WorldWideScience

Sample records for combined accelerated external

  1. Attitude Estimation Using Kalman Filtering: External Acceleration Compensation Considerations

    Directory of Open Access Journals (Sweden)

    Romy Budhi Widodo

    2016-01-01

    Full Text Available Attitude estimation is often inaccurate during highly dynamic motion due to the external acceleration. This paper proposes extended Kalman filter-based attitude estimation using a new algorithm to overcome the external acceleration. This algorithm is based on an external acceleration compensation model to be used as a modifying parameter in adjusting the measurement noise covariance matrix of the extended Kalman filter. The experiment was conducted to verify the estimation accuracy, that is, one-axis and multiple axes sensor movement. Five approaches were used to test the estimation of the attitude: (1 the KF-based model without compensating for external acceleration, (2 the proposed KF-based model which employs the external acceleration compensation model, (3 the two-step KF using weighted-based switching approach, (4 the KF-based model which uses the threshold-based approach, and (5 the KF-based model which uses the threshold-based approach combined with a softened part approach. The proposed algorithm showed high effectiveness during the one-axis test. When the testing conditions employed multiple axes, the estimation accuracy increased using the proposed approach and exhibited external acceleration rejection at the right timing. The proposed algorithm has fewer parameters that need to be set at the expense of the sharpness of signal edge transition.

  2. Proton external beam in the TANDAR Accelerator

    International Nuclear Information System (INIS)

    Rey, R.; Schuff, J.A.; Perez de la Hoz, A.; Debray, M.E.; Hojman, D.; Kreiner, A.J.; Kesque, J.M.; Saint-Martin, G.; Oppezzo, O.; Bernaola, O.A.; Molinari, B.L.; Duran, H.A.; Policastro, L.; Palmieri, M.; Ibanez, J.; Stoliar, P.; Mazal, A.; Caraballo, M.E.; Burlon, A.; Cardona, M.A.; Vazquez, M.E.; Salfity, M.F.; Ozafran, M.J.; Naab, F.; Levinton, G.; Davidson, M.; Buhler, M.

    1998-01-01

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm 2 approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  3. Plasma cluster acceleration by means of external magnetic fields

    International Nuclear Information System (INIS)

    Kracik, J.; Maloch, J.; Sobra, K.

    1975-01-01

    The electromagnetic shock tubes are used not only for shock wave creation and study but also for pulse plasma acceleration. By applying the rail acceleration the external magnetic field perpendicular to the plasma cluster velocity can be increased. In the present work is theoretically and experimentally confirmed the external magnetic field influence on the plasma cluster acceleration when the 'snow plough' model is used. (Auth.)

  4. Towards external injection in laser wakefield acceleration

    NARCIS (Netherlands)

    Stragier, X.F.D.

    2011-01-01

    In laser wakefield acceleration (LWA) a plasma wave is driven by a high intensity ultra short laser pulse and the longitudinal electric fields in the plasma wave are used to accelerate electron bunches. Electrons with an appropriate kinetic energy, injected on the right phase of the plasma wave, get

  5. Combining Teacher Assessment Scores with External Examination ...

    African Journals Online (AJOL)

    Combining Teacher Assessment Scores with External Examination Scores for Certification: Comparative Study of Four Statistical Models. ... University entrance examination scores in mathematics were obtained for a subsample of 115 ...

  6. Combined effect of external and internal irradiation

    International Nuclear Information System (INIS)

    Kiradzhiev, G.

    1987-01-01

    Some of the general regularities of the combined effect of external irradiation and iodine 131 are discussed. Data are adduced showing that modification of the effects of these two radiation factors, when jointly applied, is also determined by the quantitative relations of the applied doses of external and internal irradiation, referred to a particular moment of the effects. It was shown that the effects of the radionuclides in these combined radiation injuries are basically realized by two mechanisms: 1. changes are found in the radionuclide kinetic parameters (nonspecific effects); 2. changes in their kinetic parameters are absent (specific effect). These two mechanisms underlie different approaches to therapy

  7. External radiation exposure control system in accelerator facilities

    International Nuclear Information System (INIS)

    Ogawa, Tatsuhiko; Iimoto, Takeshi; Kosako, Toshiso

    2011-01-01

    The external exposure control systems in KEK and CERN are discussed to find out good practices and unreasonableness of radiation control in accelerator facilities, which plays an important role in optimizing national and/or site specific radiological regulations, referring to relevant ICRP publications. Personal dose limits and radiation area classifications were analyzed and their reasonableness were explored. Good example of supervised areas, area classification based on realistic assumptions on working time etc are found. On the other hand, unreasonable systems, that are often attributed to the national regulation or ideas presented in the old publications are also found. (author)

  8. Dirac vacuum: Acceleration and external-field effects

    International Nuclear Information System (INIS)

    Jauregui, R.; Torres, M.; Hacyan, S.

    1991-01-01

    The quantization of the massive spin-1/2 field in Rindler coordinates is considered, including the effects of a background magnetic field. We calculate the expectation values of conserved quantities such as the stress-energy tensor, current density, and spin distribution, as detected by an accelerated observer. The ratio of the energy and particle densities is given by a Fermi-Dirac distribution, but the spectrum of these quantities takes in general a complicated form that cannot be simply interpreted as a thermal spectrum. For the free-particle case the spectrum of the energy-stress tensor has a Fermi-Dirac form only in the massless limit. In the presence of the magnetic field the Dirac vacuum is magnetized and exhibits plasmalike properties

  9. External radiotherapy. Particle accelerator - Radiation protection: medical sheet ED 4246

    International Nuclear Information System (INIS)

    2007-06-01

    After having indicated the required authorizations for the use of external radiotherapy installations, this document presents the various aspects and measures related to radiation protection of workers when performing such treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks

  10. Tumor bed delineation for external beam accelerated partial breast irradiation: A systematic review

    International Nuclear Information System (INIS)

    Yang, T. Jonathan; Tao, Randa; Elkhuizen, Paula H.M.; Vliet-Vroegindeweij, Corine van; Li, Guang; Powell, Simon N.

    2013-01-01

    In recent years, accelerated partial breast irradiation (APBI) has been considered an alternative to whole breast irradiation for patients undergoing breast-conserving therapy. APBI delivers higher doses of radiation in fewer fractions to the post-lumpectomy tumor bed with a 1–2 cm margin, targeting the area at the highest risk of local recurrence while sparing normal breast tissue. However, there are inherent challenges in defining accurate target volumes for APBI. Studies have shown that significant interobserver variation exists among radiation oncologists defining the lumpectomy cavity, which raises the question of how to improve the accuracy and consistency in the delineation of tumor bed volumes. The combination of standardized guidelines and surgical clips significantly improves an observer’s ability in delineation, and it is the standard in multiple ongoing external-beam APBI trials. However, questions about the accuracy of the clips to mark the lumpectomy cavity remain, as clips only define a few points at the margin of the cavity. This paper reviews the techniques that have been developed so far to improve target delineation in APBI delivered by conformal external beam radiation therapy, including the use of standardized guidelines, surgical clips or fiducial markers, pre-operative computed tomography imaging, and additional imaging modalities, including magnetic resonance imaging, ultrasound imaging, and positron emission tomography/computed tomography. Alternatives to post-operative APBI, future directions, and clinical recommendations were also discussed

  11. Linear induction accelerators made from pulse-line cavities with external pulse injection

    International Nuclear Information System (INIS)

    Smith, I.

    1979-01-01

    Two types of linear induction accelerator have been reported previously. In one, unidirectional voltage pulses are generated outside the accelerator and injected into the accelerator cavity modules, which contain ferromagnetic material to reduce energy losses in the form of currents induced, in parallel with the beam, in the cavity structure. In the other type, the accelerator cavity modules are themselves pulse-forming lines with energy storage and switches; parallel current losses are made zero by the use of circuits that generate bidirectional acceleration waveforms with a zero voltage-time integral. In a third type of design described here, the cavities are externally driven, and 100% efficient coupling of energy to the beam is obtained by designing the external pulse generators to produce bidirectional voltage waveforms with zero voltage-time integral. A design for such a pulse generator is described that is itself one hundred percent efficient and which is well suited to existing pulse power techniques. Two accelerator cavity designs are described that can couple the pulse from such a generator to the beam; one of these designs provides voltage doubling. Comparison is made between the accelerating gradients that can be obtained with this and the preceding types of induction accelerator

  12. Method for accelerated aging under combined environmental stress conditions

    International Nuclear Information System (INIS)

    Gillen, K.T.

    1979-01-01

    An accelerated aging method which can be used to simulate aging in combined stress environment situations is described. It is shown how the assumptions of the method can be tested experimentally. Aging data for a chloroprene cable jacketing material in single and combined radiation and temperature environments are analyzed and it is shown that these data offer evidence for the validity of the method

  13. Improving external beam radiotherapy by combination with internal irradiation.

    Science.gov (United States)

    Dietrich, A; Koi, L; Zöphel, K; Sihver, W; Kotzerke, J; Baumann, M; Krause, M

    2015-07-01

    The efficacy of external beam radiotherapy (EBRT) is dose dependent, but the dose that can be applied to solid tumour lesions is limited by the sensitivity of the surrounding tissue. The combination of EBRT with systemically applied radioimmunotherapy (RIT) is a promising approach to increase efficacy of radiotherapy. Toxicities of both treatment modalities of this combination of internal and external radiotherapy (CIERT) are not additive, as different organs at risk are in target. However, advantages of both single treatments are combined, for example, precise high dose delivery to the bulk tumour via standard EBRT, which can be increased by addition of RIT, and potential targeting of micrometastases by RIT. Eventually, theragnostic radionuclide pairs can be used to predict uptake of the radiotherapeutic drug prior to and during therapy and find individual patients who may benefit from this treatment. This review aims to highlight the outcome of pre-clinical studies on CIERT and resultant questions for translation into the clinic. Few clinical data are available until now and reasons as well as challenges for clinical implementation are discussed.

  14. Tic-Tac: Accelerating a Skateboard from Rest without Touching an External Support

    Science.gov (United States)

    Kunesch, M.; Usunov, A.

    2010-01-01

    This paper outlines the solution that the Team of Austria found to problem number 7, "skateboarder", presented in the finals of the 22nd International Young Physicists' Tournament (IYPT) in Tianjin, China. We investigated how a skateboarder can accelerate from rest on a horizontal surface without touching an external support. The focus was laid on…

  15. Energy Efficiency of an Intracavity Coupled, Laser-Driven Linear Accelerator Pumped by an External Laser

    International Nuclear Information System (INIS)

    Neil Na, Y.C.; Siemann, R.H.; SLAC; Byer, R.L.; Stanford U., Phys. Dept.

    2005-01-01

    We calculate the optimum energy efficiency of a laser-driven linear accelerator by adopting a simple linear model. In the case of single bunch operation, the energy efficiency can be enhanced by incorporating the accelerator into a cavity that is pumped by an external laser. In the case of multiple bunch operation, the intracavity configuration is less advantageous because the strong wakefield generated by the electron beam is also recycled. Finally, the calculation indicates that the luminosity of a linear collider based on such a structure is comparably small if high efficiency is desired

  16. Acceleration/vibration combined environment activities. Interim report

    International Nuclear Information System (INIS)

    Shuman, R.L.

    1980-01-01

    The combining of two environments, i.e., linear acceleration and vibration, for use in laboratory testing to determine the damage to some mechanical devices when simultaneously subjected to these two environments, is discussed. The use of a Genisco centrifuge with an Unholtz-Dickie vibration machine mounted on it is described. Initial efforts at operating a shaker on the centrifuge have not been completely successful, so modifications to the system are being made

  17. Combined external beam and intraluminal radiotherapy for irresectable Klatskin tumors

    Energy Technology Data Exchange (ETDEWEB)

    Schleicher, U.M. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); Staatz, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Alzen, G. [Klinik fuer Radiologische Diagnostik, Technische Hochschule Aachen (Germany); Abt. Kinderradiologie, Giessen Univ. (Germany); Andreopoulos, D. [Klinik fuer Strahlentherapie, Technische Hochschule Aachen (Germany); BOC Oncology Centre, Nikosia (Cyprus)

    2002-12-01

    Background: In most cases of proximal cholangiocarcinoma, curative surgery is not possible. Radiotherapy can be used for palliative treatment. We report our experience with combined external beam and intraluminal radiotherapy of advanced Klatskin's tumors. Patients and Methods: 30 patients were treated for extrahepatic proximal bile duct cancer. Our schedule consisted for external beam radiotherapy (median dose 30 Gy) and a high-dose-rate brachytherapy boost (median dose 40 Gy) delivered in four or five fractions, which could be applied completely in twelve of our patients. 15 patients in the brachytherapy and nine patients in the non-brachytherapy group received additional low-dose chemotherapy with 5-fluorouracil. Results: The brachytherapy boost dose improved the effect of external beam radiotherapy by increasing survival from a median of 3.9 months in the non-brachytherapy group to 9.1 months in the brachytherapy group. The effect was obvious in patients receiving a brachytherapy dose above 30 Gy, and in those without jaundice at the beginning of radiotherapy (p<0.05). Conclusions: The poor prognosis in patients with advanced Klatskin's tumors may be improved by combination therapy, with the role of brachytherapy and chemotherapy still to be defined. Our results suggest that patients without jaundice should be offered brachytherapy, and that a full dose of more than 30 Gy should be applied. (orig.) [German] Hintergrund: Bei den meisten Patienten mit proximalen Cholangiokarzinomen ist eine kurative Operation nicht mehr moeglich. Im Rahmen der Palliativbehandlung kann die Strahlentherapie eingesetzt werden. Wir berichten ueber unsere Erfahrungen mit der Kombination aus perkutaner und intraluminaler Strahlentherapie fortgeschrittener Klatskin-Tumoren. Patienten und Methode: 30 Patienten wurden wegen extrahepatischer proximaler Gallengangskarzinome behandelt. Unser Therapieschema umfasste eine perkutane Strahlentherapie (mediane Dosis: 30 Gy) sowie einen

  18. 10 CFR 835.203 - Combining internal and external equivalent doses.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.203 Combining internal and external equivalent doses. (a) The total effective dose...

  19. Cobalt-60 Machines and Medical Linear Accelerators: Competing Technologies for External Beam Radiotherapy.

    Science.gov (United States)

    Healy, B J; van der Merwe, D; Christaki, K E; Meghzifene, A

    2017-02-01

    Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment

  20. Proton external beam in the TANDAR Accelerator; Haz externo de protones en el acelerador TANDAR

    Energy Technology Data Exchange (ETDEWEB)

    Rey, R; Schuff, J A; Perez de la Hoz, A.; Debray, M E; Hojman, D; Kreiner, A J; Kesque, J M; Saint-Martin, G; Oppezzo, O; Bernaola, O A; Molinari, B L; Duran, H A; Policastro, L; Palmieri, M; Ibanez, J; Stoliar, P; Mazal, A; Caraballo, M E; Burlon, A; Cardona, M A; Vazquez, M E; Salfity, M F; Ozafran, M J; Naab, F; Levinton, G; Davidson, M; Buhler, M [Departamento de Fisica, Comision Nacional de Energia Atomica, Av. Gral. Paz 1499, C.P. 1650 San Martin, Buenos Aires (Argentina)

    1999-12-31

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm{sup 2} approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  1. Proton external beam in the TANDAR Accelerator; Haz externo de protones en el acelerador TANDAR

    Energy Technology Data Exchange (ETDEWEB)

    Rey, R.; Schuff, J.A.; Perez de la Hoz, A.; Debray, M.E.; Hojman, D.; Kreiner, A.J.; Kesque, J.M.; Saint-Martin, G.; Oppezzo, O.; Bernaola, O.A.; Molinari, B.L.; Duran, H.A.; Policastro, L.; Palmieri, M.; Ibanez, J.; Stoliar, P.; Mazal, A.; Caraballo, M.E.; Burlon, A.; Cardona, M.A.; Vazquez, M.E.; Salfity, M.F.; Ozafran, M.J.; Naab, F.; Levinton, G.; Davidson, M.; Buhler, M. [Departamento de Fisica, Comision Nacional de Energia Atomica, Av. Gral. Paz 1499, C.P. 1650 San Martin, Buenos Aires (Argentina)

    1998-12-31

    An external proton beam has been obtained in the TANDAR accelerator with radiological and biomedical purposes. The protons have excellent physical properties for their use in radiotherapy allowing a very good accuracy in the dose spatial distribution inside the tissue so in the side direction as in depth owing to the presence of Bragg curve. The advantage of the accuracy in the dose localization with proton therapy is good documented (M. Wagner, Med. Phys. 9, 749 (1982); M. Goitein and F. Chen, Med. Phys. 10, 831 (1983); M.R. Raju, Rad. Res. 145, 391 (1996)). It was obtained external proton beams with energies between 15-25 MeV, currents between 2-10 p A and a uniform transversal sections of 40 mm{sup 2} approximately. It was realized dosimetric evaluations with CR39 and Makrofol foliation. The irradiations over biological material contained experiences In vivo with laboratory animals, cellular and bacterial crops. It was fixed the optimal conditions of position and immobilization of the Wistar rats breeding for the In vivo studies. It was chosen dilutions and sowing techniques adequate for the exposition at the cellular and bacterial crops beam. (Author)

  2. Self-Nulling Beam Combiner Using No External Phase Inverter

    Science.gov (United States)

    Bloemhof, Eric E.

    2010-01-01

    A self-nulling beam combiner is proposed that completely eliminates the phase inversion subsystem from the nulling interferometer, and instead uses the intrinsic phase shifts in the beam splitters. Simplifying the flight instrument in this way will be a valuable enhancement of mission reliability. The tighter tolerances on R = T (R being reflection and T being transmission coefficients) required by the self-nulling configuration actually impose no new constraints on the architecture, as two adaptive nullers must be situated between beam splitters to correct small errors in the coatings. The new feature is exploiting the natural phase shifts in beam combiners to achieve the 180 phase inversion necessary for nulling. The advantage over prior art is that an entire subsystem, the field-flipping optics, can be eliminated. For ultimate simplicity in the flight instrument, one might fabricate coatings to very high tolerances and dispense with the adaptive nullers altogether, with all their moving parts, along with the field flipper subsystem. A single adaptive nuller upstream of the beam combiner may be required to correct beam train errors (systematic noise), but in some circumstances phase chopping reduces these errors substantially, and there may be ways to further reduce the chop residuals. Though such coatings are beyond the current state of the art, the mechanical simplicity and robustness of a flight system without field flipper or adaptive nullers would perhaps justify considerable effort on coating fabrication.

  3. Combined techniques for network measurements at accelerator facilities

    International Nuclear Information System (INIS)

    Pschorn, I.

    1999-01-01

    Usually network measurements at GSi (Gesellschaft fur Schwerionen forschung) are carried out by employing the Leica tachymeter TC2002K etc. Due to time constraints and the fact that GSi possesses only one of these selected, high precision total-stations, it was suddenly necessary to think about employing a Laser tracker as the major instrument for a reference network measurement. The idea was to compare the different instruments and to proof if it is possible at all to carry out a precise network measurement using a laser tracker. In the end the SMX Tracker4500 combined with Leica NA3000 for network measurements at GSi, Darmstadt and at BESSY Il, Berlin (both located in Germany) was applied. A few results are shown in the following chapters. A new technology in 3D metrology came up. Some ideas of applying these new tools in the field of accelerator measurements are given. Finally aspects of calibration and checking the performance of the employed high precision instrument are pointed out in this paper. (author)

  4. Accelerant-related burns and drug abuse: Challenging combination.

    Science.gov (United States)

    Leung, Leslie T F; Papp, Anthony

    2018-05-01

    Accelerants are flammable substances that may cause explosion when added to existing fires. The relationships between drug abuse and accelerant-related burns are not well elucidated in the literature. Of these burns, a portion is related to drug manufacturing, which have been shown to be associated with increased burn complications. 1) To evaluate the demographics and clinical outcomes of accelerant-related burns in a Provincial Burn Centre. 2) To compare the clinical outcomes with a control group of non-accelerant related burns. 3) To analyze a subgroup of patients with history of drug abuse and drug manufacturing. Retrospective case control study. Patient data associated with accelerant-related burns from 2009 to 2014 were obtained from the British Columbia Burn Registry. These patients were compared with a control group of non-accelerant related burns. Clinical outcomes that were evaluated include inhalational injury, ICU length of stay, ventilator support, surgeries needed, and burn complications. Chi-square test was used to evaluate categorical data and Student's t-test was used to evaluate mean quantitative data with the p value set at 0.05. A logistic regression model was used to evaluate factors affecting burn complications. Accelerant-related burns represented 28.2% of all burn admissions (N=532) from 2009 to 2014. The accelerant group had higher percentage of patients with history of drug abuse and was associated with higher TBSA burns, ventilator support, ICU stay and pneumonia rates compared to the non-accelerant group. Within the accelerant group, there was no difference in clinical outcomes amongst people with or without history of drug abuse. Four cases were associated with methamphetamine manufacturing, all of which underwent ICU stay and ventilator support. Accelerant-related burns cause significant burden to the burn center. A significant proportion of these patients have history of drug abuse. Copyright © 2017 Elsevier Ltd and ISBI. All rights

  5. Near Infrared Photoimmunotherapy with Combined Exposure of External and Interstitial Light Sources.

    Science.gov (United States)

    Maruoka, Yasuhiro; Nagaya, Tadanobu; Sato, Kazuhide; Ogata, Fusa; Okuyama, Shuhei; Choyke, Peter L; Kobayashi, Hisataka

    2018-02-21

    Near infrared photoimmunotherapy (NIR-PIT) is a new target-cell-specific cancer treatment that induces highly selective necrotic/immunogenic cell death after systemic administration of a photoabsorber antibody conjugate and subsequent NIR light exposure. However, the depth of NIR light penetration in tissue (approximately 2 cm) with external light sources limits the therapeutic effects of NIR-PIT. Interstitial light exposure using cylindrical diffusing optical fibers can overcome this limitation. The purpose in this study was to compare three NIR light delivery methods for treating tumors with NIR-PIT using a NIR laser system at an identical light energy; external exposure alone, interstitial exposure alone, and the combination. Panitumumab conjugated with the photoabsorber IRDye-700DX (pan-IR700) was intravenously administered to mice with A431-luc xenografts which are epithelial growth factor receptor (EGFR) positive. One and 2 days later, NIR light was administered to the tumors using one of three methods. Interstitial exposure alone and in combination with external sources showed the greatest decrease in bioluminescence signal intensity. Additionally, the combination of external and interstitial NIR light exposure showed significantly greater tumor size reduction and prolonged survival after NIR-PIT compared to external exposure alone. This result suggested that the combination of external and interstitial NIR light exposure was more effective than externally applied light alone. Although external exposure is the least invasive means of delivering light, the combination of external and interstitial exposures produces superior therapeutic efficacy in tumors greater than 2 cm in depth from the tissue surface.

  6. Simulations and experiments on external electron injection for laser wakefield acceleration

    NARCIS (Netherlands)

    Dijk, van W.

    2010-01-01

    Laser wake field acceleration is a technique that can be used to accelerate electrons using electric fields that are several orders of magnitude higher than those available in conventional accelerators. With these higher fields, it is possible to drastically reduce the length of accelerator needed

  7. Combining Internal and External Evaluation: A Case for School-Based Evaluation.

    Science.gov (United States)

    Nevo, David

    1994-01-01

    School-based evaluation, the focus of this article, is conceived of as neither a synonym for internal evaluation nor an antonym for external evaluation, but as a combination that is examined through a review of recent research. A school-based evaluation in Israel illustrates combining these approaches in a complementary way. (SLD)

  8. Accelerated partial breast irradiation with external beam radiotherapy. First results of the German phase 2 trial

    Energy Technology Data Exchange (ETDEWEB)

    Ott, Oliver J.; Strnad, Vratislav; Stillkrieg, Wilhelm; Fietkau, Rainer [University Hospital Erlangen, Department of Radiation Oncology, Erlangen (Germany); Uter, Wolfgang [University Erlangen-Nuremberg, Dept. of Medical Informatics, Biometry and Epidemiology, Erlangen (Germany); Beckmann, Matthias W. [University Hospital Erlangen, Dept. of Gynecology, Erlangen (Germany)

    2017-01-15

    To evaluate the feasibility and efficacy of external beam three-dimensional (3D) conformal accelerated partial breast irradiation (APBI) for selected patients with early breast cancer. Between 2011 and 2016, 72 patients were recruited for this prospective phase 2 trial. Patients were eligible for APBI if they had histologically confirmed breast cancer or pure ductal carcinoma in situ (DCIS), a tumor diameter ≤3 cm, clear resection margins ≥2 mm, no axillary lymph node involvement, no distant metastases, tumor bed clips, and were aged ≥50 years. Patients were excluded if mammography showed a multicentric invasive growth pattern, or if they had residual diffuse microcalcifications postoperatively, an extensive intraductal component, or vessel invasion. Patients received 3D conformal external beam APBI with a total dose of 38 Gy in 10 fractions in 1-2 weeks. The trial had been registered at the German Clinical Trials Register, DRKS-ID: DRKS00004417. Median follow-up was 25.5 months (range 1-61 months). Local control was maintained in 71 of 72 patients. The 3-year local recurrence rate was 2.1% (95% confidence interval, CI: 0-6.1%). Early toxicity (grade 1 radiodermatitis) was seen in 34.7% (25/72). Late side effects ≥ grade 3 did not occur. Cosmetic results were rated as excellent/good in 96.7% (59/61). APBI with external beam radiotherapy techniques is feasible with low toxicity and, according to the results of the present and other studies, on the way to becoming a standard treatment option for a selected subgroup of patients. (orig.) [German] Untersuchung der Vertraeglichkeit und Sicherheit der externen, 3-D-konformalen akzelerierten Teilbrustbestrahlung (APBI) fuer ausgewaehlte Patientinnen mit einem fruehen Mammakarzinom. Von 2011 bis 2016 wurden 72 Patientinnen in diese prospektive Phase-2-Studie eingebracht. Einschlusskriterien waren ein histologisch gesichertes Mammakarzinom oder DCIS, ein Tumordurchmesser ≤ 3 cm, tumorfreie Resektionsraender ≥ 2

  9. The influence of external source intensity in accelerator/target/blanket system on conversion ratio and fuel cycle

    Energy Technology Data Exchange (ETDEWEB)

    Kochurov, B.P. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation)

    1995-10-01

    The analysis of neutron balance relation for a subcritical system with external source shows that a high ratio of neutron utilization (conversion ratio, breeding ratio) much exceeding similar values for nuclear reactors (both thermal or fast spectrum) is reachable in accelerator/target/blanket system with high external neutron source intensity. An accelerator/target/blanket systems with thermal power in blanket about 1850 Mwt and operating during 30 years have been investigated. Continual feed up by plutonium (fissile material) and Tc-99 (transmuted material) was assumed. Accelerator beam intensity differed 6.3 times (16 mA - Case 1, and 100 mA-Case 2). Conversion ratio (CR) was defined as the ratio of Tc-99 nuclei transmuted to the number of Pu nuclei consumed. High value of conversion ratio considerably exceeding 1 (CR=1.66) was obtained in the system with high source intensity as compared with low source system (CR=0.77). Net output of electric power of high source intensity system is about twice lower due to consumption of electric power for accelerator feed up. The loss of energy for Tc-99 transmutation is estimated as 40 Mev(el)/nuclei. Yet high conversion ratio (or breeding ratio) achievable in electronuclear installations with high intensity of external source can effectively be used to close fuel cycle (including incineration of wastes) or to develop growing nuclear power production system.

  10. Accelerating Computation of DCM for ERP in MATLAB by External Function Calls to the GPU

    Science.gov (United States)

    Wang, Wei-Jen; Hsieh, I-Fan; Chen, Chun-Chuan

    2013-01-01

    This study aims to improve the performance of Dynamic Causal Modelling for Event Related Potentials (DCM for ERP) in MATLAB by using external function calls to a graphics processing unit (GPU). DCM for ERP is an advanced method for studying neuronal effective connectivity. DCM utilizes an iterative procedure, the expectation maximization (EM) algorithm, to find the optimal parameters given a set of observations and the underlying probability model. As the EM algorithm is computationally demanding and the analysis faces possible combinatorial explosion of models to be tested, we propose a parallel computing scheme using the GPU to achieve a fast estimation of DCM for ERP. The computation of DCM for ERP is dynamically partitioned and distributed to threads for parallel processing, according to the DCM model complexity and the hardware constraints. The performance efficiency of this hardware-dependent thread arrangement strategy was evaluated using the synthetic data. The experimental data were used to validate the accuracy of the proposed computing scheme and quantify the time saving in practice. The simulation results show that the proposed scheme can accelerate the computation by a factor of 155 for the parallel part. For experimental data, the speedup factor is about 7 per model on average, depending on the model complexity and the data. This GPU-based implementation of DCM for ERP gives qualitatively the same results as the original MATLAB implementation does at the group level analysis. In conclusion, we believe that the proposed GPU-based implementation is very useful for users as a fast screen tool to select the most likely model and may provide implementation guidance for possible future clinical applications such as online diagnosis. PMID:23840507

  11. Dispersion relation and electron acceleration in the combined circular and elliptical metallic-dielectric waveguide filled by plasma

    Science.gov (United States)

    Abdoli-Arani, A.; Montazeri, M. M.

    2018-04-01

    Two special types of metallic waveguide having dielectric cladding and plasma core including the combined circular and elliptical structure are studied. Longitudinal and transverse field components in the different regions are obtained. Applying the boundary conditions, dispersion relations of the electromagnetic waves in the structures are obtained and then plotted. The acceleration of an injected external relativistic electron in the considered waveguides is studied. The obtained differential equations related to electron motion are solved by the fourth-order Runge-Kutta method. Numerical computations are made, and the results are graphically presented.

  12. Implementation of PSA models to estimate the probabilities associated with external event combination

    International Nuclear Information System (INIS)

    Burgazzi, Luciano

    2014-01-01

    This note endeavors to address some significant issues revealed by the Fukushima accident in Japan in 2011, such as the analysis of various dependency aspects arisen in the light of the external event PSA framework, as the treatment of the correlated hazards. To this aim some foundational notions to implement the PSA models related to specific aspects, like the external hazard combination, e.g., earthquake and tsunami as at the Fukushima accident, and the external hazard-caused internal events, e.g., seismic induced fire, are proposed and discussed to be incorporated within the risk assessment structure. Risk assessment of external hazards is required and utilized as an integrated part of PRA for operating and new reactor units. In the light of the Fukushima accident, of special interest are correlated events, whose modelling is proposed in the present study, in the form of some theoretical concepts, which lay the foundations for the PSA framework implementation. An applicative example is presented for illustrative purposes, since the analysis is carried out on the basis of generic numerical values assigned to an oversimplified model and results are achieved without any baseline comparison. Obviously the first step aimed at the process endorsement is the analysis of all available information in order to determine the level of applicability of the observed specific plant site events to the envisaged model and the statistical correlation analysis for event occurrence data that can be used as part of this process. Despite these drawbacks that actually do not qualify the achieved results, the present work represents an exploratory study aimed at resolving current open issues to be resolved in the PSA, like topics related to unanticipated scenarios: the combined external hazards of the earthquake and tsunami in Fukushima, external hazards causing internal events, such as seismic induced fire. These topics are to be resolved among the other ones as emerging from the

  13. Some biochemical effects of combined action of external irradiation and strontium 89

    International Nuclear Information System (INIS)

    Khadzhirusev, S.; Kiradzhiev, G.; Lalova, Kh.

    1979-01-01

    An attempt was made to assess the influence of strontium 89 on some biochemical effects, induced by external total X-irradiation of the organism in the early terms after treatment. The serum alkaline and acid phosphatase activities and the serum copper and ceruloplasmin content in rats served as indices. Inference is made that in cases, when either of the two radiation actors is alone responsible for obtaining a definite effects, their combination may integrate the biological effect, their combination may integrate the biological effects. Considerations are adduced on the dose span, within which integration of the effect may be expected. The data of this study indicate, that there is integration, when the effective dose external irradiaton effective dose internal irradiation ratio ranks from 1 : 3 to 1 : 1. No integration of effect was found in case when the effective dose of external irradiation eceeds that of internal irradiation. Data are also presented that, in conformity with the parameters studied, the minimal effective radiostrontium dose, generated in the critical organs, is approximately 3 times higher than the minimal effective dose of external irradiation. (author)

  14. Recent results on the beat wave acceleration of externally injected electrons on a plasma

    International Nuclear Information System (INIS)

    Clayton, C.E.; Marsh, K.; Dyson, A.; Everett, M.; Lal, A.; Josh, C.; Williams, R.; Katsouleas, T.

    1992-01-01

    In the Plasma Beat Wave Accelerator (PBWA) two laser beams of slightly different frequencies resonantly beat in a plasma in such a way that their frequency and wavenumber differences correspond to the plasma wave frequency and wavenumber. The amplitude-modulated electromagnetic wave envelope of the laser pulse exerts a periodic nonlinear force on the plasma electrons, causing them to bunch. The resulting space-charge wave can have a phase velocity nearly equal to the speed of light. If an electron bunch is injected with a velocity close to this it can be trapped and accelerated. The UCLA program investigating PBWA has found that tunnel or multi-photon ionized plasmas a re homogeneous enough for coherent macroscopic acceleration. The laser pulse should be short, and the peak laser intensity should be such that Iλ 2 ∼ 2 x 10 16 W/cm 2 μm 2 in order to get substantial beat wave amplitudes. tab., 3 refs

  15. Center of Mass Acceleration Feedback Control of Standing Balance by Functional Neuromuscular Stimulation against External Postural Perturbations

    Science.gov (United States)

    Nataraj, Raviraj; Audu, Musa L.; Triolo, Ronald J.

    2013-01-01

    This study investigated the use of center of mass (COM) acceleration feedback for improving performance of a functional neuromuscular stimulation (FNS) control system to restore standing function to a subject with complete, thoracic-level spinal cord injury (SCI). The approach for linearly relating changes in muscle stimulation to changes in COM acceleration was verified experimentally and subsequently produced data to create an input-output map driven by sensor feedback. The feedback gains were systematically tuned to reduce upper extremity (UE) loads applied to an instrumented support device while resisting external postural disturbances. Total body COM acceleration was accurately estimated (> 89% variance explained) using three-dimensional (3-D) outputs of two accelerometers mounted on the pelvis and torso. Compared to constant muscle stimulation employed clinically, feedback control of stimulation reduced UE loading by 33%. COM acceleration feedback is advantageous in constructing a standing neuroprosthesis since it provides the basis for a comprehensive control synergy about a global, dynamic variable and requires minimal instrumentation. Future work should include tuning and testing the feedback control system during functional reaching activity that is more indicative of activities of daily living. PMID:22987499

  16. Acceleration and holographic studies on different types of dynamization of external fixators of the bones

    Science.gov (United States)

    Podbielska, Halina; Kasprzak, Henryk T.; Voloshin, Arkady S.; Pennig, Dietmar; von Bally, Gert

    1992-08-01

    The unilateral axially dynamic fixator (Orthofix) was mounted on a sheep tibial shaft. Three fixation modes: static, dynamic controlled, and dynamic free were examined by means of double exposure holographic interferometry. Simultaneously, the acceleration was measured by an accelerometer and displayed on the monitor together with loading characteristics. The first exposure was made before the acting force was applied to the tibia plateau. The second one after the moment when the acceleration wave started to propagate through the specimen. We stated that in the case of dynamization less torsion occurs at the fracture site. So far, we have not been able to determine any correlation between results of holographic and accelerometric measurements.

