2007-01-01

    To compare the sensitivity, specificity and Positive Predictive Value (PPV) of histology, Campylobacter-Like Organism (CLO) test, culture and 13C-Urea Breath Test (UBT) for the diagnosis of Helicobacter pylori infection. District Headquarter Hospital, Rawalpindi, Military Hospital, Rawalpindi and Pakistan Institute of Science and Technology (PINSTECH), Nilore, Islamabad from June 2002 to 2003. Three mucosal biopsy specimens were obtained during endoscopy of 90 symptomatic patients. Histology, CLO test and culture were performed on these specimens. Breath samples for 13C-UBT were collected and sent to RIAD, PINSTECH on the same day for isotope ratio mass spectrometry. For analysis purpose, each of the tests was fixed as the gold standard in turn and the others were then compared against it. In addition, any two as well as any three positive tests were then set as the gold standard and the other tests compared against them to calculate the sensitivity, specificity, accuracy and PPV of other tests. Urea breath test had the highest sensitivity, ranging from 95 to 100%, against all the gold standards with specificity ranging from 55 to 100%, whereas the sensitivity of histological examination was around 98% but it had comparatively lower specificity (49-89%). The CLO test had a sensitivity range of 86-100% and specificity of 67-100%. Culture had the minimum sensitivity (59-70%) but had highest specificity (96-100%) against all the gold standards. Age and gender had no effect on p-value of each test or in combination. The urea breath test has shown the highest ability to detect the organism with 95-100% sensitivity in symptomatic individuals and specificity, which is comparable to other tests. (author)

  7. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  8. Repeatability of an automated Landolt C test, compared with the early treatment of diabetic retinopathy study (ETDRS) chart testing.

    Science.gov (United States)

    Ruamviboonsuk, Paisan; Tiensuwan, Montip; Kunawut, Catleya; Masayaanon, Patcharapim

    2003-10-01

    To evaluate the repeatability of visual acuity scores from the automated test and compare them with the Early Treatment of Diabetic Retinopathy Study (ETDRS) chart. Instrument validation study based on a model of repeatability study in two observations. SMETHODS: a prospective, clinic-based, comparative study. A total of 206 participants without ocular diseases and refractive errors in their right eyes were randomly enrolled in the automated group in which 107 participants performed the automated test and the ETDRS group in which 99 participants read the ETDRS chart. All participants were tested with only their right eyes without corrections at 4 meters and came back to have the same tests 1 week later. The automated test used the Landolt rings as optotypes and was conducted by a low-ended personal computer with a 15-inch monitor and a wireless keyboard. The "letter" score calculated by counting every correct response to optotypes, and the "threshold curve" score interpreted from the optotype size at the midpoint of a visual acuity threshold curve. The 95% confidence interval of test-retest of visual acuity scores from the automated test are comparable to the ETDRS chart (.143 compared with.125 for letter scores,.145 compared with.122 for threshold curve scores). The score repeatabilities, calculated from the standard deviations of test-retest, from the automated test are also comparable to the ETDRS chart (.201 compared with.177 for letter scores,.206 compared with.172 for threshold curve scores). All comparisons demonstrated no statistical difference (P >.05). The automated testing system in this study enables practical measuring visual acuity by the Landolt rings. The system's repeatability, which is comparable to the ETDRS chart, supports its role as an alternative tool for measuring outcome in new clinical research. Its ability to practically generate visual acuity threshold curves may also be useful in future clinical research studies.

  9. Results from preliminary experiments of the 1 MeV 0.1 A D- project at CEA-Cadarache

    International Nuclear Information System (INIS)

    Simonin, A.; Fumelli, M.; Jequier, F.; Pamela, J.; Bucalossi, J.; Bottereau, J.M.; Brugnetti, R.

    1994-01-01

    A 1 MeV 0.1 A D - -beam acceleration experiment under preparation is described. It will study a simplified concept of negative ion beam electrostatic accelerator called SINGAP. Some critical HV components, like a large MV bushing or protection systems against the HV vacuum breakdowns will also be tested. The experiments reported here have been conducted during the preparatory phase of this MeV project. A negative ion source was developed and produced 1 A D - beams and j(D - )=12 mA/cm 2 beams. A new type of extraction grid was designed which traps almost 100% of the stray electrons extracted from the source plasma. A new emittance diagnostic has been successfully tested with 60-100 keV D - beams. A 1 MV 120 mA Haefely power supply has been moved from KfK, adapted and operated on a resistive load at the nominal operating characteristics. (author) 5 refs.; 6 figs

  10. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  11. A Powerful Test for Comparing Multiple Regression Functions.

    Science.gov (United States)

    Maity, Arnab

    2012-09-01

    In this article, we address the important problem of comparison of two or more population regression functions. Recently, Pardo-Fernández, Van Keilegom and González-Manteiga (2007) developed test statistics for simple nonparametric regression models: Y(ij) = θ(j)(Z(ij)) + σ(j)(Z(ij))∊(ij), based on empirical distributions of the errors in each population j = 1, … , J. In this paper, we propose a test for equality of the θ(j)(·) based on the concept of generalized likelihood ratio type statistics. We also generalize our test for other nonparametric regression setups, e.g, nonparametric logistic regression, where the loglikelihood for population j is any general smooth function [Formula: see text]. We describe a resampling procedure to obtain the critical values of the test. In addition, we present a simulation study to evaluate the performance of the proposed test and compare our results to those in Pardo-Fernández et al. (2007).

  12. Comparative study of durability test methods for pellets and briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Temmerman, Michaeel; Rabier, Fabienne [Centre wallon de Recherches agronomiques (CRA-W), 146, chaussee de Namur, B-5030, Gembloux (Belgium); Jensen, Peter Daugbjerg [Forest and Landscape, The Royal Veterinary and Agricultural University, Rolighedsvej 23, DK-1958 Frederiksberg C (Denmark); Hartmann, Hans; Boehm, Thorsten [Technologie- und Foerderzentrum fuer Nachwachsende Rohstoffe-TFZ, Schulgasse 18, D-94315 Straubing (Germany)

    2006-11-15

    Different methods for the determination of the mechanical durability (DU) of pellets and briquettes were compared by international round robin tests including different laboratories. The DUs of five briquette and 26 pellet types were determined. For briquettes, different rotation numbers of a prototype tumbler and a calculated DU index are compared. For pellets testing, the study compares two standard methods, a tumbling device according to ASAE S 269.4, the Lignotester according to ONORM M 7135 and a second tumbling method with a prototype tumbler. For the tested methods, the repeatability, the reproducibility and the required minimum number of replications to achieve given accuracy levels were calculated. Additionally, this study evaluates the relation between DU and particle density. The results show for both pellets and briquettes, that the measured DU values and their variability are influenced by the applied method. Moreover, the variability of the results depend on the biofuel itself. For briquettes of DU above 90%, five replications lead to an accuracy of 2%, while 39 replications are needed to achieve an accuracy of 10%, when briquettes of DU below 90% are tested. For pellets, the tumbling device described by the ASAE standard allows to reach acceptable accuracy levels (1%) with a limited number of replications. Finally, for the tested pellets and briquettes no relation between DU and particle density was found. (author)

  13. Comparative test on nuclide migration in aerated zone

    International Nuclear Information System (INIS)

    Li Shushen; Zhao Yingjie; Wu Qinghua; Wang Zhiming; Hao Janzhong; Ji Shaowei; Guo Liangtian; Guo Zhiming

    2002-01-01

    In order to study the influence of different tracer source layer material on nuclide migration behavior, the comparative test on stable elements Sr, Nd and Ce migration in aerated loess zone was carried out using loess and arenaceous quartz as the tracer source layer materials respectively. The test lasted 470 days. During the test, four times of sampling were done. The testing results indicate that under artificial sprinkling of 5 mm/h and 3 h/d, Nd and Ce not only in loess tracer source layer but also in arenaceous quartz tracer source layer did not obviously downwards migrated. Concentration peak of Sr for loess layer migrated down about 15 cm in 470 d (mass center moved down about 10 cm) but for arenaceous quartz layer the concentration peak of Sr did not obviously migrated down (mass center moved down about 2.7 cm). The test results show that very thin arenaceous quartz layer with thickness of 7 mm is also able to shield unsaturated water flow obviously. This is the main reason why the nuclides in arenaceous quartz layer migrate down slowly

  14. Comparative Hepatotoxicity Test of Cadmium and Lead in Rats ...

    African Journals Online (AJOL)

    Background: Adverse environmental impacts include contamination of water, soil, and phytotoxicity from excessive heavy metals dispersed from mines and smelter sites leading to potential risk to human health. This study investigated the comparative hepatotoxicity test of mining pond waters used for domestic purposes in ...

  15. Waste water processing technology for Space Station Freedom - Comparative test data analysis

    Science.gov (United States)

    Miernik, Janie H.; Shah, Burt H.; Mcgriff, Cindy F.

    1991-01-01

    Comparative tests were conducted to choose the optimum technology for waste water processing on SSF. A thermoelectric integrated membrane evaporation (TIMES) subsystem and a vapor compression distillation subsystem (VCD) were built and tested to compare urine processing capability. Water quality, performance, and specific energy were compared for conceptual designs intended to function as part of the water recovery and management system of SSF. The VCD is considered the most mature and efficient technology and was selected to replace the TIMES as the baseline urine processor for SSF.

  16. A comparative test of phylogenetic diversity indices.

    Science.gov (United States)

    Schweiger, Oliver; Klotz, Stefan; Durka, Walter; Kühn, Ingolf

    2008-09-01

    Traditional measures of biodiversity, such as species richness, usually treat species as being equal. As this is obviously not the case, measuring diversity in terms of features accumulated over evolutionary history provides additional value to theoretical and applied ecology. Several phylogenetic diversity indices exist, but their behaviour has not yet been tested in a comparative framework. We provide a test of ten commonly used phylogenetic diversity indices based on 40 simulated phylogenies of varying topology. We restrict our analysis to a topological fully resolved tree without information on branch lengths and species lists with presence-absence data. A total of 38,000 artificial communities varying in species richness covering 5-95% of the phylogenies were created by random resampling. The indices were evaluated based on their ability to meet a priori defined requirements. No index meets all requirements, but three indices turned out to be more suitable than others under particular conditions. Average taxonomic distinctness (AvTD) and intensive quadratic entropy (J) are calculated by averaging and are, therefore, unbiased by species richness while reflecting phylogeny per se well. However, averaging leads to the violation of set monotonicity, which requires that species extinction cannot increase the index. Total taxonomic distinctness (TTD) sums up distinctiveness values for particular species across the community. It is therefore strongly linked to species richness and reflects phylogeny per se weakly but satisfies set monotonicity. We suggest that AvTD and J are best applied to studies that compare spatially or temporally rather independent communities that potentially vary strongly in their phylogenetic composition-i.e. where set monotonicity is a more negligible issue, but independence of species richness is desired. In contrast, we suggest that TTD be used in studies that compare rather interdependent communities where changes occur more gradually by

  17. Metabolic and clinical comparative analysis of treadmill six-minute walking test and cardiopulmonary exercise testing in obese and eutrophic women

    Directory of Open Access Journals (Sweden)

    Luciana Di Thommazo-Luporini

    Full Text Available BACKGROUND: Impaired exercise tolerance is directly linked to decreased functional capacity as a consequence of obesity. OBJECTIVES: To analyze and compare the cardiopulmonary, metabolic, and perceptual responses during a cardiopulmonary exercise test (CPX and a treadmill six-minute walking test (tread6MWT in obese and eutrophic women. METHOD: Twenty-nine female participants, aged 20-45 years were included. Fourteen were allocated to the obese group and 15 to the eutrophic group. Anthropometric measurements and body composition assessment were performed. RESULTS: In both tests, obese women presented with significantly higher absolute oxygen uptake, minute ventilation, and systolic and diastolic blood pressure; they also presented with lower speed, distance walked, and oxygen uptake corrected by the weight compared to eutrophics. During the maximal exercise test, perceived dyspnea was greater and the respiratory exchange ratio was lower in obese subjects compared to eutrophics. During the submaximal test, carbon dioxide production, tidal volume, and heart rate were higher in obese subjects compared to eutrophic women. When analyzing possible correlations between the CPX and the tread6MWT at peak, there was a strong correlation for the variable heart rate and a moderate correlation for the variable oxygen uptake. The heart rate obtained in the submaximal test was able to predict the one obtained in the maximal test. Bland-Altman plots demonstrated the agreement between both tests to identify metabolic and physiological parameters at peak exercise. CONCLUSIONS: The six-minute walking test induced ventilatory, metabolic, and cardiovascular responses in agreement with the maximal testing. Thus, the six-minute walking test proves to be important for functional evaluation in the physical therapy routine.

  18. Comparative product testing of children's restraint systems, with inclusion of side-collision tests

    Energy Technology Data Exchange (ETDEWEB)

    Goerlitz, H. [Stiftung Warentest, Berlin (Germany); Noeske, V. [DEKRA Dresden (Germany)

    2001-07-01

    Stiftung Warentest has conducted comparative product testing for Group 0.. III child car seats to evaluate accident protection, handling, comfort of the seats, and safety against faulty use. The tests that were conducted were intended to provide assessment of product quality. Owing to great reader interest, tests conducted on child car seats have become well established for a considerable number of years now. They enjoy esteemed status, for example, in our magazine test. Stiftung Warentest conducted its first tests on children's restraint system many years ago: in May of 1968. The great interest in this topic, as evidenced by widespread feedback from readers, justifies the high costs occasioned by the dynamic testing of children's restraint systems. The popularity of this topic leads to greater sales of the particular issues of the magazine test - which carries no advertising - and at least compensates for most of the added costs necessary for dynamic collision testing. It is not generally well known that Stiftung Warentest covers approximately 90% of its budget from the sales of its two magazines test and Finanztest, and of its other special publications. The annual subsidy by the German government is relatively small. The national subsidy is intended to compensate for the loss of revenue from the exclusion of advertising. (orig.)

  19. The comparative performance of the single intradermal test and the single intradermal comparative tuberculin test in Irish cattle, using tuberculin PPD combinations of differing potencies.

    Science.gov (United States)

    Good, M; Clegg, T A; Costello, E; More, S J

    2011-11-01

    In national bovine tuberculosis (BTB) control programmes, testing is generally conducted using a single source of bovine purified protein derivative (PPD) tuberculin. Alternative tuberculin sources should be identified as part of a broad risk management strategy as problems of supply or quality cannot be discounted. This study was conducted to compare the impact of different potencies of a single bovine PPD tuberculin on the field performance of the single intradermal comparative tuberculin test (SICTT) and single intradermal test (SIT). Three trial potencies of bovine PPD tuberculin, as assayed in naturally infected bovines, namely, low (1192IU/dose), normal (6184IU/dose) and high (12,554IU/dose) were used. Three SICTTs (using) were conducted on 2102 animals. Test results were compared based on reactor-status and changes in skin-thickness at the bovine tuberculin injection site. There was a significant difference in the number of reactors detected using the high and low potency tuberculins. In the SICTT, high and low potency tuberculin detected 40% more and 50% fewer reactors, respectively, than normal potency tuberculin. Furthermore, use of the low potency tuberculin in the SICTT failed to detect 20% of 35 animals with visible lesions, and in the SIT 11% of the visible lesion animals would have been classified as negative. Tuberculin potency is critical to the performance of both the SICTT and SIT. Tuberculin of different potencies will affect reactor disclosure rates, confounding between-year or between-country comparisons. Independent checks of tuberculin potency are an important aspect of quality control in national BTB control programmes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Comparative activity of carbapenem testing (the COMPACT study in Turkey

    Directory of Open Access Journals (Sweden)

    Leblebicioglu Hakan

    2012-02-01

    Full Text Available Abstract Background Recent evidence indicates that Gram-negative bacterial pathogens, the most common of which are Pseudomonas spp., Enterobacteriaceae, and Acinetobacter baumannii, are frequent causes of hospital-acquired infections. This study aims to evaluate the in vitro activity of doripenem and comparator carbapenem antibiotics against Gram-negative clinical isolates collected from COMParative Activity of Carbapenem Testing (COMPACT study centres in Turkey. Methods Ten centres in Turkey were invited to submit Pseudomonas aeruginosa, Enterobacteriaceae, and other Gram-negative isolates from intensive care unit (ICU/non-ICU patients with complicated intra-abdominal infections, bloodstream infections, or nosocomial pneumonia, including ventilator-associated pneumonia, between May and October 2008. Susceptibility was determined by each centre using E-test. A central laboratory performed species confirmation as well as limited susceptibility and quality-control testing. Results Five hundred and ninety six isolates were collected. MIC90 values for doripenem, meropenem, and imipenem, respectively, were 32, ≥ 64, and ≥ 64 mg/L against Pseudomonas spp.; 0.12, 0.12, and 0.5 mg/L against Enterobacteriaceae; and ≥ 64 mg/L for each against other Gram-negative isolates. In determining the susceptibility of hospital isolates of selected Gram-negative pathogens to doripenem, imipenem, and meropenem, we found that against all pathogens combined, the MIC90 for ICU compared with non-ICU isolates was higher. Conclusions Doripenem showed similar or slightly better activity than meropenem and better activity than imipenem against the Gram-negative pathogens collected in Turkey.

  1. [Comparative study of 3 types of lancets for performing prick tests].

    Science.gov (United States)

    Montalvo, A; Martín, S; Mesa, A; Cortés, C; Rodríguez, M; Laso, M T

    1996-01-01

    Skin Prick Test is considered the cutaneous test of choice in rutinary clinical practice as well as in research. In the last 15 years a large number of lancets for puncture test have been developed looking for a higher level of standardisation and reproducibility. We have compared three lancets, two of them, NeoAbelló (NA) and Dome/Hollister Stier (DHS), used in puncture test and a third one, Blood Lancet (BL), in the modified prick test. Twenty-two patients sensitised to Phleum pratense were tested with the three lancets at three extract concentrations and histamine 10 mg/mL in duplicate. We compared their wheal sizes by means of parallel line assay, their reproducibility, frequency of bleeding wheals, the disturbance for the patient and the correlation between specific IgE and skin response. Wheal size was similar for puncture tests (DHS and NA lancets) and significatively lower than BL, being necessary to increase 1.9 times the extract concentration when using DHS and NA lancets to achieve the same wheal size than when using BL lancets (p < 0.01). Reproducibility with histamine was similar with the three lancets while with the extract was somehow better with puncture tests but without statistical significance. Bleeding was significantly more frequent with BL although this did not influence the results. Less pain was obtained with BL. Finally, correlation with specific IgE was slightly significant for NA and very similar for the other two. With these results in mind we think that any of the three lancets is valid for the diagnostic of the allergic patient. Nevertheless, puncture tests are probably the most suitable at a research level.

  2. Comparative effectiveness of 50g glucose challenge test and risk ...

    African Journals Online (AJOL)

    ... of 50g glucose challenge test and risk factor based screening in detection of ... Mean maternal and gestational ages at recruitment were 30.8+1.2 years and ... Predictive Value, PPV - 20%) compared to risk factors only (PPV- 11.1%).

  3. Comparative study of in-situ filter test methods

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1981-01-01

    Available methods of testing high efficiency particulate aerosol (HEPA) filters in-situ have been reviewed. In order to understand the relationship between the results produced by different methods a selection has been compared. Various pieces of equipment for generating and detecting aerosols have been tested and their suitability assessed. Condensation-nuclei, DOP (di-octyl phthalate) and sodium-flame in-situ filter test methods have been studied, using the 500 cfm (9000 m 3 /h) filter test rig at Harwell and in the field. Both the sodium-flame and DOP methods measure the penetration through leaks and filter material. However the measured penetration through filtered leaks depends on the aerosol size distribution and the detection method. Condensation-nuclei test methods can only be used to measure unfiltered leaks since condensation nuclei have a very low penetration through filtered leaks. A combination of methods would enable filtered and unfiltered leaks to be measured. A condensation-nucleus counter using n-butyl alcohol as the working fluid has the advantage of being able to detect any particle up to 1 μm in diameter, including DOP, and so could be used for this purpose. A single-particle counter has not been satisfactory because of interference from particles leaking into systems under extract, particularly downstream of filters, and because the concentration of the input aerosol has to be severely limited. The sodium-flame method requires a skilled operator and may cause safety and corrosion problems. The DOP method using a total light scattering detector has so far been the most satisfactory. It is fairly easy to use, measures reasonably low values of penetration and gives rapid results. DOP has had no adverse effect on HEPA filters over a long series of tests

  4. An investigation of the statistical power of neutrality tests based on comparative and population genetic data

    DEFF Research Database (Denmark)

    Zhai, Weiwei; Nielsen, Rasmus; Slatkin, Montgomery

    2009-01-01

    In this report, we investigate the statistical power of several tests of selective neutrality based on patterns of genetic diversity within and between species. The goal is to compare tests based solely on population genetic data with tests using comparative data or a combination of comparative...... and population genetic data. We show that in the presence of repeated selective sweeps on relatively neutral background, tests based on the d(N)/d(S) ratios in comparative data almost always have more power to detect selection than tests based on population genetic data, even if the overall level of divergence...... selection. The Hudson-Kreitman-Aguadé test is the most powerful test for detecting positive selection among the population genetic tests investigated, whereas McDonald-Kreitman test typically has more power to detect negative selection. We discuss our findings in the light of the discordant results obtained...

  5. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test.

    Science.gov (United States)

    Nkrumah, Bernard; Acquah, Samuel Ek; Ibrahim, Lukeman; May, Juergen; Brattig, Norbert; Tannich, Egbert; Nguah, Samuel Blay; Adu-Sarkodie, Yaw; Huenger, Frank

    2011-05-23

    About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and

  6. Comparative analysis of two rapid diagnostic tests for diagnosis of ...

    African Journals Online (AJOL)

    This study aims at comparing the diagnostic efficiencies of two commercially available kits for detecting Plasmodium falciparum infection in urine and blood of febrile patients for malaria diagnosis. This was an observational study in which matched blood and urine from symptomatic patients were tested for malaria using two ...

  7. Comparing the Effects of Elementary Music and Visual Arts Lessons on Standardized Mathematics Test Scores

    Science.gov (United States)

    King, Molly Elizabeth

    2016-01-01

    The purpose of this quantitative, causal-comparative study was to compare the effect elementary music and visual arts lessons had on third through sixth grade standardized mathematics test scores. Inferential statistics were used to compare the differences between test scores of students who took in-school, elementary, music instruction during the…

  8. Investigation into the comparative severity of practical thermal test procedures

    International Nuclear Information System (INIS)

    Shultz, K.R.; White, M.C.; Gordon, G.

    In the advisory material for the application of the IAEA Transport Regulations three methods for determining whether a type B radioactive material packaging can withstand hypothetical fire conditions are presented. These comprise an open fire test and two tests involving exposure of the packaging in a furnace. The first furnace test (method I) uses a materials testing type of furnace and the second (method II) uses a heat-treatment furnace. Under method I the packaging is heated for 35 minutes from ambient temperature by firing the furnace so that its temperature increases in accordance with an ISO standard fire curve; under method II the heating is for 30 minutes at 800 0 C. Tests were carried out to detarmine if these tests were of comparable severity, and on which temperature the control of furnace firing in method I should be based. It was concluded that method II was the more severe test, and that furance wall temperatues are the dominant factor in determining heat exchange to specimens in the furnaces used. Furnace walls should meet or exceed the standard fire curve set out in the ISO standard. The characteristics of the furnances and specimens were not sufficiently understood to be able to predict the behaviour of the specimens

  9. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory-based testing.

    Science.gov (United States)

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M; Hampton, Robert R

    2013-05-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory-housed monkeys (Laboratory). The Field station animals shared access to four touch-screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching-to-sample memory test. Despite the differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments.

  10. Topical Knowledge in L2 Speaking Assessment: Comparing Independent and Integrated Speaking Test Tasks

    Science.gov (United States)

    Huang, Heng-Tsung Danny; Hung, Shao-Ting Alan; Plakans, Lia

    2018-01-01

    Integrated speaking test tasks (integrated tasks) provide reading and/or listening input to serve as the basis for test-takers to formulate their oral responses. This study examined the influence of topical knowledge on integrated speaking test performance and compared independent speaking test performance and integrated speaking test performance…

  11. The US Army Foreign Comparative Test fuel cell program

    Science.gov (United States)

    Bostic, Elizabeth; Sifer, Nicholas; Bolton, Christopher; Ritter, Uli; Dubois, Terry

    The US Army RDECOM initiated a Foreign Comparative Test (FCT) Program to acquire lightweight, high-energy dense fuel cell systems from across the globe for evaluation as portable power sources in military applications. Five foreign companies, including NovArs, Smart Fuel Cell, Intelligent Energy, Ballard Power Systems, and Hydrogenics, Inc., were awarded competitive contracts under the RDECOM effort. This paper will report on the status of the program as well as the experimental results obtained from one of the units. The US Army has interests in evaluating and deploying a variety of fuel cell systems, where these systems show added value when compared to current power sources in use. For low-power applications, fuel cells utilizing high-energy dense fuels offer significant weight savings over current battery technologies. This helps reduce the load a solider must carry for longer missions. For high-power applications, the low operating signatures (acoustic and thermal) of fuel cell systems make them ideal power generators in stealth operations. Recent testing has been completed on the Smart Fuel Cell A25 system that was procured through the FCT program. The "A-25" is a direct methanol fuel cell hybrid and was evaluated as a potential candidate for soldier and sensor power applications.

  12. The Estimation of Knowledge Solidity Based on the Comparative Analysis of Different Test Results

    Directory of Open Access Journals (Sweden)

    Y. K. Khenner

    2012-01-01

    Full Text Available At present, the testing techniques of knowledge estimation are widely spread in educational system. However, this method is seriously criticized including its application to the Unified State Examinations. The research is aimed at studying the limitations of testing techniques. The authors recommend a new way of knowledge solid- ity estimation bases on the comparative results analysis of various kinds of tests. While testing the large group of students, the authors found out that the results of the closed and open tests substantially differ. The comparative analysis demonstrates that the open tests assessment of the knowledge solidity is more adequate than that of the closed ones. As the research is only based on a single experiment, the authors recommend using this method further, substantiating the findings concerning the differences in tests results, and analyzing the advantages and disadvantages of the tests in question. 

  13. Efficacy comparative of different laboratory test reagents for hepatitis C virus antibody

    Directory of Open Access Journals (Sweden)

    GUO Feibo

    2016-09-01

    Full Text Available Objective To investigate the effects of different laboratory test reagents for hepatitis C virus (HCV antibody through a comparative analysis. Methods A total of 207 samples which tested positive by four anti-HCV screening reagents commonly used in the laboratories in China (Kehua, Xinchuang, Wantai, and Abbott were included. HCV RNA nucleic acid amplification (NAT was performed, and if NAT results were negative, recombinant immunoblot assay (RIBA was performed for further confirmation. The test results of these four screening reagents were compared, and their S/CO values and true positive rates were analyzed. Results Of all the 205 samples testing positive by any one reagent, 191 (93.2% tested positive by the four reagents, and 14 (6.8% were tested inconsistently by the four reagents. The positive predictive values of Xinchuang, Kehua, Wantai, and Abbott reagents were 88.2% (180/204, 93.8% (180/192, 91.4% (180/197, and 90.0% (180/200, respectively. The S/CO thresholds with a positive predictive value of ≥95% for Xinchuang, Kehua, Wantai, and Abbott reagents were 9.0, 4.0, 5.0, and 7.0, respectively. Conclusion Xinchuang, Kehua, Wantai, and Abbott reagents have significantly different S/CO thresholds with a positive predictive value of ≥95%, which are significantly different from those in other domestic laboratories. Each laboratory should establish an applicable S/CO threshold with a positive predictive value of ≥95%, in order to reduce the sample size for confirmatory test.

  14. A comparative study of accelerated tests to simulate atmospheric corrosion

    International Nuclear Information System (INIS)

    Assis, Sergio Luiz de

    2000-01-01

    In this study, specimens coated with five organic coating systems were exposed to accelerated tests for periods up to 2000 hours, and also to weathering for two years and six months. The accelerated tests consisted of the salt spray test, according to ASTM B-117; Prohesion (ASTM G 85-98 annex 5A); Prohesion combined with cyclic exposure to UV-A radiation and condensation; 'Prohchuva' a test described by ASTM G 85-98 using a salt spray with composition that simulated the acid rain of Sao Paulo, but one thousand times more concentrated, and 'Prohchuva' combined with cyclic exposure to UV-A radiation and condensation. The coated specimens were exposed with and without incision to expose the substrate. The onset and progress of corrosion at and of the exposed metallic surface, besides coating degradation, were followed by visual observation, and photographs were taken. The coating systems were classified according to the extent of corrosion protection given to the substrate, using a method based on ASTM standards D-610, D-714, D-1654 and D-3359. The rankings of the coatings obtained from accelerated tests and weathering were compared and contrasted with classification of the same systems obtained from literature, for specimens exposed to an industrial atmosphere. Coating degradation was strongly dependent on the test, and could be attributed to differences in test conditions. The best correlation between accelerated test and weathering was found for the test Prohesion alternated with cycles of exposure to UV-A radiation and condensation. (author)

  15. Comparative evaluation of competitive ELISA test in Colombian cattle

    International Nuclear Information System (INIS)

    Marino, O.; Rueda, E.; Sedano, L.; Zuniga, I.; Calderon, C.; Ortega, A.; Puentes, A.

    1998-01-01

    In order to contribute to the definition of the best ELISA test for screening and differential diagnosis of Brucella abortus to be applied for control programmes, a total of 2971 sera from Colombian cattle were tested for brucellosis. Conventional agglutination tests, Buffered Plate antigen test (BPAT) and Rose Bengal (RB) as well as Complement Fixation test (CFT) (Alton, et al. 1988) were used comparatively. Radial immunodiffusion test (RID) was also performed to all sera. The sera were also tested using four different ELISAs: indirect ELISA from FAO/IAEA and the indirect ELISA modified by Nielsen, et al. 1992 as well as two competitive ELISAs: one competitive ELISA used B. abortus O-polysaccharide antigen and an enzyme conjugated monoclonal to the O-polysaccharide for competition and detection. The second competitive ELISA used lipopolysaccharide (sLPS) antigen, a different monoclonal antibody for competition but also specific for the O-polysaccharide and a commercially available goat anti-mouse IgG enzyme conjugate for detection. The sera were analyzed based on its population status, 987 positive obtained from Brucella abortus infected herds based on clinical and/or bacteriological evidence and a high prevalence of brucellosis, CFT percentage of positive animals in the herd was greater than 5%. Eight hundred sixty six (866) negative sera from non-vaccinated cattle from a brucellosis free area and 1118 negative sera obtained from reglamentary vaccinated areas under a free herd program. Initial cut-off values were derived using negative serum samples. The diagnostic sensitivity and specificity was defined from frequency histograms based on this cut-off values and using 2x2 tables, corresponding confidence limits (95%) were calculated. The data were also analysed using signal detection analysis (ROC). Kappa statistics was determined for all tests and populations, accuracy was used as index of comparison to evaluate different assays. The data support the initial

  16. Characteristics and international comparability of the Finnish matrix sentence test in cochlear implant recipients.

    Science.gov (United States)

    Dietz, Aarno; Buschermöhle, Michael; Sivonen, Ville; Willberg, Tytti; Aarnisalo, Antti A; Lenarz, Thomas; Kollmeier, Birger

    2015-01-01

    The first Finnish sentence-based speech test in noise--the Finnish matrix sentence test--was recently developed. The aim of this study was to determine the characteristics of the new test with respect to test-retest reliability, speech recognition curve, and international comparability in Finnish cochlear implant (CI) recipients. The speech reception thresholds (SRT) were measured by means of an adaptive test procedure and compared with the results of the traditional Finnish word test. Additional measurements for concurrent slope and SRT estimation were conducted to determine the speech recognition curve and to check the test-retest reliability. The measurements were performed on 78 Finnish CI recipients. In a subset of 25 patients, additional measurements for test-retest reliability and slope determination were performed. The mean SRT was -3.5 ± 1.7 dB SNR, with only a weak correlation with the Finnish word test. Test-retest reliability was within ± 1 dB and the mean slope of the speech recognition curve was 14.6 ± 3.6 %/dB. The rehabilitation results were similar to the results published for the German matrix test. The Finnish matrix test was found to be suitable and efficient in CI recipients with similar characteristics as the German matrix test.

  17. Comparative study of heuristic evaluation and usability testing methods.

    Science.gov (United States)

    Thyvalikakath, Thankam Paul; Monaco, Valerie; Thambuganipalle, Himabindu; Schleyer, Titus

    2009-01-01

    Usability methods, such as heuristic evaluation, cognitive walk-throughs and user testing, are increasingly used to evaluate and improve the design of clinical software applications. There is still some uncertainty, however, as to how those methods can be used to support the development process and evaluation in the most meaningful manner. In this study, we compared the results of a heuristic evaluation with those of formal user tests in order to determine which usability problems were detected by both methods. We conducted heuristic evaluation and usability testing on four major commercial dental computer-based patient records (CPRs), which together cover 80% of the market for chairside computer systems among general dentists. Both methods yielded strong evidence that the dental CPRs have significant usability problems. An average of 50% of empirically-determined usability problems were identified by the preceding heuristic evaluation. Some statements of heuristic violations were specific enough to precisely identify the actual usability problem that study participants encountered. Other violations were less specific, but still manifested themselves in usability problems and poor task outcomes. In this study, heuristic evaluation identified a significant portion of problems found during usability testing. While we make no assumptions about the generalizability of the results to other domains and software systems, heuristic evaluation may, under certain circumstances, be a useful tool to determine design problems early in the development cycle.

  18. A comparative study of three cytotoxicity test methods for nanomaterials using sodium lauryl sulfate.

    Science.gov (United States)

    Kwon, Jae-Sung; Kim, Kwang-Mahn; Kim, Kyoung-Nam

    2014-10-01

    The biocompatibility evaluation of nanomaterials is essential for their medical diagnostic and therapeutic usage, where a cytotoxicity test is the simplest form of biocompatibility evaluation. Three methods have been commonly used in previous studies for the cytotoxicity testing of nanomaterials: trypan blue exclusion, colorimetric assay using water soluble tetrazolium (WST), and imaging under a microscope following calcein AM/ethidium homodimer-1 staining. However, there has yet to be a study to compare each method. Therefore, in this study three methods were compared using the standard reference material of sodium lauryl sulfate (SLS). Each method of the cytotoxicity test was carried out using mouse fibroblasts of L-929 exposed to different concentrations of SLS. Compared to the gold standard trypan blue exclusion test, both colorimetric assay using water soluble tetrazolium (WST) and imaging under microscope with calcein AM/ethidium homodimer-1 staining showed results that were not statistically different. Also, each method exhibited various advantages and disadvantages, which included the need of equipment, time taken for the experiment, and provision of additional information such as cell morphology. Therefore, this study concludes that all three methods of cytotoxicity testing may be valid, though careful consideration will be needed when selecting tests with regard to time, finances, and the amount of information required by the researcher(s).

  19. On the comparability of acceptance tests for concrete by operation characteristics

    International Nuclear Information System (INIS)

    Rackwitz, R.

    1978-01-01

    The purely statistical aspect of acceptance tests can be estimated by means of operation characteristics, the position and steepness of which determine the probability for acceptance or rejection of offered loads. For negative decisions in concrete checking there will be, as a rule, an after-check in normal quality control. The operation characteristics with after-check valid for DIN 1045, DIN 1084, and DIN 1048 are set up. Complete comparability of different acceptance tests by means of the operation characteristic can only be achieved if the different sampling rates and the number of decisions are also included in the consideration. Proposals for improving the acceptance tests for concrete are presented. (orig.) [de

  20. Comparative Field Tests of Pressurised Rover Prototypes

    Science.gov (United States)

    Mann, G. A.; Wood, N. B.; Clarke, J. D.; Piechochinski, S.; Bamsey, M.; Laing, J. H.

    The conceptual designs, interior layouts and operational performances of three pressurised rover prototypes - Aonia, ARES and Everest - were field tested during a recent simulation at the Mars Desert Research Station in Utah. A human factors experiment, in which the same crew of three executed the same simulated science mission in each of the three vehicles, yielded comparative data on the capacity of each vehicle to safely and comfortably carry explorers away from the main base, enter and exit the vehicle in spacesuits, perform science tasks in the field, and manage geological and biological samples. As well as offering recommendations for design improvements for specific vehicles, the results suggest that a conventional Sports Utility Vehicle (SUV) would not be suitable for analog field work; that a pressurised docking tunnel to the main habitat is essential; that better provisions for spacesuit storage are required; and that a crew consisting of one driver/navigator and two field science crew specialists may be optimal. From a field operations viewpoint, a recurring conflict between rover and habitat crews at the time of return to the habitat was observed. An analysis of these incidents leads to proposed refinements of operational protocols, specific crew training for rover returns and again points to the need for a pressurised docking tunnel. Sound field testing, circulating of results, and building the lessons learned into new vehicles is advocated as a way of producing ever higher fidelity rover analogues.

  1. Comparative Testing for Corporate Impact Assessment Tools

    DEFF Research Database (Denmark)

    Farsang, Andrea; Reisch, Lucia A.

    of our study are: poverty, water and sanitation, education, food and agriculture, climate change, and human rights in three industries, namely: footwear, coffee, and paper and pulp. The paper develops a protocol for the selection and quantification of indicators that can be used in selecting...... the appropriate tools for measuring impacts in the selected sectors on SDGs. Background: In the Global Value Project, a long list of indicators was compiled covering the main thematic areas and challenges of sustainability. In a second step, this long list was reduced using predefined criteria as well as other...... criteria, such as the feasibility and scalability of different tools. As a result, a protocol was developed to help compare the different tools that measure corporate impact and to interpret the results in relation to the SDGs. The protocol was pre-tested with a limited number of tools in two case studies...

  2. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    Science.gov (United States)

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  3. The insulation structure of the 1 MV transmission line for the ITER neutral beam injector

    International Nuclear Information System (INIS)

    De Lorenzi, A.; Grando, L.; Gobbo, R.; Pesavento, G.; Bettini, P.; Specogna, R.; Trevisan, F.

    2007-01-01

    The paper describes the studies and the tests for the development of the insulation structure of the 1 MV-50 A gas insulated (SF 6 ) line of the ITER NBI in the SinGap configuration characterized by two kinds of spacers: at least a couple of disk-shaped spacers, designed to be gas tight, and a larger number (several tens) of inner conductor post spacers. To this aim a test campaign has been carried out to assess the capability of standard epoxy spacers to withstand a high dc voltage with frequent short circuits, simulating the operational condition for the ITER NBI. Two computational tools, the first for the epoxy spacer shape optimization under electrostatic distribution and the other for the nonlinear time variant evolution of the electric field and surface charge, have been developed specifically for designing epoxy spacer under dc voltage stress. The results on the optimization of the disk spacer and on the electric field-surface charge time evolution of the post spacer are reported and discussed. The effects of the SF 6 radiation induced conductivity on the post spacer are also reported

  4. The insulation structure of the 1 MV transmission line for the ITER neutral beam injector

    Energy Technology Data Exchange (ETDEWEB)

    De Lorenzi, A. [Consorzio RFX, Associazione Euratom-Enea sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy)], E-mail: antonio.delorenzi@igi.cnr.it; Grando, L. [Consorzio RFX, Associazione Euratom-Enea sulla Fusione, Corso Stati Uniti 4, I-35127 Padova (Italy); Gobbo, R.; Pesavento, G. [DIE, Universita di Padova, Via Gradenigo 6A, I-35100 Padova (Italy); Bettini, P.; Specogna, R.; Trevisan, F. [DIEGM, Universita di Udine, Via delle Scienze 208, I-33100 Udine (Italy)

    2007-10-15

    The paper describes the studies and the tests for the development of the insulation structure of the 1 MV-50 A gas insulated (SF{sub 6}) line of the ITER NBI in the SinGap configuration characterized by two kinds of spacers: at least a couple of disk-shaped spacers, designed to be gas tight, and a larger number (several tens) of inner conductor post spacers. To this aim a test campaign has been carried out to assess the capability of standard epoxy spacers to withstand a high dc voltage with frequent short circuits, simulating the operational condition for the ITER NBI. Two computational tools, the first for the epoxy spacer shape optimization under electrostatic distribution and the other for the nonlinear time variant evolution of the electric field and surface charge, have been developed specifically for designing epoxy spacer under dc voltage stress. The results on the optimization of the disk spacer and on the electric field-surface charge time evolution of the post spacer are reported and discussed. The effects of the SF{sub 6} radiation induced conductivity on the post spacer are also reported.

  5. Test person operated 2-Alternative Forced Choice Audiometry compared to traditional audiometry

    DEFF Research Database (Denmark)

    Schmidt, Jesper Hvass; Brandt, Christian; Christensen-Dalsgaard, Jakob

      Background: With a newly developed technique, hearing thresholds can be estimated with a system operated by the test persons themselves. This technique is based on the 2 Alternative Forced Choice paradigm known from the psychoacoustic research theory. Test persons can operate the system very......-likelihood and up-down methods has proven effective and reliable even under suboptimal test settings. In non-optimal testing conditions i.e. as a part of a hearing conservation programme the headphone Sennheiser HDA-200 has been used as it contains hearing protection. This test-method has been validated......-retest studies of 2AFC audiometry are comparable to test-retest results known from traditional audiometry under standard clinical settings.   Conclusions 2 Alternative Forced Choice audiometry can be a reliable alternative to traditional audiometry especially under certain circumstances, where it can...

  6. PISA - An Example of the Use and Misuse of Large-Scale Comparative Tests

    DEFF Research Database (Denmark)

    Dolin, Jens

    2007-01-01

    The article will analyse PISA - particularly the part dealing with science - as an example of a major comparative evaluation. PISA will first be described and then analysed on the basis of test theory, which will address some detailed technical aspects of the test as well as the broader issue...

  7. Comparing Global Initiative for Asthma (GINA) criteria with the Childhood Asthma Control Test (C-ACT) and Asthma Control Test (ACT)

    NARCIS (Netherlands)

    Koolen, B.B.; Pijnenburg, M.W.; Brackel, H.J.; Landstra, A.M.; Berg, N.J. van den; Merkus, P.J.F.M.; Hop, W.C.J.; Vaessen-Verberne, A.A.

    2011-01-01

    Several tools are useful in detecting uncontrolled asthma in children. The aim of this study was to compare Global Initiative for Asthma (GINA) guidelines with the Childhood Asthma Control Test (C-ACT) and the Asthma Control Test (ACT) in detecting uncontrolled asthma in children. 145 children with

  8. Power of tests for comparing trend curves with application to national immunization survey (NIS).

    Science.gov (United States)

    Zhao, Zhen

    2011-02-28

    To develop statistical tests for comparing trend curves of study outcomes between two socio-demographic strata across consecutive time points, and compare statistical power of the proposed tests under different trend curves data, three statistical tests were proposed. For large sample size with independent normal assumption among strata and across consecutive time points, the Z and Chi-square test statistics were developed, which are functions of outcome estimates and the standard errors at each of the study time points for the two strata. For small sample size with independent normal assumption, the F-test statistic was generated, which is a function of sample size of the two strata and estimated parameters across study period. If two trend curves are approximately parallel, the power of Z-test is consistently higher than that of both Chi-square and F-test. If two trend curves cross at low interaction, the power of Z-test is higher than or equal to the power of both Chi-square and F-test; however, at high interaction, the powers of Chi-square and F-test are higher than that of Z-test. The measurement of interaction of two trend curves was defined. These tests were applied to the comparison of trend curves of vaccination coverage estimates of standard vaccine series with National Immunization Survey (NIS) 2000-2007 data. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Compensation of kinematic geometric parameters error and comparative study of accuracy testing for robot

    Science.gov (United States)

    Du, Liang; Shi, Guangming; Guan, Weibin; Zhong, Yuansheng; Li, Jin

    2014-12-01

    Geometric error is the main error of the industrial robot, and it plays a more significantly important fact than other error facts for robot. The compensation model of kinematic error is proposed in this article. Many methods can be used to test the robot accuracy, therefore, how to compare which method is better one. In this article, a method is used to compare two methods for robot accuracy testing. It used Laser Tracker System (LTS) and Three Coordinate Measuring instrument (TCM) to test the robot accuracy according to standard. According to the compensation result, it gets the better method which can improve the robot accuracy apparently.

  10. The microdose rapid 14C urea breath test compares well with the original rapid 14 breath test

    International Nuclear Information System (INIS)

    Bellon, M.S.; Bartholomeusz, F.D.L.; Chatterton, B.E.

    2000-01-01

    Full text: The 14 C urea breath test (CUBT) is a sensitive test used in the detection of H. pylori infection. The rapid 14 CUBT using 185 KBq of 14 C urea showed a sensitivity of 100% when tested in 36 patients. The aim of this study was to compare the results of the 14 CUBT performed following the ingestion of 37KBq microdose 14 C urea capsule (Bicapsule, Trimed) with the earlier method which uses 185 KBq 14 C urea. 19 patients (nine female age 21-52 yrs) were studied. All subjects first underwent a 14 CUBT with the microdose capsule and a single 15 minute post ingestion sample. An hour later the test was repeated but with a dose of 185 KBq 14 C urea in liquid form. A normal result was taken as 2 = 0.92). This is shown above. The Rapid 14 CUBT performed following the microdose capsule whilst reducing patient radiation exposure is an accurate test for the detection of H. pylori. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  11. A Comparative Analysis of Two Full-Scale MD-500 Helicopter Crash Tests

    Science.gov (United States)

    Littell, Justin D.

    2011-01-01

    Two full scale crash tests were conducted on a small MD-500 helicopter at NASA Langley Research Center fs Landing and Impact Research Facility. One of the objectives of this test series was to compare airframe impact response and occupant injury data between a test which outfitted the airframe with an external composite passive energy absorbing honeycomb and a test which had no energy absorbing features. In both tests, the nominal impact velocity conditions were 7.92 m/sec (26 ft/sec) vertical and 12.2 m/sec (40 ft/sec) horizontal, and the test article weighed approximately 1315 kg (2900 lbs). Airframe instrumentation included accelerometers and strain gages. Four Anthropomorphic Test Devices were also onboard; three of which were standard Hybrid II and III, while the fourth was a specialized torso. The test which contained the energy absorbing honeycomb showed vertical impact acceleration loads of approximately 15 g, low risk for occupant injury probability, and minimal airframe damage. These results were contrasted with the test conducted without the energy absorbing honeycomb. The test results showed airframe accelerations of approximately 40 g in the vertical direction, high risk for injury probability in the occupants, and substantial airframe damage.

  12. Monte Carlo Simulations Comparing Fisher Exact Test and Unequal Variances t Test for Analysis of Differences Between Groups in Brief Hospital Lengths of Stay.

    Science.gov (United States)

    Dexter, Franklin; Bayman, Emine O; Dexter, Elisabeth U

    2017-12-01

    We examined type I and II error rates for analysis of (1) mean hospital length of stay (LOS) versus (2) percentage of hospital LOS that are overnight. These 2 end points are suitable for when LOS is treated as a secondary economic end point. We repeatedly resampled LOS for 5052 discharges of thoracoscopic wedge resections and lung lobectomy at 26 hospitals. Unequal variances t test (Welch method) and Fisher exact test both were conservative (ie, type I error rate less than nominal level). The Wilcoxon rank sum test was included as a comparator; the type I error rates did not differ from the nominal level of 0.05 or 0.01. Fisher exact test was more powerful than the unequal variances t test at detecting differences among hospitals; estimated odds ratio for obtaining P < .05 with Fisher exact test versus unequal variances t test = 1.94, with 95% confidence interval, 1.31-3.01. Fisher exact test and Wilcoxon-Mann-Whitney had comparable statistical power in terms of differentiating LOS between hospitals. For studies with LOS to be used as a secondary end point of economic interest, there is currently considerable interest in the planned analysis being for the percentage of patients suitable for ambulatory surgery (ie, hospital LOS equals 0 or 1 midnight). Our results show that there need not be a loss of statistical power when groups are compared using this binary end point, as compared with either Welch method or Wilcoxon rank sum test.

  13. Design-related bias in estimates of accuracy when comparing imaging tests: examples from breast imaging research

    International Nuclear Information System (INIS)

    Houssami, Nehmat; Ciatto, Stefano

    2010-01-01

    This work highlights concepts on the potential for design-related factors to bias estimates of test accuracy in comparative imaging research. We chose two design factors, selection of eligible subjects and the reference standard, to examine the effect of design limitations on estimates of accuracy. Estimates of sensitivity in a study of the comparative accuracy of mammography and ultrasound differed according to how subjects were selected. Comparison of a new imaging test with an existing test should distinguish whether the new test is to be used as a replacement for, or as an adjunct to, the conventional test, to guide the method for subject selection. Quality of the reference standard, examined in a meta-analysis of preoperative breast MRI, varied across studies and was associated with estimates of incremental accuracy. Potential solutions to deal with the reference standard are outlined where an ideal reference standard may not be available in all subjects. These examples of breast imaging research demonstrate that design-related bias, when comparing a new imaging test with a conventional imaging test, may bias accuracy in a direction that favours the new test by overestimating the accuracy of the new test or by underestimating that of the conventional test. (orig.)

  14. Comparative Analyses of Zebrafish Anxiety-Like Behavior Using Conflict-Based Novelty Tests.

    Science.gov (United States)

    Kysil, Elana V; Meshalkina, Darya A; Frick, Erin E; Echevarria, David J; Rosemberg, Denis B; Maximino, Caio; Lima, Monica Gomes; Abreu, Murilo S; Giacomini, Ana C; Barcellos, Leonardo J G; Song, Cai; Kalueff, Allan V

    2017-06-01

    Modeling of stress and anxiety in adult zebrafish (Danio rerio) is increasingly utilized in neuroscience research and central nervous system (CNS) drug discovery. Representing the most commonly used zebrafish anxiety models, the novel tank test (NTT) focuses on zebrafish diving in response to potentially threatening stimuli, whereas the light-dark test (LDT) is based on fish scototaxis (innate preference for dark vs. bright areas). Here, we systematically evaluate the utility of these two tests, combining meta-analyses of published literature with comparative in vivo behavioral and whole-body endocrine (cortisol) testing. Overall, the NTT and LDT behaviors demonstrate a generally good cross-test correlation in vivo, whereas meta-analyses of published literature show that both tests have similar sensitivity to zebrafish anxiety-like states. Finally, NTT evokes higher levels of cortisol, likely representing a more stressful procedure than LDT. Collectively, our study reappraises NTT and LDT for studying anxiety-like states in zebrafish, and emphasizes their developing utility for neurobehavioral research. These findings can help optimize drug screening procedures by choosing more appropriate models for testing anxiolytic or anxiogenic drugs.

  15. Comparing fire spread algorithms using equivalence testing and neutral landscape models

    Science.gov (United States)

    Brian R. Miranda; Brian R. Sturtevant; Jian Yang; Eric J. Gustafson

    2009-01-01

    We demonstrate a method to evaluate the degree to which a meta-model approximates spatial disturbance processes represented by a more detailed model across a range of landscape conditions, using neutral landscapes and equivalence testing. We illustrate this approach by comparing burn patterns produced by a relatively simple fire spread algorithm with those generated by...

  16. A multivariate rank test for comparing mass size distributions

    KAUST Repository

    Lombard, F.

    2012-04-01

    Particle size analyses of a raw material are commonplace in the mineral processing industry. Knowledge of particle size distributions is crucial in planning milling operations to enable an optimum degree of liberation of valuable mineral phases, to minimize plant losses due to an excess of oversize or undersize material or to attain a size distribution that fits a contractual specification. The problem addressed in the present paper is how to test the equality of two or more underlying size distributions. A distinguishing feature of these size distributions is that they are not based on counts of individual particles. Rather, they are mass size distributions giving the fractions of the total mass of a sampled material lying in each of a number of size intervals. As such, the data are compositional in nature, using the terminology of Aitchison [1] that is, multivariate vectors the components of which add to 100%. In the literature, various versions of Hotelling\\'s T 2 have been used to compare matched pairs of such compositional data. In this paper, we propose a robust test procedure based on ranks as a competitor to Hotelling\\'s T 2. In contrast to the latter statistic, the power of the rank test is not unduly affected by the presence of outliers or of zeros among the data. © 2012 Copyright Taylor and Francis Group, LLC.

  17. Compare diagnostic tests using transformation-invariant smoothed ROC curves⋆

    Science.gov (United States)

    Tang, Liansheng; Du, Pang; Wu, Chengqing

    2012-01-01

    Receiver operating characteristic (ROC) curve, plotting true positive rates against false positive rates as threshold varies, is an important tool for evaluating biomarkers in diagnostic medicine studies. By definition, ROC curve is monotone increasing from 0 to 1 and is invariant to any monotone transformation of test results. And it is often a curve with certain level of smoothness when test results from the diseased and non-diseased subjects follow continuous distributions. Most existing ROC curve estimation methods do not guarantee all of these properties. One of the exceptions is Du and Tang (2009) which applies certain monotone spline regression procedure to empirical ROC estimates. However, their method does not consider the inherent correlations between empirical ROC estimates. This makes the derivation of the asymptotic properties very difficult. In this paper we propose a penalized weighted least square estimation method, which incorporates the covariance between empirical ROC estimates as a weight matrix. The resulting estimator satisfies all the aforementioned properties, and we show that it is also consistent. Then a resampling approach is used to extend our method for comparisons of two or more diagnostic tests. Our simulations show a significantly improved performance over the existing method, especially for steep ROC curves. We then apply the proposed method to a cancer diagnostic study that compares several newly developed diagnostic biomarkers to a traditional one. PMID:22639484

  18. VALIDITY IN COMPUTER-BASED TESTING: A LITERATURE REVIEW OF COMPARABILITY ISSUES AND EXAMINEE PERSPECTIVES

    Directory of Open Access Journals (Sweden)

    Ika Kana Trisnawati

    2015-05-01

    Full Text Available These past years have seen the growing popularity of the Computer-Based Tests (CBTs in various disciplines, for various purposes, although the Paper-and Pencil Based Tests (P&Ps are still in use. However, many question on whether the use of CBTs outperform the effectiveness of the P&Ps or if the CBTs can become a valid measuring tool compared to the PBTs. This paper tries to present the comparison on both the CBTs and the P&Ps and their respective examinee perspectives in order to figure out if doubts should arise to the emergence of the CBTs over the classic P&Ps. Findings showed that the CBTs are advantageous in that they are both efficient (reducing testing time and effective (maintaining the test reliability over the P&P versions. Nevertheless, the CBTs still need to have their variables well-designed (e.g., study design, computer algorithm in order for the scores to be comparable to those in the P&P tests since the score equivalence is one of the validity evidences needed in a CBT.

  19. In-pile data analysis of the comparative WWER/PWR test IFA-503.1. Final report.

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, B.; Devold, H.; Ryazantzev, E.; Yakovlev, V.

    1999-04-15

    The comparative WWER/PWR test in IFA-503.1 was commenced in July 1995 and successfully finished at the end of November 1998. The main objective of the test was generation of representative and comparative data of standard WWER-440 fuel fabricated at the 'MSZ' Electrostal (Russia) and PWR type fuel manufactured at IFE Kjeller (Norway). The test assembly comprised two clusters, each with 3 WWER rods and 3 PWR type rods. Eight rods with two types of fuel were instrumented with expansion thermometers, four rods were equipped with both fuel stack elongation detectors and pressure transducers. All sensors worked satisfactorily during the test. The average burnups achieved in the lower and upper clusters were around 25 and 20 MWd/kgUO{sub 2}, respectively. Some difference in densification of the two types of fuel was revealed during the first irradiation period. However, the fuel temperatures and commencement of fuel stack swelling were similar despite this fact. At the end of the test the rig was moved to a higher flux position in the HBWR core with the aim of promoting FGR and to compare the behaviour of the two types of fuel under higher power. Pressure measurements indicated a comparable low FGR (around 1 percent) in both types of rods. The centreline temperatures measured in the PWR rods were very close to the Halden FGR threshold whilst the WWER fuel temperatures were slightly lower. Despite the differences found in the behaviour of the two types of fuel during the test, the analysis of the in-pile data showed that these differences would not affect the fuel efficiency, at least, up to the burnup achieved in the test. It is supposed that these differences can be related to the fuel microstructure, in particular to the fuel grain and pore sizes (author) (ml)

  20. In-pile data analysis of the comparative WWER/PWR test IFA-503.1. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, B.; Devold, H.; Ryazantzev, E.; Yakovlev, V

    1999-04-15

    The comparative WWER/PWR test in IFA-503.1 was commenced in July 1995 and successfully finished at the end of November 1998. The main objective of the test was generation of representative and comparative data of standard WWER-440 fuel fabricated at the 'MSZ' Electrostal (Russia) and PWR type fuel manufactured at IFE Kjeller (Norway). The test assembly comprised two clusters, each with 3 WWER rods and 3 PWR type rods. Eight rods with two types of fuel were instrumented with expansion thermometers, four rods were equipped with both fuel stack elongation detectors and pressure transducers. All sensors worked satisfactorily during the test. The average burnups achieved in the lower and upper clusters were around 25 and 20 MWd/kgUO{sub 2}, respectively. Some difference in densification of the two types of fuel was revealed during the first irradiation period. However, the fuel temperatures and commencement of fuel stack swelling were similar despite this fact. At the end of the test the rig was moved to a higher flux position in the HBWR core with the aim of promoting FGR and to compare the behaviour of the two types of fuel under higher power. Pressure measurements indicated a comparable low FGR (around 1 percent) in both types of rods. The centreline temperatures measured in the PWR rods were very close to the Halden FGR threshold whilst the WWER fuel temperatures were slightly lower. Despite the differences found in the behaviour of the two types of fuel during the test, the analysis of the in-pile data showed that these differences would not affect the fuel efficiency, at least, up to the burnup achieved in the test. It is supposed that these differences can be related to the fuel microstructure, in particular to the fuel grain and pore sizes (author) (ml)

  1. Old world monkeys compare to apes in the primate cognition test battery.

    Directory of Open Access Journals (Sweden)

    Vanessa Schmitt

    Full Text Available Understanding the evolution of intelligence rests on comparative analyses of brain sizes as well as the assessment of cognitive skills of different species in relation to potential selective pressures such as environmental conditions and social organization. Because of the strong interest in human cognition, much previous work has focused on the comparison of the cognitive skills of human toddlers to those of our closest living relatives, i.e. apes. Such analyses revealed that apes and children have relatively similar competencies in the physical domain, while human children excel in the socio-cognitive domain; in particular in terms of attention sharing, cooperation, and mental state attribution. To develop a full understanding of the evolutionary dynamics of primate intelligence, however, comparative data for monkeys are needed. We tested 18 Old World monkeys (long-tailed macaques and olive baboons in the so-called Primate Cognition Test Battery (PCTB (Herrmann et al. 2007, Science. Surprisingly, our tests revealed largely comparable results between Old World monkeys and the Great apes. Single comparisons showed that chimpanzees performed only better than the macaques in experiments on spatial understanding and tool use, but in none of the socio-cognitive tasks. These results question the clear-cut relationship between cognitive performance and brain size and--prima facie--support the view of an accelerated evolution of social intelligence in humans. One limitation, however, is that the initial experiments were devised to tap into human specific skills in the first place, thus potentially underestimating both true nonhuman primate competencies as well as species differences.

  2. Comparative Evaluation of Seven Commercial Tests for Detection of Heterophile Antibody in Infectious Mononucleosis

    Directory of Open Access Journals (Sweden)

    Martin Skulnick

    1992-01-01

    Full Text Available Detection of heterophile antibodies in infectious mononucleosis is the most rapid and cost-effective method for confirming the clinical diagnosis of the disease. This study compared seven commercial test kits (the Oxoid Infectious Mononucleosis Kit [Oxoid Ltd], Immunoscan Im-Latex [Baxter Travenol], Mono-Latex [Wampole Laboratories], Monospot and Im Screen Test [Ortho Diagnostics], Immunoscan Im-RBC Test [Baxter Travenol], and Infectious Mononucleosis Test [NCS Diagnostics] to the Davidsohn differential test. All of the kits were shown to be acceptable for use, with specificities and sensitivities greater than 96.5% and 95.5%, respectively.

