WorldWideScience

Sample records for combined imaging optical

  1. Combining calcium imaging with other optical techniques.

    Science.gov (United States)

    Canepari, Marco; Zecevic, Dejan; Vogt, Kaspar E; Ogden, David; De Waard, Michel

    2013-12-01

    Ca(2+) imaging is a commonly used approach for measuring Ca(2+) signals at high spatial resolution. The method is often combined with electrode recordings to correlate electrical and chemical signals or to investigate Ca(2+) signals following an electrical stimulation. To obtain information on electrical activity at the same spatial resolution, Ca(2+) imaging must be combined with membrane potential imaging. Similarly, stimulation of subcellular compartments requires photostimulation. Thus, combining Ca(2+) imaging with an additional optical technique facilitates the study of a number of physiological questions. The aim of this article is to introduce some basic principles regarding the combination of Ca(2+) imaging with other optical techniques. We discuss the design of the optics, the design of experimental protocols, the optical characteristics of Ca(2+) indicators used in combination with an optical probe, and the affinity of the Ca(2+) indicator in relation to the type of measurement. This information will enable the reader to devise an optimal strategy for combined optical experiments.

  2. All-optically integrated multimodality imaging system: combined photoacoustic microscopy, optical coherence tomography, and fluorescence imaging

    Science.gov (United States)

    Chen, Zhongjiang; Yang, Sihua; Xing, Da

    2016-10-01

    We have developed a multimodality imaging system by optically integrating all-optical photoacoustic microscopy (AOPAM), optical coherence tomography (OCT) and fluorescence microscopy (FLM) to provide complementary information including optical absorption, optical back-scattering and fluorescence contrast of biological tissue. By sharing the same low-coherence Michelson interferometer, AOPAM and OCT could be organically optically combined to obtain the absorption and scattering information of the biological tissues. Also, owing to using the same laser source and objective lens, intrinsically registered photoacoustic and fluorescence signals are obtained to present the radiative and nonradiative transition process of absorption. Simultaneously photoacoustic angiography, tissue structure and fluorescence molecular in vivo images of mouse ear were acquired to demonstrate the capabilities of the optically integrated trimodality imaging system, which can present more information to study tumor angiogenesis, vasculature, anatomical structure and microenvironments in vivo.

  3. An integral design strategy combining optical system and image processing to obtain high resolution images

    Science.gov (United States)

    Wang, Jiaoyang; Wang, Lin; Yang, Ying; Gong, Rui; Shao, Xiaopeng; Liang, Chao; Xu, Jun

    2016-05-01

    In this paper, an integral design that combines optical system with image processing is introduced to obtain high resolution images, and the performance is evaluated and demonstrated. Traditional imaging methods often separate the two technical procedures of optical system design and imaging processing, resulting in the failures in efficient cooperation between the optical and digital elements. Therefore, an innovative approach is presented to combine the merit function during optical design together with the constraint conditions of image processing algorithms. Specifically, an optical imaging system with low resolution is designed to collect the image signals which are indispensable for imaging processing, while the ultimate goal is to obtain high resolution images from the final system. In order to optimize the global performance, the optimization function of ZEMAX software is utilized and the number of optimization cycles is controlled. Then Wiener filter algorithm is adopted to process the image simulation and mean squared error (MSE) is taken as evaluation criterion. The results show that, although the optical figures of merit for the optical imaging systems is not the best, it can provide image signals that are more suitable for image processing. In conclusion. The integral design of optical system and image processing can search out the overall optimal solution which is missed by the traditional design methods. Especially, when designing some complex optical system, this integral design strategy has obvious advantages to simplify structure and reduce cost, as well as to gain high resolution images simultaneously, which has a promising perspective of industrial application.

  4. Integrated structural and functional optical imaging combining spectral-domain optical coherence and multiphoton microscopy

    CERN Document Server

    Vinegoni, C; Luo, W; Marks, D L; Ralston, T; Tan, W

    2005-01-01

    An integrated microscope that combines different optical techniques for simultaneous imaging is demonstrated. The microscope enables spectral-domain optical coherence microscopy based on optical backscatter, and multi-photon microscopy for the detection of two-photon fluorescence and second harmonic generation signals. The unique configuration of this integrated microscope allows for the simultaneous acquisition of both anatomical (structural) and functional imaging information with particular emphasis for applications in the fields of tissue engineering and cell biology. In addition, the contemporary analysis of the spectroscopic features can enhance contrast by differentiating among different tissue components.

  5. Combined Use of Multi-Temporal Optical and Radar Satellite Images for Grassland Monitoring

    Directory of Open Access Journals (Sweden)

    Pauline Dusseux

    2014-06-01

    Full Text Available The aim of this study was to assess the ability of optical images, SAR (Synthetic Aperture Radar images and the combination of both types of data to discriminate between grasslands and crops in agricultural areas where cloud cover is very high most of the time, which restricts the use of visible and near-infrared satellite data. We compared the performances of variables extracted from four optical and five SAR satellite images with high/very high spatial resolutions acquired during the growing season. A vegetation index, namely the NDVI (Normalized Difference Vegetation Index, and two biophysical variables, the LAI (Leaf Area Index and the fCOVER (fraction of Vegetation Cover were computed using optical time series and polarization (HH, VV, HV, VH. The polarization ratio and polarimetric decomposition (Freeman–Durden and Cloude–Pottier were calculated using SAR time series. Then, variables derived from optical, SAR and both types of remotely-sensed data were successively classified using the Support Vector Machine (SVM technique. The results show that the classification accuracy of SAR variables is higher than those using optical data (0.98 compared to 0.81. They also highlight that the combination of optical and SAR time series data is of prime interest to discriminate grasslands from crops, allowing an improved classification accuracy.

  6. Neutron, fluorescence, and optical imaging: An in situ combination of complementary techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, D.; Egelhaaf, S. U.; Hermes, H. E. [Condensed Matter Physics Laboratory, Heinrich Heine University, 40225 Düsseldorf (Germany); Börgardts, M.; Müller, T. J. J. [Institute for Organic and Macromolecular Chemistry, Heinrich Heine University, 40225 Düsseldorf (Germany); Grünzweig, C.; Lehmann, E. [Neutron Imaging and Activation Group, Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2015-09-15

    An apparatus which enables the simultaneous combination of three complementary imaging techniques, optical imaging, fluorescence imaging, and neutron radiography, is presented. While each individual technique can provide information on certain aspects of the sample and their time evolution, a combination of the three techniques in one setup provides a more complete and consistent data set. The setup can be used in transmission and reflection modes and thus with optically transparent as well as opaque samples. Its capabilities are illustrated with two examples. A polymer hydrogel represents a transparent sample and the diffusion of fluorescent particles into and through this polymer matrix is followed. In reflection mode, the absorption of solvent by a nile red-functionalized mesoporous silica powder and the corresponding change in fluorescent signal are studied.

  7. Hybrid Microscopy: Enabling Inexpensive High-Performance Imaging through Combined Physical and Optical Magnifications.

    Science.gov (United States)

    Zhang, Yu Shrike; Chang, Jae-Byum; Alvarez, Mario Moisés; Trujillo-de Santiago, Grissel; Aleman, Julio; Batzaya, Byambaa; Krishnadoss, Vaishali; Ramanujam, Aishwarya Aravamudhan; Kazemzadeh-Narbat, Mehdi; Chen, Fei; Tillberg, Paul W; Dokmeci, Mehmet Remzi; Boyden, Edward S; Khademhosseini, Ali

    2016-03-15

    To date, much effort has been expended on making high-performance microscopes through better instrumentation. Recently, it was discovered that physical magnification of specimens was possible, through a technique called expansion microscopy (ExM), raising the question of whether physical magnification, coupled to inexpensive optics, could together match the performance of high-end optical equipment, at a tiny fraction of the price. Here we show that such "hybrid microscopy" methods--combining physical and optical magnifications--can indeed achieve high performance at low cost. By physically magnifying objects, then imaging them on cheap miniature fluorescence microscopes ("mini-microscopes"), it is possible to image at a resolution comparable to that previously attainable only with benchtop microscopes that present costs orders of magnitude higher. We believe that this unprecedented hybrid technology that combines expansion microscopy, based on physical magnification, and mini-microscopy, relying on conventional optics--a process we refer to as Expansion Mini-Microscopy (ExMM)--is a highly promising alternative method for performing cost-effective, high-resolution imaging of biological samples. With further advancement of the technology, we believe that ExMM will find widespread applications for high-resolution imaging particularly in research and healthcare scenarios in undeveloped countries or remote places.

  8. Hybrid Microscopy: Enabling Inexpensive High-Performance Imaging through Combined Physical and Optical Magnifications

    Science.gov (United States)

    Zhang, Yu Shrike; Chang, Jae-Byum; Alvarez, Mario Moisés; Trujillo-de Santiago, Grissel; Aleman, Julio; Batzaya, Byambaa; Krishnadoss, Vaishali; Ramanujam, Aishwarya Aravamudhan; Kazemzadeh-Narbat, Mehdi; Chen, Fei; Tillberg, Paul W.; Dokmeci, Mehmet Remzi; Boyden, Edward S.; Khademhosseini, Ali

    2016-03-01

    To date, much effort has been expended on making high-performance microscopes through better instrumentation. Recently, it was discovered that physical magnification of specimens was possible, through a technique called expansion microscopy (ExM), raising the question of whether physical magnification, coupled to inexpensive optics, could together match the performance of high-end optical equipment, at a tiny fraction of the price. Here we show that such “hybrid microscopy” methods—combining physical and optical magnifications—can indeed achieve high performance at low cost. By physically magnifying objects, then imaging them on cheap miniature fluorescence microscopes (“mini-microscopes”), it is possible to image at a resolution comparable to that previously attainable only with benchtop microscopes that present costs orders of magnitude higher. We believe that this unprecedented hybrid technology that combines expansion microscopy, based on physical magnification, and mini-microscopy, relying on conventional optics—a process we refer to as Expansion Mini-Microscopy (ExMM)—is a highly promising alternative method for performing cost-effective, high-resolution imaging of biological samples. With further advancement of the technology, we believe that ExMM will find widespread applications for high-resolution imaging particularly in research and healthcare scenarios in undeveloped countries or remote places.

  9. Usefulness of combined fat- and fluid-suppressed SPIR-FLAIR images in optic neurits : Comparison with fat-suppressed SPIR or STIR images

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Yeon; Son, Seok Hyun; Eun, Choong Ki; Han, Sang Suk [Inje Univ., College of Medicine, Pusan (Korea, Republic of)

    2001-12-01

    To compare the usefulness of combined fat- and fluid-suppressed selective partial inversion recovery-fluid attenuated inversion recovery(SPIR-FLAIR) images in the detection of high signal intensity of the optic nerve in optic neuritis with that of fat-suppressed selective partial inversion recovery(SPIR) or short inversion time inversion recovery(STIR) images. Two radiologists independently analyzed randomly mixed MR images of 16 lesions in 14 patients (M:F=7:7; mean age, 40 years) in whom optic neuritis had been clinically diagnosed. All subjects underwent both SPIR-FLAIR and fat-suppressed SPIR or STIR imaging, in a blind fashion. In order to evaluate the optic nerve, coronal images perpendicular to its long axis were obtained. The detection rate of high signal intensity of the optic nerve, the radiologists preferred imaging sequences, and intersubject consistency of detection were evaluated. 'High signal intensity' was defined as the subjective visual evaluation of increased signal intensity compared with that of the contralateral optic nerve or that of white matter. The mean detection rate of high signal intensity of the optic nerve was 90% for combined fat- and fluid-suppressed SPIR-FLAIR images, and 59% for fat-suppressed SPIR or STIR images. In all cases in which the signal intensity observed on SPIR-FLAIR images was normal, that on fat-suppressed SPIR or STIR images was also normal. The radiologists preferred the contrast properties of SPIR-FLAIR to those of fat-suppressed SPIR or STIR images. In the diagnosis of optic neuritis using MRI, combined fat- and fluid-suppressed SPIR-FLAIR images were more useful for the detection of high signal intensity of the optic nerve than fat-suppressed SPIR or STIR images. For the evaluation of optic neuritis, combined fat- and fluid-suppressed SPIR-FLAIR imaging is superior to fat-suppressed SPIR or STIR imaging.

  10. Negative hemodynamic response without neuronal inhibition investigated by combining optical imaging and electrophysiological recording.

    Science.gov (United States)

    Ma, Zengguang; Cao, Pengjia; Sun, Pengcheng; Lu, Zhuofan; Li, Liming; Chen, Yao; Chai, Xinyu

    2017-01-10

    Understanding the mechanisms underlying negative hemodynamic responses is critical for the interpretation of functional brain imaging signals. Negative imaging signals have been found in the visual, somatosensory and motor cortices in functional magnetic resonance imaging (fMRI) and intrinsic signal optical imaging (ISOI) studies. However, the origin of negative imaging signals is still controversial. The present study investigated the visual cortical responses to peripheral grating stimuli using multi-wavelength ISOI and electrophysiological recording. We found an increased cerebral blood volume (CBV) in the stimulus-induced regions and a decreased CBV in the adjacent regions in the visual cortex. Nevertheless, there was no significant change in blood oxygenation in the negative CBV regions. Furthermore, by combining the planar and laminar electrophysiological recordings, we did not observe significantly decreased neuronal activity in the negative CBV regions. Our results suggest that the negative hemodynamic response does not necessarily originate in decreased neuronal activity. Therefore, caution should be taken when interpreting a negative hemodynamic response as neuronal inhibition.

  11. Far-red light activatable, multifunctional prodrug for fluorescence optical imaging and combinational treatment.

    Science.gov (United States)

    Bio, Moses; Rajaputra, Pallavi; Nkepang, Gregory; You, Youngjae

    2014-04-24

    We recently developed "photo-unclick chemistry", a novel chemical tool involving the cleavage of aminoacrylate by singlet oxygen, and demonstrated its application to visible light-activatable prodrugs. In this study, we prepared an advanced multifunctional prodrug, Pc-(L-CA4)2, composed of the fluorescent photosensitizer phthalocyanine (Pc), an SO-labile aminoacrylate linker (L), and a cytotoxic drug combretastatin A-4 (CA4). Pc-(L-CA4)2 had reduced dark toxicity compared with CA4. However, once illuminated, it showed improved toxicity similar to CA4 and displayed bystander effects in vitro. We monitored the time-dependent distribution of Pc-(L-CA4)2 using optical imaging with live mice. We also effectively ablated tumors by the illumination with far-red light to the mice, presumably through the combined effects of photodynamic therapy (PDT) and released chemotherapy drug, without any sign of acute systemic toxicity.

  12. Detection of the optic disc in fundus images by combining probability models.

    Science.gov (United States)

    Harangi, Balazs; Hajdu, Andras

    2015-10-01

    In this paper, we propose a combination method for the automatic detection of the optic disc (OD) in fundus images based on ensembles of individual algorithms. We have studied and adapted some of the state-of-the-art OD detectors and finally organized them into a complex framework in order to maximize the accuracy of the localization of the OD. The detection of the OD can be considered as a single-object detection problem. This object can be localized with high accuracy by several algorithms extracting single candidates for the center of the OD and the final location can be defined using a single majority voting rule. To include more information to support the final decision, we can use member algorithms providing more candidates which can be ranked based on the confidence ordered by the algorithms. In this case, a spatial weighted graph is defined where the candidates are considered as its nodes, and the final OD position is determined in terms of finding a maximum-weighted clique. Now, we examine how to apply in our ensemble-based framework all the accessible information supplied by the member algorithms by making them return confidence values for each image pixel. These confidence values inform us about the probability that a given pixel is the center point of the object. We apply axiomatic and Bayesian approaches, as in the case of aggregation of judgments of experts in decision and risk analysis, to combine these confidence values. According to our experimental study, the accuracy of the localization of OD increases further. Besides single localization, this approach can be adapted for the precise detection of the boundary of the OD. Comparative experimental results are also given for several publicly available datasets.

  13. Combining 3D optical imaging and dual energy absorptiometry to measure three compositional components

    Science.gov (United States)

    Malkov, Serghei; Shepherd, John

    2014-02-01

    We report on the design of the technique combining 3D optical imaging and dual-energy absorptiometry body scanning to estimate local body area compositions of three compartments. Dual-energy attenuation and body shape measures are used together to solve for the three compositional tissue thicknesses: water, lipid, and protein. We designed phantoms with tissue-like properties as our reference standards for calibration purposes. The calibration was created by fitting phantom values using non-linear regression of quadratic and truncated polynomials. Dual-energy measurements were performed on tissue-mimicking phantoms using a bone densitometer unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the biological compositional compartments. The components for the solid phantom were tested and their high energy/low energy attenuation ratios are in good correspondent to water, lipid, and protein for the densitometer x-ray region. The three-dimensional body shape was reconstructed from the depth maps generated by Microsoft Kinect for Windows. We used open-source Point Cloud Library and freeware software to produce dense point clouds. Accuracy and precision of compositional and thickness measures were calculated. The error contributions due to two modalities were estimated. The preliminary phantom composition and shape measurements are found to demonstrate the feasibility of the method proposed.

  14. What advances in microscopy are required for combined MRI and optical functional brain imaging? (Conference Presentation)

    Science.gov (United States)

    Kleinfeld, David

    2016-03-01

    This overview talk will focus on forward-looking scientific needs and physical limits to images of neuronal processes. The challenge in nervous systems is that the basic unit for "switching" events in the nervous system occurs on the one micrometer scale of synaptic spines, while computations involve communication between individual neurons across the full expanse of cortex, which is ten millimeters for mouse cortex. I will address hoped-for advances in optical microscopy, within the context of existing and proposed contrast mechanisms of neuronal function, that span the four orders of magnitude of length scales for neuronal processing

  15. Acousto-optic laser optical feedback imaging

    CERN Document Server

    Jacquin, Olivier; Lacot, Eric; Hugon, Olivier; De Chatellus, Hugues Guillet; François, Ramaz

    2012-01-01

    We present a photon noise and diffraction limited imaging method combining the imaging laser and ultrasonic waves. The laser optical feedback imaging (LOFI) technique is an ultrasensitive imaging method for imaging objects through or embedded within a scattering medium. However, LOFI performances are dramatically limited by parasitic optical feedback occurring in the experimental setup. In this work, we have tagged the ballistic photons by an acousto-optic effect in order to filter the parasitic feedback effect and to reach the theoretical and ultimate sensitivity of the LOFI technique. We present the principle and the experimental setup of the acousto-optic laser optical feedback imaging (AO-LOFI) technique, and we demonstrate the suppression of the parasitic feedback.

  16. Imaging of the magnetic field structure in megagauss plasmas by combining pulsed polarimetry with an optical Kerr effect shutter technique.

    Science.gov (United States)

    Smith, R J

    2010-10-01

    Pulsed polarimetry in combination with a high speed photographic technique based on the optical Kerr effect is described. The backscatter in a pulsed polarimeter is directed through a scattering cell and photographed using an ∼1 ps shutter, essentially freezing the intensity pattern. The image provides both the local electron density and magnetic field distributions along and transverse to the laser sightline. Submillimeter spatial resolution is possible for probing wavelengths in the visible due to the high densities and strong optical activity. Pulsed polarimetry is thereby extended to centimeter-sized plasmas with n(e)>10(19)-10(20) cm(-3) and B>20-100 T (MG) produced by multiterawatt, multimega-ampere electrical drivers, wire Z pinches, and liner imploded magnetized plasmas.

  17. Machine Learning on Images: Combining Passive Microwave and Optical Data to Estimate Snow Water Equivalent

    Science.gov (United States)

    Dozier, J.; Tolle, K.; Bair, N.

    2014-12-01

    We have a problem that may be a specific example of a generic one. The task is to estimate spatiotemporally distributed estimates of snow water equivalent (SWE) in snow-dominated mountain environments, including those that lack on-the-ground measurements. Several independent methods exist, but all are problematic. The remotely sensed date of disappearance of snow from each pixel can be combined with a calculation of melt to reconstruct the accumulated SWE for each day back to the last significant snowfall. Comparison with streamflow measurements in mountain ranges where such data are available shows this method to be accurate, but the big disadvantage is that SWE can only be calculated retroactively after snow disappears, and even then only for areas with little accumulation during the melt season. Passive microwave sensors offer real-time global SWE estimates but suffer from several issues, notably signal loss in wet snow or in forests, saturation in deep snow, subpixel variability in the mountains owing to the large (~25 km) pixel size, and SWE overestimation in the presence of large grains such as depth and surface hoar. Throughout the winter and spring, snow-covered area can be measured at sub-km spatial resolution with optical sensors, with accuracy and timeliness improved by interpolating and smoothing across multiple days. So the question is, how can we establish the relationship between Reconstruction—available only after the snow goes away—and passive microwave and optical data to accurately estimate SWE during the snow season, when the information can help forecast spring runoff? Linear regression provides one answer, but can modern machine learning techniques (used to persuade people to click on web advertisements) adapt to improve forecasts of floods and droughts in areas where more than one billion people depend on snowmelt for their water resources?

  18. Optical image encryption topology.

    Science.gov (United States)

    Yong-Liang, Xiao; Xin, Zhou; Qiong-Hua, Wang; Sheng, Yuan; Yao-Yao, Chen

    2009-10-15

    Optical image encryption topology is proposed based on the principle of random-phase encoding. Various encryption topological units, involving peer-to-peer, ring, star, and tree topologies, can be realized by an optical 6f system. These topological units can be interconnected to constitute an optical image encryption network. The encryption and decryption can be performed in both digital and optical methods.

  19. Optical imaging and spectroscopy

    CERN Document Server

    Brady, David J

    2009-01-01

    An essential reference for optical sensor system design This is the first text to present an integrated view of the optical and mathematical analysis tools necessary to understand computational optical system design. It presents the foundations of computational optical sensor design with a focus entirely on digital imaging and spectroscopy. It systematically covers: Coded aperture and tomographic imaging Sampling and transformations in optical systems, including wavelets and generalized sampling techniques essential to digital system analysis Geometric, wave, and statis

  20. Fast optical measurements and imaging of flow mixing: Fast optical measurements and imaging of temperature in combined fossil fuel and biomass/waste systems

    Energy Technology Data Exchange (ETDEWEB)

    Clausen, Soennik; Fateev, A.; Lindorff Nielsen, K.; Evseev, V.

    2012-02-15

    Project is focused on fast time-resolved infrared measurements of gas temperature and fast IR-imagining of flames in various combustion environments. The infrared spectrometer system was developed in the project for fast infrared spectral measurements on industrial scale using IR-fibre- optics. Fast time-and spectral-resolved measurements in 1.5-5.1 mu spectral range give information about flame characteristics like gas and particle temperatures, eddies and turbulent gas mixing. Time-resolved gas composition in that spectral range (H{sub 2}O, CH{sub 4}, CO{sub 2}, CO) which is one of the key parameters in combustion enhancement can be also obtained. The infrared camera was also used together with special endoscope optics for fast thermal imaging of a coal-straw flame in an industrial boiler. Obtained time-resolved infrared images provided useful information for the diagnostics of the flame and fuel distribustion. The applicability of the system for gas leak detection is also demonstrated. The infrared spectrometer system with minor developments was applied for fast time-resolved exhaust gas temperature measurements performed simultaneously at the three optical ports of the exhaust duct of a marine Diesel engine and visualisation of gas flow behaviour in cylinder. (Author)

  1. Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging

    Science.gov (United States)

    Werkmeister, René M.; Vietauer, Martin; Knopf, Corinna; Fürnsinn, Clemens; Leitgeb, Rainer A.; Reitsamer, Herbert; Gröschl, Martin; Garhöfer, Gerhard; Vilser, Walthard; Schmetterer, Leopold

    2014-10-01

    A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in the rat using a new optical system that combines the measurement of blood flow velocities via Doppler Fourier-domain optical coherence tomography and the measurement of vessel diameters using a fundus camera-based technique. Relying on fundus images for extraction of retinal vessel diameters instead of OCT images improves the reliability of the technique. The system was operated with an 841-nm superluminescent diode and a charge-coupled device camera that could be operated at a line rate of 20 kHz. We show that the system is capable of quantifying the response of 100% oxygen breathing on the retinal blood flow. In six rats, we observed a decrease in retinal vessel diameters of 13.2% and a decrease in retinal blood velocity of 42.6%, leading to a decrease in retinal blood flow of 56.7%. Furthermore, in four rats, the response of retinal blood flow during stimulation with diffuse flicker light was assessed. Retinal vessel diameter and blood velocity increased by 3.4% and 28.1%, respectively, leading to a relative increase in blood flow of 36.2%;. The presented technique shows much promise to quantify early changes in retinal blood flow during provocation with various stimuli in rodent models of ocular diseases in rats.

  2. The combination of pulsed acousto-optic imaging and B-mode diagnostic ultrasound for three-dimensional imaging in ex vivo biological tissue

    Science.gov (United States)

    Sui, Lei; Murray, Todd W.; Roy, Ronald A.

    2006-02-01

    A multimode imaging system, producing conventional ultrasound (US) and acousto-optic (AO) images, has been developed and used to detect optical absorbers buried in excised biological tissue. A commercially-available diagnostic ultrasound imaging transducer is used to both generate B-mode ultrasound images and as a pump for AO imaging. Due to the fact that the steered and focused beam used for US imaging and the US source for pumping the AO image are generated from the same ultrasound probe, the acoustical and optical images are intrinsically co-registered. AO imaging is performed using short ultrasound pulse trains at a frequency of 5 MHz. The phase-modulated light emitted from the interaction region is detected using a photorefractive-crystal based interferometry system. Experimental results have previously been presented for the two-dimensional imaging in tissue-mimicking phantoms. In this paper, we report further experimental developments demonstrating three-dimensional fusion of B-mode ultrasound imaging and pulsed acousto-optic imaging in excised biological tissue (~2 cm thick). By mechanically scanning the ultrasound transducer array in a direction perpendicular to its imaging plane, both the acoustical and optical properties of an embedded target are obtained in three dimensions. The results suggest that AO imaging could be used to supplement conventional B-mode ultrasound imaging with optical contrast, and the multimode imaging system may find application in the detection and diagnosis of cancer.

  3. Towards quantitative tissue absorption imaging by combining photoacoustics and acousto-optics

    CERN Document Server

    Daoudi, Khalid

    2012-01-01

    We propose a strategy for quantitative photoacoustic mapping of chromophore concentrations that can be performed purely experimentally. We exploit the possibility of acousto-optic modulation using focused ultrasound, and the principle that photons follow trajectories through a turbid medium in two directions with equal probability. A theory is presented that expresses the local absorption coefficient inside a medium in terms of noninvasively measured quantities and experimental parameters. Proof of the validity of the theory is given with Monte Carlo simulations.

  4. Combined Use of SAR and Optical Satellite Images for Landscape Diversity Assessment

    Science.gov (United States)

    Kuchma, Tetyana

    2016-08-01

    Land cover change analysis is essential for effective land use management and biodiversity conservation. The advantages of Sentinel-1 and Landsat-8 image fusion for land cover classification and landscape diversity maps development were studied. The methodology of landscape metrics interpretation for sustainable land use planning is developed and tested on agricultural landscapes in Ukraine.

  5. Image-guided optical spectroscopy in diagnosis of osteoarthritis by combining spectral and spatial a-priori information

    Science.gov (United States)

    Yuan, Zhen; Zhang, Qizhi; Jiang, Huizhu; Sobel, Eric S.; Jiang, Huabei

    2009-02-01

    A multi-modality imaging approach and instrument that integrate optical imaging system and near-infrared spectroscopy into an x-ray tomosynthesis setup have been employed to perform a clinical study of image-guided spectroscopy on osteoarthritis (OA) in the finger joints. The multiwavelength spectroscopy of the joints using x-ray-guided spatial constraints provides 3D images of oxygen saturation and water content with high resolution and improved quantitative capability. Based on the recovered quantitative results from 18 healthy volunteers and 22 patients, we observed that oxygen saturation and water content were significant discriminators for differentiation of healthy joints from diseased ones. The recovered images appear to show that the OA joints have high water values and decreased oxygen saturation.

  6. Simultaneous observation of collagen and elastin based on the combined nonlinear optical imaging technique coupled with two-channel synchronized detection method

    Science.gov (United States)

    Chen, Jianxin; Zhuo, Shuangmu; Luo, Tianshu; Liu, Dingzhong; Zhao, Jingjun

    2008-08-01

    Collagen and elastin are the most important proteins of the connective tissues in higher vertebrates. In this paper, we present a combined nonlinear optical imaging technique of second-harmonic generation and two-photon excited fluorescence to simultaneously observe the collagen and elastic fiber of dermis in a freshly excised human skin and rabbit aorta using a two-channel synchronized detection method. The obtained two-channel overlay image in the backward direction can clearly distinguish the morphological structure and distribution of collagen and elastic fibers. Tissue spectrum further confirms the obtained structural information. These results suggest that the combined nonlinear optical imaging technique coupled with two-channel synchronized detection method can be an effective tool for detecting collage and elastic fibers without any invasive tissue procedure of slicing, embedding, fixation and staining when two structural proteins are simultaneously present in the biological tissue.

  7. Optical imaging and metrology

    CERN Document Server

    Osten, Wolfgang

    2012-01-01

    A comprehensive review of the state of the art and advances in the field, while also outlining the future potential and development trends of optical imaging and optical metrology, an area of fast growth with numerous applications in nanotechnology and nanophysics. Written by the world's leading experts in the field, it fills the gap in the current literature by bridging the fields of optical imaging and metrology, and is the only up-to-date resource in terms of fundamental knowledge, basic concepts, methodologies, applications, and development trends.

  8. Optical Design for Biomedical Imaging

    CERN Document Server

    Liang, Rongguang

    2010-01-01

    Designing an efficient imaging system for biomedical optics requires a solid understanding of the special requirements of the optical systems for biomedical imaging and the optical components used in the systems. However, a lack of reference books on optical design (imaging and illumination) for biomedical imaging has led to some inefficient systems. This book fills the gap between biomedical optics and optical design by addressing the fundamentals of biomedical optics and optical engineering, and biomedical imaging systems. The first half provides a brief introduction to biomedical optics and

  9. Mapping breast cancer blood flow index, composition, and metabolism in a human subject using combined diffuse optical spectroscopic imaging and diffuse correlation spectroscopy

    Science.gov (United States)

    Yazdi, Hossein S.; O'Sullivan, Thomas D.; Leproux, Anais; Hill, Brian; Durkin, Amanda; Telep, Seraphim; Lam, Jesse; Yazdi, Siavash S.; Police, Alice M.; Carroll, Robert M.; Combs, Freddie J.; Strömberg, Tomas; Yodh, Arjun G.; Tromberg, Bruce J.

    2017-04-01

    Diffuse optical spectroscopic imaging (DOSI) and diffuse correlation spectroscopy (DCS) are model-based near-infrared (NIR) methods that measure tissue optical properties (broadband absorption, μa, and reduced scattering, μs‧) and blood flow (blood flow index, BFI), respectively. DOSI-derived μa values are used to determine composition by calculating the tissue concentration of oxy- and deoxyhemoglobin (HbO2, HbR), water, and lipid. We developed and evaluated a combined, coregistered DOSI/DCS handheld probe for mapping and imaging these parameters. We show that uncertainties of 0.3 mm-1 (37%) in μs‧ and 0.003 mm-1 (33%) in μa lead to ˜53% and 9% errors in BFI, respectively. DOSI/DCS imaging of a solid tissue-simulating flow phantom and a breast cancer patient reveals well-defined spatial distributions of BFI and composition that clearly delineates both the flow channel and the tumor. BFI reconstructed with DOSI-corrected μa and μs‧ values had a tumor/normal contrast of 2.7, 50% higher than the contrast using commonly assumed fixed optical properties. In conclusion, spatially coregistered imaging of DOSI and DCS enhances intrinsic tumor contrast and information content. This is particularly important for imaging diseased tissues where there are significant spatial variations in μa and μs‧ as well as potential uncoupling between flow and metabolism.

  10. Optical imaging. Expansion microscopy.

    Science.gov (United States)

    Chen, Fei; Tillberg, Paul W; Boyden, Edward S

    2015-01-30

    In optical microscopy, fine structural details are resolved by using refraction to magnify images of a specimen. We discovered that by synthesizing a swellable polymer network within a specimen, it can be physically expanded, resulting in physical magnification. By covalently anchoring specific labels located within the specimen directly to the polymer network, labels spaced closer than the optical diffraction limit can be isotropically separated and optically resolved, a process we call expansion microscopy (ExM). Thus, this process can be used to perform scalable superresolution microscopy with diffraction-limited microscopes. We demonstrate ExM with apparent ~70-nanometer lateral resolution in both cultured cells and brain tissue, performing three-color superresolution imaging of ~10(7) cubic micrometers of the mouse hippocampus with a conventional confocal microscope.

  11. Computer modeling of the optical properties and heating of spherical gold and silica-gold nanoparticles for laser combined imaging and photothermal treatment.

    Science.gov (United States)

    Pustovalov, V; Astafyeva, L; Jean, B

    2009-06-03

    Recently, several groups of investigators (Anderson, Halas, Zharov, El-Sayed and their co-workers (Pitsillides et al 2003 Biophys. J. 84 4023-31, Zharov et al 2003 Appl. Phys. Lett. 83 4897-9, Zharov et al 2004 Proc. SPIE 5319 291-9, Loo et al 2005 Nano Lett. 5 709-11, Gobin et al 2007 Nano Lett. 7 1929-34, Fu et al 2008 Nanotechnology 19 045103, Huang et al 2006 J. Am. Chem. Soc. 128 2115-20, Jain et al 2006 J. Phys. Chem. B 110 7238-48, Jain et al 2007 Nano Today 2 18-29)) demonstrated, through pioneering results, the great potential of laser thermal therapy of cells and tissues conjugated with gold nanoparticles. It was also proposed to use combined diagnostics and therapy on the basis of nanoparticle selection for achievement of efficient contrast for laser imaging applications, as well as for photothermal therapy. However, the current understanding of the relationship between optical properties (absorption, backscattering) of nanoparticles, the efficiency of nanoparticle heating and the possibility to use them for combined imaging and therapy is limited. Here, we report the results of computer modeling of optical absorption and backscattering properties and laser heating of gold and silica-gold spherical nanoparticles for laser combined imaging and photothermal treatment of cells and tissues conjugated with nanoparticles. The efficiencies of nanoparticle heating and backscattering by nanoparticles, depending upon their radii, structure and optical properties of the metal, were investigated. This paper focuses on the analysis and determination of appropriate ranges of nanoparticle sizes for the purposes of laser combined imaging and photothermal treatment. The possibility to use spherical gold and silica-gold nanoparticles in determined ranges of radii for these purposes for laser wavelengths 532 and 800 nm is investigated.

  12. Retinal Optical Coherence Tomography Imaging

    Science.gov (United States)

    Drexler, Wolfgang; Fujimoto, James G.

    The eye is essentially transparent, transmitting light with only minimal optical attenuation and scattering providing easy optical access to the anterior segment as well as the retina. For this reason, ophthalmic and especially retinal imaging has been not only the first but also most successful clinical application for optical coherence tomography (OCT). This chapter focuses on the development of OCT technology for retinal imaging. OCT has significantly improved the potential for early diagnosis, understanding of retinal disease pathogenesis, as well as monitoring disease progression and response to therapy. Development of ultrabroad bandwidth light sources and high-speed detection techniques has enabled significant improvements in ophthalmic OCT imaging performance, demonstrating the potential of three-dimensional, ultrahigh-resolution OCT (UHR OCT) to perform noninvasive optical biopsy of the living human retina, i.e., the in vivo visualization of microstructural, intraretinal morphology in situ approaching the resolution of conventional histopathology. Significant improvements in axial resolution and speed not only enable three-dimensional rendering of retinal volumes but also high-definition, two-dimensional tomograms, topographic thickness maps of all major intraretinal layers, as well as volumetric quantification of pathologic intraretinal changes. These advances in OCT technology have also been successfully applied in several animal models of retinal pathologies. The development of light sources emitting at alternative wavelengths, e.g., around #1,060 nm, not only enabled three-dimensional OCT imaging with enhanced choroidal visualization but also improved OCT performance in cataract patients due to reduced scattering losses in this wavelength region. Adaptive optics using deformable mirror technology, with unique high stroke to correct higher-order ocular aberrations, with specially designed optics to compensate chromatic aberration of the human eye, in

  13. Adaptive-optics SLO imaging combined with widefield OCT and SLO enables precise 3D localization of fluorescent cells in the mouse retina.

    Science.gov (United States)

    Zawadzki, Robert J; Zhang, Pengfei; Zam, Azhar; Miller, Eric B; Goswami, Mayank; Wang, Xinlei; Jonnal, Ravi S; Lee, Sang-Hyuck; Kim, Dae Yu; Flannery, John G; Werner, John S; Burns, Marie E; Pugh, Edward N

    2015-06-01

    Adaptive optics scanning laser ophthalmoscopy (AO-SLO) has recently been used to achieve exquisite subcellular resolution imaging of the mouse retina. Wavefront sensing-based AO typically restricts the field of view to a few degrees of visual angle. As a consequence the relationship between AO-SLO data and larger scale retinal structures and cellular patterns can be difficult to assess. The retinal vasculature affords a large-scale 3D map on which cells and structures can be located during in vivo imaging. Phase-variance OCT (pv-OCT) can efficiently image the vasculature with near-infrared light in a label-free manner, allowing 3D vascular reconstruction with high precision. We combined widefield pv-OCT and SLO imaging with AO-SLO reflection and fluorescence imaging to localize two types of fluorescent cells within the retinal layers: GFP-expressing microglia, the resident macrophages of the retina, and GFP-expressing cone photoreceptor cells. We describe in detail a reflective afocal AO-SLO retinal imaging system designed for high resolution retinal imaging in mice. The optical performance of this instrument is compared to other state-of-the-art AO-based mouse retinal imaging systems. The spatial and temporal resolution of the new AO instrumentation was characterized with angiography of retinal capillaries, including blood-flow velocity analysis. Depth-resolved AO-SLO fluorescent images of microglia and cone photoreceptors are visualized in parallel with 469 nm and 663 nm reflectance images of the microvasculature and other structures. Additional applications of the new instrumentation are discussed.

  14. Incorporating uncertanity into Markov random field classification with the combine use of optical and SAR images and aduptive fuzzy mean vector

    Science.gov (United States)

    Welikanna, D. R.; Tamura, M.; Susaki, J.

    2014-09-01

    A Markov Random Field (MRF) model accounting for the classification uncertainty using multisource satellite images and an adaptive fuzzy class mean vector is proposed in this study. The work also highlights the initialization of the class values for an MRF based classification for synthetic aperture radar (SAR) images using optical data. The model uses the contextual information from the optical image pixels and the SAR pixel intensity with corresponding fuzzy grade of memberships respectively, in the classification mechanism. Sub pixel class fractions estimated using Singular Value Decomposition (SVD) from the optical image initializes the class arrangement for the MRF process. Pair-site interactions of the pixels are used to model the prior energy from the initial class arrangement. Fuzzy class mean vector from the SAR intensity pixels is calculated using Fuzzy C-means (FCM) partitioning. Conditional probability for each class was determined by a Gamma distribution for the SAR image. Simulated annealing (SA) to minimize the global energy was executed using a logarithmic and power-law combined annealing schedule. Proposed technique was tested using an Advanced Land Observation Satellite (ALOS) phased array type L-band SAR (PALSAR) and Advanced Visible and Near-Infrared Radiometer-2 (AVNIR-2) data set over a disaster effected urban region in Japan. Proposed method and the conventional MRF results were evaluated with neural network (NN) and support vector machine (SVM) based classifications. The results suggest the possible integration of an adaptive fuzzy class mean vector and multisource data is promising for imprecise class discrimination using a MRF based classification.

  15. Fiber optic sensing and imaging

    CERN Document Server

    2013-01-01

    This book is designed to highlight the basic principles of fiber optic imaging and sensing devices. The editor has organized the book to provide the reader with a solid foundation in fiber optic imaging and sensing devices. It begins with an introductory chapter that starts from Maxwell’s equations and ends with the derivation of the basic optical fiber characteristic equations and solutions (i.e. fiber modes). Chapter 2 reviews most common fiber optic interferometric devices and Chapter 3 discusses the basics of fiber optic imagers with emphasis on fiber optic confocal microscope. The fiber optic interferometric sensors are discussed in detail in chapter 4 and 5. Chapter 6 covers optical coherence tomography and goes into the details of signal processing and systems level approach of the real-time OCT implementation. Also useful forms of device characteristic equations are provided so that this book can be used as a reference for scientists and engineers in the optics and related fields.

  16. Optical image encryption based on diffractive imaging.

    Science.gov (United States)

    Chen, Wen; Chen, Xudong; Sheppard, Colin J R

    2010-11-15

    In this Letter, we propose a method for optical image encryption based on diffractive imaging. An optical multiple random phase mask encoding system is applied, and one of the phase-only masks is selected and laterally translated along a preset direction during the encryption process. For image decryption, a phase retrieval algorithm is proposed to extract a high-quality plaintext. The feasibility and effectiveness of the proposed method are demonstrated by numerical results. The proposed method can provide a new strategy instead of conventional interference methods, and it may open up a new research perspective for optical image encryption.

  17. Use of combined polarization-sensitive optical coherence tomography and Mueller matrix imaging for the polarimetric characterization of excised biological tissue

    Science.gov (United States)

    Chue-Sang, Joseph; Bai, Yuqiang; Stoff, Susan; Straton, David; Ramaswamy, Sharan; Ramella-Roman, Jessica C.

    2016-07-01

    Mueller matrix polarimetry and polarization-sensitive optical coherence tomography (PS-OCT) are two emerging techniques utilized in the assessment of tissue anisotropy. While PS-OCT can provide cross-sectional images of local tissue birefringence through its polarimetric sensitivity, Mueller matrix polarimetry can be used to measure bulk polarimetric properties such as depolarization, diattenuation, and retardance. To this day true quantification of PS-OCT data can be elusive, partly due to the reliance on inverse models for the characterization of tissue birefringence and the influence of instrumentation noise. Similarly for Mueller matrix polarimetry, calculation of retardance or depolarization may be influenced by tissue heterogeneities that could be monitored with PS-OCT. Here, we propose an instrument that combines Mueller matrix polarimetry and PS-OCT. Through the co-registration of the two systems, we aim at achieving a better understanding of both modalities.

  18. Optical medical imaging: from glass to man

    Science.gov (United States)

    Bradley, Mark

    2016-11-01

    A formidable challenge in modern respiratory healthcare is the accurate and timely diagnosis of lung infection and inflammation. The EPSRC Interdisciplinary Research Collaboration (IRC) `Proteus' seeks to address this challenge by developing an optical fibre based healthcare technology platform that combines physiological sensing with multiplexed optical molecular imaging. This technology will enable in situ measurements deep in the human lung allowing the assessment of tissue function and characterization of the unique signatures of pulmonary disease and is illustrated here with our in-man application of Optical Imaging SmartProbes and our first device Versicolour.

  19. Advanced Imaging Optics Utilizing Wavefront Coding.

    Energy Technology Data Exchange (ETDEWEB)

    Scrymgeour, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Boye, Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Adelsberger, Kathleen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-01

    Image processing offers a potential to simplify an optical system by shifting some of the imaging burden from lenses to the more cost effective electronics. Wavefront coding using a cubic phase plate combined with image processing can extend the system's depth of focus, reducing many of the focus-related aberrations as well as material related chromatic aberrations. However, the optimal design process and physical limitations of wavefront coding systems with respect to first-order optical parameters and noise are not well documented. We examined image quality of simulated and experimental wavefront coded images before and after reconstruction in the presence of noise. Challenges in the implementation of cubic phase in an optical system are discussed. In particular, we found that limitations must be placed on system noise, aperture, field of view and bandwidth to develop a robust wavefront coded system.

  20. Image processing for optical mapping.

    Science.gov (United States)

    Ravindran, Prabu; Gupta, Aditya

    2015-01-01

    Optical Mapping is an established single-molecule, whole-genome analysis system, which has been used to gain a comprehensive understanding of genomic structure and to study structural variation of complex genomes. A critical component of Optical Mapping system is the image processing module, which extracts single molecule restriction maps from image datasets of immobilized, restriction digested and fluorescently stained large DNA molecules. In this review, we describe robust and efficient image processing techniques to process these massive datasets and extract accurate restriction maps in the presence of noise, ambiguity and confounding artifacts. We also highlight a few applications of the Optical Mapping system.

  1. Optical imaging probes in oncology.

    Science.gov (United States)

    Martelli, Cristina; Lo Dico, Alessia; Diceglie, Cecilia; Lucignani, Giovanni; Ottobrini, Luisa

    2016-07-26

    Cancer is a complex disease, characterized by alteration of different physiological molecular processes and cellular features. Keeping this in mind, the possibility of early identification and detection of specific tumor biomarkers by non-invasive approaches could improve early diagnosis and patient management.Different molecular imaging procedures provide powerful tools for detection and non-invasive characterization of oncological lesions. Clinical studies are mainly based on the use of computed tomography, nuclear-based imaging techniques and magnetic resonance imaging. Preclinical imaging in small animal models entails the use of dedicated instruments, and beyond the already cited imaging techniques, it includes also optical imaging studies. Optical imaging strategies are based on the use of luminescent or fluorescent reporter genes or injectable fluorescent or luminescent probes that provide the possibility to study tumor features even by means of fluorescence and luminescence imaging. Currently, most of these probes are used only in animal models, but the possibility of applying some of them also in the clinics is under evaluation.The importance of tumor imaging, the ease of use of optical imaging instruments, the commercial availability of a wide range of probes as well as the continuous description of newly developed probes, demonstrate the significance of these applications. The aim of this review is providing a complete description of the possible optical imaging procedures available for the non-invasive assessment of tumor features in oncological murine models. In particular, the characteristics of both commercially available and newly developed probes will be outlined and discussed.

  2. Optical image processing by using a photorefractive spatial soliton waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Bao-Lai, E-mail: liangbaolai@gmail.com [College of Physics Science & Technology, Hebei University, Baoding 071002 (China); Wang, Ying; Zhang, Su-Heng; Guo, Qing-Lin; Wang, Shu-Fang; Fu, Guang-Sheng [College of Physics Science & Technology, Hebei University, Baoding 071002 (China); Simmonds, Paul J. [Department of Physics and Micron School of Materials Science & Engineering, Boise State University, Boise, ID 83725 (United States); Wang, Zhao-Qi [Institute of Modern Optics, Nankai University, Tianjin 300071 (China)

    2017-04-04

    By combining the photorefractive spatial soliton waveguide of a Ce:SBN crystal with a coherent 4-f system we are able to manipulate the spatial frequencies of an input optical image to perform edge-enhancement and direct component enhancement operations. Theoretical analysis of this optical image processor is presented to interpret the experimental observations. This work provides an approach for optical image processing by using photorefractive spatial solitons. - Highlights: • A coherent 4-f system with the spatial soliton waveguide as spatial frequency filter. • Manipulate the spatial frequencies of an input optical image. • Achieve edge-enhancement and direct component enhancement operations of an optical image.

  3. Optical and digital image processing

    CERN Document Server

    Cristobal, Gabriel; Thienpont, Hugo

    2011-01-01

    In recent years, Moore's law has fostered the steady growth of the field of digital image processing, though the computational complexity remains a problem for most of the digital image processing applications. In parallel, the research domain of optical image processing has matured, potentially bypassing the problems digital approaches were suffering and bringing new applications. The advancement of technology calls for applications and knowledge at the intersection of both areas but there is a clear knowledge gap between the digital signal processing and the optical processing communities. T

  4. Imaging of the optic nerve

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Minerva [Head and Neck and Maxillofacial Radiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland)], E-mail: minerva.becker@hcuge.ch; Masterson, Karen [Head and Neck and Maxillofacial Radiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Delavelle, Jacqueline [Neuroradiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Viallon, Magalie [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Vargas, Maria-Isabel [Neuroradiology, Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland); Becker, Christoph D. [Department of Radiology, Geneva University Hospital, Rue Gabrielle-Perret-Gentil 4, CH - 1211 Geneva 14 (Switzerland)

    2010-05-15

    This article provides an overview of the imaging findings of diseases affecting the optic nerve with special emphasis on clinical-radiological correlation and on the latest technical developments in MR imaging and CT. The review deals with congenital malformations, tumors, toxic/nutritional and degenerative entities, inflammatory and infectious diseases, compressive neuropathy, vascular conditions and trauma involving the optic nerve from its ocular segment to the chiasm. The implications of imaging findings on patient management and outcome and the importance of performing high-resolution tailored examinations adapted to the clinical situation are discussed.

  5. Micro-optics for imaging.

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Robert R.

    2010-09-01

    This project investigates the fundamental imaging capability of an optic with a physical thickness substantially less than 1 mm. The analysis assumes that post-processing can overcome certain restrictions such as detector pixel size and image degradation due to aberrations. A first order optical analysis quickly reveals the limitations of even an ideal thin lens to provide sufficient image resolution and provides the justification for pursuing an annular design. Some straightforward examples clearly show the potential of this approach. The tradeoffs associated with annular designs, specifically field of view limitations and reduced mid-level spatial frequencies, are discussed and their impact on the imaging performance evaluated using several imaging examples. Additionally, issues such as detector acceptance angle and the need to balance aberrations with resolution are included in the analysis. With these restrictions, the final results present an excellent approximation of the expected performance of the lens designs presented.

  6. Optical image processing by using a photorefractive spatial soliton waveguide

    Science.gov (United States)

    Liang, Bao-Lai; Wang, Ying; Zhang, Su-Heng; Guo, Qing-Lin; Wang, Shu-Fang; Fu, Guang-Sheng; Simmonds, Paul J.; Wang, Zhao-Qi

    2017-04-01

    By combining the photorefractive spatial soliton waveguide of a Ce:SBN crystal with a coherent 4-f system we are able to manipulate the spatial frequencies of an input optical image to perform edge-enhancement and direct component enhancement operations. Theoretical analysis of this optical image processor is presented to interpret the experimental observations. This work provides an approach for optical image processing by using photorefractive spatial solitons.

  7. Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy

    OpenAIRE

    Fujimoto, James G.; Pitris, Costas; Boppart, Stephen A.; Brezinski, Mark E.

    2000-01-01

    Optical coherence tomography (OCT) is an emerging technology for performing high-resolution cross-sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cross-sectional images of tissue structure on the micron scale in situ and in real time. Using OCT in combination with catheters and endoscopes enables high-resolution intraluminal imaging of organ systems. OCT can function as a type of optical biopsy and is a powerful imaging te...

  8. Simulations of optical microscope images

    Science.gov (United States)

    Germer, Thomas A.; Marx, Egon

    2006-03-01

    The resolution of an optical microscope is limited by the optical wavelengths used. However, there is no fundamental limit to the sensitivity of a microscope to small differences in any of a feature's dimensions. That is, those limits are determined by such things as the sensitivity of the detector array, the quality of the optical system, and the stability of the light source. The potential for using this nearly unbounded sensitivity has sparked interest in extending optical microscopy to the characterization of sub-wavelength structures created by photolithography and using that characterization for process control. In this paper, an analysis of the imaging of a semiconductor grating structure with an optical microscope will be presented. The analysis includes the effects of partial coherence in the illumination system, aberrations of both the illumination and the collection optics, non-uniformities in the illumination, and polarization. It can thus model just about any illumination configuration imaginable, including Koehler illumination, focused (confocal) illumination, or dark-field illumination. By propagating Jones matrices throughout the system, polarization control at the back focal planes of both illumination and collection can be investigated. Given a detailed characterization of the microscope (including aberrations), images can be calculated and compared to real data, allowing details of the grating structure to be determined, in a manner similar to that found in scatterometry.

  9. Forecasting of cereals yields in a semi-arid area using the agrometeorological model «SAFY» combined to optical SPOT/HRV images

    Science.gov (United States)

    Chahbi, Aicha; Zribi, Mehrez; Lili-Chabaane, Zohra; Mougenot, Bernard

    2015-10-01

    In semi-arid areas, an operational grain yield forecasting system, which could help decision-makers to plan annual imports, is needed. It can be challenging to monitor the crop canopy and production capacity of plants, especially cereals. Many models, based on the use of remote sensing or agro-meteorological models, have been developed to estimate the biomass and grain yield of cereals. Remote sensing has demonstrated its strong potential for the monitoring of the vegetation's dynamics and temporal variations. Through the use of a rich database, acquired over a period of two years for more than 60 test fields, and from 20 optical satellite SPOT/HRV images, the aim of the present study is to evaluate the feasibility of two approaches to estimate the dynamics and yields of cereals in the context of semi-arid, low productivity regions in North Africa. The first approach is based on the application of the semi-empirical growth model SAFY "Simple Algorithm For Yield estimation", developed to simulate the dynamics of the leaf area index and the grain yield, at the field scale. The model is able to reproduce the time evolution of the LAI of all fields. However, the yields are under-estimated. Therefore, we developed a new approach to improve the SAFY model. The grain yield is function of LAI area in the growth period between 25 March and 5 April. This approach is robust, the measured and estimated grain yield are well correlated. Finally, this model is used in combination with remotely sensed LAI measurements to estimate yield for the entire studied site.

  10. Biomedical Optical Imaging Technologies Design and Applications

    CERN Document Server

    2013-01-01

    This book provides an introduction to design of biomedical optical imaging technologies and their applications. The main topics include: fluorescence imaging, confocal imaging, micro-endoscope, polarization imaging, hyperspectral imaging, OCT imaging, multimodal imaging and spectroscopic systems. Each chapter is written by the world leaders of the respective fields, and will cover: principles and limitations of optical imaging technology, system design and practical implementation for one or two specific applications, including design guidelines, system configuration, optical design, component requirements and selection, system optimization and design examples, recent advances and applications in biomedical researches and clinical imaging. This book serves as a reference for students and researchers in optics and biomedical engineering.

  11. Beam combination schemes and technologies for the Planet Formation Imager

    Science.gov (United States)

    Minardi, Stefano; Lacour, Sylvestre; Berger, Jean-Philippe; Labadie, Lucas; Thomson, Robert R.; Haniff, Chris; Ireland, Michael

    2016-08-01

    The Planet Formation Imager initiative aims at developing the next generation large scale facility for imaging astronomical optical interferometry operating in the mid-infrared. Here we report on the progress of the Planet Formation Imager Technical Working Group on the beam-combination instruments. We will discuss various available options for the science and fringe-tracker beam combination instruments, ranging from direct imaging, to non-redundant fiber arrays, to integrated optics solutions. Besides considering basic characteristics of the schemes, we will investigate the maturity of the available technological platforms at near- and mid-infrared wavelengths.

  12. Fluorescence imaging spectrometer optical design

    Science.gov (United States)

    Taiti, A.; Coppo, P.; Battistelli, E.

    2015-09-01

    The optical design of the FLuORescence Imaging Spectrometer (FLORIS) studied for the Fluorescence Explorer (FLEX) mission is discussed. FLEX is a candidate for the ESA's 8th Earth Explorer opportunity mission. FLORIS is a pushbroom hyperspectral imager foreseen to be embarked on board of a medium size satellite, flying in tandem with Sentinel-3 in a Sun synchronous orbit at a height of about 815 km. FLORIS will observe the vegetation fluorescence and reflectance within a spectral range between 500 and 780 nm. Multi-frames acquisitions on matrix detectors during the satellite movement will allow the production of 2D Earth scene images in two different spectral channels, called HR and LR with spectral resolution of 0.3 and 2 nm respectively. A common fore optics is foreseen to enhance by design the spatial co-registration between the two spectral channels, which have the same ground spatial sampling (300 m) and swath (150 km). An overlapped spectral range between the two channels is also introduced to simplify the spectral coregistration. A compact opto-mechanical solution with all spherical and plane optical elements is proposed, and the most significant design rationales are described. The instrument optical architecture foresees a dual Babinet scrambler, a dioptric telescope and two grating spectrometers (HR and LR), each consisting of a modified Offner configuration. The developed design is robust, stable vs temperature, easy to align, showing very high optical quality along the whole field of view. The system gives also excellent correction for transverse chromatic aberration and distortions (keystone and smile).

  13. Optical Waveguide Sensing and Imaging

    CERN Document Server

    Bock, Wojtek J; Tanev, Stoyan

    2008-01-01

    The book explores various aspects of existing and emerging fiber and waveguide optics sensing and imaging technologies including recent advances in nanobiophotonics. The focus is both on fundamental and applied research as well as on applications in civil engineering, biomedical sciences, environment, security and defence. The main goal of the multi-disciplinarry team of Editors was to provide an useful reference of state-of-the-art overviews covering a variety of complementary topics on the interface of engineering and biomedical sciences.

  14. Advances in Optical Spectroscopy and Imaging of Breast Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Demos, S; Vogel, A J; Gandjbakhche, A H

    2006-01-03

    A review is presented of recent advances in optical imaging and spectroscopy and the use of light for addressing breast cancer issues. Spectroscopic techniques offer the means to characterize tissue components and obtain functional information in real time. Three-dimensional optical imaging of the breast using various illumination and signal collection schemes in combination with image reconstruction algorithms may provide a new tool for cancer detection and monitoring of treatment.

  15. Combined multi-modal photoacoustic tomography, optical coherence tomography (OCT) and OCT angiography system with an articulated probe for in vivo human skin structure and vasculature imaging.

    Science.gov (United States)

    Liu, Mengyang; Chen, Zhe; Zabihian, Behrooz; Sinz, Christoph; Zhang, Edward; Beard, Paul C; Ginner, Laurin; Hoover, Erich; Minneman, Micheal P; Leitgeb, Rainer A; Kittler, Harald; Drexler, Wolfgang

    2016-09-01

    Cutaneous blood flow accounts for approximately 5% of cardiac output in human and plays a key role in a number of a physiological and pathological processes. We show for the first time a multi-modal photoacoustic tomography (PAT), optical coherence tomography (OCT) and OCT angiography system with an articulated probe to extract human cutaneous vasculature in vivo in various skin regions. OCT angiography supplements the microvasculature which PAT alone is unable to provide. Co-registered volumes for vessel network is further embedded in the morphologic image provided by OCT. This multi-modal system is therefore demonstrated as a valuable tool for comprehensive non-invasive human skin vasculature and morphology imaging in vivo.

  16. Combined multi-modal photoacoustic tomography, optical coherence tomography (OCT) and OCT angiography system with an articulated probe for in vivo human skin structure and vasculature imaging

    Science.gov (United States)

    Liu, Mengyang; Chen, Zhe; Zabihian, Behrooz; Sinz, Christoph; Zhang, Edward; Beard, Paul C.; Ginner, Laurin; Hoover, Erich; Minneman, Micheal P.; Leitgeb, Rainer A.; Kittler, Harald; Drexler, Wolfgang

    2016-01-01

    Cutaneous blood flow accounts for approximately 5% of cardiac output in human and plays a key role in a number of a physiological and pathological processes. We show for the first time a multi-modal photoacoustic tomography (PAT), optical coherence tomography (OCT) and OCT angiography system with an articulated probe to extract human cutaneous vasculature in vivo in various skin regions. OCT angiography supplements the microvasculature which PAT alone is unable to provide. Co-registered volumes for vessel network is further embedded in the morphologic image provided by OCT. This multi-modal system is therefore demonstrated as a valuable tool for comprehensive non-invasive human skin vasculature and morphology imaging in vivo. PMID:27699106

  17. LINC-NIRVANA: cryogenic optics for diffraction limited beam combination

    Science.gov (United States)

    Bizenberger, Peter; Baumeister, Harald; Herbst, Tom; Zhang, Xianyu

    2012-09-01

    LINC-NIRVANA is an interferometric imaging camera, which combines the two 8.4 m telescopes of the Large Binocular Telescope (LBT). The instrument operates in the wavelength range from 1.1 μm to 2.4 μm, covering the J, H and K-band, respectively. The beam combining camera (NIRCS) offers the possibility to achieve diffraction limited images with the special resolution of a 23 m telescope. The optics are designed to deliver a 10 arcsec × 10 arcsec field of view with 5 mas resolution. In this paper we describe the evolution of the cryogenic optics, from design and manufacturing to verification. Including the argumentation for decisions we made in order to present a sort of guideline for large cryo-optics. We also present the alignment and testing strategies at a detailed level.

  18. Encoded diffractive optics for full-spectrum computational imaging

    Science.gov (United States)

    Heide, Felix; Fu, Qiang; Peng, Yifan; Heidrich, Wolfgang

    2016-09-01

    Diffractive optical elements can be realized as ultra-thin plates that offer significantly reduced footprint and weight compared to refractive elements. However, such elements introduce severe chromatic aberrations and are not variable, unless used in combination with other elements in a larger, reconfigurable optical system. We introduce numerically optimized encoded phase masks in which different optical parameters such as focus or zoom can be accessed through changes in the mechanical alignment of a ultra-thin stack of two or more masks. Our encoded diffractive designs are combined with a new computational approach for self-calibrating imaging (blind deconvolution) that can restore high-quality images several orders of magnitude faster than the state of the art without pre-calibration of the optical system. This co-design of optics and computation enables tunable, full-spectrum imaging using thin diffractive optics.

  19. Encoded diffractive optics for full-spectrum computational imaging

    KAUST Repository

    Heide, Felix

    2016-09-16

    Diffractive optical elements can be realized as ultra-thin plates that offer significantly reduced footprint and weight compared to refractive elements. However, such elements introduce severe chromatic aberrations and are not variable, unless used in combination with other elements in a larger, reconfigurable optical system. We introduce numerically optimized encoded phase masks in which different optical parameters such as focus or zoom can be accessed through changes in the mechanical alignment of a ultra-thin stack of two or more masks. Our encoded diffractive designs are combined with a new computational approach for self-calibrating imaging (blind deconvolution) that can restore high-quality images several orders of magnitude faster than the state of the art without pre-calibration of the optical system. This co-design of optics and computation enables tunable, full-spectrum imaging using thin diffractive optics.

