WorldWideScience

Sample records for combined-cycle power plant

  1. Maximisation of Combined Cycle Power Plant Efficiency

    Directory of Open Access Journals (Sweden)

    Janusz Kotowicz

    2015-12-01

    Full Text Available The paper presents concepts for increasing the efficiency of a modern combined cycle power plant. Improvement of gas turbine performance indicators as well as recovering heat from the air cooling the gas turbine’s flow system enable reaching gross electrical efficiencies of around 65%. Analyses for a wide range of compressor pressure ratios were performed. Operating characteristics were developed for the analysed combined cycle plant, for different types of open air cooling arrangements of the gas turbine’s expander: convective, transpiration and film.

  2. Thermodynamic Analysis of Combined Cycle Power Plant

    Directory of Open Access Journals (Sweden)

    A.K.Tiwari,

    2010-04-01

    Full Text Available Air Bottoming Cycle (ABC can replace the heat recovery steam generator and the steam turbine of the conventionalcombined cycle plant. The exhaust energy of the topping gas turbine of existing combine cycle is sent to gas-air heat exchange, which heats the air in the secondary gas turbine cycle. In 1980’s the ABC was proposed as an alternative for the conventional steam bottoming cycle. In spite of the cost of reducing hardware installations it could achieve a thermal efficiency of 80%. The complete thermodynamic analysis of the system has been performed by using specially designed programme, enabling the variation of main independent variables. The result shows the gain in net work output as well as efficiency of combined cycle is 35% to 68%.

  3. Effective Parameters on Performance of Multipressure Combined Cycle Power Plants

    OpenAIRE

    Thamir K. Ibrahim; Rahman, M M

    2014-01-01

    A parametric analysis is performed for numerous configurations of a combined cycle gas turbine (CCGT) power plant, including single-pressure, double-pressure, triple-pressure, triple-pressure with reheat, and supplementary triple-pressure with reheat. The compression ratio of the gas turbine and the steam pressure of the steam turbine are taken as design parameters. The thermodynamic model was developed based on an existing MARAFIQ CCGT power plant and performance model code developed using t...

  4. Technical comparison between Integrated Gasification Combined Cycle (IGCC) and Natural Gas Combined Cycle (NGCC) power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, Pablo Andres Silva; Venturini, Osvaldo Jose; Lora, Electo Eduardo Silva [Federal University of Itajuba - UNIFEI, MG (Brazil). Excellence Group in Thermal Power and Distributed Generation - NEST], e-mails: osvaldo@unifei.edu.br, electo@unifei.edu.br

    2010-07-01

    Among the emerging clean coal technologies for power generation, Integrated Gasification Combined Cycle (IGCC) and Natural Gas Combined Cycle (NGCC) systems are receiving considerable attention as a potentially attractive option to reduce the emissions of greenhouse gases (GHG). The main reason is because these systems has high efficiency and low emissions in comparison with traditional power generation plants. Currently in IGCC and NGCC systems at demonstration stage is been considered to implement CCS technology. CO{sub 2} emissions can be avoided in a gasification-based power plant because by transferring almost all carbon compounds to CO{sub 2} through the water gas shift (WGS) reaction, then removing the CO{sub 2} before it is diluted in the combustion stage. The aim of this study is to compare the technical performance of an IGCC system that uses Brazilian coal and petroleum coke as fuel with a NGCC system, with the same fixed output power of 450 MW. The first section of this paper presents the plant configurations of IGCC systems. The following section presents an analysis of NGCC technology. (author)

  5. Model Predictive Control of Integrated Gasification Combined Cycle Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    B. Wayne Bequette; Priyadarshi Mahapatra

    2010-08-31

    The primary project objectives were to understand how the process design of an integrated gasification combined cycle (IGCC) power plant affects the dynamic operability and controllability of the process. Steady-state and dynamic simulation models were developed to predict the process behavior during typical transients that occur in plant operation. Advanced control strategies were developed to improve the ability of the process to follow changes in the power load demand, and to improve performance during transitions between power levels. Another objective of the proposed work was to educate graduate and undergraduate students in the application of process systems and control to coal technology. Educational materials were developed for use in engineering courses to further broaden this exposure to many students. ASPENTECH software was used to perform steady-state and dynamic simulations of an IGCC power plant. Linear systems analysis techniques were used to assess the steady-state and dynamic operability of the power plant under various plant operating conditions. Model predictive control (MPC) strategies were developed to improve the dynamic operation of the power plants. MATLAB and SIMULINK software were used for systems analysis and control system design, and the SIMULINK functionality in ASPEN DYNAMICS was used to test the control strategies on the simulated process. Project funds were used to support a Ph.D. student to receive education and training in coal technology and the application of modeling and simulation techniques.

  6. ISCC Kuraymat Integrated Solar Combined Cycle Power Plant in Egypt

    Energy Technology Data Exchange (ETDEWEB)

    Brakmann, G.

    2006-07-01

    The New and Renewable Energy Authority (NREA) of Egypt intends to implement an Integrated Solar Combined Cycle Power Plant, ISCC Kuraymat, to be located about 95 km south of Cairo, on the eastern side of the river Nile, at a northern latitude of 29{sup o} 16' and an eastern longitude of 31{sup o} 15'. The complete ISCC Project shall be implemented in three (3) contract lots: One (1) Contract Lot for Solar Island as EPC cum OandM contract for engineering, procurement, construction, testing, commissioning and five (5) years operation and maintenance; (Two contracts will be used for this Lot (Solar Island), one for EPC and one for the OandM part of the Lot.) The Solar Island shall consist of a parabolic trough solar field capable to generate about 110 MW (thermal) of solar heat at a temperature of 393{sup o}C, the related IandC and control room and the heat transfer fluid (HTF) system up to the HTF inlet and outlet flanges of the Solar Heat Exchanger(s). The Contractor for Solar Island shall guarantee the supply of solar heat to the Solar Heat Exchanger(s) as a function of normal direct solar irradiation (DNI) and of solar position. One (1) Contract for Combined Cycle Island as EPC contract for engineering, procurement, construction, testing and commissioning and extended two (2) year warranty period. The Combined Cycle Island shall consist of one (1) or two (2) gas turbine(s) with ISO rating of about 80 MWe (total), one (1) or two (2) heat recovery steam generator(s) (HRSG), one (1) steam turbine of about 70 MWe, solar heat exchanger(s) capable to absorb about 110 MW (thermal) of solar heat plus all associated balance of plant equipment. The Contractor(s) for Combined Cycle Island shall guarantee the supply of electricity and the heat rate as a function of ambient temperature and as a function of solar heat supply from the Solar Island. One (1) Contract for Combined Cycle Island as OandM contract for five (5) year operation and maintenance. (Author)

  7. Gas--steam turbine combined cycle power plants

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1978-10-01

    The purpose of this technology evaluation is to provide performance and cost characteristics of the combined gas and steam turbine, cycle system applied to an Integrated Community Energy System (ICES). To date, most of the applications of combined cycles have been for electric power generation only. The basic gas--steam turbine combined cycle consists of: (1) a gas turbine-generator set, (2) a waste-heat recovery boiler in the gas turbine exhaust stream designed to produce steam, and (3) a steam turbine acting as a bottoming cycle. Because modification of the standard steam portion of the combined cycle would be necessary to recover waste heat at a useful temperature (> 212/sup 0/F), some sacrifice in the potential conversion efficiency is necessary at this temperature. The total energy efficiency ((electric power + recovered waste heat) divided by input fuel energy) varies from about 65 to 73% at full load to 34 to 49% at 20% rated electric power output. Two major factors that must be considered when installing a gas--steam turbine combines cycle are: the realiability of the gas turbine portion of the cycle, and the availability of liquid and gas fuels or the feasibility of hooking up with a coal gasification/liquefaction process.

  8. Increasing of Manoeuvrability of Cogeneration Combined Cycle Power Plants Owing to the Usage of Electric Boilers

    Directory of Open Access Journals (Sweden)

    S. Kachan

    2013-01-01

    Full Text Available The paper contains the results of efficiency evaluation  of using the electric boilers to improve maneuver capabilities of the cogeneration combined cycle power plants (as an example, 230 MW combined cycle unit of Minsk CHP-3 in comparison with the traditional steam-turbine units of cogeneration power plants.

  9. Catalytic combustor for integrated gasification combined cycle power plant

    Science.gov (United States)

    Bachovchin, Dennis M.; Lippert, Thomas E.

    2008-12-16

    A gasification power plant 10 includes a compressor 32 producing a compressed air flow 36, an air separation unit 22 producing a nitrogen flow 44, a gasifier 14 producing a primary fuel flow 28 and a secondary fuel source 60 providing a secondary fuel flow 62 The plant also includes a catalytic combustor 12 combining the nitrogen flow and a combustor portion 38 of the compressed air flow to form a diluted air flow 39 and combining at least one of the primary fuel flow and secondary fuel flow and a mixer portion 78 of the diluted air flow to produce a combustible mixture 80. A catalytic element 64 of the combustor 12 separately receives the combustible mixture and a backside cooling portion 84 of the diluted air flow and allows the mixture and the heated flow to produce a hot combustion gas 46 provided to a turbine 48. When fueled with the secondary fuel flow, nitrogen is not combined with the combustor portion.

  10. Thermodynamic analysis of heat recovery steam generator in combined cycle power plant

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Naradasu

    2007-01-01

    Full Text Available Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is proper utilization of gas turbine exhaust heat in the steam cycle in order to achieve optimum steam turbine output. Most of the combined cycle developers focused on the gas turbine output and neglected the role of the heat recovery steam generator which strongly affects the overall performance of the combined cycle power plant. The present paper is aimed at optimal utilization of the flue gas recovery heat with different heat recovery steam generator configurations of single pressure and dual pressure. The combined cycle efficiency with different heat recovery steam generator configurations have been analyzed parametrically by using first law and second law of thermodynamics. It is observed that in the dual cycle high pressure steam turbine pressure must be high and low pressure steam turbine pressure must be low for better heat recovery from heat recovery steam generator.

  11. Energetic analysis and optimisation of an integrated coal gasification-combined cycle power plant

    NARCIS (Netherlands)

    Vlaswinkel, E.E.

    1992-01-01

    Methods are presented to analyse and optimise the energetic performance of integrated coal gasification-combined cycle (IGCC) power plants. The methods involve exergy analysis and pinch technology and can be used to identify key process parameters and to generate alternative design options for impro

  12. Innovative open air brayton combined cycle systems for the next generation nuclear power plants

    Science.gov (United States)

    Zohuri, Bahman

    The purpose of this research was to model and analyze a nuclear heated multi-turbine power conversion system operating with atmospheric air as the working fluid. The air is heated by a molten salt, or liquid metal, to gas heat exchanger reaching a peak temperature of 660 0C. The effects of adding a recuperator or a bottoming steam cycle have been addressed. The calculated results are intended to identify paths for future work on the next generation nuclear power plant (GEN-IV). This document describes the proposed system in sufficient detail to communicate a good understanding of the overall system, its components, and intended uses. The architecture is described at the conceptual level, and does not replace a detailed design document. The main part of the study focused on a Brayton --- Rankine Combined Cycle system and a Recuperated Brayton Cycle since they offer the highest overall efficiencies. Open Air Brayton power cycles also require low cooling water flows relative to other power cycles. Although the Recuperated Brayton Cycle achieves an overall efficiency slightly less that the Brayton --- Rankine Combined Cycle, it is completely free of a circulating water system and can be used in a desert climate. Detailed results of modeling a combined cycle Brayton-Rankine power conversion system are presented. The Rankine bottoming cycle appears to offer a slight efficiency advantage over the recuperated Brayton cycle. Both offer very significant advantages over current generation Light Water Reactor steam cycles. The combined cycle was optimized as a unit and lower pressure Rankine systems seem to be more efficient. The combined cycle requires a lot less circulating water than current power plants. The open-air Brayton systems appear to be worth investigating, if the higher temperatures predicted for the Next Generation Nuclear Plant do materialize.

  13. Advanced power plant concepts based on CFB combustion and combined cycles

    Energy Technology Data Exchange (ETDEWEB)

    Plass, L.; Beisswenger, H.; Anders, R. (Lurgi GmbH, Frankfurt am Main (Germany, F.R.). Coal and Energy Division)

    1990-01-01

    The paper describes several power plants employing circulating fluidized bed (CFB) technology. The Moabit power plant of BEWAG (Berliner Kraft und Licht Aktiengesellschaft) supplies electric power and steam for district heating. The Charbonnages de France group has built a 367 t/h CFB boiler with reheat at the Emile Huchet power station in Carling, Lorraine France. This uses dry fuel but operation with slurry feed is scheduled soon. The 150 MWe CFB boiler operated by Texas New Mexico Power Company is the largest CFB boiler worldwide. Salient features of boiler design for these plants are discussed. All meet requirements for low SO{sub 2} and NO{sub x} and particulate emission but have been developed to the full. Improved efficiency and low emission levels can be met by combined cycle power plants employing coal gasification. Demonstration plants for example using the BGL-fixed bed gasifier are mentioned. 1 ref., 13 figs., 7 tabs.

  14. Combined cycle power unit with a binary system based on waste geothermal brine at Mutnovsk geothermal power plant

    Science.gov (United States)

    Tomarov, G. V.; Shipkov, A. A.; Nikol'skii, A. I.; Semenov, V. N.

    2016-06-01

    The Russian geothermal power systems developed in the last few decades outperform their counterparts around the world in many respects. However, all Russian geothermal power stations employ steam as the geothermal fluid and discard the accompanying geothermal brine. In reality, the power of the existing Russian geothermal power stations may be increased without drilling more wells, if the waste brine is employed in combined cycle systems with steam and binary turbine units. For the example of the 50 MW Mutnovsk geothermal power plant, the optimal combined cycle power unit based on the waste geothermal brine is considered. It is of great interest to determine how the thermodynamic parameters of the secondary steam in the expansion unit and the pressure in the condenser affect the performance of the equipment in the combined cycle power unit at Mutnovsk geothermal power plant. For the utilization of the waste geothermal brine at Mutnovsk geothermal power plant, the optimal air temperature in the condensers of the combined cycle power unit is +5°C. The use of secondary steam obtained by flashing of the geothermal brine at Mutnovsk geothermal power plant 1 at a pressure of 0.2 MPa permits the generation of up to 8 MW of electric power in steam turbines and additional power of 5 MW in the turbines of the binary cycle.

  15. Valuing flexibility: The case of an Integrated Gasification Combined Cycle power plant

    Energy Technology Data Exchange (ETDEWEB)

    Abadie, L.M.; Chamorro, J.M. [University of the Basque Country, Bilbao (Spain)

    2008-07-15

    In this paper we analyze the choice between two technologies for producing electricity. In particular, the firm has to decide whether and when to invest either in a Natural Gas Combined Cycle (NGCC) power plant or in an Integrated Gasification Combined Cycle (IGCC) power plant, which may burn either coal or natural gas. Instead of assuming that fuel prices follow standard geometric Brownian motions' here they are assumed to show mean reversion, specifically to follow an inhomogeneous geometric Brownian motion. First we consider the opportunity to invest in a NGCC power plant. We derive the optimal investment rule as a function of natural gas price and the remaining life of the right to invest. In addition, the analytical solution for a perpetual option to invest is obtained. Then we turn to the IGCC power plant. We analyse the valuation of an operating plant when there are switching costs between modes of operation, and the choice of the best operation mode. This serves as an input to evaluate the option to invest in this plant. Finally we derive the value of an opportunity to invest either in a NGCC or IGCC power plant, i.e. to choose between an inflexible and a flexible technology, respectively. Depending on the opportunity's time to maturity, we derive the pairs of coal and gas prices for which it is optimal to invest in NGCC, in IGCC, or simply not to invest. Numerical computations involve the use of one- and two-dimensional binomial lattices that support a mean-reverting process for coal and gas prices. Basic parameter values are taken from an actual IGCC power plant currently in operation. sensitivity of some results with respect to the underlying stochastic process for fuel price is also checked.

  16. Monitoring of the thermoeconomic performance in an actual combined cycle power plant bottoming cycle

    Energy Technology Data Exchange (ETDEWEB)

    Cafaro, S.; Napoli, L.; Traverso, A.; Massardo, A.F. [DIMSET (TPG), University of Genoa, Via Montallegro 1, 16145 Genoa (Italy)

    2010-02-15

    This paper presents a research project carried out by TPG (Thermochemical Power Group) of University of Genoa to develop innovative monitoring and diagnostics procedures and software tools for software-aided maintenance and customer support. This work is concerned with preliminary outcomes regarding the thermoeconomic monitoring of the bottoming cycle of a combined cycle power plant, using real historical data. The software is able to calculate functional exergy flows (y), their related costs (c) (using the plant functional diagram); after that non dimensional parameters for the characteristic exergonomic indexes ({delta}c, {delta}c*, {delta}k*) are determined. Through a plant optimization (not described here) the reference conditions of the plant at each operating condition can be determined. Then, non dimensional indexes related to each thermoeconomic parameter are defined, in order to depict a ''cost degradation'', and thus a significant rise in the production cost of the main products of the bottoming cycle (steam and power). The methodology developed has been successfully applied to historical logged data of an existing 400 MW power plant, showing the capabilities in estimating the ''cost degradation'' of the elements of the BC over the plant life, and trends in the thermoeconomic indexes. (author)

  17. Effect of Gas Turbine Exhaust Temperature, Stack Temperature and Ambient Temperature on Overall Efficiency of Combine Cycle Power Plant

    OpenAIRE

    Khan, M N; K.P.Tyagi

    2010-01-01

    The gas turbine exhaust temperature, stack temperature and ambient temperature play a very important role during the predication of the performance of combine cycle power plant. This paper covers parametric analysis of effects of gas turbine exhaust temperature, stack temperature and ambient temperature on the overall efficiency of combine cycle power plant keeping the gas turbine efficiency as well as steam turbine efficiency constant. The results shows that out of three variables i.e. turbi...

  18. The cost of carbon capture and storage for natural gas combined cycle power plants.

    Science.gov (United States)

    Rubin, Edward S; Zhai, Haibo

    2012-03-20

    This paper examines the cost of CO(2) capture and storage (CCS) for natural gas combined cycle (NGCC) power plants. Existing studies employ a broad range of assumptions and lack a consistent costing method. This study takes a more systematic approach to analyze plants with an amine-based postcombustion CCS system with 90% CO(2) capture. We employ sensitivity analyses together with a probabilistic analysis to quantify costs for plants with and without CCS under uncertainty or variability in key parameters. Results for new baseload plants indicate a likely increase in levelized cost of electricity (LCOE) of $20-32/MWh (constant 2007$) or $22-40/MWh in current dollars. A risk premium for plants with CCS increases these ranges to $23-39/MWh and $25-46/MWh, respectively. Based on current cost estimates, our analysis further shows that a policy to encourage CCS at new NGCC plants via an emission tax or carbon price requires (at 95% confidence) a price of at least $125/t CO(2) to ensure NGCC-CCS is cheaper than a plant without CCS. Higher costs are found for nonbaseload plants and CCS retrofits.

  19. Evaluation of Coal Gasification/Combined Cycle Power Plant Feasibility at the Sewells Point Naval Complex, Norfolk, Virginia.

    Science.gov (United States)

    1981-07-01

    This study evaluates the feasibility of installing a coal gasification /combined cycle cogeneration plant at Sewells Point Naval Complex, Norfolk...fired cogeneration cycles. The utility interface, site considerations and economic analyses are also presented. The study includes that a coal ... gasification /combined cycle cogeneration plant supplying 50 MW of electric power and 290,000 lb/hr of steam is technically feasible. (Author)

  20. Evaluation of Coal Gasification/Combined Cycle Power Plant Feasibility at the Sewells Point Naval Complex, Norfolk, Virginia. Summary.

    Science.gov (United States)

    1981-07-01

    This study evaluates the feasibility of installing a coal gasification /combined cycle cogeneration plant at Sewells Point Naval Complex, Norfolk...fired cogeneration cycles. The utility interface, site considerations and economic analyses are also presented. The study concludes that a coal ... gasification /combined cycle cogeneration plant supplying 50 MW of electric power and 290,000 lb/hr of steam is technically feasible. (Author)

  1. Exergetic Analysis of a Novel Solar Cooling System for Combined Cycle Power Plants

    Directory of Open Access Journals (Sweden)

    Francesco Calise

    2016-09-01

    Full Text Available This paper presents a detailed exergetic analysis of a novel high-temperature Solar Assisted Combined Cycle (SACC power plant. The system includes a solar field consisting of innovative high-temperature flat plate evacuated solar thermal collectors, a double stage LiBr-H2O absorption chiller, pumps, heat exchangers, storage tanks, mixers, diverters, controllers and a simple single-pressure Combined Cycle (CC power plant. Here, a high temperature solar cooling system is coupled with a conventional combined cycle, in order to pre-cool gas turbine inlet air in order to enhance system efficiency and electrical capacity. In this paper, the system is analyzed from an exergetic point of view, on the basis of an energy-economic model presented in a recent work, where the obtained main results show that SACC exhibits a higher electrical production and efficiency with respect to the conventional CC. The system performance is evaluated by a dynamic simulation, where detailed simulation models are implemented for all the components included in the system. In addition, for all the components and for the system as whole, energy and exergy balances are implemented in order to calculate the magnitude of the irreversibilities within the system. In fact, exergy analysis is used in order to assess: exergy destructions and exergetic efficiencies. Such parameters are used in order to evaluate the magnitude of the irreversibilities in the system and to identify the sources of such irreversibilities. Exergetic efficiencies and exergy destructions are dynamically calculated for the 1-year operation of the system. Similarly, exergetic results are also integrated on weekly and yearly bases in order to evaluate the corresponding irreversibilities. The results showed that the components of the Joule cycle (combustor, turbine and compressor are the major sources of irreversibilities. System overall exergetic efficiency was around 48%. Average weekly solar collector

  2. Modelling and Stability of a Single-Shaft Combined Cycle Power Plant

    Directory of Open Access Journals (Sweden)

    Costas Vournas

    2007-06-01

    Full Text Available The subject of this paper is the development of a dynamic model for a single-shaft combined cycle plant and the analysis of its response to electrical load and frequency transients. In particular the stability of the frequency control, as well as the implications of overheat control are investigated. The model is developed in the Simulink environment of Matlab as part of an educational and research simulation package for autonomous and interconnected systems.

  3. Analyzing the possibility of constructing the air heating system for an integrated solid fuel gasification combined-cycle power plant

    Science.gov (United States)

    Mikula, V. A.; Ryzhkov, A. F.; Val'tsev, N. V.

    2015-11-01

    Combined-cycle power plants operating on solid fuel have presently been implemented only in demonstration projects. One of possible ways for improving such plants consists in making a shift to hybrid process circuits of integrated gasification combined-cycle plants with external firing of solid fuel. A high-temperature air heater serving to heat compressed air is a key element of the hybrid process circuit. The article describes application of a high-temperature recuperative metal air heater in the process circuit of an integrated gasification combined-cycle power plant (IGCC). The available experience with high-temperature air heating is considered, and possible air heater layout arrangements are analyzed along with domestically produced heat-resistant grades of steel suitable for manufacturing such air heater. An alternative (with respect to the traditional one) design is proposed, according to which solid fuel is fired in a noncooled furnace extension, followed by mixing the combustion products with recirculation gases, after which the mixture is fed to a convective air heater. The use of this design makes it possible to achieve considerably smaller capital outlays and operating costs. The data obtained from thermal and aerodynamic calculations of the high-temperature air heater with a thermal capacity of 258 MW for heating air to a temperature of up to 800°C for being used in the hybrid process circuit of a combined-cycle power plant are presented.

  4. Sub-atmospheric disk generators for coal-fired MHD/steam combined cycle power plant

    Energy Technology Data Exchange (ETDEWEB)

    Messerle, H.K.; Fang, Y.; Simpson, S.W.; Marty, S.M. (Sydney Univ. (Australia). School of Electrical Engineering)

    1989-01-01

    A coal fired MHD disk generator in a combined cycle MHD/steam power generation system with a diffuser operating at sub-atmospheric pressure is proposed. The effects of pressure on the performance of a radial outflow MHD disk generator and other system components are analysed. Using a previous study as a reference case, preliminary calculations show that, in such a sub-atmospheric system, improved power station efficiency can be achieved. In addition, operation at reduced values of magnetic field strength would be feasible. Calculations have also been carried out for a 30 MW{sub th} experimental disk generator operating at reduced pressure with a magnetic field strength of 2 T. Flow conditions at sub-atmospheric pressure would provide an improved simulation of a full-scale generator operating at normal pressures. (author).

  5. Exergy Analysis of Gas Turbine – Fuel cell based combined Cycle Power Plant

    Directory of Open Access Journals (Sweden)

    M.Sreeramulu,

    2011-06-01

    Full Text Available The increase in demand for electrical energy leads to the newer power generation systems. Though it is not new, fuel cell technology is one of the promising systems for cleaner and competitive alternate power generation system. When the fuel cells are integrated with the Gas Turbines, the total thermal efficiency of the combined cycle is obtained greater than 60%. In this paper, thermodynamic analysis of SOFC-GT combined system (2.898MW has been carried out, exergy efficiency and exergy destruction of each component are calculated.The effect of compression ratio (rp, turbine inlet temperature (TIT and ambient temperature of air, on the performance of the system has been analyzed. Outcome of the system modeling reveals that SOFC andcombustion chamber are the main sources of exergy destruction. At the optimum compression ratio 9, the total thermal efficiency and exergy efficiency are found to be 63.3% and 60.85% respectively.

  6. Model studies for determining whether combined-cycle plants can participate in control of frequency and power flows in unified energy systems of Russia

    Science.gov (United States)

    Davydov, N. I.; Zorchenko, N. V.; Davydov, A. V.; Radin, Yu. A.

    2009-10-01

    Approximating transfer functions of a PGU-39 combined-cycle plant as a technological system with a controlled power output are presented, a structure of a system for automatic closed-loop control of the combined-cycle plant power output is proposed, and results from model investigations of this system are presented.

  7. Development of a dynamic simulator for a natural gas combined cycle (NGCC) power plant with post-combustion carbon capture

    Energy Technology Data Exchange (ETDEWEB)

    Liese, E.; Zitney, S.

    2012-01-01

    The AVESTAR Center located at the U.S. Department of Energy’s National Energy Technology Laboratory and West Virginia University is a world-class research and training environment dedicated to using dynamic process simulation as a tool for advancing the safe, efficient and reliable operation of clean energy plants with CO{sub 2} capture. The AVESTAR Center was launched with a high-fidelity dynamic simulator for an Integrated Gasification Combined Cycle (IGCC) power plant with pre-combustion carbon capture. The IGCC dynamic simulator offers full-scope Operator Training Simulator (OTS) Human Machine Interface (HMI) graphics for realistic, real-time control room operation and is integrated with a 3D virtual Immersive Training Simulator (ITS), thus allowing joint control room and field operator training. The IGCC OTS/ITS solution combines a “gasification with CO{sub 2} capture” process simulator with a “combined cycle” power simulator into a single high-performance dynamic simulation framework. This presentation will describe progress on the development of a natural gas combined cycle (NGCC) dynamic simulator based on the syngas-fired combined cycle portion of AVESTAR’s IGCC dynamic simulator. The 574 MW gross NGCC power plant design consisting of two advanced F-class gas turbines, two heat recovery steam generators (HRSGs), and a steam turbine in a multi-shaft 2x2x1 configuration will be reviewed. Plans for integrating a post-combustion carbon capture system will also be discussed.

  8. Field operation test of Wakamatsu PFBC combined cycle power plant; Wakamatsu PFBC jissho shiken no genkyo

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T. [Center for Coal Utilization, Japan, Tokyo (Japan); Takanishi, K. [Electric Power Development Co. Ltd., Tokyo (Japan)

    1996-09-01

    At the Wakamatsu Coal Utilization Research Center, the verification test was conducted of atmospheric pressure fluidized bed boilers and ultra-high temperature turbines. The Wakamatsu PFBC (pressurized fluidized bed combustion) is a combined cycle power generation system combining steam turbine power generation in which the turbine is driven by steam generated from the fluidized bed boiler installed inside the pressure vessel and gas turbine power generation in which high temperature/pressure exhaust gas is used from the boiler, having a total output of 71 MW. The operation started in fiscal 1995, stopped due to damage of the tube of CTF (ceramic tube filter), and is now continuing after the repair. As a result of the test conducted in fiscal 1995, it was confirmed in the two-stage cyclone test that the diameter of ash particle and cyclone efficiency change by kind of coal and amount of limestone and that by coal kind gas turbine blades show different states of abrasion, indicating greater abrasion when there is much SiO2 in ash. As a result of the continued high load operation of CTF, ash blockade inside the tube occurred and tube damage was generated by thermal shock, etc. 5 figs., 4 tabs.

  9. Performance analysis of a combined cycle gas turbine power plant by using various inlet air cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Rahim, Murad A. [Department of Mechanical Engineering, Gazi University (Turkey)], e-mail: mrahim@gazi.edu.tr

    2011-07-01

    In recent years, the use of gas turbines in combined cycle power plants has increased. Turbine inlet air cooling appears to be the best solution for maximizing both production and efficiency, particularly in a hot climate. The aim of this study is to determine the impact of different air cooling systems on the gas turbine's performance and carbon dioxide emissions. Computer simulations were carried out, using the THERMOFLEX program, on fogging, evaporative cooling, adsorption cooling, and electrical chiller cooling systems as well as on a base case without cooling system. Results showed that inlet air cooling systems are effective in increasing the efficiency of gas turbine power plants. In addition it was found that absorption chillers are the best system for increasing power generation but that economic and source analyses should be conducted before installing a cooling system. This paper demonstrated that inlet air cooling systems have the ability to increase net power generation of gas turbine power plants.

  10. Combined cycle power plant with circulating fluidized bed combustion. Final report; Kombikraftwerk mit zirkulierender Druckwirbelschicht-Feuerung. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-05-01

    In the frame of this study the concept of a combined cycle power plant with circulating fluidized bed combustion was investigated for the application of national brown coal. The aims of this study which is subsidised by the FMTR are the following: - evaluation of the experiences which have been made so far in the frame of developing circulating fluidized bed combustion; - reaching of reliable statements about the process technology, about technical risks as well as about the time frame and the costs; - developing a task for a possible realisation of a 150 MW{sub el}-pilot plant in the new Laender. The present study shows that combined cycle power plants which are fuelled by brown coal can be realised according to the principle of circulating fluidized bed combustion with a plant net efficiency of 45% for a power of 150 MW{sub el} (pilot plant) and a plant net efficiency clearly above 47% for a power of 500 MW{sub el} (reference power plant). The combination of this efficient combined cycle power plant technology with a simple brown coal gasification module, that is integrated into a combustion reactor will almost certainly lead to plant net efficiencies of 50% and more, especially for ZDSWF plants of the second generation. (orig./GL) [Deutsch] Im Rahmen dieser Studie ist fuer den Einsatz einheimischer Braunkohle das Konzept eines Kombikraftwerkes auf der Basis der zirkulierenden Druckwirbelschichtfeuerung untersucht worden. Ziele dieser mit BMFT-Mitteln gefoerderten Studie sind: - die Bewertung der bisher im Rahmen der Entwicklung von Druckwirbelschichtfeuerungen gesammelten Erfahrungen, - die Gewinnung belastbarer Aussagen zum verfahrenstechnischen Konzept, zu technischen Risiken sowie zum Zeit- und Kostenrahmen sowie - die Ausarbeitung einer Aufgabenstellung fuer die moegliche Realisierung einer 150-MW{sub el}-Pilotanlage in den neuen Bundeslaendern. Die vorliegende Studie zeigt, dass mit Braunkohle befeuerte Kombikraftwerksanlagen nach dem Prinzip der

  11. Performance Improvement of Combined Cycle Power Plant Based on the Optimization of the Bottom Cycle and Heat Recuperation

    Institute of Scientific and Technical Information of China (English)

    Wenguo XIANG; Yingying CHEN

    2007-01-01

    Many F class gas turbine combined cycle (GTCC) power plants are built in China at present because of less emission and high efficiency. It is of great interest to investigate the efficiency improvement of GTCC plant. A combined cycle with three-pressure reheat heat recovery steam generator (HRSG) is selected for study in this paper.In order to maximize the GTCC efficiency, the optimization of the HRSG operating parameters is performed. The operating parameters are determined by means of a thermodynamic analysis, i.e. the minimization of exergy losses. The influence of HRSG inlet gas temperature on the steam bottoming cycle efficiency is discussed. The result shows that increasing the HRSG inlet temperature has less improvement to steam cycle efficiency when it is over 590℃. Partial gas to gas recuperation in the topping cycle is studied. Joining HRSG optimization with the use of gas to gas heat recuperation, the combined plant efficiency can rise up to 59.05% at base load. In addition,the part load performance of the GTCC power plant gets much better. The efficiency is increased by 2.11% at 75% load and by 4.17% at 50% load.

  12. Post combustion in combined cycle power plants; La post-combustion nei cicli combinati

    Energy Technology Data Exchange (ETDEWEB)

    Gozzi, M. [comp. (Italy)

    2002-02-01

    Post combustion is a valid aid for combined cycle gas turbine, are evaluated environmental impact and effectiveness. [Italian] La combustione addizionale puo' essere un valido ausilio per i cicli combinati con turbina a gas. I limiti di convenienza. La valutazione dell'impatto ambientale.

  13. Conversion of coal-fired power plants to cogeneration and combined-cycle thermal and economic effectiveness

    CERN Document Server

    Bartnik, Ryszard

    2014-01-01

    This book covers methodology, calculation procedures and tools to support enterprise planning for adapting power stations to cogeneration and combined-cycle forms. It examines the optimum selection of the structure of heat exchangers in a 370 MW power block.

  14. Performance analysis of a bio-gasification based combined cycle power plant employing indirectly heated humid air turbine

    Science.gov (United States)

    Mukherjee, S.; Mondal, P.; Ghosh, S.

    2016-07-01

    Rapid depletion of fossil fuel has forced mankind to look into alternative fuel resources. In this context, biomass based power generation employing gas turbine appears to be a popular choice. Bio-gasification based combined cycle provides a feasible solution as far as grid-independent power generation is concerned for rural electrification projects. Indirectly heated gas turbine cycles are promising alternatives as they avoid downstream gas cleaning systems. Advanced thermodynamic cycles have become an interesting area of study to improve plant efficiency. Water injected system is one of the most attractive options in this field of applications. This paper presents a theoretical model of a biomass gasification based combined cycle that employs an indirectly heated humid air turbine (HAT) in the topping cycle. Maximum overall electrical efficiency is found to be around 41%. Gas turbine specific air consumption by mass is minimum when pressure ratio is 6. The study reveals that, incorporation of the humidification process helps to improve the overall performance of the plant.

  15. Are integrated coal gasification combined-cycle power plants competitive?; Sind Kombi-Kraftwerke mit integrierter Kohlevergasung wettbewerbsfaehig?

    Energy Technology Data Exchange (ETDEWEB)

    Pruschek, R. [Essen Univ. (Gesamthochschule) (Germany); Haupt, G.; Zimmermann, G. [Siemens AG Energieerzeugung KWU, Erlangen (Germany); Ullrich, N. [Krupp Uhde GmbH, Dortmund (Germany)

    1999-08-01

    From investigations into improvements that are feasible already today for integrated coal gasification combined-cycle power plants net plant efficiencies of 51.5% (with reference to the calorifica value), not considering the calorific value of the separated elemental sulfur. Specific investment costs (plant supply price) have been determined with US-dollars 1100/kW. With the given market conditions, assumptions and investigation results the IGCC power plant is in a position to compete with a modern hard coal-fired steam power plant. Detailed investigations show a further efficiency potential of about 56% under consideration of future developments. With SOFC fuel cells upstream of the plant a further increase is conceivable. (orig.) [Deutsch] Aus Untersuchungen von bereits heute durchfuehrbaren Verbesserungen bei Kombi-Kraftwerken mit integrierter Kohlevergasung errechnet sich ein Netto-Anlagenwirkungsgrad von 51,5% (auf den Heizwert bezogen). Dabei ist der Heizwert des in der Entschwefelungsanlage abgetrennten elementaren Schwefels nicht beruecksichtigt. Die spezifische Investition (Anlagenlieferpreis) wurde zu US-Dollar 1100/kW ermittelt. Unter den beschriebenen Marktbedingungen, Annahmen und Untersuchungsergebnissen kann das IGCC-Kraftwerk bei einer Ausnutzungsdauer von 7000 h/a mit einem modernen Steinkohle-Dampfkraftwerk konkurrieren. Detaillierte Untersuchungen zeigen unter Einbeziehung zukuenftiger Entwicklungsschritte ein weiteres Wirkungsgradpotential bis etwa 56%. Mit SOFC-Brennstoffzellen als Vorschaltstufe ist eine weitere Erhoehung denkbar. (orig.)

  16. Parametric-Based Thermodynamic Analysis of Organic Rankine Cycle as Bottoming Cycle for Combined-Cycle Power Plant

    Directory of Open Access Journals (Sweden)

    SAMIULLAH QURESHI

    2017-01-01

    Full Text Available In Pakistan, the thermal efficiency of the power plants is low because of a huge share of fuel energy is dumped into the atmosphere as waste heat. The ORC (Organic Rankine Cycle has been revealed as one of the promising technologies to recover waste heat to enhance the thermal efficiency of the power plant. In current work, ORC is proposed as a second bottoming cycle for existing CCPP (Combined Cycle Power Plant. In order to assess the efficiency of the plant, a thermodynamic model is developed in the ESS (Engineering Equation Solver software. The developed model is used for parametric analysis to assess the effects of various operating parameters on the system performance. The analysis of results shows that the integration of ORC system with existing CCPP system enhances the overall power output in the range of 150.5-154.58 MW with 0.24-5% enhancement in the efficiency depending on the operating conditions. During the parametric analysis of ORC, it is observed that inlet pressure of the turbine shows a significant effect on the performance of the system as compared to other operating parameters.

  17. Selecting the process arrangement for preparing the gas turbine working fluid for an integrated gasification combined-cycle power plant

    Science.gov (United States)

    Ryzhkov, A. F.; Gordeev, S. I.; Bogatova, T. F.

    2015-11-01

    Introduction of a combined-cycle technology based on fuel gasification integrated in the process cycle (commonly known as integrated gasification combined cycle technology) is among avenues of development activities aimed at achieving more efficient operation of coal-fired power units at thermal power plants. The introduction of this technology is presently facing the following difficulties: IGCC installations are characterized by high capital intensity, low energy efficiency, and insufficient reliability and availability indicators. It was revealed from an analysis of literature sources that these drawbacks are typical for the gas turbine working fluid preparation system, the main component of which is a gasification plant. Different methods for improving the gasification plant chemical efficiency were compared, including blast air high-temperature heating, use of industrial oxygen, and a combination of these two methods implying limited use of oxygen and moderate heating of blast air. Calculated investigations aimed at estimating the influence of methods for achieving more efficient air gasification are carried out taking as an example the gasifier produced by the Mitsubishi Heavy Industries (MHI) with a thermal capacity of 500 MW. The investigation procedure was verified against the known experimental data. Modes have been determined in which the use of high-temperature heating of blast air for gasification and cycle air upstream of the gas turbine combustion chamber makes it possible to increase the working fluid preparation system efficiency to a level exceeding the efficiency of the oxygen process performed according to the Shell technology. For the gasification plant's configuration and the GTU working fluid preparation system be selected on a well-grounded basis, this work should be supplemented with technical-economic calculations.

  18. Biomass integrated CFB gasification combined cycle plants

    Energy Technology Data Exchange (ETDEWEB)

    Greil, C.; Hirschfelder, H. (Lurgi Umwelt GmbH, Frankfurt am Main (Germany))

    1998-01-01

    This paper presents an overview on the Lurgi-Circulating Fluidized Bed technology (CFB). CFB units are state of the art and have proven their capability of converting biomass, waste or coal into power and/or steam. CFB reactors are in commercial operation for reduction processes and for combustion and gasification of solid fuels. In this paper reduction processes are not considered. The fact, that world-wide over 80 CFB combustion plants using Lurgi technology are commercially operating proves that this technology is well accepted. Lurgi's CFB gasification technology is at present applied in two industrial plants. It is the key process for the advanced biomass or waste utilisation plants. The paper focuses on CFB fuel gas production for combined cycle plants (IGCC) and for cofiring into existing boiler plants. 5 refs., 4 figs.

  19. Biomass integrated CFB gasification combined cycle plants

    Energy Technology Data Exchange (ETDEWEB)

    Greil, C.; Hirschfelder, H. [Lurgi Umwelt GmbH, Frankfurt am Main (Germany)

    1998-12-31

    This paper presents an overview on the Lurgi-Circulating Fluidized Bed technology (CFB). CFB units are state of the art and have proven their capability of converting biomass, waste or coal into power and/or steam. CFB reactors are in commercial operation for reduction processes and for combustion and gasification of solid fuels. In this paper reduction processes are not considered. The fact, that world-wide over 80 CFB combustion plants using Lurgi technology are commercially operating proves that this technology is well accepted. Lurgi`s CFB gasification technology is at present applied in two industrial plants. It is the key process for the advanced biomass or waste utilisation plants. The paper focuses on CFB fuel gas production for combined cycle plants (IGCC) and for cofiring into existing boiler plants. 5 refs., 4 figs.

  20. The extension of Ubungo power plant in Dar es Salaam, Tanzania, to a combined cycle - A prestudy

    Energy Technology Data Exchange (ETDEWEB)

    Grinneland, L.; Oehrstroem, K.

    1996-05-01

    The report deals with the consequences concerning a future extension of Ubungo Power Plant. Today the power plant consists of four gas turbines, two of model General Electric LM6000 and two of model ABB Stal GT10 of which the latter were the ones focused on. In the report four different applications are presented; Simple two pressure system, Two pressure system with reheat, Two pressure system with heat exchange between feedwater and condensate, and single pressure system with an additional evaporating loop. The calculations are divided into three sections; thermodynamic calculations, calculations of the heat exchanger surface areas, and economic calculations. From the thermodynamic calculations the applications with the highest thermal efficiency was selected. The power output increased with about 55% and the thermal efficiency of the complete combined cycle is 48.2%. This is, of course, a theoretical value calculated without consideration to a number of losses that will decrease both the power output and the thermal efficiency. At part load (50% load assumed, i.e. one gas turbine is operating) the thermal efficiency is 46.7%. The economic calculations indicated that the extension is highly worthwhile in an economic point of view; both cases studied have a payback time of less than six years for full load operation, provided that the charging system which is to be imposed by the World Bank has come into force. 18 refs, 33 figs

  1. Power and Efficiency Analysis of a Solar Central Receiver Combined Cycle Plant with a Small Particle Heat Exchanger Receiver

    Science.gov (United States)

    Virgen, Matthew Miguel

    Two significant goals in solar plant operation are lower cost and higher efficiencies. To achieve those goals, a combined cycle gas turbine (CCGT) system, which uses the hot gas turbine exhaust to produce superheated steam for a bottoming Rankine cycle by way of a heat recovery steam generator (HRSG), is investigated in this work. Building off of a previous gas turbine model created at the Combustion and Solar Energy Laboratory at SDSU, here are added the HRSG and steam turbine model, which had to handle significant change in the mass flow and temperature of air exiting the gas turbine due to varying solar input. A wide range of cases were run to explore options for maximizing both power and efficiency from the proposed CSP CCGT plant. Variable guide vanes (VGVs) were found in the earlier model to be an effective tool in providing operational flexibility to address the variable nature of solar input. Combined cycle efficiencies in the range of 50% were found to result from this plant configuration. However, a combustor inlet temperature (CIT) limit leads to two distinct Modes of operation, with a sharp drop in both plant efficiency and power occurring when the air flow through the receiver exceeded the CIT limit. This drawback can be partially addressed through strategic use of the VGVs. Since system response is fully established for the relevant range of solar input and variable guide vane angles, the System Advisor Model (SAM) from NREL can be used to find what the actual expected solar input would be over the course of the day, and plan accordingly. While the SAM software is not yet equipped to model a Brayton cycle cavity receiver, appropriate approximations were made in order to produce a suitable heliostat field to fit this system. Since the SPHER uses carbon nano-particles as the solar absorbers, questions of particle longevity and how the particles might affect the flame behavior in the combustor were addressed using the chemical kinetics software Chemkin

  2. Vuosaari B, the largest combined cycle power plant in the Nordic Countries. Vuosaari B Pohjoismaiden suurin kombivoimalaitos

    Energy Technology Data Exchange (ETDEWEB)

    Tuominen, J. (Ahlstroem Thermoflow, Varkaus (Finland))

    1994-01-01

    The plant concept is so called gas turbine combined cycle power plant. The natural gas fueled gas turbines produce electric power in total 320 MW. The energy of the flue gases of the gas turbines is recovered using heat recovery boilers, and the steam produced by them is used at 140 MW[sub e] back-pressure steam turbine. In addition to the electric power about 410 MW of district heat is generated. The gas turbines will be equipped with Dry-LowNo[sub x] combustion chambers so the emissions of the plant will be lower than the limits required by the authorities. Both heat recovery boilers have been combined parallel, and both of them will produce 75 bar steam and at the 7.5 bar pressure level the amount of high-pressure steam is 68 kg/s and that of the low-pressure steam 14.0 kg/s. The intermediate tapping steam will be led into the district heat exchanger, there the energy content of it will transferred into the district heating water. The boilers are under supported natural circulation boilers, in which the gas flows horizontally through the boiler. The steam generators of the boilers are also based on natural circulation. The heat exchanger packages of the boiler are made of curved finned tube supported by the sliding posts to the base of the boiler room. The steel smoke pipes are also supported directly on the base so the wind load on the pipes can be passed while dimensioning the steel construction of the boiler room. All the heat delivery surfaces of the boiler have modular construction

  3. Steady-state simulation and optimization of an integrated gasification combined cycle power plant with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, D.; Turton, R.; Zitney, S.

    2011-01-01

    Integrated gasification combined cycle (IGCC) plants are a promising technology option for power generation with carbon dioxide (CO2) capture in view of their efficiency and environmental advantages over conventional coal utilization technologies. This paper presents a three-phase, top-down, optimization-based approach for designing an IGCC plant with precombustion CO2 capture in a process simulator environment. In the first design phase, important global design decisions are made on the basis of plant-wide optimization studies with the aim of increasing IGCC thermal efficiency and thereby making better use of coal resources and reducing CO2 emissions. For the design of an IGCC plant with 90% CO2 capture, the optimal combination of the extent of carbon monoxide (CO) conversion in the water-gas shift (WGS) reactors and the extent of CO2 capture in the SELEXOL process, using dimethylether of polyethylene glycol as the solvent, is determined in the first phase. In the second design phase, the impact of local design decisions is explored considering the optimum values of the decision variables from the first phase as additional constraints. Two decisions are made focusing on the SELEXOL and Claus unit. In the third design phase, the operating conditions are optimized considering the optimum values of the decision variables from the first and second phases as additional constraints. The operational flexibility of the plant must be taken into account before taking final design decisions. Two studies on the operational flexibility of the WGS reactors and one study focusing on the operational flexibility of the sour water stripper (SWS) are presented. At the end of the first iteration, after executing all the phases once, the net plant efficiency (HHV basis) increases to 34.1% compared to 32.5% in a previously published study (DOE/NETL-2007/1281; National Energy Technology Laboratory, 2007). The study shows that the three-phase, top-down design approach presented is very

  4. Identification of hazards in non-nuclear power plants. [Public health hazards of fossil-fuel, combined cycle, combustion turbine, and geothermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Roman, W.S.; Israel, W.J.; Sacramo, R.F.

    1978-07-01

    Public health and safety hazards have been identified for five types of power plants: coal-fired, oil-fired steam turbine, combined cycle, combustion (gas) turbine, and geothermal. The results of the analysis show that air pollutants are the major hazard that affects the health and safety of the general public. A total of ninety plant hazards were identified for the five plant types. Each of these hazards were rated in six categories as to their affect on the general public. The criteria used in the analysis were: area/population exposed; duration; mitigation; quantity to toxicity ratio; nature of health effects; and public attitude. Even though ninety hazards were identified for the five plants analyzed, the large majority of hazards were similar for each plant. Highest ratings were given to the products of the combustion cycle or to hydrogen sulfide emissions from geothermal plants. Water pollution, cooling tower effects and noise received relatively low ratings. The highest rated of the infrequent or hypothetical hazards were those associated with potential fires, explosions, and chlorine releases at the plant. Hazards associated with major cooling water releases, water pollution and missiles received the lowest ratings. Since the results of the study clearly show that air pollutants are currently considered the most severe hazard, additional effort must be made to further understand the complex interactions of pollutants with man and his environment. Of particular importance is the determination of dose-response relationships for long term, low level exposure to air pollutants. (EDB)

  5. Gasification combined cycle power generation - process alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Kurkela, E.; Korhonen, M.

    1988-01-01

    Interest in Integrated Gasification Combined Cycle (IGCC) power plants has recently increased also in Finland. The IGCC systems offer the potential of superior efficiency and environmental performance over conventional pulverized coal or peat fired boilers. Potential applications are both large-scale electricity production from coal and medium-scale combined heat and electricity production. In the latter case, the gasification process should also be applicable to peat and wood. Several IGCC processes have been developed in USA and in Europe. These processes differ from each other in many respects. Nearest to commercialization are processes, which employ oxygen gasification and cold gas cleanup. The Cool Water plant, which was brought into operation in 1984 in USA, has demonstrated the feasibility of an IGCC system using Texaco entrained-bed gasifier. Several pressurized fluidized-bed and fixed-bed gasification processes have also reached a pilot or demonstration stage with a wide variety of coals from lignite to hard coal. Pressurized fluidized-bed gasification of peat (Rheinbraun-HTW-process) will also be demonstrated at the peat ammonia plant of Kemira Oy, which will be commissioned in 1988 in Oulu, Finland. Oxygen gasification and cold gas cleanup are, however, economically viable only in large-scale applications. Technology is being developed to simplify the IGCC system, in order to reduce its capital costs and increase its efficiency. Air gasification combined with ho gas cleanup seems to have a great potential of improving the competitiveness of the IGCC system.

  6. Joule II - programme. Clean coal technology R & D; 2nd phase. Volume V. Enhancement of the efficiency of integrated gasification combined cycle (IGCC) power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hein, K.R.G.; Minchener, A.J.; Pruschek, R.; Roberts, P.A. [eds.

    1998-12-31

    Methods of enhancing the efficiency of integrated gasification combined cycle (IGCC) power plants were investigated under the JOULE II extension project JOU2-CT94-0454. These included thermodynamic analysis of measures for efficiency enhancement, and development and design of advanced heat recovery steam generator. All 3 papers have been abstracted separately.

  7. Experimental results of ammonia operated condensate polishing plants in combined cycle power plants; Untersuchungsergebnisse zur Ammoniumfahrweise einer Kondensatreinigungsanlage bei GuD-Kraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Ochsmann, Christian [Erlangen-Nuernberg Univ., Erlangen (Germany); Jahr, Henrik; Glueck, Wolfgang [Siemens AG, Erlangen (Germany); Neumann, Stefan; Wedemeyer, Hans-Juergen [Lanxess Deutschland GmbH, Leverkusen (Germany)

    2013-04-01

    Modern combined cycle power plants with once-through boilers require highly pure boiler feedwater. Typically a condensate polishing plant (CPP) is used as 'salt sink' in the water-steam cycle, with a combination of cation and anion exchanger resin in a mixed bed filter. Ammonia ions are removed which reduces the lifetime of CPP. An alternative is the so-called 'ammonium form operation' which is being presented and discussed. This mode was investigated. The experimental results show that the 'ammonium form operation' is an attractive technology, which offers reduced operating costs and therefore meets economical expectations of power plant operators. (orig.)

  8. Chasing megawatts in combined cycle plants

    Energy Technology Data Exchange (ETDEWEB)

    Koch, J. [Power Plant Performance Specialist, Lansdowne, PA (United States); DeGeeter, S. [Ocean State Power, Harrisville, RI (United States); Haynes, C.J. [New England Power Co., Somerset, MA (United States)

    1996-05-01

    Combined cycle owners do not have to accept that combined cycle performance must degrade over time. Through low cost testing using existing instrumentation, a method is presented to identify causes for lost generation. A 500 MW combined cycle plant, with two STAG 207EA units, had lost 17 MW since initial operation, and found that: Gas side fouling on A four HRSG`s accounted for 8 MW of the total loss LP steam turbine efficiency was below design on one unit, contributing 3 MW Condenser air removal was poor on both units, a loss of an additional 2 MW Compressor and turbine section efficiency losses on 2 of 4 GT`s cost over 4 MW The test also revealed that the other two GT`s, both cooling towers, and one of the two steam turbines, were performing at or near design. Thus far 3 MW has been recovered, with planning underway for recovery of another 3 MW. The remaining 11 MW, though not immediately recoverable, will be the focus of planning for the next major outage. This simple method can be used at any combined cycle using existing instrumentation, with minimal intrusion on daily operations. The use of redundant measurements and uncertainty analysis assures valid and useful results.

  9. The effectiveness of using the combined-cycle technology in a nuclear power plant unit equipped with an SVBR-100 reactor

    Science.gov (United States)

    Kasilov, V. F.; Dudolin, A. A.; Gospodchenkov, I. V.

    2015-05-01

    The design of a modular SVBR-100 reactor with a lead-bismuth alloy liquid-metal coolant is described. The basic thermal circuit of a power unit built around the SVBR-100 reactor is presented together with the results of its calculation. The gross electrical efficiency of the turbine unit driven by saturated steam at a pressure of 6.7 MPa is estimated at η{el/gr} = 35.5%. Ways for improving the efficiency of this power unit and increasing its power output by applying gas-turbine and combined-cycle technologies are considered. With implementing a combined-cycle power-generating system comprising two GE-6101FA gas-turbine units with a total capacity of 140 MW, it becomes possible to obtain the efficiency of the combined-cycle plant equipped with the SVBR-100 reactor η{el/gr} = 45.39% and its electrical power output equal to 328 MW. The heat-recovery boiler used as part of this power installation generates superheated steam with a temperature of 560°C, due to which there is no need to use a moisture separator/steam reheater in the turbine unit thermal circuit.

  10. System study of an MHD/gas turbine combined-cycle baseload power plant. HTGL report No. 134

    Energy Technology Data Exchange (ETDEWEB)

    Annen, K.D.

    1981-08-01

    The MHD/gas turbine combined-cycle system has been designed specifically for applications where the availability of cooling water is very limited. The base case systems which were studied consisted of an MHD plant with a gas turbine bottoming plant, and required no cooling water. The gas turbine plant uses only air as its working fluid and receives its energy input from the MHD exhaust gases by means of metal tube heat exchangers. In addition to the base case systems, vapor cycle variation systems were considered which included the addition of a vapor cycle bottoming plant to improve the thermal efficiency. These systems required a small amount of cooling water. The MHD/gas turbine systems were modeled with sufficient detail, using realistic component specifications and costs, so that the thermal and economic performance of the system could be accurately determined. Three cases of MHD/gas turbine systems were studied, with Case I being similar to an MHD/steam system so that a direct comparison of the performances could be made, with Case II being representative of a second generation MHD system, and with Case III considering oxygen enrichment for early commercial applications. The systems are nominally 800 MW/sub e/ to 1000 MW/sub e/ in size. The results show that the MHD/gas turbine system has very good thermal and economic performances while requiring either little or no cooling water. Compared to the MHD/steam system which has a cooling tower heat load of 720 MW, the Base Case I MHD/gas turbine system has a heat rate which is 13% higher and a cost of electricity which is only 7% higher while requiring no cooling water. Case II results show that an improved performance can be expected from second generation MHD/gas turbine systems. Case III results show that an oxygen enriched MHD/gas turbine system may be attractive for early commercial applications in dry regions of the country.

  11. Recovery, transport, and disposal of CO{sub 2} from an integrated gasification combined-cycle power plant

    Energy Technology Data Exchange (ETDEWEB)

    Livengood, C.D.; Doctor, R.D.; Molburg, J.C.; Thimmapuram, P.; Berry, G.F.

    1993-12-31

    Initiatives to limit CO{sub 2} emissions have drawn considerable interest to integrated gasification combined-cycle (IGCC) power generation, a process that reduces CO{sub 2} production and is amenable to CO{sub 2} capture. This paper presents a comparison of energy systems that encompass fuel supply, an IGCC system, CO{sub 2} recovery using commercial technologies, CO{sub 2} transport by pipeline, and land-based sequestering in geological reservoirs. The intent is to evaluate the energy efficiency impacts of controlling CO{sub 2} in such a system, and to provide the CO{sub 2} budget, or an equivalent CO{sub 2} budget, associated with each of the individual energy-cycle steps. The value used for the equivalent CO{sub 2} budget is 1 kg CO{sub 2}/kWh. The base case for the comparison is a 458-MW IGCC system using an air-blown Kellogg Rust Westinghouse (KRW) agglomerating fluidized-bed gasifier, Illinois No.6 bituminous coal, and in-bed sulfur removal. Mining, transportation, and preparation of the coal and limestone result in a net electric power production of 448 MW with a 0.872 kg/kWh CO{sub 2} release rate. For comparison, the gasifier output was taken through a water-gas shift to convert CO to CO{sub 2}, and processed in a Selexol unit to recover CO{sub 2} prior to the combustion turbine. A 500-km pipeline then took the CO{sub 2} to geological sequestering. The net electric power production was 383 MW with a 0.218 kg/kWh CO{sub 2} release rate.

  12. Alternative analysis to increase the power in combined-cycle power plants; Analisis de alternativas para el incremento de potencia en plantas termoelectricas de Ciclo Combinado

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco Cruz, Hector; Arriola Medellin, Alejandro M. [Gerencia de Procesos Termicos, Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: hpacheco@iie.org.mx; aarriola@iie.org.mx

    2010-11-15

    The electricity industry traditionally had two thermodynamic cycles for power generation: conventional steam turbine (Rankine cycle) used to supply a base load during the day, and gas turbines (Brayton cycle), for its speed response, normally used to cover peak loads. However, to provide variable peak loads, the gas turbine, as a volumetric machine is affected by the change in air density by changing the combustion temperature. This paper shows the scheme of integration of both systems, that it's known as combined cycle and the different options that would have these power plants, to maintain or increase their power in variable ambient conditions. It analyzes different options, such as: 1. Supplementary fire in the stove. 2. Air cooling intake in the gas turbine (evaporation system or mechanical system). 3. Steam injection in the combustion chamber. [Spanish] La industria electrica tradicionalmente a contado con dos ciclos termodinamicos para generacion electrica: las turbinas convencionales de vapor (ciclo de Rankine) se utilizan para suministrar una carga base durante el dia, y las turbinas de gas (ciclo de Brayton), por su rapidez de respuesta, se utilizan normalmente para cubrir las cargas pico. Sin embargo, para suministrar las cargas variables pico, la turbina a gas, por ser una maquina volumetrica, se ve afectada por el cambio de la densidad del aire de combustion al cambiar la temperatura ambiente. En este trabajo se muestra el esquema de integracion de ambos sistemas, en lo que se conoce como ciclo combinado y las diferentes opciones que tendrian estas plantas de generacion electrica para mantener o incrementar su potencia en condiciones ambiente variable. Para ello se analizan diferentes opciones, tales como: 1.- Combustion suplementaria en el recuperador de calor. 2.- Enfriamiento del aire de admision a la turbina de gas (mediante un sistema de evaporacion o mediante un sistema mecanico). 3.- Inyeccion de vapor a la camara de combustion. Palabras

  13. Dynamic Modeling and Plantwide Control of a Hybrid Power and Chemical Plant: An Integrated Gasification Combined Cycle Coupled with a Methanol Plant

    Science.gov (United States)

    Robinson, Patrick J.

    Gasification has been used in industry on a relatively limited scale for many years, but it is emerging as the premier unit operation in the energy and chemical industries. The switch from expensive and insecure petroleum to solid hydrocarbon sources (coal and biomass) is occurring due to the vast amount of domestic solid resources, national security and global warming issues. Gasification (or partial oxidation) is a vital component of "clean coal" technology. Sulfur and nitrogen emissions can be reduced, overall energy efficiency is increased and carbon dioxide recovery and sequestration are facilitated. Gasification units in an electric power generation plant produce a fuel gas for driving combustion turbines. Gasification units in a chemical plant generate synthesis gas, which can be used to produce a wide spectrum of chemical products. Future plants are predicted to be hybrid power/chemical plants with gasification as the key unit operation. The coupling of an Integrated Gasification Combined Cycle (IGCC) with a methanol plant can handle swings in power demand by diverting hydrogen gas from a combustion turbine and synthesis gas from the gasifier to a methanol plant for the production of an easily-stored, hydrogen-consuming liquid product. An additional control degree of freedom is provided with this hybrid plant, fundamentally improving the controllability of the process. The idea is to base-load the gasifier and use the more responsive gas-phase units to handle disturbances. During the summer days, power demand can fluctuate up to 50% over a 12-hour period. The winter provides a different problem where spikes of power demand can go up 15% within the hour. The following dissertation develops a hybrid IGCC / methanol plant model, validates the steady-state results with a National Energy Technical Laboratory study, and tests a proposed control structure to handle these significant disturbances. All modeling was performed in the widely used chemical process

  14. Energy and exergy analyses of an integrated gasification combined cycle power plant with CO2 capture using hot potassium carbonate solvent.

    Science.gov (United States)

    Li, Sheng; Jin, Hongguang; Gao, Lin; Mumford, Kathryn Anne; Smith, Kathryn; Stevens, Geoff

    2014-12-16

    Energy and exergy analyses were studied for an integrated gasification combined cycle (IGCC) power plant with CO2 capture using hot potassium carbonate solvent. The study focused on the combined impact of the CO conversion ratio in the water gas shift (WGS) unit and CO2 recovery rate on component exergy destruction, plant efficiency, and energy penalty for CO2 capture. A theoretical limit for the minimal efficiency penalty for CO2 capture was also provided. It was found that total plant exergy destruction increased almost linearly with CO2 recovery rate and CO conversion ratio at low CO conversion ratios, but the exergy destruction from the WGS unit and the whole plant increased sharply when the CO conversion ratio was higher than 98.5% at the design WGS conditions, leading to a significant decrease in plant efficiency and increase in efficiency penalty for CO2 capture. When carbon capture rate was over around 70%, via a combination of around 100% CO2 recovery rate and lower CO conversion ratios, the efficiency penalty for CO2 capture was reduced. The minimal efficiency penalty for CO2 capture was estimated to be around 5.0 percentage points at design conditions in an IGCC plant with 90% carbon capture. Unlike the traditional aim of 100% CO conversion, it was recommended that extremely high CO conversion ratios should not be considered in order to decrease the energy penalty for CO2 capture and increase plant efficiency.