  17. Comparison of treatment using teletherapy (external beam radiation) alone versus teletherapy combined with brachytherapy for advanced squamous cell carcinoma of the esophagus

    International Nuclear Information System (INIS)

    Samea, Renato; Lourenco, Laercio Gomes

    2011-01-01

    Background - Squamous cell carcinoma of the esophagus is still a difficult tumor to treat with very poor prognosis. Aim - To compare the response to teletherapy treatment (external beam radiotherapy) alone versus teletherapy combined with brachytherapy for patients with advanced squamous cell carcinoma of the esophagus. Methods - Were studied 49 patients with advanced squamous cell carcinoma of the esophagus on clinical stage III (TNM-1999). They were separated into two groups. The first, underwent radiation therapy alone with linear accelerator of particles, average dose of 6000 cGy and the second to external beam radiation therapy at a dose of 5040 cGy combined with brachytherapy with Iridium 192 at a dose of 1500 cGy. Brachytherapy started one to two weeks after the end of teletherapy, and it was divided into three weekly applications of 500 cGy. Age, gender, race, habits (smoking and drinking), body mass index (BMI), complications with treatment benefits (pain relief and food satisfaction) and survival were analyzed. Results - The quality of life (food satisfaction, and pain palliation of dysphagia) were better in the group treated with external beam radiation therapy combined with brachytherapy. Survival was higher in the brachytherapy combined with external beam radiation therapy alone. Conclusion - Although the cure rate of squamous cell cancer of the esophagus is almost nil when treated with irradiation alone, this therapy is a form of palliative treatment for most patients in whom surgical contraindication exists. (author)

  18. Comparison of treatment using teletherapy (external beam radiation) alone versus teletherapy combined with brachytherapy for advanced squamous cell carcinoma of the esophagus

    Energy Technology Data Exchange (ETDEWEB)

    Samea, Renato; Lourenco, Laercio Gomes, E-mail: renatosamea@globo.com [Department of Surgical Oncology of Dr. Arnaldo Vieira de Carvalho Hospital, Sao Paulo, SP (Brazil)

    2011-10-15

    Background - Squamous cell carcinoma of the esophagus is still a difficult tumor to treat with very poor prognosis. Aim - To compare the response to teletherapy treatment (external beam radiotherapy) alone versus teletherapy combined with brachytherapy for patients with advanced squamous cell carcinoma of the esophagus. Methods - Were studied 49 patients with advanced squamous cell carcinoma of the esophagus on clinical stage III (TNM-1999). They were separated into two groups. The first, underwent radiation therapy alone with linear accelerator of particles, average dose of 6000 cGy and the second to external beam radiation therapy at a dose of 5040 cGy combined with brachytherapy with Iridium 192 at a dose of 1500 cGy. Brachytherapy started one to two weeks after the end of teletherapy, and it was divided into three weekly applications of 500 cGy. Age, gender, race, habits (smoking and drinking), body mass index (BMI), complications with treatment benefits (pain relief and food satisfaction) and survival were analyzed. Results - The quality of life (food satisfaction, and pain palliation of dysphagia) were better in the group treated with external beam radiation therapy combined with brachytherapy. Survival was higher in the brachytherapy combined with external beam radiation therapy alone. Conclusion - Although the cure rate of squamous cell cancer of the esophagus is almost nil when treated with irradiation alone, this therapy is a form of palliative treatment for most patients in whom surgical contraindication exists. (author)

  19. Identification and analysis of external event combinations for Hanhikivi 1PRA

    Energy Technology Data Exchange (ETDEWEB)

    Helander, Juho [Fennovoima Oy, Helsinki (Finland)

    2017-03-15

    Fennovoima's nuclear power plant, Hanhikivi 1, Pyhäjoki, Finland, is currently in design phase, and its construction is scheduled to begin in 2018 and electricity production in 2024. The objective of this paper is to produce a preliminary list of safety-significant external event combinations including preliminary probability estimates, to be used in the probabilistic risk assessment of Hanhikivi 1 plant. Starting from the list of relevant single events, the relevant event combinations are identified based on seasonal variation, preconditions related to different events, and dependencies (fundamental and cascade type) between events. Using this method yields 30 relevant event combinations of two events for the Hanhikivi site. The preliminary probability of each combination is evaluated, and event combinations with extremely low probability are excluded from further analysis. Event combinations of three or more events are identified by adding possible events to the remaining combinations of two events. Finally, 10 relevant combinations of two events and three relevant combinations of three events remain. The results shall be considered preliminary and will be updated after evaluating more detailed effects of different events on plant safety.

  20. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    Science.gov (United States)

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  1. Externally Controlled Injection of Electrons by a Laser Pulse in a Laser Wakefield Electron Accelerator

    CERN Document Server

    Chen Szu Yuan; Chen Wei Ting; Chien, Ting-Yei; Lee, Chau-Hwang; Lin, Jiunn-Yuan; Wang, Jyhpyng

    2005-01-01

    Spatially and temporally localized injection of electrons is a key element for development of plasma-wave electron accelerator. Here we report the demonstration of two different schemes for electron injection in a self-modulated laser wakefield accelerator (SM-LWFA) by using a laser pulse. In the first scheme, by implementing a copropagating laser prepulse with proper timing, we are able to control the growth of Raman forward scattering and the production of accelerated electrons. We found that the stimulated Raman backward scattering of the prepulse plays the essential role of injecting hot electrons into the fast plasma wave driven by the pump pulse. In the second scheme, by using a transient density ramp we achieve self-injection of electrons in a SM-LWFA with spatial localization. The transient density ramp is produced by a prepulse propagating transversely to drill a density depression channel via ionization and expansion. The same mechanism of injection with comparable efficiency is also demonstrated wi...

  2. Tuning of External Q And Phase for The Cavities of A Superconducting Linear Accelerator

    CERN Document Server

    Katalev, V V

    2004-01-01

    The RF power required for a certain gradient of a superconducting cavity depends on the beam current and coupling between the cavity and waveguide. The coupling with the cavity may be changed by variation of Qext. Different devices can be used to adjust Qext or phase. In this paper three stub and E-H tuners are compared and their usability for the RF power distribution system for the superconducting accelerator of the European Xray laser and the TESLA linear collider is considered. The tuners were analyzed by using the scattering matrix. Advantages and limitations of the devices are presented.

  3. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    Science.gov (United States)

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P  .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P  0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  4. Wavelength beam combining of a 980-nm tapered diode laser bar in an external cavity

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Thestrup Nielsen, Birgitte

    2010-01-01

    solution for preserving the beam quality of the bar in the range of that of a single emitter and at the same time, enabling the power scaling. We report spectral beam combining applied to a 12 emitter tapered laser bar at 980 nm. The external cavity has been designed for a wavelength separation of 4.0 nm......High power diode lasers are used in a large number of applications. A limiting factor for more widespread use of broad area lasers is the poor beam quality. Gain guided tapered diode lasers are ideal candidates for industrial applications that demands watt level output power with good beam quality...

  5. Enhancement of white light OLED efficiency by combining both internal and external light extraction structures

    Science.gov (United States)

    Kao, I.-Ling; Ku, Chun-Neng; Chen, Yi-Ping; Lin, Ding-Zheng

    2012-09-01

    We proposed an internal nanostructure with a high reflective index planarization layer to solve the optical loss due to the reflective index mismatch between ITO and glass substrate. In our experiments, we found the electrical property of OLED device was significantly influenced by the internal nanostructures without planarization layer. Moreover, the internal extraction structure (IES) is not necessarily beneficial for light extraction. Therefore, we proposed a new substrate combine both internal and external extraction structure (EES) to extract trapping light. We successfully developed a high refractive index (N 1.7) planarization material with flat surface (RMS roughness < 2 nm), and improved about 70% device efficiency compared to traditional glass substrate.

  6. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].

    Science.gov (United States)

    Luo, Zhongchun; Lou, Hua; Jiang, Junwei; Song, Chunlin; Gong, Min; Wang, Yongcai

    2008-08-01

    To investigate the clinical results of treating leg open fracture with soft tissue defect by pedicle flap transfer in combination with external fixator. From May 2004 to June 2007, 12 cases of leg open fracture with soft tissue defect, 9 males and 3 females aged 18-75 years, were treated. Among them, 8 cases were caused by traffic accidents, 2 crush, 1 falling and 1 mechanical accident. According to the Gustilo Classification, there were 2 cases of type II, 5 of type IIIA and 5 of type IIIB. There were 2 cases of upper-tibia fracture, 3 of middle-tibia and 7 of middle-lower. The sizes of soft tissue defect ranged from 5 cm x 3 cm to 22 cm x 10 cm.The sizes of exposed bone ranged from 3 cm x 2 cm to 6 cm x 3 cm. The course of the disease was 1-12 hours. Fracture fixation was reached by external fixators or external fixators and limited internal fixation with Kirschner wire. The wounds with exposed tendons and bones were repaired by ipsilateral local rotation flap, sural neurocutaneous flap and saphenous nerve flap. The size of selected flap ranged from 5 cm x 4 cm to 18 cm x 12 cm. Granulation wounds were repaired by skin grafting or direct suture. All patients were followed up for 6 months to 2 years. All patients survived, among whom 2 with the wound edge infection and 1 with the distal necrosis were cured by changing the dressing, 8 with pin hole infection were treated by taking out the external fixator, 1 with nonunion received fracture healing after bone graft in comminuted fracture of lower tibia, 2 suffered delayed union in middle-lower tibia fracture. The ROM of ankle in 3 cases was mildly poor with surpass-joint fixation, with plantar extension of 0-10 degrees and plantar flexion of 10-30 degrees, while the others had plantar extension of 10-20 degrees and plantar flexion of 30-50 degrees. The method of pedicle flap transfer combined with external fixator is safe and effective for the leg open fracture with soft tissue defect.

  7. Evaluation of the Induced Activity in Air by the External Proton Beam in the Target Room of the Proton Accelerator Facility of Proton Engineering Frontier Project

    International Nuclear Information System (INIS)

    Lee, Cheol Woo; Lee, Young Ouk; Cho, Young Sik; Ahn, So Hyun

    2007-01-01

    One of the radiological concerns is the worker's exposure level and the concentration of the radionuclides in the air after shutdown, for the safety analysis on the proton accelerator facility. Although, the primary radiation source is the protons accelerated up to design value, all of the radio-nuclide is produced from the secondary neutron and photon induced reaction in air. Because, the protons don't penetrate the acceleration equipment like the DTL tank wall or BTL wall, secondary neutrons or photons are only in the air in the accelerator tunnel building because of the short range of the proton in the materials. But, for the case of the target rooms, external proton beams are occasionally used in the various experiments. When these external proton beams travel through air from the end of the beam transport line to the target, they interact directly with air and produce activation products from the proton induced reaction. The external proton beam will be used in the target rooms in the accelerator facility of the Proton Accelerator Frontier Project (PEFP). In this study, interaction characteristics of the external proton beam with air and induced activity in air from the direct interaction of the proton beam were evaluated

  8. The Results of Combined External Radiotherapy and Chemotherapy in the Management of Esophageal Cancer

    International Nuclear Information System (INIS)

    Lee, Hyun Joo; Suh, Hyun Suk; Kim, Jun Hee; Kim, Chul Soo; Kim, Sung Rok; Kim, Re Hwe

    1996-01-01

    Purpose : To evaluate the role of combination therapy of external radiotherapy and chemotherapy in the management of advanced esophageal cancer as a primary treatment compared with radiation therapy alone. Methods and Materials : A retrospective review of evaluable 55 esophageal cancer patients referred to the Department of Therapeutic Radiology, Paik Hospital for the external radiotherapy between Jul. 1983 and Dec.1994 was undertaken. Combined therapy patients (A group) were 30 and radiation alone patients (B group) were 25. Median age was 60 years old in A group(ranges : 42-81) and 65 years old in B group (ranges : 50-81). The male patients were 53. The fifty patients had squamous cell carcinomas. Radiation doses of 2520-6480c Gy were delivered over a period of 4-7 weeks. using 4MV LIVAC. Chemotherapy was administered in bolus injection before, after, or during the course of external radiotherapy. The local control rate and patterns of failure according to both treatment modalities and 1,2 year survival rates according to prognostic factors (stage, tumor length, radiation dose etc.) were analysed. Results : Median follow up period was 7 months (range : 2-73 months). Median survival was 7.5 months (20 days-29 months) in A group and 5 months(20 days-73 months) in B group. The 1,2 YSRs were 26.7%, 8.9% in A group. 12.7%, 4.3% in B group (p>0.05), respectively. The 1,2 YSRs according to stage(II/III), tumor length (5cm more or less). radiation dose(5000c Gy more or less) of A and B group were analyzed and the differences of survival rates of both treatments were not statistically significant. But among group B, patients who received 5000c Gy or more showed significant survival benefits (p<0.05). The treatment response rates of A and B group were 43.8%, 25.0%, respectively. Complete response rate of 25.0% in A and 8.3% in B were achieved. The local failure and distant metastasis were 52.4%, 23.8% in A group. 64.3%, 14.3% in B group, respectively. The combination

  9. Environmental Assessment for the Warren Station externally fired combined cycle demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    The proposed Penelec project is one of 5 projects for potential funding under the fifth solicitation under the Clean Coal Technology program. In Penelec, two existing boilers would be replaced at Warren Station, PA; the new unit would produce 73 MW(e) in a combined cycle mode (using both gas-fired and steam turbines). The project would fill the need for a full utility-size demonstration of externally fire combined cycle (EFCC) technology as the next step toward commercialization. This environmental assessment was prepared for compliance with NEPA; its purpose is to provide sufficient basis for determining whether to prepare an environmental impact statement or to issue a finding of no significant impact. It is divided into the sections: purpose and need for proposed action; alternatives; brief description of affected environment; environmental consequences, including discussion of commercial operation beyond the demonstration period.

  10. Streamwise-body-force-model for rapid simulation combining internal and external flow fields

    Directory of Open Access Journals (Sweden)

    Cui Rong

    2016-10-01

    Full Text Available A streamwise-body-force-model (SBFM is developed and applied in the overall flow simulation for the distributed propulsion system, combining internal and external flow fields. In view of axial stage effects, fan or compressor effects could be simplified as body forces along the streamline. These body forces which are functions of local parameters could be added as source terms in Navier-Stokes equations to replace solid boundary conditions of blades and hubs. The validation of SBFM with uniform inlet and distortion inlet of compressors shows that pressure performance characteristics agree well with experimental data. A three-dimensional simulation of the integration configuration, via a blended wing body aircraft with a distributed propulsion system using the SBFM, has been completed. Lift coefficient and drag coefficient agree well with wind tunnel test results. Results show that to reach the goal of rapid integrated simulation combining internal and external flow fields, the computational fluid dynamics method based on SBFM is reasonable.

  11. Effects of neutron spectrum and external neutron source on neutron multiplication parameters in accelerator-driven system

    International Nuclear Information System (INIS)

    Shahbunder, Hesham; Pyeon, Cheol Ho; Misawa, Tsuyoshi; Lim, Jae-Yong; Shiroya, Seiji

    2010-01-01

    The neutron multiplication parameters: neutron multiplication M, subcritical multiplication factor k s , external source efficiency φ*, play an important role for numerical assessment and reactor power evaluation of an accelerator-driven system (ADS). Those parameters can be evaluated by using the measured reaction rate distribution in the subcritical system. In this study, the experimental verification of this methodology is performed in various ADS cores; with high-energy (100 MeV) proton-tungsten source in hard and soft neutron spectra cores and 14 MeV D-T neutron source in soft spectrum core. The comparison between measured and calculated multiplication parameters reveals a maximum relative difference in the range of 6.6-13.7% that is attributed to the calculation nuclear libraries uncertainty and accuracy for energies higher than 20 MeV and also dependent on the reaction rate distribution position and count rates. The effects of different core neutron spectra and external neutron sources on the neutron multiplication parameters are discussed.

  12. The influence of a fentanyl and dexmedetomidine combination on external respiratory functions in acute hemorrhage model

    Directory of Open Access Journals (Sweden)

    Nikolay G. Vengerovich

    2017-01-01

    Full Text Available Background. The synthetic opioid analgesic fentanyl is widely used for prophylaxis and therapy of traumatic shock associated with massive bleeding. Its side effects – skeletal muscle rigidity and respiratory center depression – are especially pronounced with repeated administration. It is rational to apply fentanyl in diminished doses in combination with non-opioid analgesics in order to reduce respiratory disturbances risk.Aim. The aim of the work is to justify the influence of opioid analgesic fentanyl and α2 -adrenomimetic dexmedetomidine combination on external respiratory functions in acute hemorrhage model.Materials and methods. Acute loss of 35–40% of circulating blood volume was modeled in experiments on 75 white mongrel male rats. The external respiratory functions (respiratory rate, respiratory volume, breath volume per minute were estimated in animals of 5 groups: 1 – rats without analgesic help (controls; 2–3 – rats receiving a single fentanyl intramuscular injection (ED99 98,96 mcg/kg or fentanyl together with dexme detomidine (ED99 of combination 67,94 mcg/kg 15 min after acute blood loss; 4–5 – rats receiving the same drugs 15 min, 30, 45 and 60 min later.Results. In experimental acute loss of 35–40% of circulating blood volume, 15 min later a secondary acute respiratory failure developed with a drop of respiratory rate, respiratory volume and volume of breath per minute by 30%, 21 and 47% (p < 0,05. The external respiratory functions recoverеd after 4 h mainly due to the increase of respiratory volume. A single intramuscular injection of fentanyl caused respiratory depression 15 min after experimental blood loss which resulted in the decrease of breath volume per minute to 30–61% (p < 0,05 for 90 min. Four intramuscular injections of fentanyl 15 min, 30, 45 and 60 min after hemorrhage caused a severe respiratory dysfunction, accompanied by apnea periods and Biot’s respiration. Respiratory rate was reduced

  13. Accelerators

    CERN Multimedia

    CERN. Geneva

    2001-01-01

    The talk summarizes the principles of particle acceleration and addresses problems related to storage rings like LEP and LHC. Special emphasis will be given to orbit stability, long term stability of the particle motion, collective effects and synchrotron radiation.

  14. Time, dose and volume factors in interstitial brachytherapy combined with external irradiation for oral tongue carcinoma

    International Nuclear Information System (INIS)

    Yorozu, Atsunori

    1996-01-01

    This is a retrospective analysis of 136 patients with squamous cell carcinoma of stages I and II of the oral tongue who were treated with interstitial brachytherapy alone or in combination with external irradiation between 1976 and 1991. Control of the primary lesion and the occurrence of late complications were analyzed with respect to dose, time and tumor size with the Cox hazard model. The 5-year survival rates for stages I and II were 84.5% and 75.6%. The 5-year primary control rate was 91.3% for stage I and 77.3% for stage II (p 50 Gy compared with a brachytherapy dose 30 mm. Late complications should be reduced by using a spacer, improvements in dental and oral hygiene, and a sophisticated implant method. (author)

  15. Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction.

    Science.gov (United States)

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2017-01-01

    Over the past decade, image quality in low-dose computed tomography has been greatly improved by various compressive sensing- (CS-) based reconstruction methods. However, these methods have some disadvantages including high computational cost and slow convergence rate. Many different speed-up techniques for CS-based reconstruction algorithms have been developed. The purpose of this paper is to propose a fast reconstruction framework that combines a CS-based reconstruction algorithm with several speed-up techniques. First, total difference minimization (TDM) was implemented using the soft-threshold filtering (STF). Second, we combined TDM-STF with the ordered subsets transmission (OSTR) algorithm for accelerating the convergence. To further speed up the convergence of the proposed method, we applied the power factor and the fast iterative shrinkage thresholding algorithm to OSTR and TDM-STF, respectively. Results obtained from simulation and phantom studies showed that many speed-up techniques could be combined to greatly improve the convergence speed of a CS-based reconstruction algorithm. More importantly, the increased computation time (≤10%) was minor as compared to the acceleration provided by the proposed method. In this paper, we have presented a CS-based reconstruction framework that combines several acceleration techniques. Both simulation and phantom studies provide evidence that the proposed method has the potential to satisfy the requirement of fast image reconstruction in practical CT.

  16. Therapeutic Effect of External Application of Ligustrazine Combined with Holistic Nursing on Pressure Sores.

    Science.gov (United States)

    Niu, Junzhi; Han, Lin; Gong, Fen

    2016-08-15

    BACKGROUND This study aimed to explore the therapeutic effect of external application of ligustrazine combined with holistic nursing on pressure sores, as well as the underlying mechanism. MATERIAL AND METHODS From February 2014 to March 2015, a total of 32 patients with Phase II and Phase III pressure sores were enrolled and randomly assigned to an experimental group or a control group. The clinical data were comparable between the 2 groups. In addition to holistic nursing, the patients in the experimental group received 4 weeks of continuous external application of ligustrazine, whereas patients in the control group received compound clotrimazole cream. Therapeutic effect and healing time were recorded. HaCaT cells were used as an in vitro model for mechanism analysis of the effect of ligustrazine in treating pressure sores. After culturing with different concentrations of ligustrazine or the inhibitor of AKT (LY294002) for 72 h, cell viability, clone formation numbers, and levels of phosphatidyl inositol 3-kinase (PI3K), p-AKT, and p-mammalian target of rapamycin (mTOR) were determined. RESULTS Compared to the control group, the total effective rate in the experimental group was significantly higher, and the healing time was significantly reduced. Cell viability and clone formation numbers were significantly upregulated by ligustrazine in a dose-dependent manner. Both the cell viability and clone formation numbers were significantly inhibited by application of LY294002. CONCLUSIONS Our results suggest that ligustrazine combined with holistic nursing is an effective treatment of pressure sores. The protective effect may be associated with the promotion of cell growth by activation of the PI3K/AKT pathway.

  17. Core characteristics on a hybrid type fast reactor system combined with proton accelerator

    International Nuclear Information System (INIS)

    Kowata, Yasuki; Otsubo, Akira

    1997-06-01

    In our study on a hybrid fast reactor system, we have investigated it from the view point of transmutation ability of trans-uranium (TRU) nuclide making the most effective use of special features (controllability, hard neutron spectrum) of the system. It is proved that a proton beam is superior in generation of neutrons compared with an electron beam. Therefore a proton accelerator using spallation reaction with a target nucleus has an advantage to transmutation of TRU than an electron one. A fast reactor is expected to primarily have a merit that the reactor can be operated for a long term without employment of highly enriched plutonium fuel by using external neutron source such as the proton accelerator. Namely, the system has a desirable characteristic of being possible to self-sustained fissile plutonium. Consequently in the present report, core characteristics of the system were roughly studied by analyses using 2D-BURN code. The possibility of self-sustained fuel was investigated from the burnup and neutronic calculation in a cylindrical core with 300w/cc of power density without considering a target material region for the accelerator. For a reference core of which the height and the radius are both 100 cm, there is a fair prospect that a long term reactor operation is possible with subsequent refueling of natural uranium, if the medium enriched (around 10wt%) uranium or plutonium fuels are fully loaded in the initial core. More precise analyses will be planed in a later fiscal year. (author)

  18. External control of the Drosophila melanogaster egg to imago development period by specific combinations of 3D low-frequency electric and magnetic fields.

    Science.gov (United States)

    Makarov, Vladimir I; Khmelinskii, Igor

    2016-01-01

    We report that the duration of the egg-to-imago development period of the Drosophila melanogaster, and the imago longevity, are both controllable by combinations of external 3-dimensional (3D) low-frequency electric and magnetic fields (LFEMFs). Both these periods may be reduced or increased by applying an appropriate configuration of external 3D LFEMFs. We report that the longevity of D. melanogaster imagoes correlates with the duration of the egg-to-imago development period of the respective eggs. We infer that metabolic processes in both eggs and imago are either accelerated (resulting in reduced time periods) or slowed down (resulting in increased time periods). We propose that external 3D LFEMFs induce electric currents in live systems as well as mechanical vibrations on sub-cell, whole-cell and cell-group levels. These external fields induce media polarization due to ionic motion and orientation of electric dipoles that could moderate the observed effects. We found that the longevity of D. melanogaster imagoes is affected by action of 3D LFEMFs on the respective eggs in the embryonic development period (EDP). We interpret this effect as resulting from changes in the regulation mechanism of metabolic processes in D. melanogaster eggs, inherited by the resulting imagoes. We also tested separate effects of either 3D electric or 3D magnetic fields, which were significantly weaker.

  19. Clearance measurements on activated parts of accelerators by combined methods; Verfahrenskombinierte Freigabemessung aktivierter Beschleunigerteile

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, S.; Friedemann, S. [VKTA, Dresden (Germany); Enghardt, W. [Technische Univ. Dresden (Germany). OncoRay

    2016-07-01

    The process of clearance of radioactive materials according to paragraph 29 StrlSchV contents the comparison of activity to mass and surface of the material. To avoid a borderless assessment of activity of activation it is often necessary to use combined measurement methods: For clearance of collimators of a medical proton accelerator (energy range up to 200 MeV) it needs to know the nuclide composition. The energetical and geometrical calibration was fixed by experiments. The clearance based on measurements of activity distribution, gammaspectroscopy verification of nuclide composition and gamma-counting detectors. Parts of medical electron-accelerators achieved its clearance by combination of abovementioned methods and in-situ-gammaspectroscopy. Activated und contaminated lead stones achieved its clearance by measurements of fluence, laboratory evaluation of samples, in-situ-gammaspectroscopy and wipe tests.

  20. Dosimetric comparison of proton and photon three-dimensional, conformal, external beam accelerated partial breast irradiation techniques

    International Nuclear Information System (INIS)

    Kozak, Kevin R.; Katz, Angela; Adams, Judith C.; Crowley, Elizabeth M.; Nyamwanda, Jacqueline A.C.; Feng, Jennifer K.C.; Doppke, Karen P.; DeLaney, Thomas F.; Taghian, Alphonse G.

    2006-01-01

    Purpose: To compare the dosimetry of proton and photon-electron three-dimensional, conformal, external beam accelerated partial breast irradiation (3D-CPBI). Methods and Materials: Twenty-four patients with fully excised, Stage I breast cancer treated with adjuvant proton 3D-CPBI had treatment plans generated using the mixed-modality, photon-electron 3D-CPBI technique. To facilitate dosimetric comparisons, planning target volumes (PTVs; lumpectomy site plus 1.5-2.0 cm margin) and prescribed dose (32 Gy) were held constant. Plans were optimized for PTV coverage and normal tissue sparing. Results: Proton and mixed-modality plans both provided acceptable PTV coverage with 95% of the PTV receiving 90% of the prescribed dose in all cases. Both techniques also provided excellent dose homogeneity with a dose maximum exceeding 110% of the prescribed dose in only one case. Proton 3D-CPBI reduced the volume of nontarget breast tissue receiving 50% of the prescribed dose by an average of 36%. Statistically significant reductions in the volume of total ipsilateral breast receiving 100%, 75%, 50%, and 25% of the prescribed dose were also observed. The use of protons resulted in small, but statistically significant, reductions in the radiation dose delivered to 5%, 10%, and 20% of ipsilateral and contralateral lung and heart. The nontarget breast tissue dosimetric advantages of proton 3D-CPBI were not dependent on tumor location, breast size, PTV size, or the ratio of PTV to breast volume. Conclusions: Compared to photon-electron 3D-CPBI, proton 3D-CPBI significantly reduces the volume of irradiated nontarget breast tissue. Both approaches to accelerated partial breast irradiation offer exceptional lung and heart sparing

  1. Externally-fired combined cycle: An effective coal fueled technology for repowering and new generation

    Energy Technology Data Exchange (ETDEWEB)

    Stoddard, L.E.; Bary, M.R. [Black and Veatch, Kansas City, MO (United States); Gray, K.M. [Pennsylvania Electric Co., Johnstown, PA (United States); LaHaye, P.G. [Hague International, South Portland, ME (United States)

    1995-06-01

    The Externally-Fired Combined Cycle (EFCC) is an attractive emerging technology for powering high efficiency combined gas and steam turbine cycles with coal or other ash bearing fuels. In the EFCC, the heat input to a gas turbine is supplied indirectly through a ceramic air heater. The air heater, along with an atmospheric coal combustor and ancillary equipment, replaces the conventional gas turbine combustor. A steam generator located downstream from the ceramic air heater and steam turbine cycle, along with an exhaust cleanup system, completes the combined cycle. A key element of the EFCC Development Program, the 25 MMBtu/h heat-input Kennebunk Test Facility (KTF), has recently begun operation. The KTF has been operating with natural gas and will begin operating with coal in early 1995. The US Department of Energy selected an EFCC repowering of the Pennsylvania Electric Company`s Warren Station for funding under the Clean Coal Technology Program Round V. The project focuses on repowering an existing 48 MW (gross) steam turbine with an EFCC power island incorporating a 30 MW gas turbine, for a gross power output of 78 MW and a net output of 72 MW. The net plant heat rate will be decreased by approximately 30% to below 9,700 Btu/kWh. Use of a dry scrubber and fabric filter will reduce sulfur dioxide (SO{sub 2}) and particulate emissions to levels under those required by the Clean Air Act Amendments (CAAA) of 1990. Nitrogen oxides (NO{sub x}) emissions are controlled by the use of staged combustion. The demonstration project is currently in the engineering phase, with startup scheduled for 1997. This paper discusses the background of the EFCC, the KTF, the Warren Station EFCC Clean Coal Technology Demonstration Project, the commercial plant concept, and the market potential for the EFCC.

  2. Three-dimensional intrafractional internal target motions in accelerated partial breast irradiation using three-dimensional conformal external beam radiotherapy.

    Science.gov (United States)

    Hirata, Kimiko; Yoshimura, Michio; Mukumoto, Nobutaka; Nakamura, Mitsuhiro; Inoue, Minoru; Sasaki, Makoto; Fujimoto, Takahiro; Yano, Shinsuke; Nakata, Manabu; Mizowaki, Takashi; Hiraoka, Masahiro

    2017-07-01

    We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI). Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity. The peak-to-peak respiratory-induced motions ranged from 0.6 to 1.5mm in all directions. A systematic baseline drift of 1.5mm towards the posterior direction and a random baseline drift of 0.3mm in the lateral-medial and cranial-caudal directions were observed. The baseline for an outer tumour cavity drifted towards the lateral and posterior directions, and that for an upper tumour cavity drifted towards the cranial direction. Moderate correlations were observed between the posterior baseline drift and the patients' physical characteristics. The posterior margin for intrafractional uncertainties was larger than 5mm in patients with greater fat thickness due to the baseline drift. The magnitude of the intrafractional motion was not uniform according to the direction, patients' physical characteristics, or tumour cavity location due to the baseline drift. Therefore, the intrafractional systematic movement should be properly managed. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    Science.gov (United States)

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  4. Acute Effect of Different Combined Stretching Methods on Acceleration and Speed in Soccer Players

    Directory of Open Access Journals (Sweden)

    Amiri-Khorasani Mohammadtaghi

    2016-04-01

    Full Text Available The purpose of this study was to investigate the acute effect of different stretching methods, during a warm-up, on the acceleration and speed of soccer players. The acceleration performance of 20 collegiate soccer players (body height: 177.25 ± 5.31 cm; body mass: 65.10 ± 5.62 kg; age: 16.85 ± 0.87 years; BMI: 20.70 ± 5.54; experience: 8.46 ± 1.49 years was evaluated after different warm-up procedures, using 10 and 20 m tests. Subjects performed five types of a warm-up: static, dynamic, combined static + dynamic, combined dynamic + static, and no-stretching. Subjects were divided into five groups. Each group performed five different warm-up protocols in five non-consecutive days. The warm-up protocol used for each group was randomly assigned. The protocols consisted of 4 min jogging, a 1 min stretching program (except for the no-stretching protocol, and 2 min rest periods, followed by the 10 and 20 m sprint test, on the same day. The current findings showed significant differences in the 10 and 20 m tests after dynamic stretching compared with static, combined, and no-stretching protocols. There were also significant differences between the combined stretching compared with static and no-stretching protocols. We concluded that soccer players performed better with respect to acceleration and speed, after dynamic and combined stretching, as they were able to produce more force for a faster execution.

  5. Assessement of the effect of Pyrimetin in combined injury with external irradiation and oral cerium-144 incorporation

    International Nuclear Information System (INIS)

    Kiradzhiev, G.; Khadzhidekova, E.

    1985-01-01

    The effect of the preparation Pyrimetin on rats, subjected to external irradiation combined with oral cerium 144 incorporation was studied. LD 50/30 of cerium-144 was used as biological criterion. It was shown that by this criterion Pyrimetin essentially abolished the potentiated by external radiation effect of cerium. Probably, the preparation leads to normalization of the gastro-intestinal motor function and the dose loading of the colon

  6. Initial dosimetric experience using simple three-dimensional conformal external-beam accelerated partial-breast irradiation

    International Nuclear Information System (INIS)

    Taghian, Alphonse G.; Kozak, Kevin R.; Doppke, Karen P.; Katz, Angela; Smith, Barbara L.; Gadd, Michele; Specht, Michelle; Hughes, Kevin; Braaten, Kristina; Kachnic, Lisa A.; Recht, Abram; Powell, Simon N.