  3. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  4. Accelerated Comparative Fatigue Strength Testing of Belt Adhesive Joints

    Science.gov (United States)

    Bajda, Miroslaw; Blazej, Ryszard; Jurdziak, Leszek

    2017-12-01

    Belt joints are the weakest link in the serial structure that creates an endless loop of spliced belt segments. This affects not only the lower strength of adhesive joints of textile belts in comparison to vulcanized splices, but also the replacement of traditional glues to more ecological but with other strength parameters. This is reflected in the lowered durability of adhesive joints, which in underground coal mines is nearly twice shorter than the operating time of belts. Vulcanized splices require high precision in performance, they need long time to achieve cross-linking of the friction mixture and, above all, they require specialized equipment (vulcanization press) which is not readily available and often takes much time to be delivered down, which means reduced mining output or even downtime. All this reduces the reliability and durability of adhesive joints. In addition, due to the consolidation on the Polish coal market, mines are joined into large economic units serviced by a smaller number of processing plants. The consequence is to extend the transport routes downstream and increase reliability requirements. The greater number of conveyors in the chain reduces reliability of supply and increases production losses. With high fixed costs of underground mines, the reduction in mining output is reflected in the increase in unit costs, and this at low coal prices on the market can mean substantial losses for mines. The paper describes the comparative study of fatigue strength of shortened samples of adhesive joints conducted to compare many different variants of joints (various adhesives and materials). Shortened samples were exposed to accelerated fatigue in the usually long-lasting dynamic studies, allowing more variants to be tested at the same time. High correlation between the results obtained for shortened (100 mm) and traditional full-length (3×250 mm) samples renders accelerated tests possible.

  5. Comparing of four IRT models when analyzing two tests for inductive reasoning

    NARCIS (Netherlands)

    de Koning, E.; Sijtsma, K.; Hamers, J.H.M.

    2002-01-01

    This article discusses the use of the nonparametric IRT Mokken models of monotone homogeneity and double monotonicity and the parametric Rasch and Verhelst models for the analysis of binary test data. First, the four IRT models are discussed and compared at the theoretical level, and for each model,

  6. A Note on Comparing the Power of Test Statistics at Low Significance Levels.

    Science.gov (United States)

    Morris, Nathan; Elston, Robert

    2011-01-01

    It is an obvious fact that the power of a test statistic is dependent upon the significance (alpha) level at which the test is performed. It is perhaps a less obvious fact that the relative performance of two statistics in terms of power is also a function of the alpha level. Through numerous personal discussions, we have noted that even some competent statisticians have the mistaken intuition that relative power comparisons at traditional levels such as α = 0.05 will be roughly similar to relative power comparisons at very low levels, such as the level α = 5 × 10 -8 , which is commonly used in genome-wide association studies. In this brief note, we demonstrate that this notion is in fact quite wrong, especially with respect to comparing tests with differing degrees of freedom. In fact, at very low alpha levels the cost of additional degrees of freedom is often comparatively low. Thus we recommend that statisticians exercise caution when interpreting the results of power comparison studies which use alpha levels that will not be used in practice.

  7. Agreement analysis comparing iPad LCVA and Sloan testing in multiple sclerosis patients.

    Science.gov (United States)

    Sattarnezhad, Neda; Farrow, Samantha; Kimbrough, Dorlan; Glanz, Bonnie; Healy, Brian; Chitnis, Tanuja

    2017-06-01

    Visual symptoms are common in multiple sclerosis (MS). Low-contrast visual acuity (LCVA) testing using Sloan charts has demonstrated increased sensitivity for visual deficits compared to high-contrast acuity testing. Computerized testing of visual acuity may facilitate use in the clinic setting. To evaluate the agreement between an iPad-based and Sloan testing of LCVA in a cohort of MS patients. A total of 38 patients with relapsing-remitting MS were enrolled after providing informed written consent at Partners MS Center, Brigham and Women's hospital. Monocular LCVA was measured using retroilluminated Sloan chart and iPad-based LogMAR chart. Number of correct letters and agreement between two measurements were assessed for each eye using Bland-Altman analysis and paired t-test. For both eyes, there was no significant difference in number correct between the two measurements using a paired t-test, and there was high correlation between two measurements (oculus dextrus (OD) r = 0.89, p iPad-based LCVA test shows good agreement with Sloan testing in MS patients.

  8. Accuracy and reliability of Tzanck test compared to histopathology for diagnosis of basal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Vivek Kumar Dey

    2015-01-01

    Full Text Available Background: Histopathology is considered the gold standard for diagnosis of basal cell carcinoma (BCC but is time consuming and needs expertise to make a correct diagnosis. On the other hand, Tzanck test is a simple, easy, inexpensive and rapid test which uses exfoliative cytology to make a diagnosis. Objective: To compare the results of Tzanck test with histopathology in the diagnosis of BCC and to evaluate the diagnostic reliability and accuracy of Tzanck test in BCC. Materials and Method: Twenty-six patients with clinical suspicion of BCC were recruited. Samples for Tzanck test and histopathology were taken and diagnoses made independently. Results of Tzanck test were compared with histopathology. Results: Twenty-three cases were histopathologically proved to be BCC. Tzanck test correlated in 12 cases of BCC and could exclude all three non-BCC lesions. In 11 cases it failed to diagnose BCC. The sensitivity and specificity of Tzanck test were 52.2% and 100%, respectively, and positive and negative predictive values were 100% and 21.4%. Conclusion: Tzanck test can be recommended for initial, rapid evaluation of a clinically diagnosed case of BCC. Under experienced hands, it reliably confirms BCC. The limitation is low negative predictive value. Since it does not give information about subtypes of BCC which is of great value in therapeutic planning, histopathological confirmation is mandatory.

  9. Comparative evaluation of Amplicor HIV-1 DNA test, version 1.5, by ...

    African Journals Online (AJOL)

    Human immunodeficiency virus (HIV) DNA polymerase chain reaction (PCR) test using venous blood sample has been used for many years in low resource settings for early infant diagnosis of HIV infection in children less than 18 months. The aim of this study was to evaluate and compare the performance characteristics of ...

  10. Clinical diagnosis of Graves’ or non-Graves’ hyperthyroidism compared to TSH receptor antibody test

    Directory of Open Access Journals (Sweden)

    Lauren Bell

    2018-04-01

    Full Text Available Background: TSH receptor antibody (TRAb is considered the gold standard diagnostic test for the autoimmunity of Graves’ disease (GD, which is commonly diagnosed clinically. Aim: To evaluate the true positive (sensitivity and true negative (specificity rates of clinical diagnosis of GD or non-GD hyperthyroidism compared to the TRAb test. Setting: University teaching hospital in North West England. Participants: Patients in the Endocrinology service who had a TRAb measurement between December 2009 and October 2015. Methods: Electronic patient records were studied retrospectively for a pre-TRAb clinical diagnosis of GD or non-GD hyperthyroidism. We examined descriptive statistics and binary classification tests; Fisher exact test was used to analyse contingency tables. Results: We identified 316 patients with a mean age of 45 (range, 17–89 years; 247 (78% were women. Compared to the TRAb result, clinical diagnosis had a sensitivity of 88%, specificity 66%, positive predictive value 72%, negative predictive value 84%, false negative rate 12%, false positive rate 34%, positive likelihood ratio 2.6 and negative likelihood ratio 0.2 (P < 0.0001. Conclusions: Clinicians were liable to both over- and under-diagnose GD. The TRAb test can help reduce the number of incorrect or unknown diagnoses in the initial clinical assessment of patients presenting with hyperthyroidism.

  11. Comparative testing of six antigen-based malaria vaccine candidates directed toward merozoite-stage Plasmodium falciparum

    DEFF Research Database (Denmark)

    Arnot, David E; Cavanagh, David R; Remarque, Edmond J

    2008-01-01

    Immunogenicity testing of Plasmodium falciparum antigens being considered as malaria vaccine candidates was undertaken in rabbits. The antigens compared were recombinant baculovirus MSP-1(19) and five Pichia pastoris candidates, including two versions of MSP-1(19), AMA-1 (domains I and II), AMA-1......G concentrations. The two P. pastoris-produced MSP-1(19)-induced IgGs conferred the lowest growth inhibition. Comparative analysis of immunogenicity of vaccine antigens can be used to prioritize candidates before moving to expensive GMP production and clinical testing. The assays used have given discriminating...

  12. A permutation testing framework to compare groups of brain networks.

    Science.gov (United States)

    Simpson, Sean L; Lyday, Robert G; Hayasaka, Satoru; Marsh, Anthony P; Laurienti, Paul J

    2013-01-01

    Brain network analyses have moved to the forefront of neuroimaging research over the last decade. However, methods for statistically comparing groups of networks have lagged behind. These comparisons have great appeal for researchers interested in gaining further insight into complex brain function and how it changes across different mental states and disease conditions. Current comparison approaches generally either rely on a summary metric or on mass-univariate nodal or edge-based comparisons that ignore the inherent topological properties of the network, yielding little power and failing to make network level comparisons. Gleaning deeper insights into normal and abnormal changes in complex brain function demands methods that take advantage of the wealth of data present in an entire brain network. Here we propose a permutation testing framework that allows comparing groups of networks while incorporating topological features inherent in each individual network. We validate our approach using simulated data with known group differences. We then apply the method to functional brain networks derived from fMRI data.

  13. Algal tests with soil suspensions and elutriates: A comparative evaluation for PAH contaminated soils

    DEFF Research Database (Denmark)

    Baun, Anders; Justesen, Kasper Bo; Nyholm, Niels

    2002-01-01

    An algal growth inhibition test procedure with soil suspensions is proposed and evaluated for PAH-contaminated soil. The growth rate reduction of the standard freshwater green alga Pseudokirchneriella subcapitata (formerly known as Selenastrum capricornutum) was used as the toxicity endpoint......, and was quantified by measuring the fluorescence of solvent-extracted algal pigments. No growth rate reduction was detected for soil contents up to 20 g/l testing five non-contaminated Danish soils. Comparative testing with PAH-contaminated soil elutriates and soil suspensions showed that the suspensions had...

  14. Corrosion of metals in wood : comparing the results of a rapid test method with long-term exposure tests across six wood treatments

    Science.gov (United States)

    Samuel L. Zelinka; Donald S. Stone

    2011-01-01

    This paper compares two methods of measuring the corrosion of steel and galvanized steel in wood: a long-term exposure test in solid wood and a rapid test method where fasteners are electrochemically polarized in extracts of wood treated with six different treatments. For traditional wood preservatives, the electrochemical extract method correlates with solid wood...

  15. Comparing and characterizing transient and steady-state tests of the peripheral chemoreflex in humans.

    Science.gov (United States)

    Pfoh, Jamie R; Tymko, Michael M; Abrosimova, Maria; Boulet, Lindsey M; Foster, Glen E; Bain, Anthony R; Ainslie, Philip N; Steinback, Craig D; Bruce, Christina D; Day, Trevor A

    2016-03-01

    What is the central question of this study? We aimed to characterize the cardiorespiratory and cerebrovascular responses to transient and steady-state tests of the peripheral chemoreflex and to compare the hypoxic ventilatory responses (HVRs) between these tests. What is the main finding and its importance? The cardiovascular and cerebrovascular responses to transient tests were small in magnitude and short in duration. The steady-state isocapnic hypoxia test elicited a larger HVR than the transient 100% N(2) test, but the response magnitudes were correlated within individuals. The transient test of the HVR elicits fewer systemic effects than steady-state techniques and may have greater experimental utility than previously appreciated. Carotid chemoreceptors detect changes in arterial PO(2) and PCO(2), eliciting a peripheral chemoreflex (PCR). Steady-state (SS) hypoxia tests using dynamic end-tidal forcing (DEF) have been used to assess the hypoxic ventilatory response (HVR) but may be confounded by concomitant systemic effects. Transient tests of the PCR have also been developed but are not widely used, nor have the cardiovascular and cerebrovascular responses been characterized. We characterized the cardiorespiratory and cerebrovascular responses to transient tests of the PCR and compared the HVR between transient and SS-DEF tests. We hypothesized that the cardiovascular and cerebrovascular responses to the transient tests would be minimal and that the respiratory responses elicited from the transient and SS-DEF tests would be different in magnitude and not well correlated within individuals. Participants underwent five consecutive trials of two transient tests [three-breath 100% N(2) (TT-N(2)) and a single-breath 13% CO(2), in air] and two 10 min SS-DEF tests [isocapnic (SS-ISO) and poikilocapnic (SS-POI) hypoxia]. In response to the transient tests, heart rate, mean arterial pressure and the middle and posterior cerebral artery blood velocity increased (all P

  16. Associations between mode of HIV testing and consent, confidentiality, and referral: a comparative analysis in four African countries.

    Directory of Open Access Journals (Sweden)

    Carla Makhlouf Obermeyer

    Full Text Available Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT or provider-initiated testing.The MATCH (Multi-Country African Testing and Counseling for HIV study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001, but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001 and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015. Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among

  17. Associations between mode of HIV testing and consent, confidentiality, and referral: a comparative analysis in four African countries.

    Science.gov (United States)

    Obermeyer, Carla Makhlouf; Neuman, Melissa; Desclaux, Alice; Wanyenze, Rhoda; Ky-Zerbo, Odette; Cherutich, Peter; Namakhoma, Ireen; Hardon, Anita

    2012-01-01

    Recommendations about scaling up HIV testing and counseling highlight the need to provide key services and to protect clients' rights, but it is unclear to what extent different modes of testing differ in this respect. This paper examines whether practices regarding consent, confidentiality, and referral vary depending on whether testing is provided through voluntary counseling and testing (VCT) or provider-initiated testing. The MATCH (Multi-Country African Testing and Counseling for HIV) study was carried out in Burkina Faso, Kenya, Malawi, and Uganda. Surveys were conducted at selected facilities. We defined eight outcome measures related to pre- and post-test counseling, consent, confidentiality, satisfactory interactions with providers, and (for HIV-positive respondents) referral for care. These were compared across three types of facilities: integrated facilities, where testing is provided along with medical care; stand-alone VCT facilities; and prevention of mother-to-child transmission (PMTCT) facilities, where testing is part of PMTCT services. Tests of bivariate associations and modified Poisson regression were used to assess significance and estimate the unadjusted and adjusted associations between modes of testing and outcome measures. In total, 2,116 respondents tested in 2007 or later reported on their testing experience. High percentages of clients across countries and modes of testing reported receiving recommended services and being satisfied. In the unadjusted analyses, integrated testers were less likely to meet with a counselor before testing (83% compared with 95% of VCT testers; p<0.001), but those who had a pre-test meeting were more likely to have completed consent procedures (89% compared with 83% among VCT testers; p<0.001) and pre-test counseling (78% compared with 73% among VCT testers; p = 0.015). Both integrated and PMTCT testers were more likely to receive complete post-test counseling than were VCT testers (59% among both PMTCT

  18. The comparative performance of the single intradermal comparative tuberculin test in Irish cattle, using tuberculin PPD combinations from different manufacturers.

    Science.gov (United States)

    Good, M; Clegg, T A; Murphy, F; More, S J

    2011-07-05

    Ireland currently obtains its avian and bovine tuberculin purified protein derivatives (PPDs) from a single source. Because problems of supply or quality cannot be discounted, it is prudent that Ireland identify alternative supplier(s) as part of a broad risk management strategy. Therefore, the aim of this study was to compare the performance of a number of different tuberculin combinations (that is, pairings of bovine and avian PPD; with different manufacturers) in the single intradermal comparative tuberculin test (SICTT), as currently performed in Ireland. The study was randomised, controlled and double-blinded. A total of 2172 cattle were used in the study. Each animal was tested using two SICTTs, the first based on the tuberculin combination in current use, and the second using one of six trial tuberculin combinations. Analyses were conducted to compare both reactor-status and skin increase. For each control/trial tuberculin combination, there was good agreement between the control and trial reactor-status. Differences in skin increases were mainly confined to animals categorised as either negative or severe inconclusive. However, the measured differences were minor, and unlikely to have a significant impact on the actual test outcome, either for individual animals or for herds. In conclusion, while further studies determining sensitivity and specificity in Ireland would have to be done in the event of a change in tuberculin PPD there should be minimal disruption of the national programme if alternative tuberculin PPDs meeting WHO, OIE and EU regulations were used. In this study, the precision of the guinea pig bio-assay to assess tuberculin potency was low and therefore Ireland should maintain its practice of periodically assessing potency in naturally infected cattle, even though this is not currently required under WHO, OIE or EU Regulations. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Assessing the representativeness of durability tests for wood pellets by DEM Simulation - Comparing conditions in a durability test with transfer chutes

    Science.gov (United States)

    Mahajan, Aditya; Dafnomilis, Ioannis; Hancock, Victoria; Lodewijks, Gabriel; Schott, Dingena

    2017-06-01

    Dust generation when handling wood pellets is related to the durability of the product, in other words the wear rate of particles subject to forces. During transport, storage and handling wood pellets undergo different forces when interacting with different pieces of equipment. This paper assesses the representativeness of the tumbling can test in relation to transfer chutes, by comparing forces acting on wood pellets in durability tests and in transfer chutes using DEM. The study also incorporates effects such as shape and size variations. The results showed that the tumbling can test underestimates compressive and tangential forces. Since the tested material is subject to milder conditions than in reality, it can be concluded that this test is not representative for the conditions in the supply chain of wood pellets.

  20. CANTAB object recognition and language tests to detect aging cognitive decline: an exploratory comparative study

    Directory of Open Access Journals (Sweden)

    Cabral Soares F

    2014-12-01

    Full Text Available Fernanda Cabral Soares,1 Thaís Cristina Galdino de Oliveira,1 Liliane Dias e Dias de Macedo,1 Alessandra Mendonça Tomás,1 Domingos Luiz Wanderley Picanço-Diniz,2 João Bento-Torres,1,3 Natáli Valim Oliver Bento-Torres,1,3 Cristovam Wanderley Picanço-Diniz1 1Universidade Federal do Pará, Instituto de Ciências Biológicas, Hospital Universitário João de Barros Barreto, Laboratório de Investigações em Neurodegeneração e Infecção Belém, Pará, Brazil; 2Universidade Federal do Oeste do Pará, Núcleo Universitário de Oriximiná, Oriximiná, Pará, Brazil; 3Faculdade de Fisioterapia e Terapia Ocupacional, Universidade Federal do Pará, Belém, Pará, BrazilObjective: The recognition of the limits between normal and pathological aging is essential to start preventive actions. The aim of this paper is to compare the Cambridge Neuropsychological Test Automated Battery (CANTAB and language tests to distinguish subtle differences in cognitive performances in two different age groups, namely young adults and elderly cognitively normal subjects.Method: We selected 29 young adults (29.9±1.06 years and 31 older adults (74.1±1.15 years matched by educational level (years of schooling. All subjects underwent a general assessment and a battery of neuropsychological tests, including the Mini Mental State Examination, visuospatial learning, and memory tasks from CANTAB and language tests. Cluster and discriminant analysis were applied to all neuropsychological test results to distinguish possible subgroups inside each age group.Results: Significant differences in the performance of aged and young adults were detected in both language and visuospatial memory tests. Intragroup cluster and discriminant analysis revealed that CANTAB, as compared to language tests, was able to detect subtle but significant differences between the subjects.Conclusion: Based on these findings, we concluded that, as compared to language tests, large-scale application

  1. The cost efficiency of exploratory testing:ISTQB certified testing compared with RST

    OpenAIRE

    Niittyviita, S. (Sampo)

    2017-01-01

    Abstract The research of software testing and the practices of software testing in the industry are separated by gaps in some areas. One such gap regards Exploratory Testing (ET). ET is probably the most widely used software testing approach in the industry, yet it is lacking research and many of the manuals of software engineering either ignore or look down on it. In addition, ET has the absence of widespread methodology a...

  2. Comparative studies of radioimmunologic serumtrypsin identifications and secretin-pancreozymin probe tests

    International Nuclear Information System (INIS)

    Scheithauer, R.

    1980-01-01

    In 29 patients with suspicion of a pancreatic disease, parallel to the classic secretin-pancreozymin test, the trypsin concentration was investigated basally and after stimulation by radioimmunological procedures. The basal mean value of the serum trypsin concentration was in those patients with sound pancreas 175 ng BIT/ml with limit values of 90 and 250 ng BIT/ml. The maximum value after stimulation was found in normal and pathologic cases 20 minutes after intravenous secretin administration (S 20), at most one sample earlier or later. The values ranged between 110 and 550 ng BIT/ml. The additional secretin-pancreozymin infusion did not lead to any further results. The quality investigation of the RIA in 9 cultures with 24 test sera showed in the lower measuring range a very high degree of liability (average concentration 188,7 ng BIT/ml) with a calculatory debit of 187,5 with maximum deviations of -17 and +25%, in the medium range they presented a sufficient liability, in high concentration dilution was necessary. The advantage of the tested procedure compared to the technically demanding SP test, i.e. the elimination of the deep sounding of the duodenum, has to be pointed out particularly. The discomfort for the patient is confined to two withdrawals of blood, basally and 20 minutes after exclusive secretin stimulation. (orig./MG) [de

  3. Assessment of Color Vision Among School Children: A Comparative Study Between The Ishihara Test and The Farnsworth D-15 Test

    Directory of Open Access Journals (Sweden)

    Rajesh Kishor Shrestha

    2016-10-01

    Full Text Available Introduction: Color vision is one of the important attribute of visual perception. The study was conducted at different schools of Kathmandu to compare the  ndings of the Ishihara Pseudoisochromatic test and the Farnsworth D-15 test.  Method: A cross-sectional study was conducted among 2120 students of four schools of Kathmandu. Assessment included visual acuity measurement, slit lamp examination of anterior segment and fundus examination with direct ophthalmoscopy. Each student was assessed with the Ishihara pseudoisochromatic test and the Farnsworth D-15 test. The Chi-square test was performed to analyse color vision defect detected by the Ishihara test and the Farnsworth D-15 test. Results: A total of 2120 students comprising of 1114 males (52.5% and 1006 females (47.5% were recruited in the study with mean age of 12.2 years (SD 2.3 years. The prevalence of color vision defect as indicated by the Ishihara was 2.6 and as indicated by the D-15 test was 2.15 in males.  Conclusion: For school color vision screening, the Ishihara color test and the Farnsworth D-15 test have equal capacity to detect congenital color vision defect and they complement each other.  Keywords: color vision; children; defect; Farnsworth D-15; Ishihara.

  4. Comparative thermal cyclic testing and strength investigation of different Be/Cu joints

    Energy Technology Data Exchange (ETDEWEB)

    Gervash, A.; Giniyatulin, R.; Komarov, V.; Mazul, I.; Litunovsky, N. [Research Inst. of Electrophysical Apparatus, St. Petersburg (Russian Federation); Ganenko, A.; Vainerman, A. [CRISM `Prometey`, 193167, St. Petersburg (Russian Federation); Fedotov, V. [Moscow Physical Engineering Institute, 123060, Moscow (Russian Federation); Davydov, D. [Bochvar Institute, 123060, Moscow (Russian Federation); Zalavutdinov, R. [Institute of Physical Chemistry, Moscow (Russian Federation)

    1998-09-01

    One of the main problems for ITER divertor target technology is to provide a reliable joint between Be as armour material and copper alloy heat-sink structure. Such joints are to satisfy numerous requirements. In particular these joints should successfully withstand cyclic hear fluxes and should have good properties after neutron irradiation. To study such a complex problem, several investigation stages were planed in Russia. This paper presents the results of comparative thermal cyclic testing of different Be/Cu candidates. Summarising the thermal cyclic test results and analysing the metallography of those joints it was found that the life-time of all tested joints is limited by rather thick brittle intermetallic layers in the bonding zone caused by relatively long brazing time using heating and cooling down in traditional ohmic furnace. This paper thus presents attempts of using a unique brazing technique with fast e-beam heating. Metallographic investigation as well as X-ray spectrometric analysis of joints produced using the new technique were done. The recent results of testing of Be/Cu joints produced by fast e-beam brazing are discussed and some ideas for the nearest future investigations are presented. (orig.) 5 refs.

  5. Comparative thermal cyclic testing and strength investigation of different Be/Cu joints

    International Nuclear Information System (INIS)

    Gervash, A.; Giniyatulin, R.; Komarov, V.; Mazul, I.; Litunovsky, N.; Ganenko, A.; Vainerman, A.; Fedotov, V.; Davydov, D.; Zalavutdinov, R.

    1998-01-01

    One of the main problems for ITER divertor target technology is to provide a reliable joint between Be as armour material and copper alloy heat-sink structure. Such joints are to satisfy numerous requirements. In particular these joints should successfully withstand cyclic hear fluxes and should have good properties after neutron irradiation. To study such a complex problem, several investigation stages were planed in Russia. This paper presents the results of comparative thermal cyclic testing of different Be/Cu candidates. Summarising the thermal cyclic test results and analysing the metallography of those joints it was found that the life-time of all tested joints is limited by rather thick brittle intermetallic layers in the bonding zone caused by relatively long brazing time using heating and cooling down in traditional ohmic furnace. This paper thus presents attempts of using a unique brazing technique with fast e-beam heating. Metallographic investigation as well as X-ray spectrometric analysis of joints produced using the new technique were done. The recent results of testing of Be/Cu joints produced by fast e-beam brazing are discussed and some ideas for the nearest future investigations are presented. (orig.)

  6. [The elaboration of aggressiveness in adolescence: Comparative structural study based on the Rorschach test].

    Science.gov (United States)

    Schiltz, L; Diwo, R; de Tychey, C

    2015-09-01

    In adolescence, a component of a successful identity quest consists in elaborating the aggressiveness, be it endured or acted out, in an imaginary and symbolic manner. We will present a comparative study between anxious and violent adolescents, based on the Rorschach test. As the handling of aggressiveness by means of various defense mechanisms and coping strategies contributes to the construction of a sense of reality and of coherent representations of oneself and the others, the Rorschach test is a pertinent tool to study the vicissitudes of the identity quest of medium adolescence. On the other hand, many studies demonstrate that it is also a precious tool allowing diagnosis of the risks of evolution towards character pathology and personality disorders belonging to cluster B of the DSM, or towards emotional disorders and suicidal tendencies. Thus, it can help initiating appropriate therapeutic measures in a spirit of tertiary prevention. We present a comparative study between a sample of 20 adolescents suffering from anxiety and inhibition of aggressiveness (subgroup anxiety) and a second sample of 20 adolescents suffering from exteriorized aggressiveness and violent behavior (subgroup violence). The inclusion into the subgroups was based on clinical interviews and a thorough psychological assessment, using the criteria of categorical psychopathology. The comparative study between the two subgroups is based on an original rating scale constructed in the phenomenological and structural tradition, reflecting the global judgment of the experienced clinical psychologist. It permits using the Rorschach test as a research tool by making the step from qualitative analysis towards quantification and the use of inferential and multidimensional statistics. It also allows computing correlations between the Rorschach test and psychometric scales or other projective tests, using specific rating scales of the same type. After showing the descriptive demographic data, we

  7. Comparing interferometry techniques for multi-degree of freedom test mass readout

    International Nuclear Information System (INIS)

    Isleif, Katharina-Sophie; Gerberding, Oliver; Mehmet, Moritz; Schwarze, Thomas S; Heinzel, Gerhard; Danzmann, Karsten

    2016-01-01

    Laser interferometric readout systems with 1pm/Hz precision over long time scales have successfully been developed for LISA and LISA Pathfinder. Future gravitational physics experiments, for example in the fields of gravitational wave detection and geodesy, will potentially require similar levels of displacement and tilt readouts of multiple test masses in multiple degrees of freedom. In this article we compare currently available classic interferometry schemes with new techniques using phase modulations and complex readout algorithms. Based on a simple example we show that the new techniques have great potential to simplify interferometric readouts. (paper)

  8. Analyzing and comparing the dynamic response of test reactor main workshop

    International Nuclear Information System (INIS)

    Wang Jiachun; Fu Jiyang; Cai Laizhong

    2001-01-01

    Analyzing soil-structure interaction is an important section in anti-seismic design and analysis of nuclear engineering. The factors that influence on the response of nuclear structures include the properties of earthquake, soil and structures. So the soil-structure interaction in the non-rock foundation is different from that in the surface free field. And the interaction must be considered under the anti-seismic design standard of test reactors. The FLUSH program and SASSI2000 are applied to dynamic analysis. Moreover, comparing the obtained data and diagrams draws some conclusions

  9. Basin sidewall effects during comparable boom testing

    International Nuclear Information System (INIS)

    DeVitis, D.S.; Hannon, L.

    1995-01-01

    A quantitative investigation of the effects of boom sidewall clearance during first and gross oil loss speed tests was discussed. A second measure of sidewall was quantified in terms of flow characteristics at specific location in the boom apex. The test boom was rigged in 5 different configurations. First oil loss and gross oil loss tow speeds, and relative horizontal flow velocities within the boom apex were obtained for each configuration. Flow velocities of 0.5 to 1.5 knots in 0.25 knot increments were measured. Flow velocities illustrated similar flow characteristics within the apex regardless of side wall clearance. The results of the study illustrated that boom to basin sidewall clearance may be an independent test parameter without a significant bias. 5 tabs., 8 figs.,

  10. Using latent class analysis to estimate the test characteristics of the γ-interferon test, the single intradermal comparative tuberculin test and a multiplex immunoassay under Irish conditions

    DEFF Research Database (Denmark)

    Clegg, Tracy A.; Duignan, Anthony; Whelan, Clare

    2011-01-01

    Considerable effort has been devoted to improving the existing diagnostic tests for bovine tuberculosis (single intradermal comparative tuberculin test [SICTT] and ¿-interferon assay [¿-IFN]) and to develop new tests. Previously, the diagnostic characteristics (sensitivity, specificity) have been...... estimated in populations with defined infection status. However, these approaches can be problematic as there may be few herds in Ireland where freedom from infection is guaranteed. We used latent class models to estimate the diagnostic characteristics of existing (SICTT and ¿-IFN) and new (multiplex...... immunoassay [Enferplex-TB]) diagnostic tests under Irish field conditions where true disease status was unknown. The study population consisted of herds recruited in areas with no known TB problems (2197 animals) and herds experiencing a confirmed TB breakdown (2740 animals). A Bayesian model was developed...

  11. Comparative analysis of quality control tests on computed tomography in accordance with national and international laws

    International Nuclear Information System (INIS)

    Ramos, Fernando S.; Vasconcelos, Rebeca S.; Goncalves, Marcel S.; Oliveira, Marcus V.L. de

    2014-01-01

    The objective of this study is to perform a comparative analysis between the Brazilian legislation and internationals protocols, with respect to the quality control tests for computerized tomography. We used 07 references, published from 1998-2012: the Protocolo Brasileiro - Portaria 453/98 SVS/MS and the Guia de Radiodiagnostico Medico da ANVISA; Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications of the IAEA; European Protocol - European Guidelines on Quality Criteria for Computed Tomography of the EUR No. 16262 EN; Radiation Protection No. 162 - Criteria for Acceptability of Medical Radiology, Nuclear Medicine and Radiotherapy of the European Commission; the Protocols of Control de Calidad en Radiodiagnostico IAEA / ARCAL XLIX; and the Protocolo Espanol de Control de Calidad en Radiodignostico. The comparative analysis of these legislations was based on aspects of tolerance / limit, frequency and objectives of the recommended tests. Were found 18 tests in the Brazilian legislation. The tests were grouped according to their nature (dosimetric tests / exposure and geometric tests and image quality tests). Among the evaluated protocols was identified divergence between tests contained in the documents and the criteria of assessment set out in this work. It is clear, moreover, that for certain documents are not observed tolerances, well-defined methodologies and even frequency of testing. We conclude that the current legislation in Brazil differs in certain respects from international protocols analyzed, although this has a great numbers of quality control tests. However, it is necessary that the Brazilian legislation takes into account technological advances presented to time

  12. Utility of a rapid immunochromatographic strip test in detecting canine parvovirus infection compared with polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Sundaran S. Tinky

    2015-04-01

    Full Text Available Aim: The present study was undertaken to detect the presence of canine parvovirus (CPV in fecal samples of diarrheic dogs by conventional polymerase chain reaction (PCR and immunochromatographic (IC strip test and to compare the diagnostic potential of these tests. Materials and Methods: A total of 50 fecal samples collected from diarrheic dogs suspected for CPV infection were subjected to PCR using CPV-555 primer amplifying the gene coding for the VP1 protein. These samples were also tested by IC strip test using a commercial rapid Ag test kit. The results were statistically analyzed using McNemar test. Results: A total of 22 samples (44% were detected as positive by PCR, which yielded a specific amplicon of 583 bp. In IC strip test, 18 (36% samples were found to be positive. The sensitivity of the test as compared to PCR was found to be 72.22% and specificity was 92.86%. Positive predictive value and negative predictive value of IC strip test was found to be 88.89% and 81.25%, respectively. Statistical analysis of the results of PCR and IC assay using McNemar test revealed no significant difference (p>0.05. Conclusion: The IC strip test could be employed as a rapid field level diagnostic tool for the diagnosis of canine parvoviral diarrhea.

  13. Screening of Plant Extracts for Antioxidant Activity: a Comparative Study on Three Testing Methods

    NARCIS (Netherlands)

    Koleva, I.; Beek, van T.A.; Linssen, J.P.H.; Groot, de Æ.; Evstatieva, L.N.

    2002-01-01

    Three methods widely employed in the evaluation of antioxidant activity, namely 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging method, static headspace gas chromatography (HS-GC) and -carotene bleaching test (BCBT), have been compared with regard to their application in the screening of

  14. Intra-operative Assessment of the Spinal Cord Function: Awakening Compared to Ankle Clonus Test

    International Nuclear Information System (INIS)

    Amin, Wafik A.; Tealab, Ayman I.; Ei-Gendy, Eslah H.; Esmat, Hesham A.

    2006-01-01

    The spinal cord is at high risk of injury during special procedures such as correction of scoliosis. Recovery from impairement is directly proportional to the time of removal of the instrumentations. For this, methods used to detect the neurologic injury should be continuous, fast, sensitive and specific. The present study was performed to evaluate the ankle clonus as a test for the integrity of the spinal cord function intraoperatively. Twenty eight scoliotic patients were included in the study. The ankle clonus was tested before, during and after the correction and fixation followed by the wake-up test to correlate the results of both rests. The haemodynamics changes at the time of the two tests were compared. It was found out that, the ankle clonus test correlated well with the wake-up test, with only two false positive results. No false negative results were recorded which was an important finding. The haemodynamic changes were better during the ankle clonus test than during the wake-up test. It was concluded that the ankle clonus test is reliable, safe, and faster than the wake-up test. It is recommended to use the test to evaluate the integrity of the spinal cord during the operations with potential risk to the cord. In case the result of the ankle clonus is positive, the wake-up test should be done before an attempt to release or remove the instrumentations. (author)

  15. Palm oil as a fuel for agricultural diesel engines: Comparative testing against diesel oil

    Directory of Open Access Journals (Sweden)

    Teerawat Apichato

    2003-05-01

    Full Text Available Due to unstable oil price situation in the world market, many countries have been looking for alternative energy sources to substitute for petroleum. Vegetable oil is one of the alternatives which can be used as fuel in automotive engines either in the form of straight vegetable oil, or in the form of ethyl or methyl ester. This paper presents a comparative performance testing of diesel engine using diesel oil and refined palm oil over 2,000 hours of continuous running time. Short-term performance testing was conducted for each fuel on the dynamometer engine test bed. Specific fuel consumption, exhaust temperature and black smoke density were determined and measured. Long-term performance testing (or endurance test was also done by running the engines coupled with a generator in order to supply load (electricity to a lightbulb board. For each 500 hours of engine run time, the engines were dissembled for engine wear inspection. It was found that the fuel pump and fuel valve weight losses from both engines showed insignificant differences either at the first 500 hours of running time or at the second 500 hours of running time but the inlet valve from the engine fueled by diesel oil had a higher weight loss than the engine fueled by refined palm oil at the first 500 hours and at the second 500 hours of running time. The compression rings from the engine fueled by refined palm oil showed a significant weight loss compared to the engine fueled by diesel oil both after 500 hours and after 1000 hours of running time.

  16. False-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis

    Directory of Open Access Journals (Sweden)

    Rudielle A. Rodrigues

    Full Text Available ABSTRACT: According to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT, the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT of the Ministry of Agriculture, Livestock and Food Supply (MAPA, the caudal fold test and the comparative intradermal tuberculin test (CITT. The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4% were negative, 14 (26.4% were positive and seven (13.2% results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0% of the animals with negative CITT results were culture positive (confirmed by PCR and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary tests could help identify such animals and increase the odds of diagnostic success.

  17. Comparative Study of Frederikshavn Field Tests

    DEFF Research Database (Denmark)

    Firouzianbandpey, Sarah

    This report contains the results and experiences from a large scale test on a bucket foundation located in saturated sand. The experiment is a part of a large research and development program concerning bucket foundations for offshore wind turbines. The research program is a co-operation between...

  18. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Effectiveness testing of some vegetal extracts comparing with clasical anthelmintics

    Directory of Open Access Journals (Sweden)

    Ilie M.S.,

    2007-12-01

    Full Text Available We have tested the efficacy of some vegetal extracts (Parazitol –Medica Laboratories, a natural product with an anthelmintic effect and a Cucurbita sp. oil extract compared to the classic anthelmintics (Rombendazol – Romvac and Dehelman – KRKA Slovenia at domestic poultry, whose parasitical status had been previously established through animal killing and necropsies. Parazitol and the pumpkin oil have had a lower efficacy than the levamisole and albendazole upon the species Ascaridia galli. Heterakis gallinarum was not affected by the pumpkin oil. Parazitol have a moderate efficacy (36%, while levamisole and albendazole were very efficient (100%. The treatments with albendazole upon the cestods belonging to the genus Raillietina have had a 100% efficacy. In cestods, Parazitol had a better efficacy (57% than the pumpkin oil (14%.

  20. A comparative study of the typhidot (Dot-EIA) and Widal tests in blood culture positive cases of typhoid fever.

    Science.gov (United States)

    Khoharo, Haji Khan

    2011-07-01

    Seventy-six blood culture positive typhoid cases and forty-eight controls were studied. The typhidot test was positive in 74 (97.36%) cases, with a sensitivity, specificity and positive predictive value of 96%, 89.5%, and 95%, respectively, compared to the Widal test which was positive in 56 (73.68%) cases with a sensitivity, specificity, and positive predictive value of 72%, 87%, and 87%, respectively (P = 0.001). In the control group, seven (14.5%) cases tested positive for the Widal test and two (4.16%) for the typhidot (P = 0.001), yielding the sensitivity and specificity for the Widal test and the typhidot test of 63% and 83%, and 85% and 97%, respectively. We conclude that the Dot-EIA (enzyme immunoassay; typhidot) is a more sensitive and specific test which is easy to perform and more reliable compared to the Widal test and that it is useful in early therapy.

  1. ACL injury: How do the physical examination tests compare?

    Science.gov (United States)

    Koster, Christiaan H; Harmsen, Annelieke Mk; Lichtenberg, Miranda C; Bloemers, Frank W

    2018-03-01

    Three physical examination tests are most commonly used to evaluate cruciate ligament injury. The best known and most frequently used technique is the anterior drawer test. The other 2 tests, the Lachman test and the pivot shift test, are more difficult to perform and are used less often, especially by physicians untrained in their use. In addition, there is a relatively new diagnostic test: the lever sign test. The aim of our article is to provide a short, clinically relevant overview of the literature and to assess the diagnostic value of physical examination for the primary care physician.

  2. Cosmological Non-Gaussian Signature Detection: Comparing Performance of Different Statistical Tests

    Directory of Open Access Journals (Sweden)

    O. Forni

    2005-09-01

    Full Text Available Currently, it appears that the best method for non-Gaussianity detection in the cosmic microwave background (CMB consists in calculating the kurtosis of the wavelet coefficients. We know that wavelet-kurtosis outperforms other methods such as the bispectrum, the genus, ridgelet-kurtosis, and curvelet-kurtosis on an empirical basis, but relatively few studies have compared other transform-based statistics, such as extreme values, or more recent tools such as higher criticism (HC, or proposed “best possible” choices for such statistics. In this paper, we consider two models for transform-domain coefficients: (a a power-law model, which seems suited to the wavelet coefficients of simulated cosmic strings, and (b a sparse mixture model, which seems suitable for the curvelet coefficients of filamentary structure. For model (a, if power-law behavior holds with finite 8th moment, excess kurtosis is an asymptotically optimal detector, but if the 8th moment is not finite, a test based on extreme values is asymptotically optimal. For model (b, if the transform coefficients are very sparse, a recent test, higher criticism, is an optimal detector, but if they are dense, kurtosis is an optimal detector. Empirical wavelet coefficients of simulated cosmic strings have power-law character, infinite 8th moment, while curvelet coefficients of the simulated cosmic strings are not very sparse. In all cases, excess kurtosis seems to be an effective test in moderate-resolution imagery.

  3. First level analysis report: comparative testing of HVS Mk IV+ and HVS Mk III on road D2388 near Cullinan

    CSIR Research Space (South Africa)

    Morton, B

    2003-03-01

    Full Text Available , result in variations in pavement response and test results. Based on this concern and in an effort to ensure uniformity throughout APT with the HVS, a comparative testing project was initiated to compare the effect of the two machines on pavement...

  4. Distinguishing Depressive Pseudodementia from Alzheimer Disease: A Comparative Study of Hippocampal Volumetry and Cognitive Tests

    Directory of Open Access Journals (Sweden)

    Sevki Sahin

    2017-07-01

    Full Text Available Background and Aim: Depressive pseudodementia (DPD is a condition which may develop secondary to depression. The aim of this study was to contribute to the differential diagnosis between Alzheimer disease (AD and DPD by comparing the neurocognitive tests and hippocampal volume. Materials and Methods: Patients who met criteria of AD/DPD were enrolled in the study. All patients were assessed using the Wechsler Memory Scale (WMS, clock-drawing test, Stroop test, Benton Facial Recognition Test (BFRT, Boston Naming Test, Mini-Mental State Examination (MMSE, and Geriatric Depression Scale (GDS. Hippocampal volume was measured by importing the coronal T1-weighted magnetic resonance images to the Vitrea 2 workstation. Results: A significant difference was found between the AD and DPD groups on the WMS test, clock-drawing test, Stroop test, Boston Naming Test, MMSE, GDS, and left hippocampal volume. A significant correlation between BFRT and bilateral hippocampal volumes was found in the AD group. No correlation was found among parameters in DPD patients. Conclusions: Our results suggest that evaluation of facial recognition and left hippocampal volume may provide more reliable evidence for distinguishing DPD from AD. Further investigations combined with functional imaging techniques including more patients are needed.

  5. Automotive RF immunity test set-up analysis : why test results can't compare

    NARCIS (Netherlands)

    Coenen, Mart; Pues, H.; Bousquet, T.

    2011-01-01

    Though the automotive RF emission and RF immunity requirements are highly justifiable, the application of those requirements in an non-intended manner leads to false conclusions and unnecessary redesigns for the electronics involved. When the test results become too dependent upon the test set-up

  6. Incorporating comparative genomics into the design-test-learn cycle of microbial strain engineering.

    Science.gov (United States)

    Sardi, Maria; Gasch, Audrey P

    2017-08-01

    Engineering microbes with new properties is an important goal in industrial engineering, to establish biological factories for production of biofuels, commodity chemicals and pharmaceutics. But engineering microbes to produce new compounds with high yield remains a major challenge toward economically viable production. Incorporating several modern approaches, including synthetic and systems biology, metabolic modeling and regulatory rewiring, has proven to significantly advance industrial strain engineering. This review highlights how comparative genomics can also facilitate strain engineering, by identifying novel genes and pathways, regulatory mechanisms and genetic background effects for engineering. We discuss how incorporating comparative genomics into the design-test-learn cycle of strain engineering can provide novel information that complements other engineering strategies. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Social inequality and HIV-testing: Comparing home- and clinic-based testing in rural Malawi

    Directory of Open Access Journals (Sweden)

    Alexander A. Weinreb

    2009-10-01

    Full Text Available The plan to increase HIV testing is a cornerstone of the international health strategy against the HIV/AIDS epidemic, particularly in sub-Saharan Africa. This paper highlights a problematic aspect of that plan: the reliance on clinic- rather than home-based testing. First, drawing on DHS data from across Africa, we demonstrate the substantial differences in socio-demographic and economic profiles between those who report having ever had an HIV test, and those who report never having had one. Then, using data from a random household survey in rural Malawi, we show that substituting home-based for clinic-based testing may eliminate this source of inequality between those tested and those not tested. This result, which is stable across modeling frameworks, has important implications for accurately and equitably addressing the counseling and treatment programs that comprise the international health strategy against AIDS, and that promise to shape the future trajectory of the epidemic in Africa and beyond.

  8. Comparing the disk-diffusion and agar dilution tests for Neisseria gonorrhoeae antimicrobial susceptibility testing

    Directory of Open Access Journals (Sweden)

    Hsi Liu

    2016-11-01

    Full Text Available Abstract Background We assessed the validity of testing for antimicrobial susceptibility of clinical and mutant Neisseria gonorrhoeae (GC isolates by disk diffusion in comparison to agar dilution, and Etest® (bioMerieux, France, respectively, for three third generation extended spectrum cephalosporins (ESC: ceftriaxone (CRO, cefixime (CFX, and cefpodoxime (CPD. Methods One hundred and five clinical isolates and ten laboratory-mutants were tested following Clinical Laboratory Standard Institute (CLSI and manufacturer’s standards for each of the three methods. The measured diameters by the disk diffusion method were tested for correlation with the MIC values by agar dilution. In addition, comparisons with the Etest® were made. Categorical results for concordance, based on standard CLSI cutoffs, between the disk diffusion and the other two methods, respectively, were tested using the Chi-square statistics. Reproducibility was tested for CFX across a 6-month interval by repeated disk tests. Results Across all 115 specimens, the disk diffusion tests produced good categorical agreements, exhibiting concordance of 93.1%, 92.1%, and 90.4% with agar dilution and 93.0%, 92.1%, and 90.4% with Etest®, for CRO, CFX, and CPD, respectively. Pearson correlations between disk-diffusion diameters and agar dilution MIC’s were -0.59, -0.67, and -0.81 for CRO, CFX, and CPD, respectively. The correlations between disk diffusion and Etest® were -0.58, -0.73, and -0.49. Pearson correlation between the CFX disk readings over a 6-month interval was 91%. Conclusions Disk diffusion tests remain to be a useful, reliable and fast screening method for qualitative antimicrobial susceptibility testing for ceftriaxone, cefixime, and cefpodoxime.

  9. Toward laboratory blood test-comparable photometric assessments for anemia in veterinary hematology

    Science.gov (United States)

    Kim, Taehoon; Choi, Seung Ho; Lambert-Cheatham, Nathan; Xu, Zhengbin; Kritchevsky, Janice E.; Bertin, Francois-René; Kim, Young L.

    2016-10-01

    Anemia associated with intestinal parasites and malnutrition is the leading cause of morbidity and mortality in small ruminants worldwide. Qualitative scoring of conjunctival redness has been developed so that farmers can gauge anemia in sheep and goats to identify animals that require treatment. For clinically relevant anemia diagnosis, complete blood count-comparable quantitative methods often rely on complicated and expensive optical instruments, requiring detailed spectral information of hemoglobin. We report experimental and numerical results for simple, yet reliable, noninvasive hemoglobin detection that can be correlated with laboratory-based blood hemoglobin testing for anemia diagnosis. In our pilot animal study using calves, we exploit the third eyelid (i.e., palpebral conjunctiva) as an effective sensing site. To further test spectrometer-free (or spectrometerless) hemoglobin assessments, we implement full spectral reconstruction from RGB data and partial least square regression. The unique combination of RGB-based spectral reconstruction and partial least square regression could potentially offer uncomplicated instrumentation and avoid the use of a spectrometer, which is vital for realizing a compact and inexpensive hematology device for quantitative anemia detection in the farm field.

  10. Performing T-tests to Compare Autocorrelated Time Series Data Collected from Direct-Reading Instruments.

    Science.gov (United States)

    O'Shaughnessy, Patrick; Cavanaugh, Joseph E

    2015-01-01

    Industrial hygienists now commonly use direct-reading instruments to evaluate hazards in the workplace. The stored values over time from these instruments constitute a time series of measurements that are often autocorrelated. Given the need to statistically compare two occupational scenarios using values from a direct-reading instrument, a t-test must consider measurement autocorrelation or the resulting test will have a largely inflated type-1 error probability (false rejection of the null hypothesis). A method is described for both the one-sample and two-sample cases which properly adjusts for autocorrelation. This method involves the computation of an "equivalent sample size" that effectively decreases the actual sample size when determining the standard error of the mean for the time series. An example is provided for the one-sample case, and an example is given where a two-sample t-test is conducted for two autocorrelated time series comprised of lognormally distributed measurements.

  11. A spoon full of studies helps the comparison go down: A comparative analysis of Tulving’s spoon test

    Directory of Open Access Journals (Sweden)

    Damian eScarf

    2014-08-01

    Full Text Available Mental time travel refers to the ability to cast one’s mind back in time to re-experience a past event and forward in time to pre-experience events that may occur in the future. Endel Tulving (2005, an authority on mental time travel, holds that this ability is unique to humans. Anticipating that comparative psychologists would challenge this claim, Tulving (2005 proposed his spoon test, a test specifically designed to assess whether nonhuman animals are capable of mental time travel. A number of studies have now employed the spoon test to assess mental time travel in nonhuman animals. Here, we review the evidence for mental time travel in primates. To provide a benchmark, we also review studies that have employed the spoon test with preschool children. The review demonstrates that if we compare the performance of great apes to that of preschool children, and hold them to the same criteria, the data suggest mental travel is present but not ubiquitous in great apes.

  12. Comparing statistical tests for detecting soil contamination greater than background

    International Nuclear Information System (INIS)

    Hardin, J.W.; Gilbert, R.O.

    1993-12-01

    The Washington State Department of Ecology (WSDE) recently issued a report that provides guidance on statistical issues regarding investigation and cleanup of soil and groundwater contamination under the Model Toxics Control Act Cleanup Regulation. Included in the report are procedures for determining a background-based cleanup standard and for conducting a 3-step statistical test procedure to decide if a site is contaminated greater than the background standard. The guidance specifies that the State test should only be used if the background and site data are lognormally distributed. The guidance in WSDE allows for using alternative tests on a site-specific basis if prior approval is obtained from WSDE. This report presents the results of a Monte Carlo computer simulation study conducted to evaluate the performance of the State test and several alternative tests for various contamination scenarios (background and site data distributions). The primary test performance criteria are (1) the probability the test will indicate that a contaminated site is indeed contaminated, and (2) the probability that the test will indicate an uncontaminated site is contaminated. The simulation study was conducted assuming the background concentrations were from lognormal or Weibull distributions. The site data were drawn from distributions selected to represent various contamination scenarios. The statistical tests studied are the State test, t test, Satterthwaite's t test, five distribution-free tests, and several tandem tests (wherein two or more tests are conducted using the same data set)

  13. A Study of the Equality of Cable Insulations by comparing aging trend using an Oxidation Induction Time Measurement Test

    International Nuclear Information System (INIS)

    Park, Kyungheum; Bhang, Keugjin; Jeong, Sunchul

    2014-01-01

    Usually, the environmental qualification test is carried out by the cable manufacturer and the test report is presented while the cable manufacturer supplies the tested cables in nuclear power plant. If a cable manufacturer has environmentally qualified a cable for nuclear power plant more than a decade ago and the composition of the cable material is same, is it acceptable to use the old EQ report for recently manufactured cable? Even though the manufacturer insists the composition of the tested cable and recently manufactured cable's material are same, there can some questions or opposing opinions for two cables, tested cable and recently manufactured cable's equality. In this case, how can I determine the equality for the two cables? It is well known method to use FT-IR to determine the similarity of cable materials. FT-IR is easy tool to compare compositions of each material. But FT-IR method is not proper to compare aging trend of these materials. Oxidation induction time(OIT) testing is a technique that can be used to evaluate aging of organic materials and life assessment technique for cables used in nuclear power plants. In this paper, I studied the OIT technique to compare aging trend for the tested cable and recently manufactured cable to determine the equality for the two cables. To study a equality analysis for cable materials, OIT measurement tests were performed for two cable insulation(produced in 1995 and produced in 2013) which were supplied from same manufacturer. The two cables were irradiated up to 40 Mrad to simulate normal 40 years and thermally aged for 144 hours at 170 .deg. C equals to 40 years qualified life at 90 .deg. C. The OIT measurement were made in order to compare aging trends of the '95 cable and the '13 cable, the test were performed for three sequential steps; initial, after Normal Radiation and after Thermal Aging. The OIT measurement results at the temperature of 225 .deg. C showed very similar degradation

  14. Comparative evaluation of two rapid Salmonella-IgM tests and blood culture in the diagnosis of enteric fever.

    Science.gov (United States)

    Prasad, K J; Oberoi, J K; Goel, N; Wattal, C

    2015-01-01

    Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.

  15. A Comparative Analysis of Polymerase Chain Reaction and Direct Fluorescent Antibody Test for Diagnosis of Genital Herpes.

    Science.gov (United States)

    Patwardhan, Vrushali; Bhalla, Preena; Rawat, Deepti; Garg, Vijay Kumar; Sardana, Kabir; Sethi, Sumit

    2017-01-01

    To compare laboratory tests that can simultaneously detect and type herpes simplex virus (HSV) directly from the genital ulcer specimens in clinically suspected cases of genital herpes. A study was conducted over 10 months and 44 adult male and female patients clinically suspected with genital herpes were recruited. Genital ulcer swab specimens were subjected to glycoprotein-G gene-based conventional polymerase chain reaction (PCR) and commercially available direct fluorescent antibody (DFA) test and the results were compared. PCR for HSV was positive in 82% (36/44) cases. DFA was positive in 68.2% (30/44) cases. There was 100% agreement between HSV types detected by DFA and PCR. The strength of agreement between the results was better in primary genital herpes than recurrent cases. PCR was found to be better in the detection of HSV in recurrent genital herpes patients. It is a better modality, especially when genital herpes clinically presents with ulcerative or crusted lesions, and is also a cheaper alternative as compared to DFA.

  16. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    Science.gov (United States)

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical

  17. A framework for testing and comparing binaural models.

    Science.gov (United States)

    Dietz, Mathias; Lestang, Jean-Hugues; Majdak, Piotr; Stern, Richard M; Marquardt, Torsten; Ewert, Stephan D; Hartmann, William M; Goodman, Dan F M

    2018-03-01

    Auditory research has a rich history of combining experimental evidence with computational simulations of auditory processing in order to deepen our theoretical understanding of how sound is processed in the ears and in the brain. Despite significant progress in the amount of detail and breadth covered by auditory models, for many components of the auditory pathway there are still different model approaches that are often not equivalent but rather in conflict with each other. Similarly, some experimental studies yield conflicting results which has led to controversies. This can be best resolved by a systematic comparison of multiple experimental data sets and model approaches. Binaural processing is a prominent example of how the development of quantitative theories can advance our understanding of the phenomena, but there remain several unresolved questions for which competing model approaches exist. This article discusses a number of current unresolved or disputed issues in binaural modelling, as well as some of the significant challenges in comparing binaural models with each other and with the experimental data. We introduce an auditory model framework, which we believe can become a useful infrastructure for resolving some of the current controversies. It operates models over the same paradigms that are used experimentally. The core of the proposed framework is an interface that connects three components irrespective of their underlying programming language: The experiment software, an auditory pathway model, and task-dependent decision stages called artificial observers that provide the same output format as the test subject. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Radiologic findings after fundoplication compared with a pH reflux test and symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    In a follow-up after fundoplication, 61 patients underwent a double contrast examination of the stomach and a radiologic examination to detect any gastro-oesophageal reflux. The radiologic findings were compared with pH reflux test and symptoms. Gastro-oesophageal reflux was found in 7 patients at radiologic examination. None of these patients had an adequate fundoplication at a double contrast examination of the stomach and all had symptoms indicating reflux. Recurrence of gastro-oesophageal reflux may be shown at the radiologic examination and predicted by the morphologic appearances at the double contrast examination.

  19. Radiologic findings after fundoplication compared with a pH reflux test and symptoms

    International Nuclear Information System (INIS)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.; Linkoeping Univ.; Linkoeping Univ.

    1986-01-01

    In a follow-up after fundoplication, 61 patients underwent a double contrast examination of the stomach and a radiologic examination to detect any gastro-oesophageal reflux. The radiologic findings were compared with pH reflux test and symptoms. Gastro-oesophageal reflux was found in 7 patients at radiologic examination. None of these patients had an adequate fundoplication at a double contrast examination of the stomach and all had symptoms indicating reflux. Recurrence of gastro-oesophageal reflux may be shown at the radiologic examination and predicted by the morphologic appearances at the double contrast examination. (orig.)

  20. Avoiding pitfalls in molecular genetic testing: case studies of high-resolution array comparative genomic hybridization testing in the definitive diagnosis of Mowat-Wilson syndrome.

    Science.gov (United States)

    Kluk, Michael Joseph; An, Yu; James, Philip; Coulter, David; Harris, David; Wu, Bai-Lin; Shen, Yiping

    2011-05-01

    The molecular testing options available for the diagnosis of genetic disorders are numerous and include a variety of different assay platforms. The consultative input of molecular pathologists and cytogeneticists, working closely with the ordering clinicians, is often important for definitive diagnosis. Herein, we describe two patients who had long histories of unexplained signs and symptoms with a high clinical suspicion of an underlying genetic etiology. Initial molecular testing in both cases was negative, but the application of high-resolution array comparative genomic hybridization technology lead to definitive diagnosis in both cases. We summarize the clinical findings and molecular testing in each case, discuss the differential diagnoses, and review the clinical and pathological findings of Mowat-Wilson syndrome. This report highlights the importance for those involved in molecular testing to know the nature of the underlying genetic abnormalities associated with the suspected diagnosis, to recognize the limitations of each testing platform, and to persistently pursue repeat testing using high-resolution technologies when indicated. This concept is applicable to both germline and somatic molecular genetic testing. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  1. A cost-benefit model comparing the California Milk Cell Test and Milk Electrical Resistance Test.

    Science.gov (United States)

    Petzer, Inge-Marie; Karzis, Joanne; Meyer, Isabel A; van der Schans, Theodorus J

    2013-04-24

    The indirect effects of mastitis treatment are often overlooked in cost-benefit analyses, but it may be beneficial for the dairy industry to consider them. The cost of mastitis treatment may increase when the duration of intra-mammary infections are prolonged due to misdiagnosis of host-adapted mastitis. Laboratory diagnosis of mastitis can be costly and time consuming, therefore cow-side tests such as the California Milk Cell Test (CMCT) and Milk Electrical Resistance (MER) need to be utilised to their full potential. The aim of this study was to determine the relative benefit of using these two tests separately and in parallel. This was done using a partial-budget analysis and a cost-benefit model to estimate the benefits and costs of each respective test and the parallel combination thereof. Quarter milk samples (n= 1860) were taken from eight different dairy herds in South Africa. Milk samples were evaluated by means of the CMCT, hand-held MER meter and cyto-microbiological laboratory analysis. After determining the most appropriate cut-off points for the two cow-side tests, the sensitivity and specificity of the CMCT (Se= 1.00, Sp= 0.66), MER (Se= 0.92, Sp= 0.62) and the tests done in parallel (Se= 1.00, Sp= 0.87) were calculated. The input data that were used for partial-budget analysis and in the cost-benefit model were based on South African figures at the time of the study, and on literature. The total estimated financial benefit of correct diagnosis of host-adapted mastitis per cow for the CMCT, MER and the tests done in parallel was R898.73, R518.70 and R1064.67 respectively. This involved taking the expected benefit of a correct test result per cow, the expected cost of an error per cow and the cost of the test into account. The CMCT was shown to be 11%more beneficial than the MER test, whilst using the tests in parallel was shown to be the most beneficial method for evaluating the mastitis-control programme. Therefore, it is recommended that the

  2. A comparative study of stool antigen Immunocard STAT HpSA test with biopsy in diagnosis of H Pylori Infection

    Directory of Open Access Journals (Sweden)

    Munish Rastogi

    2015-12-01

    Full Text Available The present study was conducted on 78 cases in the Department of Medicine at G.S.V.M Medical College, Kanpur who reported with various gastrointestinal symptoms such as dyspepsia, heartburns, nausea, vomiting and loss of appetite. They all were advised for biopsy by the physician. Patients treated with antibiotics, bismuth or proton pump inhibitors within 4 weeks preceding the study were excluded. Invasive tests using mucosal biopsies including histology and rapid urease test (RUT were used to establish the gold standard in order to evaluate the accuracy of Immunocard STAT HpSA. Sensitivity, Specificity, Positive Predictive Value and Negative Predictive Value of Immunocard STAT HpSA as compared to gold standard were 95.5%, 81.8%, 96.9% and 75.0% respectively. It is thus concluded that the Immunocard STAT HpSA test has a diagnostic value comparable to the gold standard in detecting H Pylori. The sensitivity and specificity of the test is fair enough to be used as a test for screening purpose and also for diagnosis and treatment of H.Pylori infection in clinical practice

  3. Testing the usability of a personalized system: comparing the use of interviews, questionnaires and thinking -aloud

    NARCIS (Netherlands)

    van Velsen, Lex Stefan; van der Geest, Thea; Klaassen, R.F.