  15. Performance study of a combined cycle power plant with integral gasification; Estudio del desempeno de una planta de potencia de ciclo combinado con gasificacion integral

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Rocha, Jose Clemente

    2007-04-15

    At world-wide level, in the last decade the interest has been increased in the use of petroleum coke as fuel in the clean generation of energy applying the gasification technology. This interest is mainly due to the increment the production of petroleum coke as a result of processing larger volumes of crude processed in the refineries and to the increment in the yield of products with high added value, such as turbo-fuel or diesel, among others. With the new reconfiguration of the Mexican refinery of Cd. Madero and Cadereyta and soon with the completion of the reconfiguration of the Minatitlan, Veracruz refinery, larger amounts of coke will be produced, with the possibility of using it, by means of the appropriate gasification technology, to produce a clean synthetic gas (gasl) with the appropriate energy characteristic to be used as fuel in a combined cycle existing in Mexico. In Mexico the possibilities of generation of electrical energy from the utilization of petroleum coke have been considered departing from the use of petroleum coke using the gasification technology or using fluidized bed steam generators as is the case of the power plant TEG in Taquin, San Luis Potosi. Such is the fact, that at the moment PEMEX Refinacion, has completed the project of constructing in Tuxpan, Veracruz a crude processing refinery of Mayan crude with a high sulfur content and next to the Tuxpan Power Plant, being contemplated the possibility of applying the concept of combined cycle with integrated gasification (CCGI); with this infrastructure it will be possible to consume the coke generated by the Mexican refineries. The expected electrical generation is of 500 MW, of which 100 MW will be for own consumption of the refinery and 400 MW free to cover the electrical energy demand within the North East and Center Zone of the country. The petroleum coke derived from the refineries of the country can be used for the clean generation of electricity by means of its gasification and

  16. Recovery of flue gas energy in heat-integrated gasification combined cycle (IGCC) power plants using the contact economizer system

    CSIR Research Space (South Africa)

    Madzivhandila, VA

    2011-03-01

    Full Text Available temperature. Recovery of the flue gas heat to preheat the boiler feedwater was demonstrated to be capable of further increasing the thermal efficiency of the plant. The methodology developed is divided into two parts, i.e., determining the maximum boiler...

  17. Development of Natural Gas Fired Combined Cycle Plant for Tri-Generation of Power, Cooling and Clean Water Using Waste Heat Recovery: Techno-Economic Analysis

    Directory of Open Access Journals (Sweden)

    Gowtham Mohan

    2014-10-01

    Full Text Available Tri-generation is one of the most efficient ways for maximizing the utilization of available energy. Utilization of waste heat (flue gases liberated by the Al-Hamra gas turbine power plant is analyzed in this research work for simultaneous production of: (a electricity by combining steam rankine cycle using heat recovery steam generator (HRSG; (b clean water by air gap membrane distillation (AGMD plant; and (c cooling by single stage vapor absorption chiller (VAC. The flue gases liberated from the gas turbine power cycle is the prime source of energy for the tri-generation system. The heat recovered from condenser of steam cycle and excess heat available at the flue gases are utilized to drive cooling and desalination cycles which are optimized based on the cooling energy demands of the villas. Economic and environmental benefits of the tri-generation system in terms of cost savings and reduction in carbon emissions were analyzed. Energy efficiency of about 82%–85% is achieved by the tri-generation system compared to 50%–52% for combined cycles. Normalized carbon dioxide emission per MW·h is reduced by 51.5% by implementation of waste heat recovery tri-generation system. The tri-generation system has a payback period of 1.38 years with cumulative net present value of $66 million over the project life time.

  18. Combined Cycle Power Generation Employing Pressure Gain Combustion

    Energy Technology Data Exchange (ETDEWEB)

    Holley, Adam [United Technologies Corporation, East Hartford, CT (United States). Research Center

    2017-05-15

    The Phase I program assessed the potential benefit of applying pressure gain combustion (PGC) technology to a natural gas combined cycle power plant. A conceptual design of the PGC integrated gas turbine was generated which was simulated in a detailed system modeling tool. The PGC integrated system was 1.93% more efficient, produced 3.09% more power, and reduced COE by 0.58%. Since the PGC system used had the same fuel flow rate as the baseline system, it also reduced CO2 emissions by 3.09%. The PGC system did produce more NOx than standard systems, but even with the performanceand cost penalties associated with the cleanup system it is better in every measure. This technology benefits all of DOE’s stated program goals to improve plant efficiency, reduce CO2 production, and reduce COE.

  19. Combined cycle power plant technology: efficient generation of electrical power with a variety of fuels. Pt. 1; Die Gas- und Dampfturbinen (GuD)-Kraftwerks-Technologie: effiziente Stromerzeugung aus unterschiedlichen Energietraegern. T. 1

    Energy Technology Data Exchange (ETDEWEB)

    Gudenau, H.W. [Inst. fuer Eisenhuettenkunde, Rheinisch-Westfaelische Technische Hochschule Aachen (Germany); Dornbusch, H. [Inst. fuer Eisenhuettenkunde, Rheinisch-Westfaelische Technische Hochschule Aachen (Germany); Hahn, W. [Inst. fuer Eisenhuettenkunde, Rheinisch-Westfaelische Technische Hochschule Aachen (Germany); Hoberg, H. [Inst. fuer Eisenhuettenkunde, Rheinisch-Westfaelische Technische Hochschule Aachen (Germany); Mayerhofer, A. [Inst. fuer Eisenhuettenkunde, Rheinisch-Westfaelische Technische Hochschule Aachen (Germany); Meimeth, S. [Inst. fuer Eisenhuettenkunde, Rheinisch-Westfaelische Technische Hochschule Aachen (Germany); Scharpff, T. [Inst. fuer Eisenhuettenkunde, Rheinisch-Westfaelische Technische Hochschule Aachen (Germany)

    1992-12-01

    About 80% of electrical power generated worldwide is produced in steam turbine power plants fired with fossil fuels. More and more, factors like protection of ressources and environmental aspects are employed. Together with the principally higher efficiency of the combined cycle technology the use of hot coal gas, new fuels (bio-mass) and by-product gases (hot combustion gases, steel mill gases) shall reduce environmental pollution. In part 1 of this two-parted publication, an overview on combined cycle power plant technology is given. Various firing methods and their theoretical efficiencies are discussed. Different hot gas cleaning devices are compared. The stage of development of a hot gas washer working at temperatures above 1300 C is described. Part 2 is occupied with the production of burning gases (gasification of solid and liquid fuels) and the use of industrial by-product gases (steel plant gases) in combined cycle power plant. (orig.) [Deutsch] Im ersten Teil dieser zweiteiligen Veroeffentlichung wird die GuD-Kraftwerkstechnologie vorgestellt und verschiedene Feuerungsmoeglichkeiten anhand der Anforderungen an das Einsatzgas und des theoretisch erreichbaren Wirkungsgrades bewertet. Verschiedene Heissgasreinigungskonzepte werden verglichen. Dargestellt wird der Entwicklungsstand eines oberhalb 1300 C arbeitenden Heissgaswaschverfahrens. Der zweite Teil beschaeftigt sich mit der Erzeugung von Brenngasen (HTWVergasung fester und fluessiger Kohlenstofftraeger), der Verwertung industrieller brennbarer Abgase (Huettengase) und deren Nutzbarmachung fuer den GuD-Prozess. (orig.)

  20. Sensor placement algorithm development to maximize the efficiency of acid gas removal unit for integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture

    Energy Technology Data Exchange (ETDEWEB)

    Paul, P.; Bhattacharyya, D.; Turton, R.; Zitney, S.

    2012-01-01

    Future integrated gasification combined cycle (IGCC) power plants with CO{sub 2} capture will face stricter operational and environmental constraints. Accurate values of relevant states/outputs/disturbances are needed to satisfy these constraints and to maximize the operational efficiency. Unfortunately, a number of these process variables cannot be measured while a number of them can be measured, but have low precision, reliability, or signal-to-noise ratio. In this work, a sensor placement (SP) algorithm is developed for optimal selection of sensor location, number, and type that can maximize the plant efficiency and result in a desired precision of the relevant measured/unmeasured states. In this work, an SP algorithm is developed for an selective, dual-stage Selexol-based acid gas removal (AGR) unit for an IGCC plant with pre-combustion CO{sub 2} capture. A comprehensive nonlinear dynamic model of the AGR unit is developed in Aspen Plus Dynamics® (APD) and used to generate a linear state-space model that is used in the SP algorithm. The SP algorithm is developed with the assumption that an optimal Kalman filter will be implemented in the plant for state and disturbance estimation. The algorithm is developed assuming steady-state Kalman filtering and steady-state operation of the plant. The control system is considered to operate based on the estimated states and thereby, captures the effects of the SP algorithm on the overall plant efficiency. The optimization problem is solved by Genetic Algorithm (GA) considering both linear and nonlinear equality and inequality constraints. Due to the very large number of candidate sets available for sensor placement and because of the long time that it takes to solve the constrained optimization problem that includes more than 1000 states, solution of this problem is computationally expensive. For reducing the computation time, parallel computing is performed using the Distributed Computing Server (DCS®) and the Parallel

  1. Dynamic simulation and load-following control of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, D,; Turton, R.; Zitney, S.

    2012-01-01

    Load-following control of future integrated gasification combined cycle (IGCC) plants with pre-combustion CO{sub 2} capture is expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. To study control performance during load following, a plant-wide dynamic simulation of a coal-fed IGCC plant with CO{sub 2} capture has been developed. The slurry-fed gasifier is a single-stage, downward-fired, oxygen-blown, entrained-flow type with a radiant syngas cooler (RSC). The syngas from the outlet of the RSC goes to a scrubber followed by a two-stage sour shift process with inter-stage cooling. The acid gas removal (AGR) process is a dual-stage physical solvent-based process for selective removal of H{sub 2}S in the first stage and CO{sub 2} in the second stage. Sulfur is recovered using a Claus unit with tail gas recycle to the AGR. The recovered CO{sub 2} is compressed by a split-shaft multistage compressor and sent for sequestration after being treated in an absorber with triethylene glycol for dehydration. The clean syngas is sent to two advanced “F”-class gas turbines (GTs) partially integrated with an elevated-pressure air separation unit. A subcritical steam cycle is used for heat recovery steam generation. A treatment unit for the sour water strips off the acid gases for utilization in the Claus unit. The steady-state model developed in Aspen Plus® is converted to an Aspen Plus Dynamics® simulation and integrated with MATLAB® for control studies. The results from the plant-wide dynamic model are compared qualitatively with the data from a commercial plant having different configuration, operating condition, and feed quality than what has been considered in this work. For load-following control, the GT-lead with gasifier-follow control strategy is considered. A modified proportional–integral–derivative (PID) control is considered for the syngas

  2. Life cycle assessment and evaluation of sustainable product design strategies for combined cycle power plants; Lebenszyklusanalyse und Bestimmung von Einflussfaktoren zur nachhaltigen Produktgestaltung von GuD-Kraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Parthey, Falko

    2010-03-26

    The growth of the national GDP on a worldwide level and the associated increasing demand for primary energy inevitably result in higher emissions levels. According to recent international scientific studies the energy sector (including electricity generation, industrial activities and traffic) contributes up to 83 % to the worldwide greenhouse gas emissions. Climate change and the projection of its impacts have been acknowledged also on the political level and concise measures are being considered. Since access to electricity and sustainable development are inseparable, the question arises whether and how adequate answers can be given within the coming years. Furthermore, the definite lifetime of the existing power plant fleet will result in a gap of up to 12.000 MWh in 2020, depending on the scenario. One part of the answer lies in the sustainable design of power plants. The main contribu-tion of this work is therefore the life cycle analysis of a combined cycle power plant from of a manufacturer's perspective. The visualisation of the entire product system and the re-sults of the impact assessment facilitate the determination of improvement potential. The system boundaries for this study include all relevant phases of the product life cycle (materials, manufacturing, transport, operation, service and end of life). The life cycle inventory consists of all bills of materials and energy consumption for all components and life cycle phases. The interpretation of the results of the impact assessment showed the expected significant contribution in kg CO{sub 2}e for the emission of the full load operation. Nevertheless, the results for all impact categories over the entire lifecycle are given. Various operation scenarios and configurations can now be analysed based on the elaborated modules, and can now serve as decision support already during product development. The visualisation of impacts of design decisions on the ecological footprint of the product system in

  3. All-regime combined-cycle plant: Engineering solutions

    Science.gov (United States)

    Berezinets, P. A.; Tumanovskii, G. G.; Tereshina, G. E.; Krylova, I. N.; Markina, V. N.; Migun, E. N.

    2016-12-01

    The development of distributed power generation systems as a supplement to the centralized unified power grid increases the operational stability and efficiency of the entire power generation industry and improves the power supply to consumers. An all-regime cogeneration combined-cycle plant with a power of 20-25 mW (PGU-20/25T) and an electrical efficiency above 50% has been developed at the All-Russia Thermal Engineering Institute (ATEI) as a distributed power generation object. The PGU-20/25T two-circuit cogeneration plant provides a wide electrical and thermal power adjustment range and the absence of the mutual effect of electrical and thermal power output regimes at controlled frequency and power in a unified or isolated grid. The PGU-20/25T combined-cycle plant incorporates a gas-turbine unit (GTU) with a power of 16 MW, a heat recovery boiler (HRB) with two burners (before the boiler and the last heating stage), and a cogeneration steam turbine with a power of 6/9 MW. The PGU-20/25T plant has a maximum electrical power of 22 MW and an efficiency of 50.8% in the heat recovery regime and a maximum thermal power output of 16.3 MW (14 Gcal/h) in the cogeneration regime. The use of burners can increase the electrical power to 25 MW in the steam condensation regime at an efficiency of 49% and the maximum thermal power output to 29.5 MW (25.4 Gcal/h). When the steam turbine is shut down, the thermal power output can grow to 32.6 MW (28 Gcal/h). The innovative equipment, which was specially developed for PGU-20/25T, improves the reliability of this plant and simplifies its operation. Among this equipment are microflame burners in the heat recovery boiler, a vacuum system based on liquid-ring pumps, and a vacuum deaerator. To enable the application of PGU-20/25T in water-stressed regions, an air condenser preventing the heat-transfer tubes from the risk of covering with ice during operation in frost air has been developed. The vacuum system eliminates the need for

  4. Modeling and optimization of a modified claus process as part of an integrted gasification combined cycle (IGCC) power plant with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.; Bhattacharyya, D.; Turton, R.; Zitney, S.

    2011-01-01

    The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Due to these criteria, modifications are often required to the conventional process, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO2 capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant such as rapid change in the feed flowrates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus furnace, a four-stage method was

  5. Rigorous Kinetic Modeling, Optimization, and Operability Studies of a Modified Claus Unit for an Integrated Gasification Combined Cycle (IGCC) Power Plant with CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Dustin; Bhattacharyya, Debangsu; Turton, Richard; Zitney, Stephen E

    2011-12-15

    The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and the ability to recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Because of these criteria, modifications to the conventional process are often required, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO{sub 2} capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant, such as rapid change in the feed flow rates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but they are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified, and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus

  6. Rigorous Kinetic Modeling and Optimization Study of a Modified Claus Unit for an Integrated Gasification Combined Cycle (IGCC) Power Plant with CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Dustin; Bhattacharyya, Debangsu; Turton, Richard; Zitney, Stephen E.

    2012-02-08

    The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and the ability to recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Because of these criteria, modifications to the conventional process are often required, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO{sub 2} capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant, such as rapid change in the feed flow rates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but they are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified, and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus

  7. Combined cycle plants: Yesterday, today, and tomorrow (review)

    Science.gov (United States)

    Ol'khovskii, G. G.

    2016-07-01

    Gas turbine plants (GTP) for a long time have been developed by means of increasing the initial gas temperature and improvement of the turbo-machines aerodynamics and the efficiency of the critical components air cooling within the framework of a simple thermodynamic cycle. The application of watercooling systems that were used in experimental turbines and studied approximately 50 years ago revealed the fundamental difficulties that prevented the practical implementation of such systems in the industrial GTPs. The steam cooling researches have developed more substantially. The 300 MW power GTPs with a closedloop steam cooling, connected in parallel with the intermediate steam heating line in the steam cycle of the combined cycle plant (CCP) have been built, tested, and put into operation. The designs and cycle arrangements of such GTPs and entire combined cycle steam plants have become substantially more complicated without significant economic benefits. As a result, the steam cooling of gas turbines has not become widespread. The cycles—complicated by the intermediate air cooling under compression and reheat of the combustion products under expansion and their heat recovery to raise the combustion chamber entry temperature of the air—were used, in particular, in the domestic power GTPs with a moderate (700-800°C) initial gas turbine entry temperature. At the temperatures being reached to date (1300-1450°C), only one company, Alstom, applies in their 240-300 MW GTPs the recycled fuel cycle under expansion of gases in the turbine. Although these GTPs are reliable, there are no significant advantages in terms of their economy. To make a forecast of the further improvement of power GTPs, a brief review and assessment of the water cooling and steam cooling of hot components and complication of the GTP cycle by the recycling of fuel under expansion of gases in the turbine has been made. It is quite likely in the long term to reach the efficiency for the

  8. Generating power at high efficiency: combined cycle technology for sustainable energy production

    Energy Technology Data Exchange (ETDEWEB)

    Jeffs, E.

    2008-04-15

    The book reviews key developments in combined cycle technology; gives examples of plants around the world; and looks at how combined cycle technology can evolve to meet future energy needs. Contents are: Introduction; Brief history of development; Some early schemes; Gas turbine developments; Steam generator concepts; The single shaft block; Repowering steam turbines; Combined heat and power; Gas turbines and coal; and What does the future hold?

  9. The use of absorption refrigeration systems in combined cycle power plants; Empleo de sistemas de refrigeracion por absorcion en plantas de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes, H.; Ambriz, J.J.; Vargas, M.; Godinez, M.; Gomez, F.; Valdez, L.; Pantoja, G. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Departamento de Ingenieria de Procesos e Hidraulica, Mexico D. F. (Mexico)

    1995-12-31

    Day after day the electric power generation tends to be done in the most efficient way in order to diminish the generation costs and the rate of environmental pollution per KWh generated. This paper discusses the application of absorption refrigeration systems for the cooling of the air entering the compressor of a gas turbine in a combined cycle, in order to increase the mass air flow and with it the turbine output. The flows with remanent energy content that are not used in a combined cycle can be used for the operation of the absorption refrigeration system. This way, the required thermal energy for the cooling system is free. With this system it is possible to raise the gas turbine generation output from 5% to 25%. [Espanol] La generacion electrica dia con dia pretende realizarse de la manera mas eficiente posible con el objeto de disminuir los costos de generacion y la tasa de contaminacion ambiental por Kwh generado. En el presente trabajo se introduce la aplicacion de sistemas de refrigeracion por absorcion para el enfriamiento del aire de entrada al compresor de la turbina de gas de un ciclo combinado, con el objeto de aumentar el flujo masico del aire y con ello la potencia de salida de la turbina. Las corrientes con contenido remanente de energia termica que no se usan en una planta de ciclo combinado pueden servir para operar el sistema de refrigeracion por absorcion. De esta manera, la energia termica requerida para el sistema de enfriamiento es gratuita. Con este sistema es posible incrementar la potencia de generacion de la turbina de gas de 5 a 25%.

  10. Generalized conventional and intelligent supervisory control system for combined cycle generation power plants; Sistema de control supervisorio generalizado convencional e inteligente para centrales de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Morales, Miguel Angel

    2004-12-15

    The Mexican Electricity Utility (Comision Federal de Electricidad - CFE) growing program in Power Generation for the 2004 - 2008 period is based on Combined Cycle Power Plants (CCPP). In accordance with [CFE, 2000], the expected power generation capacity developed during such period will rise by the amount of 12876 MW, 10655 MW belonging to CCPP (82.75 %). With such important program for the increasing of Power Generation in Mexico, researches have to receive new technologies for CCPP, some of them not completely tested and immature, with the compromise to make then more efficient and reliable. Under such idea and looking to increase the automation level for CCPP with better control algorithms, the Supervisory Generalized Control (SGC) for CCPP was developed in this thesis, based on PID strategies and intelligent (fuzzy) control strategies. With the SGC is possible to get the best performance for the whole CCPP through the automatic starting, synchronizing and loading of the generating units (two gas turbines and one steam turbine) with a minimum participation of operators. To get the increased efficiency, the SGC generates the reference paths for both gas turbines (GT) first, and the steam turbine (ST). The SGC accelerates each unit with a minimum effort and vibrations getting the synchronizing speed in a minimum time and wasted energy. Then the SGC synchronize each unit taking minimum load quickly and loading up to the highest electric power value. All these can be done in an automated operation. The SGC employs two critical-process variable- control strategies, based on blade path temperature average (BPT Average) for Gas Turbines (GT) and the throttle steam pressure for the Steam Turbine (ST). The control algorithms designed take both units, the GT and the ST, picking up load to the highest process value avoiding the alarms activation and shutdown. This is possible only with such an automated control strategy. Test performed showed that with the SGC

  11. Combined cycle power plant technology: efficient generation of electrical power with a variety of fuels. Pt. 2; Die Gas- und Dampfturbinen-(GuD)-Kraftwerks-Technologie: effiziente Stromerzeugung aus unterschiedlichen Energietraegern. T. 2

    Energy Technology Data Exchange (ETDEWEB)

    Gudenau, H.W. [Inst. fuer Eisenhuettenkunde der Rheinisch-Westfaelischen Technischen Hochschule, Aachen (Germany); Dornbusch, H. [Inst. fuer Eisenhuettenkunde der Rheinisch-Westfaelischen Technischen Hochschule, Aachen (Germany); Hahn, W. [Inst. fuer Eisenhuettenkunde der Rheinisch-Westfaelischen Technischen Hochschule, Aachen (Germany); Hoberg, H. [Inst. fuer Eisenhuettenkunde der Rheinisch-Westfaelischen Technischen Hochschule, Aachen (Germany); Mayerhofer, A. [Inst. fuer Eisenhuettenkunde der Rheinisch-Westfaelischen Technischen Hochschule, Aachen (Germany); Meimeth, S. [Inst. fuer Eisenhuettenkunde der Rheinisch-Westfaelischen Technischen Hochschule, Aachen (Germany); Scharpff, T. [Inst. fuer Eisenhuettenkunde der Rheinisch-Westfaelischen Technischen Hochschule, Aachen (Germany)

    1993-05-01

    Part 2 is occupied with the production of burning gases (gasification of solid and liquid fuels) and the use of industrial by-product gases (steel plant gases) in a combined cycle power plant. An allmost complete in-situ desulphurisation of hot gasified coal with small amount of additives was achieved. Over 98% of alkalies could be removed. Trials on dechlorination were made in the High-Temperature-Winkler (HTW)-Reactor. (orig./GL) [Deutsch] Der zweite Teil beschaeftigt sich mit der Ergaenzung von Brenngasen (HTW-Vergasung fester und fluessiger Kohlenstofftraeger), der Verwertung industrieller brennbarer Abgase (Huettengase) und deren Nutzbarmachung fuer den GuD-Prozess. Bei der in situ-Reinigung der Brenngase mittels geringer Additivmengen wurde eine nahezu vollstaendige Entschwefelung erreicht. Alkalien konnten zu ueber 98% entfernt werden. Versuche zur Entchlorung werden an der HTW-Technikumsanlage des IEHK durchgefuehrt. (orig./GL)

  12. Co-generation project for the Combined Cycle Power Plant President Juarez Rosarito and a reverse osmosis desalting plant; Proyecto de cogeneracion para la planta de ciclo combinado Presidente Juarez Rosarito y una planta desaladora de osmosis inversa

    Energy Technology Data Exchange (ETDEWEB)

    Beltran Mora, Hector; Espindola Hernandez, Salvador [Universidad NAcional Autonoma de Mexico (UNAM), Mexico, D.F. (Mexico)

    2006-11-15

    In this work a technical and economical analysis of the installation of a reverse osmosis desalting plant connected to a power station that uses the combined cycle technology under a co-generation scheme is presented: production of electricity and water. The operation program of the desalting power station will be determined by the demand of energy of the combined cycle power station; the proposal is that the desalting plant operates in the hours of low load of the power station and shuts down at the peak hours of electrical energy demand. So that this study is representative, the demand curves of electric energy of the units of combined cycle of Central President Juarez Rosarito of the Comision Federal de Electricidad (CFE) have been taken and updated the data of the reverse osmosis desalting plants that are available at the moment in the market. As basis of the study the level costs will be determined so much as the electrical energy generated by the power station of combined cycle, operating inside and outside of a co-generation scheme and the costs made level for the water produced by the reverse osmosis plant under two assumptions: the first one is buying the electrical energy from CFE and the second one considering that the CFE is the owner of the desalting plant and therefore the cost of electrical energy to desalting the plant is zero. This work shows the economic impacts on the costs of the generation of electrical energy and on those of the desalted water in a co-generation scheme. The results shown in this study can be considered for the future planning in the construction of desalting plants to supply of water in the Northwestern zones of the country where serious problems of water shortage exist. [Spanish] En este trabajo se presenta un analisis tecnico y economico de la instalacion de una planta desaladora de osmosis inversa acoplada a una central de generacion de energia electrica que utiliza la tecnologia de ciclo combinado bajo un esquema de

  13. Investigation of dynamic load changes of a combined cycle power plant with circulating pressurized fluidized bed using a simulation model; Untersuchungen zum dynamischen Lastaenderungsverhalten eines Kombi-Kraftwerks mit zirkulierender Druckwirbelschicht mit Hilfe eines Simulationsmodells

    Energy Technology Data Exchange (ETDEWEB)

    Bockamp, S.; Krumm, W.

    2001-07-01

    Fluidized bed combustion technology offers high efficient power plants with low emissions using coal, biomass or waste as fuel input. Mathematical models support the optimisation and design of power plants. The mathematical fluidized bed system model developed at the Institut fuer Energietechnik, Universitaet Siegen, allows the simulation of steady state or dynamic process operation behaviour. This model is used for detailed examining of the overall combined cycle power plant and the interactions between the single components gas turbine, furnace and water-/steam cycle. The described simulation model presented in this paper is applied for the determination of the transient operation behaviour of a combined cycle power plant based on pressurized circulating fluidized bed combustion. The effects of a step function load change on the temperature profile, the emissions and on process reaction of water/steam cycle and on gas turbine is analysed and discussed in detail at different component outlets. (orig.) [German] Das Kombi-Kraftwerk mit zirkulierender Druckwirbelschichtfeuerung stellt ein effizientes und emissionsarmes Konzept dar. Neben den wirbelschichtinhaerenten Eigenschaften wie geringerer Schadstoffbildung durch niedrige Feuerraumtemperaturen und der integrierten Schadstoffreduktion durch die Zugabe von Zuschlagstoffen verspricht die druckaufgeladenen Variante aufgrund der hohen Querschnittsbelastung eine kompakte Bauart sowie einen fuer die Verstromung von Kohlen hohen Wirkungsgrad. Kohle kann mit diesem Verfahren direkt innerhalb eines Gasturbinenprozesses genutzt werden. Mit Hilfe der mathematischen Modellbildung koennen die dynamischen Auswirkungen auf das Gesamtsystem Kombi-Kraftwerk untersucht werden. (orig.)

  14. INTEGRATED PYROLYSIS COMBINED CYCLE BIOMASS POWER SYSTEM CONCEPT DEFINITION

    Energy Technology Data Exchange (ETDEWEB)

    Eric Sandvig; Gary Walling; Robert C. Brown; Ryan Pletka; Desmond Radlein; Warren Johnson

    2003-03-01

    Advanced power systems based on integrated gasification/combined cycles (IGCC) are often presented as a solution to the present shortcomings of biomass as fuel. Although IGCC has been technically demonstrated at full scale, it has not been adopted for commercial power generation. Part of the reason for this situation is the continuing low price for coal. However, another significant barrier to IGCC is the high level of integration of this technology: the gas output from the gasifier must be perfectly matched to the energy demand of the gas turbine cycle. We are developing an alternative to IGCC for biomass power: the integrated (fast) pyrolysis/ combined cycle (IPCC). In this system solid biomass is converted into liquid rather than gaseous fuel. This liquid fuel, called bio-oil, is a mixture of oxygenated organic compounds and water that serves as fuel for a gas turbine topping cycle. Waste heat from the gas turbine provides thermal energy to the steam turbine bottoming cycle. Advantages of the biomass-fueled IPCC system include: combined cycle efficiency exceeding 37 percent efficiency for a system as small as 7.6 MW{sub e}; absence of high pressure thermal reactors; decoupling of fuel processing and power generation; and opportunities for recovering value-added products from the bio-oil. This report provides a technical overview of the system including pyrolyzer design, fuel clean-up strategies, pyrolysate condenser design, opportunities for recovering pyrolysis byproducts, gas turbine cycle design, and Rankine steam cycle. The report also reviews the potential biomass fuel supply in Iowa, provide and economic analysis, and present a summery of benefits from the proposed system.

  15. Development of Natural Gas Fired Combined Cycle Plant for Tri-Generation of Power, Cooling and Clean Water Using Waste Heat Recovery: Techno-Economic Analysis

    OpenAIRE

    Gowtham Mohan; Sujata Dahal; Uday Kumar; Andrew Martin; Hamid Kayal

    2014-01-01

    Tri-generation is one of the most efficient ways for maximizing the utilization of available energy. Utilization of waste heat (flue gases) liberated by the Al-Hamra gas turbine power plant is analyzed in this research work for simultaneous production of: (a) electricity by combining steam rankine cycle using heat recovery steam generator (HRSG); (b) clean water by air gap membrane distillation (AGMD) plant; and (c) cooling by single stage vapor absorption chiller (VAC). The flue gases liber...

  16. Generating power at high efficiency combined cycle technology for sustainable energy production

    CERN Document Server

    Jeffs, E

    2008-01-01

    Combined cycle technology is used to generate power at one of the highest levels of efficiency of conventional power plants. It does this through primary generation from a gas turbine coupled with secondary generation from a steam turbine powered by primary exhaust heat. Generating power at high efficiency thoroughly charts the development and implementation of this technology in power plants and looks to the future of the technology, noting the advantages of the most important technical features - including gas turbines, steam generator, combined heat and power and integrated gasification com

  17. Discussion on Flue Gas Waste Heat Utilization technology of Heavy(F Class)Gas-steam Combined Cycle Power Plant%大型F级燃气蒸汽联合循环烟气余热利用探讨

    Institute of Scientific and Technical Information of China (English)

    章正传; 殷俊; 李懿靓

    2014-01-01

    本文探讨了大型F级联合循环机组利用烟气余热进行凝结水/给水加热、燃料气加热,进气冷却,以及利用烟气余热制冷和采暖方面的应用,分析表明,大型联合循环电厂烟气余热利用潜力较大,充分利用烟气余热,具有一定的节能意义。%This paper discusses flue gas waste heat utilization of Heavy(F Class)Gas- steam Combined Cycle Power Plant ,which used in condensed water /feed water heating, fuel gas heating, air cooling, and refrigeration and heating. Analysis shows that, the large combined cycle power plant flue gas waste heat utilization potential, make full use of the waste heat of the flue gas, has certain significance of energy saving.

  18. Basic survey project for joint implementation in fiscal 1998. Study of BFG mono-firing gas turbine combined cycle power plant application for the steel mill of China; 1998 nendo kyodo jisshi nado suishin kiso chosa. Chugoku seitetsu kaishamuke koro gas sensho combined cycle hatsuden setsubi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Discussions were given on application to the steel mills in China of a 1100-degree C class high-efficiency combined cycle power plant (CCPP) exclusively firing blast furnace gas developed jointly by Kawasaki Heavy Industries Ltd. of Japan and ABB Corporation of Switzerland. The CCPP can utilize the energy possessed by a fuel without waste from high temperature zones to low temperature zones, being capable of attaining high efficiency that cannot be achieved with the single cycle. The CCPP has the efficiency exceeding that of the BTGP by about 10% or more in absolute value. The investigations and discussions were given on Shougang General Corporation, Anshan Steel Corporation and Wuhan Steel Corporation. As a result, in the plan for the power plant of Shougang General Corporation on which both parties have agreed, the project implementation can be expected to result in electric power generation of 110 MW in annual average, factory air supply of about 100 tons per hour in annual average, and annual reduction of carbon dioxide of 841 kilo tons. Wuhan Steel and Anshan Steel will require implementation of further detailed investigation, but the possibility of realization is considered high (NEDO)

  19. PNEM cuts NO[sub x] with GT10 combined cycle cogen plants

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1994-03-01

    A combined cycle cogeneration plant commissioned by the Dutch utility NV Provincale Noordbrabantse Energie Maatschappij (PNEM) in s'Hertogenbosch in the Netherlands is now in commercial operation. The site is adjacent to the famous Heineken brewery. The ABB GT10 gas turbine to be used with the boiler supplied by Schelde Breda Boilers, will be the first gas turbine in The Netherlands in this power range (24 MW) with combustion chambers of the dry low NO[sub x] type. (author)

  20. Technological tendencies for the development and implementation of fault tolerant active controls in combined cycle power plants; Tendencias tecnologicas para el desarrollo e implantacion de controles activos tolerantes a fallas en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez P, Marino; Verde R, Cristina [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2006-07-01

    This document proposes a methodology that reunites support tools for the operator of a Combined Cycle Generating Power Station allowing him to identify and to classify gas turbine faults, it also reunites some tools for the generation of action advices in the decision making on the operation maneuvers necessary to counteract the effects caused by faults. We are talking about a system implemented in a power station with the reconfiguration of processes and fault arrangement capacities. For this purpose, the line of exhibition delimits first the existing knowledge on automatic control and operations supervision systems in a CCPP and immediately emphasizes the cracks of the system to let pass to the fault tolerant active control system that will detect faults of the gas and steam turbo-generators of a Combined Cycle Generating Power Plant. [Spanish] El presente documento propone una metodologia que reuna herramientas de ayuda al operador de una Central Generadora de Electricidad de Ciclo Combinado para permitirle la identificacion y clasificacion de fallas en las turbinas de gas, asi como herramientas para la generacion de consejos de accion en la toma de decisiones sobre las maniobras de operacion necesarias para contrarrestar los efectos provocados por fallas. Se trata principalmente de un sistema implantado en una central con las capacidades de re-configuracion de procesos y acomodo de fallas. Para esto, la linea de exposicion delimita primero el conocimiento existente sobre sistemas automaticos de control y supervision de operacion en una CGCC y resalta enseguida las grietas del sistema para darle paso al sistema de control activo tolerante a fallas que detectara fallas de los turbogeneradores de gas y vapor de una Central Generadora de Electricidad de Ciclo Combinado.

  1. TECHNOECONOMIC APPRAISAL OF INTEGRATED GASIFICATION COMBINED-CYCLE POWER GENERATION

    Science.gov (United States)

    The report is a technoeconomic appraisal of the integrated (coal) gasification combined-cycle (IGCC) system. lthough not yet a proven commercial technology, IGCC is a future competitive technology to current pulverized-coal boilers equipped with SO2 and NOx controls, because of i...

  2. TECHNOECONOMIC APPRAISAL OF INTEGRATED GASIFICATION COMBINED-CYCLE POWER GENERATION

    Science.gov (United States)

    The report is a technoeconomic appraisal of the integrated (coal) gasification combined-cycle (IGCC) system. lthough not yet a proven commercial technology, IGCC is a future competitive technology to current pulverized-coal boilers equipped with SO2 and NOx controls, because of i...

  3. Smart Operation of Gas Turbine Combined Cycle Plants: Prediction and Improvement of Thermal Efficiency at Part Load

    NARCIS (Netherlands)

    Boksteen, S.Z.

    2014-01-01

    This thesis investigates various operational aspects of Gas Turbine Combined Cycle Power Plants (GTCC). GTCC power plants are expected to play an increasingly important role in the balancing of supply and demand in the electricity grid. Although originally meant for predominantly base load operatio

  4. Smart Operation of Gas Turbine Combined Cycle Plants: Prediction and Improvement of Thermal Efficiency at Part Load

    NARCIS (Netherlands)

    Boksteen, S.Z.

    2014-01-01

    This thesis investigates various operational aspects of Gas Turbine Combined Cycle Power Plants (GTCC). GTCC power plants are expected to play an increasingly important role in the balancing of supply and demand in the electricity grid. Although originally meant for predominantly base load

  5. Smart Operation of Gas Turbine Combined Cycle Plants: Prediction and Improvement of Thermal Efficiency at Part Load

    NARCIS (Netherlands)

    Boksteen, S.Z.

    2014-01-01

    This thesis investigates various operational aspects of Gas Turbine Combined Cycle Power Plants (GTCC). GTCC power plants are expected to play an increasingly important role in the balancing of supply and demand in the electricity grid. Although originally meant for predominantly base load operatio

  6. Gasification/combined-cycle power generation: environmental assessment of alternative systems

    Energy Technology Data Exchange (ETDEWEB)

    1978-11-01

    This report provides a basis for the comparative assessment of the potential performance capability, technological development, and economic and environmental impact associated with the operation of integrated low-Btu coal-gasification/combined-cycle power systems. Characterization of the integrated power system in terms of fuel processing, power production, and auxiliary systems is followed up with comparisons of alternative integrated-plant-design/fuel combinations with reference to the conventional coal-fired power plant, taking into account both economic and environmental factors. The report includes an assessment of the effects of recent regulatory changes on the prospects for integrated power systems and establishes a timetable for the probable commercial development of such systems by the utilities.

  7. Ciclo combinado Diesel-Vapor como repotenciación de una central termoeléctrica: caso de estudio; Combined Cycle Diesel-Steam as Power Plant Repowering: study case

    Directory of Open Access Journals (Sweden)

    Alberto Eduardo Calvo González

    2014-06-01

    Full Text Available La necesidad imperiosa de cubrir el déficit de generación eléctrica ampliando el potencial de generación con motores diesel a fuel oíl, cuya instalación requiere de muy poco tiempo, es una solución adecuada. La idea de aprovechar los nodos del sistema electro energético, como son las subestaciones y las centrales eléctricas, para instalar los grupos electrógenos es una solución apropiada. Pero en el caso de una central termoeléctrica, al montar estas instalaciones de forma independiente, no se aprovechan las posibilidades que la combinación de procesos ofrece como la disminución del consumo de combustible, y de la contaminación ambiental por unidad de energía producida. El presente trabajo explora la posibilidad de instalar plantas eléctricas diesel a fuel oil como ciclo combinado diesel-vapor. Se demuestra la conveniencia de instalar plantas eléctricas diesel a fuel oil como ciclo combinado diesel-vapor, aprovechando la sinergia que se logra por la combinación de los procesos térmicos. The pressing need of covering generation deficit to satisfy the demand in the shorter possible time, by enlarging the generation potential with fuel oil fueled diesel motors, it’s an appropriate solution. The idea of taking advantage of electric grid existent nodes facilities to place the generating electricity diesel motors is a non-unwise solution. But in the case of the node of steam power station place these motors in an independent way, don't take advantage of the possibilities that the processes combination offers, as the combined cycle diesel vapor for example. The work presented herein explored and showed the possibility of installing the electric diesel plants as a repowering the existing steam power plant by combined cycle diesel-steam taking advantage of the synergy achieved by thermal processes combination.

  8. Combined cycle solar central receiver hybrid power system study. Final technical report. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-11-01

    This study develops the conceptual design for a commercial-scale (nominal 100 MWe) central receiver solar/fossil fuel hybrid power system with combined cycle energy conversion. A near-term, metallic heat pipe receiver and an advanced ceramic tube receiver hybrid system are defined through parametric and market potential analyses. Comparative evaluations of the cost of power generation, the fuel displacement potential, and the technological readiness of these two systems indicate that the near-term hybrid system has better potential for commercialization by 1990. Based on the assessment of the conceptual design, major cost and performance improvements are projected for the near-term system. Constraints preventing wide-spread use were not identified. Energy storage is not required for this system and analyses show no economic advantages with energy storage provisions. It is concluded that the solar hybrid system is a cost effective alternative to conventional gas turbines and combined cycle generating plants, and has potential for intermediate-load market penetration at 15% annual fuel escalation rate. Due to their flexibility, simple solar/nonsolar interfacing, and short startup cycles, these hybrid plants have significant operating advantages. Utility company comments suggest that hybrid power systems will precede stand-alone solar plants.

  9. 联合循环电厂大型隔声屏障的优化与效果%Optimization and Effect of Large Sound Barrier in Combined Cycle Power Plant

    Institute of Scientific and Technical Information of China (English)

    何语平

    2001-01-01

    镇海300MW燃气-蒸汽联合循环发电工程采用计算机技术对噪声传播进行模拟和预测,优化了隔声屏障的设计。经工程竣工验收,取得了满意的隔声效果。%Computer technology was used to simulate and forecast the noisespread in Zhenhai 300MW gas-steam combined cycle power generation project. The design of sound barrier was optimized. Satisfactory effect has been achieved on noise control though acceptance checks of the project completion.

  10. Life cycle assessment of a biomass gasification combined-cycle power system

    Energy Technology Data Exchange (ETDEWEB)

    Mann, M.K.; Spath, P.L.

    1997-12-01

    The potential environmental benefits from biomass power are numerous. However, biomass power may also have some negative effects on the environment. Although the environmental benefits and drawbacks of biomass power have been debated for some time, the total significance has not been assessed. This study serves to answer some of the questions most often raised in regard to biomass power: What are the net CO{sub 2} emissions? What is the energy balance of the integrated system? Which substances are emitted at the highest rates? What parts of the system are responsible for these emissions? To provide answers to these questions, a life cycle assessment (LCA) of a hypothetical biomass power plant located in the Midwest United States was performed. LCA is an analytical tool for quantifying the emissions, resource consumption, and energy use, collectively known as environmental stressors, that are associated with converting a raw material to a final product. Performed in conjunction with a technoeconomic feasibility study, the total economic and environmental benefits and drawbacks of a process can be quantified. This study complements a technoeconomic analysis of the same process, reported in Craig and Mann (1996) and updated here. The process studied is based on the concept of power Generation in a biomass integrated gasification combined cycle (BIGCC) plant. Broadly speaking, the overall system consists of biomass production, its transportation to the power plant, electricity generation, and any upstream processes required for system operation. The biomass is assumed to be supplied to the plant as wood chips from a biomass plantation, which would produce energy crops in a manner similar to the way food and fiber crops are produced today. Transportation of the biomass and other materials is by both rail and truck. The IGCC plant is sized at 113 MW, and integrates an indirectly-heated gasifier with an industrial gas turbine and steam cycle. 63 refs., 34 figs., 32 tabs.

  11. Viability analysis of energy generation from a thermoelectric power plant in the city of Rio de Janeiro, Brazil, using combined cycle; Analise da viabilidade de geracao de energia de uma central termeletrica na cidade do Rio de Janeiro operando em ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Thiago Garritano Monteiro; Almeida, Silvio Carlos Anibal de [Universidade Federal do Rio de Janeiro (DEM/UFRJ), RJ (Brazil). Dept. de Engenharia Mecanica], Emails: tgguima@hotmail.com, silvioa@gmail.com

    2010-07-01

    This paper presents a modeling on the economic and energetic viability of a electric power system generation in a thermoelectric plant placed at Rio de Janeiro state, Brazil, using a combined cycle and cogeneration using the software Thermoflow 17.0.0 (academic version). This paper intends to know which is the better alternative of configuration of thermal electric plant among the various possible scenarios and also evaluate the time of return invested capital.

  12. Gas fired combined cycle plant in Singapore: energy use, GWP and cost-a life cycle approach

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, R. [School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)]. E-mail: kannan@pmail.ntu.edu.sg; Leong, K.C. [School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)]. E-mail: mkcleong@ntu.edu.sg; Osman, Ramli [School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Ho, H.K. [School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Tso, C.P. [Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450 Melaka (Malaysia)

    2005-08-15

    A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle power plant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle power plant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established.

  13. COMBINED CYCLE GAS TURBINE FOR THERMAL POWER STATIONS: EXPERIENCE IN DESIGNING AND OPERATION, PROSPECTS IN APPLICATION

    Directory of Open Access Journals (Sweden)

    N. V. Karnitsky

    2014-01-01

    Full Text Available The paper has reviewed main world tendencies in power consumption and power system structure. Main schemes of combined cycle gas turbines have been considered in the paper. The paper contains an operational analysis of CCGT blocks that are operating within the Belarusian energy system. The analysis results have been given in tables showing main operational indices of power blocks

  14. Development of a plant-wide dynamic model of an integrated gasification combined cycle (IGCC) plant

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, D.; Turton, R.; Zitney, S.

    2009-01-01

    In this presentation, development of a plant-wide dynamic model of an advanced Integrated Gasification Combined Cycle (IGCC) plant with CO2 capture will be discussed. The IGCC reference plant generates 640 MWe of net power using Illinois No.6 coal as the feed. The plant includes an entrained, downflow, General Electric Energy (GEE) gasifier with a radiant syngas cooler (RSC), a two-stage water gas shift (WGS) conversion process, and two advanced 'F' class combustion turbines partially integrated with an elevated-pressure air separation unit (ASU). A subcritical steam cycle is considered for heat recovery steam generation. Syngas is selectively cleaned by a SELEXOL acid gas removal (AGR) process. Sulfur is recovered using a two-train Claus unit with tail gas recycle to the AGR. A multistage intercooled compressor is used for compressing CO2 to the pressure required for sequestration. Using Illinois No.6 coal, the reference plant generates 640 MWe of net power. The plant-wide steady-state and dynamic IGCC simulations have been generated using the Aspen Plus{reg_sign} and Aspen Plus Dynamics{reg_sign} process simulators, respectively. The model is generated based on the Case 2 IGCC configuration detailed in the study available in the NETL website1. The GEE gasifier is represented with a restricted equilibrium reactor model where the temperature approach to equilibrium for individual reactions can be modified based on the experimental data. In this radiant-only configuration, the syngas from the Radiant Syngas Cooler (RSC) is quenched in a scrubber. The blackwater from the scrubber bottom is further cleaned in the blackwater treatment plant. The cleaned water is returned back to the scrubber and also used for slurry preparation. The acid gas from the sour water stripper (SWS) is sent to the Claus plant. The syngas from the scrubber passes through a sour shift process. The WGS reactors are modeled as adiabatic plug flow reactors with rigorous kinetics based on

  15. Tampa Electric Company`s Polk Power Station Integrated Gasification Combined Cycle Project

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S.D.; Shafer, J.R.

    1994-12-31

    Tampa Electric Company (TEC) is in the construction phase for the new Polk Power Station, Unit {number_sign}1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) technology for power generation. The unit will utilize oxygen-blown entrained-flow coal gasification, along with combined cycle technology, to provide nominal net 26OMW of generation. As part of the environmental features of this process, the sulfur species in the coal will be recovered as a commercial grade sulfuric acid by-product. The sulfur will be removed from the synthesis gas utilizing a cold gas clean-up system (CGCU).

  16. Thermoeconomic analysis of Biomass Integrated Gasification Gas Turbine Combined Cycle (BIG GT CC) cogeneration plant

    Energy Technology Data Exchange (ETDEWEB)

    Arrieta, Felipe Raul Ponce; Lora, Electo Silva [Escola Federal de Engenharia de Itajuba, MG (Brazil). Nucleo de Estudos de Sistemas Termicos]. E-mails: aponce@iem.efei.br; electo@iem.efei.br; Perez, Silvia Azucena Nebra de [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Energia]. E-mail: sanebra@fem. unicamp.br

    2000-07-01

    Using thermoeconomics as a tool to identify the location and magnitude of the real thermodynamic losses (energy waste, or exergy destruction and exergy losses) it is possible to assess the production costs of each product (electric power and heat) and the exergetic and exergoeconomic cost of each flow in a cogeneration plant to assist in decision-marketing procedures concerning to plant design, investment, operation and allocations of research funds. Thermo economic analysis of Biomass Integrated Gasification Gas Turbine Combined Cycle (BIG GT CC) cogeneration plant for its applications in sugar cane mills brings the following results: the global exergetic efficiency is low; the highest irreversibilities occur in the following equipment, by order: scrubber (38%), gas turbine (16%), dryer (12%), gasifier and HRSG (6%); due to the adopted cost distribution methodology, the unit exergetic cost of the heat (4,11) is lower than electricity (4,71); the lower market price of biomass is one of the most sensible parameter in the possible implementation of BIG-GT technology in sugar cane industry; the production costs are 31 US$/MWh and 32 US$/MWh for electricity and heat, respectively. The electricity cost is, after all, competitive with the actual market price. The electricity and heat costs are lower or almost equal than other values reported for actual Rankine cycle cogeneration plants. (author)

  17. Design for the 145MW blast furnance gas firing gas turbine combined cycle plant

    Energy Technology Data Exchange (ETDEWEB)

    Takano, H. (Kawasaki Steel Corp., Chiba (Japan). Technical Research Lab.); Kitauchi, Y.; Hiura, H. (Mitsubishi Heavy Industries Ltd., Takasago, Hyogo (Japan). Takasago Works)

    1988-01-01

    A 145 MW blast furnance gas firing gas turbine combined cycle plant was designed and installed in a steel works of Japan as a repowering unit. A 124 MW large scale gas turbine with turbine inlet temperature 1150{sup {degrees}}C (1423 K) was adopted as a core engine for the combined cycle plant. The fuel of this gas turbine is blast furnace gas mixed with coke oven gas which are byproducts in steel works, and the calorific value of the mixed gas to be controlled is about 1000 kcal/Nm{sup 3} (4187 kJ/Nm{sup 3}). A specially designed multi-cannular type combustor was developed to burn such a low BTV fuel. The gas turbine, generator, steam turbine and fuel gas compressor are connected to make a single shaft configuration. As a result of this introducing the gas turbine combined cycle plant, the plant thermal efficiency was achieved above 45% (at NET) and the total electricity generation in the works is increased from 243 MW to 317 MW. This paper describes the design features of this combined cycle plant.

  18. Integrated coal gasification combined cycle

    Science.gov (United States)

    Richards, P. C.; Wijffels, J.-B.; Zuideveld, P. L.

    Features of the integrated coal gasification combined cycle power plants are described against the backdrop of the development and first commercial application of the shell coal gasification process. Focus is on the efficiency and excellent environmental performance of the integrated coal gasification combined power plants. Current IGCC projects are given together with an outline of some of the options for integrating coal gasification with combined cycles and also other applications of synthesis gas.

  19. Possibilities for the further development of combined cycle power station technology. Moeglichkeiten zur Weiterentwicklung der Kombi-Kraftwerkstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Adlhoch, W. (Rheinbraun AG, Koeln (Germany)); Bolt, N. (KEMA, Arnheim (Netherlands))

    1994-07-01

    Power plant technology has to make a contribution towards the reduction of the global damage of the climate due to the greenhouse effect. Ways of reducing CO[sub 2] emissions are found in the first place in better utilization of the primary energy used. Possibilities for further development of combined cycle power plant technology are described with the aid of selected examples. In addition to theoretical considerations, the paper also describes current development projects, which demonstrate the potential of process engineering and component development. (orig.)

  20. Intelligent control system for the temperature regulation in a gas turbine of a combined cycle fossil fuel power plant; Sistema de control inteligente para regular la temperatura en la turbina de gas de una central termoelectrica de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Espindola Vasquez, Agustin

    2004-11-15

    In the Turbogas Units (UTG short for Spanish acronym) of a Thermoelectric Power station of Combined Cycle (CTCC short for Spanish acronym), from an operative, as well as a safety standpoint the turbine blade temperature is a critical variable. The best performance of a turbogas unit based in the electrical generation is obtained when the greatest thermal efficiency is reached. From the point of view of safety, it is desirable to keep the blades temperature at the limit established by the manufacturer, guaranteeing with this, the integrity of the UTG internal parts; avoiding that great thermal efforts decrease their useful life. In order to keep the blades temperature at the established limit, the UTG control system have a supervision system of blades temperature, that system modifies the controllers reference of the speed or power PI's which regulate the fuel valve of the UTG combustion chamber. This supervision system is based on logic conditions to generate its exit signal. In the process plants whose operation is complex and its dynamic behavior is nonlinear, the strategies of control of single loop do not provide the wished performance when they are applied in control loops to regulate critical variables; thing doing necessary the design of structures with two hierarchical levels; one with direct control and the other with supervisory control. The fuzzy logic has found a wide acceptance [Chiu, 1998] when is used to handle control functions of high level which are outside of the dominion of the conventional control methods. One of these cases is the application of the fuzzy logic to the supervisory control. In this thesis document is presented the accomplishment of a temperature fuzzy supervision system in a turbogas unit, whose purpose is to keep the turbine blades temperature within the established limits, conserving a satisfactory performance from an operative, as well as a safety standpoint. The temperature supervisor was designed with base on fuzzy

  1. Fault diagnosis in the steam turbo-generator of a Combined Cycle Power Plant; Diagnostico de fallas en el turbogenerador a vapor de una central de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Flores Abad, Angel

    2006-12-15

    Due to the physical nature of its components, technological processes are vulnerable to faults. These faults affect the accurate behavior of the system, causing a performance reduction, even great economical losses and in the worst case environmental and human disasters. The opportune detection of the presence of faults helps to take corrective actions and as a consequence to reduce the potential damage that faults cause. To achieve the fault detection task, technological processes have supervisory systems to monitor the process variables and provide an alarm when a variable reached a given threshold. This method has the drawback that a single fault could cause many system alarms, which difficult the fault isolation. In addition it is based on hardware redundancy; it means the use of repeated devices to do the same work. Combined cycle power plants (CCPP) are large scale systems with a high degree of fault susceptibility. Due to strict conditions in which they operate and the great number of elements they contain, including sensors and actuators. Nowadays this kind of power plants tends to dominate the electric generation market by means of fossil fuels, because they are the most efficient, profitable, with flexible operation and with less environmental impact. In the CCPP, the steam turbine (ST) is a fundamental component, since it represents the process gain, in the way that it allows the generation of additional electric energy by taking advantage of the exhaust gases of the gas turbines. In case of the ST fails, the global efficiency of the process is reduced even in a 40%. In this work a model based fault diagnosis system was developed, according to the FDI (Fault Detection and Isolation) methodology of the control theory, with the capability of detecting and isolating faults in the sensors and actuators of the ST of a CCPP. The developed system is based on the analytical redundancy which allows optimizing the hardware redundancy and getting a reduction of the

  2. Recovery Act: Johnston Rhode Island Combined Cycle Electric Generating Plant Fueled by Waste Landfill Gas

    Energy Technology Data Exchange (ETDEWEB)

    Galowitz, Stephen

    2013-06-30

    The primary objective of the Project was to maximize the productive use of the substantial quantities of waste landfill gas generated and collected at the Central Landfill in Johnston, Rhode Island. An extensive analysis was conducted and it was determined that utilization of the waste gas for power generation in a combustion turbine combined cycle facility was the highest and best use. The resulting project reflected a cost effective balance of the following specific sub-objectives. 1) Meet environmental and regulatory requirements, particularly the compliance obligations imposed on the landfill to collect, process and destroy landfill gas. 2) Utilize proven and reliable technology and equipment. 3) Maximize electrical efficiency. 4) Maximize electric generating capacity, consistent with the anticipated quantities of landfill gas generated and collected at the Central Landfill. 5) Maximize equipment uptime. 6) Minimize water consumption. 7) Minimize post-combustion emissions. To achieve the Project Objective the project consisted of several components. 1) The landfill gas collection system was modified and upgraded. 2) A State-of-the Art gas clean up and compression facility was constructed. 3) A high pressure pipeline was constructed to convey cleaned landfill gas from the clean-up and compression facility to the power plant. 4) A combined cycle electric generating facility was constructed consisting of combustion turbine generator sets, heat recovery steam generators and a steam turbine. 5) The voltage of the electricity produced was increased at a newly constructed transformer/substation and the electricity was delivered to the local transmission system. The Project produced a myriad of beneficial impacts. 1) The Project created 453 FTE construction and manufacturing jobs and 25 FTE permanent jobs associated with the operation and maintenance of the plant and equipment. 2) By combining state-of-the-art gas clean up systems with post combustion emissions control

  3. HTR-Based Power Plants’ Performance Analysis Applied on Conventional Combined Cycles

    Directory of Open Access Journals (Sweden)

    José Carbia Carril

    2015-01-01

    Full Text Available In high temperature reactors including gas cooled fast reactors and gas turbine modular helium reactors (GT-MHR specifically designed to operate as power plant heat sources, efficiency enhancement at effective cost under safe conditions can be achieved. Mentioned improvements concern the implementation of two cycle structures: (a, a stand alone Brayton operating with helium and a stand alone Rankine cycle (RC with regeneration, operating with carbon dioxide at ultrasupercritical pressure as working fluid (WF, where condensation is carried out at quasicritical conditions, and (b, a combined cycle (CC, in which the topping closed Brayton cycle (CBC operates with helium as WF, while the bottoming RC is operated with one of the following WFs: carbon dioxide, xenon, ethane, ammonia, or water. In both cases, an intermediate heat exchanger (IHE is proposed to provide thermal energy to the closed Brayton or to the Rankine cycles. The results of the case study show that the thermal efficiency, through the use of a CC, is slightly improved (from 45.79% for BC and from 50.17% for RC to 53.63 for the proposed CC with He-H2O operating under safety standards.

  4. Transient studies of an Integrated Gasification Combined Cycle (IGCC) plant with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, D.; Turton, R.; Zitney, S.

    2010-01-01

    Next-generation coal-fired power plants need to consider the option for CO2 capture as stringent governmental mandates are expected to be issued in near future. Integrated gasification combined cycle (IGCC) plants are more efficient than the conventional coal combustion processes when the option for CO2 capture is considered. However, no IGCC plant with CO2 capture currently exists in the world. Therefore, it is important to consider the operability and controllability issues of such a plant before it is commercially built. To facilitate this objective, a detailed plant-wide dynamic simulation of an IGCC plant with 90% CO2 capture has been developed in Aspen Plus Dynamics{reg_sign}. The plant considers a General Electric Energy (GEE)-type downflow radiant-only gasifier followed by a quench section. A two-stage water gas shift (WGS) reaction is considered for conversion of CO to CO2. A two-stage acid gas removal (AGR) process based on a physical solvent is simulated for selective capture of H2S and CO2. Compression of the captured CO2 for sequestration, an oxy-Claus process for removal of H2S and NH3, black water treatment, and the sour water treatment are also modeled. The tail gas from the Claus unit is recycled to the SELEXOL unit. The clean syngas from the AGR process is sent to a gas turbine followed by a heat recovery steam generator. This turbine is modeled as per published data in the literature. Diluent N2 is used from the elevated-pressure ASU for reducing the NOx formation. The heat recovery steam generator (HRSG) is modeled by considering generation of high-pressure, intermediate-pressure, and low-pressure steam. All of the vessels, reactors, heat exchangers, and the columns have been sized. The basic IGCC process control structure has been synthesized by standard guidelines and existing practices. The steady state results are validated with data from a commercial gasifier. In the future grid-connected system, the plant should satisfy the environmental

  5. Model predictive control system and method for integrated gasification combined cycle power generation

    Science.gov (United States)

    Kumar, Aditya; Shi, Ruijie; Kumar, Rajeeva; Dokucu, Mustafa

    2013-04-09

    Control system and method for controlling an integrated gasification combined cycle (IGCC) plant are provided. The system may include a controller coupled to a dynamic model of the plant to process a prediction of plant performance and determine a control strategy for the IGCC plant over a time horizon subject to plant constraints. The control strategy may include control functionality to meet a tracking objective and control functionality to meet an optimization objective. The control strategy may be configured to prioritize the tracking objective over the optimization objective based on a coordinate transformation, such as an orthogonal or quasi-orthogonal projection. A plurality of plant control knobs may be set in accordance with the control strategy to generate a sequence of coordinated multivariable control inputs to meet the tracking objective and the optimization objective subject to the prioritization resulting from the coordinate transformation.

  6. Method and system to estimate variables in an integrated gasification combined cycle (IGCC) plant

    Science.gov (United States)

    Kumar, Aditya; Shi, Ruijie; Dokucu, Mustafa

    2013-09-17

    System and method to estimate variables in an integrated gasification combined cycle (IGCC) plant are provided. The system includes a sensor suite to measure respective plant input and output variables. An extended Kalman filter (EKF) receives sensed plant input variables and includes a dynamic model to generate a plurality of plant state estimates and a covariance matrix for the state estimates. A preemptive-constraining processor is configured to preemptively constrain the state estimates and covariance matrix to be free of constraint violations. A measurement-correction processor may be configured to correct constrained state estimates and a constrained covariance matrix based on processing of sensed plant output variables. The measurement-correction processor is coupled to update the dynamic model with corrected state estimates and a corrected covariance matrix. The updated dynamic model may be configured to estimate values for at least one plant variable not originally sensed by the sensor suite.

  7. Analysis of R&D Strategy for Advanced Combined Cycle Power Systems

    Science.gov (United States)

    Akimoto, Keigo; Hayashi, Ayami; Kosugi, Takanobu; Tomoda, Toshimasa

    This article analyzes and evaluates the R&D strategy for advanced power generation technologies, such as natural gas combined cycles, IGCCs (Integrated coal Gasification Combined Cycles), and large-scale fuel cell power generation systems with a mixed-integer programming model. The R&D processes are explicitly formulated in the model through GERT (Graphical Evaluation and Review Technique), and the data on each required time of R&D was collected through questionnaire surveys among the experts. The obtained cost-effective strategy incorporates the optimum investment allocation among the developments of various elemental technologies, and at the same time, it incorporates the least-cost expansion planning of power systems in Japan including other power generation technologies such as conventional coal, oil, and gas fired, and hydro and wind power. The simulation results show the selection of the cost-effective technology developments and the importance of the concentrated investments in them. For example, IGCC, which has a relatively high thermal efficiency, and LNG-CCs of the assumed two efficiencies are the cost-effective investment targets in the no-CO2-regulation case.

  8. Recovery Act: Brea California Combined Cycle Electric Generating Plant Fueled by Waste Landfill Gas

    Energy Technology Data Exchange (ETDEWEB)

    Galowitz, Stephen

    2012-12-31

    The primary objective of the Project was to maximize the productive use of the substantial quantities of waste landfill gas generated and collected at the Olinda Landfill near Brea, California. An extensive analysis was conducted and it was determined that utilization of the waste gas for power generation in a combustion turbine combined cycle facility was the highest and best use. The resulting Project reflected a cost effective balance of the following specific sub-objectives: • Meeting the environmental and regulatory requirements, particularly the compliance obligations imposed on the landfill to collect, process and destroy landfill gas • Utilizing proven and reliable technology and equipment • Maximizing electrical efficiency • Maximizing electric generating capacity, consistent with the anticipated quantities of landfill gas generated and collected at the Olinda Landfill • Maximizing equipment uptime • Minimizing water consumption • Minimizing post-combustion emissions • The Project produced and will produce a myriad of beneficial impacts. o The Project created 360 FTE construction and manufacturing jobs and 15 FTE permanent jobs associated with the operation and maintenance of the plant and equipment. o By combining state-of-the-art gas clean up systems with post combustion emissions control systems, the Project established new national standards for best available control technology (BACT). o The Project will annually produce 280,320 MWh’s of clean energy o By destroying the methane in the landfill gas, the Project will generate CO2 equivalent reductions of 164,938 tons annually. The completed facility produces 27.4 MWnet and operates 24 hours a day, seven days a week.