    2006-01-01

    Purpose: Several accelerated partial-breast irradiation (APBI) techniques are being investigated in patients with early-stage breast cancer. We present our initial experience using three-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: Sixty-one patients with tumors of 2 cm or less and negative axillary nodes were treated with 3D-CRT accelerated partial-breast irradiation (APBI) between August 2003 and March 2005. The prescribed radiation dose was 32 Gy in 4-Gy fractions given twice daily. Efforts were made to minimize the number of beams required to achieve adequate planning target volume (PTV) coverage. Results: A combination of photons and electrons was used in 85% of patients. A three-field technique that consisted of opposed, conformal tangential photons and enface electrons was employed in 43 patients (70%). Nine patients (15%) were treated with a four-field arrangement, which consisted of three photon fields and enface electrons. Mean PTV volumes that received 100%, 95%, and 90% of the prescribed dose were 93% ± 7%, 97% ± 4%, and 98% ± 2%, respectively. Dose inhomogeneity exceeded 10% in only 7 patients (11%). Mean doses to the ipsilateral lung and heart were 1.8 Gy and 0.8 Gy, respectively. Conclusions: Simple 3D-CRT techniques of APBI can achieve appropriate PTV coverage while offering significant normal-tissue sparing. Therefore, this noninvasive approach may increase the availability of APBI to patients with early-stage breast cancer

  7. Effect of an external magnetic field on particle acceleration by a rotating black hole surrounded with quintessential energy

    Science.gov (United States)

    Shaymatov, Sanjar; Ahmedov, Bobomurat; Stuchlík, Zdeněk; Abdujabbarov, Ahmadjon

    We investigate particle motion and collisions in the vicinity of rotating black holes immersed in combined cosmological quintessential scalar field and external magnetic field. The quintessential dark-energy field governing the spacetime structure is characterized by the quintessential state parameter ωq ∈ (‑1; ‑1/3) characterizing its equation of state, and the quintessential field-intensity parameter c determining the static radius where the black hole attraction is just balanced by the quintessential repulsion. The magnetic field is assumed to be test field that is uniform close to the static radius, where the spacetime is nearly flat, being characterized by strength B there. Deformations of the test magnetic field in vicinity of the black hole, caused by the Ricci non-flat spacetime structure are determined. General expression of the center-of-mass energy of the colliding charged or uncharged particles near the black hole is given and discussed in several special cases. In the case of nonrotating black holes, we discuss collisions of two particles freely falling from vicinity of the static radius, or one such a particle colliding with charged particle revolving at the innermost stable circular orbit. In the case of rotating black holes, we discuss briefly particles falling in the equatorial plane and colliding in close vicinity of the black hole horizon, concentrating attention to the interplay of the effects of the quintessential field and the external magnetic field. We demonstrate that the ultra-high center-of-mass energy can be obtained for black holes placed in an external magnetic field for an infinitesimally small quintessential field-intensity parameter c; the center-of-mass energy decreases if the quintessential field-intensity parameter c increases.

  8. A method to combine three dimensional dose distributions for external beam and brachytherapy radiation treatments for gynecological neoplasms

    International Nuclear Information System (INIS)

    Narayana, V.; Sahijdak, W.M.; Orton, C.G.

    1997-01-01

    Purpose: Radiation treatment of gynecological neoplasms, such as cervical carcinoma, usually combines external radiation therapy with one or more intracavitary brachytherapy applications. Although the dose from external beam radiation therapy and brachytherapy can be calculated and displayed in 3D individually, the dose distributions are not combined. At most, combined point doses are calculated for select points using various time-dose models. In this study, we present a methodology to combine external beam and brachytherapy treatments for gynecological neoplasms. Material and Methods: Three dimensional bio-effect treatment planning to obtain complication probability has been outlined. CT scans of the patient's pelvis with the gynecological applicator in place are used to outline normal tissue and tumor volumes. 3D external beam and brachytherapy treatment plans are developed separately and an external beam dose matrix and a brachytherapy dose matrix was calculated. The dose in each voxel was assumed to be homogeneous. The physical dose in each voxel of the dose matrix was then converted into extrapolated response dose (ERD) based on the linear quadratic model that accounts for the dose per fraction, number of fractions, dose rate, and complete or incomplete repair of sublethal damage (time between fractions). The net biological dose delivered was obtained by summing the ERD grids from external beam and brachytherapy since there was complete repair of sublethal damage between external beam and brachytherapy treatments. The normal tissue complication probability and tumor control probability were obtained using the biological dose matrix based on the critical element model. Results: The outlined method of combining external beam and brachytherapy treatments was implemented on gynecological treatments using an applicator for brachytherapy treatments. Conclusion: Implementation of the biological dose calculation that combine different modalities is extremely useful

  9. Combined system of accelerator molten-salt breeder (AMSB) apd molten-salt converter reactor (MSCR)

    International Nuclear Information System (INIS)

    Furukawa, K.; Kato, Y.; Ohmichi, T.; Ohno, H.

    1983-01-01

    A design and research program is discUssed of the development of accelerator molten-salt breeder (AMSB) consisting of a proton accelerator and a molten fluoride target. The target simultaneously serves as a blanket for fissionable material prodUction. An addition of some amoUnt of fissile nuclides to a melt expands the AMSB potentialities as the fissionable material production increases and the energy generation also grows up to the level of self-provision. Besides the blanket salts may be used as nuclear fuel for molten-salt converter reactor (MSCR). The combined AM SB+MSCR system has better parameters as compared to other breeder reactors, molten-salt breeder reactors (MSBR) included

  10. Accelerated testing of solid oxide fuel cell stacks for micro combined heat and power application

    DEFF Research Database (Denmark)

    Hagen, Anke; Høgh, Jens Valdemar Thorvald; Barfod, Rasmus

    2015-01-01

    State-of-the-art (SoA) solid oxide fuel cell (SOFC) stacks are tested using profiles relevant for use in micro combined heat and power (CHP) units. Such applications are characterised by dynamic load profiles. In order to shorten the needed testing time and to investigate potential acceleration...... of degradation, the profiles are executed faster than required for real applications. Operation with fast load cycling, both using hydrogen and methane/steam as fuels, does not accelerate degradation compared to constant operation, which demonstrates the maturity of SoA stacks and enables transferring knowledge...... effect for long life-times than regular short time changes of operation. In order to address lifetime testing it is suggested to build a testing program consisting of defined modules that represent different application profiles, such as one module at constant conditions, followed by modules at one set...

  11. Hypofractionated Proton Boost Combined with External Beam Radiotherapy for Treatment of Localized Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Silvia Johansson

    2012-01-01

    Full Text Available Proton boost of 20 Gy in daily 5 Gy fractions followed by external beam radiotherapy (EBRT of 50 Gy in daily 2 Gy fractions were given to 278 patients with prostate cancer with T1b to T4N0M0 disease. Fifty-three percent of the patients received neoadjuvant androgen deprivation therapy (N-ADT. The medium followup was 57 months. The 5-year PSA progression-free survival was 100%, 95%, and 74% for low-, intermediate-, and high-risk patients, respectively. The toxicity evaluation was supported by a patient-reported questionnaire before every consultant visit. Cumulative probability and actuarial prevalence of genitourinary (GU and gastrointestinal (GI toxicities are presented according to the RTOG classification. N-ADT did not influence curability. Mild pretreatment GU-symptoms were found to be a strong predictive factor for GU-toxicity attributable to treatment. The actuarial prevalence declined over 3 to 5 years for both GU and GI toxicities, indicating slow resolution of epithelial damage to the genitourinary and gastrointestinal tract. Bladder toxicities rather than gastrointestinal toxicities seem to be dose limiting. More than 5-year followup is necessary to reveal any sign of true progressive late side effects of the given treatment. Hypofractionated proton-boost combined with EBRT is associated with excellent curability of localized PC and acceptable frequencies of treatment toxicity.

  12. Daylight Design of Office Buildings: Optimisation of External Solar Shadings by Using Combined Simulation Methods

    Directory of Open Access Journals (Sweden)

    Javier González

    2015-05-01

    Full Text Available Integrating daylight and energy performance with optimization into the design process has always been a challenge for designers. Most of the building environmental performance simulation tools require a considerable amount of time and iterations for achieving accurate results. Moreover the combination of daylight and energy performances has always been an issue, as different software packages are needed to perform detailed calculations. A simplified method to overcome both issues using recent advances in software integration is explored here. As a case study; the optimization of external shadings in a typical office space in Australia is presented. Results are compared against common solutions adopted as industry standard practices. Visual comfort and energy efficiency are analysed in an integrated approach. The DIVA (Design, Iterate, Validate and Adapt plug-in for Rhinoceros/Grasshopper software is used as the main tool, given its ability to effectively calculate daylight metrics (using the Radiance/Daysim engine and energy consumption (using the EnergyPlus engine. The optimization process is carried out parametrically controlling the shadings’ geometries. Genetic Algorithms (GA embedded in the evolutionary solver Galapagos are adopted in order to achieve close to optimum results by controlling iteration parameters. The optimized result, in comparison with conventional design techniques, reveals significant enhancement of comfort levels and energy efficiency. Benefits and drawbacks of the proposed strategy are then discussed.

  13. Hypofractionated Proton Boost Combined with External Beam Radiotherapy for Treatment of Localized Prostate Cancer

    Science.gov (United States)

    Johansson, Silvia; Åström, Lennart; Sandin, Fredrik; Isacsson, Ulf; Montelius, Anders; Turesson, Ingela

    2012-01-01

    Proton boost of 20 Gy in daily 5 Gy fractions followed by external beam radiotherapy (EBRT) of 50 Gy in daily 2 Gy fractions were given to 278 patients with prostate cancer with T1b to T4N0M0 disease. Fifty-three percent of the patients received neoadjuvant androgen deprivation therapy (N-ADT). The medium followup was 57 months. The 5-year PSA progression-free survival was 100%, 95%, and 74% for low-, intermediate-, and high-risk patients, respectively. The toxicity evaluation was supported by a patient-reported questionnaire before every consultant visit. Cumulative probability and actuarial prevalence of genitourinary (GU) and gastrointestinal (GI) toxicities are presented according to the RTOG classification. N-ADT did not influence curability. Mild pretreatment GU-symptoms were found to be a strong predictive factor for GU-toxicity attributable to treatment. The actuarial prevalence declined over 3 to 5 years for both GU and GI toxicities, indicating slow resolution of epithelial damage to the genitourinary and gastrointestinal tract. Bladder toxicities rather than gastrointestinal toxicities seem to be dose limiting. More than 5-year followup is necessary to reveal any sign of true progressive late side effects of the given treatment. Hypofractionated proton-boost combined with EBRT is associated with excellent curability of localized PC and acceptable frequencies of treatment toxicity. PMID:22848840

  14. Combined fixation, intern and external, in proximal complex fractures of the tibia

    International Nuclear Information System (INIS)

    Quintero Laverde, Jaime; Lozano Ortiz, Victor Hugo; Rojas Duque, Guillermo

    2002-01-01

    Between August of 1997 and December of 2001, they were treated in the orthopedics department and traumatology of the Hospital Clinica San Rafael, 16 patients with proximal complex fractures of the tibia, using internal fixation with plate in the lateral column and an unilateral external fixer, for the medial column. It carries out a clinical and radiological pursuit with average of 27 months (minimum 4.5, maximum 40 months). In 15 patients (93,7%) it was obtained a primary consolidation and 1 case (6,2%) it presented retard in the consolidation being necessary the placement of bony implants. in 2 cases (12,5%) there was superficial infection, one in the itinerary of the nails and another in area of superficial necrosis in soft fabrics in a closed fracture. single 1 case (6,2) it presented deep infection, which, it improve with bony curettage and antibiotics. In the final radiographic evaluation, 2 cases (12,5%) they presented depression of the lateral plate; according to the functional scale of Rasmussen excellent results were obtained (27 to 30 points) in 11 cases (68,7%) and good (20 to 26 points) in 5 cases (31,2%). The radiographic results and functional global they suggest that the combination of a technique less invasive in this area criticizes, it represents a good alternative for the treatment of the proximal complex fractures of the tibia

  15. [TREATMENT OF PRONATION EXTERNAL ROTATION ANKLE FRACTURE COMBINED WITH SEPARATION OF DISTAL TIBIOFIBULAR SYNDESMOSIS].

    Science.gov (United States)

    Wu, Benwen; Ding, Zhenqi; Huang, Guofeng; Liu, Guojun; Cai, Zhemin; Ding, Luobin; Li, Xiang

    2016-09-08

    To evaluate the difference between using and not using syndesmotic screw to treat pronation external rotation (PER) ankle fracture combined with separation of distal tibiofibular syndesmosis. Between April 2011 and October 2014, 46 cases of PER ankle fracture combined with separation of distal tibiofibular syndesmosis were treated, and syndesmotic screw was used in 24 cases (fixation group) and syndesmotic screw was not used in 22 cases (non-fixation group). There was no significant difference in gender, age, weight, cause of injury, side, injury to operation time, and fracture type between 2 groups ( P >0.05). The time for full weight-bearing, fracture healing time, and complications were recorded after operation. Anteroposterior and lateral X-ray films were taken to measure the tibiofibular overlap (TBOL) and tibiofibular clear space (TBCS). Baird-Jackson score was used to evaluate functional recovery of the ankle. All incision healed by first intention without complications. The cases were followed up 13-18 months (mean, 15.2 months) in 2 groups. The time for full weight-bearing was 8-12 weeks (median, 11 weeks) in fixation group, which was significantly later than that in non-fixation group (range, 6-10 weeks; median, 8 weeks) ( Z =-5.049, P =0.000). X-ray examination showed reduction of separation of distal tibiofibular syndesmosis. All fractures healed. The fracture healing time was (13.83±1.37) weeks in fixation group, and was (13.91±1.31) weeks in non-fixation group, showing no significant difference ( t =-0.191, P =0.945). No separation of distal tibiofibular syndesmosis, delayed union, nonunion, loosening, or breakage of fixation devices was observed in 2 groups. There was no significant difference in TBOL, TBCS, Baird-Jackson score and the excellent and good rate between 2 groups ( P >0.05). If the medial, lateral, and posterior structures of the ankle could be repaired according to injury, no significant influence on functional outcome of ankle or

  16. The new external ion beam analysis setup at the Demokritos Tandem accelerator and first applications in cultural heritage

    International Nuclear Information System (INIS)

    Sokaras, Dimosthenis; Bistekos, Euthimios; Georgiou, Lambros; Salomon, Joseph; Bogovac, Mladen; Aloupi-Siotis, Eleni; Paschalis, Vasilis; Aslani, Ioanna; Karabagia, Sofia; Lagoyannis, Anastasios; Harissopulos, Sotirios; Kantarelou, Vasiliki; Karydas, Andreas-Germanos

    2011-01-01

    At the 5.5 MV Tandem VdG accelerator of the Institute of Nuclear Physics of N.C.S.R. 'Demokritos', Athens, Greece, an external ion-beam set-up has been recently developed and installed. The aim of this development was to integrate the analytical capabilities of the PIXE, RBS and PIGE ion beam techniques in one experimental set-up, so that to attain a complete elemental and near surface structural characterization of samples in an almost non-destructive way and without any limitation concerning their size or conductive state. A careful 3D mechanical drawing optimized the set-up experimental parameters achieving probe dimensions at the millimeter range (1 mm 2 ) and fulfilling the special requirements imposed for optimum performance of the aforementioned techniques, including the possibility to use heavier, than protons, ion beams. For the digital pulse processing of the X-ray, γ-ray and charged particle detector signals, novel hardware and software tools were developed based on a custom FPGA configuration. The first applications were focused in the quality control of materials that have been intentionally contaminated with a particular tracer-element ('tagged' materials). The tagged materials which were developed and tested are technologically authentic replicas of ancient attic ceramics with black glazed decoration. Analytical diagnostic studies were carried out for a few representative paintings of contemporary Greek painters in order to identify and document materials/pigments and techniques and eventually to prevent trade of fakes. Finally, ancient glass beads were also examined with respect to the sodium concentration and its in-depth homogeneity.

  17. Combined influences of genes, prenatal environment, cortisol, and parenting on the development of children’s internalizing vs. externalizing problems

    Science.gov (United States)

    Marceau, Kristine; Laurent, Heidemarie K.; Neiderhiser, Jenae M.; Reiss, David; Shaw, Daniel S.; Natsuaki, Misaki; Fisher, Philip A.; Leve, Leslie D.

    2014-01-01

    Research suggests that genetic, prenatal, endocrine, and parenting influences across development individually contribute to internalizing and externalizing problems in children. The present study tests the combined contributions of genetic risk for psychopathology, prenatal environments (maternal drug use and internalizing symptoms), child cortisol at age 4.5 years, and overreactive parenting influences across childhood on 6-year-old children’s internalizing and externalizing problems. We used data from an adoption design that included 361 domestically adopted children and their biological and adopted parents prospectively followed from birth. Only parenting influences contributed (independently) to externalizing problems. However, genetic influences were indirectly associated with internalizing problems (through increased prenatal risk and subsequent morning cortisol), and parenting factors were both directly and indirectly associated with internalizing problems (through morning cortisol). Results suggest that prenatal maternal drug use/symptoms and children’s morning cortisol levels are mechanisms of genetic and environmental influences on internalizing problems, but not externalizing problems, in childhood. PMID:25355319

  18. Combined Influences of Genes, Prenatal Environment, Cortisol, and Parenting on the Development of Children's Internalizing Versus Externalizing Problems.

    Science.gov (United States)

    Marceau, Kristine; Laurent, Heidemarie K; Neiderhiser, Jenae M; Reiss, David; Shaw, Daniel S; Natsuaki, Misaki N; Fisher, Philip A; Leve, Leslie D

    2015-05-01

    Research suggests that genetic, prenatal, endocrine, and parenting influences across development individually contribute to internalizing and externalizing problems in children. The present study tests the combined contributions of genetic risk for psychopathology, prenatal environments (maternal drug use and internalizing symptoms), child cortisol at age 4.5 years, and overreactive parenting influences across childhood on 6-year-old children's internalizing and externalizing problems. We used data from an adoption design that included 361 domestically adopted children and their biological and adopted parents prospectively followed from birth. Only parenting influences contributed (independently) to externalizing problems. However, genetic influences were indirectly associated with internalizing problems (through increased prenatal risk and subsequent morning cortisol), and parenting factors were both directly and indirectly associated with internalizing problems (through morning cortisol). Results suggest that prenatal maternal drug use/symptoms and children's morning cortisol levels are mechanisms of genetic and environmental influences on internalizing problems, but not externalizing problems, in childhood.

  19. Combined Mini-Cylex & Disk Acceleration Tests in Type K Copper.

    Energy Technology Data Exchange (ETDEWEB)

    Maines, Warren Russell [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kittell, David E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hobbs, Michael L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    We combined the miniature cylinder expansion test (Mini-Cylex), with the Disk Acceleration Test (DAX) using Type K copper, Picatinny Liquid Explosive, and photonic Doppler velocimetry. We estimated the CJ state using plate reverberation methods at the test cap. We extracted velocities at 2, 7, and 10 volume expansions to fit Jones-Wilkins-Lee Equation of State at the tube wall. And we estimated Gurney velocity both at the test cap and tube wall. Our experiments and simulations are within expected uncertainty. The test and the analysis effectively reduce costs while keeping similar fidelity compared with more expensive tests.

  20. Thermodynamic Analyses of Biomass Gasification Integrated Externally Fired, Post-Firing and Dual-Fuel Combined Cycles

    Directory of Open Access Journals (Sweden)

    Saeed Soltani

    2015-01-01

    Full Text Available In the present work, the results are reported of the energy and exergy analyses of three biomass-related processes for electricity generation: the biomass gasification integrated externally fired combined cycle, the biomass gasification integrated dual-fuel combined cycle, and the biomass gasification integrated post-firing combined cycle. The energy efficiency for the biomass gasification integrated post-firing combined cycle is 3% to 6% points higher than for the other cycles. Although the efficiency of the externally fired biomass combined cycle is the lowest, it has an advantage in that it only uses biomass. The energy and exergy efficiencies are maximized for the three configurations at particular values of compressor pressure ratios, and increase with gas turbine inlet temperature. As pressure ratio increases, the mass of air per mass of steam decreases for the biomass gasification integrated post-firing combined cycle, but the pressure ratio has little influence on the ratio of mass of air per mass of steam for the other cycles. The gas turbine exergy efficiency is the highest for the three configurations. The combustion chamber for the dual-fuel cycle exhibits the highest exergy efficiency and that for the post-firing cycle the lowest. Another benefit of the biomass gasification integrated externally fired combined cycle is that it exhibits the highest air preheater and heat recovery steam generator exergy efficiencies.

  1. Locally advanced prostatic cancer: experience with combined pelvic external beam irradiation and interstitial thermobrachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, Steven L; Kapp, Daniel S; Goffinet, Don R; Prionas, Stavros; Cox, Richard S; Bagshaw, Malcolm A

    1995-07-01

    Purpose: Recurrence of prostatic carcinoma within the prostate gland remains a significant problem for patients who present with locally advanced disease. In an attempt to improve the local control of such tumors, an iridium-192 transperineal, template-guided prostatic implant was combined wit radiofrequency-induced hyperthermia after external beam irradiation of the pelvic lymph nodes and prostate gland. This study evaluates the influence of pre-treatment patient characteristics and treatment parameters upon outcome. Materials and Methods: Between July 1987 and April 1992 33 patients with adenocarcinoma of the prostate were selected for treatment: 28 of these patients had extensive local disease on clinical examination (AJCC-4 stages T2b or c: 9 patients; T3: 19 patients); two patients with T2a tumors had Gleason grade 5 + 4 disease or disproportionately high prostate specific antigen (PSA) values and a mass encroaching upon the bladder on computerized tomographic scan. Three patients with more clinically limited T2a or T2b involvement elected implantation in lieu of an external beam irradiation boost. The mean pre-treatment serum PSA value was 25.6 ng/ml (Hybritech scale), with values of above 19 ng/ml for 17 of the patients. Treatment consisted of 50 Gy of external beam irradiation to the prostate and pelvic lymph nodes followed by a transperineal needle implant of the prostate gland. Thirty-two patients had no evidence of pelvic nodal involvement during exploration at laparotomy performed after external irradiation, and 25 of these had lymph node samplings that were histologically negative for metastasis. Perineal template oriented needles were placed by inspection and palpation at laparotomy; 2 were performed closed under ultrasound guidance. Needles were afterloaded with {sup 192}Ir to provide a dose of 30 Gy to the periphery of the prostate gland. Interstitial radiofrequency-induced hyperthermia treatments were given in conjunction with the implant, one just

  2. Nonlinear oscillations of the FitzHugh-Nagumo equations under combined external and two-frequency parametric excitations

    International Nuclear Information System (INIS)

    Tatchim Bemmo, D.; Siewe Siewe, M.; Tchawoua, C.

    2011-01-01

    The continuous FitzHugh-Nagumo (FHN for short) model is transformed into modified van der Pol oscillator with asymmetry under external and two-frequency parametric excitations. At the first, the dependence of the solutions on a combined external and two-frequency parametric stimulus forcing is investigated. By using the multiple scale method, ranges of applied current and/or parametric forcing in which nonlinear oscillations are observed are described. Second, when the multiple scale method cannot be used, we numerically prove that in the modified van der Pol oscillator with asymmetry under external and two-frequency parametric excitations, chaos and periodic solution depending on the combination between different frequencies of the model should appear. We also show that the amplitude of the oscillations can be reduced or increased. To do this, we perform the study of the FHN model by choosing a range of parameters exhibiting Hopf bifurcation and two qualitative different regimes in phase portrait. - Highlights: → We model both external and two-frequency parametric excitations in FHN equations. → We examine effects of harmonic forcing on coupled nonlinear oscillator. → Jump and hysteresis phenomena are observed in the dynamical response. → By increasing the constant stimulus we obtain limit cycle. → Some combinations of frequencies produce limit cycle and chaos for other.

  3. Geometric Scaling in New Combined Hadron-Electron Ring Accelerator Data

    International Nuclear Information System (INIS)

    Zhou Xiao-Jiao; Qi Lian; Kang Lin; Xiang Wen-Chang; Zhou Dai-Cui

    2014-01-01

    We study the geometric scaling in the new combined data of the hadron-electron ring accelerator by using the Golec-Biernat—Wüsthoff model. It is found that the description of the data is improved once the high accurate data are used to determine the model parameters. The value of x 0 extracted from the fit is larger than the one from the previous study, which indicates a larger saturation scale in the new combined data. This makes more data located in the saturation region, and our approach is more reliable. This study lets the saturation model confront such high precision new combined data, and tests geometric scaling with those data. We demonstrate that the data lie on the same curve, which shows the geometric scaling in the new combined data. This outcome seems to support that the gluon saturation would be a relevant mechanism to dominate the parton evolution process in deep inelastic scattering, due to the fact that the geometric scaling results from the gluon saturation mechanism

  4. [Synergetic killing effects of external magnetic fields combined with porphyrin-dextran magnetic nanoparticles on the human bladder cancer cells].

    Science.gov (United States)

    Luo, Dao-sheng; Mi, Qi-wu; Meng, Xiang-jun; Gao, Yong; Dai, Yu-ping; Deng, Chun-hua

    2012-08-18

    To study the synergetic killing effects of external magnetic fields combined with the photodynamic action of porphyrin-dextran iron oxide magnetic nanoparticles (PDMN) on human bladder cancer cells in vitro. The PDMN were produced by using the chemical co-precipitation and redox process and the physicochemical properties were characterized. Methyl thiazolyl tetrazolium (MTT) and flow cytometry were used to determine the effects of photodynamic therapy of PDMN combined with external pulsed electromagnetic fields (5 mT) on killing human bladder cancer BIU-87 cells respectively. The diameters of PDMN were 10-15 nm and the saturation magnetization was 0.20 emu/g. Effective diameter of PDMN was 94.8 nm. PDMN could remarkably inhibit the proliferation and induce the obvious apoptosis of BIU-87 cells, and the rates of growth inhibition and apoptosis were (17.61±2.73)% and (24.53±5.74)% respectively. Moreover, external pulsed electromagnetic fields (5 mT) could also suppress the proliferation and induce apoptosis of BIU-87 cells. Furthermore, the photodynamic action of PDMN combined with external magnetic fields significantly inhibited the proliferation and promote apoptosis of BIU-87 cells, and the rates of growth inhibition and apoptosis was (28.11±4.25)% and (24.53±5.74)%, respectively, which were significantly higher than those of other groups (Peffectively inhibit proliferation and induce apoptosis of BIU-87 cells. Moreover, these effects on BIU-87 cells could be strengthened by the combination with external magnetic fields.

  5. Combined effect of external irradiation and radiostrontium administration (extrapolation of experimental data)

    International Nuclear Information System (INIS)

    Kiradzhiev, G.

    1987-01-01

    Assessment was made of the activities of strontium-89 and strontium-90, which may aggravate the effect of external irradiation, causing changes in peripheral blood leucocytes. Extrapolation of the results was carried out on the basis of the so called radiosensitivity coefficients (laboratory rat/man). Inference is drawn that summing of the effects of the radiation factors may be expected in cases of external irradiation with 100 Gy and oral administration of 150-200 MBq strontium-89 or 60-90 MBq strontium-90 and through the air passages of 110-150 MBq strontium-89 or 40-60 MBq strontium-90

  6. A procedure for combining rotating-coil measurements of large-aperture accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Köster, Oliver, E-mail: oliver.koester@cern.ch; Fiscarelli, Lucio, E-mail: lucio.fiscarelli@cern.ch; Russenschuck, Stephan, E-mail: stephan.russenschuck@cern.ch

    2016-05-11

    The rotating search coil is a precise and widely used tool for measuring the magnetic field harmonics of accelerator magnets. This paper deals with combining several such multipole measurements, in order to cover magnet apertures largely exceeding the diameter of the available search coil. The method relies on the scaling laws for multipole coefficients and on the method of analytic continuation along zero-homotopic paths. By acquiring several measurements of the integrated magnetic flux density at different transverse positions within the bore of the accelerator magnet, the uncertainty on the field harmonics can be reduced at the expense of tight tolerances on the positioning. These positioning tolerances can be kept under control by mounting the rotating coil and its motor-drive unit on precision alignment stages. Therefore, the proposed technique is able to yield even more precise results for the higher-order field components than a dedicated rotating search coil of larger diameter. Moreover, the versatility of the measurement bench is enhanced by avoiding the construction of rotating search coils of different measurement radii.

  7. Accelerated thermal and radiation-oxidation combined degradation of electric cable insulation materials

    International Nuclear Information System (INIS)

    Yagi, Toshiaki; Seguchi, Tadao; Yoshida, Kenzo

    1986-03-01

    For the development of accelerated testing methodology to estimate the life time of electric cable, which is installed in radiation field such as a nuclear reactor containment vessel, radiation and thermal combined degradation of cable insulation and jacketing materials was studied. The materials were two types of formulated polyethylene, ethylene-propylene rubber, Hypalon, and Neoprene. With Co-60 γ-rays the materials were irradiated up to 0.5 MGy under vacuum and in oxygen under pressure, then exposed to thermal aging at elevated temperature in oxygen. The degradation was investigated by the tensile test, gelfraction, and swelling measurements. The thermal degradation rate for each sample increases with increase of oxygen concentration, i.e. oxygen pressure, during the aging, and tends to saturate above 0.2 MPa of oxygen pressure. Then, the effects of irradiation and the temperature on the thermal degradation rate were investigated at the oxygen pressure of 0.2 MPa in the temperature range from 110 deg C to 150 deg C. For all of samples irradiated in oxygen, the following thermal degradation rate was accelerated by several times comparing with unirradiated samples, while the rate of thermal degradation for the sample except Neoprene irradiated under vacuum was nearly equal to that of unirradiated one. By the analysis of thermal degradation rate against temperature using Arrhenius equation, it was found that the activation energy tends to decrease for the samples irradiated in oxidation condition. (author)

  8. Mercury risk assessment combining internal and external exposure methods for a population living near a municipal solid waste incinerator.

    Science.gov (United States)

    Deng, Chunyan; Xie, Han; Ye, Xuejie; Zhang, Haoran; Liu, Maodian; Tong, Yindong; Ou, Langbo; Yuan, Wen; Zhang, Wei; Wang, Xuejun

    2016-12-01

    Risk assessments for human health have been conducted for municipal solid waste incinerators (MSWIs) in many western countries, whereas only a few risk assessments have been performed for MSWIs in developing countries such as China where the use of waste incineration is increasing rapidly. To assess the mercury exposure risks of a population living near the largest MSWI in South China, we combined internal exposure and external exposure assessment with an individual-specific questionnaire. The mercury concentrations in air, soil, and locally collected food around the MSWI were assessed. The total mercury (T-Hg) and methylmercury (MeHg) of 447 blood samples from a control group, residential exposure group, and MSWI workers were measured. The internal and external exposures of the subject population were analyzed. Significant difference in MeHg concentrations was observed between the control group and the exposed group, between the control group and the MSWI workers, and between the exposed group and the MSWI workers (median levels: 0.70 μg/L, 0.81 μg/L, and 1.02 μg/L for the control group, exposed group, and MSWI workers, respectively). The MeHg/T-Hg ratio was 0.51 ± 0.19, 0.59 ± 0.17 and 0.58 ± 0.25, respectively. Multiple linear regression analysis indicated that MeHg concentrations were positively correlated with the gaseous mercury in the air. Combining internal and external exposure assessment showed that the direct contribution of MSWI emissions was minor compared with the dietary contribution. The external and internal exposures were well matched with each other. This study also suggested that an integrated method combining internal and external exposure assessment with an individual-specific questionnaire is feasible to assess the risks for a population living near a MSWI. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Combining rotating-coil measurements of large-aperture accelerator magnets

    CERN Document Server

    AUTHOR|(CDS)2089510

    2016-10-05

    The rotating coil is a widely used tool to measure the magnetic field and the field errors in accelerator magnets. The coil has a length that exceeds the entire magnetic field along the longitudinal dimension of the magnet and gives therefore a two-dimensional representation of the integrated field. Having a very good precision, the rotating coil lacks in versatility. The fixed dimensions make it impractical and inapplicable in situations, when the radial coil dimension is much smaller than the aperture or when the aperture is only little covered by the coil. That being the case for rectangular apertures with large aspect ratio, where a basic measurement by the rotating coil describes the field only in a small area of the magnet. A combination of several measurements at different positions is the topic of this work. Very important for a combination is the error distribution on the measured field harmonics. To preserve the good precision of the higher-order harmonics, the combination must not rely on the main ...

  10. COMPARISONS BETWEEN AND COMBINATIONS OF DIFFERENT APPROACHES TO ACCELERATE ENGINEERING PROJECTS

    Directory of Open Access Journals (Sweden)

    H. Steyn

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: In this article, traditional project management methods such as PERT and CPM, as well as fast-tracking and systems approaches, viz. concurrent engineering and critical chain, are reviewed with specific reference to their contribution to reducing the duration of the execution phase of engineering projects. Each of these techniques has some role to play in the acceleration of project execution. Combinations of approaches are evaluated by considering the potential of sets consisting of two different approaches each. While PERT and CPM approaches have been combined for many years in a technique called PERT/CPM, new combinations of approaches are discussed. Certain assumptions inherent to PERT and often wrong are not made by the critical chain approach.

    AFRIKAANSE OPSOMMING: In hierdie artikel word tradisionele projekbestuurbenaderings soos PERT en CPM asook projekversnelling en stelselbenaderings, naamlik gelyktydige ingenieurswese, en kritiekeketting-ondersoek met betrekking tot die bydrae wat elk tot die versnelling van die uitvoeringsfase van ingenieursprojekte kan lewer. Elk van hierdie benaderings kan ‘n spesifieke bydrae tot die versnelling van projekte lewer. Kombinasies, elk bestaande uit twee verskillende benaderings, word geëvalueer. Terwyl PERT en CPM reeds baie jare lank in kombinasie gebruik word, word nuwe kombinasies ook hier bespreek. Sekere aannames inherent aan die PERT-benadering is dikwels foutief. Hierdie aannames word nie deur die kritieke-ketting-benadering gemaak nie.

  11. Combining valgus knee brace and lateral foot wedges reduces external forces and moments in osteoarthritis patients

    NARCIS (Netherlands)

    Jafarnezhadgero, Amir Ali; Oliveira, Anderson S.; Mousavi, Seyed Hamed; Madadi-Shad, Morteza

    Osteoarthritis progression can be related to the external knee adduction and flexion moments during walking. Lateral foot wedges and knee braces have been used as treatment for osteoarthritis, but little is known about their influence on knee joint moments generated in the sagittal and frontal

  12. Influence of external beam technique and brachytherapy quality assurance on the side effects in the combined external beam- and brachytherapy treatment of local advanced prostate cancer

    International Nuclear Information System (INIS)

    Kovacs, G.; Galalae, R.; Wirth, B.; Bertermann, H.; Wilhelm, R.; Kohr, P.; Kimmig, B.

    1996-01-01

    Transrectal ultrasound(TRUS) guided HDR implantation of the prostate has been established at the Kiel University by Bertermann and Brix in 1986 and there are to date 179 (T1b-T3 No Mo) patients treated in a combined modality. The dose for the implant was 2x 15 Gy on the capsule of the prostate in 14-20 days. For local and regional lymph nodes 20 Gy external beam therapy (AP-PA pelvic portals), 20 Gy with an individual transmission block (100% for subclinical disease, 70% and 50% according to the implant dosimetry for the prostate) and 10 Gy small volume irradiation for the prostate was applied, conventional fractioned. Total dose after the therapy 70 Gy for the prostate and 50 Gy for the subclinical disease in 6-7 weeks. As a quality control method we use since 1991 in vivo dosimetry on the medial rectum wall as well as in the prostatic part of the urethra. Regular follow-up 3-118 months after therapy (median 55) with PSA, digital rectal examination, control TRUS with volumetry (after one year with biopsy) and bone scan. There were no major early side effects within the first three months. Proctitis till 1991 with a duration up to 12 months 49%, prolonging more than one year in 23 %, (total proctitis 72.6%). Dysuria in up to 12 months 30 %, long lasting 30% (total number of dysuria 60 %). Erectile dysfunction in 56 %. Because of the number of the side effects 1991 we changed the external beam technique: instead of the biaxial arch therapy the AP-PA portals, and reduced irradiated volume (from 6480 cm 3 to 5040 cm 3 ). We introduced instead of the small volume arch therapy for 10 Gy external boost the box-technique with shielding the back part of the rectum and the upper part of the bladder resulting additional volume reduction. Through the 15 Gy HDR brachytherapy dose on the prostate capsule there are up to 8 Gy on the medial rectal wall, measured by in vivo dosimetry. This dose could not be responsible for the high number of side effects (see gynecological

  13. Ring accelerators

    International Nuclear Information System (INIS)

    Gisler, G.; Faehl, R.