    2007-01-01

    Personalized systems present each user with tailored content or output. Testing the usability of such a system must take some specific usability issues and the suitability of the personalized output into account. In this study, we evaluated a personalized search engine to compare the use of

  4. Comparative study of the dental substrate used in shear bond strength tests

    Directory of Open Access Journals (Sweden)

    Lopes Murilo Baena

    2003-01-01

    Full Text Available The purpose of this study was to compare shear bond strength values obtained in human enamel and dentin with the values obtained in bovine teeth using two adhesive systems with different actions. Forty human tooth half-crowns and forty bovine tooth crowns were flattened to a minimum plain area of 5 mm in diameter. The samples were divided in four groups of 20 specimens each: 1 human enamel; 2 bovine enamel; 3 human dentin; 4 bovine dentin. The samples of each group were divided in 2 subgroups of 10 samples each, according to the adhesive system used: 1 Scotchbond Multi-Purpose (SBMP; and 2 Clearfil Liner Bond 2V (CLB2V applied according to the manufacturer's recommendations. Afterwards, restorations of Z100 composite with cylindrical shape (4 mm diameter x 5 mm height were made using a metallic mold to submit the samples to shear bond testing on an Instron universal testing machine, at a crosshead speed of 0.5 mm/min. The data were submitted to ANOVA and Tukey's test (5%. In enamel, there was no statistical difference between bovine and human teeth for SBMP (7.36 MPa, human; 8.24 MPa, bovine, nor for CLB2V (10.01 MPa, human; 7.95, bovine. In dentin, SBMP showed a statistically lower mean on human dentin (7.01 MPa than on bovine dentin (11.74 MPa. For CLB2V, there was no statistical difference between human (7.43 MPa and bovine (9.27 MPa substrates.

  5. A Randomized Comparative Study Evaluating Various Cough Stress Tests and 24-Hour Pad Test with Urodynamics in the Diagnosis of Stress Urinary Incontinence.

    Science.gov (United States)

    Henderson, Joseph W; Kane, Sarah M; Mangel, Jeffrey M; Kikano, Elias G; Garibay, Jorge A; Pollard, Robert R; Mahajan, Sangeeta T; Debanne, Sara M; Hijaz, Adonis K

    2018-06-01

    The cough stress test is a common and accepted tool to evaluate stress urinary incontinence but there is no agreement on how the test should be performed. We assessed the diagnostic ability of different cough stress tests performed when varying patient position and bladder volume using urodynamic stress urinary incontinence as the gold standard. The 24-hour pad test was also evaluated. We recruited women who presented to specialty outpatient clinics with the complaint of urinary incontinence and who were recommended to undergo urodynamic testing. A total of 140 patients were randomized to 4 cough stress test groups, including group 1-a comfortably full bladder, group 2-an empty bladder, group 3- a bladder infused with 200 cc saline and group 4-a bladder filled to half functional capacity. The sequence of standing and sitting was randomly assigned. The groups were compared by 1-way ANOVA or the generalized Fisher exact test. The κ statistic was used to evaluate agreement between the sitting and standing positions. The 95% CIs of sensitivity and specificity were calculated using the Wilson method. ROC analysis was done to evaluate the performance of the 24-hour pad test. The cough stress test performed with a bladder filled to half functional capacity was the best performing test with 83% sensitivity and 90% specificity. There was no statistically significant evidence that the sensitivity or specificity of 1 cough stress test differed from that of the others. The pad test had no significant predictive ability to diagnose urodynamic stress urinary incontinence (AUC 0.60, p = 0.08). Cough stress tests were accurate to diagnose urodynamic stress urinary incontinence. The 24-hour pad test was not predictive of urodynamic stress urinary incontinence and not helpful when used in conjunction with the cough stress test. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Combined comparative and chemical proteomics on the mechanisms of levo-tetrahydropalmatine-induced antinociception in the formalin test.

    Science.gov (United States)

    Wang, Chen; Zhou, Jiangrui; Wang, Shuowen; Ye, Mingliang; Jiang, Chunlei; Fan, Guorong; Zou, Hanfa

    2010-06-04

    This study investigated the mechanisms involved in the antinociceptive action induced by levo-tetrahydropalmatine (l-THP) in the formalin test by combined comparative and chemical proteomics. Rats were pretreated with l-THP by the oral route (40 mg/kg) 1 h before formalin injection. The antinociceptive effect of l-THP was shown in the first and second phases of the formalin test. To address the mechanisms by which l-THP inhibits formalin-induced nociception in rats, the combined comparative and chemical proteomics were applied. A novel high-throughput comparative proteomic approach based on 2D-nano-LC-MS/MS was applied to simultaneously evaluate the deregulated proteins involved in the response of l-THP treatment in formalin-induced pain rats. Thousands of proteins were identified, among which 17 proteins survived the stringent filter criteria and were further included for functional discussion. Two proteins (Neurabin-1 and Calcium-dependent secretion activator 1) were randomly selected, and their expression levels were further confirmed by Western Blots. The results matched well with those of proteomics. In the present study, we also described the development and application of l-THP immobilized beads to bind the targets. Following incubation with cellular lysates, the proteome interacting with the fixed l-THP was identified. The results of comparative and chemical proteomics were quite complementary. Although the precise roles of these identified moleculars in l-THP-induced antinociception need further study, the combined results indicated that proteins associated with signal transduction, vesicular trafficking and neurotransmitter release, energy metabolism, and ion transport play important roles in l-THP-induced antinociception in the formalin test.

  7. Comparing the executive function of patients with schizophrenia, acute/chronic type I disorder (manic episode, and healthy controls on Wisconsin Card Sorting Test and Continuous Performance Test

    Directory of Open Access Journals (Sweden)

    Hossein Zare

    2017-05-01

    Full Text Available Introduction: From among various cognitive deficits, deficits in executive processes have an effective role in limiting the patients’ ability to retain, acquire, and re-learn the skills necessary for real-life performance. Thus, the present study aimed to compare the executive function of patients with schizophrenia, acute/chronic type I disorder, and the healthy group. Methods: The present research was an analytical-comparative study. The statistical population consisted of all the outpatients and inpatients with acute/chronic schizophrenia and acute/chronic type I disorder (manic episode visiting Shafa Psychiatric Hospital, Rasht, Iran. Using convenience sampling, 60 male subjects aging 18-49 years old were selected in 2014-2015. They were matched for the variables of sex, age, and education level. The Wisconsin Card Sorting Test, Continuous Performance Test, and Raven’s Progressive Matrices were administered, and the data were analyzed using MANOVA and Tukey post-hoc test. Results: A significant difference was observed between the acute/chronic schizophrenia group, acute/chronic type I disorder (manic episode, and healthy group on the two tests. Patients with schizophrenia had a weaker executive function and attention deficit compared to those with type I disorder and the healthy group (P0.05. Conclusion: Both schizophrenia and type I disorder patients show deficits in executive function and attention. However, the former group manifests higher impairment in cognitive activities, concept formation, cognitive flexibility, and attention deficit.

  8. Manipulator Comparative Testing Program: Final report

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Sundstrom, E.; Herndon, J.N; Fujita, Y.; Maeda, M.

    1987-02-01

    The manipulator systems tested included the Meidensha BILARM 83A, the Central Research Laboratories Model M-2, and the GCA PaR Systems Model 6000. Six manipulator and control mode combinations were evaluated: (1) the BILARM in master/slave mode without force reflection, (2) the BILARM in master/slave mode with force reflection, (3) the Model M-2 in master/slave mode without force reflection, (4) the Model M-2 in master/slave mode with force reflection, (5) the BILARM with switchbox controls, and (6) the PaR 6000 with switchbox controls. The experiments examined differences between master/slave systems with and without force reflection and differences between master/slave systems and switchbox-controlled systems. A fourth experiment examined the relative contributions of the remote viewing system and the manipulator system to the performance of remote handling tasks. Results of the experiments showed that operators using the Model M-2 in master/slave mode had significantly faster times to completion than operators using the BILARM in master/slave mode, with about the same error rate per trial. Operators were slower using the BILARM with force reflection than without it, and they committed more errors. There was no statistically significant difference between force-reflection and nonforce-reflection conditions for the M-2 manipulator for any of the performance criteria. Tasks and procedures used in this testing were not sensitive to differences within any single system. No inferences about the effect of force reflection on remote task performance should be made from these data. The two manipulator systems in switchbox mode had significantly slower times to completion than any system in master/slave mode, with approximately the same error rate per trial. There were no significant differences between the BILARM in switchbox mode and the PaR arm

  9. Multiplex molecular testing for management of infectious gastroenteritis in a hospital setting: a comparative diagnostic and clinical utility study.

    Science.gov (United States)

    Halligan, E; Edgeworth, J; Bisnauthsing, K; Bible, J; Cliff, P; Aarons, E; Klein, J; Patel, A; Goldenberg, S

    2014-08-01

    Laboratory diagnosis and clinical management of inpatients with diarrhoea is complex and time consuming. Tests are often requested sequentially and undertaken in different laboratories. This causes prolonged unnecessary presumptive isolation of patients, because most cases are non-infectious. A molecular multiplex test (Luminex(®) Gastrointestinal Pathogen Panel (GPP)) was compared with conventional testing over 8 months to determine diagnostic accuracy, turnaround times, laboratory costs, use of isolation facilities and user acceptability. A total of 262 (12%) patients had a pathogen detected by conventional methods compared with 483 (22.1%) by GPP. Most additional cases were detected in patients developing symptoms in the first 4 days of admission. Additional cases were detected because of presumed improved diagnostic sensitivity but also because clinicians had not requested the correct pathogen. Turnaround time (41.8 h) was faster than bacterial culture (66.5 h) and parasite investigation (66.5 h) but slower than conventional testing for Clostridium difficile (17.3 h) and viruses (27 h). The test could allow simplified requesting by clinicians and a consolidated laboratory workflow, reducing the overall number of specimens received by the laboratory. A total of 154 isolation days were saved at an estimated cost of £30 800. Consumables and labour were estimated at £150 641 compared with £63 431 for conventional testing. Multiplex molecular testing using a panel of targets allowed enhanced detection and a consolidated laboratory workflow. This is likely to be of greater benefit to cases that present within the first 4 days of hospital admission. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  10. A cost-benefit model comparing the California Milk Cell Test and Milk Electrical Resistance Test

    Directory of Open Access Journals (Sweden)

    Inge-Marie Petzer

    2013-04-01

    Full Text Available The indirect effects of mastitis treatment are often overlooked in cost-benefit analyses, but it may be beneficial for the dairy industry to consider them. The cost of mastitis treatment may increase when the duration of intra-mammary infections are prolonged due to misdiagnosis of host-adapted mastitis. Laboratory diagnosis of mastitis can be costly and time consuming, therefore cow-side tests such as the California Milk Cell Test (CMCT and Milk Electrical Resistance (MER need to be utilised to their full potential. The aim of this study was to determine the relative benefit of using these two tests separately and in parallel. This was done using a partial-budget analysis and a cost-benefit model to estimate the benefits and costs of each respective test and the parallel combination thereof. Quarter milk samples (n= 1860 were taken from eight different dairy herds in South Africa. Milk samples were evaluated by means of the CMCT, hand-held MER meter and cyto-microbiological laboratory analysis. After determining the most appropriate cut-off points for the two cow-side tests, the sensitivity and specificity of the CMCT (Se= 1.00, Sp= 0.66, MER (Se= 0.92, Sp= 0.62 and the tests done in parallel (Se= 1.00, Sp= 0.87 were calculated. The input data that were used for partial-budget analysis and in the cost-benefit model were based on South African figures at the time of the study, and on literature. The total estimated financial benefit of correct diagnosis of host-adapted mastitis per cow for the CMCT, MER and the tests done in parallel was R898.73, R518.70 and R1064.67 respectively. This involved taking the expected benefit of a correct test result per cow, the expected cost of an error per cow and the cost of the test into account. The CMCT was shown to be 11%more beneficial than the MER test, whilst using the tests in parallel was shown to be the most beneficial method for evaluating the mastitis-control programme. Therefore

  11. Non- or full-laxative CT colonography vs. endoscopic tests for colorectal cancer screening: A randomised survey comparing public perceptions and intentions to undergo testing

    Energy Technology Data Exchange (ETDEWEB)

    Ghanouni, Alex; Wardle, Jane; Von Wagner, Christian [University College London, Health Behaviour Research Centre, Department of Epidemiology and Public Health, London (United Kingdom); Halligan, Steve; Plumb, Andrew; Boone, Darren [University College London, Centre for Medical Imaging, London (United Kingdom)

    2014-07-15

    Compare public perceptions and intentions to undergo colorectal cancer screening tests following detailed information regarding CT colonography (CTC; after non-laxative preparation or full-laxative preparation), optical colonoscopy (OC) or flexible sigmoidoscopy (FS). A total of 3,100 invitees approaching screening age (45-54 years) were randomly allocated to receive detailed information on a single test and asked to return a questionnaire. Outcomes included perceptions of preparation and test tolerability, health benefits, sensitivity and specificity, and intention to undergo the test. Six hundred three invitees responded with valid questionnaire data. Non-laxative preparation was rated more positively than enema or full-laxative preparations [effect size (r) = 0.13 to 0.54; p < 0.0005 to 0.036]; both forms of CTC and FS were rated more positively than OC in terms of test experience (r = 0.26 to 0.28; all p-values < 0.0005). Perceptions of health benefits, sensitivity and specificity (p = 0.250 to 0.901), and intention to undergo the test (p = 0.213) did not differ between tests (n = 144-155 for each test). Despite non-laxative CTC being rated more favourably, this study did not find evidence that offering it would lead to substantially higher uptake than full-laxative CTC or other methods. However, this study was limited by a lower than anticipated response rate. (orig.)

  12. Comparative performance of five Mexican plancha-type cookstoves using water boiling tests

    Directory of Open Access Journals (Sweden)

    Paulo Medina

    Full Text Available While plancha-type cookstoves are very popular and widely disseminated in Latin America, few peer review articles exist documenting their detailed technical performance. In this paper we use the standard Water Boiling Tests (WBT to assess the energy and emission performance of five plancha-type cookstoves disseminated in about 450 thousand Mexican rural homes compared to the traditional 3-stone fire (TSF. In the high-power phase, average modified combustion efficiencies (MCE for plancha-type stoves were 97±1% which was higher than TSF 93±4%, and reductions in CO and PM2.5 total emissions were on average 44%. Time to boil and specific fuel consumption, however, were increased in plancha-type stoves compared to the open fire as a result of the reduced overall thermal efficiency of the plancha during WBT. In the simmering phase, plancha-type stoves showed much more consistent performance reductions compared to the TSF. MCE for plancha stoves were on average 98±1% and 95±3% for the TSF, while reductions in CO and PM2.5 total emissions were on average 55%. In this phase 27% average savings in fuel use are achieved by plancha-type stoves. Removal of the plancha rings resulted in savings of specific fuel consumption (SFC, thermal efficiency (TE, and time to boil; however, CO and PM2.5 emissions increased significantly as flue air is drawn through the comal surface rather than through the combustion zone, resulting in suboptimal combustion conditions.International Workshop Agreement (IWA energy performance Tiers for plancha-type stoves ranged from 0 to 1. However, these results contrast sharply with the well documented reductions in fuel consumption during daily cooking activities achieved by these stoves. IWA indoor emissions Tiers are 4 for both PM2.5 and CO using locally measured values for fugitive emissions. Optimization of combustion chamber design on these stoves in Mexico is desirable to further reduce indoor emissions and to reduce the

  13. Comparable radioimmunological investigations for determination of proteohormones with test combinations

    Energy Technology Data Exchange (ETDEWEB)

    Nocke-Finck, L; von Burgsdorff, H H; Breuer, H; Geiger, W

    1976-01-01

    Some of the values obtained by different test combinations in the same experiment show considerable differences; these are mainly due to the qualitative differences of antibodies and their attenuations. The values found out in normal persons generally remain in normal regions indicated for each test combination by the producers. In determining TSH, however, the numerical values for the normal regions differ from each other, which is due to the different attributes of the methods. Special determinations of hormones in the plasma give - if any - only little information. The function of an endocrine organ can only be assessed with the help of function tests. The performance of such tests is possible by using the test combinations mentioned here.

  14. Comparative VME Performance Tests for MEN A20 Intel-L865 and RIO-3 PPC-LynxOS platforms

    CERN Document Server

    Andersen, M; CERN. Geneva. BE Department

    2009-01-01

    This benchmark note presents test results from reading values over VME using different methods and different sizes of data registers, running on two different platforms Intel-L865 and PPC-LynxOS. We find that the PowerPC is a factor 3 faster in accessing an array of contiguous VME memory locations. Block transfer and DMA read accesses are also tested and compared with conventional single access reads.

  15. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  16. Lab-scale impact test to investigate the pipe-soil interaction and comparative study to evaluate structural responses

    Directory of Open Access Journals (Sweden)

    Dong-Man Ryu

    2015-07-01

    Full Text Available This study examined the dynamic response of a subsea pipeline under an impact load to determine the effect of the seabed soil. A laboratory-scale soil-based pipeline impact test was carried out to investigate the pipeline deformation/strain as well as the interaction with the soil-pipeline. In addition, an impact test was simulated using the finite element technique, and the calculated strain was compared with the experimental results. During the simulation, the pipeline was described based on an elasto-plastic analysis, and the soil was modeled using the Mohr-Coulomb fail-ure criterion. The results obtained were compared with ASME D31.8, and the differences between the analysis results and the rules were specifically investigated. Modified ASME formulae were proposed to calculate the precise structural behavior of a subsea pipeline under an impact load when considering sand- and clay-based seabed soils.

  17. Comparative testing of slurry monitors

    International Nuclear Information System (INIS)

    Hylton, T.D.; Bayne, C.K.; Anderson, M.S.; Van Essen, D.C.

    1998-05-01

    The US Department of Energy (DOE) has millions of gallons of radioactive liquid and sludge wastes that must be retrieved from underground storage tanks, transferred to treatment facilities, and processed to a final waste form. The wastes will be removed from the current storage tanks by mobilizing the sludge wastes and mixing them with the liquid wastes to create slurries. Each slurry would then be transferred by pipeline to the desired destination. To reduce the risk of plugging a pipeline, the transport properties (e.g., density, suspended solids concentration, viscosity, particle size range) of the slurry should be determined to be within acceptable limits prior to transfer. These properties should also be monitored and controlled within specified limits while the slurry transfer is in progress. The DOE issued a call for proposals for developing on-line instrumentation to measure the transport properties of slurries. In response to the call for proposals, several researchers submitted proposals and were funded to develop slurry monitoring instruments. These newly developed DOE instruments are currently in the prototype stage. Before the instruments were installed in a radioactive application, the DOE wanted to evaluate them under nonradioactive conditions to determine if they were accurate, reliable, and dependable. The goal of this project was to test the performance of the newly developed DOE instruments along with several commercially available instruments. The baseline method for comparison utilized the results from grab-sample analyses

  18. Effect of cigarette smoking on nasal mucociliary clearance: A comparative analysis using saccharin test

    Directory of Open Access Journals (Sweden)

    Manu Kurian Baby

    2014-01-01

    Full Text Available Background: Nasal mucociliary clearance (NMC system transports the mucus layer covering the nasal epithelium towards nasopharynx by ciliary beating at a frequency of 7-16 Hz. NMC is altered by septal deviations, upper respiratory infections, and drugs. Few studies have revealed significant depression of ciliary activity in smokers. We conducted this study to compare NMC and influence duration of smoking on NMC in adult smokers and nonsmokers using saccharin test. Materials and Methods: Our study included 30 nonsmokers and 30 smokers (21-40 years who were not on any medications and had no history of any systemic illness. Time elapsing until the first experience of sweet taste at posterior nasopharynx, following placement of saccharin particle approximately 1 cm behind the anterior end of inferior turbinate was recorded as NMC time in minutes using standard method described by Anderson. Mean NMC of both groups were compared using Student′s t -test and influence of duration was analyzed by one-way Analysis of variance (ANOVA. Results: NMC was significantly prolonged in smokers (481.2 ± 29.83; P 5 years = 637.5 ± 28.49 s; F statistic = 20.8968, P = 0.0000. Conclusions: NMC measurement is a simple and useful index for the assessment of effect of smoking on the ciliary activity of respiratory mucosa. Prolonged clearance observed in smokers of our study may be due to slowed ciliary beat frequency or reduction in number of cilia and changes in viscoelastic properties of mucus.

  19. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy.

    Science.gov (United States)

    Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y

    2015-09-04

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.

  20. Comparative efficacy of several disinfectants in suspension and carrier tests against Haemophilus parasuis serovars 1 and 5.

    Science.gov (United States)

    Rodríguez Ferri, E F; Martínez, S; Frandoloso, R; Yubero, S; Gutiérrez Martín, C B

    2010-06-01

    The comparative efficacy of 16 active compounds (including the most commonly used chemical groups) and 10 commercial formulations against Haemophilus parasuis serovars 1 and 5 was studied. These organisms were tested in suspension and carrier tests in the presence and absence of serum as representative of organic matter. Chloramine-T and half of the formulations from commercial sources (most of them including quaternary ammonium compounds) were effective in both in vitro tests, regardless of the presence or absence of organic load. All 26 disinfectants except for an iodophor (0.1% available iodine) resulted in at least 3-log(10) reduction in colony-forming units in suspension test, and most of them resulted in the maximal level of detection (>6-log(10) reduction). On the other hand, disinfectants were not as effective in carrier test as in suspension test, and the presence of serum considerably reduced the activities of most of the compounds tested, especially in carrier test. These results suggest the importance of selecting suitable disinfection for routine use on surfaces contaminated with H. parasuis, particularly when organic matter is present. Chloramine-T and formulations 2 and 7-10 are recommended for a complete inactivation of H. parasuis in swine herds. Copyright 2009 Elsevier Ltd. All rights reserved.

  1. Accuracy of an Immunochromatographic Diagnostic Test (ICT Malaria Combo Cassette Test) Compared to Microscopy among under Five-Year-Old Children when Diagnosing Malaria in Equatorial Guinea

    Science.gov (United States)

    Portero, José-Luis; Rubio-Yuste, Maria; Descalzo, Miguel Angel; Raso, Jose; Lwanga, Magdalena; Obono, Jaquelina; Nseng, Gloria; Benito, Agustin; Cano, Jorge

    2010-01-01

    Conventional malaria diagnosis based on microscopy raises serious difficulties in weak health systems. Cost-effective and sensitive rapid diagnostic tests have been recently proposed as alternatives to microscopy. In Equatorial Guinea, a study was conducted to assess the reliability of a rapid diagnostic test compared to microscopy. The study was designed in accordance with the directives of the Standards for Reporting Diagnostic Accuracy Initiative (STARD). Peripheral thick and thin films for the microscopy diagnosis and a rapid immunochromatographic test (ICT Malaria Combo Cassette Test) were performed on under five-year-old children with malaria suspicion. The ICT test detected Plasmodium spp. infection with a sensitivity of 81.5% and a specificity of 81.9% while P. falciparum diagnosis occurred with a sensitivity of 69.7% and a specificity of 73.7%. The sensitivity of the ICT test increased with higher parasitemias. The general results showed little concordance between the ICT test and microscopy (kappa = 0.28, se: 0.04). In Equatorial Guinea, the ICT Malaria Combo Cassette Test has proven to be an acceptable test to detect high P. falciparum parasitemias. However, the decrease of sensitivity at medium and low parasitemias hampers that ICT can replace properly performed microscopy at present in the diagnosis of malaria in children. PMID:22332024

  2. Cardiorespiratory performance of coronary artery disease patients on land versus underwater treadmill tests: a comparative study.

    Science.gov (United States)

    Garcia, Mauricio Koprowski; Rizzo, Limanara; Yazbek-Júnior, Paulo; Yutiyama, Daniela; Silva, Fabiola Jomar da; Matheus, Denise; Mastrocolla, Luiz Eduardo; Massad, Eduardo

    2017-11-01

    To compare responses to a cardiopulmonary exercise test on land versus on an underwater treadmill, to assess the cardiorespiratory performance of coronary artery disease patients while immersed in warm water and to compare with the performance of healthy individuals. The sample population consisted of 40 subjects, which included 20 coronary artery disease patients aged 63.7±8.89 years old, functional class I and II, according to the New York Hearth Association, and 20 healthy subjects aged 64.7±7.09 years old. The statistical significances were calculated through an ANOVA test with a (1 - β) power of 0.861. ClinicalTrials.gov: NCT00989248 (22). Significant differences were uncovered in coronary artery disease group regarding the variables heart beats (HB), (p>0.01), oxygen consumption (VO2), (p>0.01) and carbon dioxide production (VCO2) (p<0.01). Also, for the same group, in relation to the environment, water versus on land for HB, VO2, VCO2 and oxygen for each heart beat (VO2/HB) all of than (p<0.01). The stages for data collected featured the subject's performance throughout the experiment, and within the given context, variables rating of perceived exertion (RPE), HB, VO2, VCO2 and VO2/HB (p<0.01) showed significant interactions between test stages and environment. Additionally, there was a significant interaction between the etiology and the test stages for the variables HB, VO2 and VCO2 (p<0.01). Electrocardiographic changes compatible with myocardial ischemia or arrhythmia were not observed. The subjects exhibited lower scores on Borg's perceived exertion scale in the water than at every one of the test stages on land (p<0.01). This study show that a cardiopulmonary exercise test can be safely conducted in subjects in immersion and that the procedures, resources and equipment used yielded replicable and reliable data. Significant differences observed in water versus on land allow us to conclude that coronary artery disease patients are able to do physical

  3. Cardiorespiratory performance of coronary artery disease patients on land versus underwater treadmill tests: a comparative study

    Directory of Open Access Journals (Sweden)

    Mauricio Koprowski Garcia

    Full Text Available OBJECTIVE: To compare responses to a cardiopulmonary exercise test on land versus on an underwater treadmill, to assess the cardiorespiratory performance of coronary artery disease patients while immersed in warm water and to compare with the performance of healthy individuals. METHODS: The sample population consisted of 40 subjects, which included 20 coronary artery disease patients aged 63.7±8.89 years old, functional class I and II, according to the New York Hearth Association, and 20 healthy subjects aged 64.7±7.09 years old. The statistical significances were calculated through an ANOVA test with a (1 - β power of 0.861. ClinicalTrials.gov: NCT00989248 (22. RESULTS: Significant differences were uncovered in coronary artery disease group regarding the variables heart beats (HB, (p>0.01, oxygen consumption (VO2, (p>0.01 and carbon dioxide production (VCO2 (p<0.01. Also, for the same group, in relation to the environment, water versus on land for HB, VO2, VCO2 and oxygen for each heart beat (VO2/HB all of than (p<0.01. The stages for data collected featured the subject’s performance throughout the experiment, and within the given context, variables rating of perceived exertion (RPE, HB, VO2, VCO2 and VO2/HB (p<0.01 showed significant interactions between test stages and environment. Additionally, there was a significant interaction between the etiology and the test stages for the variables HB, VO2 and VCO2 (p<0.01. Electrocardiographic changes compatible with myocardial ischemia or arrhythmia were not observed. The subjects exhibited lower scores on Borg’s perceived exertion scale in the water than at every one of the test stages on land (p<0.01. CONCLUSION: This study show that a cardiopulmonary exercise test can be safely conducted in subjects in immersion and that the procedures, resources and equipment used yielded replicable and reliable data. Significant differences observed in water versus on land allow us to conclude that

  4. Comparative Erythrocytes Osmotic Fragility Test and some ...

    African Journals Online (AJOL)

    Erythrocytes osmotic fragility and haematological parameters of subjects with HbAS (sickle cell trait) and HbSS (sickle cell anaemia) were determined and compared with subjects with HbAA (normal adult haemoglobin), which acted as control. They were divided into three groups of 40 subjects for HbAA, 35 subjects for ...

  5. COMPARATIVE EFFICIENCY OF SOME INDIRECT DIAGNOSTIC TESTS FOR THE DETECTION OF SUB-CLINICAL MASTITIS IN COWS AND BUFFALOES

    Directory of Open Access Journals (Sweden)

    M. IQBAL, M. AMJED1, M. A. KHAN, M. S. QURESHI1 AND U. SADIQUE1

    2006-04-01

    Full Text Available The present study was undertaken to compare five laboratory diagnostic tests for sub-clinical mastitis in cattle and buffaloes and to compute cost, time taken by each test and its ranking for availability, adoptability, interpretability and sensitivity. There were 352 cases with each test type viz. California Mastitis Test (CMT, White Side Test (WST, White Side + Dye (WSTD, Surf Test and Surf + Dye, and 880 cases with each species type (cattle and buffaloes. Result scores (1760 for sub-clinical mastitis in each category of negative, trace, single positive, double positive and triple positive by species, and laboratory tests, were analyzed using nonparametric tests. Chi-square statistics showed that CMT was equally effective at both locations (farm vs. laboratory. Correlation further suggested that the association was highly significant. Moreover, cases in category of negative, trace and single positive strongly differed (P0.05. The study further suggested that CMT was the most sensitive test, followed by WST/WSTD and Surf/Surf + Dye. Although, the five tests showed slight discrepancy in the trace category reaction, a strong relationship of Surf Test to CMT, its low cost, easy availability and readily adoptable qualities should spur the relevant authorities to recommend the use of Surf test as a routine practice in dairy farming and add this test in the curriculum of diploma and degree programmes.

  6. Statistical comparative study on a combined radioiodine test and extended protirelin test and correlation with the common in vitro parameters of hyroid function

    International Nuclear Information System (INIS)

    Kraemer, H.A.

    1982-01-01

    Using the data of 339 patients, the following parameters of thyroid function were statistically evaluated. The in vitro parameters ET 3 U, TT 4 (D), FT 4 -index and PB 127 I and the radioiodine test with determination of PB 131 I before i.v. injection of 400 μg protirelin (DHP) and 120 minutes after the injection. There was no correlation between the percentage Change of the PB 121 I level 120 min after protirelin (DHP) administration and the percentage change of the TSH level 30 min after protirelin (DTP1) administration. The accuracies of the in vitro parameters ET 3 U, TT 4 (D) and FT 4 -index on the one hand and the extended protirelin test on the other hand were compared. (orig./MG) [de

  7. Comparative evaluation of pyrogens tests in pharmaceutical products Avaliação comparativa de testes de pirogênios em produtos farmacêuticos

    Directory of Open Access Journals (Sweden)

    Rosimar L. Silveira

    2004-06-01

    Full Text Available A comparison of methodologies for detection of pyrogens in pharmaceutical products was performed. The rabbit pyrogen test was optimized and the dose-response curve was obtained for the 2nd International Standard for bacterial endotoxins, establishing 13.81 EU/mL/kg as the concentration of endotoxin necessary to induce a temperature rise of 0.5ºC. The 0.5ºC cut-off was shown to give results that were more compatible with the pyrogenic doses for humans. The Limulus amoebocyte lysate test (LAL was standardized with gel-clot and chromogenic endpoints, and used for the comparative evaluation of pharmaceutical products showing good agreement. The use of beta-glucan-reactive and non-reactive LAL reagents identified some products with false-positive results. The interference test was carried out and the specifications validated for some new products as the maximum valid dilution. The results emphasized the importance and limitations of the assays recommended for the evaluation of purity and quality control of parenteral medicinal products, improving the existing methodologies in the context of reduction and replacement in the use of animal models.Realizou-se a comparação de metodologia para avaliação de pirogênios em produtos farmacêuticos. Otimizou-se o teste da hipertermia em coelhos elaborando a curva dose-resposta com o 2º Padrão Internacional de endotoxinas bacterianas, com base na qual determinou-se a concentração de 13,81 UE/mL por kg de peso corporal, necessária para produzir aumento de temperatura de 0,5ºC. Observou-se que o limite de 0,5ºC forneceu resultados comparáveis com as doses pirogênicas para o homem. Padronizou-se o teste do lisado de amebócitos do Limulus (LAL com determinação do ponto final cromogênico e por geleificação, que foram utilizados para a avaliação de produtos farmacêuticos obtendo-se resultados concordantes. Avaliaram-se as respostas de reagentes LAL reativos e não-reativos a beta

  8. Comparative assay of fluorescent antibody test results among twelve European National Reference Laboratories using various anti-rabies conjugates

    DEFF Research Database (Denmark)

    Robardet, E.; Andrieu, S.; Rasmussen, Thomas Bruun

    2013-01-01

    Twelve National Reference Laboratories (NRLs) for rabies have undertaken a comparative assay to assess the comparison of fluorescent antibody test (FAT) results using five coded commercial anti-rabies conjugates (Biorad, Bioveta, Fujirebio, Millipore, and SIFIN conjugates). Homogenized positive...

  9. Panel Unit Root Tests by Combining Dependent Values: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Xuguang Sheng

    2011-01-01

    Full Text Available We conduct a systematic comparison of the performance of four commonly used value combination methods applied to panel unit root tests: the original Fisher test, the modified inverse normal method, Simes test, and the modified truncated product method (TPM. Our simulation results show that under cross-section dependence the original Fisher test is severely oversized, but the other three tests exhibit good size properties. Simes test is powerful when the total evidence against the joint null hypothesis is concentrated in one or very few of the tests being combined, but the modified inverse normal method and the modified TPM have good performance when evidence against the joint null is spread among more than a small fraction of the panel units. These differences are further illustrated through one empirical example on testing purchasing power parity using a panel of OECD quarterly real exchange rates.

  10. A comparative study of Mono Mac 6 cells, isolated mononuclear cells and Limulus amoebocyte lysate assay in pyrogen testing

    DEFF Research Database (Denmark)

    Moesby, Lise; Jensen, S; Hansen, E W

    1999-01-01

    ) and Staphylococcus aureus was comparable to that of MNC. Aspergillus niger and Candida albicans induced IL-6 in isolated MNC, but not in MM6. The detection limit for Salmonella typhimurium in the MM6 assay was comparable to that of the LAL assay. As expected, S. aureus and C. albicans did not show any LAL activity......Pyrogen induced secretion of interleukin 6 (IL-6) in Mono Mac 6 (MM6) cells was measured. The ability of the MM6 cell culture to detect pyrogens was compared to the Limulus amoebocyte lysate (LAL) test and isolated mononuclear cells (MNC). The detection limit of MM6 for lipopolysaccharide (LPS....... A. niger and Influenza virus showed some activity in the LAL test, but could not be detected by MM6 cells. In conclusion, the MM6 assay is a good supplement to the current pyrogen assays for detection of LPS, S. aureus and S. typhimurium, but the MM6 assay could not detect A. niger, C. albicans...

  11. Parâmetros psicométricos: estudo comparativo entre testes de inteligência e de personalidade Psychometric parameters: comparative study between intelligence and personality tests

    Directory of Open Access Journals (Sweden)

    Ana Paula Porto Noronha

    2003-01-01

    Full Text Available A validade e a precisão de testes psicológicos vêm sendo bastante questionadas e discutidas atualmente. O presente estudo teve como objetivo avaliar a validade, a precisão e a existência de padronização brasileira em 43 testes psicológicos comercializados no Brasil, sendo 22 de inteligência e 21 de personalidade. Os testes foram comparados quanto ao período de publicação no Brasil. Os resultados indicaram que existe maior número de instrumentos publicados nas décadas de 1980 e 1990, que os testes de inteligência apresentam mais estudos de padronização, validade e precisão, embora não tenha havido diferença significante entre os grupos de testes (inteligência e personalidade. Novos estudos devem ser desenvolvidos com o intuito de promover os testes psicológicos e a área de avaliação psicológica, como um todo.Nowadays, the validity and the reliability of psychological tests are being very questioned and discussed. The current study aims to evaluate the validity, the reliability and the existence of Brazilian standardization in 43 psychological tests commercialized in Brazil, being 22 of intelligence and 21 of personality. The tests have been compared concearning the publication period in Brazil. The results have indicated that there is a bigger number of instruments published in the 1980´s and 1990´s, that the intelligence tests present more studies of standardization, validity and reliability, even though there hasn´t been significant difference among the groups tests (intelligence and personality. New studies must be developed aiming to promote the psychological tests and the area of psychological assessment, as a whole.

  12. Outpatient versus inpatient mixed meal tolerance and arginine stimulation testing yields comparable measures of variability for assessment of beta cell function

    Directory of Open Access Journals (Sweden)

    Sudha S. Shankar

    2018-06-01

    Full Text Available Standard practice to minimize variability in beta cell function (BCF measurement is to test in inpatient (IP settings. IP testing strains trial subjects, investigators, and budgets. Outpatient (OP testing may be a solution although there are few reports on OP BCF testing variability. We compared variability metrics between OP and IP from a standardized mixed meal tolerance test (MMTT and arginine stimulation test (AST in two separate type 2 diabetes (T2DM cohorts (OP, n = 20; IP n = 22 in test-retest design. MMTT variables included: insulin sensitivity (Si; beta cell responsivity (Φtot; and disposition index (DItot = Si* Φtot following 470 kCal meal. AST variables included: acute insulin response to arginine (AIRarg and during hyperglycemia (AIRargMAX. Results: Baseline characteristics were well-matched. Between and within subject variance for each parameter across cohorts, and intraclass correlation coefficients (ICC-a measure of reproducibility across parameters were generally comparable for OP to IP. Table summarizes the ICC results for each key parameter and cohort.Test/ParameterOutpatient (95% CIInpatient (95% CIMMTT: Si0.49(0,0.690.28(0,0.60MMTT: Φtot0.65(0.16,0.890.81(0.44,0.93MMTT: DI0.67(0,0.830.36(0,0.69AST: AIR Arg0.96(0.88,0.980.84(0.59,0.94AST: AIR Arg Max0.97(0.90,0.990.95(0.86,0.97AST: ISR0.93(0.77,0.970.93(0.82,0.96In conclusion, the variability (reproducibility of BCF measures from standardized MMTT and AST is comparable between OP and IP settings. These observations have significant implications for complexity and cost of metabolic studies.

  13. Sugar and protein digestion in flowerpiercers and hummingbirds: a comparative test of adaptive convergence.

    Science.gov (United States)

    Schondube, J E; Martinez del Rio, C

    2004-04-01

    Flowerpiercers are the most specialized nectar-feeding passerines in the Neotropics. They are nectar robbers that feed on the sucrose-rich diet of hummingbirds. To test the hypothesis that flowerpiercers have converged with hummingbirds in digestive traits, we compared the activity of intestinal enzymes and the gut nominal area of cinnamon-bellied flowerpiercers (Diglossa baritula) with those of eleven hummingbird species. We measured sucrase, maltase, and aminopeptidase-N activities. To provide a comparative context, we also compared flowerpiercers and hummingbirds with 29 species of passerines. We analyzed enzyme activity using both standard allometric analyses and phylogenetically independent contrasts. Both approaches revealed the same patterns. With the exception of sucrase activity, hummingbirds' digestive traits were indistinguishable from those of passerines. Sucrase activity was ten times higher in hummingbirds than in passerines. Hummingbirds and passerines also differed in the relationship between intestinal maltase and sucrase activities. Maltase activity was two times higher per unit of sucrase activity in passerines than in hummingbirds. The sucrase activity of D. baritula was much lower than that of hummingbirds, and not unlike that expected for a passerine of its body mass. With the exception of aminopeptidase-N activity, the digestive traits of D. baritula were not different from those of other passerines. Copyright 2004 Springer-Verlag

  14. Comparing Science Virtual and Paper-Based Test to Measure Students’ Critical Thinking based on VAK Learning Style Model

    Science.gov (United States)

    Rosyidah, T. H.; Firman, H.; Rusyati, L.

    2017-02-01

    This research was comparing virtual and paper-based test to measure students’ critical thinking based on VAK (Visual-Auditory-Kynesthetic) learning style model. Quasi experiment method with one group post-test only design is applied in this research in order to analyze the data. There was 40 eight grade students at one of public junior high school in Bandung becoming the sample in this research. The quantitative data was obtained through 26 questions about living thing and environment sustainability which is constructed based on the eight elements of critical thinking and be provided in the form of virtual and paper-based test. Based on analysis of the result, it is shown that within visual, auditory, and kinesthetic were not significantly difference in virtual and paper-based test. Besides, all result was supported by quistionnaire about students’ respond on virtual test which shows 3.47 in the scale of 4. Means that student showed positive respond in all aspet measured, which are interest, impression, and expectation.

  15. Combining situated Cognitive Engineering with a novel testing method in a case study comparing two infusion pump interfaces

    NARCIS (Netherlands)

    Schnittker, R.; Schmettow, M.; Verhoeven, F.; Schraagen, J.M.C.

    2016-01-01

    We validated the usability of a new infusion pump interface designed with a situated Cognitive Engineering approach by comparing it to a reference interface using a novel testing method employing repeated measurements and process measures, in addition to traditional outcome measures. The sample

  16. Comparing word and face recognition

    DEFF Research Database (Denmark)

    Robotham, Ro Julia; Starrfelt, Randi

    2017-01-01

    included, as a control, which makes designing experiments all the more challenging. Three main strategies have been used to overcome this problem, each of which has limitations: 1) Compare performances on typical tests of the three stimulus types (e.g., a Face Memory Test, an Object recognition test...... this framework to classify tests and experiments aiming to compare processing across these categories, it becomes apparent that core differences in characteristics (visual and semantic) between the stimuli make the problem of designing comparable tests an insoluble conundrum. By analyzing the experimental...

  17. Evaluating the Comparability of PPT and CBT by Implementing the Compulsory Islamic Culture Course Test in Jordan University

    Directory of Open Access Journals (Sweden)

    Abdelnaser Sanad Alakyleh

    2017-12-01

    Full Text Available Study aims to determine whether the university students' scores in the compulsory Islamic culture course test on a selected sample differ across the paper-and pencil test (PPT & computer-based test (CBT versions, and to reveal the relationship between gender and the student's level of performance in the test. Therefore, the study evaluated the comparability of two versions of a compulsory Islamic culture course test (PPTs and (CBTs. The importance of conducting the study in Jordan stems from the fact that public and private universities have begun to move away from the traditional patterns of tests such (PPTs and went towards (CBTs. In addition to detecting which model gives the best in the output and has the characteristics of the psychometric test, furthermore, indicates whether there were any differences between males and females, the study sample consisted of 120 individuals, 67 females and 53 males from scientific, health and humanities colleges. The results showed that there was no significant difference between the two versions provided to students CBT and PPT with 0.36 moderate correlation indicators in the pre-CBT test, no significant differences between the males and females in the CBT test results. Therefore, on the basis of the results of the present study, the CBT test is an option and a preferred alternative for regular students of the bachelor's level at the University of Jordan.

  18. Physical Attributes and NFL Combine Performance Tests Between Italian National League and American Football Players: A Comparative Study.

    Science.gov (United States)

    Vitale, Jacopo A; Caumo, Andrea; Roveda, Eliana; Montaruli, Angela; La Torre, Antonio; Battaglini, Claudio L; Carandente, Franca

    2016-10-01

    Vitale, JA, Caumo, A, Roveda, E, Montaruli, A, La Torre, A, Battaglini, CL, and Carandente, F. Physical attributes and NFL Combine performance tests between Italian National League and American football players: a comparative study. J Strength Cond Res 30(10): 2802-2808, 2016-The purpose of this study was to examine anthropometric measurements and the results of a battery of performance tests administered during the National Football League (NFL) Combine between American football players who were declared eligible to participate in the NFL Combine and football players of a top Italian team (Rhinos Milan). Participants (N = 50) were categorized by position into 1 of 3 groups based on playing position: skill players (SP) included wide receivers, cornerbacks, free safeties, strong safeties, and running backs; big skill players (BSP) consisted of fullbacks, linebackers, tight ends, and defensive ends; lineman (LM) included centers, offensive guards, offensive tackles, and defensive tackles. A 1-way analysis of variance followed by the Tukey-Kramer post hoc test was used for comparisons between Italian players by playing position. Ninety-five percent CIs were used for comparisons between American and Italian football for the NFL Combine performance tests. Significant differences for all the variables between the 3 playing categories were observed among the Italian players; LM had higher anthropometric and body composition values than SP (p football players presented significantly higher anthropometric values and test performance scores when compared with Italian players. Administrators of professional football teams in Italy need to improve the player's physical attributes, so the gap that currently exists between American and Italian players can be reduced, which could significantly improve the quality of American football in Italy.

  19. Methodological approaches to conducting pilot and proof tests on reverse-osmosis systems: Results of comparative studies

    Science.gov (United States)

    Panteleev, A. A.; Bobinkin, V. V.; Larionov, S. Yu.; Ryabchikov, B. E.; Smirnov, V. B.; Shapovalov, D. A.

    2017-10-01

    When designing large-scale water-treatment plants based on reverse-osmosis systems, it is proposed to conduct experimental-industrial or pilot tests for validated simulation of the operation of the equipment. It is shown that such tests allow establishing efficient operating conditions and characteristics of the plant under design. It is proposed to conduct pilot tests of the reverse-osmosis systems on pilot membrane plants (PMPs) and test membrane plants (TMPs). The results of a comparative experimental study of pilot and test membrane plants are exemplified by simulating the operating parameters of the membrane elements of an industrial plant. It is concluded that the reliability of the data obtained on the TMP may not be sufficient to design industrial water-treatment plants, while the PMPs are capable of providing reliable data that can be used for full-scale simulation of the operation of industrial reverse-osmosis systems. The test membrane plants allow simulation of the operating conditions of individual industrial plant systems; therefore, potential areas of their application are shown. A method for numerical calculation and experimental determination of the true selectivity and the salt passage are proposed. An expression has been derived that describes the functional dependence between the observed and true salt passage. The results of the experiments conducted on a test membrane plant to determine the true value of the salt passage of a reverse-osmosis membrane are exemplified by magnesium sulfate solution at different initial operating parameters. It is shown that the initial content of a particular solution component has a significant effect on the change in the true salt passage of the membrane.

  20. A Comparative Risk Assessment of Extended Integrated Leak Rate Testing Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ji Yong; Hwang, Seok Won; Lee, Byung Sik [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2009-10-15

    This paper presents the risk impacts of extending the Integrated Leak Rate Testing (ILRT) intervals (from five years to ten years) of Yonggwang (YGN) Unit 1 and 2. These risk impacts depended on the annual variances of meteorological data and resident population. Main comparisons were performed between the initial risk assessment (2005) for the purpose of extending ILRT interval and risk reassessment (2009) where the changed plant internal configurations (core inventory and radioisotope release fraction) and plant external alterations (wind directions, rainfall and population distributions) were monitored. The reassessment showed that there was imperceptible risk increase when the ILRT interval was extended compared to the initial risk assessment. In addition, the increased value of the Large Early Release Frequency (LERF) also satisfied the acceptance guideline proposed on Reg. Guide 1.174. The MACCS II code was used for evaluating the offsite consequence analysis. The primary risk index were used as the Probabilistic Population Dose (PPD) by considering the early effects within 80 km. The Probabilistic Safety Assessment (PSA) of YGN 1 and 2 was applied to evaluate the accident frequency of each source term category and the used PSA scope was limited to internal event.

  1. Efficient statistical tests to compare Youden index: accounting for contingency correlation.

    Science.gov (United States)

    Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan

    2015-04-30

    Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.

  2. An economic evaluation of preclinical testing strategies compared to the compulsory scrapie flock scheme in the control of classical scrapie.

    Directory of Open Access Journals (Sweden)

    Lisa Boden

    Full Text Available Cost-benefit is rarely combined with nonlinear dynamic models when evaluating control options for infectious diseases. The current strategy for scrapie in Great Britain requires that all genetically susceptible livestock in affected flocks be culled (Compulsory Scrapie Flock Scheme or CSFS. However, this results in the removal of many healthy sheep, and a recently developed pre-clinical test for scrapie now offers a strategy based on disease detection. We explore the flock level cost-effectiveness of scrapie control using a deterministic transmission model and industry estimates of costs associated with genotype testing, pre-clinical tests and the value of a sheep culled. Benefit was measured in terms of the reduction in the number of infected sheep sold on, compared to a baseline strategy of doing nothing, using Incremental Cost Effectiveness analysis to compare across strategies. As market data was not available for pre-clinical testing, a threshold analysis was used to set a unit-cost giving equal costs for CSFS and multiple pre-clinical testing (MT, one test each year for three consecutive years. Assuming a 40% within-flock proportion of susceptible genotypes and a test sensitivity of 90%, a single test (ST was cheaper but less effective than either the CSFS or MT strategies (30 infected-sales-averted over the lifetime of the average epidemic. The MT strategy was slightly less effective than the CSFS and would be a dominated strategy unless preclinical testing was cheaper than the threshold price of £6.28, but may be appropriate for flocks with particularly valuable livestock. Though the ST is not currently recommended, the proportion of susceptible genotypes in the national flock is likely to continue to decrease; this may eventually make it a cost-effective alternative to the MT or CSFS.

  3. A music quality rating test battery for cochlear implant users to compare the FSP and HDCIS strategies for music appreciation.

    Science.gov (United States)

    Looi, Valerie; Winter, Philip; Anderson, Ilona; Sucher, Catherine

    2011-08-01

    The purpose of this study was to develop a music quality rating test battery (MQRTB) and pilot test it by comparing appraisal ratings from cochlear implant (CI) recipients using the fine-structure processing (FSP) and high-definition continuous interleaved sampling (HDCIS) speech processing strategies. The development of the MQRTB involved three stages: (1) Selection of test items for the MQRTB; (2) Verification of its length and complexity with normally-hearing individuals; and (3) Pilot testing with CI recipients. Part 1 involved 65 adult listeners, Part 2 involved 10 normally-hearing adults, and Part 3 involved five adult MED-EL CI recipients. The MQRTB consisted of ten songs, with ratings made on scales assessing pleasantness, naturalness, richness, fullness, sharpness, and roughness. Results of the pilot study, which compared FSP and HDCIS for music, indicated that acclimatization to a strategy had a significant effect on ratings (p genre on ratings. Overall the results suggest that the use of FSP as the default strategy for MED-EL recipients would have a positive effect on music appreciation, and that the MQRTB is an effective tool for assessing music sound quality.

  4. Harmonization of rules for VCU testing of maize in comparable agro ecological regions

    Directory of Open Access Journals (Sweden)

    van Waes J.

    2004-01-01

    variety with the same reliability as at national level. For the future variety testing should be realized on the basis of comparable agro-ecological regions with the same crop husbandry and use of the crop. These regions must be clearly defined so that the release of varieties corresponds to the high demands for harvest security and good conservation possibilities of the harvested material. The most important criteria for evaluation should be: harvest security, disease resistance, yield and quality. The basis for a good success for international cooperation is a good knowledge of the national systems: searching for similarities and finding a solution for differences. Once a variety on a catalogue in one European country, the breeding company tries to sell the variety in the whole agro-ecological for which the variety is adapted. Therefore it is important that in the surrounding zones, where the variety is tested, the same criteria are valid. In this presentation we will give a proposal for harmonization and international cooperation for controlling the VCU- value of new maize varieties.

  5. Comparative evaluation of 131I-hippuran and sup(99m)Tc-DTPA for renal function test

    International Nuclear Information System (INIS)

    Kempi, V.; Persson, R.B.R.; Svensson, L.

    1975-07-01

    131 I-labelled Hippuran and sup(99m)Tc-labelled DTPA have been compared as substances used for renal function tests. The radiation absorbed dose for 131 I-Hippuran and sup(99m)Tc-DTPA to different organs of an adult standard man is given i a table, showing considerably lower doses for sup(99m)Tc-DTPA. Good agreement was found between the renographic curves obtained with 131 I-Hippuran and sup(99m)Tc-DTPA compared to 131 I-Hippuran excellent scintiphotos of the kidney and also of the upper urinary ways were obtained with sup(99m)Tc-DTPA. With sup(99m)Tc-DTPA, repeated examinations make it possible to follow the development of a disease without great radiation risk to the patient (K.K.)

  6. Comparative genotoxicity testing of Rhine river sediment extracts using the comet assay with permanent fish cell lines (RTG-2 and RTL-W1) and the Ames test

    Energy Technology Data Exchange (ETDEWEB)

    Kosmehl, T.; Braunbeck, T.; Hollert, H. [Dept. of Zoology, Aquatic Ecology and Toxicology Section, Univ. of Heidelberg (Germany); Krebs, F.; Manz, W. [German Federal Inst. of Hydrology, Koblenz (Germany); Erdinger, L. [Dept. for Hygiene and Medical Microbiology, Inst. for Hygiene, Univ. of Heidelberg (Germany)

    2004-07-01

    Whilst at least in Germany assessment strategies on the basis of chemical analysis and acute toxicity data dominated the last decades, the development of more specific biological endpoints and biomarkers in ecotoxicology is required in order to arrive at a good ecological potential and good chemical status of surface waters in the European river basins until the year 2015, as required by the European Water Framework Directive. Since sediments have for long been known to function both as a sink and as a source of pollutants in aquatic systems, and since part of the particle-associated substances have frequently been demonstrated to cause mutagenic and carcinogenic effects in aquatic organisms, particularly in fish, there is, among other requirements, an urgent need to develop, standardize and implement integrated vertebrate-based test systems addressing genotoxicity into recent sediment investigation strategies. Thus, the present study was designed to compare the suitability of two commonly used test systems, the comet assay and the Ames test, for the evaluation of the ecotoxicological burden of surface and core sediment samples from the river Rhine. Methods (or main features). In order to determine the importance of inherent enzymatic activities, two permanent fish cell lines with different biotransformation capacities, RTL-W1 and RTG-2, were compared with respect to their capability of detecting genotoxic effects in 18 surface and core sediment samples from 9 locations along the river Rhine in the comet assay with and without exogenous bioactivation. For further comparison, as a prokaryotic mutagenicity assay, the Salmonella plate incorporation assay (Ames test) with the test strains TA98 and TA100 with and without exogenous metabolic activation was used. Results and discussion. Whereas all sediment extracts induced genotoxic effects in the comet assay with RTL-W1 cells, only 12 out of 18 sediment extracts revealed significant genotoxicity in the tests with the

  7. Comparing Direct versus Indirect Measures of the Pedagogical Effectiveness of Team Testing

    Science.gov (United States)

    Bacon, Donald R.

    2011-01-01

    Direct measures (tests) of the pedagogical effectiveness of team testing and indirect measures (student surveys) of pedagogical effectiveness of team testing were collected in several sections of an undergraduate marketing course with varying levels of the use of team testing. The results indicate that although students perceived team testing to…

  8. The impact of Nursing Rounds on the practice environment and nurse satisfaction in intensive care: pre-test post-test comparative study.

    Science.gov (United States)

    Aitken, Leanne M; Burmeister, Elizabeth; Clayton, Samantha; Dalais, Christine; Gardner, Glenn

    2011-08-01

    Factors previously shown to influence patient care include effective decision making, team work, evidence based practice, staffing and job satisfaction. Clinical rounds have the potential to optimise these factors and impact on patient outcomes, but use of this strategy by intensive care nurses has not been reported. To determine the effect of implementing Nursing Rounds in the intensive care environment on patient care planning and nurses' perceptions of the practice environment and work satisfaction. Pre-test post-test 2 group comparative design. Two intensive care units in tertiary teaching hospitals in Australia. A convenience sample of registered nurses (n=244) working full time or part time in the participating intensive care units. Nurses in participating intensive care units were asked to complete the Practice Environment Scale-Nursing Work Index (PES-NWI) and the Nursing Worklife Satisfaction Scale (NWSS) prior to and after a 12 month period during which regular Nursing Rounds were conducted in the intervention unit. Issues raised during Nursing Rounds were described and categorised. The characteristics of the sample and scale scores were summarised with differences between pre and post scores analysed using t-tests for continuous variables and chi-square tests for categorical variables. Independent predictors of the PES-NWI were determined using multivariate linear regression. Nursing Rounds resulted in 577 changes being initiated for 171 patients reviewed; these changes related to the physical, psychological--individual, psychological--family, or professional practice aspects of care. Total PES-NWI and NWSS scores were similar before and after the study period in both participating units. The NWSS sub-scale of interaction between nurses improved in the intervention unit during the study period (pre--4.85±0.93; post--5.36±0.89, p=0.002) with no significant increase in the control group. Factors independently related to higher PES-NWI included

  9. Comparative A/B testing a mobile data acquisition app for hydrogeochemistry

    Science.gov (United States)

    Klump, Jens; Golodoniuc, Pavel; Reid, Nathan; Gray, David; Ross, Shawn

    2015-04-01

    In the context of a larger study on the Capricorn Orogen of Western Australia, the CSIRO Mineral Discovery Program is conducting a regional study of the hydrogeochemistry on water from agricultural and other bores. Over time, the sampling process was standardised and a form for capturing metadata and data from initial measurements was developed. In 2014 an extensive technology review was conducted with an aim to automate field data acquisition process. A prototype hydrogeochemistry data capture form was implemented as a mobile application for Windows Mobile devices. This version of the software was a standalone application with an interface to export data as CSV files. A second candidate version of the hydrogeochemistry data capture form was implemented as an Android mobile application in the FAIMS framework. FAIMS is a framework for mobile field data capture, originally developed by at the University of New South Wales for archaeological field data collection. A benefit of the FAIMS application was the ability to associate photographs taken with the device's embedded camera with the captured data. FAIMS also allows networked collaboration within a field team, using the mobile applications as asynchronous rich clients. The network infrastructure can be installed in the field ("FAIMS in a Box") to supply data synchronisation, backup and transfer. This aspect will be tested in the next field season. A benefit of the FAIMS application was the ability to associate photographs taken with the device's embedded camera with the captured data. Having two data capture applications available allowed us to conduct an A/B test, comparing two different implementations for the same task. Both applications were trialled in the field by different field crews and user feedback will be used to improve the usability of the app for the next field season. A key learning was that the ergonomics of the app is at paramount importance to gain the user acceptance. This extends from general

  10. A comparative study of the effect of automobile pollution on pulmonary function tests of exposed cab drivers

    Directory of Open Access Journals (Sweden)

    Amrith Pakkala

    2013-01-01

    Full Text Available Background: Urbanization is associated with an enormous increase in vehicular traffic emitting exhausts and polluting the atmosphere. Emissions from vehicular traffic constitute the most significant source of ultraparticle in an urban environment. Cab drivers who work near areas located in the vicinity of traffic junctions through which maximum number of vehicles passes are more prone to develop health issues pertaining to the respiratory system. The effect of this occupational hazard in this unorganised workforce is not adequately studied. This study is designed to determine the effect of air pollution on the pulmonary system in cab drivers exposed to automobile exhaust. Materials and Methods: This study was conducted by performing pulmonary function tests (PFTs on 20 cab drivers who are exposed to automobile exhaust by virtue of their work venue nearer to traffic junctions and comparing them with 20 age, gender-matched, and anthropometric profile cab drivers who work in a rural setting free from vehicular air pollution. PFT by computerized spirometer measuring forced vital capacity (FVC, forced expiratory volume (FEV 1 , FEV1/FVC, peak expiratory flow rate (PEFR, and forced expiratory flow (FEF 25%-75% were measured. Statistical analysis was done by Student′s t test (two-tailed, independent for intergroup analysis. Results: There was a statistically significant decline in dynamic pulmonary function parameters in the study group when compared. FVC, FEV in first second, PEFR, FEV 1 /FVC, and FEF 25%-75% were all found to be statistically significantly lower in cab drivers as compared to control group (P < 0.001. Conclusion: This study finds a significant decline in various PFT parameters recorded in the study group as compared with the control group. These suggests a tendency for obstructive lung disease among cab drivers exposed to a polluted urban environment.

  11. Comparing Postsecondary Marketing Student Performance on Computer-Based and Handwritten Essay Tests

    Science.gov (United States)

    Truell, Allen D.; Alexander, Melody W.; Davis, Rodney E.

    2004-01-01

    The purpose of this study was to determine if there were differences in postsecondary marketing student performance on essay tests based on test format (i.e., computer-based or handwritten). Specifically, the variables of performance, test completion time, and gender were explored for differences based on essay test format. Results of the study…

  12. Comparative testing of radiographic testing, ultrasonic testing and phased array advanced ultrasonic testing non destructive testing techniques in accordance with the AWS D1.5 bridge welding code.

    Science.gov (United States)

    2014-02-01

    A comprehensive body of non-destructive testing data was collected from steel bridge welds under real-world conditions in a fabricators shop. Three different non-destructive testing (NDT) techniques were used on each weld inspection, these being R...

  13. A comparative evaluation of in vitro skin sensitisation tests: the human cell-line activation test (h-CLAT) versus the local lymph node assay (LLNA).