  9. Combined cycles with gas turbine engines

    Energy Technology Data Exchange (ETDEWEB)

    Najjar, Y.S.H.; Akyurt, M. (King Abdulaziz Univ., Jeddah (Saudi Arabia). Mechanical Engineering Dept.)

    1994-03-01

    Simple cycle gas turbine engines suffer from limited efficiencies and consequential dominance of fuel prices on generation costs. Combined cycles, however. exploit the waste heat from exhaust gases to boost power output, resulting in overall efficiencies around 50%, which are significantly above those of steam power plants. This paper reviews various types of combined cycles, including repowering, integrated gasification and other advanced systems. (author)

  10. Thermodynamic System Studies for a Natural Gas Combined Cycle (NGCC) Plant with CO2 Capture and Hydrogen Storage with Metal Hydrides

    NARCIS (Netherlands)

    Thallam Thattai, A.; Wittebrood, B.J.; Woudstra, T.; Geerlings, J.J.C.; Aravind, P.V.

    2014-01-01

    Flexibility in natural gas combined cycle power plants (NGCC) with pre-combustion CO2 capture could be introduced with co-production of hydrogen and subsequent hydrogen storage with metal hydrides (MH). The current work presents a thermodynamic analysis and comparison between steady state ASPEN Plus

  11. Thermodynamic System Studies for a Natural Gas Combined Cycle (NGCC) Plant with CO2 Capture and Hydrogen Storage with Metal Hydrides

    NARCIS (Netherlands)

    Thallam Thattai, A.; Wittebrood, B.J.; Woudstra, T.; Geerlings, J.J.C.; Aravind, P.V.

    2014-01-01

    Flexibility in natural gas combined cycle power plants (NGCC) with pre-combustion CO2 capture could be introduced with co-production of hydrogen and subsequent hydrogen storage with metal hydrides (MH). The current work presents a thermodynamic analysis and comparison between steady state ASPEN Plus

  12. Prospective gas turbine and combined-cycle units for power engineering (a Review)

    Science.gov (United States)

    Ol'khovskii, G. G.

    2013-02-01

    The modern state of technology for making gas turbines around the world and heat-recovery combined-cycle units constructed on their basis are considered. The progress achieved in this field by Siemens, Mitsubishi, General Electric, and Alstom is analyzed, and the objectives these companies set forth for themselves for the near and more distant future are discussed. The 375-MW gas turbine unit with an efficiency of 40% produced by Siemens, which is presently the largest one, is subjected to a detailed analysis. The main specific features of this turbine are that the gas turbine unit's hot-path components have purely air cooling, due to which the installation has enhanced maneuverability. The single-shaft combined-cycle plant constructed on the basis of this turbine has a capacity of 570 MW and efficiency higher than 60%. Programs adopted by different companies for development of new-generation gas turbine units firing synthesis gas and fitted with low-emission combustion chambers and new cooling systems are considered. Concepts of rotor blades for new gas turbine units with improved thermal barrier coatings and composite blades different parts of which are made of materials selected in accordance with the conditions of their operation are discussed.

  13. Coal waste slurries as a fuel for integrated gasification combined cycle plants

    Directory of Open Access Journals (Sweden)

    Lutynski Marcin A.

    2016-01-01

    Full Text Available The article summarizes recent development in integrated gasification combined cycle technology and lists existing and planned IGCC plants. A brief outlook on the IGCC gasification technology is given with focus on entrained-flow gasifiers where the low-quality coal waste slurry fuel can be used. Desired properties of coal and ash for entrained-flow gasifiers are listed. The coal waste slurries, which were deposited at impoundments in Upper Silesian Coal Basin, were considered as a direct feed for such gasifiers. The average ash content, moisture content and lower heating value were analysed and presented as an average values. Entrained-flow commercial gasifiers can be considered as suitable for the coal slurry feed, however the ash content of coal slurries deposited in impoundments is too high for the direct use as the feed for the gasifiers. The moisture content of slurries calculated on as received basis meets the requirements of entrained-flow slurry feed gasifiers. The content of fines is relatively high which allow to use the slurries in entrained-flow gasifiers.

  14. Waste-heat boiler application for the Vresova combined cycle plant

    Energy Technology Data Exchange (ETDEWEB)

    Vicek, Z. [Energoprojekt Praha, Prague (Czechoslovakia)

    1995-12-01

    This report describes a project proposal and implementation of two combined-cycle units of the Vresova Fuel Complex (PKV) with 2 x 200 MWe and heat supply. Participation of ENERGOPROJECT Praha a.s., in this project.

  15. Nuclear Air-Brayton Combined Cycle Power Conversion Design, Physical Performance Estimation and Economic Assessment

    Science.gov (United States)

    Andreades, Charalampos

    The combination of an increased demand for electricity for economic development in parallel with the widespread push for adoption of renewable energy sources and the trend toward liberalized markets has placed a tremendous amount of stress on generators, system operators, and consumers. Non-guaranteed cost recovery, intermittent capacity, and highly volatile market prices are all part of new electricity grids. In order to try and remediate some of these effects, this dissertation proposes and studies the design and performance, both physical and economic, of a novel power conversion system, the Nuclear Air-Brayton Combined Cycle (NACC). The NACC is a power conversion system that takes a conventional industrial frame type gas turbine, modifies it to accept external nuclear heat at 670°C, while also maintaining its ability to co-fire with natural gas to increase temperature and power output at a very quick ramp rate. The NACC addresses the above issues by allowing the generator to gain extra revenue through the provision of ancillary services in addition to energy payments, the grid operator to have a highly flexible source of capacity to back up intermittent renewable energy sources, and the consumer to possibly see less volatile electricity prices and a reduced probability of black/brown outs. This dissertation is split into six sections that delve into specific design and economic issues related to the NACC. The first section describes the basic design and modifications necessary to create a functional externally heated gas turbine, sets a baseline design based upon the GE 7FB, and estimates its physical performance under nominal conditions. The second section explores the off-nominal performance of the NACC and characterizes its startup and shutdown sequences, along with some of its safety measures. The third section deals with the power ramp rate estimation of the NACC, a key performance parameter in a renewable-heavy grid that needs flexible capacity. The

  16. Modelling of combined cycle power plants using biomass

    Energy Technology Data Exchange (ETDEWEB)

    Jurado, F.; Cano, A. [University of Jaen (Spain). Dept. of Electrical Engineering; Carpio, J. [Universidad Nacional de Educacion a Distancia, Madrid (Spain). Dept. of Electrical and Computer Engineering

    2003-04-01

    The olive tree in Spain can generate large quantities of by-product biomass suitable for gasification. Gasification technologies under development would enable these fuels to be used in gas turbines. Biomass conversion to a clean essentially ash-free form, usually by gasification and purification, is necessary to obtain high efficiency. This paper reports results of detailed full-load performance modelling of cogeneration systems based on gasifier/gas turbine technologies. (Author)

  17. Integrated Gasification Combined Cycle (IGCC) demonstration project, Polk Power Station -- Unit No. 1. Annual report, October 1993--September 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    This describes the Tampa Electric Company`s Polk Power Station Unit 1 (PPS-1) Integrated Gasification Combined Cycle (IGCC) demonstration project which will use a Texaco pressurized, oxygen-blown, entrained-flow coal gasifier to convert approximately 2,300 tons per day of coal (dry basis) coupled with a combined cycle power block to produce a net 250 MW electrical power output. Coal is slurried in water, combined with 95% pure oxygen from an air separation unit, and sent to the gasifier to produce a high temperature, high pressure, medium-Btu syngas with a heat content of about 250 Btu/scf (LHV). The syngas then flows through a high temperature heat recovery unit which cools the syngas prior to its entering the cleanup systems. Molten coal ash flows from the bottom of the high temperature heat recovery unit into a water-filled quench chamber where it solidifies into a marketable slag by-product.

  18. Mineralization of integrated gasification combined-cycle power-station wastewater effluent by a photo-Fenton process.

    Science.gov (United States)

    Durán, A; Monteagudo, J M; San Martín, I; Aguirre, M

    2010-09-01

    The aim of this work was to study the mineralization of wastewater effluent from an integrated-gasification combined-cycle (IGCC) power station sited in Spain to meet the requirements of future environmental legislation. This study was done in a pilot plant using a homogeneous photo-Fenton oxidation process with continuous addition of H(2)O(2) and air to the system. The mineralization process was found to follow pseudo-first-order kinetics. Experimental kinetic constants were fitted using neural networks (NNs). The NNs model reproduced the experimental data to within a 90% confidence level and allowed the simulation of the process for any values of the parameters within the experimental range studied. At the optimum conditions (H(2)O(2) flow rate=120 mL/h, [Fe(II)]=7.6 mg/L, pH=3.75 and air flow rate=1 m(3)/h), a 90% mineralization was achieved in 150 min. Determination of the hydrogen peroxide consumed and remaining in the water revealed that 1.2 mol of H(2)O(2) was consumed per each mol of total organic carbon removed from solution. This result confirmed that an excess of dissolved H(2)O(2) was needed to achieve high mineralization rates, so continuous addition of peroxide is recommended for industrial application of this process. Air flow slightly improved the mineralization rate due to the formation of peroxo-organic radicals which enhanced the oxidation process.

  19. Advanced power cycles and configurations for solar towers: Modeling and optimization of the decoupled solar combined cycle concept

    Science.gov (United States)

    García-Barberena, Javier; Olcoz, Asier; Sorbet, Fco. Javier

    2017-06-01

    CSP technologies are essential to allow large shares of renewables into the grid due to their unique ability to cope with the large variability of the energy resource by means of technically and economically feasible thermal energy storage (TES) systems. However, there is still the need and sought to achieve technological breakthroughs towards cost reductions and increased efficiencies. For this, research on advanced power cycles, like the Decoupled Solar Combined Cycle (DSCC) is, are regarded as a key objective. The DSCC concept is, basically, a Combined Brayton-Rankine cycle in which the bottoming cycle is decoupled from the operation of the topping cycle by means of an intermediate storage system. According to this concept, one or several solar towers driving a solar air receiver and a Gas Turbine (Brayton cycle) feed through their exhaust gasses a single storage system and bottoming cycle. This general concept benefits from a large flexibility in its design. On the one hand, different possible schemes related to number and configuration of solar towers, storage systems media and configuration, bottoming cycles, etc. are possible. On the other, within a specific scheme a large number of design parameters can be optimized, including the solar field size, the operating temperatures and pressures of the receiver, the power of the Brayton and Rankine cycles, the storage capacity and others. Heretofore, DSCC plants have been analyzed by means of simple steady-state models with pre-stablished operating parameters in the power cycles. In this work, a detailed transient simulation model for DSCC plants has been developed and is used to analyze different DSCC plant schemes. For each of the analyzed plant schemes, a sensitivity analysis and selection of the main design parameters is carried out. Results show that an increase in annual solar to electric efficiency of 30% (from 12.91 to 16.78) can be achieved by using two bottoming Rankine cycles at two different

  20. Environmental control implications of generating electric power from coal. Appendix C. Gasification/combined-cycle power generation: comparison of alternative systems. 1977 technology status report. [246 references w. abstracts

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    The technical, economic, and environmental aspects of low-Btu gasification/combined-cycle power-generation (LBG/CCPG) plants are assessed, using available published data. Six base-case plants, based on three different gasifiers and two different coals, are investigated. A representative combined power cycle is selected for analysis, and material and energy balances for the six systems are developed. Emissions of various air pollutants, including sulfur dioxide and nitrogen oxides, and discharge rates of aqueous effluents are also calculated. The costs of electricity produced are derived for the six systems, using estimated plant-investment and operating costs. These costs and the emissions of various pollutants are compared with those for a conventional 500-MWe coal-based power plant using flue-gas cleaning and in compliance with the federal New Source Performance Standards. Finally, the commercialization potential of coal-based combined-cycle plants, based on the technical feasibility of building a first plant in the 1985 period and on economic viability, is evaluated. This evaluation is based on the current status of research and development programs for various components of the combined-cycle plant, such as gas turbines and fuel-gas-cleaning systems, and on the status of the demonstration plant.

  1. Modelling and calculation of combined-cycle power plants with pressurized fluidized bed and with upstream or downstream gas turbines at full load and part load; Modellierung und Berechnung von Kombikraftwerken mit Druckwirbelschicht und vor- sowie nachgeschalteten Gasturbinen bei Voll- und Teillast

    Energy Technology Data Exchange (ETDEWEB)

    Faatz, R.

    1997-12-31

    Owing to their high efficiency, low pollutant emissions and good performance when fuelled with coal, pressurized fluidized-bed combustors have come to play and important role. The performance of processes with pressurized fluidized beds can be enhanced significantly by combining them with gas turbines fuelled with natural gas or coal gas. The report describes several variants of combined cycle processes with pressurized fluidized beds and with gas turbines connected upstream or downstream. The main components, i.e. gas turbine, pressurized fluidized bed, steam turbine and steam cycle are simulated by computer models. For the power plant variants, full-load calculations were carried out to determine the potential efficiency; for the components like gas turbine and pressurized fluidized bed, also part-load calculations were made. It was found that efficiencies of 45-49 % are possible with the investigated variants. Optimisation of the process parameters, efficiencies up to 51.4 % will be possible especially in the range of transition to supercritical steam parameters. (orig.) 68 figs., 14 tabs. [Deutsch] Die Druckwirbelschichtfeuerung hat wegen ihres hohen Wirkungsgrades, ihrer niedrigen Schadstoffemissionen und ihrer Eignung fuer den Brennstoff Kohle eine grosse Bedeutung erlangt. Durch geschickte Kombination mit erdgas- oder kohlegasgefeuerten Gasturbinen laesst sich der Wirkungsgrad von Prozessen mit Druckwirbelschicht betraechtlich steigern. Die vorliegende Arbeit beschreibt verschiedene Schaltungsvarianten von Kombiprozessen mit Druckwirbelschicht, bei denen die Gasturbinen der Wirbelschicht sowohl vorgeschaltet als auch nachgeschaltet sind. Die Hauptkomponenten der Prozesse wie Gasturbine, Druckwirbelschicht, Dampfturbine und Dampfkreislauf werden durch Rechnermodelle simuliert. Fuer die Kraftwerksvarianten wurden Vollastrechnungen zur Ermittlung des Wirkungsgradpotentials, fuer die einzelnen Komponenten wie Gasturbine und Druckwirbelschicht auch

  2. Evaluation of effects of groundwater withdrawals at the proposed Allen combined-cycle combustion turbine plant, Shelby County, Tennessee

    Science.gov (United States)

    Haugh, Connor J.

    2016-08-10

    The Mississippi Embayment Regional Aquifer Study groundwater-flow model was used to simulate the potential effects of future groundwater withdrawals at the proposed Allen combined-cycle combustion turbine plant in Shelby County, Tennessee. The scenario used in the simulation consisted of a 30-year average withdrawal period followed by a 30-day maximum withdrawal period. Effects of withdrawals at the Allen plant site on the Mississippi embayment aquifer system were evaluated by comparing the difference in simulated water levels in the aquifers at the end of the 30-year average withdrawal period and at the end of the scenario to a base case without the Allen combined-cycle combustion turbine plant withdrawals. Simulated potentiometric surface declines in the Memphis aquifer at the Allen plant site were about 7 feet at the end of the 30-year average withdrawal period and 11 feet at the end of the scenario. The affected area of the Memphis aquifer at the Allen plant site as delineated by the 4-foot potentiometric surface-decline contour was 2,590 acres at the end of the 30-year average withdrawal period and 11,380 acres at the end of the scenario. Simulated declines in the underlying Fort Pillow aquifer and overlying shallow aquifer were both less than 1 foot at the end of the 30-year average withdrawal period and the end of the scenario.

  3. Combined Cycle for Power Generation and Refrigeration Using Low Temperature Heat Sources

    OpenAIRE

    Vijay Chauhan; P. Anil Kishan; Sateesh Gedupudi

    2014-01-01

    A combined refrigeration and power cycle, which uses ammonia-water as the working fluid, is proposed by combining Rankine and vapour absorption cycles with an advantage of varying refrigeration capacity to power output ratio. The study investigates the usage of low temperature heat sources for the cycle operation. Results of parametric analysis are presented, which show the scope for optimization. Results of thermodynamic optimization of the cycle for second law efficiency performed using gen...

  4. State estimation of an acid gas removal (AGR) plant as part of an integrated gasification combined cycle (IGCC) plant with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Paul, P.; Bhattacharyya, D.; Turton, R.; Zitney, S.

    2012-01-01

    An accurate estimation of process state variables not only can increase the effectiveness and reliability of process measurement technology, but can also enhance plant efficiency, improve control system performance, and increase plant availability. Future integrated gasification combined cycle (IGCC) power plants with CO2 capture will have to satisfy stricter operational and environmental constraints. To operate the IGCC plant without violating stringent environmental emission standards requires accurate estimation of the relevant process state variables, outputs, and disturbances. Unfortunately, a number of these process variables cannot be measured at all, while some of them can be measured, but with low precision, low reliability, or low signal-to-noise ratio. As a result, accurate estimation of the process variables is of great importance to avoid the inherent difficulties associated with the inaccuracy of the data. Motivated by this, the current paper focuses on the state estimation of an acid gas removal (AGR) process as part of an IGCC plant with CO2 capture. This process has extensive heat and mass integration and therefore is very suitable for testing the efficiency of the designed estimators in the presence of complex interactions between process variables. The traditional Kalman filter (KF) (Kalman, 1960) algorithm has been used as a state estimator which resembles that of a predictor-corrector algorithm for solving numerical problems. In traditional KF implementation, good guesses for the process noise covariance matrix (Q) and the measurement noise covariance matrix (R) are required to obtain satisfactory filter performance. However, in the real world, these matrices are unknown and it is difficult to generate good guesses for them. In this paper, use of an adaptive KF will be presented that adapts Q and R at every time step of the algorithm. Results show that very accurate estimations of the desired process states, outputs or disturbances can be

  5. Integrated gasification combined cycle and the capture of CO{sub 2}: a solution for the mitigation of the CO{sub 2} emissions of coal fired power plants at large scale in the short term?; O ciclo combinado com gaseificacao integrada e a captura de CO{sub 2}: uma solucao para mitigar as emissoes de CO{sub 2} em termeletricas a carvao em larga escala no curto prazo?

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Bettina Susanne

    2010-03-15

    The power sector of many big economies still relies heavily on coal fired plants and emits huge amounts of carbon dioxide (CO{sub 2}). The Integrated Gasification Combined Cycle (IGCC) is an innovative technology which holds advantages over current conventional coal technologies, including higher efficiency, pathway to carbon capture and storage (CCS) and higher product and fuel flexibility. The most critical obstacles for commercialization of IGCC technology are higher costs, lower reliability, and little operating experiences. The present work aims to analyze the maturity and the costs of the IGCC technology, with and without CCS, in order to evaluate its potential to be introduced in the generation fleet at big scale in the short term and, hence, its potential to guarantee the possibility to use coal in the power sector without compromising the effort to reduce CO{sub 2} emissions. The focus of the analysis of the technical viability concentrates strongly on the gasification process, since it the most critical process for the operation of the plant. The cost analysis contains three steps: a revision of cost estimates in scientific literature, a revision of reported cost for actually planned projects and a cost simulation that aims to analyze the influences of assumptions regarding the additional technology risk of IGCC plants. (author)

  6. ``Turbo-KWK `99``. Combined-cycle power stations with gas turbines. Technical meeting; Turbo-KWK `99. Kraft-Waerme-Kopplung mit Gasturbinen. Fachtagung

    Energy Technology Data Exchange (ETDEWEB)

    1999-09-01

    This conference report comprises 18 contributions on the technological success of gas turbines in power generation, e.g.: Maximum power generation efficiency of combined cycle systems, flexibility of power generation, reduction of air pollution, hot gas production for drying processes and environment-friendly cold generation in the pharmaceutical and printing industries. The final contribution presents an outlook to the future.

  7. ``Turbo-KWK `99``. Combined-cycle power stations with gas turbines. Technical meeting; Turbo-KWK `99. Kraft-Waerme-Kopplung mit Gasturbinen. Fachtagung

    Energy Technology Data Exchange (ETDEWEB)

    1999-09-01

    This conference report comprises 18 contributions on the technological success of gas turbines in power generation, e.g.: Maximum power generation efficiency of combined cycle systems, flexibility of power generation, reduction of air pollution, hot gas production for drying processes and environment-friendly cold generation in the pharmaceutical and printing industries. The final contribution presents an outlook to the future.

  8. Power generation from coal and biomass based on integrated gasification combined cycle concept with pre- and post-combustion carbon capture methods

    Energy Technology Data Exchange (ETDEWEB)

    Calin-Cristian Cormos; Ana-Maria Cormos; Serban Agachi [Babes-Bolyai University, Cluj-Napoca (Romania)

    2009-11-15

    Gasification technology is a process in which solid fuel is partially oxidised by oxygen and steam/water to produce a combustible gas called syngas (mainly a mixture of hydrogen and carbon monoxide). Syngas can be used either for power generation or processed to obtain various chemicals (hydrogen, ammonia, methanol, etc.). This article evaluates the possibilities of solid fuel decarbonisation by capturing carbon dioxide resulting from thermo-chemical conversion of solid fuel using gasification. Evaluation is focused on power generation technology using syngas produced by solid fuel gasification (so-called integrated gasification combined cycle IGCC). Case studies analysed in the article are using a mixture of coal and biomass (sawdust) to produce around 400 MW electricity simultaneously with capturing about 90% of the feedstock carbon. Various carbon dioxide capture options (post- and pre-combustion) are compared with situation of no carbon capture in terms of plant configurations, energy penalty, CO{sub 2} emissions, etc. Plant options are modelled using ChemCAD, and simulation results are used to assess the plant performances. Plant flexibility and future improvements are also discussed.

  9. Corrosion behavior of Haynes {sup registered} 230 {sup registered} nickel-based super-alloys for integrated coal gasification combined cycle syngas plants. A plant exposure study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sungkyu; Lee, Jieun; Kang, Suk-Hwan; Lee, Seung-Jong; Yun, Yongseung [Institute for Advanced Engineering (IAE), Gyeonggi-do (Korea, Republic of). Plant Engineering Center; Kim, Min Jung [Sungkyunkwan Univ, Gyeonggi-do (Korea, Republic of). Advanced Materials Technology Research Center

    2015-07-01

    The corrosion behavior of commercially available Haynes {sup registered} 230 {sup registered} nickel-based alloy samples was investigated by exposure to coal-gasifying integrated coal gasification combined cycle pilot plant facilities affiliated with the Institute for Advanced Engineering (2.005 MPa and 160-300 C). The morphological and microstructural analyses of the exposed samples were conducted using scanning electron microscopy and energy-dispersive X-ray spectroscopy analysis on the external surface of the recovered corrosion test samples to obtain information of the corrosion scale. These analyses based on the pre- and post-exposure corrosion test samples combined with thermodynamic Ellingham-Pourbaix stability diagrams provided preliminary insight into the mechanism of the observed corrosion behavior prevailing in the piping materials that connected the particulate removal unit and water scrubber of the integrated coal gasification combined cycle pilot plant. Uniform material wastage was observed after 46 hours of operation, and a preliminary corrosion mechanism was suggested: the observed material waste and corrosion behavior of the Haynes {sup registered} 230 {sup registered} nickel-based alloy samples cut off from the coal syngas integrated coal gasification combined cycle plant were explained by the formation of discontinuous (complex) oxide phases and subsequent chlorine-induced active oxidation under the predominantly reducing environment encountered. This contribution continues the already published studies of the Fe-Ni-Cr-Co alloy Haynes {sup registered} 556 {sup registered}.

  10. Technical and environmental aspects of combined cycle power stations with integrated gasification (CCGI); Aspectos tecnicos y medioambientales de las centrales de ciclo combinado con gasificacion integrada (CCGI)

    Energy Technology Data Exchange (ETDEWEB)

    Beltran Mora, Hector Alejandro; Urias Romero, Francisco [Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2004-06-15

    A description is presented of the operation of the Combined Cycle Power Stations with Integrated Gasification (CCGI) where the use of solid fuels (coal, vacuum residues, petroleum coke, and biomass) or liquids is possible in a thermal power station with the efficiency and many of the own environmental benefits of the combined cycles. The gasification process is analyzed, that is a thermo-chemical process by means of which a fuel that is in solid state or liquid becomes to the gaseous state by means of a partial oxidation and the obtained gas of this process is called synthesis gas (syngas, by its abbreviations in English) that is used in Combined Cycle Power Stations as a substitute for the natural gas. Also the other components of this type of power stations are shown, such as the air separating unit, and some of the modifications that are due to make to adapt a gas turbine so that it uses syngas, and the considerations of their integration with the air separating unit to optimize the operation of the plant are detailed. A comparison of efficiency values of power stations CCGI with the conventional carbon-electric and the power stations of combined cycle that use natural gas is also shown. Finally the emissions of pollutants of SO{sub 2}, NO{sub x} and CO{sub 2} are analyzed. The possibility of using fuels like petroleum coke and vacuum tower residues that are produced in the Cadereyta refinery is studied for the possible construction of a CCGI power station in Mexico. [Spanish] Se presenta la descripcion del funcionamiento de las centrales ciclo combinado con gasificacion integrada (CCGI) donde es posible el uso de combustibles solidos (carbon, residuos de vacio, coque de petroleo, biomasa) o liquidos en una central termica con la eficiencia y muchos de los beneficios ambientales propios de los ciclos combinados. Se analiza el proceso de gasificacion, que es un proceso termoquimico mediante el cual se convierte un combustible que se encuentra en estado solido o

  11. Fossil fuel savings, carbon emission reduction and economic attractiveness of medium-scale integrated biomass gasification combined cycle cogeneration plants

    Directory of Open Access Journals (Sweden)

    Kalina Jacek

    2012-01-01

    Full Text Available The paper theoretically investigates the system made up of fluidized bed gasifier, SGT-100 gas turbine and bottoming steam cycle. Different configurations of the combined cycle plant are examined. A comparison is made between systems with producer gas (PG and natural gas (NG fired turbine. Supplementary firing of the PG in a heat recovery steam generator is also taken into account. The performance of the gas turbine is investigated using in-house built Engineering Equation Solver model. Steam cycle is modeled using GateCycleTM simulation software. The results are compared in terms of electric energy generation efficiency, CO2 emission and fossil fuel energy savings. Finally there is performed an economic analysis of a sample project. The results show relatively good performance in the both alternative configurations at different rates of supplementary firing. Furthermore, positive values of economic indices were obtained. [Acknowledgements. This work was carried out within the frame of research project no. N N513 004036, titled: Analysis and optimization of distributed energy conversion plants integrated with gasification of biomass. The project is financed by the Polish Ministry of Science.

  12. Starting the water treatment system of the 410-MW combined-cycle plant at the Krasnodar cogeneration station

    Science.gov (United States)

    Panteleev, A. A.; Zhadan, A. V.; Gromov, S. L.; Tropina, D. V.; Arkhipova, O. V.

    2012-07-01

    The process diagram of a water treatment plant constructed on the basis of integrated membrane technologies with the use of two-stage reverse osmosis for the PGU-410 power unit at the Krasnodar cogeneration station is presented.

  13. Conventional and intelligent generalized supervisory control for combined cycle generating power stations.; Control supervisiorio generalizado convencional e inteligente para centrales de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez M, Miguel A; Sanchez P, Marino [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Gonzalez Rubio S, Jose L [Cento Nacional de Investigacion y Desarrollo Tecnologico (Cenidet), Cuernavaca, Morelos (Mexico)

    2005-07-01

    Under the expectations of expansion of electric power generation in Mexico, this work exposes the development of a conventional and intelligent generalized supervisory control (CSG) for a combined cycle generation power plant. This one allows to obtain the optimal operation of the power plant through the automatic starting of the generating units and to obtain the maximum possible amount of electrical power in automatic and safe form. For the development of the CSG a control loop by temperature was implemented for the gas turbine system and a control loop by strangled pressure for the gas turbine and a control loop by strangled pressure for the steam turbine. The design of these supervisory systems was made with base in the critical limits on the involved variables of the process: blading average temperature, for the gas turbine (GT) and strangled pressure for the steam turbine (ST) [Spanish] Bajo estas expectativas de expansion de generacion de energia en Mexico, este trabajo expone el desarrollo de un control supervisorio generalizado (CSG) para una central generacion de ciclo combinado. Este permite lograr la operacion optima de la planta a traves del arranque automatico de las unidades generadoras y obtener la maxima cantidad posible de potencia electrica en forma automatica y segura. Para el desarrollo del CSG se implanto un lazo de control por temperatura para el sistema de turbina de gas y un lazo de control por presion estrangulada para la turbina de gas y un lazo de control por presion estrangulada para la turbina de vapor. El diseno de estos sistemas supervisorio se realizo con base en los limites criticos de las variables del proceso involucradas: temperatura promedio de empaletado para la turbina de gas (TG) y presion estrangulada para la turbina de vapor (TV)

  14. Surveillance and monitoring experiences of chemical water-steam cycle in combined-cycle power plants (CCCs in Spanish acronyms) for early diagnosis of failures; Experiencias en vigilancia y seguimiento de parametros de la quimica del ciclo agua-vapor en centrales de ciclo combinado (CCC) para diagnostico precos de fallos

    Energy Technology Data Exchange (ETDEWEB)

    Santaolalla losada, E.

    2010-07-01

    In the present work is made a brief comparative review of the treatments effected in water of the cycle, their purpose, types, monitoring and tracking. Moreover, are described the most important failure mechanisms that can be related to the chemistry of cycle with the aim to establish monitoring guidelines to increase the reliability of the power plant and enable an early diagnosis. (Author)

  15. Study on effective parameter of the triple-pressure reheat combined cycle performance

    OpenAIRE

    Ibrahim Thamir K.; Rahman M.M.

    2013-01-01

    The thermodynamic analyses of the triple-pressure reheat combined cycle gas turbines with duct burner are presented and discussed in this paper. The overall performance of a combined cycle gas turbine power plant is influenced by the ambient temperature, compression ratio and turbine inlet temperature. These parameters affect the overall thermal efficiency, power output and the heat-rate. In this study a thermodynamic model was development on an existing actual combined cycle gas turbin...

  16. Fuel reactivity and release of pollutants and alkali vapours in pressurized combustion for combined cycle power generation

    Energy Technology Data Exchange (ETDEWEB)

    Aho, M.; Haemaelaeinen, J.; Paakkinen, K.; Rantanen, J. [VTT Energy, Jyvaeskylae (Finland); Hernberg, R.; Haeyrinen, V.; Joutsenoja, T. [Tampere Univ. of Technology (Finland). Lab. of Plasma Technology

    1996-12-01

    This project forms a part of the overall Pressurized Power Coal Combustion Project Area (PPFC) which aims at an assessment of the viability and technical merits of pressurized pulverized coal combustion, in an atmosphere of recycled flue gas and oxygen in a coordinated and harmonized programme. The objective of the research at Technical Research Centre of Finland (VTT) and Tampere University of Technology (TUT) is aimed at determining the consequences of solid fuel burning in a mixture of oxygen and recycled flue gases. Combustion conditions of a pressurized entrained flow of pulverized coal and char particles in PEFR are determined with high precision. The effects of experimental parameters on the formation of nitrogen oxides (N{sub 2}O, NO and NO{sub 2}) and gaseous alkali compounds (indicated as NaX(g) and KX(g)) are studied. An effective on-line analysis method for vaporised Na and K compounds was developed. The dependency between particle temperatures and the vaporisation of Na and K was measured with three coals. The results show that alkali removal before gas turbines is always necessary with these coals if combusted in combined cycles. Pressure decreases the formation of NO and has usually no clear effect on the formation of N{sub 2}O. The order of NO/N{sub 2}O ratios correspond to fuel-O/fuel-N ratios. Increase of PO{sub 2} (oxygen concentration) of combustion gas increases the formation of NO{sub 2}. Remarkable concentrations of NO{sub 2} were often measured at high PO{sub 2} at 800-850 deg C. Therefore, NO{sub 2} should be measured from pressurized fluidized bed reactors. Some trends of the formation of NO{sub 2} with coal differ clearly from those with its parent char: N{sub 2}O formation is not strongly temperature dependent with char, and the concentrations of N{sub 2}O formed from char are much lower than those of coal. PO{sub 2} does not effect on the formation of NO from char in the studied range

  17. Exergy analysis of an integrated solar combined cycle system

    Energy Technology Data Exchange (ETDEWEB)

    Baghernejad, A.; Yaghoubi, M. [Engineering School, Shiraz University, Shiraz (Iran)

    2010-10-15

    Exergetic analysis has become an integral part of thermodynamic assessment of any power generation system. Energy and exergy studies for power plants optimum design and for combined chemical industries received much attention recently. An Integrated Solar Combined Cycle System (ISCCS) is proposed as a means of integrating a parabolic trough solar thermal plant with modern combined cycle power plants. In this study attempt will be made to analyze the Integrated Solar Combined Cycle in Yazd, Iran using design plant data. Energy and exergy analysis for the solar field and combined cycle is carried out to assess the plant performance and pinpoint sites of primary exergy destruction. Exergy destruction throughout the plant is quantified and illustrated using an exergy flow diagram, and compared to the energy flow diagram. The causes of exergy destruction in the plant include: losses in combustor, collector, heat exchangers, and pump and turbines which accounts for 29.62, 8.69, 9.11 and 8% of the total exergy input to the plant, respectively. Exergetic efficiencies of the major plant components are determined in an attempt to assess their individual performances. (author)

  18. Release and sorption of alkali metals in coal fired combined cycle power systems; Freisetzung und Einbindung von Alkalimetallverbindungen in kohlebefeuerten Kombikraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Michael

    2009-07-01

    Coal fired combined cycle power systems will be a sufficient way to increase the efficiency of coal combustion. However, combined cycle power systems require a reliable hot gas cleanup. Especially alkali metals, such as sodium and potassium, can lead to hot corrosion of the gas turbine blading if they condensate as sulphates. The actual work deals with the release and sorption of alkali metals in coal fired combined cycle power systems. The influence of coal composition, temperature and pressure on the release of alkali species in coal combustion was investigated and the relevant release mechanisms identified. Alumosilicate sorbents have been found that reduce the alkali concentration in the hot flue gas of the Circulating Pressurized Fluidized Bed Combustion 2{sup nd} Generation (CPFBC 2{sup nd} Gen.) at 750 C to values sufficient for use in a gas turbine. Accordingly, alumosilicate sorbents working at 1400 C have been found for the Pressurized Pulverized Coal Combustion (PPCC). The sorption mechanisms have been identified. Thermodynamic calculations were performed to upscale the results of the laboratory experiments to conditions prevailing in power systems. According to these calculations, there is no risk of hot corrosion in both processes. Furthermore, thermodynamic calculations were performed to investigate the behaviour of alkali metals in an IGCC with integrated hot gas cleanup and H{sub 2} membrane for CO{sub 2} sequestration. (orig.)

  19. Fuel gas production from renewable biomass in a circulating fluidized bed as a bases for zero-CO{sub 2} power generation in a combined-cycle power plant; Brenngaserzeugung aus nachwachsenden Biomassen in der zirkulierenden Wirbelschicht als Grundlage fuer eine CO{sub 2}-neutrale Stromerzeugung in einem GUD Kraftwerk

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, J.; Loeffler, J.; Hirschfelder, H. [Lurgi Energie und Umwelt GmbH, Frankfurt am Main (Germany)

    1996-12-31

    A pilot circulating fluidized bed plant in the range of 1.7 MW{sub th} has been operated successfully with fossil fuels, residues, wood bark and wood chips, reet grass and sorghum pellets. Depending on the specifications for product gas and fuel quality, air, oxygen-enriched air or oxygen/steam mixtures are used as gasification agents in the gas generator. (orig) [Deutsch] In einer ZWS-Pilotanlage mit ca. 1.7 MW thermischer Leistung wurden bisher ausser fossilen und Abfallbrennstoffen auch Rindenabfaelle, Holzschnitzel, Schilfgras und Sorghumpellets erfolgreich zur Brenngaserzeugung eingesetzt. Entsprechend den Anforderungen an das Produktgas und der Brennstoffqualitaet wird Luft, sauerstoffangereicherte Luft oder Sauerstoff/Dampfgemische als Vergasungsmittel im ZWS-Gaserzeuger eingesetzt. (orig)

  20. Studies of an extensively axisymmetric rocket based combined cycle (RBCC) engine powered single-stage-to-orbit (SSTO) vehicle

    Science.gov (United States)

    Foster, Richard W.; Escher, William J. D.; Robinson, John W.

    1989-01-01

    The present comparative performance study has established that rocket-based combined cycle (RBCC) propulsion systems, when incorporated by essentially axisymmetric SSTO launch vehicle configurations whose conical forebody maximizes both capture-area ratio and total capture area, are capable of furnishing payload-delivery capabilities superior to those of most multistage, all-rocket launchers. Airbreathing thrust augmentation in the rocket-ejector mode of an RBCC powerplant is noted to make a major contribution to final payload capability, by comparison to nonair-augmented rocket engine propulsion systems.

  1. Technical and financial analysis of combined cycle gas turbine

    Directory of Open Access Journals (Sweden)

    Khan Arshad Muhammad

    2013-01-01

    Full Text Available This paper presents technical and financial models which were developed in this study to predict the overall performance of combined cycle gas turbine plant in line with the needs of independent power producers in the liberalized market of power sector. Three similar sizes of combined cycle gas turbine power projects up to 200 Megawatt of independent power producers in Pakistan were selected in-order to develop and drive the basic assumptions for the inputs of the models in view of prevailing Government of Pakistan’s two components of electricity purchasing tariff that is energy purchase price and capacity purchase price at higher voltage grid station terminal from independent power producers. The levelized electricity purchasing tariff over life of plant on gaseous fuel at 60 percent plant load factor was 6.47 cent per kilowatt hour with energy purchase price and capacity purchase prices of 3.54 and 2.93 cents per kilowatt hour respectively. The outcome of technical models of gas turbine, steam turbine and combined cycle gas turbine power were found in close agreement with the projects under consideration and provides opportunity of evaluation of technical and financial aspects of combined cycle power plant in a more simplified manner with relatively accurate results. At 105 Celsius exit temperature of heat recovery steam generator flue gases the net efficiency of combined cycle gas turbine was 48.8 percent whereas at 125 Celsius exit temperature of heat recovery steam generator flue gases it was 48.0 percent. Sensitivity analysis of selected influential components of electricity tariff was also carried out.

  2. Internalization of externalities in the generation costs of electric power centrals of carbon, combined cycle and nuclear; Internalizacion de externalidades en los costos de generacion de centrales electricas de carbon, ciclo combinado y nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Gomez R, M.C. [Universidad Anahuac del Norte (Mexico); Palacios H, J.; Ramirez S, R.; Alonso V, G. [ININ, Carretera Mexico-Toluca Km. 36.5 Ocoyoacac 52750 Edo. de Mexico (Mexico)]. e-mail: fgrivera@avantel.net

    2007-07-01

    The technologies of electric power generation that use fossil fuels, they incorporate in the Even Total Cost of Generation (CTNG) only the direct costs of generation (investment, fuel costs, operation costs and maintenance). nevertheless, the nuclear energy incorporates besides the direct costs, the externalities that causes to the human health and the environment. In this work the CTNG is calculated that incorporates the externalities, of a thermoelectric power station of coal, a plant of combined cycle and of four reactors of Generation III (ABWR, ACR, AP1000 and EPR). The obtained results show that the nuclear power station has smaller CTNG that the technologies that use fossil fuels. It is important to stand out that they are only considering the externalities of the stage of electricity generation, for what the mining phase and transport of the fuel toward the central are not considered in the present document. (Author)

  3. Kansas Power Plants

    Data.gov (United States)

    Kansas Data Access and Support Center — The Kansas Power Plants database depicts, as point features, the locations of the various types of power plant locations in Kansas. The locations of the power plants...

  4. H gas turbine combined cycle

    Energy Technology Data Exchange (ETDEWEB)

    Corman, J. [General Electric Co., Schenectady, NY (United States)

    1995-10-01

    A major step has been taken in the development of the Next Power Generation System - {open_quotes}H{close_quotes} Technology Combined Cycle. This new gas turbine combined-cycle system increases thermal performance to the 60% level by increasing gas turbine operating temperature to 1430 C (2600 F) at a pressure ratio of 23 to 1. Although this represents a significant increase in operating temperature for the gas turbine, the potential for single digit NOx levels (based upon 15% O{sub 2}, in the exhaust) has been retained. The combined effect of performance increase and environmental control is achieved by an innovative closed loop steam cooling system which tightly integrates the gas turbine and steam turbine cycles. The {open_quotes}H{close_quotes} Gas Turbine Combined Cycle System meets the goals and objectives of the DOE Advanced Turbine System Program. The development and demonstration of this new system is being carried out as part of the Industrial/Government cooperative agreement under the ATS Program. This program will achieve first commercial operation of this new system before the end of the century.

  5. Solid-Fueled Pressurized Chemical Looping with Flue-Gas Turbine Combined Cycle for Improved Plant Efficiency and CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Kunlei; Chen, Liangyong; Zhang, Yi; Richburg, Lisa; Simpson, James; White, Jay; Rossi, Gianalfredo

    2013-12-31

    The purpose of this document is to report the final result of techno-economic analysis for the proposed 550MWe integrated pressurized chemical looping combustion combined cycle process. An Aspen Plus based model is delivered in this report along with the results from three sensitivity scenarios including the operating pressure, excess air ratio and oxygen carrier performance. A process flow diagram and detailed stream table for the base case are also provided with the overall plant energy balance, carbon balance, sulfur balance and water balance. The approach to the process and key component simulation are explained. The economic analysis (OPEX and CAPX) on four study cases via DOE NETL Reference Case 12 are presented and explained.

  6. Simulación de Plantas de Cogeneración de Ciclo Combinado usando ASPEN® Simulation of Combined Cycle Cogeneration Plants using ASPEN®

    Directory of Open Access Journals (Sweden)

    S.G. Guerra

    2005-01-01

    Full Text Available El objetivo de este trabajo fue generar una estrategia para el diseño de plantas de cogeneración de ciclo combinado, basada en el uso del simulador ASPEN®. La estrategia comprende la simulación, así como la definición de todas las variables clave del proceso. Como caso de estudio, se consideró satisfacer la demanda real de vapor y electricidad en una refinería usando un esquema de cogeneración de ciclo combinado. Aspectos relevantes de la situación actual de esta tecnología tal como el cálculo del punto de rocío ácido, para restringir la temperatura de los gases de salida, fueron considerados en el modelo. Se revisaron tres esquemas para determinar la mejor opción para el caso de estudio. Se concluye que la estrategia aplicada en este análisis puede generalizarse a otros casos y podría ser aplicada en el diseño futuro de plantas de cogeneración en MéxicoThe objective of this work was to generate a strategy for combined cycle cogeneration plant design based on the ASPEN® process simulator. The approach included process simulation as well as definition of all key variables. Satisfaction of real vapor and electricity demands in a refinery was considered as a case study, using a scheme of combined cycle cogeneration. Considered in the model were the outstanding aspects of the state of the art for this technology, such as the calculation of the dew acid point to restrict the temperature of exhaust gases. Three schemes were analyzed to determine the best option for the case under study. It was concluded that this approach could be extended to other cases and could be applied to the future design of cogeneration plants in Mexico.

  7. Integrated Gasifier Combined Cycle Plant with Integrated CO2 – H2S Removal: Performance Analysis, Life Cycle Assessment and Exergetic Life Cycle Assessment

    Directory of Open Access Journals (Sweden)

    Lidia Lombardi

    2002-03-01

    Full Text Available

    The aim of this study is to assess the possibility of reducing CO2 emissions from an Integrated Gasifier Combined Cycle plant, accounting for the entire life cycle.

    With respect to the basic scheme of a conventional Integrated Gasification Combined Cycle - which already includes H2S removal - a shift reaction section followed by CO2 chemical absorption have been added, before the syngas combustion, in order to obtain a clean and H2-rich synthesis gas.

    The proposed plant reaches 38.8 % efficiency vs. 46.4 % efficiency of the corresponding IGCC without CO2 removal. The main reason for the efficiency reduction is the complexity due to the addition of shift and CO2 removal sections and, hence, the related losses in the complex heat recovery process.

    From LCA results, a substantial decrease in the carbon dioxide total production, due to the applied removal technology, is highlighted. In fact, the CO2 equivalent production in the life cycle, per energy unit, is one order of magnitude lower with respect to the parent IGCC.

    Moreover, the major contribution to CO2 production comes from operation/maintenance phase; likely, in the case of Exergetic Life Cycle Assessment: the major exergy destruction - in term of MJ of destroyed exergy per functional unit - comes from operation/maintenance, which is two orders of magnitude greater than the contributions of the other phases.

    The whole cycle has been simulated by means of Aspen Plus 10.1-0.

  8. Combined-cycle power stations using ``clean-coal-technologies``: Thermodynamic analysis of full gasification vs. fluidized bed combustion with partial gasification

    Energy Technology Data Exchange (ETDEWEB)

    Lozza, G.; Chiesa, P. [Politecnico di Milano, Milan (Italy). Dept. of Energetics; DeVita, L. [Eniricerche, Milan (Italy)

    1994-12-31

    A novel class of power plants for clean conversion of coal into power has been recently proposed, based on the concept of partial coal gasification and fluidized-bed combustion of unconverted char from gasification. This paper focuses on the thermodynamic aspects of these plants, in comparison with full gasification cycles, assessing their performance on the basis of a common advanced power plant technology level. Several plant configurations are considered, including pressurized or atmospheric fluidized-bed, air- or steam-cooled, with different carbon conversion in the gasifier. The calculation method, used for reproducing plant energy balances and for performance prediction, is described in the paper. A complete second-law analysis is carried out, pointing out the efficiency loss breakdown for both technologies. Results show that partial gasification plants can achieve efficiencies consistently higher than IGCC, depending on plant configuration and carbon conversion, making this solution a viable and attractive option for efficient coal utilization.

  9. Combined-cycle power stations using clean-coal technologies: Thermodynamic analysis of full gasification versus fluidized bed combustion with partial gasification

    Energy Technology Data Exchange (ETDEWEB)

    Lozza, G.; Chiesa, P. [Politecnico di Milano, Milan (Italy). Dept. of Energetics; DeVita, L. [Eniricerche, Milan (Italy)

    1996-10-01

    A novel class of power plants for clean conversion of coal into power has been recently proposed, based on the concept of partial coal gasification and fluidized-bed combustion of unconverted char from gasification. This paper focuses on the thermodynamic aspects of these plants, in comparison with full gasification cycles, assessing their performance on the basis of a common advanced power plant technology level. Several plant configurations are considered, including pressurized or atmospheric fluidized-bed, air- or steam-cooled, with different carbon conversion in the gasifier. The calculation method, used for reproducing plant energy balances and for performance prediction, is described in the paper. A complete second-law analysis is carried out, pointing out the efficiency loss breakdown for both technologies. Results show that partial gasification plants can achieve efficiencies consistently higher than IGCC, depending on plant configuration and carbon conversion, making this solution a viable and attractive option for efficient coal utilization.

  10. Prospects for Geothermal Energy Conversion through a Hybrid Combined Cycle Power Plant

    Directory of Open Access Journals (Sweden)

    L. Böszörményi

    2003-01-01

    Full Text Available The demand for more intensive utilization of energy sources is getting more important with the forthcoming European Union membership of the Slovak Republic. Lack of resources and poor exploitaition of available resources can be a very difficult problem for energy policy. It is important to use technical solutions to minimize or eliminate this problem. The most beneficial progress could be achieved in the Košice basin where geothermal energy could have effective and multi-purpose use.

  11. Assessment of CCGT power plants - Comparison between new and repowering

    Energy Technology Data Exchange (ETDEWEB)

    Giger, Francois; Lehougre, Jean-Francois [EDF/DPIT, Staint Denis (France)

    2013-04-01

    Since 2007, EDF has repowered the Martigues conventional oil-fired power plant and erected two 460 MWe combined cycle units with natural gas firing. The first unit went on line in 2012, the second is to be connected to the grid in 2013. A completely new 440 MWe combined cycle power plant was built at the Blenod site which went into operation in the autumn of 2011. Both projects were realised by EDF-in-house engineering teams. Post-building analysis confirmed the economic benefit anticipated at basic design stage of the repowering approach compared to a green field construction.

  12. HIGH EFFICIENCY FOSSIL POWER PLANT (HEFPP) CONCEPTUALIZATION PROGRAM

    Energy Technology Data Exchange (ETDEWEB)

    J.L. Justice

    1999-03-25

    This study confirms the feasibility of a natural gas fueled, 20 MW M-C Power integrated pressurized molten carbonate fuel cell combined in a topping cycle with a gas turbine generator plant. The high efficiency fossil power plant (HEFPP) concept has a 70% efficiency on a LHV basis. The study confirms the HEFPP has a cost advantage on a cost of electricity basis over the gas turbine based combined cycle plants in the 20 MW size range. The study also identifies the areas of further development required for the fuel cell, gas turbine generator, cathode blower, inverter, and power module vessel. The HEFPP concept offers an environmentally friendly power plant with minuscule emission levels when compared with the combined cycle power plant.

  13. MCFC power plant with CO{sub 2} separation

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Noboru [Ishikawajima-Harima Heavy Industries Co., Ltd., Tokyo (Japan)

    1996-12-31

    Fuel cell power plant has been developed for many years with expectation of high system efficiency. In the meantime the gas turbine combined cycle has shown its considerable progress in improving system efficiency. Fuel cell power plant will no longer be attractive unless it exceeds the gas turbine combined cycle at least in the system efficiency. It is said CO{sub 2} separation could improve the efficiency of fuel cell power plant. IHI has developed the CO{sub 2} separator for fuel cell power plant. This study describes that the CO{sub 2} separator can increase the efficiency of the molten carbonate fuel cell (MCFC) power plant by 5% and the expected efficiency reaches 63 % in HHV basis.

  14. Biomass Gasification Combined Cycle

    Energy Technology Data Exchange (ETDEWEB)

    Judith A. Kieffer

    2000-07-01

    Gasification combined cycle continues to represent an important defining technology area for the forest products industry. The ''Forest Products Gasification Initiative'', organized under the Industry's Agenda 2020 technology vision and supported by the DOE ''Industries of the Future'' program, is well positioned to guide these technologies to commercial success within a five-to ten-year timeframe given supportive federal budgets and public policy. Commercial success will result in significant environmental and renewable energy goals that are shared by the Industry and the Nation. The Battelle/FERCO LIVG technology, which is the technology of choice for the application reported here, remains of high interest due to characteristics that make it well suited for integration with the infrastructure of a pulp production facility. The capital cost, operating economics and long-term demonstration of this technology area key input to future economically sustainable projects and must be verified by the 200 BDT/day demonstration facility currently operating in Burlington, Vermont. The New Bern application that was the initial objective of this project is not currently economically viable and will not be implemented at this time due to several changes at and around the mill which have occurred since the inception of the project in 1995. The analysis shows that for this technology, and likely other gasification technologies as well, the first few installations will require unique circumstances, or supportive public policies, or both to attract host sites and investors.

  15. Power Plant Cycling Costs

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, N.; Besuner, P.; Lefton, S.; Agan, D.; Hilleman, D.

    2012-07-01

    This report provides a detailed review of the most up to date data available on power plant cycling costs. The primary objective of this report is to increase awareness of power plant cycling cost, the use of these costs in renewable integration studies and to stimulate debate between policymakers, system dispatchers, plant personnel and power utilities.

  16. The Development of Coke Carried—Heat Gasification Coal—Fired Combined Cycle

    Institute of Scientific and Technical Information of China (English)

    LiZhao; XiangdongXu

    1999-01-01

    Carried-Heat Partial Gasification Combined cycle is a novel combined cycle which was proposed by Thermal Engineering Department of Tsinghua University in 1992,The idea of the system comes from the situation that the efficiency of the power plants in china is much lower than that of the advanced countries,but the coal consumption is much higher,which brings about the waste of primary energy resources and the pollution of the environment.With the deep study of the gasification technology,Coke Carried-Heat Gasification Coal-Fired Combined Cycle,as the improved system,came into birth in 1996 based on the partial gasification one,At the end of 1997,a new cycle scheme similar to IGCC was created.This paper focuses on several classes combined cycle put forward by Tsinghua University,depending on the plant configuration and carbon conversion,making the solution a viable and attractive option for efficient coal utilization.

  17. Diffuse control of gas turbines in power stations of combined cycle; Contral difuso de turbinas de gas en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez P, Marino; Garduno R, Raul; De Lara J, Salvadror; Castelo C, Luis [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    In this article the application of the technology of the fuzzy logic to the control of gas turbines is presented in order to evaluate it in one of the most difficult processes and with stricter control requirements that exist in the electrical generation industry. For being important for the generation electrical sector, given their use in Comision Federal de Electricidad (CFE), the first selected prototype was the gas turbines model W501 of Westinghouse, installed in the of combined cycle power stations of Dos Bocas, Veracruz, Gomez Palacio, Durango and Tula, Hidalgo, Mexico. The second selected prototype was the one of the turbo gas units type 5001 (that applies to the GE 5001 models and Westinghouse of series 191 and 251). Based on the analysis of the performance of the system of conventional control previously made, the controllers of speed and generation of electrical power were selected to be replaced by diffuse controllers. [Spanish] En este articulo se presenta la aplicacion de la tecnologia de la logica difusa al control de turbinas de gas con el proposito de evaluarla en uno de los procesos mas dificiles y con requerimientos mas estrictos de control que existen en la industria de generacion electrica. Por ser importantes para el sector electrico de generacion, dada su utilizacion en Comision Federal de Electricidad (CFE), el primer prototipo seleccionado fueron las turbinas de gas modelo W501 de Westinghouse, instaladas en la central de ciclo combinado de Dos Bocas, Veracruz, Gomez Palacio, Durango y Tula, Hidalgo, Mexico. El segundo prototipo seleccionado fue el de unidades turbogas tipo 5001 (que aplica a los modelos GE 5001 y Westinghouse de la serie 191 y 251). Basados en el analisis del desempeno del sistema de control convencional realizado previamente, los controladores de velocidad y de generacion de potencia electrica fueron seleccionados para ser sustituidos por controladores difusos.

  18. DIRECT FUEL/CELL/TURBINE POWER PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Hossein Ghezel-Ayagh

    2004-05-01

    This report includes the progress in development of Direct FuelCell/Turbine{reg_sign} (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T power system is based on an indirectly heated gas turbine to supplement fuel cell generated power. The DFC/T power generation concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, 60% on coal gas, minimal emissions, simplicity in design, direct reforming internal to the fuel cell, reduced carbon dioxide release to the environment, and potential cost competitiveness with existing combined cycle power plants. FCE successfully completed testing of the pre-alpha DFC/T hybrid power plant. This power plant was constructed by integration of a 250kW fuel cell stack and a microturbine. The tests of the cascaded fuel cell concept for achieving high fuel utilizations were completed. The tests demonstrated that the concept results in higher power plant efficiency. Also, the preliminary design of a 40 MW power plant including the key equipment layout and the site plan was completed.

  19. Application of Gas-Steam Combined Cycle Power Generation in Offshore Oil Engineering%燃蒸联合循环发电在海油工程的应用分析

    Institute of Scientific and Technical Information of China (English)

    张琦; 李晖; 白云

    2015-01-01

    中海石油(中国)有限公司在某海上油气田开发工程中首次引入燃-蒸联合循环发电技术,充分利用陆上终端已建燃气透平发电机排放的高温烟气,组成燃-蒸联合循环发电系统,将燃气轮机排烟余热进行回收。提升了原有电站的效能,并且实现节能、减排、保护环境,符合国家政策,经济合理。%Gas-steam combined cycle power generation technology was first introduced to a development engineering of offshore oil and gas field by CNOOC. Making extensive use of high temperature flue emitted by the gas turbine generator at the onshore terminal, the technology has recycled the gas turbine exhaust and formed a gas-steam cycle power generation system. As a result, the efficiency of the original power plant is improved and energy saving is achieved. In addition, emission reduction and environmental protection are in line with the national policy.

  20. Technology qualification for IGCC power plant with CO2 Capture

    OpenAIRE

    Baig, Yasir

    2011-01-01

    Summary:This thesis presents the technology qualification plan for the integrated gasification combined cycle power plant (IGCC) with carbon dioxide capture based on DNV recommendations. Objectives of the thesis work were development of a qualification plan, heat balance, material balance and performance characteristics for IGCC with CO2 capture. GT PRO software by thermoflow was used for the development of heat balance, material balance and performance characteristics of power plant.IGCC wit...

  1. Technological tendencies for the improvement of the performance of combined cycle power stations; Tendencias tecnologicas para el mejoramiento del desempeno de centrales de cilco combinado

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez P, Marino; Garduno R, Raul; Chavez T, Rafael [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    In this article are dealt some the aspects that have turned the combined cycle generating power stations (CCGPS) into the dominant way for the electrical generation in the world. In the first part it is presented the plan of expansion of the national electrical generation and similar information that the U.S.A. has for the CCGPS, which will give an idea of the importance and the impact that has this technology at the moment. The basic characteristics that are necessary to specify in order to satisfy the environmental and operation requirements, and the available technologies to increase the global efficiency of the CCGPS are also exposed. Finally it describes the evolution of the technology of control for CCGPS developed in the Gerencia de Control e Instrumentacion (GCI), as well as the capacities available to support the electrical sector in this technological discipline. [Spanish] En este articulo se tratan algunos de los aspectos que han convertido a las centrales de generacion de ciclo combinado (CGCC) en el modo dominante para la generacion electrica en el mundo. En la primera parte se presenta el plan de expansion de la generacion electrica nacional e informacion similar que los EE.UU. tienen para las CGCC, lo que dara una idea de la importancia y del impacto que tiene actualmente esta tecnologia. Se exponen tambien las caracteristicas principales que es necesario especificar a fin de satisfacer los requerimientos ambientales y de operacion, y las tecnologias disponibles para incrementar la eficiencia global de las CGCC. Finalmente se describe la evolucion de la tecnologia de control para CGCC desarrollada en la Gerencia de Control e Instrumentacion (GCI), asi como las capacidades disponibles para apoyar al sector electrico en esta disciplina tecnologica.

  2. DESIGN OF COMBINED CYCLE GENERATION SYSTEM WITH HIGH TEMPERATURE FUEL CELL AND STEAM TURBINE

    Institute of Scientific and Technical Information of China (English)

    Yu Lijun; Yuan Junqi; Cao Guangyi

    2003-01-01

    For environment protection and high efficiency, development of new concept power plant has been required in China. The fuel cell is expected to be used in a power plant as a centralized power station or distributed power plant. It is a chemical power generation device that converts the energy of a chemical reaction directly into electrical energy and not limited by Carnot cycle efficiency. The molten carbonate fuel cell (MCFC) power plant has several attractive features I.e. High efficiency and lower emission of Nox and Sox. A combined cycle generation system with MCFC and steam turbine is designed. Its net electrical efficiency LHV is about 55%.

  3. A combined cycle engine test facility

    Energy Technology Data Exchange (ETDEWEB)

    Engers, R.; Cresci, D.; Tsai, C. [General Applied Science Laboratories Inc., Ronkonkoma, NY (United States)

    1995-09-01

    Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in which the propulsive force was generated by rocket only, the ramjet only and simultaneous rocket and ramjet power (combined cycle) to evaluate combustor operation over the entire engine cycle. The test facility provides simulation over the flight Mach number range of 0 to 8 and at various trajectories. The capabilities of the combined cycle engine test facility are presented.

  4. Simulators predict power plant operation

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, R.

    2002-07-01

    Mix the complexity of a new construction or major retrofit project with today's 'do more with less', a pinch of 'personnel inexperience,' and a dash of 'unintended consequences', and you have got a recipe for insomnia. Advanced simulation tools, however, can help you wring out your design train your operators before the first wire is terminated and just may be get a good night's rest. The article describes several examples of uses of simulation tools. Esscor recently completed a simulation project for a major US utility exploring the potential for furnace/duct implosion that could result from adding higher volumetric flow induced-draft fans and selective catalytic reduction to a 650-MW coal-fired plant. CAF Electronics Inc. provided a full-scope simulator for Alstom's KA24-1 combined-cycle power plant in Paris, France. Computational fluid dynamics (CFD) tools are being used by the Gas Technology Institute to simulate the performance of the next generation of pulverized coal combustors. 5 figs.

  5. Nuclear Power Plants. Revised.

    Science.gov (United States)

    Lyerly, Ray L.; Mitchell, Walter, III

    This publication is one of a series of information booklets for the general public published by the United States Atomic Energy Commission. Among the topics discussed are: Why Use Nuclear Power?; From Atoms to Electricity; Reactor Types; Typical Plant Design Features; The Cost of Nuclear Power; Plants in the United States; Developments in Foreign…

  6. Power plant chemical technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    17 contributions covering topies of fossil fuel combustion, flue gas cleaning, power plant materials, corrosion, water/steam cycle chemistry, monitoring and control were presented at the annual meeting devoted to Power Plant Chemical Technology 1996 at Kolding (Denmark) 4-6 September 1996. (EG)

  7. The Kuroshio power plant

    CERN Document Server

    Chen, Falin

    2013-01-01

    By outlining a new design or the Kuroshio power plant, new approaches to turbine design, anchorage system planning, deep sea marine engineering and power plant operations and maintenance are explored and suggested. The impact on the local environment, particularly in the face of natural disasters, is also considered to provide a well rounded introduction to plan and build a 30MW pilot power plant. Following a literature review, the six chapters of this book propose a conceptual design by focusing on the plant's core technologies and establish the separate analysis logics for turbine design and

  8. Economics of hybrid photovoltaic power plants

    Energy Technology Data Exchange (ETDEWEB)

    Breyer, Christian

    2012-08-16

    coal fired power plants, wind power, solar thermal power (STEG) and hydro power plants. For the 2010s, detailed global demand curves are derived for hybrid PV-Fossil power plants on a per power plant, per country and per fuel type basis. The fundamental technical and economic potentials for hybrid PV-STEG, hybrid PV-Wind and hybrid PV-Hydro power plants are considered. The global resource availability for PV and wind power plants is excellent, thus knowing the competitive or complementary characteristic of hybrid PV-Wind power plants on a local basis is identified as being of utmost relevance. The complementarity of hybrid PV-Wind power plants is confirmed. As a result of that almost no reduction of the global economic PV market potential need to be expected and more complex power system designs on basis of hybrid PV-Wind power plants are feasible. The final target of implementing renewable power technologies into the global power system is a nearly 100% renewable power supply. Besides balancing facilities, storage options are needed, in particular for seasonal power storage. Renewable power methane (RPM) offers respective options. A comprehensive global and local analysis is performed for analysing a hybrid PV-Wind-RPM combined cycle gas turbine power system. Such a power system design might be competitive and could offer solutions for nearly all current energy system constraints including the heating and transportation sector and even the chemical industry. Summing up, hybrid PV power plants become very attractive and PV power systems will very likely evolve together with wind power to the major and final source of energy for mankind.