    1983-01-01

    We present two-dimensional simulations in (r-z) and r-theta) cylinderical geometries of imploding-liner-driven accelerators of rings of charged particles. We address issues of azimuthal and longitudinal stability of the rings. We discuss self-trapping designs in which beam injection and extraction is aided by means of external cusp fields. Our simulations are done with the 2-1/2-D particle-in-cell plasma simulation code CLINER, which combines collisionless, electromagnetic PIC capabilities with a quasi-MHD finite element package

  14. [Mediator processes in the brain structures in the late periods after external and combined exposure to ionizing radiation].

    Science.gov (United States)

    Taĭts, M Iu; Dudina, T V; Kandybo, T S; Elkina, A I

    1990-01-01

    In experiments with mature Wistar male rats it was shown that X-radiation of 12.9 mCi/kg and the combined effect of X-rays and 131I of 6.5 mCi/kg changed the rate of mediator processes in the structures responsible for the hypothalamic function regulation. At remote times (6 months) following irradiation differences were observed in the discoordination of mediator interrelations associated with the peculiarities of the indirect effect of external and combined irradiation implemented via endocrine mechanism system.

  15. Evaluation using Monte Carlo simulations, of the effect of a shielding, called external shielding, for fotoneutrons generated in linear accelerators, using the computational model of Varian accelerator 2300 C/D operating in eight rotation angles of the GA

    International Nuclear Information System (INIS)

    Silva, Hugo R.; Silva, Ademir X.; Rebello, Wilson F.; Silva, Maria G.

    2011-01-01

    This paper aims to present the results obtained by Monte Carlo simulation of the effect of shielding against neutrons, called External Shielding, to be placed on the heads of linear accelerators used in radiotherapy. For this, it was used the radiation transport code Monte Carlo N-Particle - MCNPX, in which were developed computational model of the head of the linear accelerator Varian 2300 C/D. The equipment was simulated within a bunker, operating at energies of 10, 15 and 18 MV, considering the rotation of the gantry at eight different angles ( 0 deg, 45 deg, 90 deg, 135 deg, 180 deg, 225 deg, 270 deg and 315 deg), in all cases, the equipment was modeled without and with the shielding positioned attached to the head of the accelerator on its bottom. In each of these settings, it was calculated the Ambient Dose Equivalent due to neutron H * (10)n on points situated in the region of the patient (region of interest for evaluation of undesirable neutron doses on the patient) and in the maze of radiotherapy room (region of interest for shielding the access door to the bunker). It was observed for all energies of equipment operation as well as for all angles of inclination of the gantry, a significant reduction in the values of H * (10) n when the equipment operated with the external shielding, both in the region of the patient as in the region of the maze. (author)

  16. Californium-252 Brachytherapy Combined With External-Beam Radiotherapy for Cervical Cancer: Long-Term Treatment Results

    International Nuclear Information System (INIS)

    Lei Xin; Qian Chengyuan; Qing Yi; Zhao Kewei; Yang Zhengzhou; Dai Nan; Zhong Zhaoyang; Tang Cheng; Li Zheng; Gu Xianqing; Zhou Qian; Feng Yan; Xiong Yanli; Shan Jinlu; Wang Dong

    2011-01-01

    Purpose: To observe, by retrospective analysis, the curative effects and complications due to californium-252 ( 252 Cf) neutron intracavitary brachytherapy (ICBT) combined with external-beam radiotherapy (EBRT) in the treatment of cervical cancer. Methods and Materials: From February 1999 to December 2007, 696 patients with cervical cancer (Stages IB to IIIB) were treated with 252 Cf-ICBT in combination of EBRT. Of all, 31 patients were at Stage IB, 104 at IIA, 363 at IIB, 64 at IIIA, and 134 at IIIB. Californium-252 ICBT was delivered at 7–12 Gy per insertion per week, with a total dose of 29–45 Gy to reference point A in three to five insertions. The whole pelvic cavity was treated with 8-MV X-ray external irradiation at 2 Gy per fraction, four times per week. After 16–38 Gy of external irradiation, the center of the whole pelvic field was blocked with a 4-cm-wide lead shield, with a total external irradiation dose of 44–56 Gy. The total treatment course was 5 to 6 weeks. Results: Overall survival rate at 3 and 5 years for all patients was 76.0% and 64.9%, respectively. Disease-free 3- and 5-year survival rates of patients were 71.2% and 58.4%, respectively. Late complications included vaginal contracture and adhesion, radiation proctitis, radiation cystitis, and inflammatory bowel, which accounted for 5.8%, 7.1%, 6.2%, and 4.9%, respectively. Univariate analysis results showed significant correlation of stage, age, histopathologic grade, and lymph node status with overall survival. Cox multiple regression analysis showed that the independent variables were stage, histopathologic grade, tumor size, and lymphatic metastasis in all patients. Conclusion: Results of this series suggest that the combined use of 252 Cf-ICBT with EBRT is an effective method for treatment of cervical cancer.

  17. The Effect of Acceleration Sprint and Zig-zag Drill Combination to Increase Students’ Speed and Agility

    Science.gov (United States)

    Bana, O.; Mintarto, E.; Kusnanik, N. W.

    2018-01-01

    The purpose of this research is to analyze the following factors: (1) how far the effect of exercise acceleration sprint on the speed and agility (2) how much influence the zig-zag drill combination to the speed and agility (3) and is there any difference between the effects of exercise acceleration sprint and practice zig-zag drill combination of the speed and agility. This research is quantitative with quasi-experimental approach. The design of this study is matching only design.This study was conducted on 33 male students who take part in extracurricular and divided into 3 groups with 11 students in each group. Group 1 was given training of acceleration sprint, group 2 was given zig-zag training combination drills of conventional and exercises for group 3, for 8 weeks. The data collection was using sprint 30 meter to test the speed and agility t-test to test agility. Data were analyzed using t-test and analysis of variance. The conclusion of the research is (1) there is a significant effect of exercise acceleration sprint for the speed and agility, (2) there is a significant influence combination zig-zag drills, on speed and agility (3) and exercise acceleration sprint have more effect on the speed and agility.

  18. The beam matching system between the preaccelerator and the main accelerator of the Van-de-Graaff cyclotron combination VICKSI

    International Nuclear Information System (INIS)

    Hinderer, G.

    1975-01-01

    The beam matching between the two accelerators of the heavy-ion accelerator combination VICKSI (Van de Graaff Isochron-Cyclotron Kombination fuer schwere Ionen) which is under construction at the Hahn-Meitner-Institut Berlin is investigated. The main elements are a combined gas- and carbon foil-stripper to increase the charge state of the ions and two clystron type high frequency bunchers for matching the longitudinal phase space. In order to minimize the enlargement of phase space due to energy- and angle straggling in the foil stripper a focus in all three dimensions is generated at this position. (orig./WL) [de

  19. Evaluation of magnetic fluid hyperthermia (MFH) combined with external radiation in an orthotopic rat model of prostate cancer

    International Nuclear Information System (INIS)

    Johannsen, M.; Thiesen, B.; Taymoorian, K.; Gneveckow, U.; Waldoefner, N.; Koch, M.; Scholz, R.; Lein, M.; Jung, K.; Loening, S.A.; Jordan, A.

    2005-01-01

    Full text: Magnetic fluid hyperthermia (MFH) is a new concept of cancer treatment based on AC magnetic field-induced excitation of biocompatible superparamagnetic nanoparticles. Preliminary studies of MFH using nanoscaled aminosilan-coated magnetites have demonstrated the feasibility of minimally invasive MFH in the Dunning tumor model. Here we evaluated the effect of two sequential MFH treatments, combined with external radiation, in an orthotopic Dunning R3327-MatLyLu prostate cancer model. MFH led to a significant growth inhibition in this orthotopic model of the aggressive MatLyLu tumor variant. Furthermore, combined MFH and radiation with 20 Gy equally effective in inhibiting tumor growth as radiation with 60 Gy, suggesting a significant synergistic effect. Intratumoral deposition of magnetic fluids was found to be stable, allowing for serial MFH treatments without repeated injection. The optimal treatment schedules of this combination regarding temperatures, sequencing and fractionation need to be defined in further experimental studies. (author)

  20. Morfologic anomalies in the spermatozoid heads caused by isolated and combined effects of external ionizing radiation and chemical factor

    International Nuclear Information System (INIS)

    Shopova, V.; Nechev, Khr.; Sylovski, P.

    1985-01-01

    The test for recording morphologic anomalies in the spermatozoid heads and the genotoxic effect of isolated and combined treatment with the preparation chloracetophone and external ionizing radiation was applied on of mice line C 57 Bl. Evaluation of the morphologic anomalies in the spermatozoa rested upon two staining method, one of which helped to distinguish the acrosome. It was demonstrated that chloracetophone given in a single high dose (1/2 and 1/4 LD 50 ) was genotoxic. Ionizing radiation induced the expected positive effect. After combined application of 5x1/5 LD 50 chloracetophone and 1 and 4 Gy irradiation dose, it was the effect of radiation that was recorded. Only in the group in which both noxious agents were combined in effective doses (1/2 LD 50 chloracetophone and 1 Gy) there was a tendency toward additive effect

  1. Study of ancient Islamic gilded pieces combining PIXE-RBS on external microprobe with sem images

    International Nuclear Information System (INIS)

    Ynsa, M.D.; Gutierrez, P.C.; Enguita, O.; Chamon, J.; Pardo, A.I.; Arroyo, M.; Barrio, J.; Gomez-Morilla, I.; Ferretti, M.; Climent-Font, A.

    2008-01-01

    Numerous metallic objects with very aesthetic and technological qualities have been recovered by archaeological excavations. Adequate processes of restoration and conservation treatments require the accurate determination of the elemental composition and distribution within the objects, as well as the identification of the nature and distribution of the corrosion products. Ideally the identification method should cause no alteration in the sample. In this work, different archaeological pieces with a gilded look have been characterized using simultaneously PIXE and RBS at the CMAM external microprobe in order to study the gilding metalworking done in the Iberian Peninsula during the Middle Ages. The gold layer thickness and its elemental concentrations of Ag, Au and Hg were determined by both techniques and compared with the scanning electron microscopy images obtained for some fragments of pieces. (orig.)

  2. Effect of combined misonidazole and accelerated neon ions on a human melanoma transplanted into nude mice

    International Nuclear Information System (INIS)

    Guichard, M.; Tenforde, T.; Curtis, S.; Malaise, E.P.

    1982-01-01

    The response to accelerated neon ions of human Nall melanomas growing in nude mice was measured by an in vitro colony-forming assay following in situ tumor irradiation in the midposition of a 10-cm extended-peak ionization region. Values of the relative biological effectiveness (RBE) for peak neon ions compared with 60 Coγ radiation were 3.2 and 3.4, respectively, at the 1% and 10% survival levels. Following irradiation with peak neon ions, the repair of potentially lethal damage (PLD) was comparable to that observed after γ irradiation. When misonidazole (1 mg/g intraperitoneal dose) was administered in combination with extended-peak neon ions, the drug enhancement ratio (ER) at the 1% survival level was 1.5 if the tumors were removed and plated in vitro immediately following irradiation, and 1.9 if tumor excision and plating were delayed for greater than or equal to 6 hours. Administration of misonidazole completely inhibited PLD repair following either γ irradiation or extended peak neon-ion irradiation

  3. A combined method to calculate co-seismic displacements through strong motion acceleration baseline correction

    Science.gov (United States)

    Zhan, W.; Sun, Y.

    2015-12-01

    High frequency strong motion data, especially near field acceleration data, have been recorded widely through different observation station systems among the world. Due to tilting and a lot other reasons, recordings from these seismometers usually have baseline drift problems when big earthquake happens. It is hard to obtain a reasonable and precision co-seismic displacement through simply double integration. Here presents a combined method using wavelet transform and several simple liner procedures. Owning to the lack of dense high rate GNSS data in most of region of the world, we did not contain GNSS data in this method first but consider it as an evaluating mark of our results. This semi-automatic method unpacks a raw signal into two portions, a summation of high ranks and a low ranks summation using a cubic B-spline wavelet decomposition procedure. Independent liner treatments are processed against these two summations, which are then composed together to recover useable and reasonable result. We use data of 2008 Wenchuan earthquake and choose stations with a near GPS recording to validate this method. Nearly all of them have compatible co-seismic displacements when compared with GPS stations or field survey. Since seismometer stations and GNSS stations from observation systems in China are sometimes quite far from each other, we also test this method with some other earthquakes (1999 Chi-Chi earthquake and 2011 Tohoku earthquake). And for 2011 Tohoku earthquake, we will introduce GPS recordings to this combined method since the existence of a dense GNSS systems in Japan.

  4. Low-dose-rate intraoperative brachytherapy combined with external beam irradiation in the conservative treatment of soft tissue sarcoma

    International Nuclear Information System (INIS)

    Delannes, M.; Thomas, L.; Martel, P.; Bonnevialle, P.; Stoeckle, E.; Chevreau, Ch.; Bui, B.N.; Daly-Schveitzer, N.; Pigneux, J.; Kantor, G.

    2000-01-01

    Purpose: Conservative treatment of soft tissue sarcomas most often implies combination of surgical resection and irradiation. The aim of this study was to evaluate low-dose-rate intraoperative brachytherapy, delivered as a boost, in the local control of primary tumors, with special concern about treatment complications. Methods and Materials: Between 1986 and 1995, 112 patients underwent intraoperative implant. This report focuses on the group of 58 patients with primary sarcomas treated by combination of conservative surgery, intraoperative brachytherapy, and external irradiation. Most of the tumors were located in the lower limbs (46/58--79%). Median size of the tumor was 10 cm, most of the lesions being T2-T3 (51/58--88%), Grade 2 or 3 (48/58--83%). The mean brachytherapy dose was 20 Gy and external beam irradiation dose 45 Gy. In 36/58 cases, iridium wires had to be placed on contact with neurovascular structures. Results: With a median follow-up of 54 months, the 5-year actuarial survival was 64.9%, with a 5-year actuarial local control of 89%. Of the 6 patients with local relapse, 3 were salvaged. Acute side effects, essentially wound healing problems, occurred in 20/58 patients, late side effects in 16/58 patients (7 neuropathies G2 to G4). No amputation was required. The only significant factor correlated with early side effects was the location of the tumor in the lower limb (p = 0.003), and with late side effects the vicinity of the tumor with neurovascular structures (p = 0.009). Conclusion: Brachytherapy allows early delivery of a boost dose in a reduced volume of tissue, precisely mapped by the intraoperative procedure. Combined with external beam irradiation, it is a safe and efficient treatment technique leading to high local control rates and limited functional impairment

  5. Proposal on the accelerator driven molten-salt reactor (ATW concept) benchmark calculations. (STAGE 1 - without an external neutron source)

    International Nuclear Information System (INIS)

    Svarny, J.; Mikolas, P.

    1999-01-01

    The first stage of ATW neutronic benchmark (without an external source), based on the simple modelling of two component concept is presented. The simple model of two component concept of the ATW (graphite + molten salt system) was found. The main purpose of this benchmark is not only to provide the basic characteristics of given ADS but also to test codes in calculations of the rate of transmutation waste and to evaluate basic kinetics parameters and reactivity effects. (author)

  6. Effectiveness of combined laser-puncture and conventional wound care to accelerate diabetic foot ulcer healing

    Directory of Open Access Journals (Sweden)

    Adiningsih Srilestari

    2017-05-01

    Full Text Available Background: Impaired wound healing is a common complication of diabetes. It has complex pathophysiologic mechanisms and often necessitates amputation. Our study aimed to evaluate the effectiveness of combined laser-puncture and conventional wound care in the treatment of diabetic foot ulcers.Methods: This was a double-blind controlled randomized clinical trial on 36 patients, conducted at the Metabolic Endocrine Outpatient Clinic, Cipto Mangunkusumo Hospital, Jakarta, between May and August 2015. Stimulation by laser-puncture (the treatment group or sham stimulation (the control group were performed on top of the standard wound care. Laser-puncture or sham were done on several acupuncture points i.e. LI4 Hegu, ST36 Zusanli, SP6 Sanyinjiao and KI3 Taixi bilaterally, combined with irradiation on the ulcers itself twice a week for four weeks. The mean reduction in ulcer sizes (week 2–1, week 3–1, week 4–1 were measured every week and compared between the two groups and analyzed by Mann-Whitney test.Results: The initial median ulcer size were 4.75 (0.10–9.94 cm2 and 2.33 (0.90–9.88 cm2 in laser-puncture and sham groups, respectively (p=0.027. The median reduction of ulcer size at week 2–1 was -1.079 (-3.25 to -0.09 vs -0.36 (-0.81 to -1.47 cm2, (p=0.000; at week 3–1 was -1.70 (-3.15 to -0.01 vs -0.36 (-0.80 to -0.28 cm2, (p=0.000; and at week 4–1 was -1.22 (-2.72 to 0.00 vs -0.38 (-0.74 to -0.57 cm2, (p=0.012.Conclusion: Combined laser-puncture and conventional wound care treatment are effective in accelerating the healing of diabetic foot ulcer.

  7. Combined gold seed implantation and external radiotherapy for stage B2 or C prostate cancer

    International Nuclear Information System (INIS)

    Carey, P.O.; Lippert, M.C.; Constable, W.C.; Jones, D.; Talton, B.M.

    1988-01-01

    Patients with clinical stage B2 or C prostatic carcinoma represent a group for which there are several treatment options. We followed the course and outcome of 72 patients with clinical stages B and C prostate cancer who were treated with surgical staging, insertion of gold grains and external radiation at our institutions between 1975 and 1984. Of the patients 44 (61 per cent) had clinical stage B disease and the majority (89 per cent) of these were stage B2 lesions. The remaining 28 patients (39 per cent) had clinical stage C tumors. In our series 27 per cent of the clinical stage B and 68 per cent of the clinical stage C cancer patients had positive lymph nodes. The 5-year survival free of disease was 52 per cent for patients with both stages of disease. The 7-year survival free of disease was 47 per cent for patients with clinical stage B and 14 per cent for those with clinical stage C cancer. Lymph node status did not have a statistically significant effect on total survival but survival free of disease correlated significantly with node status. Local treatment failures were defined as patients who required transurethral prostatic resection or orchiectomy for palliation of obstructive symptoms related to local tumor regrowth. By these criteria we prevented local progression in 78 per cent of the patients at 5 years

  8. Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts

    International Nuclear Information System (INIS)

    Park, Sang Soon; Lee, Min Woo

    2014-01-01

    Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were investigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition

  9. One-visit endodontic retreatment of combined external/internal root resorption using a calcium-enriched mixture.

    Science.gov (United States)

    Asgary, Saeed; Ahmadyar, Maryam

    2012-01-01

    Combined external and internal root resorption (ERR/IRR) is a rare endodontic disease that leads to alteration of the root canal anatomy. This report describes the management of an endodontically failed molar that was severely affected by ERR/IRR. Radiographic examination demonstrated inadequate obturation of the root canals associated with ERR/IRR and a large periradicular lesion. During nonsurgical endodontic retreatment, the root canals were subjected to conventional chemomechanical debridement. In the same session, the entire distal root canal was obturated using a calcium-enriched mixture (CEM) cement, and the mesial canals were obturated with gutta-percha/sealer. The clinical findings and follow-up radiographs indicated favorable treatment outcomes after 12 months. One-visit application of CEM cement could be a successful approach for the management of combined ERR/IRR.

  10. Combined external-beam PIXE and {mu}-Raman characterisation of garnets used in Merovingian jewellery

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: thomas.calligaro@culture.gouv.fr; Colinart, S.; Poirot, J.-P.; Sudres, C

    2002-04-01

    Red garnets were the dominant gemstones used for jewels in Europe during the Early Middle Ages. We have studied over 350 garnets set on 12 jewels unearthed in the royal necropolis of the Saint-Denis Basilica, close to Paris. This famous collection of 'cloisonne' style artefacts dates from the Merovingian period (late fifth century AD to early seventh century AD). The archaeological issue addressed is the identification of the geographical origin of these garnets, in view to establish the gem trading routes during the Dark Ages. External beam PIXE was used to determine the major constituents (Mg, Al, Si, Ca, Mn, Fe), specifying the garnet type (composition in various mineralogical end-members, e.g. almandine, pyrope, spessartite, ...), and the trace element content (Cr, Y). Three sorts of garnets were identified. Ten jewels are adorned with almandine garnets (Fe-rich). One jewel has intermediate almandine-pyrope garnets ('rhodolite'). The last and most recent jewel is inlaid with pyrope (Mg-rich) garnets. Trace element content and slight differences in major composition allowed to distinguish five different sources: two sources for pyrope garnets (with and without chromium), and two sources for almandine garnets (distinctive calcium, magnesium and yttrium contents). A preliminary comparison with literature data suggested that almandine garnets may have been mined from India while the 'rhodolite' garnets may have been imported from Sri Lanka. The sources of pyrope garnets could be the Bohemian deposits (Czech republic). In addition, {mu}-Raman spectrometry was used to identify most of the mineral inclusions (apatite, zircon, ilmenite, monazite, calcite, quartz) present in almandine garnets. Even if two specific types of inclusions were not identified, due to the lack of corresponding reference spectra in our database, the Raman spectra collected provided an interesting inclusion fingerprint.

  11. Nonlinear Dynamic Behavior of a Flexible Structure to Combined External Acoustic and Parametric Excitation

    Directory of Open Access Journals (Sweden)

    Paulo S. Varoto

    2006-01-01

    Full Text Available Flexible structures are frequently subjected to multiple inputs when in the field environment. The accurate determination of the system dynamic response to multiple inputs depends on how much information is available from the excitation sources that act on the system under study. Detailed information include, but are not restricted to appropriate characterization of the excitation sources in terms of their variation in time and in space for the case of distributed loads. Another important aspect related to the excitation sources is how inputs of different nature contribute to the measured dynamic response. A particular and important driving mechanism that can occur in practical situations is the parametric resonance. Another important input that occurs frequently in practice is related to acoustic pressure distributions that is a distributed type of loading. In this paper, detailed theoretical and experimental investigations on the dynamic response of a flexible cantilever beam carrying a tip mass to simultaneously applied external acoustic and parametric excitation signals have been performed. A mathematical model for transverse nonlinear vibration is obtained by employing Lagrange’s equations where important nonlinear effects such as the beam’s curvature and quadratic viscous damping are accounted for in the equation of motion. The beam is driven by two excitation sources, a sinusoidal motion applied to the beam’s fixed end and parallel to its longitudinal axis and a distributed sinusoidal acoustic load applied orthogonally to the beam’s longitudinal axis. The major goal here is to investigate theoretically as well as experimentally the dynamic behavior of the beam-lumped mass system under the action of these two excitation sources. Results from an extensive experimental work show how these two excitation sources interacts for various testing conditions. These experimental results are validated through numerically simulated results

  12. [Surgical treatment for talar neck fracture of Hawkins III, IV type with compression hollow screws combined with external fixator].

    Science.gov (United States)

    Wang, Xian-Xun; Wan, Chang-Tao; Yu, Li

    2017-05-25

    To investigate the clinical effects of compression hollow screws combined with external fixator in treating talar neck fracture of Hawkins III, IV type. From March 2010 to August 2014, 15 patients with talar neck fractures of Hawkins III, IV type were treated by open reduction and compression hollow screws fixation complicated with external fixator fixation. Including 9 males and 6 females, aged from 17 to 65 years old with an average of 37.5 years old. There were 9 cases of Hawkins III and 6 cases of Hawkins IV type. Postoperative radiographs and CT of ankle were used to evaluate the fracture healing and talar necrosis. The function of ankle and foot were evaluated by American Society of Ankle and Foot Surgery(AOFAS). All the patients were followed up for 8 to 55 months with an average of 23.5 months and all fractures got bone healing from 13 to 38 weeks with an average of (17.99±6.81) weeks. Traumatic arthritis occurred in 7 cases and talar necrosis in 6 cases (2 cases of type III and 4 cases of type IV) after operation. The average AOFAS score was 61.80±18.75, including excellent in 4 cases, good in 2 cases, fair in 4 cases and poor in 5 cases. Talar neck fracture with Hawkins III, IV type has large possibility to develop avascular necrosis. Hollow compression screw combined with external fixation may late weight-bearing for ankle and can sufficiently guarantee bone healing time, and achieve good results for the treatment of talar neck fracture.

  13. External beam radiotherapy alone or combined with high-dose-rate intracavitary irradiation in the treatment of cancer of the esophagus

    International Nuclear Information System (INIS)

    Hishikawa, Y.; Taniguchi, M.; Kamikonya, N.; Tanaka, S.; Miura, T.

    1988-01-01

    Autopsy findings of 35 patients, treated with radiotherapy for an esophageal carcinoma, were reviewed. A residual tumor was seen at autopsy in 7 of 16 patients treated with high-dose-rate intracavitary irradiation following external irradiation, in 13 of 14 patients treated with external irradiation of 50 Gy or more, and in all 5 patients treated with external irradiation of less than 50 Gy. Incidence on lymph node metastasis, at autopsy, did not diifer between the combined radiotherapy group and the external irradiation groups. However, it correlated with disease stage. It was observed in 11 of 17 patients with Stage 1 and Stage 2 disease, compared to 17 of 18 patients with Stage 3 and Stage 4 disease. Distant organ metastasis, at autopsy, also did not differ between the combined radiotherapy group and the external irradiation groups, and was also correlated with disease stage. It was found in 8 of 17 patients with Stage 1 and Stage 2 disease, compared to all 18 patients with Stage 3 and Stage 4 disease. Mean survival was different between the patients treated by high-dose-rate intracavitary irradiation following external irradiation and those treated by external irradiation alone; 11.3 months in the 16 patients treated with combined therapy, as compared to 6.9 months in the 14 patients who received external irradiation of 50 Gy or more, and 3.6 months in the 5 patients who received external irradiation of less than 50 Gy. 6 refs.; 5 tabs

  14. American Brachytherapy Society Task Group Report: Combination of brachytherapy and external beam radiation for high-risk prostate cancer.

    Science.gov (United States)

    Spratt, Daniel E; Soni, Payal D; McLaughlin, Patrick W; Merrick, Gregory S; Stock, Richard G; Blasko, John C; Zelefsky, Michael J

    To review outcomes for high-risk prostate cancer treated with combined modality radiation therapy (CMRT) utilizing external beam radiation therapy (EBRT) with a brachytherapy boost. The available literature for high-risk prostate cancer treated with combined modality radiation therapy was reviewed and summarized. At this time, the literature suggests that the majority of high-risk cancers are curable with multimodal treatment. Several large retrospective studies and three prospective randomized trials comparing CMRT to dose-escalated EBRT have demonstrated superior biochemical control with CMRT. Longer followup of the randomized trials will be required to determine if this will translate to a benefit in metastasis-free survival, disease-specific survival, and overall survival. Although greater toxicity has been associated with CMRT compared to EBRT, recent studies suggest that technological advances that allow better definition and sparing of critical adjacent structures as well as increasing experience with brachytherapy have improved implant quality and the toxicity profile of brachytherapy. The role of androgen deprivation therapy is well established in the external beam literature for high-risk disease, but there is controversy regarding the applicability of these data in the setting of dose escalation. At this time, there is not sufficient evidence for the omission of androgen deprivation therapy with dose escalation in this population. Comparisons with surgery remain limited by differences in patient selection, but the evidence would suggest better disease control with CMRT compared to surgery alone. Due to a series of technological advances, modern combination series have demonstrated unparalleled rates of disease control in the high-risk population. Given the evidence from recent randomized trials, combination therapy may become the standard of care for high-risk cancers. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All

  15. Combination of peptide receptor radionuclide therapy with fractionated external beam radiotherapy for treatment of advanced symptomatic meningioma

    International Nuclear Information System (INIS)

    Kreissl, Michael C; Flentje, Michael; Sweeney, Reinhart A; Hänscheid, Heribert; Löhr, Mario; Verburg, Frederik A; Schiller, Markus; Lassmann, Michael; Reiners, Christoph; Samnick, Samuel S; Buck, Andreas K

    2012-01-01

    External beam radiotherapy (EBRT) is the treatment of choice for irresectable meningioma. Due to the strong expression of somatostatin receptors, peptide receptor radionuclide therapy (PRRT) has been used in advanced cases. We assessed the feasibility and tolerability of a combination of both treatment modalities in advanced symptomatic meningioma. 10 patients with irresectable meningioma were treated with PRRT ( 177 Lu-DOTA0,Tyr3 octreotate or - DOTA0,Tyr3 octreotide) followed by external beam radiotherapy (EBRT). EBRT performed after PRRT was continued over 5–6 weeks in IMRT technique (median dose: 53.0 Gy). All patients were assessed morphologically and by positron emission tomography (PET) before therapy and were restaged after 3–6 months. Side effects were evaluated according to CTCAE 4.0. Median tumor dose achieved by PRRT was 7.2 Gy. During PRRT and EBRT, no side effects > CTCAE grade 2 were noted. All patients reported stabilization or improvement of tumor-associated symptoms, no morphologic tumor progression was observed in MR-imaging (median follow-up: 13.4 months). The median pre-therapeutic SUV max in the meningiomas was 14.2 (range: 4.3–68.7). All patients with a second PET after combined PRRT + EBRT showed an increase in SUV max (median: 37%; range: 15%–46%) to a median value of 23.7 (range: 8.0–119.0; 7 patients) while PET-estimated volume generally decreased to 81 ± 21% of the initial volume. The combination of PRRT and EBRT is feasible and well tolerated. This approach represents an attractive strategy for the treatment of recurring or progressive symptomatic meningioma, which should be further evaluated

  16. High biologically effective dose radiation therapy using brachytherapy in combination with external beam radiotherapy for high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Keisei Okamoto

    2017-02-01

    Full Text Available Purpose : To evaluate the outcomes of high-risk prostate cancer patients treated with biologically effective dose (BED ≥ 220 Gy of high-dose radiotherapy, using low-dose-rate (LDR brachytherapy in combination with external beam radiotherapy (EBRT and short-term androgen deprivation therapy (ADT. Material and methods : From 2005 to 2013, a total of 143 patients with high-risk prostate cancer were treated by radiotherapy of BED ≥ 220 Gy with a combination of LDR brachytherapy, EBRT, and androgen deprivation therapy (ADT. The high-risk patients in the present study included both high-risk and very high-risk prostate cancer. The number of high-risk features were: 60 patients with 1 high-risk factor (42%, 61 patients with 2 high-risk factors (43%, and 22 patients with 3 high-risk factors (15% including five N1 disease. External beam radiotherapy fields included prostate and seminal vesicles only or whole pelvis depending on the extension of the disease. Biochemical failure was defined by the Phoenix definition. Results : Six patients developed biochemical failure, thus providing a 5-year actual biochemical failure-free survival (BFFS rate of 95.2%. Biochemical failure was observed exclusively in cases with distant metastasis in the present study. All six patients with biochemical relapse had clinical failure due to bone metastasis, thus yielding a 5-year freedom from clinical failure (FFCF rate of 93.0%. None of the cases with N1 disease experienced biochemical failure. We observed four deaths, including one death from prostate cancer, therefore yielding a cause-specific survival (CSS rate of 97.2%, and an overall survival (OS rate of 95.5%. Conclusions : High-dose (BED ≥ 220 Gy radiotherapy by LDR in combination with EBRT has shown an excellent outcome on BFFS in high-risk and very high-risk cancer, although causal relationship between BED and BFFS remain to be explained further.

  17. SU-E-T-554: Comparison of Electron Disequilibrium Factor in External Photon Beams for Different Models of Linear Accelerators

    International Nuclear Information System (INIS)

    LIU, B; Zhu, T

    2014-01-01

    Purpose: The dose in the buildup region of a photon beam is usually determined by the transport of the primary secondary electrons and the contaminating electrons from accelerator head. This can be quantified by the electron disequilibrium factor, E, defined as the ratio between total dose and equilibrium dose (proportional to total kerma), E = 1 in regions beyond buildup region. Ecan be different among accelerators of different models and/or manufactures of the same machine. This study compares E in photon beams from different machine models/ Methods: Photon beam data such as fractional depth dose curve (FDD) and phantom scatter factors as a function of field size and phantom depth were measured for different Linac machines. E was extrapolated from these fractional depth dose data while taking into account inverse-square law. The ranges of secondary electron were chosen as 3 and 6 cm for 6 and 15 MV photon beams, respectively. The field sizes range from 2x2 to 40x40 cm 2 . Results: The comparison indicates the standard deviations of electron contamination among different machines are about 2.4 - 3.3% at 5 mm depth for 6 MV and 1.2 - 3.9% at 1 cm depth for 15 MV for the same field size. The corresponding maximum deviations are 3.0 - 4.6% and 2 - 4% for 6 and 15 MV, respectively. Both standard and maximum deviations are independent of field sizes in the buildup region for 6 MV photons, and slightly decreasing with increasing field size at depths up to 1 cm for 15 MV photons. Conclusion: The deviations of electron disequilibrium factor for all studied Linacs are less than 3% beyond the depth of 0.5 cm for the photon beams for the full range of field sizes (2-40 cm) so long as they are from the same manufacturer

  18. Combined Transverse Steel-External FRP Confinement Model for Rectangular Reinforced Concrete Columns

    Directory of Open Access Journals (Sweden)

    Ahmed Al-Rahmani

    2016-02-01

    Full Text Available Recently, the need to increase the strength of reinforced concrete members has become a subject that civil engineers are interested in tackling. Of the many proposed solutions, fiber-reinforced polymer (FRP materials have attracted attention due to their superior properties, such as high strength-to-weight ratio, high energy absorption and excellent corrosion resistance. FRP wrapping of concrete columns is done to enhance the ultimate strength due to the confinement effect, which is normally induced by steel ties. The existence of the two confinement systems changes the nature of the problem, thus necessitating specialized nonlinear analysis to obtain the column’s ultimate capacity. Existing research focused on a single confinement system. Furthermore, very limited research on rectangular sections was found in the literature. In this work, a model to estimate the combined behavior of the two systems in rectangular columns is proposed. The calculation of the effective lateral pressure is based on the Lam and Teng model and the Mander model for FRP wraps and steel ties, respectively. The model then generates stress-strain diagrams for both the concrete core and the cover. The model was developed for the analysis in extreme load events, where all possible contributions to the column’s ultimate capacity should be accounted for without any margin of safety. The model was validated against experiments, and the results obtained showed good agreement with almost all of the available experimental data.