    Science.gov (United States)

    Ashikaga, Takao; Sakaguchi, Hitoshi; Sono, Sakiko; Kosaka, Nanae; Ishikawa, Makie; Nukada, Yuko; Miyazawa, Masaaki; Ito, Yuichi; Nishiyama, Naohiro; Itagaki, Hiroshi

    2010-08-01

    We previously developed the human cell-line activation test (h-CLAT) in vitro skin sensitisation test, based on our reported finding that a 24-hour exposure of THP-1 cells (a human monocytic leukaemia cell line) to sensitisers is sufficient to induce the augmented expression of CD86 and CD54. The aim of this study is to confirm the predictive value of h-CLAT for skin sensitisation activity by employing a larger number of test chemicals. One hundred chemicals were selected, according to their categorisation in the local lymph node assay (LLNA), as being: extreme, strong, moderate and weak sensitisers, and non-sensitisers. The correlation of the h-CLAT results with the LLNA results was 84%. There were some false negatives (e.g. benzoyl peroxide, hexyl cinnamic aldehyde) and some false positives (e.g. 1-bromobutane, diethylphthalate). Eight out of the 9 false negatives (89%) were water-insoluble chemicals. The h-CLAT could positively predict not only extreme and strong sensitisers, but also moderate and weak sensitisers, though the detection rates of weak sensitisers and non-sensitisers were comparatively low. Some sensitisers enhanced both CD86 and CD54 levels, and some enhanced the level of only one of them. The use of the combination of CD86 and CD54 induction as a positive indicator, improved the accuracy of the test. In conclusion, the h-CLAT is expected to be a useful cell-based in vitro method for predicting skin sensitisation potential. 2010 FRAME.

  14. Single and repeated GnRH agonist stimulation tests compared with basal markers of ovarian reserve in the prediction of outcome in IVF

    NARCIS (Netherlands)

    Hendriks, D.J.; Broekmans, F.J.M.; Bancsi, L.F.J.M.M.; Looman, C.W.N.; Jong, F.H. de; Velde, E.R. te

    Purpose: To study the value of a single or repeated GnRH agonist stimulation test (GAST) in predicting outcome in IVF compared to basal ovarian reserve tests. Methods: A total of 57 women was included. In a cycle prior to the IVF treatment, on day 3, an antral follicle count (AFC) was performed

  15. Comparing technical proficiency of elite table tennis players with intellectual disability: simulation testing versus game play.

    Science.gov (United States)

    Van Biesen, Debbie; Mactavish, Jennifer J; Vanlandewijck, Yves C

    2014-04-01

    Technical skill proficiency among elite table tennis players with intellectual disabilities (ID) was investigated in this study using two approaches: an off-court simulation testing protocol and an on-court, standardized observational framework during game play. Participants included 24 players with ID (M age = 25 yr., SD = 6; M IQ = 61, SD = 9), the top 16 performers, 13 men and 11 women, at the International Federation for sport for para-athletes with an intellectual disability (Inas) World Championships. Self-reported table tennis training experience of the players was 13 +/- 5 yr. In the Simulation Testing condition, players were instructed to play five sets of basic and five sets of advanced skills, which were subsequently assessed by experts using a standardized and validated observational protocol. The same protocol was used to assess the same skills during Game Play. Ratings of overall technical proficiency were not significantly different between Simulation Testing and Game Play conditions. There was a strong positive correlation between technical proficiency measured during Game Play vs Simulation Testing for the variables flick, topspin forehand, and topspin backhand. No correlations were found for the variables contra, block, and push. Insight into this relationship is important for future development of classification systems for ID athletes in the Paralympic Games, because comparing competition observation with the athlete's potential shown during the classification session is essential information for classifiers to confirm the athlete's competition class.

  16. Are rapid diagnostic tests more accurate in diagnosis of plasmodium falciparum malaria compared to microscopy at rural health centres?

    Directory of Open Access Journals (Sweden)

    Magnussen Pascal

    2010-12-01

    Full Text Available Abstract Background Prompt, accurate diagnosis and treatment with artemisinin combination therapy remains vital to current malaria control. Blood film microscopy the current standard test for diagnosis of malaria has several limitations that necessitate field evaluation of alternative diagnostic methods especially in low income countries of sub-Saharan Africa where malaria is endemic. Methods The accuracy of axillary temperature, health centre (HC microscopy, expert microscopy and a HRP2-based rapid diagnostic test (Paracheck was compared in predicting malaria infection using polymerase chain reaction (PCR as the gold standard. Three hundred patients with a clinical suspicion of malaria based on fever and or history of fever from a low and high transmission setting in Uganda were consecutively enrolled and provided blood samples for all tests. Accuracy of each test was calculated overall with 95% confidence interval and then adjusted for age-groups and level of transmission intensity using a stratified analysis. The endpoints were: sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV. This study is registered with Clinicaltrials.gov, NCT00565071. Results Of the 300 patients, 88(29.3% had fever, 56(18.7% were positive by HC microscopy, 47(15.7% by expert microscopy, 110(36.7% by Paracheck and 89(29.7% by PCR. The overall sensitivity >90% was only shown by Paracheck 91.0% [95%CI: 83.1-96.0]. The sensitivity of expert microscopy was 46%, similar to HC microscopy. The superior sensitivity of Paracheck compared to microscopy was maintained when data was stratified for transmission intensity and age. The overall specificity rates were: Paracheck 86.3% [95%CI: 80.9-90.6], HC microscopy 93.4% [95%CI: 89.1-96.3] and expert microscopy 97.2% [95%CI: 93.9-98.9]. The NPV >90% was shown by Paracheck 95.8% [95%CI: 91.9-98.2]. The overall PPV was Conclusion The HRP2-based RDT has shown superior sensitivity compared to

  17. Comparing the ISO-recommended and the cumulative data-reduction algorithms in S-on-1 laser damage test by a reverse approach method

    Science.gov (United States)

    Zorila, Alexandru; Stratan, Aurel; Nemes, George

    2018-01-01

    We compare the ISO-recommended (the standard) data-reduction algorithm used to determine the surface laser-induced damage threshold of optical materials by the S-on-1 test with two newly suggested algorithms, both named "cumulative" algorithms/methods, a regular one and a limit-case one, intended to perform in some respects better than the standard one. To avoid additional errors due to real experiments, a simulated test is performed, named the reverse approach. This approach simulates the real damage experiments, by generating artificial test-data of damaged and non-damaged sites, based on an assumed, known damage threshold fluence of the target and on a given probability distribution function to induce the damage. In this work, a database of 12 sets of test-data containing both damaged and non-damaged sites was generated by using four different reverse techniques and by assuming three specific damage probability distribution functions. The same value for the threshold fluence was assumed, and a Gaussian fluence distribution on each irradiated site was considered, as usual for the S-on-1 test. Each of the test-data was independently processed by the standard and by the two cumulative data-reduction algorithms, the resulting fitted probability distributions were compared with the initially assumed probability distribution functions, and the quantities used to compare these algorithms were determined. These quantities characterize the accuracy and the precision in determining the damage threshold and the goodness of fit of the damage probability curves. The results indicate that the accuracy in determining the absolute damage threshold is best for the ISO-recommended method, the precision is best for the limit-case of the cumulative method, and the goodness of fit estimator (adjusted R-squared) is almost the same for all three algorithms.

  18. The local lymph node assay compared with the human maximization test as an indicator of allergic potency in humans using patch test clinic populations.

    Science.gov (United States)

    Zaghi, Danny; Maibach, Howard I

    2009-01-01

    The human maximization test (HMT) is a method to evaluate potency in humans, while the local lymph node assay (LLNA) is a test method that allows for the measuring of the allergic potency of a substance in a rodent. It has been proposed that an EC3 value (the value obtained by the LLNA test, ie, the concentration of an allergen leading to a 3-fold increase of baseline proliferation rate) would be a reliable indicator for a compound's allergic potency in humans. This paper compares the correlation between the EC3 value of a compound and its allergic occurrence in the general population with the correlation between the HMT of the compound and its allergic occurrence in the general population, to determine the relationship to potency. The correlation values when outliers were removed from the sample were -0.56 and -0.71 for LLNA and HMT, respectively, suggesting that there is a possible 20% error margin in LLNA's ability to predict potency. The data also suggest that other factors (such as exposure) could play up to a 30% role in the determination of allergic occurrence in the general population. The potency assays might be made more clinically relevant for predicting allergic frequencies by including a frequency factor and other factors in its dermatotoxicological interpretation.

  19. Vaginal Swab Test Compared With the Urethral Q-tip Test for Urethral Mobility Measurement: A Randomized Controlled Trial.

    Science.gov (United States)

    Meyer, Isuzu; Szychowski, Jeff M; Illston, Jana D; Parden, Alison M; Richter, Holly E

    2016-02-01

    To assess whether use of a vaginal cotton-tipped swab is equivalent to the standard Q-tip test regarding urethral mobility. Secondarily, to examine whether both tests agree in hypermobility diagnosis, discomfort level, and patients' preference. In this randomized crossover trial, women with stress urinary incontinence without prolapse beyond the hymen were randomized to undergo either a vaginal or urethral mobility test first followed by the alternate approach. The primary outcome was the difference in rotation angle, from resting to maximum strain, between tests. The equivalence margin was ±10°. The secondary outcome was agreement in hypermobility diagnosis using two definitions: 1) maximum straining angle of 30° or greater from the horizontal plane; and 2) rotation angle 30° or greater. Discomfort was assessed using a 0-10 visual analog scale. Using 90% power assuming a standard deviation of 20°, 36 and 139 patients were needed for 10° and 5° equivalence margins, respectively. From January 2014 to March 2015, 140 women were randomized. The mean difference between the two tests was 5.1° (95% confidence interval 3.2-6.9°), meeting the predefined equivalence criteria. In the hypermobility diagnosis, the urethral and vaginal tests had no disagreement using definition 1 (P=.23), whereas the two tests disagreed using definition 2 (P=.03). The urethral approach had a higher discomfort level (Pstandard Q-tip test in measuring urethral mobility with less discomfort and is preferred by patients.

  20. A comparative study of Widal test with blood culture in the diagnosis of typhoid fever in febrile patients.

    Science.gov (United States)

    Andualem, Gizachew; Abebe, Tamrat; Kebede, Nigatu; Gebre-Selassie, Solomon; Mihret, Adane; Alemayehu, Haile

    2014-09-17

    Typhoid fever is a major health problem in developing countries and its diagnosis on clinical ground is difficult. Diagnosis in developing countries including Ethiopia is mostly done by Widal test. However, the value of the test has been debated. Hence, evaluating the result of this test is necessary for correct interpretation of the result. The main aim of this study was to compare the result of Widal test and blood culture in the diagnosis of typhoid fever in febrile patients. Blood samples were collected from 270 febrile patients with symptoms clinically similar to typhoid fever and visiting St. Paul's General Specialized Hospitals from mid December 2010 to March 2011. Blood culture was used to isolate S.typhi and S.paratyphi. Slide agglutination test and tube agglutination tests were used for the determination of antibody titer. An antibody titer of ≥1:80 for anti TO and ≥1:160 for anti TH were taken as a cut of value to indicate recent infection of typhoid fever. One hundred and eighty six (68.9%) participants were females and eighty four (31.1%) were males. 7 (2.6%) cases of S. typhi and 4 (1.5%) cases of S. paratyphi were identified with the total prevalence of typhoid fever 4.1%. The total number of patients who have indicative of recent infection by either of O and H antigens Widal test is 88 (32.6%). The sensitivity, specificity, Positive predictive Value and Negative predictive Value of Widal test were 71.4%, 68.44%, 5.7% and 98.9% respectively. Widal test has a low sensitivity, specificity and PPV, but it has good NPV which indicates that negative Widal test result have a good indication for the absence of the disease.

  1. Cardiopulmonary Exercise Testing in Fontan Patients With and Without Isomerism (Heterotaxy) as Compared to Patients With Primary Ciliary Dyskinesia and Subjects With Structurally Normal Hearts

    DEFF Research Database (Denmark)

    Loomba, Rohit S; Danduran, Michael; Nielsen, Kim G

    2017-01-01

    with and without isomerism. We have now compared these finding with those from patients with primary ciliary dyskinesia, as many patients with isomerism have ciliary dyskinesia. We identified patients having the Fontan circulation with and without isomerism who had undergone cardiopulmonary exercise testing......, comparing the findings from healthy individuals undergoing exercise, and a comparable number of individuals with primary ciliary dyskinesia but no congenital heart disease. We were able to include a total of 68 patients in our study, with 17 in each of the four groups. Cardiopulmonary exercise testing...

  2. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  3. Test-retest reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression--a systematic review and meta-analysis.

    Science.gov (United States)

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2015-11-01

    Schizoaffective disorder is a frequent diagnosis, and its reliability is subject to ongoing discussion. We compared the diagnostic reliability of schizoaffective disorder with its main differential diagnoses. We systematically searched Medline, Embase, and PsycInfo for all studies on the test-retest reliability of the diagnosis of schizoaffective disorder as compared with schizophrenia, bipolar disorder, and unipolar depression. We used meta-analytic methods to describe and compare Cohen's kappa as well as positive and negative agreement. In addition, multiple pre-specified and post hoc subgroup and sensitivity analyses were carried out. Out of 4,415 studies screened, 49 studies were included. Test-retest reliability of schizoaffective disorder was consistently lower than that of schizophrenia (in 39 out of 42 studies), bipolar disorder (27/33), and unipolar depression (29/35). The mean difference in kappa between schizoaffective disorder and the other diagnoses was approximately 0.2, and mean Cohen's kappa for schizoaffective disorder was 0.50 (95% confidence interval: 0.40-0.59). While findings were unequivocal and homogeneous for schizoaffective disorder's diagnostic reliability relative to its three main differential diagnoses (dichotomous: smaller versus larger), heterogeneity was substantial for continuous measures, even after subgroup and sensitivity analyses. In clinical practice and research, schizoaffective disorder's comparatively low diagnostic reliability should lead to increased efforts to correctly diagnose the disorder. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Comparative assessment of seller's staining test (SST) and direct ...

    African Journals Online (AJOL)

    the only standard method. Objective: This study was designed to assess the sensitivity and specificity of the SST in relation to the 'gold standard' dFAT in diagnosis of rabies in Nigeria. Methods: A total of 88 animal specimens submitted to the Rabies National Reference Laboratory, Nigeria were routinely tested for rabies by ...

  5. Cantilever beam test in Zr-2.5%Nb: Comparative study between pipe material obtained by laminating and wire drawing

    International Nuclear Information System (INIS)

    Gomez, A G; Szieber, W C; Vizcaino, P; Loureiro, N; Bianchi, D R; Banchik, A D

    2012-01-01

    The Zr-2.5Nb alloy is used in the manufacture of pressure tubes for the CANDU nuclear power reactors. These tubes are subjected to severe service conditions: one o f them, the heavy water corrosion due to the coolant generates release of hydrogen, part of which ingress in the material raising its initial concentration and exposing them to a phenomena referred as delay hydrogen cracking. The results presented in this paper show the performance of a pressure tube of domestic manufacture under conditions of tension and hydrogen content in order to be compared with the behavior of a standard pressure tube in operation in the nuclear power plant. To do this is, cantilever notched and pre cracked samples were hydrided from both kinds of tubes. Each one of these samples was subjected to the cantilever beam test, which consists in a bending test performed in a furnace at 250 o C. Starting from a stress intensity factor Ki which determines the propagation start of the crack, the growth is followed by the acoustic emission technique up to the arrest of the crack by controlling the bending load. This work presents the comparative data such as critical voltages, behavior of hydrides, and DHC parameters from both trials. Although the number of tests is reduced; results show a good performance of the tubes of domestic manufacture (author)

  6. Test-retest repeatability of child's respiratory symptoms and perceived indoor air quality - comparing self- and parent-administered questionnaires.

    Science.gov (United States)

    Lampi, Jussi; Ung-Lanki, Sari; Santalahti, Päivi; Pekkanen, Juha

    2018-02-09

    Questionnaires can be used to assess perceived indoor air quality and symptoms in schools. Questionnaires for primary school aged children have traditionally been parent-administered, but self-administered questionnaires would be easier to administer and may yield as good, if not better, information. Our aim was to compare the repeatability of self- and parent-administered indoor air questionnaires designed for primary school aged pupils. Indoor air questionnaire with questions on child's symptoms and perceived indoor air quality in schools was sent to parents of pupils aged 7-12 years in two schools and again after two weeks. Slightly modified version of the questionnaire was administered to pupils aged 9-12 years in another two schools and repeated after a week. 351 (52%) parents and 319 pupils (86%) answered both the first and the second questionnaire. Test-retest repeatability was assessed with intra-class correlation (ICC) and Cohen's kappa coefficients (k). Test-retest repeatability was generally between 0.4-0.7 (ICC; k) in both self- and parent-administered questionnaire. In majority of the questions on symptoms and perceived indoor air quality test-retest repeatability was at the same level or slightly better in self-administered compared to parent-administered questionnaire. Agreement of self- and parent administered questionnaires was generally indoor air quality. Children aged 9-12 years can give as, or even more, repeatable information about their respiratory symptoms and perceived indoor air quality than their parents. Therefore, it may be possible to use self-administered questionnaires in future studies also with children.

  7. Comparing three novel endpoints for developmental osteotoxicity in the embryonic stem cell test

    International Nuclear Information System (INIS)

    Nieden, Nicole I. zur; Davis, Lesley A.; Rancourt, Derrick E.

    2010-01-01

    Birth defects belong to the most serious side effects of pharmaceutical compounds or environmental chemicals. In vivo, teratogens most often affect the normal development of bones, causing growth retardation, limb defects or craniofacial malformations. The embryonic stem cell test (EST) is one of the most promising models that allow the in vitro prediction of embryotoxicity, with one of its endpoints being bone tissue development. The present study was designed to describe three novel inexpensive endpoints to assess developmental osteotoxicity using the model compounds penicillin G (non-teratogenic), 5-fluorouracil (strong teratogen) and all-trans retinoic acid (bone teratogen). These three endpoints were: quantification of matrix incorporated calcium by (1) morphometric analysis and (2) measurement of calcium levels as well as (3) activity of alkaline phosphatase, an enzyme involved in matrix calcification. To evaluate our data, we have compared the concentration curves and resulting ID 50 s of the new endpoints with mRNA expression for osteocalcin. Osteocalcin is an exclusive marker found only in mineralized tissues, is regulated upon compound treatment and reliably predicts the potential of a chemical entity acting as a bone teratogen. By comparing the new endpoints to quantitative expression of osteocalcin, which we previously identified as suitable to detect developmental osteotoxicity, we were ultimately able to illustrate IMAGE analysis and Ca 2+ deposition assays as two reliable novel endpoints for the EST. This is of particular importance for routine industrial assessment of novel compounds as these two new endpoints may substitute previously used molecular read-out methods, which are often costly and time-consuming.

  8. Orthodontic brackets removal under shear and tensile bond strength resistance tests - a comparative test between light sources

    Science.gov (United States)

    Silva, P. C. G.; Porto-Neto, S. T.; Lizarelli, R. F. Z.; Bagnato, V. S.

    2008-03-01

    We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 ± 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

  9. Soil solution extraction techniques for microbial ecotoxicity testing: a comparative evaluation.

    Science.gov (United States)

    Tiensing, T; Preston, S; Strachan, N; Paton, G I

    2001-02-01

    The suitability of two different techniques (centrifugation and Rhizon sampler) for obtaining the interstitial pore water of soil (soil solution), integral to the ecotoxicity assessment of metal contaminated soil, were investigated by combining chemical analyses and a luminescence-based microbial biosensor. Two different techniques, centrifugation and Rhizon sampler, were used to extract the soil solution from Insch (a loamy sand) and Boyndie (a sandy loam) soils, which had been amended with different concentrations of Zn and Cd. The concentrations of dissolved organic carbon (DOC), major anions (F- , CI-, NO3, SO4(2-)) and major cations (K+, Mg2+, Ca2+) in the soil solutions varied depending on the extraction technique used. Overall, the concentrations of Zn and Cd were significantly higher in the soil solution extracted using the centrifugation technique compared with that extracted using the Rhizon sampler technique. Furthermore, the differences observed between the two extraction techniques depended on the type of soil from which the solution was being extracted. The luminescence-based biosensor Escherichia coli HB101 pUCD607 was shown to respond to the free metal concentrations in the soil solutions and showed that different toxicities were associated with each soil, depending on the technique used to extract the soil solution. This study highlights the need to characterise the type of extraction technique used to obtain the soil solution for ecotoxicity testing in order that a representative ecotoxicity assessment can be carried out.

  10. To What Extent is Drinking Water Tested in Sub-Saharan Africa? A Comparative Analysis of Regulated Water Quality Monitoring.

    Science.gov (United States)

    Peletz, Rachel; Kumpel, Emily; Bonham, Mateyo; Rahman, Zarah; Khush, Ranjiv

    2016-03-02

    Water quality information is important for guiding water safety management and preventing water-related diseases. To assess the current status of regulated water quality monitoring in sub-Saharan Africa, we evaluated testing programs for fecal contamination in 72 institutions (water suppliers and public health agencies) across 10 countries. Data were collected through written surveys, in-person interviews, and analysis of microbial water quality testing levels. Though most institutions did not achieve the testing levels specified by applicable standards or World Health Organization (WHO) Guidelines, 85% of institutions had conducted some microbial water testing in the previous year. Institutions were more likely to meet testing targets if they were suppliers (as compared to surveillance agencies), served larger populations, operated in urban settings, and had higher water quality budgets (all p water providers and rural public health offices will require greater attention and additional resources to achieve regulatory compliance for water quality monitoring in sub-Saharan Africa. The cost-effectiveness of water quality monitoring should be improved by the application of risk-based water management approaches. Efforts to strengthen monitoring capacity should pay greater attention to program sustainability and institutional commitment to water safety.

  11. A comparative clinical study of efficacy of microimmuno assay with WIDAL-test in enteric fever in children

    Directory of Open Access Journals (Sweden)

    Gandarajapura Nagaraj Madhu

    2014-01-01

    Full Text Available The diagnosis of typhoid fever in young children is also a dilemma because of its manifestations and typical presentation may not be seen in all cases. Antibodies to Salmonella typhi antigen are developed in the human body, which can be detected as a diagnostic test for the enteric fever. Objective: This study was undertaken to compare the efficacy of WIDAL-test with micro-immunoassay (dot enzyme immunosorbent assay. Method: 40 cases of clinically suspected enteric fever cases were included in this study. Result: In the present study, nearly 92% were positive for micro immunoassay (dot-enzyme immunosorbent assay by Enterocheck-WB kit, 80% were positive for WIDAL and only 15% were culture positive. Immunoassay positive, but WIDAL negative cases were 20%, whereas WIDAL positive and immunoassay negative cases were only 7.5%. The positive predictivity of micro-immunoassay in diagnosing enteric fever is better than WIDAL both in 1st and 2nd week of illness. Micro-immunoassay done in the study was rapid in diagnosing the case. Conclusion: It is concluded from the present study that the micro-immunoassay (Enterocheck-WB is better than WIDAL-test in the diagnosis of enteric fever in children.

  12. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  13. Cross-cultural perspectives on decision making regarding noninvasive prenatal testing: A comparative study of Lebanon and Quebec.

    Science.gov (United States)

    Haidar, Hazar; Vanstone, Meredith; Laberge, Anne-Marie; Bibeau, Gilles; Ghulmiyyah, Labib; Ravitsky, Vardit

    2018-01-01

    Noninvasive prenatal testing (NIPT), based on the detection of cell-free fetal DNA in maternal blood, has transformed the landscape of prenatal care by offering clinical benefits (noninvasive, high specificity and sensitivity, early detection of abnormalities) compared to existing prenatal screening tests. NIPT has expanded rapidly and is currently commercially available in most of the world. As NIPT spreads globally, culturally sensitive and ethically sound implementation will require policies that take into consideration the social and cultural context of prenatal testing decisions. In a Western context, the main ethical argument for providing access and public funding of prenatal tests is the promotion of reproductive autonomy (also referred to as "procreative liberty" and "reproductive freedom"), by enabling pregnant women and couples to access information about the fetus in order to choose a certain course of action for pregnancy management (continuation of pregnancy and preparation for birth or termination). So how is the framework of reproductive autonomy operationalized in non-Western cultural contexts? We used Quebec, Canada, and Beirut, Lebanon, for case studies to explore what ethical considerations related to reproductive autonomy should guide the implementation of the test in various cultural contexts. To answer this question, we conducted a qualitative study to (1) explore the perceptions, values, and preferences of pregnant women and their partners about NIPT and (2) examine how these values and perceptions influence reproductive autonomy and decision making in relation to NIPT in these two different cultural settings, Lebanon and Quebec. Our findings may guide health care professionals in providing counseling and in helping women and their partners make better informed prenatal testing decisions. Further, at a policy level, such understanding might inform the development of local guidelines and policies that are appropriate to each context.

  14. The Osteoporosis Self-Assessment Tool versus alternative tests for selecting postmenopausal women for bone mineral density assessment: a comparative systematic review of accuracy

    DEFF Research Database (Denmark)

    Rud, B; Hilden, J; Hyldstrup, L

    2008-01-01

    for Stiffness Index assessed by calcaneal quantitative ultrasonography than for OST (relative sDOR: 1.9, p = 0.005). Studies were few in Asian and black women. Methodological quality, assessed with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist, was generally low. CONCLUSIONS: In white......We performed a systematic review of studies comparing the Osteoporosis Self-Assessment Tool (OST) and other tests used to select women for bone mineral density (BMD) assessment. In comparative meta-analyses, we found that the accuracy of OST was similar to other tests that are based on information...... from the medical history. By contrast, assessment by quantitative ultrasonography at the heel was more accurate than OST in discriminating between women with high and low BMD. The methodological quality of the included studies was generally low. INTRODUCTION: Numerous tests are suggested for triaging...

  15. Evaluating statistical tests on OLAP cubes to compare degree of disease.

    Science.gov (United States)

    Ordonez, Carlos; Chen, Zhibo

    2009-09-01

    Statistical tests represent an important technique used to formulate and validate hypotheses on a dataset. They are particularly useful in the medical domain, where hypotheses link disease with medical measurements, risk factors, and treatment. In this paper, we propose to compute parametric statistical tests treating patient records as elements in a multidimensional cube. We introduce a technique that combines dimension lattice traversal and statistical tests to discover significant differences in the degree of disease within pairs of patient groups. In order to understand a cause-effect relationship, we focus on patient group pairs differing in one dimension. We introduce several optimizations to prune the search space, to discover significant group pairs, and to summarize results. We present experiments showing important medical findings and evaluating scalability with medical datasets.

  16. Comparative analysis of quality control tests on computed tomography in accordance with national and international laws; Analise comparativa dos testes de controle de qualidade em tomografia computadorizada de acordo com as legislacoes nacional e internacional

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Fernando S.; Vasconcelos, Rebeca S.; Goncalves, Marcel S.; Oliveira, Marcus V.L. de, E-mail: fernando_siramos@hotmail.com, E-mail: marcusradiology@gmail.com [Instituto Federal da Bahia (IFBA), Salvador, BA (Brazil)

    2014-07-01

    The objective of this study is to perform a comparative analysis between the Brazilian legislation and internationals protocols, with respect to the quality control tests for computerized tomography. We used 07 references, published from 1998-2012: the Protocolo Brasileiro - Portaria 453/98 SVS/MS and the Guia de Radiodiagnostico Medico da ANVISA; Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications of the IAEA; European Protocol - European Guidelines on Quality Criteria for Computed Tomography of the EUR No. 16262 EN; Radiation Protection No. 162 - Criteria for Acceptability of Medical Radiology, Nuclear Medicine and Radiotherapy of the European Commission; the Protocols of Control de Calidad en Radiodiagnostico IAEA / ARCAL XLIX; and the Protocolo Espanol de Control de Calidad en Radiodignostico. The comparative analysis of these legislations was based on aspects of tolerance / limit, frequency and objectives of the recommended tests. Were found 18 tests in the Brazilian legislation. The tests were grouped according to their nature (dosimetric tests / exposure and geometric tests and image quality tests). Among the evaluated protocols was identified divergence between tests contained in the documents and the criteria of assessment set out in this work. It is clear, moreover, that for certain documents are not observed tolerances, well-defined methodologies and even frequency of testing. We conclude that the current legislation in Brazil differs in certain respects from international protocols analyzed, although this has a great numbers of quality control tests. However, it is necessary that the Brazilian legislation takes into account technological advances presented to time.

  17. The Hug-up Test: A New, Sensitive Diagnostic Test for Supraspinatus Tears

    Directory of Open Access Journals (Sweden)

    Yu-Lei Liu

    2016-01-01

    Full Text Available Background: The supraspinatus tendon is the most commonly affected tendon in rotator cuff tears. Early detection of a supraspinatus tear using an accurate physical examination is, therefore, important. However, the currently used physical tests for detecting supraspinatus tears are poor diagnostic indicators and involve a wide range of sensitivity and specificity values. Therefore, the aim of this study was to establish a new physical test for the diagnosis of supraspinatus tears and evaluate its accuracy in comparison with conventional tests. Methods: Between November 2012 and January 2014, 200 consecutive patients undergoing shoulder arthroscopy were prospectively evaluated preoperatively. The hug-up test, empty can (EC test, full can (FC test, Neer impingement sign, and Hawkins-Kennedy impingement sign were used and compared statistically for their accuracy in terms of supraspinatus tears, with arthroscopic findings as the gold standard. Muscle strength was precisely quantified using an electronic digital tensiometer. Results: The prevalence of supraspinatus tears was 76.5%. The hug-up test demonstrated the highest sensitivity (94.1%, with a low negative likelihood ratio (NLR, 0.08 and comparable specificity (76.6% compared with the other four tests. The area under the receiver operating characteristic curve for the hug-up test was 0.854, with no statistical difference compared with the EC test (z = 1.438, P = 0.075 or the FC test (z = 1.498, P = 0.067. The hug-up test showed no statistical difference in terms of detecting different tear patterns according to the position (χ2 = 0.578, P = 0.898 and size (Fisher′s exact test, P > 0.999 compared with the arthroscopic examination. The interobserver reproducibility of the hug-up test was high, with a kappa coefficient of 0.823. Conclusions: The hug-up test can accurately detect supraspinatus tears with a high sensitivity, comparable specificity, and low NLR compared with the conventional

  18. Comparative Performance of Four Single Extreme Outlier Discordancy Tests from Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Surendra P. Verma

    2014-01-01

    Full Text Available Using highly precise and accurate Monte Carlo simulations of 20,000,000 replications and 102 independent simulation experiments with extremely low simulation errors and total uncertainties, we evaluated the performance of four single outlier discordancy tests (Grubbs test N2, Dixon test N8, skewness test N14, and kurtosis test N15 for normal samples of sizes 5 to 20. Statistical contaminations of a single observation resulting from parameters called δ from ±0.1 up to ±20 for modeling the slippage of central tendency or ε from ±1.1 up to ±200 for slippage of dispersion, as well as no contamination (δ=0 and ε=±1, were simulated. Because of the use of precise and accurate random and normally distributed simulated data, very large replications, and a large number of independent experiments, this paper presents a novel approach for precise and accurate estimations of power functions of four popular discordancy tests and, therefore, should not be considered as a simple simulation exercise unrelated to probability and statistics. From both criteria of the Power of Test proposed by Hayes and Kinsella and the Test Performance Criterion of Barnett and Lewis, Dixon test N8 performs less well than the other three tests. The overall performance of these four tests could be summarized as N2≅N15>N14>N8.

  19. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    Science.gov (United States)

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (pgrupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (pgrupos. O uso de embalagens estéreis (sterile pack) diminui a carga microbiana dos frascos de envasamentos, o que diminuiria a chance de exposição a uma potencial contaminação da solução anestésica.

  20. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia.

    Science.gov (United States)

    Gaitán-Duarte, Hernando Guillermo; Newman, Lori; Laverty, Maura; Habib, Ndema Abu; González-Gordon, Lina María; Ángel-Müller, Edith; Abella, Catleya; Barros, Esther Cristina; Rincón, Carlos; Caicedo, Sidia; Gómez, Bertha; Pérez, Freddy

    2016-12-01

    To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC) centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A) or to dual HIV and syphilis rapid diagnostic tests (Arm B). The four main outcomes measured were: (1) acceptability of the test, (2) uptake in testing, (3) treatment on the same day (that is, timely treatment), and (4) treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69%) in Arm A and 16 of 20 patients (80%) in Arm B (relative risk (RR), 1.10; 95% confidence interval (CI): (1.00 -1.20). Treatment at any time was given to 24 of 29 patients (83%) in Arm A and to 20 of 20 (100%) in Arm B (RR, 1.11; 95% CI: 1.01-1.22). There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  1. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia

    Directory of Open Access Journals (Sweden)

    Hernando Guillermo Gaitán-Duarte

    Full Text Available ABSTRACT Objective To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. Methods A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A or to dual HIV and syphilis rapid diagnostic tests (Arm B. The four main outcomes measured were: (1 acceptability of the test, (2 uptake in testing, (3 treatment on the same day (that is, timely treatment, and (4 treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. Results A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69% in Arm A and 16 of 20 patients (80% in Arm B (relative risk (RR, 1.10; 95% confidence interval (CI: (1.00 −1.20. Treatment at any time was given to 24 of 29 patients (83% in Arm A and to 20 of 20 (100% in Arm B (RR, 1.11; 95% CI: 1.01−1.22. Conclusions There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  2. The Method of Adaptive Comparative Judgement

    Science.gov (United States)

    Pollitt, Alastair

    2012-01-01

    Adaptive Comparative Judgement (ACJ) is a modification of Thurstone's method of comparative judgement that exploits the power of adaptivity, but in scoring rather than testing. Professional judgement by teachers replaces the marking of tests; a judge is asked to compare the work of two students and simply to decide which of them is the better.…

  3. Social Connectedness and Life Satisfaction: Comparing Mean Levels for 2 Undergraduate Samples and Testing for Improvement Based on Brief Counseling

    Science.gov (United States)

    Blau, Gary; DiMino, John; DeMaria, Peter A.; Beverly, Clyde; Chessler, Marcy; Drennan, Rob

    2016-01-01

    Objectives: Comparing the mean levels of social connectedness and life satisfaction, and analyzing their relationship for 2 undergraduate samples, and testing for an increase in their means for a brief counseling sample. Participants: Between October 2013 and May 2015, 3 samples were collected: not-in-counseling (NIC; n = 941), initial counseling…

  4. Proficiency Testing in Nondestructive Testing (NDT)

    International Nuclear Information System (INIS)

    Amry Amin Abbas; Suhairy Sani; Mohamad Pauzi Ismail; Abd Nassir Ibrahim

    2014-01-01

    Department of Standard Malaysia (DSM) launched myPTP programme on 31 December 2013 in accordance to ISO/IC 17043. The standard states the requirements for Proficiency Testing. The provider of these services is called Proficiency Testing Provider (PTP). The role of PTP is to compare the proficiency level between inspection bodies or laboratories. With the assistance of expert panel, the PTP will determine the assigned value as reference to be compared to the values obtained from the inspection bodies or laboratories. Quality wise, this services is important as participation will improve wuality of the inspection quality continuously and increase confidence level of client and improve safety level. Requirement of PT in NDT is mentioned in SC1.5- Specific Criteria for Accreditation of Mechanical Testing and Non-Destructive Testing (NDT) for MS ISO/IEC17025 and MTR2- MIBAS Technical Requirements for Accreditation of NDT. This paper explains and discusses the result of this proficiency test done on a number of NDT companies that participated. (author)

  5. To What Extent is Drinking Water Tested in Sub-Saharan Africa? A Comparative Analysis of Regulated Water Quality Monitoring

    Directory of Open Access Journals (Sweden)

    Rachel Peletz

    2016-03-01

    Full Text Available Water quality information is important for guiding water safety management and preventing water-related diseases. To assess the current status of regulated water quality monitoring in sub-Saharan Africa, we evaluated testing programs for fecal contamination in 72 institutions (water suppliers and public health agencies across 10 countries. Data were collected through written surveys, in-person interviews, and analysis of microbial water quality testing levels. Though most institutions did not achieve the testing levels specified by applicable standards or World Health Organization (WHO Guidelines, 85% of institutions had conducted some microbial water testing in the previous year. Institutions were more likely to meet testing targets if they were suppliers (as compared to surveillance agencies, served larger populations, operated in urban settings, and had higher water quality budgets (all p < 0.05. Our results indicate that smaller water providers and rural public health offices will require greater attention and additional resources to achieve regulatory compliance for water quality monitoring in sub-Saharan Africa. The cost-effectiveness of water quality monitoring should be improved by the application of risk-based water management approaches. Efforts to strengthen monitoring capacity should pay greater attention to program sustainability and institutional commitment to water safety.

  6. Usefulness of the UBCTM (urinary bladder cancer) test compared to urinary cytology for transitional cell carcinoma of the bladder in patients with hematuria

    International Nuclear Information System (INIS)

    Gil, Myung Cheol; Kang, Do Young; Seong, Youl Koon

    2001-01-01

    Urinary cytology and cystoscopic exam are effective methods for diagnosis of transitional cell carcinoma (TCC). But the former shows drawbacks such as the need for a well-trained examiner, and wide imprecision related to the variability of microscopic exam; the latter is a invasive method. UBC TM test detects the epitope on specific cytokeratin fragments released from epithelium of bladder cancer by immunoradiometric assay. We compared UBC TM test with urinary cytology for diagnosis of TCC to evaluate the utility of UBC TM test. Eighty-four patients with hematuria were included in our study, UBC TM tests (IDL Biotech, Sweden) were assayed in mid-stream urine according to the ordinary assay protocol. Nineteen patients were confirmed as TCC by cystoscopic examination and underwent transurethral resection (Group A). Other patients had various benign urinary tract conditions (Group B). Samples were considered positive as the UBC TM concentration was greater than 12 μg/L. UBC TM levels were significantly different between group A (95.9 ±166.4 μg/L) and group B (19.2 ± 85.6 μg/L)(p TM test and 100% (65/65) in cytology. UBC TM test was significantly more sensitive in stage Ta, T 1 tumors (84.6 vs 38.5%, p TM test showed a tendency to be more sensitive as the grade was higher (83.3% in Grade 1, 90% in Grade II and 100% in Grade III). UBC TM test could be a useful method in distinguishing TCC from other benign genitourinary diseases. Moreover, UBC TM test could be an especially valuable marker for diagnosis of TCC in patients with early TCC of low grade TCC compared to urinary cytology. Therefore, mbined use of UBC TM test in association with cytology is helpful to overcome the limited sensitivity of cytology

  7. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  8. Comparative Model Tests of SDP and CFA Pile Groups in Non-Cohesive Soil

    Science.gov (United States)

    Krasiński, Adam; Kusio, Tomasz

    2015-02-01

    The research topic relates to the subject of deep foundations supported on continuous flight auger (CFA) piles and screw displacement piles (SDP). The authors have decided to conduct model tests of foundations supported on the group of piles mentioned above and also the tests of the same piles working as a single. The tests are ongoing in Geotechnical Laboratory of Gdaňsk University of Technology. The description of test procedure, interpretation and analysis of the preliminary testing series results are presented in the paper.

  9. Comparative Assessment of the Heart's Functioning by Using the Akabane Test and Classical Methods of Instrumental Examination

    Directory of Open Access Journals (Sweden)

    Valery Muzhikov

    2017-06-01

    Full Text Available Acupuncture physicians have studied the application of reflexotherapy to cardiology. However, no one has investigated the connection of ancient Chinese diagnostic methods with modern tools. A total of 102 patients (54 men and 48 women with heart pathology, namely, sick-sinus syndrome, Wolff–Parkinson–White syndrome, and atrioventricular blockade, were studied using the usual instrumental methods (transesophageal electrophysiological study of the heart, echocardiography, after which they underwent Akabane thermopuncture testing as in traditional Chinese medicine. The results of cardio examination from one side of the Akabane test with that from the other side were compared by means of a multiple stepwise regression analysis. We revealed the effects on the characteristic pattern of acupuncture channel lesions inherent in a definite heart pathology, i.e., the most vulnerable acupuncture channel (AC, of such factors as disturbances of the contractile, conductive, or automatic heart functions, and changes in the chambers' size or circulation volume. Сhanges in the indices of the left and the right branches of these channels usually reflect the opposing natures of the changes in these indicators, which should be considered in reflexotherapy. The main value of the Akabane test along with the use of mathematical analysis lies in early, quick, and inexpensive detection of the above-mentioned heart disturbances.

  10. Underwater floating robot-fish: a comparative analysis of the results of mathematical modelling and full-scale tests of the prototype

    Directory of Open Access Journals (Sweden)

    Jatsun Sergey

    2017-01-01

    Full Text Available The article presents a comparative analysis of the results of computer mathematical modelling of the motion of the underwater robot-fish implemented by using the MATLAB / Simulink package and fullscale tests of an experimental model developed in the laboratory of mechatronics and robotics of the SouthWest State University.

  11. Comparative Model Tests of SDP and CFA Pile Groups in Non-Cohesive Soil

    Directory of Open Access Journals (Sweden)

    Krasiński Adam

    2015-02-01

    Full Text Available The research topic relates to the subject of deep foundations supported on continuous flight auger (CFA piles and screw displacement piles (SDP. The authors have decided to conduct model tests of foundations supported on the group of piles mentioned above and also the tests of the same piles working as a single. The tests are ongoing in Geotechnical Laboratory of Gdaňsk University of Technology. The description of test procedure, interpretation and analysis of the preliminary testing series results are presented in the paper.

  12. Using Relative Statistics and Approximate Disease Prevalence to Compare Screening Tests.

    Science.gov (United States)

    Samuelson, Frank; Abbey, Craig

    2016-11-01

    Schatzkin et al. and other authors demonstrated that the ratios of some conditional statistics such as the true positive fraction are equal to the ratios of unconditional statistics, such as disease detection rates, and therefore we can calculate these ratios between two screening tests on the same population even if negative test patients are not followed with a reference procedure and the true and false negative rates are unknown. We demonstrate that this same property applies to an expected utility metric. We also demonstrate that while simple estimates of relative specificities and relative areas under ROC curves (AUC) do depend on the unknown negative rates, we can write these ratios in terms of disease prevalence, and the dependence of these ratios on a posited prevalence is often weak particularly if that prevalence is small or the performance of the two screening tests is similar. Therefore we can estimate relative specificity or AUC with little loss of accuracy, if we use an approximate value of disease prevalence.

  13. Eliciting preferences for priority setting in genetic testing: a pilot study comparing best-worst scaling and discrete-choice experiments.

    Science.gov (United States)

    Severin, Franziska; Schmidtke, Jörg; Mühlbacher, Axel; Rogowski, Wolf H

    2013-11-01

    Given the increasing number of genetic tests available, decisions have to be made on how to allocate limited health-care resources to them. Different criteria have been proposed to guide priority setting. However, their relative importance is unclear. Discrete-choice experiments (DCEs) and best-worst scaling experiments (BWSs) are methods used to identify and weight various criteria that influence orders of priority. This study tests whether these preference eliciting techniques can be used for prioritising genetic tests and compares the empirical findings resulting from these two approaches. Pilot DCE and BWS questionnaires were developed for the same criteria: prevalence, severity, clinical utility, alternatives to genetic testing available, infrastructure for testing and care established, and urgency of care. Interview-style experiments were carried out among different genetics professionals (mainly clinical geneticists, researchers and biologists). A total of 31 respondents completed the DCE and 26 completed the BWS experiment. Weights for the levels of the six attributes were estimated by conditional logit models. Although the results derived from the DCE and BWS experiments differed in detail, we found similar valuation patterns in the DCE and BWS experiments. The respondents attached greatest value to tests with high clinical utility (defined by the availability of treatments that reduce mortality and morbidity) and to testing for highly prevalent conditions. The findings from this study exemplify how decision makers can use quantitative preference eliciting methods to measure aggregated preferences in order to prioritise alternative clinical interventions. Further research is necessary to confirm the survey results.

  14. Face masks in radiotherapy of head and neck cancers: Comparative test of different materials

    International Nuclear Information System (INIS)

    Niewald, M.; Lehmann, W.; Scharding, B.; Berberich, W.; Schnabel, K.; Leetz, H.K.; Universitaet des Saarlandes, Homburg/Saar

    1986-01-01

    A most precise immobilisation of the patient's head is indispensabel in order to reach a high degree of exactness and reproducibility in radiotherapy of malignant head and neck tumors. Face masks made of different synthetic materials have proved to be a simple and economical solution for this problem. Based on our own experiences with ''Baycast Longuettes'' (manufacturing firm: Johnson and Johnson, Duesseldorf), eleven substances have been tested in the phantom (compound of plaster and synthetic resin, thermoplast, polyurethane foam, compounds of cotton and synthetic resin and fibre glass compounds). An appropriate material was ''Hexcelite'' (manufacturing firm: Medimex, Hamburg), a reticulated thermoplast which after warming up can be easily adapted to the patient's face and which guarantees a very good fixation of the head. As compared to solid masks, there is only a slight superposition of the depth dose of Co-60 gamma radiation by secondary electrons from the mask material. So that an increased rate of radiogenic dermatitides is not to be expected. (orig.) [de

  15. A Quick Test of Cognitive Speed for Comparing Processing Speed to Differentiate Adult Psychiatric Referrals With and Without Attention-Deficit/Hyperactivity Disorders

    OpenAIRE

    Wiig, Elisabeth Hemmersam; Nielsen, Niels Peter

    2012-01-01

    Objective: This retrospective study used A Quick Test of Cognitive Speed (AQT) to compare processing speed and efficiency measures by adults with attention-deficit/hyperactivity disorder (ADHD) or non-ADHD psychiatric disorders and healthy controls.

  16. Metabolic and clinical comparative analysis of treadmill six-minute walking test and cardiopulmonary exercise testing in obese and eutrophic women Análise clínica e metabólica comparativa entre o teste de caminhada de seis minutos e o teste de exercício cardiopulmonar em mulheres obesas e eutróficas

    Directory of Open Access Journals (Sweden)

    Luciana Di Thommazo-Luporini

    2012-12-01

    Full Text Available BACKGROUND: Impaired exercise tolerance is directly linked to decreased functional capacity as a consequence of obesity. OBJECTIVES: To analyze and compare the cardiopulmonary, metabolic, and perceptual responses during a cardiopulmonary exercise test (CPX and a treadmill six-minute walking test (tread6MWT in obese and eutrophic women. METHOD: Twenty-nine female participants, aged 20-45 years were included. Fourteen were allocated to the obese group and 15 to the eutrophic group. Anthropometric measurements and body composition assessment were performed. RESULTS: In both tests, obese women presented with significantly higher absolute oxygen uptake, minute ventilation, and systolic and diastolic blood pressure; they also presented with lower speed, distance walked, and oxygen uptake corrected by the weight compared to eutrophics. During the maximal exercise test, perceived dyspnea was greater and the respiratory exchange ratio was lower in obese subjects compared to eutrophics. During the submaximal test, carbon dioxide production, tidal volume, and heart rate were higher in obese subjects compared to eutrophic women. When analyzing possible correlations between the CPX and the tread6MWT at peak, there was a strong correlation for the variable heart rate and a moderate correlation for the variable oxygen uptake. The heart rate obtained in the submaximal test was able to predict the one obtained in the maximal test. Bland-Altman plots demonstrated the agreement between both tests to identify metabolic and physiological parameters at peak exercise. CONCLUSIONS: The six-minute walking test induced ventilatory, metabolic, and cardiovascular responses in agreement with the maximal testing. Thus, the six-minute walking test proves to be important for functional evaluation in the physical therapy routine.CONTEXTUALIZAÇÃO: A reduzida tolerância ao exercício está relacionada à diminuída capacidade funcional consequente da obesidade. Objetivos

  17. Metabolic and clinical comparative analysis of treadmill six-minute walking test and cardiopulmonary exercise testing in obese and eutrophic women Análise clínica e metabólica comparativa entre o teste de caminhada de seis minutos e o teste de exercício cardiopulmonar em mulheres obesas e eutróficas

    Directory of Open Access Journals (Sweden)

    Luciana Di Thommazo-Luporini

    2012-01-01

    Full Text Available BACKGROUND: Impaired exercise tolerance is directly linked to decreased functional capacity as a consequence of obesity. OBJECTIVES: To analyze and compare the cardiopulmonary, metabolic, and perceptual responses during a cardiopulmonary exercise test (CPX and a treadmill six-minute walking test (tread6MWT in obese and eutrophic women. METHOD: Twenty-nine female participants, aged 20-45 years were included. Fourteen were allocated to the obese group and 15 to the eutrophic group. Anthropometric measurements and body composition assessment were performed. RESULTS: In both tests, obese women presented with significantly higher absolute oxygen uptake, minute ventilation, and systolic and diastolic blood pressure; they also presented with lower speed, distance walked, and oxygen uptake corrected by the weight compared to eutrophics. During the maximal exercise test, perceived dyspnea was greater and the respiratory exchange ratio was lower in obese subjects compared to eutrophics. During the submaximal test, carbon dioxide production, tidal volume, and heart rate were higher in obese subjects compared to eutrophic women. When analyzing possible correlations between the CPX and the tread6MWT at peak, there was a strong correlation for the variable heart rate and a moderate correlation for the variable oxygen uptake. The heart rate obtained in the submaximal test was able to predict the one obtained in the maximal test. Bland-Altman plots demonstrated the agreement between both tests to identify metabolic and physiological parameters at peak exercise. CONCLUSIONS: The six-minute walking test induced ventilatory, metabolic, and cardiovascular responses in agreement with the maximal testing. Thus, the six-minute walking test proves to be important for functional evaluation in the physical therapy routine.CONTEXTUALIZAÇÃO: A reduzida tolerância ao exercício está relacionada à diminuída capacidade funcional consequente da obesidade. Objetivos

  18. Orthodontic brackets removal under shear and tensile bond strength resistance tests – a comparative test between light sources

    International Nuclear Information System (INIS)

    Silva, P C G; Porto-Neto, S T; Lizarelli, R F Z; Bagnato, V S

    2008-01-01

    We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 ± 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased

  19. Alternative Bio-Derived JP-8 Class Fuel and JP-8 Fuel: Flame Tube Combustor Test Results Compared using a GE TAPS Injector Configuration

    Science.gov (United States)

    Hicks, Yolanda R.; Anderson, Robert; Tedder, Sarah

    2016-01-01

    This paper presents results from tests in a NASA Glenn Research Center (GRC) flame tube facility, where a bio-derived alternate fuel was compared with JP-8 for emissions and general combustion performance. A research version of General Electric Aviation (GE) TAPS injector was used for the tests. Results include 2D, planar laser-based imaging as well as basic flow visualization of the flame. Four conditions were selected that simulate various engine power conditions relevant to NASA Fundamental Aeronautics Supersonics and Environmentally Responsible Aviation Projects were tested.

  20. Is dipyridamole test equivalent to exercise testing for the performing of myocardial tomo-scintigraphy? preliminary results of a systematic comparative analysis in patients having documented episodes of myocardial ischemia

    International Nuclear Information System (INIS)

    David, N.; Quiri, N.; Hassan, N.; Arsena, T.; Py, M.; Olivier, P.; Karcher, G.; Bertrand, A.; Houriez, P.; Grentzinger, A.; Angioi, M.; Danchin, N.; Juilliere, Y.

    1997-01-01

    Dipyridamole test is generally used rather than exercise testing when myocardial tomo-scintigraphy (MTS) is performed with patients unable to perform a maximal exercise test. However, this choice has never been validated by a systematic comparative analysis of the results provided by these two stress techniques with patients having a documented myocardial ischemia. We have included 20 patients who had a known coronary artery disease, for whom exercise test was positive at the time of an exercise MTS-TI201 performed in our department and who underwent an additional MTS-TI201 after intravenous administration of 0,56 mg/kg of dipyridamole and low-level exercise testing (40 W). The extent of perfusion abnormalities, observed after dipyvirdamole, was not significantly different from that evidenced at exercise, even in the analysis restricted to the eight patients who had a sub-maximal test (<80 % of predicted maximal heart rate) at the time of exercise-MTS (% of left ventricle: 17 ± 13 vs 15 ± 8). By contrast, there were important individual variations: a difference in defect-extent (≥ 10 % of left ventricle) was observed between the two tests for 11 patients (55 %), the largest defect being that observed at exercise in six cases, and after dipyridamole in five cases. With patients having exercise myocardial ischemia, the MTS obtained after dipyridamole are frequently very different from those performed after exercise, and the criterion of a low maximal heart rate doses not imply an underestimation of the perfusion abnormalities observed at exercise. (authors)

  1. Cross-Mode Comparability of Computer-Based Testing (CBT) versus Paper-Pencil Based Testing (PPT): An Investigation of Testing Administration Mode among Iranian Intermediate EFL Learners

    Science.gov (United States)

    Khoshsima, Hooshang; Hosseini, Monirosadat; Toroujeni, Seyyed Morteza Hashemi

    2017-01-01

    Advent of technology has caused growing interest in using computers to convert conventional paper and pencil-based testing (Henceforth PPT) into Computer-based testing (Henceforth CBT) in the field of education during last decades. This constant promulgation of computers to reshape the conventional tests into computerized format permeated the…

  2. Comparative Advantage

    DEFF Research Database (Denmark)

    Zhang, Jie; Jensen, Camilla

    2007-01-01

    that are typically explained from the supply-side variables, the comparative advantage of the exporting countries. A simple model is proposed and tested. The results render strong support for the relevance of supply-side factors such as natural endowments, technology, and infrastructure in explaining international...

  3. Policy-Led Comparative Environmental Risk Assessment of Genetically Modified Crops: Testing for Increased Risk Rather Than Profiling Phenotypes Leads to Predictable and Transparent Decision-Making

    Directory of Open Access Journals (Sweden)

    Alan Raybould

    2018-04-01

    Full Text Available We describe two contrasting methods of comparative environmental risk assessment for genetically modified (GM crops. Both are science-based, in the sense that they use science to help make decisions, but they differ in the relationship between science and policy. Policy-led comparative risk assessment begins by defining what would be regarded as unacceptable changes when the use a particular GM crop replaces an accepted use of another crop. Hypotheses that these changes will not occur are tested using existing or new data, and corroboration or falsification of the hypotheses is used to inform decision-making. Science-led comparative risk assessment, on the other hand, tends to test null hypotheses of no difference between a GM crop and a comparator. The variables that are compared may have little or no relevance to any previously stated policy objective and hence decision-making tends to be ad hoc in response to possibly spurious statistical significance. We argue that policy-led comparative risk assessment is the far more effective method. With this in mind, we caution that phenotypic profiling of GM crops, particularly with omics methods, is potentially detrimental to risk assessment.

  4. Test-retest reliability and comparability of paper and computer questionnaires for the Finnish version of the Tampa Scale of Kinesiophobia.

    Science.gov (United States)

    Koho, P; Aho, S; Kautiainen, H; Pohjolainen, T; Hurri, H

    2014-12-01

    To estimate the internal consistency, test-retest reliability and comparability of paper and computer versions of the Finnish version of the Tampa Scale of Kinesiophobia (TSK-FIN) among patients with chronic pain. In addition, patients' personal experiences of completing both versions of the TSK-FIN and preferences between these two methods of data collection were studied. Test-retest reliability study. Paper and computer versions of the TSK-FIN were completed twice on two consecutive days. The sample comprised 94 consecutive patients with chronic musculoskeletal pain participating in a pain management or individual rehabilitation programme. The group rehabilitation design consisted of physical and functional exercises, evaluation of the social situation, psychological assessment of pain-related stress factors, and personal pain management training in order to regain overall function and mitigate the inconvenience of pain and fear-avoidance behaviour. The mean TSK-FIN score was 37.1 [standard deviation (SD) 8.1] for the computer version and 35.3 (SD 7.9) for the paper version. The mean difference between the two versions was 1.9 (95% confidence interval 0.8 to 2.9). Test-retest reliability was 0.89 for the paper version and 0.88 for the computer version. Internal consistency was considered to be good for both versions. The intraclass correlation coefficient for comparability was 0.77 (95% confidence interval 0.66 to 0.85), indicating substantial reliability between the two methods. Both versions of the TSK-FIN demonstrated substantial intertest reliability, good test-retest reliability, good internal consistency and acceptable limits of agreement, suggesting their suitability for clinical use. However, subjects tended to score higher when using the computer version. As such, in an ideal situation, data should be collected in a similar manner throughout the course of rehabilitation or clinical research. Copyright © 2014 Chartered Society of Physiotherapy. Published

  5. Comparison of experimental techniques for measuring fracture toughness of austenitic stainless steels by performance of a comparative round-robin test

    International Nuclear Information System (INIS)

    Huthmann, H.; Akhurst, K.N.; Bethmont, M.; Picker, C.; Rongen, H.J.M. van; Soulat, P.

    1987-01-01

    The CEC fast breeder coordinating committee, activities group 3 Materials of the working group for codes and standards, has recently examined existing data on the fracture toughness of austenitic stainless steels. As a result, the committee decided to sponsor a round robin test programme aimed at comparing experimental techniques and assisting in establishing a standard test method for these steels. The contract for this programme was placed with Interatom, who have subcontracted with CEA-Saclay, CEGB-Leatherhead, TNO-Apeldoorn and UKAEA-Risley. Additionally CISE/ENEL-Milano and EdF-Les Renardieres took part in the round robin. This final report presents a common evaluation and discussion of the results gained by the different laboratories

  6. Biostatistics Series Module 3: Comparing Groups: Numerical Variables.

    Science.gov (United States)

    Hazra, Avijit; Gogtay, Nithya

    2016-01-01

    Numerical data that are normally distributed can be analyzed with parametric tests, that is, tests which are based on the parameters that define a normal distribution curve. If the distribution is uncertain, the data can be plotted as a normal probability plot and visually inspected, or tested for normality using one of a number of goodness of fit tests, such as the Kolmogorov-Smirnov test. The widely used Student's t-test has three variants. The one-sample t-test is used to assess if a sample mean (as an estimate of the population mean) differs significantly from a given population mean. The means of two independent samples may be compared for a statistically significant difference by the unpaired or independent samples t-test. If the data sets are related in some way, their means may be compared by the paired or dependent samples t-test. The t-test should not be used to compare the means of more than two groups. Although it is possible to compare groups in pairs, when there are more than two groups, this will increase the probability of a Type I error. The one-way analysis of variance (ANOVA) is employed to compare the means of three or more independent data sets that are normally distributed. Multiple measurements from the same set of subjects cannot be treated as separate, unrelated data sets. Comparison of means in such a situation requires repeated measures ANOVA. It is to be noted that while a multiple group comparison test such as ANOVA can point to a significant difference, it does not identify exactly between which two groups the difference lies. To do this, multiple group comparison needs to be followed up by an appropriate post hoc test. An example is the Tukey's honestly significant difference test following ANOVA. If the assumptions for parametric tests are not met, there are nonparametric alternatives for comparing data sets. These include Mann-Whitney U-test as the nonparametric counterpart of the unpaired Student's t-test, Wilcoxon signed-rank test

  7. Comparative experiments for tube agglutination test of pullorum antiserum with gamma ray Co/sup 60/ irradiated salmonella pullorum

    Energy Technology Data Exchange (ETDEWEB)

    Seo, B K [City Univ. of Seoul, Seoul (Republic of Korea)

    1976-01-01

    An agglutinability between naturally infected positive chicken serum of pullorum disease and hyperimmunized rabbit antiserum was compared. And the following results were obtained and summarized. On the agglutinability, Salmonella pullorum antigen which irradiated gamma-ray was better than another both formalized and heated antigen. Time of judgemented as positive titer in the tube agglutination test to the naturally infected positive chicken serum was it most suitable for 12 hours at 37/sup 0/C. Agglutination titer of positive immune chicken serum against gamma-ray irradiate Salmonella pullorum were as 320 approximately 640x.

  8. Comparing PETS and GEPT in China and Taiwan

    Science.gov (United States)

    Wu, Mei

    2012-01-01

    This paper compares the Public English Test System (PETS) administered in mainland, China and the General English Proficiency Test (GEPT) administered in Taiwan, from the aspects of test levels, test contents and scoring weight. Compared with the PETS, the GEPT is found to value the English productive skills more, and have a greater ability to…

  9. An interesterified palm olein test meal decreases early-phase postprandial lipemia compared to palm olein:a Randomized Controlled Trial

    OpenAIRE

    Hall, Wendy; Fiuza Brito, Marcela; Huang, Junlan; Wood, Lucy; Filippou, Androulla; Sanders, Thomas A. B.; Berry, Sarah

    2014-01-01

    Palm oil that has been interesterified to produce a higher proportion of palmitic acid (16:0) in the sn-2 position reduces postprandial lipemia in young, normolipidemic men and women, but effects in older subjects with higher fasting triacylglycerol (TAG) concentrations are unknown. We tested the hypothesis that high-fat meals rich in interesterified palm olein (IPO) decrease lipemia and alter plasma lipoprotein fraction composition compared to native palm olein (NPO) in men aged 40–70 years ...