  20. Optomechatronics for Biomedical Optical Imaging: An Overview

    OpenAIRE

    Cho Hyungsuck

    2015-01-01

    The use of optomechatronic technology, particularly in biomedical optical imaging, is becoming pronounced and ever increasing due to its synergistic effect of the integration of optics and mechatronics. The background of this trend is that the biomedical optical imaging for example in-vivo imaging related to retraction of tissues, diagnosis, and surgical operations have a variety of challenges due to complexity in internal structure and properties of biological body and the resulting optical ...

  1. Optomechatronics for Biomedical Optical Imaging: An Overview

    Directory of Open Access Journals (Sweden)

    Cho Hyungsuck

    2015-01-01

    Full Text Available The use of optomechatronic technology, particularly in biomedical optical imaging, is becoming pronounced and ever increasing due to its synergistic effect of the integration of optics and mechatronics. The background of this trend is that the biomedical optical imaging for example in-vivo imaging related to retraction of tissues, diagnosis, and surgical operations have a variety of challenges due to complexity in internal structure and properties of biological body and the resulting optical phenomena. This paper addresses the technical issues related to tissue imaging, visualization of interior surfaces of organs, laparoscopic and endoscopic imaging and imaging of neuronal activities and structures. Within such problem domains the paper overviews the states of the art technology focused on how optical components are fused together with those of mechatronics to create the functionalities required for the imaging systems. Future perspective of the optical imaging in biomedical field is presented in short.

  2. Adaptive optics and phase diversity imaging for responsive space applications.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Mark William; Wick, David Victor

    2004-11-01

    The combination of phase diversity and adaptive optics offers great flexibility. Phase diverse images can be used to diagnose aberrations and then provide feedback control to the optics to correct the aberrations. Alternatively, phase diversity can be used to partially compensate for aberrations during post-detection image processing. The adaptive optic can produce simple defocus or more complex types of phase diversity. This report presents an analysis, based on numerical simulations, of the efficiency of different modes of phase diversity with respect to compensating for specific aberrations during post-processing. It also comments on the efficiency of post-processing versus direct aberration correction. The construction of a bench top optical system that uses a membrane mirror as an active optic is described. The results of characterization tests performed on the bench top optical system are presented. The work described in this report was conducted to explore the use of adaptive optics and phase diversity imaging for responsive space applications.

  3. Optical and digital microscopic imaging techniques and applications in pathology.

    Science.gov (United States)

    Chen, Xiaodong; Zheng, Bin; Liu, Hong

    2011-01-01

    The conventional optical microscope has been the primary tool in assisting pathological examinations. The modern digital pathology combines the power of microscopy, electronic detection, and computerized analysis. It enables cellular-, molecular-, and genetic-imaging at high efficiency and accuracy to facilitate clinical screening and diagnosis. This paper first reviews the fundamental concepts of microscopic imaging and introduces the technical features and associated clinical applications of optical microscopes, electron microscopes, scanning tunnel microscopes, and fluorescence microscopes. The interface of microscopy with digital image acquisition methods is discussed. The recent developments and future perspectives of contemporary microscopic imaging techniques such as three-dimensional and in vivo imaging are analyzed for their clinical potentials.

  4. Optical-digital hybrid image search system in cloud environment

    Science.gov (United States)

    Ikeda, Kanami; Kodate, Kashiko; Watanabe, Eriko

    2016-09-01

    To improve the versatility and usability of optical correlators, we developed an optical-digital hybrid image search system consisting of digital servers and an optical correlator that can be used to perform image searches in the cloud environment via a web browser. This hybrid system employs a simple method to obtain correlation signals and has a distributed network design. The correlation signals are acquired by using an encoder timing signal generated by a rotating disk, and the distributed network design facilitates the replacement and combination of the digital correlation server and the optical correlator.

  5. Computational imaging using lightweight diffractive-refractive optics

    KAUST Repository

    Peng, Yifan

    2015-11-23

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  6. Computational imaging using lightweight diffractive-refractive optics.

    Science.gov (United States)

    Peng, Yifan; Fu, Qiang; Amata, Hadi; Su, Shuochen; Heide, Felix; Heidrich, Wolfgang

    2015-11-30

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  7. Optically-induced-potential-based image encryption.

    Science.gov (United States)

    Chen, Bing-Chu; Wang, He-Zhou

    2011-11-07

    We present a technique of nonlinear image encryption by use of virtual optics. The image to be encrypted is superposed on a random intensity image. And this superposed image propagates through a nonlinear medium and a 4-f system with single phase key. The image is encrypted to a stationary white noise. The decryption process is sensitive to the parameters of the encryption system and the phase key in 4-f system. This sensitivity makes attackers hard to access the phase key. In nonlinear medium, optically-induced potentials, which depend on intensity of optical wave, make the superposition principle frustrated. This nonlinearity based on optically induced potentials highly improves the secrecy level of image encryption. Resistance against attacks based on the phase retrieval technique proves that it has the high secrecy level. This nonlinear image encryption based on optically induced potentials is proposed and demonstrated for the first time.

  8. Plenoptic microscope based on laser optical feedback imaging (LOFI)

    CERN Document Server

    Glastre, W; Jacquin, O; de Chatellus, H Guillet; Lacot, E

    2015-01-01

    We present an overview of the performances of a plenoptic microscope which combines the high sensitivity of a laser optical feedback imaging setup , the high resolution of optical synthetic aperture and a shot noise limited signal to noise ratio by using acoustic photon tagging. By using an adapted phase filtering, this microscope allows phase drift correction and numerical aberration compensation (defocusing, coma, astigmatism ...). This new kind of microscope seems to be well adapted to make deep imaging through scattering and heterogeneous media.

  9. Section on High Resolution Optical Imaging (HROI)

    Data.gov (United States)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  10. Reticle defect sizing of optical proximity correction defects using SEM imaging and image analysis techniques

    Science.gov (United States)

    Zurbrick, Larry S.; Wang, Lantian; Konicek, Paul; Laird, Ellen R.

    2000-07-01

    Sizing of programmed defects on optical proximity correction (OPC) feature sis addressed using high resolution scanning electron microscope (SEM) images and image analysis techniques. A comparison and analysis of different sizing methods is made. This paper addresses the issues of OPC defect definition and discusses the experimental measurement results obtained by SEM in combination with image analysis techniques.

  11. Synthesis of Disparate Optical Imaging Data for Space Domain Awareness

    CERN Document Server

    Schneider, Michael D

    2016-01-01

    We present a Bayesian algorithm to combine optical imaging of unresolved objects from distinct epochs and observation platforms for orbit determination and tracking. By propagating the non-Gaussian uncertainties we are able to optimally combine imaging of arbitrary signal-to-noise ratios, allowing the integration of data from low-cost sensors. Our Bayesian approach to image characterization also allows large compression of imaging data without loss of statistical information. With a computationally efficient algorithm to combine multiple observation epochs and multiple telescopes, we show statistically optimal orbit inferences.

  12. A dual-modal retinal imaging system with adaptive optics.

    Science.gov (United States)

    Meadway, Alexander; Girkin, Christopher A; Zhang, Yuhua

    2013-12-02

    An adaptive optics scanning laser ophthalmoscope (AO-SLO) is adapted to provide optical coherence tomography (OCT) imaging. The AO-SLO function is unchanged. The system uses the same light source, scanning optics, and adaptive optics in both imaging modes. The result is a dual-modal system that can acquire retinal images in both en face and cross-section planes at the single cell level. A new spectral shaping method is developed to reduce the large sidelobes in the coherence profile of the OCT imaging when a non-ideal source is used with a minimal introduction of noise. The technique uses a combination of two existing digital techniques. The thickness and position of the traditionally named inner segment/outer segment junction are measured from individual photoreceptors. In-vivo images of healthy and diseased human retinas are demonstrated.

  13. Computer Aided Interpretation Approach for Optical Tomographic Images

    CERN Document Server

    Klose, Christian D; Netz, Uwe; Beuthan, Juergen; Hielscher, Andreas H

    2010-01-01

    A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) of human finger joints in optical tomographic images. The image interpretation method employs a multi-variate signal detection analysis aided by a machine learning classification algorithm, called Self-Organizing Mapping (SOM). Unlike in previous studies, this allows for combining multiple physical image parameters, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging and inspection of optical tomographic images), were used as "ground truth"-benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities while...

  14. The GRAVITY integrated optics beam combination

    Science.gov (United States)

    Jocou, L.; Perraut, K.; Nolot, A.; Berger, J. P.; Moulin, T.; Labeye, P.; Lacour, S.; Perrin, G.; Lebouquin, J. B.; Bartko, H.; Thiel, M.; Eisenhauer, F.

    2010-07-01

    Gravity is a 2nd generation interferometric instrument for VLTI. It will combine 4 telescopes in dual feed in the K band to study general relativity effects around the Galactic Center black hole. The concept of Gravity is based on two equivalent beam combiner instruments: the scientific one fed by the science target (Sgr A*) and the fringe tracker fed by a bright reference star (See Gillessen et al.1). Both beam combination instruments are based on silica on silicon integrated optics (IO) component glued to fluoride glass fiber array. The beam combiners are implemented in a cryogenic vessel cooled at 200°K and back-illuminated by a high power laser used for metrology (Bartko et al.2). This paper is dedicated to the description of the development of the integrated beam combiner assembly.

  15. Monitoring hypoxia induced changes in cochlear blood flow and hemoglobin concentration using a combined dual-wavelength laser speckle contrast imaging and Doppler optical microangiography system.

    Directory of Open Access Journals (Sweden)

    Roberto Reif

    Full Text Available A synchronized dual-wavelength laser speckle contrast imaging (DWLSCI system and a Doppler optical microangiography (DOMAG system was developed to determine several ischemic parameters in the cochlea due to a systemic hypoxic challenge. DWLSCI can obtain two-dimensional data, and was used to determine the relative changes in cochlear blood flow, and change in the concentrations of oxyhemoglobin (HbO, deoxyhemoglobin (Hb and total hemoglobin (HbT in mice. DOMAG can obtain three-dimensional data, and was used to determine the changes in cochlear blood flow with single vessel resolution. It was demonstrated that during a hypoxic challenge there was an increase in the concentrations of Hb, a decrease in the concentrations of HbO and cochlear blood flow, and a slight decrease in the concentration of HbT. Also, the rate of change in the concentrations of Hb and HbO was quantified during and after the hypoxic challenge. The ability to simultaneously measure these ischemic parameters with high spatio-temporal resolution will allow the detailed quantitative analysis of several hearing disorders, and will be useful for diagnosing and developing treatments.

  16. Automated interpretation of optic nerve images: a data mining framework for glaucoma diagnostic support.

    Science.gov (United States)

    Abidi, Syed S R; Artes, Paul H; Yun, Sanjan; Yu, Jin

    2007-01-01

    Confocal Scanning Laser Tomography (CSLT) techniques capture high-quality images of the optic disc (the retinal region where the optic nerve exits the eye) that are used in the diagnosis and monitoring of glaucoma. We present a hybrid framework, combining image processing and data mining methods, to support the interpretation of CSLT optic nerve images. Our framework features (a) Zernike moment methods to derive shape information from optic disc images; (b) classification of optic disc images, based on shape information, to distinguish between healthy and glaucomatous optic discs. We apply Multi Layer Perceptrons, Support Vector Machines and Bayesian Networks for feature sub-set selection and image classification; and (c) clustering of optic disc images, based on shape information, using Self-Organizing Maps to visualize sub-types of glaucomatous optic disc damage. Our framework offers an automated and objective analysis of optic nerve images that can potentially support both diagnosis and monitoring of glaucoma.

  17. Information virtual indicator with combination of diffractive optical elements

    Science.gov (United States)

    Grad, Y. A.; Drozdova, E. A.; Nayden, L. A.; Nikolaev, V. V.; Odinokov, S. B.; Solomashenko, A. B.

    2016-08-01

    A combination of diffractive optical elements for monochrome information virtual indicators is described. To reduce the spectral "blurring" of image in monochrome indicators with OLED-display or LCD-display with LED backlight the possibility of using the volume reflection hologram as a spectral filter is investigated. The theoretical and experimental results show that the volume reflection hologram can be used as part of a monochrome virtual indicator containing OLED-, LCOS- or LCD-display with LED-backlight and relief-phase gratings for output of radiation from substrate to reduce the spectral "blurring" of image.

  18. Imaging granulomatous lesions with optical coherence tomography

    DEFF Research Database (Denmark)

    Banzhaf, Christina; Jemec, Gregor B E

    2012-01-01

    To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT) images and compare this to previous studies of nonmelanoma skin tumors.......To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT) images and compare this to previous studies of nonmelanoma skin tumors....

  19. Combined Sparsifying Transforms for Compressive Image Fusion

    Directory of Open Access Journals (Sweden)

    ZHAO, L.

    2013-11-01

    Full Text Available In this paper, we present a new compressive image fusion method based on combined sparsifying transforms. First, the framework of compressive image fusion is introduced briefly. Then, combined sparsifying transforms are presented to enhance the sparsity of images. Finally, a reconstruction algorithm based on the nonlinear conjugate gradient is presented to get the fused image. The simulations demonstrate that by using the combined sparsifying transforms better results can be achieved in terms of both the subjective visual effect and the objective evaluation indexes than using only a single sparsifying transform for compressive image fusion.

  20. Optical Coherence Tomography for Brain Imaging

    Science.gov (United States)

    Liu, Gangjun; Chen, Zhongping

    Recently, there has been growing interest in using OCT for brain imaging. A feasibility study of OCT for guiding deep brain probes has found that OCT can differentiate the white matter and gray matter because the white matter tends to have a higher peak reflectivity and steeper attenuation rate compared to gray matter. In vivo 3D visualization of the layered organization of a rat olfactory bulb with OCT has been demonstrated. OCT has been used for single myelin fiber imaging in living rodents without labeling. The refractive index in the rat somatosensory cortex has also been measured with OCT. In addition, functional extension of OCT, such as Doppler-OCT (D-OCT), polarization sensitive-OCT (PS-OCT), and phase-resolved-OCT (PR-OCT), can image and quantify physiological parameters in addition to the morphological structure image. Based on the scattering changes during neural activity, OCT has been used to measure the functional activation in neuronal tissues. PS-OCT, which combines polarization sensitive detection with OCT to determine tissue birefringence, has been used for the localization of nerve fiber bundles and the mapping of micrometer-scale fiber pathways in the brain. D-OCT, also named optical Doppler tomography (ODT), combines the Doppler principle with OCT to obtain high resolution tomographic images of moving constituents in highly scattering biological tissues. D-OCT has been successfully used to image cortical blood flow and map the blood vessel network for brain research. In this chapter, the principle and technology of OCT and D-OCT are reviewed and examples of potential applications are described.

  1. Optical Image Classification Using Optical/digital Hybrid Image Processing Systems.

    Science.gov (United States)

    Li, Xiaoyang

    1990-01-01

    Offering parallel and real-time operations, optical image classification is becoming a general technique in the solution of real-life image classification problems. This thesis investigates several algorithms for optical realization. Compared to other statistical pattern recognition algorithms, the Kittler-Young transform can provide more discriminative feature spaces for image classification. We shall apply the Kittler-Young transform to image classification and implement it on optical systems. A feature selection criterion is designed for the application of the Kittler -Young transform to image classification. The realizations of the Kittler-Young transform on both a joint transform correlator and a matrix multiplier are successively conducted. Experiments of applying this technique to two-category and three-category problems are demonstrated. To combine the advantages of the statistical pattern recognition algorithms and the neural network models, processes using the two methods are studied. The Karhunen-Loeve Hopfield model is developed for image classification. This model has significant improvement in the system capacity and the capability of using image structures for more discriminative classification processes. As another such hybrid process, we propose the feature extraction perceptron. The application of feature extraction techniques to the perceptron shortens its learning time. An improved activation function of neurons (dynamic activation function), its design and updating rule for fast learning process and high space-bandwidth product image classification are also proposed. We have shortened by two-thirds the learning time on the feature extraction perceptron as compared with the original perceptron. By using this architecture, we have shown that the classification performs better than both the Kittler-Young transform and the original perceptron.

  2. Combining image-processing and image compression schemes

    Science.gov (United States)

    Greenspan, H.; Lee, M.-C.

    1995-01-01

    An investigation into the combining of image-processing schemes, specifically an image enhancement scheme, with existing compression schemes is discussed. Results are presented on the pyramid coding scheme, the subband coding scheme, and progressive transmission. Encouraging results are demonstrated for the combination of image enhancement and pyramid image coding schemes, especially at low bit rates. Adding the enhancement scheme to progressive image transmission allows enhanced visual perception at low resolutions. In addition, further progressing of the transmitted images, such as edge detection schemes, can gain from the added image resolution via the enhancement.

  3. Combined hostile fire and optics detection

    Science.gov (United States)

    Brännlund, Carl; Tidström, Jonas; Henriksson, Markus; Sjöqvist, Lars

    2013-10-01

    Snipers and other optically guided weapon systems are serious threats in military operations. We have studied a SWIR (Short Wave Infrared) camera-based system with capability to detect and locate snipers both before and after shot over a large field-of-view. The high frame rate SWIR-camera allows resolution of the temporal profile of muzzle flashes which is the infrared signature associated with the ejection of the bullet from the rifle. The capability to detect and discriminate sniper muzzle flashes with this system has been verified by FOI in earlier studies. In this work we have extended the system by adding a laser channel for optics detection. A laser diode with slit-shaped beam profile is scanned over the camera field-of-view to detect retro reflection from optical sights. The optics detection system has been tested at various distances up to 1.15 km showing the feasibility to detect rifle scopes in full daylight. The high speed camera gives the possibility to discriminate false alarms by analyzing the temporal data. The intensity variation, caused by atmospheric turbulence, enables discrimination of small sights from larger reflectors due to aperture averaging, although the targets only cover a single pixel. It is shown that optics detection can be integrated in combination with muzzle flash detection by adding a scanning rectangular laser slit. The overall optics detection capability by continuous surveillance of a relatively large field-of-view looks promising. This type of multifunctional system may become an important tool to detect snipers before and after shot.

  4. A Multimodality Hybrid Gamma-Optical Camera for Intraoperative Imaging

    Directory of Open Access Journals (Sweden)

    John E. Lees

    2017-03-01

    Full Text Available The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detector design which can offer stereoscopic images, depth estimation of gamma-emitting sources, and simultaneous gamma and fluorescence imaging. Recent improvements to the hybrid camera have been used to produce dual-modality images in both laboratory simulations and in the clinic. Hybrid imaging of a patient who underwent thyroid scintigraphy is reported. In addition, we present data which shows that the hybrid camera concept can be extended to estimate the position and depth of radionuclide distribution within an object and also report the first combined gamma and Near-Infrared (NIR fluorescence images.

  5. Analytic image concept combined to SENSE reconstruction

    OpenAIRE

    Yankam Njiwa, J; Baltes, C.; Rudin, M.

    2011-01-01

    Two approaches of reconstructing undersampled partial k-space data, acquired with multiple coils are compared: homodyne detection combined with SENSE (HM_SENSE) and analytic image reconstruction combined with SENSE (AI_SENSE). The latter overcomes limitations of HM_ SENSE by considering aliased images as analytic thus avoiding the need for phase correction required for HM_SENSE. MATERIALS AND METHODS: In vivo imaging experiments were carried out in male Lewis rats using both gradient echo...

  6. Optics for Advanced Neutron Imaging and Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Moncton, David E. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Khaykovich, Boris [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2016-03-30

    During the report period, we continued the work as outlined in the original proposal. We have analyzed potential optical designs of Wolter mirrors for the neutron-imaging instrument VENUS, which is under construction at SNS. In parallel, we have conducted the initial polarized imaging experiment at Helmholtz Zentrum, Berlin, one of very few of currently available polarized-imaging facilities worldwide.

  7. NAOMI: nanoparticle-assisted optical molecular imaging

    Science.gov (United States)

    Faber, Dirk J.; de Bruin, Martijn; Aalders, Maurice C. G.; Verbraak, Frank D.; van Leeuwen, Ton G.

    2007-02-01

    We present our first steps towards nanoparticle assisted, optical molecular imaging (NAOMI) using biodegradable nanoparticles. Our focus is on using optical coherence tomography(OCT) as the imaging modality. We propose to use nanoparticles based on biodegradable polymers, loaded with carefully selected dyes as contrast agent, and outline a method for establishing their desired optical properties prior to synthesis. Moreover, we perform a qualitative pilot study using these biodegradable nanoparticles, measuring their optical properties which are found to be in line with theoretical predictions.

  8. Radio-Optical Imaging of ATLBS Survey

    Indian Academy of Sciences (India)

    Kshitij Thorat

    2011-12-01

    We present the radio-optical imaging of ATLBS, a sensitive radio survey (Subrahmanyan et al. 2010). The primary aim of the ATLBS survey is to image low-power radio sources which form the bulk of the radio source population to moderately high red-shifts ( ∼ 1.0). The accompanying multiband optical and near infra-red observations provide information about the hosts and environments of the radio sources. We give here details of the imaging of the radio data and optical data for the ATLBS survey.

  9. Reconfigurable optical power splitter/combiner based on Opto-VLSI processing.

    Science.gov (United States)

    Mustafa, Haithem; Xiao, Feng; Alameh, Kamal

    2011-10-24

    A novel 1×4 reconfigurable optical splitter/combiner structure based on Opto-VLSI processor and 4-f imaging system with high resolution is proposed and experimentally demonstrated. By uploading optimized multicasting phase holograms onto the software-driven Opto-VLSI processor, an input optical signal is dynamically split into different output fiber ports with user-defined splitting ratios. Also, multiple input optical signals are dynamically combined with arbitrary user-defined weights.

  10. Adaptive optics optical coherence tomography for retina imaging

    Institute of Scientific and Technical Information of China (English)

    Guohua Shi; Yun Dai; Ling Wang; Zhihua Ding; Xuejun Rao; Yudong Zhang

    2008-01-01

    When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 frames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented.

  11. Space-based optical image encryption.

    Science.gov (United States)

    Chen, Wen; Chen, Xudong

    2010-12-20

    In this paper, we propose a new method based on a three-dimensional (3D) space-based strategy for the optical image encryption. The two-dimensional (2D) processing of a plaintext in the conventional optical encryption methods is extended to a 3D space-based processing. Each pixel of the plaintext is considered as one particle in the proposed space-based optical image encryption, and the diffraction of all particles forms an object wave in the phase-shifting digital holography. The effectiveness and advantages of the proposed method are demonstrated by numerical results. The proposed method can provide a new optical encryption strategy instead of the conventional 2D processing, and may open up a new research perspective for the optical image encryption.

  12. Magnetic resonance imaging of optic nerve

    Directory of Open Access Journals (Sweden)

    Foram Gala

    2015-01-01

    Full Text Available Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI, plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies.

  13. Digital image compression for a 2f multiplexing optical setup

    Science.gov (United States)

    Vargas, J.; Amaya, D.; Rueda, E.

    2016-07-01

    In this work a virtual 2f multiplexing system was implemented in combination with digital image compression techniques and redundant information elimination. Depending on the image type to be multiplexed, a memory-usage saving of as much as 99% was obtained. The feasibility of the system was tested using three types of images, binary characters, QR codes, and grey level images. A multiplexing step was implemented digitally, while a demultiplexing step was implemented in a virtual 2f optical setup following real experimental parameters. To avoid cross-talk noise, each image was codified with a specially designed phase diffraction carrier that would allow the separation and relocation of the multiplexed images on the observation plane by simple light propagation. A description of the system is presented together with simulations that corroborate the method. The present work may allow future experimental implementations that will make use of all the parallel processing capabilities of optical systems.

  14. Development of catheters for combined intravascular ultrasound and photoacoustic imaging

    Science.gov (United States)

    Karpiouk, Andrei B.; Wang, Bo; Emelianov, Stanislav Y.

    2009-02-01

    Coronary atherosclerosis is a complex disease accompanied by the development of plaques in the arterial wall. Since the vulnerability of the plaques depends on their composition, the appropriate treatment of the arteriosclerosis requires a reliable characterization of the plaques' geometry and content. The intravascular ultrasound (IVUS) imaging is capable of providing structural details of the plaques as well as some functional information. In turn, more functional information about the same plaques can be obtained from intravascular photoacoustic (IVPA) images since the optical properties of the plaque's components differ from that of their environment. The combined IVUS/IVPA imaging is capable of simultaneously detecting and differentiating the plaques, thus determining their vulnerability. The potential of combined IVUS/IVPA imaging has already been demonstrated in phantoms and ex-vivo experiments. However, for in-vivo or clinical imaging, an integrated IVUS/IVPA catheter is required. In this paper, we introduce two prototypes of integrated IVUS/IVPA catheters for in-vivo imaging based on a commercially available single-element IVUS imaging catheter. The light delivery systems are developed using multimode optical fibers with custom-designed distal tips. Both prototypes were tested and compared using an arterial mimicking phantom. The advantages and limitations of both designs are discussed. Overall, the results of our studies suggest that both designs of integrated IVUS/IVPA catheter have a potential for in-vivo IVPA/IVUS imaging of atherosclerotic plaques.

  15. Adaptive optics imaging of the retina.

    Science.gov (United States)

    Battu, Rajani; Dabir, Supriya; Khanna, Anjani; Kumar, Anupama Kiran; Roy, Abhijit Sinha

    2014-01-01

    Adaptive optics is a relatively new tool that is available to ophthalmologists for study of cellular level details. In addition to the axial resolution provided by the spectral-domain optical coherence tomography, adaptive optics provides an excellent lateral resolution, enabling visualization of the photoreceptors, blood vessels and details of the optic nerve head. We attempt a mini review of the current role of adaptive optics in retinal imaging. PubMed search was performed with key words Adaptive optics OR Retina OR Retinal imaging. Conference abstracts were searched from the Association for Research in Vision and Ophthalmology (ARVO) and American Academy of Ophthalmology (AAO) meetings. In total, 261 relevant publications and 389 conference abstracts were identified.

  16. Adaptive optics imaging of the retina

    Directory of Open Access Journals (Sweden)

    Rajani Battu

    2014-01-01

    Full Text Available Adaptive optics is a relatively new tool that is available to ophthalmologists for study of cellular level details. In addition to the axial resolution provided by the spectral-domain optical coherence tomography, adaptive optics provides an excellent lateral resolution, enabling visualization of the photoreceptors, blood vessels and details of the optic nerve head. We attempt a mini review of the current role of adaptive optics in retinal imaging. PubMed search was performed with key words Adaptive optics OR Retina OR Retinal imaging. Conference abstracts were searched from the Association for Research in Vision and Ophthalmology (ARVO and American Academy of Ophthalmology (AAO meetings. In total, 261 relevant publications and 389 conference abstracts were identified.

  17. Optical image encryption using multilevel Arnold transform and noninterferometric imaging

    Science.gov (United States)

    Chen, Wen; Chen, Xudong

    2011-11-01

    Information security has attracted much current attention due to the rapid development of modern technologies, such as computer and internet. We propose a novel method for optical image encryption using multilevel Arnold transform and rotatable-phase-mask noninterferometric imaging. An optical image encryption scheme is developed in the gyrator transform domain, and one phase-only mask (i.e., phase grating) is rotated and updated during image encryption. For the decryption, an iterative retrieval algorithm is proposed to extract high-quality plaintexts. Conventional encoding methods (such as digital holography) have been proven vulnerably to the attacks, and the proposed optical encoding scheme can effectively eliminate security deficiency and significantly enhance cryptosystem security. The proposed strategy based on the rotatable phase-only mask can provide a new alternative for data/image encryption in the noninterferometric imaging.

  18. All-optical scanhead for ultrasound and photoacoustic imaging-Imaging mode switching by dichroic filtering.

    Science.gov (United States)

    Hsieh, Bao-Yu; Chen, Sung-Liang; Ling, Tao; Guo, L Jay; Li, Pai-Chi

    2014-03-01

    Ultrasound (US) and photoacoustic (PA) multimodality imaging has the advantage of combining good acoustic resolution with high optical contrast. The use of an all-optical scanhead for both imaging modalities can simplify integration of the two systems and miniaturize the imaging scanhead. Herein we propose and demonstrate an all-optical US/PA scanhead using a thin plate for optoacoustic generation in US imaging, a polymer microring resonator for acoustic detection, and a dichroic filter to switch between the two imaging modes by changing the laser wavelength. A synthetic-aperture focusing technique is used to improve the resolution and contrast. Phantom images demonstrate the feasibility of this design, and show that axial and lateral resolutions of 125 μm and 2.52°, respectively, are possible.

  19. Optical and digital microscopic imaging techniques and applications in pathology

    OpenAIRE

    Xiaodong Chen; Bin Zheng; Hong Liu

    2011-01-01

    The conventional optical microscope has been the primary tool in assisting pathological examinations. The modern digital pathology combines the power of microscopy, electronic detection, and computerized analysis. It enables cellular-, molecular-, and genetic-imaging at high efficiency and accuracy to facilitate clinical screening and diagnosis. This paper first reviews the fundamental concepts of microscopic imaging and introduces the technical features and associated clinical applications o...

  20. Asymmetric Beam Combination for Optical Interferometry

    CERN Document Server

    Monnier, J D

    2001-01-01

    Optical interferometers increasingly use single-mode fibers as spatial filters to convert varying wavefront distortion into intensity fluctuations which can be monitored for accurate calibration of fringe amplitudes. Here I propose using an asymmetric coupler to allow the photometric intensities of each telescope beam to be measured at the same time as the fringe visibility, but without the need for dedicated photometric outputs, which reduce the light throughput in the interferometric channels. In the read-noise limited case often encountered in the infrared, I show that a 53% improvement in signal-to-noise ratio for the visibility amplitude measurement is achievable, when compared to a balanced coupler setup with 50% photometric taps (e.g., the FLUOR experiment). In the Poisson-noise limit appropriate for visible light, the improvement is reduced to only ~8%. This scheme also reduces the cost and complexity of the beam combination since fewer components and detectors are required, and can be extended to mor...

  1. Optical Digital Image Storage System

    Science.gov (United States)

    1991-03-18

    This could be accomplished even if the files were artificially determined. " Super files," composed of a number of files, could be artificially created...in order to expedite transfer through the scanning process. These " super files" could later be broken down into their actual component files. Another...hesitant about implementing an optical disk system. While Sandra Napier believed it "looks promising," she felt an optical disk replacement of microfilm

  2. Optical encryption with selective computational ghost imaging

    Science.gov (United States)

    Zafari, Mohammad; kheradmand, Reza; Ahmadi-Kandjani, Sohrab

    2014-10-01

    Selective computational ghost imaging (SCGI) is a technique which enables the reconstruction of an N-pixel image from N measurements or less. In this paper we propose an optical encryption method based on SCGI and experimentally demonstrate that this method has much higher security under eavesdropping and unauthorized accesses compared with previous reported methods.

  3. Optical imaging of fast, dynamic neurophysiological function.

    Energy Technology Data Exchange (ETDEWEB)

    Rector, D. M. (David M.); Carter, K. M. (Kathleen M.); Yao, X. (Xincheng); George, J. S. (John S.)

    2002-01-01

    Fast evoked responses were imaged from rat dorsal medulla and whisker barrel cortex. To investigate the biophysical mechanisms involved, fast optical responses associated with isolated crustacean nerve stimulation were recorded using birefringence and scattered light. Such studies allow optimization of non-invasive imaging techniques being developed for use in humans.

  4. Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy1

    Science.gov (United States)

    Fujimoto, James G; Pitris, Costas; Boppart, Stephen A; Brezinski, Mark E

    2000-01-01

    Abstract Optical coherence tomography (OCT) is an emerging technology for performing high-resolution cross-sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cross-sectional images of tissue structure on the micron scale in situ and in real time. Using OCT in combination with catheters and endoscopes enables high-resolution intraluminal imaging of organ systems. OCT can function as a type of optical biopsy and is a powerful imaging technology for medical diagnostics because unlike conventional histopathology which requires removal of a tissue specimen and processing for microscopic examination, OCT can provide images of tissue in situ and in real time. OCT can be used where standard excisional biopsy is hazardous or impossible, to reduce sampling errors associated with excisional biopsy, and to guide interventional procedures. In this paper, we review OCT technology and describe its potential biomedical and clinical applications. PMID:10933065

  5. Optical image encryption using Kronecker product and hybrid phase masks

    Science.gov (United States)

    Kumar, Ravi; Bhaduri, Basanta

    2017-10-01

    In this paper, we propose a new technique for security enhancement in optical image encryption system. In this technique we have used the Kronecker product of two random matrices along with the double random phase encoding (DRPE) scheme in the Fresnel domain for optical image encryption. The phase masks used here are different than the random masks used in conventional DRPE scheme. These hybrid phase masks are generated by using the combination of random phase masks and a secondary image. For encryption, the input image is first randomized and then the DRPE in the Fresnel domain is performed using the hybrid phase masks. Secondly, the Kronecker product of two random matrices is multiplied with the DRPE output to get the final encoded image for transmission. The proposed technique consists of more unknown keys for enhanced security and robust against various attacks. The simulation results along with effects under various attacks are presented in support of the proposed technique.

  6. Optical and Digital Microscopic Imaging Techniques and Applications in Pathology

    Directory of Open Access Journals (Sweden)

    Xiaodong Chen

    2011-01-01

    Full Text Available The conventional optical microscope has been the primary tool in assisting pathological examinations. The modern digital pathology combines the power of microscopy, electronic detection, and computerized analysis. It enables cellular-, molecular-, and genetic-imaging at high efficiency and accuracy to facilitate clinical screening and diagnosis. This paper first reviews the fundamental concepts of microscopic imaging and introduces the technical features and associated clinical applications of optical microscopes, electron microscopes, scanning tunnel microscopes, and fluorescence microscopes. The interface of microscopy with digital image acquisition methods is discussed. The recent developments and future perspectives of contemporary microscopic imaging techniques such as three-dimensional and in vivo imaging are analyzed for their clinical potentials.

  7. Computer-aided interpretation approach for optical tomographic images

    Science.gov (United States)

    Klose, Christian D.; Klose, Alexander D.; Netz, Uwe J.; Scheel, Alexander K.; Beuthan, Jürgen; Hielscher, Andreas H.

    2010-11-01

    A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) in human finger joints using optical tomographic images. The image interpretation method employs a classification algorithm that makes use of a so-called self-organizing mapping scheme to classify fingers as either affected or unaffected by RA. Unlike in previous studies, this allows for combining multiple image features, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging, and inspection of optical tomographic images), were used to produce ground truth benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities, while others to higher specificities when compared to single parameter classifications employed in previous studies. Maximum performances are reached when combining the minimum/maximum ratio of the absorption coefficient and image variance. In this case, sensitivities and specificities over 0.9 can be achieved. These values are much higher than values obtained when only single parameter classifications were used, where sensitivities and specificities remained well below 0.8.

  8. Image correction in magneto-optical microscopy

    DEFF Research Database (Denmark)

    Paturi, P.; Larsen, B.H.; Jacobsen, B.A.

    2003-01-01

    An image-processing procedure that assures correct determination of the magnetic field distribution of magneto-optical images is presented. The method remedies image faults resulting from sources that are proportional to the incident light intensity, such as different types of defects in the indi......An image-processing procedure that assures correct determination of the magnetic field distribution of magneto-optical images is presented. The method remedies image faults resulting from sources that are proportional to the incident light intensity, such as different types of defects...... in the indicator film and unevenness of light, as well as additive signals from detector bias, external light sources, etc. When properly corrected a better measurement of the local magnetic field can be made, even in the case of heavily damaged films. For superconductors the magnetic field distributions may...

  9. NAOMI: nanoparticle assisted optical molecular imaging

    Science.gov (United States)

    Faber, Dirk J.; van Velthoven, Mirjam E. J.; de Bruin, Martijn; Aalders, Maurice C. G.; Verbraak, Frank D.; Graf, Christina; van Leeuwen, Ton G.

    2006-02-01

    Our first steps towards nanoparticle assisted, optical molecular imaging (NAOMI) using OCT as the imaging modality are presented. We derive an expression to estimate the sensitivity of this technique. We propose to use nanoparticles based on biodegradable polymers, loaded with suitable dyes as contrast agent, and outline a method for establishing their desired optical properties prior to synthesis. This report presents preliminary results of our investigation on the use of nanoshells to serve as contrast agents We injected nanoshells with specific contrast features in the 800 nm wavelength region in excised porcine eyes. The nanoshells showed up as bright reflecting structures in the OCT images, which confirm their potential as contrast agents.

  10. Gated frequency-resolved optical imaging with an optical parametric amplifier for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, S.M.; Bliss, D.E.

    1997-02-01

    Implementation of optical imagery in a diffuse inhomogeneous medium such as biological tissue requires an understanding of photon migration and multiple scattering processes which act to randomize pathlength and degrade image quality. The nature of transmitted light from soft tissue ranges from the quasi-coherent properties of the minimally scattered component to the random incoherent light of the diffuse component. Recent experimental approaches have emphasized dynamic path-sensitive imaging measurements with either ultrashort laser pulses (ballistic photons) or amplitude modulated laser light launched into tissue (photon density waves) to increase image resolution and transmissive penetration depth. Ballistic imaging seeks to compensate for these {open_quotes}fog-like{close_quotes} effects by temporally isolating the weak early-arriving image-bearing component from the diffusely scattered background using a subpicosecond optical gate superimposed on the transmitted photon time-of-flight distribution. The authors have developed a broadly wavelength tunable (470 nm -2.4 {mu}m), ultrashort amplifying optical gate for transillumination spectral imaging based on optical parametric amplification in a nonlinear crystal. The time-gated image amplification process exhibits low noise and high sensitivity, with gains greater than 104 achievable for low light levels. We report preliminary benchmark experiments in which this system was used to reconstruct, spectrally upcovert, and enhance near-infrared two-dimensional images with feature sizes of 65 {mu}m/mm{sup 2} in background optical attenuations exceeding 10{sup 12}. Phase images of test objects exhibiting both absorptive contrast and diffuse scatter were acquired using a self-referencing Shack-Hartmann wavefront sensor in combination with short-pulse quasi-ballistic gating. The sensor employed a lenslet array based on binary optics technology and was sensitive to optical path distortions approaching {lambda}/100.

  11. Optical imaging for breast cancer prescreening

    Directory of Open Access Journals (Sweden)

    Godavarty A

    2015-07-01

    Full Text Available Anuradha Godavarty,1 Suset Rodriguez,1 Young-Jin Jung,2 Stephanie Gonzalez1 1Optical Imaging Laboratory, Department of Biomedical Engineering, Florida International University, Miami, FL, USA; 2Department of Radiological Science, Dongseo University, Busan, South Korea Abstract: Breast cancer prescreening is carried out prior to the gold standard screening using X-ray mammography and/or ultrasound. Prescreening is typically carried out using clinical breast examination (CBE or self-breast examinations (SBEs. Since CBE and SBE have high false-positive rates, there is a need for a low-cost, noninvasive, non-radiative, and portable imaging modality that can be used as a prescreening tool to complement CBE/SBE. This review focuses on the various hand-held optical imaging devices that have been developed and applied toward early-stage breast cancer detection or as a prescreening tool via phantom, in vivo, and breast cancer imaging studies. Apart from the various optical devices developed by different research groups, a wide-field fiber-free near-infrared optical scanner has been developed for transillumination-based breast imaging in our Optical Imaging Laboratory. Preliminary in vivo studies on normal breast tissues, with absorption-contrasted targets placed in the intramammary fold, detected targets as deep as 8.8 cm. Future work involves in vivo imaging studies on breast cancer subjects and comparison with the gold standard X-ray mammography approach. Keywords: diffuse optical imaging, near-infrared, hand-held devices, breast cancer, prescreening, early detection 

  12. Spectroelectrochemistry: The Combination of Optical and Electrochemical Techniques.

    Science.gov (United States)

    Heineman, William R.

    1983-01-01

    Two different techniques, electrochemistry and spectroscopy, can be combined for studying the redox chemistry of inorganic, organic, and biological molecules. Several commonly used spectroelectrochemical methods and their applications are described. Includes discussions of optically transparent electrodes, optical absorption/fluorescence…

  13. In vivo optical imaging of cortical spreading depression in rat

    Science.gov (United States)

    Chen, Shangbin; Li, Pengcheng; Luo, Weihua; Gong, Hui; Cheng, Haiying; Luo, Qingming

    2003-12-01

    Intrinsic optical signals imaging (IOSI) and laser speckle imaging (LSI) are both novel techniques for functional neuroimaging in vivo. Combining them to study cortical spreading depression (CSD) which is an important disease model for migraine and other neurological disorders. CSD were induced by pinprick in Sprague-Dawley rats. Intrinsic optical signals (IOS) at 540 nm showed CSD evolution happened in one hemisphere cortex at speeds of 3.7+/-0.4 mm/min, and the vasodilation closely correlated a four-phasic response. By LSI, we observed a transient and significant increase cerebral blood flow (CBF). In this paper, optical imaging would be showed as a powerful tool for describing the hemodynamic character during CSD in rat.

  14. Optical fibers and RF a natural combination

    CERN Document Server

    Romeiser, Malcolm

    2004-01-01

    The optical fiber industry has experienced a period of consolidation and reorganization and is now poised for a new surge in growth. To take advantage of that growth, and to respond to the demand to use fiber more efficiently, designers need a better understanding of fiber optics. Taking the approach that optical fibers are an extension of RF-based communications, the author explains basic optical concepts, applications, and systems; the nature and performance characteristics of optical fibers; and optical sources, connectors and splices. Subsequent chapters explore current applications of fib

  15. Analysis of optical amplifier noise in coherent optical communication systems with optical image rejection receivers

    DEFF Research Database (Denmark)

    Jørgensen, Bo Foged; Mikkelsen, Benny; Mahon, Cathal J.

    1992-01-01

    performance. Two types of optical image rejection receivers are investigated: a novel, all-optical configuration and the conventional, microwave-based configuration. The analysis shows that local oscillator-spontaneous emission beat noise (LO-SP), signal-spontaneous emission beat noise (S-SP), and spontaneous......A detailed theoretical analysis of optical amplifier noise in coherent optical communication systems with heterodyne receivers is presented. The analysis quantifies in particular how optical image rejection receiver configurations reduce the influence of optical amplifier noise on system......-spontaneous beat noise (SP-SP) can all be reduced by 3 dB, thereby doubling the dynamic range of the optical amplifier. A 2.5-dB improvement in dynamic range has been demonstrated experimentally with the all-optical image rejection configuration. The implications of the increased dynamic range thus obtained...

  16. Optical encryption for large-sized images

    Science.gov (United States)

    Sanpei, Takuho; Shimobaba, Tomoyoshi; Kakue, Takashi; Endo, Yutaka; Hirayama, Ryuji; Hiyama, Daisuke; Hasegawa, Satoki; Nagahama, Yuki; Sano, Marie; Oikawa, Minoru; Sugie, Takashige; Ito, Tomoyoshi

    2016-02-01

    We propose an optical encryption framework that can encrypt and decrypt large-sized images beyond the size of the encrypted image using our two methods: random phase-free method and scaled diffraction. In order to record the entire image information on the encrypted image, the large-sized images require the random phase to widely diffuse the object light over the encrypted image; however, the random phase gives rise to the speckle noise on the decrypted images, and it may be difficult to recognize the decrypted images. In order to reduce the speckle noise, we apply our random phase-free method to the framework. In addition, we employ scaled diffraction that calculates light propagation between planes with different sizes by changing the sampling rates.

  17. Multimodal optical imaging for detecting breast cancer

    Science.gov (United States)

    Patel, Rakesh; Khan, Ashraf; Wirth, Dennis; Kamionek, Michal; Kandil, Dina; Quinlan, Robert; Yaroslavsky, Anna N.

    2012-06-01

    The goal of the study was to evaluate wide-field and high-resolution multimodal optical imaging, including polarization, reflectance, and fluorescence for the intraoperative detection of breast cancer. Lumpectomy specimens were stained with 0.05 mg/ml aqueous solution of methylene blue (MB) and imaged. Wide-field reflectance images were acquired between 390 and 750 nm. Wide-field fluorescence images were excited at 640 nm and registered between 660 and 750 nm. High resolution confocal reflectance and fluorescence images were excited at 642 nm. Confocal fluorescence images were acquired between 670 nm and 710 nm. After imaging, the specimens were processed for hematoxylin and eosin (H&E) histopathology. Histological slides were compared with wide-field and high-resolution optical images to evaluate correlation of tumor boundaries and cellular morphology, respectively. Fluorescence polarization imaging identified the location, size, and shape of the tumor in all the cases investigated. Averaged fluorescence polarization values of tumor were higher as compared to normal tissue. Statistical analysis confirmed the significance of these differences. Fluorescence confocal imaging enabled cellular-level resolution. Evaluation and statistical analysis of MB fluorescence polarization values registered from single tumor and normal cells demonstrated higher fluorescence polarization from cancer. Wide-field high-resolution fluorescence and fluorescence polarization imaging shows promise for intraoperative delineation of breast cancers.

  18. Integration of optical imaging with a small animal irradiator

    Energy Technology Data Exchange (ETDEWEB)

    Weersink, Robert A., E-mail: robert.weersink@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada and Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1P5 (Canada); Ansell, Steve; Wang, An; Wilson, Graham [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Shah, Duoaud [Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1P5 (Canada); Lindsay, Patricia E. [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 1A1 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1P5 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 1A1 (Canada); Ontario Cancer Institute, Princess Margaret Hospital, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5S 1A1 (Canada)

    2014-10-15

    -dimensional targeting of a light source in the mouse phantom based on optical imaging along the anterior/posterior direction was accurate to 0.55 mm. The mean square residual error in the normalized measured projected surface intensities versus the calculated normalized intensities ranged between 0.0016 and 0.006. Optimizing the position reduced this error from 0.00016 to 0.0004 with distances ranging between 0.7 and 1 mm between the actual and calculated position source positions. Conclusions: The integration of optical imaging on an existing small animal irradiation platform has been accomplished. A targeting accuracy of 1 mm can be achieved in rigid, homogeneous phantoms. The combination of optical imaging with a CBCT image-guided small animal irradiator offers the potential to deliver functionally targeted dose distributions, as well as monitor spatial and temporal functional changes that occur with radiation therapy.

  19. Intensity interferometry: Optical imaging with kilometer baselines

    CERN Document Server

    Dravins, Dainis

    2016-01-01

    Optical imaging with microarcsecond resolution will reveal details across and outside stellar surfaces but requires kilometer-scale interferometers, challenging to realize either on the ground or in space. Intensity interferometry, electronically connecting independent telescopes, has a noise budget that relates to the electronic time resolution, circumventing issues of atmospheric turbulence. Extents up to a few km are becoming realistic with arrays of optical air Cherenkov telescopes (primarily erected for gamma-ray studies), enabling an optical equivalent of radio interferometer arrays. Pioneered by Hanbury Brown and Twiss, digital versions of the technique have now been demonstrated, reconstructing diffraction-limited images from laboratory measurements over hundreds of optical baselines. This review outlines the method from its beginnings, describes current experiments, and sketches prospects for future observations.

  20. Optical secure image verification system based on ghost imaging

    Science.gov (United States)

    Wu, Jingjing; Haobogedewude, Buyinggaridi; Liu, Zhengjun; Liu, Shutian

    2017-09-01

    The ghost imaging can perform Fourier-space filtering by tailoring the configuration. We proposed a novel optical secure image verification system based on this theory with the help of phase matched filtering. In the verification process, the system key and the ID card which contain the information of the correct image and the information to be verified are put in the reference and the test paths, respectively. We demonstrate that the ghost imaging configuration can perform an incoherent correlation between the system key and the ID card. The correct verification manifests itself with a correlation peak in the ghost image. The primary image and the image to be verified are encrypted and encoded into pure phase masks beforehand for security. Multi-image secure verifications can also be implemented in the proposed system.

  1. An All-Fiber-Optic Combined System of Noncontact Photoacoustic Tomography and Optical Coherence Tomography.

    Science.gov (United States)

    Eom, Jonghyun; Shin, Jun Geun; Park, Soongho; Rim, Sunghwan; Lee, Byeong Ha

    2016-05-20

    We propose an all-fiber-based dual-modal imaging system that combines noncontact photoacoustic tomography (PAT) and optical coherence tomography (OCT). The PAT remotely measures photoacoustic (PA) signals with a 1550-nm laser on the surface of a sample by utilizing a fiber interferometer as an ultrasound detector. The fiber-based OCT, employing a swept-source laser centered at 1310 nm, shares the sample arm of the PAT system. The fiber-optic probe for the combined system was homemade with a lensed single-mode fiber (SMF) and a large-core multimode fiber (MMF). The compact and robust common probe is capable of obtaining both the PA and the OCT signals at the same position without any physical contact. Additionally, the MMF of the probe delivers the short pulses of a Nd:YAG laser to efficiently excite the PA signals. We experimentally demonstrate the feasibility of the proposed dual-modal system with a phantom made of a fishing line and a black polyethylene terephthalate fiber in a tissue mimicking solution. The all-fiber-optic system, capable of providing complementary information about absorption and scattering, has a promising potential in minimally invasive and endoscopic imaging.

  2. LDA optical setup using holographic imaging configuration

    Science.gov (United States)

    Ghosh, Abhijit; Nirala, A. K.

    2015-11-01

    This paper describes one of the possible ways for improving fringe quality at LDA measuring volume using a holographic imaging configuration consisting of a single hololens. For its comparative study with a conventional imaging configuration, a complete characterization of fringes formed at the measurement volume by both the configuration is presented. Results indicate the qualitative as well as quantitative improvement of the fringes formed at measurement volume by the holographic imaging configuration. Hence it is concluded that use of holographic imaging configuration for making LDA optical setup is a better choice than the conventional one.

  3. Amplitude image processing by diffractive optics.

    Science.gov (United States)

    Cagigal, Manuel P; Valle, Pedro J; Canales, V F

    2016-02-22

    In contrast to the standard digital image processing, which operates over the detected image intensity, we propose to perform amplitude image processing. Amplitude processing, like low pass or high pass filtering, is carried out using diffractive optics elements (DOE) since it allows to operate over the field complex amplitude before it has been detected. We show the procedure for designing the DOE that corresponds to each operation. Furthermore, we accomplish an analysis of amplitude image processing performances. In particular, a DOE Laplacian filter is applied to simulated astronomical images for detecting two stars one Airy ring apart. We also check by numerical simulations that the use of a Laplacian amplitude filter produces less noisy images than the standard digital image processing.

  4. MR imaging of optic chiasmatic glioma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Sook; Lee, Ho Kyu; Kim, Hyun Jin; Ryu, Meung Sun; Goo, Hyun Woo; Yoon, Chong Hyun; Choi, Choong Gon; Suh, Dae Chul; Ra, Young Shin; Khang, Shin Kwang [University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2002-08-01

    To evaluate the MR findings of optic chiasmatic glioma (OCG). MR images were reviewed in 14 patients with histologically proven OCGs and one with neurofibromatosis type 1 (male: female=8:7, mean age=8.5 years.) Tumors were evaluated retrospectively with respect to their size, involvement of the optic pathway, transverse/vertical diameter ratio based on the coronal plane, signal intensities, enhancement pattern, and the presence of a cyst or calcification. Tumors was measured 1.7-5.5 (mean, 3.3) cm in maximum diameter. In ten patients, the optic tracts were involved, and in three, the optic nerves. In 12 patients, tumors had a transverse/vertical diameter ratio of over one, and showed iso (n=5) or low signal intensity (n=10) compared with gray matter at T1-weighted imaging and high signal intensity (n=15) at T2-weighted imaging. Cyst formations were ween in eight patients, and tumors were enhanced strongly and homogeneously in nine and peripherally in four. In seven three was associated hydrocephalus, and in one, calcification. OCG is a suprasellar tumor which can extend into the optic pathway, has a transverse/vertical diameter ratio of more than one, and shows strong and homogeneous enhancement. These MR imaging findings are useful for the differentiation of OCG from other suprasellar tumors.

  5. Laboratory testing & measurement on optical imaging systems

    CSIR Research Space (South Africa)

    Theron, B

    2013-04-01

    Full Text Available  “Rectification” of Greek literature Reproduction of a page of Ibn Sahl's manuscript showing his discovery of the law of refraction”, now known as Snell's law. [5] Some History of Arabic Optics 2 See [4]  Arabic military interest in optics (Caliphs... science. Vol 2. Mathematics and the physical sciences, Routledge, 1996 [5] image used: “Reproduction of a page of Ibn Sahl's manuscript showing his discovery of the law of refraction”, now known as Snell's law.”, image from http...

  6. 3D integral imaging with optical processing

    Science.gov (United States)

    Martínez-Corral, Manuel; Martínez-Cuenca, Raúl; Saavedra, Genaro; Javidi, Bahram

    2008-04-01

    Integral imaging (InI) systems are imaging devices that provide auto-stereoscopic images of 3D intensity objects. Since the birth of this new technology, InI systems have faced satisfactorily many of their initial drawbacks. Basically, two kind of procedures have been used: digital and optical procedures. The "3D Imaging and Display Group" at the University of Valencia, with the essential collaboration of Prof. Javidi, has centered its efforts in the 3D InI with optical processing. Among other achievements, our Group has proposed the annular amplitude modulation for enlargement of the depth of field, dynamic focusing for reduction of the facet-braiding effect, or the TRES and MATRES devices to enlarge the viewing angle.

  7. Synergizing superresolution optical fluctuation imaging with single molecule localization microscopy

    CERN Document Server

    Schidorsky, Shachar; Razvag, Yair; Golan, Yonatan; Weiss, Shimon; Sherman, Eilon

    2016-01-01

    Single molecule localization microscopy (SMLM) techniques enable imaging biological samples well beyond the diffraction limit of light, but they vary significantly in their spatial and temporal resolutions. High-order statistical analysis of temporal fluctuations as in superresolution optical fluctuation imaging (SOFI) also enable imaging beyond diffraction limit, but usually at a lower resolution as compared to SMLM. Since the same data format is acquired for both methods, their algorithms can be applied to the same data set, and thus may be combined synergistically to improve overall imaging performance. Here, we find that SOFI converges much faster than SMLM, provides additive information to SMLM, and can efficiently reject background. We then show how SOFI-assisted SMLM imaging can improve SMLM image reconstruction by rejecting common sources of background, especially under low signal-to-background conditions. The performance of our approach was evaluated using a realistic simulation of fluorescence imagi...

  8. Diffuse Optical Tomography for Brain Imaging: Theory

    Science.gov (United States)

    Yuan, Zhen; Jiang, Huabei

    Diffuse optical tomography (DOT) is a noninvasive, nonionizing, and inexpensive imaging technique that uses near-infrared light to probe tissue optical properties. Regional variations in oxy- and deoxy-hemoglobin concentrations as well as blood flow and oxygen consumption can be imaged by monitoring spatiotemporal variations in the absorption spectra. For brain imaging, this provides DOT unique abilities to directly measure the hemodynamic, metabolic, and neuronal responses to cells (neurons), and tissue and organ activations with high temporal resolution and good tissue penetration. DOT can be used as a stand-alone modality or can be integrated with other imaging modalities such as fMRI/MRI, PET/CT, and EEG/MEG in studying neurophysiology and pathology. This book chapter serves as an introduction to the basic theory and principles of DOT for neuroimaging. It covers the major aspects of advances in neural optical imaging including mathematics, physics, chemistry, reconstruction algorithm, instrumentation, image-guided spectroscopy, neurovascular and neurometabolic coupling, and clinical applications.

  9. Multiplane 3D superresolution optical fluctuation imaging

    CERN Document Server

    Geissbuehler, Stefan; Godinat, Aurélien; Bocchio, Noelia L; Dubikovskaya, Elena A; Lasser, Theo; Leutenegger, Marcel

    2013-01-01

    By switching fluorophores on and off in either a deterministic or a stochastic manner, superresolution microscopy has enabled the imaging of biological structures at resolutions well beyond the diffraction limit. Superresolution optical fluctuation imaging (SOFI) provides an elegant way of overcoming the diffraction limit in all three spatial dimensions by computing higher-order cumulants of image sequences of blinking fluorophores acquired with a conventional widefield microscope. So far, three-dimensional (3D) SOFI has only been demonstrated by sequential imaging of multiple depth positions. Here we introduce a versatile imaging scheme which allows for the simultaneous acquisition of multiple focal planes. Using 3D cross-cumulants, we show that the depth sampling can be increased. Consequently, the simultaneous acquisition of multiple focal planes reduces the acquisition time and hence the photo-bleaching of fluorescent markers. We demonstrate multiplane 3D SOFI by imaging the mitochondria network in fixed ...

  10. On the importance of image formation optics in the design of infrared spectroscopic imaging systems.

    Science.gov (United States)

    Mayerich, David; van Dijk, Thomas; Walsh, Michael J; Schulmerich, Matthew V; Carney, P Scott; Bhargava, Rohit

    2014-08-21

    Infrared spectroscopic imaging provides micron-scale spatial resolution with molecular contrast. While recent work demonstrates that sample morphology affects the recorded spectrum, considerably less attention has been focused on the effects of the optics, including the condenser and objective. This analysis is extremely important, since it will be possible to understand effects on recorded data and provides insight for reducing optical effects through rigorous microscope design. Here, we present a theoretical description and experimental results that demonstrate the effects of commonly-employed cassegranian optics on recorded spectra. We first combine an explicit model of image formation and a method for quantifying and visualizing the deviations in recorded spectra as a function of microscope optics. We then verify these simulations with measurements obtained from spatially heterogeneous samples. The deviation of the computed spectrum from the ideal case is quantified via a map which we call a deviation map. The deviation map is obtained as a function of optical elements by systematic simulations. Examination of deviation maps demonstrates that the optimal optical configuration for minimal deviation is contrary to prevailing practice in which throughput is maximized for an instrument without a sample. This report should be helpful for understanding recorded spectra as a function of the optics, the analytical limits of recorded data determined by the optical design, and potential routes for optimization of imaging systems.

  11. Multicolor 3D super-resolution imaging by quantum dot stochastic optical reconstruction microscopy.

    Science.gov (United States)

    Xu, Jianquan; Tehrani, Kayvan F; Kner, Peter

    2015-03-24

    We demonstrate multicolor three-dimensional super-resolution imaging with quantum dots (QSTORM). By combining quantum dot asynchronous spectral blueing with stochastic optical reconstruction microscopy and adaptive optics, we achieve three-dimensional imaging with 24 nm lateral and 37 nm axial resolution. By pairing two short-pass filters with two appropriate quantum dots, we are able to image single blueing quantum dots on two channels simultaneously, enabling multicolor imaging with high photon counts.

  12. Combined PET/MR imaging in neurology

    DEFF Research Database (Denmark)

    Andersen, Flemming Littrup; Ladefoged, Claes Nøhr; Beyer, Thomas

    2014-01-01

    AIM: Combined PET/MR systems have now become available for clinical use. Given the lack of integrated standard transmission (TX) sources in these systems, attenuation and scatter correction (AC) must be performed using the available MR-images. Since bone tissue cannot easily be accounted for duri...

  13. Multiband optics for imaging systems (Conference Presentation)

    Science.gov (United States)

    Sanghera, Jasbinder S.; Gibson, Daniel J.; Bayya, Shyam S.; Nguyen, Vinh Q.; Kotov, Mikhail; McClain, Collin

    2016-10-01

    There is a strong desire to reduce size and weight of single and multiband IR imaging systems in Intelligence, Surveillance and Reconnaissance (ISR) operations on hand-held, helmet mounted or airborne platforms. NRL is developing new IR glasses that expand the glass map and provide compact solutions to multispectral imaging systems. These glasses were specifically designed to have comparable glass molding temperatures and thermal properties to enable lamination and co-molding of the optics which leads to a reduction in the number of air-glass interfaces (lower Fresnel reflection losses). Our multispectral optics designs using these new materials demonstrate reduced size, complexity and improved performance. This presentation will cover discussions on the new optical materials, multispectral designs, as well fabrication and characterization of new optics. Additionally, graded index (GRIN) optics offer further potential for both weight savings and increased performance but have so far been limited to visible and NIR bands (wavelengths shorter than about 0.9 µm). NRL is developing a capability to extend GRIN optics to longer wavelengths in the infrared by exploiting diffused IR transmitting chalcogenide glasses. These IR-GRIN lenses are compatible with all IR wavebands (SWIR, MWIR and LWIR) and can be used alongside conventional materials. The IR-GRIN lens technology, design space and anti-reflection considerations will be presented in this talk.

  14. Deformable image registration between pathological images and MR image via an optical macro image.

    Science.gov (United States)

    Ohnishi, Takashi; Nakamura, Yuka; Tanaka, Toru; Tanaka, Takuya; Hashimoto, Noriaki; Haneishi, Hideaki; Batchelor, Tracy T; Gerstner, Elizabeth R; Taylor, Jennie W; Snuderl, Matija; Yagi, Yukako

    2016-10-01

    Computed tomography (CT) and magnetic resonance (MR) imaging have been widely used for visualizing the inside of the human body. However, in many cases, pathological diagnosis is conducted through a biopsy or resection of an organ to evaluate the condition of tissues as definitive diagnosis. To provide more advanced information onto CT or MR image, it is necessary to reveal the relationship between tissue information and image signals. We propose a registration scheme for a set of PT images of divided specimens and a 3D-MR image by reference to an optical macro image (OM image) captured by an optical camera. We conducted a fundamental study using a resected human brain after the death of a brain cancer patient. We constructed two kinds of registration processes using the OM image as the base for both registrations to make conversion parameters between the PT and MR images. The aligned PT images had shapes similar to the OM image. On the other hand, the extracted cross-sectional MR image was similar to the OM image. From these resultant conversion parameters, the corresponding region on the PT image could be searched and displayed when an arbitrary pixel on the MR image was selected. The relationship between the PT and MR images of the whole brain can be analyzed using the proposed method. We confirmed that same regions between the PT and MR images could be searched and displayed using resultant information obtained by the proposed method. In terms of the accuracy of proposed method, the TREs were 0.56±0.39mm and 0.87±0.42mm. We can analyze the relationship between tissue information and MR signals using the proposed method.