  9. Nuclear power plant maintainability.

    Science.gov (United States)

    Seminara, J L; Parsons, S O

    1982-09-01

    In the mid-1970s a general awareness of human factors engineering deficiencies associated with power plant control rooms took shape and the Electric Power Research Institute (EPRI) awarded the Lockheed Corporation a contract to review the human factors aspects of five representative operational control rooms and their associated simulators. This investigation revealed a host of major and minor deficiencies that assumed unforeseen dimensions in the post- Three Mile Island accident period. In the course of examining operational problems (Seminara et al, 1976) and subsequently the methods for overcoming such problems (Seminara et al, 1979, 1980) indications surfaced that power plants were far from ideal in meeting the needs of maintenance personnel. Accordingly, EPRI sponsored an investigation of the human factors aspects of power plant maintainability (Seminara, 1981). This paper provides an overview of the maintainability problems and issues encountered in the course of reviewing five nuclear power plants.

  10. Large Combined Heat and Power Plants for Sustainable Energy System

    DEFF Research Database (Denmark)

    Lund, Rasmus Søgaard; Mathiesen, Brian Vad

    . CHP (combined heat and power) plants in Denmark will change their role from base load production to balancing the fluctuation in renewable energy supply, such as wind power and at the same time they have to change to renewable energy sources. Some solutions are already being planned by utilities...... in Denmark; conversion of pulverised fuel plants from coal to wood pellets and a circulating fluidised bed (CFB) plant for wood chips. From scientific research projects another solution is suggested as the most feasible; the combined cycle gas turbine (CCGT) plant. In this study a four scenarios...

  11. Isobaric gas and steam. Compressed air storage power plant with heat storage system; Isobares GuD. Druckluftspeicherkraftwerk mit Waermespeicher

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Lasse; Leithner, Reinhard; Qi, Dawei [Technische Univ. Braunschweig (Germany). Inst. fuer Waerme- und Brennstofftechnik; Grote, Wolfgang; Kastsian, Darya; Moennigmann, Martin [Bochum Univ. (Germany). Lehrstuhl fuer Regelungstechnik und Systemtheorie

    2011-07-01

    The ISACOAST-CC (Isobaric Adiabatic Compressed Air Energy Storage - Combinde Cycle) is a innovative combination of combined cycle power plant, compressed air store and heat store. First calculations show that a storage efficiency of 80 % could be achieved.

  12. Automatic system of tests for control equipment in combined cycle power stations; Sistema automatico de pruebas para equipos de control en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez M, Miguel A; Flores L, Zenon; Delgadillo V, Miguel A; Gutierrez A, Ruben [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    This article deals on the Automatic System of Tests, denominated PROBADOR, used by the Gerencia de Control e Instrumentation (GCI) of the Instituto de Investigaciones Electricas (IIE)for the accomplishment of dynamic tests in laboratory, to the systems of acquisition and control developed with the electronic line SAC-IIE that are installed in the Thermoelectric Power station of Combined Cycle (CTCC) of Dos Bocas, Veracruz and Gomez Palacio, Durango, Mexico. Also the architecture, the functions that are carried out in the equipment of the System of Acquisition and control (SAC) and in the personal computer (PC) that conforms it are described, as well as the methodology used for the development of the tests. The PC constitutes Interface Man-Machine (IMM) and in the SAC equipment the simulation of the processes is made (by means of the execution of algebraic-differential equations) in the compressor, combustion chamber, gas turbine, heat recuperators, steam turbines and condenser equipment that integrate a CTCC. The equations that are used are based in the thermodynamics, flow dynamics and heat transfer; they become attached to the real process with a margin of error that is estimated in 10%. Finally, the tendencies of the PROBADOR and the technical and economic advantages are described that it has provided for the improvement in the performance of the control systems, before different situations, with no need to have the real process. [Spanish] Este articulo versa sobre el Sistema Automatico de Pruebas, denominado PROBADOR, utilizado por la Gerencia de Control e Instrumentacion (GCI) del Instituto de Investigaciones Electricas para la realizacion de pruebas dinamicas en laboratorio, a los sistemas de adquisicion y control desarrollado con la linea electronica SAC-IIE que estan instalados en las Centrales Termoelectricas de Ciclo Combinado (CTCC) de Dos Bocas, Veracruz y Gomez Palacio, Durango, Mexico. Tambien se describen la arquitectura, las funciones que se llevan

  13. Modeling and Control of Cogeneration Power Plants: A Hybrid System Approach

    NARCIS (Netherlands)

    G. Ferrari-Trecate (Giancarlo); E. Gallestey (Eduardo); P. Letizia (Paolo); M. Spedicato (Matteo); M. Morari (Manfred); M. Antoine (Marc)

    2004-01-01

    textabstractIn this paper the short term scheduling optimization of a combined cycle power plant is accomplished by exploiting hybrid systems, i.e. systems evolving according to continuous dynamics, discrete dynamics, and logic rules. Discrete features of a power plant are, for instance, the possibi

  14. 改造常规汽轮机电站联合循环系统的热力学分析%THERMODYNAMIC ANALYSIS OF COMBINED CYCLE-REPOWERING OF TRADITIONAL STEAM-TURBINE PLANTS

    Institute of Scientific and Technical Information of China (English)

    刘泽龙; 金红光; 蔡睿贤; 蒋洪德; 林汝谋

    2001-01-01

    联合循环系统改造(Combined Cycle-Repowering)是常规燃煤电站更新最科学最有效的方法之一。本文对两种典型的联合循环系统(排气助燃型FF-Repowering和给水加热型FWH- Repowering)进行了热力学系统模拟研究,得到了随燃机汽机功比变化排气助燃型系统效率单调变化以及给水加热型系统效率存在极值点的现象,并发现了一定燃机汽机功比下给水加热型效率大于排气助燃型的特殊规律。通过对联合循环系统改造各种因素的综合分析,揭示了上述特殊规律的热力学机理,澄清了有关研究的误区。该理论研究对采用联合循环系统技术改造常规电站具有指导意义。%Combined Cycle-Repowering is one of the most scientific andeffective way to improve the performance of existing coal based power plant.Two kinds of representative CC-Repowering (feed water heating repowering,full firing repowering) were analyzed and compared in this paper. Aremarkable phenomenon was observed: Efficiency monotonouslychanges with work-ratio in FF-Repowering system; but in FWH-Repoweringsystem, there exists an optimal ratio at which point the efficiency isthe highest. Another phenomenon to be paid attention is that under somework-ratio, the efficiency of FWH-Repowering is higher than that ofFF-Repowering, giving rise to correcting the conventional concept.After synthetic analysis of every aspect, the fundamental of thesephenomenons were revealed. Some valuable instructions for CC-Repoweringcan be drawn from this paper.

  15. Development of a ceramic heat exchanger for a combined cycle plant with pressurized coal dust combustion. Final report; Entwicklung eines keramischen Waermeaustauschers fuer eine Kombianlage mit Kohlenstaubdruckfeuerung. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Leithner, R.; Ehlers, C.

    2001-12-01

    State of Research: The Pressurized Pulverized Coal Combustion Combined Cycle (PPCCCC) with a directly fired gas turbine can reach electrical efficiencies beyond 50%. The required gas quality upstream the gas turbine has not been reached yet at temperatures above 1000 C. One approach tested is the precipitation of ash and alkalines at temperatures above the ash melting point. This principle contains problems concerning the remaining content of ash and alkalines in the flue gas and damages to the refractory materials due to corrosion. Goal of the Investigation: An alternative process had to be investigated in which the flue gas is cleaned according to the state of the art, i.e. below the ash fusion temperature. This principle requires cooling down the flue gas and heating it up again after cleaning in a high temperature heat exchanger. Method: A ceramic tube-and-shell heat exchanger in a model scale was designed and was operated at realistic conditions in an atmospheric test plant in connection with a high temperture precipitation. Result: The heat exchanger showed a good performance concerning design and material. The expected temperatures were not reached totally because of untight joints. Clogging occurred in the tube entrances at high temperatures because of sintered ash agglomerates. First tests to clean the entrances during operation showed positive results. The ash precipitation by means of a cyclone and ceramic filter candles was performed without difficulties. Conclusion: Avoiding and improving joints will help to achieve higher temperatures. A process of cleaning the tubes in-line has to be introduced to prevent the clogging effects. If this is successfully done for high temperatures, an attractive principle for a PPCCCC-process is available which reaches the gas purity required. (orig.) [German] Derzeitiger Stand der Forschung: Der Kohlenstaubdruckfeuerungs-Kombiprozess mit direkt befeuerter Gasturbine verspricht elektrische Wirkungsgrade ueber 50%. Die

  16. Advanced stellarator power plants

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.L.

    1994-07-01

    The stellarator is a class of helical/toroidal magnetic fusion devices. Recent international progress in stellarator power plant conceptual design is reviewed and comparisons in the areas of physics, engineering, and economics are made with recent tokamak design studies.

  17. Advanced stellarator power plants

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.L.

    1994-07-01

    The stellarator is a class of helical/toroidal magnetic fusion devices. Recent international progress in stellarator power plant conceptual design is reviewed and comparisons in the areas of physics, engineering, and economics are made with recent tokamak design studies.

  18. Power plant siting

    Energy Technology Data Exchange (ETDEWEB)

    Winter, J.V.; Conner, D.A.

    1978-01-01

    Just to keep up with expected demand, the US will need over 500 new power generation units by 1985. Where these power plants will be located is the subject of heated debate among utility officials, government leaders, conservationists, concerned citizens and a multitude of special interest groups. This book offers a balanced review of all of the salient factors that must be taken into consideration in selecting power plant locations. To deal with this enormously complex subject, the authors (1) offer a general overview of the history and reasoning behind present legislation on the state and national levels; (2) describe the many different agencies that have jurisdiction in power plant location, from local water authorities and city councils to state conservation boards and the Nuclear Regulatory Commission; and (3) include a state-by-state breakdown of siting laws, regulations and present licensing procedures. Architects, engineers, contractors, and others involved in plant construction and site evaluation will learn of the trade-offs that must be made in balancing the engineering, economic, and environmental impacts of plant location. The book covers such areas as availability of water supplies for generation or cooling; geology, typography, and demography of the proposed site; and even the selection of the fuel best suited for the area. Finally, the authors examine the numerous environmental aspects of power plant siting.

  19. Nuclear Power Plants (Rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Lyerly, Ray L.; Mitchell III, Walter [Southern Nuclear Engineering, Inc.

    1973-01-01

    Projected energy requirements for the future suggest that we must employ atomic energy to generate electric power or face depletion of our fossil-fuel resources—coal, oil, and gas. In short, both conservation and economic considerations will require us to use nuclear energy to generate the electricity that supports our civilization. Until we reach the time when nuclear power plants are as common as fossil-fueled or hydroelectric plants, many people will wonder how the nuclear plants work, how much they cost, where they are located, and what kinds of reactors they use. The purpose of this booklet is to answer these questions. In doing so, it will consider only central station plants, which are those that provide electric power for established utility systems.

  20. Economics and Performance Forecast of Gas Turbine Combined Cycle

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xiaotao; SUGISHITA Hideaki; NI Weidou; LI Zheng

    2005-01-01

    Forecasts of the economics and performance of gas turbine combined cycle (GTCC) with various types of gas turbines will help power plant designers to select the best type of gas turbine for future Chinese powerplants. The cost and performance of various designs were estimated using the commercial software GT PRO. Improved GTCC output will increase the system efficiency which may induce total investment and will certainly increase the cumulative cash which then will induce the cost and the payback period. The relative annual fuel output increases almost in proportion to the relative GTCC output. China should select the gas turbine that provides the most economical output according to its specific conditions. The analysis shows that a GTCC power plant with a medium-sized 100 to 200 MW output gas turbine is the most suitable for Chinese investors.

  1. Multiplex tokamak power plant

    Energy Technology Data Exchange (ETDEWEB)

    Dabiri, A.E.

    1986-07-01

    The concept of multiplexing for a fusion power core as an option for producing power is explored. Superconducting, as well as normal magnet, coils in either first or second stability regimes are considered. The results show that multiplex plants with superconducting magnets operating in the second stability regime could be competitive with the single-unit plants in some unit sizes. The key issues that impact the expected benefits of multiplexing must be investigated further. These are factory fabrication, economy of scale, the extent of equipment sharing, inherent safety, maintainability, and utility load management.

  2. Airbreathing combined cycle engine systems

    Science.gov (United States)

    Rohde, John

    1992-01-01

    The Air Force and NASA share a common interest in developing advanced propulsion systems for commercial and military aerospace vehicles which require efficient acceleration and cruise operation in the Mach 4 to 6 flight regime. The principle engine of interest is the turboramjet; however, other combined cycles such as the turboscramjet, air turborocket, supercharged ejector ramjet, ejector ramjet, and air liquefaction based propulsion are also of interest. Over the past months careful planning and program implementation have resulted in a number of development efforts that will lead to a broad technology base for those combined cycle propulsion systems. Individual development programs are underway in thermal management, controls materials, endothermic hydrocarbon fuels, air intake systems, nozzle exhaust systems, gas turbines and ramjet ramburners.

  3. Thermoeconomic Analysis of Advanced Solar-Fossil Combined Power Plants

    OpenAIRE

    Yassine Allani; Klaus Ziegler; Daniel Favrat; Malick Kane

    2000-01-01

    Hybrid solar thermal power plants (with parabolic trough type of solar collectors) featuring gas burners and Rankine steam cycles have been successfully demonstrated by California's Solar Electric Generating System (SEGS). This system has been proven to be one of the most efficient and economical schemes to convert solar energy into electricity. Recent technological progress opens interesting prospects for advanced cycle concepts: a) the ISCCS (Integrated Solar Combined Cycle System)...

  4. Nuclear Power Plant Technician

    Science.gov (United States)

    Randall, George A.

    1975-01-01

    The author recognizes a body of basic knowledge in nuclear power plant technoogy that can be taught in school programs, and lists the various courses, aiming to fill the anticipated need for nuclear-trained manpower--persons holding an associate degree in engineering technology. (Author/BP)

  5. Nuclear Power Plant Technician

    Science.gov (United States)

    Randall, George A.

    1975-01-01

    The author recognizes a body of basic knowledge in nuclear power plant technoogy that can be taught in school programs, and lists the various courses, aiming to fill the anticipated need for nuclear-trained manpower--persons holding an associate degree in engineering technology. (Author/BP)

  6. GEOTHERMAL POWER GENERATION PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196oF resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  7. Geothermal Power Generation Plant

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya [Oregon Inst. of Technology, Klamath Falls, OR (United States). Geo-Heat Center

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196°F resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  8. A solar power plant

    Energy Technology Data Exchange (ETDEWEB)

    Avakyan, Yu.V.; Dabagyan, T.N.; Gagiyan, L.A.; Kharapetyan, G.S.; Vartanyan, A.V.

    1984-01-01

    This invention is designed for solar energy collectors in the form of heat pipes. A solar power plant is proposed that contains a solar concentrator in the form of at least one heat pipe with evaporation and condensation sections, the first of which is constructed to absorb solar emission and the second located in a heat exchanger equipped with inlet and outlet pipes. In order to simplify the design, the solar power plant is equipped with an additional heat exchanger connected through a connector to the inlet and outlet pipes, while the evaporation section holds an additional section in the lower half, within the auxiliary heat exchanger. During operation as a solar energy collector, the evaporation region absorbs the solar energy and converts it to heat, which is then carried by the heat transfer medium to the heating tube.

  9. Reducing And Analysizing of Flow Accelerated Corrosion at Thermal Power Plant, Heat Recovery Steam Generators

    OpenAIRE

    Akın Avşaroğlu; Suphi URAL

    2017-01-01

    The purpose of this study is to Reducing and Analysing of Flow Accelerated Corrosion in Thermal Plant Heat Recovery Steam Generators. All these studies have been performed in a new and 16 year-old established Combined Cycle Power Plants in Turkey. Corrosion cases have been investigated due to Mechanical Outage Reports at Power Plant in 2011-2015. Flow Accelerated Corrosion study has been based on specific zone related with Economizer Low Pressure connection pipings. It was issued a performanc...

  10. Nuclear Power Plant

    Directory of Open Access Journals (Sweden)

    Analia Bonelli

    2012-01-01

    Full Text Available A description of the results for a Station Black-Out analysis for Atucha 2 Nuclear Power Plant is presented here. Calculations were performed with MELCOR 1.8.6 YV3165 Code. Atucha 2 is a pressurized heavy water reactor, cooled and moderated with heavy water, by two separate systems, presently under final construction in Argentina. The initiating event is loss of power, accompanied by the failure of four out of four diesel generators. All remaining plant safety systems are supposed to be available. It is assumed that during the Station Black-Out sequence the first pressurizer safety valve fails stuck open after 3 cycles of water release, respectively, 17 cycles in total. During the transient, the water in the fuel channels evaporates first while the moderator tank is still partially full. The moderator tank inventory acts as a temporary heat sink for the decay heat, which is evacuated through conduction and radiation heat transfer, delaying core degradation. This feature, together with the large volume of the steel filler pieces in the lower plenum and a high primary system volume to thermal power ratio, derives in a very slow transient in which RPV failure time is four to five times larger than that of other German PWRs.

  11. Determination of Fuel Consumption Indexes of Co-generation Combined Cycle Steam and Gas Units with unfired waste heat boilers

    Directory of Open Access Journals (Sweden)

    S. A. Kachan

    2010-01-01

    Full Text Available The paper presents the developed methodology and the results of determination of fuel consumption indexes of co-generation combined cycle steam and gas units (PGU with unfired waste heat boilers apply to PGU-230 of 3-d co-generation power plant ofMinsk. 

  12. Leveled cost of the generation in a power station of combined cycle with integrated gas producer (CCGI); Costo nivelado de la generacion en una central de ciclo combinado con gasificador integrado (CCGI)

    Energy Technology Data Exchange (ETDEWEB)

    Hiriart Le Bert, Gerardo [Comision Federal de Electricidad (CFE), (Mexico); Beltran Mora, Hector [Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2004-06-15

    A brief description of a combined cycle power station that uses synthesis gas, better known as CCGI, is presented. The costs of the initial investment of several plants of this type, that have been described in literature, are analyzed and the predictions that different experts do on the costs that are expected in the near future are reviewed. Also the maintenance expenses that would be expected during the normal operation and the main maintenance are examined. The availability factors that reasonably must be considered based on the recent experiences are analyzed. Afterwards the sense which that the plant factor has in one of natural gas and one of synthesis, where generally are used as base plant. The costs of the different fuels that can be used in a CCGI are examined. Finally the leveled cost of the energy for both cases is calculated and the sensitivity of both to the cost of the respective fuels is examined. The result is presented in graphical form to show in a first attempt, the circumstances under which one or another technology could be preferable. It is made clear that the data used in this brief study are the best reasoned estimation and in no way they must be considered as definitive, in special in those of investment and maintenance of the CCGI where the operation history is still short. [Spanish] Se presenta una breve descripcion de una Central de Ciclo Combinado que utiliza Gas de Sintesis o mejor conocidas como CCGI. Se analizan los costos de la inversion inicial de varias plantas de este tipo que han sido descritas en la literatura y se resenan las predicciones que hacen diferentes expertos sobre los costos que se esperan para el futuro cercano. Tambien se examinan los gastos de mantenimiento que se esperarian durante la operacion normal y durante los mantenimientos mayores. Se analizan los factores de disponibilidad que razonablemente deben considerarse, basados en las experiencias recientes. Luego se discute el sentido que tiene el factor de

  13. Current power plant

    Energy Technology Data Exchange (ETDEWEB)

    Nickell, J.H.

    1979-03-06

    A current power plant is described that includes a shaft mounted turbine wheel for employment in water current, a housing adjacent the impeller and to which the shaft extends, a ramp positioned on the upstream side of the impellar, and a frame on which the turbine wheel is mounted. The frame is mounted by rollers on a tract such that the impeller and frame may be rolled on the tracks inside the housing, whereafter doors are closed, and water around the turbine wheel may be pumped out to facilitate turbine repair.

  14. Wind power plant system services

    DEFF Research Database (Denmark)

    Basit, Abdul; Altin, Müfit

    Traditionally, conventional power plants have the task to support the power system, by supplying power balancing services. These services are required by the power system operators in order to secure a safe and reliable operation of the power system. However, as in the future the wind power...... is going more and more to replace conventional power plants, the sources of conventional reserve available to the system will be reduced and fewer conventional plants will be available on-line to share the regulation burden. The reliable operation of highly wind power integrated power system might...... then beat risk unless the wind power plants (WPPs) are able to support and participate in power balancing services. The objective of this PhD project is to develop and analyse control strategies which can increase the WPPs capability to provide system services, such as active power balancing control...

  15. Thermodynamic analysis of gas – steam combined cycle with carbon dioxide (CO2 emissions saving

    Directory of Open Access Journals (Sweden)

    Alka Gupta, Om Prakash, S.K. Shukla

    2011-03-01

    Full Text Available In this paper, cogeneration or combined heat and power (CHP cycle has been analyzed in order to improve the efficiency of the gas – steam combined cycle and utilization of waste heat. The efficiency of the combined cycle is improved by decreasing the compressor inlet temperature (CIT and increasing the turbine inlet temperature (TIT. It is observed that the cycle offers the advantage of making efficient use of the energy available in the fuel and in turn, eliminate some portion of pollution associated with the power generation. The study also reveals that if this cycle is being employed for cogeneration, there is a significant saving (11.60% in the amount of Carbon dioxide (CO2 emitted by the coal-fired thermal power plants.

  16. Study on effective parameter of the triple-pressure reheat combined cycle performance

    Directory of Open Access Journals (Sweden)

    Ibrahim Thamir K.

    2013-01-01

    Full Text Available The thermodynamic analyses of the triple-pressure reheat combined cycle gas turbines with duct burner are presented and discussed in this paper. The overall performance of a combined cycle gas turbine power plant is influenced by the ambient temperature, compression ratio and turbine inlet temperature. These parameters affect the overall thermal efficiency, power output and the heat-rate. In this study a thermodynamic model was development on an existing actual combined cycle gas turbine (CCGT (In this case study, an effort has been made to enhance the performance of the CCGT through a parametric study using a thermodynamic analysis. The effect of ambient temperature and operation parameter, including compression ratio and turbine inlet temperature, on the overall performance of CCGT are investigated. The code of the performance model for CCGT power plant was developed utilizing the THERMOFLEX software. The simulating results show that the total power output and overall efficiency of a CCGT decrease with increase the ambient temperature because increase the consumption power in the air compressor of a GT. The totals power of a CCGT decreases with increase the compression rate, while the overall efficiency of a CCGT increases with increase the compression ratio to 21, after that the overall efficiency will go down. Far there more the turbine inlet temperature increases the both total power and overall efficiency increase, so the turbine inlet temperature has a strong effect on the overall performance of CCGT power plant. Also the simulation model give a good result compared with MARAFIQ CCGT power plant. With these variables, the turbine inlet temperature causes the greatest overall performance variation.

  17. Features of erosion-corrosion wear in low-pressure evaporators of combined-cycle plant heat-recovery boilers at high void factor values

    Science.gov (United States)

    Galetsky, N. S.; Schwarz, A. L.

    2013-12-01

    The features of erosion-corrosion wear (ECW) in a low-pressure evaporator (LPE) combinedcycle plant (CCP) at high void factor values in the heat carrier are considered. It is shown that if the medium pressure in the evaporator is less than 1 MPa and steam quality x ≈ 0.5, the void fraction β is close to 1, at the outlet of the evaporator almost dry saturated steam moves, and the formation of liquid films is excluded. Under these conditions, the wear of the evaporator coil sections has an erosive nature, caused by high velocity steam, carrying the dense particles of corrosion products and large drops of water, previously plucked from the surface of the liquid films.

  18. Adaptation of thermal power plants

    NARCIS (Netherlands)

    Bogmans, Christian W.J.; Dijkema, Gerard P.J.; Vliet, van Michelle T.H.

    2017-01-01

    When does climate change information lead to adaptation? We analyze thermal power plant adaptation by means of investing in water-saving (cooling) technology to prevent a decrease in plant efficiency and load reduction. A comprehensive power plant investment model, forced with downscaled climate

  19. Adaptation of thermal power plants

    NARCIS (Netherlands)

    Bogmans, Christian W.J.; Dijkema, Gerard P.J.; Vliet, van Michelle T.H.

    2017-01-01

    When does climate change information lead to adaptation? We analyze thermal power plant adaptation by means of investing in water-saving (cooling) technology to prevent a decrease in plant efficiency and load reduction. A comprehensive power plant investment model, forced with downscaled climate

  20. Thermoeconomic Analysis of Advanced Solar-Fossil Combined Power Plants

    Directory of Open Access Journals (Sweden)

    Yassine Allani

    2000-12-01

    Full Text Available

    Hybrid solar thermal power plants (with parabolic trough type of solar collectors featuring gas burners and Rankine steam cycles have been successfully demonstrated by California's Solar Electric Generating System (SEGS. This system has been proven to be one of the most efficient and economical schemes to convert solar energy into electricity. Recent technological progress opens interesting prospects for advanced cycle concepts: a the ISCCS (Integrated Solar Combined Cycle System that integrates the parabolic trough into a fossil fired combined cycle, which allows a larger exergy potential of the fuel to be converted. b the HSTS (Hybrid Solar Tower System which uses high concentration optics (via a power tower generator and high temperature air receivers to drive the combined cycle power plant. In the latter case, solar energy is used at a higher exergy level as a heat source of the topping cycle. This paper presents the results of a thermoeconomic investigation of an ISCCS envisaged in Tunisia. The study is realized in two phases. In the first phase, a mixed approach, based on pinch technology principles coupled with a mathematical optimization algorithm, is used to minimize the heat transfer exergy losses in the steam generators, respecting the off design operating conditions of the steam turbine (cone law. In the second phase, an economic analysis based on the Levelized Electricity Cost (LEC approach was carried out for the configurations, which provided the best concepts during the first phase. A comparison of ISCCS with pure fossil fueled plants (CC+GT is reported for the same electrical power load. A sensitivity analysis based on the relative size of the solar field is presented.

    •  This paper was presented at the ECOS'00 Conference in Enschede, July 5-7, 2000

  1. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self‐funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty‐three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  2. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University's aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  3. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  4. Prospects for advanced coal-fuelled fuel cell power plants

    Science.gov (United States)

    Jansen, D.; Vanderlaag, P. C.; Oudhuis, A. B. J.; Ribberink, J. S.

    1994-04-01

    As part of ECN's in-house R&D programs on clean energy conversion systems with high efficiencies and low emissions, system assessment studies have been carried out on coal gasification power plants integrated with high-temperature fuel cells (IGFC). The studies also included the potential to reduce CO2 emissions, and to find possible ways for CO2 extraction and sequestration. The development of this new type of clean coal technology for large-scale power generation is still far off. A significant market share is not envisaged before the year 2015. To assess the future market potential of coal-fueled fuel cell power plants, the promise of this fuel cell technology was assessed against the performance and the development of current state-of-the-art large-scale power generation systems, namely the pulverized coal-fired power plants and the integrated coal gasification combined cycle (IGCC) power plants. With the anticipated progress in gas turbine and gas clean-up technology, coal-fueled fuel cell power plants will have to face severe competition from advanced IGCC power plants, despite their higher efficiency.

  5. Analysis of energetic and exergetic efficiency, and environmental benefits of biomass integrated gasification combined cycle technology.

    Science.gov (United States)

    Mínguez, María; Jiménez, Angel; Rodríguez, Javier; González, Celina; López, Ignacio; Nieto, Rafael

    2013-04-01

    The problem of the high carbon dioxide emissions linked to power generation makes necessary active research on the use of biofuels in gas turbine systems as a promising alternative to fossil fuels. Gasification of biomass waste is particularly of interest in obtaining a fuel to be run in gas turbines, as it is an efficient biomass-to-biofuel conversion process, and an integration into a combined cycle power plant leads to a high performance with regard to energetic efficiency. The goal of this study was to carry out an energetic, exergetic and environmental analysis of the behaviour of an integrated gasification combined cycle (IGCC) plant fuelled with different kinds of biomass waste by means of simulations. A preliminary economic study is also included. Although a technological development in gasification technology is necessary, the results of simulations indicate a high technical and environmental interest in the use of biomass integrated gasification combined cycle (BioIGCC) systems for large-scale power generation from biomass waste.

  6. Pre-Combustion Carbondioxide Capture in Integrated Gasification Combined Cycles

    Directory of Open Access Journals (Sweden)

    M. Zeki YILMAZOĞLU

    2010-02-01

    Full Text Available Thermal power plants have a significant place big proportion in the production of electric energy. Thermal power plants are the systems which converts heat energy to mechanical energy and also mechanical energy to electrical energy. Heat energy is obtained from combustion process and as a result of this, some harmful emissions, like CO2, which are the reason for global warming, are released to atmosphere. The contribution of carbondioxide to global warming has been exposed by the previous researchs. Due to this fact, clean energy technologies are growing rapidly all around the world. Coal is generally used in power plants and when compared to other fossil energy sources unit electricity production cost is less than others. When reserve rate is taken into account, coal may be converted to energy in a more efficient and cleaner way. The aim for using the clean coal technologies are to eradicate the harmful emissions of coal and to store the carbondioxide, orginated from combustion, in different forms. In line with this aim, carbondioxide may be captured by either pre-combustion, by O2/CO2 recycling combustion systems or by post combustion. The integrated gasification combined cycles (IGCC are available in pre-combustion capture systems, whereas in O2/CO2 recycling combustion systems there are ultrasuper critical boiler technologies and finally flue gas washing systems by amines exists in post combustion systems. In this study, a pre-combustion CO2 capture process via oxygen blown gasifiers is compared with a conventional power plant in terms of CO2 emissions. Captured carbondioxide quantity has been presented as a result of the calculations made throughout the study.

  7. Direct FuelCell/Turbine Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Hossein Ghezel-Ayagh

    2008-09-30

    This report summarizes the progress made in development of Direct FuelCell/Turbine (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T system employs an indirectly heated Turbine Generator to supplement fuel cell generated power. The concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, minimal emissions, reduced carbon dioxide release to the environment, simplicity in design, direct reforming internal to the fuel cell, and potential cost competitiveness with existing combined cycle power plants. Proof-of-concept tests using a sub-MW-class DFC/T power plant at FuelCell Energy's (FCE) Danbury facility were conducted to validate the feasibility of the concept and to measure its potential for electric power production. A 400 kW-class power plant test facility was designed and retrofitted to conduct the tests. The initial series of tests involved integration of a full-size (250 kW) Direct FuelCell stack with a 30 kW Capstone microturbine. The operational aspects of the hybrid system in relation to the integration of the microturbine with the fuel cell, process flow and thermal balances, and control strategies for power cycling of the system, were investigated. A subsequent series of tests included operation of the sub-MW Direct FuelCell/Turbine power plant with a Capstone C60 microturbine. The C60 microturbine extended the range of operation of the hybrid power plant to higher current densities (higher power) than achieved in initial tests using the 30kW microturbine. The proof-of-concept test results confirmed the stability and controllability of operating a fullsize (250 kW) fuel cell stack in combination with a microturbine. Thermal management of the system was confirmed and power plant operation, using the microturbine as the only source of fresh air supply

  8. Identification of hazards in non-nuclear power plants. Volume II. Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Fell, R.W.

    1979-08-01

    This study extends the Phase I study to also include a hazards evaluation for two new emerging coal power plant technologies: coal fired atmospheric fluidized bed and pressurized fluidized bed power generating systems. The study also considers the sensitivity of the hazards ranking for all the non-nuclear power plants to the effects of population density, mode of plant operation, technical changes, location and environmental (temperature) effects. Information is provided under the following section headings: background; environmental and public health concerns associated with fluidized-bed combustion power plants; description of a conceptual atmospheric fluidized-bed power plant; pressurized fluidized-bed combustion combined cycle (PFBCC) power plant; hazard ranking and risk assessment for non-nuclear power plants; and, hazards sensitivity analysis.

  9. INTEGRATED GASIFICATION COMBINED CYCLE PROJECT 2 MW FUEL CELL DEMONSTRATION

    Energy Technology Data Exchange (ETDEWEB)

    FuelCell Energy

    2005-05-16

    With about 50% of power generation in the United States derived from coal and projections indicating that coal will continue to be the primary fuel for power generation in the next two decades, the Department of Energy (DOE) Clean Coal Technology Demonstration Program (CCTDP) has been conducted since 1985 to develop innovative, environmentally friendly processes for the world energy market place. The 2 MW Fuel Cell Demonstration was part of the Kentucky Pioneer Energy (KPE) Integrated Gasification Combined Cycle (IGCC) project selected by DOE under Round Five of the Clean Coal Technology Demonstration Program. The participant in the CCTDP V Project was Kentucky Pioneer Energy for the IGCC plant. FuelCell Energy, Inc. (FCE), under subcontract to KPE, was responsible for the design, construction and operation of the 2 MW fuel cell power plant. Duke Fluor Daniel provided engineering design and procurement support for the balance-of-plant skids. Colt Engineering Corporation provided engineering design, fabrication and procurement of the syngas processing skids. Jacobs Applied Technology provided the fabrication of the fuel cell module vessels. Wabash River Energy Ltd (WREL) provided the test site. The 2 MW fuel cell power plant utilizes FuelCell Energy's Direct Fuel Cell (DFC) technology, which is based on the internally reforming carbonate fuel cell. This plant is capable of operating on coal-derived syngas as well as natural gas. Prior testing (1992) of a subscale 20 kW carbonate fuel cell stack at the Louisiana Gasification Technology Inc. (LGTI) site using the Dow/Destec gasification plant indicated that operation on coal derived gas provided normal performance and stable operation. Duke Fluor Daniel and FuelCell Energy developed a commercial plant design for the 2 MW fuel cell. The plant was designed to be modular, factory assembled and truck shippable to the site. Five balance-of-plant skids incorporating fuel processing, anode gas oxidation, heat recovery

  10. An insight on reheat gas turbine for combined cycles

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Marco A.C.; Carneiro, Helder F.F.M.; Barbosa, Joao R. [Centro Tecnico Aeroespacial, Sao Jose dos Campos, SP (Brazil). Inst. Tecnologico de Aeronautica. Dept. de Energia]. E-mail: marco@asap.iae.cta.br; helder@asap.iae.cta.br; barbosa@mec.ita.cta.br; Travieso, Luis E. [Universidad de la Republica, Montevideo (Uruguay)]. E-mail: travisan@adinet.com.uy; Pilidis, Pericles [Cranfield University, Beds (United Kingdom)]. E-mail: p.pilidis@cranfield.ac.uk

    2000-07-01

    The design point performance of reheat gas turbines for combined cycle is investigated in this work. A comparison of reheat and simple cycle results is used to draw the main conclusions. Some conclusions available in the literature were confirmed; such as the fact that reheat increases the specific power and reduces the efficiency of the gas turbines. The latter is mainly a consequence of the increase of the amount of energy (heat) lost in the exhaust, represented by an increase in turbine exhaust temperature. Thus, the reheat cycle gas turbine can be considered well suitable to combined cycle. In this case the reheat combined cycle efficiency increases, compared to simple cycle, in spite of the reduction in efficiency of the gas turbine reheat cycle, with the advantage of a significant increase in specific power. (author)

  11. Integrated gasification combined cycle (IGCC) process simulation and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Emun, F.; Gadalla, M.; Majozi, T.; Boer, D. [University of Rovira & Virgili, Tarragona (Spain). Dept. of Chemical Engineering

    2010-03-05

    The integrated gasification combined cycle (IGCC) is an electrical power generation system which offers efficient generation from coal with lower effect on the environment than conventional coal power plants. However, further improvement of its efficiency and thereby lowering emissions are important tasks to achieve a more sustainable energy production. In this paper, a process simulation tool is proposed for simulation of IGCC. This tool is used to improve IGCC's efficiency and the environmental performance through an analysis of the operating conditions, together with process integration studies. Pinch analysis principles and process integration insights are then employed to make topological changes to the flowsheet to improve the energy efficiency and minimize the operation costs. Process data of the Texaco gasifier and the associated plants (coal preparation, air separation unit, gas cleaning, sulfur recovery, gas turbine, steam turbine and the heat recovery steam generator) are considered as a base case, and simulated using Aspen Plus. The results of parameter analysis and heat integration studies indicate that thermal efficiency of 45% can be reached, while a significant decrease in CO{sub 2} and SOx emissions is observed. The CO{sub 2} and SOx emission levels reached are 698 kg/MWh and 0.15 kg/MWh, respectively. Application of pinch analysis determines energy targets, and also identifies potential modifications for further improvement to overall energy efficiency. Benefits of energy integration and steam production possibilities can further be quantified. Overall benefits can be translated to minimum operation costs and atmospheric emissions.

  12. AND THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Alduhov Oleg Aleksandrovich

    2012-10-01

    Full Text Available Investigation of the atmospheric dispersion as part of the process of selection of sites to accommodate nuclear and thermal power plants is performed to identify concentration fields of emissions and to assess the anthropogenic impact produced on the landscape components and human beings. Scattering properties of the atmospheric boundary layer are mainly determined by the turbulence intensity and the wind field. In its turn, the turbulence intensity is associated with the thermal stratification of the boundary layer. Therefore, research of the atmospheric dispersion is reduced to the study of temperature and wind patterns of the boundary layer. Statistical processing and analysis of the upper-air data involves the input of the data collected by upper-air stations. Until recently, the upper-air data covering the standard period between 1961 and 1970 were applied for these purposes, although these data cannot assure sufficient reliability of assessments in terms of the properties of the atmospheric dispersion. However, recent scientific and technological developments make it possible to substantially increase the data coverage by adding the upper-air data collected within the period between 1964 and 2010. The article has a brief overview of BL_PROGS, a specialized software package designated for the processing of the above data. The software package analyzes the principal properties of the atmospheric dispersion. The use of the proposed software package requires preliminary development of a database that has the information collected by an upper-air station. The software package is noteworthy for the absence of any substantial limitations imposed onto the amount of the input data that may go up in proportion to the amount of the upper-air data collected by upper-air stations.

  13. Simulating solar power plant variability :

    Energy Technology Data Exchange (ETDEWEB)

    Lave, Matthew Samuel; Ellis, Abraham; Stein, Joshua.

    2013-06-01

    It is important to be able to accurately simulate the variability of solar PV power plants for grid integration studies. We aim to inform integration studies of the ease of implementation and application-specific accuracy of current PV power plant output simulation methods. This report reviews methods for producing simulated high-resolution (sub-hour or even sub-minute) PV power plant output profiles for variability studies and describes their implementation. Two steps are involved in the simulations: estimation of average irradiance over the footprint of a PV plant and conversion of average irradiance to plant power output. Six models are described for simulating plant-average irradiance based on inputs of ground-measured irradiance, satellite-derived irradiance, or proxy plant measurements. The steps for converting plant-average irradiance to plant power output are detailed to understand the contributions to plant variability. A forthcoming report will quantify the accuracy of each method using application-specific validation metrics.

  14. Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 5: Combined gas-steam turbine cycles. [energy conversion efficiency in electric power plants

    Science.gov (United States)

    Amos, D. J.; Foster-Pegg, R. W.; Lee, R. M.

    1976-01-01

    The energy conversion efficiency of gas-steam turbine cycles was investigated for selected combined cycle power plants. Results indicate that it is possible for combined cycle gas-steam turbine power plants to have efficiencies several point higher than conventional steam plants. Induction of low pressure steam into the steam turbine is shown to improve the plant efficiency. Post firing of the boiler of a high temperature combined cycle plant is found to increase net power but to worsen efficiency. A gas turbine pressure ratio of 12 to 1 was found to be close to optimum at all gas turbine inlet temperatures that were studied. The coal using combined cycle plant with an integrated low-Btu gasifier was calculated to have a plant efficiency of 43.6%, a capitalization of $497/kW, and a cost of electricity of 6.75 mills/MJ (24.3 mills/kwh). This combined cycle plant should be considered for base load power generation.

  15. Reducing And Analysizing of Flow Accelerated Corrosion at Thermal Power Plant, Heat Recovery Steam Generators

    Directory of Open Access Journals (Sweden)

    Akın Avşaroğlu

    2017-01-01

    Full Text Available The purpose of this study is to Reducing and Analysing of Flow Accelerated Corrosion in Thermal Plant Heat Recovery Steam Generators. All these studies have been performed in a new and 16 year-old established Combined Cycle Power Plants in Turkey. Corrosion cases have been investigated due to Mechanical Outage Reports at Power Plant in 2011-2015. Flow Accelerated Corrosion study has been based on specific zone related with Economizer Low Pressure connection pipings. It was issued a performance report. Results and lessons learnt from these studies will be used as a preventive action manner in all similar Plants.

  16. Asbury power plant, Asbury, Missouri

    Energy Technology Data Exchange (ETDEWEB)

    Wicker, K.

    2005-08-01

    The Asbury power plant in rural southwest Missouri is off the beaten path in more ways than one. Three years ago, Empire District Electric Co., the plant's owner/operator, began mixing pieces of discarded tires into its coal fuel supply. Each ensuing year, without compromising local air quality, the plant has rid the area of millions of tires that otherwise would have ended up in a landfill. For demonstrating that a blight can be made right, Asbury is one of Power's 2005 top plants. 2 figs., 1 tab.

  17. Direct FuelCell/Turbine Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Hossein Ghezel-Ayagh

    2008-09-30

    This report summarizes the progress made in development of Direct FuelCell/Turbine (DFC/T{reg_sign}) power plants for generation of clean power at very high efficiencies. The DFC/T system employs an indirectly heated Turbine Generator to supplement fuel cell generated power. The concept extends the high efficiency of the fuel cell by utilizing the fuel cell's byproduct heat in a Brayton cycle. Features of the DFC/T system include: electrical efficiencies of up to 75% on natural gas, minimal emissions, reduced carbon dioxide release to the environment, simplicity in design, direct reforming internal to the fuel cell, and potential cost competitiveness with existing combined cycle power plants. Proof-of-concept tests using a sub-MW-class DFC/T power plant at FuelCell Energy's (FCE) Danbury facility were conducted to validate the feasibility of the concept and to measure its potential for electric power production. A 400 kW-class power plant test facility was designed and retrofitted to conduct the tests. The initial series of tests involved integration of a full-size (250 kW) Direct FuelCell stack with a 30 kW Capstone microturbine. The operational aspects of the hybrid system in relation to the integration of the microturbine with the fuel cell, process flow and thermal balances, and control strategies for power cycling of the system, were investigated. A subsequent series of tests included operation of the sub-MW Direct FuelCell/Turbine power plant with a Capstone C60 microturbine. The C60 microturbine extended the range of operation of the hybrid power plant to higher current densities (higher power) than achieved in initial tests using the 30kW microturbine. The proof-of-concept test results confirmed the stability and controllability of operating a fullsize (250 kW) fuel cell stack in combination with a microturbine. Thermal management of the system was confirmed and power plant operation, using the microturbine as the only source of fresh air supply

  18. Topping gas turbines improve steam power plant efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Lezuo, A. (Siemens AG, Erlangen (Germany, F.R.). KWU Group)

    An interesting option for improving the efficiency and output of an existing conventional steam power plant is to convert it into a combined steam-and-gas cycle power plant by adding a topping gas turbine. The investment involved is relatively low, the payback period is short, and the low specific fuel consumption makes it possible to save on overall running costs. At the same time, the amount of residue for disposal and also pollutant emissions are drastically reduced. This article describes the configuration of a fully-fired combined-cycle power plant and discusses thermodynamic design and efficiency, operational aspects, emissions and residues and investment and economic viability. Both coal-fired and gas or oil-fired steam power plants can be converted by adding a topping cycle and the investment cost is about 20% of the cost of a new plant with the same output rating as the plant to be converted. Conversion reduces pollutant emission and residues produced (SO{sub 2}, NO{sub x}, CO{sub 2}, dust, ash, gypsum, waste heat). 4 figs.

  19. Nuclear Power Plant Simulation Game.

    Science.gov (United States)

    Weiss, Fran

    1979-01-01

    Presents a nuclear power plant simulation game which is designed to involve a class of 30 junior or senior high school students. Scientific, ecological, and social issues covered in the game are also presented. (HM)

  20. Power Plant Water Intake Assessment.

    Science.gov (United States)

    Zeitoun, Ibrahim H.; And Others

    1980-01-01

    In order to adequately assess the impact of power plant cooling water intake on an aquatic ecosystem, total ecosystem effects must be considered, rather than merely numbers of impinged or entrained organisms. (Author/RE)

  1. General conditions for gas-fired power plants in Europe; Rahmenbedingungen fuer Gaskraftwerke in Europa

    Energy Technology Data Exchange (ETDEWEB)

    Hugi, Ch.; Fuessler, J.; Sommerhalder, M.

    2006-11-15

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) takes a look at the general conditions for the installation of gas-fired power plants in Europe. Combined cycle power stations are characterised and the associated power production costs are discussed. Also, the prices resulting from the internalisation of external costs are noted. The problems associated with carbon dioxide emissions are discussed and the trading of emission certificates is looked at. Also, nitrogen oxide emissions are examined and discussed. The use of waste heat from the combined cycle power stations is also examined. Further topics include subsidies and special credits for the gas industry in Europe and the granting of permission for the planning, construction, operation and dismantling of the power station facilities. The situation in various European countries is examined and the associated market distortion is commented on

  2. Robust velocity and load control of a steam turbine in a combined cycle thermoelectric power station; Control robusto de velocidad y carga de una turbina de vapor en una central termoelectrica de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Archundia, Enrique

    1998-12-31

    This research work is oriented to design, develop and validate an algorithm of modern control, that allows obtaining better performances in the control of speed of a steam turbine pertaining to a combined cycle thermoelectric power station, in all the operation interval, as well as obtaining better performances in the control of the amount of generated megawatts by the same when it is connected to an electric power generator, comparing the performance with the one obtained by means of the existing conventional controller. The changes in the speed reference or load are at the request of the operator and they always occur in incline form, indicating the rapidity with which it is desired to carry out the change of value in the reference. This is the reason for why the main objective of the control to design is to make a good follow up to references of the incline type. In the subsystem of the existing steam turbine the disadvantage is that the valves that regulate the steam flow to the turbine present a connection with the bypass valve that allows to derive the steam flow towards the main condenser without going through the turbine. It is for this reason that a multi-variable control that contemplates the interaction that occurs among the valves just mentioned, departing from a single variable design. The robust control H{infinity} has the following characteristics that allow it to be applied to the steam turbine process: the design can be made to have two poles in the origin, with which a good follow up to references of incline type is obtained; it allows the uncertainty handling, with which good results in everything are expected an entire operation interval; and it allows the design of multi-variable controllers, with which the existing interaction between the valves of control and bypass is considered. It is very difficult to be able to make tests with the real process, due to the cost and risks that it implies, nevertheless, the developments achieved in the areas

  3. 76 FR 77963 - Oglethorpe Power Corporation; Proposed Biomass Power Plant

    Science.gov (United States)

    2011-12-15

    ...; ] DEPARTMENT OF AGRICULTURE Rural Utilities Service Oglethorpe Power Corporation; Proposed Biomass Power Plant... (Oglethorpe) for the construction of a 100 megawatt (MW) biomass plant and related facilities (Proposal)...

  4. PV power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the international seminar of the Ostbayerisches Technologie-Transfer-Institut e.V. (OTTI) at 11th June, 2012 in Munich (Federal Republic of Germany), the following lectures were held: (1) Technical due diligence (Dietmar Obst); (2) Certification / rating system for large PV plants (Robert Pfatischer); (3) O and M requirements (Lars Rulf); (4) IR photography for large scale systems (Bernhard Weinreich); (5) New market models for PV systems - direct marketing and sales of PV electricity (Martin Schneider); (6) Needs and benefits for plant certification for grid connection and operation (Christoph Luetke-Lengerich); (7) Lare volume module testing / Screening in the field and workshop (Semir Merzoug); (8) Dismantling costs of large scale PV plants (Siegfried Schimpf).

  5. Operate a Nuclear Power Plant.

    Science.gov (United States)

    Frimpter, Bonnie J.; And Others

    1983-01-01

    Describes classroom use of a computer program originally published in Creative Computing magazine. "The Nuclear Power Plant" (runs on Apple II with 48K memory) simulates the operating of a nuclear generating station, requiring students to make decisions as they assume the task of managing the plant. (JN)

  6. Health-safety and environmental risk assessment of power plants using multi criteria decision making method

    Directory of Open Access Journals (Sweden)

    Jozi Ali Seyed

    2011-01-01

    Full Text Available Growing importance of environmental issues at global and regional levels including pollution of water, air etc. as well as the outcomes such as global warming and climate change has led to being considered environmental aspects as effective factors for power generation. Study ahead, aims at examination of risks resulting from activities of Yazd Combined Cycle Power Plant located in Iran. Method applied in the research is analytical hierarchy process. After identification of factors causing risk, the analytical hierarchy structure of the power plant risks were designed and weight of the criteria and sub-criteria were calculated by intensity probability product using Eigenvector Method and EXPERT CHOICE Software as well. Results indicate that in technological, health-safety, biophysical and socio economic sections of the power plant, factors influenced by the power plant activities like fire and explosion, hearing loss, quantity of groundwater, power generation are among the most important factors causing risk in the power plant. The drop in underground water levels is the most important natural consequence influenced on Yazd Combined Cycle Power Plant.

  7. Integrated solar combined cycles using gas turbines with partial recuperation and solar integration at different pressure levels

    Science.gov (United States)

    Rovira, Antonio; Sánchez, Consuelo; Fernández, Santiago; Muñoz, Marta; Barbero, Rubén

    2017-06-01

    This work studies and compares two alternatives to improve the solar-to-electricity energy conversion efficiency in integrated solar combined cycle power plants (ISCC), which are based on the use of combined cycles including partial recuperative gas turbines. Each alternative has been integrated into dual and triple pressure levels with reheat heat recovery steam generators (HRSG). Partial recuperation conveys lower heat recovery at the steam generator than in conventional plants, because each MW exchanged in the recuperator is not available at the HRSG. This thermal power decrease at the HRSG may be overcome by the integration of solar energy that is implemented using parabolic trough collectors. Moreover, with such an implementation each solar thermal MW integrated allows a MW of heat recuperation and, thus a MW of fossil fuel saving, thus the solar heat-to-electricity energy conversion rate may reach values up to 50 %, which makes the proposal interesting.

  8. International water and steam quality standards on thermal power plants at all-volatile treatment

    Science.gov (United States)

    Petrova, T. I.; Orlov, K. A.; Dooley, R. B.

    2016-12-01

    One of the methods for the improvement of reliability and efficiency of the equipment at heat power plants is the decrease in the rate of corrosion of structural materials and sedimentation in water/steam circuit. These processes can be reduced to minimum by using the water with low impurity content and coolant treatment. For many years, water and steam quality standards were developed in various countries (United States, Germany, Japan, etc.) for specific types of equipment. The International Association for the Properties of Water and Steam (IAPWS), which brings together specialists from 21 countries, developed the water and steam quality standards for various types of power equipment based on theoretical studies and long-term operating experience of power equipment. Recently, various water-chemistry conditions are applied on heatpower equipment including conventional boilers and HRSGs with combined cycle power plants (Combined Cycle Power Plants (CCPP)). In paper, the maintenance conditions of water chemistry with ammonia or volatile amine dosing are described: reducing AVT(R), oxidizing AVT(O), and oxygen OT. Each of them is provided by the water and steam quality standards and recommendations are given on their maintenance under various operation conditions. It is noted that the quality control of heat carrier must be carried out with a particular care on the HPPs with combined cycle gas turbine units, where frequent starts and halts are performed.

  9. Hybrid power plants; Thermische Hybridkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Tuschy, I. [ALSTOM Power Support, Mannheim (Germany). Bereiche Forschung und Entwicklung/Ingenieurdienstleistungen; Franke, U. [Fachhochschule Flensburg (Germany). Thermodynamik

    2002-07-01

    New German laws concerning the use of biomass and other renewable energy sources have improved the conditions for power generation with renewable energies. A promising alternative to common small-scale (combined-heat-and-) power plants could be found in so-called hybrid power plants which use renewable energies and fossil fuels in combination. A thermodynamic process analysis shows how to determine the renewable energies' portion of a hybrid power plant's total output. [German] Mit den veraenderten gesetzlichen Rahmenbedingungen erhoeht sich die Motivation, regenerative Energiequellen zur Stromerzeugung zu nutzen. Neben dem exklusiven Einsatz in kleineren (Heiz-) Kraftwerken bietet sich die gemeinsame Nutzung mit fossilen Energietraegern in sogenannten Hybridkraftwerken an. Hier stellt sich die Frage, wie der Anteil der regenerativen Energien an der Gesamt-Stromproduktion des Hybridkraftwerkes zu ermitteln ist. Eine thermodynamische Prozessanalyse kann darueber Aufschluss geben.

  10. Physico-chemical characterization of slag waste coming from GICC thermal power plant

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, A.; Aineto, M.; Iglesias, I. [Laboratory of Applied Mineralogy, Universidad de Castilla-La Mancha, Ciudad Real Madrid (Spain); Romero, M.; Rincon, J.Ma. [The Glass-Ceramics Laboratory, Insituto Eduardo Torroja de Ciencias de la Construccion, CSIC, c/Serrano Galvache s/n, 28033, Madrid (Spain)

    2001-09-01

    The new gas installations of combined cycle (GICC) thermal power plants for production of electricity are more efficient than conventional thermal power plants, but they produce a high quantity of wastes in the form of slags and fly ashes. Nowadays, these by-products are stored within the production plants with, until now, no applications of recycling in other industrial processes. In order to evaluate the capability of these products for recycling in glass and ceramics inductory, an investigation for the full characterization has been made by usual physico-chemical methods such as: chemical analysis, mineralogical analysis by XRD, granulometry, BET, DTA/TG, heating microscopy and SEM/EDX.

  11. ALARA at nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Baum, J.W.

    1990-01-01

    Implementation of the As Low As Reasonably Achievable (ALARA) principle at nuclear power plants presents a continuing challenge for health physicists at utility corporate and plant levels, for plant designers, and for regulatory agencies. The relatively large collective doses at some plants are being addressed though a variety of dose reduction techniques. It is planned that this report will include material on historical aspects, management, valuation of dose reduction, quantitative and qualitative aspects of optimization, design, operational considerations, and training. The status of this work is summarized in this report. 30 refs., 1 fig., 6 tabs.

  12. MHD-steam thermal power plant electrical stations with zero stack emission

    Energy Technology Data Exchange (ETDEWEB)

    Borghi, C.A.; Botti, M.; Ribani, P.L. [Univ. of Bologna (Italy)

    1994-12-31

    In the present work a system study of a combined cycle MHD-steam thermal power plant electrical station with zero stack emission through recirculation of CO{sub 2}, is presented. The design of the MHD generator of the topper is done by means of a quasi-one-dimensional optimisation model. The thermodynamic of the combustion gas, typical of this cycle, is considered. The technology of the components is conventional. An overall efficiency larger than 41% for power plants with electrical power inputs above 600 MWe, are obtained.

  13. Performance Comparison on Repowering of a Steam Power Plant with Gas Turbines and Solid Oxide Fuel Cells

    OpenAIRE

    Masoud Rokni

    2016-01-01

    Repowering is a process for transforming an old power plant for greater capacity and/or higher efficiency. As a consequence, the repowered plant is characterized by higher power output and less specific CO2 emissions. Usually, repowering is performed by adding one or more gas turbines into an existing steam cycle which was built decades ago. Thus, traditional repowering results in combined cycles (CC). High temperature fuel cells (such as solid oxide fuel cell (SOFC)) could also be used as a ...

  14. Thermal Power Plant Performance Analysis

    CERN Document Server

    2012-01-01

    The analysis of the reliability and availability of power plants is frequently based on simple indexes that do not take into account the criticality of some failures used for availability analysis. This criticality should be evaluated based on concepts of reliability which consider the effect of a component failure on the performance of the entire plant. System reliability analysis tools provide a root-cause analysis leading to the improvement of the plant maintenance plan.   Taking in view that the power plant performance can be evaluated not only based on  thermodynamic related indexes, such as heat-rate, Thermal Power Plant Performance Analysis focuses on the presentation of reliability-based tools used to define performance of complex systems and introduces the basic concepts of reliability, maintainability and risk analysis aiming at their application as tools for power plant performance improvement, including: ·         selection of critical equipment and components, ·         defini...

  15. Exergoeconomic evaluation of a KRW-based IGCC power plant

    Science.gov (United States)

    Tsatsaronis, G.; Lin, L.; Tawfik, T.; Gallaspy, D. T.

    1994-04-01

    In a study supported by the U.S. Department of Energy, several design configurations of Kellogg-Rust-Westinghouse (KRW)-based Integrated Gasification-Combined-Cycle (IGCC) power plants were developed. One of these configurations was analyzed from the exergoeconomic (thermoeconomic) viewpoint. This design configuration uses an air-blown KRW gasifier, hot gas cleanup, and two General Electric MS7001F advanced combustion turbines. Operation at three different gasification temperatures was considered. The detailed exergoeconomic evaluation identified several changes for improving the cost effectiveness of this IGCC design configuration. These changes include the following: decreasing the gasifier operating temperature, enhancing the high-pressure steam generation in the gasification island, improving the efficiency of the steam cycle, and redesigning the entire heat exchanger network. Based on the cost information supplied by the M. W. Kellogg Company, an attempt was made to calculate the economically optimal exergetic efficiency for some of the most important plant components.

  16. Reliability Characteristics of Power Plants

    Directory of Open Access Journals (Sweden)

    Zbynek Martinek

    2017-01-01

    Full Text Available This paper describes the phenomenon of reliability of power plants. It gives an explanation of the terms connected with this topic as their proper understanding is important for understanding the relations and equations which model the possible real situations. The reliability phenomenon is analysed using both the exponential distribution and the Weibull distribution. The results of our analysis are specific equations giving information about the characteristics of the power plants, the mean time of operations and the probability of failure-free operation. Equations solved for the Weibull distribution respect the failures as well as the actual operating hours. Thanks to our results, we are able to create a model of dynamic reliability for prediction of future states. It can be useful for improving the current situation of the unit as well as for creating the optimal plan of maintenance and thus have an impact on the overall economics of the operation of these power plants.

  17. State power plant productivity programs

    Energy Technology Data Exchange (ETDEWEB)

    1981-02-01

    The findings of a working group formed to review the status of efforts by utilities and utility regulators to increase the availability and reliability of generating units are presented. Representatives from nine state regulatory agencies, NRRI, and DOE, participated on the Working Group. The Federal government has been working cooperatively with utilities, utility organizations, and with regulators to encourage and facilitate improvements in power plant productivity. Cooperative projects undertaken with regulatory and energy commissions in California, Illinois, New York, Ohio, Texas, North Carolina and Mighigan are described. Following initiation of these cooperative projects, DOE funded a survey to determine which states were explicitly addressing power plant productivity through the regulatory process. The Working Group was formed following completion of this survey. The Working Group emphasized the need for those power plant productivity improvements which are cost effective. The cost effectiveness of proposed availability improvement projects should be determined within the context of opportunities for operating and capital improvements available to an entire utility. The Working Group also identified the need for: allowing for plant designs that have a higher construction cost, but are also more reliable; allowing for recovery and reducing recovery lags for productivity-related capital expenditures; identifying and reducing disincentives in the regulatory process; ascertaining that utilities have sufficient money available to undertake timely maintenance; and support of EPRI and NERC to develop a relevant and accurate national data base. The DOE views these as extremely important aspects of any regulatory program to improve power plant productivity.

  18. NOVEL GAS CLEANING/CONDITIONING FOR INTEGRATED GASIFICATION COMBINED CYCLE

    Energy Technology Data Exchange (ETDEWEB)

    Javad Abbasian

    2001-07-01

    The objective of this program is to develop and evaluate novel sorbents for the Siemens Westinghouse Power Company's (SWPC's) ''Ultra-Clean Gas Cleaning Process'' for reducing to near-zero levels the sulfur- and chlorine-containing gas emissions and fine particulate matter (PM2.5) caused by fuel bound constituents found in carbonaceous materials, which are processed in Integrated Gasification Combined Cycle (IGCC) technologies.

  19. Wabash River Coal Gasification Combined Cycle Repowering Project: Clean Coal Technology Program. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The proposed project would result in a combined-cycle power plant with lower emissions and higher efficiency than most existing coal-fired power plants of comparable size. The net plant heat rate (energy content of the fuel input per useable electrical generation output; i.e., Btu/kilowatt hour) for the new repowered unit would be a 21% improvement over the existing unit, while reducing SO{sub 2} emissions by greater than 90% and limiting NO{sub x} emissions by greater than 85% over that produced by conventional coal-fired boilers. The technology, which relies on gasified coal, is capable of producing as much as 25% more electricity from a given amount of coal than today`s conventional coal-burning methods. Besides having the positive environmental benefit of producing less pollutants per unit of power generated, the higher overall efficiency of the proposed CGCC project encourages greater utilization to meet base load requirements in order to realize the associated economic benefits. This greater utilization (i.e., increased capacity factor) of a cleaner operating plant has global environmental benefits in that it is likely that such power would replace power currently being produced by less efficient plants emitting a greater volume of pollutants per unit of power generated.