  10. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology.

    Science.gov (United States)

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-07-25

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is blood assay.We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings.In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions.

  11. A time and imaging cost analysis of low-risk ED observation patients: a conservative 64-section computed tomography coronary angiography "triple rule-out" compared to nuclear stress test strategy.

    Science.gov (United States)

    Takakuwa, Kevin M; Halpern, Ethan J; Shofer, Frances S

    2011-02-01

    The study aimed to examine time and imaging costs of 2 different imaging strategies for low-risk emergency department (ED) observation patients with acute chest pain or symptoms suggestive of acute coronary syndrome. We compared a "triple rule-out" (TRO) 64-section multidetector computed tomography protocol with nuclear stress testing. This was a prospective observational cohort study of consecutive ED patients who were enrolled in our chest pain observation protocol during a 16-month period. Our standard observation protocol included a minimum of 2 sets of cardiac enzymes at least 6 hours apart followed by a nuclear stress test. Once a week, observation patients were offered a TRO (to evaluate for coronary artery disease, thoracic dissection, and pulmonary embolus) multidetector computed tomography with the option of further stress testing for those patients found to have evidence of coronary artery disease. We analyzed 832 consecutive observation patients including 214 patients who underwent the TRO protocol. Mean total length of stay was 16.1 hours for TRO patients, 16.3 hours for TRO plus other imaging test, 22.6 hours for nuclear stress testing, 23.3 hours for nuclear stress testing plus other imaging tests, and 23.7 hours for nuclear stress testing plus TRO (P < .0001 for TRO and TRO + other test compared to stress test ± other test). Mean imaging times were 3.6, 4.4, 5.9, 7.5, and 6.6 hours, respectively (P < .05 for TRO and TRO + other test compared to stress test ± other test). Mean imaging costs were $1307 for TRO patients vs $945 for nuclear stress testing. Triple rule-out reduced total length of stay and imaging time but incurred higher imaging costs. A per-hospital analysis would be needed to determine if patient time savings justify the higher imaging costs. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Fatigue crack behaviour: comparing three-point bend test and wedge splitting test data on vibrated concrete using Paris' law

    Czech Academy of Sciences Publication Activity Database

    Seitl, Stanislav; Thienpont, T.; De Corte, W.

    2017-01-01

    Roč. 11, č. 39 (2017), s. 110-117 ISSN 1971-8993 R&D Projects: GA MŠk LM2015069 Institutional support: RVO:68081723 Keywords : Fatigue crack behaviour * Tree-point bending test * Wedge splitting test * Self-compacting concrete Subject RIV: JL - Materials Fatigue, Friction Mechanics OBOR OECD: Audio engineering, reliability analysis

  13. Friction and wear in liquid-metal systems: comparability problems of test results obtained from different test facilities

    International Nuclear Information System (INIS)

    Wild, E.; Mack, K.J.

    1976-01-01

    Operational induced relative movements take place between contacting components in the core region of sodium cooled reactors. To ensure reliable long term functioning of such friction loaded components, materials are needed with good sliding properties and high wear resistance. Therefore, tribological properties of material combinations in liquid metal have been investigated experimentally for many years at various research establishments. However, despite identical boundary conditions, the comparison of results published does not yield a satisfactory agreement. The cause must be seen in the individual design and concept of the test sections used. This discrepancy was investigated. The results show that the elasticity, mass movement, and relative motion characteristic to the system prove to be the most important criteria influencing the test results

  14. Comparative evaluation of bivalent malaria rapid diagnostic tests versus traditional methods in field with special reference to heat stability testing in Central India.

    Directory of Open Access Journals (Sweden)

    Neeru Singh

    Full Text Available Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.This study was undertaken in four forested districts of central India (July, 2011- March, 2012. All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9-98.8 and lowest sensitivity was 76% (95% CI; 71.7-79.6. For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9 and 20% (95% CI; 15.6-24.5 respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6-0.9.This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.

  15. Part III: Comparing observed growth of selected test organisms in food irradiation studies with growth predictions calculated by ComBase softwares

    International Nuclear Information System (INIS)

    Farkas, J.; Andrassy, E.; Meszaros, L.; Beczner, J.; Polyak-Feher, K.; Gaal, O.; Lebovics, V.K.; Lugasi, A.

    2009-01-01

    As a result of intensive predictive microbiological modelling activities, several computer programs and softwares became available recently for facilitating microbiological risk assessment. Among these tools, the establishment of the ComBase, an international database and its predictive modelling softwares of the Pathogen Modelling Program (PMP) set up by the USDA Eastern Regional Research Center, Wyndmore, PA, and the Food Micromodel/Growth Predictor by the United Kingdom's Institute of Food Research, Norwich, are most important. The authors have used the PMP 6.1 software version of ComBase as a preliminary trial to compare observed growth of selected test organisms in relation to their food irradiation work during recent years within the FAO/IAEA Coordinated Food Irradiation Research Projects (D6.10.23 and D6.20.07) with the predicted growth on the basis of growth models available in ComBase for the same species as those of the authors' test organisms. The results of challenge tests with Listeria monocytogenes inoculum in untreated or irradiated experimental batches of semi-prepared breaded turkey meat steaks (cordon bleu), sliced tomato, sliced watermelon, sliced cantaloupe and sous vide processed mixed vegetables, as well as Staphylococcus aureus inoculum of a pasta product, tortellini, were compared with their respective growth models under relevant environmental conditions. This comparison showed good fits in the case of non-irradiated and high moisture food samples, but growth of radiation survivors lagged behind the predicted values. (author)

  16. To test or not to test

    DEFF Research Database (Denmark)

    Rochon, Justine; Gondan, Matthias; Kieser, Meinhard

    2012-01-01

    Background: Student's two-sample t test is generally used for comparing the means of two independent samples, for example, two treatment arms. Under the null hypothesis, the t test assumes that the two samples arise from the same normally distributed population with unknown variance. Adequate...... control of the Type I error requires that the normality assumption holds, which is often examined by means of a preliminary Shapiro-Wilk test. The following two-stage procedure is widely accepted: If the preliminary test for normality is not significant, the t test is used; if the preliminary test rejects...... the null hypothesis of normality, a nonparametric test is applied in the main analysis. Methods: Equally sized samples were drawn from exponential, uniform, and normal distributions. The two-sample t test was conducted if either both samples (Strategy I) or the collapsed set of residuals from both samples...

  17. Comparative ethnobotany and in-the-field antibacterial testing of medicinal plants used by the Bulu and inland Kaulong of Papua New Guinea.

    Science.gov (United States)

    Prescott, Thomas A K; Kiapranis, Robert; Maciver, Sutherland K

    2012-01-31

    The island of New Britain in Papua New Guinea is an area of great floristic and cultural diversity that has received little attention from ethnobotanists. Here we present the results of a comparative medicinal ethnobotanical survey of the Bulu and inland Kaulong; two distinct people groups inhabiting lowland rainforest on different sides of the island. A high proportion of species are used in the treatment of bacterial infections and plants with antibacterial activity were identified in the field using a specially developed antibacterial assay kit. Follow up testing with human pathogens was used to evaluate active plant material in more detail. Rapid appraisal techniques were used to survey both people groups with all data corroborated by three or more separate sources. Plants from both groups were tested in-the-field with a portable antibacterial test kit based on the agar diffusion assay, using a pressure cooker to sterilise glassware and media. Follow up laboratory based tests were carried out using standardised agar dilution protocols for drug resistant and drug sensitive strains of Staphylococcus aureus and Streptococcus pneumoniae. We find surprisingly little overlap in the plant species used by the two people groups with only 1 out of 70 species used for the same purpose. There is also a difference in emphasis in the conditions treated with 53% of Kaulong medicinal plants dedicated to treating tropical ulcers compared with only 8% of in the Bulu group. In-the-field testing identified Garcinia dulcis bark (a Kaulong tropical ulcer treatment) to have antibacterial activity and follow up tests against a drug resistant strain of Staphylococcus aureus (a pathogen implicated in tropical ulcer pathogenesis) revealed the crude bark extract to be potently active with an MIC of just 1 mg/ml. The results demonstrate extreme differences in medicinal plant use between two people groups living a mere 100 km apart and suggests the two medicinal plant systems have developed

  18. Comparative study on novel test systems to determine disintegration time of orodispersible films.

    Science.gov (United States)

    Preis, Maren; Gronkowsky, Dorothee; Grytzan, Dominik; Breitkreutz, Jörg

    2014-08-01

    Orodispersible films (ODFs) are a promising innovative dosage form enabling drug administration without the need for water and minimizing danger of aspiration due to their fast disintegration in small amounts of liquid. This study focuses on the development of a disintegration test system for ODFs. Two systems were developed and investigated: one provides an electronic end-point, and the other shows a transferable setup of the existing disintegration tester for orodispersible tablets. Different ODF preparations were investigated to determine the suitability of the disintegration test systems. The use of different test media and the impact of different storage conditions of ODFs on their disintegration time were additionally investigated. The experiments showed acceptable reproducibility (low deviations within sample replicates due to a clear determination of the measurement end-point). High temperatures and high humidity affected some of the investigated ODFs, resulting in higher disintegration time or even no disintegration within the tested time period. The methods provided clear end-point detection and were applicable for different types of ODFs. By the modification of a conventional test system to enable application for films, a standard method could be presented to ensure uniformity in current quality control settings. © 2014 Royal Pharmaceutical Society.

  19. Comparing the co-evolution of production and test code in open source and industrial developer test processes through repository mining

    NARCIS (Netherlands)

    Van Rompaey, B.; Zaidman, A.E.; Van Deursen, A.; Demeyer, S.

    2008-01-01

    This paper represents an extension to our previous work: Mining software repositories to study coevolution of production & test code. Proceedings of the International Conference on Software Testing, Verification, and Validation (ICST), IEEE Computer Society, 2008; doi:10.1109/ICST.2008.47

  20. Diagnostic tests in Raynaud's phenomena in workers exposed to vibration: a comparative study

    DEFF Research Database (Denmark)

    Olsen, N

    1988-01-01

    Four objective tests to evaluate Raynaud's phenomena (RP) in workers exposed to handarm vibrations were applied on 23 exposed men with RP (vibration induced white finger 18, primary Raynaud's phenomenon 5), 56 exposed men without RP, and 15 male controls. Finger systolic blood pressure was measured...... greater than 0.20). The results indicate that a finger colour test may be as valuable as a FSP(0) test for diagnostic purposes. FSP(A) only indicates if a cold response is exaggerated and does not diagnose RP. The pressure measurements may further be of guidance in evaluating preventive measures...... by a cuff and strain gauge technique after combined body cooling and finger cooling during five minute ischaemia to 30 degrees, 15 degrees, and 6 degrees C. An attack of RP was detected as a zero pressure, FSP(0) test, whereas a pressure, reduced to a value below the normal 95% confidence limit at 6 degrees...

  1. Kolmogorov-Smirnov statistical test for analysis of ZAP-70 expression in B-CLL, compared with quantitative PCR and IgV(H) mutation status.

    Science.gov (United States)

    Van Bockstaele, Femke; Janssens, Ann; Piette, Anne; Callewaert, Filip; Pede, Valerie; Offner, Fritz; Verhasselt, Bruno; Philippé, Jan

    2006-07-15

    ZAP-70 has been proposed as a surrogate marker for immunoglobulin heavy-chain variable region (IgV(H)) mutation status, which is known as a prognostic marker in B-cell chronic lymphocytic leukemia (CLL). The flow cytometric analysis of ZAP-70 suffers from difficulties in standardization and interpretation. We applied the Kolmogorov-Smirnov (KS) statistical test to make analysis more straightforward. We examined ZAP-70 expression by flow cytometry in 53 patients with CLL. Analysis was performed as initially described by Crespo et al. (New England J Med 2003; 348:1764-1775) and alternatively by application of the KS statistical test comparing T cells with B cells. Receiver-operating-characteristics (ROC)-curve analyses were performed to determine the optimal cut-off values for ZAP-70 measured by the two approaches. ZAP-70 protein expression was compared with ZAP-70 mRNA expression measured by a quantitative PCR (qPCR) and with the IgV(H) mutation status. Both flow cytometric analyses correlated well with the molecular technique and proved to be of equal value in predicting the IgV(H) mutation status. Applying the KS test is reproducible, simple, straightforward, and overcomes a number of difficulties encountered in the Crespo-method. The KS statistical test is an essential part of the software delivered with modern routine analytical flow cytometers and is well suited for analysis of ZAP-70 expression in CLL. (c) 2006 International Society for Analytical Cytology.

  2. Ferritin Test

    Science.gov (United States)

    ... normal" values. By comparing your test results with reference values, you and your healthcare provider can see if ... along with other iron tests , when a routine complete blood count (CBC) shows that a person's hemoglobin and hematocrit ...

  3. Comparing contracting performance

    DEFF Research Database (Denmark)

    Lindholst, Andrej Christian

    . Hypotheses are suggested for the role of culture, competition, contracts, capabilities and collaboration for contracting performance between and across the countries. Arguments are tested against data from on four comparable national surveys of private delivery of park and road maintenance services in local...

  4. Impact of streptozotocin on altering normal glucose homeostasis during insulin testing in diabetic rats compared to normoglycemic rats

    Directory of Open Access Journals (Sweden)

    Qinna NA

    2015-05-01

    Full Text Available Nidal A Qinna,1 Adnan A Badwan2 1Department of Pharmacology and Biomedical Sciences, Faculty of Pharmacy and Medical Sciences, University of Petra, 2Research and Innovation Centre, The Jordanian Pharmaceutical Manufacturing Co. Plc. (JPM, Amman, Jordan Abstract: Streptozotocin (STZ is currently the most used diabetogenic agent in testing insulin and new antidiabetic drugs in animals. Due to the toxic and disruptive nature of STZ on organs, apart from pancreas, involved in preserving the body’s normal glucose homeostasis, this study aims to reassess the action of STZ in inducing different glucose response states in diabetic rats while testing insulin. Diabetic Sprague-Dawley rats induced with STZ were classified according to their initial blood glucose levels into stages. The effect of randomizing rats in such a manner was investigated for the severity of interrupting normal liver, pancreas, and kidney functions. Pharmacokinetic and pharmacodynamic actions of subcutaneously injected insulin in diabetic and nondiabetic rats were compared. Interruption of glucose homeostasis by STZ was challenged by single and repeated administrations of injected insulin and oral glucose to diabetic rats. In diabetic rats with high glucose (451–750 mg/dL, noticeable changes were seen in the liver and kidney functions compared to rats with lower basal glucose levels. Increased serum levels of recombinant human insulin were clearly indicated by a significant increase in the calculated maximum serum concentration and area under the concentration–time curve. Reversion of serum glucose levels to normal levels pre- and postinsulin and oral glucose administrations to STZ diabetic rats were found to be variable. In conclusion, diabetic animals were more responsive to insulin than nondiabetic animals. STZ was capable of inducing different levels of normal glucose homeostasis disruption in rats. Both pharmacokinetic and pharmacodynamic actions of insulin were

  5. Towards a Comparative and International History of School Testing and Accountability

    Science.gov (United States)

    Dorn, Sherman; Ydesen, Christian

    2014-01-01

    The speed and extent of modern school accountability have obscured the history of testing and accountability. This brief introduction identifies central themes of historical research into educational accountability and recurring traits associated with accountability practices. We hope our colleagues and this special issue will also help to…

  6. Comparative testing of dark matter models with 15 HSB and 15 LSB galaxies

    Science.gov (United States)

    Kun, E.; Keresztes, Z.; Simkó, A.; Szűcs, G.; Gergely, L. Á.

    2017-12-01

    Context. We assemble a database of 15 high surface brightness (HSB) and 15 low surface brightness (LSB) galaxies, for which surface brightness density and spectroscopic rotation curve data are both available and representative for various morphologies. We use this dataset to test the Navarro-Frenk-White, the Einasto, and the pseudo-isothermal sphere dark matter models. Aims: We investigate the compatibility of the pure baryonic model and baryonic plus one of the three dark matter models with observations on the assembled galaxy database. When a dark matter component improves the fit with the spectroscopic rotational curve, we rank the models according to the goodness of fit to the datasets. Methods: We constructed the spatial luminosity density of the baryonic component based on the surface brightness profile of the galaxies. We estimated the mass-to-light (M/L) ratio of the stellar component through a previously proposed color-mass-to-light ratio relation (CMLR), which yields stellar masses independent of the photometric band. We assumed an axissymetric baryonic mass model with variable axis ratios together with one of the three dark matter models to provide the theoretical rotational velocity curves, and we compared them with the dataset. In a second attempt, we addressed the question whether the dark component could be replaced by a pure baryonic model with fitted M/L ratios, varied over ranges consistent with CMLR relations derived from the available stellar population models. We employed the Akaike information criterion to establish the performance of the best-fit models. Results: For 7 galaxies (2 HSB and 5 LSB), neither model fits the dataset within the 1σ confidence level. For the other 23 cases, one of the models with dark matter explains the rotation curve data best. According to the Akaike information criterion, the pseudo-isothermal sphere emerges as most favored in 14 cases, followed by the Navarro-Frenk-White (6 cases) and the Einasto (3 cases) dark

  7. A Comparative Investigation into Understandings and Uses of the "TOEFL iBT"® Test, the International English Language Testing Service (Academic) Test, and the Pearson Test of English for Graduate Admissions in the United States and Australia: A Case Study of Two University Contexts. "TOEFL iBT"® Research Report. TOEFL iBT-24. ETS Research Report. RR-14-44

    Science.gov (United States)

    Ginther, April; Elder, Catherine

    2014-01-01

    In line with expanded conceptualizations of validity that encompass the interpretations and uses of test scores in particular policy contexts, this report presents results of a comparative analysis of institutional understandings and uses of 3 international English proficiency tests widely used for tertiary selection--the "TOEFL iBT"®…

  8. P2-29: Comparing the Other-Race-Effect and Congenital Prosopagnosia Using a Three-Experiment Test Battery

    Directory of Open Access Journals (Sweden)

    Janina Esins

    2012-10-01

    Full Text Available Congenital prosopagnosia, an innate impairment in recognizing faces, as well as the other-race-effect, the disadvantage in recognizing faces of foreign races, both influence face recognition abilities. Here we compared both phenomena by testing three groups: German congenital prosopagnosics (cPs, unimpaired German, and unimpaired South Korean participants (n = 23 per group, on three tests with Caucasian faces. First we ran the Cambridge Face Memory Test (Duchaine & Nakayama, 2006 Neuropsychologia 44 576–585. Participants had to recognize Caucasian target faces in a 3AFC task. German controls performed better than Koreans (p = .009 who performed better than prosopagnosics (p = .0001. Variation of the individual performances was larger for cPs than for Koreans (p = .028. In the second experiment, participants rated the similarity of Caucasian faces (in-house 3D face-database which differed parametrically in features or second order relations (configuration. We found differences between sensitivities to change type (featural or configural, p = 0 and between groups (p = .005 and an interaction between both factors (p = .019. During the third experiment, participants had to learn exemplars of artificial objects (greebles, natural objects (shells, and faces and recognize them among distractors. The results showed an interaction (p = .005 between stimulus type and participant group: cPs where better for non-face stimuli and worse for face stimuli than the other groups. Our results suggest that congenital prosopagnosia and the other-race-effect affect face perception in different ways. The broad range in performance for the cPs directs the focus of our future research towards looking for different forms of congenital prosopagnosia.

  9. Comparing two methods of education (virtual versus traditional) on learning of Iranian dental students: a post-test only design study.

    Science.gov (United States)

    Moazami, Fariborz; Bahrampour, Ehsan; Azar, Mohammad Reza; Jahedi, Farzad; Moattari, Marzieh

    2014-03-05

    The importance of using technologies such as e-learning in different disciplines is discussed in the literature. Researchers have measured the effectiveness of e-learning in a number of fields.Considering the lack of research on the effectiveness of online learning in dental education particularly in Iran, the advantages of these learning methods and the positive university atmosphere regarding the use of online learning. This study, therefore, aims to compare the effects of two methods of teaching (virtual versus traditional) on student learning. This post-test only design study approached 40, fifth year dental students of Shiraz University of Medical Sciences. From this group, 35 students agreed to participate. These students were randomly allocated into two groups, experimental (virtual learning) and comparison (traditional learning). To ensure similarity between groups, we compared GPAs of all participants by the Mann-Whitney U test (P > 0.05). The experimental group received a virtual learning environment courseware package specifically designed for this study, whereas the control group received the same module structured in a traditional lecture form. The virtual learning environment consisted of online and offline materials. Two identical valid, reliable post-tests that consisted of 40 multiple choice questions (MCQs) and 4 essay questions were administered immediately (15 min) after the last session and two months later to assess for knowledge retention. Data were analyzed by SPSS version 20. A comparison of the mean knowledge score of both groups showed that virtual learning was more effective than traditional learning (effect size = 0.69). The newly designed virtual learning package is feasible and will result in more effective learning in comparison with lecture-based training. However further studies are needed to generalize the findings of this study.

  10. Road and rail traffic noise induce comparable extra-aural effects as revealed during a short-term memory test

    Directory of Open Access Journals (Sweden)

    Eugen Gallasch

    2016-01-01

    Full Text Available To examine extraaural effects as induced by 20 min of road (ROAD and 20 min of rail (RAIL traffic noise with same loudness (75 dBA, a laboratory study was carried out. The study (N = 54 consisted of 28 high and 26 low-annoyed healthy individuals as determined by a traffic annoyance test. To control attention, all individuals performed a nonauditory short-term memory test during the noise exposures. A within-subject design, with phases of ROAD, RAIL, and CALM (memory test only, alternated by phases of rest, was defined. Heart rate (HR, systolic blood pressure (sBP, total peripheral resistance (TPR, as well as three autonomic variables, preejection period (PEP, 0.15–0.4 Hz high-frequency component of HR variability (HF, and salivary stress biomarker alpha amylase (sAA were measured. In relation to CALM, HR increased (RAIL +2.1%, ROAD +2.5%, sBP tended to increase against the end of noise exposure, PEP decreased (RAIL −0.7%, ROAD −0.8%, HF decreased (RAIL −3.4%, ROAD −2.9%, and sAA increased (RAIL +78%, ROAD +69%. No differences were found between RAIL and ROAD, indicating that both noise stressors induced comparable extraaural effects. Factor annoyance showed significant during CALM. Here a reduced sympathetic drive (higher PEP values combined with an increased vascular tone (higher TPR values was found at the high-annoyed subgroup.

  11. The Effect of Mini and Midi Anchor Tests on Test Equating

    Science.gov (United States)

    Arikan, Çigdem Akin

    2018-01-01

    The main purpose of this study is to compare the test forms to the midi anchor test and the mini anchor test performance based on item response theory. The research was conducted with using simulated data which were generated based on Rasch model. In order to equate two test forms the anchor item nonequivalent groups (internal anchor test) was…

  12. Safety and efficacy of the C-Tb skin test to diagnose Mycobacterium tuberculosis infection, compared with an interferon γ release assay and the tuberculin skin test: a phase 3, double-blind, randomised, controlled trial.

    Science.gov (United States)

    Ruhwald, Morten; Aggerbeck, Henrik; Gallardo, Rafael Vázquez; Hoff, Søren T; Villate, José I; Borregaard, Bettine; Martinez, José A; Kromann, Ingrid; Penas, Antón; Anibarro, Luis L; de Souza-Galvão, Maria Luiza; Sánchez, Francisca; Rodrigo-Pendás, Jose Ángel; Noguera-Julian, Antoni; Martínez-Lacasa, Xavier; Tuñez, Maria Victoria; Fernández, Virginia Leiro; Millet, Joan P; Moreno, Antonio; Cobos, Nazaret; Miró, José M; Roldan, Llanos; Orcau, Angels; Andersen, Peter; Caylá, Joan A

    2017-04-01

    Targeted screening and treatment of Mycobacterium tuberculosis infection substantially reduces the risk of developing active tuberculosis. C-Tb (Statens Serum Institute, Copenhagen, Denmark) is a novel specific skin test based on ESAT-6 and CFP10 antigens. We investigated the safety and diagnostic potential of C-Tb compared with established tests in the contact-tracing setting. Negative controls, close contacts, occasional contacts, and patients with active pulmonary tuberculosis were enrolled at 13 centres in Spain. We compared C-Tb with the QuantiFERON-TB Gold In-Tube ([QFT] Qiagen, Hilden, Germany) interferon γ release assay (IGRA) and the purified protein derivative (PPD) RT 23 tuberculin skin test ([TST] Statens Serum Institute). All participants older than 5 years were tested with QFT. Some participants in the negative control group received C-Tb without the TST to test for potential interactions between C-Tb and PPD RT 23. The rest were randomly assigned in blocks of ten and tested with both C-Tb and TST, with five in each block receiving injection of C-Tb in the right arm and the TST in the left arm and five vice versa. The primary and safety analyses were done in all participants randomly assigned to a group who received any test. This trial is registered with ClinicalTrials.gov, number NCT01631266, and with EudraCT, number 2011-005617-36. From July 24, 2012, to Oct 2, 2014, 979 participants were enrolled, of whom 263 were negative controls, 299 were occasional contacts, 316 were close contacts, and 101 were patients with tuberculosis. 970 (99%) participants completed the trial. Induration sizes were similar for C-Tb and TST, but TST positivity was affected by BCG vaccination status. We found a strong positive trend towards C-Tb test positivity with increasing risk of infection, from 3% in negative controls to 16% in occasional contacts, to 43% in close contacts. C-Tb and QFT results were concordant in 785 (94%) of 834 participants aged 5 years and older

  13. Comparing Two Tests of Formal Reasoning in a College Chemistry Context

    Science.gov (United States)

    Jiang, Bo; Xu, Xiaoying; Garcia, Alicia; Lewis, Jennifer E.

    2010-01-01

    The Test of Logical Thinking (TOLT) and the Group Assessment of Logical Thinking (GALT) are two of the instruments most widely used by science educators and researchers to measure students' formal reasoning abilities. Based on Piaget's cognitive development theory, formal thinking ability has been shown to be essential for student achievement in…

  14. Digface characterization test plan (remote testing)

    International Nuclear Information System (INIS)

    Croft, K.; Hyde, R.; Allen, S.

    1993-08-01

    The objective of the Digface Characterization (DFC) Remote Testing project is to remotely deploy a sensor head (Mini-Lab) across a digface to determine if it can characterize the contents below the surface. The purpose of this project is to provide a robotics technology that allows removal of workers from hazards, increases speed of operations, and reduces life cycle costs compared to alternate methods and technologies. The Buried Waste Integrated Demonstration (BWID) is funding the demonstration, testing, and evaluation of DFC. This document describes the test plan for the DFC remote deployment demonstration for the BWID. The purposes of the test plan are to establish test parameters so that the demonstration results are deemed useful and usable and perform the demonstration in a safe manner and within all regulatory requirements

  15. Effects of Repeated Testing on Short- and Long-Term Memory Performance across Different Test Formats

    Science.gov (United States)

    Stenlund, Tova; Sundström, Anna; Jonsson, Bert

    2016-01-01

    This study examined whether practice testing with short-answer (SA) items benefits learning over time compared to practice testing with multiple-choice (MC) items, and rereading the material. More specifically, the aim was to test the hypotheses of "retrieval effort" and "transfer appropriate processing" by comparing retention…

  16. A Kolmogorov-Smirnov Based Test for Comparing the Predictive Accuracy of Two Sets of Forecasts

    Directory of Open Access Journals (Sweden)

    Hossein Hassani

    2015-08-01

    Full Text Available This paper introduces a complement statistical test for distinguishing between the predictive accuracy of two sets of forecasts. We propose a non-parametric test founded upon the principles of the Kolmogorov-Smirnov (KS test, referred to as the KS Predictive Accuracy (KSPA test. The KSPA test is able to serve two distinct purposes. Initially, the test seeks to determine whether there exists a statistically significant difference between the distribution of forecast errors, and secondly it exploits the principles of stochastic dominance to determine whether the forecasts with the lower error also reports a stochastically smaller error than forecasts from a competing model, and thereby enables distinguishing between the predictive accuracy of forecasts. We perform a simulation study for the size and power of the proposed test and report the results for different noise distributions, sample sizes and forecasting horizons. The simulation results indicate that the KSPA test is correctly sized, and robust in the face of varying forecasting horizons and sample sizes along with significant accuracy gains reported especially in the case of small sample sizes. Real world applications are also considered to illustrate the applicability of the proposed KSPA test in practice.

  17. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  18. The comparison of the unit test tools JUnit and TestNG

    OpenAIRE

    Šarkanj, Aleš

    2011-01-01

    Testing holds an important role in developing software. It is a process ensuring software works as expected. An important part of testing is unit testing as the basic testing level. The purpose of this thesis is comparing JUnit and TestNG, two of the most popular unit testing tools in Java. In the first part we will present testing and its purpose within software development. We will also present the basic terminology and levels of testing. Further on the area of unit testing will be pr...

  19. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-01-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646

  20. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics.

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-12-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen's size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics.

  1. Testing Significance Testing

    Directory of Open Access Journals (Sweden)

    Joachim I. Krueger

    2018-04-01

    Full Text Available The practice of Significance Testing (ST remains widespread in psychological science despite continual criticism of its flaws and abuses. Using simulation experiments, we address four concerns about ST and for two of these we compare ST’s performance with prominent alternatives. We find the following: First, the 'p' values delivered by ST predict the posterior probability of the tested hypothesis well under many research conditions. Second, low 'p' values support inductive inferences because they are most likely to occur when the tested hypothesis is false. Third, 'p' values track likelihood ratios without raising the uncertainties of relative inference. Fourth, 'p' values predict the replicability of research findings better than confidence intervals do. Given these results, we conclude that 'p' values may be used judiciously as a heuristic tool for inductive inference. Yet, 'p' values cannot bear the full burden of inference. We encourage researchers to be flexible in their selection and use of statistical methods.

  2. The comparative analysis of model and prototype test results of Bulb turbine

    International Nuclear Information System (INIS)

    Benisek, M; Bozic, I; Ignjatovic, B

    2010-01-01

    This paper presents the problem of the hydropower plant oblique water inflow and its influence on the turbines operation. Oblique water inflow on the low head hydropower plant with bulb turbines influences turbine characteristics. The characteristics change occurs due to swirl incidence in the turbine inlet which spreads to the guide vanes inlet. Downstream, the flow conditions change is caused in the turbine runner in relation to the flow conditions without swirl inflow. Special attention is paid to the phenomenon of swirl flow incidence in the turbine conduit. With the aim of presenting and analyzing the oblique water inflow consequences on the hydropower plant operation, the existing turbine model tests results, performed in the laboratories, and the in situ prototype testing results have been used.

  3. Prenatal developmental toxicity testing of petroleum substances: Application of the mouse embryonic stem cell test (EST) to compare in vitro potencies with potencies observed in vivo.

    Science.gov (United States)

    Kamelia, Lenny; Louisse, Jochem; de Haan, Laura; Rietjens, Ivonne M C M; Boogaard, Peter J

    2017-10-01

    Prenatal developmental toxicity (PDT) as observed with some petroleum substances (PS) has been associated with the presence of 3-7 ring polycyclic aromatic hydrocarbons (PAHs). In the present study, the applicability of ES-D3 cell differentiation assay of the EST to evaluate in vitro embryotoxicity potencies of PS and gas-to-liquid (GTL) products as compared to their in vivo potencies was investigated. DMSO-extracts of a range of PS, containing different amounts of PAHs, and GTL-products, which are devoid of PAHs, were tested in the ES-D3 cell proliferation and differentiation assays of the EST. The results show that PS inhibited the differentiation of ES-D3 cells into cardiomyocytes in a concentration-dependent manner at non-cytotoxic concentrations, and that their potency was proportional to their PAH content. In contrast, as expected, GTL-products did not inhibit ES-D3 cell viability or differentiation at all. The in vitro PDT potencies were compared to published in vivo PDT studies, and a good correlation was found between in vitro and in vivo results (R 2 =0.97). To conclude, our results support the hypothesis that PAHs are the primary inducers of the PDT in PS. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Comparing Types of Financial Incentives to Promote Walking: An Experimental Test.

    Science.gov (United States)

    Burns, Rachel J; Rothman, Alexander J

    2018-04-19

    Offering people financial incentives to increase their physical activity is an increasingly prevalent intervention strategy. However, little is known about the relative effectiveness of different types of incentives. This study tested whether incentives based on specified reinforcement types and schedules differentially affected the likelihood of meeting a walking goal and explored if observed behavioural changes may have been attributable to the perceived value of the incentive. A 2 (reinforcement type: cash reward, deposit contract) × 2 (schedule: fixed, variable) between-subjects experiment with a hanging control condition was conducted over 8 weeks (n = 153). Although walking was greater in the incentive conditions relative to the control condition, walking did not differ across incentive conditions. Exploratory analyses indicated that the perceived value of the incentive was associated with the likelihood of meeting the walking goal, but was not affected by reinforcement type or schedule. The reinforcement type and schedule manipulations tested in this study did not differentially affect walking. Given that walking behaviour was associated with perceived value, designing incentive strategies that optimise the perceived value of the incentive may be a promising avenue for future research. © 2018 The International Association of Applied Psychology.

  5. Asphalt Mixture Fatigue Testing : Influence of Test Type and Specimen Size

    NARCIS (Netherlands)

    Li, N.

    2013-01-01

    Fatigue characterization of an asphalt mixture is commonly estimated by laboratory fatigue tests. Based on the classical fatigue analysis, fatigue lives obtained from different test devices are not comparable even when they are performed at the same test conditions. It is believed that there are two

  6. In-home versus laboratory sensory testing using non-expert consumers: A comparable study using testing of varieties of Danish strawberries as cases

    DEFF Research Database (Denmark)

    Østergaard, Peder

    varieties of strawberries, which are able to satisfy both consumer and producer demands, in which both testing approaches have been used. As part of the project the following methodological steps were taken in order to identify consumer preferences for strawberries: focus group interviews aiming at finding...... the relevant question for a large scale survey among Danish households (n=1162), showing the households general knowledge, attitudes and behaviour when buying and consuming strawberries. From this large scale survey n=120 persons were randomly selected for participation in experiments, where 9 new varieties...... and 2 well-known varieties of strawberries were tested. The testing used a split-over design where each person participated in sensory testing of 5 different varieties of strawberries. Besides all the participant in the experiment were asked to do an in-home test of 2 of the 5 varieties of strawberries...

  7. Comparing treatment effects of oral THC on simulated and on-the-road driving performance: testing the validity of driving simulator drug research.

    Science.gov (United States)

    Veldstra, J L; Bosker, W M; de Waard, D; Ramaekers, J G; Brookhuis, K A

    2015-08-01

    The driving simulator provides a safe and controlled environment for testing driving behaviour efficiently. The question is whether it is sensitive to detect drug-induced effects. The primary aim of the current study was to investigate the sensitivity of the driving simulator for detecting drug effects. As a case in point, we investigated the dose-related effects of oral ∆(9)-tetrahydrocannabinol (THC), i.e. dronabinol, on simulator and on-the-road driving performance in equally demanding driving tasks. Twenty-four experienced driver participants were treated with dronabinol (Marinol®; 10 and 20 mg) and placebo. Dose-related effects of the drug on the ability to keep a vehicle in lane (weaving) and to follow the speed changes of a lead car (car following) were compared within subjects for on-the-road versus in-simulator driving. Additionally, the outcomes of equivalence testing to alcohol-induced effects were investigated. Treatment effects found on weaving when driving in the simulator were comparable to treatment effects found when driving on the road. The effect after 10 mg dronabinol was however less strong in the simulator than on the road and inter-individual variance seemed higher in the simulator. There was, however, a differential treatment effect of dronabinol on reactions to speed changes of a lead car (car following) when driving on the road versus when driving in the simulator. The driving simulator was proven to be sensitive for demonstrating dronabinol-induced effects particularly at higher doses. Treatment effects of dronabinol on weaving were comparable with driving on the road but inter-individual variability seemed higher in the simulator than on the road which may have potential effects on the clinical inferences made from simulator driving. Car following on the road and in the simulator were, however, not comparable.

  8. Testing a Personal Narrative for Persuading People to Value and Use Comparative Physician Quality of Care Information: An Experimental Study.

    Science.gov (United States)

    Greene, Jessica; Hibbard, Judith H; Sacks, Rebecca M

    2017-09-01

    This study tests whether a personal narrative can persuade people to value comparative data on physician quality. We conducted an online experiment with 850 adults. One group viewed a cartoon narrative on physician quality variation, another saw text on physician quality variation, and there was a control group. Study participants hypothetically selected a physician from a display of four physicians. The top-quality physician was furthest away and most expensive. We conducted multivariate models examining the relationship between experimental group and choice of the top-quality physician. There was no overall relationship between narrative or text information and choice of the highest quality physician. Among higher numerate participants, however, those who viewed the narrative had odds 2.7 times higher of selecting the top-quality physician compared with the control group. Personal narratives can persuade higher numerate people to consider quality when selecting physicians.

  9. Studies on Hepa filter test methods

    International Nuclear Information System (INIS)

    Lee, S.H.; Jon, K.S.; Park, W.J.; Ryoo, R.

    1981-01-01

    The purpose of this study is to compare testing methods of the HEPA filter adopted in other countries with each other, and to design and construct a test duct system to establish testing methods. The American D.O.P. test method, the British NaCl test method and several other independently developed methods are compared. It is considered that the D.O.P. method is most suitable for in-plant and leak tests

  10. Performance of two Aspergillus IgG EIA assays compared with the precipitin test in chronic and allergic aspergillosis.

    Science.gov (United States)

    Baxter, C G; Denning, D W; Jones, A M; Todd, A; Moore, C B; Richardson, M D

    2013-04-01

    Detection of Aspergillus IgG antibodies is important in the diagnosis of chronic pulmonary aspergillosis and allergic bronchopulmonary aspergillosis. Immunoprecipitation techniques to detect these antibodies appear to lack sensitivity and accurate quantitation compared with enzyme immunoassays (EIA). This study assessed the performance of two commercial EIAs compared with counterimmunoelectrophoresis (CIE). This was a prospective cohort study of 175 adult patients with chronic or allergic pulmonary aspergillosis. Aspergillus IgG antibodies were detected using CIE, Phadia ImmunoCap Aspergillus IgG and Bio-Rad Platelia Aspergillus IgG. Inter-assay reproducibility was determined for each method and 25 patients had two serum samples analysed within a 6-month interval. When compared with CIE, both ImmunoCap and Platelia Aspergillus IgG had good sensitivity (97 and 93%, respectively) for detection of Aspergillus IgG antibodies. The level of agreement between the two EIAs for positive results was good, but the concentration of antibodies was not correlated between the tests or with CIE titre. ImmunoCap IgG inter-assay coefficient of variation was 5%, whereas Platelia IgG was 33%. Median ImmunoCap IgG values for CPA and allergic aspergillosis were 95 and 32 mg/L, respectively, whereas Platelia IgG values were >80 and 6 AU/mL. The direction of CIE titre change over 6 months was mirrored by ImmunoCap IgG levels in 92% of patients, and by Platelia IgG in 72% of patients. Both ImmunoCap and Platelia Aspergillus IgG EIAs are sensitive measures of Aspergillus IgG antibodies compared with CIE. However, ImmunoCap appears to have better reproducibility and may be more suitable for monitoring patient disease. © 2012 The Authors Clinical Microbiology and Infection © 2012 European Society of Clinical Microbiology and Infectious Diseases.

  11. Comparative Study of Load Testing Tools: Apache JMeter, HP LoadRunner, Microsoft Visual Studio (TFS, Siege

    Directory of Open Access Journals (Sweden)

    Rabiya Abbas

    2017-12-01

    Full Text Available Software testing is the process of verifying and validating the user’s requirements. Testing is ongoing process during whole software development. Software testing is characterized into three main types. That is, in Black box testing, user doesn’t know domestic knowledge, internal logics and design of system. In white box testing, Tester knows the domestic logic of code. In Grey box testing, Tester has little bit knowledge about the internal structure and working of the system. It is commonly used in case of Integration testing.Load testing helps us to analyze the performance of the system under heavy load or under Zero load. This is achieved with the help of a Load Testing Tool. The intention for writing this research is to carry out a comparison of four load testing tools i.e. Apache JMeter, LoadRunner, Microsoft Visual Studio (TFS, Siege based on certain criteria  i.e. test scripts generation , result reports, application support, plug-in supports, and cost . The main focus is to study these load testing tools and identify which tool is better and more efficient . We assume this comparison can help in selecting the most appropriate tool and motivates the use of open source load testing tools.

  12. Testing After Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    NARCIS (Netherlands)

    T.A.J.M. van Gog (Tamara); L. Kester (Liesbeth); K. Dirkx (Kim); V. Hoogerheide (Vincent); J. Boerboom (Joris); P.P.J.L. Verkoeijen (Peter)

    2015-01-01

    textabstractFour experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n = 120) showed no beneficial effects of testing consisting of isomorphic problem solving or example recall on final test performance,

  13. Testing After Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    NARCIS (Netherlands)

    Van Gog, Tamara; Kester, Liesbeth; Dirkx, Kim; Hoogerheide, Vincent; Boerboom, Joris; Verkoeijen, Peter P. J. L.

    2016-01-01

    Four experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n=120) showed no beneficial effects of testing consisting of isomorphic problem solving or example recall on final test performance, which

  14. Testing After Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    NARCIS (Netherlands)

    van Gog, Tamara; Kester, Liesbeth; Dirkx, Kim; Hoogerheide, Vincent; Boerboom, Joris; Verkoeijen, Peter P J L

    Four experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n = 120) showed no beneficial effects of testing consisting of isomorphic problem solving or example recall on final test performance, which

  15. Fluid dispersal from safety cannulas: an in vitro comparative test.

    Science.gov (United States)

    Rosenthal, Victor D; Hughes, Gavin

    2015-03-01

    We report a comparative laboratory study between 2 peripheral intravenous catheters equipped with a passive fully automatic safety mechanism to assess generation of blood droplets during withdrawal. One presented no fluid droplets, whereas the other presented droplets in 48% and 60% for the best and worst case, with analysis of variance showing positive effects on the number of droplets generated (P blood splatter. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Comparing flowmeter, aquifer test, and surface nuclear magnetic resonance data in Central Nebraska

    Science.gov (United States)

    Irons, T.; Abraham, J. D.; Cannia, J. C.; Steele, G.; Hobza, C. M.; Li, Y.; McKenna, J. R.

    2011-12-01

    Traditionally the only means of estimating the hydraulic properties of aquifers has involved drilling boreholes. The logistical and economic requirements of aquifer tests has limited the ability of hydrologists to construct the detailed groundwater models needed for resource management. As such, water policy decisions are often based on sparse aquifer tests combined with geologic interpretation and extrapolation. When dealing with complicated groundwater systems these extrapolations are often not accurate at the scale required to characterize the groundwater system, and additional information is needed to make better informed resource decisions. Surface nuclear magnetic resonance (SNMR) is a geophysical technique which allows for non-invasive estimates of hydraulic permeability and transmissivity. Protons in a volume of liquid water form a weak bulk magnetic moment as they align and precess about the earth's magnetic field. This moment is too small to be measured directly but may be observed by tipping it away from equilibrium using radio-frequency pulses oscillating at the same frequency as its precession (the Larmor frequency). After a short tipping pulse, the moment continues to precess around the static field, although at a tipped angle, slowly returning to its equilibrium state. The decay of these spinning magnetic moments can be observed inductively using loops of wire on the surface of the earth. In the simplest experiment a time series is recorded after a single tipping pulse. By varying the strength of the tipping pulse, different regions of the subsurface can be probed. The amplitude of the signal is directly proportional to the amount of water in the investigated volume. The decay rate of the signal is related to pore geometry and interconnectivity and can be used to estimate hydraulic conductivity. However, this relationship cannot be universally defined as it is affected by additional factors including the mineralogy of the host rock and homogeneity of

  17. Testing after Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    Science.gov (United States)

    van Gog, Tamara; Kester, Liesbeth; Dirkx, Kim; Hoogerheide, Vincent; Boerboom, Joris; Verkoeijen, Peter P. J. L.

    2015-01-01

    Four experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n?=?120) showed no beneficial effects of testing consisting of "isomorphic" problem solving or "example recall" on final test performance, which consisted of isomorphic problem…

  18. The testing effect for mediator final test cues and related final test cues in online and laboratory experiments.

    Science.gov (United States)

    Coppens, Leonora C; Verkoeijen, Peter P J L; Bouwmeester, Samantha; Rikers, Remy M J P

    2016-05-31

    The testing effect is the finding that information that is retrieved during learning is more often correctly retrieved on a final test than information that is restudied. According to the semantic mediator hypothesis the testing effect arises because retrieval practice of cue-target pairs (mother-child) activates semantically related mediators (father) more than restudying. Hence, the mediator-target (father-child) association should be stronger for retrieved than restudied pairs. Indeed, Carpenter (2011) found a larger testing effect when participants received mediators (father) than when they received target-related words (birth) as final test cues. The present study started as an attempt to test an alternative account of Carpenter's results. However, it turned into a series of conceptual (Experiment 1) and direct (Experiment 2 and 3) replications conducted with online samples. The results of these online replications were compared with those of similar existing laboratory experiments through small-scale meta-analyses. The results showed that (1) the magnitude of the raw mediator testing effect advantage is comparable for online and laboratory experiments, (2) in both online and laboratory experiments the magnitude of the raw mediator testing effect advantage is smaller than in Carpenter's original experiment, and (3) the testing effect for related cues varies considerably between online experiments. The variability in the testing effect for related cues in online experiments could point toward moderators of the related cue short-term testing effect. The raw mediator testing effect advantage is smaller than in Carpenter's original experiment.

  19. The concise cognitive test for dementia screening: reliability and effects of demographic variables as compared to the mini mental state examination.

    Science.gov (United States)

    Srinivasan, Srikanth

    2010-01-01

    The Mini Mental State Examination (MMSE) is widely used for dementia screening but has several shortcomings such as prominent ceiling effects, inadequate sensitivity to mild cognitive impairment, and uneven sampling of the major cognitive domains. In this study, we pilot a new dementia screening test - the Concise Cognitive Test (CONCOG) - designed to overcome the above short comings and describe the reliability measures and age, education, and gender effects. The CONCOG has a total score of 30, and has subtests for orientation, naming, registration, free recall and recognition of four words, semantic verbal fluency and copying. Participants were screened to exclude those with any neurological or psychiatric disease, simultaneously administered the CONCOG, and a Hybrid Mini Mental State Examination (HMMSE) adapted from Folstein's MMSE and Ganguli's Hindi Mental State Examination. The study sample had 204 subjects over the age of 60 years with a mean of 73 years and education level of 8 (4.5) years. Internal consistency for the CONCOG (Cronbach's alpha) was 0.74, inter-rater reliability (Kendall's tau-b) was 0.9, and the one-month test-retest reliability (Kendall's tau-b) was 0.7. Age and education level, but not gender, significantly influenced performance on both scales. Although the influence of age on the two scales was to a similar degree, the HMMSE was more affected by education than the CONCOG. Of 204 subjects, only 12 (5.7%) subjects obtained the maximum score on the CONCOG compared with 30 (14.1%) subjects on the HMMSE. The CONCOG took less than 10 minutes to complete in this sample. Age and education stratified norms are presented for the CONCOG. The CONCOG is a reliable cognitive screening measure. It has negligible ceiling effects, is less influenced by education compared with the HMMSE, and offers subscale scores for the major cognitive domains.

  20. Soleus H-reflex tests in causalgia-dystonia compared with dystonia and mimicked dystonic posture

    NARCIS (Netherlands)

    Koelman, J. H.; Hilgevoord, A. A.; Bour, L. J.; Speelman, J. D.; Ongerboer de Visser, B. W.

    1999-01-01

    Dystonia in the causalgia-dystonia syndrome is characterized by a fixed dystonic posture. To identify involvement of central pathophysiologic mechanisms, we analyzed soleus H-reflex tests in five patients with causalgia-dystonia. Soleus H-reflex test results in these patients differed from those in

  1. Test CMOS/SOS RAM for transient radiation upset comparative research and failure analysis

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Poljakov, I.V.

    1995-01-01

    The test Complementary Metal-Oxide-Semiconductor/Silicon-on-Sapphire Random Access Memory (CMOS/SOS RAM) with eight types of memory cells was designed and tested at high dose rates with a flash X-ray machine and laser simulator. The memory cell (MC) design with additional transistors and RC-chain was found to be upset free up to 2 x 10 12 rad(Si)/s. An inversion effect was discovered in which almost 100% logic upset was observed in poorly protected memory cell arrays at very high dose rates

  2. Performance-intensity functions of Mandarin word recognition tests in noise: test dialect and listener language effects.

    Science.gov (United States)

    Liu, Danzheng; Shi, Lu-Feng

    2013-06-01

    This study established the performance-intensity function for Beijing and Taiwan Mandarin bisyllabic word recognition tests in noise in native speakers of Wu Chinese. Effects of the test dialect and listeners' first language on psychometric variables (i.e., slope and 50%-correct threshold) were analyzed. Thirty-two normal-hearing Wu-speaking adults who used Mandarin since early childhood were compared to 16 native Mandarin-speaking adults. Both Beijing and Taiwan bisyllabic word recognition tests were presented at 8 signal-to-noise ratios (SNRs) in 4-dB steps (-12 dB to +16 dB). At each SNR, a half list (25 words) was presented in speech-spectrum noise to listeners' right ear. The order of the test, SNR, and half list was randomized across listeners. Listeners responded orally and in writing. Overall, the Wu-speaking listeners performed comparably to the Mandarin-speaking listeners on both tests. Compared to the Taiwan test, the Beijing test yielded a significantly lower threshold for both the Mandarin- and Wu-speaking listeners, as well as a significantly steeper slope for the Wu-speaking listeners. Both Mandarin tests can be used to evaluate Wu-speaking listeners. Of the 2, the Taiwan Mandarin test results in more comparable functions across listener groups. Differences in the performance-intensity function between listener groups and between tests indicate a first language and dialectal effect, respectively.

  3. Parametric Sensitivity Tests- European PEM Fuel Cell Stack Test Procedures

    DEFF Research Database (Denmark)

    Araya, Samuel Simon; Andreasen, Søren Juhl; Kær, Søren Knudsen

    2014-01-01

    performed based on test procedures proposed by a European project, Stack-Test. The sensitivity of a Nafion-based low temperature PEMFC stack’s performance to parametric changes was the main objective of the tests. Four crucial parameters for fuel cell operation were chosen; relative humidity, temperature......As fuel cells are increasingly commercialized for various applications, harmonized and industry-relevant test procedures are necessary to benchmark tests and to ensure comparability of stack performance results from different parties. This paper reports the results of parametric sensitivity tests......, pressure, and stoichiometry at varying current density. Furthermore, procedures for polarization curve recording were also tested both in ascending and descending current directions....

  4. Validation of differential gene expression algorithms: Application comparing fold-change estimation to hypothesis testing

    Directory of Open Access Journals (Sweden)

    Bickel David R

    2010-01-01

    performance. The posterior predictive assessment corroborates these findings. Conclusions Algorithms for detecting differential gene expression may be compared by estimating each algorithm's error in predicting expression ratios, whether such ratios are defined across microarray channels or between two independent groups. According to two distinct estimators of prediction error, algorithms using hierarchical models outperform the other algorithms of the study. The fact that fold-change shrinkage performed as well as conventional model selection criteria calls for investigating algorithms that combine the strengths of significance testing and fold-change estimation.

  5. Comparing endophenotypes in adult-onset primary torsion dystonia.

    LENUS (Irish Health Repository)

    Bradley, David

    2012-02-01

    Adult-onset primary torsion dystonia (AOPTD) has an autosomal dominant pattern of inheritance with markedly reduced penetrance; the genetic causes of most forms of AOPTD remain unknown. Endophenotypes, markers of sub-clinical gene carriage, may be of use detecting non-manifesting gene carriers in relatives of AOPTD patients. The aim of this study was to compare the utility of the spatial discrimination threshold (SDT) and temporal discrimination threshold (TDT) as potential endophenotypes in AOPTD. Data on other published candidate endophenotypes are also considered. Both SDT and TDT testing were performed in 24 AOPTD patients and 34 of their unaffected first degree relatives; results were compared with normal values from a control population. Of the 24 AOPTD patients 5 (21%) had abnormal SDTs and 20 (83%) had abnormal TDTs. Of the 34 first degree relatives 17 (50%) had abnormal SDTs and 14 (41%) had abnormal TDTs. Discordant results on SDT and TDT testing were found in 16 (67%) AOPTD patients and 21 (62%) first degree relatives. TDT testing has superior sensitivity compared to SDT testing in AOPTD patients; although false positive TDTs are recognised, the specificity of TDT testing in unaffected relatives is not determinable. The high level of discordance between the two tests probably relates methodological difficulties with SDT testing. The SDT is an unreliable AOPTD endophenotype; TDT testing fulfils criteria for a reliable endophenotype with a high sensitivity.

  6. Patterns of type 2 diabetes monitoring in rural towns: How does frequency of HbA1c and lipid testing compare with existing guidelines?

    Science.gov (United States)

    Paul, Christine L; Piterman, Leon; Shaw, Jonathan E; Kirby, Catherine; Barker, Daniel; Robinson, Jennifer; Forshaw, Kristy L; Sikaris, Kenneth A; Bisquera, Alessandra; Sanson-Fisher, Robert W

    2016-12-01

    To indicate levels of monitoring of type 2 diabetes in rural and regional Australia by examining patterns of glycated haemoglobin (HbA1c) and blood lipid testing. Retrospective analysis of pathology services data from twenty regional and rural towns in eastern Australia over 24 months. Of 13 105 individuals who had either a single HbA1c result ≥7.0% (53 mmol mol -1 ); or two or more HbA1c tests within the study period. Frequency of testing of HbA1c and blood lipids (cholesterol, low-density lipoprotein (LDL) cholesterol, high-density lipoprotein (HDL) cholesterol and triglycerides) were compared with guideline recommendations. About 58.3% of patients did not have the recommended 6-monthly HbA1c tests and 30.6% did not have annual lipid testing. For those who did not receive tests at the recommended interval, the mean between-test interval was 10.5 months (95% CI = 7.5-13.5) rather than 6 months for HbA1c testing; and 15.7 (95% CI = 13.3-18.1) months rather than annually for blood lipids. For those with at least one out-of-range test result, 77% of patients failed to receive a follow-up HbA1c test and 86.5% failed to receive a follow-up blood lipid test within the recommended 3 months. Patients less than 50 years of age, living in a more remote area and with poor diabetes control were less likely to have testing at the recommended intervals (P < 0.0001). Although poor diabetes testing is not limited to rural areas, more intensive diabetes monitoring is likely to be needed for patients living in non-metropolitan areas, particularly for some subgroups. © 2016 National Rural Health Alliance Inc.

  7. Solid-phase enzyme immunoassay or radioimmunoassay for the detection of immune complexes based on their recognition by conglutinin: conglutinin-binding test. A comparative study with /sup 125/I-labelled Clq binding and Raji-cell RIA tests

    Energy Technology Data Exchange (ETDEWEB)

    Casali, P; Bossus, A; Carpentier, N A; Lambert, P H [Hopital Cantonal Geneve (Switzerland)

    1977-01-01

    Bovine conglutinin was used in a solid-phase assay for the detection of immune complexes. In a first step, the tested serum sample was incubated in polypropylene tubes coated with conglutinin to allow C3-coated immune complexes to bind to solid-phase conglutinin. In a second step, the conglutinin-bound complexes were detected using an enzyme-conjugated or radiolabelled anti-immunoglobulin antibody. The conglutinin-binding (KgB) test did not suffer from the interference of DNA, heparin or endotoxins. Its limit of sensitivity for aggregated IgG was 3 ..mu..g/ml undiluted human serum. Immune complexes prepared in vitro using tetanus toxoid, or DNA, and corresponding antibodies in human sera could be detected at various antigen/antibody ratios and at antibody concentrations lower than 8 ..mu..g/ml. The KgB test allowed for the detection of immune complexes in sera from patients with systemic lupus erythematosus, rheumatoid arthritis, idiopathic vasculitis, leprosy and leukemia. These sera were also tested using the /sup 125/I-labelled Clq-binding activity (BA) test and the KgB test simultaneously, and a significant rank order correlation was observed. In patients with leukemia, a significant correlation was observed using three tests, KgB, /sup 125/I-labelled Clq BA and Raji-cell radioimmunoassay (RIA). Therefore, the KgB test appears as a simple and reproducible method, utilizing a very stable reagent, with a sensitivity and specificity comparable to the other tests studied and allowing for clinical application.

  8. Guidelines for Remote Handling Maintenance of ITER Neutral Beam Components

    International Nuclear Information System (INIS)

    Cordier, J.-J.; Hemsworth, R.; Bayetti, P.

    2006-01-01

    Remote handling maintenance of ITER components is one of the main challenges of the ITER project. This type of maintenance shall be operational for the nuclear phase of exploitation of ITER, and be considered at a very early stage since it significantly impacts on the components design, interfaces management and integration business. A large part of the R/H equipment will be procured by the EU partner, in particular the whole Neutral Beam Remote Handling (RH) equipment package. A great deal of work has already been done in this field during the EDA phase of ITER project, but improvements and alternative option that are now proposed by ITER lead to added RH and maintenance engineering studies. The Neutral Beam Heating -and- Current Drive system 1 is being revisited by the ITER project. The vertical maintenance scheme that is presently considered by ITER, may significantly impact on the reference design of the Neutral Beam (NB) system and associated components and lead to new design of the NB box itself. In addition, revision of both NB cell radiation level zoning and remote handling classification of the beam line injector will also significantly impact on components design and maintenance. Based on the experience gained on the vertical maintenance scheme, developed in detail for the ITER Neutral Beam Test Facility 2 to be built in Europe in a near future, guidelines for the revision of the design and preliminary feasibility study of the remote handling vertical maintenance scheme of beam line components are described in the paper. A maintenance option for the SINGAP3 accelerator is also presented. (author)

  9. Comparing different kinds of words and word-word relations to test an habituation model of priming.

    Science.gov (United States)

    Rieth, Cory A; Huber, David E

    2017-06-01

    Huber and O'Reilly (2003) proposed that neural habituation exists to solve a temporal parsing problem, minimizing blending between one word and the next when words are visually presented in rapid succession. They developed a neural dynamics habituation model, explaining the finding that short duration primes produce positive priming whereas long duration primes produce negative repetition priming. The model contains three layers of processing, including a visual input layer, an orthographic layer, and a lexical-semantic layer. The predicted effect of prime duration depends both on this assumed representational hierarchy and the assumption that synaptic depression underlies habituation. The current study tested these assumptions by comparing different kinds of words (e.g., words versus non-words) and different kinds of word-word relations (e.g., associative versus repetition). For each experiment, the predictions of the original model were compared to an alternative model with different representational assumptions. Experiment 1 confirmed the prediction that non-words and inverted words require longer prime durations to eliminate positive repetition priming (i.e., a slower transition from positive to negative priming). Experiment 2 confirmed the prediction that associative priming increases and then decreases with increasing prime duration, but remains positive even with long duration primes. Experiment 3 replicated the effects of repetition and associative priming using a within-subjects design and combined these effects by examining target words that were expected to repeat (e.g., viewing the target word 'BACK' after the prime phrase 'back to'). These results support the originally assumed representational hierarchy and more generally the role of habituation in temporal parsing and priming. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Comparative diagnostic accuracy in virtual dermatopathology

    DEFF Research Database (Denmark)

    Mooney, E.; Hood, A.F.; Lampros, J.

    2011-01-01

    studies comparing the diagnostic accuracy and acceptability of virtual slides compared to traditional glass slides. Methods: Ten Nordic dermatopathologists and pathologists were given a randomized combination of 20 virtual and glass slides and asked to identify the diagnoses. They were then asked to give...... their impressions about the virtual images. Descriptive data analysis and comparison of groups using Fisher's exact test were performed. Objective: To compare the diagnostic ability of dermatopathologists and pathologists in two image formats: the traditional (glass) microscopic slides, and whole mount digitized...... of virtual or glass slides did not affect the percentage of questions answered correctly. Seven of nine participants completing the questionnaire, felt virtual microscopy is useful for both learning and testing. Conclusion: There was no significant difference in the participants' diagnostic ability using...