  15. Exploiting data redundancy in computational optical imaging.

    Science.gov (United States)

    Munro, Peter R T

    2015-11-30

    We present an algorithm which exploits data redundancy to make computational, coherent, optical imaging more computationally efficient. This algorithm specifically addresses the computation of how light scattered by a sample is collected and coherently detected. It is of greatest benefit in the simulation of broadband optical systems employing coherent detection, such as optical coherence tomography. Although also amenable to time-harmonic data, the algorithm is designed to be embedded within time-domain electromagnetic scattering simulators such as the psuedo-spectral and finite-difference time domain methods. We derive the algorithm in detail as well as criteria which ensure accurate execution of the algorithm. We present simulations that verify the developed algorithm and demonstrate its utility. We expect this algorithm to be important to future developments in computational imaging.

  16. Fast optical imaging of human brain function

    Directory of Open Access Journals (Sweden)

    Gabriele Gratton

    2010-06-01

    Full Text Available Great advancements in brain imaging during the last few decades have opened a large number of new possibilities for neuroscientists. The most dominant methodologies (electrophysiological and magnetic resonance-based methods emphasize temporal and spatial information, respectively. However, theorizing about brain function has recently emphasized the importance of rapid (within 100 ms or so interactions between different elements of complex neuronal networks. Fast optical imaging, and in particular the event-related optical signal (EROS, a technology that has emerged over the last 15 years may provide descriptions of localized (to sub-cm level brain activity with a temporal resolution of less than 100 ms. The main limitations of EROS are its limited penetration, which allows us to image cortical structures not deeper than 3 cm from the surface of the head, and its low signal-to-noise ratio. Advantages include the fact that EROS is compatible with most other imaging methods, including electrophysiological, magnetic resonance, and trans-cranial magnetic stimulation techniques, with which can be recorded concurrently. In this paper we present a summary of the research that has been conducted so far on fast optical imaging, including evidence for the possibility of recording neuronal signals with this method, the properties of the signals, and various examples of applications to the study of human cognitive neuroscience. Extant issues, controversies, and possible future developments are also discussed.

  17. Optical and opto-acoustic imaging.

    Science.gov (United States)

    Ntziachristos, Vasilis; Razansky, Daniel

    2013-01-01

     Since the inception of the microscope, optical imaging is serving the biological discovery for more than four centuries. With the recent emergence of methods appropriate for in vivo staining, such as bioluminescence, fluorescent molecular probes, and proteins, as well as nanoparticle-based targeted agents, significant attention has been shifted toward in vivo interrogations of different dynamic biological processes at the molecular level. This progress has been largely supported by the development of advanced optical tomographic imaging technologies suitable for obtaining volumetric visualization of biomarker distributions in small animals at a whole-body or whole-organ scale, an imaging frontier that is not accessible by the existing tissue-sectioning microscopic techniques due to intensive light scattering beyond the depth of a few hundred microns. Biomedical optoacoustics has also emerged in the recent decade as a powerful tool for high-resolution visualization of optical contrast, overcoming a variety of longstanding limitations imposed by light scattering in deep tissues. By detecting tiny sound vibrations, resulting from selective absorption of light at multiple wavelengths, multispectral optoacoustic tomography methods can now "hear color" in three dimensions, i.e., deliver volumetric spectrally enriched (color) images from deep living tissues at high spatial resolution and in real time. These new-found imaging abilities directly relate to preclinical screening applications in animal models and are foreseen to significantly impact clinical decision making as well.

  18. Review of optical breast imaging and spectroscopy

    Science.gov (United States)

    Grosenick, Dirk; Rinneberg, Herbert; Cubeddu, Rinaldo; Taroni, Paola

    2016-09-01

    Diffuse optical imaging and spectroscopy of the female breast is an area of active research. We review the present status of this field and discuss the broad range of methodologies and applications. Starting with a brief overview on breast physiology, the remodeling of vasculature and extracellular matrix caused by solid tumors is highlighted that is relevant for contrast in optical imaging. Then, the various instrumental techniques and the related methods of data analysis and image generation are described and compared including multimodality instrumentation, fluorescence mammography, broadband spectroscopy, and diffuse correlation spectroscopy. We review the clinical results on functional properties of malignant and benign breast lesions compared to host tissue and discuss the various methods to improve contrast between healthy and diseased tissue, such as enhanced spectroscopic information, dynamic variations of functional properties, pharmacokinetics of extrinsic contrast agents, including the enhanced permeability and retention effect. We discuss research on monitoring neoadjuvant chemotherapy and on breast cancer risk assessment as potential clinical applications of optical breast imaging and spectroscopy. Moreover, we consider new experimental approaches, such as photoacoustic imaging and long-wavelength tissue spectroscopy.

  19. Cloned images and the optical unconscious

    DEFF Research Database (Denmark)

    Romic, Bojana

    , because this young woman had no political/activist record – it was her image that communicated with the world. References: Benjamin, W. (1999) Little History of Photography. in: Jennings, M.W., Eiland, H., Smith, G. (eds) Selected Writings: Volume 2 1927-1934. Cambridge, Massachusetts: The Belknap Press...... that her use of the term is at an angle to Benjamin's: speaking of the modernist optical logic, she retrieves the associationist theory and the notion of memory: 'the only point of recognition within associationist theory that consciousness might be shot through by unconscious conflict...... be stored in a memory of an observer – and later recognised as a pattern (structure) in the another image. The associative process that takes place is usually hidden from the observer, thus the use of the term optical unconscious. As the image gets disseminated via electronic media – 'cloned' is the term...

  20. Fourier optics of image formation in LEEM

    Energy Technology Data Exchange (ETDEWEB)

    Pang, A B; Altman, M S [Department of Physics, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon (Hong Kong); Mueller, Th; Bauer, Ernst [Physikalisches Institute, Technische Universitaet Clausthal, Leibnizstrasse 4, D-38678 Clausthal-Zellerfeld (Germany)

    2009-08-05

    A Fourier optics calculation of image formation in low energy electron microscopy (LEEM) is presented. The adaptation of the existing theory for transmission electron microscopy to the treatment of LEEM and other forms of cathode lens electron microscopy is explained. The calculation incorporates imaging errors that are caused by the objective lens (aberrations), contrast aperture (diffraction), imperfect source characteristics, and voltage and current instabilities. It is used to evaluate the appearance of image features that arise from phase objects such as surface steps and amplitude objects that produce what is alternatively called amplitude, reflectivity or diffraction contrast in LEEM. This formalism can be used after appropriate modification to treat image formation in other emission microscopies. Implications for image formation in the latest aberration-corrected instruments are also discussed.

  1. New contrasts for x-ray imaging and synergy with optical imaging

    Science.gov (United States)

    Wang, Ge

    2017-02-01

    Due to its penetrating power, fine resolution, unique contrast, high-speed, and cost-effectiveness, x-ray imaging is one of the earliest and most popular imaging modalities in biomedical applications. Current x-ray radiographs and CT images are mostly on gray-scale, since they reflect overall energy attenuation. Recent advances in x-ray detection, contrast agent, and image reconstruction technologies have changed our perception and expectation of x-ray imaging capabilities, and generated an increasing interest in imaging biological soft tissues in terms of energy-sensitive material decomposition, phase-contrast, small angle scattering (also referred to as dark-field), x-ray fluorescence and luminescence properties. These are especially relevant to preclinical and mesoscopic studies, and potentially mendable for hybridization with optical molecular tomography. In this article, we review new x-ray imaging techniques as related to optical imaging, suggest some combined x-ray and optical imaging schemes, and discuss our ideas on micro-modulated x-ray luminescence tomography (MXLT) and x-ray modulated opto-genetics (X-Optogenetics).

  2. a Novel Image Registration Algorithm for SAR and Optical Images Based on Virtual Points

    Science.gov (United States)

    Ai, C.; Feng, T.; Wang, J.; Zhang, S.

    2013-07-01

    Optical image is rich in spectral information, while SAR instrument can work in both day and night and obtain images through fog and clouds. Combination of these two types of complementary images shows the great advantages of better image interpretation. Image registration is an inevitable and critical problem for the applications of multi-source remote sensing images, such as image fusion, pattern recognition and change detection. However, the different characteristics between SAR and optical images, which are due to the difference in imaging mechanism and the speckle noises in SAR image, bring great challenges to the multi-source image registration. Therefore, a novel image registration algorithm based on the virtual points, derived from the corresponding region features, is proposed in this paper. Firstly, image classification methods are adopted to extract closed regions from SAR and optical images respectively. Secondly, corresponding region features are matched by constructing cost function with rotate invariant region descriptors such as area, perimeter, and the length of major and minor axes. Thirdly, virtual points derived from corresponding region features, such as the centroids, endpoints and cross points of major and minor axes, are used to calculate initial registration parameters. Finally, the parameters are corrected by an iterative calculation, which will be terminated when the overlap of corresponding region features reaches its maximum. In the experiment, WordView-2 and Radasat-2 with 0.5 m and 4.7 m spatial resolution respectively, obtained in August 2010 in Suzhou, are used to test the registration method. It is shown that the multi-source image registration algorithm presented above is effective, and the accuracy of registration is up to pixel level.

  3. Quantitative contrast-enhanced MR imaging of the optic nerve

    Energy Technology Data Exchange (ETDEWEB)

    Simon, J.H. [Depts. of Radiology, Univ. of Colorado Health Sciences Center, Denver, CO (United States)]|[Iowa Univ., Iowa City, IA (United States); Rubinstein, D. [Depts. of Radiology, Univ. of Colorado Health Sciences Center, Denver, CO (United States)]|[Iowa Univ., Iowa City, IA (United States); Brown, M. [Depts. of Radiology, Univ. of Colorado Health Sciences Center, Denver, CO (United States)]|[Iowa Univ., Iowa City, IA (United States); Yuh, W. [Depts. of Radiology, Univ. of Colorado Health Sciences Center, Denver, CO (United States)]|[Iowa Univ., Iowa City, IA (United States); Birch-Iensen, M. [Depts. of Radiology, Univ. of Colorado Health Sciences Center, Denver, CO (United States)]|[Iowa Univ., Iowa City, IA (United States); Szumowski, J. [Depts. of Radiology, Univ. of Colorado Health Sciences Center, Denver, CO (United States)]|[Iowa Univ., Iowa City, IA (United States); Stears, J. [Depts. of Radiology, Univ. of Colorado Health Sciences Center, Denver, CO (United States)]|[Iowa Univ., Iowa City, IA (United States)

    1994-11-01

    During the acute stages of optic neuritis damage to the blood-optic nerve barrier can be detected using i.v. paramagnetic contrast-enhanced MR imaging. Quantification of the enhancement pattern of the optic nerve, intraorbital fat and muscle was determined in 15 normal subjects using 3 fat-suppression MR imaging methods: T1-weighted spin-echo and spoiled gradient-echo sequences preceded by a flat-frequency selective pulse (FATSAT+SE and FATSAT+SPGR, respectively) and a pulse sequence combining CHOPPER fat suppression with a fat-frequency selective preparation pulse (HYBRID). Pre- and postcontrast-enhanced studies were acquired for FATSAT+SE and FATSAT+SPGR. There was no significant enhancement of the optic nerve by either method (mean increase of 0.96% and 5.3%, respectively), while there was significant enhancement in muscle (mean 118.2% and 108.2%, respectively; p<0.005) and fat (mean increase of 13% and 37%, respectively; p<0.05). Postcontrast optic nerve/muscle signal intensity ratios (mean, SD) were 0.51 (0.07), 0.58 (0.05) and 0.75 (0.05) for FATSAT+SE, FATSAT+SPGR and HYBRID, respectively. These results suggest a practical methodology and range of values for normal signal intensity increases and ratios of tissue signal that can be used as objective measures of optic neuritis for natural history studies and treatment trials. (orig.).

  4. Beam combination schemes and technologies for the Planet Formation Imager (PFI)

    CERN Document Server

    Minardi, Stefano; Berger, Jean-Philippe; Labadie, Lucas; Thomson, Robert R; Haniff, Chris; Ireland, Michael

    2016-01-01

    The Planet Formation Imager (PFI) initiative aims at developing the next generation large scale facility for imaging astronomical optical interferometry operating in the mid-infrared. Here we report on the progress of the Planet Formation Imager Technical Working Group on the beam-combination instruments. We will discuss various available options for the science and fringe-tracker beam combination instruments, ranging from direct imaging, to non-redundant fiber arrays, to integrated optics solutions. Besides considering basic characteristics of the schemes, we will investigate the maturity of the available technological platforms at near- and mid-infrared wavelengths.

  5. Diffusion MR Imaging of Postoperative Bilateral Acute Ischemic Optic Neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Young; Lee, In Ho; Song, Chang June [Chungnam National University Hospital, Daejeon (Korea, Republic of); Hwang, Hee Youn [Eulji University Hospital, Daejeon(Korea, Republic of)

    2012-03-15

    A 57-year-old woman experienced bilateral acute ischemic optic neuropathy after spine surgery. Routine MR imaging sequence, T2-weighted image, showed subtle high signal intensity on bilateral optic nerves. A contrast-enhanced T1 weighted image showed enhancement along the bilateral optic nerve sheath. Moreover, diffusion-weighted image (DWI) and an apparent diffusion coefficient map showed markedly restricted diffusion on bilateral optic nerves. Although MR findings of T2-weighted and contrast enhanced T1-weighted images may be nonspecific, the DWI finding of cytotoxic edema of bilateral optic nerves will be helpful for the diagnosis of acute ischemic optic neuropathy after spine surgery.

  6. Image Retrieval Method for Multiscale Objects from Optical Colonoscopy Images

    Directory of Open Access Journals (Sweden)

    Hirokazu Nosato

    2017-01-01

    Full Text Available Optical colonoscopy is the most common approach to diagnosing bowel diseases through direct colon and rectum inspections. Periodic optical colonoscopy examinations are particularly important for detecting cancers at early stages while still treatable. However, diagnostic accuracy is highly dependent on both the experience and knowledge of the medical doctor. Moreover, it is extremely difficult, even for specialist doctors, to detect the early stages of cancer when obscured by inflammations of the colonic mucosa due to intractable inflammatory bowel diseases, such as ulcerative colitis. Thus, to assist the UC diagnosis, it is necessary to develop a new technology that can retrieve similar cases of diagnostic target image from cases in the past that stored the diagnosed images with various symptoms of colonic mucosa. In order to assist diagnoses with optical colonoscopy, this paper proposes a retrieval method for colonoscopy images that can cope with multiscale objects. The proposed method can retrieve similar colonoscopy images despite varying visible sizes of the target objects. Through three experiments conducted with real clinical colonoscopy images, we demonstrate that the method is able to retrieve objects of any visible size and any location at a high level of accuracy.

  7. Integrated optical coherence tomography and optical coherence microscopy imaging of human pathology

    Science.gov (United States)

    Lee, Hsiang-Chieh; Zhou, Chao; Wang, Yihong; Aquirre, Aaron D.; Tsai, Tsung-Han; Cohen, David W.; Connolly, James L.; Fujimoto, James G.

    2010-02-01

    Excisional biopsy is the current gold standard for disease diagnosis; however, it requires a relatively long processing time and it may also suffer from unacceptable false negative rates due to sampling errors. Optical coherence tomography (OCT) is a promising imaging technique that provide real-time, high resolution and three-dimensional (3D) images of tissue morphology. Optical coherence microscopy (OCM) is an extension of OCT, combining both the coherence gating and the confocal gating techniques. OCM imaging achieves cellular resolution with deeper imaging depth compared to confocal microscopy. An integrated OCT/OCM imaging system can provide co-registered multiscale imaging of tissue morphology. 3D-OCT provides architectural information with a large field of view and can be used to find regions of interest; while OCM provides high magnification to enable cellular imaging. The integrated OCT/OCM system has an axial resolution of kidney (19), were imaged with OCT and OCM within 2 to 6 hours after excision. The images were compared with H & E histology to identify characteristic features useful for disease diagnosis. The feasibility of visualizing human pathology using integrated OCT/OCM was demonstrated in the pathology laboratory settings.

  8. Optical coherence tomography for endodontic imaging

    Science.gov (United States)

    van Soest, G.; Shemesh, H.; Wu, M.-K.; van der Sluis, L. W. M.; Wesselink, P. R.

    2008-02-01

    In root canal therapy, complications frequently arise as a result of root fracture or imperfect cleaning of fins and invaginations. To date, there is no imaging method for nondestructive in vivo evaluation of the condition of the root canal, during or after treatment. There is a clinical need for a technique to detect defects before they give rise to complications. In this study we evaluate the ability of optical coherence tomography (OCT) to image root canal walls, and its capacity to identify complicating factors in root canal treatment. While the potential of OCT to identify caries has been explored before, endodontic imaging has not been reported. We imaged extracted lower front teeth after endodontic preparation and correlated these images to histological sections. A 3D OCT pullback scan was made with an endoscopic rotating optical fiber probe inside the root canal. All oval canals, uncleaned fins, risk zones, and one perforation that were detected by histology were also imaged by OCT. As an example of an area where OCT has clinical potential, we present a study of vertical root fracture identification with OCT.

  9. Physical Optics Based Computational Imaging Systems

    Science.gov (United States)

    Olivas, Stephen Joseph

    There is an ongoing demand on behalf of the consumer, medical and military industries to make lighter weight, higher resolution, wider field-of-view and extended depth-of-focus cameras. This leads to design trade-offs between performance and cost, be it size, weight, power, or expense. This has brought attention to finding new ways to extend the design space while adhering to cost constraints. Extending the functionality of an imager in order to achieve extraordinary performance is a common theme of computational imaging, a field of study which uses additional hardware along with tailored algorithms to formulate and solve inverse problems in imaging. This dissertation details four specific systems within this emerging field: a Fiber Bundle Relayed Imaging System, an Extended Depth-of-Focus Imaging System, a Platform Motion Blur Image Restoration System, and a Compressive Imaging System. The Fiber Bundle Relayed Imaging System is part of a larger project, where the work presented in this thesis was to use image processing techniques to mitigate problems inherent to fiber bundle image relay and then, form high-resolution wide field-of-view panoramas captured from multiple sensors within a custom state-of-the-art imager. The Extended Depth-of-Focus System goals were to characterize the angular and depth dependence of the PSF of a focal swept imager in order to increase the acceptably focused imaged scene depth. The goal of the Platform Motion Blur Image Restoration System was to build a system that can capture a high signal-to-noise ratio (SNR), long-exposure image which is inherently blurred while at the same time capturing motion data using additional optical sensors in order to deblur the degraded images. Lastly, the objective of the Compressive Imager was to design and build a system functionally similar to the Single Pixel Camera and use it to test new sampling methods for image generation and to characterize it against a traditional camera. These computational

  10. A combined near field optical and force microscope

    NARCIS (Netherlands)

    Moers, M.H.P.; Tack, R.G.; Hulst, van N.F.; Bölger, B.

    1993-01-01

    Scanning near field optical microscopy (SNOM) is the optical alternative of the scanning probe microscopical techniques which enables a lateral resolution down to about 10 nm, unlimited by diffraction. Moreover, the potential of non- destructive imaging of chemical and biological samples with nanome

  11. Special issue on high-resolution optical imaging

    Science.gov (United States)

    Smith, Peter J. S.; Davis, Ilan; Galbraith, Catherine G.; Stemmer, Andreas

    2013-09-01

    The pace of development in the field of advanced microscopy is truly breath-taking, and is leading to major breakthroughs in our understanding of molecular machines and cell function. This special issue of Journal of Optics draws attention to a number of interesting approaches, ranging from fluorescence and imaging of unlabelled cells, to computational methods, all of which are describing the ever increasing detail of the dynamic behaviour of molecules in the living cell. This is a field which traditionally, and currently, demonstrates a marvellous interplay between the disciplines of physics, chemistry and biology, where apparent boundaries to resolution dissolve and living cells are viewed in ever more clarity. It is fertile ground for those interested in optics and non-conventional imaging to contribute high-impact outputs in the fields of cell biology and biomedicine. The series of articles presented here has been selected to demonstrate this interdisciplinarity and to encourage all those with a background in the physical sciences to 'dip their toes' into the exciting and dynamic discoveries surrounding cell function. Although single molecule super-resolution microscopy is commercially available, specimen preparation and interpretation of single molecule data remain a major challenge for scientists wanting to adopt the techniques. The paper by Allen and Davidson [1] provides a much needed detailed introduction to the practical aspects of stochastic optical reconstruction microscopy, including sample preparation, image acquisition and image analysis, as well as a brief description of the different variants of single molecule localization microscopy. Since super-resolution microscopy is no longer restricted to three-dimensional imaging of fixed samples, the review by Fiolka [2] is a timely introduction to techniques that have been successfully applied to four-dimensional live cell super-resolution microscopy. The combination of multiple high-resolution techniques

  12. Wideband Optical Detector of Ultrasound for Medical Imaging Applications

    Science.gov (United States)

    Rosenthal, Amir; Kellnberger, Stephan; Omar, Murad; Razansky, Daniel; Ntziachristos, Vasilis

    2014-01-01

    Optical sensors of ultrasound are a promising alternative to piezoelectric techniques, as has been recently demonstrated in the field of optoacoustic imaging. In medical applications, one of the major limitations of optical sensing technology is its susceptibility to environmental conditions, e.g. changes in pressure and temperature, which may saturate the detection. Additionally, the clinical environment often imposes stringent limits on the size and robustness of the sensor. In this work, the combination of pulse interferometry and fiber-based optical sensing is demonstrated for ultrasound detection. Pulse interferometry enables robust performance of the readout system in the presence of rapid variations in the environmental conditions, whereas the use of all-fiber technology leads to a mechanically flexible sensing element compatible with highly demanding medical applications such as intravascular imaging. In order to achieve a short sensor length, a pi-phase-shifted fiber Bragg grating is used, which acts as a resonator trapping light over an effective length of 350 µm. To enable high bandwidth, the sensor is used for sideway detection of ultrasound, which is highly beneficial in circumferential imaging geometries such as intravascular imaging. An optoacoustic imaging setup is used to determine the response of the sensor for acoustic point sources at different positions. PMID:24895083

  13. Generalized pupil aberrations of optical imaging systems

    Science.gov (United States)

    Elazhary, Tamer T.

    In this dissertation fully general conditions are presented to correct linear and quadratic field dependent aberrations that do not use any symmetry. They accurately predict the change in imaging aberrations in the presence of lower order field dependent aberrations. The definitions of the image, object, and coordinate system are completely arbitrary. These conditions are derived using a differential operator on the scalar wavefront function. The relationships are verified using ray trace simulations of a number of systems with varying degrees of complexity. The math is shown to be extendable to provide full expansion of the scalar aberration function about field. These conditions are used to guide the design of imaging systems starting with only paraxial surface patches, then growing freeform surfaces that maintain the analytic conditions satisfied for each point in the pupil. Two methods are proposed for the design of axisymmetric and plane symmetric optical imaging systems. Design examples are presented as a proof of the concept.

  14. Image Distortion of Optical Coherence Tomography

    Institute of Scientific and Technical Information of China (English)

    安源; 姚建铨

    2004-01-01

    A kind of image distortion in Optical Coherence Tomography (OCT) resulted from average refractive index changes between structures of bio-tissue is discussed for the first time.Analysis is given on following situations:1) Exact refraction index changes between microstructures;2)The gradient of average refractive index change between different tissue layers is parallel to the probe beam;3) The gradient of average refractive index change is vertical to the probe beam.The results show that the image distortion of situation 1) is usually negligible;in situation 2) there is a spread or shrink effect without relative location error; however,in situation 3) there is a significant image error inducing relative location displacement between different structures.Preliminary design to eliminate the distortion is presented,the method of which mainly based on the image classification and pixel array re-arrangement.

  15. 7th International Workshop on Advanced Optical Imaging and Metrology

    CERN Document Server

    2014-01-01

    In continuation of the FRINGE Workshop Series this Proceeding contains all contributions presented at the 7. International Workshop on Advanced Optical Imaging and Metrology. The FRINGE Workshop Series is dedicated to the presentation, discussion and dissemination of recent results in Optical Imaging and Metrology. Topics of particular interest for the 7. Workshop are: - New methods and tools for the generation, acquisition, processing, and evaluation of data in Optical Imaging and Metrology (digital wavefront engineering, computational imaging, model-based reconstruction, compressed sensing, inverse problems solution) - Application-driven technologies in Optical Imaging and Metrology (high-resolution, adaptive, active, robust, reliable, flexible, in-line, real-time) - High-dynamic range solutions in Optical Imaging and Metrology (from macro to nano) - Hybrid technologies in Optical Imaging and Metrology (hybrid optics, sensor and data fusion, model-based solutions, multimodality) - New optical sensors, imagi...

  16. Novel optical system for neonatal brain imaging

    Science.gov (United States)

    Chen, Yu; Zhou, Shuoming; Nioka, Shoko; Chance, Britton; Anday, Endla; Ravishankar, Sudha; Delivoria-Papadopoulos, Maria

    1999-03-01

    A highly portable, fast, safe and affordable imaging system that provides interpretable images of brain function in full- and pre-term neonates within a few seconds has been applied to neonates with normal and pathological states. We have used a uniquely sensitive optical tomography system, termed phased array, which has revealed significant functional responses, particularly to parietal stimulation in neonate brain. This system can indicate the blood concentration and oxygenation change during the parietal brain activation in full- and pre-term neonates. The preliminary clinical results, especially a longitudinal study of a cardiac arrest neonate, suggest a variety of future applications.

  17. Optical cell sorting with multiple imaging modalities

    DEFF Research Database (Denmark)

    Banas, Andrew; Carrissemoux, Caro; Palima, Darwin

    2017-01-01

    techniques. Scattering forces from beams actuated via efficient phase-only efficient modulation has been adopted. This has lowered the required power for sorting cells to a tenth of our previous approach, and also makes the cell sorter safer for use in clinical settings. With the versatility of dynamically...... programmable phase spatial light modulators, a plurality of light shaping techniques, including hybrid approaches, can be utilized in cell sorting....... healthy cells. With the richness of visual information, a lot of microscopy techniques have been developed and have been crucial in biological studies. To utilize their complementary advantages we adopt both fluorescence and brightfield imaging in our optical cell sorter. Brightfield imaging has...

  18. Electro-optic imaging Fourier transform spectrometer

    Science.gov (United States)

    Chao, Tien-Hsin (Inventor); Znod, Hanying (Inventor)

    2009-01-01

    An Electro-Optic Imaging Fourier Transform Spectrometer (EOIFTS) for Hyperspectral Imaging is described. The EOIFTS includes an input polarizer, an output polarizer, and a plurality of birefringent phase elements. The relative orientations of the polarizers and birefringent phase elements can be changed mechanically or via a controller, using ferroelectric liquid crystals, to substantially measure the spectral Fourier components of light propagating through the EIOFTS. When achromatic switches are used as an integral part of the birefringent phase elements, the EIOFTS becomes suitable for broadband applications, with over 1 micron infrared bandwidth.

  19. Magneto-optical imaging of exotic superconductors

    Science.gov (United States)

    van der Beek, C. J.; Losco, J.; Konczykowski, M.; Pari, P.; Shibauchi, T.; Shishido, H.; Matsuda, Y.

    2009-02-01

    We have constructed a novel compact cryostat for optical measurements at temperatures below 2 K. The desktop cryostat, small enough to be placed under the objective of a standard commercial polarized light microscope, functions in a single shot mode, with a five hour autonomy at 1.5 K. Central to its conception are four charcoal pumps for adsorption and desorption of He contained in a closed circuit, and novel thermal switches allowing for thermalization of the pumps and of the two 1 K pots. The latter are connected to the 1" diameter sample holder through braids. Sample access is immediate, through the simple removal of the optical windows. In this contribution, we shall present first results on magneto-optical imaging of flux penetration in the heavy-fermion superconductor CeCoIn5.

  20. Polymerized LB Films Imaged with a Combined Atomic Force Microscope-Fluorescence Microscope

    NARCIS (Netherlands)

    Putman, C.A.J.; Putman, Constant A.J.; Hansma, Helen G.; Gaub, Hermann E.; Hansma, Paul K.

    1992-01-01

    The first results obtained with a new stand-alone atomic force microscope (AFM) integrated with a standard Zeiss optical fluorescence microscope are presented. The optical microscope allows location and selection of objects to be imaged with the high-resolution AFM. Furthermore, the combined

  1. Polymerized LB films imaged with a combined atomic force microscope-fluorescence microscope

    NARCIS (Netherlands)

    Putman, Constant A.J.; Hansma, Helen G.; Gaub, Hermann E.; Hansma, Paul K.

    1992-01-01

    The first results obtained with a new stand-alone atomic force microscope (AFM) integrated with a standard Zeiss optical fluorescence microscope are presented. The optical microscope allows location and selection of objects to be imaged with the high-resolution AFM. Furthermore, the combined microsc

  2. Detection in urban scenario using combined airborne imaging sensors

    Science.gov (United States)

    Renhorn, Ingmar; Axelsson, Maria; Benoist, Koen; Bourghys, Dirk; Boucher, Yannick; Briottet, Xavier; De Ceglie, Sergio; Dekker, Rob; Dimmeler, Alwin; Dost, Remco; Friman, Ola; Kåsen, Ingebjørg; Maerker, Jochen; van Persie, Mark; Resta, Salvatore; Schwering, Piet; Shimoni, Michal; Haavardsholm, Trym Vegard

    2012-06-01

    The EDA project "Detection in Urban scenario using Combined Airborne imaging Sensors" (DUCAS) is in progress. The aim of the project is to investigate the potential benefit of combined high spatial and spectral resolution airborne imagery for several defense applications in the urban area. The project is taking advantage of the combined resources from 7 contributing nations within the EDA framework. An extensive field trial has been carried out in the city of Zeebrugge at the Belgian coast in June 2011. The Belgian armed forces contributed with platforms, weapons, personnel (soldiers) and logistics for the trial. Ground truth measurements with respect to geometrical characteristics, optical material properties and weather conditions were obtained in addition to hyperspectral, multispectral and high resolution spatial imagery. High spectral/spatial resolution sensor data are used for detection, classification, identification and tracking.

  3. IOT Overview: Optical Spectro-Imagers

    Science.gov (United States)

    Patat, F.

    Taking the FORS instruments as a representative case, I review the Calibration Plan for optical spectro-imagers currently offered at ESO, discussing various aspects related both to the scientific outcome and the instrument/site monitoring. I also describe ongoing and future calibration projects planned by the Instrument Operations Teams, trying to give an objective view on the limitations of the Calibration Plans currently implemented at ESO for this class of instruments.

  4. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics.

    Science.gov (United States)

    Sun, Tianxi; Macdonald, C A

    2013-02-07

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens.

  5. Simulation of electro-optical imaging system based on OpenGL

    Science.gov (United States)

    Zhu, Yong; Fu, Qiang; Duan, Jin; Jing, Wen-bo

    2013-08-01

    With the development of electro-optical imaging system technology and simulation technology, and the demand of optimizing the new type electro-optical imaging system theoretical model, more and more scientific research institutes, colleges and universities research on the simulation of electro-optical imaging system, and the better results were obtained. Simulation technology saved the cost of system design development, meanwhile, some complex and hard to re-implement experiments can be carried repeatedly. According to the demand of complex environment construction technology and the requirement of imaging simulation system fidelity, considering the performance of electro-optical imaging system, an electro-optical imaging system is modeled. The modeling has two aspects which is scene characteristic modeling and electro-optical system modeling. Scene characteristic modeling can construct dynamic scenes in different kinds of complex environments by using powerful OpenGL three-dimension model visualization technology. Electro-optical system modeling is consist of optical system and imaging detector. Electro-optical imaging system simulation model is established with the analysis of electro-optical imaging system theory. The use of modular design concept and general interface technology is combined. Different imaging effect is received under different parameters by modifying the model's related parameters. The experimental results show that, the image produced from simulation basically reflects the performance of imaging system, so this kind of image can be used as a information source for imaging system performance analysis. It provides a simple and feasible method for the analysis of imaging system performance, which has a very important practical significance.

  6. Computational optical sensing and imaging: introduction to feature issue.

    Science.gov (United States)

    Gerwe, David R; Harvey, Andrew; Gehm, Michael E

    2013-04-01

    The 2012 Computational Optical Sensing and Imaging (COSI) conference of the Optical Society of America was one of six colocated meetings composing the Imaging and Applied Optics Congress held in Monterey, California, 24-28 June. COSI, together with the Imaging Systems and Applications, Optical Sensors, Applied Industrial Optics, and Optical Remote Sensing of the Environment conferences, brought together a diverse group of scientists and engineers sharing a common interest in measuring and processing of information carried by optical fields. This special feature includes several papers based on presentations given at the 2012 COSI conference as well as independent contributions, which together highlight several important trends.

  7. Laryngeal imaging with polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Burns, James A.; Kim, Ki Hean; Anderson, R. Rox

    2011-03-01

    Objectives/Hypothesis: Optical coherence tomography (OCT), an imaging technology that provides crosssectional subsurface tissue structure images using backscattered light, is a promising noninvasive, imaging modality for in-vivo assessment of vocal fold layered microstructure. Polarization-sensitive OCT (PS-OCT) augments conventional OCT by detecting changes in the polarization state of reflected light. This study imaged various benign laryngeal pathologies in patients undergoing direct laryngoscopy under general anesthesia to determine whether PS-OCT would provide useful additional information about vocal fold microstructure and glottic surface pathology. Study Design:Prospective clinical trial. Methods: Eighteen patients who were undergoing microlaryngoscopy under general anesthesia for benign glottic disease were imaged bilaterally with OCT and PS-OCT (N=34 vocal folds). Intraoperative microphotography guided placement of the imaging probe. Normalappearing glottic tissue was also imaged if present. When clinically indicated, biopsy or complete removal of the lesion established histologic confirmation. Results: PS-OCT provided high quality, vertical, cross-sectional images up to 1.2mm deep that complemented microlaryngoscopy, and conventional OCT for vocal fold pathologies. Scar tissue was visualized by PS-OCT, characterized by a birefringence pattern more intense than that of normal glottic tissue. Conclusions: Combining PS-OCT with OCT during human vocal cord imaging provides useful information in characterizing vocal cord lesions, particularly scar tissue.

  8. A Stochastic Approach for Blurred Image Restoration and Optical Flow Computation on Field Image Sequence

    Institute of Scientific and Technical Information of China (English)

    高文; 陈熙霖

    1997-01-01

    The blur in target images caused by camera vibration due to robot motion or hand shaking and by object(s) moving in the background scene is different to deal with in the computer vision system.In this paper,the authors study the relation model between motion and blur in the case of object motion existing in video image sequence,and work on a practical computation algorithm for both motion analysis and blut image restoration.Combining the general optical flow and stochastic process,the paper presents and approach by which the motion velocity can be calculated from blurred images.On the other hand,the blurred image can also be restored using the obtained motion information.For solving a problem with small motion limitation on the general optical flow computation,a multiresolution optical flow algoritm based on MAP estimation is proposed. For restoring the blurred image ,an iteration algorithm and the obtained motion velocity are used.The experiment shows that the proposed approach for both motion velocity computation and blurred image restoration works well.

  9. Optical encryption using photon-counting polarimetric imaging.

    Science.gov (United States)

    Maluenda, David; Carnicer, Artur; Martínez-Herrero, Rosario; Juvells, Ignasi; Javidi, Bahram

    2015-01-26

    We present a polarimetric-based optical encoder for image encryption and verification. A system for generating random polarized vector keys based on a Mach-Zehnder configuration combined with translucent liquid crystal displays in each path of the interferometer is developed. Polarization information of the encrypted signal is retrieved by taking advantage of the information provided by the Stokes parameters. Moreover, photon-counting model is used in the encryption process which provides data sparseness and nonlinear transformation to enhance security. An authorized user with access to the polarization keys and the optical design variables can retrieve and validate the photon-counting plain-text. Optical experimental results demonstrate the feasibility of the encryption method.

  10. High efficiency coherent beam combining of semiconductor optical amplifiers.

    Science.gov (United States)

    Creedon, Kevin J; Redmond, Shawn M; Smith, Gary M; Missaggia, Leo J; Connors, Michael K; Kansky, Jan E; Fan, Tso Yee; Turner, George W; Sanchez-Rubio, Antonio

    2012-12-01

    We demonstrate 40 W coherently combined output power in a single diffraction-limited beam from a one-dimensional 47-element array of angled-facet slab-coupled optical waveguide amplifiers at 1064 nm. The output from each emitter was collimated and overlapped onto a diffractive optical element combiner using a common transform lens. Phase locking was achieved via active feedback on each amplifier's drive current to maximize the power in the combined beam. The combining efficiency at all current levels was nearly constant at 87%.

  11. Imaging Granulomatous Lesions with Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Christina Banzhaf

    2012-01-01

    Full Text Available Aim: To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT images and compare this to previous studies of nonmelanoma skin tumors. Methods: Two patients with granulomas, tophi and granuloma annulare (GA, respectively, were photographed digitally, OCT-scanned and biopsied in the said order. Normal skin was OCT-scanned for comparison, but not biopsied. The OCT images from each lesion were compared with their histologic images as well as with OCT images with similar characteristics obtained from nonmelanoma skin tumors. Results: The OCT images of the tophi showed hyperreflective, rounded cloud-like structures in dermis, their upper part sharply delineated by a hyporeflective fringe. The deeper areas appeared blurred. The crystalline structures were delineated by a hyporeflective fringe. OCT images of GA showed two different structures in dermis: a hyporeflective rounded one, and one that was lobulated and wing-like. Conclusion: Granulomatous tissue surrounding urate deposits appeared as a clear hyporeflective fringe surrounding a light, hyperreflective area. The urate crystals appeared as hyperreflective areas, shielding the deeper part of dermis, meaning OCT could only visualize the upper part of the lesions. The lobulated, wing-like structure in GA may resemble diffuse GA or a dense lymphocytic infiltrate as seen on histology. The rounded structure in GA may represent an actual granuloma or either diffuse GA or a dense lymphocytic infiltrate as described above. This case suggests that OCT images granulomatous tissue as absorbent, hyporeflective areas, and urate crystals appear as reflective areas, obscuring the underlying tissue. In GA a new image shape looking like a wing has been found. The frequency, specificity and sensitivity of this new pattern in OCT imaging will require further studies.

  12. Luminescent probes for optical in vivo imaging

    Science.gov (United States)

    Texier, Isabelle; Josserand, Veronique; Garanger, Elisabeth; Razkin, Jesus; Jin, Zhaohui; Dumy, Pascal; Favrot, Marie; Boturyn, Didier; Coll, Jean-Luc

    2005-04-01

    Going along with instrumental development for small animal fluorescence in vivo imaging, we are developing molecular fluorescent probes, especially for tumor targeting. Several criteria have to be taken into account for the optimization of the luminescent label. It should be adapted to the in vivo imaging optical conditions : red-shifted absorption and emission, limited overlap between absorption and emission for a good signal filtering, optimized luminescence quantum yield, limited photo-bleaching. Moreover, the whole probe should fulfill the biological requirements for in vivo labeling : adapted blood-time circulation, biological conditions compatibility, low toxicity. We here demonstrate the ability of the imaging fluorescence set-up developed in LETI to image the bio-distribution of molecular probes on short times after injection. Targeting with Cy5 labeled holo-transferrin of subcutaneous TS/Apc (angiogenic murine breast carcinoma model) or IGROV1 (human ovarian cancer) tumors was achieved. Differences in the kinetics of the protein uptake by the tumors were evidenced. IGROV1 internal metastatic nodes implanted in the peritoneal cavity could be detected in nude mice. However, targeted metastatic nodes in lung cancer could only be imaged after dissection of the mouse. These results validate our fluorescence imaging set-up and the use of Cy5 as a luminescent label. New fluorescent probes based on this dye and a molecular delivery template (the RAFT molecule) can thus be envisioned.

  13. Compressive optical image watermarking using joint Fresnel transform correlator architecture

    Science.gov (United States)

    Li, Jun; Zhong, Ting; Dai, Xiaofang; Yang, Chanxia; Li, Rong; Tang, Zhilie

    2017-02-01

    A new optical image watermarking technique based on compressive sensing using joint Fresnel transform correlator architecture has been presented. A secret scene or image is first embedded into a host image to perform optical image watermarking by use of joint Fresnel transform correlator architecture. Then, the watermarked image is compressed to much smaller signal data using single-pixel compressive holographic imaging in optical domain. At the received terminal, the watermarked image is reconstructed well via compressive sensing theory and a specified holographic reconstruction algorithm. The preliminary numerical simulations show that it is effective and suitable for optical image security transmission in the coming absolutely optical network for the reason of the completely optical implementation and largely decreased holograms data volume.

  14. Optical Brain Imaging: A Powerful Tool for Neuroscience.

    Science.gov (United States)

    Zhu, Xinpei; Xia, Yanfang; Wang, Xuecen; Si, Ke; Gong, Wei

    2017-02-01

    As the control center of organisms, the brain remains little understood due to its complexity. Taking advantage of imaging methods, scientists have found an accessible approach to unraveling the mystery of neuroscience. Among these methods, optical imaging techniques are widely used due to their high molecular specificity and single-molecule sensitivity. Here, we overview several optical imaging techniques in neuroscience of recent years, including brain clearing, the micro-optical sectioning tomography system, and deep tissue imaging.

  15. Nanoscale optical imaging of semiconductor nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Boehmler, Miriam; Hartschuh, Achim [Department Chemie, CeNS, Ludwig-Maximilians-Universitaet Muenchen (Germany); Myalitsin, Anton; Mews, Alf [Department Chemie, Universitaet Hamburg (Germany)

    2011-07-01

    Inorganic semiconducting nanowires (NWs) feature size-related optical properties which make them interesting for a wide range of applications, e.g. nanoscale optoelectronics, sensors, and photovoltaics. Their relevant length scales that are determined by nanowire diameter and exciton Bohr radius, however, can not be resolved by conventional diffraction limited methods. We illustrate the prospects of tip-enhanced near-field optical microscopy (TENOM) as a method to investigate single nanowires. In TENOM a sharp metallic tip acts as optical antenna thereby enhancing the detected signal and increasing the optical resolution to about 15 nm. We present our investigations of CdSe NWs which have been grown by the wet chemical solution liquid solid technique. Here, TENOM provides the possibility to simultaneously image photoluminescence (PL) as well as Raman scattering of individual NWs with nanoscale resolution. We observe spatial variations of the PL intensity and energy on a length scale of about 15 nm indicating crystal phase transitions and diameter fluctuations.

  16. Performance of laser based optical imaging system

    Science.gov (United States)

    Shah, Dhrupesh S.; Banerjee, Arup; Vora, Anup; Biswas, Amiya; Patel, Naimesh; Kurulkar, Amit; Dutt, Ashutosh

    2016-05-01

    Day night imaging application requires high dynamic range optical imaging system to detect targets of interest covering mid-day (>32000 Lux)[1], and moonless night ( 1mLux)[1] under clear sky- (visibility of >10km, atmospheric loss of 500m, atmospheric loss of >15dB/Km) conditions. Major governing factors for development of such camera systems are (i) covert imaging with ability to identify the target, (ii) imaging irrespective to the scene background, (iii) reliable operation , (iv) imaging capabilities in inclement weather conditions, (v) resource requirement vs availability power & mass, (vi) real-time data processing, (vii) self-calibration, and (viii) cost. Identification of optimum spectral band of interest is most important to meet these requirements. Conventional detection systems sensing in MWIR and LWIR band has certain draw backs in terms of target detection capabilities, susceptibility to background and huge thermo-mechanical resource requirement. Alternatively, range gated imaging camera system sensing in NIR/SWIR spectrum has shown significant potential to detect wide dynamic range targets. ToF Camera configured in NIR band has certain advantages in terms of Focal Plane Assembly (FPA) development with large format detectors and thermo-mechanical resource requirement compared to SWIR band camera configuration. In past, ToF camera systems were successfully configured in NIR spectrum using silicon based Electron Multiplying CCD (EMCCD), Intensifier CCD (ICCD) along with Gating device and pulsed laser source having emission in between 800nm to 900nm. However, these systems have a very low dynamic range and not suitable for clear sky mid-day conditions. Recently silicon based scientific grade CMOS image sensors have shown significant improvement in terms of high NIR responsivity and available in bigger formats (5MP or more), adequate Full well capacity for day time imaging (>30Ke), very low readout noise (<2e) required for night imaging and higher frame

  17. Adaptive optics scanning laser ophthalmoscope imaging: technology update

    Directory of Open Access Journals (Sweden)

    Merino D

    2016-04-01

    Full Text Available David Merino, Pablo Loza-Alvarez The Institute of Photonic Sciences (ICFO, The Barcelona Institute of Science and Technology, Castelldefels, Barcelona, Spain Abstract: Adaptive optics (AO retinal imaging has become very popular in the past few years, especially within the ophthalmic research community. Several different retinal techniques, such as fundus imaging cameras or optical coherence tomography systems, have been coupled with AO in order to produce impressive images showing individual cell mosaics over different layers of the in vivo human retina. The combination of AO with scanning laser ophthalmoscopy has been extensively used to generate impressive images of the human retina with unprecedented resolution, showing individual photoreceptor cells, retinal pigment epithelium cells, as well as microscopic capillary vessels, or the nerve fiber layer. Over the past few years, the technique has evolved to develop several different applications not only in the clinic but also in different animal models, thanks to technological developments in the field. These developments have specific applications to different fields of investigation, which are not limited to the study of retinal diseases but also to the understanding of the retinal function and vision science. This review is an attempt to summarize these developments in an understandable and brief manner in order to guide the reader into the possibilities that AO scanning laser ophthalmoscopy offers, as well as its limitations, which should be taken into account when planning on using it. Keywords: high-resolution, in vivo retinal imaging, AOSLO

  18. Study Of The Theory Of Optical Stabilizing Image

    Science.gov (United States)

    Zhijian, Wang; Jianping, Zheng

    1989-01-01

    In this paper, all varieties of the optical stabilizing image methods have been summarized into an optical stabilization pattern, and a mathematical model of the optical stabilizing image are proposed. Some representative systems are analyzed by means of this model in orde to show how to use this model.

  19. Optical Methods and Instrumentation in Brain Imaging and Therapy

    CERN Document Server

    2013-01-01

    This book provides a comprehensive up-to-date review of optical approaches used in brain imaging and therapy. It covers a variety of imaging techniques including diffuse optical imaging, laser speckle imaging, photoacoustic imaging and optical coherence tomography. A number of laser-based therapeutic approaches are reviewed, including photodynamic therapy, fluorescence guided resection and photothermal therapy. Fundamental principles and instrumentation are discussed for each imaging and therapeutic technique. Represents the first publication dedicated solely to optical diagnostics and therapeutics in the brain Provides a comprehensive review of the principles of each imaging/therapeutic modality Reviews the latest advances in instrumentation for optical diagnostics in the brain Discusses new optical-based therapeutic approaches for brain diseases

  20. Design parameters for wearable optical imagers

    Science.gov (United States)

    Akin, Ata; Kim, Sanghyun; Pourrezaei, Kambiz; Chance, Britton; Nioka, Shoko

    2001-06-01

    This paper summarizes the design steps that are followed during the development of the portable optical imager for breast cancer screening. The design steps considered the parameters such as total power consumption versus battery weight and size, speed of data acquisition versus cost and complexity of the design (functionality), graphical display versus operating system choice. We have used a single board computer system that uses Windows CE as the real time operating system. This choice was preferred since our graphical display requirements can only be carried out with the CE environment's GUI kernels.

  1. Optical and opto-acoustic interventional imaging.

    Science.gov (United States)

    Sarantopoulos, Athanasios; Beziere, Nicolas; Ntziachristos, Vasilis

    2012-02-01

    Many clinical interventional procedures, such as surgery or endoscopy, are today still guided by human vision and perception. Human vision however is not sensitive or accurate in detecting a large range of disease biomarkers, for example cellular or molecular processes characteristic of disease. For this reason advanced optical and opto-acoustic (photo-acoustic) methods are considered for enabling a more versatile, sensitive and accurate detection of disease biomarkers and complement human vision in clinical decision making during interventions. Herein, we outline developments in emerging fluorescence and opto-acoustic sensing and imaging techniques that can lead to practical implementations toward improving interventional vision.

  2. Smart optical coherence tomography for ultra-deep imaging through highly scattering media

    CERN Document Server

    Badon, Amaury; Lerosey, Geoffroy; Boccara, Albert C; Fink, Mathias; Aubry, Alexandre

    2015-01-01

    Multiple scattering of waves in disordered media is a nightmare whether it be for detection or imaging purposes. The best approach so far to get rid of multiple scattering is optical coherence tomography. It basically combines confocal microscopy and coherence time-gating to discriminate ballistic photons from a predominant multiple scattering background. Nevertheless, the imaging depth range remains limited to 1 mm at best in human soft tissues. Here we propose a matrix approach of optical imaging to push back this fundamental limit. By combining a matrix discrimination of ballistic waves and iterative time-reversal, we show both theoretically and experimentally an extension of the imaging-depth limit by at least a factor two compared to optical coherence tomography. In particular, the reported experiment demonstrates imaging through a strongly scattering layer from which only one reflected photon over 1000 billion is ballistic. This approach opens a new route towards ultra-deep tissue imaging.

  3. Acoustic and optical borehole-wall imaging for fractured-rock aquifer studies

    Science.gov (United States)

    Williams, J.H.; Johnson, C.D.

    2004-01-01

    Imaging with acoustic and optical televiewers results in continuous and oriented 360?? views of the borehole wall from which the character, relation, and orientation of lithologic and structural planar features can be defined for studies of fractured-rock aquifers. Fractures are more clearly defined under a wider range of conditions on acoustic images than on optical images including dark-colored rocks, cloudy borehole water, and coated borehole walls. However, optical images allow for the direct viewing of the character of and relation between lithology, fractures, foliation, and bedding. The most powerful approach is the combined application of acoustic and optical imaging with integrated interpretation. Imaging of the borehole wall provides information useful for the collection and interpretation of flowmeter and other geophysical logs, core samples, and hydraulic and water-quality data from packer testing and monitoring. ?? 2003 Elsevier B.V. All rights reserved.

  4. Research on the methods of optical image hiding based on double random phase encoding and digital holography

    Science.gov (United States)

    Xu, Hongsheng; Sang, Nong

    2011-12-01

    Optical information hiding system has many features such as high processing speed, high parallel, high encryption dimension and high speed of optical transformation and related operations, more advantages than digital method in some way. But it has not adequate security, and enough combination with techniques of digital image processing. So on basis of analyzing existing image hiding and analyzing techniques, we give out the idea. We should adopt idea of virtual optics on the way of all-digital simulation to do research of optical image hiding and analyzing methods based on optical image processing technique especially technique of double random phase encoding and digital holography.

  5. Optical image segmentation using wavelet filtering techniques

    Science.gov (United States)

    Veronin, Christopher P.

    1990-12-01

    This research effort successfully implemented an automatic, optically based image segmentation scheme for locating potential targets in a cluttered FLIR image. Such a design is critical to achieve real-time segmentation and classification for machine vision applications. The segmentation scheme used in this research was based on texture discrimination and employs orientation specific, bandpass spatial filters as its main component. The orientation specific, bandpass spatial filters designed during this research include symmetrically located circular apertures implemented on heavy, black aluminum foil; cosine and sine Gabor filters implemented with detour-phase computer generated holography photoreduced onto glass slides; and symmetrically located circular apertures implemented on a liquid crystal television (LCTV) for real-time filter selection. The most successful design was the circular aperture pairs implemented on the aluminum foil. Segmentation was illustrated for simple and complex texture slides, glass template slides, and static and real-time FLIR imagery displayed on an LCTV.

  6. Optical metabolic imaging for monitoring tracheal health

    Science.gov (United States)

    Sharick, Joe T.; Gil, Daniel A.; Choma, Michael A.; Skala, Melissa C.

    2016-04-01

    The health of the tracheal mucosa and submucosa is a vital yet poorly understood component of critical care medicine, and a minimally-invasive method is needed to monitor tracheal health in patients. Of particular interest are the ciliated cells of the tracheal epithelium that move mucus away from the lungs and prevent respiratory infection. Optical metabolic imaging (OMI) allows cellular-level measurement of metabolism, and is a compelling method for assessing tracheal health because ciliary motor proteins require ATP to function. In this pilot study, we apply multiphoton imaging of the fluorescence intensities and lifetimes of metabolic co-enzymes NAD(P)H and FAD to the mucosa and submucosa of ex vivo mouse trachea. We demonstrate the feasibility and potential diagnostic utility of these measurements for assessing tracheal health and pathophysiology at the single-cell level.

  7. Optical imaging of neural and hemodynamic brain activity

    Science.gov (United States)

    Schei, Jennifer Lynn

    Optical imaging technologies can be used to record neural and hemodynamic activity. Neural activity elicits physiological changes that alter the optical tissue properties. Specifically, changes in polarized light are concomitant with neural depolarization. We measured polarization changes from an isolated lobster nerve during action potential propagation using both reflected and transmitted light. In transmission mode, polarization changes were largest throughout the center of the nerve, suggesting that most of the optical signal arose from the inner nerve bundle. In reflection mode, polarization changes were largest near the edges, suggesting that most of the optical signal arose from the outer sheath. To overcome irregular cell orientation found in the brain, we measured polarization changes from a nerve tied in a knot. Our results show that neural activation produces polarization changes that can be imaged even without regular cell orientations. Neural activation expends energy resources and elicits metabolic delivery through blood vessel dilation, increasing blood flow and volume. We used spectroscopic imaging techniques combined with electrophysiological measurements to record evoked neural and hemodynamic responses from the auditory cortex of the rat. By using implantable optics, we measured responses across natural wake and sleep states, as well as responses following different amounts of sleep deprivation. During quiet sleep, evoked metabolic responses were larger compared to wake, perhaps because blood vessels were more compliant. When animals were sleep deprived, evoked hemodynamic responses were smaller following longer periods of deprivation. These results suggest that prolonged neural activity through sleep deprivation may diminish vascular compliance as indicated by the blunted vascular response. Subsequent sleep may allow vessels to relax, restoring their ability to deliver blood. These results also suggest that severe sleep deprivation or chronic

  8. Absolute instruments and perfect imaging in geometrical optics

    CERN Document Server

    Tyc, Tomas; Sarbort, Martin; Bering, Klaus

    2011-01-01

    We investigate imaging by spherically symmetric absolute instruments that provide perfect imaging in the sense of geometrical optics. We derive a number of properties of such devices, present a general method for designing them and use this method to propose several new absolute instruments, in particular a lens providing a stigmatic image of an optically homogeneous region and having a moderate refractive index range.

  9. Super-resolution optical microscopy based on scannable cantilever-combined microsphere.

    Science.gov (United States)

    Wang, Shuying; Zhang, Dongxian; Zhang, Haijun; Han, Xu; Xu, Rui

    2015-12-01

    We report an ingenious method of super-resolution optical microscopy utilizing scannable cantilever-combined microsphere. By scanning the microsphere over the sample surface in a cantilever-combined microsphere-sample contact state, super-resolution images can be acquired at arbitrary sample regions through near-field information collection by the microsphere. In addition, such a state can effectively reduce the possibility of breaking the cantilever and damaging the microsphere or sample surface. This work has developed a new method and technique of sub-diffraction-limit optical microscopy, and can be practically applied in various fields of micro/nanoscopy.

  10. Processing of Graphene combining Optical Detection and Scanning Probe Lithography

    Directory of Open Access Journals (Sweden)

    Zimmermann Sören

    2015-01-01

    Full Text Available This paper presents an experimental setup tailored for robotic processing of graphene with in-situ vision based control. A robust graphene detection approach is presented applying multiple image processing operations of the visual feedback provided by a high-resolution light microscope. Detected graphene flakes can be modified using a scanning probe based lithographical process that is directly linked to the in-situ optical images. The results of this process are discussed with respect to further application scenarios.

  11. Active optical zoom for space-based imaging

    Science.gov (United States)

    Wick, David V.; Bagwell, Brett E.; Sweatt, William C.; Peterson, Gary L.; Martinez, Ty; Restaino, Sergio R.; Andrews, Jonathan R.; Wilcox, Christopher C.; Payne, Don M.; Romeo, Robert

    2006-08-01

    The development of sensors that are compact, lighter weight, and adaptive is critical for the success of future military initiatives. Space-based systems need the flexibility of a wide FOV for surveillance while simultaneously maintaining high-resolution for threat identification and tracking from a single, nonmechanical imaging system. In order to meet these stringent requirements, the military needs revolutionary alternatives to conventional imaging systems. We will present recent progress in active optical (aka nonmechanical) zoom for space applications. Active optical zoom uses multiple active optics elements to change the magnification of the imaging system. In order to optically vary the magnification of an imaging system, continuous mechanical zoom systems require multiple optical elements and use fine mechanical motion to precisely adjust the separations between individual or groups of elements. By incorporating active elements into the optical design, we have designed, demonstrated, and patented imaging systems that are capable of variable optical magnification with no macroscopic moving parts.

  12. Optical Tomography Imaging in Pneumatic Conveyor

    Directory of Open Access Journals (Sweden)

    Ruzairi Abdul Rahim

    2008-08-01

    Full Text Available This paper describes the development of a tomographic system by employing optical sensors using low cost approach. The final aim of this project is achieving real-time monitoring of solid particles having low concentration flow when conveyed in vertical pneumatic conveyor. The developed tomography system consists of 32 pairs of Light Emitting Diode (LED and silicon PIN photodiode. These sensors are used to monitor the emitted radiation for fluctuations caused by particles interfering with the beam when passing through it. A good design of sensor fixture may increase the collimating of light beam from a light source that passes through a flow regime. The obtained information from sensors provided the cross-sectional material distribution in conveyor. By using this information, the relationships between particle distribution and light attenuation effects are investigated by using computer programming to reconstruct the image. The results obtained from this investigation shows that the low cost optical sensors are suitable for monitoring low and medium concentration flowing materials. Optical sensors provide an opportunity to design sensors with a very wide bandwidth, thus enabling the measurement of high speed flowing particles or droplets.

  13. Picosecond optical MCPI-based imagers

    Science.gov (United States)

    Buckles, Robert A.; Guyton, Robert L.; Ross, Patrick W.

    2012-10-01

    We present the desired performance specifications for an advanced optical imager, which borrows practical concepts in high-speed microchannel plate (MCP) intensified x-ray stripline imagers and time-dilation techniques. With a four-fold speed improvement in state-of-the-art high-voltage impulse drivers, and novel atomic-layer deposition MCPs, we tender a design capable of 5 ps optical gating without the use of magnetic field confinement of the photoelectrons. We analyze the electron dispersion effects in the MCP and their implications for gating pulses shorter than the MCP transit time. We present a wideband design printed-circuit version of the Series Transmission Line Transformer (STLT) that makes use of 50-ohm coaxial 1.0 mm (110 GHz) and 1.85 mm (65 GHz) hermetically sealed vacuum feedthroughs and low-dispersion Teflon/Kapton circuit materials without the use of any vias. The STLT matches impedance at all interfaces with a 16:1 impedance (4:1 voltage) reduction, and delivers a dispersion-limited sharp impulse to the MCP strip. A comparison of microstrip design calculations is given, showing variances between method of moments, empirical codes, and finite element methods for broad, low-impedance traces. Prototype performance measurements are forthcoming.

  14. Extreme Adaptive Optics Planet Imager: XAOPI

    Energy Technology Data Exchange (ETDEWEB)

    Macintosh, B A; Graham, J; Poyneer, L; Sommargren, G; Wilhelmsen, J; Gavel, D; Jones, S; Kalas, P; Lloyd, J; Makidon, R; Olivier, S; Palmer, D; Patience, J; Perrin, M; Severson, S; Sheinis, A; Sivaramakrishnan, A; Troy, M; Wallace, K

    2003-09-17

    Ground based adaptive optics is a potentially powerful technique for direct imaging detection of extrasolar planets. Turbulence in the Earth's atmosphere imposes some fundamental limits, but the large size of ground-based telescopes compared to spacecraft can work to mitigate this. We are carrying out a design study for a dedicated ultra-high-contrast system, the eXtreme Adaptive Optics Planet Imager (XAOPI), which could be deployed on an 8-10m telescope in 2007. With a 4096-actuator MEMS deformable mirror it should achieve Strehl >0.9 in the near-IR. Using an innovative spatially filtered wavefront sensor, the system will be optimized to control scattered light over a large radius and suppress artifacts caused by static errors. We predict that it will achieve contrast levels of 10{sup 7}-10{sup 8} at angular separations of 0.2-0.8 inches around a large sample of stars (R<7-10), sufficient to detect Jupiter-like planets through their near-IR emission over a wide range of ages and masses. We are constructing a high-contrast AO testbed to verify key concepts of our system, and present preliminary results here, showing an RMS wavefront error of <1.3 nm with a flat mirror.

  15. Habitable Exoplanet Imager Optical Telescope Concept Design

    Science.gov (United States)

    Stahl, H Philip

    2017-01-01

    The Habitable Exoplanet Imaging Mission (HabEx) is one of four missions under study for the 2020 Astrophysics Decadal Survey. Its goal is to directly image and spectroscopically characterize planetary systems in the habitable zone of Sun-like stars. Additionally, HabEx will perform a broad range of general astrophysics science enabled by 100 to 2500 nm spectral range and 3 x 3 arc-minute FOV. Critical to achieving the HabEx science goals is a large, ultra-stable UV/Optical/Near-IR (UVOIR) telescope. The baseline HabEx telescope is a 4-meter off-axis unobscured three-mirror-anastigmatic, diffraction limited at 400 nm with wavefront stability on the order of a few 10s of picometers. This paper summarizes the opto-mechanical design of the HabEx baseline optical telescope assembly, including a discussion of how science requirements drive the telescope's specifications, and presents analysis that the baseline telescope structure meets its specified tolerances.