  19. Combined therapy involving hepatic arterial chemoinfusion through a percutaneously implanted port, and external irradiation for advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Jong Won; Suh, Sang Hyun; Won, Jong Yun

    2002-01-01

    To evaluate the efficacy of combined therapy involving intra-arterial hepatic chemoinfusion through a percutaneously implanted port and external irradiation for the treatment of advanced hepatocellular carcinoma. Fifteen patients (2 males and 3 females; mean age=47.5 years) with advanced hepatocellular carcinoma localized in one lobe and with portal vein thrombosis (stage IVa) were included in this study. To permit chemoinfusion through the hepatic artery, a chemoport was implanted percutaneously in the right inguinal area via the femoral artery. Initial external radiation therapy lasted five weeks (44 Gy in a daily fraction of 1.8 Gy), with concurrent intra-arterial hepatic infusion of 5-fluorouracil. This initial treatment was followed by five cycles of intra-arterial hepatic infusion of cisplatin and 5-fluorouracil for three consecutive days every month.Two and six months after treatment was begun, the patients underwent CT scanning and angiography, and their response was assessed in terms of change in tumor size and vascularity, the degree of portal vein thrombosis and arterio-portal shunt, and alpha-fetoprotein levels. Any complications arising from this combined therapy and the clinical status of each patient were also followed up during the treatment period. The response rates at months 2 and 6 were 60% and 33.3%, respectively. One patient (6.7%) showed complete remission, and serum alpha-fetoprotein levels decreased significantly in all patients who responded. In five of the twelve patients, the thrombi in the main portal vein showed marked regression. The one-year survival rate was 30% and the median survival period was 10.6 (range, 3.7 to 28) months. The complications arising after treatment involved the catheter-port system (n=2) or were due to gastroduodenitis (n=9). In these patients with advanced hepatocellular carcinoma and portal vein thronbosis, combined therapy involving hepatic arterial chemoinfusion through a chemoport and external irradiation

  20. Combined therapy involving hepatic arterial chemoinfusion through a percutaneously implanted port, and external irradiation for advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Jong Won; Suh, Sang Hyun; Won, Jong Yun; Lee, Do Yun; Park, Sung Il; Lee, Jong Tae; Moon, Young Myoung; Chon, Chae Yoon; Han, Kwang Hyup; Seoung, Jin Sil

    2002-01-01

    To evaluate the efficacy of combined therapy involving intra-arterial hepatic chemoinfusion through a percutaneously implanted port and external irradiation for the treatment of advanced hepatocellular carcinoma. Fifteen patients (12 males and 3 females; mean age = 47.5 years) with advanced hepatocellular carcinoma localized in one lobe and with portal vein thrombosis (stage IVa) were included in this study. To permit chemoinfusion through the hepatic artery, a Chemoport was implanted percutaneously in the right inguinal area via the femoral artery. Initial external radiation therapy lasted five weeks (44 Gy in a daily fraction of 1.8 Gy), with concurrent intra-arterial hepatic infusion of 5-fluorouracil. This initial treatment was followed by five cycles of intra-arterial hepatic infusion of cisplatin and 5-fluorouracil for three consecutive days every month. Two and six months after treatment was begun, the patients underwent CT scanning and angiography, and their response was assessed in terms of change in tumor size and vascularity, the degree of portal vein thrombosis and arterio-portal shunt, and alpha-fetoprotein levels. Any complications arising from this combined therapy and the clinical status of each patient were also followed up during the treatment period. The response rates at months 2 and 6 were 60% and 33.3%, respectively. One patient (6.7%) showed complete remission, and serum alpha-fetoprotein levels decreased significantly in all patients who responded. In five of the twelve patients, the thrombi in the main portal vein showed marked regression. The one-year survival rate was 30% and the median survival period was 10.6 (range, 3.7 to 28) months. The complications arising after treatment involved the catheter-port system (n=2) or were due to gastroduodenitis (n=9). In these patients with advanced hepatocellular carcinoma and portal vein thronbosis, combined therapy involving hepatic arterial chemoinfusion through a chemoport and external

  1. Combined therapy involving hepatic arterial chemoinfusion through a percutaneously implanted port, and external irradiation for advanced hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Won; Suh, Sang Hyun; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)] [and others

    2002-12-01

    To evaluate the efficacy of combined therapy involving intra-arterial hepatic chemoinfusion through a percutaneously implanted port and external irradiation for the treatment of advanced hepatocellular carcinoma. Fifteen patients (2 males and 3 females; mean age=47.5 years) with advanced hepatocellular carcinoma localized in one lobe and with portal vein thrombosis (stage IVa) were included in this study. To permit chemoinfusion through the hepatic artery, a chemoport was implanted percutaneously in the right inguinal area via the femoral artery. Initial external radiation therapy lasted five weeks (44 Gy in a daily fraction of 1.8 Gy), with concurrent intra-arterial hepatic infusion of 5-fluorouracil. This initial treatment was followed by five cycles of intra-arterial hepatic infusion of cisplatin and 5-fluorouracil for three consecutive days every month.Two and six months after treatment was begun, the patients underwent CT scanning and angiography, and their response was assessed in terms of change in tumor size and vascularity, the degree of portal vein thrombosis and arterio-portal shunt, and alpha-fetoprotein levels. Any complications arising from this combined therapy and the clinical status of each patient were also followed up during the treatment period. The response rates at months 2 and 6 were 60% and 33.3%, respectively. One patient (6.7%) showed complete remission, and serum alpha-fetoprotein levels decreased significantly in all patients who responded. In five of the twelve patients, the thrombi in the main portal vein showed marked regression. The one-year survival rate was 30% and the median survival period was 10.6 (range, 3.7 to 28) months. The complications arising after treatment involved the catheter-port system (n=2) or were due to gastroduodenitis (n=9). In these patients with advanced hepatocellular carcinoma and portal vein thronbosis, combined therapy involving hepatic arterial chemoinfusion through a chemoport and external irradiation

  2. Proposed research on class I components to test a general approach to accelerated aging under combined stress environments

    International Nuclear Information System (INIS)

    Gillen, K.T.; Salazar, E.A.; Frank, C.W.

    1977-04-01

    This report summarizes research on the aging of Class I components in environments representative of nuclear power plants. It discusses Class IE equipment used in nuclear power plants, typical environments encountered by Class IE components, and aging techniques used to qualify this equipment. General discussions of radiation chemistry of polymers and accelerated aging techniques are also included. Based on the inadequacies of present aging techniques for Class IE equipment, a proposal for an experimental program on electrical cables is presented. One of the main purposes of the proposed work is to obtain relevant data in two areas of particular concern--the effect of radiation dose rate on polymer degradation, and the importance of synergism for combined thermal and radiation environments. A new model that allows combined environment accelerated aging to be carried out is introduced, and it is shown how the experimental data to be generated can be used to test this model

  3. LINEAR ACCELERATOR

    Science.gov (United States)

    Christofilos, N.C.; Polk, I.J.

    1959-02-17

    Improvements in linear particle accelerators are described. A drift tube system for a linear ion accelerator reduces gap capacity between adjacent drift tube ends. This is accomplished by reducing the ratio of the diameter of the drift tube to the diameter of the resonant cavity. Concentration of magnetic field intensity at the longitudinal midpoint of the external sunface of each drift tube is reduced by increasing the external drift tube diameter at the longitudinal center region.

  4. A randomised prospective study of two different combined internal and external fixation techniques for distal tibia shaft fractures.

    Science.gov (United States)

    Sun, Liao-Jun; Yu, Xian-Bin; Dai, Cheng-Qian; Hu, Wei; Guo, Xiao-Shan; Chen, Hua

    2014-12-01

    External fixation combined with limited open reduction and internal fixation (EF + LORIF) is a well-accepted and effective method for distal tibia shaft fractures, but it was also related to complications. The objective of this study was to compare external fixation combined with closed reduction and internal fixation (EF + CRIF) with EF + LORIF in the treatment of distal tibia shaft fractures, and explore the benefits and defects of these two techniques. Fifty-six patients were randomised to operative stabilisation either by an external fixator combined with two closed titanium elastic nails or by external fixation combined with limited open reduction and internal fixation. Pre-operative variables included the patients’ age, sex, the affected side, cause of injury, Tscherne classification of soft tissue injury, fracture pattern, and time from injury to surgery. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems and other complications, union time, time of recovery to work, the functional American Orthopaedic Foot and Ankle surgery (AOFAS) score. There was no significant difference in the mean operating time (72.6 ± 11.5 vs. 78.5 ± 16.4 min, P = 0.125), the time to union (21.2 ± 11.0 vs. 22.5 ± 12.3 weeks, P = 0.678), the time of recovery to work (25.0 ± 14.5 vs. 26.4 ± 13.6 weeks, P = 0.711), pin track infection (3/28 vs. 4/28, P = 1.000), delayed union (2/28 vs. 3/28, P = 1.000), pain (38.3 ± 1.6 vs. 38.7 ± 1.5, P = 0.339), function (44.4 ± 6.0 vs. 45.0 ± 5.5, P = 0.698), and total AOFAS scores (91.5 ± 7.4 vs. 93.4 ± 6.8, P = 0.322) between the two groups. However, the mean radiation time was longer in the EF + CRIF group than in the EF + LORIF group (2.0 ± 1.2 vs. 0.3 ± 0.1 min, P alignment was obtained in 50 patients (22 in EF + CRIF vs. 28 in EF + LORIF, P = 0.023). Two cases with EF + CRIF had a 6 degrees of recurvatum deformity and four had 6–9 degrees of valgus deformity

  5. Evaluation of internal and external doses from $^{11}C$ produced in the air in high energy proton accelerator tunnels

    CERN Document Server

    Endo, A; Kanda, Y; Oishi, T; Kondo, K

    2001-01-01

    Air has been irradiated with high energy protons at the 12 GeV proton synchrotron to obtain the following parameters essential for the internal dose evaluation from airborne /sup 11/C produced through nuclear spallation reactions: the abundance of gaseous and particulate /sup 11/C, chemical forms, and particle size distribution. It was found that more than 98% of /sup 11/C is present as gas and the rest is aerosol. The gaseous components were only /sup 11/CO and /sup 11/CO/sub 2/ and their proportions were approximately 80% and 20%, respectively. The particulate /sup 11/C was found to be sulphate and/or nitrate aerosols having a log-normal size distribution; the measurement using a diffusion battery showed a geometric mean radius of 0.035 mu m and a geometric standard deviation of 1.8 at a beam intensity of 6.8*10/sup 11/ proton.pulse /sup -1/ and an irradiation time of 9.6 min. By taking the chemical composition and particle size into account, effective doses both from internal and from external exposures pe...

  6. Accelerated anaerobic hydrolysis rates under a combination of intermittent aeration and anaerobic conditions

    DEFF Research Database (Denmark)

    Jensen, T. R.; Lastra Milone, T.; Petersen, G.

    2017-01-01

    Anaerobic hydrolysis in activated return sludge was investigated in laboratory scale experiments to find if intermittent aeration would accelerate anaerobic hydrolysis rates compared to anaerobic hydrolysis rates under strict anaerobic conditions. The intermittent reactors were set up in a 240 h...... for calculating hydrolysis rates based on soluble COD were compared. Two-way ANOVA with the Bonferroni post-test was performed in order to register any significant difference between reactors with intermittent aeration and strictly anaerobic conditions respectively. The experiment demonstrated a statistically...... significant difference in favor of the reactors with intermittent aeration showing a tendency towards accelerated anaerobic hydrolysis rates due to application of intermittent aeration. The conclusion of the work is thus that intermittent aeration applied in the activated return sludge process (ARP) can...

  7. Minimally invasive surgical technique: Percutaneous external fixation combined with titanium elastic nails for selective treatment of tibial fractures.

    Science.gov (United States)

    Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei

    2015-12-01

    Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Breast conserving surgery in combination with intraoperative radiotherapy after previous external beam therapy: an option to avoid mastectomy.

    Science.gov (United States)

    Thangarajah, F; Heilmann, J; Malter, W; Kunze, S; Marnitz, S; Mallmann, P; Wenz, F; Sperk, E

    2018-04-01

    Mastectomy is the standard procedure in patients with in-breast tumor recurrence (IBTR) or breast cancer after irradiation of the chest due to Hodgkin's disease. In certain cases a second breast conserving surgery (BCS) in combination with intraoperative radiotherapy (IORT) is possible. To date, data concerning BCS in combination with IORT in pre-irradiated patients are limited. This is the first pooled analysis of this special indication with a mature follow-up of 5 years. Patients with IBTR after external beam radiotherapy (EBRT; treated in two centers) for breast cancer were included. Patients with previous EBRT including the breast tissue due to other diseases were also included. IORT was performed with the Intrabeam™-device using low kV X-rays. Clinical data including outcome for all patients and toxicity for a representative cohort (LENT-SOMA scales) were obtained. Statistical analyses were done including Kaplan-Meier estimates for local recurrence, distant metastasis and overall survival. A total of 41 patients were identified (39 patients with IBTR, 2 with Hodgkin`s disease in previous medical history). Median follow-up was 58 months (range 4-170). No grade 3/4 acute toxicity occurred within 9 weeks. Local recurrence-free survival rate was 89.9% and overall survival was 82.7% at 5 years. Seven patients developed metastasis within the whole follow-up. BCS in combination with IORT in IBTR in pre-irradiated patients is a feasible method to avoid mastectomy with a low risk of side effects and an excellent local control and good overall survival.

  9. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling

    International Nuclear Information System (INIS)

    Heilmaier, Christina; Nassenstein, Kai; Nielles-Vallespin, Sonia; Zuehlsdorff, Sven; Hunold, Peter; Barkhausen, Joerg

    2010-01-01

    Purpose: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). Materials and methods: 33 consecutive patients were examined on a 1.5 T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5 m; flip angle (FA), 60 o ; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. Results: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15 s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P 0.121). In both readers and for all parameters variances did not differ significantly (P ≥ 0.409) and the two approaches showed an excellent linear correlation (r > 0.951). Conclusion: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.

  10. External Beam Accelerated Partial-Breast Irradiation Using 32 Gy in 8 Twice-Daily Fractions: 5-Year Results of a Prospective Study

    International Nuclear Information System (INIS)

    Pashtan, Itai M.; Recht, Abram; Ancukiewicz, Marek; Brachtel, Elena; Abi-Raad, Rita F.; D'Alessandro, Helen A.; Levy, Antonin; Wo, Jennifer Y.; Hirsch, Ariel E.; Kachnic, Lisa A.; Goldberg, Saveli; Specht, Michelle; Gadd, Michelle; Smith, Barbara L.; Powell, Simon N.; Taghian, Alphonse G.

    2012-01-01

    Purpose: External beam accelerated partial breast irradiation (APBI) is an increasingly popular technique for treatment of patients with early stage breast cancer following breast-conserving surgery. Here we present 5-year results of a prospective trial. Methods and Materials: From October 2003 through November 2005, 98 evaluable patients with stage I breast cancer were enrolled in the first dose step (32 Gy delivered in 8 twice-daily fractions) of a prospective, multi-institutional, dose escalation clinical trial of 3-dimensional conformal external beam APBI (3D-APBI). Median age was 61 years; median tumor size was 0.8 cm; 89% of tumors were estrogen receptor positive; 10% had a triple-negative phenotype; and 1% had a HER-2-positive subtype. Median follow-up was 71 months (range, 2-88 months; interquartile range, 64-75 months). Results: Five patients developed ipsilateral breast tumor recurrence (IBTR), for a 5-year actuarial IBTR rate of 5% (95% confidence interval [CI], 1%-10%). Three of these cases occurred in patients with triple-negative disease and 2 in non-triple-negative patients, for 5-year actuarial IBTR rates of 33% (95% CI, 0%-57%) and 2% (95% CI, 0%-6%; P<.0001), respectively. On multivariable analysis, triple-negative phenotype was the only predictor of IBTR, with borderline statistical significance after adjusting for tumor grade (P=.0537). Conclusions: Overall outcomes were excellent, particularly for patients with estrogen receptor-positive disease. Patients in this study with triple-negative breast cancer had a significantly higher IBTR rate than patients with other receptor phenotypes when treated with 3D-APBI. Larger, prospective 3D-APBI clinical trials should continue to evaluate the effect of hormone receptor phenotype on IBTR rates.

  11. External Beam Accelerated Partial-Breast Irradiation Using 32 Gy in 8 Twice-Daily Fractions: 5-Year Results of a Prospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Pashtan, Itai M. [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Recht, Abram [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Boston, Massachusetts (United States); Ancukiewicz, Marek [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Brachtel, Elena [Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts (United States); Abi-Raad, Rita F. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); D' Alessandro, Helen A. [Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts (United States); Levy, Antonin; Wo, Jennifer Y. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Hirsch, Ariel E. [Department of Radiation Oncology, Boston Medical Center, Boston University School of Medicine, Boston, Massachusetts (United States); Kachnic, Lisa A. [Department of Surgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Goldberg, Saveli [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Specht, Michelle; Gadd, Michelle; Smith, Barbara L. [Department of Surgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Powell, Simon N. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Taghian, Alphonse G., E-mail: ataghian@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2012-11-01

    Purpose: External beam accelerated partial breast irradiation (APBI) is an increasingly popular technique for treatment of patients with early stage breast cancer following breast-conserving surgery. Here we present 5-year results of a prospective trial. Methods and Materials: From October 2003 through November 2005, 98 evaluable patients with stage I breast cancer were enrolled in the first dose step (32 Gy delivered in 8 twice-daily fractions) of a prospective, multi-institutional, dose escalation clinical trial of 3-dimensional conformal external beam APBI (3D-APBI). Median age was 61 years; median tumor size was 0.8 cm; 89% of tumors were estrogen receptor positive; 10% had a triple-negative phenotype; and 1% had a HER-2-positive subtype. Median follow-up was 71 months (range, 2-88 months; interquartile range, 64-75 months). Results: Five patients developed ipsilateral breast tumor recurrence (IBTR), for a 5-year actuarial IBTR rate of 5% (95% confidence interval [CI], 1%-10%). Three of these cases occurred in patients with triple-negative disease and 2 in non-triple-negative patients, for 5-year actuarial IBTR rates of 33% (95% CI, 0%-57%) and 2% (95% CI, 0%-6%; P<.0001), respectively. On multivariable analysis, triple-negative phenotype was the only predictor of IBTR, with borderline statistical significance after adjusting for tumor grade (P=.0537). Conclusions: Overall outcomes were excellent, particularly for patients with estrogen receptor-positive disease. Patients in this study with triple-negative breast cancer had a significantly higher IBTR rate than patients with other receptor phenotypes when treated with 3D-APBI. Larger, prospective 3D-APBI clinical trials should continue to evaluate the effect of hormone receptor phenotype on IBTR rates.

  12. A Combined Shielding Design for a Neutron Generator and a Linear Accelerator at Soreq NRC

    International Nuclear Information System (INIS)

    Epstein, L.

    2014-01-01

    A new radiography facility is designed at Soreq NRC. The facility will hold a neutron generator that produces 1.73·109 n/s with an energy of 14 MeV and a linear accelerator that accelerates electrons to an energy of 9 MeV. The two radiation sources will be installed in 2 separate laboratories that will be built in an existing building. Each laboratory will have its own machine and control room. The dose rates around the sources were calculated using the FLUKA Monte Carlo code(1,2). The annual doses were calculated in several regions around the generator and the accelerator laboratories in accordance with the occupancy in each area. The calculated annual doses were compared with the dose limits specified in the Safety at Work Regulations(3) and the IAEC Standard for Protection against Ionizing Radiation. The shielding was designed to comply with the following dose constraints: 0.3 mSv/y for members of the public and 2 mSv/y for radiation workers. Each radiation source is planned to produce radiation for a maximum of 500 hours per year. The dose rate in the direct beam of the accelerator is 30 Gy/min at 1 m from the source and it will be surrounded by a collimator with an opening of 30N-tilde horizontally and 2 mm vertically, 3 m from the radiation source. The leakage radiation dose will not be greater than 1.5 mGy/min (0.005% of the direct beam, according to the manufacturer). The leakage radiation will be produced isotropically. The neutron generator will be surrounded by a shielding made of a 10 cm iron cylinder (density 7.87 g/cm3), surrounded by 50 cm of borated polyethylene (atomic percent: H (13.8%), C (82.2%), B (4%), density: 0.92 g/cm3) and 5 cm of lead (density 11.35 g/cm3). The neutron generator shielding was not designed or required in the present shielding design but was considered in the shielding calculations

  13. Kriging accelerated by orders of magnitude: combining low-rank with FFT techniques

    KAUST Repository

    Litvinenko, Alexander; Nowak, Wolfgang

    2014-01-01

    Kriging algorithms based on FFT, the separability of certain covariance functions and low-rank representations of covariance functions have been investigated. The current study combines these ideas, and so combines the individual speedup factors of all ideas. The reduced computational complexity is O(dLlogL), where L := max ini, i = 1

  14. Kriging accelerated by orders of magnitude: combining low-rank with FFT techniques

    KAUST Repository

    Litvinenko, Alexander

    2014-05-04

    Kriging algorithms based on FFT, the separability of certain covariance functions and low-rank representations of covariance functions have been investigated. The current study combines these ideas, and so combines the individual speedup factors of all ideas. The reduced computational complexity is O(dLlogL), where L := max ini, i = 1

  15. SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

    International Nuclear Information System (INIS)

    Kobulnicky, K; Pawlak, D; Purwar, A

    2015-01-01

    Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc

  16. SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kobulnicky, K; Pawlak, D; Purwar, A [Varian Medical Systems, Inc., Palo Alto, CA (United States)

    2015-06-15

    Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc.

  17. Accelerating cancer therapy development: the importance of combination strategies and collaboration. Summary of an Institute of Medicine workshop.

    Science.gov (United States)

    LoRusso, Patricia M; Canetta, Renzo; Wagner, John A; Balogh, Erin P; Nass, Sharyl J; Boerner, Scott A; Hohneker, John

    2012-11-15

    Cancer cells contain multiple genetic changes in cell signaling pathways that drive abnormal cell survival, proliferation, invasion, and metastasis. Unfortunately, patients treated with single agents inhibiting only one of these pathways--even if showing an initial response--often develop resistance with subsequent relapse or progression of their cancer, typically via the activation of an alternative uninhibited pathway. Combination therapies offer the potential for inhibiting multiple targets and pathways simultaneously to more effectively kill cancer cells and prevent or delay the emergence of drug resistance. However, there are many unique challenges to developing combination therapies, including devising and applying appropriate preclinical tests and clinical trial designs, prioritizing which combination therapies to test, avoiding overlapping toxicity of multiple agents, and overcoming legal, cultural, and regulatory barriers that impede collaboration among multiple companies, organizations, and/or institutions. More effective strategies to efficiently develop combination cancer therapies are urgently needed. Thus, the Institute of Medicine's National Cancer Policy Forum recently convened a workshop with the goal of identifying barriers that may be impeding the development of combination investigational cancer therapies, as well as potential solutions to overcome those barriers, improve collaboration, and ultimately accelerate the development of promising combinations of investigational cancer therapies. ©2012 AACR.

  18. Efficient Homodifunctional Bimolecular Ring-Closure Method for Cyclic Polymers by Combining RAFT and Self-Accelerating Click Reaction.

    Science.gov (United States)

    Qu, Lin; Sun, Peng; Wu, Ying; Zhang, Ke; Liu, Zhengping

    2017-08-01

    An efficient metal-free homodifunctional bimolecular ring-closure method is developed for the formation of cyclic polymers by combining reversible addition-fragmentation chain transfer (RAFT) polymerization and self-accelerating click reaction. In this approach, α,ω-homodifunctional linear polymers with azide terminals are prepared by RAFT polymerization and postmodification of polymer chain end groups. By virtue of sym-dibenzo-1,5-cyclooctadiene-3,7-diyne (DBA) as small linkers, well-defined cyclic polymers are then prepared using the self-accelerating double strain-promoted azide-alkyne click (DSPAAC) reaction to ring-close the azide end-functionalized homodifunctional linear polymer precursors. Due to the self-accelerating property of DSPAAC ring-closing reaction, this novel method eliminates the requirement of equimolar amounts of telechelic polymers and small linkers in traditional bimolecular ring-closure methods. It facilitates this method to efficiently and conveniently produce varied pure cyclic polymers by employing an excess molar amount of DBA small linkers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Predicting the durability of mineral external plaster using accelerated ageing tests; Prognose der Dauerhaftigkeit mineralischer Aussenputze mit Hilfe von beschleunigten Alterungstests

    Energy Technology Data Exchange (ETDEWEB)

    Bochen, Jerzy; Nowak, Henryk A. [Schlesische Technische Universitaet, Lehrstuhl Bauprozesse, Gliwice (Poland)

    2004-08-01

    This article presents a technique for accelerated ageing tests for different plasters. Two models were developed for describing the durability. The models describe changes in selected characteristics due to frost damage and leaching. The first model is based on changes in mass, the second on changes in strength. The models consider the main characteristics that influence durability, such as strength, porosity, permeability, adhesive tensil strength and aggressive environmental influences. Both models enable the durability of external plaster to be predicted. (Abstract Copyright [2004], Wiley Periodicals, Inc.) [German] Der Beitrag stellt eine Methode fuer beschleunigte Alterungstests von verschiedenen Putzen vor. Fuer die Beschreibung der Dauerhaftigkeit wurden zwei Modelle entwickelt. Die Modelle beschreiben Veraenderungen ausgewaehlter Eigenschaften, die infolge von Frostschaeden und Auslaugung auftreten. Das erste Modell basiert auf der Veraenderung der Masse und das zweite auf der Veraenderung der Festigkeit. In den Modellen werden die wesentlichen Eigenschaften beruecksichtigt, die die Dauerhaftigkeit beeinflussen, wie z. B. Festigkeit, Porositaet, Dichtigkeit, Haftzugfestigkeit und agressive Umwelteinwirkungen. Beide Modelle ermoeglichen die Prognose der Dauerhaftigkeit von Aussenputzen. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  20. Surveying and optical tooling technologies combined to align a skewed beamline at the LAMPF accelerator

    International Nuclear Information System (INIS)

    Bauke, W.; Clark, D.A.; Trujillo, P.B.

    1985-01-01

    Optical Tooling evolved from traditional surveying, and both technologies are sometimes used interchangeably in large industrial installations, since the instruments and their specialized adapters and supports complement each other well. A unique marriage of both technologies was accomplished in a novel application at LAMPF, the Los Alamos Meson Physics Facility. LAMPF consists of a linear accelerator with multiple target systems, one of which had to be altered to accommodate a new beamline for a neutrino experiment. The new line was to be installed into a crowded beam tunnel and had to be skewed and tilted in compound angles to avoid existing equipment. In this paper we describe how Optical Tooling was used in conjunction with simple alignment and reference fixtures to set fiducials on the magnets and other mechanical components of the beamline, and how theodolites and sight levels were then adapted to align these components along the calculated skew planes. Design tolerances are compared with measured alignment results

  1. Increasing Student’s Character Values by Utilizing Combination of Team Accelerated Instruction (TAI and Numbered Heads Together (NHT

    Directory of Open Access Journals (Sweden)

    Ita Nuryana

    2016-06-01

    Full Text Available This research aims to obtain empirical evidence of the effectiveness of combining Team Accelerated Instruction (TAI and Numbered Heads Together (NHT learning strategies in teaching Investments to improve students’ discipline, creativity, diligence, and participation. Population was students who enrolled in Intermediate Financial Accounting 2 course in Economics Education Department; Economics Faculty of Universitas Negeri Semarang The sample of the research consists of 48 students. Data were collected by using observations, interviews, and documentation. The stages of the research include planning, implementation, monitoring and evaluation, analysis, and reflection. Findings show that the combination of TAI and NHT does not improve students’ learning outcomes even thought it manages to increase students’ pre-test score in learning Investments as well as their participation in classroom.

  2. Combining a gas turbine modular helium reactor and an accelerator and for near total destruction of weapons grade plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, A.M.; Lane, R.K.; Sherman, R. [General Atomics, San Diego, CA (United States)

    1995-10-01

    Fissioning surplus weapons-grade plutonium (WG-Pu) in a reactor is an effective means of rendering this stockpile non-weapons useable. In addition the enormous energy content of the plutonium is released by the fission process and can be captured to produce valuable electric power. While no fission option has been identified that can accomplish the destruction of more than about 70% of the WG-Pu without repeated reprocessing and recycling, which presents additional opportunities for diversion, the gas turbine modular helium-cooled reactor (GT-MHR), using an annular graphite core and graphite inner and outer reflectors combines the maximum plutonium destruction and highest electrical production efficiency and economics in an inherently safe system. Accelerator driven sub-critical assemblies have also been proposed for WG-Pu destruction. These systems offer almost complete WG-Pu destruction, but achieve this goal by using circulating aqueous or molten salt solutions of the fuel, with potential safety implications. By combining the GT-MHR with an accelerator-driven sub-critical MHR assembly, the best features of both systems can be merged to achieve the near total destruction of WG-Pu in an inherently safe, diversion-proof system in which the discharged fuel elements are suitable for long term high level waste storage without the need for further processing. More than 90% total plutonium destruction, and more than 99.9% Pu-239 destruction, could be achieved. The modular concept minimizes the size of each unit so that both the GT-MHR and the accelerator would be straightforward extensions of current technology.

  3. A Study on Accelerated Corrosion Test by Combined Deteriorating Action of Salt Damage and Freeze-Thaw

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang-Soon; So, Byung-Tak [Sangmyung University, Cheonan (Korea, Republic of)

    2016-01-15

    In this study, the accelerated corrosion test by combined deteriorating action of salt damage and freeze-thaw was investigated. freeze-thaw cycle is one method for corrosion testing; corrosion initiation time was measured in four types of concrete samples, i.e., two samples mixed with fly ash (FA) and blast furnace slag (BS), and the other two samples having two water/cement ratio (W/C = 0.6, 0.35) without admixture (OPC60 and OPC35). The corrosion of rebar embedded in concrete occurred most quickly at the 30th freeze-thaw cycle. Moreover, a corrosion monitoring method with a half-cell potential measurement and relative dynamic elastic modulus derived from resonant frequency measures was conducted simultaneously. The results indicated that the corrosion of rebar occurred when the relative dynamic elastic modulus was less than 60%. Therefore, dynamic elastic modulus can be used to detect corrosion of steel bar. The results of the accelerated corrosion test exhibited significant difference according to corrosion periods combined with each test condition. Consequently, the OPC60 showed the lowest corrosion resistance among the samples.

  4. A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1996-01-01

    Purpose : To get an acute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic tranmultiarc beam mode based on linear accelerator photon beam. Methods and Materials : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusion : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments. the absorbed dose has been decreased to 27 % /mm in maximum at the interval of 50% to 80% of isodose line

  5. Kriging accelerated by orders of magnitude: combining low-rank with FFT techniques

    KAUST Repository

    Litvinenko, Alexander; Nowak, Wolfgang

    2014-01-01

    Kriging algorithms based on FFT, the separability of certain covariance functions and low-rank representations of covariance functions have been investigated. The current study combines these ideas, and so combines the individual speedup factors of all ideas. For separable covariance functions, the results are exact, and non-separable covariance functions can be approximated through sums of separable components. Speedup factor is 1e+8, problem sizes 1.5e+13 and 2e+15 estimation points for Kriging and spatial design.

  6. Kriging accelerated by orders of magnitude: combining low-rank with FFT techniques

    KAUST Repository

    Litvinenko, Alexander; Nowak, Wolfgang

    2014-01-01

    Kriging algorithms based on FFT, the separability of certain covariance functions and low-rank representations of covariance functions have been investigated. The current study combines these ideas, and so combines the individual speedup factors of all ideas. The reduced computational complexity is O(dLlogL), where L := max ini, i = 1..d. For separable covariance functions, the results are exact, and non-separable covariance functions can be approximated through sums of separable components. Speedup factor is 10 8, problem sizes 15e + 12 and 2e + 15 estimation points for Kriging and spatial design.

  7. Kriging accelerated by orders of magnitude: combining low-rank with FFT techniques

    KAUST Repository

    Litvinenko, Alexander

    2014-01-08

    Kriging algorithms based on FFT, the separability of certain covariance functions and low-rank representations of covariance functions have been investigated. The current study combines these ideas, and so combines the individual speedup factors of all ideas. For separable covariance functions, the results are exact, and non-separable covariance functions can be approximated through sums of separable components. Speedup factor is 1e+8, problem sizes 1.5e+13 and 2e+15 estimation points for Kriging and spatial design.

  8. Kriging accelerated by orders of magnitude: combining low-rank with FFT techniques

    KAUST Repository

    Litvinenko, Alexander

    2014-01-06

    Kriging algorithms based on FFT, the separability of certain covariance functions and low-rank representations of covariance functions have been investigated. The current study combines these ideas, and so combines the individual speedup factors of all ideas. The reduced computational complexity is O(dLlogL), where L := max ini, i = 1..d. For separable covariance functions, the results are exact, and non-separable covariance functions can be approximated through sums of separable components. Speedup factor is 10 8, problem sizes 15e + 12 and 2e + 15 estimation points for Kriging and spatial design.

  9. Plasma filamentation and shock wave enhancement in microwave rockets by combining low-frequency microwaves with external magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2016-01-01

    A filamentary plasma is reproduced based on a fully kinetic model of electron and ion transports coupled with electromagnetic wave propagation. The discharge plasma transits from discrete to diffusive patterns at a 110-GHz breakdown, with decrease in the ambient pressure, because of the rapid electron diffusion that occurs during an increase in the propagation speed of the ionization front. A discrete plasma is obtained at low pressures when a low-frequency microwave is irradiated because the ionization process becomes more dominant than the electron diffusion, when the electrons are effectively heated by the low-frequency microwave. The propagation speed of the plasma increases with decrease in the incident microwave frequency because of the higher ionization frequency and faster plasma diffusion resulting from the increase in the energy-absorption rate. An external magnetic field is applied to the breakdown volume, which induces plasma filamentation at lower pressures because the electron diffusion is suppressed by the magnetic field. The thrust performance of a microwave rocket is improved by the magnetic fields corresponding to the electron cyclotron resonance (ECR) and its higher-harmonic heating, because slower propagation of the ionization front and larger energy-absorption rates are obtained at lower pressures. It would be advantageous if the fundamental mode of ECR heating is coupled with a lower frequency microwave instead of combining the higher-harmonic ECR heating with the higher frequency microwave. This can improve the thrust performance with smaller magnetic fields even if the propagation speed increases because of the decrease in the incident microwave frequency.