  11. A retrospective evaluation of proficiency testing, and rapid HIV test ...

    African Journals Online (AJOL)

    Background: Proficiency testing (PT) has been implemented as a form of External Quality Assurance (EQA) by the National HIV Reference Laboratory in Kenya since 2007 in order to monitor and improve on the quality of HIV testing and counselling HTC services. Objective: To compare concordance between National HIV ...

  12. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  13. Graded Cycling Test Combined With the Talk Test Is Responsive in Cardiac Rehabilitation

    DEFF Research Database (Denmark)

    Nielsen, Susanne Grøn; Vinther, Anders

    2016-01-01

    PURPOSE: To evaluate clinical assessment outcome of cardiac rehabilitation, a simple and reliable submaximal exercise test, not based on heart rate, is warranted. The Talk Test (TT) has been found to correlate well with the ventilatory threshold, and excellent reliability was observed for TT...... combined with the Graded Cycling Test (GCT-TT) in cardiac patients. The purpose was to investigate responsiveness of GCT-TT in cardiac rehabilitation patients. METHODS: Patients (n = 93) referred to 8 weeks of cardiac rehabilitation were included. Pre- and posttests were performed using GCT-TT. Mean test...... changes in watts (W) were compared with the standard error of measurement (SEM95) for groups and the smallest real difference (SRD) for individuals. Minimal clinically important difference was assessed by comparing patient perceived changes in physical fitness with the test changes. RESULTS...

  14. Assessment and comparative analysis of a rapid diagnostic test (Tubex® for the diagnosis of typhoid fever among hospitalized children in rural Tanzania

    Directory of Open Access Journals (Sweden)

    Shoo Aikande

    2011-05-01

    Full Text Available Abstract Background Typhoid fever remains a significant health problem in many developing countries. A rapid test with a performance comparable to that of blood culture would be highly useful. A rapid diagnostic test for typhoid fever, Tubex®, is commercially available that uses particle separation to detect immunoglobulin M directed towards Salmonella Typhi O9 lipopolysaccharide in sera. Methods We assessed the sensitivity and specificity of the Tubex test among Tanzanian children hospitalized with febrile illness using blood culture as gold standard. Evaluation was done considering blood culture confirmed S. Typhi with non-typhi salmonella (NTS and non - salmonella isolates as controls as well as with non-salmonella isolates only. Results Of 139 samples tested with Tubex, 33 were positive for S. Typhi in blood culture, 49 were culture-confirmed NTS infections, and 57 were other non-salmonella infections. Thirteen hemolyzed samples were excluded. Using all non - S. Typhi isolates as controls, we showed a sensitivity of 79% and a specificity of 89%. When the analysis was repeated excluding NTS from the pool of controls we showed a sensitivity of 79% and a specificity of 97%. There was no significant difference in the test performance using the two different control groups (p > 0.05. Conclusion This first evaluation of the Tubex test in an African setting showed a similar performance to those seen in some Asian settings. Comparison with the earlier results of a Widal test using the same samples showed no significant difference (p > 0.05 for any of the performance indicators, irrespective of the applied control group.

  15. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    Hwang, W.S.; Alamgir, M.; Sutherland, W.A.

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  16. [Objective evaluation of arterial intermittent claudication by the walking tolerance test. Comparative study of physiological walking and walking on a conveyor belt (author's transl)].

    Science.gov (United States)

    Bouchet, J Y; Franco, A; Morzol, B; Beani, J C

    1980-01-01

    Two methods are used to evaluate the walking distance: physiological walking along a standard path (0% - 6 mk/h) and walking on a tread mill (10% - 3 km/h). In both tests, four data are checked: -- initial trouble distance, -- cramp or walking-distance, -- localisation of pain, -- recovery time. These tests are dependable for the diagnosis of arterial claudication, reproducible and well tolerated. Their results have been compared: there is no correlation between the initial trouble distance and the cramp distance. However there is a correlation between the cramp distance by physiological walking and on treadmill. Recovery time, if long, is a criteria of gravity. Interests of both methods are discussed.

  17. Experimental tests on winter cereal: Sod seeding compared to minimum tillage and traditional plowing

    Directory of Open Access Journals (Sweden)

    Antoniotto Guidobono Cavalchini

    2013-09-01

    Full Text Available Compared to traditional plowing and minimum tillage, the sod seeding technique has been tested in order to evaluate the differences in energy consumption, labor and machinery requirement and CO2 emission reduction. The experiments were conducted on winter cereal seeding in a Po valley farm in October 2011. The tests were carried out as follows: wheat variety seeding, over corn and alfalfa crops, in large plots with three repetitions for each thesis. They included: sod seeding anticipated by round up weeding in the case of the plots over alfalfa; traditional plowing at 35 cm followed by rotary tillage and combined seeding (seeder plus rotary tiller; minimum tillage based on ripping at the same depth (35 cm and combined seeder ( seeder plus rotary tiller. The following farm operations - fertilizer, and other agrochemical distributionshave been the same in all the considered theses. The results, statistically significant (P<0.001 in terms of yields, highlighted slight differences: the best data in the case of the traditional plowing both in the case of wheat crop over corn and alfalfa (84.43 and 6.75 t/ha; slightly lower yields for the sod seeding (6.23 and 79.9 t/ha for corn and alfalfa respectively; lower in the case of minimum tillage (5.87; 79.77 t/ha in the two situations. Huge differences in energy and oil consumption have been recorded: in the case of succession to corn 61.47; 35.31; 4.27 kg oil/ha respectively for, traditional plowing, minimum tillage and sod seeding; in the case of alfalfa 61.2; 50.96; 5.14 kg oil/ha respectively for traditional plowing, minimum tillage and sod seeding. The innovative technique, highlighted huge energy saving with an oil consumption equal to 92% and 89% (P<0.001 of what happens in traditional plowing and minimum tillage. Large differences concern labor and machine productivity. These parameters together with oil consumption and machine size [power (kW and weight (t] lead to even greater differences in

  18. Comparative strength analysis and thermal fatigue testing of Be/CuCrZr and Be/GlidCop joints produced by fast brazing

    International Nuclear Information System (INIS)

    Gervash, A.; Mazul, I.; Yablokov, N.; Barabash, V.; Ganenko, A.

    2000-01-01

    Proposing beryllium as plasma facing armour this paper presents the recent results obtained in Russia in the frame of such activities. Last year testing of actively cooled mock-ups produced by fast brazing of Be onto Cu-alloy heat sink allows to consider mentioned Russian method as promising for both PH-copper like CuCrZr and DS-copper like GlidCop. Summarizing recent experimental results with their previous data authors attempt to comparatively investigate a behaviour of Be/CuCrZr and Be/GlidCop joints in ITER relevant conditions. Mechanical properties, brazing zone microstructure and thermal response were taken for comparison. The shear strength for both types of joints was found as 150-200 MPa and did not depend on testing temperature. The brazing zone morphology and microhardness are presented, the thermal fatigue behaviour of investigated joints is described. All main results as well as the nearest future plans are discussed. (orig.)

  19. Comparative study of the tests of fat absorption using triolein or oleic acid labelled with 131I and 14C

    International Nuclear Information System (INIS)

    Grenier, J.F.; Dauchel, J.; Eloy, M.R.; Mendel, C.; Privat, J.P.

    1976-01-01

    Studies of the absorption of radioiodinated fats introduced into the lumen of isolated intestinal loops of dogs have shown that these compounds are promptly and to a large extent dehalogenated, not only in the small bowel, but also in the colon. Further comparative experimental studies on dogs and patients, using 14 C-labelled fats, have demonstrated that the absorption of the mineral 131 I and of the fats is not simultaneous. Therefore, the use of triolein labelled with 131 I to measure fat absorption should be abandoned. However, it is concluded that tests of intestinal absorption using 14 C-labelled triolein are of great interest. (author)

  20. Ultrasonic testing X gammagraphy

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The experience of 10 years for substituting gammagraphy tests by ultrasonic tests is related. A comparative evaluation of data obtained from both techniques applied to welded butt joints is presented. (author)

  1. Analysing Test-Takers’ Views on a Computer-Based Speaking Test

    Directory of Open Access Journals (Sweden)

    Marian Amengual-Pizarro

    2017-11-01

    Full Text Available This study examines test-takers’ views on a computer-delivered speaking test in order to investigate the aspects they consider most relevant in technology-based oral assessment, and to explore the main advantages and disadvantages computer-based tests may offer as compared to face-to-face speaking tests. A small-scale open questionnaire was administered to 80 test-takers who took the APTIS speaking test at the Universidad de Alcalá in April 2016. Results reveal that examinees believe computer-based tests provide a valid measure of oral competence in English and are considered to be an adequate method for the assessment of speaking. Interestingly, the data suggest that personal characteristics of test-takers seem to play a key role in deciding upon the most suitable and reliable delivery mode.

  2. Comparing sensitivity of ecotoxicological effect endpoints between laboratory and field

    DEFF Research Database (Denmark)

    Selck, H.; Riemann, B.; Christoffersen, K.

    2002-01-01

    multispecies field tests using tributyltin (TBT) and linear alkylbenzene sulfonates (LAS) were compared with published laboratory single-species test results and measured in situ concentrations. Extrapolation methods were evaluated by comparing predicted no-effect concentrations (PNECs), calculated by AF...

  3. Comparative pharmacognosy of Pashanbhed

    Directory of Open Access Journals (Sweden)

    Poonam Verma

    2014-01-01

    Full Text Available Background: Pashanbhed is a commercially available diuretic and lithotropic drug, used to treat renal problems. It is a controversial name as it is assigned to various plants such as Bergenia ligulata, Kalanchoe pinnata, Coleus aromaticus and Rotula aquatica. Objective: To perform the comparative preliminary phytochemical screening, diuretic activity, and thin layer chromatography (TLC finger printing profile of three plants (B. ligulata, C. aromaticus, and K. pinnata, most commonly used as Pashanbhed. Materials and Methods: Diuretic potential of methanolic extract (ME of three plants were evaluated at two dose levels (500 and 1,000 mg/kg p.o., using normal Wistar rats (Lipschitz method. Furosemide (20 mg/kg p.o. was used as a standard drug. The effect on urine output and electrolyte changes were measured for 24 h and compared. All MEs were screened preliminarily for their constituents and their TLC finger printing profiles were prepared. One-way analysis of variance (ANOVA followed by Bonferroni′s multiple comparison test. P < 0.05 was considered statistically significant. Results: The MEs of all three plants have shown diuresis in normal rats. However, in intercomparison of the ME C. aromaticus (1,000 mg/kg p.o. produced more significant diuresis (P < 0.05 and electrolyte excretion compared to other test groups, the effect was at par with furosemide. The ME of these plants showed presence of alkaloids, glycosides, steroids, terpenoids, saponins, flavonoids, etc. Conclusion: The ME of C. aromaticus (1,000 mg/kg p.o. has showed highest diuretic action (4.2 among the tested extracts. This suggests the use of C. aromaticus leaves as "Pashanbhed"; the most effective diuretic drug.

  4. Comparative pharmacognosy of Pashanbhed

    Science.gov (United States)

    Verma, Poonam; Gauttam, Vinod; Kalia, Ajudhia N.

    2014-01-01

    Background: Pashanbhed is a commercially available diuretic and lithotropic drug, used to treat renal problems. It is a controversial name as it is assigned to various plants such as Bergenia ligulata, Kalanchoe pinnata, Coleus aromaticus and Rotula aquatica. Objective: To perform the comparative preliminary phytochemical screening, diuretic activity, and thin layer chromatography (TLC) finger printing profile of three plants (B. ligulata, C. aromaticus, and K. pinnata), most commonly used as Pashanbhed. Materials and Methods: Diuretic potential of methanolic extract (ME) of three plants were evaluated at two dose levels (500 and 1,000 mg/kg p.o.), using normal Wistar rats (Lipschitz method). Furosemide (20 mg/kg p.o.) was used as a standard drug. The effect on urine output and electrolyte changes were measured for 24 h and compared. All MEs were screened preliminarily for their constituents and their TLC finger printing profiles were prepared. One-way analysis of variance (ANOVA) followed by Bonferroni's multiple comparison test. P < 0.05 was considered statistically significant. Results: The MEs of all three plants have shown diuresis in normal rats. However, in intercomparison of the ME C. aromaticus (1,000 mg/kg p.o.) produced more significant diuresis (P < 0.05) and electrolyte excretion compared to other test groups, the effect was at par with furosemide. The ME of these plants showed presence of alkaloids, glycosides, steroids, terpenoids, saponins, flavonoids, etc. Conclusion: The ME of C. aromaticus (1,000 mg/kg p.o.) has showed highest diuretic action (4.2) among the tested extracts. This suggests the use of C. aromaticus leaves as “Pashanbhed”; the most effective diuretic drug. PMID:24948861

  5. Comparative parameters of solar cells for power generation: test stand implementation using DSP

    International Nuclear Information System (INIS)

    Álvarez López, Ramón Antonio; García Angarita, Maritza Andrea

    2014-01-01

    The technologies used in solar modules are distinguished mainly by th eenergy conversion efficiency. Consequently, the module selection is critic to the long term performance of photovoltaic generating facility. Therefore, the selection must be supported by experimental results obtained under a specific operation condition. The article implements an experimentally test for obtain the characteristic parameters of a solar module, we analyze the energy conversion efficiency and other correlated parameters that directly affect the performance of a photovoltaic generator. The results show that the use of a rapid prototyping system using open hardware, such as TMS320F28335 development kit makes it easy to build a test photovoltaic generation systems. Latter justified by the low cost of such devices and ease of programming. (author)

  6. A comparative evaluation of the process of developing and implementing an emergency department HIV testing program

    Directory of Open Access Journals (Sweden)

    Weiser Sheri

    2011-03-01

    Full Text Available Abstract Background The 2006 Centers for Disease Control and Prevention (CDC HIV testing guidelines recommend screening for HIV infection in all healthcare settings, including the emergency department (ED. In urban areas with a high background prevalence of HIV, the ED has become an increasingly important site for identifying HIV infection. However, this public health policy has been operationalized using different models. We sought to describe the development and implementation of HIV testing programs in three EDs, assess factors shaping the adoption and evolution of specific program elements, and identify barriers and facilitators to testing. Methods We performed a qualitative evaluation using in-depth interviews with fifteen 'key informants' involved in the development and implementation of HIV testing in three urban EDs serving sizable racial/ethnic minority and socioeconomically disadvantaged populations. Testing program HIV prevalence ranged from 0.4% to 3.0%. Results Three testing models were identified, reflecting differences in the use of existing ED staff to offer and perform the test and disclose results. Factors influencing the adoption of a particular model included: whether program developers were ED providers, HIV providers, or both; whether programs took a targeted or non-targeted approach to patient selection; and the extent to which linkage to care was viewed as the responsibility of the ED. A common barrier was discomfort among ED providers about disclosing a positive HIV test result. Common facilitators were a commitment to underserved populations, the perception that testing was an opportunity to re-engage previously HIV-infected patients in care, and the support and resources offered by the medical setting for HIV-infected patients. Conclusions ED HIV testing is occurring under a range of models that emerge from local realities and are tailored to institutional strengths to optimize implementation and overcome provider

  7. Modelling the Impact and Cost-Effectiveness of Biomarker Tests as Compared with Pathogen-Specific Diagnostics in the Management of Undifferentiated Fever in Remote Tropical Settings.

    Science.gov (United States)

    Lubell, Yoel; Althaus, Thomas; Blacksell, Stuart D; Paris, Daniel H; Mayxay, Mayfong; Pan-Ngum, Wirichada; White, Lisa J; Day, Nicholas P J; Newton, Paul N

    2016-01-01

    Malaria accounts for a small fraction of febrile cases in increasingly large areas of the malaria endemic world. Point-of-care tests to improve the management of non-malarial fevers appropriate for primary care are few, consisting of either diagnostic tests for specific pathogens or testing for biomarkers of host response that indicate whether antibiotics might be required. The impact and cost-effectiveness of these approaches are relatively unexplored and methods to do so are not well-developed. We model the ability of dengue and scrub typhus rapid tests to inform antibiotic treatment, as compared with testing for elevated C-Reactive Protein (CRP), a biomarker of host-inflammation. Using data on causes of fever in rural Laos, we estimate the proportion of outpatients that would be correctly classified as requiring an antibiotic and the likely cost-effectiveness of the approaches. Use of either pathogen-specific test slightly increased the proportion of patients correctly classified as requiring antibiotics. CRP testing was consistently superior to the pathogen-specific tests, despite heterogeneity in causes of fever. All testing strategies are likely to result in higher average costs, but only the scrub typhus and CRP tests are likely to be cost-effective when considering direct health benefits, with median cost per disability adjusted life year averted of approximately $48 USD and $94 USD, respectively. Testing for viral infections is unlikely to be cost-effective when considering only direct health benefits to patients. Testing for prevalent bacterial pathogens can be cost-effective, having the benefit of informing not only whether treatment is required, but also as to the most appropriate antibiotic; this advantage, however, varies widely in response to heterogeneity in causes of fever. Testing for biomarkers of host inflammation is likely to be consistently cost-effective despite high heterogeneity, and can also offer substantial reductions in over-use of

  8. msBayes: Pipeline for testing comparative phylogeographic histories using hierarchical approximate Bayesian computation

    Directory of Open Access Journals (Sweden)

    Takebayashi Naoki

    2007-07-01

    Full Text Available Abstract Background Although testing for simultaneous divergence (vicariance across different population-pairs that span the same barrier to gene flow is of central importance to evolutionary biology, researchers often equate the gene tree and population/species tree thereby ignoring stochastic coalescent variance in their conclusions of temporal incongruence. In contrast to other available phylogeographic software packages, msBayes is the only one that analyses data from multiple species/population pairs under a hierarchical model. Results msBayes employs approximate Bayesian computation (ABC under a hierarchical coalescent model to test for simultaneous divergence (TSD in multiple co-distributed population-pairs. Simultaneous isolation is tested by estimating three hyper-parameters that characterize the degree of variability in divergence times across co-distributed population pairs while allowing for variation in various within population-pair demographic parameters (sub-parameters that can affect the coalescent. msBayes is a software package consisting of several C and R programs that are run with a Perl "front-end". Conclusion The method reasonably distinguishes simultaneous isolation from temporal incongruence in the divergence of co-distributed population pairs, even with sparse sampling of individuals. Because the estimate step is decoupled from the simulation step, one can rapidly evaluate different ABC acceptance/rejection conditions and the choice of summary statistics. Given the complex and idiosyncratic nature of testing multi-species biogeographic hypotheses, we envision msBayes as a powerful and flexible tool for tackling a wide array of difficult research questions that use population genetic data from multiple co-distributed species. The msBayes pipeline is available for download at http://msbayes.sourceforge.net/ under an open source license (GNU Public License. The msBayes pipeline is comprised of several C and R programs that

  9. A comparison of test statistics for the recovery of rapid growth-based enumeration tests

    NARCIS (Netherlands)

    van den Heuvel, Edwin R.; IJzerman-Boon, Pieta C.

    This paper considers five test statistics for comparing the recovery of a rapid growth-based enumeration test with respect to the compendial microbiological method using a specific nonserial dilution experiment. The finite sample distributions of these test statistics are unknown, because they are

  10. The 100-meter timed test: Normative data in healthy males and comparative pilot outcome data for use in Duchenne muscular dystrophy clinical trials.

    Science.gov (United States)

    Alfano, Lindsay N; Miller, Natalie F; Berry, Katherine M; Yin, Han; Rolf, Kimberly E; Flanigan, Kevin M; Mendell, Jerry R; Lowes, Linda P

    2017-05-01

    Timed walking tests are often used to measure function in boys with Duchenne muscular dystrophy (DMD). Our objective was to evaluate the 100 meter timed test (100m), a fixed distance test of maximal performance, for use in DMD. To this end, we sought to establish normative 100m performance in healthy controls, compare DMD performance to controls, and evaluate the reliability of 100m. Seventy-two boys with DMD (18 steroid-naïve, 54 on steroids) and 599 controls (4-14 years) completed the 100m as speedily as possible on a 25-meter track. Repeat testing was completed between 1 and 42 days later and again at 1 year in a subgroup of 96 control boys. Additionally 35 DMD boys were followed longitudinally (5-19 months). Descriptive statistics are presented by age and cohort. There was a significant difference in performance between groups (p  0.90, p < 0.001). Normative data can be used to determine percent-predicted 100m times to quantify the severity of running impairment in children with a motor deficit. Performance of 100m follows the natural history established by other outcome measures in DMD. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Patients' attitudes towards animal testing

    DEFF Research Database (Denmark)

    Masterton, Malin; Renberg, Tobias; Kälvemark Sporrong, Sofia

    2014-01-01

    stakeholders. This study compared the attitudes of patients and researchers on animal testing. Focus-group interviews were held with patients suffering from chronic inflammatory diseases, resulting in a questionnaire that was distributed January–May 2011. The questionnaire was posted to patient members...... of support is comparable to those held by the general public found in national surveys. A clear majority of researchers were positive towards animal testing, and large statistical differences between patients and researchers were found regarding their attitudes towards testing animals commonly held as pets...... (Pattitude towards animal testing is not shared to an equal degree with patients, who are the intended end-users and beneficiaries of medical...

  12. Justification and crush tests compared with fall tests in relation to changes in existing regulations

    International Nuclear Information System (INIS)

    Chevalier, G.; Gilles, P.; Pouard, M.

    1983-05-01

    The I.A.E.A. regulations applied to validate type B packages in an accidental situation represent a perfectly logical simulation of what could happen during transport, for most packages: - collision at 47.8 km/h with a very rigid obstacle, - local damage of 9.8 times the mass in joules (150 mm diameter punch test). These accident levels are justified for packages weighing 1000 kg to 50000 kg (between the mass of a car and that of a very large loaded transport vehicles). Under 500 kg, the aggression level required by the regulations seems insufficient in comparison with possible accidents, and experience shows that the packages in service in France display a resistance capacity closer to probable accidents than the minimum requirements of the regulations. Above 50 tons and around 100 tons, it seems that the situation is reversed, the requirements of the regulations appear to be much more severe than the probable accidents, and when a large package is located, it would seem to be more important to be concerned with the damage that this package would cause to the civil works than the damage that it would itself suffer [fr

  13. Post-mortem diagnosis of chronic Chagas's disease comparative evaluation of three serological tests on pericardial fluid.

    Science.gov (United States)

    Lopes, E R; Chapadeiro, E; Batista, S M; Cunha, J G; Rocha, A; Miziara, L; Ribeiro, J U; Patto, R J

    1978-01-01

    In an attempt to improve the post-mortem diagnosis of Chagas's disease the authors performed haemagglutination tests (HAT), fluorescent Trypanosoma cruzi antibody tests (FAT), and complement fixation tests (CFT) on the pericardial fluid obtained at autopsy of 50 individuals with Chagas's heart disease, and 93 patients in whom this disease was not thought to be present. The results demonstrate that all three tests are efficient for the post-mortem diagnosis of Chagas's disease but suggest that their combined use would detect more cases than would one isolated reaction only.

  14. Cervical flexion-rotation test and physiological range of motion - A comparative study of patients with myogenic temporomandibular disorder versus healthy subjects.

    Science.gov (United States)

    Greenbaum, Tzvika; Dvir, Zeevi; Reiter, Shoshana; Winocur, Ephraim

    2017-02-01

    Temporomandibular Disorders (TMD) refer to several common clinical disorders which involve the masticatory muscles, the temporomandibular joint (TMJ) and the adjacent structures. Although neck signs and symptoms are found with higher prevalence in TMD patients compared to the overall population, whether limitation of cervical mobility is an additional positive finding in this cohort is still an open question. To compare the physiological cervical range of motion (CROM) and the extent of rotation during cervical flexion (flexion-rotation test, FRT) in people with TMD (muscular origin) and healthy control subjects. The range of motion of the neck and FRT was measured in 20 women with myogenic TMD and 20 age matched healthy controls. Women with myogenic TMD had significantly lower FRT scores compared to their matched healthy women. No difference was found between groups in CROM in any of the planes of movement. The FRT was positive (less than 32°) in 90% of the TMD participants versus 5% in the healthy control but the findings were not correlated with TMD severity. The results point out a potential involvement of the upper cervical joints (c1-c2) in women with myogenic TMD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Earthquake likelihood model testing

    Science.gov (United States)

    Schorlemmer, D.; Gerstenberger, M.C.; Wiemer, S.; Jackson, D.D.; Rhoades, D.A.

    2007-01-01

    wide range of possible testing procedures exist. Jolliffe and Stephenson (2003) present different forecast verifications from atmospheric science, among them likelihood testing of probability forecasts and testing the occurrence of binary events. Testing binary events requires that for each forecasted event, the spatial, temporal and magnitude limits be given. Although major earthquakes can be considered binary events, the models within the RELM project express their forecasts on a spatial grid and in 0.1 magnitude units; thus the results are a distribution of rates over space and magnitude. These forecasts can be tested with likelihood tests.In general, likelihood tests assume a valid null hypothesis against which a given hypothesis is tested. The outcome is either a rejection of the null hypothesis in favor of the test hypothesis or a nonrejection, meaning the test hypothesis cannot outperform the null hypothesis at a given significance level. Within RELM, there is no accepted null hypothesis and thus the likelihood test needs to be expanded to allow comparable testing of equipollent hypotheses.To test models against one another, we require that forecasts are expressed in a standard format: the average rate of earthquake occurrence within pre-specified limits of hypocentral latitude, longitude, depth, magnitude, time period, and focal mechanisms. Focal mechanisms should either be described as the inclination of P-axis, declination of P-axis, and inclination of the T-axis, or as strike, dip, and rake angles. Schorlemmer and Gerstenberger (2007, this issue) designed classes of these parameters such that similar models will be tested against each other. These classes make the forecasts comparable between models. Additionally, we are limited to testing only what is precisely defined and consistently reported in earthquake catalogs. Therefore it is currently not possible to test such information as fault rupture length or area, asperity location, etc. Also, to account

  16. Implementing and expanding HIV testing in immigrant populations in Europe: Comparing guideline's recommendations and expert's opinions.

    Science.gov (United States)

    Álvarez-Del Arco, Débora; Monge, Susana; Rivero-Montesdeoca, Yaiza; Burns, Fiona; Noori, Teymur; Del Amo, Julia

    2017-01-01

    Immigrant populations, especially those from endemic countries, living in the European Union (EU) suffer a disproportionate burden of HIV, delayed diagnosis and poorer access to antiretroviral treatment. While International Organisations are developing recommendations aimed at increasing the uptake of HIV testing, the feasibility and real outcomes of these measures remain unexplored. The aim of this review was, firstly to identify the recommendations of the main International Organisations (IO) on HIV testing in immigrants. Secondly, to describe the challenges for implementing and expanding HIV testing and counselling interventions targeting immigrants by interviewing key informants. The importance of HIV testing in immigrants is discussed, along with the appropriateness of universal HIV testing approaches vs most at risk targeted approaches. Also addressed is, pre- and post-HIV test counselling characteristics and community initiatives suitable to reach this population and, finally the legal issues regarding access to treatment for illegal immigrants. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  17. Comparative test results of various beam loss monitors in preparation for LHC

    OpenAIRE

    Bosser, Jacques; Ferioli, G

    1999-01-01

    Beam loss detectors will play an important role in the protection of the superconducting LHC magnets. Different types of detectors have been tested in the SPS ring and secondary beam lines with a view to their possible use for this application. This paper describes the measurements made with: microcalorimeters at cryogenic temperatures, PIN diodes, ionisation chambers, scintillators, and ACEMs. Measurements made using proton beams showing their relative sensitivities, linearities in counting ...

  18. Transfer of analytical procedures: a panel of strategies selected for risk management, with emphasis on an integrated equivalence-based comparative testing approach.

    Science.gov (United States)

    Agut, C; Caron, A; Giordano, C; Hoffman, D; Ségalini, A

    2011-09-10

    In 2001, a multidisciplinary team made of analytical scientists and statisticians at Sanofi-aventis has published a methodology which has governed, from that time, the transfers from R&D sites to Manufacturing sites of the release monographs. This article provides an overview of the recent adaptations brought to this original methodology taking advantage of our experience and the new regulatory framework, and, in particular, the risk management perspective introduced by ICH Q9. Although some alternate strategies have been introduced in our practices, the comparative testing one, based equivalence testing as statistical approach, remains the standard for assays lying on very critical quality attributes. This is conducted with the concern to control the most important consumer's risk involved at two levels in analytical decisions in the frame of transfer studies: risk, for the receiving laboratory, to take poor release decisions with the analytical method and risk, for the sending laboratory, to accredit such a receiving laboratory on account of its insufficient performances with the method. Among the enhancements to the comparative studies, the manuscript presents the process settled within our company for a better integration of the transfer study into the method life-cycle, just as proposals of generic acceptance criteria and designs for assay and related substances methods. While maintaining rigor and selectivity of the original approach, these improvements tend towards an increased efficiency in the transfer operations. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Can trained lay providers perform HIV testing services? A review of national HIV testing policies.

    Science.gov (United States)

    Flynn, David E; Johnson, Cheryl; Sands, Anita; Wong, Vincent; Figueroa, Carmen; Baggaley, Rachel

    2017-01-04

    Only an estimated 54% of people living with HIV are aware of their status. Despite progress scaling up HIV testing services (HTS), a testing gap remains. Delivery of HTS by lay providers may help close this testing gap, while also increasing uptake and acceptability of HIV testing among key populations and other priority groups. 50 National HIV testing policies were collated from WHO country intelligence databases, contacts and testing program websites. Data regarding lay provider use for HTS was extracted and collated. Our search had no geographical or language restrictions. This data was then compared with reported data from the Global AIDS Response Progress Reporting (GARPR) from July 2015. Forty-two percent of countries permit lay providers to perform HIV testing and 56% permit lay providers to administer pre-and post-test counseling. Comparative analysis with GARPR found that less than half (46%) of reported data from countries were consistent with their corresponding national HIV testing policy. Given the low uptake of lay provider use globally and their proven use in increasing HIV testing, countries should consider revising policies to support lay provider testing using rapid diagnostic tests.

  20. Goodness of Fit Test and Test of Independence by Entropy

    Directory of Open Access Journals (Sweden)

    M. Sharifdoost

    2009-06-01

    Full Text Available To test whether a set of data has a specific distribution or not, we can use the goodness of fit test. This test can be done by one of Pearson X 2 -statistic or the likelihood ratio statistic G 2 , which are asymptotically equal, and also by using the Kolmogorov-Smirnov statistic in continuous distributions. In this paper, we introduce a new test statistic for goodness of fit test which is based on entropy distance, and which can be applied for large sample sizes. We compare this new statistic with the classical test statistics X 2 , G 2 , and Tn by some simulation studies. We conclude that the new statistic is more sensitive than the usual statistics to the rejection of distributions which are almost closed to the desired distribution. Also for testing independence, a new test statistic based on mutual information is introduced

  1. A Global Comparative Evaluation of Commercial Immunochromatographic Rapid Diagnostic Tests for Visceral Leishmaniasis

    NARCIS (Netherlands)

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen; Khanal, Basudha; Das, Murari; Oliveira, Edward; de Assis, Tália Machado; Costa, Dorcas Lamounier; Bhaskar, Khondaker Rifathassan; Huda, M. Mamun; Hassan, Mukidul; Abdoun, Asim Osman; Awad, Aymen; Osman, Mohamed; Prajapati, Dinesh Kumar; Gidwani, Kamlesh; Tiwary, Puja; Paniago, Anamaria Mello Miranda; Sanchez, Maria Carmen Arroyo; Celeste, Beatriz Julieta; Jacquet, Diane; Magiri, Charles; Muia, A.; Kesusu, J.; Ageed, Al Farazdag; Galal, Nuha; Osman, Osman Salih; Gupta, A. K.; Bimal, Afrad S.; Das, V. N. R.

    2012-01-01

    Background. Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Methods. Commercial VL RDTs

  2. Comparing long-term results of PASAT and SDMT scores in relation to neuropsychological testing in multiple sclerosis

    NARCIS (Netherlands)

    Sonder, J.M.; Burggraaff, J.; Knol, D.L.; Polman, C.H.; Uitdehaag, B.M.J.

    2014-01-01

    Background and objectives: The Symbol Digit Modalities Test (SDMT) shows advantages over the Paced Auditory Serial Addition Test (PASAT) as a cognitive test in patients with multiple sclerosis (MS). To determine which of these tests is most valid and reliable over time as an indicator of the

  3. Wind power integration in island-based smart grid projects : A comparative study between Jeju Smart Grid Test-bed and Smart Grid Gotland

    OpenAIRE

    Piehl, Hampus

    2014-01-01

    Smart grids seem to be the solution to use energy from renewable and intermittent energy sources in an efficient manner. There are many research projects around the world and two of them are Jeju Smart Grid Test-bed and Smart Grid Gotland. They have in common that they are both island-based projects and connected to the Powergrid on the mainland by HVDC-link. The purpose of this thesis is to compare the two projects and find out what challenges and strategies they have related to wind power i...

  4. Comparative tests on the biodegradation of secondary alkane sulphonate, using 14C-labelled preparations

    International Nuclear Information System (INIS)

    Loetzsch, K.; Neufahrt, A.; Taeuber, G.

    1979-01-01

    The biodegradability of 14 C-labelled and unlabelled secondary alkane sulphonates (SAS) and an unlabelled alkyl benzene sulphonate as well as ar ring-labelled sodium-4-(dodecyl-(4'))-benzene sulphonate (LAS) was tested over a period of 12 days with slight germ introduction under aerobic conditions (Hach apparatus). In the 'one-pot method' (simultaneous determination of MBAS, DOC and BSB) with the unlabelled A-surfactants, it was shown that biodegradation of both substances started at different speeds and is almost finished after 15 days in the case of SAS and after 30 days in the case of LAS. The tests with radioactively labelled secondary alkane sulphonate showed that the greater part of the surfactant carbon is quickly degraded to CO 2 . It therefore behaves like uniformly labelled stearate or like a stearyl alcohol ethoxylate uniformly labelled in the alkyl chain. Both were included in the tests as reference substances. The dissimilation processes of the ring-labelled linear alkyl benzene sulphonate are delayed. Here, CO 2 formation started only after a few days. (orig.) [de

  5. Analysis of Semiscale Mod-1 integral test with asymmetrical break (Test S-29-1)

    International Nuclear Information System (INIS)

    Langerman, M.A.

    1977-03-01

    Selected experimental data obtained from Semiscale Mod-1 cold leg break Test S-29-1 and results obtained from analytical codes are analyzed. This test was the first integral blowdown reflood test conducted with the Mod-1 system and was a special test designed specifically to evaluate the sensitivity of the early Mod-1 core thermal response (0 to 5 sec after rupture) to the magnitude and direction of the core flow. To achieve this specific objective in Test S-29-1, the vessel side break area was reduced to approximately one-half the scaled break area associated with a 200 percent cold leg break test. The reduction in break area significantly reduced the core flow reversal that took place immediately after rupture and resulted in periods of positive core flow in the early portion of the test. The results obtained from this test are compared with results obtained from a 200 percent cold leg break test and the effect of core flow on early core thermal response is evaluated. Since Test S-29-1 was the first integral blowdown reflood test conducted with the Mod-1 system, data are also presented through the reflood stage of the test and the results are analyzed. The test data and the core thermal response calculated with the RELAP4 code are also compared

  6. Reflooding phenomena of German PWR estimated from CCTF [Cylindrical Core Test Facility], SCTF [Slab Core Test Facility] and UPTF [Upper Plenum Test Facility] results

    International Nuclear Information System (INIS)

    Murao, Y.; Iguchi, T.; Sugimoto, J.

    1988-09-01

    The reflooding behavior in a PWR with a combined injection type ECCS was studied by comparing the test results from Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF) and Upper Plenum Test Facility (UPTF). Core thermal-hydraulics is discussed mainly based on SCTF test data. In addition, the water accumulation behavior in hot legs and the break-through characteristics at tie plate are discussed

  7. Comparative analysis of automotive paints by laser induced breakdown spectroscopy and nonparametric permutation tests

    International Nuclear Information System (INIS)

    McIntee, Erin; Viglino, Emilie; Rinke, Caitlin; Kumor, Stephanie; Ni Liqiang; Sigman, Michael E.

    2010-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been investigated for the discrimination of automobile paint samples. Paint samples from automobiles of different makes, models, and years were collected and separated into sets based on the color, presence or absence of effect pigments and the number of paint layers. Twelve LIBS spectra were obtained for each paint sample, each an average of a five single shot 'drill down' spectra from consecutive laser ablations in the same spot on the sample. Analyses by a nonparametric permutation test and a parametric Wald test were performed to determine the extent of discrimination within each set of paint samples. The discrimination power and Type I error were assessed for each data analysis method. Conversion of the spectral intensity to a log-scale (base 10) resulted in a higher overall discrimination power while observing the same significance level. Working on the log-scale, the nonparametric permutation tests gave an overall 89.83% discrimination power with a size of Type I error being 4.44% at the nominal significance level of 5%. White paint samples, as a group, were the most difficult to differentiate with the power being only 86.56% followed by 95.83% for black paint samples. Parametric analysis of the data set produced lower discrimination (85.17%) with 3.33% Type I errors, which is not recommended for both theoretical and practical considerations. The nonparametric testing method is applicable across many analytical comparisons, with the specific application described here being the pairwise comparison of automotive paint samples.

  8. In vitro activity of tigecycline and comparators against carbapenem-resistant Enterobacteriaceae in Africa-Middle East countries: TEST 2007-2012.

    Science.gov (United States)

    Renteria, M I; Biedenbach, D J; Bouchillon, S K; Hoban, D J; Raghubir, N; Sajben, P

    2014-09-01

    Multidrug-resistant (MDR) Enterobacteriaceae are an emerging concern for healthcare providers. Infections caused by MDR pathogens are associated with increased costs, length of hospital stay, and morbidity and mortality rates. Carbapenem-resistant Enterobacteriaceae (CRE) continue to increase, and infections with these organisms are observed worldwide not only as hospital-acquired infections but also as community-acquired infections. Increasing antimicrobial resistance dictates the need for continued surveillance studies of common and MDR pathogens. The Tigecycline Evaluation Surveillance Trial (TEST) examined the susceptibility of pathogens isolated in Africa and the Middle East from 2007 to 2012. A total of 4155 Enterobacteriaceae isolates were evaluated to determine the in vitro activity and changes in resistance patterns for tigecycline and comparators. Carbapenem resistance was found in 191 (4.6%) of the isolates tested. Klebsiella pneumoniae was the most common CRE (64.9%), followed by Enterobacter cloacae (14.1%) and Escherichia coli (9.9%). Tigecycline MIC 90 values (minimum inhibitory concentration required to inhibit 90% of the isolates) were 2μg/mL against all of these enteric species, with susceptibility rates of 96.8%, 92.6% and 100%, respectively. Tigecycline had in vitro activity against CRE, with a 95.3% susceptibility rate. Copyright © 2014 International Society for Chemotherapy of Infection and Cancer. Published by Elsevier Ltd. All rights reserved.

  9. Testing and Inclusive Schooling

    DEFF Research Database (Denmark)

    Morin, Anne; Hamre, Bjørn; Ydesen, Christian

    Testing and Inclusive Schooling provides a comparative on seemingly incompatible global agendas and efforts to include all children in the general school system, Thus reducing exclusion. With an examination of the international testing culture and the politics of inclusion currently permeating...

  10. A prospective randomized study to test the transfer of basic psychomotor skills from virtual reality to physical reality in a comparable training setting.

    Science.gov (United States)

    Lehmann, Kai S; Ritz, Joerg P; Maass, Heiko; Cakmak, Hueseyin K; Kuehnapfel, Uwe G; Germer, Christoph T; Bretthauer, Georg; Buhr, Heinz J

    2005-03-01

    To test whether basic skills acquired on a virtual endoscopic surgery simulator are transferable from virtual reality to physical reality in a comparable training setting. For surgical training in laparoscopic surgery, new training methods have to be developed that allow surgeons to first practice in a simulated setting before operating on real patients. A virtual endoscopic surgery trainer (VEST) has been developed within the framework of a joint project. Because of principal limitations of simulation techniques, it is essential to know whether training with this simulator is comparable to conventional training. Devices used were the VEST system and a conventional video trainer (CVT). Two basic training tasks were constructed identically (a) as virtual tasks and (b) as mechanical models for the CVT. Test persons were divided into 2 groups each consisting of 12 novices and 4 experts. Each group carried out a defined training program over the course of 4 consecutive days on the VEST or the CVT, respectively. To test the transfer of skills, the groups switched devices on the 5th day. The main parameter was task completion time. The novices in both groups showed similar learning curves. The mean task completion times decreased significantly over the 4 training days of the study. The task completion times for the control task on Day 5 were significantly lower than on Days 1 and 2. The experts' task completion times were much lower than those of the novices. This study showed that training with a computer simulator, just as with the CVT, resulted in a reproducible training effect. The control task showed that skills learned in virtual reality are transferable to the physical reality of a CVT. The fact that the experts showed little improvement demonstrates that the simulation trains surgeons in basic laparoscopic skills learned in years of practice.

  11. Validity of the RAST for evaluating anaerobic power performance as compared to Wingate test in cycling athletes

    Directory of Open Access Journals (Sweden)

    Marcos Roberto Queiroga

    2013-12-01

    Full Text Available The validity of the Running-based Anaerobic Sprint Test (RAST was investigated to evaluate the anaerobic power performance in comparison to Wingate test in cycling athletes. Ten mountain-bike male cyclists (28.0±7.3 years randomly performed Wingate Test and RAST with two trials each. After several anthropometric measurements, peak power (PP, mean power (MP and fatigue index (FI for RAST and Wingate Test were analyzed using Student's paired t-test, Pearson's linear correlation test (r and Bland and Altman's plots. Results showed that, with the exception of FI (33.8±4.6% vs. 37.8±7.9%; r=0.172, significant differences were detected between the Wingate and RAST tests with regard to PP and MP. Although there was a strong correlation for PP and MP, or rather, 0.831 and 0.714 respectively, agreement of analysis between Wingate and RAST protocols was low. The above suggested that RAST was not appropriate to evaluate the performance of anaerobic power by Wingate test in cycling athletes.

  12. Procalcitonin Test

    Science.gov (United States)

    ... normal" values. By comparing your test results with reference values, you and your healthcare provider can see if ... g., blood culture , urine culture ), lactate , blood gases , complete blood count (CBC) , and cerebrospinal fluid (CSF) analysis . When is ...

  13. Comparing Teleworker Performance, Satisfaction, and Retention in the Joint Interoperability Test Command

    Science.gov (United States)

    Hurd, Danny A.

    2010-01-01

    Telework is becoming one of the best options available to help organizations gain a competitive advantage. When management considers the fluctuating cost of fuel, emphasis on employee flexibility, and need to retain the most-qualified workforce, telework can be advantageous for solving problems. This quantitative comparative (non-experimental)…

  14. Towards a Comparative and International History of School Testing and Accountability

    DEFF Research Database (Denmark)

    Dorn, Sherman; Ydesen, Christian

    2014-01-01

    treated here are identified as a post- colonial perspective, differences and similarities between public and private sector accountability measures, the “engines” promoting the rise, proliferation and implementation of accountability measures, and finally the exploration of the travelling and movement......Abstract: The speed and extent of modern school accountability have obscured the history of testing and accountability. This brief introduction identifies central themes of historical research into educational accountability and recurring traits associated with accountability practices. We hope our...... colleagues and this special issue will also help to identify future research paths in this field. Some of the central themes found in the historical research on educational accountability contained in this special issue are the connections between accountability and the purposes of schooling in a specific...

  15. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  16. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  17. Modelling the Impact and Cost-Effectiveness of Biomarker Tests as Compared with Pathogen-Specific Diagnostics in the Management of Undifferentiated Fever in Remote Tropical Settings.

    Directory of Open Access Journals (Sweden)

    Yoel Lubell

    Full Text Available Malaria accounts for a small fraction of febrile cases in increasingly large areas of the malaria endemic world. Point-of-care tests to improve the management of non-malarial fevers appropriate for primary care are few, consisting of either diagnostic tests for specific pathogens or testing for biomarkers of host response that indicate whether antibiotics might be required. The impact and cost-effectiveness of these approaches are relatively unexplored and methods to do so are not well-developed.We model the ability of dengue and scrub typhus rapid tests to inform antibiotic treatment, as compared with testing for elevated C-Reactive Protein (CRP, a biomarker of host-inflammation. Using data on causes of fever in rural Laos, we estimate the proportion of outpatients that would be correctly classified as requiring an antibiotic and the likely cost-effectiveness of the approaches.Use of either pathogen-specific test slightly increased the proportion of patients correctly classified as requiring antibiotics. CRP testing was consistently superior to the pathogen-specific tests, despite heterogeneity in causes of fever. All testing strategies are likely to result in higher average costs, but only the scrub typhus and CRP tests are likely to be cost-effective when considering direct health benefits, with median cost per disability adjusted life year averted of approximately $48 USD and $94 USD, respectively.Testing for viral infections is unlikely to be cost-effective when considering only direct health benefits to patients. Testing for prevalent bacterial pathogens can be cost-effective, having the benefit of informing not only whether treatment is required, but also as to the most appropriate antibiotic; this advantage, however, varies widely in response to heterogeneity in causes of fever. Testing for biomarkers of host inflammation is likely to be consistently cost-effective despite high heterogeneity, and can also offer substantial reductions in

  18. MetaComp: comprehensive analysis software for comparative meta-omics including comparative metagenomics.

    Science.gov (United States)

    Zhai, Peng; Yang, Longshu; Guo, Xiao; Wang, Zhe; Guo, Jiangtao; Wang, Xiaoqi; Zhu, Huaiqiu

    2017-10-02

    During the past decade, the development of high throughput nucleic sequencing and mass spectrometry analysis techniques have enabled the characterization of microbial communities through metagenomics, metatranscriptomics, metaproteomics and metabolomics data. To reveal the diversity of microbial communities and interactions between living conditions and microbes, it is necessary to introduce comparative analysis based upon integration of all four types of data mentioned above. Comparative meta-omics, especially comparative metageomics, has been established as a routine process to highlight the significant differences in taxon composition and functional gene abundance among microbiota samples. Meanwhile, biologists are increasingly concerning about the correlations between meta-omics features and environmental factors, which may further decipher the adaptation strategy of a microbial community. We developed a graphical comprehensive analysis software named MetaComp comprising a series of statistical analysis approaches with visualized results for metagenomics and other meta-omics data comparison. This software is capable to read files generated by a variety of upstream programs. After data loading, analyses such as multivariate statistics, hypothesis testing of two-sample, multi-sample as well as two-group sample and a novel function-regression analysis of environmental factors are offered. Here, regression analysis regards meta-omic features as independent variable and environmental factors as dependent variables. Moreover, MetaComp is capable to automatically choose an appropriate two-group sample test based upon the traits of input abundance profiles. We further evaluate the performance of its choice, and exhibit applications for metagenomics, metaproteomics and metabolomics samples. MetaComp, an integrative software capable for applying to all meta-omics data, originally distills the influence of living environment on microbial community by regression analysis

  19. Follow-up of treated coeliac patients: Sugar absorption test and intestinal biopsies compared

    NARCIS (Netherlands)

    Uil, J. J.; van Elburg, R. M.; van Overbeek, F. M.; Meyer, J. W.; Mulder, C. J.; Heymans, H. S.

    1996-01-01

    Objective: To determine whether the sugar absorption test (SAT) during follow-up of patients with coeliac disease on a gluten-free diet (GFD) correlates with improvement of the villous architecture of the small intestine. Methods: The SAT was performed in coeliacs at diagnosis and during follow-up

  20. IMOM Field Test Study and Accuracy Verification

    National Research Council Canada - National Science Library

    Levien, Fred

    1998-01-01

    .... It was desired to obtain flight test data for both TAMPS and IMOM in order to compare their ability to accurately predict the effects of Radar Terrain Masking (RTM). It was initially planned to have NPS compare predictive data from both of these systems and then do analysis of how they compared to actual field test data.

  1. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    Science.gov (United States)

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  2. "Comparison of some Structural Analyses Methods used for the Test Pavement in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Baltzer, S.; Zhang, W.; Macdonald, R.

    1998-01-01

    A flexible test pavement, instrumented to measure stresses and strains in the three primary axes with the upper 400 mm of the subgrade, has been constructed and load tested in the Danish Road Testing Machine (RTM). One objective of this research, which is part of the International Pavement Subgrade...... Pressure Cells, Thermistors and Pore Pressure Sensors. Routine monitoring of instrument responses and surface profiles with a Profilometer and FWD/LWD structural testing were undertaken at regular intervals during the construction and load testing programmes.This paper compares various structural analysis...... methods used for the RTM test pavement with data from FWD testing undertaken after the construction and loading programmes. Multilayer linear elastic forward and backcalculation methods, a finite element program and MS Excel spreadsheet based methods are compared....

  3. Test procedure for anion exchange testing with Argonne 10-L solutions

    International Nuclear Information System (INIS)

    Compton, J.A.

    1995-01-01

    Four anion exchange resins will be tested to confirm that they will sorb and release plutonium from/to the appropriate solutions in the presence of other cations. Certain cations need to be removed from the test solutions to minimize adverse behavior in other processing equipment. The ion exchange resins will be tested using old laboratory solutions from Argonne National Laboratory; results will be compared to results from other similar processes for application to all plutonium solutions stored in the Plutonium Finishing Plant

  4. Measuring Gratitude: A Comparative Validation of the Dutch Gratitude Questionnaire (GQ6 and Short Gratitude, Resentment, and Appreciation Test (SGRAT

    Directory of Open Access Journals (Sweden)

    Lilian Jans-Beken

    2015-05-01

    Full Text Available The aim of this article was to validate and compare the Dutch translations of the Gratitude Questionnaire (GQ6 and the Short Gratitude, Resentment, and Appreciation Test (SGRAT in an adult general population sample. In an online survey, 706 respondents ('M 'age = 44, 'SD 'age = 14 completed Dutch versions of the GQ6, the SGRAT, the Satisfaction With Life Scale (SWLS and the Positive Affect and Negative Affect Schedule (PANAS. At six week follow-up, 440 (62% of them ('M' age = 46, 'SD' age = 14 again completed the GQ6-NL and SGRAT-NL. Parallel analyses, exploratory factor analyses and confirmatory factor analyses revealed and confirmed one factor for the GQ6-NL, and three factors for the SGRAT-NL. Internal consistency indices of the GQ6-NL and of the SGRAT-NL were satisfactory. Both questionnaires demonstrated good test-retest reliability. Regression analyses showed, for the total scores on both gratitude questionnaires, positive associations with the SWLS and the Positive Affect Scale, and negative associations with the Negative Affect Scale. The results support the validity of the Dutch GQ6 and SGRAT. These questionnaires can be used to conduct further research of the grateful disposition in Dutch speaking individuals and groups.

  5. Sensitivity and specificity of a hand-held milk electrical conductivity meter compared to the California mastitis test for mastitis in dairy cattle.

    Science.gov (United States)

    Fosgate, G T; Petzer, I M; Karzis, J

    2013-04-01

    Screening tests for mastitis can play an important role in proactive mastitis control programs. The primary objective of this study was to compare the sensitivity and specificity of milk electrical conductivity (EC) to the California mastitis test (CMT) in commercial dairy cattle in South Africa using Bayesian methods without a perfect reference test. A total of 1848 quarter milk specimens were collected from 173 cows sampled during six sequential farm visits. Of these samples, 25.8% yielded pathogenic bacterial isolates. The most frequently isolated species were coagulase negative Staphylococci (n=346), Streptococcus agalactiae (n=54), and Staphylococcus aureus (n=42). The overall cow-level prevalence of mastitis was 54% based on the Bayesian latent class (BLC) analysis. The CMT was more accurate than EC for classification of cows having somatic cell counts >200,000/mL and for isolation of a bacterial pathogen. BLC analysis also suggested an overall benefit of CMT over EC but the statistical evidence was not strong (P=0.257). The Bayesian model estimated the sensitivity and specificity of EC (measured via resistance) at a cut-point of >25 mΩ/cm to be 89.9% and 86.8%, respectively. The CMT had a sensitivity and specificity of 94.5% and 77.7%, respectively, when evaluated at the weak positive cut-point. EC was useful for identifying milk specimens harbouring pathogens but was not able to differentiate among evaluated bacterial isolates. Screening tests can be used to improve udder health as part of a proactive management plan. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Comparing Diagnostic Accuracy of Cognitive Screening Instruments: A Weighted Comparison Approach

    Directory of Open Access Journals (Sweden)

    A.J. Larner

    2013-03-01

    Full Text Available Background/Aims: There are many cognitive screening instruments available to clinicians when assessing patients' cognitive function, but the best way to compare the diagnostic utility of these tests is uncertain. One method is to undertake a weighted comparison which takes into account the difference in sensitivity and specificity of two tests, the relative clinical misclassification costs of true- and false-positive diagnosis, and also disease prevalence. Methods: Data were examined from four pragmatic diagnostic accuracy studies from one clinic which compared the Mini-Mental State Examination (MMSE with the Addenbrooke's Cognitive Examination-Revised (ACE-R, the Montreal Cognitive Assessment (MoCA, the Test Your Memory (TYM test, and the Mini-Mental Parkinson (MMP, respectively. Results: Weighted comparison calculations suggested a net benefit for ACE-R, MoCA, and MMP compared to MMSE, but a net loss for TYM test compared to MMSE. Conclusion: Routine incorporation of weighted comparison or other similar net benefit measures into diagnostic accuracy studies merits consideration to better inform clinicians of the relative value of cognitive screening instruments.

  7. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  8. Comparison of Automated Graphical User Interface Testing Tools

    OpenAIRE

    Gaber, Domen

    2018-01-01

    The thesis presents the analysis of modern tools for automated testing of various web based user interfaces. The purpose of the work is to compare specific test automation solutions and point out the most suitable test automation tool amongst them. One of the main goals of test automation is to gain faster execution when compared to manual testing and overall cost deduction. There are multiple test automation solutions available on the market, which differ in complexity of use, type of o...

  9. Update to: Application of Bayesian decision-making to laboratory testing for Lyme disease and comparison with testing for HIV

    Directory of Open Access Journals (Sweden)

    Cook MJ

    2017-09-01

    Full Text Available Michael J Cook,1 Basant K Puri21Independent researcher, Highcliffe, UK; 2Department of Medicine, Hammersmith Hospital, Imperial College London, London, UKIn our recent Bayesian analysis paper, false-negative results were compared between Lyme disease and HIV using a recommended test algorithm.1 When the two-tier test methodology for Lyme disease was compared with HIV two-stage testing, false negatives could be more than 500 times higher for Lyme disease testing.

  10. CCTF CORE I test results

    International Nuclear Information System (INIS)

    Murao, Yoshio; Sudoh, Takashi; Akimoto, Hajime; Iguchi, Tadashi; Sugimoto, Jun; Fujiki, Kazuo; Hirano, Kenmei

    1982-07-01

    This report presents the results of the following CCTF CORE I tests conducted in FY. 1980. (1) Multi-dimensional effect test, (2) Evaluation model test, (3) FLECHT coupling test. On the first test, one-dimensional treatment of the core thermohydrodynamics was discussed. On the second and third tests, the test results were compared with the results calculated by the evaluation model codes and the results of the corresponding FLECHT-SET test (Run 2714B), respectively. The work was performed under contracts with the Atomic Energy Bureau of Science and Technology Agency of Japan. (author)

  11. Comparative study of HbA1c and fasting plasma glucose vs the oral glucose tolerance test for diagnosis of diabetes in people with tuberculosis

    DEFF Research Database (Denmark)

    Aftab, H.; Ambreen, A.; Jamil, M.

    2017-01-01

    Aim: To compare HbA1c and fasting plasma glucose assessment, with the 2-h oral glucose tolerance test as reference, in screening for diabetes in people with turberculosis. Methods: Individuals (N=268) with newly diagnosed smear-positive tuberculosis were screened for diabetes at a tertiary hospital...... in Lahore, Pakistan. Diabetes diagnosis was based on WHO criteria: thresholds were ≥48 mmol/mol (≥6.5%) for HbA1c and ≥7.0mmol/l for fasting plasma glucose. Results: The proportion of participants diagnosed with diabetes was 4.9% (n =13) by oral glucose tolerance test, while 11.9% (n =32) and 14.6% (n =39...... the two tests (P=0.07). Conclusions: HbA1c and fasting plasma glucose performed equally in terms of diagnosing new diabetes cases in individuals with tuberculosis, but the proportion of participants falsely classified as positive was higher for fasting plasma glucose. This may be explained by acute blood...

  12. Effects of white noise on Callsign Acquisition Test and Modified Rhyme Test scores.

    Science.gov (United States)

    Blue-Terry, Misty; Letowski, Tomasz

    2011-02-01

    The Callsign Acquisition Test (CAT) is a speech intelligibility test developed by the US Army Research Laboratory. The test has been used to evaluate speech transmission through various communication systems but has not been yet sufficiently standardised and validated. The aim of this study was to compare CAT and Modified Rhyme Test (MRT) performance in the presence of white noise across a range of signal-to-noise ratios (SNRs). A group of 16 normal-hearing listeners participated in the study. The speech items were presented at 65 dB(A) in the background of white noise at SNRs of -18, -15, -12, -9 and -6 dB. The results showed a strong positive association (75.14%) between the two tests, but significant differences between the CAT and MRT absolute scores in the range of investigated SNRs. Based on the data, a function to predict CAT scores based on existing MRT scores and vice versa was formulated. STATEMENT OF RELEVANCE: This work compares performance data of a common speech intelligibility test (MRT) with a new test (CAT) in the presence of white noise. The results here can be used as a part of the standardisation procedures and provide insights to the predictive capabilities of the CAT to quantify speech intelligibility communication in high-noise military environments.

  13. Experiences with novel approaches in earthworm testing alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K.; Lindemann, M.; Simon, M. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany)

    2005-11-01

    Goal, Scope and Background. The earthworm avoidance test is a sensitive screening test. Currently, two test designs, a two-chamber system and a six-chamber system, are under standardization. In the scope of the present study, the two test systems are compared. To assess the results, two procedures are applied, which are based on a threshold value and a statistical method. Moreover, the sensitivity of the avoidance test is compared with the sensitivity of the reproduction test. Methods. The avoidance behaviour of E. fetida towards five chemicals (Cd, Cu, PCP, TBT, TNT) was tested in a sandy and a loamy soil. The ecotoxicological test was performed according to the draft guideline ISO/DIS 17512-1. The results were compared with the number of offspring determined in the reproduction test carried out according to ISO 11268-2. Results and Discussion. The results demonstrate that the avoidance behaviour towards organic chemicals and heavy metals is a suitable screening method showing first tendencies of a chemical's effects on the habitat function of soils. Effects caused by chemical substances become visible at low concentrations and within short test periods. The sensitivity of the reproduction test and the avoidance test is principally comparable; in some cases, the avoidance test showed more sensitive reactions. The dose-response-relationships were more pronounced in the two-chamber test than in the six-chamber-system. Recommendation and Outlook. The two-chamber-system proved to be more feasible than the six-chamber-system. As the sensitivity of the avoidance test and the reproduction test is comparable, the avoidance test can be considered as a suitable screening test. A possible field of application may be the selection of soil samples for which the reproduction assay seems necessary. To assess contaminated or remediated soils, the earthworm reproduction test is recommended as an indicator for the habitat function of the soils. To reduce costs, the avoidance

  14. Detection of thrombocytic antibodies with the direct and indirect haemolysis inhibition test and the radioimmuno-Coombs test

    International Nuclear Information System (INIS)

    Mettenboerger, D.; Vith, E.

    1982-01-01

    Methods of application of the direct and indirect haemolysis inhibition test were studied in order to optimise the test parameters: The ultimate aim was to standardize the test method and compare its sensitivity in detecting various platelet antibodies with platelet indirect radioactive Coombs-test and the platelet immunofluorescence test. (orig.) [de

  15. Development and testing of new upper-limb prosthetic devices: research designs for usability testing.

    Science.gov (United States)

    Resnik, Linda

    2011-01-01

    The purposes of this article are to describe usability testing and introduce designs and methods of usability testing research as it relates to upper-limb prosthetics. This article defines usability, describes usability research, discusses research approaches to and designs for usability testing, and highlights a variety of methodological considerations, including sampling, sample size requirements, and usability metrics. Usability testing is compared with other types of study designs used in prosthetic research.

  16. Empirical Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    This document includes the empirical specification on the IEA task of evaluation building energy simulation computer programs for the Double Skin Facades (DSF) constructions. There are two approaches involved into this procedure, one is the comparative approach and another is the empirical one. I....... In the comparative approach the outcomes of different software tools are compared, while in the empirical approach the modelling results are compared with the results of experimental test cases....