  16. Concurrent Application of TMS and Near-infrared Optical Imaging: Methodological Considerations and Potential Artifacts

    Directory of Open Access Journals (Sweden)

    Nathan A Parks

    2013-09-01

    Full Text Available The simultaneous application of transcranial magnetic stimulation (TMS with non-invasive neuroimaging provides a powerful method for investigating functional connectivity in the human brain and the causal relationships between areas in distributed brain networks. TMS has been combined with numerous neuroimaging techniques including, electroencephalography (EEG, functional magnetic resonance imaging (fMRI, and positron emission tomography (PET. Recent work has also demonstrated the feasibility and utility of combining TMS with non-invasive near-infrared optical imaging techniques, functional near-infrared spectroscopy (fNIRS and the event-related optical signal (EROS. Simultaneous TMS and optical imaging affords a number of advantages over other neuroimaging methods but also involves a unique set of methodological challenges and considerations. This paper describes the methodology of concurrently performing optical imaging during the administration of TMS, focusing on experimental design, potential artifacts, and approaches to controlling for these artifacts.

  17. Cascading Enhancement of Reflected Optical Third-Harmonic Imaging in Bio-Tissues

    Institute of Scientific and Technical Information of China (English)

    Yao; Duan-zheng; Xiong; Gui-guang

    2003-01-01

    A new nonlinear optical third-harmonic imaging technology in reflected fashion in bio-tissues by using cascading effect, a process whereby the second-order effects combine to contribute to a third-order nonlinear process, hs been analyzed. The performance of the reflected optical third harmonic imaging enhanced by cascading effect in bio-tissues is analyzed with the semi-classical theory. The microscopic understanding of the enhancement of cascaded optical third-harmonic imaging the reflected manner in bio-tissues has been discussed. Some ideas for further enhancement is given.

  18. Test for optical systems in laser projection imaging for PCB

    Science.gov (United States)

    Qin, Ouyang; Zhou, Jinyun; Lei, Liang; Lin, Qinghua

    2010-11-01

    Projection imaging is one of the most important steps in the fabrication of Printed Circuit Board. In order to meet the increasing demand for higher resolution, speed and larger area of imaging, a novel Laser Projection Imaging (LPI) has been developed to take the place of the conventional Hg lamp exposure. We set up a system with resolution 10μm over large exposure area of 460mm×610mm on substrate materials. The system is available by the combination of three main parts: an XeF excimer laser with a wavelength of 351nm and single pulse energy of 120mJ, an illumination system with numerical aperture (NA) value of 0.02, and a double telecentric optical projection lens with NA value of 0.025. Such designs can theoretically meet the demand of actual lithography. However, experiments have shown that the propagation loss ratio of laser power from the light source to the substrate can be up to 50% or more so as to hardly achieve the expected results. In this paper, we present our results of experiments under different conditions on laser projection imaging equipment, and meanwhile, parameters such as gas lifetime, pulse repetition rate, exposure dose, as well as the optical lose of quartz microlens array are analyzed. Finally, we acquired the optimum exposure parameters.

  19. Adaptive optics scanning laser ophthalmoscope imaging: technology update.

    Science.gov (United States)

    Merino, David; Loza-Alvarez, Pablo

    2016-01-01

    Adaptive optics (AO) retinal imaging has become very popular in the past few years, especially within the ophthalmic research community. Several different retinal techniques, such as fundus imaging cameras or optical coherence tomography systems, have been coupled with AO in order to produce impressive images showing individual cell mosaics over different layers of the in vivo human retina. The combination of AO with scanning laser ophthalmoscopy has been extensively used to generate impressive images of the human retina with unprecedented resolution, showing individual photoreceptor cells, retinal pigment epithelium cells, as well as microscopic capillary vessels, or the nerve fiber layer. Over the past few years, the technique has evolved to develop several different applications not only in the clinic but also in different animal models, thanks to technological developments in the field. These developments have specific applications to different fields of investigation, which are not limited to the study of retinal diseases but also to the understanding of the retinal function and vision science. This review is an attempt to summarize these developments in an understandable and brief manner in order to guide the reader into the possibilities that AO scanning laser ophthalmoscopy offers, as well as its limitations, which should be taken into account when planning on using it.

  20. Combining Different Modalities for 3D Imaging of Biological Objects

    CERN Document Server

    Tsyganov, E; Kulkarni, P; Mason, R; Parkey, R; Seliuonine, S; Shay, J; Soesbe, T; Zhezher, V; Zinchenko, A I

    2005-01-01

    A resolution enhanced NaI(Tl)-scintillator micro-SPECT device using pinhole collimator geometry has been built and tested with small animals. This device was constructed based on a depth-of-interaction measurement using a thick scintillator crystal and a position sensitive PMT to measure depth-dependent scintillator light profiles. Such a measurement eliminates the parallax error that degrades the high spatial resolution required for small animal imaging. This novel technique for 3D gamma-ray detection was incorporated into the micro-SPECT device and tested with a $^{57}$Co source and $^{98m}$Tc-MDP injected in mice body. To further enhance the investigating power of the tomographic imaging different imaging modalities can be combined. In particular, as proposed and shown in this paper, the optical imaging permits a 3D reconstruction of the animal's skin surface thus improving visualization and making possible depth-dependent corrections, necessary for bioluminescence 3D reconstruction in biological objects. ...

  1. Optical imaging with photonic hyper-crystals: Veselago lens and beyond

    Science.gov (United States)

    Huang, Zun; Narimanov, Evgenii E.

    2014-11-01

    We present an optical imaging system based on the recently introduced concept of photonic hyper-crystal, an artificial optical medium combining the properties of hyperbolic materials and photonic crystals. The proposed device functions as a Veselago lens with a nearly constant negative refractive index and substantially reduced image aberrations. The planar nature of this lens offers significant applications in nano-photolithography and hot-spots diagnosis in silicon-based semiconductor devices.

  2. An Integrated Optics beam combiner for the second generation VLTI instruments

    CERN Document Server

    Benisty, M; Jocou, L; Labeye, P; Malbet, F; Perraut, K; Kern, P

    2009-01-01

    The very recent years have seen a promising start in scientific publications making use of images produced by near-infrared long-baseline interferometry. The technique has reached, at last, a technical maturity level that opens new avenues for numerous astrophysical topics requiring milli-arcsecond model-independent imaging. The Very Large Telescope Interferometer (VLTI) is on the path to be equipped with instruments capable to combine between four to six telescopes. In the framework of the VLTI second generation instruments Gravity and VSI, we propose a new beam combining concept using Integrated Optics (IO) technologies with a novel ABCD-like fringe encoding scheme. Our goal is to demonstrate that IO-based combination brings considerable advantages in terms of instrumental design and performance. We therefore aim at giving a full characterization of an IO beam combiner to establish its performances and check its compliance with the specifications of an imaging instrument. Laboratory measurements were made i...

  3. Anterior Eye Imaging with Optical Coherence Tomography

    Science.gov (United States)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  4. Imaging of Stellar Surfaces with the Navy Precision Optical Interferometer

    Science.gov (United States)

    Jorgensen, A.; Schmitt, H. R.; van Belle, G. T.; Hutter, Clark; Mozurkewich, D.; Armstrong, J. T.; Baines, E. K.; Restaino, S. R.

    The Navy Precision Optical Interferometer (NPOI) has a unique layout which is particularly well-suited for high-resolution interferometric imaging. By combining the NPOI layout with a new data acquisition and fringe tracking system we are progressing toward a imaging capability which will exceed any other interferometer in operation. The project, funded by the National Science Foundation, combines several existing advances and infrastructure at NPOI with modest enhancements. For optimal imaging there are several requirements that should be fulfilled. The observatory should be capable of measuring visibilities on a wide range of baseline lengths and orientations, providing complete UV coverage in a short period of time. It should measure visibility amplitudes with good SNR on all baselines as critical imaging information is often contained in low-amplitude visibilities. It should measure the visibility phase on all baselines. The technologies which can achieve this are the NPOI Y-shaped array with (nearly) equal spacing between telescopes and an ability for rapid configuration. Placing 6-telescopes in a row makes it possible to measure visibilities into the 4th lobe of the visibility function. By arranging the available telescopes carefully we will be able to switch, every few days, between 3 different 6-station chains which provide symmetric coverage in the UV (Fourier) plane without moving any telescopes, only by moving beam relay mirrors. The 6-station chains are important to achieve the highest imaging resolution, and switching rapidly between station chains provides uniform coverage. Coherent integration techniques can be used to obtain good SNR on very small visibilities. Coherently integrated visibilities can be used for imaging with standard radio imaging packages such as AIPS. The commissioning of one additional station, the use of new data acquisition hardware and fringe tracking algorithms are the enhancements which make this project possible.

  5. CCD polarization imaging sensor with aluminum nanowire optical filters.

    Science.gov (United States)

    Gruev, Viktor; Perkins, Rob; York, Timothy

    2010-08-30

    We report an imaging sensor capable of recording the optical properties of partially polarized light by monolithically integrating aluminum nanowire optical filters with a CCD imaging array. The imaging sensor, composed of 1000 by 1000 imaging elements with 7.4 μm pixel pitch, is covered with an array of pixel-pitch matched nanowire optical filters with four different orientations offset by 45°. The polarization imaging sensor has a signal-to-noise ratio of 45 dB and captures intensity, angle and degree of linear polarization in the visible spectrum at 40 frames per second with 300 mW of power consumption.

  6. Reconstruction of Optical Thickness from Hoffman Modulation Contrast Images

    DEFF Research Database (Denmark)

    Olsen, Niels Holm; Sporring, Jon; Nielsen, Mads;

    2003-01-01

    Hoffman microscopy imaging systems are part of numerous fertility clinics world-wide. We discuss the physics of the Hoffman imaging system from optical thickness to image intensity, implement a simple, yet fast, reconstruction algorithm using Fast Fourier Transformation and discuss the usability...... of the method on a number of cells from a human embryo. Novelty is identifying the non-linearity of a typical Hoffman imaging system, and the application of Fourier Transformation to reconstruct the optical thickness....

  7. Can preoperative MR imaging predict optic nerve invasion of retinoblastoma?

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kyoung Doo, E-mail: kdsong0308@gmail.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Eo, Hong, E-mail: rtombow@gmail.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Kim, Ji Hye, E-mail: jhkate.kim@samsung.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Yoo, So-Young, E-mail: sy1131.yoo@samsung.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Jeon, Tae Yeon, E-mail: hathor97.jeon@samsung.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of)

    2012-12-15

    Purpose: To evaluate the accuracy of pre-operative MRI for the detection of optic nerve invasion in retinoblastoma. Materials and methods: Institutional review board approval and informed consent were waived for this retrospective study. A total of 41 patients were included. Inclusion criteria were histologically proven retinoblastoma, availability of diagnostic-quality preoperative MR images acquired during the 4 weeks before surgery, unilateral retinoblastoma, and normal-sized optic nerve. Two radiologists retrospectively reviewed the MR images independently. Five imaging findings (diffuse mild optic nerve enhancement, focal strong optic nerve enhancement, optic sheath enhancement, tumor location, and tumor size) were evaluated against optic nerve invasion of retinoblastoma. The predictive performance of all MR imaging findings for optic nerve invasion was also evaluated by the receiver operating characteristic curve analysis. Results: Optic nerve invasion was histopathologically confirmed in 24% of study population (10/41). The differences in diffuse mild enhancement, focal strong enhancement, optic sheath enhancement, and tumor location between patients with optic nerve invasion and patients without optic nerve invasion were not significant. Tumor sizes were 16.1 mm (SD: 2.2 mm) and 14.9 mm (SD: 3.6 mm) in patients with and without optic nerve involvement, respectively (P = 0.444). P-Values from binary logistic regression indicated that all five imaging findings were not significant predictors of tumor invasion of optic nerve. The AUC values of all MR imaging findings for the prediction of optic nerve invasion were 0.689 (95% confidence interval: 0.499–0.879) and 0.653 (95% confidence interval: 0.445–0.861) for observer 1 and observer 2, respectively. Conclusion: Findings of MRI in patients with normal-sized optic nerves have limited usefulness in preoperatively predicting the presence of optic nerve invasion in retinoblastoma.

  8. Advances in the Simultaneous Multiple Surface optical design method for imaging and non-imaging applications

    OpenAIRE

    Wang, Lin

    2012-01-01

    Classical imaging optics has been developed over centuries in many areas, such as its paraxial imaging theory and practical design methods like multi-parametric optimization techniques. Although these imaging optical design methods can provide elegant solutions to many traditional optical problems, there are more and more new design problems, like solar concentrator, illumination system, ultra-compact camera, etc., that require maximum energy transfer efficiency, or ultra-compact optical stru...

  9. Optimized optical clearing method for imaging central nervous system

    Science.gov (United States)

    Yu, Tingting; Qi, Yisong; Gong, Hui; Luo, Qingming; Zhu, Dan

    2015-03-01

    The development of various optical clearing methods provides a great potential for imaging entire central nervous system by combining with multiple-labelling and microscopic imaging techniques. These methods had made certain clearing contributions with respective weaknesses, including tissue deformation, fluorescence quenching, execution complexity and antibody penetration limitation that makes immunostaining of tissue blocks difficult. The passive clarity technique (PACT) bypasses those problems and clears the samples with simple implementation, excellent transparency with fine fluorescence retention, but the passive tissue clearing method needs too long time. In this study, we not only accelerate the clearing speed of brain blocks but also preserve GFP fluorescence well by screening an optimal clearing temperature. The selection of proper temperature will make PACT more applicable, which evidently broaden the application range of this method.

  10. Modeling plasmonic scattering combined with thin-film optics.

    Science.gov (United States)

    Schmid, M; Klenk, R; Lux-Steiner, M Ch; Topic, M; Krc, J

    2011-01-14

    Plasmonic scattering from metal nanostructures presents a promising concept for improving the conversion efficiency of solar cells. The determination of optimal nanostructures and their position within the solar cell is crucial to boost the efficiency. Therefore we established a one-dimensional optical model combining plasmonic scattering and thin-film optics to simulate optical properties of thin-film solar cells including metal nanoparticles. Scattering models based on dipole oscillations and Mie theory are presented and their integration in thin-film semi-coherent optical descriptions is explained. A plasmonic layer is introduced in the thin-film structure to simulate scattering properties as well as parasitic absorption in the metal nanoparticles. A proof of modeling concept is given for the case of metal-island grown silver nanoparticles on glass and ZnO:Al/glass substrates. Using simulations a promising application of the nanoparticle integration is shown for the case of CuGaSe(2) solar cells.

  11. Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging.

    Science.gov (United States)

    Zawadzki, Robert J; Jones, Steven M; Pilli, Suman; Balderas-Mata, Sandra; Kim, Dae Yu; Olivier, Scot S; Werner, John S

    2011-06-01

    We describe an ultrahigh-resolution (UHR) retinal imaging system that combines adaptive optics Fourier-domain optical coherence tomography (AO-OCT) with an adaptive optics scanning laser ophthalmoscope (AO-SLO) to allow simultaneous data acquisition by the two modalities. The AO-SLO subsystem was integrated into the previously described AO-UHR OCT instrument with minimal changes to the latter. This was done in order to ensure optimal performance and image quality of the AO- UHR OCT. In this design both imaging modalities share most of the optical components including a common AO-subsystem and vertical scanner. One of the benefits of combining Fd-OCT with SLO includes automatic co-registration between two acquisition channels for direct comparison between retinal structures imaged by both modalities (e.g., photoreceptor mosaics or microvasculature maps). Because of differences in the detection scheme of the two systems, this dual imaging modality instrument can provide insight into retinal morphology and potentially function, that could not be accessed easily by a single system. In this paper we describe details of the components and parameters of the combined instrument, including incorporation of a novel membrane magnetic deformable mirror with increased stroke and actuator count used as a single wavefront corrector. We also discuss laser safety calculations for this multimodal system. Finally, retinal images acquired in vivo with this system are presented.

  12. Novel spirometry based on optical surface imaging

    Energy Technology Data Exchange (ETDEWEB)

    Li, Guang, E-mail: lig2@mskcc.org; Huang, Hailiang; Li, Diana G.; Chen, Qing; Gaebler, Carl P.; Mechalakos, James [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Wei, Jie [Department of Computer Science, City College of New York, New York, New York 10031 (United States); Sullivan, James [Pulmonary Laboratories, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Zatcky, Joan; Rimner, Andreas [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States)

    2015-04-15

    Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume

  13. Clinical optical coherence tomography combined with multiphoton tomography for evaluation of several skin disorders

    Science.gov (United States)

    König, Karsten; Speicher, Marco; Bückle, Rainer; Reckfort, Julia; McKenzie, Gordon; Welzel, Julia; Koehler, Martin J.; Elsner, Peter; Kaatz, Martin

    2010-02-01

    The first clinical trial of optical coherence tomography (OCT) combined with multiphoton tomography (MPT) and dermoscopy is reported. State-of-the-art (i) OCT systems for dermatology (e.g. multibeam swept source OCT), (ii) the femtosecond laser multiphoton tomograph DermaInspectTM, and (iii) digital dermoscopes were applied to 47 patients with a diversity of skin diseases and disorders such as skin cancer, psoriasis, hemangioma, connective tissue diseases, pigmented lesions, and autoimmune bullous skin diseases. Dermoscopy, also called 'epiluminescent microscopy', provides two-dimensional color images of the skin surface. OCT imaging is based on the detection of optical reflections within the tissue measured interferometrically whereas nonlinear excitation of endogenous fluorophores and the second harmonic generation are the bases of MPT images. OCT cross sectional "wide field" image provides a typical field of view of 5 x 2 mm2 and offers fast information on the depth and the volume of the investigated lesion. In comparison, multiphoton tomography presents 0.36 x 0.36 mm2 horizontal or diagonal sections of the region of interest within seconds with submicron resolution and down to a tissue depth of 200 μm. The combination of OCT and MPT provides a synergistic optical imaging modality for early detection of skin cancer and other skin diseases.

  14. Dynamic optical aberration correction with adaptive coded apertures techniques in conformal imaging

    Science.gov (United States)

    Li, Yan; Hu, Bin; Zhang, Pengbin; Zhang, Binglong

    2015-02-01

    Conformal imaging systems are confronted with dynamic aberration in optical design processing. In classical optical designs, for combination high requirements of field of view, optical speed, environmental adaption and imaging quality, further enhancements can be achieved only by the introduction of increased complexity of aberration corrector. In recent years of computational imaging, the adaptive coded apertures techniques which has several potential advantages over more traditional optical systems is particularly suitable for military infrared imaging systems. The merits of this new concept include low mass, volume and moments of inertia, potentially lower costs, graceful failure modes, steerable fields of regard with no macroscopic moving parts. Example application for conformal imaging system design where the elements of a set of binary coded aperture masks are applied are optimization designed is presented in this paper, simulation results show that the optical performance is closely related to the mask design and the reconstruction algorithm optimization. As a dynamic aberration corrector, a binary-amplitude mask located at the aperture stop is optimized to mitigate dynamic optical aberrations when the field of regard changes and allow sufficient information to be recorded by the detector for the recovery of a sharp image using digital image restoration in conformal optical system.

  15. Multimode optical imaging of small animals: development and applications

    Science.gov (United States)

    Hwang, J. Y.; Moffatt-Blue, C.; Equils, O.; Fujita, M.; Jeong, J.; Khazenzon, N. M.; Lindsley, E.; Ljubimova, J.; Nowatzyk, A. G.; Farkas, D. L.; Wachsmann-Hogiu, S.

    2007-02-01

    We present an optical system for small animal imaging that can combine various in vivo imaging modalities, including fluorescence (intensity and lifetime), spectral, and trans-illumination imaging. This system consists of light-tight box with ultrafast pulsed or cw laser light excitation, motorized translational and rotational stages, a telecentric lens for detection, and a cooled CCD camera that can be coupled to an ultrafast time-gated intensifier. All components are modular, making possible laser excitation at various wavelengths and pulse lengths, and signal detection in a variety of ways (multimode). Results of drug nanoconjugate carrier delivery studies in mice are presented. Conventional and spectrally-resolved fluorescence images reveal details of in vivo drug nanoconjugate carrier accumulation within the tumor region and several organs in real time. By multi-spectral image analysis of ex vivo specimens from the same mice, we were able to evaluate the extent and topology of drug nanoconjugate carrier distribution into specific organs and the tumor itself.

  16. Investigation on Fine Registration for SAR and Optical Image

    Directory of Open Access Journals (Sweden)

    You Hong-jian

    2014-02-01

    Full Text Available The registration of SAR and optical remote sensing image is the basise for fusing of multi-source image and comprehensive analysis. In this paper a new fine registration method for SAR and optical image is proposed. Firstly, three to four corresponding points are selected manually to realize a coarse registration that eliminates the differences in scale and rotation. Many characteristic points in the optical image are detected and the corresponding points in SAR image are extracted using normalized gradient correlations based on the different gradients by operators. An irregular triangle network is constructed using these corresponding points and each triangle region is finely registered. Finally SAR image and optical image are finely registered. Experiment and processed results demonstrate the feasibility of this method.

  17. Optical coherence tomography image denoising using Gaussianization transform

    Science.gov (United States)

    Amini, Zahra; Rabbani, Hossein

    2017-08-01

    We demonstrate the power of the Gaussianization transform (GT) for modeling image content by applying GT for optical coherence tomography (OCT) denoising. The proposed method is a developed version of the spatially constrained Gaussian mixture model (SC-GMM) method, which assumes that each cluster of similar patches in an image has a Gaussian distribution. SC-GMM tries to find some clusters of similar patches in the image using a spatially constrained patch clustering and then denoise each cluster by the Wiener filter. Although in this method GMM distribution is assumed for the noisy image, holding this assumption on a dataset is not investigated. We illustrate that making a Gaussian assumption on a noisy dataset has a significant effect on denoising results. For this purpose, a suitable distribution for OCT images is first obtained and then GT is employed to map this original distribution of OCT images to a GMM distribution. Then, this Gaussianized image is used as the input of the SC-GMM algorithm. This method, which is a combination of GT and SC-GMM, remarkably improves the results of OCT denoising compared with earlier version of SC-GMM and even produces better visual and numerical results than the state-of-the art works in this field. Indeed, the main advantage of the proposed OCT despeckling method is texture preservation, which is important for main image processing tasks like OCT inter- and intraretinal layer analysis. Thus, to prove the efficacy of the proposed method for this analysis, an improvement in the segmentation of intraretinal layers using the proposed method as a preprocessing step is investigated. Furthermore, the proposed method can achieve the best expert ranking between other contending methods, and the results show the helpfulness and usefulness of the proposed method in clinical applications.

  18. Document Indexing for Image-Based Optical Information Systems.

    Science.gov (United States)

    Thiel, Thomas J.; And Others

    1991-01-01

    Discussion of image-based information retrieval systems focuses on indexing. Highlights include computerized information retrieval; multimedia optical systems; optical mass storage and personal computers; and a case study that describes an optical disk system which was developed to preserve, access, and disseminate military documents. (19…

  19. Novel optical scanning cryptography using Fresnel telescope imaging.

    Science.gov (United States)

    Yan, Aimin; Sun, Jianfeng; Hu, Zhijuan; Zhang, Jingtao; Liu, Liren

    2015-07-13

    We propose a new method called modified optical scanning cryptography using Fresnel telescope imaging technique for encryption and decryption of remote objects. An image or object can be optically encrypted on the fly by Fresnel telescope scanning system together with an encryption key. For image decryption, the encrypted signals are received and processed with an optical coherent heterodyne detection system. The proposed method has strong performance through use of secure Fresnel telescope scanning with orthogonal polarized beams and efficient all-optical information processing. The validity of the proposed method is demonstrated by numerical simulations and experimental results.

  20. Optical Treatment of Strabismic and Combined Strabismic-Anisometropic Amblyopia

    Science.gov (United States)

    2011-01-01

    Objective To determine visual acuity improvement in children with strabismic and combined strabismic-anisometropic (combined-mechanism) amblyopia treated with optical correction alone and to explore factors associated with improvement. Design Prospective multi-center cohort study Participants 146 children 3 to amblyopia (N=52) or combined-mechanism amblyopia (N=94). Methods Optical treatment was provided as spectacles (prescription based on a cycloplegic refraction) that were worn for the first time at the baseline visit. Visual acuity with spectacles was measured using the Amblyopia Treatment Study HOTV© visual acuity protocol at baseline and every 9 weeks thereafter until no further improvement in visual acuity. Ocular alignment was assessed at each visit. Main outcome measure Visual acuity 18 weeks after baseline. Results Overall, amblyopic eye visual acuity improved a mean of 2.6 lines (95% confidence interval: 2.3 to 3.0), with 75% of children improving ≥2 lines and 54% improving ≥3 lines. Resolution of amblyopia occurred in 32% (95% confidence interval: 24% to 41%) of the children. The treatment effect was greater for strabismic amblyopia than for combined-mechanism amblyopia (3.2 versus 2.3 lines, adjusted P=0.003). Visual acuity improved regardless of whether eye alignment improved. Conclusions Optical treatment alone of strabismic and combined-mechanism amblyopia results in clinically meaningful improvement in amblyopic eye visual acuity for most 3 to amblyopia before initiating other therapies. PMID:21959371

  1. Changing image of correlation optics: introduction

    DEFF Research Database (Denmark)

    Angelsky, Oleg V.; Desyatnikov, Anton S.; Gbur, Gregory J.;

    2016-01-01

    This feature issue of Applied Optics contains a series of selected papers reflecting recent progress of correlation optics and illustrating current trends in vector singular optics, internal energy flows at light fields, optical science of materials, and new biomedical applications of lasers. (C)...

  2. Changing image of correlation optics: introduction.

    Science.gov (United States)

    Angelsky, Oleg V; Desyatnikov, Anton S; Gbur, Gregory J; Hanson, Steen G; Lee, Tim; Miyamoto, Yoko; Schneckenburger, Herbert; Wyant, James C

    2016-04-20

    This feature issue of Applied Optics contains a series of selected papers reflecting recent progress of correlation optics and illustrating current trends in vector singular optics, internal energy flows at light fields, optical science of materials, and new biomedical applications of lasers.

  3. Changing image of correlation optics: introduction

    DEFF Research Database (Denmark)

    Angelsky, Oleg V.; Desyatnikov, Anton S.; Gbur, Gregory J.

    2016-01-01

    This feature issue of Applied Optics contains a series of selected papers reflecting recent progress of correlation optics and illustrating current trends in vector singular optics, internal energy flows at light fields, optical science of materials, and new biomedical applications of lasers. (C...

  4. Metal artifact reduction based on the combined prior image

    CERN Document Server

    Zhang, Yanbo

    2014-01-01

    Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to find a good prior image is the key of this class methods, and numerous algorithms have been proposed to address this issue recently. In this work, by using image mutual correlation, pixels in the original reconstructed image or linear interpolation corrected image, which are less affected by artifacts, are selected to build a combined image. Thereafter, a better prior image is generated from the combined image by using tissue classification. The results of three patients' CT images show that the proposed method can reduce metal artifacts remarkably.

  5. Imaging combined autoimmune and infectious disease microarrays

    Science.gov (United States)

    Ewart, Tom; Raha, Sandeep; Kus, Dorothy; Tarnopolsky, Mark

    2006-09-01

    Bacterial and viral pathogens are implicated in many severe autoimmune diseases, acting through such mechanisms as molecular mimicry, and superantigen activation of T-cells. For example, Helicobacter pylori, well known cause of stomach ulcers and cancers, is also identified in ischaemic heart disease (mimicry of heat shock protein 65), autoimmune pancreatitis, systemic sclerosis, autoimmune thyroiditis (HLA DRB1*0301 allele susceptibility), and Crohn's disease. Successful antibiotic eradication of H.pylori often accompanies their remission. Yet current diagnostic devices, and test-limiting cost containment, impede recognition of the linkage, delaying both diagnosis and therapeutic intervention until the chronic debilitating stage. We designed a 15 minute low cost 39 antigen microarray assay, combining autoimmune, viral and bacterial antigens1. This enables point-of-care serodiagnosis and cost-effective narrowly targeted concurrent antibiotic and monoclonal anti-T-cell and anti-cytokine immunotherapy. Arrays of 26 pathogen and 13 autoimmune antigens with IgG and IgM dilution series were printed in triplicate on epoxysilane covalent binding slides with Teflon well masks. Sera diluted 1:20 were incubated 10 minutes, washed off, anti-IgG-Cy3 (green) and anti-IgM-Dy647 (red) were incubated for 5 minutes, washed off and the slide was read in an ArrayWoRx(e) scanning CCD imager (Applied Precision, Issaquah, WA). As a preliminary model for the combined infectious disease-autoimmune diagnostic microarray we surveyed 98 unidentified, outdated sera that were discarded after Hepatitis B antibody testing. In these, significant IgG or IgM autoantibody levels were found: dsDNA 5, ssDNA 11, Ro 2, RNP 7, SSB 4, gliadin 2, thyroglobulin 13 cases. Since control sera showed no autoantibodies, the high frequency of anti-DNA and anti-thyroglobulin antibodies found in infected sera lend increased support for linkage of infection to subsequent autoimmune disease. Expansion of the antigen

  6. Correlative super-resolution fluorescence microscopy combined with optical coherence microscopy

    Science.gov (United States)

    Kim, Sungho; Kim, Gyeong Tae; Jang, Soohyun; Shim, Sang-Hee; Bae, Sung Chul

    2015-03-01

    Recent development of super-resolution fluorescence imaging technique such as stochastic optical reconstruction microscopy (STORM) and photoactived localization microscope (PALM) has brought us beyond the diffraction limits. It allows numerous opportunities in biology because vast amount of formerly obscured molecular structures, due to lack of spatial resolution, now can be directly observed. A drawback of fluorescence imaging, however, is that it lacks complete structural information. For this reason, we have developed a super-resolution multimodal imaging system based on STORM and full-field optical coherence microscopy (FF-OCM). FF-OCM is a type of interferometry systems based on a broadband light source and a bulk Michelson interferometer, which provides label-free and non-invasive visualization of biological samples. The integration between the two systems is simple because both systems use a wide-field illumination scheme and a conventional microscope. This combined imaging system gives us both functional information at a molecular level (~20nm) and structural information at the sub-cellular level (~1μm). For thick samples such as tissue slices, while FF-OCM is readily capable of imaging the 3D architecture, STORM suffer from aberrations and high background fluorescence that substantially degrade the resolution. In order to correct the aberrations in thick tissues, we employed an adaptive optics system in the detection path of the STORM microscope. We used our multimodal system to obtain images on brain tissue samples with structural and functional information.

  7. Nonlinear optical microscopy for imaging thin films and surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Smilowitz, L.B.; McBranch, D.W.; Robinson, J.M.

    1995-03-01

    We have used the inherent surface sensitivity of second harmonic generation to develop an instrument for nonlinear optical microscopy of surfaces and interfaces. We have demonstrated the use of several nonlinear optical responses for imaging thin films. The second harmonic response of a thin film of C{sub 60} has been used to image patterned films. Two photon absorption light induced fluorescence has been used to image patterned thin films of Rhodamine 6G. Applications of nonlinear optical microscopy include the imaging of charge injection and photoinduced charge transfer between layers in semiconductor heterojunction devices as well as across membranes in biological systems.

  8. Handbook of 3D machine vision optical metrology and imaging

    CERN Document Server

    Zhang, Song

    2013-01-01

    With the ongoing release of 3D movies and the emergence of 3D TVs, 3D imaging technologies have penetrated our daily lives. Yet choosing from the numerous 3D vision methods available can be frustrating for scientists and engineers, especially without a comprehensive resource to consult. Filling this gap, Handbook of 3D Machine Vision: Optical Metrology and Imaging gives an extensive, in-depth look at the most popular 3D imaging techniques. It focuses on noninvasive, noncontact optical methods (optical metrology and imaging). The handbook begins with the well-studied method of stereo vision and

  9. Translational research of optical molecular imaging for personalized medicine.

    Science.gov (United States)

    Qin, C; Ma, X; Tian, J

    2013-12-01

    In the medical imaging field, molecular imaging is a rapidly developing discipline and forms many imaging modalities, providing us effective tools to visualize, characterize, and measure molecular and cellular mechanisms in complex biological processes of living organisms, which can deepen our understanding of biology and accelerate preclinical research including cancer study and medicine discovery. Among many molecular imaging modalities, although the penetration depth of optical imaging and the approved optical probes used for clinics are limited, it has evolved considerably and has seen spectacular advances in basic biomedical research and new drug development. With the completion of human genome sequencing and the emergence of personalized medicine, the specific drug should be matched to not only the right disease but also to the right person, and optical molecular imaging should serve as a strong adjunct to develop personalized medicine by finding the optimal drug based on an individual's proteome and genome. In this process, the computational methodology and imaging system as well as the biomedical application regarding optical molecular imaging will play a crucial role. This review will focus on recent typical translational studies of optical molecular imaging for personalized medicine followed by a concise introduction. Finally, the current challenges and the future development of optical molecular imaging are given according to the understanding of the authors, and the review is then concluded.

  10. Improvement of tissue analysis and classification using optical coherence tomography combined with Raman spectroscopy

    Science.gov (United States)

    Liu, Chih-Hao; Qi, Ji; Lu, Jing; Wang, Shang; Wu, Chen; Shih, Wei-Chuan; Larin, Kirill V.

    2014-02-01

    Optical coherence tomography (OCT) is an optical imaging technique that is capable of performing high-resolution (approaching the histopathology level) and real-time imaging of tissues without use of contrast agents. Based on these advantages, the pathological features of tumors (in micro scale) can be identified during resection surgery. However, the accuracy of tumor margin prediction still needs to be enhanced for assisting the judgment of surgeons. In this regard, we present a two-dimensional computational method for advanced tissue analysis and characterization based on optical coherence tomography (OCT) and Raman spectroscopy (RS). The method combines the slope of OCT intensity signal and the Principal component (PC) of RS, and relies on the tissue optical attenuation and chemical ingredients for the classification of tissue types. Our pilot experiments were performed on mouse kidney, liver and small intestine. Results demonstrate the improvement of the tissue differentiation compared with the analysis only based on the OCT detection. This combined OCT/RS method is potentially useful as a novel optical biopsy technique for cancer detection.

  11. Implementation Of A Prototype Digital Optical Cellular Image Processor (DOCIP)

    Science.gov (United States)

    Huang, K. S.; Sawchuk, A. A.; Jenkins, B. K.; Chavel, P.; Wang, J. M.; Weber, A. G.; Wang, C. H.; Glaser, I.

    1989-02-01

    A processing element of a prototype digital optical cellular image processor (DOCIP) is implemented to demonstrate a particular parallel computing and interconnection architecture. This experimental digital optical computing system consists of a 2-D array of 54 optical logic gates, a 2-D array of 53 subholograms to provide interconnections between gates, and electronic input/output interfaces. The multi-facet interconnection hologram used in this system is fabricated by a computer-controlled optical system to offer very flexible interconnections.

  12. Clinical optical coherence tomography combined with multiphoton tomography of patients with skin diseases.

    Science.gov (United States)

    König, Karsten; Speicher, Marco; Bückle, Rainer; Reckfort, Julia; McKenzie, Gordon; Welzel, Julia; Koehler, Martin J; Elsner, Peter; Kaatz, Martin

    2009-07-01

    We report on the first clinical study based on optical coherence tomography (OCT) in combination with multiphoton tomography (MPT) and dermoscopy. 47 patients with a variety of skin diseases and disorders such as skin cancer, psoriasis, hemangioma, connective tissue diseases, pigmented lesions, and autoimmune bullous skin diseases have been investigated with (i) state-of-the-art OCT systems for dermatology including multibeam swept source OCT, (ii) the femtosecond laser multiphoton tomograph, and (iii) dermoscopes. Dermoscopy provides two-dimensional color images of the skin surface. OCT images reflect modifications of the intratissue refractive index whereas MPT is based on nonlinear excitation of endogenous fluorophores and second harmonic generation. A stack of cross-sectional OCT "wide field" images with a typical field of view of 5 x 2 mm(2) gave fast information on the depth and the volume of the lesion. Multiphoton tomography provided 0.36 x 0.36 mm(2) horizontal/diagonal optical sections within seconds of a particular region of interest with superior submicron resolution down to a tissue depth of 200 mum. The combination of OCT and MPT provides a unique powerful optical imaging modality for early detection of skin cancer and other skin diseases as well as for the evaluation of the efficiency of treatments.

  13. Molecular probes for nonlinear optical imaging of biological membranes

    Science.gov (United States)

    Blanchard-Desce, Mireille H.; Ventelon, Lionel; Charier, Sandrine; Moreaux, Laurent; Mertz, Jerome

    2001-12-01

    Second-harmonic generation (SHG) and two-photon excited fluorescence (TPEF) are nonlinear optical (NLO) phenomena that scale with excitation intensity squared, and hence give rise to an intrinsic 3-dimensional resolution when used in microscopic imaging. TPEF microscopy has gained widespread popularity in the biology community whereas SHG microscopy promises to be a powerful tool because of its sensitivity to local asymmetry. We have implemented an approach toward the design of NLO-probes specifically adapted for SHG and/or TPEF imaging of biological membranes. Our strategy is based on the design of nanoscale amphiphilic NLO-phores. We have prepared symmetrical bolaamphiphilic fluorophores combining very high two-photon absorption (TPA) cross-sections in the visible red region and affinity for cellular membranes. Their incorporation and orientation in lipid membranes can be monitored via TPEF anisotropy. We have also prepared amphiphilic push-pull chromophores exhibiting both large TPA cross-sections and very large first hyperpolarizabilities in the near-IR region. These NLO-probes have proved to be particularly useful for imaging of biological membranes by simultaneous SHG and TPEF microscopy and offer attractive prospects for real-time imaging of fundamental biological processes such as adhesion, fusion or reporting of membrane potentials.

  14. SPECIAL ASPECTS OF INITIAL OPTICAL SCHEME SELECTION FOR DESIGN OF NON-IMAGING OPTICAL SYSTEMS

    Directory of Open Access Journals (Sweden)

    R. V. Anitropov

    2016-01-01

    Full Text Available Subject of Research. The research results, structural composition analysis and the parametric synthesis of the projected imaging and non-imaging optical systems were presented. We made an attempt to use the gained experience about imaging systems while designing non-imaging systems, by adapting the composition theory for the calculations of non-imaging systems. Several patterns were revealed, which provide a deeper understanding of the design process of non-imaging optical systems; measures of its optimization were proposed. Method. We investigated the applicability of the theory of composition and synthesis of non-imaging optical systems. The main provisions of the theory of composition are based on the division of all available optical elements in four types depending on their functionality, which corresponds to a modular design. Similar items were identified in non-imaging optical systems and adaptation of composition theory to their design became possible. Main Results. General design patterns of imaging and non-imaging optical systems were studied. Classification of systems, components, as well as technical and generic characteristics of imaging and non-imaging optical systems was determined. Search mechanism of the initial optical system by means of structural and parametric synthesis of non-imaging optical system was formalized. The basic elements were determined included in non-imaging systems and their classification by functionality was done. They were subdivided into basic, corrective, wide angle and high aperture ones. The rules for formation of these elements and their composition were determined: surface reflecting, refracting, spherical and nonspherical elements with total internal reflection. The foundations of composition theory for non-imaging optical systems were laid. The approbation of this method was carried out on the example of the illumination system calculation for surgical room. A 3D model of an illumination optical

  15. Computational high-resolution optical imaging of the living human retina

    Science.gov (United States)

    Shemonski, Nathan D.; South, Fredrick A.; Liu, Yuan-Zhi; Adie, Steven G.; Scott Carney, P.; Boppart, Stephen A.

    2015-07-01

    High-resolution in vivo imaging is of great importance for the fields of biology and medicine. The introduction of hardware-based adaptive optics (HAO) has pushed the limits of optical imaging, enabling high-resolution near diffraction-limited imaging of previously unresolvable structures. In ophthalmology, when combined with optical coherence tomography, HAO has enabled a detailed three-dimensional visualization of photoreceptor distributions and individual nerve fibre bundles in the living human retina. However, the introduction of HAO hardware and supporting software adds considerable complexity and cost to an imaging system, limiting the number of researchers and medical professionals who could benefit from the technology. Here we demonstrate a fully automated computational approach that enables high-resolution in vivo ophthalmic imaging without the need for HAO. The results demonstrate that computational methods in coherent microscopy are applicable in highly dynamic living systems.

  16. Single-shot optical imaging through scattering medium using digital in-line holography

    CERN Document Server

    R., Vinu; Somkuwar, Atul S; Park, YongKeun; Singh, Rakesh Kumar

    2016-01-01

    Non-invasive and single-shot holographic imaging through complex media is technically challenging due to random light scattering which significantly scrambles optical information. Recently, several methods have been presented to address this issue. However, they require complicated measurements of optical transmission matrices, or existing techniques do only retrieve intensity information. Here we propose and experimentally demonstrate a holographic approach for single-shot imaging through a scattering layer based on digital in-line holography in combination with the autocorrelation of the speckle intensity. Using a simple optical configuration and experimental procedure, the proposed method enables to retrieve the complex amplitude image of an object located at arbitrary planes behind scattering media. The technique has potential applications in biomedical imaging, deep tissue microscopy, and 3D imaging through turbid media.

  17. Hybrid micro-/nanogels for optical sensing and intracellular imaging

    Directory of Open Access Journals (Sweden)

    Shuiqin Zhou

    2010-12-01

    Full Text Available Hybrid micro-/nanogels are playing an increasing important part in a diverse range of applications, due to their tunable dimensions, large surface area, stable interior network structure, and a very short response time. We review recent advances and challenges in the developments of hybrid micro-/nanogels toward applications for optical sensing of pH, temperature, glucose, ions, and other species as well as for intracellular imaging. Due to their unique advantages, hybrid micro-/nanogels as optical probes are attracting substantial interests for continuous monitoring of chemical parameters in complex samples such as blood and bioreactor fluids, in chemical research and industry, and in food quality control. In particular, their intracellular probing ability enables the monitoring of the biochemistry and biophysics of live cells over time and space, thus contributing to the explanation of intricate biological processes and the development of novel diagnoses. Unlike most other probes, hybrid micro-/nanogels could also combine other multiple functions into a single probe. The rational design of hybrid micro-/nanogels will not only improve the probing applications as desirable, but also implement their applications in new arenas. With ongoing rapid advances in bionanotechnology, the well-designed hybrid micro-/nanogel probes will be able to provide simultaneous sensing, imaging diagnosis, and therapy toward clinical applications.

  18. A simple multipurpose double-beam optical image analyzer

    CERN Document Server

    Popowicz, Adam

    2016-01-01

    In the paper we present a low cost optical device which splits the light in the focal plane into two separate optical paths and collimates it back into a single image plane, and where a selective information processing ca be carried out. The optical system is straightforward and easy implementable as it consists of only three lens and two mirrors. The system is dedicated for imaging in low-light-level conditions in which widely used optical devices, based on beam-splitters or dichroic mirrors, suffer from light loss. We expose examples of applications of our device, using a prototype model. The proposed optical system may be employed for: monitoring the objects located in different distances from observer (1), creating regions of different magnification within a single image plane (2), high dynamic range photometry (3), or imaging in two wavelength bands simultaneously (4).

  19. A simple multipurpose double-beam optical image analyzer

    Science.gov (United States)

    Popowicz, A.; Blachowicz, T.

    2016-07-01

    In the paper we present a low cost optical device which splits the light in the focal plane into two separate optical paths and collimates it back into a single image plane, and where a selective information processing can be carried out. The optical system is straightforward and easily implementable as it consists of only three lenses and two mirrors. The system is dedicated for imaging in low-light-level conditions in which widely used optical devices, based on beam splitters or dichroic mirrors, suffer from light loss. We expose examples of applications of our device, using a prototype model. The proposed optical system may be employed for: monitoring the objects located at different distances from observer (1), creating regions of different magnification within a single image plane (2), high dynamic range photometry (3), or imaging in two wavelength bands simultaneously (4).

  20. Optical microscopic imaging based on VRML language

    Science.gov (United States)

    Zhang, Xuedian; Zhang, Zhenyi; Sun, Jun

    2009-11-01

    As so-called VRML (Virtual Reality Modeling Language), is a kind of language used to establish a model of the real world or a colorful world made by people. As in international standard, VRML is the main kind of program language based on the "www" net building, which is defined by ISO, the kind of MIME is x-world or x-VRML. The most important is that it has no relationship with the operating system. Otherwise, because of the birth of VRML 2.0, its ability of describing the dynamic condition gets better, and the interaction of the internet evolved too. The use of VRML will bring a revolutionary change of confocal microscope. For example, we could send different kinds of swatch in virtual 3D style to the net. On the other hand, scientists in different countries could use the same microscope in the same time to watch the same samples by the internet. The mode of sending original data in the model of text has many advantages, such as: the faster transporting, the fewer data, the more convenient updating and fewer errors. In the following words we shall discuss the basic elements of using VRML in the field of Optical Microscopic imaging.

  1. New approach to optical imaging of tumors

    Science.gov (United States)

    Achilefu, Samuel I.; Bugaj, Joseph E.; Dorshow, Richard B.; Jimenez, Hermo N.; Rajagopalan, Raghavan

    2001-07-01

    Site specific delivery of drugs and contrast agents to tumors protects normal tissues from the cytotoxic effect of drugs, and enhances the contrast between normal and diseased tissues. In optical medicine, biocompatible dyes can be used as phototherapeutics or as contrast agents. Previous studies have shown that the use of covalent or non-covalent dye conjugates of carriers such as antibiodies, liposomes, and polysaccharides improves the delivery of such molecules to tumors. However, large biomolecules can elicit adverse immunogenic reactions and also result in long blood clearance times, delaying visualization of target tissues. A viable alternative to this strategy is to use small bioactive molecule-dye conjugates. These molecules have several advantages over large biomolecules, including ease of synthesis of a variety of high purity compounds for combinatorial screening of new targets, enhanced diffusivity to solid tumors, and the ability to affect the pharmacokinetics of the conjugates by minor structural changes. Thus, we conjugated a near infrared absorbing dye to several bioactive peptides that specifically target overexpressed tumor receptors in established rat tumor lines. High tumor uptake of the conjugates was obtained without loss of either the peptide receptor affinity or the dye fluorescence. These findings demonstrate the efficacy of a small peptide-dye conjugate strategy for in vivo tumor imaging. Site-specific delivery of photodynamic therapy agents may also benefit from this approach.

  2. Joint Applied Optics and Chinese Optics Letters feature introduction: digital holography and three-dimensional imaging.

    Science.gov (United States)

    Poon, Ting-Chung

    2011-12-01

    This feature issue serves as a pilot issue promoting the joint issue of Applied Optics and Chinese Optics Letters. It focuses upon topics of current relevance to the community working in the area of digital holography and 3-D imaging. © 2011 Optical Society of America

  3. Joint Applied Optics and Chinese Optics Letters feature introduction: digital holography and three-dimensional imaging

    OpenAIRE

    Poon, Ting-Chung

    2011-01-01

    This feature issue serves as a pilot issue promoting the joint issue of Applied Optics and Chinese Optics Letters. It focuses upon topics of current relevance to the community working in the area of digital holography and 3-D imaging. (C) 2011 Optical Society of America

  4. Ultrahigh resolution optical coherence elastography combined with a rigid micro-endoscope (Conference Presentation)

    Science.gov (United States)

    Fang, Qi; Curatolo, Andrea; Wijesinghe, Philip; Hamzah, Juliana; Ganss, Ruth; Noble, Peter B.; Karnowski, Karol; Sampson, David D.; Kim, Jun Ki; Lee, Wei M.; Kennedy, Brendan F.

    2017-02-01

    The mechanical forces that living cells experience represent an important framework in the determination of a range of intricate cellular functions and processes. Current insight into cell mechanics is typically provided by in vitro measurement systems; for example, atomic force microscopy (AFM) measurements are performed on cells in culture or, at best, on freshly excised tissue. Optical techniques, such as Brillouin microscopy and optical elastography, have been used for ex vivo and in situ imaging, recently achieving cellular-scale resolution. The utility of these techniques in cell mechanics lies in quick, three-dimensional and label-free mechanical imaging. Translation of these techniques toward minimally invasive in vivo imaging would provide unprecedented capabilities in tissue characterization. Here, we take the first steps along this path by incorporating a gradient-index micro-endoscope into an ultrahigh resolution optical elastography system. Using this endoscope, a lateral resolution of 2 µm is preserved over an extended depth-of-field of 80 µm, achieved by Bessel beam illumination. We demonstrate this combined system by imaging stiffness of a silicone phantom containing stiff inclusions and a freshly excised murine liver tissue. Additionally, we test this system on murine ribs in situ. We show that our approach can provide high quality extended depth-of-field images through an endoscope and has the potential to measure cell mechanics deep in tissue. Eventually, we believe this tool will be capable of studying biological processes and disease progression in vivo.

  5. Three dimensional reconstruction of conventional stereo optic disc image.

    Science.gov (United States)

    Kong, H J; Kim, S K; Seo, J M; Park, K H; Chung, H; Park, K S; Kim, H C

    2004-01-01

    Stereo disc photograph was analyzed and reconstructed as 3 dimensional contour image to evaluate the status of the optic nerve head for the early detection of glaucoma and the evaluation of the efficacy of treatment. Stepwise preprocessing was introduced to detect the edge of the optic nerve head and retinal vessels and reduce noises. Paired images were registered by power cepstrum method and zero-mean normalized cross-correlation. After Gaussian blurring, median filter application and disparity pair searching, depth information in the 3 dimensionally reconstructed image was calculated by the simple triangulation formula. Calculated depth maps were smoothed through cubic B-spline interpolation and retinal vessels were visualized more clearly by adding reference image. Resulted 3 dimensional contour image showed optic cups, retinal vessels and the notching of the neural rim of the optic disc clearly and intuitively, helping physicians in understanding and interpreting the stereo disc photograph.

  6. MR imaging findings in subacute combined degeneration of the spinal cord: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Jun; Lee, Jae Hee; Lee, Sung Yong; Chung, Sung Woo [Our Lady of Mercy Hospital, The Catholic University of Korea, Incheon (Korea, Republic of)

    2000-09-01

    Vitamin B12 deficiency can cause neurologic complications in the spinal cord, brain, and optic and peripheral nerves. Subacute combined degeneration is a rare disease of demyelinating lesions of the spinal cord, affecting mainly the posterior and lateral columns of the thoracic cord. We report the MR imaging findings of a case of subacute combined degeneration of the spinal cord in a patient with vitamin B12 deficiency and mega loblastic anemia. (author)

  7. Living Brain Optical Imaging: Technology, Methods and Applications

    Science.gov (United States)

    Tsytsarev, Vassiliy; Bernardelli, Chad; Maslov, Konstantin I.

    2017-01-01

    Within the last few decades, optical imaging methods have yielded revolutionary results when applied to all parts of the central nervous system. The purpose of this review is to analyze research possibilities and limitations of several novel imaging techniques and show some of the most interesting achievements obtained by these methods. Here we covered intrinsic optical imaging, voltage-sensitive dye, photoacoustic, optical coherence tomography, near-infrared spectroscopy and some other techniques. All of them are mainly applicable for experimental neuroscience but some of them also suitable for the clinical studies.

  8. Image Retrieval Using a Combination of Keywords and Image Features

    OpenAIRE

    Reddy, Vishwanath Reddy Keshi; Bandikolla, Praveen

    2008-01-01

    Information retrieval systems are playing an important role in our day to day life for getting the required information. Many text retrieval systems are available and are working successfully. Even though internet is full of other media like images, audio and video, retrieval systems for these media are rare and have not achieved success as that of text retrieval systems. Image retrieval systems are useful in many applications; there is a high demand for effective and efficient tool for image...

  9. Refractory optic perineuritis due to granulomatosis with polyangiitis successfully treated with methotrexate and mycophenolate mofetil combination therapy

    Science.gov (United States)

    Kimura, Yoshitaka; Asako, Kurumi; Kikuchi, Hirotoshi; Kono, Hajime

    2017-01-01

    Optic perineuritis is an uncommon inflammatory disorder of the optic sheath that causes visual loss or eye pain. There are few case reports of optic perineuritis associated with granulomatosis with polyangiitis. Herein we report the case of a 37-year-old male with granulomatosis with polyangiitis and who presented with headache, blurred vision in the right eye, diplopia, and numbness in the right forehead. Brain magnetic resonance images (MRI) findings revealed hypertrophic pachymeningitis and refractory optic perineuritis. These were manageable only by means of weekly methotrexate and mycophenolate mofetil combination therapy but not with methotrexate, mycophenolate mofetil, intravenous cyclophosphamide, rituximab, azathioprine, or cyclosporine individually. PMID:28293459

  10. Magnetic resonance imaging of luxury perfusion of the optic nerve head in anterior ischemic optic neuropathy.

    Science.gov (United States)

    Yovel, Oren S; Katz, Miriam; Leiba, Hana

    2012-09-01

    A 49-year-old woman with painless reduction in visual acuity in her left eye was found to have nonarteritic anterior ischemic optic neuropathy (NAION). Fluorescein angiography revealed optic disc capillary leakage consistent with "luxury perfusion." Contrast-enhanced FLAIR magnetic resonance imaging (MRI) showed marked enhancement of the left optic disc. Resolution of the optic disc edema and the MRI abnormalities followed a similar time course. This report appears unique in documenting the MRI findings of luxury perfusion in NAION.

  11. Optical coherence tomography angiography offers comprehensive evaluation of skin optical clearing in vivo by quantifying optical properties and blood flow imaging simultaneously

    Science.gov (United States)

    Guo, Li; Shi, Rui; Zhang, Chao; Zhu, Dan; Ding, Zhihua; Li, Peng

    2016-08-01

    Tissue optical clearing (TOC) is helpful for reducing scattering and enhancing the penetration depth of light, and shows promising potential in optimizing optical imaging performances. A mixture of fructose with PEG-400 and thiazone (FPT) is used as an optical clearing agent in mouse dorsal skin and evaluated with OCT angiography (Angio-OCT) by quantifying optical properties and blood flow imaging simultaneously. It is observed that FPT leads to an improved imaging performance for the deeper tissues. The imaging performance improvement is most likely caused by the FPT-induced dehydration of skin, and the reduction of scattering coefficient (more than ˜40.5%) and refractive-index mismatching (more than ˜25.3%) in the superficial (epidermal, dermal, and hypodermal) layers. A high correlation (up to ˜90%) between the relative changes in refractive-index mismatching and Angio-OCT signal strength is measured. The optical clearing rate is ˜5.83×10-5 cm/s. In addition, Angio-OCT demonstrates enhanced performance in imaging cutaneous hemodynamics with satisfactory spatiotemporal resolution and contrast when combined with TOC, which exhibits a powerful practical application in studying microcirculation.

  12. Optical molecular imaging for detection of Barrett's-associated neoplasia

    Institute of Scientific and Technical Information of China (English)

    Nadhi Thekkek; Sharmila Anandasabapathy; Rebecca Richards-Kortum

    2011-01-01

    Recent advancements in the endoscopic imaging of Barrett's esophagus can be used to probe a wide range of optical properties that are altered with neoplastic progression.This review summarizes relevant changes in optical properties as well as imaging approaches that measures those changes.Wide-field imaging approaches include narrow-band imaging that measures changes in light scattering and absorption,and autofluorescence imaging that measure changes in endogenous fluorophores.High-resolution imaging approaches include optical coherence tomography,endocytoscopy,confocal microendoscopy,and high-resolution microendoscopy.These technologies,some coupled with an appropriate contrast agent,can measure differences in glandular morphology,nuclear morphology,or vascular alterations associated with neoplasia.Advances in targeted contrast agents are further discussed.Studies that have explored these technologies are highlighted;as are the advantages and limitations of each.

  13. Optical color-image encryption and synthesis using coherent diffractive imaging in the Fresnel domain.

    Science.gov (United States)

    Chen, Wen; Chen, Xudong; Sheppard, Colin J R

    2012-02-13

    We propose a new method using coherent diffractive imaging for optical color-image encryption and synthesis in the Fresnel domain. An optical multiple-random-phase-mask encryption system is applied, and a strategy based on lateral translations of a phase-only mask is employed during image encryption. For the decryption, an iterative phase retrieval algorithm is applied to extract high-quality decrypted color images from diffraction intensity maps (i.e., ciphertexts). In addition, optical color-image synthesis is also investigated based on coherent diffractive imaging. Numerical results are presented to demonstrate feasibility and effectiveness of the proposed method. Compared with conventional interference methods, coherent diffractive imaging approach may open up a new research perspective or can provide an effective alternative for optical color-image encryption and synthesis.

  14. In vivo tumor detection with combined MR–Photoacoustic-Thermoacoustic imaging

    Directory of Open Access Journals (Sweden)

    Lin Huang

    2016-09-01

    Full Text Available Here, we report a new method using combined magnetic resonance (MR–Photoacoustic (PA–Thermoacoustic (TA imaging techniques, and demonstrate its unique ability for in vivo cancer detection using tumor-bearing mice. Circular scanning TA and PA imaging systems were used to recover the dielectric and optical property distributions of three colon carcinoma bearing mice While a 7.0-T magnetic resonance imaging (MRI unit with a mouse body volume coil was utilized for high resolution structural imaging of the same mice. Three plastic tubes filled with soybean sauce were used as fiducial markers for the co-registration of MR, PA and TA images. The resulting fused images provided both enhanced tumor margin and contrast relative to the surrounding normal tissues. In particular, some finger-like protrusions extending into the surrounding tissues were revealed in the MR/TA infused images. These results show that the tissue functional optical and dielectric properties provided by PA and TA images along with the anatomical structure by MRI in one picture make accurate tumor identification easier. This combined MR–PA–TA-imaging strategy has the potential to offer a clinically useful triple-modality tool for accurate cancer detection and for intraoperative surgical navigation.

  15. Polarization sensitive spectroscopic optical coherence tomography for multimodal imaging

    Science.gov (United States)

    Strąkowski, Marcin R.; Kraszewski, Maciej; Strąkowska, Paulina; Trojanowski, Michał

    2015-03-01

    Optical coherence tomography (OCT) is a non-invasive method for 3D and cross-sectional imaging of biological and non-biological objects. The OCT measurements are provided in non-contact and absolutely safe way for the tested sample. Nowadays, the OCT is widely applied in medical diagnosis especially in ophthalmology, as well as dermatology, oncology and many more. Despite of great progress in OCT measurements there are still a vast number of issues like tissue recognition or imaging contrast enhancement that have not been solved yet. Here we are going to present the polarization sensitive spectroscopic OCT system (PS-SOCT). The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. Unlike standard polarization sensitive OCT the PS-SOCT delivers spectral information about measured quantities e.g. tested object birefringence changes over the light spectra. This solution overcomes the limits of polarization sensitive analysis applied in standard PS-OCT. Based on spectral data obtained from PS-SOCT the exact value of birefringence can be calculated even for the objects that provide higher order of retardation. In this contribution the benefits of using the combination of time-frequency and polarization sensitive analysis are being expressed. Moreover, the PS-SOCT system features, as well as OCT measurement examples are presented.

  16. An adaptive optics imaging system designed for clinical use.

    Science.gov (United States)

    Zhang, Jie; Yang, Qiang; Saito, Kenichi; Nozato, Koji; Williams, David R; Rossi, Ethan A

    2015-06-01

    Here we demonstrate a new imaging system that addresses several major problems limiting the clinical utility of conventional adaptive optics scanning light ophthalmoscopy (AOSLO), including its small field of view (FOV), reliance on patient fixation for targeting imaging, and substantial post-processing time. We previously showed an efficient image based eye tracking method for real-time optical stabilization and image registration in AOSLO. However, in patients with poor fixation, eye motion causes the FOV to drift substantially, causing this approach to fail. We solve that problem here by tracking eye motion at multiple spatial scales simultaneously by optically and electronically integrating a wide FOV SLO (WFSLO) with an AOSLO. This multi-scale approach, implemented with fast tip/tilt mirrors, has a large stabilization range of ± 5.6°. Our method consists of three stages implemented in parallel: 1) coarse optical stabilization driven by a WFSLO image, 2) fine optical stabilization driven by an AOSLO image, and 3) sub-pixel digital registration of the AOSLO image. We evaluated system performance in normal eyes and diseased eyes with poor fixation. Residual image motion with incremental compensation after each stage was: 1) ~2-3 arc minutes, (arcmin) 2) ~0.5-0.8 arcmin and, 3) ~0.05-0.07 arcmin, for normal eyes. Performance in eyes with poor fixation was: 1) ~3-5 arcmin, 2) ~0.7-1.1 arcmin and 3) ~0.07-0.14 arcmin. We demonstrate that this system is capable of reducing image motion by a factor of ~400, on average. This new optical design provides additional benefits for clinical imaging, including a steering subsystem for AOSLO that can be guided by the WFSLO to target specific regions of interest such as retinal pathology and real-time averaging of registered images to eliminate image post-processing.

  17. Mitigation Approaches for Optical Imaging through Clouds and Fog

    Science.gov (United States)

    2009-11-01

    communications, remote sensing, and imaging. The advantages of performing imaging in the optical band are manifold. Modern Lidar and Ladar systems are preferred...image, the area search rate is low for this approach. This method is widely used in LIDAR applications in clear weather conditions. One intermediate...the average. This can be done by forcing the expectation of the Froebenius norm of H to 1. The resulting receiving image at the photodetectors can be

  18. Progresses in 3D integral imaging with optical processing

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Corral, Manuel; Martinez-Cuenca, Raul; Saavedra, Genaro; Navarro, Hector; Pons, Amparo [Department of Optics. University of Valencia. Calle Doctor Moliner 50, E46 100, Burjassot (Spain); Javidi, Bahram [Electrical and Computer Engineering Department, University of Connecticut, Storrs, CT 06269-1157 (United States)], E-mail: manuel.martinez@uv.es

    2008-11-01

    Integral imaging is a promising technique for the acquisition and auto-stereoscopic display of 3D scenes with full parallax and without the need of any additional devices like special glasses. First suggested by Lippmann in the beginning of the 20th century, integral imaging is based in the intersection of ray cones emitted by a collection of 2D elemental images which store the 3D information of the scene. This paper is devoted to the study, from the ray optics point of view, of the optical effects and interaction with the observer of integral imaging systems.