  20. EFFICIENCY AND COST MODELLING OF THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Péter Bihari

    2010-01-01

    Full Text Available The proper characterization of energy suppliers is one of the most important components in the modelling of the supply/demand relations of the electricity market. Power generation capacity i. e. power plants constitute the supply side of the relation in the electricity market. The supply of power stations develops as the power stations attempt to achieve the greatest profit possible with the given prices and other limitations. The cost of operation and the cost of load increment are thus the most important characteristics of their behaviour on the market. In most electricity market models, however, it is not taken into account that the efficiency of a power station also depends on the level of the load, on the type and age of the power plant, and on environmental considerations. The trade in electricity on the free market cannot rely on models where these essential parameters are omitted. Such an incomplete model could lead to a situation where a particular power station would be run either only at its full capacity or else be entirely deactivated depending on the prices prevailing on the free market. The reality is rather that the marginal cost of power generation might also be described by a function using the efficiency function. The derived marginal cost function gives the supply curve of the power station. The load level dependent efficiency function can be used not only for market modelling, but also for determining the pollutant and CO2 emissions of the power station, as well as shedding light on the conditions for successfully entering the market. Based on the measurement data our paper presents mathematical models that might be used for the determination of the load dependent efficiency functions of coal, oil, or gas fuelled power stations (steam turbine, gas turbine, combined cycle and IC engine based combined heat and power stations. These efficiency functions could also contribute to modelling market conditions and determining the

  1. Proceedings of a Topical Meeting On Small Scale Geothermal Power Plants and Geothermal Power Plant Projects

    Energy Technology Data Exchange (ETDEWEB)

    None

    1986-02-12

    These proceedings describe the workshop of the Topical Meeting on Small Scale Geothermal Power Plants and Geothermal Power Plant Projects. The projects covered include binary power plants, rotary separator, screw expander power plants, modular wellhead power plants, inflow turbines, and the EPRI hybrid power system. Active projects versus geothermal power projects were described. In addition, a simple approach to estimating effects of fluid deliverability on geothermal power cost is described starting on page 119. (DJE-2005)

  2. External costs of silicon carbide fusion power plants compared to other advanced generation technologies

    Energy Technology Data Exchange (ETDEWEB)

    Lechon, Y. E-mail: yolanda.lechon@ciemat.es; Cabal, H.; Saez, R.M.; Hallberg, B.; Aquilonius, K.; Schneider, T.; Lepicard, S.; Ward, D.; Hamacher, T.; Korhonen, R

    2003-09-01

    This study was performed in the framework of the Socio-Economic Research on Fusion (SERF3), which is jointly conducted by Euratom and the fusion associations. Assessments of monetarized external impacts of the fusion fuel-cycle were previously performed (SERF1 and SERF2). Three different power plant designs were studied, with the main difference being the structural materials and cooling system used. In this third phase of the SERF project the external costs of three additional fusion power plant models using silicon carbide as structural material have been analysed. A comparison with other advanced generation technologies expected to be in use around 2050, when the first fusion power plant would be operative, has also been performed. These technologies include advanced fossil technologies, such as Natural Gas Combined Cycle, Pressurised Fluidised Bed Combustion and Integrated Gasification Combined Cycle with carbon sequestration technologies; fuel cells and renewable technologies including geothermal energy, wind energy and photovoltaic systems with energy storage devices. Fusion power plants using silicon carbide as structural material have higher efficiencies than plants using steel and this fact has a very positive effect on the external costs per kW h. These external costs are in the lowest range of the external costs of advanced generation technologies indicating the outstanding environmental performance of fusion power.

  3. Center for Hypersonic Combined Cycle Flow Physics

    Science.gov (United States)

    2015-03-24

    team of expert experimentalists and numerical and chemical kinetic modelers. Flowfields were examined in the turbine /ramjet dual inlet mode transition...at the University of Virginia for extensive data acquisition using various techniques, including OH PLIF, CARS , TDLAS, TDLAT and SPIV. It was...SUBJECT TERMS Hypersonic combined cycle propulsion, turbine /ram dual-inlet transition, ram/scram dual-mode transition, hypervelocity regime, RANS, Hybrid

  4. 76 FR 20624 - Oglethorpe Power Corporation: Proposed Biomass Power Plant

    Science.gov (United States)

    2011-04-13

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF AGRICULTURE Rural Utilities Service Oglethorpe Power Corporation: Proposed Biomass Power Plant AGENCY: Rural... Corporation (Oglethorpe) for the construction of a 100 megawatt (MW) biomass plant and related...

  5. System-Level Value of a Gas Engine Power Plant in Electricity and Reserve Production

    Directory of Open Access Journals (Sweden)

    Antti Alahäivälä

    2017-07-01

    Full Text Available Power systems require a certain amount of flexibility to meet varying demand and to be able to cope with unexpected events, and this requirement is expected to increase with the emergence of variable power generation. In this paper, we focus on gas engine power plant technology and the beneficial influence its flexible operation can have on a power system. The study introduces the concept of a combined-cycle gas engine power plant (CCGE, which comprises a combination of several gas-fired combustion engines and a steam turbine. The operation of CCGE is then comprehensively analyzed in electricity and reserve production in the South African power system and compared with combined-cycle gas turbine (CCGT technology. Even though CCGE is a form of technology that has already been commercialized, it is rarely considered as a source of flexibility in the academic research. That is the notion providing the motivation for this study. Our core contribution is to show that the flexibility of CCGE can be valuable in power systems. The methodology is based on the unit-level model of the studied system and the solving of a day-ahead unit commitment problem for each day of the simulated 11-year period. The simulation studies reveal how a CCGE is able to offer system flexibility to follow hourly load variations and capacity to provide reserve power effectively.

  6. Advanced Coordinating Control System for Power Plant

    Institute of Scientific and Technical Information of China (English)

    WU Peng; WEI Shuangying

    2006-01-01

    The coordinating control system is popular used in power plant. This paper describes the advanced coordinating control by control methods and optimal operation, introduces their principals and features by using the examples of power plant operation. It is wealthy for automation application in optimal power plant operation.

  7. Combined cycles, impacts of technological requirements; Ciclos combinados, impactos de requerimientos tecnologicos

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Santalo, Jose Miguel [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    The fundamental growth of the Mexican electrical sector for the next ten years is planned on base of the installation of 20 thousand Mw plants of combined cycle. This article presents an analysis of the impact of these power stations finding out that the power stations of combined cycle are at the moment cheaper - from 600 to 700 dollars by installed kW- than the alternative coal options or fuel oil, that are in the range of 900 to 1200 dollars per kW, in addition to which the time required for their construction is shorter. [Spanish] El crecimiento fundamental del sector electrico mexicano para los proximos diez anos esta planeado con base en la instalacion de 20 mil Mw de plantas de ciclo combinado. Este articulo presenta un analisis del impacto de dichas centrales encontrando que las centrales de ciclo combinado actualmente resultan mas baratas - de 600 a 700 dolares por kW instalado - que las opciones alternativas de carbon o combustoleo que estan en el rango de 900 a 1200 dolares por kW, ademas de que los tiempos requeridos para su construccion son menores.

  8. Power Plants, Steam and Gas Turbines WebQuest

    Directory of Open Access Journals (Sweden)

    Carlos Ulloa

    2012-10-01

    Full Text Available A WebQuest is an Internet-based and inquiry-oriented learning activity. The aim of this work is to outline the creation of a WebQuest entitled “Power Generation Plants: Steam and Gas Turbines.” This is one of the topics covered in the course “Thermodynamics and Heat Transfer,” which is offered in the second year of Mechanical Engineering at the Defense University Center at the Naval Academy in Vigo, Spain. While participating in the activity, students will be divided into groups of no more than 10 for seminars. The groups will create PowerPoint presentations that include all of the analyzed aspects. The topics to be discussed during the workshop on power plant turbines are the: (1 principles of operation; (2 processes involved; (3 advantages and disadvantages; (4 efficiency; (5 combined cycle; and (6 transversal competences, such as teamwork, oral and written presentations, and analysis and synthesis of information. This paper presents the use of Google Sites as a guide to the WebQuest so that students can access all information online, including instructions, summaries, resources, and information on qualifications.

  9. Modelling of nuclear power plant decommissioning financing.

    Science.gov (United States)

    Bemš, J; Knápek, J; Králík, T; Hejhal, M; Kubančák, J; Vašíček, J

    2015-06-01

    Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article also presents methodology of allocation of future decommissioning costs to the running costs of nuclear power plant in the form of fee imposed on each megawatt hour generated. The application of the methodology is presented in the form of a case study on a new nuclear power plant with installed capacity 1000 MW.

  10. Chemistry in power plants 2011; Chemie im Kraftwerk 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    Within the VGB Powertech conference from 25th to 27th October, 2011, in Munich (Federal Republic of Germany), the following lectures and poster contributions were presented: (1) The revised VGB standard for water-steam-cycle Chemistry; (2) Switchover from neutral operation to oxygen treatment at the power station Stuttgart-Muenster of EnBW Kraftwerke AG; (3) Steam contamination with degradation products of organic matters present in the feedwater of the Lanxess-Rubber cogeneration plant; (4) Laboratory scale on-line noble metal deposition experiments simulating BWR plant conditions; (5) Building a new demin installation for the power plant EPZ in Borssele; (6) Replacement of the cooling tower installations in the nuclear power plant Goesgen-Daenien AG; (7) Aging of IEX resins in demin plants - Cost optimisation by adaptation of regenerants; (8) The largest DOW trademark EDI System at a combined cycled plant in Europe; (9) Upgrading river Main water to boiler feed water - Experiences with ultrafiltration; (10) Experiences with treatment of the water-steam-cycle in the RDF power plant Nehlsen Stavenhagen with film-forming amines; (11) Comparative modelling of the bubbles thermal collapse and cavitations for estimation of bubbles collapse influence; (12) Overcoming the steam quality - issues from an HRSG for the production of process steam; (13) Legionella - new requirements for power plant operation; (14) How the right chemistry in the FGD helps to improve the removal in the waste water treatment plant; (15) High efficiency filtration in dry/semi-dry FGD plants; (16) Expanding the variety of renewable fuels in the biomass power plant Timelkam using the chemical input control; (17) Corrosion, operating experiences and process improvements to increase the availability and operating time of the biomass power plant Timelkam; (18) The influence of temperature on the measurement of the conductivity of highly diluted solutions; (19) A multiparameter instrumentation approach

  11. Effective ways to modernize outdated coal heat power plants

    Science.gov (United States)

    Suchkov, S. I.; Kotler, V. R.; Batorshin, V. A.

    2016-12-01

    An analysis of the state of equipment of 72 outdated coal HPP (heat power plants) of a total capacity 14.3 GW with steam parameters before the turbines p before ≤ 9 MPa, t before = 420-540°C was performed. The equipment is characterized by a considerably low efficiency factor, even if it were converted to burning the natural gas, and by increased release of harmful substances. However, on the most part of the considered HPP, the steam turbines, unlike the boilers, have thus far retained the operation applicability and satisfactory reliability of performance. The analysis has shown that it makes sense to effectively modernize the outdated coal HPP by transformation of their equipment into combined-cycle plant (CCP) with coal gasification, which has high economic and ecological indicators due to thermodynamic advantage of the combined cycle and simpler purification of the generator gas in the process under pressure. As the most rational way of this transformation, the one was recognized wherein—instead of the existing boiler (boilers) or parallel to it—a gasification and gas turbine system is installed with a boiler-utilizer (BU), from which steam is fed to the HPP main steam pipe. In doing this, the basic part of the power station equipment persists. In the world, this kind of reconstruction of steam power equipment is applied widely and successfully, but it is by use of natural gas for the most part. It is reasonable to use the technology developed at Heat Engineering Research Institute (HERI) of hearth-steam gasification of coal and high-temperature purification of the generator gas. The basic scheme and measures on implementation of this method for modernization of outdated coal HPP is creation of CCP with blast-furnace of coal on the basis of accessible and preserved HPP equipment. CCP power is 120 MW, input-output ratio (roughly) 44%, emissions of hazardous substances are 5 mg/MJ dust, 20-60 mg/MJ SO2, and 50-100 mg/MJ NO x . A considerable decrease of

  12. Sabotage at Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Purvis, James W.

    1999-07-21

    Recently there has been a noted worldwide increase in violent actions including attempted sabotage at nuclear power plants. Several organizations, such as the International Atomic Energy Agency and the US Nuclear Regulatory Commission, have guidelines, recommendations, and formal threat- and risk-assessment processes for the protection of nuclear assets. Other examples are the former Defense Special Weapons Agency, which used a risk-assessment model to evaluate force-protection security requirements for terrorist incidents at DOD military bases. The US DOE uses a graded approach to protect its assets based on risk and vulnerability assessments. The Federal Aviation Administration and Federal Bureau of Investigation conduct joint threat and vulnerability assessments on high-risk US airports. Several private companies under contract to government agencies use formal risk-assessment models and methods to identify security requirements. The purpose of this paper is to survey these methods and present an overview of all potential types of sabotage at nuclear power plants. The paper discusses emerging threats and current methods of choice for sabotage--especially vehicle bombs and chemical attacks. Potential consequences of sabotage acts, including economic and political; not just those that may result in unacceptable radiological exposure to the public, are also discussed. Applicability of risk-assessment methods and mitigation techniques are also presented.

  13. Reassessing the Efficiency Penalty from Carbon Capture in Coal-Fired Power Plants.

    Science.gov (United States)

    Supekar, Sarang D; Skerlos, Steven J

    2015-10-20

    This paper examines thermal efficiency penalties and greenhouse gas as well as other pollutant emissions associated with pulverized coal (PC) power plants equipped with postcombustion CO2 capture for carbon sequestration. We find that, depending on the source of heat used to meet the steam requirements in the capture unit, retrofitting a PC power plant that maintains its gross power output (compared to a PC power plant without a capture unit) can cause a drop in plant thermal efficiency of 11.3-22.9%-points. This estimate for efficiency penalty is significantly higher than literature values and corresponds to an increase of about 5.3-7.7 US¢/kWh in the levelized cost of electricity (COE) over the 8.4 US¢/kWh COE value for PC plants without CO2 capture. The results follow from the inclusion of mass and energy feedbacks in PC power plants with CO2 capture into previous analyses, as well as including potential quality considerations for safe and reliable transportation and sequestration of CO2. We conclude that PC power plants with CO2 capture are likely to remain less competitive than natural gas combined cycle (without CO2 capture) and on-shore wind power plants, both from a levelized and marginal COE point of view.

  14. A critical review on energy, exergy, exergoeconomic and economic (4-E analysis of thermal power plants

    Directory of Open Access Journals (Sweden)

    Ravinder Kumar

    2017-02-01

    Full Text Available The growing energy supply, demand has created an interest towards the plant equipment efficiency and the optimization of existing thermal power plants. Also, a thermal power plant dependency on fossil fuel makes it a little bit difficult, because of environmental impacts has been always taken into consideration. At present, most of the power plants are going to be designed by the energetic performance criterion which is based on the first law of thermodynamics. Sometimes, the system energy balance is not sufficient for the possible finding of the system imperfections. Energy losses taking place in a system can be easily determined by using exergy analysis. Hence, it is a powerful tool for the measurement of energy quality, thereby helps to make complex thermodynamic systems more efficient. Nowadays, economic optimization of plant is also a big problem for researchers because of the complex nature. At a viewpoint of this, a comprehensive literature review over the years of energy, exergy, exergoeconomic and economic (4-E analysis and their applications in thermal power plants stimulated by coal, gas, combined cycle and cogeneration system have been done thoroughly. This paper is addressed to those researchers who are doing their research work on 4-E analysis in various thermal power plants. If anyone extracts an idea for the development of the concept of 4-E analysis using this article, we will achieve our goal. This review also indicates the scope of future research in thermal power plants.

  15. Marginal costs of water savings from cooling system retrofits: a case study for Texas power plants

    Science.gov (United States)

    Loew, Aviva; Jaramillo, Paulina; Zhai, Haibo

    2016-10-01

    The water demands of power plant cooling systems may strain water supply and make power generation vulnerable to water scarcity. Cooling systems range in their rates of water use, capital investment, and annual costs. Using Texas as a case study, we examined the cost of retrofitting existing coal and natural gas combined-cycle (NGCC) power plants with alternative cooling systems, either wet recirculating towers or air-cooled condensers for dry cooling. We applied a power plant assessment tool to model existing power plants in terms of their key plant attributes and site-specific meteorological conditions and then estimated operation characteristics of retrofitted plants and retrofit costs. We determined the anticipated annual reductions in water withdrawals and the cost-per-gallon of water saved by retrofits in both deterministic and probabilistic forms. The results demonstrate that replacing once-through cooling at coal-fired power plants with wet recirculating towers has the lowest cost per reduced water withdrawals, on average. The average marginal cost of water withdrawal savings for dry-cooling retrofits at coal-fired plants is approximately 0.68 cents per gallon, while the marginal recirculating retrofit cost is 0.008 cents per gallon. For NGCC plants, the average marginal costs of water withdrawal savings for dry-cooling and recirculating towers are 1.78 and 0.037 cents per gallon, respectively.

  16. Efficiency of Modern Power Plants of Thermal Power Stations

    Directory of Open Access Journals (Sweden)

    B. V. Yakovlev

    2007-01-01

    Full Text Available The paper considers efficiency and prospects in development of different types of fossil-fuel power plants – gas turbine, steam turbine and combined (gas and steam cycles.The paper provides information on plant selection, fuel consumption, specific output cost. It describes main advantages of various power plants.

  17. Hybrid wind-power-distillation plant

    OpenAIRE

    Ninić Neven; Klarin Branko; Tolj Ivan

    2012-01-01

    This paper reports and elaborates on the idea of a solar distiller and an offshore wind power plant operating together. The subject under discussion is a single-stage solar distillation plant with vaporization, using adiabatic expansion in the gravitational field inside a wind power plant supporting column. This scheme divides investment costs for electric power and distillate production. In the region of the Adriatic Sea, all electric power produced could be “converted” to hydrogen usi...

  18. Advances in Model-Based Design of Flexible and Prompt Energy Systems -- The CO2 Capture Plant at the Buggenum IGCC Power Station as a Test Case

    NARCIS (Netherlands)

    Trapp, C.

    2014-01-01

    Pre-combustion CO2 capture applied to integrated gasification combined cycle (IGCC) power plants is a promising technical solution to reduce CO2 emissions due to fossil-fuelled electricity generation in order to meet environmental targets in a carbon-constrained future. The pre-combustion capture

  19. Advances in Model-Based Design of Flexible and Prompt Energy Systems -- The CO2 Capture Plant at the Buggenum IGCC Power Station as a Test Case

    NARCIS (Netherlands)

    Trapp, C.

    2014-01-01

    Pre-combustion CO2 capture applied to integrated gasification combined cycle (IGCC) power plants is a promising technical solution to reduce CO2 emissions due to fossil-fuelled electricity generation in order to meet environmental targets in a carbon-constrained future. The pre-combustion capture pr

  20. The potential future of high-temperature gas turbines in power plants; Zukunftsperspektiven fuer die Hochtemperatur-Gasturbine im Kraftwerksbau

    Energy Technology Data Exchange (ETDEWEB)

    Vogeler, Konrad [Technische Univ. Dresden (Germany). Inst. fuer Stroemungsmechanik

    2011-07-01

    The future role of the high-temperature gas turbine is discussed. Due to environmental and cost pressure, the mix of primary energy sources will be changing. CO{sub 2} capture and storage (CCS) will have major impact on technical equipment and operation cost of fossil-fired power plants. If fuel consumption has to be minimised, the efficiency of power plants will be the key to success. The paper discusses the main parameters which influence efficiency and power output for an open and combined cycle gas turbine cycle. State-of-the-art materials and manufacturing methods promise potentials to increase efficiency even further. (orig.)

  1. Thermal power plant design and operation

    CERN Document Server

    Sarkar, Dipak

    2015-01-01

    Thermal Power Plant: Design and Operation deals with various aspects of a thermal power plant, providing a new dimension to the subject, with focus on operating practices and troubleshooting, as well as technology and design. Its author has a 40-long association with thermal power plants in design as well as field engineering, sharing his experience with professional engineers under various training capacities, such as training programs for graduate engineers and operating personnel. Thermal Power Plant presents practical content on coal-, gas-, oil-, peat- and biomass-fueled thermal power

  2. Nuclear power plant operation 2016. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2017-05-15

    A report is given on the operating results achieved in 2016, events important to plant safety, special and relevant repair, and retrofit measures from nuclear power plants in Germany. Reports about nuclear power plants in Belgium, Finland, the Netherlands, Switzerland, and Spain will be published in a further issue.

  3. Mercury emissions from geothermal power plants.

    Science.gov (United States)

    Robertson, D E; Crecelius, E A; Fruchter, J S; Ludwick, J D

    1977-06-03

    Geothermal steam used for power production contains significant quantities of volatile mercury. Much of this mercury escapes to the atmosphere as elemental mercury vapor in cooling tower exhausts. Mercury emissions from geothermal power plants, on a per megawatt (electric) basis, are comparable to releases from coal-fired power plants.

  4. Conceptual design study of a coal gasification combined-cycle powerplant for industrial cogeneration

    Science.gov (United States)

    Bloomfield, H. S.; Nelson, S. G.; Straight, H. F.; Subramaniam, T. K.; Winklepleck, R. G.

    1981-01-01

    A conceptual design study was conducted to assess technical feasibility, environmental characteristics, and economics of coal gasification. The feasibility of a coal gasification combined cycle cogeneration powerplant was examined in response to energy needs and to national policy aimed at decreasing dependence on oil and natural gas. The powerplant provides the steam heating and baseload electrical requirements while serving as a prototype for industrial cogeneration and a modular building block for utility applications. The following topics are discussed: (1) screening of candidate gasification, sulfur removal and power conversion components; (2) definition of a reference system; (3) quantification of plant emissions and waste streams; (4) estimates of capital and operating costs; and (5) a procurement and construction schedule. It is concluded that the proposed powerplant is technically feasible and environmentally superior.

  5. Thermal Impact of Operating Conditions on the Performance of a Combined Cycle Gas Turbine

    Directory of Open Access Journals (Sweden)

    Thamir K. Ibrahim

    2012-08-01

    Full Text Available The combined cycle gas-turbine (CCGT power plant is a highly developed technology which generates electricalpower at high efficiencies. The first law of thermodynamics is used for energy analysis of the performance of theCCGT plant. The effects of varying the operating conditions (ambient temperature, compression ratio, turbine inlettemperature, isentropic compressor and turbine efficiencies, and mass flow rate of steam on the performance of theCCGT (overall efficiency and total output power were investigated. The programming of the performance model forCCGT was developed utilizing MATLAB software. The simulation results for CCGT show that the overall efficiencyincreases with increases in the compression ratio and turbine inlet temperature and with decreases in ambienttemperature. The total power output increases with increases in the compression ratio, ambient temperature, andturbine inlet temperature. The peak overall efficiency was reached with a higher compression ratio and low ambienttemperature. The overall efficiencies for CCGT were very high compared to the thermal efficiency of GT plants. Theoverall thermal efficiency of the CCGT quoted was around 57%; hence, the compression ratios, ambient temperature,turbine inlet temperature, isentropic compressor and turbine efficiencies, and mass flow rate of steam have a stronginfluence on the overall performance of the CCGT cycle.

  6. Optimizing power plant cycling operations while reducing generating plant damage and costs

    Energy Technology Data Exchange (ETDEWEB)

    Lefton, S.A.; Besuner, P.H.; Grimsrud, P. [Aptech Engineering Services, Inc., Sunnyvale, CA (United States); Bissel, A. [Electric Supply Board, Dublin (Ireland)

    1998-12-31

    This presentation describes a method for analyzing, quantifying, and minimizing the total cost of fossil, combined cycle, and pumped hydro power plant cycling operation. The method has been developed, refined, and applied during engineering studies at some 160 units in the United States and 8 units at the Irish Electric Supply Board (ESB) generating system. The basic premise of these studies was that utilities are underestimating the cost of cycling operation. The studies showed that the cost of cycling conventional boiler/turbine fossil power plants can range from between $2,500 and $500,000 per start-stop cycle. It was found that utilities typically estimate these costs by factors of 3 to 30 below actual costs and, thus, often significantly underestimate their true cycling costs. Knowledge of the actual, or total, cost of cycling will reduce power production costs by enabling utilities to more accurately dispatch their units to manage unit life expectancies, maintenance strategies and reliability. Utility management responses to these costs are presented and utility cost savings have been demonstrated. (orig.) 7 refs.

  7. Thermal and nuclear power plants: Competitiveness in the new economic conditions

    Science.gov (United States)

    Aminov, R. Z.; Shkret, A. F.; Garievskii, M. V.

    2017-05-01

    In recent years, the conditions of development and functionality of power generating assets have notably changed. Considering the decline in the price of hydrocarbon fuel on the global market, the efficiency of combined-cycle gas-turbine plants in the European part of Russia is growing in comparison with nuclear power plants. Capital investments in the construction of nuclear power plants have also increased as a result of stiffening the safety requirements. In view of this, there has been an increasing interest in exploration of effective lines of development of generating assets in the European part of Russia, taking consideration of the conditions that may arise in the nearest long-term perspective. In particular, the assessment of comparative efficiency of developing combined-cycle gas-turbine plants (operating on natural gas) in the European part of Russia and nuclear power plants is of academic and practical interest. In this article, we analyze the trends of changes in the regional price of hydrocarbon fuel. Using the prognosis of net-weighted import prices of natural gas in Western European countries—prepared by the International Energy Agency (IEA) and the Energy Research Institute of the Russian Academy of Sciences (ERIRAS)—the prices of natural gas in the European part of Russia equilibrated with import prices of this heat carrier in Western Europe were determined. The methodology of determining the comparative efficiency of combined-cycle gas turbine plants (CCGT) and nuclear power plants (NPP) were described; based on this, the possible development of basic CCGTs and NPPs with regard to the European part of Russia for various scenarios in the prognosis of prices of gaseous fuel in a broad range of change of specific investments in the given generating sources were assessed, and the extents of their comparative efficiency were shown. It was proven that, at specific investments in the construction of new NPPs in the amount of 5000 dollars/kW, nuclear

  8. Uncertainty analysis of integrated gasification combined cycle systems based on Frame 7H versus 7F gas turbines.

    Science.gov (United States)

    Zhu, Yunhua; Frey, H Christopher

    2006-12-01

    Integrated gasification combined cycle (IGCC) technology is a promising alternative for clean generation of power and coproduction of chemicals from coal and other feedstocks. Advanced concepts for IGCC systems that incorporate state-of-the-art gas turbine systems, however, are not commercially demonstrated. Therefore, there is uncertainty regarding the future commercial-scale performance, emissions, and cost of such technologies. The Frame 7F gas turbine represents current state-of-practice, whereas the Frame 7H is the most recently introduced advanced commercial gas turbine. The objective of this study was to evaluate the risks and potential payoffs of IGCC technology based on different gas turbine combined cycle designs. Models of entrained-flow gasifier-based IGCC systems with Frame 7F (IGCC-7F) and 7H gas turbine combined cycles (IGCC-7H) were developed in ASPEN Plus. An uncertainty analysis was conducted. Gasifier carbon conversion and project cost uncertainty are identified as the most important uncertain inputs with respect to system performance and cost. The uncertainties in the difference of the efficiencies and costs for the two systems are characterized. Despite uncertainty, the IGCC-7H system is robustly preferred to the IGCC-7F system. Advances in gas turbine design will improve the performance, emissions, and cost of IGCC systems. The implications of this study for decision-making regarding technology selection, research planning, and plant operation are discussed.

  9. Combined gas/steam turbine power plants with coal fired steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, H.J.; Weirich, P.H. [ABB Kraftwerke AG, Mannheim (Germany)

    1994-12-31

    The combination of coal fired steam power plants with natural gas fired gas turbines results in an essential efficiency increase, up to 50%, requiring a portion of around one third of the fuel heat input in form of natural gas. There are two basic types of circuit arrangements in this category: in a topping process the gas turbine is connected to the steam generator on the gas side, and in a compound cycle power plant gas turbine and steam circuit are connected to each other on the water/steam side via a heat recovery steam generator. If comparable design parameters are applied slightly higher plant efficiencies can be obtained with the topping process. With respect to a higher power plant availability it is possible to operate both types of circuit arrangement without gas turbine. The specific investment cost of such combined cycle power plants is lower than that of corresponding steam power plants. Hence, they can represent economical solutions as far as the price ratio between natural gas and coal is not extremely high. In ecological respects, the advantage of this combination is a reduction of the specific CO{sub 2} emission by around 20-25%, compared with pure steam power plants. 1 ref., 9 figs., 2 tabs.

  10. Nuclear power plant cable materials :

    Energy Technology Data Exchange (ETDEWEB)

    Celina, Mathias C.; Gillen, Kenneth T; Lindgren, Eric Richard

    2013-05-01

    A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostly inert aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on

  11. Modern geothermal power: Binary cycle geothermal power plants

    Science.gov (United States)

    Tomarov, G. V.; Shipkov, A. A.

    2017-04-01

    In the second part of the review of modern geothermal power plant technologies and equipment, a role, a usage scale, and features of application of binary cycle plants in the geothermal economy are considered. Data on the use of low-boiling fluids, their impact on thermal parameters and performance of geothermal binary power units are presented. A retrospective of the use of various low-boiling fluids in industrial binary power units in the world since 1965 is shown. It is noted that the current generating capacity of binary power units running on hydrocarbons is equal to approximately 82.7% of the total installed capacity of all the binary power units in the world. At the same time over the past 5 years, the total installed capacity of geothermal binary power units in 25 countries increased by more than 50%, reaching nearly 1800 MW (hereinafter electric power is indicated), by 2015. A vast majority of the existing binary power plants recovers heat of geothermal fluid in the range of 100-200°C. Binary cycle power plants have an average unit capacity of 6.3 MW, 30.4 MW at single-flash power plants, 37.4 MW at double-flash plants, and 45.4 MW at power plants working on superheated steam. The largest binary cycle geothermal power plants (GeoPP) with an installed capacity of over 60 MW are in operation in the United States and the Philippines. In most cases, binary plants are involved in the production process together with a steam cycle. Requirements to the fluid ensuring safety, reliability, and efficiency of binary power plants using heat of geothermal fluid are determined, and differences and features of their technological processes are shown. Application of binary cycle plants in the technological process of combined GeoPPs makes it possible to recover geothermal fluid more efficiently. Features and advantages of binary cycle plants using multiple fluids, including a Kalina Cycle, are analyzed. Technical characteristics of binary cycle plants produced by various

  12. TS Power Plant, Eureka County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, R. [DTE Energy Services (United States)

    2008-10-15

    Not all coal-fired power plants are constructed by investor-owned utilities or independent power producers selling to wholesale markets. When Newmont Mining Corp. recognised that local power supplies were inadequate and too expensive to meet long-term electricity needs for its major gold- and copper-mining operations in northern Nevada, it built its own generation. What is more, Newmont's privately owned 200-MW net coal-fired plant features power plant technologies that will surely become industry standards. Newmont's investment in power and technology is also golden: the capital cost will be paid back in about eight years. 4 figs.

  13. Future requirements for fossil power plants

    Directory of Open Access Journals (Sweden)

    Spliethoff H.

    2013-06-01

    Full Text Available The fast increasing installation of technologies to convert renewable energy into power influences the operation of conventional power plants. New requirements on the technology, on the operation and on the economic have to be considered for already running and future power plants. Currently, first experiences with such a production and market situation are available. Technologies are discussed to store power and to reduce CO2 emissions. New compensation models are necessary to enable economic operation of fossil power plants in base load. This article gives a short review about available technologies and future challenges.

  14. FUEL CELL/MICRO-TURBINE COMBINED CYCLE

    Energy Technology Data Exchange (ETDEWEB)

    Larry J. Chaney; Mike R. Tharp; Tom W. Wolf; Tim A. Fuller; Joe J. Hartvigson

    1999-12-01

    A wide variety of conceptual design studies have been conducted that describe ultra-high efficiency fossil power plant cycles. The most promising of these ultra-high efficiency cycles incorporate high temperature fuel cells with a gas turbine. Combining fuel cells with a gas turbine increases overall cycle efficiency while reducing per kilowatt emissions. This study has demonstrated that the unique approach taken to combining a fuel cell and gas turbine has both technical and economic merit. The approach used in this study eliminates most of the gas turbine integration problems associated with hybrid fuel cell turbine systems. By using a micro-turbine, and a non-pressurized fuel cell the total system size (kW) and complexity has been reduced substantially from those presented in other studies, while maintaining over 70% efficiency. The reduced system size can be particularly attractive in the deregulated electrical generation/distribution environment where the market may not demand multi-megawatt central stations systems. The small size also opens up the niche markets to this high efficiency, low emission electrical generation option.

  15. Nuclear Power Plant Module, NPP-1: Nuclear Power Cost Analysis.

    Science.gov (United States)

    Whitelaw, Robert L.

    The purpose of the Nuclear Power Plant Modules, NPP-1, is to determine the total cost of electricity from a nuclear power plant in terms of all the components contributing to cost. The plan of analysis is in five parts: (1) general formulation of the cost equation; (2) capital cost and fixed charges thereon; (3) operational cost for labor,…

  16. Status of the Combined Cycle Engine Rig

    Science.gov (United States)

    Saunders, Dave; Slater, John; Dippold, Vance

    2009-01-01

    Status for the past year is provided of the turbine-based Combined-Cycle Engine (CCE) Rig for the hypersonic project. As part of the first stage propulsion of a two-stage-to-orbit vehicle concept, this engine rig is designed with a common inlet that supplies flow to a turbine engine and a dual-mode ramjet / scramjet engine in an over/under configuration. At Mach 4 the inlet has variable geometry to switch the airflow from the turbine to the ramjet / scramjet engine. This process is known as inlet mode-transition. In addition to investigating inlet aspects of mode transition, the rig will allow testing of turbine and scramjet systems later in the test series. Fully closing the splitter cowl "cocoons" the turbine engine and increases airflow to the scramjet duct. The CCE Rig will be a testbed to investigate integrated propulsion system and controls technology objectives. Four phases of testing are planned to 1) characterize the dual inlet database, 2) collect inlet dynamics using system identification techniques, 3) implement an inlet control to demonstrate mode-transition scenarios and 4) demonstrate integrated inlet/turbine engine operation through mode-transition. Status of the test planning and preparation activities is summarized with background on the inlet design and small-scale testing, analytical CFD predictions and some details of the large-scale hardware. The final stages of fabrication are underway.

  17. Wood-gas / natural-gas combined-cycle power station for Switzerland - Potential and estimation of financial viability; Holzgas/Erdgas-Kombikraftwerk fuer die Schweiz: Potenzial und Wirtschaftlichkeitsabschaetzung. Input-Papier fuer die Stromangebots-Perspektiven 2035 des Bundesamts fuer Energie

    Energy Technology Data Exchange (ETDEWEB)

    Nussbaumer, T.

    2005-07-01

    This paper was produced as an input to the Swiss Confederation's 'Electricity Perspectives 2035' study made by the Swiss Federal Office of Energy (SFOE). A concept for the combined use of wood and natural gas in a combined-cycle power station is presented. The gasification of wood to provide fuel for the gas turbines and waste-heat boilers of such power stations is proposed as an alternative to just burning wood to provide heat for steam generators. Figures are quoted on the quantities of biomass and wood usable for energy applications in Switzerland. The energetic and financial efficiencies of wood-powered generation of heat and electricity are examined, as are the investments necessary and the costs incurred. Comparisons are presented between wood from forests, sawmill-wastes, scrap wood and natural gas as fuels.

  18. Nuclear Power Plant Lifetime Management Study (I)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Yull; Jeong, Ill Seok; Jang, Chang Heui; Song, Taek Ho; Song, Woo Young [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Jin, Tae Eun [Korea Power Engineering Company Consulting and Architecture Engineers, (Korea, Republic of); Kim, Woo Chul [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    As the operation-year of nuclear power plant increases and finding sites for new nuclear power plant becomes harder, a comprehensive and systematic nuclear plant lifetime management(PLIM) program including life extension has to be established for stable and safe supply of electricity. A feasibility study was conducted to systematically evaluate technical, economic and regulatory aspect of plant lifetime managements and plant life extension for Kori-1 nuclear power plant. For technical evaluation of nuclear power plant, 13 major components were selected for lifetime evaluation by screening system. structure, and components(SSCs) of the plant. It was found that except reactor pressure vessel, which needs detailed integrity analysis, and low pressure turbine, which is scheduled to be replaced, 11 out of 13 major components have sufficient service life, for more than 40 years. Because domestic rules and regulations related to license renewal has not yet been written, review on the regulatory aspect of life extensions was conducted using US NRC rules and regulations. A cooperative effort with nuclear regulatory body is needed for early completion of license renewal rules and regulations. For economic evaluation of plant lifetime extension, a computer program was developed and used. It was found that 10 to 20 year of extension operation of Kori-1 nuclear power plant was proved. Based on the results, next phase of plant lifetime management program for detailed lifetime evaluation and presenting detailed implementation schedule for plant refurbishment for lifetime extension should be followed. (author). 74 refs., figs.

  19. Optimization of advenced liquid natural gas-fuelled combined cycle machinery systems for a high-speed ferry

    DEFF Research Database (Denmark)

    Tveitaskog, Kari Anne; Haglind, Fredrik

    2012-01-01

    . Furthermore, practical and operational aspects of using these three machinery systems for a high-speed ferry are discussed. Two scenarios are evaluated. The first scenario evaluates the combined cycles with a given power requirement, optimizing the combined cycle while operating the gas turbine at part load...

  20. Ammonia in power plant emission

    Science.gov (United States)

    Hammerich, Mads; Henningsen, J. O.; Olafsson, Ari

    1990-08-01

    Ammonia monitoring is needed in most schemes for denitrification of power plant emission. In the PALAMON system we use a 500 MHz tunable, single mode, single line, CO2 laser as light source for a low pressure, high temperature, photoacoustic cell. With this cell we can resolve the sR(5,O) line of the ammonia spectrum, and suppress the interfering C02(9R30) absorption line down to a lppm NH3 detection limit. The validity of the measured ammonia concentrations is strongly dependent on details of the sampling system and on the reliability of the calibration routines. In particular calibration with certified mixtures of NH3:N2 has proved insufficient due to the multiple and long time constants caused by adsorption of ammonia to different materials in the system. Presence of water vapor in the gas greatly reduces these time constants. Therefore a number of methods for simple production of moist calibration gases from macroscopic amounts of NH3 are applied. The calibrations are translated to response from an easily managable absorber in order to allow automated recalibration of the photoacoustic response. Data from a field test of the system, and calibration data will be presented.

  1. Discussion on Thermodynamic Performance Acceptable Test of Combined Cycle Power Plant%浅论联合循环热力性能的验收试验

    Institute of Scientific and Technical Information of China (English)

    焦树建

    2005-01-01

    Summarized the pivotal during the therwodynamic performance acceptable test of gas turbine compiUed cycle,tO insuring the availability of the test.%概要地讨论了燃气蒸汽联合循环热力性能验收试验中必须严格把握的几个关键环节,以确保试验结果的有效性。

  2. Predicting the indicators of the safety performance monitoring after implementation of integrated management system (IMS in a combined cycle power plant in Yazd city

    Directory of Open Access Journals (Sweden)

    F. Laal

    2015-07-01

    .Conclusion: Findings show that Cubic regression can be an appropriate to olforinvestigating the indicators trends and for their predictionin planning and monitoring the performance ofsafety unitso that the decision-making for determining the priority of organizations’ safety programs would be facilitated.

  3. Aspen Process Flowsheet Simulation Model of a Battelle Biomass-Based Gasification, Fischer-Tropsch Liquefaction and Combined-Cycle Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    None

    1998-10-30

    This study was done to support the research and development program of the National Renewable Energy Laboratory (NREL) in the thermochemical conversion of biomass to liquid transportation fuels using current state-of-the-art technology. The Mitretek study investigated the use of two biomass gasifiers; the RENUGAS gasifier being developed by the Institute of Gas Technology, and the indirectly heated gasifier being developed by Battelle Columbus. The Battelle Memorial Institute of Columbus, Ohio indirectly heated biomass gasifier was selected for this model development because the syngas produced by it is better suited for Fischer-Tropsch synthesis with an iron-based catalyst for which a large amount of experimental data are available. Bechtel with Amoco as a subcontractor developed a conceptual baseline design and several alternative designs for indirect coal liquefaction facilities. In addition, ASPEN Plus process flowsheet simulation models were developed for each of designs. These models were used to perform several parametric studies to investigate various alternatives for improving the economics of indirect coal liquefaction.

  4. Availability Analysis of Gas Turbines Used in Power Plants

    Directory of Open Access Journals (Sweden)

    Gilberto Francisco Martha de Souza

    2009-03-01

    Full Text Available The availability of a complex system, such as a gas turbine, is strongly associated with its parts reliability and maintenance policy. That policy not only has influence on the parts’ repair time but also on the parts’ reliability affecting the system degradation and availability. This study presents a method for reliability and availability evaluation of gas turbines installed in an electric power station. The method is based on system reliability concepts, such as functional tree development, application of failure mode and effects analysis to identify critical components for improvement of system reliability, and reliability and maintainability evaluation based on a historical failure database. The method also proposes the application of Reliability Centered Maintenance concepts to improve complex system maintenance policies aimed at the reduction of unexpected failure occurrences in critical components. The method is applied to the analysis of two F series gas turbines, each with an output of 150 MW, installed in a 500 MW combined cycle power plant. The reliability and availability of the turbines are simulated based on a five-year failure database. The availability analysis shows different results for each turbine, one presenting 99% and the other 96% availability, indicating differences in their systems installation and operation.

  5. Exergetic comparison of two KRW-based IGCC power plants

    Science.gov (United States)

    Tsatsaronis, G.; Tawfik, T.; Lin, L.; Gallaspy, D. T.

    1994-04-01

    In studies supported by the U.S. Department of Energy and the Electric Power Research Institute, several design configurations of Kellogg-Rust-Westinghouse (KRW)-based Integrated Gasification-Combined-Cycle (IGCC) power plants were developed. Two of these configurations are compared here from the exergetic viewpoint. The first design configuration (case 1) uses an air-blown KRW gasifier and hot gas cleanup while the second configuration (reference case) uses an oxygen-blown KRW gasifier and cold gas cleanup. Each case uses two General Electric MS7001F advanced combustion turbines. The exergetic comparison identifies the causes of performance difference between the two cases: differences in the exergy destruction of the gasification system, the gas turbine system, and the gas cooling process, as well as differences in the exergy loss accompanying the solids to disposal stream. The potential for using (a) oxygen-blown versus air-blown-KRW gasifiers, and (b) hot gas versus cold gas cleanup processes was evaluated. The results indicate that, among the available options, an oxygen-blown KRW gasifier using in-bed desulfurization combined with an optimized hot gas cleanup process has the largest potential for providing performance improvements.

  6. Lessons learned from existing biomass power plants

    Energy Technology Data Exchange (ETDEWEB)

    Wiltsee, G.

    2000-02-24

    This report includes summary information on 20 biomass power plants, which represent some of the leaders in the industry. In each category an effort is made to identify plants that illustrate particular points. The project experiences described capture some important lessons learned that lead in the direction of an improved biomass power industry.

  7. Pre-combustion CO{sub 2} capture: Analysis of integrated reforming combined cycle

    Energy Technology Data Exchange (ETDEWEB)

    Nord, Lars Olof

    2010-06-15

    This thesis presents processes for reducing CO{sub 2} emissions from natural gas (NG) power plants, which could help attenuate the rise in atmospheric temperature. Objectives for the thesis work were process design and integration of NG pre-combustion CO{sub 2} capture plants, and evolution, through process simulation, of the concepts. An important aspect of the evaluation was investigation of plant flexibility, specifically off-design analysis. Contributions comprised detailed heat recovery steam generator (HRSG) design for NG pre-combustion cycles and off-design behavior of the integrated reforming combined cycle (IRCC). Additional contributions were quantification of the efficiency potential of a process, subsystem efficiency losses, and model uncertainties. The IRCC with pre-combustion CO{sub 2} capture is a process for generating power with very low CO{sub 2} emissions, typically below 100 g CO{sub 2}/net kWh electricity. This should be compared to a state-of-the-art natural gas combined cycle (NGCC) with CO{sub 2} emissions around 365 g CO{sub 2}/net kWh electricity. The IRCC process reforms natural gas to a syngas, converts the CO to CO{sub 2} in the shift reactors, separates the CO{sub 2} in the capture subsystem, and the resulting hydrogen-rich fuel is used for the gas turbine (GT) in a combined cycle setup. For the reforming of natural gas, an air-blown auto thermal reformer was selected for the processes studied. Included in the study of the IRCC were process design and integration, reliability analysis, thermodynamic analyses through process simulation, analysis of efficiency losses and efficiency potential, and uncertainty analysis. As part of the design process, HRSG design proved important. The design of an HRSG for an IRCC plant requires the ability to operate on both a hydrogen-rich fuel and on NG. Also, since a significant amount of steam is produced from the heat generated in the auto reforming process, the HRSG design differs from a design in an

  8. Optimization of CCGT power plant and performance analysis using MATLAB/Simulink with actual operational data.

    Science.gov (United States)

    Hasan, Naimul; Rai, Jitendra Nath; Arora, Bharat Bhushan

    2014-01-01

    In the Modern scenario, the naturally available resources for power generation are being depleted at an alarming rate; firstly due to wastage of power at consumer end, secondly due to inefficiency of various power system components. A Combined Cycle Gas Turbine (CCGT) integrates two cycles- Brayton cycle (Gas Turbine) and Rankine cycle (Steam Turbine) with the objective of increasing overall plant efficiency. This is accomplished by utilising the exhaust of Gas Turbine through a waste-heat recovery boiler to run a Steam Turbine. The efficiency of a gas turbine which ranges from 28% to 33% can hence be raised to about 60% by recovering some of the low grade thermal energy from the exhaust gas for steam turbine process. This paper is a study for the modelling of CCGT and comparing it with actual operational data. The performance model for CCGT plant was developed in MATLAB/Simulink.

  9. Water impacts of CO2 emission performance standards for fossil fuel-fired power plants.

    Science.gov (United States)

    Talati, Shuchi; Zhai, Haibo; Morgan, M Granger

    2014-10-21

    We employ an integrated systems modeling tool to assess the water impacts of the new source performance standards recently proposed by the U.S. Environmental Protection Agency for limiting CO2 emissions from coal- and gas-fired power plants. The implementation of amine-based carbon capture and storage (CCS) for 40% CO2 capture to meet the current proposal will increase plant water use by roughly 30% in supercritical pulverized coal-fired power plants. The specific amount of added water use varies with power plant and CCS designs. More stringent emission standards than the current proposal would require CO2 emission reductions for natural gas combined-cycle (NGCC) plants via CCS, which would also increase plant water use. When examined over a range of possible future emission standards from 1100 to 300 lb CO2/MWh gross, new baseload NGCC plants consume roughly 60-70% less water than coal-fired plants. A series of adaptation approaches to secure low-carbon energy production and improve the electric power industry's water management in the face of future policy constraints are discussed both quantitatively and qualitatively.

  10. Dynamic Frequency Response of Wind Power Plants

    DEFF Research Database (Denmark)

    Altin, Müfit

    Electricity generation from wind energy has rapidly increased for the last five years worldwide. In many countries, wind energy targets have been set in the range of 20% to 50% of all electricity generation due to the concerns of CO2 emissions, fossil fuel costs, and energy efficiency. In order...... to maintain sustainable and reliable operation of the power system for these targets, transmission system operators (TSOs) have revised the grid code requirements. Also, the TSOs are planning the future development of the power system with various wind penetration scenarios to integrate more wind power...... according to their grid codes. In these scenarios particularly with high wind power penetration cases, conventional power plants (CPPs) such as old thermal power plants are planned to be replaced with wind power plants (WPPs). Consequently, the power system stability will be affected and the control...

  11. Harmonics in a Wind Power Plant: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Preciado, V.; Madrigal, M.; Muljadi, E.; Gevorgian, V.

    2015-04-02

    Wind power generation has been growing at a very fast pace for the past decade, and its influence and impact on the electric power grid is significant. As in a conventional power plant, a wind power plant (WPP) must ensure that the quality of the power being delivered to the grid is excellent. At the same time, the wind turbine should be able to operate immune to small disturbances coming from the grid. Harmonics are one of the more common power quality issues presented by large WPPs because of the high switching frequency of the power converters and the possible nonlinear behavior from electric machines (generator, transformer, reactors) within a power plant. This paper presents a summary of the most important issues related to harmonics in WPPs and discusses practical experiences with actual Type 1 and Type 3 wind turbines in two WPPs.

  12. Demonstration of 5MW PAFC power plant

    Energy Technology Data Exchange (ETDEWEB)

    Usami, Yutaka [Phosphoric Acid Fuel Cell Technology Research Association, Osaka (Japan); Takae, Toshio [New Energy and Industrial Technology Development Organization, Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association, established in May 1991 by Japanese 10 electric power and 4 gas companies, started a new project in 1991 FY, with the object of PAFC realization and aiming the development of 5MW- class PAFC. power plant for urban energy center and 1 MW- class power plant for onsite use. This project is carried out as 6 years plan jointly with New Energy and Industrial Technology Development Organization. The targets of the project are to evaluate and resolve the development task, such as a high reliability, compactness and cost reduction throughout the engineering, manufacturing and field testing of PAFC power plants. PAC tests and power generating test operations of 5MW plant were completed in 1994. Conducting the 2 years continuous operations and studies since 1995, the plant operational performance, system control characteristics, waste heat recovery and environmental advantage will be demonstrated.

  13. Research of the Power Plant Operational Modes

    Directory of Open Access Journals (Sweden)

    Koismynina Nina M.

    2017-01-01

    Full Text Available In this article the algorithm of the power plant operational modes research is offered. According to this algorithm the program for the modes analysis and connection power transformers choice is developed. The program can be used as educational means for studying of the power plant electric part, at the same time basic data are provided. Also the program can be used for the analysis of the working power plants modes. Checks of the entered data completeness and a choice correctness of the operational modes are provided in the program; in all cases of a deviation from the correct decisions to the user the relevant information is given.

  14. Hybrid wind-power-distillation plant

    Directory of Open Access Journals (Sweden)

    Ninić Neven

    2012-01-01

    Full Text Available This paper reports and elaborates on the idea of a solar distiller and an offshore wind power plant operating together. The subject under discussion is a single-stage solar distillation plant with vaporization, using adiabatic expansion in the gravitational field inside a wind power plant supporting column. This scheme divides investment costs for electric power and distillate production. In the region of the Adriatic Sea, all electric power produced could be “converted” to hydrogen using less than 10% of the distillate produced.

  15. Uranium contamination due to nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Martin Sanchez, A.; Vera Tome, F.; Diaz Bejarano, J.; Garcia Aparicio, A. (Univ. de Extremadura, Badajoz (Spain). Dept. de Fisica)

    1992-01-01

    Measurements of uranium isotopes and their daughters in the natural series were performed in the cooling reservoirs and their neighborhood of two nuclear power plants, [alpha] and [gamma] spectrometry of samples were used to measure the natural and artificial radionuclides. The nuclear power plants are in the southwest of Spain and one of them has been in operation since 1982, the other plant is in the construction phase. We compare the results obtained for the two sites. (orig.).

  16. Hydrogen-or-Fossil-Combustion Nuclear Combined-Cycle Systems for Base- and Peak-Load Electricity Production

    Energy Technology Data Exchange (ETDEWEB)

    Forsberg, Charles W [ORNL; Conklin, Jim [ORNL

    2007-09-01

    A combined-cycle power plant is described that uses (1) heat from a high-temperature nuclear reactor to meet base-load electrical demands and (2) heat from the same high-temperature reactor and burning natural gas, jet fuel, or hydrogen to meet peak-load electrical demands. For base-load electricity production, fresh air is compressed; then flows through a heat exchanger, where it is heated to between 700 and 900 C by heat provided by a high-temperature nuclear reactor via an intermediate heat-transport loop; and finally exits through a high-temperature gas turbine to produce electricity. The hot exhaust from the Brayton-cycle gas turbine is then fed to a heat recovery steam generator that provides steam to a steam turbine for added electrical power production. To meet peak electricity demand, the air is first compressed and then heated with the heat from a high-temperature reactor. Natural gas, jet fuel, or hydrogen is then injected into the hot air in a combustion chamber, combusts, and heats the air to 1300 C-the operating conditions for a standard natural-gas-fired combined-cycle plant. The hot gas then flows through a gas turbine and a heat recovery steam generator before being sent to the exhaust stack. The higher temperatures increase the plant efficiency and power output. If hydrogen is used, it can be produced at night using energy from the nuclear reactor and stored until needed. With hydrogen serving as the auxiliary fuel for peak power production, the electricity output to the electric grid can vary from zero (i.e., when hydrogen is being produced) to the maximum peak power while the nuclear reactor operates at constant load. Because nuclear heat raises air temperatures above the auto-ignition temperatures of the various fuels and powers the air compressor, the power output can be varied rapidly (compared with the capabilities of fossil-fired turbines) to meet spinning reserve requirements and stabilize the electric grid. This combined cycle uses the

  17. Thermoeconomic Evaluation of Integrated Solar Combined Cycle Systems (ISCCS

    Directory of Open Access Journals (Sweden)

    Javier Rodríguez Martín

    2014-07-01

    Full Text Available Three alternatives for integrating a solar field with the bottoming cycle of a combined cycle plant are modeled: parabolic troughs with oil at intermediate and low cycle pressures and Fresnel linear collectors at low cycle pressure. It is assumed that the plant will always operate at nominal conditions, using post-combustion during the hours of no solar resource. A thermoeconomic study of the operation of the plant throughout a year has been carried out. The energy and exergy efficiencies of the plant working in fuel only and hybrid modes are compared. The energy efficiencies obtained are very similar; slightly better for the fuel only mode. The exergy efficiencies are slightly better for hybrid operation than for fuel-only mode, due to the high exergy destruction associated with post-combustion. The values for solar electric efficiency are in line with those of similar studies. The economic study shows that the Fresnel hybridization alternative offers similar performance to the others at a significantly lower cost.

  18. Reliability of emergency ac power systems at nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Battle, R E; Campbell, D J

    1983-07-01

    Reliability of emergency onsite ac power systems at nuclear power plants has been questioned within the Nuclear Regulatory Commission (NRC) because of the number of diesel generator failures reported by nuclear plant licensees and the reactor core damage that could result from diesel failure during an emergency. This report contains the results of a reliability analysis of the onsite ac power system, and it uses the results of a separate analysis of offsite power systems to calculate the expected frequency of station blackout. Included is a design and operating experience review. Eighteen plants representative of typical onsite ac power systems and ten generic designs were selected to be modeled by fault trees. Operating experience data were collected from the NRC files and from nuclear plant licensee responses to a questionnaire sent out for this project.

  19. Numerical analysis and field study of time dependent exergy-energy of a gas-steam combined cycle

    Directory of Open Access Journals (Sweden)

    Barari Bamdad

    2012-01-01

    Full Text Available In this study, time dependent exergy analysis of the Fars Combined Power Plant Cycle has been investigated. Exergy analysis has been used for investigating each part of actual combined cycle by considering irreversibility from Apr 2006 to Oct 2010. Performance analysis has been done for each part by evaluating exergy destruction in each month. By using of exergy analysis, aging of each part has been evaluated respect to time duration. In addition, the rate of lost work for each month has been calculated and variation of this parameter has been considered as a function of aging rate. Finally, effects of exergy destruction of each part have been investigated on exergy destruction of whole cycle. Entire analysis has been done for Unit 3 and 4 of gas turbine cycle which combined by Unit B of steam cycle in Fars Combined Power Plant Cycle located in Fars province in Iran.

  20. Gasification integrated to combined cycles; Gasificacion integrada a ciclos combinados

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez M, Manuel F; Alcaraz C, Agustin M [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    The mineral coal is one of the most abundant fuels in the planet, but it has important amounts of sulfur and ashes that make difficult their use. On the other hand, many countries at the present time prevent to use the fuel oil as combustible with conventional technologies due to the metal and sulfur contents. Finally, in the new schemes of oil refinement it is anticipated to use the coking to take advantage of the barrel bottoms. The remainder product of this process, known as refinery coke, has a low commercial value, a high calorific power and high sulfur content and metals. The gasification has been developed in the last the two decades, in the highly industrialized countries, as an alternative for the efficient and clean generation of electricity from dirty fuels, as well as for obtaining certain fuels in places where access to petroleum is not available, but to the coal. This technology fulfills the strictest regulations of the world in what polluting emissions refers and it is the only solution, next to the fluidized beds, for the problems that present some fuels that are difficult to burn with conventional technologies, as the mineral coal, the petroleum coke and even the liquid remainders of the refinement. With base in the former, it is possible to think about the integration of this technology to a combined cycle plant for the generation of electricity or to a refinery generating steam, electrical energy, hydrogen and other consumables at a competitive cost, in such a way that the problems of handling and storage of the remainders are solved; on the other hand the use of the primary power resources in the country is maximized. [Spanish] El carbon mineral es uno de los combustibles mas abundantes en el planeta, pero posee cantidades importantes de azufre y cenizas que dificultan su utilizacion. Por otra parte, muchos paises en la actualidad impiden utilizar el combustoleo como combustible para tecnologias convencionales debido a los contenidos de azufre y

  1. Photovoltaic power plants: production calculation

    Energy Technology Data Exchange (ETDEWEB)

    Cirillo, E.; Lazzarin, R.

    Rational sizing of a photovoltaic plant requires a good evaluation of the obtainable electric energy as a function of the many meteorological and plant parameters. A computing procedure is described in detail together with a fully developed numerical example. The procedure is based on monthly usability. It is reliable and it allows designers to take into account the influence of the main plant parameters within rather wide ranges.

  2. THERMODYNAMIC ANALYSIS OF CARBON SEQUESTRATION METHODS IN LIGNITE POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Koroneos J. Christopher; Sakiltzis Christos; Rovas C. Dimitrios [Laboratory of Heat Transfer and Environmental Engineering, Department of Mechanical Engineering, Aristotle University of Thessaloniki, Thessaloniki (Greece)

    2008-09-30

    The green house effect is a very pressing issue of our times due to the big impact it will have in the future of life in our planet. The temperature increase of the earth which is the major impact of the greenhouse effect may change forever the climate and the way of life in many countries. It may lead to the reduction of agricultural production and at the end to famine, in several nations. The minimization of CO2 emissions and the introduction of new energy sources is the only solution to the catastrophe that is coming if inaction prevails. The objective of this work is to analyze the methods of the CO2 removal from the flue gases of power plants that use solid fuels. It is especially fit to the Greek conditions where the main fuel used is lignite. Three methods have been examined and compared thermodynamically. These are: (a) Removal of CO2 from the flue gas stream by absorption, (b) The combustion of lignite with pure oxygen and (c) The gasification of lignite. The lignite used in the analysis is the Greek lignite, produced at the Western Macedonia mines. The power plant, before carbon sequestration, has an efficiency of 39%, producing 330MW of electric power. After sequestration, the CO2 is compressed to pressures between 80-110 atm, before its final disposal. In the first method, the sequestration of CO2 is done utilizing a catalyst. The operation requires electricity and high thermal load which is received from low pressure steam extracted from the turbines. Additionally, electricity is required for the compression of the CO2 to 100 bars. This leads to a lower efficiency of the power plant by by 13%. In the second method, the lignite combustion is done with pure O2 produced at an air separation unit. The flue gasses are made up of CO2 and water vapor. This method requires electricity for carbon dioxide compression and the Air Separation unit, thus, the power plant efficiency is lowered by 26%. In the lignite gasification method, the products are a mixture of

  3. Development and application of performance and cost models for the externally-fired combined cycle. Task 1, Volume 2. Topical report, June 1995

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, P.; Frey, H. [North Carolina State Univ., Raleigh, NC (United States); Rubin, E.S. [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    1995-07-01

    Increasing restrictions on emission of pollutants from conventional pulverized coal fired steam (PCFS) plant generating electrical power is raising capital and operating cost of these plants and at the same time lowering plant efficiency. This is creating a need for alternative technologies which result in lower emissions of regulated pollutants and which are thermally more efficient. Natural gas-fired combined cycle power generation systems have lower capital cost and higher efficiencies than conventional coal fired steam plants, and at this time they are the leading contender for new power plant construction in the U.S. But the intermediate and long term cost of these fuels is high and there is uncertainty regarding their long-term price and availability. Coal is a relatively low cost fuel which will be abundantly available in the long term. This has motivated the development of advanced technologies for power production from coal which will have advantages of other fuels. The Externally Fired Combined Cycle (EFCC) is one such technology. Air pollution control/hot gas cleanup issues associated with this technology are described.

  4. The potential for adding plastic waste fuel at a coal gasification power plant.

    Science.gov (United States)

    Campbell, P E; Evans, R H; McMullan, J T; Williams, B C

    2001-12-01

    Plastics wastes from a municipal solid waste plant have a high energy content which make it an interesting option for co-processing with coal. The potential for adding plastic waste to a coal fired Texaco IGCC (Integrated Gasification Combined Cycle) power station is examined. The resulting efficiency increases due to the improved gasification qualities of plastic over coal. For the overall economics to be the same as the coal only case, the maximum amount that the power station can afford to spend on preparing the plastic waste for use is similar to the assumed coal cost, plus the avoided landfill cost, minus the transport cost. The location of the power station plays a key role, since this has an effect on the transport costs as well as on the landfill charges. The sensitivity of the economics of co-processing plastic waste with coal for a variety of power station operational parameters is presented.

  5. Comparison of advanced engines for parabolic dish solar thermal power plants

    Science.gov (United States)

    Fujita, T.; Bowyer, J. M.; Gajanana, B. C.

    1980-01-01

    A paraboloidal dish solar thermal power plant produces electrical energy by a two-step conversion process. The collector subsystem is composed of a two-axis tracking paraboloidal concentrator and a cavity receiver. The concentrator focuses intercepted sunlight (direct, normal insolation) into a cavity receiver whose aperture encircles the focal point of the concentrator. At the internal wall of the receiver the electromagnetic radiation is converted to thermal energy. A heat engine/generator assembly then converts the thermal energy captured by the receiver to electricity. Developmental activity has been concentrated on small power modules which employ 11- to 12-meter diameter dishes to generate nominal power levels of approximately 20 kWe. A comparison of advanced heat engines for the dish power module is presented in terms of the performance potential of each engine with its requirements for advanced technology development. Three advanced engine possibilities are the Brayton (gas turbine), Brayton/Rankine combined cycle, and Stirling engines.

  6. Direct flash steam geothermal power plant assessment

    Science.gov (United States)

    Alt, T. E.

    1982-01-01

    The objective was to analyze the capacity and availability factors of an operating direct flash geothermal power plant. System and component specifications, operating procedures, maintenance history, malfunctions, and outage rate are discussed. The plant studied was the 75 MW(e) geothermal power plant at Cerro Prieto, Mexico, for the years 1973 to 1979. To describe and assess the plant, the project staff reviewed documents, visited the plant, and met with staff of the operating utility. The high reliability and availability of the plant was documented and actions responsible for the good performance were identified and reported. The results are useful as guidance to US utilities considering use of hot water geothermal resources for power generation through a direct flash conversion cycle.

  7. Joint excitation and reactive power control in thermal power plant

    Directory of Open Access Journals (Sweden)

    Dragosavac Jasna

    2013-01-01

    Full Text Available The coordinated voltage and reactive power controller, designed for the thermal power plant, is presented in the paper. A brief explanation of the need for such device is given and justification for commissioning of such equipment is outlined. After short description of the theoretical background of the proposed control design, the achieved features of the commissioned equipment are fully given. Achieved performances are illustrated by recorded reactive power and bus voltage responses after commissioning of the described equipment into the largest thermal power plant in Serbia. As it can be seen in presented records, all design targets are met.