  17. A rule-based software test data generator

    Science.gov (United States)

    Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II

    1991-01-01

    Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.

  18. Reliability Analysis and Test Planning using CAPO-Test for Existing Structures

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Engelund, S.; Faber, Michael Havbro

    2000-01-01

    Evaluation of the reliability of existing concrete structures often requires that the compressive strength of the concrete is estimated on the basis of tests performed with concrete samples from the structure considered. In this paper the CAPO-test method is considered. The different sources...... of uncertainty related to this method are described. It is shown how the uncertainty in the transformation from the CAPO-test results to estimates of the concrete strength can be modeled. Further, the statistical uncertainty is modeled using Bayesian statistics. Finally, it is shown how reliability-based optimal...... planning of CAPO-tests can be performed taking into account the expected costs due to the CAPO-tests and possible repair or failure of the structure considered. An illustrative example is presented where the CAPO-test is compared with conventional concrete cylinder compression tests performed on cores...

  19. A Network Meta-Analysis Comparing Effects of Various Antidepressant Classes on the Digit Symbol Substitution Test (DSST) as a Measure of Cognitive Dysfunction in Patients with Major Depressive Disorder.

    Science.gov (United States)

    Baune, Bernhard T; Brignone, Mélanie; Larsen, Klaus Groes

    2018-02-01

    Major depressive disorder is a common condition that often includes cognitive dysfunction. A systematic literature review of studies and a network meta-analysis were carried out to assess the relative effect of antidepressants on cognitive dysfunction in major depressive disorder. MEDLINE, Embase, Cochrane, CDSR, and PsychINFO databases; clinical trial registries; and relevant conference abstracts were searched for randomized controlled trials assessing the effects of antidepressants/placebo on cognition. A network meta-analysis comparing antidepressants was conducted using a random effects model. The database search retrieved 11337 citations, of which 72 randomized controlled trials from 103 publications met the inclusion criteria. The review identified 86 cognitive tests assessing the effect of antidepressants on cognitive functioning. However, the Digit Symbol Substitution Test, which targets multiple domains of cognition and is recognized as being sensitive to change, was the only test that was used across 12 of the included randomized controlled trials and that allowed the construction of a stable network suitable for the network meta-analysis. The interventions assessed included selective serotonin reuptake inhibitors, serotonin-norepinephrine reuptake inhibitors, and other non-selective serotonin reuptake inhibitors/serotonin-norepinephrine reuptake inhibitors. The network meta-analysis using the Digit Symbol Substitution Test showed that vortioxetine was the only antidepressant that improved cognitive dysfunction on the Digit Symbol Substitution Test vs placebo {standardized mean difference: 0.325 (95% CI = 0.120; 0.529, P=.009}. Compared with other antidepressants, vortioxetine was statistically more efficacious on the Digit Symbol Substitution Test vs escitalopram, nortriptyline, and the selective serotonin reuptake inhibitor and tricyclic antidepressant classes. This study highlighted the large variability in measures used to assess cognitive functioning

  20. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  1. Testing feedback message framing and comparators to address prescribing of high-risk medications in nursing homes: protocol for a pragmatic, factorial, cluster-randomized trial.

    Science.gov (United States)

    Ivers, Noah M; Desveaux, Laura; Presseau, Justin; Reis, Catherine; Witteman, Holly O; Taljaard, Monica K; McCleary, Nicola; Thavorn, Kednapa; Grimshaw, Jeremy M

    2017-07-14

    Audit and feedback (AF) interventions that leverage routine administrative data offer a scalable and relatively low-cost method to improve processes of care. AF interventions are usually designed to highlight discrepancies between desired and actual performance and to encourage recipients to act to address such discrepancies. Comparing to a regional average is a common approach, but more recipients would have a discrepancy if compared to a higher-than-average level of performance. In addition, how recipients perceive and respond to discrepancies may depend on how the feedback itself is framed. We aim to evaluate the effectiveness of different comparators and framing in feedback on high-risk prescribing in nursing homes. This is a pragmatic, 2 × 2 factorial, cluster-randomized controlled trial testing variations in the comparator and framing on the effectiveness of quarterly AF in changing high-risk prescribing in nursing homes in Ontario, Canada. We grouped homes that share physicians into clusters and randomized these clusters into the four experimental conditions. Outcomes will be assessed after 6 months; all primary analyses will be by intention-to-treat. The primary outcome (monthly number of high-risk medications received by each patient) will be analysed using a general linear mixed effects regression model. We will present both four-arm and factorial analyses. With 160 clusters and an average of 350 beds per cluster, assuming no interaction and similar effects for each intervention, we anticipate 90% power to detect an absolute mean difference of 0.3 high-risk medications prescribed. A mixed-methods process evaluation will explore potential mechanisms underlying the observed effects, exploring targeted constructs including intention, self-efficacy, outcome expectations, descriptive norms, and goal prioritization. An economic analysis will examine cost-effectiveness analysis from the perspective of the publicly funded health care system. This protocol

  2. Experiments on the Model Testing of the 2nd Phase of Die Casting Process Compared with the Results of Numerical Simulation

    Directory of Open Access Journals (Sweden)

    Dańko R.

    2015-12-01

    Full Text Available Experiments of filling the model moulds cavity of various inner shapes inserted in rectangular cavity of the casting die (dimensions: 280 mm (height × 190 mm (width × 10 mm (depth by applying model liquids of various density and viscosity are presented in the paper. Influence of die venting as well as inlet system area and inlet velocity on the volumetric rate of filling of the model liquid - achieved by means of filming the process in the system of a cold-chamber casting die was tested. Experiments compared with the results of simulation performed by means of the calculation module Novacast (Novaflow&Solid for the selected various casting conditions - are also presented in the paper.

  3. Comparative study of colloidal gold and quantum dots as labels for multiplex screening tests for multi-mycotoxin detection

    Energy Technology Data Exchange (ETDEWEB)

    Foubert, Astrid, E-mail: astrid.foubert@hotmail.com; Beloglazova, Natalia V.; De Saeger, Sarah

    2017-02-22

    Quantum dots (QDs) and colloidal gold nanoparticles (CG) were evaluated as labels for multiplex lateral flow immunoassay (LFIA) for determination of mycotoxins deoxynivalenol (DON), zearalenone (ZEN) and T2/HT2-toxin (T2/HT2) in cereal matrices. Both developed assays were based on the same immunoreagents (except for the labels), therefore their analytical characteristics could be objectively compared. For both LFIAs antigens (DON-ovalbumin (OVA), ZEN-OVA and T2-OVA) and rabbit anti-mouse immunoglobulin were immobilized on a nitrocellulose membrane as three test lines and one control line, respectively. Depending on the LFIA, monoclonal antibodies (mAb) against DON, ZEN and T2 were conjugated with CdSeS/ZnS QDs or CG. T2 and HT2 were detected by one test line (T2-OVA) with an anti-T2 mAb which showed 110% cross-reactivity with HT2. Both tests were developed in accordance with the legal limits and were developed in such a way that they had the same cut-off limits of 1000 μg kg{sup −1}, 80 μg kg{sup −1} and 80 μg kg{sup −1} for DON, ZEN and T2/HT2, respectively in order to allow a correct comparison. Applicability of these assays was demonstrated by analysis of naturally contaminated wheat samples. The results demonstrate that both the LFIAs can be used as rapid, cost-effective and convenient qualitative tool for on-site screening for simultaneous detection of DON, ZEN and HT2/T2 in wheat without special instrumentation. However, the QD-based LFIA consumed less immunoreagents and was more sensitive and economically beneficial. In addition, the results were easier to interpret, resulting in a lower false negative rate (<5%) which was in good agreement with Commission Decision 2002/657/EC regarding the performance of analytical methods intended for screening purposes. - Highlights: • Development of colloidal gold- and quantum dot-based multiplex lateral flow immunoassay. • Lateral flow immunoassays allow simultaneous detection of four mycotoxins.

  4. Negative HPV screening test predicts low cervical cancer risk better than negative Pap test

    Science.gov (United States)

    Based on a study that included more than 1 million women, investigators at NCI have determined that a negative test for HPV infection compared to a negative Pap test provides greater safety, or assurance, against future risk of cervical cancer.

  5. Investigation of the ElectroPuls E3000 Test Machine for Fatigue Testing of Structural Materials

    Science.gov (United States)

    2016-12-01

    potential to use high frequencies to reduce test time significantly (at, for example, four times the maximum frequency possible on a servo- hydraulic ...crack growth rate data (at a frequency of 10 Hz) that was consistent with previous testing performed on servo- hydraulic testing machines (at a frequency...operate at frequencies "over 100 Hz" and has the potential to increase efficiency by decreasing test time, as compared with a servo- hydraulic test machine

  6. Validity of eyeball estimation for range of motion during the cervical flexion rotation test compared to an ultrasound-based movement analysis system.

    Science.gov (United States)

    Schäfer, Axel; Lüdtke, Kerstin; Breuel, Franziska; Gerloff, Nikolas; Knust, Maren; Kollitsch, Christian; Laukart, Alex; Matej, Laura; Müller, Antje; Schöttker-Königer, Thomas; Hall, Toby

    2018-08-01

    Headache is a common and costly health problem. Although pathogenesis of headache is heterogeneous, one reported contributing factor is dysfunction of the upper cervical spine. The flexion rotation test (FRT) is a commonly used diagnostic test to detect upper cervical movement impairment. The aim of this cross-sectional study was to investigate concurrent validity of detecting high cervical ROM impairment during the FRT by comparing measurements established by an ultrasound-based system (gold standard) with eyeball estimation. Secondary aim was to investigate intra-rater reliability of FRT ROM eyeball estimation. The examiner (6 years experience) was blinded to the data from the ultrasound-based device and to the symptoms of the patients. FRT test result (positive or negative) was based on visual estimation of range of rotation less than 34° to either side. Concurrently, range of rotation was evaluated using the ultrasound-based device. A total of 43 subjects with headache (79% female), mean age of 35.05 years (SD 13.26) were included. According to the International Headache Society Classification 23 subjects had migraine, 4 tension type headache, and 16 multiple headache forms. Sensitivity and specificity were 0.96 and 0.89 for combined rotation, indicating good concurrent reliability. The area under the ROC curve was 0.95 (95% CI 0.91-0.98) for rotation to both sides. Intra-rater reliability for eyeball estimation was excellent with Fleiss Kappa 0.79 for right rotation and left rotation. The results of this study indicate that the FRT is a valid and reliable test to detect impairment of upper cervical ROM in patients with headache.

  7. Pancreatic exocrine function testing

    International Nuclear Information System (INIS)

    Goff, J.S.

    1981-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and para-aminobenzoic acid bound to a dipeptide. Of all these tests the secretin stimulation test is the most accurate and reliable if done by experienced personnel. However, the indirect tests are simpler to do and appear to be comparable to the secretin test at detecting pancreatic exocrine insufficiency. These indirect tests are becoming clinically available and clinicians should familiarize themselves with the strengths and weaknesses of each

  8. Six rapid tests for direct detection of Clostridium difficile and its toxins in fecal samples compared with the fibroblast cytotoxicity assay.

    Science.gov (United States)

    Turgeon, David K; Novicki, Thomas J; Quick, John; Carlson, LaDonna; Miller, Pat; Ulness, Bruce; Cent, Anne; Ashley, Rhoda; Larson, Ann; Coyle, Marie; Limaye, Ajit P; Cookson, Brad T; Fritsche, Thomas R

    2003-02-01

    Clostridium difficile is one of the most frequent causes of nosocomial gastrointestinal disease. Risk factors include prior antibiotic therapy, bowel surgery, and the immunocompromised state. Direct fecal analysis for C. difficile toxin B by tissue culture cytotoxin B assay (CBA), while only 60 to 85% sensitive overall, is a common laboratory method. We have used 1,003 consecutive, nonduplicate fecal samples to compare six commercially available immunoassays (IA) for C. difficile detection with CBA: Prima System Clostridium difficile Tox A and VIDAS Clostridium difficile Tox A II, which detect C. difficile toxin A; Premier Cytoclone A/B and Techlab Clostridium difficile Tox A/B, which detect toxins A and B; and ImmunoCard Clostridium difficile and Triage Micro C. difficile panels, which detect toxin A and a species-specific antigen. For all tests, Triage antigen was most sensitive (89.1%; negative predictive value [NPV] = 98.7%) while ImmunoCard was most specific (99.7%; positive predictive value [PPV] = 95.0%). For toxin tests only, Prima System had the highest sensitivity (82.2%; NPV = 98.0%) while ImmunoCard had the highest specificity (99.7%; PPV = 95.0%). Hematopoietic stem cell transplant (HSCT) patients contributed 44.7% of all samples tested, and no significant differences in sensitivity or specificity were noted between HSCT and non-HSCT patients. IAs, while not as sensitive as direct fecal CBA, produce reasonable predictive values, especially when both antigen and toxin are detected. They also offer significant advantages over CBA in terms of turnaround time and ease of use.

  9. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design

    International Nuclear Information System (INIS)

    Potthoff, Annegret; Meißner, Tobias; Weil, Mirco; Kühnel, Dana

    2015-01-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing. (paper)

  10. Corrosion performance tests for reinforcing steel in concrete : test procedures.

    Science.gov (United States)

    2009-09-01

    The existing test method to assess the corrosion performance of reinforcing steel embedded in concrete, mainly : ASTM G109, is labor intensive, time consuming, slow to provide comparative results, and often expensive. : However, corrosion of reinforc...

  11. Spinal cord testing: auditing for quality assurance.

    Science.gov (United States)

    Marr, J A; Reid, B

    1991-04-01

    A quality assurance audit of spinal cord testing as documented by staff nurses was carried out. Twenty-five patient records were examined for accuracy of documented testing and compared to assessments performed by three investigators. A pilot study established interrater reliability of a tool that was designed especially for this study. Results indicated staff nurses failed to meet pre-established 100% standard in all categories of testing when compared with investigator's findings. Possible reasons for this disparity are discussed as well as indications for modifications in the spinal testing record, teaching program and preset standards.

  12. OECD Guidelines for the Testing of Chemicals, Test No. 226: Predatory mite (Hypoaspis (Geolaelaps) aculeifer) reproduction test in soil

    DEFF Research Database (Denmark)

    Römbke, L. Becker, B. Dark, Th. Moser, N. Halsall, W. Powley, A. Ruf, C. Scholer, E. Smit, P. Wege, N. Zenz m.fl., J.; Krogh, Paul Henning

    2008-01-01

    This Test Guideline describes a method to assess the effects of chemical substances in soil on the reproductive output of the soil mite species Hypoaspis (Geolaelaps) aculeifer Canestrini (Acari: Laelapidae). It can be used for water soluble or insoluble substances, but not with volatile substances...... replicates for each test concentrations and six to eight control replicates, of 10 animals each, are recommended. At 20 oC, the test lasts 14 days after introducing the females, which usually allows the control offspring to reach the deutonymph stage. The number of surviving females (mortality ...% for a valid test) and the number of juveniles per test vessel (at least 50 for a valid test) are determined. The fecundity of the mites exposed to the test substance is compared to that of controls in order to determine the ECx (e.g. EC10, EC50) or the No Observed Effect Concentration (NOEC). Any observed...

  13. How does cognition evolve? Phylogenetic comparative psychology

    Science.gov (United States)

    Matthews, Luke J.; Hare, Brian A.; Nunn, Charles L.; Anderson, Rindy C.; Aureli, Filippo; Brannon, Elizabeth M.; Call, Josep; Drea, Christine M.; Emery, Nathan J.; Haun, Daniel B. M.; Herrmann, Esther; Jacobs, Lucia F.; Platt, Michael L.; Rosati, Alexandra G.; Sandel, Aaron A.; Schroepfer, Kara K.; Seed, Amanda M.; Tan, Jingzhi; van Schaik, Carel P.; Wobber, Victoria

    2014-01-01

    Now more than ever animal studies have the potential to test hypotheses regarding how cognition evolves. Comparative psychologists have developed new techniques to probe the cognitive mechanisms underlying animal behavior, and they have become increasingly skillful at adapting methodologies to test multiple species. Meanwhile, evolutionary biologists have generated quantitative approaches to investigate the phylogenetic distribution and function of phenotypic traits, including cognition. In particular, phylogenetic methods can quantitatively (1) test whether specific cognitive abilities are correlated with life history (e.g., lifespan), morphology (e.g., brain size), or socio-ecological variables (e.g., social system), (2) measure how strongly phylogenetic relatedness predicts the distribution of cognitive skills across species, and (3) estimate the ancestral state of a given cognitive trait using measures of cognitive performance from extant species. Phylogenetic methods can also be used to guide the selection of species comparisons that offer the strongest tests of a priori predictions of cognitive evolutionary hypotheses (i.e., phylogenetic targeting). Here, we explain how an integration of comparative psychology and evolutionary biology will answer a host of questions regarding the phylogenetic distribution and history of cognitive traits, as well as the evolutionary processes that drove their evolution. PMID:21927850

  14. How does cognition evolve? Phylogenetic comparative psychology.

    Science.gov (United States)

    MacLean, Evan L; Matthews, Luke J; Hare, Brian A; Nunn, Charles L; Anderson, Rindy C; Aureli, Filippo; Brannon, Elizabeth M; Call, Josep; Drea, Christine M; Emery, Nathan J; Haun, Daniel B M; Herrmann, Esther; Jacobs, Lucia F; Platt, Michael L; Rosati, Alexandra G; Sandel, Aaron A; Schroepfer, Kara K; Seed, Amanda M; Tan, Jingzhi; van Schaik, Carel P; Wobber, Victoria

    2012-03-01

    Now more than ever animal studies have the potential to test hypotheses regarding how cognition evolves. Comparative psychologists have developed new techniques to probe the cognitive mechanisms underlying animal behavior, and they have become increasingly skillful at adapting methodologies to test multiple species. Meanwhile, evolutionary biologists have generated quantitative approaches to investigate the phylogenetic distribution and function of phenotypic traits, including cognition. In particular, phylogenetic methods can quantitatively (1) test whether specific cognitive abilities are correlated with life history (e.g., lifespan), morphology (e.g., brain size), or socio-ecological variables (e.g., social system), (2) measure how strongly phylogenetic relatedness predicts the distribution of cognitive skills across species, and (3) estimate the ancestral state of a given cognitive trait using measures of cognitive performance from extant species. Phylogenetic methods can also be used to guide the selection of species comparisons that offer the strongest tests of a priori predictions of cognitive evolutionary hypotheses (i.e., phylogenetic targeting). Here, we explain how an integration of comparative psychology and evolutionary biology will answer a host of questions regarding the phylogenetic distribution and history of cognitive traits, as well as the evolutionary processes that drove their evolution.

  15. Irradiation Effects Test Series: Test IE-3. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, L. C.; Allison, C. M.; Croucher, D. W.; Ploger, S. A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m/sup 2/. After a flow reduction to 2120 kg/s-m/sup 2/, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions.

  16. In-place testing of hydraulic snubbers

    International Nuclear Information System (INIS)

    Raymont, J.M. Jr.

    1986-01-01

    Over the last few years, an increasing number of utilities have implemented periodic in-service inspection (ISI) programs of their hydraulic snubbers. This thrust has caused the nuclear power industry to seek cost-effective means of testing hydraulic snubbers. This paper reviews the following aspects of in-place testing and develops a technical justification for its use as a viable alternative to test bench testing. (1) A detailed examination of how in-place testing works is provided. Discussed are the hydraulic principles, fluid flow paths, and snubber test setup. (2) A comparison of the test bench and in-place test machines is provided. The discussion reviews the similarities and differences between the two test methods as well as the test results. (3) The need for correlation of in-place test results back to test bench data with a snubber footprint is discussed. (4) The issue of partial load testing with extrapolation to full load testing is discussed and compared with full load testing. The hydraulic principles as well as the costs and benefits of partial load versus full load testing are compared. (5) In-place test machine technology is reviewed. The operating principles, accuracies, and limitations are presented. (6) Actual test data are provided and reviewed on a test-by-test basis. (7) Lessons learned from actual in-place test jobs are reviewed. (8) In-place test procedures and calibration practices are outlined to illustrate the nature of the required planning on the part of the utility

  17. A comparative study of two food model systems to test the survival of Campylobacter jejuni at -18 degrees C

    DEFF Research Database (Denmark)

    Birk, Tina; Rosenquist, Hanne; Brondsted, L.

    2006-01-01

    The survival of Campylobacter jejuni NCTC 11168 was tested at freezing conditions (-18 degrees C) over a period of 32 days in two food models that simulated either (i) the chicken skin surface (skin model) or (ii) the chicken juice in and around a broiler carcass (liquid model). In the skin model...... NCTC 11168 cells was slower when suspended in chicken juice than in BHIB. After freezing for 32 days, the reductions in the cell counts were 1.5 log CFU/ml in chicken juice and 3.5 log CFU/ml in BHIB. After the same time of freezing but when inoculated onto chicken skin, C. jejuni NCTC 11168...... was reduced by 2.2 log units when inoculated in chicken juice and 3.2 log units when inoculated into BHIB. For both models, the major decrease occurred within the first 24 h of freezing. The results obtained in the liquid model with chicken juice were comparable to the reductions of Campylobacter observed...

  18. BRCA mutation carrier detection. A model-based cost-effectiveness analysis comparing the traditional family history approach and the testing of all patients with breast cancer

    Science.gov (United States)

    Norum, Jan; Grindedal, Eli Marie; Heramb, Cecilie; Karsrud, Inga; Ariansen, Sarah Louise; Undlien, Dag Erik; Schlichting, Ellen; Mæhle, Lovise

    2018-01-01

    Background Identification of BRCA mutation carriers among patients with breast cancer (BC) involves costs and gains. Testing has been performed according to international guidelines, focusing on family history (FH) of breast and/or ovarian cancer. An alternative is testing all patients with BC employing sequencing of the BRCA genes and Multiplex Ligation Probe Amplification (MLPA). Patients and methods A model-based cost-effectiveness analysis, employing data from Oslo University Hospital, Ullevål (OUH-U) and a decision tree, was done. The societal and the healthcare perspectives were focused and a lifetime perspective employed. The comparators were the traditional FH approach used as standard of care at OUH-U in 2013 and the intervention (testing all patients with BC) performed in 2014 and 2015 at the same hospital. During the latter period, 535 patients with BC were offered BRCA testing with sequencing and MLPA. National 2014 data on mortality rates and costs were implemented, a 3% discount rate used and the costing year was 2015. The incremental cost-effectiveness ratio was calculated in euros (€) per life-year gained (LYG). Results The net healthcare cost (healthcare perspective) was €40 503/LYG. Including all resource use (societal perspective), the cost was €5669/LYG. The univariate sensitivity analysis documented the unit cost of the BRCA test and the number of LYGs the prominent parameters affecting the result. Diagnostic BRCA testing of all patients with BC was superior to the FH approach and cost-effective within the frequently used thresholds (healthcare perspective) in Norway (€60 000–€80 000/LYG). PMID:29682331

  19. BRCA mutation carrier detection. A model-based cost-effectiveness analysis comparing the traditional family history approach and the testing of all patients with breast cancer.

    Science.gov (United States)

    Norum, Jan; Grindedal, Eli Marie; Heramb, Cecilie; Karsrud, Inga; Ariansen, Sarah Louise; Undlien, Dag Erik; Schlichting, Ellen; Mæhle, Lovise

    2018-01-01

    Identification of BRCA mutation carriers among patients with breast cancer (BC) involves costs and gains. Testing has been performed according to international guidelines, focusing on family history (FH) of breast and/or ovarian cancer. An alternative is testing all patients with BC employing sequencing of the BRCA genes and Multiplex Ligation Probe Amplification (MLPA). A model-based cost-effectiveness analysis, employing data from Oslo University Hospital, Ullevål (OUH-U) and a decision tree, was done. The societal and the healthcare perspectives were focused and a lifetime perspective employed. The comparators were the traditional FH approach used as standard of care at OUH-U in 2013 and the intervention (testing all patients with BC) performed in 2014 and 2015 at the same hospital. During the latter period, 535 patients with BC were offered BRCA testing with sequencing and MLPA. National 2014 data on mortality rates and costs were implemented, a 3% discount rate used and the costing year was 2015. The incremental cost-effectiveness ratio was calculated in euros (€) per life-year gained (LYG). The net healthcare cost (healthcare perspective) was €40 503/LYG. Including all resource use (societal perspective), the cost was €5669/LYG. The univariate sensitivity analysis documented the unit cost of the BRCA test and the number of LYGs the prominent parameters affecting the result.Diagnostic BRCA testing of all patients with BC was superior to the FH approach and cost-effective within the frequently used thresholds (healthcare perspective) in Norway (€60 000-€80 000/LYG).

  20. To compare the accuracy of Prayer's sign and Mallampatti test in predicting difficult intubation in Diabetic patients

    International Nuclear Information System (INIS)

    Baig, M. M. A.; Khan, F. H.

    2014-01-01

    Objective: To determine the accuracy of Prayer's sign and Mallampatti test in predicting difficult endotracheal intubation in diabetic patients. Methods: The cross-sectional study was performed at Aga Khan University Hospital, Karachi, over a period from January 2009 to April 2010, and comprised 357 patients who required endotracheal intubation for elective surgical procedures. Prayer's sign and Mallampatti tests were performed for the assessment of airway by trained observers. Ease or difficulty of laryngoscopy after the patient was fully anaesthetised with standard technique were observed and laryngoscopic view of first attempt was rated according to Cormack-Lehan grade of intubation. SPSS 15 was used for statistical analysis. Results: Of the 357 patients, 125(35%) were classified as difficult to intubate. Prayer's sign showed significantly lower accuracy, positive and negative predictive values than Mallampatti test. The sensitivity of Prayer's sign was lower 29.6 (95% Confidence Interval, 21.9-38.5) than Mallampatti test 79.3 (95% confidence interval, 70.8-85.7) while specificity of both the tests was not found to be significantly different. Conclusion: Prayer's sign is not acceptable as a single best bedside test for prediction of difficult intubation. (author)

  1. Comparative thermal cyclic test of different beryllium grades previously subjected to simulated disruption loads

    International Nuclear Information System (INIS)

    Gervash, A.; Giniyatulin, R.; Mazul, I.

    1999-01-01

    Considering beryllium as plasma facing armour this paper presents recent results obtained in Russia. A special process of joining beryllium to a Cu-alloy material structure is described and recent results of thermal cycling tests of such joints are presented. Summarizing the results, the authors show that a Cu-alloy heat sink structure armoured with beryllium can survive high heat fluxes (≥10 MW/m 2 ) during 1000 heating/cooling cycles without serious damage to the armour material and its joint. The principal feasibility of thermal cycling of beryllium grades and their joints directly in the core of a nuclear reactor is demonstrated and the main results of this test are presented. The paper also describes the thermal cycling of different beryllium grades having cracks initiated by previously applied high heat loads simulating plasma disruptions. (orig.)

  2. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  3. Compared behaviour of stainless steel and titanium tests lines for a L.H.H. grill launcher

    International Nuclear Information System (INIS)

    Rey, G.; Briand, P.; David, C.; Lamboley, G.; Moulin, D.; Tonon, G.

    1982-09-01

    The choice of the material as first wall of a grill is of major importance. It must satisfy eventually conficting demands: (i) mean secondary emission coefficient low enough to avoid multipactor effect, (ii) low gas absorption and desorption and (iii) easy manufacturing. Then two test lines, one made of pure titanium, the other made of 304 L stainless steel have been tested at RF power greater than 300 kW during 150 ms at 1,25 GHz. As reported in a previous paper, 360 kW have been transmitted in the titanium test line without or with a very slight change in phase between incident an transmitted wave ( 0 ) after application of low pressure argon glow discharges. We now report the first results obtained on a stainless steel test line after the use of the same conditioning procedure (baking and argon glow discharges) and the effects of a static magnetic field superimposed in the reduced size sections of the line (B parallel to the large dimension of the waveguide)

  4. Hemagglutination treponemal test for syphilis.

    OpenAIRE

    Friedly, G; Zartarian, M V; Wood, J C; Floyd, C M; Peterson, E M; de la Maza, L M

    1983-01-01

    Sera from 290 hospital patients were tested to compare the sensitivity, specificity, and reproducibility of the hemagglutination treponemal test for syphilis (HATTS) with the fluorescent treponemal antibody absorption test (FTA-ABS). Complete agreement was obtained between the methods when 142 syphilitic sera from patients with various stages of syphilis were tested. By using clinical histories, the specificity with 148 nonsyphilitic sera was determined to be 100% for the HATTS and 96.6% (143...

  5. Demographically corrected norms for African Americans and Caucasians on the Hopkins Verbal Learning Test-Revised, Brief Visuospatial Memory Test-Revised, Stroop Color and Word Test, and Wisconsin Card Sorting Test 64-Card Version.

    Science.gov (United States)

    Norman, Marc A; Moore, David J; Taylor, Michael; Franklin, Donald; Cysique, Lucette; Ake, Chris; Lazarretto, Deborah; Vaida, Florin; Heaton, Robert K

    2011-08-01

    Memory and executive functioning are two important components of clinical neuropsychological (NP) practice and research. Multiple demographic factors are known to affect performance differentially on most NP tests, but adequate normative corrections, inclusive of race/ethnicity, are not available for many widely used instruments. This study compared demographic contributions for widely used tests of verbal and visual learning and memory (Brief Visual Memory Test-Revised, Hopkins Verbal Memory Test-Revised) and executive functioning (Stroop Color and Word Test, Wisconsin Card Sorting Test-64) in groups of healthy Caucasians (n = 143) and African Americans (n = 103). Demographic factors of age, education, gender, and race/ethnicity were found to be significant factors on some indices of all four tests. The magnitude of demographic contributions (especially age) was greater for African Americans than for Caucasians on most measures. New, demographically corrected T-score formulas were calculated for each race/ethnicity. The rates of NP impairment using previously published normative standards significantly overestimated NP impairment in African Americans. Utilizing the new demographic corrections developed and presented herein, NP impairment rates were comparable between the two race/ethnicities and were unrelated to the other demographic characteristics (age, education, gender) in either race/ethnicity group. Findings support the need to consider extended demographic contributions to neuropsychological test performance in clinical and research settings.

  6. What drives the comparability effect of mandatory IFRS adoption?

    OpenAIRE

    Stefano Cascino; Joachim Gassen

    2015-01-01

    We investigate the effects of mandatory IFRS adoption on the comparability of financial accounting information. Using two comparability proxies based on De Franco et al. [2011] and a comparability proxy based on the degree of information transfer, our results suggest that the overall comparability effect of mandatory IFRS adoption is marginal. We hypothesize that firm-level heterogeneity in IFRS compliance explains the limited comparability effect. To test this conjecture, we first hand-colle...

  7. Human papillomavirus testing as a cytology gold standard : comparing Surinam with the Netherlands

    NARCIS (Netherlands)

    Wachtel, MS; Boon, ME; Korporaal, H; Kok, LP

    Polymerase chain reaction to detect high- risk human papillomavirus has been suggested as a gold standard for cytology. The Netherlands and Surinam were prospectively compared in regard to the proportions of Negative, Atypical Squamous Cells of Undetermined Significance, and Squamous Intraepithelial

  8. Comparative costs of the Mouse Inoculation Test (MIT) and Virus Isolation in Cell Culture (VICC) for use in rabies diagnosis in Brazil.

    Science.gov (United States)

    Bones, Vanessa C; Gameiro, Augusto H; Castilho, Juliana G; Molento, Carla F M

    2015-05-01

    The decision to use laboratory animals rather than in vitro methods is frequently based on the financial costs involved, so the objective of our study was to compare the costs of performing the Mouse Inoculation Test (MIT) and Virus Isolation in Cell Culture (VICC) for use in rabies diagnosis in Brazil. Based on observations of laboratory routines at the Pasteur Institute, São Paulo, we listed the fixed cost (FC) and variable cost (VC) items necessary to perform both tests. Considering that 200 MITs are equivalent to 350 VICC assays, in terms of facilities and staff-hours needed per month, we calculated, for both tests, the average total cost per sample, the costs of the implementation of the laboratory structure, and the costs of routine use. With regard to absolute values, the total cost was mainly influenced by FC items, as they represented 60% of the cost for the MIT and 86% of the cost for VICC. A sample analysed by the MIT costs around 205% more than one analysed by using VICC. The MIT costs 74% and 406% more than VICC, when implementation costs and routine use per month, respectively, are taken into account. Our results can assist in the resolution of costing disputes that could hinder the replacement of animals for rabies diagnosis in Brazil. The method demonstrated here might also be useful for cost comparisons in other situations where animal use still continues when validated alternatives exist. 2015 FRAME.

  9. Comparative Validation of Building Simulation Software

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    The scope of this subtask is to perform a comparative validation of the building simulation software for the buildings with the double skin façade. The outline of the results in the comparative validation identifies the areas where is no correspondence achieved, i.e. calculation of the air flow r...... is that the comparative validation can be regarded as the main argument to continue the validation of the building simulation software for the buildings with the double skin façade with the empirical validation test cases.......The scope of this subtask is to perform a comparative validation of the building simulation software for the buildings with the double skin façade. The outline of the results in the comparative validation identifies the areas where is no correspondence achieved, i.e. calculation of the air flow...

  10. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  11. Avoidance test with Eisenia fetida as indicator for the habitat function of soils. Results of a laboratory comparison test

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany); Achazi, R.; Warnecke, D. [Free Univ. of Berlin, Inst. for Biology, Berlin (Germany); Roembke, J. [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2003-07-01

    Intention, Goal, Scope, Background. The habitat function of soils is often assessed using the reproduction test with Eisenia fetida. As this test is rather labour-intensive, an alternative is needed which is less cost-intensive in terms of duration and workload, but gives reasonable results. The avoidance test with E. fetida is a suitable screening test meeting these criteria. However, before a novel test system can be generally recommended it has to be ensured that comparable results are acquired from different laboratories on the basis of the respective test guideline. Objective. The avoidance test with E. fetida was performed as laboratory comparison test. The results were compared with those of the earthworm acute and reproduction tests carried out with the same soils. Methods. The three tests were performed by three laboratories using eight contaminated soils and three control soils. The contaminated soils were mixed with the control soils to obtain different concentrations of the contamination. (orig.)

  12. Central Nevada Test Area Monitoring Report

    International Nuclear Information System (INIS)

    Brad Lyles; Jenny Chapman; John Healey; David Gillespie

    2006-01-01

    Water level measurements were performed and water samples collected from the Central Nevada Test Area model validation wells in September 2006. Hydraulic head measurements were compared to previous observations; the MV wells showed slight recovery from the drilling and testing operation in 2005. No radioisotopes exceeded limits set in the Corrective Action Decision Document/Corrective Action Plan, and no significant trends were observed when compared to previous analyses

  13. The Danish National Tests

    DEFF Research Database (Denmark)

    Beuchert, Louise Voldby; Nandrup, Anne Brink

    In 2010, the Danish National Tests were implemented in the public compulsory schools as a mean of evaluating the performance of the public school system. The extensive test program consists of ten mandatory tests in six subjects in grades 2 through 8. In this paper, we share our insights from wor...... characteristics as well as pupils' 9th grade examination marks. We document a stable test score gap across grade levels and socio economic background and discuss the prospects of the national test data for future research....... within each test and argue that this is often a more feasible measure for data analyses compared to the transformed test score presented to pupils and teachers. We provide the reader with preliminary analyses of the relation between pupils' national test results and a wide range of pupil background...

  14. Comparison of the Reading Subtests of the Wechsler Individual Achievement Test-Third Edition and the Peabody Individual Achievement Test-Revised/Normative Update

    Science.gov (United States)

    Ott, Lauren M.

    2010-01-01

    This study compared the reading subtests of the Wechsler Individual Achievement Test-Third Edition and the Peabody Individual Achievement Test-Revised/Normative Update. Scores were compared on these two tests in a group of 28 students ages 7 through 12 who were referred or reevaluated for suspected learning problems. The data were collected…

  15. Cardiopulmonary Exercise Testing in Pediatrics

    NARCIS (Netherlands)

    Takken, Tim; Bongers, Bart C; van Brussel, Marco; Haapala, Eero A; Hulzebos, Erik Hj

    2017-01-01

    Aerobic fitness is an important determinant of overall health. Higher aerobic fitness has been associated with many health benefits. Because myocardial ischemia is rare in children, indications for exercise testing differ in children compared to adults. Pediatric exercise testing is imperative to

  16. The challenge of juvenile Huntington disease: to test or not to test.

    Science.gov (United States)

    Koutsis, Georgios; Karadima, Georgia; Kladi, Athina; Panas, Marios

    2013-03-12

    In a cohort of patients with suspected juvenile-onset Huntington disease (HD), we compared HD expansion-positive and -negative cases in order to identify parameters that may allow differentiating between them and may act as a guide to clinicians contemplating genetic testing. We analyzed the clinical and genetic characteristics of 76 juvenile-onset patients referred consecutively for HD genetic testing over a 16-year period. In total, 24 patients were positive for the HD expansion (7.8% of our HD cohort). Mean age at onset of expanded cases was similar to unexpanded cases. All expanded cases had a family history of genetically confirmed HD compared to only 13.5% of unexpanded cases (p = 0.000). Clinical symptoms at onset or at presentation could not differentiate between expanded and unexpanded patients. Although criteria suggested by previous reports allowed statistical differentiation between the 2 groups, they were not sufficiently sensitive and specific to be used in clinical context and performed less satisfactorily than presence of a family history of HD alone. A diagnosis of juvenile HD should be primarily contemplated in symptomatic children with a family history of HD, although a proportion of these will test negative. With no family history of HD, juvenile HD is very unlikely and genetic testing should never delay searching for other causes. The specific nature of symptoms at onset or at presentation is of limited value in guiding the decision to test or not to test.

  17. Decision Rules, Trees and Tests for Tables with Many-valued Decisions–comparative Study

    KAUST Repository

    Azad, Mohammad; Zielosko, Beata; Moshkov, Mikhail; Chikalov, Igor

    2013-01-01

    In this paper, we present three approaches for construction of decision rules for decision tables with many-valued decisions. We construct decision rules directly for rows of decision table, based on paths in decision tree, and based on attributes contained in a test (super-reduct). Experimental results for the data sets taken from UCI Machine Learning Repository, contain comparison of the maximum and the average length of rules for the mentioned approaches.

  18. Decision Rules, Trees and Tests for Tables with Many-valued Decisions–comparative Study

    KAUST Repository

    Azad, Mohammad

    2013-10-04

    In this paper, we present three approaches for construction of decision rules for decision tables with many-valued decisions. We construct decision rules directly for rows of decision table, based on paths in decision tree, and based on attributes contained in a test (super-reduct). Experimental results for the data sets taken from UCI Machine Learning Repository, contain comparison of the maximum and the average length of rules for the mentioned approaches.

  19. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    Science.gov (United States)

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  20. "Small intestinal biopsy and anti endomyosial sorologic test in children suspicious for celiac disease: a comparative study in Children Medical Center "

    Directory of Open Access Journals (Sweden)

    F. Mahjoub

    2006-08-01

    Full Text Available Background: Celiac is one the most common causes of malabsorption and is an autoimmune disorder resulting in damage to intestinal epithelial cells by self T lymphocytes. The main culprit is gluten. The aim of our study was to assess the histopathologic findings of patients suspicious to have celiac disease in their first admission and compare them with serologic findings (endomyosial antibody test: EMA. Methods: The study is a prospective descriptional type and 95 patients suspicious to have celiac disease were included who went under upper endoscopy and sampling and also serologic studies. Histopathologic findings were grouped by Marsh classification. Specimens in Marsh stage 0 and 1 were also stained for leukocyte common antigen by immunohistochemistry Results: Ninety five patients, 49 males and 46 females, ranging from 9 months to 17 years (mean: 6.3 ys were included in the study The most common complaint was abdominal pain. EMA test was positive in 43 patients. Most specimens were categorized as Marsh stage IIIA (51 cases by histopatholgic examination, which can be seen in many other conditions. Only 16 patients were categorized as Marsh stage IIIB & IIIC, which are seen in established celiac patients No significant correlation was found between histopathologic and serologic findings. No difference was found between H&E staining and immunohistochemical staining in counting of intra- epithelial lymphocytes. Conclusion: Most of our patients had mild partial villous atrophy which is also seen in many other disorders and also EMA test was negative in this group. It appears that current assessment of celiac disease has many drawbacks and necessity of more specific methods is highly appreciated.

  1. Correlations between power and test reactor data bases

    International Nuclear Information System (INIS)

    Guthrie, G.L.; Simonen, E.P.

    1989-02-01

    Differences between power reactor and test reactor data bases have been evaluated. Charpy shift data has been assembled from specimens irradiated in both high-flux test reactors and low-flux power reactors. Preliminary tests for the existence of a bias between test and power reactor data bases indicate a possible bias between the weld data bases. The bias is nonconservative for power predictive purposes, using test reactor data. The lesser shift for test reactor data compared to power reactor data is interpreted primarily in terms of greater point defect recombination for test reactor fluxes compared to power reactor fluxes. The possibility of greater thermal aging effects during lower damage rates is also discussed. 15 refs., 5 figs., 2 tabs

  2. Testing Hubbert

    International Nuclear Information System (INIS)

    Brandt, Adam R.

    2007-01-01

    The Hubbert theory of oil depletion, which states that oil production in large regions follows a bell-shaped curve over time, has been cited as a method to predict the future of global oil production. However, the assumptions of the Hubbert method have never been rigorously tested with a large, publicly available data set. In this paper, three assumptions of the modern Hubbert theory are tested using data from 139 oil producing regions. These regions are sub-national (United States state-level, United States regional-level), national, and multi-national (subcontinental and continental) in scale. We test the assumption that oil production follows a bell-shaped curve by generating best-fitting curves for each region using six models and comparing the quality of fit across models. We also test the assumptions that production over time in a region tends to be symmetric, and that production is more bell-shaped in larger regions than in smaller regions

  3. Motor proficiency in normal children and with learning difficulty: a comparative and correlational study based on the motor proficiency test of Bruininks-Oseretsky

    Directory of Open Access Journals (Sweden)

    Nilson Roberto Moreira

    2008-06-01

    Full Text Available The aim of this investigation is to verify the difference between children with learning disabilities and children without learning disabilities through motor proficiency test of Bruininks and Ozeretsky (1978. The sample was constituted by 30 children, with 8-year average age, 15 males and 15 females, subdivided into two groups of 15 children from both sexes: children without learning disabilities attending 3rd grade and children with learning disabilities attending 2nd grade having failed a term once. All of them came from a middle class background, according to Grafar scale (adapted by Fonseca, 1991. All children presenting any other disabilities were excluded from the sample. Intelligence factor “G” was controlled by using a percentile, higher or equal to 50 (middle and high level, measured by Raven’s (1974 progressive combinations test. In motor proficiency, children with learning disabilities showed significant differences when compared with normal children of the same age, in all components of global, composed and fine motricity. The tests administered showed a strong correlation between the variables of the motor proficiency components. The results lead to the conclusion that there were significant differences in motor proficiency between normal children and children with learning disabilities, who showed specific motor difficulties evincing a more vulnerable motor profile and not the presence of neurological dysfunction signs.

  4. Task specificity of finger dexterity tests

    NARCIS (Netherlands)

    Berger, M.A.M.; Krul, A.; Daanen, H.A.M.

    2009-01-01

    Finger dexterity tests are generally used to assess performance decrease due to gloves, cold and pathology. It is generally assumed that the O’Connor and Purdue Pegboard test yield similar results. In this experiment we compared these two tests for dry conditions without gloves, and for dry and wet

  5. Task specificity of finger dexterity tests

    NARCIS (Netherlands)

    Berger, M.A.M.; Krul, A.J.; Daanen, H.A.M.

    2009-01-01

    Finger dexterity tests are generally used to assess performance decrease due to gloves, cold and pathology. It is generally assumed that the O'Connor and Purdue Pegboard test yield similar results. In this experiment we compared these two tests for dry conditions without gloves, and for dry and wet

  6. The string-pulling paradigm in comparative psychology.

    Science.gov (United States)

    Jacobs, Ivo F; Osvath, Mathias

    2015-05-01

    String pulling is one of the most widely used paradigms in comparative psychology. First documented 2 millennia ago, it has been a well-established scientific paradigm for a century. More than 160 bird and mammal species have been tested in over 200 studies with countless methodological variations. The paradigm can be used to address a wide variety of issues on animal cognition; for example, what animals understand about contact and connection as well as whether they rely on perceptual feedback, grasp the functionality of strings, generalize across conditions, apply their knowledge flexibly, and possess insight. Mammals are typically tested on a horizontal configuration, birds on a vertical one, making the studies difficult to compare; in particular, pulling a string vertically requires better coordination and attention. A species' performance on the paradigm is often influenced by its ecology, especially concerning whether limbs are used for foraging. Many other factors can be of importance and should be considered. The string-pulling paradigm is easy to administer, vary, and apply to investigate a wide array of cognitive abilities. Although it can be and has been used to compare species, divergent methods and unclear reporting have limited its comparative utility. With increasing research standards, the paradigm is expected to become an even more fundamental tool in comparative psychology. (c) 2015 APA, all rights reserved).

  7. International comparative studies of education and large scale change

    NARCIS (Netherlands)

    Howie, Sarah; Plomp, T.; Bascia, Nina; Cumming, Alister; Datnow, Amanda; Leithwood, Kenneth; Livingstone, David

    2005-01-01

    The development of international comparative studies of educational achievements dates back to the early 1960s and was made possible by developments in sample survey methodology, group testing techniques, test development, and data analysis (Husén & Tuijnman, 1994, p. 6). The studies involve

  8. Avoiding Pitfalls in Molecular Genetic Testing: Case Studies of High-Resolution Array Comparative Genomic Hybridization Testing in the Definitive Diagnosis of Mowat-Wilson Syndrome

    OpenAIRE

    Kluk, Michael Joseph; An, Yu; James, Philip; Coulter, David; Harris, David; Wu, Bai-Lin; Shen, Yiping

    2011-01-01

    The molecular testing options available for the diagnosis of genetic disorders are numerous and include a variety of different assay platforms. The consultative input of molecular pathologists and cytogeneticists, working closely with the ordering clinicians, is often important for definitive diagnosis. Herein, we describe two patients who had long histories of unexplained signs and symptoms with a high clinical suspicion of an underlying genetic etiology. Initial molecular testing in both ca...

  9. Antirandom Testing: A Distance-Based Approach

    Directory of Open Access Journals (Sweden)

    Shen Hui Wu

    2008-01-01

    Full Text Available Random testing requires each test to be selected randomly regardless of the tests previously applied. This paper introduces the concept of antirandom testing where each test applied is chosen such that its total distance from all previous tests is maximum. This spans the test vector space to the maximum extent possible for a given number of vectors. An algorithm for generating antirandom tests is presented. Compared with traditional pseudorandom testing, antirandom testing is found to be very effective when a high-fault coverage needs to be achieved with a limited number of test vectors. The superiority of the new approach is even more significant for testing bridging faults.

  10. Small-bore-piping seismic-test findings

    International Nuclear Information System (INIS)

    Severud, L.K.; Barta, D.A.; Anderson, M.J.

    1981-12-01

    Description is given of a test series in which a 1-inch diameter stainless steel pipe system was subjected to dynamic testing. The test system consisted of approximately 40-feet of schedule 40 pipe, with several bends and risers, supported from a rigid test frame. FFTF prototypic pipe clamps, dead weight supports, mechanical snubbers, and insulation were utilized. Several variations of the pipe support configuration were tested. Measured test results are compared with analytical predictions for each configuration. Plans for future testing are discussed

  11. Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 2: Data from seat testing

    Science.gov (United States)

    Shane, S. J.

    1985-01-01

    The unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft is reviewed. A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is presented. An energy absorbing test seat is designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions is conducted at a sled test facility. Comparative tests with operational F-111 crewseats are also conducted. After successful dynamic testing of the seat, more testing is conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests are conducted. The vertical drop tests are used to obtain comparative data between the energy absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series. Volume 2 presents the data obtained during the seat test series, while Volume 3 presents the data from the crew module test series.

  12. A comparative study of monosaccharide composition analysis as a carbohydrate test for biopharmaceuticals.

    Science.gov (United States)

    Harazono, Akira; Kobayashi, Tetsu; Kawasaki, Nana; Itoh, Satsuki; Tada, Minoru; Hashii, Noritaka; Ishii, Akiko; Arato, Teruyo; Yanagihara, Shigehiro; Yagi, Yuki; Koga, Akiko; Tsuda, Yuriko; Kimura, Mikiko; Sakita, Masashi; Kitamura, Satoshi; Yamaguchi, Hideto; Mimura, Hisashi; Murata, Yoshimi; Hamazume, Yasuki; Sato, Takayuki; Natsuka, Shunji; Kakehi, Kazuaki; Kinoshita, Mitsuhiro; Watanabe, Sakie; Yamaguchi, Teruhide

    2011-05-01

    The various monosaccharide composition analysis methods were evaluated as monosaccharide test for glycoprotein-based pharmaceuticals. Neutral and amino sugars were released by hydrolysis with 4-7N trifluoroacetic acid. The monosaccharides were N-acetylated if necessary, and analyzed by high-performance liquid chromatography (HPLC) with fluorometric or UV detection after derivatization with 2-aminopyridine, ethyl 4-aminobenzoate, 2-aminobenzoic acid or 1-phenyl-3-methyl-5-pyrazolone, or high pH anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD). Sialic acids were released by mild acid hydrolysis or sialidase digestion, and analyzed by HPLC with fluorometric detection after derivatization with 1,2-diamino-4,5-methylenedioxybenzene, or HPAEC-PAD. These methods were verified for resolution, linearity, repeatability, and accuracy using a monosaccharide standard solution, a mixture of epoetin alfa and beta, and alteplase as models. It was confirmed that those methods were useful for ensuring the consistency of glycosylation. It is considered essential that the analytical conditions including desalting, selection of internal standards, release of monosaccharides, and gradient time course should be determined carefully to eliminate interference of sample matrix. Various HPLC-based monosaccharide analysis methods were evaluated as a carbohydrate test for glycoprotein pharmaceuticals by an inter-laboratory study. Copyright © 2011 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.

  13. Associations between mode of HIV testing and consent, confidentiality, and referral : a comparative analysis in four African countries

    OpenAIRE

    Obermeyer, C. M.; Neuman, M.; Desclaux, Alice; Wanyenze, R.; Ky-Zerbo, O.; Cherutich, P.; Namakhoma, I.; Hardon, A.

    2012-01-01

    Editors' Summary Background In 2007, World Health Organization (WHO) and the Joint United Nations Programme on HIV/AIDS (UNAIDS) issued a joint guidance document on “provider-initiated” HIV testing and counseling. They noted that previous testing strategies that relied on “client-initiated” testing (also referred to as VCT, for voluntary counseling and testing) had failed to reach enough people, both in high-income and resource-constrained countries—in Africa, for example, at that time, just ...

  14. Tests for nonlinearity in short stationary time series

    International Nuclear Information System (INIS)

    Chang, T.; Sauer, T.; Schiff, S.J.

    1995-01-01

    To compare direct tests for detecting determinism in chaotic time series, data from Henon, Lorenz, and Mackey--Glass equations were contaminated with various levels of additive colored noise. These data were analyzed with a variety of recently developed tests for determinism, and the results compared

  15. Implementation, Test Pattern Generation, and Comparative Analysis of Different Adder Circuits

    Directory of Open Access Journals (Sweden)

    Vikas K. Saini

    2016-01-01

    Full Text Available Addition usually affects the overall performance of digital systems and an arithmetic function. Adders are most widely used in applications like multipliers, DSP (i.e., FFT, FIR, and IIR. In digital adders, the speed of addition is constrained by the time required to propagate a carry through the adder. Various techniques have been proposed to design fast adders. We have derived architectures for carry-select adder (CSA, Common Boolean Logic (CBL based adders, ripple carry adder (RCA, and Carry Look-Ahead Adder (CLA for 8-, 16-, 32-, and 64-bit length. In this work we have done comparative analysis of different types of adders in Synopsis Design Compiler using different standard cell libraries at 32/28 nm. Also, the designs are analyzed for the stuck at faults (s-a-0, s-a-1 using Synopsis TetraMAX.

  16. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  17. A Comparative Analysis of the Rebound Hammer and Ultrasonic ...

    African Journals Online (AJOL)

    This work presents a study on the comparison between some non-destructive testing tech-niques (Rebound Hammer and Ultrasonic Pulse Velocity). Tests were performed to com-pare the accuracy between the rebound hammer and the ultrasonic pulse velocity methodin estimating the strength of concrete. Eighty samples ...

  18. Test Capability of Comparative NAA Method in Analysis of Long Lived Element in SRM 1648

    International Nuclear Information System (INIS)

    Sri-Wardani

    2005-01-01

    The comparative NAA method had been examine on the analysis of long-lived elements content in air particulate sample of NIST.SRM 1648 for evaluation of a capability of comparative NAA method that used at P2TRR. From the result of analysis it could be determined analysis elements contained in the sample, namely: Sc, Co, Zn, Br, Rb, Sb, Hf and Th with optimum results in bias of 10%. The optimum result of long-lived elements obtained on a good accuracy and precision. From the analysis data obtained showed that the comparative NAA method with Gamma Trac and APTEC software capable to analyze several kinds of elements in environmental samples. Therefore, this method could be implement in biological and healthy samples. (author)

  19. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 12189.

    Science.gov (United States)

    La Barbera, Luigi; Ottardi, Claudia; Villa, Tomaso

    2015-10-01

    compared with the previous model where the precompression was not considered. Neglecting the initial preload due to the assembly of the overall construct according to ISO 12189 standard could lead to an overestimation of the stress on the rods up to 50%. To correctly describe the state of stress on the posterior spinal fixator, tested according to the ISO procedure, it is important to take into account the initial preload due to the assembly of the overall construct. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Rare variant testing across methods and thresholds using the multi-kernel sequence kernel association test (MK-SKAT).

    Science.gov (United States)

    Urrutia, Eugene; Lee, Seunggeun; Maity, Arnab; Zhao, Ni; Shen, Judong; Li, Yun; Wu, Michael C

    Analysis of rare genetic variants has focused on region-based analysis wherein a subset of the variants within a genomic region is tested for association with a complex trait. Two important practical challenges have emerged. First, it is difficult to choose which test to use. Second, it is unclear which group of variants within a region should be tested. Both depend on the unknown true state of nature. Therefore, we develop the Multi-Kernel SKAT (MK-SKAT) which tests across a range of rare variant tests and groupings. Specifically, we demonstrate that several popular rare variant tests are special cases of the sequence kernel association test which compares pair-wise similarity in trait value to similarity in the rare variant genotypes between subjects as measured through a kernel function. Choosing a particular test is equivalent to choosing a kernel. Similarly, choosing which group of variants to test also reduces to choosing a kernel. Thus, MK-SKAT uses perturbation to test across a range of kernels. Simulations and real data analyses show that our framework controls type I error while maintaining high power across settings: MK-SKAT loses power when compared to the kernel for a particular scenario but has much greater power than poor choices.

  1. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    Science.gov (United States)

    Khng, Kiat Hui

    2017-11-01

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  2. Dispersant testing : a study on analytical test procedures

    International Nuclear Information System (INIS)

    Fingas, M.F.; Fieldhouse, B.; Wang, Z.; Environment Canada, Ottawa, ON

    2004-01-01

    Crude oil is a complex mixture of hydrocarbons, ranging from small, volatile compounds to very large, non-volatile compounds. Analysis of the dispersed oil is crucial. This paper described Environment Canada's ongoing studies on various traits of dispersants. In particular, it describes small studies related to dispersant effectiveness and methods to improve analytical procedures. The study also re-evaluated the analytical procedure for the Swirling Flask Test, which is now part of the ASTM standard procedure. There are new and improved methods for analyzing oil-in-water using gas chromatography (GC). The methods could be further enhanced by integrating the entire chromatogram rather than just peaks. This would result in a decrease in maximum variation from 5 per cent to about 2 per cent. For oil-dispersant studies, the surfactant-dispersed oil hydrocarbons consist of two parts: GC-resolved hydrocarbons and GC-unresolved hydrocarbons. This study also tested a second feature of the Swirling Flask Test in which the side spout was tested and compared with a new vessel with a septum port instead of a side spout. This decreased the variability as well as the energy and mixing in the vessel. Rather than being a variation of the Swirling Flask Test, it was suggested that a spoutless vessel might be considered as a completely separate test. 7 refs., 2 tabs., 4 figs

  3. Testing problem-solving capacities: differences between individual testing and social group setting.

    Science.gov (United States)

    Krasheninnikova, Anastasia; Schneider, Jutta M

    2014-09-01

    Testing animals individually in problem-solving tasks limits distractions of the subjects during the test, so that they can fully concentrate on the problem. However, such individual performance may not indicate the problem-solving capacity that is commonly employed in the wild when individuals are faced with a novel problem in their social groups, where the presence of a conspecific influences an individual's behaviour. To assess the validity of data gathered from parrots when tested individually, we compared the performance on patterned-string tasks among parrots tested singly and parrots tested in social context. We tested two captive groups of orange-winged amazons (Amazona amazonica) with several patterned-string tasks. Despite the differences in the testing environment (singly vs. social context), parrots from both groups performed similarly. However, we found that the willingness to participate in the tasks was significantly higher for the individuals tested in social context. The study provides further evidence for the crucial influence of social context on individual's response to a challenging situation such as a problem-solving test.

  4. Vocational Aptitude Test

    Directory of Open Access Journals (Sweden)

    Candiasa I Made

    2018-01-01

    Full Text Available Test for measuring vocational aptitude has been formulated and validated. There are three main constructs involved in vocational aptitude test, which are individual characteristics, activities that are likely to be selected, and professions that tend to be idolized. Individual characteristics indicate the individuals talents, whereas the activity that tends to be chosen leads to student interest in the activity, and the intended profession gives clues about the capability of themselves to pursue the profession. Content validity test with Lawse technique yields content validity ratio (CVR for all items are in the range 0.82-0.94 and content validity index (CVI = 0.88. The construct validity test yields comparative fit index (CFI = 0.918 and chi square coefficient (χ2 = 5.85 with significance (p = 0.002. These findings indicate that the test is valid either by content or construct. Furthermore, the reliability test with Alpha Cronbach found the alpha coefficient (α = 0.82. Finally, it can be concluded that vocational aptitude test can be utilized for early identification of student vocational aptitude. The hope, the test can help students to choose the appropriate vocational school, in order to obtain the better learning outcomes.

  5. Analyzing the determinants of willingness-to-pay values for testing the validity of the contingent valuation method. Application to home care compared to hospital care

    OpenAIRE

    Marie-Odile Carrère; Nathalie Havet; Magali Morelle; Raphaël Remonnay

    2008-01-01

    Working paper GATE 08-20; The contingent valuation (CV) method is an attractive approach for comparing home care to hospital care in which the only difference is patients' well-being during the treatment process and not health outcomes. We considered the empirical situation of blood transfusion (BT) in cancer patients and collected willingness to pay (WTP) values among BT users. Our main objective was to test the validity of the CV method, namely its ability to elicit true preferences. Firstl...

  6. Comparative anthelmintic activity investigation of selected ethno-medicinal weeds

    Science.gov (United States)

    Pueblos, Kirstin Rhys S.; Bajalla, Mark; Pacheco, Dixie; Ganot, Sheila; Paig, Daisy; Tapales, Radyn; Lagare, Jeanne; Quimque, Mark Tristan J.

    2017-01-01

    Helminth infections are one of the seriously neglected potent diseases in many parts of the world. The problems of parasitic helminthes becoming resistant to currently available anthelmintic drugs pose a challenge for the search - relying on natural products - for new and better anthelmintics. In this paper, four abundant Philippine weeds: Chrysopogon aciculatus Trin. Cyperus brevifolius Rottb., Ruellia tuberosa Linn. and Saccharum spontaneum Linn. were investigated for their anthelmintic activities to establish basis of their folkloric claim. The hexane-soluble and chloroform-soluble extracts were obtained through sequential solvent partitioning of the crude ethanolic extract of the air-dried aerial part of each plant sample. Meanwhile, the decoction was obtained from fresh aerial part of the plant samples. All extracts were then subjected to in vitro anthelmintic screening at different concentration as per method of Ghosh, et al. against African nightcrawler earthworms (Eudrillus euginiae) in which the activity of the extracts was determined by correlation with time. The anthelmintic bioassay results revealed a dose-dependent toxicity relationship. It indicated relatively low anthelmintic activities of the decoction of the four plant samples as compared to their corresponding crude ethanol extracts. Among the crude ethanol extracts, C. brevifolius (CBE) gave fastest time to bring about paralysis and death to the test organisms at all concentrations tested. For the hexane extracts, R. tuberosa (RTH) gave better activity among other plant samples. Lastly, among the chloroform-soluble extracts, both that of C. brevifolius (CBC) and R. tuberosa (RTC) comparably showed strongest anthelmintic activities at all tested concentrations, thus, exhibited best anthelmintic activity that is remarkably comparable to the positive control, Mebendazole at the highest concentration tested. In fact, CBC and RTC showed highest anthelmintic potential compared to all extracts tested in

  7. The Stockholm-3 (STHLM3) Model can Improve Prostate Cancer Diagnostics in Men Aged 50-69 yr Compared with Current Prostate Cancer Testing.