  19. Sub-diffraction-Limit Imaging in Optical Hyperlens

    Institute of Scientific and Technical Information of China (English)

    HU Ji-Gang; WANG Pei; LU Yong-Hua; MING Hai; CHEN Chun-Chong; CHEN Jun-Xue

    2008-01-01

    @@ Sub-diffraction-limit imaging in the optical hyperlens based on cylindrical metamaterials is studied. Some param-eters of hyperlens, such as the dispersive relation and the divergence angle of imaging, are numerically analysed with the ray trajectory method and effective medium theory. The dependence of imaging properties on dielectric constant is discussed. As a result, a 0° divergence angle is obtained for the best imaging effect. This work will be helpful for the design, structure fabrication and resolution improvement of the optical hyperlens.

  20. Electro-Optic Imaging Fourier Transform Spectral Polarimeter Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Boulder Nonlinear Systems, Inc. (BNS) proposes to develop an Electro-Optic Imaging Fourier Transform Spectral Polarimeter (E-O IFTSP). The polarimetric system is...

  1. Single Molecule Imaging in Living Cell with Optical Method

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Significance, difficult, international developing actuality and our completed works for single molecules imaging in living cell with optical method are described respectively. Additionally we give out some suggestions for the technology development further.

  2. Adaptive optics technology for high-resolution retinal imaging.

    Science.gov (United States)

    Lombardo, Marco; Serrao, Sebastiano; Devaney, Nicholas; Parravano, Mariacristina; Lombardo, Giuseppe

    2012-12-27

    Adaptive optics (AO) is a technology used to improve the performance of optical systems by reducing the effects of optical aberrations. The direct visualization of the photoreceptor cells, capillaries and nerve fiber bundles represents the major benefit of adding AO to retinal imaging. Adaptive optics is opening a new frontier for clinical research in ophthalmology, providing new information on the early pathological changes of the retinal microstructures in various retinal diseases. We have reviewed AO technology for retinal imaging, providing information on the core components of an AO retinal camera. The most commonly used wavefront sensing and correcting elements are discussed. Furthermore, we discuss current applications of AO imaging to a population of healthy adults and to the most frequent causes of blindness, including diabetic retinopathy, age-related macular degeneration and glaucoma. We conclude our work with a discussion on future clinical prospects for AO retinal imaging.

  3. Adaptive Optics Technology for High-Resolution Retinal Imaging

    Directory of Open Access Journals (Sweden)

    Giuseppe Lombardo

    2012-12-01

    Full Text Available Adaptive optics (AO is a technology used to improve the performance of optical systems by reducing the effects of optical aberrations. The direct visualization of the photoreceptor cells, capillaries and nerve fiber bundles represents the major benefit of adding AO to retinal imaging. Adaptive optics is opening a new frontier for clinical research in ophthalmology, providing new information on the early pathological changes of the retinal microstructures in various retinal diseases. We have reviewed AO technology for retinal imaging, providing information on the core components of an AO retinal camera. The most commonly used wavefront sensing and correcting elements are discussed. Furthermore, we discuss current applications of AO imaging to a population of healthy adults and to the most frequent causes of blindness, including diabetic retinopathy, age-related macular degeneration and glaucoma. We conclude our work with a discussion on future clinical prospects for AO retinal imaging.

  4. A combined method for correlative 3D imaging of biological samples from macro to nano scale

    Science.gov (United States)

    Kellner, Manuela; Heidrich, Marko; Lorbeer, Raoul-Amadeus; Antonopoulos, Georgios C.; Knudsen, Lars; Wrede, Christoph; Izykowski, Nicole; Grothausmann, Roman; Jonigk, Danny; Ochs, Matthias; Ripken, Tammo; Kühnel, Mark P.; Meyer, Heiko

    2016-10-01

    Correlative analysis requires examination of a specimen from macro to nano scale as well as applicability of analytical methods ranging from morphological to molecular. Accomplishing this with one and the same sample is laborious at best, due to deformation and biodegradation during measurements or intermediary preparation steps. Furthermore, data alignment using differing imaging techniques turns out to be a complex task, which considerably complicates the interconnection of results. We present correlative imaging of the accessory rat lung lobe by combining a modified Scanning Laser Optical Tomography (SLOT) setup with a specially developed sample preparation method (CRISTAL). CRISTAL is a resin-based embedding method that optically clears the specimen while allowing sectioning and preventing degradation. We applied and correlated SLOT with Multi Photon Microscopy, histological and immunofluorescence analysis as well as Transmission Electron Microscopy, all in the same sample. Thus, combining CRISTAL with SLOT enables the correlative utilization of a vast variety of imaging techniques.

  5. Imaging osteoarthritis in the knee joints using x-ray guided diffuse optical tomography

    Science.gov (United States)

    Zhang, Qizhi; Yuan, Zhen; Sobel, Eric S.; Jiang, Huabei

    2010-02-01

    In our previous studies, near-infrared (NIR) diffuse optical tomography (DOT) had been successfully applied to imaging osteoarthritis (OA) in the finger joints where significant difference in optical properties of the joint tissues was evident between healthy and OA finger joints. Here we report for the first time that large joints such as the knee can also be optically imaged especially when DOT is combined with x-ray tomosynthesis where the 3D image of the bones from x-ray is incorporated into the DOT reconstruction as spatial a priori structural information. This study demonstrates that NIR light can image large joints such as the knee in addition to finger joints, which will drastically broaden the clinical utility of our x-ray guided DOT technique for OA diagnosis.

  6. Coded access optical sensor (CAOS) imager and applications

    Science.gov (United States)

    Riza, Nabeel A.

    2016-04-01

    Starting in 2001, we proposed and extensively demonstrated (using a DMD: Digital Micromirror Device) an agile pixel Spatial Light Modulator (SLM)-based optical imager based on single pixel photo-detection (also called a single pixel camera) that is suited for operations with both coherent and incoherent light across broad spectral bands. This imager design operates with the agile pixels programmed in a limited SNR operations starring time-multiplexed mode where acquisition of image irradiance (i.e., intensity) data is done one agile pixel at a time across the SLM plane where the incident image radiation is present. Motivated by modern day advances in RF wireless, optical wired communications and electronic signal processing technologies and using our prior-art SLM-based optical imager design, described using a surprisingly simple approach is a new imager design called Coded Access Optical Sensor (CAOS) that has the ability to alleviate some of the key prior imager fundamental limitations. The agile pixel in the CAOS imager can operate in different time-frequency coding modes like Frequency Division Multiple Access (FDMA), Code-Division Multiple Access (CDMA), and Time Division Multiple Access (TDMA). Data from a first CAOS camera demonstration is described along with novel designs of CAOS-based optical instruments for various applications.

  7. Imaging of acoustic fields using optical feedback interferometry.

    Science.gov (United States)

    Bertling, Karl; Perchoux, Julien; Taimre, Thomas; Malkin, Robert; Robert, Daniel; Rakić, Aleksandar D; Bosch, Thierry

    2014-12-01

    This study introduces optical feedback interferometry as a simple and effective technique for the two-dimensional visualisation of acoustic fields. We present imaging results for several pressure distributions including those for progressive waves, standing waves, as well as the diffraction and interference patterns of the acoustic waves. The proposed solution has the distinct advantage of extreme optical simplicity and robustness thus opening the way to a low cost acoustic field imaging system based on mass produced laser diodes.

  8. Optical image encryption based on a joint Fresnel transform correlator with double optical wedges.

    Science.gov (United States)

    Shen, Xueju; Dou, Shuaifeng; Lei, Ming; Chen, Yudan

    2016-10-20

    An optical cryptosystem based on the joint Fresnel transform correlator (JFTC) with double optical wedges is designed. The designed cryptosystem retains the two major advantages of JTC-based optical cryptosystems. First, the encrypted image is real-valued and therefore is easier to record and transmit. Second, the encryption process is simplified, since it doesn't require accurate alignment of optical elements or the generation of the complex conjugate of the key. Also, the designed optical cryptosystem can produce a decrypted image with higher quality than a JTC-based optical cryptosystem, because the original encrypted image is divided by the Fresnel transform power distribution of the key mask to generate the new encrypted image, which significantly reduces the noise during the decryption process. Simulation results showed that the correlation coefficient of the decrypted image and the original image can reach as large as 0.9819 after denoising and adequately selecting half-central interval a and encrypted image width w. Another improvement relative to JTC-based optical cryptosystems is that the attack resistibility gets enhanced due to the nonlinearity of the encryption process as well as the additional key parameter a, which enlarges the key space.

  9. Peptide-Based Optical uPAR Imaging for Surgery

    DEFF Research Database (Denmark)

    Juhl, Karina; Christensen, Anders; Persson, Morten;

    2016-01-01

    Near infrared intra-operative optical imaging is an emerging technique with clear implications for improved cancer surgery by enabling a more distinct delineation of the tumor margins during resection. This modality has the potential to increase the number of patients having a curative radical......-operative optical guidance in cancer surgery to ensure complete removal of tumors while preserving adjacent, healthy tissue....

  10. Direct optical imaging of structural inhomogeneities in crystalline materials.

    Science.gov (United States)

    Grigorev, A M

    2016-05-10

    A method for optical imaging of structural inhomogeneities in crystalline materials is proposed, based on the differences in the optical properties of the structural inhomogeneity and the homogeneous material near the fundamental absorption edge of the crystalline material. The method can be used to detect defects in both semiconductors and insulators.

  11. Imaging rat esophagus using combination of reflectance confocal and multiphoton microscopy

    Science.gov (United States)

    Zhuo, S. M.; Chen, J. X.; Jiang, X. S.; Lu, K. C.; Xie, S. S.

    2008-08-01

    We combine reflectance confocal microscopy (RCM) with multiphoton microscopy (MPM) to image rat esophagus. The two imaging modalities allow detection of layered-resolved complementary information from esophagus. In the keratinizing layer, the keratinocytes boundaries can be characterized by RCM, while the keratinocytes cytoplasm (keratin) can be further imaged by multiphoton autofluorescence signal. In the epithelium, the epithelial cellular boundaries and nucleus can be detected by RCM, and MPM can be used for imaging epithelial cell cytoplasm and monitoring metabolic state of epithelium. In the stroma, multiphoton autofluorescence signal is used to image elastin and second harmonic generation signal is utilized to detect collagen, while RCM is used to determine the optical property of stroma. Overall, these results suggest that the combination of RCM and MPM has potential to provide more important and comprehensive information for early diagnosis of esophageal cancer.

  12. Combining interior and exterior characteristics for remote sensing image denoising

    Science.gov (United States)

    Peng, Ni; Sun, Shujin; Wang, Runsheng; Zhong, Ping

    2016-04-01

    Remote sensing image denoising faces many challenges since a remote sensing image usually covers a wide area and thus contains complex contents. Using the patch-based statistical characteristics is a flexible method to improve the denoising performance. There are usually two kinds of statistical characteristics available: interior and exterior characteristics. Different statistical characteristics have their own strengths to restore specific image contents. Combining different statistical characteristics to use their strengths together may have the potential to improve denoising results. This work proposes a method combining statistical characteristics to adaptively select statistical characteristics for different image contents. The proposed approach is implemented through a new characteristics selection criterion learned over training data. Moreover, with the proposed combination method, this work develops a denoising algorithm for remote sensing images. Experimental results show that our method can make full use of the advantages of interior and exterior characteristics for different image contents and thus improve the denoising performance.

  13. Twin image elimination in digital holography by combination of Fourier transformations

    CERN Document Server

    Choudhury, Debesh

    2013-01-01

    We present a new technique for removing twin image in in-line digital Fourier holography using a combination of Fourier transformations. Instead of recording only a Fourier transform hologram of the object, we propose to record a combined Fourier transform hologram by simultaneously recording the hologram of the Fourier transform and the inverse Fourier transform of the object with suitable weighting coefficients. Twin image is eliminated by appropriate inverse combined Fourier transformation and proper choice of the weighting coefficients. An optical configuration is presented for recording combined Fourier transform holograms. Simulations demonstrate the feasibility of twin image elimination. The hologram reconstruction is sensitive to phase aberrations of the object, thereby opening a way for holographic phase sensing.

  14. Graphene-Based Optical Biosensors and Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Zhiwen; He, Shijiang; Pei, Hao; Du, Dan; Fan, Chunhai; Lin, Yuehe

    2014-01-13

    This chapter focuses on the design, fabrication and application of graphene based optical nanobiosensors. The emerging graphene based optical nanobiosensors demonstrated the promising bioassay and biomedical applications thanking to the unique optical features of graphene. According to the different applications, the graphene can be tailored to form either fluorescent emitter or efficient fluorescence quencher. The exceptional electronic feature of graphene makes it a powerful platform for fabricating the SPR and SERS biosensors. Today the graphene based optical biosensors have been constructed to detect various targets including ions, small biomolecules, DNA/RNA and proteins. This chapter reviews the recent progress in graphene-based optical biosensors and discusses the opportunities and challenges in this field.

  15. Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems.

    Science.gov (United States)

    Downie, J D; Goodman, J W

    1989-10-15

    A ground-based adaptive optics imaging telescope system attempts to improve image quality by measuring and correcting for atmospherically induced wavefront aberrations. The necessary control computations during each cycle will take a finite amount of time, which adds to the residual error variance since the atmosphere continues to change during that time. Thus an optical processor may be well-suited for this task. This paper investigates this possibility by studying the accuracy requirements in a general optical processor that will make it competitive with, or superior to, a conventional digital computer for adaptive optics use.

  16. Magneto-optical color imaging of magnetic field distribution

    Directory of Open Access Journals (Sweden)

    Yosuke Nagakubo

    2017-05-01

    Full Text Available The magneto-optical (MO imaging technique allows magnetic field distributions to be observed in real-time. In this paper, we demonstrate a MO color imaging technique that allows quantitative values of magnetic fields to be determined by the naked eye. MO color imaging is realized using a MO imaging plate, which contains a bismuth-substituted iron garnet film. The imaging plate was prepared by the metal organic decomposition method, and a light source consisting of green and yellow light-emitting diodes or a white light-emitting diode. MO color imaging of the magnetic field distribution of a commercial ferrite magnet is demonstrated.

  17. [Effects of aerosol optical thickness on the optical remote sensing imaging quality].

    Science.gov (United States)

    Hu, Xin-Li; Gu, Xing-Fa; Yu, Tao; Zhang, Zhou-Wei; Li, Juan; Luan, Hai-Jun

    2014-03-01

    In recent years, due to changes in atmospheric environment, atmospheric aerosol affection on optical sensor imaging quality is increasingly considered by the load developed departments. Space-based remote sensing system imaging process, atmospheric aerosol makes optical sensor imaging quality deterioration. Atmospheric medium causing image degradation is mainly forward light scattering effect caused by the aerosol turbid medium. Based on the turbid medium radiation transfer equation, the point spread function models were derived contained aerosol optical properties of atmosphere in order to analyze and evaluate the atmospheric blurring effect on optical sensor imaging system. It was found that atmospheric aerosol medium have effect on not only energy decay of atmospheric transmittance, but also the degradation of image quality due to the scattering effect. Increase of atmospheric aerosol optical thickness makes aerosol scattering intensity enhanced, variation of aerosol optical thickness is also strongly influences the point spread function of the spatial distribution. it is because the degradation of aerosol in spatial domain, which reduces the quality of remote sensing image, in particularly reduction of the sharpness of image. Meanwhile, it would provide a method to optimize and improve simulation of atmospheric chain.

  18. Ghost imaging protocol for magneto-optical applications

    CERN Document Server

    Meda, A; Avella, A; Berchera, I Ruo; Degiovanni, I P; Magni, A; Genovese, M

    2015-01-01

    We develop a new approach in magneto-optical imaging (MOI), applying for the first time a ghost imaging (GI) protocol to perform Faraday microscopy. MOI is one of the most exploited technique for the study of magnetic properties of a material, through Weiss domains form, distribution and dimension analysis. Nevertheless, a lack of imaging of domains in some extreme conditions as cryogenic temperatures or high magnetic fields application is present due to the difficulties related to the imaging setup construction limitation. Here we present a technique that separates the imaging optical path to the one illuminating the object. The technique is based on thermal light GI and exploits correlations between light beams. GI is applied to the Faraday magneto-optical observation of magnetic domains of an Yttrium Iron Garnet (YIG) sample.

  19. Sagittal laser optical tomography for imaging of rheumatoid finger joints

    Energy Technology Data Exchange (ETDEWEB)

    Hielscher, Andreas H [Departments of Biomedical Engineering and Radiology, Columbia University, New York, NY 10027 (United States); Klose, Alexander D [Departments of Biomedical Engineering and Radiology, Columbia University, New York, NY 10027 (United States); Scheel, Alexander K [Department of Nephrology and Rheumatology, Georg-August University, Goettingen (Germany); Moa-Anderson, Bryte [Departments of Biomedical Engineering and Radiology, Columbia University, New York, NY 10027 (United States); Backhaus, Marina [Department of Rheumatology and Clinical Immunology, Charite University Hospital, Berlin (Germany); Netz, Uwe [Institute for Medical Physics and Laser Medicine, Free University of Berlin, Berlin (Germany); Beuthan, Juergen [Institute for Medical Physics and Laser Medicine, Free University of Berlin, Berlin (Germany)

    2004-04-07

    We present a novel optical tomographic imaging system that was designed to determine two-dimensional spatial distribution of optical properties in a sagittal plane through finger joints. The system incorporates a single laser diode and a single silicon photodetector into a scanning device that records spatially resolved light intensities as they are transmitted through a finger. These data are input to a model-based iterative image reconstruction (MOBIIR) scheme, which uses the equation of radiative transfer (ERT) as a forward model for light propagation through tissue. We have used this system to obtain tomographic images of six proximal interphalangeal finger joints from two patients with rheumatoid arthritis. The optical images were compared to clinical symptoms and ultrasound images.

  20. Ultrafast optical imaging technology: principles and applications of emerging methods

    Science.gov (United States)

    Mikami, Hideharu; Gao, Liang; Goda, Keisuke

    2016-09-01

    High-speed optical imaging is an indispensable technology for blur-free observation of fast transient dynamics in virtually all areas including science, industry, defense, energy, and medicine. High temporal resolution is particularly important for microscopy as even a slow event appears to occur "fast" in a small field of view. Unfortunately, the shutter speed and frame rate of conventional cameras based on electronic image sensors are significantly constrained by their electrical operation and limited storage. Over the recent years, several unique and unconventional approaches to high-speed optical imaging have been reported to circumvent these technical challenges and achieve a frame rate and shutter speed far beyond what can be reached with the conventional image sensors. In this article, we review the concepts and principles of such ultrafast optical imaging methods, compare their advantages and disadvantages, and discuss an entirely new class of applications that are possible using them.

  1. Optical Synchrotron Radiation Beam Imaging with a Digital Mask

    Energy Technology Data Exchange (ETDEWEB)

    Fiorito, R. B. [University of Maryland, College Park, MD (United States); Zhang, H. D. [University of Maryland, College Park, MD (United States); Corbett, W. J. [SLAC, Menlo Park, CA (United States); Fisher, A. S. [SLAC, Menlo Park, CA (United States); Mok, W. Y. [SLAC, Menlo Park, CA (United States); Tian, K. [SLAC, Menlo Park, CA (United States); Douglas, D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wilson, F. G. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Zhang, S. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Mitsuhashi, T. M. [KEK, Tsukuba (Japan); Shkvarunets, A. G. [University of Maryland, College Park, MD (United States)

    2012-11-01

    We have applied a new imaging/optical masking technique, which employs a digital micro-mirror device (DMD) and optical synchrotron radiation (OSR), to perform high dynamic range (DR) beam imaging at the JLAB Energy Recovery Linac and the SLAC/SPEAR3 Synchrotron Light Source. The OSR from the beam is first focused onto the DMD to produce a primary image; selected areas of this image are spatially filtered by controlling the state of individual micro-mirrors; and finally, the filtered image is refocused onto a CCD camera. At JLAB this technique has been used successfully to view the beam halo with a DR ~ 105. At SPEAR3 the DMD was used to filter out the bright core of the stored beam to study the turn-by-turn dynamics of the 10-3 weaker injected beam. We describe the optical performance, present limitations and our plans to improve the DR of both experimental systems.

  2. A novel multimodal optical imaging system for early detection of oral cancer

    Science.gov (United States)

    Malik, Bilal H.; Jabbour, Joey M.; Cheng, Shuna; Cuenca, Rodrigo; Cheng, Yi-Shing Lisa; Wright, John M.; Jo, Javier A.; Maitland, Kristen C.

    2015-01-01

    Objectives Several imaging techniques have been advocated as clinical adjuncts to improve identification of suspicious oral lesions. However, these have not yet shown superior sensitivity or specificity over conventional oral examination techniques. We developed a multimodal, multi-scale optical imaging system that combines macroscopic biochemical imaging of fluorescence lifetime imaging (FLIM) with subcellular morphologic imaging of reflectance confocal microscopy (RCM) for early detection of oral cancer. We tested our system on excised human oral tissues. Study Design A total of four tissue specimen were imaged. These specimens were diagnosed as one each: clinically normal, oral lichen planus, gingival hyperplasia, and superficially-invasive squamous cell carcinoma (SCC). The optical and fluorescence lifetime properties of each specimen were recorded. Results Both quantitative and qualitative differences between normal, benign and SCC lesions can be resolved with FLIM-RCM imaging. The results demonstrate that an integrated approach based on these two methods can potentially enable rapid screening and evaluation of large areas of oral epithelial tissue. Conclusions Early results from ongoing studies of imaging human oral cavity illustrate the synergistic combination of the two modalities. An adjunct device based on such optical characterization of oral mucosa can potentially be used to detect oral carcinogenesis in early stages. PMID:26725720

  3. Identification of clouds and aurorae in optical data images

    CERN Document Server

    Seviour, R; Honary, F

    2003-01-01

    In this paper we present an automatic image recognition technique used to identify clouds and aurorae in digital images, taken with a CCD all-sky imager. The image recognition algorithm uses image segmentation to generate a binary block object image. Object analysis is then performed on the binary block image, the results of which are used to assess whether clouds, aurorae and stars are present in the original image. The need for such an algorithm arises because the optical study of particle precipitation into the Earth's atmosphere by the Ionosphere and Radio Propagation Group at Lancaster generates vast data-sets, over 25 000 images/year, making manual classification of all the images impractical.

  4. Combined optical coherence tomography and intravascular ultrasound radio frequency data analysis for plaque characterization. Classification accuracy of human coronary plaques in vitro

    NARCIS (Netherlands)

    T.P.M. Goderie; G. van Soest (Gijs); H.M. Garcia-Garcia (Hector); N. Gonzalo (Nieves); S. Koljenovic (Senada); G.J.H.L. Leenders (Geert); F. Mastik (Frits); E.S. Regar (Eveline); J.W. Oosterhuis (Wolter); P.W.J.C. Serruys (Patrick); A.F.W. van der Steen (Ton)

    2010-01-01

    textabstractThis study was performed to characterize coronary plaque types by optical coherence tomography (OCT) and intravascular ultrasound (IVUS) radiofrequency (RF) data analysis, and to investigate the possibility of error reduction by combining these techniques. Intracoronary imaging methods h

  5. Evaluation of a combined index of optic nerve structure and function for glaucoma diagnosis

    Directory of Open Access Journals (Sweden)

    Quigley Harry A

    2011-02-01

    Full Text Available Abstract Background The definitive diagnosis of glaucoma is currently based on congruent damage to both optic nerve structure and function. Given widespread quantitative assessment of both structure (imaging and function (automated perimetry in glaucoma, it should be possible to combine these quantitative data to diagnose disease. We have therefore defined and tested a new approach to glaucoma diagnosis by combining imaging and visual field data, using the anatomical organization of retinal ganglion cells. Methods Data from 1499 eyes of glaucoma suspects and 895 eyes with glaucoma were identified at a single glaucoma center. Each underwent Heidelberg Retinal Tomograph (HRT imaging and standard automated perimetry. A new measure combining these two tests, the structure function index (SFI, was defined in 3 steps: 1 calculate the probability that each visual field point is abnormal, 2 calculate the probability of abnormality for each of the six HRT optic disc sectors, and 3 combine those probabilities with the probability that a field point and disc sector are linked by ganglion cell anatomy. The SFI was compared to the HRT and visual field using receiver operating characteristic (ROC analysis. Results The SFI produced an area under the ROC curve (0.78 that was similar to that for both visual field mean deviation (0.78 and pattern standard deviation (0.80 and larger than that for a normalized measure of HRT rim area (0.66. The cases classified as glaucoma by the various tests were significantly non-overlapping. Based on the distribution of test values in the population with mild disease, the SFI may be better able to stratify this group while still clearly identifying those with severe disease. Conclusions The SFI reflects the traditional clinical diagnosis of glaucoma by combining optic nerve structure and function. In doing so, it identifies a different subset of patients than either visual field testing or optic nerve head imaging alone

  6. Compact MEMS/NEMS characterization platform using a DVD optical pick-up unit with optical imaging function

    DEFF Research Database (Denmark)

    Liao, Hsien-Shun; Hwang, Ing-Shouh; Chen, Ching-Hsiu

    2013-01-01

    In this work, we present a compact, simple and efficient platform for Micro-electromechanical systems (MEMS)/Nano-electromechanical systems (NEMS) characterization. In this platform, a CCD camera is combined with a DVD optical pick-up unit (OPU). The CCD camera captures optical image of MEMS....../NEMS samples and detection laser spot, which makes laser alignment on measurement target easier. The DVD OPU is used for detection of resonant frequency measurements of the samples. Working bandwidth and noise level of the OPU are 100 MHz and 1.3 pmHz"2, respectively. Furthermore, the OPU has a laser spot size...

  7. Computational imaging through a fiber-optic bundle

    Science.gov (United States)

    Lodhi, Muhammad A.; Dumas, John Paul; Pierce, Mark C.; Bajwa, Waheed U.

    2017-05-01

    Compressive sensing (CS) has proven to be a viable method for reconstructing high-resolution signals using low-resolution measurements. Integrating CS principles into an optical system allows for higher-resolution imaging using lower-resolution sensor arrays. In contrast to prior works on CS-based imaging, our focus in this paper is on imaging through fiber-optic bundles, in which manufacturing constraints limit individual fiber spacing to around 2 μm. This limitation essentially renders fiber-optic bundles as low-resolution sensors with relatively few resolvable points per unit area. These fiber bundles are often used in minimally invasive medical instruments for viewing tissue at macro and microscopic levels. While the compact nature and flexibility of fiber bundles allow for excellent tissue access in-vivo, imaging through fiber bundles does not provide the fine details of tissue features that is demanded in some medical situations. Our hypothesis is that adapting existing CS principles to fiber bundle-based optical systems will overcome the resolution limitation inherent in fiber-bundle imaging. In a previous paper we examined the practical challenges involved in implementing a highly parallel version of the single-pixel camera while focusing on synthetic objects. This paper extends the same architecture for fiber-bundle imaging under incoherent illumination and addresses some practical issues associated with imaging physical objects. Additionally, we model the optical non-idealities in the system to get lower modelling errors.

  8. Optical double image encryption employing a pseudo image technique in the Fourier domain

    Science.gov (United States)

    Guo, Changliang; Liu, Shi; Sheridan, John T.

    2014-06-01

    A novel optical encryption method is proposed involving double image encryption in which one image is introduced as the pseudo image while the other is the original object image. The Double Random Phase Encoding technique is used to encrypt both the pseudo and object images into complex images. A unique binary image is then employed to first generate the random phase key for the object image encryption and then to embed the encrypted object image into the encrypted pseudo image, which acts as host image. Both the second random phase mask used for encoding the pseudo image and the binary image act as encryption keys. If an attacker attempts to crack the random phase key and decrypt the original object image, the pseudo image will be obtained instead. Simulation results and robustness tests are performed which demonstrate the feasibility of the algorithm.

  9. Finite-difference time-domain-based optical microscopy simulation of dispersive media facilitates the development of optical imaging techniques

    Science.gov (United States)

    Zhang, Di; Capoglu, Ilker; Li, Yue; Cherkezyan, Lusik; Chandler, John; Spicer, Graham; Subramanian, Hariharan; Taflove, Allen; Backman, Vadim

    2016-06-01

    Combining finite-difference time-domain (FDTD) methods and modeling of optical microscopy modalities, we previously developed an open-source software package called Angora, which is essentially a "microscope in a computer." However, the samples being simulated were limited to nondispersive media. Since media dispersions are common in biological samples (such as cells with staining and metallic biomarkers), we have further developed a module in Angora to simulate samples having complicated dispersion properties, thereby allowing the synthesis of microscope images of most biological samples. We first describe a method to integrate media dispersion into FDTD, and we validate the corresponding Angora dispersion module by applying Mie theory, as well as by experimentally imaging gold microspheres. Then, we demonstrate how Angora can facilitate the development of optical imaging techniques with a case study.

  10. Photometric Calibration of the Gemini South Adaptive Optics Imager

    Science.gov (United States)

    Stevenson, Sarah Anne; Rodrigo Carrasco Damele, Eleazar; Thomas-Osip, Joanna

    2017-01-01

    The Gemini South Adaptive Optics Imager (GSAOI) is an instrument available on the Gemini South telescope at Cerro Pachon, Chile, utilizing the Gemini Multi-Conjugate Adaptive Optics System (GeMS). In order to allow users to easily perform photometry with this instrument and to monitor any changes in the instrument in the future, we seek to set up a process for performing photometric calibration with standard star observations taken across the time of the instrument’s operation. We construct a Python-based pipeline that includes IRAF wrappers for reduction and combines the AstroPy photutils package and original Python scripts with the IRAF apphot and photcal packages to carry out photometry and linear regression fitting. Using the pipeline, we examine standard star observations made with GSAOI on 68 nights between 2013 and 2015 in order to determine the nightly photometric zero points in the J, H, Kshort, and K bands. This work is based on observations obtained at the Gemini Observatory, processed using the Gemini IRAF and gemini_python packages, which is operated by the Association of Universities for Research in Astronomy, Inc., under a cooperative agreement with the NSF on behalf of the Gemini partnership: the National Science Foundation (United States), the National Research Council (Canada), CONICYT (Chile), Ministerio de Ciencia, Tecnología e Innovación Productiva (Argentina), and Ministério da Ciência, Tecnologia e Inovação (Brazil).

  11. Numerical methods for forward and inverse problems in optical imaging

    Science.gov (United States)

    Gao, Hao

    The main objective of this work is to develop efficient and accurate numerical algorithms for mathematical problems in optical imaging: forward modeling and inverse problems. Radiative transfer equation (RTE) can be regarded as the gold standard of modeling in vivo photon migration, however an efficient solver of RTE is extremely computationally challenging. In this work we develop a fast multigrid solver for steady-state or frequency-domain RTE on 2D and 3D structured and unstructured meshes with vacuum or reflection boundary condition. The error estimate and convergence analysis of the algorithm is given. The subsequent effort is devoted to quantitatively improve the reconstruction from ill-posed problems, such as multilevel approach with L1+TV regularization for bioluminescence tomography, multilevel regularization for diffuse optical tomography, linear complex-source method for fluorescence tomography, and Bregman method for quantitative photoacoustic tomography. Most of the developed methods are general in the sense that they are not limited to a particular reconstruction problem and can be combined in a synergetic way.

  12. New variational image decomposition model for simultaneously denoising and segmenting optical coherence tomography images.

    Science.gov (United States)

    Duan, Jinming; Tench, Christopher; Gottlob, Irene; Proudlock, Frank; Bai, Li

    2015-11-21

    Optical coherence tomography (OCT) imaging plays an important role in clinical diagnosis and monitoring of diseases of the human retina. Automated analysis of optical coherence tomography images is a challenging task as the images are inherently noisy. In this paper, a novel variational image decomposition model is proposed to decompose an OCT image into three components: the first component is the original image but with the noise completely removed; the second contains the set of edges representing the retinal layer boundaries present in the image; and the third is an image of noise, or in image decomposition terms, the texture, or oscillatory patterns of the original image. In addition, a fast Fourier transform based split Bregman algorithm is developed to improve computational efficiency of solving the proposed model. Extensive experiments are conducted on both synthesised and real OCT images to demonstrate that the proposed model outperforms the state-of-the-art speckle noise reduction methods and leads to accurate retinal layer segmentation.

  13. Focal-Plane Imaging of Crossed Beams in Nonlinear Optics Experiments

    Science.gov (United States)

    Bivolaru, Daniel; Herring, G. C.

    2007-01-01

    An application of focal-plane imaging that can be used as a real time diagnostic of beam crossing in various optical techniques is reported. We discuss two specific versions and demonstrate the capability of maximizing system performance with an example in a combined dual-pump coherent anti-Stokes Raman scattering interferometric Rayleigh scattering experiment (CARS-IRS). We find that this imaging diagnostic significantly reduces beam alignment time and loss of CARS-IRS signals due to inadvertent misalignments.

  14. Magneto-optical system for high speed real time imaging

    Science.gov (United States)

    Baziljevich, M.; Barness, D.; Sinvani, M.; Perel, E.; Shaulov, A.; Yeshurun, Y.

    2012-08-01

    A new magneto-optical system has been developed to expand the range of high speed real time magneto-optical imaging. A special source for the external magnetic field has also been designed, using a pump solenoid to rapidly excite the field coil. Together with careful modifications of the cryostat, to reduce eddy currents, ramping rates reaching 3000 T/s have been achieved. Using a powerful laser as the light source, a custom designed optical assembly, and a high speed digital camera, real time imaging rates up to 30 000 frames per seconds have been demonstrated.

  15. Fiber optic direct Raman imaging system based on a hollow-core fiber bundle

    Science.gov (United States)

    Inoue, S.; Katagiri, T.; Matsuura, Y.

    2015-03-01

    A Raman imaging system which combined a hollow fiber bundle and a direct imaging technique was constructed for high-speed endoscopic Raman imaging. The hollow fiber bundle is fabricated by depositing a silver thin film on the inner surface of pre-drawn glass capillary bundle. It performs as a fiber optic probe which transmits a Raman image with high signal-to-noise ratio because the propagating light is confined into the air core inducing little light scattering. The field of view on the sample is uniformly irradiated by the excitation laser light via the probe. The back-scattered image is collected by the probe and captured directly by an image sensor. A pair of thin film tunable filters is used to select target Raman band. This imaging system enables flexible and high-speed Raman imaging of biological tissues.

  16. A General Epipolar-Line Model between Optical and SAR Images and Used in Image Matching

    Directory of Open Access Journals (Sweden)

    Shuai Xing

    2014-02-01

    Full Text Available The search space and strategy are important for optical and SAR image matching. In this paper a general epipolar-line model has been proposed between linear array push-broom optical and SAR images. Then a dynamic approximate epipolar-line constraint model (DAELCM has been constructed and used to construct a new image matching algorithm with Harris operator and CRA. Experimental results have shown that the general epipolar-line model is valid and successfully used in optical and SAR image matching, and effectively limits the search space and decreased computation.

  17. Review on Matching Infrared Face Images to Optical Face Images using LBP

    Directory of Open Access Journals (Sweden)

    Kamakhaya Argulewar

    2014-12-01

    Full Text Available In biometric research and many security areas, it is very difficult task to match the images which is captured by different devices. Large gap exist between them because they relates with different classes. Matching optical face images to infrared face images is one of the difficult task in face biometric. Large difference exists between infrared and optical face images because they belong to multiple classes. Converting the samples of multimodality into common feature space is the main objective of this project. Different class of images is relating by coordinating separate feature for classes .It is mainly used in heterogeneous face recognition. The new method has been developing for identification of heterogeneous face identification. Training set contains the images from different modalities. Initially the infrared image is preprocessed by applying Gaussian filter, difference of Gaussian and CSDN filters are apply on infrared face image. After preprocessing next step to extracting the feature by using LBP(local binary pattern feature extraction then relevance machine classifier is used to identify the best matching optical image from the corresponding infrared images from the optical images dataset. By processing this technique our system efficiently match the infrared and optical face images.

  18. AFM Imaging of Natural Optical Structures

    Directory of Open Access Journals (Sweden)

    Dinara Sultanovna Dallaeva

    2014-01-01

    Full Text Available The research in this field is focused to the investigation of biological structures with superior optical features. The study presents atomic force microscopy of biological optical structures on butterfly wings. The bright blue and dark black color scales exhibit the different topography. These scales were compared to the visually the same color scales of other two species of butterflies. The histograms of heights distribution are presented and show similar results for the scales of one color for different species.

  19. Nonlinear Interferometric Vibrational Imaging (NIVI) with Novel Optical Sources

    Science.gov (United States)

    Boppart, Stephen A.; King, Matthew D.; Liu, Yuan; Tu, Haohua; Gruebele, Martin

    Optical imaging is essential in medicine and in fundamental studies of biological systems. Although many existing imaging modalities can supply valuable information, not all are capable of label-free imaging with high-contrast and molecular specificity. The application of molecular or nanoparticle contrast agents may adversely influence the biological system under investigation. These substances also present ongoing concerns over toxicity or particle clearance, which must be properly addressed before their approval for in vivo human imaging. Hence there is an increasing appreciation for label-free imaging techniques. It is of primary importance to develop imaging techniques that can indiscriminately identify and quantify biochemical compositions to high degrees of sensitivity and specificity through only the intrinsic optical response of endogenous molecular species. The development and use of nonlinear interferometric vibrational imaging, which is based on the interferometric detection of optical signals from coherent anti-Stokes Raman scattering (CARS), along with novel optical sources, offers the potential for label-free molecular imaging.

  20. Compensating focusing for space hyper spectral imager's fore optical system

    Institute of Scientific and Technical Information of China (English)

    Yicha Zhang; Wei Liu

    2011-01-01

    @@ The performance of space hyper spectral imager is severely affected by turbulent orbit temperature. Turbulence results in a defocus in the fore optical system of the imager. To address this problem, a focusing system is added. A number of simulation methods are applied on the fore optical system to study the relationship between temperature and focusing. In addition, this process is conducted to obtain a practical reference for focusing while the imager is flying on orbit. The obtained correlation between focusing and temperature is proven effective based on ground imaging and simulation testing.%The performance of space hyper spectral imager is severely affected by turbulent orbit temperature. Turbulence results in a defocus in the fore optical system of the imager. To address this problem, a focusing system is added. A number of simulation methods are applied on the fore optical system to study the relationship between temperature and focusing. In addition, this process is conducted to obtain a practical reference for focusing while the imager is flying on orbit. The obtained correlation between focusing and temperature is proven effective based on ground imaging and simulation testing.

  1. Fast optical measurements and imaging of flow mixing

    DEFF Research Database (Denmark)

    Clausen, Sønnik; Fateev, Alexander; Nielsen, Karsten Lindorff

    in combustion enhancement can be also obtained. The infrared camera was also used together with special endoscope optics for fast thermal imaging of a coal-straw flame in an industrial boiler. Obtained time-resolved infrared images provided useful information for the diagnostics of the flame and fuel...

  2. Optical Molecular Imaging of Ultrasound-mediated Drug Delivery

    NARCIS (Netherlands)

    Derieppe, M.P.P.

    2015-01-01

    The goal of this PhD project was to develop optical molecular imaging methods to study drug delivery facilitated by ultrasound waves (US) and hyperthermia. Fibered confocal fluorescence microscopy (FCFM), together with dedicated image analysis, was used in vitro on a cell monolayer, and in vivo at

  3. Coherence-Gated Sensorless Adaptive Optics Multiphoton Retinal Imaging

    Science.gov (United States)

    Cua, Michelle; Wahl, Daniel J.; Zhao, Yuan; Lee, Sujin; Bonora, Stefano; Zawadzki, Robert J.; Jian, Yifan; Sarunic, Marinko V.

    2016-09-01

    Multiphoton microscopy enables imaging deep into scattering tissues. The efficient generation of non-linear optical effects is related to both the pulse duration (typically on the order of femtoseconds) and the size of the focused spot. Aberrations introduced by refractive index inhomogeneity in the sample distort the wavefront and enlarge the focal spot, which reduces the multiphoton signal. Traditional approaches to adaptive optics wavefront correction are not effective in thick or multi-layered scattering media. In this report, we present sensorless adaptive optics (SAO) using low-coherence interferometric detection of the excitation light for depth-resolved aberration correction of two-photon excited fluorescence (TPEF) in biological tissue. We demonstrate coherence-gated SAO TPEF using a transmissive multi-actuator adaptive lens for in vivo imaging in a mouse retina. This configuration has significant potential for reducing the laser power required for adaptive optics multiphoton imaging, and for facilitating integration with existing systems.

  4. Perfect imaging in the optical domain using dielectric materials

    CERN Document Server

    Gabrielli, Lucas H; Lipson, Michal

    2010-01-01

    The promise of perfect imaging in the optical domain, where light can be imaged without aberrations and with ultra-high resolution, could revolutionize technology and nanofabrication [1, 2, 3, 4, 5, 6]. Recently it has been shown theoretically that perfect imaging can be achieved in a dielectric medium with spatially varying refractive index [7, 8]. The lens geometry is defined using transformation optics [9, 10, 11, 12, 13, 14, 15] for projecting a spherical space onto a real plane space, forming Maxwells fish eye [16, 17, 18, 19]. Most transformation optics demonstrations have been achieved for Euclidean spaces and in the microwave regime, due to ease of fabrication. Here we demonstrate a transformation to a non-Euclidean space [20] in the optical regime using silicon nanophotonic structures.

  5. Coherence-Gated Sensorless Adaptive Optics Multiphoton Retinal Imaging.

    Science.gov (United States)

    Cua, Michelle; Wahl, Daniel J; Zhao, Yuan; Lee, Sujin; Bonora, Stefano; Zawadzki, Robert J; Jian, Yifan; Sarunic, Marinko V

    2016-09-07

    Multiphoton microscopy enables imaging deep into scattering tissues. The efficient generation of non-linear optical effects is related to both the pulse duration (typically on the order of femtoseconds) and the size of the focused spot. Aberrations introduced by refractive index inhomogeneity in the sample distort the wavefront and enlarge the focal spot, which reduces the multiphoton signal. Traditional approaches to adaptive optics wavefront correction are not effective in thick or multi-layered scattering media. In this report, we present sensorless adaptive optics (SAO) using low-coherence interferometric detection of the excitation light for depth-resolved aberration correction of two-photon excited fluorescence (TPEF) in biological tissue. We demonstrate coherence-gated SAO TPEF using a transmissive multi-actuator adaptive lens for in vivo imaging in a mouse retina. This configuration has significant potential for reducing the laser power required for adaptive optics multiphoton imaging, and for facilitating integration with existing systems.

  6. Digital optical cellular image processor (DOCIP) - Experimental implementation

    Science.gov (United States)

    Huang, K.-S.; Sawchuk, A. A.; Jenkins, B. K.; Chavel, P.; Wang, J.-M.; Weber, A. G.; Wang, C.-H.; Glaser, I.

    1993-01-01

    We demonstrate experimentally the concept of the digital optical cellular image processor architecture by implementing one processing element of a prototype optical computer that includes a 54-gate processor, an instruction decoder, and electronic input-output interfaces. The processor consists of a two-dimensional (2-D) array of 54 optical logic gates implemented by use of a liquid-crystal light valve and a 2-D array of 53 subholograms to provide interconnections between gates. The interconnection hologram is fabricated by a computer-controlled optical system.

  7. MR imaging of optic neuritis using short TI IR

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Kohichi; Uehara, Masako; Ashikaga, Ryuichirou; Inoue, Masaaki; Shindou, Hiroshi; Mabuchi, Nobuhisa; Yoshioka, Hiroyasu; Hamada, Tatsumi; Ishida, Osamu (Kinki Univ., Osaka (Japan). School of Medicine)

    1990-12-01

    We evaluated the ability of MRI using short TI inversion recovery (STIR) to diagnose optic neuritis. Eleven patients with previous or recent attack of optic neuritis were studied with MRI at 0.5 tesla. STIR images revealed high signal regions in 7 of 12 symptomatic and 5 of 10 asymptomatic nerves. Three of five asymptomatic nerves with high intensity were pertinent to the cases with past attack and seemed to reflect the demyelinating change. The other two nerves were pertinent to the cases without past attack and seemed to show occult lesions. We consider that STIR is useful in detection of optic nerve lesions associated with optic neuritis. (author).

  8. Extracting optical scattering properties on the basis of phase contrast images for diagnosing stomach cancer

    Science.gov (United States)

    Li, Zhifang; Li, Hui; Zhang, Hui; Lin, Xiaona; Chen, Wei R.

    2013-04-01

    We combine morphological granulometry with Mie theory in order to analyze phase contrast images of biomedical tissue for cancer diagnosis. This method correlates microscopic phase distributions of the tissue image and macroscopic optical scattering properties of the tissue. Our results show that the particle size density distribution can be used to quantitatively identify morphological changes of cancerous stomach tissues. Our method can distinguish normal tissue from cancerous tissues, using the significant differences in scattering coefficient, reduced scattering coefficient and phase function. Therefore, this method can provide not only quantitative information for the diagnosis of cancer, but also accurate optical scattering parameters for photothermal therapy for cancer.

  9. Direct model fitting to combine dithered ACS images

    CERN Document Server

    Mahmoudian, Haniyeh

    2013-01-01

    The information lost in images of undersampled CCD cameras can be recovered with the technique of `dithering'. A number of subexposures is taken with sub-pixel shifts in order to record structures on scales smaller than a pixel. The standard method to combine such exposures, `Drizzle', averages after reversing the displacements, including rotations and distortions. More sophisticated methods are available to produce, e.g., Nyquist sampled representations of band-limited inputs. While the combined images produced by these methods can be of high quality, their use as input for forward-modelling techniques in gravitational lensing is still not optimal, because the residual artefacts still affect the modelling results in unpredictable ways. In this paper we argue for an overall modelling approach that takes into account the dithering and the lensing without the intermediate product of a combined image. As one building block we introduce an alternative approach to combine dithered images by direct model fitting wi...

  10. Image analysis and microscopy: a useful combination

    Directory of Open Access Journals (Sweden)

    Pinotti L.

    2009-01-01

    Full Text Available The TSE Roadmap published in 2005 (DG for Health and Consumer Protection, 2005 suggests that short and medium term (2005-2009 amendments to control BSE policy should include “a relaxation of certain measures of the current total feed ban when certain conditions are met”. The same document noted “the starting point when revising the current feed ban provisions should be risk-based but at the same time taking into account the control tools in place to evaluate and ensure the proper implementation of this feed ban”. The clear implication is that adequate analytical methods to detect constituents of animal origin in feedstuffs are required. The official analytical method for the detection of constituents of animal origin in feedstuffs is the microscopic examination technique as described in Commission Directive 2003/126/EC of 23 December 2003 [OJ L 339, 24.12.2003, 78]. Although the microscopic method is usually able to distinguish fish from land animal material, it is often unable to distinguish between different terrestrial animals. Fulfillments of the requirements of Regulation 1774/2002/EC laying down health rules concerning animal by-products not intended for human consumption, clearly implies that it must be possible to identify the origin animal materials, at higher taxonomic levels than in the past. Thus improvements in all methods of detecting constituents of animal origin are required, including the microscopic method. This article will examine the problem of meat and bone meal in animal feeds, and the use of microscopic methods in association with computer image analysis to identify the source species of these feedstuff contaminants. Image processing, integrated with morphometric measurements can provide accurate and reliable results and can be a very useful aid to the analyst in the characterization, analysis and control of feedstuffs.

  11. Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

    Science.gov (United States)

    Downie, John D.

    1990-01-01

    A ground-based adaptive optics imaging telescope system attempts to improve image quality by detecting and correcting for atmospherically induced wavefront aberrations. The required control computations during each cycle will take a finite amount of time. Longer time delays result in larger values of residual wavefront error variance since the atmosphere continues to change during that time. Thus an optical processor may be well-suited for this task. This paper presents a study of the accuracy requirements in a general optical processor that will make it competitive with, or superior to, a conventional digital computer for the adaptive optics application. An optimization of the adaptive optics correction algorithm with respect to an optical processor's degree of accuracy is also briefly discussed.

  12. Chemical shift selective magnetic resonance imaging of the optic nerve in patients with acute optic neuritis

    DEFF Research Database (Denmark)

    Larsson, H B; Thomsen, C; Frederiksen, J

    1988-01-01

    of the 16 patients, abnormalities were seen. In one patient with bilateral symptoms, signal hyperintensity and swelling of the right side of the chiasm were found. In another patient the optic nerve was found diffusely enlarged with only a marginally increased signal in the second echo. In the third patient......Optic neuritis is often the first manifestation of multiple sclerosis (MS). Sixteen patients with acute optic neuritis and one patient with benign intracranial hypertension (BIH) were investigated by magnetic resonance imaging, using a chemical shift selective double spin echo sequence. In 3...... an area of signal hyperintensity and swelling was seen in the left optic nerve. In the patient with BIH the subarachnoid space which surrounds the optic nerves was enlarged. Even using this refined pulse sequence, avoiding the major artefact in imaging the optic nerve, the chemical shift artefact, lesions...

  13. Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

    Science.gov (United States)

    Downie, John D.

    1990-01-01

    A ground-based adaptive optics imaging telescope system attempts to improve image quality by detecting and correcting for atmospherically induced wavefront aberrations. The required control computations during each cycle will take a finite amount of time. Longer time delays result in larger values of residual wavefront error variance since the atmosphere continues to change during that time. Thus an optical processor may be well-suited for this task. This paper presents a study of the accuracy requirements in a general optical processor that will make it competitive with, or superior to, a conventional digital computer for the adaptive optics application. An optimization of the adaptive optics correction algorithm with respect to an optical processor's degree of accuracy is also briefly discussed.

  14. Diffusion MR Imaging of Postoperative Bilateral Acute Ischemic Optic Neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, Anusha; Srinivasan, Sivasubramanian [Khoo Teck Puat Hospital, Singapore (Singapore)

    2012-09-15

    We read with great interest, the case report on ischemic optic neuropathy (1). We would like to add a few points concerning the blood supply of the optic nerve and the correlation with the development of post-operative ischemic neuropathy. Actually, the perioperative or post-operative vision loss (postoperative ischemic neuropathy) is most likely due to ischemic optic neuropathy. Ischemic optic neuropathy (2) is classified as an anterior ischemic optic neuropathy (AION) and posterior ischemic optic neuropathy (PION). This classification is based on the fact that blood supply (2) to the anterior segment of the optic nerve (part of the optic nerve in the scleral canal and the optic disc) is supplied by short posterior ciliary vessels or anastamotic ring branches around the optic nerve. The posterior part of the optic canal is relatively less perfused, and is supplied by ophthalmic artery and central fibres are perfused by a central retinal artery. So, in the post-operative period, the posterior part of the optic nerve is more vulnerable for ischemia, especially, after major surgeries (3), one of the theories being hypotension or anaemia (2) and resultant decreased perfusion. The onset of PION is slower than the anterior ischemic optic neuropathy. AION on the other hand, is usually spontaneous (idiopathic) or due to arteritis, and is usually sudden in its onset. The reported case is most likely a case of PION. The role of imaging, especially the diffusion weighted magnetic resonance imaging, is very important because the ophthalmoscopic findings in early stages of PION is normal, and it may delay the diagnosis. On the other hand, edema of the disc is usually seen in the early stages of AION.

  15. Multimodal nonlinear optical imaging of cartilage development in mouse model

    Science.gov (United States)

    He, Sicong; Xue, Wenqian; Sun, Qiqi; Li, Xuesong; Huang, Jiandong; Qu, Jianan Y.

    2017-02-01

    Kinesin-1 is a kind of motor protein responsible for intracellular transportation and has been studied in a variety of tissues. However, its roles in cartilage development are not clear. In this study, a kinesin-1 heavy chain (Kif5b) knockout mouse model is used to study the functions of kinesin-1 in the cartilage development. We developed a multimodal nonlinear optical (NLO) microscope system integrating stimulated Raman scattering (SRS), second harmonic generation (SHG) and two-photon excited fluorescence (TPEF) to investigate the morphological and biomedical characteristics of fresh tibial cartilage from normal and mutant mice at different developmental stages. The combined forward and backward SHG imaging resolved the fine structure of collagen fibrils in the extracellular matrix of cartilage. Meanwhile, the chondrocyte morphology in different zones of cartilage was visualized by label-free SRS and TPEF images. The results show that the fibrillar collagen in the superficial zone of cartilage in postnatal day 10 and 15 (P10 and P15) knockout mice was significantly less than that of control mice. Moreover, we observed distorted morphology and disorganization of columnar arrangement of chondrocytes in the growth plate cartilage of mutant mice. This study reveals the significant roles of kinesin-1 in collagen formation and chondrocyte morphogenesis.

  16. Time-gated optical imaging through turbid media using stimulated Raman scattering: Studies on image contrast

    Indian Academy of Sciences (India)

    K Divakar Rao; H S Patel; B Jain; P K Gupta

    2005-02-01

    In this paper, we report the development of experimental set-up for timegated optical imaging through turbid media using stimulated Raman scattering. Our studies on the contrast of time-gated images show that for a given optical thickness, the image contrast is better for sample with lower scattering coefficient and higher physical thickness, and that the contrast improves with decreasing value of anisotropy parameters of the scatterers. These results are consistent with time-resolved Monte Carlo simulations.

  17. Stochastic Optics: A Scattering Mitigation Framework for Radio Interferometric Imaging

    CERN Document Server

    Johnson, Michael D

    2016-01-01

    Just as turbulence in the Earth's atmosphere can severely limit the angular resolution of optical telescopes, turbulence in the ionized interstellar medium fundamentally limits the resolution of radio telescopes. We present a scattering mitigation framework for radio imaging with very long baseline interferometry (VLBI) that partially overcomes this limitation. Our framework, "stochastic optics," derives from a simplification of strong interstellar scattering to separate small-scale ("diffractive") effects from large-scale ("refractive") effects, thereby separating deterministic and random contributions to the scattering. Stochastic optics extends traditional synthesis imaging by simultaneously reconstructing an unscattered image and its refractive perturbations. Its advantages over direct imaging come from utilizing the many deterministic properties of the scattering -- such as the time-averaged "blurring," polarization independence, and the deterministic evolution in frequency and time -- while still accoun...

  18. Nanoscale live cell optical imaging of the dynamics of intracellular microvesicles in neural cells.

    Science.gov (United States)

    Lee, Sohee; Heo, Chaejeong; Suh, Minah; Lee, Young Hee

    2013-11-01

    Recent advances in biotechnology and imaging technology have provided great opportunities to investigate cellular dynamics. Conventional imaging methods such as transmission electron microscopy, scanning electron microscopy, and atomic force microscopy are powerful techniques for cellular imaging, even at the nanoscale level. However, these techniques have limitations applications in live cell imaging because of the experimental preparation required, namely cell fixation, and the innately small field of view. In this study, we developed a nanoscale optical imaging (NOI) system that combines a conventional optical microscope with a high resolution dark-field condenser (Cytoviva, Inc.) and halogen illuminator. The NOI system's maximum resolution for live cell imaging is around 100 nm. We utilized NOI to investigate the dynamics of intracellular microvesicles of neural cells without immunocytological analysis. In particular, we studied direct, active random, and moderate random dynamic motions of intracellular microvesicles and visualized lysosomal vesicle changes after treatment of cells with a lysosomal inhibitor (NH4Cl). Our results indicate that the NOI system is a feasible, high-resolution optical imaging system for live small organelles that does not require complicated optics or immunocytological staining processes.

  19. An Analysis of the Magneto-Optic Imaging System

    Science.gov (United States)

    Nath, Shridhar

    1996-01-01

    The Magneto-Optic Imaging system is being used for the detection of defects in airframes and other aircraft structures. The system has been successfully applied to detecting surface cracks, but has difficulty in the detection of sub-surface defects such as corrosion. The intent of the grant was to understand the physics of the MOI better, in order to use it effectively for detecting corrosion and for classifying surface defects. Finite element analysis, image classification, and image processing are addressed.

  20. Application of optical coherence tomography based microangiography for cerebral imaging

    Science.gov (United States)

    Baran, Utku; Wang, Ruikang K.

    2016-03-01

    Requirements of in vivo rodent brain imaging are hard to satisfy using traditional technologies such as magnetic resonance imaging and two-photon microscopy. Optical coherence tomography (OCT) is an emerging tool that can easily reach at high speeds and provide high resolution volumetric images with a relatively large field of view for rodent brain imaging. Here, we provide the overview of recent developments of functional OCT based imaging techniques for neuroscience applications on rodents. Moreover, a summary of OCT-based microangiography (OMAG) studies for stroke and traumatic brain injury cases on rodents are provided.

  1. Imaging photothermal microscopy for absorption measurements of optical coatings

    Institute of Scientific and Technical Information of China (English)

    Chunxian Tao; Yuanan Zhao; Hongbo He; Dawei Li; Jianda Shao; Zhengxiu Fan

    2009-01-01

    @@ For absorption measurement of large-aperture optical coatings, a novel method of imaging photothermal microscopy based on image lock-in technique is presented.Detailed theoretical analysis and numerical calculation are made based on the image photothermal technique.The feasibility of this imaging method is proved through the coincidence between the theoretical results of single spot method and multi-channel method.The measuring speed of this imaging method can be increased hundreds of times compared with that of the raster scanning.This technique can expand the applications of photothermal technique.

  2. Multiple irradiation sensing of the optical effective attenuation coefficient for spectral correction in handheld OA imaging

    Directory of Open Access Journals (Sweden)

    K. Gerrit Held

    2016-06-01

    Full Text Available Spectral optoacoustic (OA imaging enables spatially-resolved measurement of blood oxygenation levels, based on the distinct optical absorption spectra of oxygenated and de-oxygenated blood. Wavelength-dependent optical attenuation in the bulk tissue, however, distorts the acquired OA spectrum and thus makes quantitative oxygenation measurements challenging. We demonstrate a correction for this spectral distortion without requiring a priori knowledge of the tissue optical properties, using the concept of multiple irradiation sensing: recording the OA signal amplitude of an absorbing structure (e.g. blood vessel, which serves as an intrinsic fluence detector, as function of irradiation position. This permits the reconstruction of the bulk effective optical attenuation coefficient μeff,λ. If performed at various irradiation wavelengths, a correction for the wavelength-dependent fluence attenuation is achieved, revealing accurate spectral information on the absorbing structures. Phantom studies were performed to show the potential of this technique for handheld clinical combined OA and ultrasound imaging.

  3. Optical image hiding based on computational ghost imaging

    Science.gov (United States)

    Wang, Le; Zhao, Shengmei; Cheng, Weiwen; Gong, Longyan; Chen, Hanwu

    2016-05-01

    Imaging hiding schemes play important roles in now big data times. They provide copyright protections of digital images. In the paper, we propose a novel image hiding scheme based on computational ghost imaging to have strong robustness and high security. The watermark is encrypted with the configuration of a computational ghost imaging system, and the random speckle patterns compose a secret key. Least significant bit algorithm is adopted to embed the watermark and both the second-order correlation algorithm and the compressed sensing (CS) algorithm are used to extract the watermark. The experimental and simulation results show that the authorized users can get the watermark with the secret key. The watermark image could not be retrieved when the eavesdropping ratio is less than 45% with the second-order correlation algorithm, whereas it is less than 20% with the TVAL3 CS reconstructed algorithm. In addition, the proposed scheme is robust against the 'salt and pepper' noise and image cropping degradations.

  4. Ultrathin Optics for Low-Profile Innocuous Imager

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Robert R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photonic Microsystems Technologies; Brady, Gregory Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photonic Microsystems Technologies; Nelson, Cynthia Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Systems Engineering I; Briggs, Ronald D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Integrated Microdevice Systems; Jared, Bradley Howell [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Prototyping S& T; Warren, Mial E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Microsystems Partnerships

    2009-09-01

    This project demonstrates the feasibility of a novel imager with a thickness measured in microns rather than inches. Traditional imaging systems, i.e. cameras, cannot provide both the necessary resolution and innocuous form factor required in many data acquisition applications. Designing an imaging system with an extremely thin form factor (less than 1 mm) immediately presents several technical challenges. For instance, the thickness of the optical lens must be reduced drastically from currently available lenses. Additionally, the image circle is reduced by a factor equal to the reduction in focal length. This translates to fewer detector pixels across the image. To reduce the optical total track requires the use of specialized micro-optics and the required resolution necessitates the use of a new imaging modality. While a single thin imager will not produce the desired output, several thin imagers can be multiplexed and their low resolution (LR) outputs used together in post-processing to produce a high resolution (HR) image. The utility of an Iterative Back Projection (IBP) algorithm has been successfully demonstrated for performing the required post-processing. Advanced fabrication of a thin lens was also demonstrated and experimental results using this lens as well as commercially available lenses are presented.

  5. Contrasting properties of zinc oxide nanoparticles and titanium dioxide nanoparticles for optical coherence tomography imaging of human normal endometrium tissues and uterine leiomyoma tissues in ex vivo study combined with microneedle

    Science.gov (United States)

    Gu, P. C.; Ye, M.; Wei, H. J.; Wu, G. Y.; Guo, Z. Y.; Yang, H. Q.; He, Y. H.; Xie, S. S.; Zhou, L. P.

    2016-05-01

    The aims of this study were to monitor and contrast the diffusion of zinc oxide (ZnO) and titanium dioxide (TiO2) nanoparticles’ (NPs) penetration and accumulation in human normal endometrium (NE) tissues and uterine leiomyoma (UL) tissues combined with microneedles (MN) in vitro using optical coherence tomography (OCT) and diffuse reflectance (DR) spectral. Continuous OCT and DR spectra monitoring showed that, after application of ZnO or TiO2 NPs, the OCT signal intensities of NE and UL both increase with time, and the TiO2 NPs tend to produce a greater signal enhancement than ZnO NPs in the same type of tissue. And for the same type of NPs, they penetrate faster in NE tissue compared with UL tissue. In addition, the use of MN can significantly enhance the penetration of topically applied ZnO or TiO2 NPs in the tissue. The attenuation coefficients of NE tissue are about 5.01  ±  0.35 mm-1 for ZnO NPs treatment at 195 min and 4.62  ±  0.29 mm-1 for ZnO NPs/MN at 179 min, 4.73  ±  0.30 mm-1 for TiO2 NPs at 183 min, 4.05  ±  0.25 mm-1 for TiO2 NPs/MN at 147 min when the penetration process reached the stable state. And the attenuation coefficients of UL tissue are about 5.0  ±  0.34 mm-1 for ZnO NP treatment at 191 min and 4.20  ±  0.26 mm-1 for ZnO NPs/MN at 169 min, 4.33  ±  0.27 mm-1 for TiO2 NPs at 176 min, 3.53  ±  0.20 mm-1 for TiO2 NPs/MN at 141 min when the penetration process reached the stable state. This suggests that TiO2 NPs penetrate faster and reach the maximum amount of penetration earlier than ZnO NPs with the same condition. The results of attenuation coefficients and reflectance intensity of NE and UL tissue suggests that the accumulation of the TiO2 or ZnO NPs in both NE and UL tissue greatly influenced the tissue optical properties.