  10. Plasma filamentation and shock wave enhancement in microwave rockets by combining low-frequency microwaves with external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Masayuki, E-mail: m.takahashi@al.t.u-tokyo.ac.jp [Department of Aeronautics and Astronautics, The University of Tokyo, Bunkyo-ku 113-8656 (Japan); Ohnishi, Naofumi [Department of Aerospace Engineering, Tohoku University, Sendai 980-8579 (Japan)

    2016-08-14

    A filamentary plasma is reproduced based on a fully kinetic model of electron and ion transports coupled with electromagnetic wave propagation. The discharge plasma transits from discrete to diffusive patterns at a 110-GHz breakdown, with decrease in the ambient pressure, because of the rapid electron diffusion that occurs during an increase in the propagation speed of the ionization front. A discrete plasma is obtained at low pressures when a low-frequency microwave is irradiated because the ionization process becomes more dominant than the electron diffusion, when the electrons are effectively heated by the low-frequency microwave. The propagation speed of the plasma increases with decrease in the incident microwave frequency because of the higher ionization frequency and faster plasma diffusion resulting from the increase in the energy-absorption rate. An external magnetic field is applied to the breakdown volume, which induces plasma filamentation at lower pressures because the electron diffusion is suppressed by the magnetic field. The thrust performance of a microwave rocket is improved by the magnetic fields corresponding to the electron cyclotron resonance (ECR) and its higher-harmonic heating, because slower propagation of the ionization front and larger energy-absorption rates are obtained at lower pressures. It would be advantageous if the fundamental mode of ECR heating is coupled with a lower frequency microwave instead of combining the higher-harmonic ECR heating with the higher frequency microwave. This can improve the thrust performance with smaller magnetic fields even if the propagation speed increases because of the decrease in the incident microwave frequency.

  11. Continuous or split-course combined external and intracavitary radiotherapy of locally advanced carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Pedersen, D.; Bentzen, S.M.; Overgaard, J.

    1994-01-01

    From 1974 to 1984, 442 consecutive patients with carcinoma of the uterine cervix (FIGO IIB: 139, IIIA: 10, IIIB: 221, IVA: 72) were referred for combined intracavitary (IRT) and external radiotherapy (ERT). To improve local control and reduce late rectosigmoid morbidity the treatment strategy was changed from continuous (CRT) to split-course radiotherapy (SCRT) in 1978. Stage by stage the 5-year actuarial estimates of survival, local control, and late morbidity did not differ in relation to strategy. In the patients with tumours larger than 8 cm, the SCRT involved an increased dose in point B, a reduced dose in point A from the IRT, a lower total dose in point A, and a 34 day's prolongation of the total treatment time (TTT). The resulting 5-year actuarial local control rates were significantly lower compared with those after CRT. No difference of late severe morbidity was found except in IVA patients. In the patients with tumours between 4 and 8 cm, the SCRT involved a reduced dose in point A from the IRT, an increased total dose in point A and B, and a 50 day's prolongation of the TTT. In patients with stage IIB, the 5-year actuarial central local control rate was lower (p=0.06), and the 5-year estimate of late severe morbidity significantly higher after SCRT compared with CRT. It is concluded that the increase of the dose in point B in the SCRT was insufficient to prevent the deleterious effect on local tumour control of either the lower dose from IRT in point A, or the prolonged TTT. The increase of the total dose in the SCRT may explain why the late morbidity was not reduced, and may suggest that the TTT is of no significant importance for the risk of late normal tissue damage. (orig.)

  12. Evaluation of stone durability using a combination of ultrasound, mechanical and accelerated aging tests

    International Nuclear Information System (INIS)

    Molina, E; Cultrone, G; Sebastián, E; Alonso, F J

    2013-01-01

    The durability of a rock when exposed to decay agents is an important criterion when assessing its quality as a building material. Our study focuses on six varieties of natural stone (two limestones, one dolostone, one travertine and two sandstones) that are widely used in both new and historical buildings. In order to assess their quality, we measured and characterized their dynamic elastic properties using ultrasounds, we measured their compressive strength using the uniaxial compression test and we evaluated their durability by means of accelerated aging tests (freeze-thaw and salt crystallization). In order to get a full picture of the decay suffered by the different stones, we determined the composition and amount of the clay fraction of the six stones. We also observed small fragments subjected to the salt crystallization test under an environmental scanning electron microscope to study any textural change and measured the changes of colour on the surface with a spectrophotometer. Finally, we analysed the pore system of the stones before and after their deterioration using mercury injection porosimetry. We then compared the results for the different stones and found that dolostone obtained the best results, while the two limestones proved to be the least durable and had the lowest compressive strength. (paper)

  13. Combining computation and experiment to accelerate the discovery of new hydrogen storage materials

    Science.gov (United States)

    Siegel, Donald

    2009-03-01

    The potential of emerging technologies such as fuel cells (FCs) and photovoltaics for environmentally-benign power generation has sparked renewed interest in the development of novel materials for high density energy storage. For applications in the transportation sector, the demands placed upon energy storage media are especially stringent, as a potential replacement for fossil-fuel-powered internal combustion engines -- namely, the proton exchange membrane FC -- utilizes hydrogen as a fuel. Although hydrogen has about three times the energy density of gasoline by weight, its volumetric energy density (even at 700 bar) is roughly a factor of six smaller. Consequently, the safe and efficient storage of hydrogen has been identified as one of the key materials-based challenges to realizing a transition to FC vehicles. This talk will present an overview of recent efforts at Ford aimed at developing new materials for reversible, solid state hydrogen storage. A tight coupling between first-principles modeling and experiments has greatly accelerated our efforts, and several examples illustrating the benefits of this approach will be presented.

  14. Estimation of remote effects in blood animals after combination action of external acute gamma-radiation and EHF-range radiowave

    International Nuclear Information System (INIS)

    Chudakova, O.V.; Nikolaevich, L.N.

    2004-01-01

    In work the experimental data on study of influence combination action of external acute gamma-radiation and EMR SHF-range on hematological status of animals. It is revealed the stimulating effect of action of EMR on irradiated organism. (Authors)

  15. Combined effects of external electric and magnetic fields on electromagnetically induced transparency of a two-dimensional quantum dot

    International Nuclear Information System (INIS)

    Rezaei, Gh.; Shojaeian Kish, S.; Avazpour, A.

    2012-01-01

    In this article effects of external electric and magnetic fields on the electromagnetically induced transparency of a hydrogenic impurity confined in a two-dimensional quantum dot are investigated. To do this the probe absorption, group velocity and refractive index of the medium in the presence of external electric and magnetic fields are discussed. It is found that, electromagnetically induced transparency occurs in the system and its frequency, transparency window and group velocity of the probe field strongly depend on the external fields. In comparison with atomic system, one may control the electromagnetically induced transparency and the group velocity of light in nano structures with the dot size and confinement potential.

  16. Accelerated Detection of Viral Particles by Combining AC Electric Field Effects and Micro-Raman Spectroscopy

    Directory of Open Access Journals (Sweden)

    Matthew Robert Tomkins

    2015-01-01

    Full Text Available A detection method that combines electric field-assisted virus capture on antibody-decorated surfaces with the “fingerprinting” capabilities of micro-Raman spectroscopy is demonstrated for the case of M13 virus in water. The proof-of-principle surface mapping of model bioparticles (protein coated polystyrene spheres captured by an AC electric field between planar microelectrodes is presented with a methodology for analyzing the resulting spectra by comparing relative peak intensities. The same principle is applied to dielectrophoretically captured M13 phage particles whose presence is indirectly confirmed with micro-Raman spectroscopy using NeutrAvidin-Cy3 as a labeling molecule. It is concluded that the combination of electrokinetically driven virus sampling and micro-Raman based signal transduction provides a promising approach for time-efficient and in situ detection of viruses.

  17. Accelerated detection of viral particles by combining AC electric field effects and micro-Raman spectroscopy.

    Science.gov (United States)

    Tomkins, Matthew Robert; Liao, David Shiqi; Docoslis, Aristides

    2015-01-08

    A detection method that combines electric field-assisted virus capture on antibody-decorated surfaces with the "fingerprinting" capabilities of micro-Raman spectroscopy is demonstrated for the case of M13 virus in water. The proof-of-principle surface mapping of model bioparticles (protein coated polystyrene spheres) captured by an AC electric field between planar microelectrodes is presented with a methodology for analyzing the resulting spectra by comparing relative peak intensities. The same principle is applied to dielectrophoretically captured M13 phage particles whose presence is indirectly confirmed with micro-Raman spectroscopy using NeutrAvidin-Cy3 as a labeling molecule. It is concluded that the combination of electrokinetically driven virus sampling and micro-Raman based signal transduction provides a promising approach for time-efficient and in situ detection of viruses.

  18. Effect of combined external uniaxial stress and dc bias on the dielectric property of BaTiO3-based dielectrics in multilayer ceramic capacitor: thermodynamics and experiments

    International Nuclear Information System (INIS)

    Yang Gang; Yue Zhenxing; Sun Tieyu; Gou Huanlin; Li Longtu

    2008-01-01

    The dielectric properties of (Nb, Y)-doped BaTiO 3 in a multilayer ceramic capacitor (MLCC) under combined external uniaxial compressive stress and dc bias field were investigated at room temperature by using a modified Ginsburg-Landau-Devonshire thermodynamic theory and the dielectric measurement. It is found that although dc bias decreases the dielectric properties dominantly, the influence of the external uniaixial compressive stress should not be neglected. When applied along a direction perpendicular to the internal electrode layer in the MLCC, the external uniaixal compressive stress will strengthen the negative effect of dc bias. In contrast, the external uniaxial compressive stress along a direction parallel to the internal electrode layer in the MLCC will increase the dielectric permittivity under dc bias field, i.e. improve the ε-V response of the MLCC. Furthermore, although there is a difference between the calculated permittivity and the measured permittivity, the effects of the combined external uniaxial compressive stress and dc bias field on the dielectric permittivity described through two approaches are in good agreement

  19. Five-Year Outcomes, Cosmesis, and Toxicity With 3-Dimensional Conformal External Beam Radiation Therapy to Deliver Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Rodríguez, Núria; Sanz, Xavier; Dengra, Josefa; Foro, Palmira; Membrive, Ismael; Reig, Anna; Quera, Jaume; Fernández-Velilla, Enric; Pera, Óscar; Lio, Jackson; Lozano, Joan; Algara, Manuel

    2013-01-01

    Purpose: To report the interim results from a study comparing the efficacy, toxicity, and cosmesis of breast-conserving treatment with accelerated partial breast irradiation (APBI) or whole breast irradiation (WBI) using 3-dimensional conformal external beam radiation therapy (3D-CRT). Methods and Materials: 102 patients with early-stage breast cancer who underwent breast-conserving surgery were randomized to receive either WBI (n=51) or APBI (n=51). In the WBI arm, 48 Gy was delivered to the whole breast in daily fractions of 2 Gy, with or without additional 10 Gy to the tumor bed. In the APBI arm, patients received 37.5 Gy in 3.75 Gy per fraction delivered twice daily. Toxicity results were scored according to the Radiation Therapy Oncology Group Common Toxicity Criteria. Skin elasticity was measured using a dedicated device (Multi-Skin-Test-Center MC-750-B2, CKelectronic-GmbH). Cosmetic results were assessed by the physician and the patients as good/excellent, regular, or poor. Results: The median follow-up time was 5 years. No local recurrences were observed. No significant differences in survival rates were found. APBI reduced acute side effects and radiation doses to healthy tissues compared with WBI (P 75% of patients in the APBI arm had excellent or good cosmesis, and these outcomes appear to be stable over time. The percentage of patients with excellent/good cosmetic results was similar in both groups. Conclusions: APBI delivered by 3D-CRT to the tumor bed for a selected group of early-stage breast cancer patients produces 5-year results similar to those achieved with conventional WBI

  20. SU-E-J-181: Effect of Prostate Motion On Combined Brachytherapy and External Beam Dose Based On Daily Motion of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, V; McLaughlin, P [Providence Cancer Center, Southfield, MI (United States); University of Michigan, Ann Arbor, MI (United States); Ealbaj, J [University of Michigan, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: In this study, the adequacy of target expansions on the combined external beam and implant dose was examined based on the measured daily motion of the prostate. Methods: Thirty patients received an I–125 prostate implant prescribed to dose of 90Gy. This was followed by external beam to deliver a dose of 90Gyeq (external beam equivalent) to the prostate over 25 to 30 fractions. An ideal IMRT plan was developed by optimizing the external beam dose based on the delivered implant dose. The implant dose was converted to an equivalent external beam dose using the linear quadratic model. Patients were set up on the treatment table by daily orthogonal imaging and aligning the marker seeds in the prostate. Orthogonal images were obtained at the end of treatment to assess prostate intrafraction motion. Based on the observed motion of the markers between the initial and final images, 5 individual plans showing the actual dose delivered to the patient were calculated. A final true dose distribution was established based on summing the implant dose and the 5 external beam plans. Dose to the prostate, seminal vesicles, lymphnodes and normal tissues, rectal wall, urethra and lower sphincter were calculated and compared to ideal. On 18 patients who were sexually active, dose to the corpus cavernosum and internal pudendal artery was also calculated. Results: The average prostate motion in 3 orthogonal directions was less than 1 mm with a standard deviation of less than +2 mm. Dose and volume parameters showed that there was no decrease in dose to the targets and a marginal decrease in dose to in normal tissues. Conclusion: Dose delivered by seed implant moves with the prostate, decreasing the impact of intrafractions dose movement on actual dose delivered. Combined brachytherapy and external beam dose delivered to the prostate was not sensitive to prostate motion.

  1. Hydrogel and Platelet-Rich Plasma Combined Treatment to Accelerate Wound Healing in a Nude Mouse Model

    Directory of Open Access Journals (Sweden)

    Yu Gil Park

    2017-05-01

    Full Text Available BackgroundPlatelet-rich plasma (PRP contains high concentrations of growth factors involved in wound healing. Hydrogel is a 3-dimensional, hydrophilic, high-molecular, reticular substance generally used as a dressing formulation to accelerate wound healing, and also used as a bio-applicable scaffold or vehicle. This study aimed to investigate the effects of PRP and hydrogel on wound healing, in combination and separately, in an animal wound model.MethodsA total of 64 wounds, with 2 wounds on the back of each nude mouse, were classified into 4 groups: a control group, a hydrogel-only group, a PRP-only group, and a combined-treatment group. All mice were assessed for changes in wound size and photographed on scheduled dates. The number of blood vessels was measured in all specimens. Immunohistochemical staining was used for the analysis of vascular endothelial growth factor (VEGF expression.ResultsDifferences in the decrease and change in wound size in the combined-treatment group were more significant than those in the single-treatment groups on days 3, 5, 7, and 10. Analysis of the number of blood vessels through histological examination showed a pattern of increase over time that occurred in all groups, but the combined-treatment group exhibited the greatest increase on days 7 and 14. Immunohistochemical staining showed that VEGF expression in the combined-treatment group exhibited its highest value on day 7.ConclusionsThis experiment demonstrated improved wound healing using a PRP–hydrogel combined treatment compared to either treatment individually, resulting in a decrease in wound size and a shortening of the healing period.

  2. A unique combination of infrared and microwave radiation accelerates wound healing.

    Science.gov (United States)

    Schramm, J Mark; Warner, Dave; Hardesty, Robert A; Oberg, Kerby C

    2003-01-01

    Light or electromagnetic radiation has been reported to enhance wound healing. The use of selected spectra, including infrared and microwave, has been described; however, no studies to date have examined the potential benefit of combining these spectra. In this study, a device that emits electromagnetic radiation across both the infrared and microwave ranges was used. To test the effects of this unique electromagnetic radiation spectrum on wound healing, two clinically relevant wound-healing models (i.e., tensile strength of simple incisions and survival of McFarlane flaps) were selected. After the creation of a simple full-thickness incision (n = 35 rats) or a caudally based McFarlane flap (n = 33 rats), animals were randomly assigned to one of three treatment groups: untreated control, infrared, or combined electromagnetic radiation. Treatment was administered for 30 minutes, twice daily for 18 days in animals with simple incisions, and 15 days in animals with McFarlane flaps. The wound area or flap was harvested and analyzed, blinded to the treatment regimens. A p value of less than 0.05 obtained by analysis of variance was considered to be statistically significant. Animals receiving combined electromagnetic radiation demonstrated increased tensile strength (2.62 N/mm2) compared with animals receiving infrared radiation (2.36 N/mm2) or untreated controls (1.73 N/mm2, p radiation had increased flap survival (78.0 percent) compared with animals receiving infrared radiation (69.7 percent) and untreated controls (63.1 percent, p radiation provided a distinct advantage in wound healing that might augment current treatment regimens.

  3. Advanced concepts for acceleration

    International Nuclear Information System (INIS)

    Keefe, D.

    1986-07-01

    Selected examples of advanced accelerator concepts are reviewed. Such plasma accelerators as plasma beat wave accelerator, plasma wake field accelerator, and plasma grating accelerator are discussed particularly as examples of concepts for accelerating relativistic electrons or positrons. Also covered are the pulsed electron-beam, pulsed laser accelerator, inverse Cherenkov accelerator, inverse free-electron laser, switched radial-line accelerators, and two-beam accelerator. Advanced concepts for ion acceleration discussed include the electron ring accelerator, excitation of waves on intense electron beams, and two-wave combinations

  4. Pulsed dose rate brachytherapy as the boost in combination with external beam irradiation in base of tongue cancer. Long-term results from a uniform clinical series

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2011-03-01

    Full Text Available Purpose: To evaluate long time outcome with regard to local tumour control, side effects and quality of life of combined pulsed dose rate (PDR boost and hyperfractionated accelerated external beam radiotherapy (EBRT for primary base of tongue (BOT cancers. Material and methods: Between 1994 and 2007, the number of 83 patients were treated with primary T1-T4 BOT cancers. Seven patients (8% were T1-2N0 (AJCC stage I-II and 76 (92% patients were T1-2N+ or T3-4N0-2 (AJCC stage III-IV. The mean estimated primary tumour volume was 15.4 (1-75 cm3. EBRT was given with 1.7 Gy bid to 40.8 Gy to primary tumour and bilateral neck lymph nodes in 2.5 weeks. PDR boost of 35 Gy and a neck dissection in clinical node positive case was performed 2-3 weeks later. The patients were followed for a median of 54 (2-168 months. Results: The 2-, 5- and 10-years rates of actuarial local control were 91%, 89% and 85%, overall survival 85%, 65% and 44%, disease free survival 86%, 80% and 76%, respectively. The regional control rate was 95%. Six patients (7% developed distant metastases. A dosimetric analysis showed a mean of 100% isodose volume of 58.2 (16.7-134 cm3. In a review of late complications 11 cases of minor (13% and 5 of major soft tissue necroses (6%, as well as 6 cases of osteoradionecroses (7% were found. The patients median subjective SOMA/LENT scoring at last follow up was as follow: grade 0 for pain and trismus, grade 1 for dysphagia and taste alteration, and grade 2 for xerostomia. Global visual- analogue-scale (VAS scoring of quality of life was 8. Conclusion: Local and regional tumour control rate was excellent in this treatment protocol. The data shows the PDR boost as at least as effective as published continuous low dose rate (CLDR results.

  5. Sensitivity to psychosocial chronic stressors and adolescents' externalizing problems: Combined moderator effects of resting heart rate and parental psychiatric history.

    Science.gov (United States)

    Zandstra, Anna Roos E; Ormel, Johan; Dietrich, Andrea; van den Heuvel, Edwin R; Hoekstra, Pieter J; Hartman, Catharina A

    2018-04-01

    From the literature it is not clear whether low resting heart rate (HR) reflects low or high sensitivity to the detrimental effects of adverse environments on externalizing problems. We studied parental psychiatric history (PH), reflecting general vulnerability, as possible moderator explaining these inconsistencies. Using Linear Mixed Models, we analyzed data from 1914 subjects, obtained in three measurement waves (mean age 11, 13.5, and 16 years) from the TRacking Adolescents' Individual Lives Survey population-based cohort and the parallel clinic-referred cohort. As hypothesized, more chronic stressors predicted more externalizing problems in vulnerable individuals with high resting HR but not in those with low resting HR, suggesting high vs. low sensitivity, respectively, to adverse environmental influences. Low sensitivity to adverse environmental influences in vulnerable individuals exposed to high stressor levels was additionally confirmed by high heart rate variability (Root Mean Squared Successive Difference; RMSSD). In adolescents with low vulnerability, in contrast, the association between chronic stressors and externalizing problems did not substantially differ by resting HR and RMSSD. Future research may demonstrate whether our findings extend to other adverse, or beneficial, influences. Notwithstanding their theoretical interest, the effects were small, only pertained to parent-reported externalizing problems, refer to a small subset of respondents in our sample, and are in need of replication. We conclude that HR and RMSSD are unlikely to be strong moderators of the association between stressors and externalizing problems. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. A periodic plasma waveguide accelerator

    International Nuclear Information System (INIS)

    Cole, F.T.

    1985-01-01

    The increasing cost of synchrotrons and storage rings has given new interest in the search for new methods of acceleration. The primary goal of this search is very large accelerating fields, because the cost of an accelerator to reach TeV energies is dominated by costs that scale with length. Very large electric fields are possible in plasmas and in lasers and many geometries are being studied that make use of plasmas, lasers, or combinations of them. In a plasma accelerator, the plasma can have several different functions. It may act as a medium for the propagation of accelerating electric-field waves. In addition, these waves may also act as a source of the energy needed to accelerate particles. Accelerators using various waves in plasmas have been built and studied in many laboratories. The device proposed here is an attempt to separate the two functions of providing a medium and providing an energy source. A relatively low-energy electron beam is used as a non-neutral plasma only to make a slow-wave medium for the propagation of an externally generated wave. The wave is a TM electromagnetic wave and the device may be thought of as a conventional electron linear accelerator with the evacuated volume and metallic envelope replaced by the electron beam. A separate second beam, which may be electrons or heavier particles, is accelerated. The application in mind here is a single-pass collider

  7. Sensitivity to psychosocial chronic stressors and adolescents’ externalizing problems : Combined moderator effects of resting heart rate and parental psychiatric history

    NARCIS (Netherlands)

    Zandstra, A.R.E.; Ormel, J.; Dietrich, A.; van den Heuvel, E.R.; Hoekstra, P.J.; Hartman, C.A.

    2018-01-01

    From the literature it is not clear whether low resting heart rate (HR) reflects low or high sensitivity to the detrimental effects of adverse environments on externalizing problems. We studied parental psychiatric history (PH), reflecting general vulnerability, as possible moderator explaining

  8. Accelerated partial breast irradiation with external beam three-dimensional conformal radiotherapy. Five-year results of a prospective phase II clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Mozsa, Emoeke [National Institute of Oncology, Centre of Radiotherapy, Budapest (Hungary); Landesklinikum Wiener Neustadt, Department of Radiooncology and Radiotherapy, Wiener Neustadt (Austria); Meszaros, Norbert; Major, Tibor; Froehlich, Georgina; Stelczer, Gabor; Fodor, Janos; Polgar, Csaba [National Institute of Oncology, Centre of Radiotherapy, Budapest (Hungary); Sulyok, Zoltan [National Institute of Oncology, Centre of Surgery, Budapest (Hungary)

    2014-05-15

    The aim of this study was to report the 5-year results of accelerated partial breast irradiation (APBI) using external beam three-dimensional conformal radiotherapy (3D-CRT). Between 2006 and 2011, 44 patients with low-risk, stage I-II breast cancer underwent breast-conserving surgery. Postoperative APBI was given by means of 3D-CRT using three to five non-coplanar fields. The total dose of APBI was 36.9 Gy (nine fractions of 4.1 Gy b.i.d.). The mean follow-up time was 58.2 months for surviving patients. Survival results, side effects, and cosmetic results were assessed. One (2.3 %) local recurrence was observed, for a 5-year actuarial rate of 3.7 %. Neither regional nor distant failure was observed. Two patients died of internal disease. The 5-year disease-free, cancer-specific, and overall survival rates were 96.3, 100, and 95.1 %, respectively. Acute side effects included grade 1 (G1) erythema in 75 %, G1 parenchymal induration in 46 %, and G1 pain in 46 % of patients. No G2 or higher acute side effect occurred. Late side effects included G1, G2, and G3 fibrosis in 44, 7, and 2 % of patients, respectively, G1 skin pigmentation in 12 %, and G1 pain in 2 %. Asymptomatic fat necrosis occurred in 14 %. Cosmetic results were rated excellent or good in 86 % of cases by the patients themselves and 84 % by the physicians. The 5-year local tumor control, toxicity profile, and cosmetic results of APBI delivered with external beam 3D-CRT are encouraging and comparable to other APBI series. (orig.) [German] Evaluation der 5-Jahres-Ergebnisse bezueglich Ueberleben, Tumorkontrolle, Nebenwirkungen und Kosmetik nach Teilbrustbestrahlung (APBI) mittels 3-D-konformaler, akzelerierter Radiotherapie (3D-CRT). Zwischen 2006 und 2011 wurden 44 Patienten mit Brustkrebs im Stadium I-II und niedrigem Risikoprofil brusterhaltend operiert. Die adjuvante, 3-D-konformale APBI wurde mittels 3-5 nonkoplanarer Feldern durchgefuehrt. Die Gesamtdosis betrug 36,9 Gy bei 9 -mal 4,1 Gy b.i.d.. Nach

  9. Results of the intestitial brachytherapy and of the combination external radiation-brachytherapy in 150 patients with carcinoma of the oral tongue and floor of the mouth

    International Nuclear Information System (INIS)

    Sannazzari, G.L.; Negri, G.L.; Ozzello, F.

    1986-01-01

    The authors report their experience on the treatment of carcinoma of the oral tongue and floor of the mouth with interstitial brachytherapy, alone or in conbination with external irradiation. One hundred and fifty patients were treated; among these, 116 with brachytherapy alone, 34 with combined treatment. The five years local control in those patients treated with brachytherapy alone was 72.5% in T1, 61.2% in T2 and 35% in T3; in those patients treated with external irradiation and brachytherapy the global five years control was 42.5%. The global five years survival was 64% in the patients treated with brachytherapy alone 48% in the patients treated with combined therapy

  10. Salter-Harris type II metacarpal and metatarsal fracture in three foals. Treatment by minimally-invasive lag screw osteosynthesis combined with external coaptation.

    Science.gov (United States)

    Klopfenstein Bregger, Micaël D; Fürst, Anton E; Kircher, Patrick R; Kluge, Katharina; Kummer, Martin

    2016-05-18

    To describe minimally-invasive lag screw osteosynthesis combined with external coaptation for the treatment of Salter-Harris type II third metacarpal and third metatarsal bone fractures. Three foals aged two weeks to four months with a Salter-Harris type II third metacarpal or third metatarsal fracture. Surgery was carried out under general anaesthesia in lateral recumbency. After fracture reduction, the metaphyseal fragment was stabilized with two cortical screws placed in lag fashion under fluoroscopic control. A cast was applied for at least two weeks. All foals had a good outcome with complete fracture healing and return to complete soundness without any angular limb deformity. All foals had moderate transient digital hyperextension after cast removal. Internal fixation of Salter-Harris type II third metacarpal or third metatarsal fractures with two cortical screws in lag fashion, combined with external coaptation provided good stabilization and preserved the longitudinal growth potential of the injured physis.

  11. Results of the intestitial brachytherapy and of the combination external radiation-brachytherapy in 150 patients with carcinoma of the oral tongue and floor of the mouth

    Energy Technology Data Exchange (ETDEWEB)

    Sannazzari, G L; Negri, G L; Ozzello, F

    1986-01-01

    The authors report their experience on the treatment of carcinoma of the oral tongue and floor of the mouth with interstitial brachytherapy, alone or in conbination with external irradiation. One hundred and fifty patients were treated; among these, 116 with brachytherapy alone, 34 with combined treatment. The five years local control in those patients treated with brachytherapy alone was 72.5% in T1, 61.2% in T2 and 35% in T3; in those patients treated with external irradiation and brachytherapy the global five years control was 42.5%. The global five years survival was 64% in the patients treated with brachytherapy alone 48% in the patients treated with combined therapy. 42 refs.

  12. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis

    OpenAIRE

    Zhang, Shaobo; Zhang, Yibao; Wang, Shenghong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-01-01

    Purpose: To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. Methods: We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the ...

  13. Combined use of two supervised learning algorithms to model sea turtle behaviours from tri-axial acceleration data.

    Science.gov (United States)

    Jeantet, L; Dell'Amico, F; Forin-Wiart, M-A; Coutant, M; Bonola, M; Etienne, D; Gresser, J; Regis, S; Lecerf, N; Lefebvre, F; de Thoisy, B; Le Maho, Y; Brucker, M; Châtelain, N; Laesser, R; Crenner, F; Handrich, Y; Wilson, R; Chevallier, D

    2018-05-23

    Accelerometers are becoming ever more important sensors in animal-attached technology, providing data that allow determination of body posture and movement and thereby helping to elucidate behaviour in animals that are difficult to observe. We sought to validate the identification of sea turtle behaviours from accelerometer signals by deploying tags on the carapace of a juvenile loggerhead ( Caretta caretta ), an adult hawksbill ( Eretmochelys imbricata ) and an adult green turtle ( Chelonia mydas ) at Aquarium La Rochelle, France. We recorded tri-axial acceleration at 50 Hz for each species for a full day while two fixed cameras recorded their behaviours. We identified behaviours from the acceleration data using two different supervised learning algorithms, Random Forest and Classification And Regression Tree (CART), treating the data from the adult animals as separate from the juvenile data. We achieved a global accuracy of 81.30% for the adult hawksbill and green turtle CART model and 71.63% for the juvenile loggerhead, identifying 10 and 12 different behaviours, respectively. Equivalent figures were 86.96% for the adult hawksbill and green turtle Random Forest model and 79.49% for the juvenile loggerhead, for the same behaviours. The use of Random Forest combined with CART algorithms allowed us to understand the decision rules implicated in behaviour discrimination, and thus remove or group together some 'confused' or under--represented behaviours in order to get the most accurate models. This study is the first to validate accelerometer data to identify turtle behaviours and the approach can now be tested on other captive sea turtle species. © 2018. Published by The Company of Biologists Ltd.

  14. Can a combination of average of normals and "real time" External Quality Assurance replace Internal Quality Control?

    Science.gov (United States)

    Badrick, Tony; Graham, Peter

    2018-03-28

    Internal Quality Control and External Quality Assurance are separate but related processes that have developed independently in laboratory medicine over many years. They have different sample frequencies, statistical interpretations and immediacy. Both processes have evolved absorbing new understandings of the concept of laboratory error, sample material matrix and assay capability. However, we do not believe at the coalface that either process has led to much improvement in patient outcomes recently. It is the increasing reliability and automation of analytical platforms along with improved stability of reagents that has reduced systematic and random error, which in turn has minimised the risk of running less frequent IQC. We suggest that it is time to rethink the role of both these processes and unite them into a single approach using an Average of Normals model supported by more frequent External Quality Assurance samples. This new paradigm may lead to less confusion for laboratory staff and quicker responses to and identification of out of control situations.

  15. Immobilization in external rotation combined with abduction reduces the risk of recurrence after primary anterior shoulder dislocation.

    Science.gov (United States)

    Heidari, Kamran; Asadollahi, Shadi; Vafaee, Reza; Barfehei, Abbas; Kamalifar, Hossein; Chaboksavar, Zein Alabedin; Sabbaghi, Mohammad

    2014-06-01

    We aimed to compare the effectiveness of immobilization in abduction and external rotation vs immobilization in adduction and internal rotation after primary anterior dislocation of the shoulder. The study randomized 102 patients (age range, 15-55 years) with the diagnosis of primary anterior dislocation of the shoulder to receive immobilization in adduction and internal rotation (AdIR, n = 51) using sling and swathe bandage or immobilization in abduction and external rotation (AbER, n = 51) with a stabilizer brace. Patients received a rehabilitation program 3 weeks after the intervention. After a 24-month follow-up, 33.3% in the AdIR group and 3.9% in the AbER group had recurrence (P patients in the AbER group (19.6%) and 3 in the AdIR group (5.8%) discontinued shoulder immobilization before 3 weeks (P = .03). In patients without recurrence, the anterior apprehension test was positive in 6 of 34 in the AdIR group (17.6%) and in 4 of 49 in the AbER group (8.1%, P = .19). Immobilization with the shoulder joint in abduction and external rotation is an effective method to reduce the risk of recurrence after primary anterior shoulder dislocations and should be preferred to the traditional method of immobilization in adduction and internal rotation in clinical practice. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  16. Combined intraoperative and external irradiation of the celiac artery in the rabbit: Effects on gastric mucosal blood flow; Kombinierte intraoperative und externe Bestrahlung der Arteria coeliaca beim Kaninchen: Auswirkungen auf die Durchblutung der Magenschleimhaut

    Energy Technology Data Exchange (ETDEWEB)

    Doerr, W. [Universitaetsklinikum Carl Gustav Carus, Dresden (Germany). Klinik und Poliklinik fuer Strahlentherapie]|[GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany); Kallfass, E. [GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany); Berg, D. [GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany); Kummermehr, J. [GSF-Inst. fuer Strahlenbiologie, Oberschleissheim (Germany)

    1996-12-01

    Aim: To demonstrate changes in gastric mucosal blood flow caused by intraoperative radiotherapy of the celiac artery combined with external radiotherapy of the upper abdomen in a rabbit model. The study was designed to identify a possible correlation between a radiation-induced reduction in mucosal blood flow and the induction of gastric ulcer. Material and Method: Intraoperative radiation doses of 0 or 30 Gy were given to the celiac artery in rabbits. After a delay of 14 days external radiotherapy of the upper abdomen with 3x4 Gy/week to a maximum total dose of 40 Gy was initiated. Gastric mucosal blood flow was assessed by intraventricular injection of radioactively-labelled microspheres (15 {mu}m) followed by measurement of radioactivity in the mucosa. The injections were performed at various time intervals between 2 and 63 days after intraoperative radiation. Results: Intraoperative radiotherapy, including sham-intraoperative radiation, resulted in a transitory reduction of mucosal blood flow by about 50% of the control value on day 7. After a temporary recovery by day 14, a marked and permanent reduction in blood flow was assessed after week 6. This time corresponds to the time of development of gastric ulcer. Conclusions: A relationship between the time of ulcer development and of reduced gastric mucosal blood flow was observed after combined intraoperative and external radiotherapy. The mechanical component of intraoperative treatment has to be emphasized. Reduced blood flow was also seen after intraoperative radiotherapy alone, without an induction of ulcer by this treatment. Hence additional mucosal damage by external radiation must be present for the induction of gastric ulcer. (orig.) [Deutsch] Ziel: Untersuchung der Veraenderungen der Magenschleimhautdurchblutung am Kaninchen als Folge einer kombinierten intraoperativen Bestrahlung der Arteria coeliaca und externen Bestrahlung des Oberbauchs. Durch diesen Ansatz sollte ein moeglicher Zusammenhang

  17. Modeling the dynamics of a storm-time acceleration event: combining MHD effects with wave-particle interactions

    Science.gov (United States)

    Elkington, S. R.; Alam, S. S.; Chan, A. A.; Albert, J.; Jaynes, A. N.; Baker, D. N.; Wiltberger, M. J.