  8. Hybrid Combined Cycles with Biomass and Waste Fired Bottoming Cycle - a Literature Study

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Miroslav P.

    2002-02-01

    Biomass is one of the main natural resources in Sweden. The present low-CO{sub 2} emission characteristics of the Swedish electricity production system (hydro and nuclear) can be retained only by expansion of biofuel applications for energy purposes. Domestic Swedish biomass resources are vast and renewable, but not infinite. They must be utilized as efficiently as possible, in order to make sure that they meet the conditions for sustainability in the future. Application of efficient power generation cycles at low costs is essential for meeting this challenge. This applies also to municipal solid waste incineration with energy extraction, which should be preferred to its dumping in landfills. Hybrid dual-fuel combined cycle units are a simple and affordable way to increase the electric efficiency of biofuel energy utilization, without big investments, uncertainties or loss of reliability arising from complicated technologies. Configurations of such power cycles are very flexible and reliable. Their potential for high electric efficiency in condensing mode, high total efficiency in combined heat and power mode and unrivalled load flexibility is explored in this project. The present report is a literature study that concentrates on certain biomass utilization technologies, in particular the design and performance of hybrid combined cycle power units of various configurations, with gas turbines and internal combustion engines as topping cycles. An overview of published literature and general development trends on the relevant topic is presented. The study is extended to encompass a short overview of biomass utilization as an energy source (focusing on Sweden), history of combined cycles development with reference especially to combined cycles with supplementary firing and coal-fired hybrid combined cycles, repowering of old steam units into hybrid ones and combined cycles for internal combustion engines. The hybrid combined cycle concept for municipal solid waste

  9. Solar-Augment Potential of U.S. Fossil-Fired Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Turchi, C.; Langle, N.; Bedilion, R.; Libby, C.

    2011-02-01

    Concentrating Solar Power (CSP) systems utilize solar thermal energy for the generation of electric power. This attribute makes it relatively easy to integrate CSP systems with fossil-fired power plants. The 'solar-augment' of fossil power plants offers a lower cost and lower risk alternative to stand-alone solar plant construction. This study ranked the potential to add solar thermal energy to coal-fired and natural gas combined cycle (NGCC) plants found throughout 16 states in the southeast and southwest United States. Each generating unit was ranked in six categories to create an overall score ranging from Excellent to Not Considered. Separate analysis was performed for parabolic trough and power tower technologies due to the difference in the steam temperatures that each can generate. The study found a potential for over 11 GWe of parabolic trough and over 21 GWe of power tower capacity. Power towers offer more capacity and higher quality integration due to the greater steam temperatures that can be achieved. The best sites were in the sunny southwest, but all states had at least one site that ranked Good for augmentation.

  10. Robust control of speed and temperature in a power plant gas turbine.

    Science.gov (United States)

    Najimi, Ebrahim; Ramezani, Mohammad Hossein

    2012-03-01

    In this paper, an H(∞) robust controller has been designed for an identified model of MONTAZER GHAEM power plant gas turbine (GE9001E). In design phase, a linear model (ARX model) which is obtained using real data has been applied. Since the turbine has been used in a combined cycle power plant, its speed and also the exhaust gas temperature should be adjusted simultaneously by controlling fuel signals and compressor inlet guide vane (IGV) position. Considering the limitations on the system inputs, the aim of the control is to maintain the turbine speed and the exhaust gas temperature within desired interval under uncertainties and load demand disturbances. Simulation results of applying the proposed robust controller on the nonlinear model of the system (NARX model), fairly fulfilled the predefined aims. Simulations also show the improvement in the performance compared to MPC and PID controllers for the same conditions.

  11. Survey of modern power plants driven by diesel and gas engines

    Energy Technology Data Exchange (ETDEWEB)

    Niemi, S. [Turku Polytechnic, Turku (Finland)

    1997-12-31

    This report surveys the latest technology of power plants driven by reciprocating internal combustion (IC) engines, from information collected from publications made mainly during the 1990`s. Diesel and gas engines are considered competitive prime movers in power production due mainly to their high full- and part-load brake thermal efficiency, ability to burn different fuels, short construction time and fast start-ups. The market for engine power plants has grown rapidly, with estimated total orders for reciprocating engines of 1 MW output and more reaching the 5000 unit level, (10 GW), between June 1995 and May 1996. Industrialized countries much prefer combined heat and power (CHP) production. Intense interest has been shown in recent years in alternative gas fuels; natural gas appears to be the most promising, but liquid petroleum gas, gas from sewage disposal plants, landfill gas and other biogases, as well as wood gas have also been recognized as other alternatives. Liquid alternatives such as fuels and pyrolysis oil have also been mentioned, in addition to information on coal burning engines. The percentage of gas engines used has increased and different ones are being developed, based on either the traditional spark ignition (SI), dual-fuel technology or the more recent high pressure gas injection system. In cold climates, energy production is largely based on CHP plants. Waste heat is utilized for local, regional or district heating or for industrial uses like drying, heating, cooling etc. Even radiative and convective heat from gen-set surfaces are employed, and boilers are used with exhaust outlet temperatures of below dew point. Combined cycle schemes, including turbo compound systems and steam turbines, are also incorporated into engine power plants in order to increase output and efficiency. Two-stroke, low-speed diesel engine plants show the highest electric efficiencies, with combined cycle plants reaching up to 54 %, while gas engine plants achieved

  12. EPA Facility Registry Service (FRS): Power Plants

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains data on power plants, based on the Energy Information Administration's EIA-860 dataset and supplemented with data from EPA's Facility...

  13. Current fusion power plant design concepts

    Energy Technology Data Exchange (ETDEWEB)

    Gore, B.F.; Murphy, E.S.

    1976-09-01

    Nine current U.S. designs for fusion power plants are described in this document. Summary tabulations include a tenth concept, for which the design document was unavailable during preparation of the descriptions. The information contained in the descriptions was used to define an envelope of fusion power plant characteristics which formed the basis for definition of reference first commercial fusion power plant design. A brief prose summary of primary plant features introduces each of the descriptions contained in the body of this document. In addition, summary tables are presented. These tables summarize in side-by-side fashion, plant parameters, processes, combinations of materials used, requirements for construction materials, requirements for replacement materials during operation, and production of wastes.

  14. 76 FR 1469 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2011-01-10

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2... Cliffs Nuclear Power Plant, LLC, the licensee, for operation of the Calvert Cliffs Nuclear Power Plant..., Calvert Cliffs Nuclear Power Plant (NUREG-1437, Supplement 1), dated......

  15. Assessment of nuclear power plant siting methods

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.D.; Hobbs, B.F.; Pierce, B.L.; Meier, P.M.

    1979-11-01

    Several different methods have been developed for selecting sites for nuclear power plants. This report summarizes the basic assumptions and formal requirements of each method and evaluates conditions under which each is correctly applied to power plant siting problems. It also describes conditions under which different siting methods can produce different results. Included are criteria for evaluating the skill with which site-selection methods have been applied.

  16. Topologies for large scale photovoltaic power plants

    OpenAIRE

    Cabrera Tobar, Ana; Bullich Massagué, Eduard; Aragüés Peñalba, Mònica; Gomis Bellmunt, Oriol

    2016-01-01

    © 2016 Elsevier Ltd. All rights reserved. The concern of increasing renewable energy penetration into the grid together with the reduction of prices of photovoltaic solar panels during the last decade have enabled the development of large scale solar power plants connected to the medium and high voltage grid. Photovoltaic generation components, the internal layout and the ac collection grid are being investigated for ensuring the best design, operation and control of these power plants. This ...

  17. Parametric Investigation and Thermoeconomic Optimization of a Combined Cycle for Recovering the Waste Heat from Nuclear Closed Brayton Cycle

    Directory of Open Access Journals (Sweden)

    Lihuang Luo

    2016-01-01

    Full Text Available A combined cycle that combines AWM cycle with a nuclear closed Brayton cycle is proposed to recover the waste heat rejected from the precooler of a nuclear closed Brayton cycle in this paper. The detailed thermodynamic and economic analyses are carried out for the combined cycle. The effects of several important parameters, such as the absorber pressure, the turbine inlet pressure, the turbine inlet temperature, the ammonia mass fraction, and the ambient temperature, are investigated. The combined cycle performance is also optimized based on a multiobjective function. Compared with the closed Brayton cycle, the optimized power output and overall efficiency of the combined cycle are higher by 2.41% and 2.43%, respectively. The optimized LEC of the combined cycle is 0.73% lower than that of the closed Brayton cycle.

  18. Performance Comparison on Repowering of a Steam Power Plant with Gas Turbines and Solid Oxide Fuel Cells

    DEFF Research Database (Denmark)

    Rokni, Masoud

    2016-01-01

    Repowering is a process for transforming an old power plant for greater capacity and/or higher efficiency. As a consequence, the repowered plant is characterized by higher power output and less specific CO2 emissions. Usually, repowering is performed by adding one or more gas turbines...... of this study, repowering of an existing power plant with SOFC as well as gas turbines. Different repowering strategies are studied here, repowering with one gas turbine with and without supplementary firing, repowering with two gas turbines with and without supplementary firing and finally repowering using...... into an existing steam cycle which was built decades ago. Thus, traditional repowering results in combined cycles (CC). High temperature fuel cells (such as solid oxide fuel cell (SOFC)) could also be used as a topping cycle, achieving even higher global plant efficiency and even lower specific CO2 emissions...

  19. Efficiencies of Power Plants Using Hydrothermal Oxidation

    Science.gov (United States)

    Hirosaka, Kazuma; Yuvamitra, Korakot; Ishikawa, Akira; Hasegawa, Tatsuya

    Wet biomass is hard to handle as a fuel for power plants because it contains high moisture and its drying process needs more energy input than it produces. Hydrothermal oxidation could be one of the promising technologies to overcome this problem because this process does not need drying process at all. We focus on recovery of thermal energy produced by hydrothermal oxidation of wet biomass. Two kinds of power plant are investigated, a direct type and an indirect type. In the direct type power plant, reactant is oxidized in a reactor and directly flowed into a turbine. In the indirect type power plant, reactant is oxidized in a reactor and the reaction heat is conveyed to the main water, which is flowed into a turbine. The amount of electric power and the energy conversion efficiency are calculated by using ethanol, glucose and peat solutions as reactants. In both type of power plant, one steam turbine is employed for generating electricity with the maximum turbine inlet temperature of 650 °C. As ethanol concentration increased, the amount of electric power and the energy conversion efficiency become higher. The maximum efficiency for the direct type power plant using ethanol solution is about 26.4 % for 17.6 wt% at the reactor pressure of 10 MPa. The efficiency of the indirect type power plant is much lower than that of the direct type, but by pressurizing main water up to 4 MPa, the efficiency becomes higher up to 20.9 %. For glucose solution, the maximum efficiency for the direct type is about 25.5 % for 34.5 wt% at the reactor pressure of 5 MPa. The maximum efficiency of the indirect type at the main water pressure of 4 MPa is about 21.1 % for 40.7 wt%. For peat solution, only the indirect type is investigated. The maximum efficiency at the main water pressure of 4 MPa is about 20.8 % for 36.8 wt%.

  20. Simulation of hybrid solar power plants

    Science.gov (United States)

    Dieckmann, Simon; Dersch, Jürgen

    2017-06-01

    Hybrid solar power plants have the potential to combine advantages of two different technologies at the cost of increased complexity. The present paper shows the potential of the software greenius for the techno-economic evaluation of hybrid solar power plants and discusses two exemplary scenarios. Depreciated Concentrated Solar Power (CSP) plants based on trough technology can be retrofitted with solar towers in order to reach higher steam cycle temperatures and hence efficiencies. Compared to a newly built tower plant the hybridization of a depreciated trough plant causes about 30% lower LCOE reaching 104 /MWh. The second hybrid scenario combines cost-efficient photovoltaics with dispatchable CSP technology. This hybrid plant offers very high capacity factors up to 69% based on 100% load from 8am to 11pm. The LCOE of the hybrid plant are only slightly lower (174 vs. 186 /MWh) compared to the pure CSP plant because the capital expenditure for thermal storage and power block remains the same while the electricity output is much lower.

  1. OUT Success Stories: Solar Trough Power Plants

    Science.gov (United States)

    Jones, J.

    2000-08-01

    The Solar Electric Generating System (SEGS) plants use parabolic-trough solar collectors to capture the sun's energy and convert it to heat. The SEGS plants range in capacity from 13.8 to 80 MW, and they were constructed to meet Southern California Edison Company's periods of peak power demand.

  2. Transient Simulation Of A Solar-Hybrid Tower Power Plant With Open Volumetric Receiver At The Location Barstow

    OpenAIRE

    2013-01-01

    In this work the transient simulations of four hybrid solar tower power plant concepts with open-volumetric receiver technology for a location in Barstow-Daggett, USA, are presented. The open-volumetric receiver uses ambient air as heat transfer fluid and the hybridization is realized with a gas turbine. The Rankine cycle is heated by solar-heated air and/or by the gas turbine’s flue gases. The plant can be operated in solar-only, hybrid parallel or combined cycle-only mode as well a...

  3. Variable geometry gas turbines for improving the part-load performance of marine combined cycles - Combined cycle performance

    DEFF Research Database (Denmark)

    Haglind, Fredrik

    2011-01-01

    -derivative configuration and a single-shaft industrial configuration. The results suggest that by the use of variable geometry gas turbines, the combined cycle part-load performance can be improved. In order to minimise the voyage fuel consumption, a combined cycle featuring two-shaft gas turbines with VAN control...

  4. Questions and Answers About Nuclear Power Plants.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC.

    This pamphlet is designed to answer many of the questions that have arisen about nuclear power plants and the environment. It is organized into a question and answer format, with the questions taken from those most often asked by the public. Topics include regulation of nuclear power sources, potential dangers to people's health, whether nuclear…

  5. Informatization of Power Plant and Its Implementation

    Institute of Scientific and Technical Information of China (English)

    Zhang Zhenghai

    2006-01-01

    @@ This paper presents the working procedure of power generating enterprises and explains the framework of an e-power-plant and its information system, puts forward the guideline and the general goal of informatization construction while focusing on the construction goal in the applied system, the implementing strategy, the project management and organization.

  6. The History and Promise of Combined Cycle Engines for Access to Space Applications

    Science.gov (United States)

    Clark, Casie

    2010-01-01

    For the summer of 2010, I have been working in the Aerodynamics and Propulsion Branch at NASA Dryden Flight Research Center studying combined-cycle engines, a high speed propulsion concept. Combined cycle engines integrate multiple propulsion systems into a single engine capable of running in multiple modes. These different modes allow the engine to be extremely versatile and efficient in varied flight conditions. The two most common types of combined cycle engines are Rocket-Based Combined Cycle (RBCC) and Turbine Based Combined Cycle (TBCC). The RBCC essentially combines a rocket and ramjet engine, while the TBCC integrates a turbojet and ramjet1. These two engines are able to switch between different propulsion modes to achieve maximum performance. Extensive conceptual and ground test studies of RBCC engines have been undertaken; however, an RBCC engine has never, to my knowledge, been demonstrated in flight. RBCC engines are of particular interest because they could potentially power a reusable launch vehicle (RLV) into space. The TBCC has been flight tested and shown to be effective at reaching supersonic speeds, most notably in the SR-71 Blackbird2.

  7. Technical evaluation of biomass gasification technology integrated with combined cycle using bagasse as fuel; Avaliacao tecnica da tecnologia de gaseificacao de biomassa integrada a ciclos combinados utilizando bagaco como combustivel

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, Pablo Silva; Venturini, Osvaldo Jose; Lora, Electo Silva [Universidade Federal de Itajuba (NEST/UNIFEI), MG (Brazil). Nucleo de Excelencia em Geracao Termeletrica e Distribuida], email: pablo.silvaortiz@gmail.com; Campo, Andres Perez [Universidade Automona de Bucaramanga (UNAB) (Colombia). Fac. de Engenharia Fisico- Mecanica, Engenharia em Energia

    2010-07-01

    Biomass Integrated Gasification Combined Cycle (BIGCC) was identified as an advanced technology with potential to be competitive for electricity generation. The BIGCC technology uses biomass and the sub products of some industrial sectors processing, like sugar cane, as feedstock. The current Brazilian energy matrix is mainly based on renewable generation sources, making it important to assess these gasification technologies in the production of sugar, ethanol and electricity. In this work, a technical evaluation of the technologies incorporated in BIGCC power plants is done: the gasification process and the combined cycle power plant. On the other hand, the generated costs of these systems are analyzed, and the potential for implementation in Brazil plants from sugar cane bagasse is studied, in which a 10% increase in efficiency is obtained. (author)

  8. Process modelling and techno-economic analysis of natural gas combined cycle integrated with calcium looping

    Directory of Open Access Journals (Sweden)

    Erans María

    2016-01-01

    Full Text Available Calcium looping (CaL is promising for large-scale CO2 capture in the power generation and industrial sectors due to the cheap sorbent used and the relatively low energy penalties achieved with this process. Because of the high operating temperatures the heat utilisation is a major advantage of the process, since a significant amount of power can be generated from it. However, this increases its complexity and capital costs. Therefore, not only the energy efficiency performance is important for these cycles, but also the capital costs must be taken into account, i.e. techno-economic analyses are required in order to determine which parameters and configurations are optimal to enhance technology viability in different integration scenarios. In this study the integration scenarios of CaL cycles and natural gas combined cycles (NGCC are explored. The process models of the NGCC and CaL capture plant are developed to explore the most promising scenarios for NGCC-CaL integration with regards to efficiency penalties. Two scenarios are analysed in detail, and show that the system with heat recovery steam generator (HRSG before and after the capture plant exhibited better performance of 49.1% efficiency compared with that of 45.7% when only one HRSG is located after the capture plant. However, the techno-economic analyses showed that the more energy efficient case, with two HRSGs, implies relatively higher cost of electricity (COE, 44.1€/MWh, when compared to that of the reference plant system (33.1€/MWh. The predicted cost of CO2 avoided for the case with two HRSGS is 29.3 €/ton CO2.

  9. Safety Assessment - Swedish Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kjellstroem, B. [Luleaa Univ. of Technology (Sweden)

    1996-12-31

    After the reactor accident at Three Mile Island, the Swedish nuclear power plants were equipped with filtered venting of the containment. Several types of accidents can be identified where the filtered venting has no effect on the radioactive release. The probability for such accidents is hopefully very small. It is not possible however to estimate the probability accurately. Experiences gained in the last years, which have been documented in official reports from the Nuclear Power Inspectorate indicate that the probability for core melt accidents in Swedish reactors can be significantly larger than estimated earlier. A probability up to one in a thousand operating years can not be excluded. There are so far no indications that aging of the plants has contributed to an increased accident risk. Maintaining the safety level with aging nuclear power plants can however be expected to be increasingly difficult. It is concluded that the 12 Swedish plants remain a major threat for severe radioactive pollution of the Swedish environment despite measures taken since 1980 to improve their safety. Closing of the nuclear power plants is the only possibility to eliminate this threat. It is recommended that until this is done, quantitative safety goals, same for all Swedish plants, shall be defined and strictly enforced. It is also recommended that utilities distributing misleading information about nuclear power risks shall have their operating license withdrawn. 37 refs.

  10. Advanced coal-fired power plant technology

    Energy Technology Data Exchange (ETDEWEB)

    Klauke, F. [Babcock Borsig Power Energy GmbH (Germany)

    2001-07-01

    This paper presents the joint efforts of a large European group of manufacturers, utilities and institutes co-operating in a phased long-term project named 'Advanced 700{degree}C PF Power Plant'. Net efficiences of more than 50% will be reached through development of a super critical steam cycle operating at maximum steam temperatures in the range of 700{degree}C. The principal efforts are based on development of creep resistent nickel-based materials named super-alloys for the hottest areas of the water/steam cycle. The Advanced 700{degree}C PF Power Plant project will improve the competitiveness of coal-fired power generation. Furthermore, it will provide a major reduction of CO{sub 2} from coal-fired power plants in the range of 15% from the best PF power plants presently and up to 40% from older plants. The demonstration programme will leave the possibility of any plant output between 400 and 1000 MW. The project will run to the end of 2003. 8 figs.

  11. Perspectives on Magnetized Target Fusion Power Plants

    Science.gov (United States)

    Miller, R. L.

    2007-06-01

    One approach to Magnetized Target Fusion (MTF) builds upon the ongoing experimental effort (FRX-L) to generate a Field Reversed Configuration (FRC) target plasma suitable for translation and cylindrical-liner (i.e., converging flux conserver) implosion. Numerical modeling is underway to elucidate key performance drivers for possible future power-plant extrapolations. The fusion gain, Q (ratio of DT fusion yield to the sum of initial liner kinetic energy plus plasma formation energy), sets the power-plant duty cycle for a nominal design electric power [ e.g. 1,000 MWe(net)]. A pulsed MTF power plant of this type derives from the historic Fast Liner Reactor (FLR) concept and shares attributes with the recent Inertial Fusion Energy (IFE) Z-pinch and laser-driven pellet HYLIFE-II conceptual designs.

  12. Integration of torrefaction with steam power plant

    Energy Technology Data Exchange (ETDEWEB)

    Zakri, B.; Saari, J.; Sermyagina, E.; Vakkilainen, E.

    2013-09-01

    Torrefaction is one of the pretreatment technologies to enhance the fuel characteristics of biomass. The efficient and continuous operation of a torrefaction reactor, in the commercial scale, demands a secure biomass supply, in addition to adequate source of heat. Biorefinery plants or biomass-fuelled steam power plants have the potential to integrate with the torrefaction reactor to exchange heat and mass, using available infrastructure and energy sources. The technical feasibility of this integration is examined in this study. A new model for the torrefaction process is introduced and verified by the available experimental data. The torrefaction model is then integrated in different steam power plants to simulate possible mass and energy exchange between the reactor and the plants. The performance of the integrated plant is investigated for different configurations and the results are compared. (orig.)

  13. Monitoring Biological Activity at Geothermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Peter Pryfogle

    2005-09-01

    The economic impact of microbial growth in geothermal power plants has been estimated to be as high as $500,000 annually for a 100 MWe plant. Many methods are available to monitor biological activity at these facilities; however, very few plants have any on-line monitoring program in place. Metal coupon, selective culturing (MPN), total organic carbon (TOC), adenosine triphosphate (ATP), respirometry, phospholipid fatty acid (PLFA), and denaturing gradient gel electrophoresis (DGGE) characterizations have been conducted using water samples collected from geothermal plants located in California and Utah. In addition, the on-line performance of a commercial electrochemical monitor, the BIoGEORGE?, has been evaluated during extended deployments at geothermal facilities. This report provides a review of these techniques, presents data on their application from laboratory and field studies, and discusses their value in characterizing and monitoring biological activities at geothermal power plants.

  14. The positioning of Iberdrola Ingenieria y Construccion in the market for new electric power plants; Posicionamiento de Iberdrola Ingenieria y Construccion en el mercado de las nuevas centrales

    Energy Technology Data Exchange (ETDEWEB)

    Garnica, E.; Cubain, B.; Chimeno, M. A.; Ortego, A.

    2009-07-01

    IBERDROLA Ingeneria y Contruccion carrying out a wide plant of activities oriented to position the company in the emerging marketplace of new nuclear power plants whose expectation for the next years is highly promising. Obviously, the plan is focused in their technicians, which include people that are very knowledgeable and others younger, both strongly committed with the managerial project. During the las years, the gained experience in nuclear projects, together with other successfully generation projects (combined cycles gas turbine and renewable) allow warranty the success in the challenge of building new nuclear power plants for the next years. (Author)

  15. Nuclear power plant security assessment technical manual.

    Energy Technology Data Exchange (ETDEWEB)

    O' Connor, Sharon L.; Whitehead, Donnie Wayne; Potter, Claude S., III

    2007-09-01

    This report (Nuclear Power Plant Security Assessment Technical Manual) is a revision to NUREG/CR-1345 (Nuclear Power Plant Design Concepts for Sabotage Protection) that was published in January 1981. It provides conceptual and specific technical guidance for U.S. Nuclear Regulatory Commission nuclear power plant design certification and combined operating license applicants as they: (1) develop the layout of a facility (i.e., how buildings are arranged on the site property and how they are arranged internally) to enhance protection against sabotage and facilitate the use of physical security features; (2) design the physical protection system to be used at the facility; and (3) analyze the effectiveness of the PPS against the design basis threat. It should be used as a technical manual in conjunction with the 'Nuclear Power Plant Security Assessment Format and Content Guide'. The opportunity to optimize physical protection in the design of a nuclear power plant is obtained when an applicant utilizes both documents when performing a security assessment. This document provides a set of best practices that incorporates knowledge gained from more than 30 years of physical protection system design and evaluation activities at Sandia National Laboratories and insights derived from U.S. Nuclear Regulatory Commission technical staff into a manual that describes a development and analysis process of physical protection systems suitable for future nuclear power plants. In addition, selected security system technologies that may be used in a physical protection system are discussed. The scope of this document is limited to the identification of a set of best practices associated with the design and evaluation of physical security at future nuclear power plants in general. As such, it does not provide specific recommendations for the design and evaluation of physical security for any specific reactor design. These best practices should be applicable to the design and

  16. Nuclear Security for Floating Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Skiba, James M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Scherer, Carolynn P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-13

    Recently there has been a lot of interest in small modular reactors. A specific type of these small modular reactors (SMR,) are marine based power plants called floating nuclear power plants (FNPP). These FNPPs are typically built by countries with extensive knowledge of nuclear energy, such as Russia, France, China and the US. These FNPPs are built in one country and then sent to countries in need of power and/or seawater desalination. Fifteen countries have expressed interest in acquiring such power stations. Some designs for such power stations are briefly summarized. Several different avenues for cooperation in FNPP technology are proposed, including IAEA nuclear security (i.e. safeguards), multilateral or bilateral agreements, and working with Russian design that incorporates nuclear safeguards for IAEA inspections in non-nuclear weapons states

  17. Fresnel-collectors in hybrid solar thermal power plants with high solar shares

    Energy Technology Data Exchange (ETDEWEB)

    Lerchenmueller, H.; Mertins, M.; Morin, G. [Fraunhofer Inst. for Solar Energy Systems, Freiburg (Germany); Haeberle, A. [PSE GmbH, Solar Info Center, Freiburg (Germany); Bockamp, S.; Ewert, M.; Fruth, M.; Griestop, T. [E.ON Energie AG, Muenchen (Germany); Dersch, J. [Deutsches Zentrum fuer Luft- und Raumfahrt, Koeln (Germany)

    2004-07-01

    The use of Fresnel-Collectors in power plant configurations with low or zero CO2-emission has been analysed in this paper. Both, the solar-biomass hybrid plant and the solar-gas hybrid plant are very promising concepts with respect to technical, economical and ecological aspects. The hybrid operation would be very useful to handle the fluctuating solar resource and facilitate operation. Depending on feed in tariffs the hybridisation of a solar thermal power plant with biomass or with small shares of natural gas can be economically very interesting. The ecological advantage of a solar-biomass power plant is evident, since it would be a zero CO2- emission plant. Beyond that biomass is a limited source, especially in regions with high solar irradiance. The herein examined gas hybrid variants are by far more favourable than Integrated Solar Combined Cycle Systems (ISCCS), which have been previously examined. Since much higher solar shares can be reached this is a forward-looking technology. Furthermore the solar field does not act as a disturbing factor as opposed to the ISCCS concept, where the efficiency of the sophisticated CC system is reduced due to suboptimal dimensioning of components. In other words: It is better to build the suggested hybrid plant with low gas share and CC plants instead of ISCCS plants. The resulting solar levelised electricity costs of both options are approximately the same. The calculated levelised electricity costs for the examined configurations of between 11 and 13 ct/kWh are very promising results. The calculations were made based on cost assumptions for the collector of 130 Euro/m{sup 2} which seems realistic not for the first project but for the third plant. As a next step in the commercialisation of the Fresnel-technology demonstration and test collectors must be built, such as by the Australian company Solar Heat and Power, to validate the technical and economic assumptions. (orig.)

  18. Wabash Valley Integrated Gasification Combined Cycle, Coal to Fischer Tropsch Jet Fuel Conversion Study

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Jayesh [Lummus Technology Inc., Bloomfield, NJ (United States); Hess, Fernando [Lummus Technology Inc., Bloomfield, NJ (United States); Horzen, Wessel van [Lummus Technology Inc., Bloomfield, NJ (United States); Williams, Daniel [Lummus Technology Inc., Bloomfield, NJ (United States); Peevor, Andy [JM Davy, London (United Kingdom); Dyer, Andy [JM Davy, London (United Kingdom); Frankel, Louis [Canonsburgh, PA (United States)

    2016-06-01

    This reports examines the feasibility of converting the existing Wabash Integrated Gasification Combined Cycle (IGCC) plant into a liquid fuel facility, with the goal of maximizing jet fuel production. The fuels produced are required to be in compliance with Section 526 of the Energy Independence and Security Act of 2007 (EISA 2007 §526) lifecycle greenhouse gas (GHG) emissions requirements, so lifecycle GHG emissions from the fuel must be equal to or better than conventional fuels. Retrofitting an existing gasification facility reduces the technical risk and capital costs associated with a coal to liquids project, leading to a higher probability of implementation and more competitive liquid fuel prices. The existing combustion turbine will continue to operate on low cost natural gas and low carbon fuel gas from the gasification facility. The gasification technology utilized at Wabash is the E-Gas™ Technology and has been in commercial operation since 1995. In order to minimize capital costs, the study maximizes reuse of existing equipment with minimal modifications. Plant data and process models were used to develop process data for downstream units. Process modeling was utilized for the syngas conditioning, acid gas removal, CO2 compression and utility units. Syngas conversion to Fischer Tropsch (FT) liquids and upgrading of the liquids was modeled and designed by Johnson Matthey Davy Technologies (JM Davy). In order to maintain the GHG emission profile below that of conventional fuels, the CO2 from the process must be captured and exported for sequestration or enhanced oil recovery. In addition the power utilized for the plant’s auxiliary loads had to be supplied by a low carbon fuel source. Since the process produces a fuel gas with sufficient energy content to power the plant’s loads, this fuel gas was converted to hydrogen and exported to the existing gas turbine for low carbon power production. Utilizing low carbon fuel gas and

  19. Technical efficiency of thermoelectric power plants

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Carlos Pestana [Instituto de Economia e Gestao, Technical University of Lisbon, Rua Miguel Lupi, 20, 1249-078 Lisbon (Portugal); Peypoch, Nicolas [GEREM, LAMPS, IAE, Universite de Perpignan Via Domitia, 52 avenue Paul Alduy, F-66860 Perpignan (France)

    2008-11-15

    This paper analyses the technical efficiency of Portuguese thermoelectric power generating plants with a two-stage procedure. In the first stage, the plants' relative technical efficiency is estimated with DEA (data envelopment analysis) to establish which plants perform most efficiently. These plants could serve as peers to help improve performance of the least efficient plants. The paper ranks these plants according to their relative efficiency for the period 1996-2004. In a second stage, the Simar and Wilson [Simar, L., Wilson, P.W., 2007. Estimation and inference in two-stage, semi-parametric models of production processes. Journal of Econometrics 136, 1-34] bootstrapped procedure is adopted to estimate the efficiency drivers. Economic implications arising from the study are considered. (author)

  20. Efficiency improvement of thermal coal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hourfar, D. [VEBA Kraftwerke Ruhr Ag, Gelsenkirchen (Germany)

    1996-12-31

    The discussion concerning an increase of the natural greenhouse effect by anthropogenic changes in the composition of the atmosphere has increased over the past years. The greenhouse effect has become an issue of worldwide debate. Carbon dioxide is the most serious emission of the greenhouse gases. Fossil-fired power plants have in the recent past been responsible for almost 30 % of the total CO{sub 2} emissions in Germany. Against this background the paper will describe the present development of CO{sub 2} emissions from power stations and present actual and future opportunities for CO{sub 2} reduction. The significance attached to hard coal as one of today`s prime sources of energy with the largest reserves worldwide, and, consequently, its importance for use in power generation, is certain to increase in the years to come. The further development of conventional power plant technology, therefore, is vital, and must be carried out on the basis of proven operational experience. The main incentive behind the development work completed so far has been, and continues to be, the achievement of cost reductions and environmental benefits in the generation of electricity by increasing plant efficiency, and this means that, in both the short and the long term, power plants with improved conventional technology will be used for environmentally acceptable coal-fired power generation.

  1. POSSPOW: Possible Power of Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Giebel, Gregor; Göçmen, Tuhfe; Sørensen, Poul Ejnar

    2013-01-01

    Introduction In recent years, the very large offshore wind farms were designed as wind power plants, including possibilities to contribute to the stability of the grid by offering grid services (also called ancillary services). One of those services is reserve power, which is achieved by down......-regulating the wind farm from its maximum possible power. The power can be ramped up quite quickly, but the influence of wakes makes it difficult to assess the exact amount of down-regulation available to sell. Currently, Transmission System Operators (TSOs) have no real way to determine exactly the possible power...... will be verified on some of the large offshore wind farms owned by Vattenfall, and possibly in a DONG Energy wind farm too. Dedicated experiments to the wind flow in large offshore wind farms are planned. Main body of abstract Modern wind turbines have a SCADA signal called possible power. In normal operation...

  2. Automation of hydroelectric power plants

    Energy Technology Data Exchange (ETDEWEB)

    Grasser, H.S. (Consolidated Papers, Inc., Wisconsin Rapids, WI (US))

    1990-03-01

    This paper describes how the author's company has been automating its hydroelectric generating plants. The early automations were achieved with a relay-type supervisory control system, relay logic, dc tachometer, and a pneumatic gate-position controller. While this system allowed the units to be started and stopped from a remote location, they were operated at an output that was preset by the pneumatic control at the generating site. The supervisory control system at the site provided such information as unit status, generator breaker status, and a binary coded decimal (BCD) value of the pond level. The generating units are started by energizing an on-site relay that sets the pneumatic gate controller to a preset value above the synchronous speed of the hydroelectric generator. The pneumatic controller then opens the water-wheel wicket gates to the preset startup position. As the hydroelectric generator starts to turn, the machine-mounted dc tachometer produces a voltage. At a dc voltage equivalent to synchronous speed, the generator main breaker closes, and a contact from the main breaker starts a field-delay timer. Within a few seconds, the field breaker closes. Once the cycle is complete, a relay changes the pneumatic setpoint to a preset operating point of about 8/10 wicket gate opening.

  3. Performance comparison of different thermodynamic cycles for an innovative central receiver solar power plant

    Science.gov (United States)

    Reyes-Belmonte, Miguel A.; Sebastián, Andrés; González-Aguilar, José; Romero, Manuel

    2017-06-01

    The potential of using different thermodynamic cycles coupled to a solar tower central receiver that uses a novel heat transfer fluid is analyzed. The new fluid, named as DPS, is a dense suspension of solid particles aerated through a tubular receiver used to convert concentrated solar energy into thermal power. This novel fluid allows reaching high temperatures at the solar receiver what opens a wide range of possibilities for power cycle selection. This work has been focused into the assessment of power plant performance using conventional, but optimized cycles but also novel thermodynamic concepts. Cases studied are ranging from subcritical steam Rankine cycle; open regenerative Brayton air configurations at medium and high temperature; combined cycle; closed regenerative Brayton helium scheme and closed recompression supercritical carbon dioxide Brayton cycle. Power cycle diagrams and working conditions for design point are compared amongst the studied cases for a common reference thermal power of 57 MWth reaching the central cavity receiver. It has been found that Brayton air cycle working at high temperature or using supercritical carbon dioxide are the most promising solutions in terms of efficiency conversion for the power block of future generation by means of concentrated solar power plants.

  4. Exergy Analysis of a Syngas-Fueled Combined Cycle with Chemical-Looping Combustion and CO2 Sequestration

    Directory of Open Access Journals (Sweden)

    Álvaro Urdiales Montesino

    2016-08-01

    Full Text Available Fossil fuels are still widely used for power generation. Nevertheless, it is possible to attain a short- and medium-term substantial reduction of greenhouse gas emissions to the atmosphere through a sequestration of the CO2 produced in fuels’ oxidation. The chemical-looping combustion (CLC technique is based on a chemical intermediate agent, which gets oxidized in an air reactor and is then conducted to a separated fuel reactor, where it oxidizes the fuel in turn. Thus, the oxidation products CO2 and H2O are obtained in an output flow in which the only non-condensable gas is CO2, allowing the subsequent sequestration of CO2 without an energy penalty. Furthermore, with shrewd configurations, a lower exergy destruction in the combustion chemical transformation can be achieved. This paper focus on a second law analysis of a CLC combined cycle power plant with CO2 sequestration using syngas from coal and biomass gasification as fuel. The key thermodynamic parameters are optimized via the exergy method. The proposed power plant configuration is compared with a similar gas turbine system with a conventional combustion, finding a notable increase of the power plant efficiency. Furthermore, the influence of syngas composition on the results is investigated by considering different H2-content fuels.

  5. A COMPUTATIONAL WORKBENCH ENVIRONMENT FOR VIRTUAL POWER PLANT SIMULATION

    Energy Technology Data Exchange (ETDEWEB)

    Mike Bockelie; Dave Swensen; Martin Denison; Adel Sarofim; Connie Senior

    2004-12-22

    In this report is described the work effort to develop and demonstrate a software framework to support advanced process simulations to evaluate the performance of advanced power systems. Integrated into the framework are a broad range of models, analysis tools, and visualization methods that can be used for the plant evaluation. The framework provides a tightly integrated problem-solving environment, with plug-and-play functionality, and includes a hierarchy of models, ranging from fast running process models to detailed reacting CFD models. The framework places no inherent limitations on the type of physics that can be modeled, numerical techniques, or programming languages used to implement the equipment models, or the type or amount of data that can be exchanged between models. Tools are provided to analyze simulation results at multiple levels of detail, ranging from simple tabular outputs to advanced solution visualization methods. All models and tools communicate in a seamless manner. The framework can be coupled to other software frameworks that provide different modeling capabilities. Three software frameworks were developed during the course of the project. The first framework focused on simulating the performance of the DOE Low Emissions Boiler System Proof of Concept facility, an advanced pulverized-coal combustion-based power plant. The second framework targeted simulating the performance of an Integrated coal Gasification Combined Cycle - Fuel Cell Turbine (IGCC-FCT) plant configuration. The coal gasifier models included both CFD and process models for the commercially dominant systems. Interfacing models to the framework was performed using VES-Open, and tests were performed to demonstrate interfacing CAPE-Open compliant models to the framework. The IGCC-FCT framework was subsequently extended to support Virtual Engineering concepts in which plant configurations can be constructed and interrogated in a three-dimensional, user-centered, interactive

  6. Advanced virtual energy simulation training and research: IGCC with CO2 capture power plant

    Energy Technology Data Exchange (ETDEWEB)

    Zitney, S.; Liese, E.; Mahapatra, P.; Bhattacharyya, D.; Provost, G.

    2011-01-01

    In this presentation, we highlight the deployment of a real-time dynamic simulator of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture at the Department of Energy's (DOE) National Energy Technology Laboratory's (NETL) Advanced Virtual Energy Simulation Training and Research (AVESTARTM) Center. The Center was established as part of the DOE's accelerating initiative to advance new clean coal technology for power generation. IGCC systems are an attractive technology option, generating low-cost electricity by converting coal and/or other fuels into a clean synthesis gas mixture in a process that is efficient and environmentally superior to conventional power plants. The IGCC dynamic simulator builds on, and reaches beyond, conventional power plant simulators to merge, for the first time, a 'gasification with CO{sub 2} capture' process simulator with a 'combined-cycle' power simulator. Fueled with coal, petroleum coke, and/or biomass, the gasification island of the simulated IGCC plant consists of two oxygen-blown, downward-fired, entrained-flow, slagging gasifiers with radiant syngas coolers and two-stage sour shift reactors, followed by a dual-stage acid gas removal process for CO{sub 2} capture. The combined cycle island consists of two F-class gas turbines, steam turbine, and a heat recovery steam generator with three-pressure levels. The dynamic simulator can be used for normal base-load operation, as well as plant start-up and shut down. The real-time dynamic simulator also responds satisfactorily to process disturbances, feedstock blending and switchovers, fluctuations in ambient conditions, and power demand load shedding. In addition, the full-scope simulator handles a wide range of abnormal situations, including equipment malfunctions and failures, together with changes initiated through actions from plant field operators. By providing a comprehensive IGCC operator training system, the

  7. Strategies in tower solar power plant optimization

    OpenAIRE

    RAMOS, A.; RAMOS, F.

    2012-01-01

    A method for optimizing a central receiver solar thermal electric power plant is studied. We parametrize the plant design as a function of eleven design variables and reduce the problem of finding optimal designs to the numerical problem of finding the minimum of a function of several variables. This minimization problem is attacked with different algorithms both local and global in nature. We find that all algorithms find the same minimum of the objective function. The performance of each of...

  8. Development of a thermal scheme for a cogeneration combined-cycle unit with an SVBR-100 reactor

    Science.gov (United States)

    Kasilov, V. F.; Dudolin, A. A.; Krasheninnikov, S. M.

    2017-02-01

    At present, the prospects for development of district heating that can increase the effectiveness of nuclear power stations (NPS), cut down their payback period, and improve protection of the environment against harmful emissions are being examined in the nuclear power industry of Russia. It is noted that the efficiency of nuclear cogeneration power stations (NCPS) is drastically affected by the expenses for heat networks and heat losses during transportation of a heat carrier through them, since NPSs are usually located far away from urban area boundaries as required for radiation safety of the population. The prospects for using cogeneration power units with small or medium power reactors at NPSs, including combined-cycle units and their performance indices, are described. The developed thermal scheme of a cogeneration combined-cycle unit (CCU) with an SBVR-100 nuclear reactor (NCCU) is presented. This NCCU should use a GE 6FA gasturbine unit (GTU) and a steam-turbine unit (STU) with a two-stage district heating plant. Saturated steam from the nuclear reactor is superheated in a heat-recovery steam generator (HRSG) to 560-580°C so that a separator-superheater can be excluded from the thermal cycle of the turbine unit. In addition, supplemental fuel firing in HRSG is examined. NCCU effectiveness indices are given as a function of the ambient air temperature. Results of calculations of the thermal cycle performance under condensing operating conditions indicate that the gross electric efficiency η el NCCU gr of = 48% and N el NCCU gr = 345 MW can be achieved. This efficiency is at maximum for NCCU with an SVBR-100 reactor. The conclusion is made that the cost of NCCU installed kW should be estimated, and the issue associated with NCCUs siting with reference to urban area boundaries must be solved.

  9. Air bottoming cycle, an alternative to combined cycles. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kaikko, J. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Energy Technology

    2002-02-01

    In this work, the idea of Air Bottoming Cycle (ABC) has been studied. The objectives for the work have been to establish an understanding of the concept for power and heat generation as well as to find - if possible - feasible concepts for future use in the Swedish energy system. Combined cycle in power generation is an established technology. In the conventional combined cycle, a gas turbine works as a topping cycle together with the steam (Rankine) bottoming cycle. In the ABC the steam bottoming cycle is replaced with a gas turbine (Brayton) bottoming cycle having air as a working fluid. The two gas turbines are thermally connected over a gas-to-gas heat exchanger. This concept promises savings in weight and cost, as well as operating benefits, compared to the Rankine bottoming technology. The ABC has been modelled using a heat balance program, and a parametric study for the concept optimisation as well as for off-design analysis has been performed. Performance of the ABC has been compared to other, established technologies. A preliminary economic evaluation has been made. As a result of the study, it is clarified that the Rankine bottoming cycle with steam remains superior to the ABC as regards electrical efficiency in the medium and large power scale. For small-scale applications (<10 MW{sub e}) where the thermodynamic advantage of the Rankine cycle is not dominating any longer and its economy is burdened by the heavy investment structure, the ABC becomes the better alternative for energy utilisation. A preliminary economic evaluation shows that (at energy prices autumn 2000) the ABC is at the same level as the comparable small-scale cogeneration installations. Due to high power-to-heat ratio however, higher electricity prices will favour the ABC. One interesting feature of the ABC is that about 50% of the dissipated low-value heat from the cycle is carried by clean (sterile) air at the temperature around 200 deg C. This air can be utilised for space heating or

  10. Air bottoming cycle, an alternative to combined cycles. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kaikko, J. [Royal Inst. of Techn., Stockholm (Sweden). Dept. of Energy Technology

    2001-10-01

    In this work, the idea of Air Bottoming Cycle (ABC) has been studied. The objectives for the work have been to establish an understanding of the concept for power and heat generation as well as to find - if possible - feasible concepts for future use in the Swedish energy system. Combined cycle in power generation is an established technology. In the conventional combined cycle, a gas turbine works as a topping cycle together with the steam (Rankine) bottoming cycle. In the ABC the steam bottoming cycle is replaced with a gas turbine (Brayton) bottoming cycle having air as a working fluid. The two gas turbines are thermally connected over a gas-to-gas heat exchanger. This concept promises savings in weight and cost, as well as operating benefits, compared to the Rankine bottoming technology. The ABC has been modelled using a heat balance program, and a parametric study for the concept optimisation as well as for off-design analysis has been performed. Performance of the ABC has been compared to other, established technologies. A preliminary economic evaluation has been made. As a result of the study, it is clarified that the Rankine bottoming cycle with steam remains superior to the ABC as regards electrical efficiency in the medium and large power scale. For small-scale applications (<10 MW{sub e}) where the thermodynamic advantage of the Rankine cycle is not dominating any longer and its economy is burdened by the heavy investment structure, the ABC becomes the better alternative for energy utilisation. A preliminary economic evaluation shows that (at energy prices autumn 2000) the ABC is at the same level as the comparable small-scale cogeneration installations. Due to high power-to-heat ratio however, higher electricity prices will favour the ABC. One interesting feature of the ABC is that about 50% of the dissipated low-value heat from the cycle is carried by clean (sterile) air at the temperature around 200 deg C. This air can be utilised for space heating or

  11. Materials availability for fusion power plant construction

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, J.N.; Erickson, L.E.; Engel, R.L.; Foley, T.J.

    1976-09-01

    A preliminary assessment was made of the estimated total U.S. material usage with and without fusion power plants as well as the U.S. and foreign reserves and resources, and U.S. production capacity. The potential environmental impacts of fusion power plant material procurement were also reviewed including land alteration and resultant chemical releases. To provide a general measure for the impact of material procurement for fusion reactors, land requirements were estimated for mining and disposing of waste from mining.

  12. Virtual environments for nuclear power plant design

    Energy Technology Data Exchange (ETDEWEB)

    Brown-VanHoozer, S.A.; Singleterry, R.C. Jr.; King, R.W. [and others

    1996-03-01

    In the design and operation of nuclear power plants, the visualization process inherent in virtual environments (VE) allows for abstract design concepts to be made concrete and simulated without using a physical mock-up. This helps reduce the time and effort required to design and understand the system, thus providing the design team with a less complicated arrangement. Also, the outcome of human interactions with the components and system can be minimized through various testing of scenarios in real-time without the threat of injury to the user or damage to the equipment. If implemented, this will lead to a minimal total design and construction effort for nuclear power plants (NPP).

  13. Understanding Biomass Ignition in Power Plant Mills

    DEFF Research Database (Denmark)

    Schwarzer, Lars; Jensen, Peter Arendt; Glarborg, Peter

    2017-01-01

    Converting existing coal fired power plants to biomass is a readily implemented strategy to increase the share of renewable energy. However, changing from one fuel to another is not straightforward: Experience shows that wood pellets ignite more readily than coal in power plant mills or storages....... This is not very well explained by apply-ing conventional thermal ignition theory. An experimental study at lab scale, using pinewood as an example fuel, was conducted to examine self-heating and self-ignition. Supplemental experiments were performed with bituminous coal. Instead of characterizing ignition...

  14. Reducing water usage with rotary regenerative gas/gas heat exchangers in natural gas-fired power plants with post-combustion carbon capture

    OpenAIRE

    Herraiz, Laura; Hogg, Dougal; Cooper, Jim; Gibbins, Jon; Lucquiaud, Mathieu

    2015-01-01

    It is possible to greatly mitigate the increase of water usage associated with the addition of carbon capture to fossil fuel power generation. This article presents a first-of-a-kind feasibility study of a series of technology options with rotary regenerative gas/gas heat exchangers for the management of the water balance around post-combustion carbon capture process integrated with Combined Cycle Gas Turbine (CCGT) plants with and without exhaust gas recirculation (EGR). Hybrid cooling confi...

  15. Advanced coal-fired power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hebel, G.; Weirich, P.H.

    1988-02-01

    Reconstruction of coal-fired power plants under the aspects of higher economic efficiency and lower emissions has become more interesting as the petroleum and natural gas reserves have become shorter. A number of advanced concepts have been presented in the last few years and tested in experimental facilities, pilot plants and demonstration plants. If construction is envisaged within the next five years, better steam processes and coal gas turbines should be employed. Supercharged steam generators, which will bring about further improvements, will be available by the mid-Nineties.

  16. Chapter 11: Marine and Hydrokinetic Power Generation and Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard; Yu, Yi-Hsiang

    2017-05-18

    Marine and hydrokinetic (MHK) power generation is a relatively new type of renewable generation. Predecessors such as wind power generation, hydropower plant generation, geothermal generation, photovoltaic generation, and solar thermal generation have gained a lot of attention because of their successful implementation. The successful integration of renewable generation into the electric power grid has energized the power system global communities to take the lessons learned, innovations, and market structure to focus on the large potential of MHK to also contribute to the pool of renewable energy generation. This chapter covers the broad spectrum of MHK generation. The state-of-the-art power takeoff methods will be discussed. Types of electrical generators will be presented, and the options for implementation will be presented.

  17. Guinea_WADC00321_ADBG_Guinea_Power_Plants

    Data.gov (United States)

    United Nations Cartographic Section — Data for power plants with total installed generating capacity > 10 mw from the Platts World Electric Power Plants Database (WEPP 2006). Plants were georeferenced...

  18. Strategies in tower solar power plant optimization

    Science.gov (United States)

    Ramos, A.; Ramos, F.

    2012-09-01

    A method for optimizing a central receiver solar thermal electric power plant is studied. We parametrize the plant design as a function of eleven design variables and reduce the problem of finding optimal designs to the numerical problem of finding the minimum of a function of several variables. This minimization problem is attacked with different algorithms both local and global in nature. We find that all algorithms find the same minimum of the objective function. The performance of each of the algorithms and the resulting designs are studied for two typical cases. We describe a method to evaluate the impact of design variables in the plant performance. This method will tell us what variables are key to the optimal plant design and which ones are less important. This information can be used to further improve the plant design and to accelerate the optimization procedure.

  19. Strategies in tower solar power plant optimization

    CERN Document Server

    Ramos, A

    2012-01-01

    A method for optimizing a central receiver solar thermal electric power plant is studied. We parametrize the plant design as a function of eleven design variables and reduce the problem of finding optimal designs to the numerical problem of finding the minimum of a function of several variables. This minimization problem is attacked with different algorithms both local and global in nature. We find that all algorithms find the same minimum of the objective function. The performance of each of the algorithms and the resulting designs are studied for two typical cases. We describe a method to evaluate the impact of design variables in the plant performance. This method will tell us what variables are key to the optimal plant design and which ones are less important. This information can be used to further improve the plant design and to accelerate the optimization procedure.

  20. Gasification combined cycle: Carbon dioxide recovery, transport, and disposal

    Energy Technology Data Exchange (ETDEWEB)

    Doctor, R.D.; Molburg, J.C.; Thimmapuram, P.R.; Berry, G.F.; Livengood, C.D.

    1994-09-01

    The objective of the project is to develop engineering evaluations of technologies for the capture, use, and disposal of carbon dioxide (CO{sub 2}). This project emphasizes CO{sub 2}-capture technologies combined with integrated gasification combined-cycle (IGCC) power systems. Complementary evaluations address CO{sub 2} transportation, CO{sub 2} use, and options for the long-term sequestering of unused CO{sub 2}. Commercially available CO{sub 2}-capture technology is providing a performance and economic baseline against which to compare innovative technologies. The intent is to provide the CO{sub 2} budget, or an {open_quotes}equivalent CO{sub 2}{close_quotes} budget, associated with each of the individual energy-cycle steps, in addition to process design capital and operating costs. The value used for the {open_quotes}equivalent CO{sub 2}{close_quotes} budget is 1 kg of CO{sub 2} per kilowatt-hour (electric). The base case is a 458-MW IGCC system that uses an air-blown Kellogg-Rust-Westinghouse agglomerating fluidized-bed gasifier, Illinois No. 6 bituminous coal feed, and in-bed sulfur removal. Mining, feed preparation, and conversion result in a net electric power production of 454 MW, with a CO{sub 2} release rate of 0.835 kg/kWhe. Two additional life-cycle energy balances for emerging technologies were considered: (1) high-temperature CO{sub 2} separation with calcium- or magnesium-based sorbents, and (2) ambient-temperature facilitated-transport polymer membranes for acid-gas removal.

  1. Electrochemical Power Plant for Terrestrial Flight Platforms Project

    Data.gov (United States)

    National Aeronautics and Space Administration — An electrochemical power plant is proposed by MicroCell Technologies to provide power to terrestrial flight platforms. Our power plant is based upon a proton...

  2. 77 FR 47121 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Units 1 and 2...

    Science.gov (United States)

    2012-08-07

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Units 1 and 2; Exemption 1.0 Background Calvert Cliffs Nuclear Power Plant, LLC (the licensee) is the holder of Renewed..., ``Fatigue Management for Nuclear Power Plant Personnel,'' endorses the Nuclear Energy......

  3. 75 FR 66802 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2010-10-29

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2... Regulatory Commission (the Commission) has granted the request of Calvert Cliffs Nuclear Power Plant, LLC... Operating License Nos. DPR-53 and DPR-69 for the Calvert Cliffs Nuclear Power Plant, Unit......

  4. 76 FR 39908 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2011-07-07

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2.... DPR-53 and DPR-69, for the Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 (CCNPP), respectively... (ISFSI), currently held by Calvert Cliffs Nuclear Power Plant, LLC as owner and licensed......

  5. Sensitivity analysis of parameters affecting carbon footprint of fossil fuel power plants based on life cycle assessment scenarios

    Directory of Open Access Journals (Sweden)

    F. Dalir

    2017-12-01

    Full Text Available In this study a pseudo comprehensive carbon footprint model for fossil fuel power plants is presented. Parameters which their effects are considered in this study include: plant type, fuel type, fuel transmission type, internal consumption of the plant, degradation, site ambient condition, transmission and distribution losses. Investigating internal consumption, degradation and site ambient condition effect on carbon footprint assessment of fossil fuel power plant is the specific feature of the proposed model. To evaluate the model, a sensitivity analysis is performed under different scenarios covering all possible choices for investigated parameters. The results show that carbon footprint of fossil fuel electrical energy that is produced, transmitted and distributed, varies from 321 g CO2 eq/kWh to 980 g CO2 equivalent /kWh. Carbon footprint of combined cycle with natural gas as main fuel is the minimum carbon footprint. Other factors can also cause indicative variation. Fuel type causes a variation of 28%. Ambient condition may change the result up to 13%. Transmission makes the carbon footprint larger by 4%. Internal consumption and degradation influence the result by 2 and 2.5%, respectively. Therefore, to minimize the carbon footprint of fossil fuel electricity, it is recommended to construct natural gas ignited combined cycles in low lands where the temperature is low and relative humidity is high. And the internal consumption is as least as possible and the maintenance and overhaul is as regular as possible.

  6. Turbomachinery for small solar power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bammert, K.; Heikal, H.; Mobarak, A.

    1981-01-01

    Conversion of solar energy into mechanical or electrical energy in small solar power plants (10 bis 500 kW) requires new design criteria, especially with regard to turbomachinery. The cycles suitable for solar power production are affected by many variables such as kinds of working fluid, range of power and maximum cycle temperature determined by the type of collector. Also, the size of the plant will influence the selection of the various components of the plant, especially that of the turbomachinery. A study of a suitable thermodynamic cycle and working fluid is done for different ranges of power and temperature. The working fluids considered are steam, toluene, and refrigerant 113 for the Rankine cycle systems and air for gas turbine systems. For Rankine cycles, turbine selection is a problem in the small power range. This is mainly due to the fact, that for high efficiency the enthalpy drop should be as high as possible, and the mass flow rate of the working fluid through the turbine becomes very small. This, in turn, requires high rotational speed, multistaging and partial admission, especially if water is the working fluid. Toluene offers better design criteria for the turbine in the same temperature and power range (50-200 kW). For the very small range (10 kW) refrigerant 113 or similar should be used, otherwise severe design problems with the turbine will occur. In this power range, photovoltaics may also be considered. For high concentration systems with Brayton cycles (800-1000/sup 0/C) only open-cycle gas turbine plants should be used.

  7. Elk and plants thrive near power lines

    Energy Technology Data Exchange (ETDEWEB)

    Lustre, L.

    1997-11-01

    Butterflies and elk gather in clearings near power line right-of-ways and on the edges of such clearings, where the wild flowers and plants that have widely disappeared as a result of intensive farming and subsurface drainage of fields have found a good habitat. Ornamental coniferous trees, various herbs and assorted berries do well and can be harvested near power lines from woodland clearings once thought unfit for cultivation. IVS, the nationwide network company, takes part in many projects aiming both to increase productive utilization of land areas under power lines and to promote biodiversity

  8. A Market-Based Virtual Power Plant

    DEFF Research Database (Denmark)

    You, Shi; Træholt, Chresten; Poulsen, Bjarne

    2009-01-01

    The fast growing penetration of Distributed Energy Resources (DER) and the continuing trend towards a more liberalized electricity market requires more efficient energy management strategies to handle both emerging technical and economic issues. In this paper, a market-based Virtual Power Plant...

  9. Report on Hawaii Geothermal Power Plant Project

    Energy Technology Data Exchange (ETDEWEB)

    1983-06-01

    The report describes the design, construction, and operation of the Hawaii Geothermal Generator Project. This power plant, located in the Puna District on the island of Hawaii, produces three megawatts of electricity from the steam phase of a geothermal well. (ACR)

  10. Geothermal Cogeneration: Iceland's Nesjavellir Power Plant

    Science.gov (United States)

    Rosen, Edward M.

    2008-01-01

    Energy use in Iceland (population 283,000) is higher per capita than in any other country in the world. Some 53.2% of the energy is geothermal, which supplies electricity as well as heated water to swimming pools, fish farms, snow melting, greenhouses, and space heating. The Nesjavellir Power Plant is a major geothermal facility, supplying both…

  11. Geothermal Cogeneration: Iceland's Nesjavellir Power Plant

    Science.gov (United States)

    Rosen, Edward M.

    2008-01-01

    Energy use in Iceland (population 283,000) is higher per capita than in any other country in the world. Some 53.2% of the energy is geothermal, which supplies electricity as well as heated water to swimming pools, fish farms, snow melting, greenhouses, and space heating. The Nesjavellir Power Plant is a major geothermal facility, supplying both…

  12. Design and evaluation of ship's power plants

    NARCIS (Netherlands)

    Meijer, G.J.; Nienhuis, U.; Vugt, J. van; Folkersma, W.

    1999-01-01

    The cruise industry is host to major changes in the way the skip's power plants are configured. Diesel-electric propulsion has replaced most diesel-mechanic systems for larger ships. Podded propulsion is making serious headway and gas turbines are currently under order. In future, fuel cells, perman

  13. Heber geothermal demonstration power plant. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    The binary power plant is to be a 45 MW net electrical facility deriving energy from the low salinity (14,000 ppM), moderate temperature (360/sup 0/F, 182/sup 0/C) Heber reservoir in Southern California. The optimized baseline design established for the power plant is described, and the design and optimization work that formed the basis for the baseline design is documented. The work accomplished during Phase II, Preliminary Design is also recorded, and a base provided from which detailed plant design could be continued. Related project activities in the areas of licensing, environmental, cost, and schedule are also described. The approach used to establish the Phase II optimized baseline design was to (1) review the EPRI Phase I conceptual design and feasibility studies; (2) identify current design criteria and state-of-the-art technology; and (3) develop a preliminary design optimized to the Heber site based on utiliity standards.

  14. Puertollano IGCC Power Plant; Central de Gasificacion Integrada en Ciclo Combinado de Puertollano

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The Puertollano IGCC Power Plant, rated 335 MW and located in Puertollano, Ciudad Real, in the central area of Spain, is a project led by ELCOGAS, a company incorporated by the European utilities ENDESA, ELECTRICITE DE FRANCE, IBERDROLA HIDROCANTABRICO ELECTRICIDADE DE PURTUGAL, ENEL and NATIONAL POWER and the technology and equipment suppliers SIEMENS, KRUPP UHDE and BABCOCK WILCOX ESPANOLA. IGCC technology is based in a process of coal gasification to obtain a clean combustion synthetic gas, integrated with a combined cycle, agas and steam, electricity-generating unit. The energy efficiency which is aimed to achieve at the Plant is 46% in ISO conditions. The Gasification unit uses the process of pressurised entrained flow for coal gasification. The gas is produced by the reaction of coal with oxygen at high temperatures, of up to 1600 degree centigree. This process is capable of gasifying a wide variety of types and qualities of coal for the production of a synthetic fuel gas. In the case of Puertollano, the raw fuel is a 50% mixture by weight of local coal and petroleum coke. The oxygen needed in the process and the nitrogen used for covering the fuel is generated in the Air Separation. The Gas Cleaning and Sulphur Recovery Unit clean the gases from contaminants and solid particles before to send them to the Gas Turbine. The clean gas is burnt in gas turbine of the Combined Cycle Plant, producing electricity. The exhaust gases feed a heat recovery steam generator, which produces steam used to generate additional electricity in a conventional steam turbine. The gas turbine is capable of operating both with synthetic gas and with natural gas, allowing operation flexibility. The net output of the plant up to December 1999 was 3.061 GWh, from them 344 GWh were produced with synthetic gas. This project has an important technological value, being the first power plant which uses coal gasification to feed a combined cycle in Spain and being also the biggest power plant

  15. Recent Advances in Ocean Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Kang-Heon Lee

    2015-10-01

    Full Text Available In this paper, recent advances in Ocean Nuclear Power Plants (ONPPs are reviewed, including their general arrangement, design parameters, and safety features. The development of ONPP concepts have continued due to initiatives taking place in France, Russia, South Korea, and the United States. Russia’s first floating nuclear power stations utilizing the PWR technology (KLT-40S and the spar-type offshore floating nuclear power plant designed by a research group in United States are considered herein. The APR1400 and SMART mounted Gravity Based Structure (GBS-type ONPPs proposed by a research group in South Korea are also considered. In addition, a submerged-type ONPP designed by DCNS of France is taken into account. Last, issues and challenges related to ONPPs are discussed and summarized.