  6. Compound focusing mirror and X-ray waveguide optics for coherent imaging and nano-diffraction.

    Science.gov (United States)

    Salditt, Tim; Osterhoff, Markus; Krenkel, Martin; Wilke, Robin N; Priebe, Marius; Bartels, Matthias; Kalbfleisch, Sebastian; Sprung, Michael

    2015-07-01

    A compound optical system for coherent focusing and imaging at the nanoscale is reported, realised by high-gain fixed-curvature elliptical mirrors in combination with X-ray waveguide optics or different cleaning apertures. The key optical concepts are illustrated, as implemented at the Göttingen Instrument for Nano-Imaging with X-rays (GINIX), installed at the P10 coherence beamline of the PETRA III storage ring at DESY, Hamburg, and examples for typical applications in biological imaging are given. Characteristic beam configurations with the recently achieved values are also described, meeting the different requirements of the applications, such as spot size, coherence or bandwidth. The emphasis of this work is on the different beam shaping, filtering and characterization methods.

  7. SAR and Oblique Aerial Optical Image Fusion for Urban Area Image Segmentation

    Science.gov (United States)

    Fagir, J.; Schubert, A.; Frioud, M.; Henke, D.

    2017-05-01

    The fusion of synthetic aperture radar (SAR) and optical data is a dynamic research area, but image segmentation is rarely treated. While a few studies use low-resolution nadir-view optical images, we approached the segmentation of SAR and optical images acquired from the same airborne platform - leading to an oblique view with high resolution and thus increased complexity. To overcome the geometric differences, we generated a digital surface model (DSM) from adjacent optical images and used it to project both the DSM and SAR data into the optical camera frame, followed by segmentation with each channel. The fused segmentation algorithm was found to out-perform the single-channel version.

  8. OPUS: optoacoustic imaging combined with conventional ultrasound for breast cancer detection

    Science.gov (United States)

    Haisch, C.; Zell, K.; Sperl, J. I.; Ketzer, S.; Vogel, M. W.; Menzenbach, P.; Niessner, R.

    2007-07-01

    Besides x-ray imaging, sonography is the most common method for breast cancer screening. The intention of our work is to develop optoacoustical imaging as an add-on to a conventional system. While ultrasound imaging reveals acoustical properties of tissue, optoacoustics generates an image of the distribution of optical absorption. Hence, it can be a valuable addition to sonography, because acoustical properties of different tissues show only a slight variation whereas the optical properties may differ strongly. Additionally, optoacoustics gives access to physiological parameters, like oxygen saturation of blood. For the presented work, we combine a conventional ultrasound system to a 100 Hz laser. The laser system consists of a Nd:YAG-laser at a wavelength of 532 nm with 7 ns pulse duration, coupled to a tunable Optical Parametric Oscillator (OPO) with a tuning rage from 680 nm to 2500 nm. The tunable laser source allows the selection of wavelengths which compromising high spectral information content with high skin transmission. The laser pulse is delivered fiber-optically to the ultrasound transducer and coupled into the acoustical field of view. Homogeneous illumination is crucial in order to achieve unblurred images. Furthermore the maximum allowed pulse intensities in accordance with standards for medical equipment have to be met to achieve a high signal to noise ration. The ultrasound instrument generates the trigger signal which controls the laser pulsing in order to apply ultrasound instrument's imaging procedures without major modifications to generate an optoacoustic image. Detection of the optoacoustic signal as well as of the classical ultrasound signal is carried out by the standard medical ultrasound transducer. The characterization of the system, including quantitative measurements, performed on tissue phantoms, is presented. These phantoms have been specially designed regarding their acoustical as well as their optical properties.

  9. Ex vivo imaging of human thyroid pathology using integrated optical coherence tomography and optical coherence microscopy

    Science.gov (United States)

    Zhou, Chao; Wang, Yihong; Aguirre, Aaron D.; Tsai, Tsung-Han; Cohen, David W.; Connolly, James L.; Fujimoto, James G.

    2010-01-01

    We evaluate the feasibility of optical coherence tomography (OCT) and optical coherence microscopy (OCM) for imaging of benign and malignant thyroid lesions ex vivo using intrinsic optical contrast. 34 thyroid gland specimens are imaged from 17 patients, covering a spectrum of pathology ranging from normal thyroid to benign disease/neoplasms (multinodular colloid goiter, Hashimoto's thyroiditis, and follicular adenoma) and malignant thyroid tumors (papillary carcinoma and medullary carcinoma). Imaging is performed using an integrated OCT and OCM system, with sections. Characteristic features that suggest malignant lesions, such as complex papillary architecture, microfollicules, psammomatous calcifications, or replacement of normal follicular architecture with sheets/nests of tumor cells, can be identified from OCT and OCM images and are clearly differentiable from normal or benign thyroid tissues. With further development of needle-based imaging probes, OCT and OCM could be promising techniques to use for the screening of thyroid nodules and to improve the diagnostic specificity of fine needle aspiration evaluation.

  10. AFM imaging of natural optical structures

    Science.gov (United States)

    Dallaeva, Dinara; Tománek, Pavel; Prokopyeva, Elena; Kaspar, Pavel; Grmela, Lubomír.; Škarvada, Pavel

    2015-01-01

    The colors of some living organisms assosiated with the surface structure. Irridesence butterfly wings is an example of such coloration. Optical effects such as interference, diffraction, polarization are responsible for physical colors appearance. Alongside with amazing beauty this structure represent interest for design of optical devices. Here we report the results of morphology investigation by atomic force microscopy. The difference in surface structure of black and blue wings areas is clearly observed. It explains the angle dependence of the wing blue color, since these micrometer and sub-micrometer quasiperiodical structures could control the light propagation, absorption and reflection.

  11. Detection in Urban Scenario Using Combined Airborne Imaging Sensors

    NARCIS (Netherlands)

    Renhorn, I.; Axelsson, M.; Benoist, K.W.; Bourghys, D.; Boucher, Y.; Xavier Briottet, X.; Sergio De CeglieD, S. De; Dekker, R.J.; Dimmeler, A.; Dost, R.; Friman, O.; Kåsen, I.; Maerker, J.; Persie, M. van; Resta, S.; Schwering, P.B.W.; Shimoni, M.; Vegard Haavardsholm, T.

    2012-01-01

    The EDA project “Detection in Urban scenario using Combined Airborne imaging Sensors” (DUCAS) is in progress. The aim of the project is to investigate the potential benefit of combined high spatial and spectral resolution airborne imagery for several defense applications in the urban area. The proje

  12. Detection in Urban Scenario using Combined Airborne Imaging Sensors

    NARCIS (Netherlands)

    Renhorn, I.; Axelsson, M.; Benoist, K.W.; Bourghys, D.; Boucher, Y.; Xavier Briottet, X.; Sergio De CeglieD, S. De; Dekker, R.J.; Dimmeler, A.; Dost, R.; Friman, O.; Kåsen, I.; Maerker, J.; Persie, M. van; Resta, S.; Schwering, P.B.W.; Shimoni, M.; Vegard Haavardsholm, T.

    2012-01-01

    The EDA project “Detection in Urban scenario using Combined Airborne imaging Sensors” (DUCAS) is in progress. The aim of the project is to investigate the potential benefit of combined high spatial and spectral resolution airborne imagery for several defense applications in the urban area. The proje

  13. An improved image reconstruction method for optical intensity correlation Imaging

    Science.gov (United States)

    Gao, Xin; Feng, Lingjie; Li, Xiyu

    2016-12-01

    The intensity correlation imaging method is a novel kind of interference imaging and it has favorable prospects in deep space recognition. However, restricted by the low detecting signal-to-noise ratio (SNR), it's usually very difficult to obtain high-quality image of deep space object like high-Earth-orbit (HEO) satellite with existing phase retrieval methods. In this paper, based on the priori intensity statistical distribution model of the object and characteristics of measurement noise distribution, an improved method of Prior Information Optimization (PIO) is proposed to reduce the ambiguous images and accelerate the phase retrieval procedure thus realizing fine image reconstruction. As the simulations and experiments show, compared to previous methods, our method could acquire higher-resolution images with less error in low SNR condition.

  14. Improving resolution of optical coherence tomography for imaging of microstructures

    Science.gov (United States)

    Shen, Kai; Lu, Hui; Wang, James H.; Wang, Michael R.

    2015-03-01

    Multi-frame superresolution technique has been used to improve the lateral resolution of spectral domain optical coherence tomography (SD-OCT) for imaging of 3D microstructures. By adjusting the voltages applied to ? and ? galvanometer scanners in the measurement arm, small lateral imaging positional shifts have been introduced among different C-scans. Utilizing the extracted ?-? plane en face image frames from these specially offset C-scan image sets at the same axial position, we have reconstructed the lateral high resolution image by the efficient multi-frame superresolution technique. To further improve the image quality, we applied the latest K-SVD and bilateral total variation denoising algorithms to the raw SD-OCT lateral images before and along with the superresolution processing, respectively. The performance of the SD-OCT of improved lateral resolution is demonstrated by 3D imaging a microstructure fabricated by photolithography and a double-layer microfluidic device.

  15. Collinear, two-color optical Kerr effect shutter for ultrafast time-resolved imaging

    CERN Document Server

    Purwar, Harsh; Rozé, Claude; Sedarsky, David; Blaisot, Jean-Bernard

    2015-01-01

    Imaging with ultrashort exposure times is generally achieved with a crossed-beam geometry. In the usual arrangement, an off-axis gating pulse induces birefringence in a medium exhibiting a strong Kerr response (commonly carbon disulfide) which is followed by a polarizer aligned to fully attenuate the on-axis imaging beam. By properly timing the gate pulse, imaging light experiences a polarization change allowing time-dependent transmission through the polarizer to form an ultrashort image. The crossed-beam system is effective in generating short gate times, however, signal transmission through the system is complicated by the crossing angle of the gate and imaging beams. This work presents a robust ultrafast time-gated imaging scheme based on a combination of type-I frequency doubling and a collinear optical arrangement in carbon disulfide. We discuss spatial effects arising from crossed-beam Kerr gating, and examine the imaging spatial resolution and transmission timing affected by collinear activation of th...

  16. Computed Optical Interferometric Imaging: Methods, Achievements, and Challenges.

    Science.gov (United States)

    South, Fredrick A; Liu, Yuan-Zhi; Carney, P Scott; Boppart, Stephen A

    2016-01-01

    Three-dimensional high-resolution optical imaging systems are generally restricted by the trade-off between resolution and depth-of-field as well as imperfections in the imaging system or sample. Computed optical interferometric imaging is able to overcome these longstanding limitations using methods such as interferometric synthetic aperture microscopy (ISAM) and computational adaptive optics (CAO) which manipulate the complex interferometric data. These techniques correct for limited depth-of-field and optical aberrations without the need for additional hardware. This paper aims to outline these computational methods, making them readily available to the research community. Achievements of the techniques will be highlighted, along with past and present challenges in implementing the techniques. Challenges such as phase instability and determination of the appropriate aberration correction have been largely overcome so that imaging of living tissues using ISAM and CAO is now possible. Computed imaging in optics is becoming a mature technology poised to make a significant impact in medicine and biology.

  17. Optical design and characterization of an advanced computational imaging system

    Science.gov (United States)

    Shepard, R. Hamilton; Fernandez-Cull, Christy; Raskar, Ramesh; Shi, Boxin; Barsi, Christopher; Zhao, Hang

    2014-09-01

    We describe an advanced computational imaging system with an optical architecture that enables simultaneous and dynamic pupil-plane and image-plane coding accommodating several task-specific applications. We assess the optical requirement trades associated with custom and commercial-off-the-shelf (COTS) optics and converge on the development of two low-cost and robust COTS testbeds. The first is a coded-aperture programmable pixel imager employing a digital micromirror device (DMD) for image plane per-pixel oversampling and spatial super-resolution experiments. The second is a simultaneous pupil-encoded and time-encoded imager employing a DMD for pupil apodization or a deformable mirror for wavefront coding experiments. These two testbeds are built to leverage two MIT Lincoln Laboratory focal plane arrays - an orthogonal transfer CCD with non-uniform pixel sampling and on-chip dithering and a digital readout integrated circuit (DROIC) with advanced on-chip per-pixel processing capabilities. This paper discusses the derivation of optical component requirements, optical design metrics, and performance analyses for the two testbeds built.

  18. Combination of SVD and GLCM in forest image recognition

    Science.gov (United States)

    Xia, Deshen; Li, Hua; Qiu, Yong

    1996-12-01

    Feature extraction is the most fundamental and important problem in satellite forest image recognition problem, but how to extract the feature is an important step towards solving recognition problems. The forest image features commonly consist of visual feature, statistical feature, transform field feature, and algebraic feature. The paper uses SPOT remote sensing forest images as samples, SVD (singular value decomposition) and GLCM (gray-level co- occurrence matrix) as the methods of feature extraction, it also compares and analyzes these two methods. The results of comparison show that GLCM is more effective in describing the visual feature and SVD in describing the internal feature. Forest image statistical feature can describe the image macroscopic features, such as the texture feature shape feature, etc. But SVD can describe the image internal features. The SVD spectral features synthesize the features of image at the pixel level. The combination of the two methods can be more effective in the forest image recognition and classification. We use both SVD and GLCM to extract remote sensing forest image features, and by the combination of these two methods we have got a better recognition of the ground surface forest of remote sensing images than before. Our word shows that the forest recognition rate reaches up to 95%.

  19. Combined reflectance confocal microscopy-optical coherence tomography for delineation of basal cell carcinoma margins: an ex vivo study

    Science.gov (United States)

    Iftimia, Nicusor; Peterson, Gary; Chang, Ernest W.; Maguluri, Gopi; Fox, William; Rajadhyaksha, Milind

    2016-01-01

    We present a combined reflectance confocal microscopy (RCM) and optical coherence tomography (OCT) approach, integrated within a single optical layout, for diagnosis of basal cell carcinomas (BCCs) and delineation of margins. While RCM imaging detects BCC presence (diagnoses) and its lateral spreading (margins) with measured resolution of ˜1 μm, OCT imaging delineates BCC depth spreading (margins) with resolution of ˜7 μm. When delineating margins in 20 specimens of superficial and nodular BCCs, depth could be reliably determined down to ˜600 μm, and agreement with histology was within about ±50 μm.

  20. Radar model fusion of asteroid (4179) Toutatis via its optical images observed by Chang'e-2 probe

    Science.gov (United States)

    Zhao, Wei; Xiao, Ting; Liu, Peng; Sun, Lei; Huang, Jiangchuan; Tang, Xianglong

    2016-06-01

    Asteroid (4179) Toutatis has been modeling by ground-based radar observations until Dec 13th, 2012, when distinct optical images of Toutatis were captured during the Chang'e-2 flyby at the shortest distance for the first time. The surface details on Toutatis in the optical images are abundant enough to reinforce the radar model descriptions. Under this context, we customized a method of frequency domain data fusion, which combines the topography information of radar model and the 3rd dimension information estimated from optical image by shape from shading algorithm, and gave out a new Toutatis' radar model. A model with abundant surface characteristics had been resulted.

  1. Acoustic-optical imaging without immersion

    Science.gov (United States)

    Liu, H.

    1979-01-01

    System using membraneous end wall of Bragg cell to separate test specimen from acoustic transmission medium, operates in real time and uses readily available optical components. System can be easily set up and maintained by people with little or no training in holography.

  2. Design and manufacture of imaging time-of-propagation optics

    Science.gov (United States)

    Albrecht, Mike; Fast, James; Schwartz, Alan

    2016-09-01

    There are several challenges associated with the design and manufacture of the optics required for the imaging time-of- propagation detector constructed for the Belle II particle physics experiment. This detector uses Cherenkov light radiated in quartz bars to identify subatomic particles: pions, kaons, and protons. The optics are physically large (125 cm x 45 cm x 2 cm bars and 45 cm x 10 cm x 5 cm prisms), all surfaces are optically polished, and there is very little allowance for chamfers or surface defects. In addition to the optical challenges, there are several logistical and handling challenges associated with measuring, assembling, cleaning, packaging, and shipping these delicate precision optics. This paper describes a collaborative effort between Pacific Northwest National Laboratory, the University of Cincinnati, and ZYGO Corporation for the design and manufacture of 48 fused silica optics (30 bars and 18 prisms) for the iTOP Detector. Details of the iTOP detector design that drove the challenging optical requirements are provided, along with material selection considerations. Since the optics are so large, precise, and delicate, special care had to be given to the selection of a manufacturing process capable of achieving the challenging optical and surface defect requirements on such large and high-aspect-ratio (66:1) components. A brief update on the current status and performance of these optics is also provided.

  3. Image Combination Analysis in SPECAN Algorithm of Spaceborne SAR

    Institute of Scientific and Technical Information of China (English)

    臧铁飞; 李方慧; 龙腾

    2003-01-01

    An analysis of image combination in SPECAN algorithm is delivered in time-frequency domain in detail and a new image combination method is proposed. For four multi-looks processing one sub-aperture data in every three sub-apertures is processed in this combination method. The continual sub-aperture processing in SPECAN algorithm is realized and the processing efficiency can be dramatically increased. A new parameter is also put forward to measure the processing efficient of SAR image processing. Finally, the raw data of RADARSAT are used to test the method and the result proves that this method is feasible to be used in SPECAN algorithm of spaceborne SAR and can improve processing efficiently. SPECAN algorithm with this method can be used in quick-look imaging.

  4. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    Science.gov (United States)

    Olivier, Scot S.; Werner, John S.; Zawadzki, Robert J.; Laut, Sophie P.; Jones, Steven M.

    2010-09-07

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  5. Combining Digital Watermarks with Two-Color Bitmap Image

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A technology for combining digital watermarks with two-color bitmap image based on the threshold watermarking method is presented. Our technology doesn't add any thing to the digital media, but combines the watermarks in two-color bitmap image by looking for some characteristic values in the bitmap and uses the relationship between the watermarks and the characteristic values to prove the copyright protection. The choice of the characteristic values depends on the choice of a cryptographic key known by the owner of the bitmap. The benefit of using a cryptographic key is to combine the watermarks with the bitmap in a high secure way.

  6. Analog signal processing for optical coherence imaging systems

    Science.gov (United States)

    Xu, Wei

    Optical coherence tomography (OCT) and optical coherence microscopy (OCM) are non-invasive optical coherence imaging techniques, which enable micron-scale resolution, depth resolved imaging capability. Both OCT and OCM are based on Michelson interferometer theory. They are widely used in ophthalmology, gastroenterology and dermatology, because of their high resolution, safety and low cost. OCT creates cross sectional images whereas OCM obtains en face images. In this dissertation, the design and development of three increasingly complicated analog signal processing (ASP) solutions for optical coherence imaging are presented. The first ASP solution was implemented for a time domain OCT system with a Rapid Scanning Optical Delay line (RSOD)-based optical signal modulation and logarithmic amplifier (Log amp) based demodulation. This OCT system can acquire up to 1600 A-scans per second. The measured dynamic range is 106dB at 200A-scan per second. This OCT signal processing electronics includes an off-the-shelf filter box with a Log amp circuit implemented on a PCB board. The second ASP solution was developed for an OCM system with synchronized modulation and demodulation and compensation for interferometer phase drift. This OCM acquired micron-scale resolution, high dynamic range images at acquisition speeds up to 45,000 pixels/second. This OCM ASP solution is fully custom designed on a perforated circuit board. The third ASP solution was implemented on a single 2.2 mm x 2.2 mm complementary metal oxide semiconductor (CMOS) chip. This design is expandable to a multiple channel OCT system. A single on-chip CMOS photodetector and ASP channel was used for coherent demodulation in a time domain OCT system. Cross-sectional images were acquired with a dynamic range of 76dB (limited by photodetector responsivity). When incorporated with a bump-bonded InGaAs photodiode with higher responsivity, the expected dynamic range is close to 100dB.

  7. CT guided diffuse optical tomography for breast cancer imaging

    Science.gov (United States)

    Baikejiang, Reheman; Zhang, Wei; Zhu, Dianwen; Li, Changqing

    2016-03-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as blood, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer detection. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at wavelengths of 650 and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements, the width of measurement patch, have been investigated. Our results indicate that an EMCCD camera with air cooling is good enough for the transmission mode DOT imaging. We have also found that measurements at six projections are sufficient for DOT to reconstruct the optical targets with 4 times absorption contrast when the CT guidance is applied. Finally, we report our effort and progress on the integration of the multispectral DOT imaging system into a breast CT scanner.

  8. Driving micro-optical imaging systems towards miniature camera applications

    Science.gov (United States)

    Brückner, Andreas; Duparré, Jacques; Dannberg, Peter; Leitel, Robert; Bräuer, Andreas

    2010-05-01

    Up to now, multi channel imaging systems have been increasingly studied and approached from various directions in the academic domain due to their promising large field of view at small system thickness. However, specific drawbacks of each of the solutions prevented the diffusion into corresponding markets so far. Most severe problems are a low image resolution and a low sensitivity compared to a conventional single aperture lens besides the lack of a cost-efficient method of fabrication and assembly. We propose a microoptical approach to ultra-compact optics for real-time vision systems that are inspired by the compound eyes of insects. The demonstrated modules achieve a VGA resolution with 700x550 pixels within an optical package of 6.8mm x 5.2mm and a total track length of 1.4mm. The partial images that are separately recorded within different optical channels are stitched together to form a final image of the whole field of view by means of image processing. These software tools allow to correct the distortion of the individual partial images so that the final image is also free of distortion. The so-called electronic cluster eyes are realized by state-of-the-art microoptical fabrication techniques and offer a resolution and sensitivity potential that makes them suitable for consumer, machine vision and medical imaging applications.

  9. Multimodal backside imaging of a microcontroller using confocal laser scanning and optical-beam-induced current imaging

    Science.gov (United States)

    Finkeldey, Markus; Göring, Lena; Schellenberg, Falk; Brenner, Carsten; Gerhardt, Nils C.; Hofmann, Martin

    2017-02-01

    Microscopy imaging with a single technology is usually restricted to a single contrast mechanism. Multimodal imaging is a promising technique to improve the structural information that could be obtained about a device under test (DUT). Due to the different contrast mechanisms of laser scanning microscopy (LSM), confocal laser scanning microscopy (CLSM) and optical beam induced current microscopy (OBICM), a combination could improve the detection of structures in integrated circuits (ICs) and helps to reveal their layout. While OBIC imaging is sensitive to the changes between differently doped areas and to semiconductor-metal transitions, CLSM imaging is mostly sensitive to changes in absorption and reflection. In this work we present the implementation of OBIC imaging into a CLSM. We show first results using industry standard Atmel microcontrollers (MCUs) with a feature size of about 250nm as DUTs. Analyzing these types of microcontrollers helps to improve in the field of side-channel attacks to find hardware Trojans, possible spots for laser fault attacks and for reverse engineering. For the experimental results the DUT is placed on a custom circuit board that allows us to measure the current while imaging it in our in-house built stage scanning microscope using a near infrared (NIR) laser diode as light source. The DUT is thinned and polished, allowing backside imaging through the Si-substrate. We demonstrate the possibilities using this optical setup by evaluating OBIC, LSM and CLSM images above and below the threshold of the laser source.

  10. ADVANTAGES OF DIFFRACTIVE OPTICAL ELEMENTS APPLICATION IN SIMPLE OPTICAL IMAGING SYSTEMS

    Directory of Open Access Journals (Sweden)

    N. D. Zoric

    2015-01-01

    Full Text Available The paper deals with the influence of diffractive optical elements on the optical aberrations. The correction of optical aberrations was investigated in the simple optical systems with one and two lenses (singlet and doublet. The advantages of diffractive optical elements are their ability to generate arbitrary complex wave fronts from a piece of optical material that is essentially flat. The optical systems consisting of the standard surfaces were designed and optimized by using the same starting points. Further, the diffractive and aspheric surfaces were introduced into the developed systems. The resulting hybrid systems were optimized. To compare the complicity of the development of narrow field systems and wide field optical systems, the optimization has been done separately for these two types of the instruments. The optical systems were designed by using special Optical Design Software. Тhe characteristics of designed diffractive surfaces were controlled in Software DIFSYS 2.30. Due to the application of diffractive optical elements the longitudinal chromatic aberration was 5 times reduced for the narrow field systems. The absolute value of Seidel coefficient related to the spherical aberration was reduced in the range of 0.03. Considering that diffractive optical elements have the known disadvantages, like possible parasitic diffraction orders and probable decrease of the transmission, we also developed and analyzed the optical systems with combined aspheric and diffractive surfaces. A combination of the aspheric and diffractive surfaces in the optical disk system of the disk reading lens, gave cutting down of the longitudinal color aberrations almost 15 times on-axis, comparing to the lens consisting of the aspherical and standard surfaces. All of the designed diffractive optical elements possess the parameters within the fabrication limits.

  11. Optical double-image cryptography based on diffractive imaging with a laterally-translated phase grating.

    Science.gov (United States)

    Chen, Wen; Chen, Xudong; Sheppard, Colin J R

    2011-10-10

    In this paper, we propose a method using structured-illumination-based diffractive imaging with a laterally-translated phase grating for optical double-image cryptography. An optical cryptosystem is designed, and multiple random phase-only masks are placed in the optical path. When a phase grating is laterally translated just before the plaintexts, several diffraction intensity patterns (i.e., ciphertexts) can be correspondingly obtained. During image decryption, an iterative retrieval algorithm is developed to extract plaintexts from the ciphertexts. In addition, security and advantages of the proposed method are analyzed. Feasibility and effectiveness of the proposed method are demonstrated by numerical simulation results.

  12. Three-dimensional phase-contrast X-ray microtomography with scanning-imaging X-ray microscope optics.

    Science.gov (United States)

    Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio

    2013-09-01

    A three-dimensional (3D) X-ray tomographic micro-imaging system has been developed. The optical system is based on a scanning-imaging X-ray microscope (SIXM) optics, which is a hybrid system consisting of a scanning microscope optics with a one-dimensional (1D) focusing (line-focusing) device and an imaging microscope optics with a 1D objective. In the SIXM system, each 1D dataset of a two-dimensional (2D) image is recorded independently. An object is illuminated with a line-focused beam. Positional information of the region illuminated by the line-focused beam is recorded with the 1D imaging microscope optics as line-profile data. By scanning the object with the line focus, 2D image data are obtained. In the same manner as for a scanning microscope optics with a multi-pixel detector, imaging modes such as phase contrast and absorption contrast can be arbitrarily configured after the image data acquisition. By combining a tomographic scan method and the SIXM system, quantitative 3D imaging is performed. Results of a feasibility study of the SIXM for 3D imaging are shown.

  13. Habitable Exoplanet Imager Optical Telescope Concept Design

    Science.gov (United States)

    Stahl, H. Philip

    2017-01-01

    Habitable Exoplanet Imaging Mission (HabEx) is a concept for a mission to directly image and characterize planetary systems around Sun-like stars. In addition to the search for life on Earth-like exoplanets, HabEx will enable a broad range of general astrophysics science enabled by 100 to 2500 nm spectral range and 3 x 3 arc-minute FOV. HabEx is one of four mission concepts currently being studied for the 2020 Astrophysics Decadal Survey.

  14. OSA Imaging and Applied Optics Congress Support

    Science.gov (United States)

    2017-02-16

    contact our Grants Manager, Ewelina Osinska, at (202) 416-1934 or eosinska@osa.org. Sincerely, Marcia Lesky Deputy Senior Director Phone: 1-202-416...reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188) , 1215...applications from internationally recognized academic and industry leaders in the field. 1S. SUBJECT TERMS imaging, imaging systems, computational

  15. Optical asymmetric image encryption using gyrator wavelet transform

    Science.gov (United States)

    Mehra, Isha; Nishchal, Naveen K.

    2015-11-01

    In this paper, we propose a new optical information processing tool termed as gyrator wavelet transform to secure a fully phase image, based on amplitude- and phase-truncation approach. The gyrator wavelet transform constitutes four basic parameters; gyrator transform order, type and level of mother wavelet, and position of different frequency bands. These parameters are used as encryption keys in addition to the random phase codes to the optical cryptosystem. This tool has also been applied for simultaneous compression and encryption of an image. The system's performance and its sensitivity to the encryption parameters, such as, gyrator transform order, and robustness has also been analyzed. It is expected that this tool will not only update current optical security systems, but may also shed some light on future developments. The computer simulation results demonstrate the abilities of the gyrator wavelet transform as an effective tool, which can be used in various optical information processing applications, including image encryption, and image compression. Also this tool can be applied for securing the color image, multispectral, and three-dimensional images.

  16. Small Animal Radionuclide Imaging With Focusing Gamma-Ray Optics

    Energy Technology Data Exchange (ETDEWEB)

    Hill, R; Decker, T; Epstein, M; Ziock, K; Pivovaroff, M J; Craig, W W; Jernigan, J G; Barber, W B; Christensen, F E; Funk, T; Hailey, C J; Hasegawa, B H; Taylor, C

    2004-02-27

    Significant effort currently is being devoted to the development of noninvasive imaging systems that allow in vivo assessment of biological and biomolecular interactions in mice and other small animals. While physiological function in small animals can be localized and imaged using conventional radionuclide imaging techniques such as single-photon emission tomography (SPECT) and positron emission tomography (PET), these techniques inherently are limited to spatial resolutions of 1-2 mm. For this reason, we are developing a small animal radionuclide imaging system (SARIS) using grazing incidence optics to focus gamma-rays emitted by {sup 125}I and other radiopharmaceuticals. We have developed a prototype optic with sufficient accuracy and precision to focus the 27.5 keV photons from {sup 125}I onto a high-resolution imaging detector. Experimental measurements from the prototype have demonstrated that the optic can focus X-rays from a microfocus X-ray tube to a spot having physical dimensions (approximately 1500 microns half-power diameter) consistent with those predicted by theory. Our theoretical and numerical analysis also indicate that an optic can be designed and build that ultimately can achieve 100 {micro}m spatial resolution with sufficient efficiency to perform in vivo single photon emission imaging studies in small animal.

  17. Imaging vascular implants with optical coherence tomography

    Science.gov (United States)

    Barton, Jennifer K.; Dal Ponte, Donny B.; Williams, Stuart K.; Ford, Bridget K.; Descour, Michael R.

    2000-04-01

    Vascular stents and grafts have many proven and promising clinical applications, but also a large number of complications. A focus of current research is the development of biocompatible implants. Evaluation of these devices generally requires a large number of animals due to the need for explanation and histological evaluation of the implant at several time intervals. It would be desirable to use instead a high resolution, in situ assessment method. An in vitro study was performed to determine if OCT could image cell proliferation and thrombus formation on vascular stents and grafts. First, images were taken of explanted stents. The implants were locate din peripheral vessels of a porcine model of atherosclerosis. The images clearly show the vessel response to initial damage, the materials of the implant, extent of intimal cell hyper proliferation, and small platelet aggregates. Next, a tissue engineered graft, which had been sodded with smooth muscle cells and incubated in a bioreactor, was evaluated. Cross-section images showed the pores of the polymer material and the layer of smooth muscle cells beginning to invade the graft material. For comparison, in vitro 20 MHz IVUS images of the same grafts were obtained. A catheter was designed for intravascular imaging. The 2.3 mm diameter catheter contains a fiber with GRIN lens and right angle prism, a monorail guidewire, and a novel positioning wire that can be protruded to push the catheter against the vessel wall, potentially eliminating the need for saline flush. Preliminary in vitro results with this catheter are encouraging.

  18. Combined holographic-mechanical optical tweezers: Construction, optimization, and calibration

    Energy Technology Data Exchange (ETDEWEB)

    Hanes, Richard D. L.; Jenkins, Matthew C.; Egelhaaf, Stefan U. [Condensed Matter Physics Laboratory, Heinrich-Heine University, 40225 Duesseldorf (Germany)

    2009-08-15

    A spatial light modulator (SLM) and a pair of galvanometer-mounted mirrors (GMM) were combined into an optical tweezers setup. This provides great flexibility as the SLM creates an array of traps, which can be moved smoothly and quickly with the GMM. To optimize performance, the effect of the incidence angle on the SLM with respect to phase and intensity response was investigated. Although it is common to use the SLM at an incidence angle of 45 deg., smaller angles give a full 2{pi} phase shift and an output intensity which is less dependent on the magnitude of the phase shift. The traps were calibrated using an active oscillatory technique and a passive probability distribution method.

  19. Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

    Science.gov (United States)

    Mungas, Greg S. (Inventor); Boynton, John (Inventor); Sepulveda, Cesar A. (Inventor); Nunes de Sepulveda, legal representative, Alicia (Inventor); Gursel, Yekta (Inventor)

    2012-01-01

    An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

  20. Optical Imaging Sensors and Systems for Homeland Security Applications

    CERN Document Server

    Javidi, Bahram

    2006-01-01

    Optical and photonic systems and devices have significant potential for homeland security. Optical Imaging Sensors and Systems for Homeland Security Applications presents original and significant technical contributions from leaders of industry, government, and academia in the field of optical and photonic sensors, systems and devices for detection, identification, prevention, sensing, security, verification and anti-counterfeiting. The chapters have recent and technically significant results, ample illustrations, figures, and key references. This book is intended for engineers and scientists in the relevant fields, graduate students, industry managers, university professors, government managers, and policy makers. Advanced Sciences and Technologies for Security Applications focuses on research monographs in the areas of -Recognition and identification (including optical imaging, biometrics, authentication, verification, and smart surveillance systems) -Biological and chemical threat detection (including bios...

  1. Normative data of outer photoreceptor layer thickness obtained by software image enhancing based on Stratus optical coherence tomography images

    DEFF Research Database (Denmark)

    Christensen, U.C.; Krøyer, K.; Thomadsen, Jakob

    2008-01-01

    Aim: To present normative data of outer photoreceptor layer thickness obtained by a new semiautomatic image analysis algorithm operating on contrast-enhanced optical coherence tomography (OCT) images. Methods: Eight Stratus OCT3 scans from identical retinal locations from 25 normal eyes were...... registered and combined to form a contrast-enhanced average image. Utilising the vertical intensity gradients of the enhanced OCT images to demarcate retinal layers, thickness measurements of the outer photoreceptor- and retinal pigment epithelium layer (RPE-OScomplex) were obtained. Additionally...... in the superior macula 0.5-3 mm of the centre was significantly increased as compared with the corresponding inferior retina. In healthy subjects, the I-ratio-ONL was 1.06. Conclusions: Contrast-enhanced OCT images enable quantification of outer photoreceptor layer thickness, and normative values may help...

  2. All-optical photoacoustic imaging system using fiber ultrasound probe and hollow optical fiber bundle.

    Science.gov (United States)

    Miida, Yusuke; Matsuura, Yuji

    2013-09-23

    An all-optical 3D photoacoustic imaging probe that consists of an optical fiber probe for ultrasound detection and a bundle of hollow optical fibers for excitation of photoacoustic waves was developed. The fiber probe for ultrasound is based on a single-mode optical fiber with a thin polymer film attached to the output end surface that works as a Fabry Perot etalon. The input end of the hollow fiber bundle is aligned so that each fiber in the bundle is sequentially excited. A thin and flexible probe can be obtained because the probe system does not have a scanning mechanism at the distal end.

  3. 3D tomographic breast imaging in-vivo using a handheld optical imager

    Science.gov (United States)

    Erickson, Sarah J.; Martinez, Sergio; Gonzalez, Jean; Roman, Manuela; Nunez, Annie; Godavarty, Anuradha

    2011-02-01

    Hand-held optical imagers are currently developed toward clinical imaging of breast tissue. However, the hand-held optical devices developed to are not able to coregister the image to the tissue geometry for 3D tomography. We have developed a hand-held optical imager which has demonstrated automated coregistered imaging and 3D tomography in phantoms, and validated coregistered imaging in normal human subjects. Herein, automated coregistered imaging is performed in a normal human subject with a 0.45 cm3 spherical target filled with 1 μM indocyanine green (fluorescent contrast agent) placed superficially underneath the flap of the breast tissue. The coregistered image data is used in an approximate extended Kalman filter (AEKF) based reconstruction algorithm to recover the 3D location of the target within the breast tissue geometry. The results demonstrate the feasibility of performing 3D tomographic imaging and recovering a fluorescent target in breast tissue of a human subject for the first time using a hand-held based optical imager. The significance of this work is toward clinical imaging of breast tissue for cancer diagnostics and therapy monitoring.

  4. Evaluation of Fingerprint Images Captured by Optical Fingerprint Scanner

    Science.gov (United States)

    Takeuchi, Hideyo; Matsumoto, Noriyuki; Kuwayama, Kiyoaki; Umezaki, Taizo

    In this paper, we propose the way to evaluate fingerprint image-quality and how to discriminate remnants from captured images. First, we investigate evaluating fingerprint image-quality. Fingerprint image-quality can be digitized using the "measure" we proposed. We simulate using the dataset consists of 1425 fingerprint images captured from 57 people in Feb, which contains a lot of faded images. In the simulation using all our database, recognition rate is 95.6% while type II error is 0.01%. Recognition rate is improved to 98.1%, with rejecting 3.7% faded images evaluated by our measure from the database. Recognition rate is improved to 99.6%, rejecting 14.2% faded images. And we investigate the way to apply the measure of image-quality to fingerprint verification device with customer’s satisfaction in real world. Next we propose the way to discriminate between remnants and fingerprint images captured from optical scanner by using frequency analysis. We can perfectly prevent the fingerprint verification device from malfunctioning caused by remnant, when strong flashlight or direct sunlight slant in optical scanner in real world.

  5. A wrapper-based strategy to jointly combine remote sensing image segmentation and object detection

    Science.gov (United States)

    Wang, Jun; Xie, Baoguo; Zhang, Meng; Yin, Wenjun; Du, Hui; Tang, Yujia

    2017-04-01

    Geospatial Object-Based Image Analysis (GEOBIA) has emerged as a new paradigm for remote sensing image classification and interpretation over the last two decades. However, due to the different sensor spatial characteristics, image timing, viewing geometry, etc., the object-based assumption was challenged across a whole scene when dealing with those targets with highly heterogeneous internal characteristics. In this paper we go one step further and address the problem of object detection using a wrapper-based strategy to jointly combine image segmentation and object detection. It offers an insight into full exploitation of the available remotely sensed data. Object detection and image interpretation not only rely on information from raw images, but also depend on knowledge of the target even knowledge from the outside world beyond the image. Regarding this issue, we used high-level object constraint knowledge to refine the image segmentation, going beyond bottom-up models and considering higher order cliques behind the image contexts. As segmentation helps recognition and recognized or delineated objects constrain segmentation, meanwhile, the "correct" segmentation is somehow a compromise between Top-Down & Bottom-Up segmentation. The framework of the proposed approach suggested that the high resolution satellite image was preprocessed, and then the wrapper-based strategy that jointly combined image segmentation and object detection was conducted to represent and interpreted the total scene. In fact, if image objects are badly constructed, objects cannot be accurately identified and recognized. The key idea of this study is to adopt the wrapper-based strategy for remote sensing image analysis, which enables hierarchically representation and recognition of remote sensing images. This kind of representation is determined by the physical properties of the geospatial objects and implemented based on the multi-scale scheme of real world geospatial objects. The method

  6. Characterizing and imaging magnetic nanoparticles by optical magnetometry

    Science.gov (United States)

    Weis, A.; Colombo, S.; Dolgovskiy, V.; Grujić, Z. D.; Lebedev, V.; Zhang, J.

    2017-01-01

    We review our ongoing work on deploying optical (atomic) magnetometry for measuring the magnetic response of magnetic nanoparticle (MNP) samples, yielding MNP size distributions, and other sample parameters like Néel relaxation time τ, saturation magnetisation Ms , anisotropy constant K and magnetic susceptibility χ. We address magnetorelaxation (MRX) signals, in which the decaying magnetisation M(t) following a magnetising pulse is recorded by a single atomic magnetometer or by a novel magnetic source imaging camera (MSIC) allowing spatially resolved MRX studies of distributed MNP samples. We further show that optical magnetometers can be used for a direct measurement of the M(H) and dM/dH(H) dependencies of MNP samples, the latter forming the basis for an optical magnetometer implementation of the MPI (Magnetic Particle Imaging) method. All experiments are in view of developing biomedical imaging modalities.

  7. Combining elastic and resonant inelastic optical spectroscopies for multiscale probing of embedded nanoparticle architectures

    Science.gov (United States)

    Farcau, Cosmin; Bonafos, Caroline; Benzo, Patrizio; Benassayag, Gerard; Carles, Robert

    2010-11-01

    Composite materials consisting of metal nanoparticles (NPs) embedded in a dielectric matrix have a great potential for photonic and plasmonic applications. A set of expensive, time-consuming, and destructive methods (like electron microscopy, electron energy loss, or secondary ion mass spectroscopy) are extensively being used for the structural characterization of such buried NP assemblies. Here, we show the power of combining complementary, noninvasive optical techniques to characterize planar arrays of Ag NPs embedded in a silica film. We use UV-Vis optical reflectivity and resonant Brillouin-Raman scattering, sustained by simulations, to show the sensitivity of these methods to the presence, density, size distribution, and spatial localization of NPs. The accuracy of the results is validated by transmission electron microscopy investigations. Finally the method is applied to obtain images of embedded plasmonic structures from reflectivity and Raman scanning microscopy.

  8. Localization and Imaging of Integrated Circuit Defect Using Simple Optical Feedback Detection

    Directory of Open Access Journals (Sweden)

    Vernon Julius Cemine

    2004-12-01

    Full Text Available High-contrast microscopy of semiconductor and metal edifices in integrated circuits is demonstrated by combining laser-scanning confocal reflectance microscopy, one-photon optical-beam-induced current (1P-OBIC imaging, and optical feedback detection via a commercially available semiconductor laser that also serves as the excitation source. The confocal microscope has a compact in-line arrangement with no external photodetector. Confocal and 1P-OBIC images are obtained simultaneously from the same focused beam that is scanned across the sample plane. Image pairs are processed to generate exclusive high-contrast distributions of the semiconductor, metal, and dielectric sites in a GaAs photodiode array sample. The method is then utilized to demonstrate defect localization and imaging in an integrated circuit.

  9. Validation of Dynamic optical coherence tomography for non-invasive, in vivo microcirculation imaging of the skin

    DEFF Research Database (Denmark)

    Themstrup, L.; Welzel, Julia; Ciardo, Silvana

    2016-01-01

    Objectives: Dynamic optical coherence tomography (D-OCT) is an angiographic variation of OCT that non-invasively provides images of the in vivo microvasculature of the skin by combining conventional OCT images with flow data. The objective of this study was to investigate and report on the D-OCT ...

  10. Radiation-induced optic neuropathy: A magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Guy, J.; Mancuso, A.; Beck, R.; Moster, M.L.; Sedwick, L.A.; Quisling, R.G.; Rhoton, A.L. Jr.; Protzko, E.E.; Schiffman, J. (Univ. of Florida, Gainesville (USA))

    1991-03-01

    Optic neuropathy induced by radiation is an infrequent cause of delayed visual loss that may at times be difficult to differentiate from compression of the visual pathways by recurrent neoplasm. The authors describe six patients with this disorder who experienced loss of vision 6 to 36 months after neurological surgery and radiation therapy. Of the six patients in the series, two had a pituitary adenoma and one each had a metastatic melanoma, multiple myeloma, craniopharyngioma, and lymphoepithelioma. Visual acuity in the affected eyes ranged from 20/25 to no light perception. Magnetic resonance (MR) imaging showed sellar and parasellar recurrence of both pituitary adenomas, but the intrinsic lesions of the optic nerves and optic chiasm induced by radiation were enhanced after gadolinium-diethylenetriaminepenta-acetic acid (DTPA) administration and were clearly distinguishable from the suprasellar compression of tumor. Repeated MR imaging showed spontaneous resolution of gadolinium-DTPA enhancement of the optic nerve in a patient who was initially suspected of harboring recurrence of a metastatic malignant melanoma as the cause of visual loss. The authors found the presumptive diagnosis of radiation-induced optic neuropathy facilitated by MR imaging with gadolinium-DTPA. This neuro-imaging procedure may help avert exploratory surgery in some patients with recurrent neoplasm in whom the etiology of visual loss is uncertain.

  11. Volumetric Diffuse Optical Tomography for Small Animals Using a CCD-Camera-Based Imaging System

    Directory of Open Access Journals (Sweden)

    Zi-Jing Lin

    2012-01-01

    Full Text Available We report the feasibility of three-dimensional (3D volumetric diffuse optical tomography for small animal imaging by using a CCD-camera-based imaging system with a newly developed depth compensation algorithm (DCA. Our computer simulations and laboratory phantom studies have demonstrated that the combination of a CCD camera and DCA can significantly improve the accuracy in depth localization and lead to reconstruction of 3D volumetric images. This approach may present great interests for noninvasive 3D localization of an anomaly hidden in tissue, such as a tumor or a stroke lesion, for preclinical small animal models.

  12. Functional imaging of small tissue volumes with diffuse optical tomography

    Science.gov (United States)

    Klose, Alexander D.; Hielscher, Andreas H.

    2006-03-01

    Imaging of dynamic changes in blood parameters, functional brain imaging, and tumor imaging are the most advanced application areas of diffuse optical tomography (DOT). When dealing with the image reconstruction problem one is faced with the fact that near-infrared photons, unlike X-rays, are highly scattered when they traverse biological tissue. Image reconstruction schemes are required that model the light propagation inside biological tissue and predict measurements on the tissue surface. By iteratively changing the tissue-parameters until the predictions agree with the real measurements, a spatial distribution of optical properties inside the tissue is found. The optical properties can be related to the tissue oxygenation, inflammation, or to the fluorophore concentration of a biochemical marker. If the model of light propagation is inaccurate, the reconstruction process will lead to an inaccurate result as well. Here, we focus on difficulties that are encountered when DOT is employed for functional imaging of small tissue volumes, for example, in cancer studies involving small animals, or human finger joints for early diagnosis of rheumatoid arthritis. Most of the currently employed image reconstruction methods rely on the diffusion theory that is an approximation to the equation of radiative transfer. But, in the cases of small tissue volumes and tissues that contain low scattering regions diffusion theory has been shown to be of limited applicability Therefore, we employ a light propagation model that is based on the equation of radiative transfer, which promises to overcome the limitations.

  13. Development of a Hybrid Nanoprobe for Triple-Modality MR/SPECT/Optical Fluorescence Imaging

    Science.gov (United States)

    Madru, Renata; Svenmarker, Pontus; Ingvar, Christian; Ståhlberg, Freddy; Engels, Stefan-Andersson; Knutsson, Linda; Strand, Sven-Erik

    2014-01-01

    Hybrid clinical imaging is an emerging technology, which improves disease diagnosis by combining already existing technologies. With the combination of high-resolution morphological imaging, i.e., MRI/CT, and high-sensitive molecular detection offered by SPECT/PET/Optical, physicians can detect disease progression at an early stage and design patient-specific treatments. To fully exploit the possibilities of hybrid imaging a hybrid probe compatible with each imaging technology is required. Here, we present a hybrid nanoprobe for triple modality MR/SPECT/Fluorescence imaging. Our imaging agent is comprised of superparamagnetic iron oxide nanoparticles (SPIONs), labeled with 99mTc and an Alexa fluorophore (AF), together forming 99mTc-AF-SPIONs. The agent was stable in human serum, and, after subcutaneous injection in the hind paw of Wistar rats, showed to be highly specific by accumulating in the sentinel lymph node. All three modalities clearly visualized the imaging agent. Our results show that a single imaging agent can be used for hybrid imaging. The use of a single hybrid contrast agent permits simultaneous hybrid imaging and, more conventionally, allow for single modality imaging at different time points. For example, a hybrid contrast agent enables pre-operative planning, intra-operative guidance, and post-operative evaluation with the same contrast agent. PMID:26852675

  14. High-speed optical frequency-domain imaging

    OpenAIRE

    Yun, S. H.; Tearney, G. J.; Boer; Iftimia, N. V.; Bouma, B. E.

    2003-01-01

    We demonstrate high-speed, high-sensitivity, high-resolution optical imaging based on optical frequency-domain interferometry using a rapidly-tuned wavelength-swept laser. We derive and show experimentally that frequency-domain ranging provides a superior signal-to-noise ratio compared with conventional time-domain ranging as used in optical coherence tomography. A high sensitivity of −110 dB was obtained with a 6 mW source at an axial resolution of 13.5 µm and an A-line rate of 15.7 kHz, rep...

  15. High-speed image matching with coaxial holographic optical correlator

    Science.gov (United States)

    Ikeda, Kanami; Watanabe, Eriko

    2016-09-01

    A computation speed of more than 100 Gbps is experimentally demonstrated using our developed ultrahigh-speed optical correlator. To verify this high computation speed practically, the computation speeds of our optical correlator and conventional digital image matching are quantitatively compared. We use a population count function that achieves the fastest calculation speed when calculating binary matching by a central processing unit (CPU). The calculation speed of the optical correlator is dramatically faster than that using a CPU (2.40 GHz × 4) and 16 GB of random access memory, especially when the calculation data are large-scale.

  16. Computational optical biomedical spectroscopy and imaging

    CERN Document Server

    Musa, Sarhan M

    2015-01-01

    Applications of Vibrational Spectroscopic Imaging in Personal Care Studies; Guojin Zhang, Roger L. McMullen, Richard Mendelsohn, and Osama M. MusaFluorescence Bioimaging with Applications to Chemistry; Ufana Riaz and S.M. AshrafNew Trends in Immunohistochemical, Genome, and Metabolomics Imaging; G. Livanos, Aditi Deshpande, C. Narayan, Ying Na, T. Quang, T. Farrahi, R. Koglin, Suman Shrestha, M. Zervakis, and George C. GiakosDeveloping a Comprehensive Taxonomy for Human Cell Types; Richard Conroy and Vinay PaiFunctional Near-Infrared S

  17. Mapping Winter Wheat with Multi-Temporal SAR and Optical Images in an Urban Agricultural Region

    Directory of Open Access Journals (Sweden)

    Tao Zhou

    2017-05-01

    Full Text Available Winter wheat is the second largest food crop in China. It is important to obtain reliable winter wheat acreage to guarantee the food security for the most populous country in the world. This paper focuses on assessing the feasibility of in-season winter wheat mapping and investigating potential classification improvement by using SAR (Synthetic Aperture Radar images, optical images, and the integration of both types of data in urban agricultural regions with complex planting structures in Southern China. Both SAR (Sentinel-1A and optical (Landsat-8 data were acquired, and classification using different combinations of Sentinel-1A-derived information and optical images was performed using a support vector machine (SVM and a random forest (RF method. The interference coherence and texture images were obtained and used to assess the effect of adding them to the backscatter intensity images on the classification accuracy. The results showed that the use of four Sentinel-1A images acquired before the jointing period of winter wheat can provide satisfactory winter wheat classification accuracy, with an F1 measure of 87.89%. The combination of SAR and optical images for winter wheat mapping achieved the best F1 measure–up to 98.06%. The SVM was superior to RF in terms of the overall accuracy and the kappa coefficient, and was faster than RF, while the RF classifier was slightly better than SVM in terms of the F1 measure. In addition, the classification accuracy can be effectively improved by adding the texture and coherence images to the backscatter intensity data.

  18. New approach to imaging spectroscopy using diffractive optics

    Science.gov (United States)

    Hinnrichs, Michele; Massie, Mark A.

    1997-10-01

    Over the past several years, Pacific Advanced Technology (PAT) has developed several hyperspectral imagers using diffractive optics as the dispersive media. This new approach has been patented and demonstrated in numerous field tests. PAT has developed hyperspectral cameras in the visible, mid-wave IR and is currently under contrast to the Air Force to develop a dual band hyperspectral lens for simultaneous spectral imaging in both the mid-wave and long- wave IR. The development of these cameras over the years have been sponsored by internal research and development, contracts from the Air Force Phillips Lab., Air Force Wright Labs Armament Division, BMDO and by the Office of Naval Research. Numerous papers have been presented in the past describing the performance of these various hyperspectral cameras. The purpose of this paper is to describe the theory behind the image multi-spectral sensing (IMSS) used in these hyperspectral cameras. IMSS utilizes a very simple optical design that enables a robust and low cost hyper-spectral imaging instrument. The IMSS is a dispersive spectrometer using a single diffractive optical element for both imaging and dispersion. The lens is tuned for a single wavelength giving maximum diffraction efficiency at that wavelength and high efficiency throughout the spectral band-pass of the camera. The diffractive optics disperse the light along the optical axis as opposed to perpendicular to the axis in conventional dispersive spectrometers. A detector array is used as the sensing medium and the spectral images are rad out electronically. POst processing is used to reduce spectral cross talk and to spatially sharpen the spectral images.

  19. Novel adaptive fiber-optics collimator for coherent beam combination.

    Science.gov (United States)

    Zhi, Dong; Ma, Pengfei; Ma, Yanxing; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2014-12-15

    In this manuscript, we experimentally validate a novel design of adaptive fiber-optics collimator (AFOC), which utilizes two levers to enlarge the movable range of the fiber end cap. The enlargement of the range makes the new AFOC possible to compensate the end-cap/tilt aberration in fiber laser beam combining system. The new AFOC based on flexible hinges and levers was fabricated and the performance of the new AFOC was tested carefully, including its control range, frequency response and control accuracy. Coherent beam combination (CBC) of two 5-W fiber amplifiers array with simultaneously end-cap/tilt control and phase-locking control was implemented successfully with the novel AFOC. Experimental results show that the average normalized power in the bucket (PIB) value increases from 0.311 to 0.934 with active phasing and tilt aberration compensation simultaneously, and with both controls on, the fringe contrast improves to more than 82% from 0% for the case with both control off. This work presents a promising structure for tilt aberration control in high power CBC system.

  20. A Combined Multiple-SLED Broadband Light Source at 1300 nm for High Resolution Optical Coherence Tomography.

    Science.gov (United States)

    Wang, Hui; Jenkins, Michael W; Rollins, Andrew M

    2008-04-01

    We demonstrate a compact, inexpensive, and reliable fiber-coupled light source with broad bandwidth and sufficient power at 1300 nm for high resolution optical coherence tomography (OCT) imaging in real-time applications. By combining four superluminescent diodes (SLEDs) with different central wavelengths, the light source has a bandwidth of 145 nm centered at 1325 nm with over 10 mW of power. OCT images of an excised stage 30 embryonic chick heart acquired with our combined SLED light source (<5 μm axial resolution in tissue) are compared with images obtained with a single SLED source (~10 μm axial resolution in tissue). The high resolution OCT system with the combined SLED light source provides better image quality (smaller speckle noise) and a greater ability to observe fine structures in the embryonic heart.

  1. A Combined Multiple-SLED Broadband Light Source at 1300 nm for High Resolution Optical Coherence Tomography

    Science.gov (United States)

    Wang, Hui; Jenkins, Michael W.; Rollins, Andrew M.

    2013-01-01

    We demonstrate a compact, inexpensive, and reliable fiber–coupled light source with broad bandwidth and sufficient power at 1300 nm for high resolution optical coherence tomography (OCT) imaging in real-time applications. By combining four superluminescent diodes (SLEDs) with different central wavelengths, the light source has a bandwidth of 145 nm centered at 1325 nm with over 10 mW of power. OCT images of an excised stage 30 embryonic chick heart acquired with our combined SLED light source (<5 μm axial resolution in tissue) are compared with images obtained with a single SLED source (~10 μm axial resolution in tissue). The high resolution OCT system with the combined SLED light source provides better image quality (smaller speckle noise) and a greater ability to observe fine structures in the embryonic heart. PMID:24347689

  2. The Subaru Deep Field: The Optical Imaging Data

    CERN Document Server

    Kashikawa, N; Yasuda, N; Ajiki, M; Akiyama, M; Ando, H; Aoki, K; Doi, M; Fujita, S S; Furusawa, H; Hayashino, T; Iwamuro, F; Iye, M; Karoji, H; Kobayashi, N; Kodaira, K; Kodama, T; Komiyama, Yu; Matsuda, Y; Miyazaki, S; Mizumoto, Y; Morokuma, T; Motohara, K; Murayama, T; Nagao, T; Nariai, K; Ohta, K; Okamura, S; Ouchi, M; Sasaki, T; Sato, Y; Sekiguchi, K; Shioya, Y; Tamura, H; Taniguchi, Y; Umemura, M; Yamada, T; Yoshida, M

    2004-01-01

    The Subaru Deep Field (SDF) project is a program of Subaru Observatory to carry out a deep galaxy survey over a blank field as large as 34'x27'. The program consists of very deep multi-band optical imaging, near infrared imaging for smaller portions of the field and follow-up optical spectroscopy. Major scientific goals of the project are to construct large samples of Lyman-break galaxies at z~4-5 and Lyman alpha emitters at z~5.7 and 6.6, and to make detailed studies these very high-redshift galaxy populations. In this paper, we describe the optical imaging observations and data reduction, presenting mosaicked images and object catalogs in seven bandpasses.The optical imaging was made through five broad-band filters, B, V, R, i', z', and two narrow-band filters, NB816 (lambda_c=8150A) and NB921 (lambda_c=9196A) with almost 10 hours long integrations for each band. The limiting magnitudes measured at 3-sigma on a 2" aperture are B=28.45, V=27.74, R=27.80, i'=27.43, z'=26.62, NB816=26.63, and NB921=26.54 in th...

  3. Optical fiber based imaging of bioengineered tissue construct

    Science.gov (United States)

    Sapoznik, Etai; Niu, Guoguang; Lu, Peng; Zhou, Yu; Xu, Yong; Soker, Shay

    2016-04-01

    Imaging cells and tissues through opaque and turbid media is challenging and presents a major barrier for monitoring maturation and remodeling of bioengineered tissues. The fiber optics based imaging system described here offers a new approach for fluorescent cell imaging. A micro imaging channel is embedded in a Polycaprolactone (PCL) electrospun scaffold designed for cell seeding, which allows us to use an optical fiber to locally deliver excitation laser close to the fluorescent cells. The emission is detected by an Electron Multiplying Charge Coupled Device (EMCCD) detector and image reconstruction of multiple excitation points is achieved with a working distance of several centimeters. The objective of this study is to assess the effects of system parameters on image reconstruction outcomes. Initial studies using fluorescent beads indicated that scaffold thickness had a small effect on image quality, whereas scaffold composition (collagen content), fluorophore spectra, and the reconstruction window size had a large effect. The results also suggest that a far-red fluorescent emission is preferential when using collagenous scaffolds with a thickness of up to 500 μm. Using these optimized parameters, we were able to image fluorescently labeled cells on a scaffold with a resolution of 15-20 μm, and have also measured muscle progenitor cell differentiation and scaffold surface coverage with endothelial cells. In the future, this imaging platform can be applied to other bioengineered tissues for non-invasive monitoring both in vitro and in vivo.

  4. The diffractive achromat full spectrum computational imaging with diffractive optics

    KAUST Repository

    Peng, Yifan

    2016-07-11

    Diffractive optical elements (DOEs) have recently drawn great attention in computational imaging because they can drastically reduce the size and weight of imaging devices compared to their refractive counterparts. However, the inherent strong dispersion is a tremendous obstacle that limits the use of DOEs in full spectrum imaging, causing unacceptable loss of color fidelity in the images. In particular, metamerism introduces a data dependency in the image blur, which has been neglected in computational imaging methods so far. We introduce both a diffractive achromat based on computational optimization, as well as a corresponding algorithm for correction of residual aberrations. Using this approach, we demonstrate high fidelity color diffractive-only imaging over the full visible spectrum. In the optical design, the height profile of a diffractive lens is optimized to balance the focusing contributions of different wavelengths for a specific focal length. The spectral point spread functions (PSFs) become nearly identical to each other, creating approximately spectrally invariant blur kernels. This property guarantees good color preservation in the captured image and facilitates the correction of residual aberrations in our fast two-step deconvolution without additional color priors. We demonstrate our design of diffractive achromat on a 0.5mm ultrathin substrate by photolithography techniques. Experimental results show that our achromatic diffractive lens produces high color fidelity and better image quality in the full visible spectrum. © 2016 ACM.

  5. Change detection in very high resolution multisensor optical images

    Science.gov (United States)

    Solano Correa, Yady T.; Bovolo, Francesca; Bruzzone, Lorenzo

    2014-10-01

    This work aims at developing an approach to the detection of changes in multisensor multitemporal VHR optical images. The main steps of the proposed method are: i) multisensor data homogenization; and ii) change detection in multisensor multitemporal VHR optical images. The proposed approach takes advantage of: the conversion to physical quantities suggested by Pacifici et. al.1 , the framework for the design of systems for change detection in VHR images presented by Bruzzone and Bovolo2 and the framework for unsupervised change detection presented by Bovolo and Bruzzone3. Multisensor data homogenization is achieved during pre-processing by taking into account differences in both radiometric and geometric dimensions. Whereas change detection was approached by extracting proper features from multisensor images such that they result to be comparable (at a given level of abstraction) even if extracted from images acquired by different sensors. In order to illustrate the results, a data set made up of a QuickBird and a WorldView-2 images - acquired in 2006 and 2010 respectively - over an area located in the Trentino region of Italy were used. However, the proposed approach is thought to be exportable to multitemporal images coming from passive sensors other than the two mentioned above. The experimental results obtained on the QuickBird and WorlView-2 image pair are accurate. Thus opening to further experiments on multitemporal images acquired by other sensors.