    2017-12-01

    Global simulations of radiation belt dynamics are often undertaken using either a transport formalism (e.g. Fokker-Plank), or via test particle simulations in model electric and magnetic fields. While transport formalisms offer computational efficiency and the ability to deal with a wide range of wave-particle interactions, they typically rely on simplified background fields, and often are limited to empirically-specified stochastic (diffusive) wave-particle interactions. On the other hand, test particle simulations may be carried out in global MHD simulations that include realistic physical effects such as magnetopause shadowing, convection, and substorm injections, but lack the ability to handle physics outside the MHD approximation in the realm of higher frequency (kHz) wave populations.In this work we introduce a comprehensive simulation framework combining global MHD/test particle techniques to provide realistic background fields and radial transport processes, with a Stochastic Differential Equation (SDE) method for addressing high frequency wave-particle interactions. We examine the March 17, 2013 storm-time acceleration period, an NSF-GEM focus challenge event, and use the framework to examine the relative importance of physical effects such as magnetopause shadowing, diffusive and advective transport processes, and wave-particle interactions through the various phases of the storm.

  18. Accelerated differentiation of osteoblast cells on polycaprolactone scaffolds driven by a combined effect of protein coating and plasma modification

    Energy Technology Data Exchange (ETDEWEB)

    Yildirim, Eda D; Gueceri, Selcuk; Sun, Wei [Department of Mechanical Engineering and Mechanics, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104 (United States); Besunder, Robyn; Allen, Fred [Drexel University, School of Biomedical Engineering Science and Health System, 3141 Chestnut Street, Philadelphia, PA 19104 (United States); Pappas, Daphne, E-mail: edy22@drexel.ed [Army Research Laboratory, Aberdeen Proving Ground, MD 21005 (United States)

    2010-03-15

    A combined effect of protein coating and plasma modification on the quality of the osteoblast-scaffold interaction was investigated. Three-dimensional polycaprolactone (PCL) scaffolds were manufactured by the precision extrusion deposition (PED) system. The structural, physical, chemical and biological cues were introduced to the surface through providing 3D structure, coating with adhesive protein fibronectin and modifying the surface with oxygen-based plasma. The changes in the surface properties of PCL after those modifications were examined by contact angle goniometry, surface energy calculation, surface chemistry analysis (XPS) and surface topography measurements (AFM). The effects of modification techniques on osteoblast short-term and long-term functions were examined by cell adhesion, proliferation assays and differentiation markers, namely alkaline phosphatase activity (ALP) and osteocalcin secretion. The results suggested that the physical and chemical cues introduced by plasma modification might be sufficient for improved cell adhesion, but for accelerated osteoblast differentiation the synergetic effects of structural, physical, chemical and biological cues should be introduced to the PCL surface.

  19. An external-cavity quantum cascade laser operating near 5.2 µm combined with cavity ring-down spectroscopy for multi-component chemical sensing

    Science.gov (United States)

    Dutta Banik, Gourab; Maity, Abhijit; Som, Suman; Pal, Mithun; Pradhan, Manik

    2018-04-01

    We report on the performance of a widely tunable continuous wave mode-hop-free external-cavity quantum cascade laser operating at λ ~ 5.2 µm combined with cavity ring-down spectroscopy (CRDS) technique for high-resolution molecular spectroscopy. The CRDS system has been utilized for simultaneous and molecule-specific detection of several environmentally and bio-medically important trace molecular species such as nitric oxide, nitrous oxide, carbonyl sulphide and acetylene (C2H2) at ultra-low concentrations by probing numerous rotationally resolved ro-vibrational transitions in the mid-IR spectral region within a relatively small spectral range of ~0.035 cm-1. This continuous wave external-cavity quantum cascade laser-based multi-component CRDS sensor with high sensitivity and molecular specificity promises applications in environmental sensing as well as non-invasive medical diagnosis through human breath analysis.

  20. Use of novel sensors combining local positioning and acceleration to measure feeding behavior differences associated with lameness in dairy cattle.

    Science.gov (United States)

    Barker, Z E; Vázquez Diosdado, J A; Codling, E A; Bell, N J; Hodges, H R; Croft, D P; Amory, J R

    2018-04-25

    Time constraints for dairy farmers are an important factor contributing to the under-detection of lameness, resulting in delayed or missed treatment of lame cows within many commercial dairy herds. Hence, a need exists for flexible and affordable cow-based sensor systems capable of monitoring behaviors such as time spent feeding, which may be affected by the onset of lameness. In this study a novel neck-mounted mobile sensor system that combines local positioning and activity (acceleration) was tested and validated on a commercial UK dairy farm. Position and activity data were collected over 5 consecutive days for 19 high-yield dairy cows (10 lame, 9 nonlame) that formed a subset of a larger (120 cow) management group housed in a freestall barn. A decision tree algorithm that included sensor-recorded position and accelerometer data was developed to classify a cow as doing 1 of 3 categories of behavior: (1) feeding, (2) not feeding, and (3) out of pen for milking. For each classified behavior the mean number of bouts, the mean bout duration, and the mean total duration across all bouts was determined on a daily basis, and also separately for the time periods in between milking (morning = 0630-1300 h; afternoon = 1430-2100 h; night = 2230-0500 h). A comparative analysis of the classified cow behaviors was undertaken using a Welch t-test with Benjamini-Hochberg post-hoc correction under the null hypothesis of no differences in the number or duration of behavioral bouts between the 2 test groups of lame and nonlame cows. Analysis showed that mean total daily feeding duration was significantly lower for lame cows compared with non-lame cows. Behavior was also affected by time of day with significantly lower mean total duration of feeding and higher total duration of nonfeeding in the afternoons for lame cows compared with nonlame cows. The results demonstrate how sensors that measure both position and acceleration are capable of detecting differences in feeding behavior

  1. Acceleration of vascularized bone tissue-engineered constructs in a large animal model combining intrinsic and extrinsic vascularization.

    Science.gov (United States)

    Weigand, Annika; Beier, Justus P; Hess, Andreas; Gerber, Thomas; Arkudas, Andreas; Horch, Raymund E; Boos, Anja M

    2015-05-01

    During the last decades, a range of excellent and promising strategies in Bone Tissue Engineering have been developed. However, the remaining major problem is the lack of vascularization. In this study, extrinsic and intrinsic vascularization strategies were combined for acceleration of vascularization. For optimal biomechanical stability of the defect site and simplifying future transition into clinical application, a primary stable and approved nanostructured bone substitute in clinically relevant size was used. An arteriovenous (AV) loop was microsurgically created in sheep and implanted, together with the bone substitute, in either perforated titanium chambers (intrinsic/extrinsic) for different time intervals of up to 18 weeks or isolated Teflon(®) chambers (intrinsic) for 18 weeks. Over time, magnetic resonance imaging and micro-computed tomography (CT) analyses illustrate the dense vascularization arising from the AV loop. The bone substitute was completely interspersed with newly formed tissue after 12 weeks of intrinsic/extrinsic vascularization and after 18 weeks of intrinsic/extrinsic and intrinsic vascularization. Successful matrix change from an inorganic to an organic scaffold could be demonstrated in vascularized areas with scanning electron microscopy and energy dispersive X-ray spectroscopy. Using the intrinsic vascularization method only, the degradation of the scaffold and osteoclastic activity was significantly lower after 18 weeks, compared with 12 and 18 weeks in the combined intrinsic-extrinsic model. Immunohistochemical staining revealed an increase in bone tissue formation over time, without a difference between intrinsic/extrinsic and intrinsic vascularization after 18 weeks. This study presents the combination of extrinsic and intrinsic vascularization strategies for the generation of an axially vascularized bone substitute in clinically relevant size using a large animal model. The additional extrinsic vascularization promotes tissue

  2. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40......%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these...

  3. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    %), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these......Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40...

  4. Long term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iversen, P; Rasmussen, F; Holm, H H [Depts. of Urology and Ultrasound, Herlev Hospital, Univ. of Copenhagen (Denmark)

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months. Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is bigger than 0.5 ng/ml in 8 of these. The future role of ultrasonically guided implantation in the management of prostatic cancer is discussed. (au).

  5. Acceleration of aged-landfill stabilization by combining partial nitrification and leachate recirculation: A field-scale study

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jinwook [R& D Center, Samsung Engineering Co., Ltd., 415-10 Woncheon-dong, Youngtong-gu, Suwon, Gyeonggi-do 443-823 (Korea, Republic of); Kim, Seungjin; Baek, Seungcheon [Department of Civil and Environmental Engineering, Hanyang University, Sa 3-dong, Sangnok-gu, Ansan, Gyeonggi-do 426-791 (Korea, Republic of); Lee, Nam-Hoon [Department of Environmental & Energy Engineering, Anyang University, 22 Samdeok-ro, 37 Beon-gil, Manan-gu, Anyang, Gyeonggi-do 430-714 (Korea, Republic of); Park, Seongjun; Lee, Junghun; Lee, Heechang [Department of Civil and Environmental Engineering, Hanyang University, Sa 3-dong, Sangnok-gu, Ansan, Gyeonggi-do 426-791 (Korea, Republic of); Bae, Wookeun, E-mail: wkbae@hanyang.ac.kr [Department of Civil and Environmental Engineering, Hanyang University, Sa 3-dong, Sangnok-gu, Ansan, Gyeonggi-do 426-791 (Korea, Republic of)

    2015-03-21

    Highlights: • To solve the drawbacks (NH{sub 4}{sup +} accumulation) of leachate recirculation, ex-situ SBR was applied. • Produced NO{sub 2}{sup −} was recirculated and denitrified to N{sub 2} in landfill with insufficient carbon source. • Despite the inhibition of methanogenesis by DO and nitrate, CH{sub 4} fraction eventually increased. - Abstract: Leachate recirculation for rapid landfill stabilization can result in the accumulation of high-strength ammonium. An on-site sequencing batch reactor (SBR) was therefore, applied to oxidize the ammonium to nitrite, which was then recirculated to the landfill for denitrification to nitrogen gas. At relatively higher ammonium levels, nitrite accumulated well in the SBR; the nitrite was denitrified stably in the landfill, despite an insufficient biodegradable carbon source in the leachate. As the leachate was recirculated, the methane and carbon dioxide contents produced from the landfill fluctuated, implying that the organic acids and hydrogen produced in the acid production phase acted as the carbon source for denitrification in the landfill. Leachate recirculation combined with ex-situ partial nitrification of the leachate may enhance the biodegradation process by: (a) removing the nitrogen that is contained with the leachate, and (b) accelerating landfill stabilization, because the biodegradation efficiency of landfill waste is increased by supplying sufficient moisture and its byproducts are used as the carbon source for denitrification. In addition, partial nitrification using an SBR has advantages for complete denitrification in the landfill, since the available carbon source is in short supply in aged landfills.

  6. Regional Externalities

    NARCIS (Netherlands)

    Heijman, W.J.M.

    2007-01-01

    The book offers practical and theoretical insights in regional externalities. Regional externalities are a specific subset of externalities that can be defined as externalities where space plays a dominant role. This class of externalities can be divided into three categories: (1) externalities

  7. Accelerator development

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Because the use of accelerated heavy ions would provide many opportunities for new and important studies in nuclear physics and nuclear chemistry, as well as other disciplines, both the Chemistry and Physics Divisions are supporting the development of a heavy-ion accelerator. The design of greatest current interest includes a tandem accelerator with a terminal voltage of approximately 25 MV injecting into a linear accelerator with rf superconducting resonators. This combined accelerator facility would be capable of accelerating ions of masses ranging over the entire periodic table to an energy corresponding to approximately 10 MeV/nucleon. This approach, as compared to other concepts, has the advantages of lower construction costs, lower operating power, 100 percent duty factor, and high beam quality (good energy resolution, good timing resolution, small beam size, and small beam divergence). The included sections describe the concept of the proposed heavy-ion accelerator, and the development program aiming at: (1) investigation of the individual questions concerning the superconducting accelerating resonators; (2) construction and testing of prototype accelerator systems; and (3) search for economical solutions to engineering problems. (U.S.)

  8. Intensive educational efforts combined with external quality assessment improve the preanalytical phase in general practitioner offices and nursing homes.

    Science.gov (United States)

    Sølvik, Una Ørvim; Bjelkarøy, Wenche Iren; Berg, Kari van den; Saga, Anne Lise; Hager, Helle Borgstrøm; Sandberg, Sverre

    2017-10-26

    Errors in the preanalytical phase in clinical laboratories affect patient safety. The aim of this study was to evaluate the effect of intensive educational efforts together with external quality assessment (EQA) of the preanalytical phase from 2013 to 2015 to improve patient identification in primary health care in Norway. In addition, routines for venous and capillary blood sampling were investigated. A preanalytical EQA was circulated in 2013 by the Norwegian Quality Improvement of Laboratory Examinations (Noklus) to general practitioner offices and nursing homes (n=2000) to obtain information about important issues to focus on before launching an intensive educational program with courses, posters and visits in 2013-2015. Preanalytical EQA surveys were further circulated in 2014 and 2015. The response rate varied between 42% and 55%. The percentages of participants asking for the patients' name and the Norwegian identification number increased from about 8% in 2013 to about 35% in 2015. The increase was similar for those participating in only one EQA survey and for those who participated in EQA surveys both in 2013 and 2015. Guidelines for venous and capillary blood sampling were not always followed. Educational efforts more than the preanalytical EQA influenced the actions and resulted in an increase in the percentages of participants that followed the guidelines for patient identification. Some aspects of blood sampling routines need improvement.

  9. Vp x B acceleration

    International Nuclear Information System (INIS)

    Sugihara, Ryo.

    1987-05-01

    A unique particle acceleration by an electrostatic (ES) wave, a magnetosonic shock wave as well as an electromagnetic (EM) wave is reviewed. The principle of the acceleration is that when a charged particle is carried across an external magnetic field the charge feels a DC field (the Lorentz force) and is accelerated. The theory for the ES wave acceleration is experimentally verified thought it is semi-quantitative. The shock acceleration is extensively studied theoretically and in a particle simulation method and the application is extended to phenomena in interplanetary space. The EM wave acceleration is based on a trapping in a moving neutral sheet created by the wave magnetic field and the external magnetic field, and the particle can be accelerated indefinitely. A brief sketch on a slow-wave-structure for this acceleration will be given. (author)

  10. Combining external and internal mixing representation of atmospheric aerosol for optical properties calculations: focus on absorption properties over Europe and North America using AERONET observations and AQMEII simulations

    Science.gov (United States)

    Curci, Gabriele

    2017-04-01

    The calculation of optical properties from knowledge of the composition and abundance of atmospheric aerosol implies a certain number of assumptions. First and if not known or explicitly simulated, a size distribution must be assigned to each aerosol component (e.g. sulfate-like inorganic ions, organic and back carbon, soil dust, sea salt). Second, physical-chemical properties such as the shape, density, complex refractive index, and hygroscopic factors must be associated to each aerosol species. Third, a representation of how the aerosol species combine together must be made: among those, the most popular are the assumptions of external mixing, in which each particle is assumed to be formed of a single compound and the optical properties may be calculated separately for each species, or of internal core-shell arrangement, in which each particle consists of a water-insoluble core coated with a water-soluble shell and that requires more elaborate calculations for optical properties. Previous work found that the assumption on the mixing state (external or core-shell internal) is the one that introduces the highest uncertainty, quantified in about 30% uncertainty on the calculation of monthly mean aerosol optical depth (AOD) and single-scattering albedo (SSA). The external mixing assumption is generally more reasonable for freshly emitted aerosol, while the internal mixing case is associated with aged aerosol that had the time to form the coating around the core. Both approximations are thus regarded as valid, but in general a combination of the two mixing states may be expected in a given air mass. In this work, we test a simple empirical parameterization of the fraction of internally mixed particles (F_in) in a generic air mass. The F_in fraction is calculated in two alternative ways, one exploiting the NOz to NOx ratio (proxy of the photochemical aging), and the other using the relative abundance of black carbon with respect to other aerosol components (proxy of

  11. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    Science.gov (United States)

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Labia Majora Augmentation Combined With Minimal Labia Minora Resection: A Safe and Global Approach to the External Female Genitalia.

    Science.gov (United States)

    Hersant, Barbara; Jabbour, Samer; Noel, Warren; Benadiba, Laurent; La Padula, Simone; SidAhmed-Mezi, Mounia; Meningaud, Jean Paul

    2018-04-01

    All the labia minora reduction techniques fail to treat the other component of the abnormally increased labia minora to majora ratio: the labia majora atrophy. The purpose of this study is to describe a technique of female genitalia beautification, which combines labia majora augmentation and conservative labia minora reduction. The hypertrophied labia minora were first treated by a conservative inferior wedge excision with a superior flap. The conservative excision was done to obtain labia minora that would still protrude beyond the labia majora because it will be masked by the augmentation of the labia majora. Labia majora augmentation was done by autologous fat transplantation. The newly augmented labia majora completely masked the conservatively reduced labia minora. Twenty-one patients underwent surgery for labia majora augmentation and labia minora reduction. One patient (4.7%) had a small separation of the labial edge postoperatively that resolved with no additional interventions. There was no flap necrosis or infections. No patient reported pain or sexual dysfunction. Seventeen patients (81%) were satisfied or very satisfied with their results. Labia majora augmentation combined with a conservative labia minora reduction is an appealing procedure because it enhances the global aspect of the female genitalia while reducing the labioplasty complications.

  13. Numerical simulation of the combination effect of external magnetic field and rotating workpiece on abrasive flow finishing

    Energy Technology Data Exchange (ETDEWEB)

    Kheradmand, Saeid; Esmailian, Mojtaba; Fatahy, A. [Malek-Ashtar University of Technology (MUT), Isfahan (Iran, Islamic Republic of)

    2017-04-15

    Finishing of a workpiece is a main process in the production. This affects the quality and lifetime. Finishing in order of nanometer, nowadays, is a main demand of the industries. Thus, some new finishing process, such as abrasive flow finishing, is introduced to respond this demand. This may be aided by rotating workpiece and imposing a magnetic field. Numerical simulation of this process can be beneficial to reduce the expense and predict the result in a minimum time. Accordingly, in this study, magnetorheological fluid finishing is numerically simulated. The working medium contains magnetic and abrasive particles, blended in a base fluid. Some hydrodynamic parameters and surface roughness variations are studied. It is found that combination of rotating a workpiece and imposing a magnetic field can improve the surface roughness up to 15 percent.

  14. Combination of high-dose rate brachytherapy and external beam radiotherapy for the treatment of advanced scalp angiosarcoma - case report

    International Nuclear Information System (INIS)

    Gentil, Andre Cavalcanti; Lima Junior, Carlos Genesio Bezerra; Soboll, Danyel Scheidegger; Novaes, Paulo Eduardo R.S.; Pereira, Adelino Jose; Pellizon, Antonio Carlos Assis

    2001-01-01

    The authors report a case of a patient with an extensive angiosarcoma of the scalp that was submitted only to radiotherapy with a combination of orthovoltage roentgentherapy and high-dose rate brachytherapy, using a mould. The clinical and technical features as well as the therapeutic outcome are presented, and the usefulness and peculiarities of high-dose rate brachytherapy for this particular indication is discussed. A comparative analysis of the difficulties and limitations of employing low-dose rate brachytherapy is also presented. The authors concluded that high-dose rate brachytherapy might be an useful, practical and safe option to treat neoplastic lesions of the scalp, and an alternative treatment to electrontherapy. (author)

  15. Studying the effects of combining internal and external heat recovery on techno-economic performances of gas–steam power plants

    International Nuclear Information System (INIS)

    Carapellucci, Roberto; Giordano, Lorena

    2016-01-01

    Highlights: • Effects of gas-cycle regeneration on steam–gas power plants are investigated. • Power plant performances are evaluated varying gas turbine operative parameters. • The power plant operational flexibility is assessed through an off-design analysis. • Gas-cycle regeneration improves energy and economic performance parameters. • Power increase due to regenerator by-pass depends on steam section design. - Abstract: Thermodynamic regeneration is regarded as a conventional technique to enhance the efficiency of gas turbines, by means of an internal recovery of waste heat from exhaust gases. In combined cycle power plants (CCGTs), only external heat recovery is usually applied, in order to achieve the highest steam cycle power. Combining internal and external recovery, while decreasing the power plant rated capacity, has the potential to boost the efficiency of CCGTs. This paper aims to examine the effects of thermodynamic regeneration on steam–gas power plants from the energy and economic point of view. First, a dual pressure combined cycle based on a regenerative gas turbine is designed using GateCycle software and effects on energy and economic performances are evaluated varying gas turbine operating parameters. Then, an off-design simulation of different CCGT configurations is carried out, in order to evaluate the power increase achieved by-passing the regenerator and its effects on efficiency and cost of electricity. The study has shown that the improvement of energy and economic performances of regenerative CCGTs is more and more pronounced with the increase of turbine inlet temperature (TIT). Additionally, regeneration enhances the power plant operational flexibility, allowing to obtain a 30% power increase with respect to the design value, if the regenerator is fully by-passed and the bottoming steam cycle is designed to manage the increased flue gas temperature.

  16. The multi-layered ring under parabolic distribution of radial stresses combined with uniform internal and external pressure

    Directory of Open Access Journals (Sweden)

    Christos F. Markides

    2017-04-01

    Full Text Available A recently introduced solution for the stress- and displacement-fields, developed in a multi-layered circular ring, composed of a finite number of linearly elastic concentric layers, subjected to a parabolic distribution of ra-dial stresses, is here extended to encompass a more general loading scheme, closer to actual conditions. The loading scheme includes, besides the para¬-bolic radial stresses, a combination of uniform pressures acting along the outer- and inner- most boundaries of the layered ring. The analytic solution of the problem is achieved by adopting Savin’s pioneering approach for an infinite plate with a hole strengthened by rings. Taking advantage of the results provided by the ana¬lytic solution, a numerical model, simulating the configuration of a three-layered ring (quite commonly encountered in practic¬al applications is validated. The numerical model is then used for a parametric analysis enlightening some crucial aspects of the overall response of the ring.

  17. Time-variant flexural reliability of RC beams with externally bonded CFRP under combined fatigue-corrosion actions

    International Nuclear Information System (INIS)

    Bigaud, David; Ali, Osama

    2014-01-01

    Time-variant reliability analysis of RC highway bridges strengthened with carbon fibre reinforced polymer CFRP laminates under four possible competing damage modes (concrete crushing, steel rupture after yielding, CFRP rupture and FRP plate debonding) and three degradation factors is analyzed in terms of reliability index β using FORM. The first degradation factor is chloride-attack corrosion which induces reduction in steel area and concrete cover cracking at characteristic key times (corrosion initiation, severe surface cover cracking). The second degradation factor considered is fatigue which leads to damage in concrete and steel rebar. Interaction between corrosion and fatigue crack growth in steel reinforcing bars is implemented. The third degradation phenomenon is the CFRP properties deterioration due to aging. Considering these three degradation factors, the time-dependent flexural reliability profile of a typical simple 15 m-span intermediate girder of a RC highway bridge is constructed under various traffic volumes and under different corrosion environments. The bridge design options follow AASHTO-LRFD specifications. Results of the study have shown that the reliability is very sensitive to factors governing the corrosion. Concrete damage due to fatigue slightly affects reliability profile of non-strengthened section, while service life after strengthening is strongly related to fatigue damage in concrete. - Highlights: • We propose a method to follow the time-variant reliability of strengthened RC beams. • We consider multiple competing failure modes of CFRP strengthened RC beams. • We consider combined degradation mechanisms (corrosion, fatigue, ageing of CFRP)

  18. [Early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect].

    Science.gov (United States)

    Xiao, Jian; Mao, Zhao-Guang; Zhu, Hui-Hua; Guo, Liang

    2017-03-25

    To discuss the curative effect of the early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect. From December 2013 to January 2015, 36 cases of lower limb open comminuted fractures complicated with bone defects were treated by the vancomycin ALBC combined with the external fixation support, including 26 males and 10 females with an average age of 38.0 years old ranging from 19 to 65 years old. The included cases were all open fractures of lower limbs complicated with bone defects with different degree of soft tissue injuries. Among them, 25 cases were tibial fractures, 11 cases were femoral fractures. The radiographs indicated a presence of bone defects, which ranged from 3.0 to 6.1 cm with an average of 4.0 cm. The Gustilo classification of open fractures:24 cases were type IIIA, 12 cases were typr IIIB. The percentage of wound infection, bone grafting time, fracture healing time and postoperative joint function of lower limb were observed. The function of injured limbs was evaluated at 1 month after the clinical healing of fracture based on Paley evaluation criterion. All cases were followed up for 3 to 24 months with an average of (6.0±3.0) months. The wound surface was healed well, neither bone infections nor unhealed bone defects were presented. The reoperation of bone grafting was done at 6 weeks after the patients received an early treatment with ALBC, some of them were postponed to 8 weeks till the approximate healing of fractures, the treatment course lasted for 4 to 8 months with an average of(5.5±1.5) months. According to Paley and other grading evaluations of bone and function, there were 27 cases as excellent, 5 cases as good, 3 cases as ordinary. The ALBC combined with external fixation support was an effective method for early treatment to treat the traumatic lower limb open fractures complicated with bone defects. This method

  19. Complications of combined intraoperative radiation (IORT) and external radiation (ERT) of the upper abdomen: an experimental model

    International Nuclear Information System (INIS)

    Schultz-Hector, S.; Brechenmacher, P.; Doerr, W.; Grab, J.; Kallfass, E.; Krimmel, K.; Kummermehr, J.; Sund, M.; Wilkowski, R.; Willich, N.; Zaspel, J.; Kraemling, H.-J.

    1996-01-01

    An experimental model in the rabbit is presented which is suitable for analysis of clinically relevant, early side-effects of combined upper abdominal IORT and ERT. Fractionated ERT alone given through an upper abdominal a.-p. field including the entire stomach caused gastric ulcerations within ≤ 58 days. Latent times decreased with increasing dose and the ED 50 for occurrence of ulcers was 39 ± 3.3 Gy. Single doses of IORT of 20-40 Gy alone administered through a 2-cm diameter field localized on the coeliac axis and carefully excluding any intestinal mucosa caused neither gastric ulcerations nor other clinical symptoms. When ERT with 40 Gy was preceded by IORT with 20-40 Gy or by sham IORT, 13 out of 15 animals developed ulcers after latent times which in a life-table analysis were shown to be significantly shorter than after ERT alone. However, a statistically significant IORT dose-dependence of latent time or incidence of ulcers could not be demonstrated in the present experiment. The most significant histological changes were observed in the areas of gastric ulcers. Already during ERT, the mucosal epithelium was depleted and regenerative activity was evident in spite of ongoing fractionated irradiation. However, profound irregularities in glandular structure and distribution, as well as number of proliferating epithelial cells were still present in healed ulcers at 80 days. In summary, IORT to the coeliac artery did precipitate the development of gastric ulcers induced by subsequent ERT. On the one hand, the data indicate that the surgical procedure of IORT did contribute to this effect. On the other hand, IORT to the coeliac artery could cause transient, functional alterations in blood supply to the depending organs, i.e. the stomach, and could thus precipitate the development of radiation-induced ulcers

  20. Is product diversification the Ultimate Quid Pro Quo for Gender sensitive Poverty Alleviation? Adverse Social Externalities from Combined Microfinance in Latin America and the Caribbean

    Directory of Open Access Journals (Sweden)

    ROSSEL-CAMBIER, Koen

    2013-11-01

    Full Text Available Documented deficiencies in traditional social transfer mechanisms have led to the emergence of alternative methods for reducing poverty. In many countries, microfinance institutions (MFIs have become popular instruments for redistributive propoor policies. However, they are also criticised for not being inclusive enough. This paper explores if product diversification has an effect on poverty outreach, in particular when combining micro- credit with savings and insurance. It applies cross-sectional analysis of 250 microfinance schemes in Latin America and the Caribbean. By focusing on elements of the depth of poverty outreach, the research highlights a number of possible effects of combined microfinance (CMF. Product diversification can significantly contribute to increased social outreach («breadth» of poverty outreach. However, the findings suggest that, in the case of combining credit with savings, this is leading to a relatively lower participation of poor and female clients («depth» of poverty outreach. Exclusionary and discriminatory vulnerabilities and dynamics, linked to specific financial products, may apply double or even reinforce each other. Cumulative financial, cultural, geographical or communication barriers can make participation in multiple financial products more challenging. These findings have not been adequately tackled by academic literature, but are most relevant for MFI stakeholders and policy makers. If gender-sensitive or pro-poor income generation is at the heart of the mission of MFIs, corrective measures to these forms of adverse externalities should be considered.

  1. Combination of External Beam Radiotherapy (EBRT) With Intratumoral Injection of Dendritic Cells as Neo-Adjuvant Treatment of High-Risk Soft Tissue Sarcoma Patients

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, Steven E., E-mail: steven.finkelstein@moffitt.org [H. Lee Moffitt Cancer Center, Tampa, FL (United States); Iclozan, Cristina; Bui, Marilyn M.; Cotter, Matthew J.; Ramakrishnan, Rupal; Ahmed, Jamil; Noyes, David R.; Cheong, David; Gonzalez, Ricardo J.; Heysek, Randy V.; Berman, Claudia; Lenox, Brianna C.; Janssen, William; Zager, Jonathan S.; Sondak, Vernon K.; Letson, G. Douglas; Antonia, Scott J. [H. Lee Moffitt Cancer Center, Tampa, FL (United States); Gabrilovich, Dmitry I., E-mail: dmitry.gabrilovich@moffitt.org [H. Lee Moffitt Cancer Center, Tampa, FL (United States)

    2012-02-01

    Purpose: The goal of this study was to determine the effect of combination of intratumoral administration of dendritic cells (DC) and fractionated external beam radiation (EBRT) on tumor-specific immune responses in patients with soft-tissue sarcoma (STS). Methods and Material: Seventeen patients with large (>5 cm) high-grade STS were enrolled in the study. They were treated in the neoadjuvant setting with 5,040 cGy of EBRT, split into 28 fractions and delivered 5 days per week, combined with intratumoral injection of 10{sup 7} DCs followed by complete resection. DCs were injected on the second, third, and fourth Friday of the treatment cycle. Clinical evaluation and immunological assessments were performed. Results: The treatment was well tolerated. No patient had tumor-specific immune responses before combined EBRT/DC therapy; 9 patients (52.9%) developed tumor-specific immune responses, which lasted from 11 to 42 weeks. Twelve of 17 patients (70.6%) were progression free after 1 year. Treatment caused a dramatic accumulation of T cells in the tumor. The presence of CD4{sup +} T cells in the tumor positively correlated with tumor-specific immune responses that developed following combined therapy. Accumulation of myeloid-derived suppressor cells but not regulatory T cells negatively correlated with the development of tumor-specific immune responses. Experiments with {sup 111}In labeled DCs demonstrated that these antigen presenting cells need at least 48 h to start migrating from tumor site. Conclusions: Combination of intratumoral DC administration with EBRT was safe and resulted in induction of antitumor immune responses. This suggests that this therapy is promising and needs further testing in clinical trials design to assess clinical efficacy.

  2. Treatment of localized prostate cancer using a combination of high dose rate lridium-192 brachytherapy and external beam irradiation: Initial Australian experience

    International Nuclear Information System (INIS)

    Stevens, M.J.; Stricker, P.D.; Brenner, P.C.; Kooner, R.; O'Neil, G.F.A.; Duval, P.J.; Jagavkar, R.S.; Cross, P.; Saalfeld, J.; Martland, J.

    2003-01-01

    Combination high dose rate brachytherapy (HDRB) and external beam radiation therapy is technically and clinically feasible as definitive treatment for localized prostate cancer. We report the first large Australian experience using this technique of radiation dose escalation in 82 patients with intermediate- and high-risk disease. With a median follow up of 3 years (156 weeks), complications were low and overall prostate-specific antigen progression-free survival was 91% using the American Society for Therapeutic Radiology and Oncology consensus definition. The delivery of hypofractionated radiation through the HDRB component shortens overall treatment time and is both biologically and logistically advantageous. As a radiation boost strategy, HDRB is easy to learn and could be introduced into most facilities with brachytherapy capability. Copyright (2003) Blackwell Science Pty Ltd

  3. Technique of stepwise intracranial decompression combined with external ventricular drainage catheters improve the prognosis of acute post-traumatic hemispheric brain swelling patients

    Directory of Open Access Journals (Sweden)

    Lei eShi

    2015-09-01

    Full Text Available Background: Acute post-traumatic cerebral hemispheric brain swelling (ACHS is a serious disorder that occurs after traumatic brain injury (TBI, and it often requires immediate treatment. The aim of our clinical study was to assess the effects of stepwise intracranial decompression combined with external ventricular drainage catheters on the prognosis of ACHS patients.Methods: A retrospective study was performed on 172 cases of severe craniocerebral trauma patients with acute cerebral hemispheric swelling. The patients were divided into two groups: unilateral stepwise standard large trauma craniectomy (S-SLTC combined with external ventricular drainage (EVD catheter implants (n = 86 and unilateral routine frontal temporal parietal SLTC (control group, n = 86.Result: No significant differences in age, sex, or preoperative Glasgow Coma Scale score were observed between groups (P < 0.05. There were no significant differences in the ipsilateral subdural effusion incidence rates between the S-SLTC+EVD treatment group and the routine SLTC group. However, the incidence rates of intraoperative acute encephalocele and contralateral epidural and subdural hematoma in the S-SLTC+EVD group were significantly lower than those in the SLTC group (17.4% and 3.5% vs. 37.2% and 23.3%, respectively. The mean intracranial pressure (ICP values of patients in the S-SLTC+EVD group were also lower than those in the SLTC group at days 1 through7 (P<0.05. A positive neurological outcome (GOS score 4 to 5, 50.0% and decreased mortality (15.1% was observed in the S-SLTC+EVD group compared to the neurological outcome (GOS score 4 to 5, 33.8%; 36.0% in the SLTC group (P<0.05.Conclusions: Our data suggest that S-SLTC+EVD is more effective for controlling ICP, improving neurological outcome, and decreasing mortality rate compared with routine SLTC.

  4. Polyethylene glycol hydrogel rectal spacer implantation in patients with prostate cancer undergoing combination high-dose-rate brachytherapy and external beam radiotherapy.

    Science.gov (United States)

    Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth

    2016-01-01

    To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  5. Pretreatment Endorectal Coil Magnetic Resonance Imaging Findings Predict Biochemical Tumor Control in Prostate Cancer Patients Treated With Combination Brachytherapy and External-Beam Radiotherapy

    International Nuclear Information System (INIS)

    Riaz, Nadeem; Afaq, Asim; Akin, Oguz; Pei Xin; Kollmeier, Marisa A.; Cox, Brett; Hricak, Hedvig; Zelefsky, Michael J.