    Science.gov (United States)

    Eklund, Martin; Nordström, Tobias; Aly, Markus; Adolfsson, Jan; Wiklund, Peter; Brandberg, Yvonne; Thompson, James; Wiklund, Fredrik; Lindberg, Johan; Presti, Joseph C; StLezin, Mark; Clements, Mark; Egevad, Lars; Grönberg, Henrik

    2016-11-23

    Prostate cancer screening is associated with low specificity, unnecessary biopsies, and overdiagnosis. We have previously shown that the Stockholm-3 model (S3M) can reduce biopsies compared with using prostate-specific antigen (PSA) ≥3ng/ml as an indication for biopsy. Urologists in today's current prostate cancer testing (CPT) have access to numerous variables in addition to PSA (eg, age, ethnicity, family history, free PSA, PSA velocity, digital rectal examination, and prostate volume) to support biopsy decisions. We estimated the number of prostate cancers diagnosed and prostate biopsies performed if S3M replaced CPT in Stockholm, Sweden, by comparing biopsy results in 56 282 men who underwent PSA testing according to CPT in Stockholm in 2011 with the 47 688 men enrolled in the STHLM3 validation cohort 2012-2015. With the same sensitivity as CPT to diagnose Gleason score ≥7 prostate cancer, S3M was estimated to reduce the number of men biopsied by 53% (95% confidence interval [CI]: 41-65%), avoid 76% (95% CI: 67-81%) of negative biopsies, and reduce Gleason score 6 cancers by 23% (95% CI: 6-40%). S3M has the potential to improve prostate cancer diagnostics by better selecting men with high risk of GS ≥7 prostate cancer. We modeled the effect the Stockholm-3 model would have on prostate cancer diagnostics if it replaced current clinical practice. We found that Stockholm-3 model may substantially reduce the number of biopsies, while maintaining the same sensitivity to diagnose clinically significant prostate cancer. Copyright © 2016. Published by Elsevier B.V.

  8. Hydraulic testing in crystalline rock

    International Nuclear Information System (INIS)

    Almen, K.E.; Andersson, J.E.; Carlsson, L.; Hansson, K.; Larsson, N.A.

    1986-12-01

    Swedish Geolocical Company (SGAB) conducted and carried out single-hole hydraulic testing in borehole Fi 6 in the Finnsjoen area of central Sweden. The purpose was to make a comprehensive evaluation of different methods applicable in crystalline rocks and to recommend methods for use in current and scheduled investigations in a range of low hydraulic conductivity rocks. A total of eight different methods of testing were compared using the same equipment. This equipment was thoroughly tested as regards the elasticity of the packers and change in volume of the test section. The use of a hydraulically operated down-hole valve enabled all the tests to be conducted. Twelve different 3-m long sections were tested. The hydraulic conductivity calculated ranged from about 5x10 -14 m/s to 1x10 -6 m/s. The methods used were water injection under constant head and then at a constant rate-of-flow, each of which was followed by a pressure fall-off period. Water loss, pressure pulse, slug and drill stem tests were also performed. Interpretation was carried out using standard transient evaluation methods for flow in porous media. The methods used showed themselves to be best suited to specific conductivity ranges. Among the less time-consuming methods, water loss, slug and drill stem tests usually gave somewhat higher hydraulic conductivity values but still comparable to those obtained using the more time-consuming tests. These latter tests, however, provided supplementary information on hydraulic and physical properties and flow conditions, together with hydraulic conductivity values representing a larger volume of rock. (orig./HP)

  9. A Chemistry Concept Reasoning Test

    Science.gov (United States)

    Cloonan, Carrie A.; Hutchinson, John S.

    2011-01-01

    A Chemistry Concept Reasoning Test was created and validated providing an easy-to-use tool for measuring conceptual understanding and critical scientific thinking of general chemistry models and theories. The test is designed to measure concept understanding comparable to that found in free-response questions requiring explanations over…

  10. An evaluation of clinical performance of FTA cards for HPV 16/18 detection using cobas 4800 HPV Test compared to dry swab and liquid medium.

    Science.gov (United States)

    Dong, Li; Lin, Chunqing; Li, Li; Wang, Margaret; Cui, Jianfeng; Feng, Ruimei; Liu, Bin; Wu, Zeni; Lian, Jia; Liao, Guangdong; Chen, Wen; Qiao, Youlin

    2017-09-01

    Effective dry storage and transport media as an alternative to conventional liquid-based medium would facilitate the accessibility of women in the low-resource settings to human papillomavirus (HPV)- based cervical cancer screening. To evaluate analytical and clinical performance of indicating FTA™ Elute Cartridge (FTA card) for the detection of HPV16/18 and cervical precancerous lesions and cancer compared to dry swab and liquid medium. Ninety patients with abnormal cytology and/or HPV infection were included for analysis. Three specimens of cervical exfoliated cells from each woman were randomly collected by FTA card, dry swab or liquid-based medium prior to colposcopy examination. The subsequent HPV DNA tests were performed on cobas 4800 HPV platform. High-risk HPV (hrHPV) positivity rate was 63.3%, 62.2% and 65.6% for samples collected by FTA card, dry swab and liquid medium, respectively. The overall agreements and kappa values for the detection of hrHPV, HPV 16 and HPV 18 between FTA card and liquid-based medium were 88.9% (κ=0.76), 97.8% (κ=0.94) and 100% (κ=1.0),respectively; between FTA card and dry swab were 92.1% (κ=0.83), 94.5% (κ=0.87) and 100% (κ=1.0), respectively. The performances of hrHPV tested by FTA card, dry swab, and liquid-based medium for detecting CIN2+ were comparable in terms of the sensitivity and specificity. The specificity of detection of CIN2+ by HPV16/18 increased by approximately 40% compared to hrHPV for any medium albeit at cost of a moderate loss of sensitivity. Dry medium might offer an alternative to conventional liquid-based medium in the HPV-based cervical cancer screening program especially in low-resource settings but still needs further evaluation. Copyright © 2017. Published by Elsevier B.V.

  11. Comparative analysis of minor histocompatibility antigens genotyping methods

    Directory of Open Access Journals (Sweden)

    A. S. Vdovin

    2016-01-01

    Full Text Available The wide range of techniques could be employed to find mismatches in minor histocompatibility antigens between transplant recipients and their donors. In the current study we compared three genotyping methods based on polymerase chain reaction (PCR for four minor antigens. Three of the tested methods: allele-specific PCR, restriction fragment length polymorphism and real-time PCR with TaqMan probes demonstrated 100% reliability when compared to Sanger sequencing for all of the studied polymorphisms. High resolution melting analysis was unsuitable for genotyping of one of the tested minor antigens (HA-1 as it has linked synonymous polymorphism. Obtained data could be used to select the strategy for large-scale clinical genotyping.

  12. A Comparative Study on the Formation Mechanism of Wear Scars during the Partial and Full Scale Fretting Wear Tests of Spacer Grids

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Ho; Shin, Chang Hwan; Oh, Dong Seok; Kang, Heung Seok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    traces without considering flow field effects. So, in this study, fretting wear tests of nuclear fuel rod with partial and full scale spacer girds have been performed to compare the morphology of wear scars at each test condition and to verify the flow field effect on the variation of fretting wear mechanism

  13. A Comparative Study on the Formation Mechanism of Wear Scars during the Partial and Full Scale Fretting Wear Tests of Spacer Grids

    International Nuclear Information System (INIS)

    Lee, Young Ho; Shin, Chang Hwan; Oh, Dong Seok; Kang, Heung Seok

    2012-01-01

    traces without considering flow field effects. So, in this study, fretting wear tests of nuclear fuel rod with partial and full scale spacer girds have been performed to compare the morphology of wear scars at each test condition and to verify the flow field effect on the variation of fretting wear mechanism

  14. Global Envelope Tests for Spatial Processes

    DEFF Research Database (Denmark)

    Myllymäki, Mari; Mrkvička, Tomáš; Grabarnik, Pavel

    2017-01-01

    Envelope tests are a popular tool in spatial statistics, where they are used in goodness-of-fit testing. These tests graphically compare an empirical function T(r) with its simulated counterparts from the null model. However, the type I error probability α is conventionally controlled for a fixed d......) the construction of envelopes for a deviation test. These new tests allow the a priori selection of the global α and they yield p-values. We illustrate these tests using simulated and real point pattern data....

  15. Global envelope tests for spatial processes

    DEFF Research Database (Denmark)

    Myllymäki, Mari; Mrkvička, Tomáš; Grabarnik, Pavel

    Envelope tests are a popular tool in spatial statistics, where they are used in goodness-of-fit testing. These tests graphically compare an empirical function T(r) with its simulated counterparts from the null model. However, the type I error probability α is conventionally controlled for a fixed......) the construction of envelopes for a deviation test. These new tests allow the a priori selection of the global α and they yield p-values. We illustrate these tests using simulated and real point pattern data....

  16. Comparing ELISA test-positive prevalence, risk factors and management recommendations for Johne's disease prevention between organic and conventional dairy farms in Ontario, Canada.

    Science.gov (United States)

    Pieper, Laura; Sorge, Ulrike S; DeVries, Trevor; Godkin, Ann; Lissemore, Kerry; Kelton, David

    2015-11-01

    Johne's disease (JD) is a chronic, infectious disease in cattle. Between 2010 and 2013, a voluntary JD control program was successfully launched in Ontario, Canada, including a Risk Assessment and Management Plan (RAMP) and JD ELISA testing of the entire milking herd. Over the last decade, the organic dairy sector has been growing. However, organic farming regulations and philosophies may influence the risk for JD transmission on Ontario organic dairy farms. The aim of this cross-sectional study was to investigate differences in JD ELISA test positive prevalence, risk factors for JD and recommendations for JD prevention between organic and conventional dairy herds in Ontario. RAMP results (i.e. RAMP scores and recommendations) and ELISA results were available for 2103 dairy herds, including 42 organic herds. If available, additional data on milk production, milk quality, and herd characteristics were gathered. Organic and conventional herds had a similar herd-level JD ELISA test-positive prevalence (26.2% and 27.2%, respectively). Organic herds (4.2%) had a higher within-herd JD ELISA test-positive prevalence compared to conventional herds (2.3%) if they had at least one JD test-positive animal on the farm. Organic farms had lower risk scores for biosecurity (9 points lower), and higher scores in the calving (7 points higher) and the calf-rearing management areas (4 points higher). After accounting for RAMP score, organic farms received fewer recommendations for the calving management area (Odds Ratio=0.41) and more recommendations in the adult cow management area (Odds Ratio=2.70). A zero-inflated negative binomial model was built with purchase of animals and the herd size included in the logistic portion of the model. Herd type (organic or conventional), colostrum and milk feeding practices, average bulk tank somatic cell count, and presence of non-Holstein breeds were included in the negative binomial portion of the model. Organic farms had a higher number of

  17. Summary of HEDL sodium fire tests

    International Nuclear Information System (INIS)

    Hillard, R.K.

    1978-10-01

    The sodium fire test program and related studies at the Hanford Engineering Development Laboratory (HEDL) are described. The program is analytical and experimental in scope, with computer code development and experimental verification. Tests have ranged in size from gram quantity laboratory tests to 1600-kg sodium spills. The experimental work is performed in two facilities: the Large Sodium Fire Facility (LSFF) and the Containment Systems Test Facility (CSTF). Sodium fire extinguishment tests which verified the Fast Flux Test Facility (FFTF) secondary sodium fire protection system are described and related informaion on sodium burning rates and smoke release rates are correlated. The burning rates are compared to theoretical predictions based on heat and mass transfer analogy, with good agreement. Comparisons with the SOFIRE-II code are also made. Sodium combustion aerosol properties are defined as to chemical and physical nature, settling in closed vessels and effect of added water vapor. The HAA-3B aerosol behavior computer code is compared to tests in the 850-m 3 CSTF containment vessel. Sodium spray tests in the CSTF are compared with the SPRAY computer code. An air cleaning program is described, which has the objective of removing high mass concentration sodium combustion aerosols from vented cells and containment buildings. The aerosol mass holding capacity of commercial filters was measured and an aqueous scrubber system is described. The effects of sodium spills on cell structures were investigated, including water release from heated concrete, the reaction of sodium with concrete, the formation and spontaneous recombination of hydrogen, and the ability of steel cell liners to withstand large spills of high temperature sodium without leaking

  18. Estimation of the level of anxiety in rats: differences in results of open-field test, elevated plus-maze test, and Vogel's conflict test.

    Science.gov (United States)

    Sudakov, S K; Nazarova, G A; Alekseeva, E V; Bashkatova, V G

    2013-07-01

    We compared individual anxiety assessed by three standard tests, open-field test, elevated plus-maze test, and Vogel conflict drinking test, in the same animals. No significant correlations between the main anxiety parameters were found in these three experimental models. Groups of animals with high and low anxiety rats were formed by a single parameter and subsequent selection of two extreme groups (10%). It was found that none of the tests could be used for reliable estimation of individual anxiety in rats. The individual anxiety level with high degree of confidence was determined in high-anxiety and low-anxiety rats demonstrating behavioral parameters above and below the mean values in all tests used. Therefore, several tests should be used for evaluation of the individual anxiety or sensitivity to emotional stress.

  19. Standardising the lactulose mannitol test of gut permeability to minimise error and promote comparability.

    Directory of Open Access Journals (Sweden)

    Ivana R Sequeira

    Full Text Available BACKGROUND: Lactulose mannitol ratio tests are clinically useful for assessing disorders characterised by changes in gut permeability and for assessing mixing in the intestinal lumen. Variations between currently used test protocols preclude meaningful comparisons between studies. We determined the optimal sampling period and related this to intestinal residence. METHODS: Half-hourly lactulose and mannitol urinary excretions were determined over 6 hours in 40 healthy female volunteers after administration of either 600 mg aspirin or placebo, in randomised order at weekly intervals. Gastric and small intestinal transit times were assessed by the SmartPill in 6 subjects from the same population. Half-hourly percentage recoveries of lactulose and mannitol were grouped on a basis of compartment transit time. The rate of increase or decrease of each sugar within each group was explored by simple linear regression to assess the optimal period of sampling. KEY RESULTS: The between subject standard errors for each half-hourly lactulose and mannitol excretion were lowest, the correlation of the quantity of each sugar excreted with time was optimal and the difference between the two sugars in this temporal relationship maximal during the period from 2½-4 h after ingestion. Half-hourly lactulose excretions were generally increased after dosage with aspirin whilst those of mannitol were unchanged as was the temporal pattern and period of lowest between subject standard error for both sugars. CONCLUSION: The results indicate that between subject variation in the percentage excretion of the two sugars would be minimised and the differences in the temporal patterns of excretion would be maximised if the period of collection of urine used in clinical tests of small intestinal permeability were restricted to 2½-4 h post dosage. This period corresponds to a period when the column of digesta column containing the probes is passing from the small to the large

  20. Generating an Automated Test Suite by Variable Strength Combinatorial Testing for Web Services

    Directory of Open Access Journals (Sweden)

    Yin Li

    2016-09-01

    Full Text Available Testing Web Services has become the spotlight of software engineering as an important means to assure the quality of Web application. Due to lacking of graphic interface and source code, Web services need an automated testing method, which is an important part in efficiently designing and generating test suite. However, the existing testing methods may lead to the redundancy of test suite and the decrease of fault-detecting ability since it cannot handle scenarios where the strengths of the different interactions are not uniform. With the purpose of solving this problem, firstly the formal tree model based on WSDL is constructed and the actual interaction relationship of each node is made sufficient consideration into, then the combinatorial testing is proposed to generate variable strength combinatorial test suite based on One-test-at-a-time strategy. At last test cases are minimized according to constraint rules. The results show that compared with conventional random testing, the proposed approach can detect more errors with the same amount of test cases which turning out to be more ideal than existing ones in size.

  1. A comparative study of an elisa test and an indirect immunofluorescence test for serological diagnosis of Babesia bovis infection

    International Nuclear Information System (INIS)

    Martins, J.R.; Cheong, F.H.; Correa, B.L.; Radley, D.E.; Cereser, V.H.

    1998-01-01

    Detection of antibodies to Babesia bovis in cattle is essential for the understanding of the epidemiology of babesiosis and this study was concerned with comparing the indirect fluorescent antibody with the ELISA. Both assays gave rise to 100% sensitivity whilst the ELISA was shown to be marginally more specific at 98%. The ease of use and low cost of the ELISA would make it the more obvious choice in conducting future serological surveys for this parasite. (author)

  2. Ethnic Comparisons in HIV Testing Attitudes, HIV Testing, and Predictors of HIV Testing Among Black and White College Students.

    Science.gov (United States)

    Moore, Melanie P; Javier, Sarah J; Abrams, Jasmine A; McGann, Amanda Wattenmaker; Belgrave, Faye Z

    2017-08-01

    This study's primary aim was to examine ethnic differences in predictors of HIV testing among Black and White college students. We also examined ethnic differences in sexual risk behaviors and attitudes toward the importance of HIV testing. An analytic sample of 126 Black and 617 White undergraduatestudents aged 18-24 were analyzed for a subset of responses on the American College Health Association-National College Health Assessment II (ACHA-NCHA II) (2012) pertaining to HIV testing, attitudes about the importance of HIV testing, and sexual risk behaviors. Predictors of HIV testing behavior were analyzed using logistic regression. t tests and chi-square tests were performed to access differences in HIV test history, testing attitudes, and sexual risk behaviors. Black students had more positive attitudes toward testing and were more likely to have been tested for HIV compared to White students. A greater number of sexual partners and more positive HIV testing attitudes were significant predictors of HIV testing among White students, whereas relationship status predicted testing among Black students. Older age and history of ever having sex were significant predictors of HIV testing for both groups. There were no significant differences between groups in number of sexual partners or self-reports in history of sexual experience (oral, vaginal, or anal). Factors that influence HIV testing may differ across racial/ethnic groups. Findings support the need to consider racial/ethnic differences in predictors of HIV testing during the development and tailoring of HIV testing prevention initiatives targeting college students.

  3. Comparative Intradermal Tuberculin Testing of Free-Ranging African Buffaloes (Syncerus caffer Captured for Ex Situ Conservation in the Kafue Basin Ecosystem in Zambia

    Directory of Open Access Journals (Sweden)

    Hetron Mweemba Munang'andu

    2011-01-01

    Full Text Available Bovine tuberculosis (BTB is endemic in African buffaloes (Syncerus caffer in some National Parks in Southern Africa, whilst no studies have been conducted on BTB on buffalo populations in Zambia. The increased demand for ecotourism and conservation of the African buffalo on private owned game ranches has prompted the Zambian Wildlife Authority (ZAWA and private sector in Zambia to generate a herd of “BTB-free buffaloes” for ex situ conservation. In the present study, 86 African buffaloes from four different herds comprising a total of 530 animals were investigated for the presence of BTB for the purpose of generating “BTB free” buffalo for ex-situ conservation. Using the comparative intradermal tuberculin test (CIDT the BTB status at both individual animal and herd level was estimated to be 0.0% by the CIDT technique. Compared to Avian reactors only, a prevalence of 5.8% was determined whilst for Bovine-only reactors a prevalence of 0.0% was determined. These results suggest the likelihood of buffalo herds in the Kafue National Park being free of BTB.

  4. Comparative analysis of the 1-mile run test evaluation formulae: assessment of aerobic capacity in male law enforcement officers aged 20-23 years.

    Science.gov (United States)

    Kayihan, Gürhan; Özkan, Ali; Köklü, Yusuf; Eyuboğlu, Ender; Akça, Firat; Koz, Mitat; Ersöz, Gülfem

    2014-04-01

    The purpose of this study was to compare values of aerobic performance in the 1-mile run test (1-MRT) using different formulae. Aerobic capacities of 351 male volunteers working for the Turkish National Police within the age range of 20-23 years were evaluated by the 1-MRT and the 20-metre shuttle run (20-MST). VO2max values were estimated by the prediction equations developed by George et al. (1993), Cureton et al. (1995) and Kline et al. (1987) for the 1-MRT and by Leger and Lambert (1982) for the 20-MST. The difference between the results of the different formulae was significant (p = 0.000). The correlation coefficient between the estimated VO2max using Cureton's equation, George's equation, Kline's equation and the 20-MST were 0.691 (p compares the use of 3 different formulae to estimate VO2max from 1-mile run/walk performance in male law enforcement officers aged 20-23 years for the first time and reports the most accurate formula to use when evaluating aerobic capacities of large numbers of healthy individuals.

  5. Testing of abrasion materials

    International Nuclear Information System (INIS)

    Hummert, G.

    1983-01-01

    A method of abrasion testing according to ASTM C 704-76 a is presented for steel fibre concrete mortar, fusion-cast basalt and a surface coating material and results of practical interest are mentioned. Due to the high technical demands on these materials and their specific fields of application, the very first test already supplied interesting findings. From the user's point of view, the method is an interesting alternative to the common test methods, e.g. according to DIN 52 108 (wheel test according to Boehme). In English-speaking countries, testing according to ASTM is often mandatory in the refractory industry in order to assure constant quality of refractory materials after setting. The method is characterized by good comparability and high accuracy of measurement. Only the test piece is exchanged while the test conditions remain constant, so that accurate information on the material studied is obtained. (orig.) [de

  6. PERFORMANCE OF STEEL FIBER REINFORCED CONCRETE – COMPARABILITY OF TESTS ACCORDING TO DAFSTB-GUIDELINE "STAHLFASERBETON" AND EN 14651

    Directory of Open Access Journals (Sweden)

    Steffen Anders

    2016-12-01

    Full Text Available For the determination of the performance of steel-fiber reinforced concrete (SFRC, the post-peak flexural strengths are used. In different national and European standards, different test-setups are defined, resulting in double efforts for testing for the manufacturers. In addition, the German national guideline "Stahlfaserbeton (DAfStb" on SFRC is well established European-wide, but the test standard is specifically national, demanding a four-point-bending tests using unnotched beams. Contrarily, the European standard EN 14651 as well as the Model Code 2010 demand three-point bending tests using notched specimens. Applying the national guideline is obligatory in Germany for structural use of SFRC. Therefore, it is essential to standardize the performance evaluation of SFRC based on commonly applied international guidelines. In the following, an approach is presented especially dealing with the problem of random occurrence of cracks in the four-point-bending tests. It is shown, that neglecting the point of crack can systematically under-estimate the performance of SFRC especially at deformations.

  7. Individual differences and subjective workload assessment - Comparing pilots to nonpilots

    Science.gov (United States)

    Vidulich, Michael A.; Pandit, Parimal

    1987-01-01

    Results by two groups of subjects, pilots and nonpilots, for two subjective workload assessment techniques (the SWAT and NASA-TLX tests) intended to evaluate individual differences in the perception and reporting of subjective workload are compared with results obtained for several traditional personality tests. The personality tests were found to discriminate between the groups while the workload tests did not. It is concluded that although the workload tests may provide useful information with respect to the interaction between tasks and personality, they are not effective as pure tests of individual differences.

  8. HIV testing in dermatology - a national audit.

    Science.gov (United States)

    Esson, Gavin A; Holme, S A

    2018-05-01

    Forty percent of individuals have late-stage HIV at the time of diagnosis, resulting in increased morbidity. Identifying key diseases which may indicate HIV infection can prompt clinicians to trigger testing, which may result in more timely diagnosis. The British HIV Association has published guidelines on such indicator diseases in dermatology. We audited the practice of HIV testing in UK dermatologists and General Practitioners (GPs) and compared results with the national guidelines. This audit showed that HIV testing in key indicator diseases remains below the standard set out by the national guidelines, and that GPs with special interest in dermatology have a lower likelihood for testing, and lower confidence when compared to consultants, registrars and associate specialists. Large proportions of respondents believed further training in HIV testing would be beneficial.

  9. Expectancy of an open-book test decreases performance on a delayed closed-book test.

    Science.gov (United States)

    Agarwal, Pooja K; Roediger, Henry L

    2011-11-01

    Two experiments examined the influence of practice with, and the expectancy of, open-book tests (students viewed studied material while taking the test) versus closed-book tests (students completed the test without viewing the studied material) on delayed retention and transfer. Using GRE materials specifically designed for open-book testing, participants studied passages and then took initial open- or closed-book tests. Open-book testing led to better initial performance than closed-book testing, but on a delayed criterial (closed-book) test both types of testing produced similar retention after a two-day delay in Experiment 1. In Experiment 2 participants were informed in advance about the type of delayed criterial test to expect (open- or closed-book). Expecting an open-book test (relative to a closed-book test) decreased participants' time spent studying and their delayed test performance on closed-book comprehension and transfer tests, demonstrating that test expectancy can influence long-term learning. Expectancy of open-book tests may impair long-term retention and transfer compared to closed-book tests, despite superior initial performance on open-book tests and students' preference for open-book tests.

  10. The 1-Minute Sit-to-Stand Test in Adults With Cystic Fibrosis: Correlations With Cardiopulmonary Exercise Test, 6-Minute Walk Test, and Quadriceps Strength.

    Science.gov (United States)

    Gruet, Mathieu; Peyré-Tartaruga, Leonardo Alexandre; Mely, Laurent; Vallier, Jean-Marc

    2016-12-01

    Exercise testing is part of the regular assessment of patients with cystic fibrosis (CF). We aimed to evaluate (1) the convergent validity of the 1-min sit-to-stand (STS) test in CF by investigating its relationships with peak oxygen uptake (peak V̇ O 2 ), quadriceps strength, and quality of life and (2) to compare these associations with those of the 6-min walk test (6MWT). Twenty-five adults with CF (FEV 1 = 59 ± 24%) performed the STS test, the 6MWT, quadriceps strength assessment, and cardiopulmonary exercise test (CPET). Physical activity level, quality of life, and self-esteem were assessed by questionnaires. STS repetitions, 6-min walk distance, quadriceps strength, and peak V̇ O 2 were, respectively, 71 ± 12, 90 ± 10, 93 ± 29, and 62 ± 16% of predicted. The STS test had moderate associations with peak V̇ O 2 (r = 0.56, P = .004), quadriceps strength (r = 0.52, P = .008), and some questionnaire items (eg, perceived physical strength, r = 0.67, P test was strongly associated with oxygen desaturation during CPET (r = 0.80, P test as compared with CPET (P test cannot be used as a replacement for CPET to accurately assess peak exercise capacity in CF. The STS test may have utility in detecting patients with CF who may exhibit a high level of oxygen desaturation during heavy exercise. Further studies should identify the factors contributing to STS performance to confirm the potential interest of STS repetitions × body weight outcome as a useful submaximal exercise parameter in CF. Copyright © 2016 by Daedalus Enterprises.

  11. The new INRIM rotating encoder angle comparator (REAC)

    International Nuclear Information System (INIS)

    Pisani, Marco; Astrua, Milena

    2017-01-01

    A novel angle comparator has been built and tested at INRIM. The device is based on a double air bearing structure embedding a continuously rotating encoder, which is read by two heads: one fixed to the base of the comparator and a second fixed to the upper moving part of the comparator. The phase measurement between the two heads’ signals is proportional to the relative angle suspended between them (and, therefore, the angle between the base and the upper, movable part of the comparator). The advantage of this solution is to reduce the encoder graduation errors and to cancel the cyclic errors due to the interpolation of the encoder lines. By using only two pairs of reading heads, we have achieved an intrinsic accuracy of  ±0.04″ (rectangular distribution) that can be reduced through self-calibration. The residual cyclic errors have shown to be less than 0.01″ peak-to-peak. The random fluctuations are less than 0.01″ rms on a 100 s time interval. A further advantage of the rotating encoder is the intrinsic knowledge of the absolute position without the need of a zeroing procedure. Construction details of the rotating encoder angle comparator (REAC), characterization tests, and examples of practical use are given. (paper)

  12. Comparative study between EDXRF and ASTM E572 methods using two-way ANOVA

    Science.gov (United States)

    Krummenauer, A.; Veit, H. M.; Zoppas-Ferreira, J.

    2018-03-01

    Comparison with reference method is one of the necessary requirements for the validation of non-standard methods. This comparison was made using the experiment planning technique with two-way ANOVA. In ANOVA, the results obtained using the EDXRF method, to be validated, were compared with the results obtained using the ASTM E572-13 standard test method. Fisher's tests (F-test) were used to comparative study between of the elements: molybdenum, niobium, copper, nickel, manganese, chromium and vanadium. All F-tests of the elements indicate that the null hypothesis (Ho) has not been rejected. As a result, there is no significant difference between the methods compared. Therefore, according to this study, it is concluded that the EDXRF method was approved in this method comparison requirement.

  13. Comparing Different Fault Identification Algorithms in Distributed Power System

    Science.gov (United States)

    Alkaabi, Salim

    A power system is a huge complex system that delivers the electrical power from the generation units to the consumers. As the demand for electrical power increases, distributed power generation was introduced to the power system. Faults may occur in the power system at any time in different locations. These faults cause a huge damage to the system as they might lead to full failure of the power system. Using distributed generation in the power system made it even harder to identify the location of the faults in the system. The main objective of this work is to test the different fault location identification algorithms while tested on a power system with the different amount of power injected using distributed generators. As faults may lead the system to full failure, this is an important area for research. In this thesis different fault location identification algorithms have been tested and compared while the different amount of power is injected from distributed generators. The algorithms were tested on IEEE 34 node test feeder using MATLAB and the results were compared to find when these algorithms might fail and the reliability of these methods.

  14. Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 3: Data from crew module testing

    Science.gov (United States)

    Shane, S. J.

    1985-01-01

    Over the past years, several papers and reports have documented the unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft. This report documents a program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats. An energy absorbing test seat was designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions, was conducted at a sled test facility. Comparative tests with operational F-111 crewseats were also conducted. After successful dynamic testing of the seat, more testing was conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests werre conducted. The vertical drop tests were used to obtain comparative data between the energy absorbing and operational seats.

  15. Testing Testing Testing.

    Science.gov (United States)

    Deville, Craig; O'Neill, Thomas; Wright, Benjamin D.; Woodcock, Richard W.; Munoz-Sandoval, Ana; Gershon, Richard C.; Bergstrom, Betty

    1998-01-01

    Articles in this special section consider (1) flow in test taking (Craig Deville); (2) testwiseness (Thomas O'Neill); (3) test length (Benjamin Wright); (4) cross-language test equating (Richard W. Woodcock and Ana Munoz-Sandoval); (5) computer-assisted testing and testwiseness (Richard Gershon and Betty Bergstrom); and (6) Web-enhanced testing…

  16. Comparing two Poisson populations sequentially: an application

    International Nuclear Information System (INIS)

    Halteman, E.J.

    1986-01-01

    Rocky Flats Plant in Golden, Colorado monitors each of its employees for radiation exposure. Excess exposure is detected by comparing the means of two Poisson populations. A sequential probability ratio test (SPRT) is proposed as a replacement for the fixed sample normal approximation test. A uniformly most efficient SPRT exists, however logistics suggest using a truncated SPRT. The truncated SPRT is evaluated in detail and shown to possess large potential savings in average time spent by employees in the monitoring process

  17. Comparative analysis through probability distributions of a data set

    Science.gov (United States)

    Cristea, Gabriel; Constantinescu, Dan Mihai

    2018-02-01

    In practice, probability distributions are applied in such diverse fields as risk analysis, reliability engineering, chemical engineering, hydrology, image processing, physics, market research, business and economic research, customer support, medicine, sociology, demography etc. This article highlights important aspects of fitting probability distributions to data and applying the analysis results to make informed decisions. There are a number of statistical methods available which can help us to select the best fitting model. Some of the graphs display both input data and fitted distributions at the same time, as probability density and cumulative distribution. The goodness of fit tests can be used to determine whether a certain distribution is a good fit. The main used idea is to measure the "distance" between the data and the tested distribution, and compare that distance to some threshold values. Calculating the goodness of fit statistics also enables us to order the fitted distributions accordingly to how good they fit to data. This particular feature is very helpful for comparing the fitted models. The paper presents a comparison of most commonly used goodness of fit tests as: Kolmogorov-Smirnov, Anderson-Darling, and Chi-Squared. A large set of data is analyzed and conclusions are drawn by visualizing the data, comparing multiple fitted distributions and selecting the best model. These graphs should be viewed as an addition to the goodness of fit tests.

  18. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  19. Clinical usefulness of serum free light chains measurement in patients with multiple myeloma: comparative analysis of two different tests

    Directory of Open Access Journals (Sweden)

    Tadeusz Kubicki

    2017-01-01

    Full Text Available Introduction: There are two commercially available tests for measurement of serum free light chains (sFLC in multiple myeloma (MM patients – Freelite and N Latex FLC. The aim of this study was to perform an assessment and direct comparison of the usefulness of the methods in routine clinical practice.Methods: 40 refractory/relapsed MM patients underwent routine disease activity assessment studies, along with sFLC analysis using both assays. Correlation and concordance between the tests and sensitivity of studied methods of sFLC assessment were established. Special attention was focused on sFLC results in patients finally evaluated after completing the treatment. Results: A weak correlation for the measurement of both κ [Passing–Bablok slope (PB = 0.7681] and λ chains [(PB = 1.542] was found. Using Bland–Altman plots, a bias of 0.0467 (κ and -0.2133 (λ between the measurements was documented. The concordance coefficient equaled 0.87 for κ, 0.62 for λ and 0.52 for κ/λ ratio. Ten patients had an abnormal Freelite assay κ/λ ratio and normal N Latex FLC κ/λ ratio. Three of these patients had negative serum protein electrophoresis results and fulfilled diagnostic criteria of stringent complete remission (sCR according to N Latex FLC (but not according to Freelite. When the κ/λ ratio obtained by both methods was compared to patients’ serum/urine protein electrophoresis and immunofixation results, sensitivity of Freelite and N Latex FLC was established to be 62.5% and 41%, respectively. Conclusions: There was no strong correlation or concordance between the two assays, and the sensitivity in terms of sFLC detection was different. This may cause problems when diagnosis of sCR is considered.

  20. Comparative evaluation of chest radiography, low-field MRI, the Shwachman-Kulczycki score and pulmonary function tests in patients with cystic fibrosis

    International Nuclear Information System (INIS)

    Anjorin, Angela; Vogl, Thomas J.; Schmidt, Helga; Posselt, Hans-Georg; Smaczny, Christina; Ackermann, Hanns; Deimling, Michael; Abolmaali, Nasreddin

    2008-01-01

    The aim of this study was to investigate whether the parenchymal lung damage in patients suffering from cystic fibrosis (CF) can be equivalently quantified by the Chrispin-Norman (CN) scores determined with low-field magnetic resonance imaging (MRI) and conventional chest radiography (CXR). Both scores were correlated with pulmonary function tests (PFT) and the Shwachman-Kulczycki method (SKM). To evaluate the comparability of MRI and CXR for different states of the disease, all scores were applied to patients divided into three age groups. Seventy-three CF patients (mean SKM score: 62 ± 8) with a median age (range) of 14 years (7-32) were included. The mean CN scores determined with both imaging methods were comparable (CXR: 12.1 ± 4.7; MRI: 12.0 ± 4.5) and showed high correlation (P < 0.05, R = 0.97). Only weak correlations were found between imaging, PFT, and SKM. Both imaging modalities revealed significantly more severe disease expression with age, while PFT and SKM failed to detect early signs of disease. We conclude that imaging of the lung in CF patients is capable of detecting subtle and early parenchymal destruction before lung function or clinical scoring is affected. Furthermore, low-field MRI revealed high consistency with chest radiography and may be used for a thorough follow-up while avoiding radiation exposure. (orig.)

  1. Comparative scrub solution tests for decontamination of transuranic radionuclides from soils

    International Nuclear Information System (INIS)

    Stevens, J.R.; Kochen, R.L.; Rutherford, D.W.; Riordan, G.A.; Delaney, I.C.

    1982-08-01

    Soil decontamination tests were done using three scrubbing solutions on five different transuranic-contaminated soils from Department of Energy sites. The soils came from Rocky Flats, Colorado; Hanford, Washington; Mound Facility, Ohio; Idaho National Engineering Laboratory, Idaho; and Los Alamos National Laboratory, New Mexico. Decontamination was effected by physical and chemical means. A pH 12.5 scrub effected decontamination by serving as a hydraulic grading and attrition scrub medium; this solution did not solubilize the actinide contamination. A 2% HNO 3 , 0.2% HF, 2% pine oil, and 5% Calgon solution effected decontamination by physical and chemical means; this solution solubilized particulate actinide and actinide dispersed on the surface of soil particles. A 2N HCl scrub was also used to effect decontamination by physical and chemical means; this reagent solubilized soil constituents, removing contamination that had migrated into mineral surfaces. Only Rocky Flats soil was effectively decontaminated by the high pH solution although all soils had an enrichment of the activity in the -150 mesh fraction. Attrition scrubbing with both acid solutions had a better decontamination ability for the +150 mesh fraction for Hanford, INEL, and LANL soils. In addition, the acid solutions solubilized some of the plutonium and had a decontamination effect on the fine fractions

  2. Mobile app reading speed test.

    Science.gov (United States)

    Kingsnorth, Alec; Wolffsohn, James S

    2015-04-01

    To validate the accuracy and repeatability of a mobile app reading speed test compared with the traditional paper version. Twenty-one subjects wearing their full refractive correction glasses read 14 sentences of decreasing print size between 1.0 and -0.1 logMAR, each consisting of 14 words (Radner reading speed test) at 40 cm with a paper-based chart and twice on iPad charts. Time duration was recorded with a stop watch for the paper chart and on the App itself for the mobile chart allowing critical print size (CPS) and optimal reading speed (ORS) to be derived objectively. The ORS was higher for the mobile app charts (194±29 wpm; 195±25 wpm) compared with the paper chart (166±20 wpm; F=57.000, pmobile app charts (0.17±0.20 logMAR; 0.18±0.17 logMAR) compared with the paper chart (0.25±0.17 logMAR; F=5.406, p=0.009). The mobile app test had a mean difference repeatability of 0.30±22.5 wpm, r=0.917 for ORS, and a CPS of 0.0±0.2 logMAR, r=0.769. Repeatability of the app reading speed test is as good (ORS) or better (CPS) than previous studies on the paper test. While the results are not interchangeable with paper-based charts, mobile app tablet-based tests of reading speed are reliable and rapid to perform, with the potential to capture functional visual ability in research studies and clinical practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. L-line x-ray fluorescence of cortical bone lead compared with the CaNa2EDTA test in lead-toxic children: public health implications

    International Nuclear Information System (INIS)

    Rosen, J.F.; Markowitz, M.E.; Bijur, P.E.; Jenks, S.T.; Wielopolski, L.; Kalef-Ezra, J.A.; Slatkin, D.N.

    1989-01-01

    Mild to moderate lead toxicity (blood lead, 25-55 micrograms/dl) is a preventable pediatric illness affecting several million preschool children (lead-toxic children) in the United States. In-hospital lead-chelation treatment is predicated upon a positive CaNa 2 EDTA test, which is difficult to perform and impractical in large populations. After the development of an L-line x-ray fluorescence technique (LXRF) that measures cortical bone lead content safely, rapidly, and noninvasively, this study was initiated in lead-toxic children to compare LXRF with the CaNa 2 EDTA test. Moreover, LXRF provided the opportunity to quantify bone lead content. From blood lead and LXRF alone, 90% of lead-toxic children were correctly classified as being CaNa 2 EDTA-positive or -negative. In 76% of 59 lead-toxic children, bone lead values measured by LXRF were equal to or greater than those measured in normal and industrially exposed adults. These results indicate that LXRF may be capable of replacing the CaNa 2 EDTA test. When considered with the known neurotoxic effects on children of low levels of exposure to lead, these results also suggest that either an excessively narrow margin of safety or insufficient safety is provided by present U.S. guidelines, which classify an elevated blood lead concentration as 25 micrograms/dl or greater

  4. Addressing unmet need for HIV testing in emergency care settings: a role for computer-facilitated rapid HIV testing?

    Science.gov (United States)

    Kurth, Ann E; Severynen, Anneleen; Spielberg, Freya

    2013-08-01

    HIV testing in emergency departments (EDs) remains underutilized. The authors evaluated a computer tool to facilitate rapid HIV testing in an urban ED. Randomly assigned nonacute adult ED patients were randomly assigned to a computer tool (CARE) and rapid HIV testing before a standard visit (n = 258) or to a standard visit (n = 259) with chart access. The authors assessed intervention acceptability and compared noted HIV risks. Participants were 56% nonWhite and 58% male; median age was 37 years. In the CARE arm, nearly all (251/258) of the patients completed the session and received HIV results; four declined to consent to the test. HIV risks were reported by 54% of users; one participant was confirmed HIV-positive, and two were confirmed false-positive (seroprevalence 0.4%, 95% CI [0.01, 2.2]). Half (55%) of the patients preferred computerized rather than face-to-face counseling for future HIV testing. In the standard arm, one HIV test and two referrals for testing occurred. Computer-facilitated HIV testing appears acceptable to ED patients. Future research should assess cost-effectiveness compared with staff-delivered approaches.

  5. Summary of HEDL sodium fire tests

    International Nuclear Information System (INIS)

    Hilliard, R.K.

    1979-01-01

    The sodium fire test program and related studies at the Hanford Engineering Development Laboratory (HEDL), covering the period from 1972 to 1978, are described. The program is analytical and experimental in scope, with computer code development and experimental verification. Tests have ranged in size from gram quantity laboratory tests to 1600-kg sodium spills. The experimental work is performed in two facilities: the Large Sodium Fire Facility (LSFF) and the Containment Systems Test Facility (CSTF). The facilities are described and the experimental results summarized. Sodium fire extinguishment tests which verified the Fast Flux Test Facility (FFTF) secondary sodium fire protection system are described and related information on sodium burning rates and smoke release rates are correlated. The burning rates are compared to theoretical predictions based on heat and mass transfer analogy, with good agreement. Comparisons with the SOFIRE-II code are also made. Sodium combustion aerosol properties are defined as to chemical and physical nature, settling in closed vessels and effect of added water vapor. The HAA-38 aerosol behaviour computer code is compared to tests in the 850-m 3 CSTF containment vessel. Sodium spray tests in the CSTF are compared with the SPRAY computer code. An air cleaning program is described, which has the objective of removing high mass concentration sodium combustion aerosols from vented cells and containment buildings. The aerosol mass holding capacity of commercial filters was measured and an aqueous scrubber system is described. The effects of sodium spills on cell structures were investigated, including water release from heated concrete, the reaction of sodium with concrete, the formation and spontaneous recombination of hydrogen, and the ability of steel cell liners to withstand large spills of high temperature sodium without leaking. (author)

  6. Summary of HEDL sodium fire tests

    Energy Technology Data Exchange (ETDEWEB)

    Hilliard, R K [Hanford Engineering Development Laboratory, Richland, WA (United States)

    1979-03-01

    The sodium fire test program and related studies at the Hanford Engineering Development Laboratory (HEDL), covering the period from 1972 to 1978, are described. The program is analytical and experimental in scope, with computer code development and experimental verification. Tests have ranged in size from gram quantity laboratory tests to 1600-kg sodium spills. The experimental work is performed in two facilities: the Large Sodium Fire Facility (LSFF) and the Containment Systems Test Facility (CSTF). The facilities are described and the experimental results summarized. Sodium fire extinguishment tests which verified the Fast Flux Test Facility (FFTF) secondary sodium fire protection system are described and related information on sodium burning rates and smoke release rates are correlated. The burning rates are compared to theoretical predictions based on heat and mass transfer analogy, with good agreement. Comparisons with the SOFIRE-II code are also made. Sodium combustion aerosol properties are defined as to chemical and physical nature, settling in closed vessels and effect of added water vapor. The HAA-38 aerosol behaviour computer code is compared to tests in the 850-m{sup 3} CSTF containment vessel. Sodium spray tests in the CSTF are compared with the SPRAY computer code. An air cleaning program is described, which has the objective of removing high mass concentration sodium combustion aerosols from vented cells and containment buildings. The aerosol mass holding capacity of commercial filters was measured and an aqueous scrubber system is described. The effects of sodium spills on cell structures were investigated, including water release from heated concrete, the reaction of sodium with concrete, the formation and spontaneous recombination of hydrogen, and the ability of steel cell liners to withstand large spills of high temperature sodium without leaking. (author)

  7. Asympotic efficiency of signed - rank symmetry tests under skew alternatives.

    OpenAIRE

    Alessandra Durio; Yakov Nikitin

    2002-01-01

    The efficiency of some known tests for symmetry such as the sign test, the Wilcoxon signed-rank test or more general linear signed rank tests was studied mainly under the classical alternatives of location. However it is interesting to compare the efficiencies of these tests under asymmetric alternatives like the so-called skew alternative proposed in Azzalini (1985). We find and compare local Bahadur efficiencies of linear signed-rank statistics for skew alternatives and discuss also the con...

  8. Predicting Freshman Grade Point Average From College Admissions Test Scores and State High School Test Scores

    OpenAIRE

    Koretz, Daniel; Yu, C; Mbekeani, Preeya Pandya; Langi, M.; Dhaliwal, Tasminda Kaur; Braslow, David Arthur

    2016-01-01

    The current focus on assessing “college and career readiness” raises an empirical question: How do high school tests compare with college admissions tests in predicting performance in college? We explored this using data from the City University of New York and public colleges in Kentucky. These two systems differ in the choice of college admissions test, the stakes for students on the high school test, and demographics. We predicted freshman grade point average (FGPA) from high school GPA an...

  9. Diagnosis of cystic fibrosis with chloride meter (Sherwood M926S chloride analyzer®) and sweat test analysis system (CFΔ collection system®) compared to the Gibson Cooke method.

    Science.gov (United States)

    Emiralioğlu, Nagehan; Özçelik, Uğur; Yalçın, Ebru; Doğru, Deniz; Kiper, Nural

    2016-01-01

    Sweat test with Gibson Cooke (GC) method is the diagnostic gold standard for cystic fibrosis (CF). Recently, alternative methods have been introduced to simplify both the collection and analysis of sweat samples. Our aim was to compare sweat chloride values obtained by GC method with other sweat test methods in patients diagnosed with CF and whose CF diagnosis had been ruled out. We wanted to determine if the other sweat test methods could reliably identify patients with CF and differentiate them from healthy subjects. Chloride concentration was measured with GC method, chloride meter and sweat test analysis system; also conductivity was determined with sweat test analysis system. Forty eight patients with CF and 82 patients without CF underwent the sweat test, showing median sweat chloride values 98.9 mEq/L with GC method, 101 mmol/L with chloride meter, 87.8 mmol/L with sweat test analysis system. In non-CF group, median sweat chloride values were 16.8 mEq/L with GC method, 10.5 mmol/L with chloride meter, and 15.6 mmol/L with sweat test analysis system. Median conductivity value was 107.3 mmol/L in CF group and 32.1 mmol/L in non CF group. There was a strong positive correlation between GC method and the other sweat test methods with a statistical significance (r=0.85) in all subjects. Sweat chloride concentration and conductivity by other sweat test methods highly correlate with the GC method. We think that the other sweat test equipments can be used as reliably as the classic GC method to diagnose or exclude CF.

  10. Fundamental symmetry tests with antihydrogen

    International Nuclear Information System (INIS)

    Hughes, R.J.

    1992-01-01

    The prospects for testing CPT invariance and the weak equivalence principle (WEP) for antimatter with spectroscopic measurements on antihydrogen are discussed. The potential precisions of these tests are compared with those from other measurements. The arguments involving energy conservation, the behavior of neutral kaons in a gravitational field and the equivalence principle for antiparticles are reviewed in detail

  11. Face Perception and Test Reliabilities in Congenital Prosopagnosia in Seven Tests

    Directory of Open Access Journals (Sweden)

    Janina Esins

    2016-01-01

    Full Text Available Congenital prosopagnosia, the innate impairment in recognizing faces, is a very heterogeneous disorder with different phenotypical manifestations. To investigate the nature of prosopagnosia in more detail, we tested 16 prosopagnosics and 21 controls with an extended test battery addressing various aspects of face recognition. Our results show that prosopagnosics exhibited significant impairments in several face recognition tasks: impaired holistic processing (they were tested amongst others with the Cambridge Face Memory Test (CFMT as well as reduced processing of configural information of faces. This test battery also revealed some new findings. While controls recognized moving faces better than static faces, prosopagnosics did not exhibit this effect. Furthermore, prosopagnosics had significantly impaired gender recognition—which is shown on a groupwise level for the first time in our study. There was no difference between groups in the automatic extraction of face identity information or in object recognition as tested with the Cambridge Car Memory Test. In addition, a methodological analysis of the tests revealed reduced reliability for holistic face processing tests in prosopagnosics. To our knowledge, this is the first study to show that prosopagnosics showed a significantly reduced reliability coefficient (Cronbach’s alpha in the CFMT compared to the controls. We suggest that compensatory strategies employed by the prosopagnosics might be the cause for the vast variety of response patterns revealed by the reduced test reliability. This finding raises the question whether classical face tests measure the same perceptual processes in controls and prosopagnosics.

  12. Value of stress ultrasound for the diagnosis of chronic ankle instability compared to manual anterior drawer test, stress radiography, magnetic resonance imaging, and arthroscopy.

    Science.gov (United States)

    Cho, Jae Ho; Lee, Doo Hyung; Song, Hyung Keun; Bang, Joon Young; Lee, Kyung Tai; Park, Young Uk

    2016-04-01

    Clinicians frequently diagnose chronic ankle instability using the manual anterior drawer test and stress radiography. However, both examinations can yield incorrect results and do not reveal the extent of ankle instability. Stress ultrasound has been reported to be a new diagnostic tool for the diagnosis of chronic ankle instability. The purpose of this study was to assess the diagnostic value of stress ultrasound for chronic ankle instability compared to the manual anterior drawer test, stress radiography, magnetic resonance imaging (MRI), and arthroscopy. Twenty-eight consecutive patients who underwent ankle arthroscopy and subsequent modified Broström repair for treatment of chronic ankle instability were included. The arthroscopic findings were used as the reference standard. A standardized physical examination (manual anterior drawer test), stress radiography, MRI, and stress ultrasound were performed to assess the anterior talofibular ligament (ATFL) prior to operation. Ultrasound images were taken in the resting position and the maximal anterior drawer position. Grade 3 lateral instability was verified arthroscopically in all 28 cases with a clinical diagnosis (100%). Twenty-two cases showed grade III instability on the manual anterior drawer test (78.6%). Twenty-four cases displayed anterior translation exceeding 5 mm on stress radiography (86%), and talar tilt angle exceeded 15° in three cases (11 %). Nineteen cases displayed a partial chronic tear (change in thickness or signal intensity), and nine cases displayed complete tear on MRI (100%). Lax and wavy ATFL was evident on stress ultrasound in all cases (100 %). The mean value of the ATFL length was 2.8 ± 0.3 cm for the stressed condition and 2.1 ± 0.2 cm for the resting condition (p radiography. III.

  13. Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests.

    Science.gov (United States)

    Zahouani, H; Pailler-Mattei, C; Sohm, B; Vargiolu, R; Cenizo, V; Debret, R

    2009-02-01

    The study of changes in skin structure with age is becoming all the more important with the increase in life. The atrophy that occurs during aging is accompanied by more profound changes, with a loss of organization within the elastic collagen network and alterations in the basal elements. The aim of this study is to present a method to determine the mechanical properties of total human skin in vivo compared with dermal equivalents (DEs) using indentation and static friction tests. A new bio-tribometer working at a low contact pressure for the characterization the mechanical properties of the skin has been developed. This device, based on indentation and static friction tests, also allows to characterize the skin in vivo and reconstructed DEs in a wide range of light contact forces, stress and strain. This original bio-tribometer shows the ability to assess the skin elasticity and friction force in a wide range of light normal load (0.5-2 g) and low contact pressure (0.5-2 kPa). The results obtained by this approach show identical values of the Young's modulus E(*) and the shear modulus G(*) of six DEs obtained from a 62-year-old subject (E(*)=8.5+/-1.74 kPa and G(*)=3.3+/-0.46 kPa) and in vivo total skin of 20 subjects aged 55 to 70 years (E(*)=8.3+/-2.1 kPa, G(*)=2.8+/-0.8 kpa).

  14. Performance assessment of the Greater Confinement Disposal facility on the Nevada Test Site: Comparing the performance of two conceptual site models

    International Nuclear Information System (INIS)

    Baer, T.A.; Price, L.L.; Gallegos, D.P.

    1993-01-01

    A small amount of transuranic (TRU) waste has been disposed of at the Greater Confinement Disposal (GCD) site located on the Nevada Test Site's (NTS) Radioactive Waste Management Site (RWMS). The waste has been buried in several deep (37 m) boreholes dug into the floor of an alluvial basin. For the waste to remain in its current configuration, the DOE must demonstrate compliance of the site with the TRU disposal requirements, 40 CFR 191. Sandia's approach to process modelling in performance assessment is to use demonstrably conservative models of the site. Choosing the most conservative model, however, can be uncertain. As an example, diffusion of contaminants upward from the buried waste in the vadose zone water is the primary mechanism of release. This process can be modelled as straight upward planar diffusion or as spherical diffusion in all directions. The former has high fluxes but low release areas, the latter has lower fluxes but is spread over a greater area. We have developed analytic solutions to a simple test problem for both models and compared the total integrated discharges. The spherical diffusion conceptual model results in at least five times greater release to the accessible environment than the planar model at all diffusivities. Modifying the planar model to allow for a larger release, however, compensated for the smaller original planar discharge and resulted in a new planar model that was more conservative that the spherical model except at low diffusivities

  15. Influence of selected test parameters on measured values during the MSCR test

    Science.gov (United States)

    Benešová, Lucie; Valentin, Jan

    2017-09-01

    One of today’s most commonly used test on a Dynamic Shear Rheometer (DSR) is the Multiple Stress Creep Recovery (MSCR) test. The test is described in the standard EN 16659, which is valid in the Czech Republic since October 2016. The principle of the test is based on repeated loading and recovering of a bitumen sample, according to which it is possible to determine the percentage of elastic recovery (R) and non-recoverable creep compliance (Jnr) of the bituminous binder. This method has been recently promoted as the most suitable test for assessing the resistance of bituminous binders to permanent deformation. The test is performed at higher temperatures and is particularly suitable for modified bituminous binders. The paper deals with the comparison of the different input parameters set on the DSR device - different levels of stress, temperature of test, the geometry of the measuring device and also a comparison of the results for a different number of loading cycles. The research study was focused mainly on modified bituminous binders, but to compare the MSCR test it is performed even with conventional paving grade binders.

  16. Semantics bias in cross-national comparative analyses

    DEFF Research Database (Denmark)

    Schnohr, Christina W.; Gobina, Inese; Santos, Teresa

    2016-01-01

    indicates that there are what may be called semantic issues affecting comparability in international studies, since the same original word (in an English original) is interpreted differently across countries and cultures. The paper test and discuss a few possible explanations to this, however, only leaving...

  17. Comparative evaluation of immunochromatographic dipstick test (ICT) rk39, soluble antigen ELISA and IFAT for the sero-diagnosis of visceral leishmaniasis in Morocco.

    Science.gov (United States)

    Mniouil, Meryem; Fellah, Hajiba; Amarir, Fatima; Sadak, Abderrahim; Et-Touys, Abdeslam; Bakri, Youssef; Moustachi, Aziza; Tassou, Fatima Zahraa; Hida, Mostapha; Lyagoubi, Mohamed; Adlaoui, El Bachir; Rhajaoui, Mohamed; Sebti, Faiza

    2018-06-01

    A rapid, sensitive and specific tool for detection of Leishmania infantum infection in Humans would be highly desirable, because it would allow control interventions in endemic areas of visceral leishmaniasis. This study was carried out at the Reference National Laboratory of Leishmaniasis (RNLL) in National Institute of Hygiene (NIH) Morocco, in order to evaluate the diagnostic potential of immunochromatographic dipstick test (ICT) rk39 in Moroccan suspected VL patients. A total of 49 admitted patients with strong clinical suspicion of VL and 40 healthy controls were investigated for the performance of the ICT rk39. Bone marrow smears were examined for microscopic detection of Leishmania amastigotes obtained from the admitted patients. Only PCR and smear positive cases were considered as gold standard as well as confirmed cases of VL. Out of 49 suspected patients, twenty four (48.9%) were found PCR and smear-positive and twenty three (46.9%) were positive for ICT rk39. Voluntary healthy controls, which included twenty persons from the endemic zone and twenty from non-endemic zone of VL, were found all negative for the strip test. The sensitivity in sera was 75% by ELISA and 87.5% by IFAT, compared with 95.8% for ICT rk39. Specificity was 95.8%, with both tests ELISA and IFAT, and 100% by ICT rk39 respectively. Present study findings again reinforce that the ICT rk39 is a simple, reliable and easy-to-perform non-invasive diagnostic tool for visceral leishmaniasis in the endemic area of Morocco. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. FUJI - a comparative irradiation test with pellet, sphere-pac, and vipac fuel

    International Nuclear Information System (INIS)

    Hellwig, C.; Bakker, K.; Ozawa, T.; Nakamura, M.; Kihara, Y.

    2004-01-01

    Particle fuels such as sphere-pac and vipac fuels have been considered as promising fuel systems for fast reactors, due to their inherent potential in remote operation, cost reduction and incineration of minor actinides or low-decontaminated plutonium. The FUJI test addresses the questions of fabrication of MOX particle fuels with high Pu content (20%) and its irradiation behaviour during the start-up phase. Four kinds of fuel, i.e. MOX sphere-pac, MOX vipac, MOX pellet and Np-MOX sphere-pac fuel, have been and will be simultaneously irradiated under identical conditions in the High Flux Reactor in Petten. First results show that the particle fuel undergoes a dramatic structure change already at the very beginning of the irradiation when the maximum power is reached. The structural changes, i.e. the formation of a central void and the densification of fuel, decrease the fuel central temperature. Thus the fast and strong restructuring helps to prevent central fuel melting at high power levels. (authors)

  19. Prediction of clinical response to drugs in ovarian cancer using the chemotherapy resistance test (CTR-test).

    Science.gov (United States)

    Kischkel, Frank Christian; Meyer, Carina; Eich, Julia; Nassir, Mani; Mentze, Monika; Braicu, Ioana; Kopp-Schneider, Annette; Sehouli, Jalid

    2017-10-27

    In order to validate if the test result of the Chemotherapy Resistance Test (CTR-Test) is able to predict the resistances or sensitivities of tumors in ovarian cancer patients to drugs, the CTR-Test result and the corresponding clinical response of individual patients were correlated retrospectively. Results were compared to previous recorded correlations. The CTR-Test was performed on tumor samples from 52 ovarian cancer patients for specific chemotherapeutic drugs. Patients were treated with monotherapies or drug combinations. Resistances were classified as extreme (ER), medium (MR) or slight (SR) resistance in the CTR-Test. Combination treatment resistances were transformed by a scoring system into these classifications. Accurate sensitivity prediction was accomplished in 79% of the cases and accurate prediction of resistance in 100% of the cases in the total data set. The data set of single agent treatment and drug combination treatment were analyzed individually. Single agent treatment lead to an accurate sensitivity in 44% of the cases and the drug combination to 95% accuracy. The detection of resistances was in both cases to 100% correct. ROC curve analysis indicates that the CTR-Test result correlates with the clinical response, at least for the combination chemotherapy. Those values are similar or better than the values from a publication from 1990. Chemotherapy resistance testing in vitro via the CTR-Test is able to accurately detect resistances in ovarian cancer patients. These numbers confirm and even exceed results published in 1990. Better sensitivity detection might be caused by a higher percentage of drug combinations tested in 2012 compared to 1990. Our study confirms the functionality of the CTR-Test to plan an efficient chemotherapeutic treatment for ovarian cancer patients.

  20. Comparing heat flow models for interpretation of precast quadratic pile heat exchanger thermal response tests

    DEFF Research Database (Denmark)

    Alberdi Pagola, Maria; Poulsen, Søren Erbs; Loveridge, Fleur

    2018-01-01

    This paper investigates the applicability of currently available analytical, empirical and numerical heat flow models for interpreting thermal response tests (TRT) of quadratic cross section precast pile heat exchangers. A 3D finite element model (FEM) is utilised for interpreting five TRTs by in...