  6. GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and interferometric imaging

    CERN Document Server

    Blind, N; Gillessen, S; Kok, Y; Lippa, M; Perrin, G; Dembet, R; Fedou, P; Lacour, S; Perraut, K; Jocou, L; Burtscher, L; Hans, O; Haug, M; Haussmann, F; Huber, S; Janssen, A; Kellner, S; Ott, T; Pfuhl, O; Sturm, E; Weber, J; Wieprecht, E; Amorim, A; Brandner, W; Straubmeier, C

    2015-01-01

    GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imaging capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.

  7. Broadband Incoherent Imaging Using Multiple Aperture Optics

    Science.gov (United States)

    1989-12-01

    objects was by Galileo Galilei in the fall of 1609 (3:30). From that day on, the drive has been to improve upon the quality of the received image...increased diameter. (11:763) A second major drawback is the sheer weight of the mirror. Even Galileo realized that there is a limit to the size of a mirror

  8. Table-top diffuse optical imaging

    NARCIS (Netherlands)

    Sturgeon, K.A.; Bakker, L.P.

    2006-01-01

    This report describes the work done during a six months internshipat Philips Research for a Masters in Electronic and Electrical Engineering. An existing table-top tomography system for measuring lightin phantom breasts was restored. Updated software control and image reconstruction software was cr

  9. Table-top diffuse optical imaging

    NARCIS (Netherlands)

    Sturgeon, K.A.; Bakker, L.P.

    2006-01-01

    This report describes the work done during a six months internshipat Philips Research for a Masters in Electronic and Electrical Engineering. An existing table-top tomography system for measuring lightin phantom breasts was restored. Updated software control and image reconstruction software was cr

  10. A 3D integral imaging optical see-through head-mounted display.

    Science.gov (United States)

    Hua, Hong; Javidi, Bahram

    2014-06-02

    An optical see-through head-mounted display (OST-HMD), which enables optical superposition of digital information onto the direct view of the physical world and maintains see-through vision to the real world, is a vital component in an augmented reality (AR) system. A key limitation of the state-of-the-art OST-HMD technology is the well-known accommodation-convergence mismatch problem caused by the fact that the image source in most of the existing AR displays is a 2D flat surface located at a fixed distance from the eye. In this paper, we present an innovative approach to OST-HMD designs by combining the recent advancement of freeform optical technology and microscopic integral imaging (micro-InI) method. A micro-InI unit creates a 3D image source for HMD viewing optics, instead of a typical 2D display surface, by reconstructing a miniature 3D scene from a large number of perspective images of the scene. By taking advantage of the emerging freeform optical technology, our approach will result in compact, lightweight, goggle-style AR display that is potentially less vulnerable to the accommodation-convergence discrepancy problem and visual fatigue. A proof-of-concept prototype system is demonstrated, which offers a goggle-like compact form factor, non-obstructive see-through field of view, and true 3D virtual display.

  11. High-resolution in-depth imaging of optically cleared thick samples using an adaptive SPIM

    Science.gov (United States)

    Masson, Aurore; Escande, Paul; Frongia, Céline; Clouvel, Grégory; Ducommun, Bernard; Lorenzo, Corinne

    2015-11-01

    Today, Light Sheet Fluorescence Microscopy (LSFM) makes it possible to image fluorescent samples through depths of several hundreds of microns. However, LSFM also suffers from scattering, absorption and optical aberrations. Spatial variations in the refractive index inside the samples cause major changes to the light path resulting in loss of signal and contrast in the deepest regions, thus impairing in-depth imaging capability. These effects are particularly marked when inhomogeneous, complex biological samples are under study. Recently, chemical treatments have been developed to render a sample transparent by homogenizing its refractive index (RI), consequently enabling a reduction of scattering phenomena and a simplification of optical aberration patterns. One drawback of these methods is that the resulting RI of cleared samples does not match the working RI medium generally used for LSFM lenses. This RI mismatch leads to the presence of low-order aberrations and therefore to a significant degradation of image quality. In this paper, we introduce an original optical-chemical combined method based on an adaptive SPIM and a water-based clearing protocol enabling compensation for aberrations arising from RI mismatches induced by optical clearing methods and acquisition of high-resolution in-depth images of optically cleared complex thick samples such as Multi-Cellular Tumour Spheroids.

  12. Image processing based automatic diagnosis of glaucoma using wavelet features of segmented optic disc from fundus image.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore; ParthaSarathi, M; Uher, Vaclav; Burget, Radim

    2016-02-01

    Glaucoma is a disease of the retina which is one of the most common causes of permanent blindness worldwide. This paper presents an automatic image processing based method for glaucoma diagnosis from the digital fundus image. In this paper wavelet feature extraction has been followed by optimized genetic feature selection combined with several learning algorithms and various parameter settings. Unlike the existing research works where the features are considered from the complete fundus or a sub image of the fundus, this work is based on feature extraction from the segmented and blood vessel removed optic disc to improve the accuracy of identification. The experimental results presented in this paper indicate that the wavelet features of the segmented optic disc image are clinically more significant in comparison to features of the whole or sub fundus image in the detection of glaucoma from fundus image. Accuracy of glaucoma identification achieved in this work is 94.7% and a comparison with existing methods of glaucoma detection from fundus image indicates that the proposed approach has improved accuracy of classification.

  13. Optical imaging of individual biomolecules in densely packed clusters

    Science.gov (United States)

    Dai, Mingjie; Jungmann, Ralf; Yin, Peng

    2016-09-01

    Recent advances in fluorescence super-resolution microscopy have allowed subcellular features and synthetic nanostructures down to 10-20 nm in size to be imaged. However, the direct optical observation of individual molecular targets (∼5 nm) in a densely packed biomolecular cluster remains a challenge. Here, we show that such discrete molecular imaging is possible using DNA-PAINT (points accumulation for imaging in nanoscale topography)—a super-resolution fluorescence microscopy technique that exploits programmable transient oligonucleotide hybridization—on synthetic DNA nanostructures. We examined the effects of a high photon count, high blinking statistics and an appropriate blinking duty cycle on imaging quality, and developed a software-based drift correction method that achieves optical nanodisplay with 5 × 5 nm pixel size and three distinct colours with <1 nm cross-channel registration accuracy.

  14. Biologically relevant photoacoustic imaging phantoms with tunable optical and acoustic properties

    Science.gov (United States)

    Vogt, William C.; Jia, Congxian; Wear, Keith A.; Garra, Brian S.; Joshua Pfefer, T.

    2016-10-01

    Established medical imaging technologies such as magnetic resonance imaging and computed tomography rely on well-validated tissue-simulating phantoms for standardized testing of device image quality. The availability of high-quality phantoms for optical-acoustic diagnostics such as photoacoustic tomography (PAT) will facilitate standardization and clinical translation of these emerging approaches. Materials used in prior PAT phantoms do not provide a suitable combination of long-term stability and realistic acoustic and optical properties. Therefore, we have investigated the use of custom polyvinyl chloride plastisol (PVCP) formulations for imaging phantoms and identified a dual-plasticizer approach that provides biologically relevant ranges of relevant properties. Speed of sound and acoustic attenuation were determined over a frequency range of 4 to 9 MHz and optical absorption and scattering over a wavelength range of 400 to 1100 nm. We present characterization of several PVCP formulations, including one designed to mimic breast tissue. This material is used to construct a phantom comprised of an array of cylindrical, hemoglobin-filled inclusions for evaluation of penetration depth. Measurements with a custom near-infrared PAT imager provide quantitative and qualitative comparisons of phantom and tissue images. Results indicate that our PVCP material is uniquely suitable for PAT system image quality evaluation and may provide a practical tool for device validation and intercomparison.

  15. Closed-loop optical stabilization and digital image registration in adaptive optics scanning light ophthalmoscopy.

    Science.gov (United States)

    Yang, Qiang; Zhang, Jie; Nozato, Koji; Saito, Kenichi; Williams, David R; Roorda, Austin; Rossi, Ethan A

    2014-09-01

    Eye motion is a major impediment to the efficient acquisition of high resolution retinal images with the adaptive optics (AO) scanning light ophthalmoscope (AOSLO). Here we demonstrate a solution to this problem by implementing both optical stabilization and digital image registration in an AOSLO. We replaced the slow scanning mirror with a two-axis tip/tilt mirror for the dual functions of slow scanning and optical stabilization. Closed-loop optical stabilization reduced the amplitude of eye-movement related-image motion by a factor of 10-15. The residual RMS error after optical stabilization alone was on the order of the size of foveal cones: ~1.66-2.56 μm or ~0.34-0.53 arcmin with typical fixational eye motion for normal observers. The full implementation, with real-time digital image registration, corrected the residual eye motion after optical stabilization with an accuracy of ~0.20-0.25 μm or ~0.04-0.05 arcmin RMS, which to our knowledge is more accurate than any method previously reported.

  16. Optical drug monitoring: photoacoustic imaging of nanosensors to monitor therapeutic lithium in vivo.

    Science.gov (United States)

    Cash, Kevin J; Li, Chiye; Xia, Jun; Wang, Lihong V; Clark, Heather A

    2015-02-24

    Personalized medicine could revolutionize how primary care physicians treat chronic disease and how researchers study fundamental biological questions. To realize this goal, we need to develop more robust, modular tools and imaging approaches for in vivo monitoring of analytes. In this report, we demonstrate that synthetic nanosensors can measure physiologic parameters with photoacoustic contrast, and we apply that platform to continuously track lithium levels in vivo. Photoacoustic imaging achieves imaging depths that are unattainable with fluorescence or multiphoton microscopy. We validated the photoacoustic results that illustrate the superior imaging depth and quality of photoacoustic imaging with optical measurements. This powerful combination of techniques will unlock the ability to measure analyte changes in deep tissue and will open up photoacoustic imaging as a diagnostic tool for continuous physiological tracking of a wide range of analytes.

  17. Optimization of Bit Plane Combination for Efficient Digital Image Watermarking

    CERN Document Server

    Kejgir, Sushma

    2009-01-01

    In view of the frequent multimedia data transfer authentication and protection of images has gained importance in todays world. In this paper we propose a new watermarking technique, based on bit plane, which enhances robustness and capacity of the watermark, as well as maintains transparency of the watermark and fidelity of the image. In the proposed technique, higher strength bit plane of digital signature watermark is embedded in to a significant bit plane of the original image. The combination of bit planes (image and watermark) selection is an important issue. Therefore, a mechanism is developed for appropriate bit plane selection. Ten different attacks are selected to test different alternatives. These attacks are given different weightings as appropriate to user requirement. A weighted correlation coefficient for retrieved watermark is estimated for each of the alternatives. Based on these estimated values optimal bit plane combination is identified for a given user requirement. The proposed method is ...

  18. Automated Localization of Optic Disc in Retinal Images

    Directory of Open Access Journals (Sweden)

    Deepali A.Godse

    2013-03-01

    Full Text Available An efficient detection of optic disc (OD in colour retinal images is a significant task in an automated retinal image analysis system. Most of the algorithms developed for OD detection are especially applicable to normal and healthy retinal images. It is a challenging task to detect OD in all types of retinal images, that is, normal, healthy images as well as abnormal, that is, images affected due to disease. This paper presents an automated system to locate an OD and its centre in all types of retinal images. The ensemble of steps based on different criteria produces more accurate results. The proposed algorithm gives excellent results and avoids false OD detection. The technique is developed and tested on standard databases provided for researchers on internet, Diaretdb0 (130 images, Diaretdb1 (89 images, Drive (40 images and local database (194 images. The local database images are collected from ophthalmic clinics. It is able to locate OD and its centre in 98.45% of all tested cases. The results achieved by different algorithms can be compared when algorithms are applied on same standard databases. This comparison is also discussed in this paper which shows that the proposed algorithm is more efficient.

  19. Optical coherence tomography-based micro-particle image velocimetry.

    Science.gov (United States)

    Mujat, Mircea; Ferguson, R Daniel; Iftimia, Nicusor; Hammer, Daniel X; Nedyalkov, Ivaylo; Wosnik, Martin; Legner, Hartmut

    2013-11-15

    We present a new application of optical coherence tomography (OCT), widely used in biomedical imaging, to flow analysis in near-wall hydrodynamics for marine research. This unique capability, called OCT micro-particle image velocimetry, provides a high-resolution view of microscopic flow phenomena and measurement of flow statistics within the first millimeter of a boundary layer. The technique is demonstrated in a small flow cuvette and in a water tunnel.

  20. Cytology 3D structure formation based on optical microscopy images

    Science.gov (United States)

    Pronichev, A. N.; Polyakov, E. V.; Shabalova, I. P.; Djangirova, T. V.; Zaitsev, S. M.

    2017-01-01

    The article the article is devoted to optimization of the parameters of imaging of biological preparations in optical microscopy using a multispectral camera in visible range of electromagnetic radiation. A model for the image forming of virtual preparations was proposed. The optimum number of layers was determined for the object scan in depth and holistic perception of its switching according to the results of the experiment.

  1. Stable phantom materials for ultrasound and optical imaging

    Science.gov (United States)

    Cabrelli, Luciana C.; Pelissari, Pedro I. B. G. B.; Deana, Alessandro M.; Carneiro, Antonio A. O.; Pavan, Theo Z.

    2017-01-01

    Phantoms mimicking the specific properties of biological tissues are essential to fully characterize medical devices. Water-based materials are commonly used to manufacture phantoms for ultrasound and optical imaging techniques. However, these materials have disadvantages, such as easy degradation and low temporal stability. In this study, we propose an oil-based new tissue-mimicking material for ultrasound and optical imaging, with the advantage of presenting low temporal degradation. A styrene-ethylene/butylene-styrene (SEBS) copolymer in mineral oil samples was made varying the SEBS concentration between 5%-15%, and low-density polyethylene (LDPE) between 0%-9%. Acoustic properties, such as the speed of sound and the attenuation coefficient, were obtained using frequencies ranging from 1-10 MHz, and were consistent with that of soft tissues. These properties were controlled varying SEBS and LDPE concentration. To characterize the optical properties of the samples, the diffuse reflectance and transmittance were measured. Scattering and absorption coefficients ranging from 400 nm-1200 nm were calculated for each compound. SEBS gels are a translucent material presenting low optical absorption and scattering coefficients in the visible region of the spectrum, but the presence of LDPE increased the turbidity. Adding LDPE increased the absorption and scattering of the phantom materials. Ultrasound and photoacoustic images of a heterogeneous phantom made of LDPE/SEBS containing a spherical inclusion were obtained. Annatto dye was added to the inclusion to enhance the optical absorbance. The results suggest that copolymer gels are promising for ultrasound and optical imaging, making them also potentially useful for photoacoustic imaging.

  2. Optical Picosecond MCPI-Based Imagers

    Energy Technology Data Exchange (ETDEWEB)

    Buckles, R. A.; guyton, R. L.; Ross, P. W.

    2012-08-14

    We report on the design, construction, and initial test results of a custom MCPI design which incorporates a wideband strip transmission line drive structure. A special 16:1 series transmission-line-transformer (STLT) is utilized to distribute the drive signal from a 50-ohm, 1.85 mm coaxial vacuum feedthrough to a 3-ohm strip across the MCP. Transformer circuit material is a flexible Teflon/Kapton laminate for minimal loss and dispersion. A novel vialess multilayer structure composed of embedded, symmetrical strips, preserves ideal impulse response. Impedance matched interfaces and transitions are designed with method of moments, empirical codes, and finite element analysis. Millimeter-wave time-domain reflectometer and vector network analyzer measurements are presented, with comparison to time-domain and swept frequency 3D finite element simulation. Gain compression is expected to produce a 20 ps optical impulse response, dominated by the leaded MCP glass dielectric dispersion. Follow-on work will complete the optical impulse response tests, and extrapolation to more expensive silicon MCP and 1-mm feedthroughs promises an impulse response of 5 ps.

  3. The optics of microscope image formation.

    Science.gov (United States)

    Wolf, David E

    2013-01-01

    Although geometric optics gives a good understanding of how the microscope works, it fails in one critical area, which is explaining the origin of microscope resolution. To accomplish this, one must consider the microscope from the viewpoint of physical optics. This chapter describes the theory of the microscope-relating resolution to the highest spatial frequency that a microscope can collect. The chapter illustrates how Huygens' principle or construction can be used to explain the propagation of a plane wave. It is shown that this limit increases with increasing numerical aperture (NA). As a corollary to this, resolution increases with decreasing wavelength because of how NA depends on wavelength. The resolution is higher for blue light than red light. Resolution is dependent on contrast, and the higher the contrast, the higher the resolution. This last point relates to issues of signal-to-noise and dynamic range. The use of video and new digital cameras has necessitated redefining classical limits such as those of Rayleigh's criterion. Copyright © 2007 Elsevier Inc. All rights reserved.

  4. Simultaneous morphological and biochemical endogenous optical imaging of atherosclerosis.

    Science.gov (United States)

    Jo, Javier A; Park, Jesung; Pande, Paritosh; Shrestha, Sebina; Serafino, Michael J; Rico Jimenez, J de Jesus; Clubb, Fred; Walton, Brian; Buja, L Maximilian; Phipps, Jennifer E; Feldman, Marc D; Adame, Jessie; Applegate, Brian E

    2015-08-01

    The aim of this study was to validate novel imaging technology for simultaneous morphological and biochemical endogenous optical imaging of coronary atherosclerotic plaque. Optical coherence tomography (OCT) generates high-resolution 3D images of plaque morphology and endogenous fluorescence lifetime imaging microscopy (FLIM) characterizes biochemical composition. Both imaging modalities rely on plaque's intrinsic optical characteristics, making contrast agents unnecessary. A multimodal OCT/FLIM system was utilized to generate luminal biochemical maps superimposed on high-resolution (7 µm axial and 13 µm lateral) structural volumetric images. Forty-seven fresh postmortem human coronary segments were imaged: pathological intimal thickening (PIT, n = 26), fibroatheroma (FA, n = 12), thin-cap FA (TCFA, n = 2), and fibrocalcific plaque (CA, n = 7), determined by histopathology. Multimodal images were evaluated, and each plaque identified as PIT, FA, TCFA, or CA based on expert OCT readers, and as having high-lipid (HL), high-collagen (HC), or low-collagen/low-lipid (LCL) luminal composition based on linear discriminant analysis of FLIM. Of 47 plaques, 89.4% (42/47) of the plaques were correctly identified based on OCT/FLIM evaluation using tissue histopathology and immunohistochemistry as the gold standard. Four of the misclassifications corresponded to confusing PIT with HL luminal composition for FA with HL cap. The other corresponded to confusing FA with a HC cap for FA with an LCL cap. We have demonstrated the feasibility of accurate simultaneous OCT/FLIM morphological and biochemical characterization of coronary plaques at spatial resolutions and acquisition speeds compatible with catheter-based intravascular imaging. The success of this pilot study sets up future development of a multimodal intravascular imaging system that will enable studies that could help improve our understanding of plaque pathogenesis. Published on behalf of the European Society of

  5. Positioning sensor by combining optical projection and photogrammetry

    Science.gov (United States)

    Zheng, Benrui

    Six spatial parameters, (x, y, z) for translation, and pitch, roll, and yaw for rotation, are used to describe the 3-dimensional position and orientation of a rigid body---the 6 degrees of freedom (DOF). The ability to measure these parameters is required in a diverse range of applications including machine tool metrology, robot calibration, motion control, motion analysis, and reconstructive surgery. However, there are limitations associated with the currently available measurement systems. Shortcomings include some of the following: short dynamic range, limited accuracy, line of sight restrictions, and capital cost. The objective of this dissertation was to develop a new metrology system that overcomes line of sight restrictions, reduces system costs, allows large dynamic range and has the potential to provide high measurement accuracy. The new metrology system proposed in this dissertation is based on a combination of photogrammetry and optical pattern projection. This system has the potential to enable real-time measurement of a small lightweight module's location. The module generates an optical pattern that is observable on the surrounding walls, and photogrammetry is used to measure the absolute coordinates of features in the projected optical pattern with respect to a defined global coordinate system. By combining these absolute coordinates with the known angular information of the optical projection beams, a minimization algorithm can be used to extract the absolute coordinates and angular orientation of the module itself. The feasibility of the proposed metrology system was first proved through preliminary experimental tests. By using a module with a 7x7 dot matrix pattern, experimental agreement of 1 to 5 parts in 103 was obtained by translating the module over 0.9 m and by rotating it through 60°. The proposed metrology system was modeled through numerical simulations and factors affecting the uncertainty of the measurement were investigated. The

  6. Glaucoma severity affects diffusion tensor imaging (DTI) parameters of the optic nerve and optic radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sidek, S. [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia); Medical Imaging Unit, Faculty of Medicine, Universiti Teknologi MARA, Selangor (Malaysia); Ramli, N. [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia); Rahmat, K., E-mail: katt_xr2000@yahoo.com [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia); Ramli, N.M.; Abdulrahman, F. [Department of Ophthalmology, Faculty of Medicine, University Malaya, Kuala Lumpur (Malaysia); Tan, L.K. [Department of Biomedical Imaging, University Malaya, Research Imaging Centre, Faculty of Medicine, University Malaya (Malaysia)

    2014-08-15

    Objectives: To evaluate whether MR diffusion tensor imaging (DTI) of the optic nerve and optic radiation in glaucoma patients provides parameters to discriminate between mild and severe glaucoma and to determine whether DTI derived indices correlate with retinal nerve fibre layer (RNFL) thickness. Methods: 3-Tesla DTI was performed on 90 subjects (30 normal, 30 mild glaucoma and 30 severe glaucoma subjects) and the FA and MD of the optic nerve and optic radiation were measured. The categorisation into mild and severe glaucoma was done using the Hodapp–Parrish–Anderson (HPA) classification. RNFL thickness was also assessed on all subjects using OCT. Receiver operating characteristic (ROC) analysis and Spearman's correlation coefficient was carried out. Results: FA and MD values in the optic nerve and optic radiation decreased and increased respectively as the disease progressed. FA at the optic nerve had the highest sensitivity (87%) and specificity (80%). FA values displayed the strongest correlation with RNFL thickness in the optic nerve (r = 0.684, p ≤ 0.001) while MD at the optic radiation showed the weakest correlation with RNFL thickness (r = −0.360, p ≤ 0.001). Conclusions: The high sensitivity and specificity of DTI-derived FA values in the optic nerve and the strong correlation between DTI-FA and RNFL thickness suggest that these parameters could serve as indicators of disease severity.

  7. Multimodal photoacoustic and optical coherence tomography scanner using an all optical detection scheme for 3D morphological skin imaging.

    Science.gov (United States)

    Zhang, Edward Z; Povazay, Boris; Laufer, Jan; Alex, Aneesh; Hofer, Bernd; Pedley, Barbara; Glittenberg, Carl; Treeby, Bradley; Cox, Ben; Beard, Paul; Drexler, Wolfgang

    2011-08-01

    A noninvasive, multimodal photoacoustic and optical coherence tomography (PAT/OCT) scanner for three-dimensional in vivo (3D) skin imaging is described. The system employs an integrated, all optical detection scheme for both modalities in backward mode utilizing a shared 2D optical scanner with a field-of-view of ~13 × 13 mm(2). The photoacoustic waves were detected using a Fabry Perot polymer film ultrasound sensor placed on the surface of the skin. The sensor is transparent in the spectral range 590-1200 nm. This permits the photoacoustic excitation beam (670-680 nm) and the OCT probe beam (1050 nm) to be transmitted through the sensor head and into the underlying tissue thus providing a backward mode imaging configuration. The respective OCT and PAT axial resolutions were 8 and 20 µm and the lateral resolutions were 18 and 50-100 µm. The system provides greater penetration depth than previous combined PA/OCT devices due to the longer wavelength of the OCT beam (1050 nm rather than 829-870 nm) and by operating in the tomographic rather than the optical resolution mode of photoacoustic imaging. Three-dimensional in vivo images of the vasculature and the surrounding tissue micro-morphology in murine and human skin were acquired. These studies demonstrated the complementary contrast and tissue information provided by each modality for high-resolution 3D imaging of vascular structures to depths of up to 5 mm. Potential applications include characterizing skin conditions such as tumors, vascular lesions, soft tissue damage such as burns and wounds, inflammatory conditions such as dermatitis and other superficial tissue abnormalities.

  8. Optical Doppler tomography and spectral Doppler imaging of localized ischemic stroke in a mouse model

    Science.gov (United States)

    Yu, Lingfeng; Nguyen, Elaine; Liu, Gangjun; Rao, Bin; Choi, Bernard; Chen, Zhongping

    2010-02-01

    We present a combined optical Doppler tomography/spectral Doppler imaging modality to quantitatively evaluate the dynamic blood circulation and the artery blockage before and after a localized ischemic stroke in a mouse model. Optical Doppler Tomography (ODT) combines the Doppler principle with optical coherence tomography for noninvasive localization and measurement of particle flow velocity in highly scattering media with micrometer scale spatial resolution. Spectral Doppler imaging (SDI) provides complementary temporal flow information to the spatially distributed flow information of Doppler imaging. Fast, repeated, ODT scans across an entire vessel were performed to record flow dynamic information with high temporal resolution of cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time for scatters within the imaging volume using spectral Doppler waveforms. Furthermore, vascular conditions can be quantified with various Doppler-angle-independent flow indices. Non-invasive in-vivo mice experiments were performed to evaluate microvascular blood circulation of a localized ischemic stroke mouse model.

  9. Functional Doppler optical coherence tomography for cortical blood flow imaging

    Science.gov (United States)

    Yu, Lingfeng; Liu, Gangjun; Nguyen, Elaine; Choi, Bernard; Chen, Zhongping

    2010-02-01

    Optical methods have been widely used in basic neuroscience research to study the cerebral blood flow dynamics in order to overcome the low spatial resolution associated with magnetic resonance imaging and positron emission tomography. Although laser Doppler imaging and laser speckle imaging can map out en face cortical hemodynamics and columns, depth resolution is not available. Two-photon microscopy has been used for mapping cortical activity. However, flow measurement requires fluorescent dye injection, which can be problematic. The noninvasive and high resolution tomographic capabilities of optical coherence tomography make it a promising technique for mapping depth resolved cortical blood flow. Here, we present a functional Doppler optical coherence tomography (OCT) imaging modality for quantitative evaluation of cortical blood flow in a mouse model. Fast, repeated, Doppler OCT scans across a vessel of interest were performed to record flow dynamic information with a high temporal resolution of the cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time, thereby providing complementary temporal flow information to the spatially distributed flow information of Doppler OCT. The proposed functional Doppler OCT imaging modality can be used to diagnose vessel stenosis/blockage or monitor blood flow changes due to pharmacological agents/neuronal activities. Non-invasive in-vivo mice experiments were performed to verify the capabilities of function Doppler OCT.

  10. Adapting smartphones for low-cost optical medical imaging

    Science.gov (United States)

    Pratavieira, Sebastião.; Vollet-Filho, José D.; Carbinatto, Fernanda M.; Blanco, Kate; Inada, Natalia M.; Bagnato, Vanderlei S.; Kurachi, Cristina

    2015-06-01

    Optical images have been used in several medical situations to improve diagnosis of lesions or to monitor treatments. However, most systems employ expensive scientific (CCD or CMOS) cameras and need computers to display and save the images, usually resulting in a high final cost for the system. Additionally, this sort of apparatus operation usually becomes more complex, requiring more and more specialized technical knowledge from the operator. Currently, the number of people using smartphone-like devices with built-in high quality cameras is increasing, which might allow using such devices as an efficient, lower cost, portable imaging system for medical applications. Thus, we aim to develop methods of adaptation of those devices to optical medical imaging techniques, such as fluorescence. Particularly, smartphones covers were adapted to connect a smartphone-like device to widefield fluorescence imaging systems. These systems were used to detect lesions in different tissues, such as cervix and mouth/throat mucosa, and to monitor ALA-induced protoporphyrin-IX formation for photodynamic treatment of Cervical Intraepithelial Neoplasia. This approach may contribute significantly to low-cost, portable and simple clinical optical imaging collection.

  11. Establishing Information Security Systems via Optical Imaging

    Science.gov (United States)

    2015-08-11

    Laser Object Computer Fig. 5. A schematic setup for the proposed method using holography: BSC, Beam splitter cube; CCD, Charge-coupled device. The...SLM Object~~~, ........ . . . . . . . . . . . . . . . . . Laser CCD DJ Fig. 9. A schematic for computational ghost imaging: BD, bucket detector...polarization. (c) Since the sophisticated optoelectronic devices and systems should be analyzed before the retrieval, any hostile hacker will need to

  12. 4F-based optical phase imaging system

    DEFF Research Database (Denmark)

    2013-01-01

    The invention relates to 4F-based optical phase imaging system and in particular to reconstructing quantitative phase information of an object when using such systems. The invention applies a two-dimensional, complex spatial light modulator (SLM) to impress a complex spatial synthesized modulation...... in addition to the complex spatial modulation impressed by the object. This SLM is arranged so that the synthesized modulation is superimposed with the object modulation and is thus placed at an input plane to the phase imaging system. By evaluating output images from the phase imaging system, the synthesized...... modulation is selected to optimize parameters in the output image which improves the reconstruction of qualitative and quantitative object phase information from the resulting output images....

  13. Optical and Functional Imaging in Lung Cancer

    NARCIS (Netherlands)

    K.H. van der Leest (Cor)

    2010-01-01

    textabstractLung cancer is the second most common cancer in men and women, and is the leading cause of cancer related death. In industrialized countries the mortality rate of lung cancer is higher than the mortality rate of breast, colorectal and prostate cancer combined 1. When lung cancer is diagn

  14. Optical and Functional Imaging in Lung Cancer

    NARCIS (Netherlands)

    K.H. van der Leest (Cor)

    2010-01-01

    textabstractLung cancer is the second most common cancer in men and women, and is the leading cause of cancer related death. In industrialized countries the mortality rate of lung cancer is higher than the mortality rate of breast, colorectal and prostate cancer combined 1. When lung cancer is diagn

  15. Magnetic resonance imaging in optic nerve lesions with multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Shigeyuki; Hirayama, Keizo; Kakisu, Yonetsugu; Adachi, Emiko (Chiba Univ. (Japan). School of Medicine)

    1990-12-01

    Magnetic resonance imaging (MRI) of the optic nerve was performed in 10 patients with multiple sclerosis (MS) using short inversion time inversion recovery (STIR) pulse sequences, and the results were compared with the visual evoked potentials (VEP). The 10 patients had optic neuritis in the chronic or remitting phase together with additional symptoms or signs allowing a diagnosis of clinically definite or probable MS. Sixteen optic nerves were clinically affected and 4 were unaffected. MRI was performed using a 0.5 tesla supeconducting unit, and multiple continuous 5 mm coronal and axial STIR images were obtained. A lesion was judged to be present if a focal or diffuse area of increased signal intensity was detectd in the optic nerve. In VEP, a delay in peak latency or no P 100 component was judged to be abnormal. With regard to the clinically affected optic nerves, MRI revealed a region of increased signal intensity in 14/16 (88%) and the VEP was abnormal in 16/16 (100%). In the clinically unaffected optic nerves, MRI revealed an increased signal intensity in 2/4 (50%). One of these nerves had an abnormal VEP and the other had a VEP latency at the upper limit of normal. The VEP was abnormal in 1/4 (25%). In the clinically affected optic nerves, the degree of loss of visual acuity was not associated with the longitudinal extent of the lesions shown by MRI. The mean length was 17.5 mm in optic nerves with a slight disturbance of visual acuity and 15.0 mm in nerves with severe visual loss. MRI using STIR pulse sequences was found to be almost as sensitive as VEP in detecting both clinically affected and unaffected optic nerve lesions in patients with MS, and was useful in visualizing the location or size of the lesions. (author).

  16. CHOROIDAL IMAGING USING SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY

    Science.gov (United States)

    Regatieri, Caio V.; Branchini, Lauren; Fujimoto, James G.; Duker, Jay S.

    2012-01-01

    Background A structurally and functionally normal choroidal vasculature is essential for retinal function. Therefore, a precise clinical understanding of choroidal morphology should be important for understanding many retinal and choroidal diseases. Methods PUBMED (http://www.ncbi.nlm.nih.gov/sites/entrez?db=pubmed) was used for most of the literature search for this article. The criterion for inclusion of an article in the references for this review was that it included materials about both the clinical and the basic properties of choroidal imaging using spectral-domain optical coherence tomography. Results Recent reports show successful examination and accurate measurement of choroidal thickness in normal and pathologic states using spectral-domain optical coherence tomography systems. This review focuses on the principles of the new technology that make choroidal imaging using optical coherence tomography possible and on the changes that subsequently have been documented to occur in the choroid in various diseases. Additionally, it outlines future directions in choroidal imaging. Conclusion Optical coherence tomography is now proven to be an effective noninvasive tool to evaluate the choroid and to detect choroidal changes in pathologic states. Additionally, choroidal evaluation using optical coherence tomography can be used as a parameter for diagnosis and follow-up. PMID:22487582

  17. Optical synchrotron radiation beam imaging with a digital mask

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [Univ. of Maryland, College Park, MD (United States); Fiorito, Ralph [Univ. of Maryland, College Park, MD (United States); Corbett, Jeff [SLAC National Accelerator Lab., Menlo Park, CA (United States); Shkvarunets, Anatoly [Univ. of Maryland, College Park, MD (United States); Tian, Kai [SLAC National Accelerator Lab., Menlo Park, CA (United States); Fisher, Alan [SLAC National Accelerator Lab., Menlo Park, CA (United States); Douglas, D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wilson, F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Mok, W. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Mitsuhashi, T. [KEK, Tsukuba (Japan)

    2016-01-01

    The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500mA circulating in the storage ring (equivalently 392nC). Each injection pulse contains only 40-80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during User operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by re-imaging visible synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera makes it is possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

  18. Endocular ophthalmoscope: miniaturization and optical imaging quality

    Science.gov (United States)

    Rol, Pascal O.; Beck, Dominik; Niederer, Peter F.

    1991-06-01

    Endoscopy is a novel method of observation in ocular surgery. It allows a direct viewing of certain internal structures of the eye which can not be seen through conventional slit lamp/microscope arrangements like the back side of the iris, the posterior chamber or the fixation area of an IOL. In addition such an instrument is useful in exploratory orbital surgery because it allows for examination of the scleral wall, the 6 motor muscles and the optic nerve sheet with minimal trauma to the eye. An endoscopic system can therefore be helpful to check regions which can not be reached easily during surgery, such as the ciliary body or the pars plana. When a transparent structure of the eye becomes turbid, e.g., a hazy cornea, observation is impaired and endoscopy could also provide a solution though it is an invasive method.

  19. eXtreme Adaptive Optics Planet Imager: overview and status

    Science.gov (United States)

    Macintosh, Bruce A.; Bauman, Brian; Wilhelmsen Evans, Julia; Graham, James R.; Lockwood, Christopher; Poyneer, Lisa; Dillon, Daren; Gavel, Don T.; Green, Joseph J.; Lloyd, James P.; Makidon, Russell B.; Olivier, Scot; Palmer, Dave; Perrin, Marshall D.; Severson, Scott; Sheinis, Andrew I.; Sivaramakrishnan, Anand; Sommargren, Gary; Soummer, Remi; Troy, Mitchell; Wallace, J. Kent; Wishnow, Edward

    2004-10-01

    As adaptive optics (AO) matures, it becomes possible to envision AO systems oriented towards specific important scientific goals rather than general-purpose systems. One such goal for the next decade is the direct imaging detection of extrasolar planets. An "extreme" adaptive optics (ExAO) system optimized for extrasolar planet detection will have very high actuator counts and rapid update rates - designed for observations of bright stars - and will require exquisite internal calibration at the nanometer level. In addition to extrasolar planet detection, such a system will be capable of characterizing dust disks around young or mature stars, outflows from evolved stars, and high Strehl ratio imaging even at visible wavelengths. The NSF Center for Adaptive Optics has carried out a detailed conceptual design study for such an instrument, dubbed the eXtreme Adaptive Optics Planet Imager or XAOPI. XAOPI is a 4096-actuator AO system, notionally for the Keck telescope, capable of achieving contrast ratios >107 at angular separations of 0.2-1". ExAO system performance analysis is quite different than conventional AO systems - the spatial and temporal frequency content of wavefront error sources is as critical as their magnitude. We present here an overview of the XAOPI project, and an error budget highlighting the key areas determining achievable contrast. The most challenging requirement is for residual static errors to be less than 2 nm over the controlled range of spatial frequencies. If this can be achieved, direct imaging of extrasolar planets will be feasible within this decade.

  20. Optical design of microlens array for CMOS image sensors

    Science.gov (United States)

    Zhang, Rongzhu; Lai, Liping

    2016-10-01

    The optical crosstalk between the pixel units can influence the image quality of CMOS image sensor. In the meantime, the duty ratio of CMOS is low because of its pixel structure. These two factors cause the low detection sensitivity of CMOS. In order to reduce the optical crosstalk and improve the fill factor of CMOS image sensor, a microlens array has been designed and integrated with CMOS. The initial parameters of the microlens array have been calculated according to the structure of a CMOS. Then the parameters have been optimized by using ZEMAX and the microlens arrays with different substrate thicknesses have been compared. The results show that in order to obtain the best imaging quality, when the effect of optical crosstalk for CMOS is the minimum, the best distance between microlens array and CMOS is about 19.3 μm. When incident light successively passes through microlens array and the distance, obtaining the minimum facula is around 0.347 um in the active area. In addition, when the incident angle of the light is 0o 22o, the microlens array has obvious inhibitory effect on the optical crosstalk. And the anti-crosstalk distance between microlens array and CMOS is 0 μm 162 μm.

  1. Visible-Light Tomography Using an Optical Imaging-System

    NARCIS (Netherlands)

    Ingesson, L. C.; Koning, J. J.; Donne, A. J. H.; D.C. Schram,

    1992-01-01

    A system for tomography in the wavelength range 200-1 100 nm has been designed for the Rijnhuizen Tokamak Project (RTP). The plasma is viewed from five directions in one poloidal plane with a total of 80 detectors. An optical imaging system consisting of two spherical mirrors for each viewing direct

  2. Polymer Optical Fibre Sensors for Endoscopic Opto-Acoustic Imaging

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet;

    2015-01-01

    in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference...

  3. Nanodiamond Landmarks for Subcellular Multimodal Optical and Electron Imaging

    CERN Document Server

    Zurbuchen, Mark A; Kohan, Sirus A; Leung, Belinda; Bouchard, Louis-S

    2015-01-01

    There is a growing need for biolabels that can be used in both optical and electron microscopies, are non-cytotoxic, and do not photobleach. Such biolabels could enable targeted nanoscale imaging of sub-cellular structures, and help to establish correlations between conjugation-delivered biomolecules and function. Here we demonstrate a subcellular multi-modal imaging methodology that enables localization of inert particulate probes, consisting of nanodiamonds having fluorescent nitrogen-vacancy centers. These are functionalized to target specific structures, and are observable by both optical and electron microscopies. Nanodiamonds targeted to the nuclear pore complex are rapidly localized in electron-microscopy diffraction mode to enable "zooming-in" to regions of interest for detailed structural investigations. Optical microscopies reveal nanodiamonds for in-vitro tracking or uptake-confirmation. The approach is general, works down to the single nanodiamond level, and can leverage the unique capabilities of...

  4. Human brain activity with functional NIR optical imager

    Science.gov (United States)

    Luo, Qingming

    2001-08-01

    In this paper we reviewed the applications of functional near infrared optical imager in human brain activity. Optical imaging results of brain activity, including memory for new association, emotional thinking, mental arithmetic, pattern recognition ' where's Waldo?, occipital cortex in visual stimulation, and motor cortex in finger tapping, are demonstrated. It is shown that the NIR optical method opens up new fields of study of the human population, in adults under conditions of simulated or real stress that may have important effects upon functional performance. It makes practical and affordable for large populations the complex technology of measuring brain function. It is portable and low cost. In cognitive tasks subjects could report orally. The temporal resolution could be millisecond or less in theory. NIR method will have good prospects in exploring human brain secret.

  5. Alternative optical concept for electron cyclotron emission imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J. X., E-mail: jsliu9@berkeley.edu [Department of Physics, University of California Berkeley, Berkeley, California 94720 (United States); Milbourne, T. [Department of Physics, College of William and Mary, Williamsburg, Virginia 23185 (United States); Bitter, M.; Delgado-Aparicio, L.; Dominguez, A.; Efthimion, P. C.; Hill, K. W.; Kramer, G. J.; Kung, C.; Pablant, N. A.; Tobias, B. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States); Kubota, S. [Department of Physics, University of California Los Angeles, Los Angeles, California 90095 (United States); Kasparek, W. [Department of Electrical Engineering, University of Stuttgart, Stuttgart (Germany); Lu, J. [Department of Physics, Chongqing University, Chongqing 400044 (China); Park, H. [Ulsan National Institute of Science and Technology, Ulsan 689-798 (Korea, Republic of)

    2014-11-15

    The implementation of advanced electron cyclotron emission imaging (ECEI) systems on tokamak experiments has revolutionized the diagnosis of magnetohydrodynamic (MHD) activities and improved our understanding of instabilities, which lead to disruptions. It is therefore desirable to have an ECEI system on the ITER tokamak. However, the large size of optical components in presently used ECEI systems have, up to now, precluded the implementation of an ECEI system on ITER. This paper describes a new optical ECEI concept that employs a single spherical mirror as the only optical component and exploits the astigmatism of such a mirror to produce an image with one-dimensional spatial resolution on the detector. Since this alternative approach would only require a thin slit as the viewing port to the plasma, it would make the implementation of an ECEI system on ITER feasible. The results obtained from proof-of-principle experiments with a 125 GHz microwave system are presented.

  6. Intrinsic optical signal imaging of retinal physiology: a review

    Science.gov (United States)

    Yao, Xincheng; Wang, Benquan

    2015-09-01

    Intrinsic optical signal (IOS) imaging promises to be a noninvasive method for high-resolution examination of retinal physiology, which can advance the study and diagnosis of eye diseases. While specialized optical instruments are desirable for functional IOS imaging of retinal physiology, in depth understanding of multiple IOS sources in the complex retinal neural network is essential for optimizing instrument designs. We provide a brief overview of IOS studies and relationships in rod outer segment suspensions, isolated retinas, and intact eyes. Recent developments of line-scan confocal and functional optical coherence tomography (OCT) instruments have allowed in vivo IOS mapping of photoreceptor physiology. Further improvements of the line-scan confocal and functional OCT systems may provide a feasible solution to pursue functional IOS mapping of human photoreceptors. Some interesting IOSs have already been detected in inner retinal layers, but better development of the IOS instruments and software algorithms is required to achieve optimal physiological assessment of inner retinal neurons.

  7. Optical Coherence Tomography in Cancer Imaging

    Science.gov (United States)

    Nam, Ahhyun Stephanie; Vakoc, Benjamin; Blauvelt, David; Chico-Calero, Isabel

    Investigations into the biology of cancer and novel cancer therapies rely on preclinical mouse models and traditional histological endpoints. Drawbacks of this approach include a limit in the number of time points for evaluation and an increased number of animals per study. This has motivated the use of intravital microscopy, which can provide longitudinal imaging of critical tumor parameters. Here, the capabilities of OCT as an intravital microscopy of the tumor microenvironment are summarized, and the state of OCT adoption into cancer research is summarized.

  8. Reflective optical imaging system for extreme ultraviolet wavelengths

    Science.gov (United States)

    Viswanathan, V.K.; Newnam, B.E.

    1993-05-18

    A projection reflection optical system has two mirrors in a coaxial, four reflection configuration to reproduce the image of an object. The mirrors have spherical reflection surfaces to provide a very high resolution of object feature wavelengths less than 200 [mu]m, and preferably less than 100 [mu]m. An image resolution of features less than 0.05-0.1 [mu]m, is obtained over a large area field; i.e., 25.4 mm [times] 25.4 mm, with a distortion less than 0.1 of the resolution over the image field.

  9. In vivo multimodal nonlinear optical imaging of mucosal tissue

    Science.gov (United States)

    Sun, Ju; Shilagard, Tuya; Bell, Brent; Motamedi, Massoud; Vargas, Gracie

    2004-05-01

    We present a multimodal nonlinear imaging approach to elucidate microstructures and spectroscopic features of oral mucosa and submucosa in vivo. The hamster buccal pouch was imaged using 3-D high resolution multiphoton and second harmonic generation microscopy. The multimodal imaging approach enables colocalization and differentiation of prominent known spectroscopic and structural features such as keratin, epithelial cells, and submucosal collagen at various depths in tissue. Visualization of cellular morphology and epithelial thickness are in excellent agreement with histological observations. These results suggest that multimodal nonlinear optical microscopy can be an effective tool for studying the physiology and pathology of mucosal tissue.

  10. Magnetic resonance imaging of traumatic transection of the optic chiasm

    Energy Technology Data Exchange (ETDEWEB)

    De Nunzio, M.; McAuliffe, W.; Chakera, T.M.H. [Royal Perth Hospital, Perth, WA (Australia). Department of Diagnostic Radiology

    1997-05-01

    Traumatic lesions of the visual pathways are an uncommon, but well recognized complication of head injury. Optimal visualization of such lesions is probably best achieved using multiplanar magnetic resonance (MR) imaging. A case of complete sagittal transection of the optic chiasm using MR imaging is reported. This has been rarely documented in the literature. Computerized tomography demonstrated a basal skull fracture extending through the sphenoid sinus and into the floor of the pituitary fossa. However, MRI is advocated as the optimal imaging modality for the diagnosis of traumatic lesions of suprasellar structures, perhaps obviating the need for future investigations. 7 refs., 1 fig.

  11. Primate retina imaging with polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Ducros, Mathieu G.; Marsack, Jason D.; Rylander, H. Grady; Thomsen, Sharon L.; Milner, Thomas E.

    2001-12-01

    Polarization-sensitive optical coherence tomography (PSOCT) is applied to determine the depth-resolved polarization state of light backreflected from the eye. The birefringence of the retinal nerve fiber layer (RNFL) was observed and measured from PSOCT images recorded postmortem in a Rhesus monkey. An image-processing algorithm was developed to identify birefringent regions in acquired PSOCT retinal images and automatically determine the thickness of the RNFL. Values of the RNFL thickness determined from histology and PSOCT were compared. PSOCT may provide a new method to determine RNFL thickness and birefringence for glaucoma diagnostics.

  12. Gen-2 hand-held optical imager towards cancer imaging: reflectance and transillumination phantom studies.

    Science.gov (United States)

    Gonzalez, Jean; Roman, Manuela; Hall, Michael; Godavarty, Anuradha

    2012-01-01

    Hand-held near-infrared (NIR) optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2) hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s) allows for reflectance imaging (as in ultrasound) and transillumination or compressed imaging (as in X-ray mammography). Phantom studies were performed to demonstrate two-dimensional (2D) target detection via reflectance and transillumination imaging at various target depths (1-5 cm deep) and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  13. VIDA (Vlti Imaging with a Densified Array), a densified pupil combiner proposed for snapshot imaging with the VLTI

    Science.gov (United States)

    Lardiere, Olivier; Labeyrie, Antoine; Mourard, Denis; Riaud, Pierre; Arnold, Luc; Dejonghe, Julien; Gillet, Sophie

    2003-02-01

    Only in the recent years did it become realized that multi-aperture interferometric arrays could provide direct snapshot images and coronagraphic images in a non-Fizeau mode. Whereas homothetic mapping of entrance pupil to exit pupil is useless when the aperture is higly diluted, a "densified-pupil" or "hypertelescope" imaging mode can concentrate most light into a high-resolution Airy peak. In addition to the luminosity gain, there is a contrast gain particularly valuable for stellar coronagraphy and exoplanets finding. The current VLTI is able to combine light from two telescopes coherently. In subsequent phases, a combiner is planned for applying closure phase with up to eight telescopes (UT and AT). The small number of apertures currently considered at the VLTI, does not take full advantage of hypertelescope imaging, but still performs significantly better than other observing modes (+3.8mag gain in comparison with Fizeau mode). We propose some possible optical scheme for a densified-pupil combiner for the VLTI. Beyond its science value, the proposed instrument can serve as a precursor for many-element post-VLTI hypertelescopes.

  14. Serial Diffusion Tensor Imaging of the Optic Radiations after Acute Optic Neuritis.

    Science.gov (United States)

    Kolbe, Scott C; van der Walt, Anneke; Butzkueven, Helmut; Klistorner, Alexander; Egan, Gary F; Kilpatrick, Trevor J

    2016-01-01

    Previous studies have reported diffusion tensor imaging (DTI) changes within the optic radiations of patients after optic neuritis (ON). We aimed to study optic radiation DTI changes over 12 months following acute ON and to study correlations between DTI parameters and damage to the optic nerve and primary visual cortex (V1). We measured DTI parameters [fractional anisotropy (FA), axial diffusivity (AD), radial diffusivity (RD), and mean diffusivity (MD)] from the optic radiations of 38 acute ON patients at presentation and 6 and 12 months after acute ON. In addition, we measured retinal nerve fibre layer thickness, visual evoked potential amplitude, optic radiation lesion load, and V1 thickness. At baseline, FA was reduced and RD and MD were increased compared to control. Over 12 months, FA reduced in patients at an average rate of -2.6% per annum (control = -0.51%; p = 0.006). Change in FA, RD, and MD correlated with V1 thinning over 12 months (FA: R = 0.450, p = 0.006; RD: R = -0.428, p = 0.009; MD: R = -0.365, p = 0.029). In patients with no optic radiation lesions, AD significantly correlated with RNFL thinning at 12 months (R = 0.489, p = 0.039). In conclusion, DTI can detect optic radiation changes over 12 months following acute ON that correlate with optic nerve and V1 damage.

  15. Serial Diffusion Tensor Imaging of the Optic Radiations after Acute Optic Neuritis

    Directory of Open Access Journals (Sweden)

    Scott C. Kolbe

    2016-01-01

    Full Text Available Previous studies have reported diffusion tensor imaging (DTI changes within the optic radiations of patients after optic neuritis (ON. We aimed to study optic radiation DTI changes over 12 months following acute ON and to study correlations between DTI parameters and damage to the optic nerve and primary visual cortex (V1. We measured DTI parameters [fractional anisotropy (FA, axial diffusivity (AD, radial diffusivity (RD, and mean diffusivity (MD] from the optic radiations of 38 acute ON patients at presentation and 6 and 12 months after acute ON. In addition, we measured retinal nerve fibre layer thickness, visual evoked potential amplitude, optic radiation lesion load, and V1 thickness. At baseline, FA was reduced and RD and MD were increased compared to control. Over 12 months, FA reduced in patients at an average rate of −2.6% per annum (control = −0.51%; p=0.006. Change in FA, RD, and MD correlated with V1 thinning over 12 months (FA: R=0.450, p=0.006; RD: R=-0.428, p=0.009; MD: R=-0.365, p=0.029. In patients with no optic radiation lesions, AD significantly correlated with RNFL thinning at 12 months (R=0.489, p=0.039. In conclusion, DTI can detect optic radiation changes over 12 months following acute ON that correlate with optic nerve and V1 damage.

  16. New concept for combining three telescopes with integrated optics: multi-mode interferences (MMI)

    Science.gov (United States)

    Rooms, Frederic; Morand, Alain; Schanen-Duport, Isabelle; Broquin, Jean-Emmanuel; Haguenauer, Pierre; Berger, Jean-Philippe; Martin, M.; Benyattou, Taha

    2003-02-01

    Integrated optics technologies are an attractive alternative to classical bulk optics for the beam combination function of an interferometer. We propose a new integrated optics combiner for three apertures giving access to the closure phase on each output. It uses a multimode interference combination scheme realized by ion exchange on a glass substrate. This paper describes the theoretical behaviour of the beam combiner and its design constraints. Its interferometric behaviour is simulated and first experimental results using for the first time, as far as we know, a Near field Scanning Optical Measurement (NSOM) technique are discussed.

  17. Stellar Intensity Interferometry: Prospects for sub-milliarcsecond optical imaging

    CERN Document Server

    Dravins, Dainis; Jensen, Hannes; Nuñez, Paul D

    2012-01-01

    Using kilometric arrays of air Cherenkov telescopes, intensity interferometry may increase the spatial resolution in optical astronomy by an order of magnitude, enabling images of rapidly rotating stars with structures in their circumstellar disks and winds, or mapping out patterns of nonradial pulsations across stellar surfaces. Intensity interferometry (pioneered by Hanbury Brown and Twiss) connects telescopes only electronically, and is practically insensitive to atmospheric turbulence and optical imperfections, permitting observations over long baselines and through large airmasses, also at short optical wavelengths. The required large telescopes with very fast detectors are becoming available as arrays of air Cherenkov telescopes, distributed over a few square km. Digital signal handling enables very many baselines to be synthesized, while stars are tracked with electronic time delays, thus synthesizing an optical interferometer in software. Simulated observations indicate limiting magnitudes around m(v)...

  18. Quantitative Analysis of HER2 Receptor Expression In Vivo by Near-Infrared Optical Imaging

    Directory of Open Access Journals (Sweden)

    Victor Chernomordik

    2010-07-01

    Full Text Available Human epidermal growth factor receptor 2 (HER2 overexpression in breast cancers is associated with poor prognosis and resistance to therapy. Current techniques for estimating this important characteristic use ex vivo assays that require tissue biopsies. We suggest a novel noninvasive method to characterize HER2 expression in vivo, using optical imaging, based on HER2-specific probes (albumin-binding domain–fused-(ZHER2:3422-Cys Affibody molecules [Affibody AB, Solna, Sweden], labeled with Alexa Fluor 750 [Molecular Probes, Invitrogen, Carlsbad, CA] that could be used concomitantly with HER2-targeted therapy. Subcutaneous tumor xenografts, expressing different levels of HER2, were imaged with a near-infrared fluorescence small-animal imaging system at several times postinjection of the probe. The compartmental ligand-receptor model was used to calculate HER2 expression from imaging data. Correlation between HER2 amplification/overexpression in tumor cells and parameters, directly estimated from the sequence of optical images, was observed (eg, experimental data for BT474 xenografts indicate that initial slope, characterizing the temporal dependence of the fluorescence intensity detected in the tumor, linearly depends on the HER2 expression, as measured ex vivo by an enzyme-linked immunosorbent assay for the same tumor. The results obtained from tumors expressing different levels of HER2 substantiate a similar relationship between the initial slope and HER2 amplification/overexpression. This work shows that optical imaging, combined with mathematical modeling, allows noninvasive monitoring of HER2 expression in vivo.

  19. Direct design of two freeform optical surfaces for wide field of view line imaging applications

    Science.gov (United States)

    Nie, Yunfeng; Thienpont, Hugo; Duerr, Fabian

    2016-04-01

    In this paper, we propose a multi-fields direct design method aiming to calculate two freeform surfaces with an entrance pupil incorporated for wide field of view on-axis line imaging applications. Both infinite and finite conjugate objectives can be designed with this approach. Since a wide angle imaging system requires more than few discrete perfect imaging points, the multi-fields design approach is based on partial coupling of multiple fields, which guarantees a much more balanced imaging performance over the full field of view. The optical path lengths (OPLs) and image points of numerous off-axis fields are calculated during the procedure, thus very few initial parameters are needed. The procedure to calculate such a freeform lens is explained in detail. We have designed an exemplary monochromatic single lens to demonstrate the functionality of the design method. A rotationally symmetric counterpart following the same specifications is compared in terms of RMS spot radius to demonstrate the clear benefit that freeform lens brings to on-axis line imaging systems. In addition, a practical achromatic wide angle objective is designed by combining our multi-fields design method with classic optical design strategies, serving as a very good starting point for further optimization in a commercial optical design program. The results from the perspective of aberrations plots and MTF values show a very good and well balanced performance over the full field of view.

  20. Fusion of Spaceborne Optical and SAR Images for Building Height Quick Extraction in Big Urban Areas

    Directory of Open Access Journals (Sweden)

    TIAN Feng

    2017-07-01

    Full Text Available The spaceborne high-resolution optical images and synthetic aperture radar (SAR images are applied to extract building height in urban areas widely. But the lack of optical satellite parameters along with the SAR images' incomplete scattering characteristics and inefficient extraction make the application flawed. To cure the above problems, we investigated the joint use of the spaceborne high-resolution optical images and SAR images to extract building height information quickly in big urban areas. The chain is decomposed into the main following steps: First, the building shadows are extracted by integrating support vector machines (SVM with morphological shadow index (MSI and their lengths are measured automatically. Then, the height extraction from SAR images based on a model matching technique for some appropriate samples. Finally, obtain the other heights based on the simple linear regression analysis. This approach which combines the data and feature from different satellite systems to make up the flaws for each other is not only efficient and low-cost, but also satisfy the basic accuracy requirement.

  1. Evaluation of tissue optical properties from light distribution images

    Science.gov (United States)

    Tsai, Cheng-Lun; Chang, Ming; Hsieh, Jui-Hsiang; Yang, Yi-Fong; Chou, Yi-Sheong

    2000-06-01

    Images of light distribution in biological soft tissue we used to study the optical characteristics of tissue. The light distribution image was taken under a microscope with light injected through a pinhole close to the edge of the top surface. Images taken on skin, fat, and muscle tissues were compared to study the effect of cellular structure and temperature on the light intensity distribution. Monte Carlo simulation with the same conditions was also performed to simulate the light intensity distribution in tissue for comparison. The anisotropy scattering of light in tissue is affected by the tissue microscopic structure, such as the direction of muscle tissue fibers. The change in optical properties of fat and muscle tissue with temperature was observed. The two-dimensional light distribution images offer more information than general reflectance and transmission measurements. By matching the simulated light intensity distribution with the light distribution image, the optical properties of biological tissue could be estimated. This method might be applied in tissue engineering as an economic way for evaluating the microscopic structure of tissue.

  2. Optical Imaging for Stem Cell Differentiation to Neuronal Lineage

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Do Won; Lee, Dong Soo [Seoul National Univ., Seoul (Korea, Republic of)

    2012-03-15

    In regenerative medicine, the prospect of stem cell therapy hold great promise for the recovery of injured tissues and effective treatment of intractable diseases. Tracking stem cell fate provides critical information to understand and evaluate the success of stem cell therapy. The recent emergence of in vivo noninvasive molecular imaging has enabled assessment of the behavior of grafted stem cells in living subjects. In this review, we provide an overview of current optical imaging strategies based on cell or tissue specific reporter gene expression and of in vivo methods to monitor stem cell differentiation into neuronal lineages. These methods use optical reporters either regulated by neuron-specific promoters or containing neuron-specific microRNA binding sites. Both systems revealed dramatic changes in optical reporter imaging signals in cells differentiating a yeast GAL4 amplification system or an engineering-enhanced luciferase reported gene. Furthermore, we propose an advanced imaging system to monitor neuronal differentiation during neurogenesis that uses in vivo multiplexed imaging techniques capable of detecting several targets simultaneously.

  3. Adaptive optics with pupil tracking for high resolution retinal imaging.

    Science.gov (United States)

    Sahin, Betul; Lamory, Barbara; Levecq, Xavier; Harms, Fabrice; Dainty, Chris

    2012-02-01

    Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and high cost of the present research systems have to be addressed. We present a new method to control the deformable mirror in real time based on pupil tracking measurements which uses the default camera for the alignment of the eye in the retinal imaging system and requires no extra cost or hardware. We also present the first experiments done with a compact adaptive optics flood illumination fundus camera where it was possible to compensate for the higher order aberrations of a moving model eye and in vivo in real time based on pupil tracking measurements, without the real time contribution of a wavefront sensor. As an outcome of this research, we showed that pupil tracking can be effectively used as a low cost and practical adaptive optics tool for high resolution retinal imaging because eye movements constitute an important part of the ocular wavefront dynamics.

  4. Optical imaging for stem cell differentiation to neuronal lineage.

    Science.gov (United States)

    Hwang, Do Won; Lee, Dong Soo

    2012-03-01

    In regenerative medicine, the prospect of stem cell therapy holds great promise for the recovery of injured tissues and effective treatment of intractable diseases. Tracking stem cell fate provides critical information to understand and evaluate the success of stem cell therapy. The recent emergence of in vivo noninvasive molecular imaging has enabled assessment of the behavior of grafted stem cells in living subjects. In this review, we provide an overview of current optical imaging strategies based on cell- or tissue-specific reporter gene expression and of in vivo methods to monitor stem cell differentiation into neuronal lineages. These methods use optical reporters either regulated by neuron-specific promoters or containing neuron-specific microRNA binding sites. Both systems revealed dramatic changes in optical reporter imaging signals in cells differentiating into a neuronal lineage. The detection limit of weak promoters or reporter genes can be greatly enhanced by adopting a yeast GAL4 amplification system or an engineering-enhanced luciferase reporter gene. Furthermore, we propose an advanced imaging system to monitor neuronal differentiation during neurogenesis that uses in vivo multiplexed imaging techniques capable of detecting several targets simultaneously.

  5. Cellular resolution volumetric in vivo retinal imaging with adaptive optics-optical coherence tomography.

    Science.gov (United States)

    Zawadzki, Robert J; Choi, Stacey S; Fuller, Alfred R; Evans, Julia W; Hamann, Bernd; Werner, John S

    2009-03-02

    Ultrahigh-resolution adaptive optics-optical coherence tomography (UHR-AO-OCT) instrumentation allowing monochromatic and chromatic aberration correction was used for volumetric in vivo retinal imaging of various retinal structures including the macula and optic nerve head (ONH). Novel visualization methods that simplify AO-OCT data viewing are presented, and include co-registration of AO-OCT volumes with fundus photography and stitching of multiple AO-OCT sub-volumes to create a large field of view (FOV) high-resolution volume. Additionally, we explored the utility of Interactive Science Publishing by linking all presented AO-OCT datasets with the OSA ISP software.