  16. Market integration of Virtual Power Plants

    DEFF Research Database (Denmark)

    Petersen, Mette Kirschmeyer; Hansen, Lars Henrik; Bendtsen, Jan Dimon

    2013-01-01

    We consider a direct control Virtual Power Plant, which is given the task of maximizing the profit of a portfolio of flexible consumers by trading flexibility in Energy Markets. Spot price optimization has been quite intensively researched in Smart Grid literature lately. In this work, however, we...... develop a three stage market model, which includes Day-Ahead (Spot), Intra-Day and Regulating Power Markets. This allows us to test the hypothesis that the Virtual Power Plant can generate additional profit by trading across several markets. We find that even though profits do increase as more markets...... are penetrated, the size of the profit is strongly dependent on the type of flexibility considered. We also find that penetrating several markets makes profits surprisingly robust to spot price prediction errors....

  17. Fossil fuel-fired power generation. Case studies of recently constructed coal- and gas-fired plants

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C. [IEA Clean Coal Centre, London (United Kingdom)

    2007-10-23

    To meet future energy demand growth and replace older or inefficient units, a large number of fossil fuel-fired plants will be required to be built worldwide in the next decade. Yet CO{sub 2} emissions from fossil-fired power generation are a major contributor to climate change. As a result, new plants must be designed and operated at highest efficiency both to reduce CO{sub 2} emissions and to facilitate deployment of CO{sub 2} capture and storage in the future. The series of case studies in this report, which respond to a request to the IEA from the G8 Summit in July 2005, were conducted to illustrate what efficiency is achieved now in modern plants in different parts of the world using different grades of fossil fuels. The plants were selected from different geographical areas, because local factors influence attainable efficiency. The case studies include pulverized coal combustion (PCC) with both subcritical and supercritical (very high pressure and temperature) steam turbine cycles, a review of current and future applications of coal-fuelled integrated gasification combined cycle plants (IGCC), and a case study of a natural gas fired combined cycle plant to facilitate comparisons. The results of these analyses show that the technologies for high efficiency (low CO{sub 2} emission) and very low conventional pollutant emissions (particulates, SO{sub 2}, NOx) from fossil fuel-fired power generation are available now through PCC, IGCC or NGCC at commercially acceptable cost. This report contains comprehensive technical and indicative cost information for modern fossil fuel-fired plants that was previously unavailable. It serves as a valuable sourcebook for policy makers and technical decision makers contemplating decisions to build new fossil fuel-fired power generation plants.

  18. Comprehensive Exergy Analysis of Three IGCC Power Plant Configurations with CO2 Capture

    Directory of Open Access Journals (Sweden)

    Nicholas S. Siefert

    2016-08-01

    Full Text Available We have conducted comprehensive exergy analyses of three integrated gasification combined cycle with carbon capture and storage (IGCC-CCS power plant configurations: (1 a baseline model using Selexol™ for H2S/CO2 removal; (2 a modified version that adds a H2-selective membrane before the Selexol™ acid gas removal system; and (3 a modified baseline version that uses a CO2-selective membrane before the Selexol™ acid gas removal system. While holding the coal input flow rate and the CO2 captured flow rates constant, it was determined that the H2-selective membrane case had a higher net power output (584 MW compared to the baseline (564 MW and compared to the CO2-selective membrane case (550 MW. Interestingly, the CO2-selective membrane case destroyed the least amount of exergy within the power plant (967 MW, compared with the Baseline case (999 MW and the H2-membrane case (972 MW. The main problem with the CO2-selective membrane case was the large amount of H2 (48 MW worth of H2 chemical exergy remaining within the supercritical CO2 that exits the power plant. Regardless of the CO2 capture process used, the majority of the exergy destruction occurred in the gasifier (305 MW and gas turbine (~380 MW subsystems, suggesting that these two areas should be key areas of focus of future improvements.

  19. Model-Based Power Plant Master Control

    Energy Technology Data Exchange (ETDEWEB)

    Boman, Katarina; Thomas, Jean; Funkquist, Jonas

    2010-08-15

    The main goal of the project has been to evaluate the potential of a coordinated master control for a solid fuel power plant in terms of tracking capability, stability and robustness. The control strategy has been model-based predictive control (MPC) and the plant used in the case study has been the Vattenfall power plant Idbaecken in Nykoeping. A dynamic plant model based on nonlinear physical models was used to imitate the true plant in MATLAB/SIMULINK simulations. The basis for this model was already developed in previous Vattenfall internal projects, along with a simulation model of the existing control implementation with traditional PID controllers. The existing PID control is used as a reference performance, and it has been thoroughly studied and tuned in these previous Vattenfall internal projects. A turbine model was developed with characteristics based on the results of steady-state simulations of the plant using the software EBSILON. Using the derived model as a representative for the actual process, an MPC control strategy was developed using linearization and gain-scheduling. The control signal constraints (rate of change) and constraints on outputs were implemented to comply with plant constraints. After tuning the MPC control parameters, a number of simulation scenarios were performed to compare the MPC strategy with the existing PID control structure. The simulation scenarios also included cases highlighting the robustness properties of the MPC strategy. From the study, the main conclusions are: - The proposed Master MPC controller shows excellent set-point tracking performance even though the plant has strong interactions and non-linearity, and the controls and their rate of change are bounded. - The proposed Master MPC controller is robust, stable in the presence of disturbances and parameter variations. Even though the current study only considered a very small number of the possible disturbances and modelling errors, the considered cases are

  20. Configuration management in nuclear power plants

    CERN Document Server

    2003-01-01

    Configuration management (CM) is the process of identifying and documenting the characteristics of a facility's structures, systems and components of a facility, and of ensuring that changes to these characteristics are properly developed, assessed, approved, issued, implemented, verified, recorded and incorporated into the facility documentation. The need for a CM system is a result of the long term operation of any nuclear power plant. The main challenges are caused particularly by ageing plant technology, plant modifications, the application of new safety and operational requirements, and in general by human factors arising from migration of plant personnel and possible human failures. The IAEA Incident Reporting System (IRS) shows that on average 25% of recorded events could be caused by configuration errors or deficiencies. CM processes correctly applied ensure that the construction, operation, maintenance and testing of a physical facility are in accordance with design requirements as expressed in the d...

  1. ORC-mall scale power plant

    Energy Technology Data Exchange (ETDEWEB)

    Jokinen, T. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Electromechanics

    1998-12-31

    In the conversion of low temperature heat into electricity, the greatest efficiency is obtained by using a Rankine cycle. The Organic Rankine cycle (ORC) is a Rankine cycle where an organic fluid is used instead of water as the working fluid. In the conventional ORC-solution, an axial turbine drives a standard generator through a high-speed gearbox. The system includes a separate feed pump, vacuum pump, lubrication system and requires several saft seals. The seals of the turbine have a limited working life in particular due to the high speed required. Thus, the entire present conventional ORC-plant is rather complicated and requires maintenance. To avoid these problems, a project was initiated at the Lappeenranta University of Technology to develop a high-speed, process fluid lubricated turbogenerator-feed pump as the prime mover of the ORC. The project has been continued in co-operation with the Helsinki University of Technology under the NEMO 2 program, the main goal being to build a demonstration power plant and to commercialise the project. The goals of the project were: (1) to model the ORC process, turbogenerator, and inverter, (2) to simulate the power plant in different normal and abnormal states, (3) to assess the advantages and disadvantages of various control systems, (4) to study network disturbances such as voltage and current harmonics and to research ways of reducing these disturbances, (5) to optimise heat exchanging surfaces and process parameters, and (6) to participate in the design of the demonstration power plant

  2. BOILER MATERIALS FOR ULTRASUPERCRITICAL COAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    R. Viswanathan; K. Coleman; R.W. Swindeman; J. Sarver; J. Blough; W. Mohn; M. Borden; S. Goodstine; I. Perrin

    2003-10-20

    The principal objective of this project is to develop materials technology for use in ultrasupercritical (USC) plant boilers capable of operating with 760 C (1400 F), 35 MPa (5000 psi) steam. This project has established a government/industry consortium to undertake a five-year effort to evaluate and develop of advanced materials that allow the use of advanced steam cycles in coal-based power plants. These advanced cycles, with steam temperatures up to 760 C, will increase the efficiency of coal-fired boilers from an average of 35% efficiency (current domestic fleet) to 47% (HHV). This efficiency increase will enable coal-fired power plants to generate electricity at competitive rates (irrespective of fuel costs) while reducing CO{sub 2} and other fuel-related emissions by as much as 29%. Success in achieving these objectives will support a number of broader goals. First, from a national prospective, the program will identify advanced materials that will make it possible to maintain a cost-competitive, environmentally acceptable coal-based electric generation option. High sulfur coals will specifically benefit in this respect by having these advanced materials evaluated in high-sulfur coal firing conditions and from the significant reductions in waste generation inherent in the increased operational efficiency. Second, from a national prospective, the results of this program will enable domestic boiler manufacturers to successfully compete in world markets for building high-efficiency coal-fired power plants.

  3. Optimal control system design for IGCC power plants with CO2 capture

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.; Bhattacharyya, D.; Turton, R.; Zitney, S.

    2012-01-01

    Designing an optimal control system for an integrated gasification combined cycle (IGCC) power plant with CO2 capture addresses the challenge of efficiently operating and controlling a coal-fed IGCC plant with the desired extent of CO2 capture in the face of disturbances without violating operational and environmental constraints. The control system design needs to optimize a desired scalar objective function while satisfying all the operational and environmental constraints in the presence of measured and unmeasured disturbances. Various objective functions can be considered for the control system design such as maximization of profit, maximization of the power produced, or minimization of the auxiliary power. The design of such a control system makes the plant suitable to play an active role in the smart grid era as the plant will have the required agility. In addition, other penalty function(s) such as emission penalties for CO2 or other criteria pollutants can be considered in the framework as well as losses associated with any hydrogen or carbon monoxide loses. The proposed control system design is performed in two stages. In the first stage, a top-down analysis is performed to generate a list of controlled, manipulated, and disturbance variables considering a scalar operational objective and other process constraints. In the second stage, a bottom-up approach for simultaneous design of the control structure and the controllers is used. In this paper, the first stage of the two-stage approach is applied to the IGCC’s acid gas removal (AGR) process which removes both H2S and CO2 from the shifted synthesis gas. While these results are still preliminary, they demonstrate the application of the proposed approach for a commercial-scale plant and show some interesting results related to controlled variable selection. Such an approach can be followed not only to design control systems for new power plants, but also to retrofit control systems for existing plants

  4. Market integration of Virtual Power Plants

    DEFF Research Database (Denmark)

    Petersen, Mette Kirschmeyer; Hansen, Lars Henrik; Bendtsen, Jan Dimon;

    2013-01-01

    We consider a direct control Virtual Power Plant, which is given the task of maximizing the profit of a portfolio of flexible consumers by trading flexibility in Energy Markets. Spot price optimization has been quite intensively researched in Smart Grid literature lately. In this work, however, w...... are penetrated, the size of the profit is strongly dependent on the type of flexibility considered. We also find that penetrating several markets makes profits surprisingly robust to spot price prediction errors.......We consider a direct control Virtual Power Plant, which is given the task of maximizing the profit of a portfolio of flexible consumers by trading flexibility in Energy Markets. Spot price optimization has been quite intensively researched in Smart Grid literature lately. In this work, however, we...... develop a three stage market model, which includes Day-Ahead (Spot), Intra-Day and Regulating Power Markets. This allows us to test the hypothesis that the Virtual Power Plant can generate additional profit by trading across several markets. We find that even though profits do increase as more markets...

  5. Nuclear power plant operation and training

    Energy Technology Data Exchange (ETDEWEB)

    Sanae, Katsushige [Tokyo Electric Power Co., Inc. (Japan); Mitsumori, Kojiro

    1997-07-01

    In this report, the system for operation of a nuclear power plant and the qualities required for its operators were summarized. In Kashiwazaki-Kariwa Atomic Power Plant of the Tokyo Electric Power Co., Inc. operation is continuously made by 6 groups containing each 10 workers on three shifts. A group including the person in charge participates in the operation through cooperation of the control center and the respective spots. The group leaders are chosen from those approved as a person responsible to its operation. The conditions for the person responsible were as follows: to receive simulator training for senior operator, to have more than 7 years experience of operating a nuclear power plant, to pass a practical examination on the ordinary operation and the emergency one, to receive a training course to master the knowledge and techniques for operating an atomic reactor and to success the oral examination on practical knowledge required to perform the duty. Further, the simulators for ABWR training produced by Toshiba Corp. and Hitachi Ltd. were introduced as an example. And the practical training procedures to manipulate the simulator were presented. (M.N.)

  6. Energy comparison between solar thermal power plant and photovoltaic power plant

    Science.gov (United States)

    Novosel, Urška; Avsec, Jurij

    2017-07-01

    The combined use of renewable energy and alternative energy systems and better efficiency of energy devices is a promising approach to reduce effects due to global warming in the world. On the basis of first and second law of thermodynamics we could optimize the processes in the energy sector. The presented paper shows the comparison between solar thermal power plant and photovoltaic power plant in terms of energy, exergy and life cycle analysis. Solar thermal power plant produces electricity with basic Rankine cycle, using solar tower and solar mirrors to produce high fluid temperature. Heat from the solar system is transferred by using a heat exchanger to Rankine cycle. Both power plants produce hydrogen via electrolysis. The paper shows the global efficiency of the system, regarding production of the energy system.

  7. Safety in nuclear power plants in India

    Directory of Open Access Journals (Sweden)

    Deolalikar R

    2008-01-01

    Full Text Available Safety in nuclear power plants (NPPs in India is a very important topic and it is necessary to dissipate correct information to all the readers and the public at large. In this article, I have briefly described how the safety in our NPPs is maintained. Safety is accorded overriding priority in all the activities. NPPs in India are not only safe but are also well regulated, have proper radiological protection of workers and the public, regular surveillance, dosimetry, approved standard operating and maintenance procedures, a well-defined waste management methodology, proper well documented and periodically rehearsed emergency preparedness and disaster management plans. The NPPs have occupational health policies covering periodic medical examinations, dosimetry and bioassay and are backed-up by fully equipped Personnel Decontamination Centers manned by doctors qualified in Occupational and Industrial Health. All the operating plants are ISO 14001 and IS 18001 certified plants. The Nuclear Power Corporation of India Limited today has 17 operating plants and five plants under construction, and our scientists and engineers are fully geared to take up many more in order to meet the national requirements.

  8. Safety in nuclear power plants in India.

    Science.gov (United States)

    Deolalikar, R

    2008-12-01

    Safety in nuclear power plants (NPPs) in India is a very important topic and it is necessary to dissipate correct information to all the readers and the public at large. In this article, I have briefly described how the safety in our NPPs is maintained. Safety is accorded overriding priority in all the activities. NPPs in India are not only safe but are also well regulated, have proper radiological protection of workers and the public, regular surveillance, dosimetry, approved standard operating and maintenance procedures, a well-defined waste management methodology, proper well documented and periodically rehearsed emergency preparedness and disaster management plans. The NPPs have occupational health policies covering periodic medical examinations, dosimetry and bioassay and are backed-up by fully equipped Personnel Decontamination Centers manned by doctors qualified in Occupational and Industrial Health. All the operating plants are ISO 14001 and IS 18001 certified plants. The Nuclear Power Corporation of India Limited today has 17 operating plants and five plants under construction, and our scientists and engineers are fully geared to take up many more in order to meet the national requirements.

  9. DCS emulator development for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Y. [Hitachi Canada Ltd., Power and Industry Div., Mississauga, Ontario (Canada); Ishii, K.; Chiba, D. [Hitachi Ltd., Information and Control Systems Div., Ibaraki-ken (Japan)

    2009-07-01

    Continual training of operators is one of the principal means by which Nuclear Power Plant (NPP) operational efficiency can be improved. Since this training cannot take place in the actual NPP, NPP simulator applications must be used instead. While digitalization scope of Instrumentation and Control (I and C) systems has been expanded to the entire plant by using Distributed Control System (DCS) implementation, Hitachi has implemented DCS emulator on a general purpose Personal Computer (PC) and applied it to simulator applications. This paper reviews such DCS emulator development for NPP by Hitachi. (author)

  10. Coal Moisture Estimation in Power Plant Mills

    DEFF Research Database (Denmark)

    Andersen, Palle; Bendtsen, Jan Dimon; Pedersen, Tom S.;

    2009-01-01

    Knowledge of moisture content in raw coal feed to a power plant coal mill is of importance for efficient operation of the mill. The moisture is commonly measured approximately once a day using offline chemical analysis methods; however, it would be advantageous for the dynamic operation...... of the plant if an on-line estimate were available. In this paper we such propose an on-line estimator (an extended Kalman filter) that uses only existing measurements. The scheme is tested on actual coal mill data collected during a one-month operating period, and it is found that the daily measured moisture...

  11. Concept and controllability of virtual power plant

    Energy Technology Data Exchange (ETDEWEB)

    Setiawan, E.A.

    2007-07-01

    In the end of 20th century the conception of electrical power supply is morphing gradually from centralized into decentralized system, indicated by increasing the installation of distributed generation on the main grid. With emerging of advanced communication and information technology, the aggregation control of several DG units can be developed as virtual power plant in order to provide added-value to the electric power system. This thesis presents definitions and types of Virtual Power Plants (VPP), then developing control through numerical simulation. The thesis proposes three DG controls namely Basic Autocontrol System (BAS), Smart Autocontrol System (SAS) and Tracking Efficiency Autocontrol System (TEAS). The BAS controls the DG output power with the objective to cover the local load demand. The drawback of this system is that the coordination among DG units is not established yet. In contrast to the BAS, the SAS has a control coordination centre which is responsible of controlling a certain number of DG units. The SAS controls and coordinates the operation of the dedicated DG units in order to minimize power exchange with the superior grid. However the efficiency issue is not considered at two previous control systems, therefore the TEAS was developed. Principally this system is similar to the SAS in terms of information exchange but additionally optimizes the operation efficiency of DG units. This is accomplished by tracking the systems' most efficient operation point. All control systems have been implemented into a simulation environment. The simulation results show that all developed control systems are capable to minimize the power exchange with the superior grid. The systems are able to follow changing load conditions. Furthermore the simulation results prove the ability of TEAS to optimize the system efficiency. Finally the contribution of VPP to voltage regulation is investigated with several scenarios. The influence of both, active and reactive

  12. Waste heat recovery options in a large gas-turbine combined power plant

    Science.gov (United States)

    Upathumchard, Ularee

    This study focuses on power plant heat loss and how to utilize the waste heat in energy recovery systems in order to increase the overall power plant efficiency. The case study of this research is a 700-MW natural gas combined cycle power plant, located in a suburban area of Thailand. An analysis of the heat loss of the combustion process, power generation process, lubrication system, and cooling system has been conducted to evaluate waste heat recovery options. The design of the waste heat recovery options depends to the amount of heat loss from each system and its temperature. Feasible waste heat sources are combustion turbine (CT) room ventilation air and lubrication oil return from the power plant. The following options are being considered in this research: absorption chillers for cooling with working fluids Ammonia-Water and Water-Lithium Bromide (in comparison) and Organic Rankine Cycle (ORC) with working fluids R134a and R245fa. The absorption cycles are modeled in three different stages; single-effect, double-effect and half-effect. ORC models used are simple ORC as a baseline, ORC with internal regenerator, ORC two-phase flash expansion ORC and ORC with multiple heat sources. Thermodynamic models are generated and each system is simulated using Engineering Equation Solver (EES) to define the most suitable waste heat recovery options for the power plant. The result will be synthesized and evaluated with respect to exergy utilization efficiency referred as the Second Law effectiveness and net output capacity. Results of the models give recommendation to install a baseline ORC of R134a and a double-effect water-lithium bromide absorption chiller, driven by ventilation air from combustion turbine compartment. The two technologies yield reasonable economic payback periods of 4.6 years and 0.7 years, respectively. The fact that this selected power plant is in its early stage of operation allows both models to economically and effectively perform waste heat

  13. FACTS Devices for Large Wind Power Plants

    DEFF Research Database (Denmark)

    Adamczyk, Andrzej Grzegorz; Teodorescu, Remus; Rodriguez, Pedro;

    2010-01-01

    Growing number of wind turbines is changing electricity generation profile all over the world. However, high wind energy penetration affects power system safety and stability. For this reason transmission system operators (TSO) impose more stringent connection requirements on the wind power plant...... (WPP) owners. On the other hand flexible AC transmission systems (FACTS) devices offer enhancement of grid stability and can facilitate grid code compliance for WPP. In this paper state-of-the-art in FACTS for large WPPs with AC connection is given. FACTS devices (excluding HVDC) with their properties...... are described. Academic and industrial research in FACTS applicability for WPPs is summarized....

  14. Improved repowering techniques for power plants

    DEFF Research Database (Denmark)

    Houbak, Niels; Andersen, Simon E.; Petersen, Stiig Bo

    1998-01-01

    Repowering of existing coal-fired power plants is often accomplished by adding gas turbines. In this paper we assume that the gas turbine exhaust is used for feed water preheating.Typical gas turbine exhaust temperatures are in the range 450-600C whereas typical boiler inlet temperatures are 250......-300C. The big difference in temperature between exhaust and water prevents an efficient exchange of heat. One way to lower the exhaust temperature is to expand the gas to sub atmospheric pressure. The result is a 50% increase in possible installed gas turbine power....

  15. Market Integration of Virtual Power Plants

    DEFF Research Database (Denmark)

    Petersen, Mette Kirschmeyer

    is the technical and commercial entity in charge of mobilization and control of flexible consumers. This Thesis addresses some of the challenges relating to the Smart Grid and Virtual Power Plant visions with special attention to flexibility, value creation and portfolio coordination. The term flexibility....... It does however significantly sharpen the discussion of the flexibility concept and provides a categorization of flexible systems. This Thesis also investigates what value can be created from the different types of flexibility by assuming that the Virtual Power Plant will generate profit by trading...... flexibility in electricity markets. Based on the taxonomy and a model of the Nordic electricity markets it is explored how differences between flexibility types affects profit margin. It is found that revenue potential depends strongly on the quality of flexibility. Finally the subject of portfolio...

  16. JOINT ECONOMIC AND ENVIRONMENTAL OPTIMIZATION OF HYBRID POWER SUPPLY FOR LARGE SCALE RO-DESALINATION PLANT: WITH AND WITHOUT CO2 SEQUESTRATION

    Directory of Open Access Journals (Sweden)

    EMAN A. TORA

    2016-07-01

    Full Text Available In this paper, a multi- objective optimization approach is introduced to define a hybrid power supply system for a large scale RO- desalination plant. The target is to integrate a number of locally available energy resources to generate the electricity demand of the RO- desalination plant with minimizing both the electricity generation cost and the greenhouse gas emissions whereby carbon dioxide sequestration may be an option. The considered energy resources and technologies are wind turbines, solar PV, combined cycles with natural gas turbines, combined cycles with coal gasification, pulverized coal with flue gas desulfurization, and biomass combined heat and power CHP. These variable energy resources are investigated under different constraints on the renewable energy contribution. Likewise, the effect of carbon dioxide sequestration is included. Accordingly, five scenarios have been analyzed. Trade- offs between the minimum electricity generation cost and the minimum greenhouse gas emissions have been determined and represented in Pareto curves using the constraint method (. The results highlight that among the studied fossil fuel technologies, the integrated combined cycle natural gas turbines can provide considerable fraction of the needed power supply. Likewise, wind turbines are the most effective technology among renewable energy options. When CO2 sequestration applied, the costs increase and significant changes in the optimum combination of renewable energy resources have been monitored. In that case, solar PV starts to appreciably compete. The optimum mix of energy resources extends to include biomass CHP as well.

  17. Advanced Power Plant Development and Analysis Methodologies

    Energy Technology Data Exchange (ETDEWEB)

    A.D. Rao; G.S. Samuelsen; F.L. Robson; B. Washom; S.G. Berenyi

    2006-06-30

    Under the sponsorship of the U.S. Department of Energy/National Energy Technology Laboratory, a multi-disciplinary team led by the Advanced Power and Energy Program of the University of California at Irvine is defining the system engineering issues associated with the integration of key components and subsystems into advanced power plant systems with goals of achieving high efficiency and minimized environmental impact while using fossil fuels. These power plant concepts include 'Zero Emission' power plants and the 'FutureGen' H2 co-production facilities. The study is broken down into three phases. Phase 1 of this study consisted of utilizing advanced technologies that are expected to be available in the 'Vision 21' time frame such as mega scale fuel cell based hybrids. Phase 2 includes current state-of-the-art technologies and those expected to be deployed in the nearer term such as advanced gas turbines and high temperature membranes for separating gas species and advanced gasifier concepts. Phase 3 includes identification of gas turbine based cycles and engine configurations suitable to coal-based gasification applications and the conceptualization of the balance of plant technology, heat integration, and the bottoming cycle for analysis in a future study. Also included in Phase 3 is the task of acquiring/providing turbo-machinery in order to gather turbo-charger performance data that may be used to verify simulation models as well as establishing system design constraints. The results of these various investigations will serve as a guide for the U. S. Department of Energy in identifying the research areas and technologies that warrant further support.

  18. Advanced Power Plant Development and Analyses Methodologies

    Energy Technology Data Exchange (ETDEWEB)

    G.S. Samuelsen; A.D. Rao

    2006-02-06

    Under the sponsorship of the U.S. Department of Energy/National Energy Technology Laboratory, a multi-disciplinary team led by the Advanced Power and Energy Program of the University of California at Irvine is defining the system engineering issues associated with the integration of key components and subsystems into advanced power plant systems with goals of achieving high efficiency and minimized environmental impact while using fossil fuels. These power plant concepts include ''Zero Emission'' power plants and the ''FutureGen'' H{sub 2} co-production facilities. The study is broken down into three phases. Phase 1 of this study consisted of utilizing advanced technologies that are expected to be available in the ''Vision 21'' time frame such as mega scale fuel cell based hybrids. Phase 2 includes current state-of-the-art technologies and those expected to be deployed in the nearer term such as advanced gas turbines and high temperature membranes for separating gas species and advanced gasifier concepts. Phase 3 includes identification of gas turbine based cycles and engine configurations suitable to coal-based gasification applications and the conceptualization of the balance of plant technology, heat integration, and the bottoming cycle for analysis in a future study. Also included in Phase 3 is the task of acquiring/providing turbo-machinery in order to gather turbo-charger performance data that may be used to verify simulation models as well as establishing system design constraints. The results of these various investigations will serve as a guide for the U. S. Department of Energy in identifying the research areas and technologies that warrant further support.

  19. Thermodynamics in nuclear power plant systems

    CERN Document Server

    Zohuri, Bahman

    2015-01-01

    This book covers the fundamentals of thermodynamics required to understand electrical power generation systems, honing in on the application of these principles to nuclear reactor powersystems. It includes all the necessary information regarding the fundamental laws to gain a complete understanding and apply them specifically to the challenges of operating nuclear plants. Beginning with definitions of thermodynamic variables such as temperature, pressure and specific volume, the book then explains the laws in detail, focusing on pivotal concepts such as enthalpy and entropy, irreversibilit

  20. Virtual power plants with electric vehicles

    OpenAIRE

    Grau, Iñaki; Papadopoulos, Panagiotis; Skarvelis-Kazakos, Spyros; Cipcigan, Liana M.; Jenkins, Nick

    2010-01-01

    The benefits of integrating aggregated Electric Vehicles (EV) within the Virtual Power Plant (VPP) concept, are addressed. Two types of EV aggregators are identified: i) Electric Vehicle Residential Aggregator (EVRA), which is responsible for the management of dispersed and clustered EVs in a residential area and ii) Electric Vehicle Commercial Aggregator (EVCA), which is responsible for the management of EVs clustered in a single car park. A case study of a workplace EVCA is presented, provi...

  1. Alloy Design for a Fusion Power Plant

    OpenAIRE

    Kemp, Richard

    2006-01-01

    Fusion power is generated when hot deuterium and tritium nuclei react, producing alpha particles and 14 MeV neutrons. These neutrons escape the reaction plasma and are absorbed by the surrounding material structure of the plant, transferring the heat of the reaction to an external cooling circuit. In such high-energy neutron irradiation environments, extensive atomic displacement damage and transmutation production of helium affect the mechanical properties of materials. Among these effect...

  2. Safety in nuclear power plants in India

    OpenAIRE

    Deolalikar R

    2008-01-01

    Safety in nuclear power plants (NPPs) in India is a very important topic and it is necessary to dissipate correct information to all the readers and the public at large. In this article, I have briefly described how the safety in our NPPs is maintained. Safety is accorded overriding priority in all the activities. NPPs in India are not only safe but are also well regulated, have proper radiological protection of workers and the public, regular surveillance, dosimetry, approved standard operat...

  3. Coal gasification power plant and process

    Science.gov (United States)

    Woodmansee, Donald E.

    1979-01-01

    In an integrated coal gasification power plant, a humidifier is provided for transferring as vapor, from the aqueous blowdown liquid into relatively dry air, both (I) at least a portion of the water contained in the aqueous liquid and (II) at least a portion of the volatile hydrocarbons therein. The resulting humidified air is advantageously employed as at least a portion of the hot air and water vapor included in the blast gas supplied via a boost compressor to the gasifier.

  4. Construct ability Improvement for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dae Soo; Lee, Jong Rim; Kim, Jong Ku [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    The purpose of this study was to identify methods for improving the construct ability of nuclear power plants. This study reviewed several references of current construction practices of domestic and overseas nuclear plants in order to identify potential methods for improving construct ability. The identified methods for improving construct ability were then evaluated based on the applicability to domestic nuclear plant construction. The selected methods are expected to reduce the construction period, improve the quality of construction, cost, safety, and productivity. Selection of which methods should be implemented will require further evaluation of construction modifications, design changes, contract revisions. Among construction methods studied, platform construction methods can be applied through construction sequence modification without significant design changes, and Over the Top construction method of the NSSS, automatic welding of RCL pipes, CLP modularization, etc., are considered to be applied after design modification and adjustment of material lead time. (author). 49 refs., figs., tabs.

  5. Fatigue monitoring in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.G.; Shah, V.N. [Idaho National Engineering Laboratory, Idaho Falls, ID (United States)

    1995-04-01

    This paper summarizes fatigue monitoring methods and surveys their application in the nuclear power industry. The paper is based on a review of the technical literature. Two main reasons for fatigue monitoring are more frequent occurrence of some transients than that assumed in the fatigue design analysis and the discovery of stressors that were not included in the fatigue design analysis but may cause significant fatigue damage at some locations. One fatigue monitoring method involves use of plant operating data and procedures to update the fatigue usage. Another method involves monitoring of plant operating parameters using existing, or if needed, supplementary plant instrumentation for online computation of fatigue usage. Use of fatigue monitoring has better defined the operational transients. Most operational transients have been found less severe and fewer in numbers than anticipated in the design fatigue analysis. Use of fatigue monitoring has assisted in quantifying newly discovered stressors and has helped in detecting the presence of thermal stratification of unsuspected locations.

  6. Power plant productivity improvement in New York

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-03-01

    The New York Public Service Commission (PSC), under contract with the US Department of Energy (DOE), began a joint program in September 1978 to improve the productivity of coal and nuclear electric generating units in New York State. The project had dual objectives: to ensure that the utilities in New York State have or develop a systematic permanent, cost-effective productivity improvement program based on sound engineering and economic considerations, and to develop a model program for Power Plant Productivity Improvement, which, through DOE, can also be utilized by other regulatory commissions in the country. To accomplish these objectives, the program was organized into the following sequence of activities: compilation and analysis of power plant performance data; evaluation and comparison of utility responses to outage/derating events; power plant productivity improvement project cost-benefit analysis; and evaluation of regulatory procedures and policies for improving productivity. The program that developed for improving the productivity of coal units is substantially different than for nuclear units. Each program is presented, and recommendations are made for activities of both the utilities and regulatory agencies which will promote improved productivity.

  7. Methodology for Assessment of Inertial Response from Wind Power Plants

    DEFF Research Database (Denmark)

    Altin, Müfit; Teodorescu, Remus; Bak-Jensen, Birgitte;

    2012-01-01

    High wind power penetration levels result in additional requirements from wind power in order to improve frequency stability. Replacement of conventional power plants with wind power plants reduces the power system inertia due to the wind turbine technology. Consequently, the rate of change...

  8. Economic analysis of large solar power plants

    Science.gov (United States)

    Klaiss, Helmut; Nitsch, Joachim; Geyer, Michael

    1987-11-01

    The current status and future potential of solar-tower, parabolic-reflector/Stirling-engine, channel-collector, and photovoltaic solar power plants of capacity 10 MWe or more are discussed. Consideration is given to the geographic and technological limitations, initial investment and operating costs, presently operating facilities, market openings, and critical technological challenges controlling future expansion. Numerical data are presented in tables and graphs, and it is concluded that solar power production will soon become economically competitive. It is suggested that the channel collector, at present the most mature and cost-efficient technology, has the least potential for further improvement, and that parabolic/Stirling and photovoltaic systems are probably better suited to smaller applications than to large-scale commercial power production.

  9. EDITORIAL: Safety aspects of fusion power plants

    Science.gov (United States)

    Kolbasov, B. N.

    2007-07-01

    This special issue of Nuclear Fusion contains 13 informative papers that were initially presented at the 8th IAEA Technical Meeting on Fusion Power Plant Safety held in Vienna, Austria, 10-13 July 2006. Following recommendation from the International Fusion Research Council, the IAEA organizes Technical Meetings on Fusion Safety with the aim to bring together experts to discuss the ongoing work, share new ideas and outline general guidance and recommendations on different issues related to safety and environmental (S&E) aspects of fusion research and power facilities. Previous meetings in this series were held in Vienna, Austria (1980), Ispra, Italy (1983), Culham, UK (1986), Jackson Hole, USA (1989), Toronto, Canada (1993), Naka, Japan (1996) and Cannes, France (2000). The recognized progress in fusion research and technology over the last quarter of a century has boosted the awareness of the potential of fusion to be a practically inexhaustible and clean source of energy. The decision to construct the International Thermonuclear Experimental Reactor (ITER) represents a landmark in the path to fusion power engineering. Ongoing activities to license ITER in France look for an adequate balance between technological and scientific deliverables and complying with safety requirements. Actually, this is the first instance of licensing a representative fusion machine, and it will very likely shape the way in which a more common basis for establishing safety standards and policies for licensing future fusion power plants will be developed. Now that ITER licensing activities are underway, it is becoming clear that the international fusion community should strengthen its efforts in the area of designing the next generations of fusion power plants—demonstrational and commercial. Therefore, the 8th IAEA Technical Meeting on Fusion Safety focused on the safety aspects of power facilities. Some ITER-related safety issues were reported and discussed owing to their potential

  10. KRW oxygen-blown gasification combined cycle: Carbon dioxide recovery, transport, and disposal

    Energy Technology Data Exchange (ETDEWEB)

    Doctor, R.D.; Molburg, J.C.; Thimmapuram, P.R.

    1996-08-01

    This project emphasizes CO{sub 2}-capture technologies combined with integrated gasification combined-cycle (IGCC) power systems. Complementary evaluations address CO{sub 2} transportation, CO{sub 2} use, and options for the long-term sequestration of unused CO{sub 2}. The intent is to provide the CO{sub 2} budget, or an equivalent CO{sub 2} budget, associated with each of the individual energy-cycle steps, in addition to process design capital and operating costs. The base case is a 458-MW (gross generation) IGCC system that uses an oxygen-blown Kellogg-Rust-Westinghouse agglomerating fluidized-bed gasifier, Illinois No. 6 bituminous coal feed, and low-pressure glycol sulfur removal followed by Claus/SCOT treatment to produce a saleable product. Mining, feed preparation, and conversion result in a net electric power production for the entire energy cycle of 411 MW, with a CO{sub 2} release rate of 0.801 kg/k Whe. For comparison, in two cases, the gasifier output was taken through water-gas shift and then to low-pressure glycol H{sub 2}S recovery, followed by either low-pressure glycol or membrane CO{sub 2} recovery and then by a combustion turbine being fed a high-hydrogen-content fuel. Two additional cases employed chilled methanol for H{sub 2}S recovery and a fuel cell as the topping cycle with no shift stages. From the IGCC plant, a 500-km pipeline took the CO{sub 2} to geological sequestering. In a comparison of air-blown and oxygen-blown CO{sub 2}-release base cases, the cost of electricity for the air-blown IGCC was 56.86 mills/kWh, and the cost of oxygen-blown IGCC was 58.29 mills/kWh.

  11. Risks of potential accidents of nuclear power plants in Europe

    NARCIS (Netherlands)

    Slaper H; Eggink GJ; Blaauboer RO

    1993-01-01

    Over 200 nuclear power plants for commercial electricity production are presently operational in Europe. The 1986 accident with the nuclear power plant in Chernobyl has shown that severe accidents with a nuclear power plant can lead to a large scale contamination of Europe. This report is focussed

  12. Risks of potential accidents of nuclear power plants in Europe

    NARCIS (Netherlands)

    Slaper H; Eggink GJ; Blaauboer RO

    1993-01-01

    Over 200 nuclear power plants for commercial electricity production are presently operational in Europe. The 1986 accident with the nuclear power plant in Chernobyl has shown that severe accidents with a nuclear power plant can lead to a large scale contamination of Europe. This report is focussed o

  13. 76 FR 66089 - Access Authorization Program for Nuclear Power Plants

    Science.gov (United States)

    2011-10-25

    ... COMMISSION Access Authorization Program for Nuclear Power Plants AGENCY: Nuclear Regulatory Commission... revision to Regulatory Guide 5.66, ``Access Authorization Program for Nuclear Power Plants.'' This guide... Authorization Requirements for Nuclear Power Plants,'' and 10 CFR part 26, ``Fitness for Duty Programs.'' The......

  14. Risks of potential accidents of nuclear power plants in Europe

    NARCIS (Netherlands)

    Slaper H; Eggink GJ; Blaauboer RO

    1993-01-01

    Over 200 nuclear power plants for commercial electricity production are presently operational in Europe. The 1986 accident with the nuclear power plant in Chernobyl has shown that severe accidents with a nuclear power plant can lead to a large scale contamination of Europe. This report is focussed

  15. Wind Power Plant Voltage Stability Evaluation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  16. Goethermal power plant with Kalina cycle

    Energy Technology Data Exchange (ETDEWEB)

    Renz, M.; Filipovic, A. [M+W Zander Facility Engineering GmbH, Stuttgart (Germany). Marketing-Communications

    2005-04-01

    Several factors are creating an increased market for small power plant technology. These include the need for distributed/decentralised power systems, the need to generate more electricity by non-combustion renewable processes, the need for sustainable power for economic growth in developing countries and the deregulation and privatization of the electrical generation sector. Basically there are 2 alternate principles to improve the efficiency of the Rankine steam cycle for low temperature applications: Replacing water by a one-component fluid with lower boiling points, e.g. different organic substances like n-pentane, isobutene, perfluoropen-tane. (Organic Rankine Cycle, ORC). Replacing water by a binary working fluid like ammonia-water as proposed by Kalina. Kalina and ORC power cycles are primarily used for lower temperature heat sources, such as goethermal or waste-heat recovery. The primary advantage of this technology is the operation at low temperature which is given at renewable heat sources and waste heat. Further the power cycles are simple and generally can be operated remotely, without licensed operators, allowing for increased use of self-diagnostics. M+W Zander is working closely with partners to establish an alternative technology for geothermal applications. (orig.)

  17. Osmo-power - Theory and performance of an osmo-power pilot plant

    Science.gov (United States)

    Jellinek, H. H. G.; Masuda, H.

    A theoretical and experimental study of the production of useful energy by the natural process of osmosis is presented. Using the results of the study a conceptual design of an osmotic pilot plant is performed. The power produced by a 1.6 MW/sq km plant has a competitive cost with that produced by both fossil power plants and nuclear power plants.

  18. China’s Nuclear Power Plants in Operation

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Qinshan Plant Phase I Located in Haiyan,Zhejiang Province,Qinshan Nuclear Power Plant Phase I is t he first 300-megawatt pressurized water reactor (PWR) nuclear power plant independently designed,constructed,operated and managed by China.The plant came into commercial operation in April 1994.

  19. Energy analysis of a combined solid oxide fuel cell with a steam turbine power plant for marine applications

    Science.gov (United States)

    Welaya, Yousri M. A.; Mosleh, M.; Ammar, Nader R.

    2013-12-01

    Strong restrictions on emissions from marine power plants (particularly SO x , NO x ) will probably be adopted in the near future. In this paper, a combined solid oxide fuel cell (SOFC) and steam turbine fuelled by natural gas is proposed as an attractive option to limit the environmental impact of the marine sector. The analyzed variant of the combined cycle includes a SOFC operated with natural gas fuel and a steam turbine with a single-pressure waste heat boiler. The calculations were performed for two types of tubular and planar SOFCs, each with an output power of 18 MW. This paper includes a detailed energy analysis of the combined system. Mass and energy balances are performed not only for the whole plant but also for each component in order to evaluate the thermal efficiency of the combined cycle. In addition, the effects of using natural gas as a fuel on the fuel cell voltage and performance are investigated. It has been found that a high overall efficiency approaching 60% may be achieved with an optimum configuration using the SOFC system. The hybrid system would also reduce emissions, fuel consumption, and improve the total system efficiency.

  20. Energy Analysis of a Combined Solid Oxide Fuel Cell with a Steam Turbine Power Plant for Marine Applications

    Institute of Scientific and Technical Information of China (English)

    Yousri M. A. Welaya; M. Mosleh; Nader R. Ammar

    2013-01-01

    Strong restrictions on emissions from marine power plants (particularly SOx, NOx) will probably be adopted in the near future. In this paper, a combined solid oxide fuel cell (SOFC) and steam turbine fuelled by natural gas is proposed as an attractive option to limit the environmental impact of the marine sector. The analyzed variant of the combined cycle includes a SOFC operated with natural gas fuel and a steam turbine with a single-pressure waste heat boiler. The calculations were performed for two types of tubular and planar SOFCs, each with an output power of 18 MW. This paper includes a detailed energy analysis of the combined system. Mass and energy balances are performed not only for the whole plant but also for each component in order to evaluate the thermal efficiency of the combined cycle. In addition, the effects of using natural gas as a fuel on the fuel cell voltage and performance are investigated. It has been found that a high overall efficiency approaching 60%may be achieved with an optimum configuration using the SOFC system. The hybrid system would also reduce emissions, fuel consumption, and improve the total system efficiency.

  1. Performance Comparison on Repowering of a Steam Power Plant with Gas Turbines and Solid Oxide Fuel Cells

    Directory of Open Access Journals (Sweden)

    Masoud Rokni

    2016-05-01

    Full Text Available Repowering is a process for transforming an old power plant for greater capacity and/or higher efficiency. As a consequence, the repowered plant is characterized by higher power output and less specific CO2 emissions. Usually, repowering is performed by adding one or more gas turbines into an existing steam cycle which was built decades ago. Thus, traditional repowering results in combined cycles (CC. High temperature fuel cells (such as solid oxide fuel cell (SOFC could also be used as a topping cycle, achieving even higher global plant efficiency and even lower specific CO2 emissions. Decreasing the operating temperature in a SOFC allows the use of less complex materials and construction methods, consequently reducing plant and the electricity costs. A lower working temperature makes it also suitable for topping an existing steam cycle, instead of gas turbines. This is also the target of this study, repowering of an existing power plant with SOFC as well as gas turbines. Different repowering strategies are studied here, repowering with one gas turbine with and without supplementary firing, repowering with two gas turbines with and without supplementary firing and finally repowering using SOFC. Plant performances and CO2 emissions are compared for the suggested repowered plants.

  2. 75 FR 80547 - Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit No. 1; Exemption

    Science.gov (United States)

    2010-12-22

    ... COMMISSION Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit No. 1; Exemption 1.0... License No. NPF-63, which authorizes operation of the Shearon Harris Nuclear Power Plant (HNP), Unit 1... request to generically extend the rule's compliance date for all operating nuclear power plants, but...

  3. 75 FR 77919 - Carolina Power & Light Company Shearon Harris Nuclear Power Plant, Unit 1; Environmental...

    Science.gov (United States)

    2010-12-14

    ... COMMISSION Carolina Power & Light Company Shearon Harris Nuclear Power Plant, Unit 1; Environmental... Progress Energy Carolinas, Inc., for operation of the Shearon Harris Nuclear Power Plant (HNP), Unit 1...: Regarding Shearon Harris Nuclear Power Plant, Unit 1--Final Report (NUREG-1437, Supplement 33).''...

  4. 75 FR 9958 - Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit 1; Exemption

    Science.gov (United States)

    2010-03-04

    ... COMMISSION Carolina Power & Light Company, Shearon Harris Nuclear Power Plant, Unit 1; Exemption 1.0... of the Shearon Harris Nuclear Power Plant, Unit 1 (HNP). The license provides, among other things... operating nuclear power plants, but noted that the Commission's regulations provide mechanisms...

  5. Power, power density and efficiency optimization for a closed cycle helium turbine nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Chen Lingen E-mail: lgchenna@public.wh.hb.cn; Zheng Junlin; Sun Fengrui; Wu Chih

    2003-09-01

    The performance of a closed cycle helium turbine nuclear power plant for submarine propulsion is optimized in this paper. The power output, power density (ratio of power output to maximum specific volume in the cycle) and thermal efficiency of the cycle are derived. The maximum power, power density and efficiency are obtained by searching for the optimum heat conductance distribution among the hot side heat exchanger (intermediate heat exchanger), cold side heat exchanger (precooler) and recuperator for fixed total heat exchanger inventory with respect to the corresponding optimization objectives. The optimum results are compared with those reported in recent references for the conceptual design of a closed cycle helium turbine nuclear power plant for submarine propulsion. The numerical example shows that the method herein is valid and effective.

  6. Water treatment plants assessment at Talkha power plant.

    Science.gov (United States)

    El-Sebaie, Olfat D; Abd El-Kerim, Ghazy E; Ramadan, Mohamed H; Abd El-Atey, Magda M; Taha, Sahr Ahmed

    2002-01-01

    Talkha power plant is the only power plant located in El-Mansoura. It generates electricity using two different methods by steam turbine and gas turbine. Both plants drew water from River Nile (208 m3 /h). The Nile raw water passes through different treatment processes to be suitable for drinking and operational uses. At Talkha power plant, there are two purification plants used for drinking water supply (100 m3/h) and for water demineralization supply (108 m3/h). This study aimed at studying the efficiency of the water purification plants. For drinking water purification plant, the annual River Nile water characterized by slightly alkaline pH (7.4-8), high annual mean values of turbidity (10.06 NTU), Standard Plate Count (SPC) (313.3 CFU/1 ml), total coliform (2717/100 ml), fecal coliform (0-2400/100 ml), and total algae (3 x 10(4) org/I). The dominant group of algae all over the study period was green algae. The blue green algae was abundant in Summer and Autumn seasons. The pH range, and the annual mean values of turbidity, TDS, total hardness, sulfates, chlorides, nitrates, nitrites, fluoride, and residual chlorine for purified water were in compliance with Egyptian drinking water standards. All the SPC recorded values with an annual mean value of 10.13 CFU/1 ml indicated that chlorine dose and contact time were not enough to kill the bacteria. However, they were in compliance with Egyptian decree (should not exceed 50 CFU/1 ml). Although the removal efficiency of the plant for total coliform and blue green algae was high (98.5% and 99.2%, respectively), the limits of the obtained results with an annual mean values of 40/100 ml and 15.6 org/l were not in compliance with the Egyptian decree (should be free from total coliform, fecal coliform and blue green algae). For water demineralization treatment plant, the raw water was characterized by slightly alkaline pH. The annual mean values of conductivity, turbidity, and TDS were 354.6 microS/cm, 10.84 NTU, and 214

  7. Progress and prospects for phosphoric acid fuel cell power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bonville, L.J.; Scheffler, G.W.; Smith, M.J. [International Fuel Cells Corp., South Windsor, CT (United States)

    1996-12-31

    International Fuel Cells (IFC) has developed the fuel cell power plant as a new, on-site power generation source. IFC`s commercial fuel cell product is the 200-kW PC25{trademark} power plant. To date over 100 PC25 units have been manufactured. Fleet operating time is in excess of one million hours. Individual units of the initial power plant model, the PC25 A, have operated for more than 30,000 hours. The first model {open_quotes}C{close_quotes} power plant has over 10,000 hours of operation. The manufacturing, application and operation of this power plant fleet has established a firm base for design and technology development in terms of a clear understanding of the requirements for power plant reliability and durability. This fleet provides the benchmark against which power plant improvements must be measured.

  8. General digitalized system on nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Akagi, Katsumi; Kadohara, Hozumi; Taniguchi, Manabu [Mitsubishi Electric Corp., Tokyo (Japan)

    2000-08-01

    Hitherto, instrumentation control system in a PWR nuclear power plant has stepwisely adopted digital technology such as application of digital instrumentation control device to ordinary use (primary/secondary system control device, and so on), application of CRT display system to monitoring function, and so forth, to realize load reduction of an operator due to expansion of operation automation range, upgrading of reliability and maintenance due to self-diagnosis function, reduction of mass in cables due to multiple transfer, and upgrading of visual recognition due to information integration. In next term PWR plant instrumentation control system, under consideration of application practice of conventional digital technology, application of general digitalisation system to adopt digitalisation of overall instrumentation control system containing safety protection system, and central instrumentation system (new type of instrumentation system) and to intend to further upgrade economics, maintenance, operability/monitoring under security of reliability/safety is planned. And, together with embodiment of construction program of the next-term plant, verification at the general digitalisation proto-system aiming at establishment of basic technology on the system is carried out. Then, here was described on abstract of the general digitalisation system and characteristics of a digital type safety protection apparatus to be adopted in the next-term plant. (G.K.)

  9. Pilot plant straw biomass power plant; Demonstrationsanlage Strohkraftwerk Gronau

    Energy Technology Data Exchange (ETDEWEB)

    Vodegel, Stefan [Claustahler Umwelttechnik-Institut GmbH (CUTEC), Clausthal-Zellerfeld (Germany); Lach, Friedrich-Wilhelm [Ueberlandwerk Leinetal GmbH, Gronau (Leine) (Germany)

    2008-07-01

    Drastically increasing prices for oil and gas promote the change to renewable energies. Biomass has the advantage of the storability. However, it has the disadvantage of a small stocking density. This suggests decentralized power plants. Also the proven technology of water vapour cycles with use of turbine is questioned. In the rural district Hildesheim there are efforts of thermal utilisation straw from wheat cropping. For this, a feasibility study of the Claustahler Umwelttechnik-Technik GmbH (Clausthal Zellerfeld, Federal Republic of Germany) presents technical and economic possibilities exemplary for the industrial area West in Gronau (Federal Republic of Germany). Technical and economic chances and risks are pointed out.

  10. RBCC可重复使用运载器上升段轨迹优化设计%Since the multi-phase and multi-control-variable trajectory of the reusable launch vehicle ( RLV) which is coupled with the thrust powered by rocket based combined cycle (RBCC) is difficult to solve,the numerical optimization model and method based on Gau

    Institute of Scientific and Technical Information of China (English)

    龚春林; 韩璐

    2012-01-01

    Since the multi-phase and multi-control-variable trajectory of the reusable launch vehicle ( RLV) which is coupled with the thrust powered by rocket based combined cycle (RBCC) is difficult to solve,the numerical optimization model and method based on Gauss Pseudospectral Method (CPM) were proposed,and the optimal-fuel ascent trajectory was obtained. Hie trajectory is divided into three phases powered by rocket,ramjet and scramjet in sequence. The angle of attack and fuel flow are control variables,and according to the trajectory mission,the ignition and work condition of the each mode,the optimization model was built,the terminal and path constraints were imposed. The optimal trajectory was solved by using GPM and the boundary control variables were solved by a special method. Compared with the result by traditional method,the optimization model and GPM can solve trajectory optimization problems effectively, and the optimal result accords with the characteristic of the RBCC-powered RLV and satisfies all the constraints.%针对火箭基组合动力(RBCC)可重复使用运载器(RLV)轨迹多段、多控制变量、推力与飞行轨迹耦合,飞行轨迹设计困难的问题,提出了基于高斯伪光谱方法的数值优化求解模型和求解方法,并获得满足要求的上升段燃料最省轨迹.将该轨迹分为3部分,分别由引射火箭、亚燃冲压和超燃冲压发动机提供动力,以攻角和燃料秒流量为控制变量,根据轨迹任务和各模态发动机启动及工作条件建立优化模型、设定各段末端和路径约束,利用高斯伪谱法求解最优轨迹并利用特殊方法计算边界控制变量.通过与传统方法所得轨迹的对比表明,所建立的优化模型和方法可快速求解出RBCC运载器上升段最优轨迹,优化结果符合RBCC运载器工作特点.

  11. High-power LEDs for plant cultivation

    Science.gov (United States)

    Tamulaitis, Gintautas; Duchovskis, Pavelas; Bliznikas, Zenius; Breive, Kestutis; Ulinskaite, Raimonda; Brazaityte, Ausra; Novickovas, Algirdas; Zukauskas, Arturas; Shur, Michael S.

    2004-10-01

    We report on high-power solid-state lighting facility for cultivation of greenhouse vegetables and on the results of the study of control of photosynthetic activity and growth morphology of radish and lettuce imposed by variation of the spectral composition of illumination. Experimental lighting modules (useful area of 0.22 m2) were designed based on 4 types of high-power light-emitting diodes (LEDs) with emission peaked in red at the wavelengths of 660 nm and 640 nm (predominantly absorbed by chlorophyll a and b for photosynthesis, respectively), in blue at 455 nm (phototropic function), and in far-red at 735 nm (important for photomorphology). Morphological characteristics, chlorophyll and phytohormone concentrations in radish and lettuce grown in phytotron chambers under lighting with different spectral composition of the LED-based illuminator and under illumination by high pressure sodium lamps with an equivalent photosynthetic photon flux density were compared. A well-balanced solid-state lighting was found to enhance production of green mass and to ensure healthy morphogenesis of plants compared to those grown using conventional lighting. We observed that the plant morphology and concentrations of morphologically active phytohormones is strongly affected by the spectral composition of light in the red region. Commercial application of the LED-based illumination for large-scale plant cultivation is discussed. This technology is favorable from the point of view of energy consumption, controllable growth, and food safety but is hindered by high cost of the LEDs. Large scale manufacturing of high-power red AlInGaP-based LEDs emitting at 650 nm and a further decrease of the photon price for the LEDs emitting in the vicinity of the absorption peak of chlorophylls have to be achieved to promote horticulture applications.

  12. Exergoeconomic analysis of a nuclear power plant

    Science.gov (United States)

    Moreno, Roman Miguel

    Exergoeconomic analysis of a nuclear power plant is a focus of this dissertation. Specifically, the performance of the Palo Verde Nuclear Power Plant in Arizona is examined. The analysis combines thermodynamic second law exergy analysis with economics in order to assign costs to the loss and destruction of exergy. This work was done entirely with an interacting spreadsheets notebook. The procedures are to first determine conventional energy flow, where the thermodynamic stream state points are calculated automatically. Exergy flow is then evaluated along with destruction and losses. The capital cost and fixed investment rate used for the economics do not apply specifically to the Palo Verde Plant. Exergy costing is done next involving the solution of about 90 equations by matrix inversion. Finally, the analysis assigns cost to the exergy destruction and losses in each component. In this work, the cost of electricity (exergy), including capital cost, leaving the generator came to 38,400 /hr. The major exergy destruction occurs in the reactor where fission energy transfer is limited by the maxiμm permissible clad temperature. Exergy destruction costs were: reactor--18,207 hr, the low pressure turbine-2,000 /hr, the condenser--1,700 hr, the steam generator-1,200 $/hr. The inclusion of capital cost and O&M are important in new system design assessments. When investigating operational performance, however, these are sunk costs; only fuel cost needs to be considered. The application of a case study is included based on a real modification instituted at Palo Verde to reduce corrosion steam generator problems; the pressure in the steam generator was reduced from 1072 to 980 psi. Exergy destruction costs increased in the low pressure turbine and in the steam generator, but decreased in the reactor vessel and the condenser. The dissertation demonstrates the procedures and tools required for exergoeconomic analysis whether in the evaluation of a new nuclear reactor system

  13. Nuclear power plants for mobile applications

    Science.gov (United States)

    Anderson, J. L.

    1972-01-01

    Mobile nuclear powerplants for applications other than large ships and submarines will require compact, lightweight reactors with especially stringent impact-safety design. The technical and economic feasibility that the broadening role of civilian nuclear power, in general, (land-based nuclear electric generating plants and nuclear ships) can extend to lightweight, safe mobile nuclear powerplants are examined. The paper discusses technical experience, identifies potential sources of technology for advanced concepts, cites the results of economic studies of mobile nuclear powerplants, and surveys future technical capabilities needed by examining the current use and projected needs for vehicles, machines, and habitats that could effectively use mobile nuclear reactor powerplants.

  14. Biocorrosion in a geothermal power plant

    Energy Technology Data Exchange (ETDEWEB)

    Navarrette-Bedolla, M.; Ballesteros-Almanza, M.L.; Sanchez-Yanez, J.M. [Univ. Michoacana de San Nicolas de Hidalgo (Mexico); Valdez-Salas, B. [Univ. Autonoma de Baja California (Mexico); Hernandez-Duque, G. [Univ. del Mayab (Mexico)

    1999-04-01

    Hyperthermophilic archaebacteria (Thermoproteus neutrophilus) promoting the corrosion of type 316 stainless steel (SS) (UNS S31600) in vapor ducts of the Tejamaniles geothermal electric power plant in Los Azufres, Michoacan, Mexico, were isolated from condensed steam. Metallographic analysis and scanning electron microscopy were performed to determine the morphology of microbiological attack on the SS. Electrochemical corrosion tests showed that the bacteria induced corrosion on type 316 SS preferentially at grain boundaries. Large amounts of elemental sulfur and carbon were detected where the bacterial culture was located.

  15. Thermoeconomic optimization of the steam power plant

    Directory of Open Access Journals (Sweden)

    Reşat Selbaş, Hilmi Yazıcı, Arzu Şencan

    2010-05-01

    Full Text Available In this study, thermoeconomic optimization of the steam power plant with Levelized-cost method was carried out. Aim of thermoeconomy is to minimize exergy cost. With this aim, the first law and the second law of thermodynamics to each component of system were performed. Irreversibility and exergy values were obtained. Economic analysis by using exergy values was carried out. Unit electric cost for each component of system was calculated. Optimum design and operating conditions for minimum exergy cost were obtained.

  16. Modular stellarator reactor: a fusion power plant

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.L.; Bathke, C.G.; Krakowski, R.A.; Heck, F.M.; Green, L.; Karbowski, J.S.; Murphy, J.H.; Tupper, R.B.; DeLuca, R.A.; Moazed, A.

    1983-07-01

    A comparative analysis of the modular stellarator and the torsatron concepts is made based upon a steady-state ignited, DT-fueled, reactor embodiment of each concept for use as a central electric-power station. Parametric tradeoff calculations lead to the selection of four design points for an approx. 4-GWt plant based upon Alcator transport scaling in l = 2 systems of moderate aspect ratio. The four design points represent high-aspect ratio. The four design points represent high-(0.08) and low-(0.04) beta versions of the modular stellarator and torsatron concepts. The physics basis of each design point is described together with supporting engineering and economic analyses. The primary intent of this study is the elucidation of key physics and engineering tradeoffs, constraints, and uncertainties with respect to the ultimate power reactor embodiment.

  17. 76 FR 4391 - Calvert Cliffs Nuclear Power Plant, LLC, Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2011-01-25

    ... COMMISSION Calvert Cliffs Nuclear Power Plant, LLC, Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2; Exemption 1.0 Background Calvert Cliffs Nuclear Power Plant, LLC, the licensee, is the holder of Facility Operating License Nos. DPR-53 and DPR-69 which authorizes operation of the Calvert Cliffs Nuclear...

  18. Basic investigation on promotion of joint implementation in fiscal 2000. Efficiency improvement project for gas turbine power plant in Iran; 2000 nendo kyodo jisshi nado suishin kiso chosa hokokusho. Iran gas turbine hatsuden plant no koritsu kaizen project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Investigations and discussions have been given on measures to improve energy conservation and efficiency at a power plant of Kish Water and Power Company (KWPC) in Iran. The site has high ambient temperature throughout a year, making the gas turbine power plant capable of generating power only at about 70% of the rated output, with the power generation efficiency decreasing. The project has analyzed the current situation at the plant, and evaluated different means that appear effective in improving the efficiency, including the gas turbine absorbed air cooling system, the steam injection system, and the combined cycle. As a result of the discussions, it was revealed that energy saving effect can be obtained at 145 TJ with the gas turbine absorbed air cooling system, 224 TJ with the steam injection system, and 1017 TJ with the combined cycle. The annual reduction of greenhouse gas emission due to the above energy conservation would be about 11 thousand tons, 16.5 thousand tons, and 75 thousand tons, respectively. However, the investment payback period would be about 2.45 years, 8.31 years, and 14.21 years, respectively. Therefore, the profitability does not appear very attractive because of low fuel unit cost. (NEDO)

  19. Power plant instrumentation and control handbook a guide to thermal power plants

    CERN Document Server

    Basu, Swapan

    2014-01-01

    The book discusses instrumentation and control in modern fossil fuel power plants, with an emphasis on selecting the most appropriate systems subject to constraints engineers have for their projects. It provides all the plant process and design details, including specification sheets and standards currently followed in the plant. Among the unique features of the book are the inclusion of control loop strategies and BMS/FSSS step by step logic, coverage of analytical instruments and technologies for pollution and energy savings, and coverage of the trends toward filed bus systems and integratio

  20. Power Ramp Limitation capabilities of Large PV Power Plants with Active Power Reserves

    DEFF Research Database (Denmark)

    Bogdan, Craciun; Kerekes, Tamas; Sera, Dezso

    2017-01-01

    Power Ramp Limitation (PRL) is likely to become a requirement for large scale photovoltaic power plants (LPVPPs) in order to allow the increase of PV penetration levels. Especially in islands with reduced inertia capability, this problem is more stringent: high power ramp can be caused by either...... fast irradiance changes or other participant generators for example wind power, or loads. In order to compensate for the power mismatch, LPVPPs must use Active Power Reserve (APR), by either curtailment or auxiliary storage. The paper proposes a PRL control structure for dynamic APR sizing...... area of LPVPPs acts as filter against fast irradiance changes, the study reveals also the required plant size for which auxiliary storage is no longer needed in order to comply with PRL requirements – an important economical aspect....