  6. Advanced capabilities of the multimodal adaptive optics imager

    Science.gov (United States)

    Hammer, Daniel X.; Ferguson, R. D.; Mujat, Mircea; Biss, David P.; Iftimia, Nicusor V.; Patel, Ankit H.; Plumb, Emily; Campbell, Melanie; Norris, Jennifer L.; Dubra, Alfredo; Chui, Toco Y. P.; Akula, James D.; Fulton, Anne B.

    2011-03-01

    We recently developed several versions of a multimodal adaptive optics (AO) retinal imager, which includes highresolution scanning laser ophthalmoscopy (SLO) and Fourier domain optical coherence tomography (FDOCT) imaging channels as well as an auxiliary wide-field line scanning ophthalmoscope (LSO). Some versions have also been equipped with a fluorescence channel and a retinal tracker. We describe the performance of three key features of the multimodal AO system including: simultaneous SLO/OCT imaging, which allows SLO/OCT co-registration; a small animal imaging port, which adjusts the beam diameter at the pupil from 7.5 to 2.5 mm for use with small animals ubiquitous in biological research or for extended depth-of-focus imaging in humans; and slow scan Doppler flowmetry imaging using the wide field auxiliary LSO imaging channel. The systems are currently deployed in several ophthalmology clinics and research laboratories and several investigations have commenced on patients with a variety of retinal diseases and animals in vision research.

  7. Direct model fitting to combine dithered ACS images

    Science.gov (United States)

    Mahmoudian, H.; Wucknitz, O.

    2013-08-01

    The information lost in images of undersampled CCD cameras can be recovered with the technique of "dithering". A number of subexposures is taken with sub-pixel shifts in order to record structures on scales smaller than a pixel. The standard method to combine such exposures, "Drizzle", averages after reversing the displacements, including rotations and distortions. More sophisticated methods are available to produce, e.g., Nyquist sampled representations of band-limited inputs. While the combined images produced by these methods can be of high quality, their use as input for forward-modelling techniques in gravitational lensing is still not optimal, because the residual artefacts still affect the modelling results in unpredictable ways. In this paper we argue for an overall modelling approach that takes into account the dithering and the lensing without the intermediate product of a combined image. As one building block we introduce an alternative approach to combine dithered images by direct model fitting with a least-squares approach including a regularization constraint. We present tests with simulated and real data that show the quality of the results. The additional effects of gravitational lensing and the convolution with an instrumental point spread function can be included in a natural way, avoiding the possible systematic errors of previous procedures.

  8. Combination of acoustical radiosity and the image source method

    DEFF Research Database (Denmark)

    Koutsouris, Georgios I; Brunskog, Jonas; Jeong, Cheol-Ho

    2013-01-01

    A combined model for room acoustic predictions is developed, aiming to treat both diffuse and specular reflections in a unified way. Two established methods are incorporated: acoustical radiosity, accounting for the diffuse part, and the image source method, accounting for the specular part...

  9. Parametric imaging of viscoelasticity using optical coherence elastography

    Science.gov (United States)

    Wijesinghe, Philip; McLaughlin, Robert A.; Sampson, David D.; Kennedy, Brendan F.

    2015-03-01

    We demonstrate imaging of soft tissue viscoelasticity using optical coherence elastography. Viscoelastic creep deformation is induced in tissue using step-like compressive loading and the resulting time-varying deformation is measured using phase-sensitive optical coherence tomography. From a series of co-located B-scans, we estimate the local strain rate as a function of time, and parameterize it using a four-parameter Kelvin-Voigt model of viscoelastic creep. The estimated viscoelastic strain and time constant are used to visualize viscoelastic creep in 2D, dual-parameter viscoelastograms. We demonstrate our technique on six silicone tissue-simulating phantoms spanning a range of viscoelastic parameters. As an example in soft tissue, we report viscoelastic contrast between muscle and connective tissue in fresh, ex vivo rat gastrocnemius muscle and mouse abdominal transection. Imaging viscoelastic creep deformation has the potential to provide complementary contrast to existing imaging modalities, and may provide greater insight into disease pathology.

  10. Imaging of oral pathological tissue using optical coherence tomography

    Science.gov (United States)

    Canjau, Silvana; Todea, Carmen; Sinescu, Cosmin; Duma, Virgil-Florin; Topala, Florin I.; Podoleanu, Adrian G.

    2014-01-01

    Oral squamous cell carcinoma (OSCC) constitutes 90% of oral cancer. Early detection is a cornerstone to improve survival. Interaction of light with tissues may highlight changes in tissue structure and metabolism. We propose optical coherence tomography (OCT), as a non-invasive diagnosis method, being a new high-resolution optical technique that permits tri-dimensional (3-D), real-time imaging of near surface abnormalities in complex tissues. In this study half of the excisional biopsy was directed to the pathologist and the other half was assigned for OCT investigation. Histopathology validated the results. Areas of OSCC of the buccal mucosa were identified in the OCT images. The elements obserced included extensive epithelial down-growth, the disruption of the basement membrane, with areas of erosion, an epithelial layer that was highly variable in thickness and invasion into the sub-epithelial layers. Therefore, OCT appears to be a highly promising imaging modality.

  11. A minimal optical trapping and imaging microscopy system.

    Directory of Open Access Journals (Sweden)

    Carmen Noemí Hernández Candia

    Full Text Available We report the construction and testing of a simple and versatile optical trapping apparatus, suitable for visualizing individual microtubules (∼25 nm in diameter and performing single-molecule studies, using a minimal set of components. This design is based on a conventional, inverted microscope, operating under plain bright field illumination. A single laser beam enables standard optical trapping and the measurement of molecular displacements and forces, whereas digital image processing affords real-time sample visualization with reduced noise and enhanced contrast. We have tested our trapping and imaging instrument by measuring the persistence length of individual double-stranded DNA molecules, and by following the stepping of single kinesin motor proteins along clearly imaged microtubules. The approach presented here provides a straightforward alternative for studies of biomaterials and individual biomolecules.

  12. Optical double-image encryption and authentication by sparse representation.

    Science.gov (United States)

    Mohammed, Emad A; Saadon, H L

    2016-12-10

    An optical double-image encryption and authentication method by sparse representation is proposed. The information from double-image encryption can be integrated into a sparse representation. Unlike the traditional double-image encryption technique, only sparse (partial) data from the encrypted data is adopted for the authentication process. Simulation results demonstrate that the correct authentication results are achieved even with partial information from the encrypted data. The randomly selected sparse encrypted information will be used as an effective key for a security system. Therefore, the proposed method is feasible, effective, and can provide an additional security layer for optical security systems. In addition, the method also achieved the general requirements of storage and transmission due to a high reduction of the encrypted information.

  13. Chemical shift selective magnetic resonance imaging of the optic nerve in patients with acute optic neuritis

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, H.B.W.; Thomsen, C.; Frederiksen, J.; Henriksen, O.; Olesen, J.

    Optic neuritis is often the first manifestion of multiple sclerosis (MS). Sixteen patients with acute optic neuritis and one patient with benign intracranial hypertension (BIH) were investigated by magnetic resonance imaging, using a chemical shift selective double spin echo sequence. In 3 of the 16 patients, abnormalities were seen. In one patient with bilateral symptoms, signal hyperintensity and swelling of the right side of the chiasm were found. In another patient the optic nerve was found diffusely enlarged with only a marginally increased signal in the second echo. In the third patient an area of signal hyperintensity and swelling was seen in the left optic nerve. In the patient with BIH the subarachnoid space which surrounds the optic nerves was enlarged. Even using this refined pulse sequence, avoiding the major artefact in imaging the optic nerve, the chemical shift artefact, lesions were only shown in 3/16 (19%) of the patients with optic neuritis. Nevertheless, the presented chemical shift selective double spin echo sequence may be of great value for detection of retrobulbar lesions.

  14. Three-dimensional imaging system combining vision and ultrasonics

    Science.gov (United States)

    Wykes, Catherine; Chou, Tsung N.

    1994-11-01

    Vision systems are being applied to a wide range of inspection problems in manufacturing. In 2D systems, a single video camera captures an image of the object and application of suitable image processing techniques enables information about dimension, shape and the presence of features and flaws to be extracted from the image. This can be used to recognize, inspect and/or measure the part. 3D measurement is also possible with vision systems but requires the use of either two or more cameras, or structured lighting (i.e. stripes or grids) and the processing of such images is necessarily considerably more complex, and therefore slower and more expensive than 3D imaging. Ultrasonic imaging is widely used in medical and NDT applications to give 3D images; in these systems, the ultrasound is propagated into a liquid or a solid. Imaging using air-borne ultrasound is much less advanced, mainly due to the limited availability of suitable sensors. Unique 2D ultrasonic ranging systems using in-house built phased arrays have been developed in Nottingham which enable both the range and bearing of targets to be measured. The ultrasonic/vision system will combine the excellent lateral resolution of a vision system with the straightforward range acquisition of the ultrasonic system. The system is expected to extend the use of vision systems in automation, particularly in the area of automated assembly where it can eliminate the need for expensive jigs and orienting part-feeders.

  15. Rapid production of structural color images with optical data storage capabilities

    Science.gov (United States)

    Rezaei, Mohamad; Jiang, Hao; Qarehbaghi, Reza; Naghshineh, Mohammad; Kaminska, Bozena

    2015-03-01

    In this paper, we present novel methods to produce structural color image for any given color picture using a pixelated generic stamp named nanosubstrate. The nanosubstrate is composed of prefabricated arrays of red, green and blue subpixels. Each subpixel has nano-gratings and/or sub-wavelength structures which give structural colors through light diffraction. Micro-patterning techniques were implemented to produce the color images from the nanosubstrate by selective activation of subpixels. The nano-grating structures can be nanohole arrays, which after replication are converted to nanopillar arrays or vice versa. It has been demonstrated that visible and invisible data can be easily stored using these fabrication methods and the information can be easily read. Therefore the techniques can be employed to produce personalized and customized color images for applications in optical document security and publicity, and can also be complemented by combined optical data storage capabilities.

  16. Hubble Space Telescope Optical Imaging of the Eroding Debris Disk HD 61005

    CERN Document Server

    Maness, H L; Peek, K M G; Chiang, E I; Scherer, K; Fitzgerald, M P; Graham, James R; Hines, D C; Schneider, G; Metchev, S A

    2009-01-01

    We present Hubble Space Telescope optical coronagraphic polarization imaging observations of the dusty debris disk HD 61005. The scattered light intensity image and polarization structure reveal a highly inclined disk with a clear asymmetric, swept back component, suggestive of significant interaction with the ambient interstellar medium. The combination of our new data with the published 1.1 micron discovery image shows that the grains are blue scattering with no strong color gradient as a function of radius, implying predominantly sub-micron sized grains. We investigate possible explanations that could account for the observed swept back, asymmetric morphology. Previous work has suggested that HD 61005 may be interacting with a cold, unusually dense interstellar cloud. However, limits on the intervening interstellar gas column density from an optical spectrum of HD 61005 in the Na I D lines render this possibility unlikely. Instead, HD 61005 may be embedded in a more typical warm, low-density cloud that int...

  17. Perceptual image quality in normalized LOG domain for Adaptive Optics image post-processing

    Science.gov (United States)

    Guo, Shiping; Zhang, Rongzhi; Li, Jisheng; Zou, Jianhua; Liu, Changhai; Gao, Weizhe

    2015-08-01

    Adaptive Optics together with subsequent post-processing techniques obviously improve the resolution of turbulencedegraded images in ground-based space objects detection and identification. The most common method for frame selection and stopping iteration in post-processing has always been subjective viewing of the images due to a lack of widely agreed-upon objective quality metric. Full reference metrics are not applicable for assessing the field data, no-reference metrics tend to perform poor sensitivity for Adaptive Optics images. In the present work, based on the Laplacian of Gaussian (LOG) local contrast feature, a nonlinear normalization is applied to transform the input image into a normalized LOG domain; a quantitative index is then extracted in this domain to assess the perceptual image quality. Experiments show this no-reference quality index is highly consistent with the subjective evaluation of input images for different blur degree and different iteration number.

  18. Optical Fourier techniques for medical image processing and phase contrast imaging.

    Science.gov (United States)

    Yelleswarapu, Chandra S; Kothapalli, Sri-Rajasekhar; Rao, D V G L N

    2008-04-01

    This paper briefly reviews the basics of optical Fourier techniques (OFT) and applications for medical image processing as well as phase contrast imaging of live biological specimens. Enhancement of microcalcifications in a mammogram for early diagnosis of breast cancer is the main focus. Various spatial filtering techniques such as conventional 4f filtering using a spatial mask, photoinduced polarization rotation in photosensitive materials, Fourier holography, and nonlinear transmission characteristics of optical materials are discussed for processing mammograms. We also reviewed how the intensity dependent refractive index can be exploited as a phase filter for phase contrast imaging with a coherent source. This novel approach represents a significant advance in phase contrast microscopy.

  19. Imaging patients with glaucoma using spectral-domain optical coherence tomography and optical microangiography

    Science.gov (United States)

    Auyeung, Kris; Auyeung, Kelsey; Kono, Rei; Chen, Chieh-Li; Zhang, Qinqin; Wang, Ruikang K.

    2015-03-01

    In ophthalmology, a reliable means of diagnosing glaucoma in its early stages is still an open issue. Past efforts, including forays into fluorescent angiography (FA) and early optical coherence tomography (OCT) systems, to develop a potential biomarker for the disease have been explored. However, this development has been hindered by the inability of the current techniques to provide useful depth and microvasculature information of the optic nerve head (ONH), which have been debated as possible hallmarks of glaucoma progression. We reasoned that a system incorporating a spectral-domain OCT (SD-OCT) based Optical Microangiography (OMAG) system, could allow an effective, non-invasive methodology to evaluate effects on microvasculature by glaucoma. SD-OCT follows the principle of light reflection and interference to produce detailed cross-sectional and 3D images of the eye. OMAG produces imaging contrasts via endogenous light scattering from moving particles, allowing for 3D image productions of dynamic blood perfusion at capillary-level resolution. The purpose of this study was to investigate the optic cup perfusion (flow) differences in glaucomatous and normal eyes. Images from three normal and five glaucomatous subjects were analyzed our OCT based OMAG system for blood perfusion and structural images, allowing for comparisons. Preliminary results from blood flow analysis revealed reduced blood perfusion within the whole-depth region encompassing the Lamina Cribrosa in glaucomatous cases as compared to normal ones. We conclude that our OCT-OMAG system may provide promise and viability for glaucoma screening.

  20. Nonlinear optical imaging characteristics in rat tail tendon

    Science.gov (United States)

    Liu, N. R.; Zhang, X. Z.; Qiu, Y. S.; Chen, R.

    2013-04-01

    The aim of this study was to examine the characteristics of skeletal muscle fibers in tail tendons, explore the content of intrinsic components at different depths and ascertain the optimum excitation wavelength, which will help to establish a relationship between diagnosis and therapy and the tendon injury. A multiphoton microscopic imaging system was used to achieve the images and spectra via an imaging mode and a Lambda mode, respectively. This work demonstrates that the skeletal muscle fibers of the tail tendon are in good order. Second harmonic generation (SHG) and two-photon excited fluorescence (TPEF) signals originating from certain intrinsic components are varied with depth, and the SHG/TPEF intensity ratios are varied at different excitation wavelengths. Below 800 nm is the optimum for cell TPEF, while above 800 nm is the optimum for SHG. With the development of imaging techniques, a nonlinear optical imaging system will be helpful to represent the functional behaviors of tissue related to tendon injury.

  1. Optical slicing of large scenes by synthetic aperture integral imaging

    Science.gov (United States)

    Navarro, Héctor; Saavedra, Genaro; Molina, Ainhoa; Martínez-Corral, Manuel; Martínez-Cuenca, Raúl; Javidi, Bahram

    2010-04-01

    Integral imaging (InI) technology was created with the aim of providing the binocular observers of monitors, or matrix display devices, with auto-stereoscopic images of 3D scenes. However, along the last few years the inventiveness of researches has allowed to find many other interesting applications of integral imaging. Examples of this are the application of InI in object recognition, the mapping of 3D polarization distributions, or the elimination of occluding signals. One of the most interesting applications of integral imaging is the production of views focused at different depths of the 3D scene. This application is the natural result of the ability of InI to create focal stacks from a single input image. In this contribution we present new algorithm for this optical slicing application, and show that it is possible the 3D reconstruction with improved lateral resolution.

  2. Optical-parametric-amplification applications to complex images

    Science.gov (United States)

    Vaughan, Peter M.

    2011-12-01

    Ultrafast optical pulses have many useful features. One in particular is their ability to exploit nonlinear processes due to their extremely short durations. We have used ultrafast optical pulses, primarily focused on the nonlinear processes of Polarization Gating and of Optical Parametric Amplification, one for measurement and the other for imaging purposes. For measurement, we have demonstrated a robust method of measurement to simultaneously measure both optical pulses used in a pump-probe type configuration. In these measurements, no initial information beyond the nonlinear interaction between the pulses is required. We refer to this method of pulse measurement as Double-Blind Polarization Gating FROG[1]. We have demonstrated this single-shot method for measuring two unknown pulses using one device. We have demonstrated this technique on three separate pulse pairs. We measured two Gaussian pulses with different amounts of chirp. We measured two double pulses with different pulse separations, and we have measured two extremely different pulses, where one was simple Gaussian and the other was a pulse train produced by an etalon. This method has no non-trivial ambiguities, has a reliable algorithm, and is automatically phase matched for all spectral bandwidths. In simulations[2], this method has proven to be extremely robust, measuring very complicated pulses with TBPs of ˜100 even in the presence of noise. In addition to pulse measurement, we have demonstrated the processes of Optical Parametric Amplification (OPA) applicability to imaging of complex objects[3]. We have done this where the Fourier transform plane is used during the interaction. We have amplified and wavelength converted a complex image. We report imaging of spatial features from 1.1 to 10.1 line pairs/millimeter (lp/mm) in the vertical dimension and from 2.0 to 16.0 lp/mm in the horizontal dimension. We observe a gain of ˜100, and, although our images were averaged over many shots, we used a

  3. Method to improve the performance of reflectance diffuse optical imaging based on polygonal optical fibers arrangement

    Institute of Scientific and Technical Information of China (English)

    Weitao Li; Zhiyu Qian; Ting Li

    2009-01-01

    In order to improve the performance of reflectance diffuse optical imaging(rDOI),a novel polynomial geometry(PG)of optical fibers arrangement is proposed.Polynomial geometry is based on the hexagonal geometry(HG)and multicentered double-density(MD)mode.The overlapping sensitivity matrix,area ratio(AR),reconstruction image,two-absorber model,arid contrast-to-noise ratio(CNR)in different depths are used to evaluate the performance of PG.The other three geometries including HG,rectangular geometry(RG),and MD mode are also compared with PG.The deformation of the reconstruction images is evaluted by circular ratio(CR).The results prove that the proposed PG has high performance and minimum deformation in quality of reconstruction image in rDOI.

  4. The importance of optical optimization in whole slide imaging (WSI) and digital pathology imaging.

    Science.gov (United States)

    Yagi, Yukako; Gilbertson, John R

    2008-07-15

    In the last 10 years, whole slide imaging (WSI) has seen impressive progress not only in image quality and scanning speed but also in the variety of systems available to pathologists. However, we have noticed that most systems have relatively simple optics axes and rely on software to optimize image quality and colour balance. While much can be done in software, this study examines the importance of optics, in particular optical filters, in WSI.Optical resolution is a function of the wavelength of light used and the numerical aperture of the lens system (Resolution = (f) wavelength/2 NA). When illumining light is not conditioned correctly with filters, there is a tendency for the wavelength to shift to longer values (more red) because of the characteristics of the lamps in common use. Most microscopes (but remarkably few WSI devices) correct for this with ND filter for brightness and Blue filter (depends on the light source) for colour correction.Using H&E slides research microscopes (Axiophot, Carl Zeiss MicroImaging, Inc. NY. Eclipse 50i., Nikon Inc. NY) at 20x, an attached digital camera (SPOT RT741 Slider Color, Diagnosis Instruments., MI USA), and a filter set, we examined the effect of filters and software enhancement on digital image quality. The focus value (as evaluated by focus evaluation software developed in house and SPOT imaging Software v4.6) was used as a proxy for image quality. Resolution of tissue features was best with the use of both the Blue and ND filters (in addition to software enhancement). Images without filters but with software enhancement while superficially good, lacked some details of specimen morphology and were unclear compared with the images with filters.The results indicate that the appropriate use of optical filters could measurably improve the appearance and resolution of WSI images.

  5. Image enhancement of optical images for binary system of melanocytes and keratinocytes

    Science.gov (United States)

    Takanezawa, S.; Baba, A.; Sako, Y.; Ozaki, Y.; Date, A.; Toyama, K.; Morita, S.

    2013-05-01

    Automatic determination of the cell shapes of large numbers of melanocytes based on optical images of human skin models have been largely unsuccessful (the complexities introduced by dendrites and the melanin pigmentation over the keratinocytes to give unclear outlines). Here, we present an image enhancement procedure for enhancing the contrast of images with removing the non-uniformity of background. The brightness is normalized also for the non-uniform population density of melanocytes.

  6. Building 3D aerial image in photoresist with reconstructed mask image acquired with optical microscope

    Science.gov (United States)

    Chou, C. S.; Tang, Y. P.; Chu, F. S.; Huang, W. C.; Liu, R. G.; Gau, T. S.

    2012-03-01

    Calibration of mask images on wafer becomes more important as features shrink. Two major types of metrology have been commonly adopted. One is to measure the mask image with scanning electron microscope (SEM) to obtain the contours on mask and then simulate the wafer image with optical simulator. The other is to use an optical imaging tool Aerial Image Measurement System (AIMSTM) to emulate the image on wafer. However, the SEM method is indirect. It just gathers planar contours on a mask with no consideration of optical characteristics such as 3D topography structures. Hence, the image on wafer is not predicted precisely. Though the AIMSTM method can be used to directly measure the intensity at the near field of a mask but the image measured this way is not quite the same as that on the wafer due to reflections and refractions in the films on wafer. Here, a new approach is proposed to emulate the image on wafer more precisely. The behavior of plane waves with different oblique angles is well known inside and between planar film stacks. In an optical microscope imaging system, plane waves can be extracted from the pupil plane with a coherent point source of illumination. Once plane waves with a specific coherent illumination are analyzed, the partially coherent component of waves could be reconstructed with a proper transfer function, which includes lens aberration, polarization, reflection and refraction in films. It is a new method that we can transfer near light field of a mask into an image on wafer without the disadvantages of indirect SEM measurement such as neglecting effects of mask topography, reflections and refractions in the wafer film stacks. Furthermore, with this precise latent image, a separated resist model also becomes more achievable.

  7. Assessing the quality of restored images in optical long-baseline interferometry

    CERN Document Server

    Gomes, Nuno; Thiébaut, Éric

    2016-01-01

    Assessing the quality of aperture synthesis maps is relevant for benchmarking image reconstruction algorithms, for the scientific exploitation of data from optical long-baseline interferometers, and for the design/upgrade of new/existing interferometric imaging facilities. Although metrics have been proposed in these contexts, no systematic study has been conducted on the selection of a robust metric for quality assessment. This article addresses the question: what is the best metric to assess the quality of a reconstructed image? It starts by considering several metrics, and selecting a few based on general properties. Then, a variety of image reconstruction cases is considered. The observational scenarios are phase closure and phase referencing at the Very Large Telescope Interferometer (VLTI), for a combination of two, three, four and six telescopes. End-to-end image reconstruction is accomplished with the MiRA software, and several merit functions are put to test. It is found that convolution by an effect...

  8. Adaptive anisotropic diffusion for noise reduction of phase images in Fourier domain Doppler optical coherence tomography.

    Science.gov (United States)

    Xia, Shaoyan; Huang, Yong; Peng, Shizhao; Wu, Yanfeng; Tan, Xiaodi

    2016-08-01

    Phase image in Fourier domain Doppler optical coherence tomography offers additional flow information of investigated samples, which provides valuable evidence towards accurate medical diagnosis. High quality phase images are thus desirable. We propose a noise reduction method for phase images by combining a synthetic noise estimation criteria based on local noise estimator (LNE) and distance median value (DMV) with anisotropic diffusion model. By identifying noise and signal pixels accurately and diffusing them with different coefficients respectively and adaptive iteration steps, we demonstrated the effectiveness of our proposed method in both phantom and mouse artery images. Comparison with other methods such as filtering method (mean, median filtering), wavelet method, probabilistic method and partial differential equation based methods in terms of peak signal-to-noise ratio (PSNR), equivalent number of looks (ENL) and contrast-to-noise ratio (CNR) showed the advantages of our method in reserving image energy and removing noise.

  9. Image fusion of microwave and optical remote sensing data for topographic map updating in the tropics

    Science.gov (United States)

    Pohl, Christine; van Genderen, John L.

    1995-11-01

    Temporal monitoring using remote sensing for topographic mapping requires continuous acquisition of image data. In many countries, but especially in the human Tropics, the heavy cloud cover is a major drawback for visible and infrared remote sensing. The research project presented in this paper uses the idea of integrating data from optical and microwave sensors using digital image fusion techniques to overcome the cloud cover problem. Additionally the combination of radar with optical data increases the interpretation capabilities and the reliability of the results due to the complementary nature of microwave and optical images. While optical data represents the reflectance of ground cover in visible and near-infrared, the radar is very sensitive to the shape, orientation, roughness and moisture content of the illuminated ground objects. This research investigates the geometric aspect of image fusion for topographic map updating. The paper describes experiences gained from an area in the north of The Netherlands (`Friesland') as calibration test site in comparison with first results from the research test site (`Bengkulu'), located on the south west coast of Sumatra in Indonesia. The data used for this investigated was acquired by SPOT, Landsat, ERS-1 and JERS-1.

  10. Fluorescent quantum dots: synthesis, biomedical optical imaging, and biosafety assessment.

    Science.gov (United States)

    Ji, Xiaoyuan; Peng, Fei; Zhong, Yiling; Su, Yuanyuan; He, Yao

    2014-12-01

    The marriage of nanomaterials with biology has significantly promoted advancement of biological techniques, profoundly facilitating basic research and practical applications in biological and biomedical fields. Taking advantages of unique optical properties (e.g., strong fluorescence, robust photostability, size-tunable emission wavelengths, etc.), fluorescent quantum dots (QDs), appearing as high-performance biological fluorescent nanoprobes, have been extensively explored for a variety of biomedical optical imaging applications. In this review, we present representative synthetic strategies for preparation of QDs and their applications in biomedical optical imaging, as well as risk assessments in vitro and in vivo. Briefly, we first summarize recent progress in fabrication of QDs via two rudimentary approaches, i.e., organometallic route and aqueous synthesis. Next we present representative achievement in QDs-based in vitro and in vivo biomedical optical imaging applications. We further discuss the toxicity assessment of QDs, ranging from cell studies to animal models. In the final section, we discuss challenges and perspectives for the QDs-relative bioapplications in the future.

  11. Imaging quality evaluation method of pixel coupled electro-optical imaging system

    Science.gov (United States)

    He, Xu; Yuan, Li; Jin, Chunqi; Zhang, Xiaohui

    2017-09-01

    With advancements in high-resolution imaging optical fiber bundle fabrication technology, traditional photoelectric imaging system have become ;flexible; with greatly reduced volume and weight. However, traditional image quality evaluation models are limited by the coupling discrete sampling effect of fiber-optic image bundles and charge-coupled device (CCD) pixels. This limitation substantially complicates the design, optimization, assembly, and evaluation image quality of the coupled discrete sampling imaging system. Based on the transfer process of grayscale cosine distribution optical signal in the fiber-optic image bundle and CCD, a mathematical model of coupled modulation transfer function (coupled-MTF) is established. This model can be used as a basis for following studies on the convergence and periodically oscillating characteristics of the function. We also propose the concept of the average coupled-MTF, which is consistent with the definition of traditional MTF. Based on this concept, the relationships among core distance, core layer radius, and average coupled-MTF are investigated.

  12. Fluorescence-enhanced imaging using a novel hand-held based optical imager: phantom studies

    Science.gov (United States)

    Ge, Jiajia; Zhu, Banghe; Regalado, Steven; Godavarty, Anuradha

    2008-02-01

    Near-infrared (NIR) optical imaging is an emerging noninvasive modality for breast cancer diagnosis. The currently available optical imaging systems towards tomography studies are limited either by instrument portability, patient comfort, or flexibility to image any given tissue volume. Hence, a novel hand-held probe based gain modulated intensified CCD camera imaging system is developed such that it can possibly overcome some of the above limitations. The unique features of this hand-held probe based optical imaging system are: (i) to perform simultaneous multiple point illumination and detection, thus decreasing the total imaging time and improving overall signal strength; (ii) to adapt to the tissue contours, thus decreasing the light leakage at contact surface; and (iii) to obtain trans-illumination measurements apart from reflectance measurements, thus improving the depth information. Phantom studies are performed to demonstrate the feasibility of performing fluorescence optical imaging under different target depths using cubical phantoms (10×6.5×10 cc). The effect of simultaneous multiple point illumination over sequential single point illumination is demonstrated from experimental phantom studies.

  13. Laser-jamming analysis of combined fiber lasers to imaging CCD

    Science.gov (United States)

    Jie, Xu; Shanghong, Zhao; Rui, Hou; Xiaoliang, Li; Jili, Wu; Yunxia, Li; Wen, Meng; Yanhui, Ni; Lihua, Ma

    2009-07-01

    To complete a successful laser jamming to imaging charge coupled device (CCD) based on combined fiber lasers, the interactions between CCD and combined fiber lasers were analyzed in detail. The saturation and crosstalk thresholds of CCD were achieved, which are lower than 10 mW/cm 2. Through theoretical analysis and numerical simulations, the thermal processes under single pulse, multi-pulses and continuous laser irradiations were developed. The simulation results have proved the possibility of hard damage caused by multi-pulses and continuous laser irradiations. The combined fiber lasers is suitable to deploy optical saturation jamming at present. The further applications of combined fiber lasers need a more powerful laser source and a more accurate tracking and pointing system.

  14. Serial Magnetization Transfer Imaging in Acute Optic Neuritis

    Science.gov (United States)

    Hickman, S. J.; Toosy, A. T.; Jones, S. J.; Altmann, D. R.; Miszkiel, K. A.; MacManus, D. G.; Barker, G. J.; Plant, G. T.; Thompson, A. J.; Miller, D.H.

    2004-01-01

    In serial studies of multiple sclerosis lesions, reductions in magnetization transfer ratio (MTR) are thought to be due to demyelination and axonal loss, with later rises due to remyelination. This study followed serial changes in MTR in acute optic neuritis in combination with clinical and electrophysiological measurements to determine if the MTR…

  15. Optical nano-imaging of gate-tunable graphene plasmons.

    Science.gov (United States)

    Chen, Jianing; Badioli, Michela; Alonso-González, Pablo; Thongrattanasiri, Sukosin; Huth, Florian; Osmond, Johann; Spasenović, Marko; Centeno, Alba; Pesquera, Amaia; Godignon, Philippe; Elorza, Amaia Zurutuza; Camara, Nicolas; García de Abajo, F Javier; Hillenbrand, Rainer; Koppens, Frank H L

    2012-07-05

    The ability to manipulate optical fields and the energy flow of light is central to modern information and communication technologies, as well as quantum information processing schemes. However, because photons do not possess charge, a way of controlling them efficiently by electrical means has so far proved elusive. A promising way to achieve electric control of light could be through plasmon polaritons—coupled excitations of photons and charge carriers—in graphene. In this two-dimensional sheet of carbon atoms, it is expected that plasmon polaritons and their associated optical fields can readily be tuned electrically by varying the graphene carrier density. Although evidence of optical graphene plasmon resonances has recently been obtained spectroscopically, no experiments so far have directly resolved propagating plasmons in real space. Here we launch and detect propagating optical plasmons in tapered graphene nanostructures using near-field scattering microscopy with infrared excitation light. We provide real-space images of plasmon fields, and find that the extracted plasmon wavelength is very short—more than 40 times smaller than the wavelength of illumination. We exploit this strong optical field confinement to turn a graphene nanostructure into a tunable resonant plasmonic cavity with extremely small mode volume. The cavity resonance is controlled in situ by gating the graphene, and in particular, complete switching on and off of the plasmon modes is demonstrated, thus paving the way towards graphene-based optical transistors. This successful alliance between nanoelectronics and nano-optics enables the development of active subwavelength-scale optics and a plethora of nano-optoelectronic devices and functionalities, such as tunable metamaterials, nanoscale optical processing, and strongly enhanced light–matter interactions for quantum devices and biosensing applications.

  16. Optical image encryption in Fresnel domain using spiral phase transform

    Science.gov (United States)

    Kumar, Ravi; Bhaduri, Basanta

    2017-09-01

    In this study, we propose a new nonlinear optical image encryption technique using spiral phase transform (SPT). First, the primary image is phase encoded and multiplied with a random amplitude mask (RAM), and using power function, the product is then powered to m. This powered output is Fresnel propagated with distance z 1 and then modulated with a random phase mask (RPM). The modulated image is further Fresnel propagated with distance z 2. Similarly, a security image is also modulated with another RAM and then Fresnel propagated with distance z 3. Next, the two modulated images after Fresnel propagations, are interfered and further Fresnel propagated with distance z 4 to get a complex image. Finally, this complex image is SPT with particular spiral phase function (SPF), to get the final encrypted image for transmission. In the proposed technique, the security keys are Fresnel propagation distances, the security image, RPM, RAMs, power order, m, and order of SPF, q. Numerical simulation results confirm the validity and effectiveness of the proposed technique. The proposed technique is robust against noise and brutal force attacks.

  17. Optical coherence tomography: imaging of the choroid and beyond.

    Science.gov (United States)

    Mrejen, Sarah; Spaide, Richard F

    2013-01-01

    Seventy percent of the blood flow to the eye goes to the choroid, a structure that is vitally important to the function of the retina. The in vivo structure of the choroid in health and disease is incompletely visualized with traditional imaging modalities, including indocyanine green angiography, ultrasonography, and spectral domain optical coherence tomography (OCT). Use of new OCT modalities, including enhanced depth imaging OCT, image averaging, and swept-source OCT, have led to increased visualization of the choroidal anatomy. The correlation of these new anatomical findings with other imaging modalities results increases understanding of many eye diseases and recognises of new ones. The status of the choroid appears to be a crucial determinant in the pathogenesis of diseases such as age-related choroidal atrophy, myopic chorioretinal atrophy, central serous chorioretinopathy, chorioretinal inflammatory diseases, and tumors. Extension of these imaging techniques has provided insights into abnormalities of the sclera and optic nerve. Future developments will include blood flow information, 3D rendering of various ocular structures, and the ability to evaluate changes in 3D structural information over time (4D imaging). Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Molecular imaging true-colour spectroscopic optical coherence tomography

    Science.gov (United States)

    Robles, Francisco E.; Wilson, Christy; Grant, Gerald; Wax, Adam

    2011-12-01

    Molecular imaging holds a pivotal role in medicine due to its ability to provide invaluable insight into disease mechanisms at molecular and cellular levels. To this end, various techniques have been developed for molecular imaging, each with its own advantages and disadvantages. For example, fluorescence imaging achieves micrometre-scale resolution, but has low penetration depths and is mostly limited to exogenous agents. Here, we demonstrate molecular imaging of endogenous and exogenous chromophores using a novel form of spectroscopic optical coherence tomography. Our approach consists of using a wide spectral bandwidth laser source centred in the visible spectrum, thereby allowing facile assessment of haemoglobin oxygen levels, providing contrast from readily available absorbers, and enabling true-colour representation of samples. This approach provides high spectral fidelity while imaging at the micrometre scale in three dimensions. Molecular imaging true-colour spectroscopic optical coherence tomography (METRiCS OCT) has significant implications for many biomedical applications including ophthalmology, early cancer detection, and understanding fundamental disease mechanisms such as hypoxia and angiogenesis.

  19. Satellite Imaging with Adaptive Optics on a 1 M Telescope

    Science.gov (United States)

    Bennet, F.; Price, I.; Rigaut, F.; Copeland, M.

    2016-09-01

    The Research School of Astronomy and Astrophysics at the Mount Stromlo Observatory in Canberra, Australia, have been developing adaptive optic (AO) systems for space situational awareness applications. We report on the development and demonstration of an AO system for satellite imaging using a 1 m telescope. The system uses the orbiting object as a natural guide star to measure atmospheric turbulence, and a deformable mirror to provide an optical correction. The AO system utilised modern, high speed and low noise EMCCD technology on both the wavefront sensor and imaging camera to achieve high performance, achieving a Strehl ratio in excess of 30% at 870 nm. Images are post processed with lucky imaging algorithms to further improve the final image quality. We demonstrate the AO system on stellar targets and Iridium satellites, achieving a near diffraction limited full width at half maximum. A specialised realtime controller allows our system to achieve a bandwidth above 100 Hz, with the wavefront sensor and control loop running at 2 kHz. The AO systems we are developing show how ground-based optical sensors can be used to manage the space environment. AO imaging systems can be used for satellite surveillance, while laser ranging can be used to determine precise orbital data used in the critical conjunction analysis required to maintain a safe space environment. We have focused on making this system compact, expandable, and versatile. We are continuing to develop this platform for other space situational awareness applications such as geosynchronous satellite astrometry, space debris characterisation, satellite imaging, and ground-to-space laser communication.

  20. Estimating Forest Aboveground Biomass by Combining Optical and SAR Data: A Case Study in Genhe, Inner Mongolia, China

    Directory of Open Access Journals (Sweden)

    Zhenfeng Shao

    2016-06-01

    Full Text Available Estimation of forest aboveground biomass is critical for regional carbon policies and sustainable forest management. Passive optical remote sensing and active microwave remote sensing both play an important role in the monitoring of forest biomass. However, optical spectral reflectance is saturated in relatively dense vegetation areas, and microwave backscattering is significantly influenced by the underlying soil when the vegetation coverage is low. Both of these conditions decrease the estimation accuracy of forest biomass. A new optical and microwave integrated vegetation index (VI was proposed based on observations from both field experiments and satellite (Landsat 8 Operational Land Imager (OLI and RADARSAT-2 data. According to the difference in interaction between the multispectral reflectance and microwave backscattering signatures with biomass, the combined VI (COVI was designed using the weighted optical optimized soil-adjusted vegetation index (OSAVI and microwave horizontally transmitted and vertically received signal (HV to overcome the disadvantages of both data types. The performance of the COVI was evaluated by comparison with those of the sole optical data, Synthetic Aperture Radar (SAR data, and the simple combination of independent optical and SAR variables. The most accurate performance was obtained by the models based on the COVI and optical and microwave optimal variables excluding OSAVI and HV, in combination with a random forest algorithm and the largest number of reference samples. The results also revealed that the predictive accuracy depended highly on the statistical method and the number of sample units. The validation indicated that this integrated method of determining the new VI is a good synergistic way to combine both optical and microwave information for the accurate estimation of forest biomass.

  1. Estimating Forest Aboveground Biomass by Combining Optical and SAR Data: A Case Study in Genhe, Inner Mongolia, China.

    Science.gov (United States)

    Shao, Zhenfeng; Zhang, Linjing

    2016-06-07

    Estimation of forest aboveground biomass is critical for regional carbon policies and sustainable forest management. Passive optical remote sensing and active microwave remote sensing both play an important role in the monitoring of forest biomass. However, optical spectral reflectance is saturated in relatively dense vegetation areas, and microwave backscattering is significantly influenced by the underlying soil when the vegetation coverage is low. Both of these conditions decrease the estimation accuracy of forest biomass. A new optical and microwave integrated vegetation index (VI) was proposed based on observations from both field experiments and satellite (Landsat 8 Operational Land Imager (OLI) and RADARSAT-2) data. According to the difference in interaction between the multispectral reflectance and microwave backscattering signatures with biomass, the combined VI (COVI) was designed using the weighted optical optimized soil-adjusted vegetation index (OSAVI) and microwave horizontally transmitted and vertically received signal (HV) to overcome the disadvantages of both data types. The performance of the COVI was evaluated by comparison with those of the sole optical data, Synthetic Aperture Radar (SAR) data, and the simple combination of independent optical and SAR variables. The most accurate performance was obtained by the models based on the COVI and optical and microwave optimal variables excluding OSAVI and HV, in combination with a random forest algorithm and the largest number of reference samples. The results also revealed that the predictive accuracy depended highly on the statistical method and the number of sample units. The validation indicated that this integrated method of determining the new VI is a good synergistic way to combine both optical and microwave information for the accurate estimation of forest biomass.

  2. The Infrared Imaging Spectrograph (IRIS) for TMT: optical design of IRIS imager with "co-axis double TMA"

    Science.gov (United States)

    Tsuzuki, Toshihiro; Suzuki, Ryuji; Harakawa, Hiroki; Ikenoue, Bungo; Larkin, James; Moore, Anna; Obuchi, Yoshiyuki; Phillips, Andrew C.; Saito, Sakae; Uraguchi, Fumihiro; Wincentsen, James; Wright, Shelley; Hayano, Yutaka

    2016-08-01

    IRIS (InfraRed Imaging Spectrograph) is one of the first-generation instruments for the Thirty Meter Telescope (TMT). IRIS is composed of a combination of near-infrared (0.84-2.4 μm) diffraction limited imager and integral field spectrograph. To achieve near-diffraction limited resolutions in the near-infrared wavelength region, IRIS uses the advanced adaptive optics system NFIRAOS (Narrow Field Infrared Adaptive Optics System) and integrated on-instrument wavefront sensors (OIWFS). However, IRIS itself has challenging specifications. First, the overall system wavefront error should be less than 40 nm in Y, z, J, and H-band and 42 nm in K-band over a 34.0 × 34.0 arcsecond field of view. Second, the throughput of the imager components should be more than 42 percent. To achieve the extremely low wavefront error and high throughput, all reflective design has been newly proposed. We have adopted a new design policy called "Co-Axis double-TMA", which cancels the asymmetric aberrations generated by "collimator/TMA" and "camera/TMA" efficiently. The latest imager design meets all specifications, and, in particular, the wavefront error is less than 17.3 nm and throughput is more than 50.8 percent. However, to meet the specification of wavefront error and throughput as built performance, the IRIS imager requires both mirrors with low surface irregularity after high-reflection coating in cryogenic and high-level Assembly Integration and Verification (AIV). To deal with these technical challenges, we have done the tolerance analysis and found that total pass rate is almost 99 percent in the case of gauss distribution and more than 90 percent in the case of parabolic distribution using four compensators. We also have made an AIV plan and feasibility check of the optical elements. In this paper, we will present the details of this optical system.

  3. Combined photoacoustic and ultrasound imaging of human breast in vivo in the mammographic geometry

    Science.gov (United States)

    Xie, Zhixing; Lee, Won-Mean; Hooi, Fong Ming; Fowlkes, J. Brian; Pinsky, Renee W.; Mueller, Dean; Wang, Xueding; Carson, Paul L.

    2013-03-01

    This photoacoustic volume imaging (PAVI) system is designed to study breast cancer detection and diagnosis in the mammographic geometry in combination with automated 3D ultrasound (AUS). The good penetration of near-infrared (NIR) light and high receiving sensitivity of a broad bandwidth, 572 element, 2D PVDF array at a low center-frequency of 1MHz were utilized with 20 channel simultaneous acquisition. The feasibility of this system in imaging optically absorbing objects in deep breast tissues was assessed first through experiments on ex vivo whole breasts. The blood filled pseudo lesions were imaged at depths up to 49 mm in the specimens. In vivo imaging of human breasts has been conducted. 3D PAVI image stacks of human breasts were coregistered and compared with 3D ultrasound image stacks of the same breasts. Using the designed system, PAVI shows satisfactory imaging depth and sensitivity for coverage of the entire breast when imaged from both sides with mild compression in the mammographic geometry. With its unique soft tissue contrast and excellent sensitivity to the tissue hemodynamic properties of fractional blood volume and blood oxygenation, PAVI, as a complement to 3D ultrasound and digital tomosynthesis mammography, might well contribute to detection, diagnosis and prognosis for breast cancer.

  4. Improved cardiac motion detection from ultrasound images using TDIOF: a combined B-mode/ tissue Doppler approach

    Science.gov (United States)

    Tavakoli, Vahid; Stoddard, Marcus F.; Amini, Amir A.

    2013-03-01

    Quantitative motion analysis of echocardiographic images helps clinicians with the diagnosis and therapy of patients suffering from cardiac disease. Quantitative analysis is usually based on TDI (Tissue Doppler Imaging) or speckle tracking. These methods are based on two independent techniques - the Doppler Effect and image registration, respectively. In order to increase the accuracy of the speckle tracking technique and cope with the angle dependency of TDI, herein, a combined approach dubbed TDIOF (Tissue Doppler Imaging Optical Flow) is proposed. TDIOF is formulated based on the combination of B-mode and Doppler energy terms in an optical flow framework and minimized using algebraic equations. In this paper, we report on validations with simulated, physical cardiac phantom, and in-vivo patient data. It is shown that the additional Doppler term is able to increase the accuracy of speckle tracking, the basis for several commercially available echocardiography analysis techniques.

  5. Dynamic fluorescence lifetime imaging based on acousto-optic deflectors

    Science.gov (United States)

    Yan, Wei; Peng, Xiao; Qi, Jing; Gao, Jian; Fan, Shunping; Wang, Qi; Qu, Junle; Niu, Hanben

    2014-11-01

    We report a dynamic fluorescence lifetime imaging (D-FLIM) system that is based on a pair of acousto-optic deflectors for the random regions of interest (ROI) study in the sample. The two-dimensional acousto-optic deflector devices are used to rapidly scan the femtosecond excitation laser beam across the sample, providing specific random access to the ROI. Our experimental results using standard fluorescent dyes in live cancer cells demonstrate that the D-FLIM system can dynamically monitor the changing process of the microenvironment in the ROI in live biological samples.

  6. Raman imaging of biofilms using gold sputtered fiber optic probes

    Science.gov (United States)

    Christopher, Christina Grace Charlet; Manoharan, Hariharan; Subrahmanyam, Aryasomayajula; Sai, V. V. Raghavendra

    2016-12-01

    In this work we report characterization of bacterial biofilm using gold sputtered optical fiber probe as substrates for confocal Raman spectroscopy measurements. The chemical composition and the heterogeneity of biofilms in the extracellular polymeric substances (EPS) was evaluated. The spatial distribution of bacterial biofilm on the substrates during their growth phase was studied using Raman imaging. Further, the influence of substrate's surface on bacterial adhesion was investigated by studying growth of biofilms on surfaces with hydrophilic and hydrophobic coatings. This study validates the use of gold sputtered optical fiber probes as SERS substrates in confocal microscopic configuration to identify and characterize clinically relevant biofilms.

  7. Three-dimensional multifunctional optical coherence tomography for skin imaging

    Science.gov (United States)

    Li, En; Makita, Shuichi; Hong, Young-Joo; Kasaragod, Deepa; Sasaoka, Tomoko; Yamanari, Masahiro; Sugiyama, Satoshi; Yasuno, Yoshiaki

    2016-02-01

    Optical coherence tomography (OCT) visualizes cross-sectional microstructures of biological tissues. Recent developments of multifunctional OCT (MF-OCT) provides multiple optical contrasts which can reveal currently unknown tissue properties. In this contribution we demonstrate multifunctional OCT specially designed for dermatological investigation. And by utilizing it to measure four different body parts of in vivo human skin, three-dimensional scattering OCT, OCT angiography, polarization uniformity tomography, and local birefringence tomography images were obtained by a single scan. They respectively contrast the structure and morphology, vasculature, melanin content and collagen traits of the tissue.

  8. Phi optics: from image to knowledge (Conference Presentation)

    Science.gov (United States)

    Chiritescu, Catalin

    2016-03-01

    Optical microscopy of live cells and tissues provides the main insight for life science researchers in academia and bio-pharma. The cells have very small features, are transparent, and require long term observations (hours to days) to measure the effects of drugs and diseases. New technologies - under the umbrella term of Quantitative Phase Imaging (QPI) - have come to light in the past decade to challenge and complement the current state of the art solutions that use fluorophores. Phi Optics talk will outline their lessons learned in the process of bringing an academic idea to the commercial space.

  9. Optical coherence tomography for retinal imaging in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Zimmermann H

    2014-12-01

    Full Text Available Hanna Zimmermann,1 Timm Oberwahrenbrock,1 Alexander U Brandt,1 Friedemann Paul,1–3 Jan Dörr1,2 1NeuroCure Clinical Research Center, 2Clinical and Experimental Multiple Sclerosis Research Center, 3Department of Neurology, Charité – Universitätsmedizin Berlin, Berlin, Germany Abstract: Visual disturbances caused by inflammatory and demyelinating processes of the visual system, mainly in the optic nerve, are a common symptom in multiple sclerosis (MS. Optical coherence tomography (OCT is a tool that is increasingly used for quantifying retinal damage in MS and other neurologic diseases. Based on spectral interferometry, it uses low-coherent infrared light to generate high-resolution spatial images of the retina. The retinal nerve fiber layer (RNFL consists of unmyelinated axons that form the optic nerve, and thus represents a part of the central nervous system. OCT allows for noninvasive measurements of RNFL thickness in micrometer resolution. With the help of OCT, researchers have managed to demonstrate that eyes of MS patients show distinct RNFL thinning after an event of acute optic neuritis in MS, and even subclinical damage in eyes with no previous optic neuritis. OCT is also a useful tool in terms of providing a differential diagnosis of MS toward, for example, neuromyelitis optica, a disease that usually shows stronger retinal thinning, or Susac syndrome, which is characterized by distinct patchy thinning of the inner retinal layers. RNFL thinning is associated with magnetic resonance imaging-derived measurements of the brain, such as whole-brain atrophy, gray and white matter atrophy, and optic radiation damage. These features suggest that OCT-derived retinal measurements are a complement for measuring central nervous system neurodegeneration in the context of clinical trials – for example, with neuroprotective substances. Keywords: visual function, multiple sclerosis, optic neuritis, retinal nerve fiber layer, neuromyelitis optica

  10. Ultrafast superresolution fluorescence imaging with spinning disk confocal microscope optics.

    Science.gov (United States)

    Hayashi, Shinichi; Okada, Yasushi

    2015-05-01

    Most current superresolution (SR) microscope techniques surpass the diffraction limit at the expense of temporal resolution, compromising their applications to live-cell imaging. Here we describe a new SR fluorescence microscope based on confocal microscope optics, which we name the spinning disk superresolution microscope (SDSRM). Theoretically, the SDSRM is equivalent to a structured illumination microscope (SIM) and achieves a spatial resolution of 120 nm, double that of the diffraction limit of wide-field fluorescence microscopy. However, the SDSRM is 10 times faster than a conventional SIM because SR signals are recovered by optical demodulation through the stripe pattern of the disk. Therefore a single SR image requires only a single averaged image through the rotating disk. On the basis of this theory, we modified a commercial spinning disk confocal microscope. The improved resolution around 120 nm was confirmed with biological samples. The rapid dynamics of micro-tubules, mitochondria, lysosomes, and endosomes were observed with temporal resolutions of 30-100 frames/s. Because our method requires only small optical modifications, it will enable an easy upgrade from an existing spinning disk confocal to a SR microscope for live-cell imaging. © 2015 Hayashi and Okada. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  11. Imaging of the Macula Indicates Early Completion of Structural Deficit in Autosomal-Dominant Optic Atrophy

    DEFF Research Database (Denmark)

    Rönnbäck, Cecilia; Milea, Dan; Larsen, Michael

    2013-01-01

    Optical coherence tomography (OCT) enables 3-dimensional imaging of the retina, including the layer of ganglion cells that supplies the optic nerve with its axons. We tested OCT as means of diagnosing and phenotyping autosomal-dominant optic atrophy (ADOA).......Optical coherence tomography (OCT) enables 3-dimensional imaging of the retina, including the layer of ganglion cells that supplies the optic nerve with its axons. We tested OCT as means of diagnosing and phenotyping autosomal-dominant optic atrophy (ADOA)....

  12. Combination of principal component analysis and optical-flow motion compensation for improved cardiac MR thermometry

    Science.gov (United States)

    Toupin, S.; de Senneville, B. Denis; Ozenne, V.; Bour, P.; Lepetit-Coiffe, M.; Boissenin, M.; Jais, P.; Quesson, B.

    2017-02-01

    The use of magnetic resonance (MR) thermometry for the monitoring of thermal ablation is rapidly expanding. However, this technique remains challenging for the monitoring of the treatment of cardiac arrhythmia by radiofrequency ablation due to the heart displacement with respiration and contraction. Recent studies have addressed this problem by compensating in-plane motion in real-time with optical-flow based tracking technique. However, these algorithms are sensitive to local variation of signal intensity on magnitude images associated with tissue heating. In this study, an optical-flow algorithm was combined with a principal component analysis method to reduce the impact of such effects. The proposed method was integrated to a fully automatic cardiac MR thermometry pipeline, compatible with a future clinical workflow. It was evaluated on nine healthy volunteers under free breathing conditions, on a phantom and in vivo on the left ventricle of a sheep. The results showed that local intensity changes in magnitude images had lower impact on motion estimation with the proposed method. Using this strategy, the temperature mapping accuracy was significantly improved.

  13. Combined electromechanical impedance and fiber optic diagnosis of aerospace structures

    Science.gov (United States)

    Schlavin, Jon; Zagrai, Andrei; Clemens, Rebecca; Black, Richard J.; Costa, Joey; Moslehi, Behzad; Patel, Ronak; Sotoudeh, Vahid; Faridian, Fereydoun

    2014-03-01

    Electromechanical impedance is a popular diagnostic method for assessing structural conditions at high frequencies. It has been utilized, and shown utility, in aeronautic, space, naval, civil, mechanical, and other types of structures. By contrast, fiber optic sensing initially found its niche in static strain measurement and low frequency structural dynamic testing. Any low frequency limitations of the fiber optic sensing, however, are mainly governed by its hardware elements. As hardware improves, so does the bandwidth (frequency range * number of sensors) provided by the appropriate enabling fiber optic sensor interrogation system. In this contribution we demonstrate simultaneous high frequency measurements using fiber optic and electromechanical impedance structural health monitoring technologies. A laboratory specimen imitating an aircraft wing structure, incorporating surfaces with adjustable boundary conditions, was instrumented with piezoelectric and fiber optic sensors. Experiments were conducted at different structural boundary conditions associated with deterioration of structural health. High frequency dynamic responses were collected at multiple locations on a laboratory wing specimen and conclusions were drawn about correspondence between structural damage and dynamic signatures as well as correlation between electromechanical impedance and fiber optic sensors spectra. Theoretical investigation of the effect of boundary conditions on electromechanical impedance spectra is presented and connection to low frequency structural dynamics is suggested. It is envisioned that acquisition of high frequency structural dynamic responses with multiple fiber optic sensors may open new diagnostic capabilities for fiber optic sensing technologies.

  14. A combined nulling and imaging pupil-plane beam-combiner for DARWIN

    NARCIS (Netherlands)

    Haaksman, R.P.H.; Vries, C.P. de; Herder, J.-W. den; Vosteen, L.L.A.; Bokhove, H.; Mieremet, A.L.

    2006-01-01

    The primary goal of DARWIN is to detect earth-like extrasolar planets and to search for biomarkers. This is achieved by means of nulling interferometry, using three free-flying telescopes and a Beam-Combiner (BC) hub. DARWIN will be able to perform astrophysical imaging with high spectral and spatia

  15. Joint Change Detection and Image Registration for Optical Remote Sensing Images

    Directory of Open Access Journals (Sweden)

    Wang Luo

    2012-03-01

    Full Text Available In this letter, a novel method is proposed for jointly unsupervised change detection and image registration over multi-temporal optical remote sensing images. An iterative energy minimization scheme is employed to extract the pixel opacity. Specifically, we extract the consistent points which provide the initial seed nodes and the feature nodes for random walker image segmentation and image registration, respectively. And the seed nodes will be updated according to the analysis of the changed and unchanged regions. Experimental results demonstrate that the proposed method can perform change detection as well as the state of the art methods. In particular, it can perform change detection rapidly and automatically over unregistered optical remote sensing images.

  16. VISION: A Six-Telescope Fiber-Fed Visible Light Beam Combiner for the Navy Precision Optical Interferometer

    CERN Document Server

    Garcia, Eugenio V; van Belle, Gerard; Monnier, John D; Stassun, Keivan G; Ghasempour, Askari; Clark, James H; Zavala, R T; Benson, James A; Hutter, Donald J; Schmitt, Henrique R; Baines, Ellyn K; Jorgensen, Anders M; Strosahl, Susan G; Sanborn, Jason; Zawicki, Stephen J; Sakosky, Michael F; Swihart, Samuel

    2016-01-01

    Visible-light long baseline interferometry holds the promise of advancing a number of important applications in fundamental astronomy, including the direct measurement of the angular diameters and oblateness of stars, and the direct measurement of the orbits of binary and multiple star systems. To advance, the field of visible-light interferometry requires development of instruments capable of combining light from 15 baselines (6 telescopes) simultaneously. The Visible Imaging System for Interferometric Observations at NPOI (VISION) is a new visible light beam combiner for the Navy Precision Optical Interferometer (NPOI) that uses single-mode fibers to coherently combine light from up to six telescopes simultaneously with an image-plane combination scheme. It features a photometric camera for calibrations and spatial filtering from single-mode fibers with two Andor Ixon electron multiplying CCDs. This paper presents the VISION system, results of laboratory tests, and results of commissioning on-sky observatio...

  17. Intraocular lens alignment from an en face optical coherence tomography image Purkinje-like method

    Science.gov (United States)

    Sun, Mengchan; de Castro, Alberto; Ortiz, Sergio; Perez-Merino, Pablo; Birkenfeld, Judith; Marcos, Susana

    2014-06-01

    Measurement of intraocular lens (IOL) alignment implanted in patients in cataract surgery is important to understand their optical performance. We present a method to estimate tilt and decentration of IOLs based on optical coherence tomography (OCT) images. En face OCT images show Purkinje-like images that correspond to the specular reflections from the corneal and IOL surfaces. Unlike in standard Purkinje-imaging, the tomographic nature of OCT allows unequivocal association of the reflection with the corresponding surface. The locations of the Purkinje-like images are linear combinations of IOL tilt, IOL decentration, and eye rotation. The weighting coefficients depend on the individual anterior segment geometry, obtained from the same OCT datasets. The methodology was demonstrated on an artificial model eye with set amounts of lens tilt and decentration and five pseudophakic eyes. Measured tilt and decentration in the artificial eye differed by 3.7% and 0.9%, respectively, from nominal values. In patients, average IOL tilt and decentration from Purkinje were 3.30±4.68 deg and 0.16±0.16 mm, respectively, and differed on average by 0.5 deg and 0.09 mm, respectively, from direct measurements on distortion-corrected OCT images. Purkinje-based methodology from anterior segment en face OCT imaging provided, therefore, reliable measurements of IOL tilt and decentration.

  18. Optical color-image encryption in the diffractive-imaging scheme

    Science.gov (United States)

    Qin, Yi; Wang, Zhipeng; Pan, Qunna; Gong, Qiong

    2016-02-01

    By introducing the theta modulation technique into the diffractive-imaging-based optical scheme, we propose a novel approach for color image encryption. For encryption, a color image is divided into three channels, i.e., red, green and blue, and thereafter these components are appended by redundant data before being sent to the encryption scheme. The carefully designed optical setup, which comprises of three 4f optical architectures and a diffractive-imaging-based optical scheme, could encode the three plaintexts into a single noise-like intensity pattern. For the decryption, an iterative phase retrieval algorithm, together with a filter operation, is applied to extract the primary color images from the diffraction intensity map. Compared with previous methods, our proposal has successfully encrypted a color rather than grayscale image into a single intensity pattern, as a result of which the capacity and practicability have been remarkably enhanced. In addition, the performance and the security of it are also investigated. The validity as well as feasibility of the proposed method is supported by numerical simulations.

  19. Optical coherence tomography for embryonic imaging: a review

    Science.gov (United States)

    Raghunathan, Raksha; Singh, Manmohan; Dickinson, Mary E.; Larin, Kirill V.

    2016-05-01

    Embryogenesis is a highly complex and dynamic process, and its visualization is crucial for understanding basic physiological processes during development and for identifying and assessing possible defects, malformations, and diseases. While traditional imaging modalities, such as ultrasound biomicroscopy, micro-magnetic resonance imaging, and micro-computed tomography, have long been adapted for embryonic imaging, these techniques generally have limitations in their speed, spatial resolution, and contrast to capture processes such as cardiodynamics during embryogenesis. Optical coherence tomography (OCT) is a noninvasive imaging modality with micrometer-scale spatial resolution and imaging depth up to a few millimeters in tissue. OCT has bridged the gap between ultrahigh resolution imaging techniques with limited imaging depth like confocal microscopy and modalities, such as ultrasound sonography, which have deeper penetration but poorer spatial resolution. Moreover, the noninvasive nature of OCT has enabled live imaging of embryos without any external contrast agents. We review how OCT has been utilized to study developing embryos and also discuss advances in techniques used in conjunction with OCT to understand embryonic development.

  20. Label-free imaging through nonlinear optical signals

    Directory of Open Access Journals (Sweden)

    Ling Tong

    2011-06-01

    Full Text Available Strong intrinsic nonlinear optical (NLO signals not only make nanostructures promising agents for bio-imaging, but also advance NLO microscopy for the study of interactions between nanomaterials and live cells. Single beam modalities such as multiphoton luminescence, second harmonic generation, and third harmonic generation provide a simple way to probe many types of nanostructures. As for more advanced modalities, photothermal heterodyne imaging provides improved detection sensitivity for smaller objects, and transient absorption microscopy provides structural information to distinguish metal from semiconducting carbon nanotubes, and eumelanin from pheomelanin. The four-wave mixing signal achieves chemical selectivity in the presence of either vibrational or electronic resonance, as used in coherent Raman scattering imaging of molecules and in electronically resonance enhanced four-wave mixing imaging of nanostructures.