  1. BOILER MATERIALS FOR ULTRASUPERCRITICAL COAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    R. Viswanathan; K. Coleman

    2002-10-15

    The principal objective of this project is to develop materials technology for use in ultrasupercritical (USC) plant boilers capable of operating with 760 C (1400 F), 35 MPa (5000 psi) steam. In the 21st century, the world faces the critical challenge of providing abundant, cheap electricity to meet the needs of a growing global population while at the same time preserving environmental values. Most studies of this issue conclude that a robust portfolio of generation technologies and fuels should be developed to assure that the United States will have adequate electricity supplies in a variety of possible future scenarios. The use of coal for electricity generation poses a unique set of challenges. On the one hand, coal is plentiful and available at low cost in much of the world, notably in the U.S., China, and India. Countries with large coal reserves will want to develop them to foster economic growth and energy security. On the other hand, traditional methods of coal combustion emit pollutants and CO{sub 2} at high levels relative to other generation options. Maintaining coal as a generation option in the 21st century will require methods for addressing these environmental issues. This project has established a government/industry consortium to undertake a five-year effort to evaluate and develop of advanced materials that allow the use of advanced steam cycles in coal-based power plants. These advanced cycles, with steam temperatures up to 760 C, will increase the efficiency of coal-fired boilers from an average of 35% efficiency (current domestic fleet) to 47% (HHV). This efficiency increase will enable coal-fired power plants to generate electricity at competitive rates (irrespective of fuel costs) while reducing CO{sub 2} and other fuel-related emissions by as much as 29%. Success in achieving these objectives will support a number of broader goals. First, from a national prospective, the program will identify advanced materials that will make it possible to

  2. BOILER MATERIALS FOR ULTRASUPERCRITICAL COAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    R. Viswanathan; K. Coleman

    2003-01-20

    The principal objective of this project is to develop materials technology for use in ultrasupercritical (USC) plant boilers capable of operating with 760 C (1400 F), 35 MPa (5000 psi) steam. In the 21st century, the world faces the critical challenge of providing abundant, cheap electricity to meet the needs of a growing global population while at the same time preserving environmental values. Most studies of this issue conclude that a robust portfolio of generation technologies and fuels should be developed to assure that the United States will have adequate electricity supplies in a variety of possible future scenarios. The use of coal for electricity generation poses a unique set of challenges. On the one hand, coal is plentiful and available at low cost in much of the world, notably in the U.S., China, and India. Countries with large coal reserves will want to develop them to foster economic growth and energy security. On the other hand, traditional methods of coal combustion emit pollutants and CO{sub 2} at high levels relative to other generation options. Maintaining coal as a generation option in the 21st century will require methods for addressing these environmental issues. This project has established a government/industry consortium to undertake a five-year effort to evaluate and develop of advanced materials that allow the use of advanced steam cycles in coal-based power plants. These advanced cycles, with steam temperatures up to 760 C, will increase the efficiency of coal-fired boilers from an average of 35% efficiency (current domestic fleet) to 47% (HHV). This efficiency increase will enable coal-fired power plants to generate electricity at competitive rates (irrespective of fuel costs) while reducing CO{sub 2} and other fuel-related emissions by as much as 29%. Success in achieving these objectives will support a number of broader goals. First, from a national prospective, the program will identify advanced materials that will make it possible to

  3. BOILER MATERIALS FOR ULTRASUPERCRITICAL COAL POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    R. Viswanathan

    2002-04-15

    The principal objective of this project is to develop materials technology for use in ultrasupercritical (USC) plant boilers capable of operating with 760 C (1400 F), and up to 5500 psi with emphasis upon 35 MPa (5000 psi) steam. In the 21st century, the world faces the critical challenge of providing abundant, cheap electricity to meet the needs of a growing global population while at the same time preserving environmental values. Most studies of this issue conclude that a robust portfolio of generation technologies and fuels should be developed to assure that the United States will have adequate electricity supplies in a variety of possible future scenarios. The use of coal for electricity generation poses a unique set of challenges. On the one hand, coal is plentiful and available at low cost in much of the world, notably in the U.S., China, and India. Countries with large coal reserves will want to develop them to foster economic growth and energy security. On the other hand, traditional methods of coal combustion emit pollutants and CO{sub 2} at high levels relative to other generation options. Maintaining coal as a generation option in the 21st century will require methods for addressing these environmental issues. This project has established a government/industry consortium to undertake a five-year effort to evaluate and develop advanced materials that allow the use of advanced steam cycles in coal-based power plants. These advanced cycles, with steam temperatures up to 760 C, will increase the efficiency of coal-fired boilers from an average of 35% efficiency (current domestic fleet) to 47% (HHV). This efficiency increase will enable coal-fired power plants to generate electricity at competitive rates (irrespective of fuel costs) while reducing CO{sub 2} and other fuel-related emissions by as much as 29%. Success in achieving these objectives will support a number of broader goals. First, from a national prospective, the program will identify advanced

  4. Hydraulic Power Plant Machine Dynamic Diagnosis

    Directory of Open Access Journals (Sweden)

    Hans Günther Poll

    2006-01-01

    Full Text Available A method how to perform an entire structural and hydraulic diagnosis of prototype Francis power machines is presented and discussed in this report. Machine diagnosis of Francis units consists on a proper evaluation of acquired mechanical, thermal and hydraulic data obtained in different operating conditions of several rotary and non rotary machine components. Many different physical quantities of a Francis machine such as pressure, strains, vibration related data, water flow, air flow, position of regulating devices and displacements are measured in a synchronized way so that a relation of cause an effect can be developed for each operating condition and help one to understand all phenomena that are involved with such kind of machine. This amount of data needs to be adequately post processed in order to allow correct interpretation of the machine dynamics and finally these data must be compared with the expected calculated data not only to fine tuning the calculation methods but also to accomplish fully understanding of the influence of the water passages on such machines. The way how the power plant owner has to operate its Francis machines, many times also determined by a central dispatcher, has a high influence on the fatigue life time of the machine components. The diagnostic method presented in this report helps one to understand the importance of adequate operation to allow a low maintenance cost for the entire power plant. The method how to acquire these quantities is discussed in details together with the importance of correct sensor balancing, calibration and adequate correlation with the physical quantities. Typical results of the dynamic machine behavior, with adequate interpretation, obtained in recent measurement campaigns of some important hydraulic turbines were presented. The paper highlights the investigation focus of the hydraulic machine behavior and how to tailor the measurement strategy to accomplish all goals. Finally some

  5. Nuclear power plant Severe Accident Research Plan

    Energy Technology Data Exchange (ETDEWEB)

    Larkins, J T; Cunningham, M A

    1983-01-01

    The Severe Accident Research Plan (SARP) will provide technical information necessary to support regulatory decisions in the severe accident area for existing or planned nuclear power plants, and covers research for the time period of January 1982 through January 1986. SARP will develop generic bases to determine how safe the plants are and where and how their level of safety ought to be improved. The analysis to address these issues will be performed using improved probabilistic risk assessment methodology, as benchmarked to more exact data and analysis. There are thirteen program elements in the plan and the work is phased in two parts, with the first phase being completed in early 1984, at which time an assessment will be made whether or not any major changes will be recommended to the Commission for operating plants to handle severe accidents. Additionally at this time, all of the thirteen program elements in Chapter 5 will be reviewed and assessed in terms of how much additional work is necessary and where major impacts in probabilistic risk assessment might be achieved. Confirmatory research will be carried out in phase II to provide additional assurance on the appropriateness of phase I decisions. Most of this work will be concluded by early 1986.

  6. Overview of the Turbine Based Combined Cycle Discipline

    Science.gov (United States)

    Thomas, Scott R.; Walker, James F.; Pittman, James L.

    2009-01-01

    The NASA Fundamental Aeronautics Hypersonics project is focused on technologies for combined cycle, airbreathing propulsions systems to enable reusable launch systems for access to space. Turbine Based Combined Cycle (TBCC) propulsion systems offer specific impulse (Isp) improvements over rocket-based propulsion systems in the subsonic takeoff and return mission segments and offer improved safety. The potential to realize more aircraft-like operations with expanded launch site capability and reduced system maintenance are additional benefits. The most critical TBCC enabling technologies as identified in the National Aeronautics Institute (NAI) study were: 1) mode transition from the low speed propulsion system to the high speed propulsion system, 2) high Mach turbine engine development, 3) transonic aero-propulsion performance, 4) low-Mach-number dual-mode scramjet operation, 5) innovative 3-D flowpath concepts and 6) innovative turbine based combined cycle integration. To address several of these key TBCC challenges, NASA s Hypersonics project (TBCC Discipline) initiated an experimental mode transition task that includes an analytic research endeavor to assess the state-of-the-art of propulsion system performance and design codes. This initiative includes inlet fluid and turbine performance codes and engineering-level algorithms. This effort has been focused on the Combined Cycle Engine Large-Scale Inlet Mode Transition Experiment (CCE LIMX) which is a fully integrated TBCC propulsion system with flow path sizing consistent with previous NASA and DoD proposed Hypersonic experimental flight test plans. This experiment is being tested in the NASA-GRC 10 x 10 Supersonic Wind Tunnel (SWT) Facility. The goal of this activity is to address key hypersonic combined-cycle-engine issues: (1) dual integrated inlet operability and performance issues unstart constraints, distortion constraints, bleed requirements, controls, and operability margins, (2) mode

  7. Health effects and related standards for fossil-fuel and geothermal power plants. Volume 6 of health and safety impacts of nuclear, geothermal, and fossil-fuel electric generation in California. [In California

    Energy Technology Data Exchange (ETDEWEB)

    Case, G.D.; Bertolli, T.A.; Bodington, J.C.; Choy, T.A.; Nero, A.V.

    1977-01-01

    This report reviews health effects and related standards for fossil-fuel and geothermal power plants, emphasizing impacts which may occur through emissions into the atmosphere, and treating other impacts briefly. Federal regulations as well as California state and local regulations are reviewed. Emissions are characterized by power plant type, including: coal-fired, oil-fired, gas-fired, combined cycle and advanced fossil-fuel plants; and liquid and vapor geothermal systems. Dispersion and transformation of emissions are treated. The state of knowledge of health effects, based on epidemiological, physiological, and biomedical studies, is reviewed.

  8. Operating experience with nuclear power plants 2015. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2016-07-01

    The VGB Technical Committee ''Nuclear Plant Operation'' has been exchanging operating experience about nuclear power plants for more than 30 years. Plant operators from several European countries are participating in the exchange. A report is given on the operating results achieved in 2015, events important to plant safety, special and relevant repair, and retrofit measures from Germany. The second part of this report will focus on nuclear power plant in Belgium, Finland, the Netherlands, Switzerland, and Spain.

  9. Fukushima nuclear power plant accident was preventable

    Science.gov (United States)

    Kanoglu, Utku; Synolakis, Costas

    2015-04-01

    On 11 March 2011, the fourth largest earthquake in recorded history triggered a large tsunami, which will probably be remembered from the dramatic live pictures in a country, which is possibly the most tsunami-prepared in the world. The earthquake and tsunami caused a major nuclear power plant (NPP) accident at the Fukushima Dai-ichi, owned by Tokyo Electric Power Company (TEPCO). The accident was likely more severe than the 1979 Three Mile Island and less severe than the Chernobyl 1986 accidents. Yet, after the 26 December 2004 Indian Ocean tsunami had hit the Madras Atomic Power Station there had been renewed interest in the resilience of NPPs to tsunamis. The 11 March 2011 tsunami hit the Onagawa, Fukushima Dai-ichi, Fukushima Dai-ni, and Tokai Dai-ni NPPs, all located approximately in a 230km stretch along the east coast of Honshu. The Onagawa NPP was the closest to the source and was hit by an approximately height of 13m tsunami, of the same height as the one that hit the Fukushima Dai-ichi. Even though the Onagawa site also subsided by 1m, the tsunami did not reach to the main critical facilities. As the International Atomic Energy Agency put it, the Onagawa NPP survived the event "remarkably undamaged." At Fukushima Dai-ichi, the three reactors in operation were shut down due to strong ground shaking. The earthquake damaged all offsite electric transmission facilities. Emergency diesel generators (EDGs) provided back up power and started cooling down the reactors. However, the tsunami flooded the facilities damaging 12 of its 13 EDGs and caused a blackout. Among the consequences were hydrogen explosions that released radioactive material in the environment. It is unfortunately clear that TEPCO and Japan's principal regulator Nuclear and Industrial Safety Agency (NISA) had failed in providing a professional hazard analysis for the plant, even though their last assessment had taken place only months before the accident. The main reasons are the following. One

  10. Storing carbon dioxide in saline formations : analyzing extracted water treatment and use for power plant cooling.

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, Brian P.; Heath, Jason E.; Borns, David James; Dewers, Thomas A.; Kobos, Peter Holmes; Roach, Jesse D.; McNemar, Andrea; Krumhansl, James Lee; Klise, Geoffrey T.

    2010-10-01

    system) constraints across the United States. Finally, a representative scenario for a 1,800 MW subcritical coal fired power plant (amongst other types including supercritical coal, integrated gasification combined cycle, natural gas turbine and natural gas combined cycle) can look to existing and new carbon capture, transportation, compression and sequestration technologies along with a suite of extracting and treating technologies for water to assess the system's overall physical and economic viability. Thus, this particular plant, with 90% capture, will reduce the net emissions of CO{sub 2} (original less the amount of energy and hence CO{sub 2} emissions required to power the carbon capture water treatment systems) less than 90%, and its water demands will increase by approximately 50%. These systems may increase the plant's LCOE by approximately 50% or more. This representative example suggests that scaling up these CO{sub 2} capture and sequestration technologies to many plants throughout the country could increase the water demands substantially at the regional, and possibly national level. These scenarios for all power plants and saline formations throughout U.S. can incorporate new information as it becomes available for potential new plant build out planning.

  11. First geothermal pilot power plant in Hungary

    Directory of Open Access Journals (Sweden)

    Tóth Anikó

    2007-01-01

    Full Text Available The Hungarian petroleum industry has always participated in the utilization of favourable geothermal conditions in the country. Most of the Hungarian geothermal wells were drilled by the MOL Ltd. as CH prospect holes. Accordingly, the field of geothermics belonged to the petroleum engineering, although marginally. It was therefore a surprise to hear of the decision of MOL Ltd. to build a geothermal power plant of about 2-5 MW. The tender was published in 2004.The site selected for the geothermal project is near the western border of an Hungarian oilfield, close to the Slovenian border. The location of the planned geothermal power plant was chosen after an analysis of suitable wells owned by the MOL Rt. The decision was made on the bases of different reservoir data. The existence of a reservoir of the necessary size, temperature, permeability, productivity and the water chemistry data was proved. The wells provide an enough information to understand the character of the reservoir and will be the production wells used by the planned power plant.The depth of the wells is about 2930 - 3200 m. The Triassic formation is reached at around 2851 m. The production and the reinjection wells are planned. The primary objective of the evaluation is to further learn the nature of the geothermal system. First a one-day discharge test is carried out. If this short-term test is successful, a six-months long-term discharge test will follow. The first period of the test is a transient phenomenon. Within the well test, the wellhead pressure, the flow rate, the outflowing water temperature, the dynamic fluid level, and the chemical components will be measured. The heat transfer around the bore-hole is influenced by the flow rate and the time. For the right appreciation of the measured data, it is very important to analyse the heat transfer processes around the bore-hole. The obtained data from the experiments must be also fitted into the framework of a mathematical

  12. 75 FR 3942 - Carolina Power & Light Company Shearon Harris Nuclear Power Plant, Unit 1 Environmental...

    Science.gov (United States)

    2010-01-25

    ... COMMISSION Carolina Power & Light Company Shearon Harris Nuclear Power Plant, Unit 1 Environmental Assessment...), for operation of the Shearon Harris Nuclear Power Plant, Unit 1 (HNP), located in New Hill, North... Environmental Impact Statement for License Renewal of Nuclear Plants: Regarding Shearon Harris Nuclear......

  13. Designing a power plant with highest efficiency: results from SFB 561

    Institute of Scientific and Technical Information of China (English)

    Dieter Bohn

    2009-01-01

    The goal of Collaborative Research Centre (SFB) 561 "thermally highly loaded, porous and cooled multi-layer systems for combined cycle power plants" is to expand the current technological and scientific knowledge on power plants in order to achieve total efficiencies of 65% in a combined cycle power plant in the year 2025. Therefore, the aero-thermomechanical, structural-mechanical, materials' scientific and production fundamentals for the development of steam and gas turbine components that are able to withstand highest thermal loads are being worked out within this SFB. This means for the gas turbine that combustion chamber outlet temperatures of 1520℃ at 1.7MPa are to be attained. In order to control these high temperatures, it is not only required to develop new materials' solutions, including thermal barrier coatings, but also to apply improved cooling techniques, as for example effusion cooling. This novel cooling concept is to be realised through open-porous structures. These structures can consist of drilled open-porous multi-layer systems or open-porous metallic foams. The development of graded multi-layer systems is also extremely important, as the grading will enable the use of coolant in dependence of the requirements. The live steam parameters in the high pressure turbine are expected to be increased up to approximately 700℃ with pressure of 30MPa. These elevated steam parameters can be encountered with Ni-base alloys, but this is a costly alternative, associated with many manufacturing difficulties. Therefore, the SFB proposes cooling the highly loaded turbines instead, as this would necessitate the application of far less Ni-base alloys. To protect the thermally highly loaded casing, a sandwich material consisting of two thin face sheets with a core of a woven wire mesh is used to cover the walls of the steam turbine casing.The current state of the research shows that by utilising innovative cooling technologies a total efficiency of 65% can be

  14. Optimal dispatch strategy for the agile virtual power plant

    DEFF Research Database (Denmark)

    Petersen, Mette Højgaard; Bendtsen, Jan Dimon; Stoustrup, Jakob

    2012-01-01

    of perfect prediction is unrealistic. This paper therefore introduces the Agile Virtual Power Plant. The Agile Virtual Power Plant assumes that the base load production planning based on best available knowledge is already given, so imbalances cannot be predicted. Consequently the Agile Virtual Power Plant...... attempts to preserve maneuverability (stay agile) rather than optimize performance according to predictions. In this paper the imbalance compensation problem for an Agile Virtual Power Plant is formulated. It is proved formally, that when local units are power and energy constrained integrators a dispatch...

  15. Armatures in thermal power plants; Armaturen in Waermekraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Wiesner, Thomas; Moenning, Wolfgang (eds.)

    2011-07-01

    The book includes contributions on the following issues: (1) Fundamentals: Stop valves - minimal power loss due to full transmission. Safety valves - reliable overpressure protection. Indispensible feature of thermal power plant safety systems: the turbine bypass station. Condensate drain - safe discharge of harmful condensate. Safety armatures for gas consumption facilities. Electric actuators - automation of almost all armatures in power plants. (2) Case studies: Drainage armatures for power plant use. Steam cooling and saturation in thermal power plants - established techniques and solutions. Isolation flap for cooling water systems. Regulatory requirements and their practical implementation.

  16. Operating results 2015. Nuclear power plants. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2016-05-15

    A report is given on the opening results achieved in 2015, events important to plant safety, special and relevant repair, and retrofit measures from nuclear power plants in Germany. Reports about nuclear power plants in Belgium, Finland, the Netherlands, Switzerland, and Spain will be published in further issue.

  17. Analysis of thermodynamics of two-fuel power unit integrated with a carbon dioxide separation plant

    Directory of Open Access Journals (Sweden)

    Kotowicz Janusz

    2014-12-01

    Full Text Available The article presents the results of thermodynamic analysis of the supercritical coal-fired power plant with gross electrical output of 900 MW and a pulverized coal boiler. This unit is integrated with the absorption-based CO2 separation installation. The heat required for carrying out the desorption process, is supplied by the system with the gas turbine. Analyses were performed for two variants of the system. In the first case, in addition to the gas turbine there is an evaporator powered by exhaust gases from the gas turbine expander. The second expanded variant assumes the application of gas turbine combined cycle with heat recovery steam generator and backpressure steam turbine. The way of determining the efficiency of electricity generation and other defined indicators to assess the energy performance of the test block was showed. The size of the gas turbine system was chosen because of the need for heat for the desorption unit, taking the value of the heat demand 4 MJ/kg CO2. The analysis results obtained for the both variants of the installation with integrated CO2 separation plant were compared with the results of the analysis of the block where the separation is not conducted.

  18. Analysis of thermodynamics of two-fuel power unit integrated with a carbon dioxide separation plant

    Science.gov (United States)

    Kotowicz, Janusz; Bartela, Łukasz; Mikosz, Dorota

    2014-12-01

    The article presents the results of thermodynamic analysis of the supercritical coal-fired power plant with gross electrical output of 900 MW and a pulverized coal boiler. This unit is integrated with the absorption-based CO2 separation installation. The heat required for carrying out the desorption process, is supplied by the system with the gas turbine. Analyses were performed for two variants of the system. In the first case, in addition to the gas turbine there is an evaporator powered by exhaust gases from the gas turbine expander. The second expanded variant assumes the application of gas turbine combined cycle with heat recovery steam generator and backpressure steam turbine. The way of determining the efficiency of electricity generation and other defined indicators to assess the energy performance of the test block was showed. The size of the gas turbine system was chosen because of the need for heat for the desorption unit, taking the value of the heat demand 4 MJ/kg CO2. The analysis results obtained for the both variants of the installation with integrated CO2 separation plant were compared with the results of the analysis of the block where the separation is not conducted.

  19. Affective imagery and acceptance of replacing nuclear power plants.

    Science.gov (United States)

    Keller, Carmen; Visschers, Vivianne; Siegrist, Michael

    2012-03-01

    This study examined the relationship between the content of spontaneous associations with nuclear power plants and the acceptance of using new-generation nuclear power plants to replace old ones. The study also considered gender as a variable. A representative sample of the German- and French-speaking population of Switzerland (N= 1,221) was used. Log-linear models revealed significant two-way interactions between the association content and acceptance, association content and gender, and gender and acceptance. Correspondence analysis revealed that participants who were opposed to nuclear power plants mainly associated nuclear power plants with risk, negative feelings, accidents, radioactivity, waste disposal, military use, and negative consequences for health and environment; whereas participants favoring nuclear power plants mainly associated them with energy, appearance descriptions of nuclear power plants, and necessity. Thus, individuals opposing nuclear power plants had both more concrete and more diverse associations with them than people who were in favor of nuclear power plants. In addition, participants who were undecided often mentioned similar associations to those participants who were in favor. Males more often expressed associations with energy, waste disposal, and negative health effects. Females more often made associations with appearance descriptions, negative feelings, and negative environmental effects. The results further suggest that acceptance of replacing nuclear power plants was higher in the German-speaking part of the country, where all of the Swiss nuclear power plants are physically located. Practical implications for risk communication are discussed.

  20. Using Service Oriented Architecture in a Generic Virtual Power Plant

    DEFF Research Database (Denmark)

    Andersen, Peter Bach; Poulsen, Bjarne; Træholt, Chresten;

    2009-01-01

    interesting properties that can influence the future shape of power markets. The concept holds many promises including cheaper power to the consumer, a more flexible and responsive power production and the support of a more environment-friendly development. In order to realize a software solution supporting...... the Generic Virtual Power Plant, an array of different software design principles, patterns and architectures must be applied. Especially Service Oriented Architecture (SOA) can aid in implementing the Generic Virtual Power Plant....

  1. NOVEL GAS CLEANING/CONDITIONING FOR INTEGRATED GASIFICATION COMBINED CYCLE

    Energy Technology Data Exchange (ETDEWEB)

    Dennis A. Horazak; Richard A. Newby; Eugene E. Smeltzer; Rachid B. Slimane; P. Vann Bush; James L. Aderhold Jr; Bruce G. Bryan

    2005-12-01

    Development efforts have been underway for decades to replace dry-gas cleaning technology with humid-gas cleaning technology that would maintain the water vapor content in the raw gas by conducting cleaning at sufficiently high temperature to avoid water vapor condensation and would thus significantly simplify the plant and improve its thermal efficiency. Siemens Power Generation, Inc. conducted a program with the Gas Technology Institute (GTI) to develop a Novel Gas Cleaning process that uses a new type of gas-sorbent contactor, the ''filter-reactor''. The Filter-Reactor Novel Gas Cleaning process described and evaluated here is in its early stages of development and this evaluation is classified as conceptual. The commercial evaluations have been coupled with integrated Process Development Unit testing performed at a GTI coal gasifier test facility to demonstrate, at sub-scale the process performance capabilities. The commercial evaluations and Process Development Unit test results are presented in Volumes 1 and 2 of this report, respectively. Two gas cleaning applications with significantly differing gas cleaning requirements were considered in the evaluation: IGCC power generation, and Methanol Synthesis with electric power co-production. For the IGCC power generation application, two sets of gas cleaning requirements were applied, one representing the most stringent ''current'' gas cleaning requirements, and a second set representing possible, very stringent ''future'' gas cleaning requirements. Current gas cleaning requirements were used for Methanol Synthesis in the evaluation because these cleaning requirements represent the most stringent of cleaning requirements and the most challenging for the Filter-Reactor Novel Gas Cleaning process. The scope of the evaluation for each application was: (1) Select the configuration for the Filter-Reactor Novel Gas Cleaning Process, the arrangement of the

  2. Pressurized fluidized-bed power stations. Combined cycle power plants with fluidized-bed combustion, with particular regard to emissions; Druckwirbelschicht-Kraftwerke. Kombikraftwerke mit Druckwirbelschichtfeuerung - Entwicklung fuer Braunkohle unter besonderer Beruecksichtigung des Emissionsverhaltens

    Energy Technology Data Exchange (ETDEWEB)

    Chalupnik, R.W.

    1999-07-01

    Investigations were carried out to find whether this technology is suited for lignite. The state of the art of the pressurized fluidized bed technology for coal is presented. The planning of the experimental programme is explained, including unresolved problems of thermal calculation, raw lignite transport characteristics, and emissions. Emissions of atmospheric and pressurized fluidized bed combustion of coal and lignite are compared, and the results of a theoretical investigation of the potential performance are presented. Recommendations are made for further studies, and an outlook is given to future 'second generation' concepts with higher efficiencies resulting from higher gas turbine inlet temperatures. [German] Die vorliegende Arbeit berichtet ueber die Entwicklung der Kombikraftwerkstechnik mit Druckwirbelschichttechnik. Nachdem die bisherigen Aktivitaeten weltweit fast ausschliesslich fuer den Einsatz von Steinkohle betrieben wurden, bestand die Aufgabenstellung in der Erarbeitung von ersten grundlegenden Ergebnissen, aufgrund derer zu beurteilen war, ob die Druckwirbelschichttechnik fuer den Einsatz von Braunkohle geeignet ist. Kapitel 2 stellt den Stand der Technik der Druckwirbelschichtverbrennung fuer Steinkohle dar. In Kapitel 3 wird die Planung des Versuchsprogramms erlaeutert, die sich an den offenen Fragestellungen zu den waermetechnischen Rechnungen, zum Foerderverhalten von Rohbraunkohle und zum Emissionsverhalten orientierte. In der Diskussion der Ergebnisse in Kapitel 4 erfolgt eine Einordnung und Bewertung der ermittelten Emissionswerte im Vergleich zur Wirbelschichtverbrennung unter atmosphaerischen und druckaufgeladenen Bedingungen von Stein- und Braunkohle. In Kapitel 5 schliesslich werden die Ergebnisse einer durchgefuehrten theoretischen Untersuchung zur Ermittlung des Wirkungsgradpotentials dargestellt. Ferner werden Empfehlungen fuer ergaenzende, weiterfuehrende Untersuchungen gegeben. Fuer die langfristige potentielle Weiterentwicklung der Druckwirbelschichtfeuerung erfolgt ein Ausblick auf ein moegliches Konzept von 'second generation'-Konzepten, deren Zielsetzung eine Wirkungsgradsteigerung durch Anhebung der Gasturbineneintrittstemperatur ist. (orig.)

  3. Seismic analysis of nuclear power plant structures

    Science.gov (United States)

    Go, J. C.

    1973-01-01

    Primary structures for nuclear power plants are designed to resist expected earthquakes of the site. Two intensities are referred to as Operating Basis Earthquake and Design Basis Earthquake. These structures are required to accommodate these seismic loadings without loss of their functional integrity. Thus, no plastic yield is allowed. The application of NASTRAN in analyzing some of these seismic induced structural dynamic problems is described. NASTRAN, with some modifications, can be used to analyze most structures that are subjected to seismic loads. A brief review of the formulation of seismic-induced structural dynamics is also presented. Two typical structural problems were selected to illustrate the application of the various methods of seismic structural analysis by the NASTRAN system.

  4. Hydrogen embrittlement in power plant steels

    Indian Academy of Sciences (India)

    R K Dayal; N Parvathavarthini

    2003-06-01

    In power plants, several major components such as steam generator tubes, boilers, steam/water pipe lines, water box of condensers and the other auxiliary components like bolts, nuts, screws fasteners and supporting assemblies are commonly fabricated from plain carbon steels, as well as low and high alloy steels. These components often fail catastrophically due to hydrogen embrittlement. A brief overview of our current understanding of the phenomenon of such hydrogen damage in steels is presented in this paper. Case histories of failures of steel components due to hydrogen embrittlement, which are reported in literature, are briefly discussed. A phenomenological assessment of overall process of hydrogen embrittlement and classification of the various damage modes are summarized. Influence of several physical and metallurgical variables on the susceptibility of steels to hydrogen embrittlement, mechanisms of hydrogen embrittlement and current approaches to combat this problem are also presented.

  5. The fourth nuclear power plant in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Nogarin, Mauro

    2017-01-15

    Since 2006 the nuclear sector in Argentina has aimed at recovering and strengthening its capabilities and facilities. Part of the challenge posed by this revival has been to also accompany the development of activities with a higher level of responsibility for safety and the environment. Among the strategic decisions taken in recent years, one main highlight is the construction of the nuclear power plant CAREM25 entirely with Argentine technology and design under the responsibility of the National Atomic Energy Commission. On February 4, 2015, the Ministry of Federal Planning and the National Energy Administration (NEA) signed the agreement for cooperation and construction of pressurized water reactor (PWR) with ACP-1000 technology, developed in the Peoples Republic of China.

  6. Detecting Cyber Attacks On Nuclear Power Plants

    Science.gov (United States)

    Rrushi, Julian; Campbell, Roy

    This paper proposes an unconventional anomaly detection approach that provides digital instrumentation and control (I&C) systems in a nuclear power plant (NPP) with the capability to probabilistically discern between legitimate protocol frames and attack frames. The stochastic activity network (SAN) formalism is used to model the fusion of protocol activity in each digital I&C system and the operation of physical components of an NPP. SAN models are employed to analyze links between protocol frames as streams of bytes, their semantics in terms of NPP operations, control data as stored in the memory of I&C systems, the operations of I&C systems on NPP components, and NPP processes. Reward rates and impulse rewards are defined in the SAN models based on the activity-marking reward structure to estimate NPP operation profiles. These profiles are then used to probabilistically estimate the legitimacy of the semantics and payloads of protocol frames received by I&C systems.

  7. Optical study of solar tower power plants

    Science.gov (United States)

    Eddhibi, F.; Ben Amara, M.; Balghouthi, M.; Guizani, A.

    2015-04-01

    The central receiver technology for electricity generation consists of concentrating solar radiation coming from the solar tracker field into a central receiver surface located on the top of the tower. The heliostat field is constituted of a big number of reflective mirrors; each heliostat tracks the sun individually and reflects the sunlight to a focal point. Therefore, the heliostat should be positioned with high precision in order to minimize optical losses. In the current work, a mathematical model for the analysis of the optical efficiency of solar tower field power plant is proposed. The impact of the different factors which influence the optical efficiency is analyzed. These parameters are mainly, the shading and blocking losses, the cosine effect, the atmospheric attenuation and the spillage losses. A new method for the calculation of blocking and shadowing efficiency is introduced and validated by open literature.

  8. Emotional consequences of nuclear power plant disasters.

    Science.gov (United States)

    Bromet, Evelyn J

    2014-02-01

    The emotional consequences of nuclear power plant disasters include depression, anxiety, post-traumatic stress disorder, and medically unexplained somatic symptoms. These effects are often long term and associated with fears about developing cancer. Research on disasters involving radiation, particularly evidence from Chernobyl, indicates that mothers of young children and cleanup workers are the highest risk groups. The emotional consequences occur independently of the actual exposure received. In contrast, studies of children raised in the shadows of the Three Mile Island (TMI) and Chernobyl accidents suggest that although their self-rated health is less satisfactory than that of their peers, their emotional, academic, and psychosocial development is comparable. The importance of the psychological impact is underscored by its chronicity and by several studies showing that poor mental health is associated with physical health conditions, early mortality, disability, and overuse of medical services. Given the established increase in mental health problems following TMI and Chernobyl, it is likely that the same pattern will occur in residents and evacuees affected by the Fukushima meltdowns. Preliminary data from Fukushima indeed suggest that workers and mothers of young children are at risk of depression, anxiety, psychosomatic, and post-traumatic symptoms both as a direct result of their fears about radiation exposure and an indirect result of societal stigma. Thus, it is important that non-mental health providers learn to recognize and manage psychological symptoms and that medical programs be designed to reduce stigma and alleviate psychological suffering by integrating psychiatric and medical treatment within the walls of their clinics.Introduction of Emotional Consequences of Nuclear Power Plant Disasters (Video 2:15, http://links.lww.com/HP/A34).

  9. Autonomous Control of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Basher, H.

    2003-10-20

    A nuclear reactor is a complex system that requires highly sophisticated controllers to ensure that desired performance and safety can be achieved and maintained during its operations. Higher-demanding operational requirements such as reliability, lower environmental impacts, and improved performance under adverse conditions in nuclear power plants, coupled with the complexity and uncertainty of the models, necessitate the use of an increased level of autonomy in the control methods. In the opinion of many researchers, the tasks involved during nuclear reactor design and operation (e.g., design optimization, transient diagnosis, and core reload optimization) involve important human cognition and decisions that may be more easily achieved with intelligent methods such as expert systems, fuzzy logic, neural networks, and genetic algorithms. Many experts in the field of control systems share the idea that a higher degree of autonomy in control of complex systems such as nuclear plants is more easily achievable through the integration of conventional control systems and the intelligent components. Researchers have investigated the feasibility of the integration of fuzzy logic, neural networks, genetic algorithms, and expert systems with the conventional control methods to achieve higher degrees of autonomy in different aspects of reactor operations such as reactor startup, shutdown in emergency situations, fault detection and diagnosis, nuclear reactor alarm processing and diagnosis, and reactor load-following operations, to name a few. With the advancement of new technologies and computing power, it is feasible to automate most of the nuclear reactor control and operation, which will result in increased safety and economical benefits. This study surveys current status, practices, and recent advances made towards developing autonomous control systems for nuclear reactors.

  10. Technologies for coal based hydrogen and electricity co-production power plants with CO{sub 2} capture

    Energy Technology Data Exchange (ETDEWEB)

    Cortes, C.G.; Tzimas, E.; Peteves, S.D.

    2009-07-01

    Integrated Gasification Combined Cycle (IGCC) plants allow the combination of the production of hydrogen and electricity because coal gasification process produces a syngas that can be used for the production of both commodities. A hydrogen and electricity power plant has been denominated as HYPOGEN. This report starts by reviewing the basics of the coal gasification process and continues by trying to map all the technological options currently available in the market as well as possible future trends that can be included in a HYPOGEN system. Besides, it offers an overview of the operating conditions and outputs of each process in order to provide the modeller with a useful information tool enabling an easier analysis of compatibilities and implementation of the model. 119 refs., 53 figs., 38 tabs.

  11. Power plant performance - resurrection of the AGR

    Energy Technology Data Exchange (ETDEWEB)

    Kovan, Dick

    1994-04-01

    When the rest of the electricity supply industry was privatized in 1990, Nuclear Electric became responsible for the running of nuclear plants in England and Wales. These included five AGR stations, the output and revenue from which have increased dramatically. The absence of a fully representative prototype reactor led to deficiencies in the design and problems in the construction and commissioning of the AGR stations, particularly the first, Dungeness B. Subsequent plant and design improvements have led to the achievement of good performance, however, and Nuclear Electric's better understanding of AGR safety has been translated into higher output because it has been possible to run nearer to the limits on power ratings, temperatures and pressures. Increased efficiency in refuelling and greater productivity of boilers, gas circulators and turbines, together with improved servicing and maintenance procedures have all contributed to a reduction in reactor downtime. These and other actions which have been employed by Nuclear Electric to turn round the fortunes of the AGR stations are discussed. (UK).

  12. Modelling and simulation of thermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Eborn, J.

    1998-02-01

    Mathematical modelling and simulation are important tools when dealing with engineering systems that today are becoming increasingly more complex. Integrated production and recycling of materials are trends that give rise to heterogenous systems, which are difficult to handle within one area of expertise. Model libraries are an excellent way to package engineering knowledge of systems and units to be reused by those who are not experts in modelling. Many commercial packages provide good model libraries, but they are usually domain-specific and closed. Heterogenous, multi-domain systems requires open model libraries written in general purpose modelling languages. This thesis describes a model database for thermal power plants written in the object-oriented modelling language OMOLA. The models are based on first principles. Subunits describe volumes with pressure and enthalpy dynamics and flows of heat or different media. The subunits are used to build basic units such as pumps, valves and heat exchangers which can be used to build system models. Several applications are described; a heat recovery steam generator, equipment for juice blending, steam generation in a sulphuric acid plant and a condensing steam plate heat exchanger. Model libraries for industrial use must be validated against measured data. The thesis describes how parameter estimation methods can be used for model validation. Results from a case-study on parameter optimization of a non-linear drum boiler model show how the technique can be used 32 refs, 21 figs

  13. The assessment of health impacts and external costs of natural gas-fired power plant of Qom.

    Science.gov (United States)

    Fouladi Fard, Reza; Naddafi, Kazem; Yunesian, Masud; Nabizadeh Nodehi, Ramin; Dehghani, Mohammad Hadi; Hassanvand, Mohammad Sadegh

    2016-10-01

    The external health damage costs of the combined cycle natural gas-fired power plant of Qom were investigated via the simplified impact pathway approach. Emitted particulate matter (PM10) and gaseous pollutants (NO x , CO, and SO2) from the power plant stack were measured The health effects and related costs were estimated by QUERI model from AirPacts according to the emissions, source and stack parameters, pollutant depletion velocities, exposure-response functions, local and regional population density, and detailed meteorological data. The results showed that the main health effect was assigned to the nitrate as restricted activity days (RAD) with 25,240 days/year. For all pollutants, the maximum health damage costs were related to the long-term mortality (49 %), restricted activity days (27 %), and chronic bronchitis (21 %). The annual health damage costs were approximately 4.76 million US$, with the cost being 0.096 US per kWh of generating electricity. Although the health damage costs of gas-fired power plant were lower than those of other heavy fuels, it seems essential to consider the health and environmental damages and focus on the emission control strategies, particularly in site selection for the new power plants and expanding the current ones.

  14. Control system design for maintaining CO{sub 2} capture in IGCC power plants while loading-following

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, D.; Turton, R.; Zitney, S.

    2012-01-01

    Load-following requirements for future integrated gasification combined cycle (IGCC) power plants with precombustion CO{sub 2} capture are expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. In this work, loadfollowing studies are performed using a comprehensive dynamic model of an IGCC plant with pre-combustion CO{sub 2} capture developed in Aspen Engineering Suite (AES). Considering multiple single-loop controllers for power demand load following, the preferred IGCC control strategy from the perspective of a power producer is gas turbine (GT) lead with gasifier follow. In this strategy, the GT controls the load by manipulating its firing rate while the slurry feed flow to the gasifier is manipulated to control the syngas pressure at the GT inlet. The syngas pressure control is an integrating process with significant time delay mainly because of the large piping and equipment volumes between the gasifier and the GT inlet. A modified proportional–integral–derivative (PID) control is considered for IGCC syngas pressure control. The desired CO{sub 2} capture rate must be maintained while the IGCC plant follows the load. For maintaining the desired CO{sub 2} capture rate, the control performance of PID control is compared with linear model predictive control (LMPC). The results show that the LMPC outperforms PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

  15. NOVEL GAS CLEANING/CONDITIONING FOR INTEGRATED GASIFICATION COMBINED CYCLE

    Energy Technology Data Exchange (ETDEWEB)

    Dennis A. Horazak; Richard A. Newby; Eugene E. Smeltzer; Rachid B. Slimane; P. Vann Bush; James L. Aderhold Jr; Bruce G. Bryan

    2005-12-01

    Development efforts have been underway for decades to replace dry-gas cleaning technology with humid-gas cleaning technology that would maintain the water vapor content in the raw gas by conducting cleaning at sufficiently high temperature to avoid water vapor condensation and would thus significantly simplify the plant and improve its thermal efficiency. Siemens Power Generation, Inc. conducted a program with the Gas Technology Institute (GTI) to develop a Novel Gas Cleaning process that uses a new type of gas-sorbent contactor, the ''filter-reactor''. The Filter-Reactor Novel Gas Cleaning process described and evaluated here is in its early stages of development and this evaluation is classified as conceptual. The commercial evaluations have been coupled with integrated Process Development Unit testing performed at a GTI coal gasifier test facility to demonstrate, at sub-scale the process performance capabilities. The commercial evaluations and Process Development Unit test results are presented in Volumes 1 and 2 of this report, respectively. Two gas cleaning applications with significantly differing gas cleaning requirements were considered in the evaluation: IGCC power generation, and Methanol Synthesis with electric power co-production. For the IGCC power generation application, two sets of gas cleaning requirements were applied, one representing the most stringent ''current'' gas cleaning requirements, and a second set representing possible, very stringent ''future'' gas cleaning requirements. Current gas cleaning requirements were used for Methanol Synthesis in the evaluation because these cleaning requirements represent the most stringent of cleaning requirements and the most challenging for the Filter-Reactor Novel Gas Cleaning process. The scope of the evaluation for each application was: (1) Select the configuration for the Filter-Reactor Novel Gas Cleaning Process, the arrangement of the

  16. Entropy production and optimization of geothermal power plants

    Science.gov (United States)

    Michaelides, Efstathios E.

    2012-09-01

    Geothermal power plants are currently producing reliable and low-cost, base load electricity. Three basic types of geothermal power plants are currently in operation: single-flashing, dual-flashing, and binary power plants. Typically, the single-flashing and dual-flashing geothermal power plants utilize geothermal water (brine) at temperatures in the range of 550-430 K. Binary units utilize geothermal resources at lower temperatures, typically 450-380 K. The entropy production in the various components of the three types of geothermal power plants determines the efficiency of the plants. It is axiomatic that a lower entropy production would improve significantly the energy utilization factor of the corresponding power plant. For this reason, the entropy production in the major components of the three types of geothermal power plants has been calculated. It was observed that binary power plants generate the lowest amount of entropy and, thus, convert the highest rate of geothermal energy into mechanical energy. The single-flashing units generate the highest amount of entropy, primarily because they re-inject fluid at relatively high temperature. The calculations for entropy production provide information on the equipment where the highest irreversibilities occur, and may be used to optimize the design of geothermal processes in future geothermal power plants and thermal cycles used for the harnessing of geothermal energy.

  17. VAr reserve concept applied to a wind power plant

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Philip C.; Rodriguez, Pedro

    2011-01-01

    a VAr management system are proposed and analyzed. Such a reactive power reserve may be provided by the wind power plant since the amount of reactive power installed for most active power working points exceeds the demand required by the grid operator. Basically, this overrated reactive power capacity......Larger percentages of wind power penetration translate into more demanding requirements from the grid codes; for example voltage support at the point of connection has been introduced recently by several grid codes from around the world, making it important to analyze this control when applied...... to wind power plants. This paper proposes two different VAr reserve control strategies for a wind power plant. The amount of dynamic VAr available most of the operation time, makes the wind power plant (WPP) a good candidate to include a VAr reserve management system. Two different ways of implementing...

  18. Power system stabilising features from wind power plants augmented with energy storage

    DEFF Research Database (Denmark)

    Tarnowski, Germán C.; Kjær, Philip C; Lærke, Rasmus

    2014-01-01

    This paper describes a wind power plant augmented with energy storage, configured to provide ancillary services (primary reserve, inertial response, power oscillation damping) for enhancement of power system stability. Energy storage can complement wind power plants thus reducing the need for any...

  19. Report on Geothermal Power Plant Cost and Comparative Cost of Geothermal and Coal Fired Steam Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-07-01

    This report is to be used by Utah Power and Light Company (UP and L) in making studies of geothermal power plants. The dollars per kilowatt comparison between a geothermal plant and a UP and L coal-fired plant is to be developed. Geothermal gathering system costs and return to owner are to be developed for information.

  20. Power electronics solution to dust emissions from thermal power plants

    Directory of Open Access Journals (Sweden)

    Vukosavić Slobodan

    2010-01-01

    Full Text Available Thermal power stations emit significant amounts of fly ash and ultra fine particles into the atmosphere. Electrostatic precipitators (ESP or electro filters remove flying ashes and fine particles from the flue gas before passing the gas into the chimney. Maximum allowable value of dust is 50 mg/m3 and it requires that the efficiency of the ESPs better than 99 %, which calls for an increase of active surface of the electrodes, hence increasing the filter volume and the weight of steel used for the filter. In previous decades, electrostatic precipitators in thermal power plants were fed by thyristor controlled, single phase fed devices having a high degree of reliability, but with a relatively low collection efficiency, hence requiring large effective surface of the collection plates and a large weight of steel construction in order to achieve the prescribed emission limits. Collection efficiency and energy efficiency of the electrostatic precipitator can be increased by applying high frequency high voltage power supply (HF HV. Electrical engineering faculty of the University of Belgrade (ETF has developed technology and HF HV equipment for the ESP power supply. This solution was subjected to extensive experimental investigation at TE Morava from 2008 to 2010. High frequency power supply is proven to reduce emission two times in controlled conditions while increasing energy efficiency of the precipitator, compared to the conventional thyristor controlled 50Hz supply. Two high frequency high voltage unit AR70/1000 with parameters 70 kV and 1000 mA are installed at TE Morava and thoroughly testes. It was found that the HF HV power supply of the ESP at TE Morava increases collection efficiency so that emission of fine particles and flying ashes are halved, brought down to only 50 % of the emissions encountered with conventional 50 Hz thyristor driven power supplies. On the basis of this study, conclusion is drawn that the equipment comprising HF HV

  1. Standardization of the water heat carrier quality at Russian thermal power plants

    Science.gov (United States)

    Larin, B. M.; Larin, A. B.; Suslov, S. Yu.; Kirilina, A. V.

    2017-04-01

    The necessity of developing a new industry-specific standard of the heat carrier quality for the operating, newly commissioned, and prospective power-generating units of the thermal power plants is substantiated. The need of extending the scope of the automatic chemical monitoring and the possibility of indirect measurements of some basic standardized and diagnostic indices of the water chemistry using the specific conductance are shown. Investigations proved the possibility of automatic chemical monitoring of the phosphating of the drum boilers and quantitative control of potentially acidic impurities in the feed water in oncethrough boilers. The normative STO NP INVEL document developed at OAO VTI in 2009 is proposed as the basis for alterations and amendments. A new index, the total organic carbon, is introduced into this document. The standardized value of this index in the drum boiler feed water and steam is 100 μg/dm3. According to the above normative document, the scope of the chemical monitoring should be extended by measurements of the specific conductance of the direct and H-cation samples of both the feed and the boiler water. The content of chlorides should also be standardized. For the first time, normative restrictions are suggested on amine-containing water chemistry of the power-generating units with the combined cycle gas turbines. Flowcharts are proposed for pretreatment of the make-up water on the basis of low-mineralized natural waters with high organic substance contents, which reduces the oxidizability by 70-80%.

  2. Development of an Equivalent Wind Plant Power-Curve: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Y. H.; Ela, E.; Orwig, K.

    2010-06-01

    Development of an equivalent wind plant power-curve becomes highly desirable and useful in predicting plant output for a given wind forecast. Such a development is described and summarized in this paper.

  3. Energy impacts of controlling carbon dioxide emissions from an integrated gasification/combined-cycle system

    Energy Technology Data Exchange (ETDEWEB)

    Livengood, C.D.; Doctor, R.D.; Molburg, J.C.; Thimmapuram, P.

    1994-08-01

    This paper presents results from a study of the impacts associated with CO{sub 2} recovery in integrated gasification/combined-cycle (IGCC) systems which is being conducted for the Morgantown Energy Technology Center by Argonne National Laboratory. The objective of the study is to compare, on a consistent systems-oriented basis, the energy and economic impacts of adding CO{sub 2} capture and sequestration to an IGCC system. The research reported here has emphasized commercial technologies for capturing CO{sub 2}, but ongoing work is also addressing advanced technologies under development and alternate power-system configurations that may enhance system efficiency.

  4. Possibilities of utilizing power plant fly ashes

    Directory of Open Access Journals (Sweden)

    Mezencevová Andrea

    2003-09-01

    Full Text Available The burning of fossil fuels in industrial power stations plays a significant role in the production of thermal and electrical energy. Modern thermal power plants are producing large amounts of solid waste, mainly fly ashes. The disposal of power plant waste is a large environmental problem at the present time. In this paper, possibilities of utilization of power plant fly ashes in industry, especially in civil engineering, are presented. The fly ash is a heterogeneous material with various physical, chemical and mineralogical properties, depending on the mineralogical composition of burned coal and on the used combustion technology. The utilization of fly ashes is determined of their properties. The fineness, specific surface area, particle shape, density, hardness, freeze-thaw resistance, etc. are decisive. The building trade is a branch of industry, which employs fly ash in large quantities for several decades.The best utilization of fluid fly ashes is mainly in the production of cement and concrete, due to the excellent pozzolanic and cementitious properties of this waste. In the concrete processing, the fly ash is utilized as a replacement of the fine aggregate (fine filler or a partial replacement for cement (active admixture. In addition to economic and ecological benefits, the use of fly ash in concrete improves its workability and durability, increases compressive and flexural strength, reduces segregation, bleeding, shrinkage, heat evolution and permeability and enhances sulfate resistance of concrete.The aim of current research is to search for new technologies for the fly ash utilization. The very interesting are biotechnological methods to recovery useful components of fly ashes and unconventional methods of modification of fly ash properties such as hydrothermal zeolitization and mechanochemical modification of its properties. Mechanochemistry deals with physico - chemical transformations and chemical reactions of solids induced by

  5. Geothermal depth power plant; Geothermie Tiefenkraftwerk trademark (GTKW)

    Energy Technology Data Exchange (ETDEWEB)

    Haemmerle, Hubert [Ehoch 10 Projektentwicklungs GmbH, Wien (Austria); Pilgerstorfer, Thomas; Schubert, Wulf [Technische Univ. Graz (Austria). Inst. fuer Felsmechanik und Tunnelbau; Radoncic, Nedim

    2012-11-01

    The authors of the contribution under consideration report on a new concept for the utilization of geothermal energy. This concept provides itself due to the size of the usable reservoir, its performance in the area of conventional caloric power plants and its pronounced availability as a base load substitution for nuclear power plants as well as conventional gas and coal-fired power plants. A basic feasibility study was concluded. In addition to basic research, a variety of development work is required.

  6. Solid Waste from the Operation and Decommissioning of Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Marilyn Ann [Georgia Inst. of Technology, Atlanta, GA (United States); D' Arcy, Daniel [Georgia Inst. of Technology, Atlanta, GA (United States); Lapsa, Melissa Voss [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Isha [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Li, Yufei [Georgia Inst. of Technology, Atlanta, GA (United States)

    2017-01-05

    This baseline report examines the solid waste generated by the U.S. electric power industry, including both waste streams resulting from electricity generation and wastes resulting from the decommissioning of power plants. Coal and nuclear plants produce large volumes of waste during electricity generation, and this report describes the policies and procedures for handling these materials. Natural gas and oil-fired power plants face similar waste challenges. Renewables considered in this baseline report include hydropower, wind and solar.

  7. Steam-Electric Power-Plant-Cooling Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sonnichsen, J.C.; Carlson, H.A.; Charles, P.D.; Jacobson, L.D.; Tadlock, L.A.

    1982-02-01

    The Steam-Electric Power Plant Cooling Handbook provides summary data on steam-electric power plant capacity, generation and number of plants for each cooling means, by Electric Regions, Water Resource Regions and National Electric Reliability Council Areas. Water consumption by once-through cooling, cooling ponds and wet evaporative towers is discussed and a methodology for computation of water consumption is provided for a typical steam-electric plant which uses a wet evaporative tower or cooling pond for cooling.

  8. Hot windbox repowering of coal-fired thermal power plants

    OpenAIRE

    YILMAZOĞLU, Mustafa Zeki; DURMAZ, Ali

    2014-01-01

    The repowering of thermal power plants could be the fastest way to respond to the energy demand while decreasing the CO2 emissions per kilowatt hour of energy generated. Hot windbox repowering of a thermal power plant was investigated in this study using Thermoflex simulations. The Soma A thermal power plant began operation in 1957 and was in service until 2010. In the current situation, the installed capacity of the power plant is 44 MWel, with 2 units. The boiler was designed to oper...

  9. Next generation geothermal power plants. Draft final report

    Energy Technology Data Exchange (ETDEWEB)

    Brugman, John; Hattar, John; Nichols, Kenneth; Esaki, Yuri

    1994-12-01

    The goal of this project is to develop concepts for the next generation geothermal power plant(s) (NGGPP). This plant, compared to existing plants, will generate power for a lower levelized cost and will be more competitive with fossil fuel fired power plants. The NGGPP will utilize geothermal resources efficiently and will be equipped with contingencies to mitigate the risk of reservoir performance. The NGGPP design will attempt to minimize emission of pollutants and consumption of surface water and/or geothermal fluids for cooling service.

  10. Optimized post-combustion capture technology for power plants

    Energy Technology Data Exchange (ETDEWEB)

    Peter Moser; Sandra Schmidt; Georg Sieder; Hugo Garcia; Ilaria Ciattaglia; Dieter Mihailowitsch; Torsten Stoffregen [RWE Power AG, New Technologies, Essen (Germany)

    2009-07-01

    The construction and operation of the post-combustion capture pilot plant at RWE Power's lignite-fired power plant at Niederaussem is the first corner stone in a joint development programme of RWE Power, BASF and Linde that started in 2007. The pilot plant will be commissioned in mid-2009. The skid-mounted pilot plant - engineering, procurement and construction by procurement and construction by Linde - comprises all significant components of a large post-combustion capture plant but on a smaller scale. In the 18-month pilot plant testing programme optimized new solvents for the capture process will be evaluated. These solvents were selected by BASF in a multi-step procedure, starting with a pre-selection, followed by lab-screening, and finalized by mini plant runs. The pilot plant will validate the performance of some capture process optimization measures that are implemented to increase the overall efficiency and reduce the costs of a commercial capture plant. The results of the pilot plant testing will be directly used to optimize the capture process configuration for a base case power plant, a 1,100 MW lignite-fired power plant with lignite pre-drying technology. The development of the commercial capture plant needs an accurate analysis of all process steps to achieve a cost efficient plant design. Apart from energy efficiency, cost-effective equipment and the optimization of plant interfaces and plant configuration are also key factors to reach the ambitious goals of this project. Based on the results of the pilot plant tests and the full-scale design study, a demonstration plant concept will be developed to prove all innovative optimization measures and to avoid the risks involved in direct up-scaling from the pilot plant to the commercial plant scale without an intermediate step. 8 figs.

  11. Aeroderivative Pratt & Whitney FT8-3 gas turbine – an interesting solution for power generation

    Directory of Open Access Journals (Sweden)

    Sorinel-Gicu TALIF

    2011-03-01

    Full Text Available The intermediate load electric power stations become more and more interesting for theelectric power market in Romania. In this context, the Combined Cycle Power Plants came as a veryattractive solution. This paper presents the results of a study regarding the use of the aeroderivativePratt & Whitney FT8-3 gas turbine, available in Romania, for the electric power generation in aCombined Cycle Power Plant. It is also analyzed the Combined Heat in Power generation with FT8-3gas turbine when saturated steam or hot water are required.

  12. Optimization Study for Integrated Solar Combined Cycle System%太阳能燃气联合循环系统集成优化研究

    Institute of Scientific and Technical Information of China (English)

    李元媛; 袁晶; 杨勇平

    2014-01-01

    Integrated Solar Combined Cycle System,which integrates parabolic trough solar technology with combined cycle power plant,is an efficient way to make full use of solar energy,improve system thermal efficiency,save the fossil fuels and reduce CO2 emission.Based on an Integrated Solar Combined Cycle consisting of a Direct Steam Generation parabolic trough field,this paper analyzes how and where solar energy is input into ISCC system would have impact on the solar and system overall efficiencies.A preliminary economic assessment is also carried out,showing that the optimal system performance can be achieved when the solar heat input is 75% of the total latent heat required for water evaporation.%太阳能燃气联合循环系统(ISCC)将槽式太阳能与燃气轮机联合循环相结合,充分利用太阳能作为中低温加热热源,是提高太阳能发电效率,降低太阳能发电成本,并减少系统CO2排放的有效途径.本文针对太阳能直接蒸汽发生系统(DSG)与燃气轮机联合循环(CCGT)集成的系统,研究了太阳能蒸发给水份额对系统性能的影响,寻求最佳的系统集成模式,并对其经济性能做了初步的探讨.结果表明,太阳能蒸发给水份额为75%时,系统性能最优.

  13. Inspection of Nuclear Power Plant Containment Structures

    Energy Technology Data Exchange (ETDEWEB)

    Graves, H.L.; Naus, D.J.; Norris, W.E.

    1998-12-01

    Safety-related nuclear power plant (NPP) structures are designed to withstand loadings from a number of low-probability external and interval events, such as earthquakes, tornadoes, and loss-of-coolant accidents. Loadings incurred during normal plant operation therefore generally are not significant enough to cause appreciable degradation. However, these structures are susceptible to aging by various processes depending on the operating environment and service conditions. The effects of these processes may accumulate within these structures over time to cause failure under design conditions, or lead to costly repair. In the late 1980s and early 1990s several occurrences of degradation of NPP structures were discovered at various facilities (e.g., corrosion of pressure boundary components, freeze- thaw damage of concrete, and larger than anticipated loss of prestressing force). Despite these degradation occurrences and a trend for an increasing rate of occurrence, in-service inspection of the safety-related structures continued to be performed in a somewhat cursory manner. Starting in 1991, the U.S. Nuclear Regulatory Commission (USNRC) published the first of several new requirements to help ensure that adequate in-service inspection of these structures is performed. Current regulatory in-service inspection requirements are reviewed and a summary of degradation experience presented. Nondestructive examination techniques commonly used to inspect the NPP steel and concrete structures to identify and quantify the amount of damage present are reviewed. Finally, areas where nondestructive evaluation techniques require development (i.e., inaccessible portions of the containment pressure boundary, and thick heavily reinforced concrete sections are discussed.

  14. Life Cycle Assessment of a HYSOL Concentrated Solar Power Plant: Analyzing the Effect of Geographic Location

    Directory of Open Access Journals (Sweden)

    Blanca Corona

    2016-05-01

    Full Text Available Concentrating Solar Power (CSP technology is developing in order to achieve higher energy efficiency, reduced economic costs, and improved firmness and dispatchability in the generation of power on demand. To this purpose, a research project titled HYSOL has developed a new power plant, consisting of a combined cycle configuration with a 100 MWe steam turbine and an 80 MWe gas-fed turbine with biomethane. Technological developments must be supported by the identification, quantification, and evaluation of the environmental impacts produced. The aim of this paper is to evaluate the environmental performance of a CSP plant based on HYSOL technology using a Life Cycle Assessment (LCA methodology while considering different locations. The scenarios investigated include different geographic locations (Spain, Chile, Kingdom of Saudi Arabia, Mexico, and South Africa, an alternative modelling procedure for biomethane, and the use of natural gas as an alternative fuel. Results indicate that the geographic location has a significant influence on the environmental profile of the HYSOL CSP plant. The results obtained for the HYSOL configuration located in different countries presented significant differences (between 35% and 43%, depending on the category, especially in climate change and water stress categories. The differences are mainly attributable to the local availability of solar and water resources and composition of the national electricity mix. In addition, HYSOL technology performs significantly better when hybridizing with biomethane instead of natural gas. This evidence is particularly relevant in the climate change category, where biomethane hybridization emits 27.9–45.9 kg CO2 eq per MWh (depending on the biomethane modelling scenario and natural gas scenario emits 264 kg CO2 eq/MWh.

  15. Preliminary evaluation of the profitability indexes of the Laguna Verde nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-10-15

    The Laguna Verde nuclear power plant of the Federal Commission of Electricity has an installed capacity of 1,350 MW and unit 1 started commercial operation in 1990 and unit 2 in 1995. This paper is a synthesis of the results of a preliminary evaluation of the expected profitability indexes of the power plant during an economic lifetime of 40 years. The following data was used as input to the evaluation model prescribed by the Finance and Public Credit Secretary for public investment projects. Unit investment cost: 3,500 US D/k W; Fixed operation and maintenance cost: 54.{sup 45} US D/year-k W; Variable operation and maintenance cost: 0.{sup 38} US D/M Wh; Nuclear fuel cycle cost: 10.{sup 28} US D/M Wh; Lifetime capacity factor: 85%; Discount rate: 12.0% per year; Sale price of electricity to the interconnected electric system: 80.{sup 75} US D/M Wh. The output of the evaluation model is the following: Cost of electricity generated: 60.{sup 2}1 US D/M Wh; fixed cost 49.{sup 55} US D/M Wh; variable cost 10.{sup 66} US D/M Wh; Internal rate of return (Irr): 18.0%; Benefit to cost quotient (B/C): 1.341. A very systematic sensitivity analysis was done, that shows that the cost is very sensitive to the capacity factor and to the investment cost, but is very insensitive to the fixed operation and maintenance cost and to the nuclear fuel cost. Finally, a comparison was made to the evaluation of the profitability indexes of a natural gas fired combined cycle power plant. (Author)

  16. VAr reserve concept applied to a wind power plant

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Philip C.; Rodriguez, Pedro

    2011-01-01

    is a consequence of sizing wind turbine facilities for maximum active power level. The reactive power losses, due to active power transportation inside the plant (normally two transformers), and P-Q wind turbine characteristics define the P-Q reserve chart. By utilizing the intrinsic overrated reactive power...

  17. Municipal solid wastes incineration with combined cycle: a case study from Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Cerda Balcazar, Juan Galvarino; Dias, Rubens Alves; Balestieri, Jose Antonio Perrella [Universidade Estadual Paulista (UNESP), Guaratingueta, SP (Brazil)], E-mails: pos09007@feg.unesp.br, rubdias@feg.unesp.br

    2010-07-01

    Large urban centers have a huge demand for electricity, for the needs of its residents, and a growing problem of management of solid waste generated by it, that becomes an public administrative and great social problem. The correct disposal of solid waste generated by large urban centers is now one of the most complex engineering problems involving logistics, safety, environment, energy spent among other tools for sound management of municipal solid waste (MSW). This study was carried out a study of the use of incinerators and residue derived fuel and MSW with combined cycles, with the aim of producing thermal and mechanical energy (this later becomes electrical energy) and solid waste treatment in Sao Paulo. We used existing models and real plants in the European Union in this case, with the aim of making it the most viable and compatible with th