    2012-01-01

    Purpose: To investigate the utility of endorectal coil magenetic resonance imaging (eMRI) in predicting biochemical relapse in prostate cancer patients treated with combination brachytherapy and external-beam radiotherapy. Methods and Materials: Between 2000 and 2008, 279 men with intermediate- or high-risk prostate cancer underwent eMRI of their prostate before receiving brachytherapy and supplemental intensity-modulated radiotherapy. Endorectal coil MRI was performed before treatment and retrospectively reviewed by two radiologists experienced in genitourinary MRI. Image-based variables, including tumor diameter, location, number of sextants involved, and the presence of extracapsular extension (ECE), were incorporated with other established clinical variables to predict biochemical control outcomes. The median follow-up was 49 months (range, 1–13 years). Results: The 5-year biochemical relapse-free survival for the cohort was 92%. Clinical findings predicting recurrence on univariate analysis included Gleason score (hazard ratio [HR] 3.6, p = 0.001), PSA (HR 1.04, p = 0.005), and National Comprehensive Cancer Network risk group (HR 4.1, p = 0.002). Clinical T stage and the use of androgen deprivation therapy were not correlated with biochemical failure. Imaging findings on univariate analysis associated with relapse included ECE on MRI (HR 3.79, p = 0.003), tumor size (HR 2.58, p = 0.04), and T stage (HR 1.71, p = 0.004). On multivariate analysis incorporating both clinical and imaging findings, only ECE on MRI and Gleason score were independent predictors of recurrence. Conclusions: Pretreatment eMRI findings predict for biochemical recurrence in intermediate- and high-risk prostate cancer patients treated with combination brachytherapy and external-beam radiotherapy. Gleason score and the presence of ECE on MRI were the only significant predictors of biochemical relapse in this group of patients.

  6. A meta-analysis of hyperfractionated and accelerated radiotherapy and combined chemotherapy and radiotherapy regimens in unresected locally advanced squamous cell carcinoma of the head and neck

    Directory of Open Access Journals (Sweden)

    Budach V

    2006-01-01

    Full Text Available Abstract Background Former meta-analyses have shown a survival benefit for the addition of chemotherapy (CHX to radiotherapy (RT and to some extent also for the use of hyperfractionated radiation therapy (HFRT and accelerated radiation therapy (AFRT in locally advanced squamous cell carcinoma (SCC of the head and neck. However, the publication of new studies and the fact that many older studies that were included in these former meta-analyses used obsolete radiation doses, CHX schedules or study designs prompted us to carry out a new analysis using strict inclusion criteria. Methods Randomised trials testing curatively intended RT (≥60 Gy in >4 weeks/>50 Gy in Results Thirty-two trials with a total of 10 225 patients were included into the meta-analysis. An overall survival benefit of 12.0 months was observed for the addition of simultaneous CHX to either CFRT or HFRT/AFRT (p Conclusion RT combined with simultaneous 5-FU, cisplatin, carboplatin, and mitomycin C as single drug or combinations of 5-FU with one of the other drugs results in a large survival advantage irrespective the employed radiation schedule. If radiation therapy is used as single modality, hyperfractionation leads to a significant improvement of overall survival. Accelerated radiation therapy alone, especially when given as split course radiation schedule or extremely accelerated treatments with decreased total dose, does not increase overall survival.

  7. Combined modality therapy for localized prostate carcinoma using Iridium-192 brachytherapy and external beam radiotherapy: results, morbidity, and the lack of value of surgical lymph node staging

    International Nuclear Information System (INIS)

    Baird, Michael; Ordorica, Edward; Dawson, Anne

    1997-01-01

    Purpose/Objective: (1) To quantitate the morbidity and 5 and 10 year bNED survival of Ir-192 temporary implant combined with external beam radiotherapy in the treatment of clinically localized Prostate Carcinoma. (2) To determine the need for nodal staging prior to implant. Materials and Methods: 335 consecutively treated patients seen between 8/17/84 and 8/13/93 were analyzed. All patents had retropertoneal nodal dissection and were implanted with Ir-192 using the Syed-Neblett template. Thirteen percent who completed treatment per protocol were found to have microscopically involved nodes on permanent section. 277 patients had completed the entire treatment protocol and had at least 2 years follow-up with DRE and serial serum PSAs. All patients were evaluated for morbidity using the standard RTOG morbidity scales. The bNED survival was determined using Kaplan-Meier methods with a non-rising PSA value of < 1.0 used as an indicator of disease control. All patients received 30 Gy in 50 hrs. to the implant volume, followed in two weeks by 34.2 Gy external beam (19 fx/ 25 days). The median follow up for the group is 55 months. Results: Morbidity: 69.2% of the patients experienced no reportable morbidity. Urinary morbidity was usually transient and mild (Grade 1 or 2 in 9.7%). 4.9 % experienced grade 3 urinary complaints (6.6% stress incontinence) and the incidence of grade 4 urinary complaints was 0.6%. Urinary complications were 2.5 times more common in patients who had previously undergone a TURP. Rectal complications were mild or moderate in 10.5% and usually consisted of asymptomatic rectal bleeding (6.9%). Severe rectal ulcer requiring temporary colostomy occurred in 1.4% and always healed after colostomy. Other morbidity consisted of mild, self-limited edema (2.1%). One patient had persistent edema post treatment, and there was one death from a CVA perioperatively (0.3%). 75% of patients who were potent prior to treatment maintained useful sexual function post

  8. Treatment Results of PDR Brachytherapy Combined With External Beam Radiotherapy in 106 Patients With Intermediate- to High-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Pieters, Bradley R.; Geijsen, Elisabeth D.; Koedooder, Kees; Blank, Leo E.C.M.; Rezaie, Elisa; Grient, Johan N.B. van der; Reijke, Theo M. de; Koning, Caro C.E.

    2011-01-01

    Purpose: To evaluate treatment outcome of pulsed dose-rate brachytherapy (PDR) combined with external-beam radiotherapy (EBRT) for the treatment of prostate cancer. Methods and Materials: Between 2002 and 2007, 106 patients were treated by EBRT combined with PDR and followed prospectively. Two, 38, and 66 patients were classified as low-, intermediate-, and high-risk disease respectively according to the National Comprehensive Cancer Network criteria. EBRT dose was 46 Gy in 2.0-Gy fractions. PDR dose was increased stepwise from 24.96 to 28.80 Gy. Biochemical disease free survival and overall survival were determined by the Kaplan-Meier method. Cumulative incidence of late gastrointestinal (GI) and genitourinary (GU) toxicity were scored, according to the Common Terminology Criteria for Adverse Events. Results: The 3- and 5-year biochemical nonevidence of disease (bNED) were 92.8% (95% confidence interval [CI], 87.1-98.5) and 89.5% (95% CI, 85.2-93.8), respectively. Overall survival at 3 and 5 years was 99% (95% CI, 96-100) and 96% (95% CI, 90-100), respectively. The 3- and 5-year Grade 2 GI toxicity was 5.3% (95% CI, 0-10.6) and 12.0% (95% CI, 1.4-22.6), respectively. No Grade 3 or higher GI toxicity was observed. The 3- and 5-year Grade 2 or higher GU toxicity was 18.7% (95% CI, 10.3-27.1) and 26.9% (95% CI, 15.1-38.7), respectively. Conclusion: Results on tumor control and late toxicity of EBRT combined with PDR are good and comparable to results obtained with EBRT combined with high-dose-rate brachytherapy for the treatment of prostate cancer.

  9. ASTOR, concept of a combined acceleration and storage ring for the production of intense pulsed or continuous beams of neutrinos, pions, muons, kaons and neutrons

    International Nuclear Information System (INIS)

    Joho, W.

    1983-01-01

    A new concept for a high intensity accelerator for 2 GeV protons using the continuous 590 MeV beam from the present ring cyclotron has been worked out at SIN. To suppress the cosmic background in neutrino experiments a pulsed beam with high peak current and low duty cycle is required. Using the so called phase expansion effect 1,2 one can combine the acceleration and storage effect in a single isochronous cyclotron ASTOR. With the help of several RF cavities, positioned at different radii, it is possible to operate ASTOR either in a pulsed mode at 1500 Hz or in a continuous mode. The anticipated beam powers are .8 MW and 4 MW respectively. The ASTOR concept is also applicable in a possible kaon factory design, acting as an interface between the SIN ring cyclotron and a 50 Hz synchrotron for 15 to 20 GeV protons

  10. Development and application of performance and cost models for the externally-fired combined cycle. Task 1, Volume 2. Topical report, June 1995

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, P.; Frey, H. [North Carolina State Univ., Raleigh, NC (United States); Rubin, E.S. [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    1995-07-01

    Increasing restrictions on emission of pollutants from conventional pulverized coal fired steam (PCFS) plant generating electrical power is raising capital and operating cost of these plants and at the same time lowering plant efficiency. This is creating a need for alternative technologies which result in lower emissions of regulated pollutants and which are thermally more efficient. Natural gas-fired combined cycle power generation systems have lower capital cost and higher efficiencies than conventional coal fired steam plants, and at this time they are the leading contender for new power plant construction in the U.S. But the intermediate and long term cost of these fuels is high and there is uncertainty regarding their long-term price and availability. Coal is a relatively low cost fuel which will be abundantly available in the long term. This has motivated the development of advanced technologies for power production from coal which will have advantages of other fuels. The Externally Fired Combined Cycle (EFCC) is one such technology. Air pollution control/hot gas cleanup issues associated with this technology are described.

  11. Acceleration of the charged particles due to chaotic scattering in the combined black hole gravitational field and asymptotically uniform magnetic field

    International Nuclear Information System (INIS)

    Stuchlik, Zdenek; Kolos, Martin

    2016-01-01

    To test the role of large-scale magnetic fields in accretion processes, we study the dynamics of the charged test particles in the vicinity of a black hole immersed into an asymptotically uniform magnetic field. Using the Hamiltonian formalism of the charged particle dynamics, we examine chaotic scattering in the effective potential related to the black hole gravitational field combined with the uniform magnetic field. Energy interchange between the translational and oscillatory modes of the charged particle dynamics provides a mechanism for charged particle acceleration along the magnetic field lines. This energy transmutation is an attribute of the chaotic charged particle dynamics in the combined gravitational and magnetic fields only, the black hole rotation is not necessary for such charged particle acceleration. The chaotic scatter can cause a transition to the motion along the magnetic field lines with small radius of the Larmor motion or vanishing Larmor radius, when the speed of the particle translational motion is largest and it can be ultra-relativistic. We discuss the consequences of the model of ionization of test particles forming a neutral accretion disc, or heavy ions following off-equatorial circular orbits, and we explore the fate of heavy charged test particles after ionization where no kick of heavy ions is assumed and only the switch-on effect of the magnetic field is relevant. We demonstrate that acceleration and escape of the ionized particles can be efficient along the Kerr black hole symmetry axis parallel to the magnetic field lines. We show that a strong acceleration of the ionized particles to ultra-relativistic velocities is preferred in the direction close to the magnetic field lines. Therefore, the process of ionization of Keplerian discs around the Kerr black holes can serve as a model of relativistic jets. (orig.)

  12. Acceleration of the charged particles due to chaotic scattering in the combined black hole gravitational field and asymptotically uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stuchlik, Zdenek; Kolos, Martin [Silesian University in Opava, Faculty of Philosophy and Science, Institute of Physics and Research Centre of Theoretical Physics and Astrophysics, Opava (Czech Republic)

    2016-01-15

    To test the role of large-scale magnetic fields in accretion processes, we study the dynamics of the charged test particles in the vicinity of a black hole immersed into an asymptotically uniform magnetic field. Using the Hamiltonian formalism of the charged particle dynamics, we examine chaotic scattering in the effective potential related to the black hole gravitational field combined with the uniform magnetic field. Energy interchange between the translational and oscillatory modes of the charged particle dynamics provides a mechanism for charged particle acceleration along the magnetic field lines. This energy transmutation is an attribute of the chaotic charged particle dynamics in the combined gravitational and magnetic fields only, the black hole rotation is not necessary for such charged particle acceleration. The chaotic scatter can cause a transition to the motion along the magnetic field lines with small radius of the Larmor motion or vanishing Larmor radius, when the speed of the particle translational motion is largest and it can be ultra-relativistic. We discuss the consequences of the model of ionization of test particles forming a neutral accretion disc, or heavy ions following off-equatorial circular orbits, and we explore the fate of heavy charged test particles after ionization where no kick of heavy ions is assumed and only the switch-on effect of the magnetic field is relevant. We demonstrate that acceleration and escape of the ionized particles can be efficient along the Kerr black hole symmetry axis parallel to the magnetic field lines. We show that a strong acceleration of the ionized particles to ultra-relativistic velocities is preferred in the direction close to the magnetic field lines. Therefore, the process of ionization of Keplerian discs around the Kerr black holes can serve as a model of relativistic jets. (orig.)

  13. Accelerating the energy policy turnaround with combined heat and power units; Mit Blockheizkraftwerken die Energiewende rund machen

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Joerg; Geiler, Nikolaus [Klimabuendnis Freiburg, Freiburg im Breisgau (Germany)

    2013-03-15

    No other type of decentralized power plants transforms natural gas to electric power so efficiently as a combined heat and power unit. In the long term, the climate-friendly effect using renewable hydrogen or renewably generated 'natural gas' even could be increased. Thus, combined heat and power units are ideal to achieve the national climate change objectives. Despite their advantages, the implementation of combined heat and power units advances only sluggishly.

  14. Neutron interrogation of actinides with a 17 MeV electron accelerator and first results from photon and neutron interrogation non-simultaneous measurements combination

    Energy Technology Data Exchange (ETDEWEB)

    Sari, A., E-mail: adrien.sari@cea.fr [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Carrel, F.; Lainé, F. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Lyoussi, A. [CEA, DEN, 13108 Saint-Paul-Lez-Durance Cedex (France)

    2013-10-01

    In this article, we demonstrate the feasibility of neutron interrogation using the conversion target of a 17 MeV linear electron accelerator as a neutron generator. Signals from prompt neutrons, delayed neutrons, and delayed gamma-rays, emitted by both uranium and plutonium samples were analyzed. First results from photon and neutron interrogation non-simultaneous measurements combination are also reported in this paper. Feasibility of this technique is shown in the frame of the measurement of uranium enrichment. The latter was carried out by combining detection of prompt neutrons from thermal fission and delayed neutrons from photofission, and by combining delayed gamma-rays from thermal fission and delayed gamma-rays from photofission.

  15. The feasibility and safety of high-intensity focused ultrasound combined with low-dose external beam radiotherapy as supplemental therapy for advanced prostate cancer following hormonal therapy.

    Science.gov (United States)

    Wu, Rui-Yi; Wang, Guo-Min; Xu, Lei; Zhang, Bo-Heng; Xu, Ye-Qing; Zeng, Zhao-Chong; Chen, Bing

    2011-05-01

    The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced prostate cancer (PCa) following hormonal therapy (HT). Our definition of HIFU+LRT refers to treating primary tumour lesions with HIFU in place of reduced field boost irradiation to the prostate, while retaining four-field box irradiation to the pelvis in conventional-dose external beam radiotherapy (CRT). We performed a prospective, controlled and non-randomized study on 120 patients with advanced PCa after HT who received HIFU, CRT, HIFU+LRT and HT alone, respectively. CT/MR imaging showed the primary tumours and pelvic lymph node metastases visibly shrank or even disappeared after HIFU+LRT treatment. There were significant differences among four groups with regard to overall survival (OS) and disease-specific survival (DSS) curves (P = 0.018 and 0.015). Further comparison between each pair of groups suggested that the long-term DSS of the HIFU+LRT group was higher than those of the other three groups, but there was no significant difference between the HIFU+LRT group and the CRT group. Multivariable Cox's proportional hazard model showed that both HIFU+LRT and CRT were independently associated with DSS (P = 0.001 and 0.035) and had protective effects with regard to the risk of death. Compared with CRT, HIFU+LRT significantly decreased incidences of radiation-related late gastrointestinal (GI) and genitourinary (GU) toxicity grade ≥ II. In conclusion, long-term survival of patients with advanced PCa benefited from strengthening local control of primary tumour and regional lymph node metastases after HT. As an alternative to CRT, HIFU+LRT showed good efficacy and better safety.

  16. Improved outcome of 131I-mIBG treatment through combination with external beam radiotherapy in the SK-N-SH mouse model of neuroblastoma.

    Science.gov (United States)

    Corroyer-Dulmont, Aurélien; Falzone, Nadia; Kersemans, Veerle; Thompson, James; Allen, Danny P; Able, Sarah; Kartsonaki, Christiana; Malcolm, Javian; Kinchesh, Paul; Hill, Mark A; Vojnovic, Boris; Smart, Sean C; Gaze, Mark N; Vallis, Katherine A

    2017-09-01

    To assess the efficacy of different schedules for combining external beam radiotherapy (EBRT) with molecular radiotherapy (MRT) using 131 I-mIBG in the management of neuroblastoma. BALB/c nu/nu mice bearing SK-N-SH neuroblastoma xenografts were assigned to five treatment groups: 131 I-mIBG 24h after EBRT, EBRT 6days after 131 I-mIBG, EBRT alone, 131 I-mIBG alone and control (untreated). A total of 56 mice were assigned to 3 studies. Study 1: Vessel permeability was evaluated using dynamic contrast-enhanced (DCE)-MRI (n=3). Study 2: Tumour uptake of 131 I-mIBG in excised lesions was evaluated by γ-counting and autoradiography (n=28). Study 3: Tumour volume was assessed by longitudinal MR imaging and survival was analysed (n=25). Tumour dosimetry was performed using Monte Carlo simulations of absorbed fractions with the radiation transport code PENELOPE. Given alone, both 131 I-mIBG and EBRT resulted in a seven-day delay in tumour regrowth. Following EBRT, vessel permeability was evaluated by DCE-MRI and showed an increase at 24h post irradiation that correlated with an increase in 131 I-mIBG tumour uptake, absorbed dose and overall survival in the case of combined treatment. Similarly, EBRT administered seven days after MRT to coincide with tumour regrowth, significantly decreased the tumour volume and increased overall survival. This study demonstrates that combining EBRT and MRT has an enhanced therapeutic effect and emphasizes the importance of treatment scheduling according to pathophysiological criteria such as tumour vessel permeability and tumour growth kinetics. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Combined administration of oseltamivir and hochu-ekki-to (TJ-41) dramatically decreases the viral load in lungs of senescence-accelerated mice during influenza virus infection.

    Science.gov (United States)

    Ohgitani, Eriko; Kita, Masakazu; Mazda, Osam; Imanishi, Jiro

    2014-02-01

    To enhance the effect of anti-influenza-virus agent treatment, the effect of combined administration of oseltamivir phosphate and hochu-ekki-to (Japanese traditional herbal medicine, HET) on early viral clearance was examined. Senescence-accelerated mice were given HET in drinking water for 2 weeks, followed by intranasal infection with influenza A virus strain PR8. After 4 hours of infection, oseltamivir was administered orally for 5 days. The viral loads in the lungs of the group receiving combined treatment were dramatically lower when compared with the viral loads in the lungs of the group receiving oseltamivir alone. HET significantly increased the induction of IL-1β and TNF-α in the lungs of PR8-infected mice and stimulated alveolar macrophage phagocytosis. From these results, we conclude that these functions may be responsible the increased effect on viral load reduction. Here, we show that the combined administration of oseltamivir and HET is very useful for influenza treatment in senescence-accelerated mice.

  18. Combined small-molecule inhibition accelerates the derivation of functional, early-born, cortical neurons from human pluripotent stem cells

    Science.gov (United States)

    Qi, Yuchen; Zhang, Xin-Jun; Renier, Nicolas; Wu, Zhuhao; Atkin, Talia; Sun, Ziyi; Ozair, M. Zeeshan; Tchieu, Jason; Zimmer, Bastian; Fattahi, Faranak; Ganat, Yosif; Azevedo, Ricardo; Zeltner, Nadja; Brivanlou, Ali H.; Karayiorgou, Maria; Gogos, Joseph; Tomishima, Mark; Tessier-Lavigne, Marc; Shi, Song-Hai; Studer, Lorenz

    2017-01-01

    Considerable progress has been made in converting human pluripotent stem cells (hPSCs) into functional neurons. However, the protracted timing of human neuron specification and functional maturation remains a key challenge that hampers the routine application of hPSC-derived lineages in disease modeling and regenerative medicine. Using a combinatorial small-molecule screen, we previously identified conditions for the rapid differentiation of hPSCs into peripheral sensory neurons. Here we generalize the approach to central nervous system (CNS) fates by developing a small-molecule approach for accelerated induction of early-born cortical neurons. Combinatorial application of 6 pathway inhibitors induces post-mitotic cortical neurons with functional electrophysiological properties by day 16 of differentiation, in the absence of glial cell co-culture. The resulting neurons, transplanted at 8 days of differentiation into the postnatal mouse cortex, are functional and establish long-distance projections, as shown using iDISCO whole brain imaging. Accelerated differentiation into cortical neuron fates should facilitate hPSC-based strategies for disease modeling and cell therapy in CNS disorders. PMID:28112759

  19. Optimal Model-Based Fault Estimation and Correction for Particle Accelerators and Industrial Plants Using Combined Support Vector Machines and First Principles Models

    International Nuclear Information System (INIS)

    2010-01-01

    parameters of the beam lifetime model) are physically meaningful. (3) Numerical Efficiency of the Training - We investigated the numerical efficiency of the SVM training. More specifically, for the primal formulation of the training, we have developed a problem formulation that avoids the linear increase in the number of the constraints as a function of the number of data points. (4) Flexibility of Software Architecture - The software framework for the training of the support vector machines was designed to enable experimentation with different solvers. We experimented with two commonly used nonlinear solvers for our simulations. The primary application of interest for this project has been the sustained optimal operation of particle accelerators at the Stanford Linear Accelerator Center (SLAC). Particle storage rings are used for a variety of applications ranging from 'colliding beam' systems for high-energy physics research to highly collimated x-ray generators for synchrotron radiation science. Linear accelerators are also used for collider research such as International Linear Collider (ILC), as well as for free electron lasers, such as the Linear Coherent Light Source (LCLS) at SLAC. One common theme in the operation of storage rings and linear accelerators is the need to precisely control the particle beams over long periods of time with minimum beam loss and stable, yet challenging, beam parameters. We strongly believe that beyond applications in particle accelerators, the high fidelity and cost benefits of a combined model-based fault estimation/correction system will attract customers from a wide variety of commercial and scientific industries. Even though the acquisition of Pavilion Technologies, Inc. by Rockwell Automation Inc. in 2007 has altered the small business status of the Pavilion and it no longer qualifies for a Phase II funding, our findings in the course of the Phase I research have convinced us that further research will render a workable model

  20. Optimal Model-Based Fault Estimation and Correction for Particle Accelerators and Industrial Plants Using Combined Support Vector Machines and First Principles Models

    Energy Technology Data Exchange (ETDEWEB)

    Sayyar-Rodsari, Bijan; Schweiger, Carl; /SLAC /Pavilion Technologies, Inc., Austin, TX

    2010-08-25

    parameters of the beam lifetime model) are physically meaningful. (3) Numerical Efficiency of the Training - We investigated the numerical efficiency of the SVM training. More specifically, for the primal formulation of the training, we have developed a problem formulation that avoids the linear increase in the number of the constraints as a function of the number of data points. (4) Flexibility of Software Architecture - The software framework for the training of the support vector machines was designed to enable experimentation with different solvers. We experimented with two commonly used nonlinear solvers for our simulations. The primary application of interest for this project has been the sustained optimal operation of particle accelerators at the Stanford Linear Accelerator Center (SLAC). Particle storage rings are used for a variety of applications ranging from 'colliding beam' systems for high-energy physics research to highly collimated x-ray generators for synchrotron radiation science. Linear accelerators are also used for collider research such as International Linear Collider (ILC), as well as for free electron lasers, such as the Linear Coherent Light Source (LCLS) at SLAC. One common theme in the operation of storage rings and linear accelerators is the need to precisely control the particle beams over long periods of time with minimum beam loss and stable, yet challenging, beam parameters. We strongly believe that beyond applications in particle accelerators, the high fidelity and cost benefits of a combined model-based fault estimation/correction system will attract customers from a wide variety of commercial and scientific industries. Even though the acquisition of Pavilion Technologies, Inc. by Rockwell Automation Inc. in 2007 has altered the small business status of the Pavilion and it no longer qualifies for a Phase II funding, our findings in the course of the Phase I research have convinced us that further research will render a workable

  1. Combined reconstruction of the anterior cruciate ligament associated with anterolateral tenodesis effectively controls the acceleration of the tibia during the pivot shift.

    Science.gov (United States)

    Hardy, Alexandre; Casabianca, Laurent; Hardy, Edouard; Grimaud, Olivier; Meyer, Alain

    2017-04-01

    The pivot shift test is quantified subjectively during assessment of patients presenting with suspected Anterior Cruciate Ligament (ACL) tears and has a low interobserver reproducibility. The Kinematic Rapid Assessment (KiRA) is a triaxial accelerometer that makes it possible to non-invasively quantify tibial acceleration during the pivot shift test. Abolishing pivot shift is considered to be a key element in surgical reconstruction but is incomplete in 25-38% of patients. Patients were included prospectively. Inclusion criteria were patients requiring ACL reconstruction associated with at least one of the following factors corresponding to the patient who have a high risk of rupture either by their sports activity, a failure case, or the notion of important rotational laxity: the patient practiced a competitive pivot-contact sport, revision ACL reconstruction (besides STG (semitendinosus-gracilis graft) repair), subjective explosive rotational laxity, Segond fracture, and TELOS value of >10 mm. Standardized pre- and postoperative pivot shift tests were immediately performed under anesthesia in both knees. Forty-three patients were included. Mean preoperative variations in tibial acceleration in the healthy and injured knees were 1.2 ± 0.1 and 2.7 ± 0.3 m/s 2 , respectively, p operated knees (n.s). Combined ACL reconstruction associated with anterolateral tenodesis suppress acute pathologic tibial acceleration in the pivot shift. III.

  2. Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, Sahaja; Fischer-Valuck, Benjamin W.; Mazur, Thomas R.; Curcuru, Austen; Sona, Karl; Kashani, Rojano; Green, Olga; Ochoa, Laura; Mutic, Sasa; Zoberi, Imran; Li, H. Harold; Thomas, Maria A., E-mail: mthomas@radonc.wustl.edu

    2016-11-15

    Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

  3. 15-Year biochemical relapse free survival in clinical Stage T1-T3 prostate cancer following combined external beam radiotherapy and brachytherapy; Seattle experience

    International Nuclear Information System (INIS)

    Sylvester, John E.; Grimm, Peter D.; Blasko, John C.; Millar, Jeremy; Orio, Peter F.; Skoglund, Scott; Galbreath, Robert W.; Merrick, Gregory

    2007-01-01

    Purpose: Long-term biochemical relapse-free survival (BRFS) rates in patients with clinical Stages T1-T3 prostate cancer continue to be scrutinized after treatment with external beam radiation therapy and brachytherapy. Methods and Materials: We report 15-year BRFS rates on 223 patients with clinically localized prostate cancer that were consecutively treated with I 125 or Pd 103 brachytherapy after 45-Gy neoadjuvant EBRT. Multivariate regression analysis was used to create a pretreatment clinical prognostic risk model using a modified American Society for Therapeutic Radiology and Oncology consensus definition (two consecutive serum prostate-specific antigen rises) as the outcome. Gleason scoring was performed by the pathologists at a community hospital. Time to biochemical failure was calculated and compared by using Kaplan-Meier plots. Results: Fifteen-year BRFS for the entire treatment group was 74%. BRFS using the Memorial Sloan-Kettering risk cohort analysis (95% confidence interval): low risk, 88%, intermediate risk 80%, and high risk 53%. Grouping by the risk classification described by D'Amico, the BRFS was: low risk 85.8%, intermediate risk 80.3%, and high risk 67.8% (p = 0.002). Conclusions: I 125 or Pd 103 brachytherapy combined with supplemental EBRT results in excellent 15-year biochemical control. Different risk group classification schemes lead to different BRFS results in the high-risk group cohorts

  4. Accelerated split-course (Type B) thoracic radiation therapy plus vinorelbine/carboplatin combination chemotherapy in Stage III inoperable non-small cell lung cancer

    International Nuclear Information System (INIS)

    Iaffaioli, R.V.; Tortoriello, A.; Facchini, G.; Maccauro, M.; Dimitri, P.; Ravo, V.; Muto, P.; Crovella, F.

    1996-01-01

    43 patients with stage III NSCLC (non-small cell lung cancer) entered a phase II study aimed at evaluating the toxicity and the activity of a combined modality programme including an accelerated split-course schedule (type B) of thoracic radiation therapy and a combination chemotherapy with vinorelbine and carboplatin. An objective response was achieved in 18/42 evaluable patients (5 complete and 13 partial responses), for an overall response rate of 43% (95% confidence interval, 28-58%). Four complete responses had a duration which exceeded 16 months. Treatment was well tolerated; grade III myelotoxicity occurred in only 14% of patients and treatment was delayed in only 2 cases because of grade 3 oesophagitis. Both tolerability and efficacy data suggest that this regimen holds promise for the treatment of patients with stage III NSCLC. (author)

  5. Tranexamic acid combined with recombinant factor VIII increases clot resistance to accelerated fibrinolysis in severe hemophilia A

    DEFF Research Database (Denmark)

    Hvas, Anne-Mette; Sørensen, Hanne Thykjær; Norengaard, Lisbeth

    2007-01-01

    examined whether the clot stability in hemophiliacs could be improved by treatment with tranexamic acid (TXA) in combination with recombinant factor VIII (rFVIII). PATIENTS/METHODS: Baseline blood samples were obtained from eight males with severe hemophilia A. Thereafter, a bolus injection of r...

  6. High-salt diet combined with elevated angiotensin II accelerates atherosclerosis in apolipoprotein E-deficient mice

    DEFF Research Database (Denmark)

    Johansson, Maria E; Bernberg, Evelina; Andersson, Irene J

    2009-01-01

    to atherosclerosis. METHODS: Apolipoprotein E-deficient (ApoE-/-) mice received standard or high-salt diet (8%) alone or in combination with fixed angiotensin II (Ang II) infusion (0.5 microg/kg per min). BP was measured using telemetry, and plaque burden was assessed in the thoracic aorta and innominate artery. We...

  7. Motivational interviewing combined with chess accelerates improvement in executive functions in cocaine dependent patients: a one-month prospective study.

    Science.gov (United States)

    Gonçalves, Priscila Dib; Ometto, Mariella; Bechara, Antoine; Malbergier, André; Amaral, Ricardo; Nicastri, Sergio; Martins, Paula A; Beraldo, Livia; dos Santos, Bernardo; Fuentes, Daniel; Andrade, Arthur G; Busatto, Geraldo F; Cunha, Paulo Jannuzzi

    2014-08-01

    In cocaine-dependent individuals, executive function (EF) deficits are associated with poor treatment outcomes. Psychological interventions and pharmacological approaches have produced only modest effect sizes. To date, studies of this topic have been few and limited. The aim of this study was to examine the effects of a new model of intervention, which integrates chess and Motivational Interviewing, Motivational Chess (MC) METHODS: We evaluated 46 cocaine-dependent inpatients (aged 18-45), in two groups-MC (n=26); and active comparison-AC (n=20). Using neuropsychological tests and an impulsivity scale, we assessed the subjects before and after the study period (one month of abstinence monitored by urine toxicology screening). The MC and AC groups did not differ at baseline. In the post-intervention assessment (after one month), both groups showed significant improvements in attention, mental flexibility, inhibitory control, abstraction abilities, and decision-making (p<0.01). In addition, the improvement in working memory was more significant in the MC group than in the AC group (group-by-time interaction, p=01). One month of abstinence was sufficient to improve various attentional and executive domains in cocaine-dependent subjects. The MC intervention was associated with greater improvements in EFs, especially working memory, suggesting that tailored interventions focusing on complex EFs accelerate the process of cognitive recovery during the initial period of abstinence. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Orchestrated structure evolution: accelerating direct-write nanomanufacturing by combining top-down patterning with bottom-up growth

    Energy Technology Data Exchange (ETDEWEB)

    Kitayaporn, Sathana; Baneyx, Francois; Schwartz, Daniel T [Department of Chemical Engineering, University of Washington, Seattle, WA 98195-1750 (United States); Hoo, Ji Hao; Boehringer, Karl F, E-mail: dts@uw.edu [Department of Electrical Engineering, University of Washington, Seattle, WA 98195-1750 (United States)

    2010-05-14

    Direct-write nanomanufacturing with scanning beams and probes is flexible and can produce high quality products, but it is normally slow and expensive to raster point-by-point over a pattern. We demonstrate the use of an accelerated direct-write nanomanufacturing method called 'orchestrated structure evolution' (OSE), where a direct-write tool patterns a small number of growth 'seeds' that subsequently grow into the final thin film pattern. Through control of seed size and spacing, it is possible to vary the ratio of 'top-down' to 'bottom-up' character of the patterning processes, ranging from conventional top-down raster patterning to nearly pure bottom-up space-filling via seed growth. Electron beam lithography (EBL) and copper electrodeposition were used to demonstrate trade-offs between process time and product quality over nano- to microlength scales. OSE can reduce process times for high-cost EBL patterning by orders of magnitude, at the expense of longer (but inexpensive) copper electrodeposition processing times. We quantify the degradation of pattern quality that accompanies fast OSE patterning by measuring deviations from the desired patterned area and perimeter. We also show that the density of OSE-induced grain boundaries depends upon the seed separation and size. As the seed size is reduced, the uniformity of an OSE film becomes more dependent on details of seed nucleation processes than normally seen for conventionally patterned films.

  9. High-salt diet combined with elevated angiotensin II accelerates atherosclerosis in apolipoprotein E-deficient mice

    DEFF Research Database (Denmark)

    Johansson, Maria E; Bernberg, Evelina; Andersson, Irene J

    2009-01-01

    OBJECTIVES: High-salt diet likely elevates blood pressure (BP), thus increasing the risk of cardiovascular events. We hypothesized that a high-salt diet plays a critical role in subjects whose renin-angiotensin systems cannot adjust to variable salt intake, rendering them more susceptible...... to atherosclerosis. METHODS: Apolipoprotein E-deficient (ApoE-/-) mice received standard or high-salt diet (8%) alone or in combination with fixed angiotensin II (Ang II) infusion (0.5 microg/kg per min). BP was measured using telemetry, and plaque burden was assessed in the thoracic aorta and innominate artery. We...... used urinary isoprostane as a marker for oxidative stress. RESULTS: Although high-salt diet per se did not affect plaque extension, high salt combined with Ang II increased plaque area significantly in both the aorta and the innominate artery as compared with Ang II or salt alone (P

  10. Prospective study of accelerated postoperative radiation therapy in patients with squamous-cell carcinoma of the head and neck; Radiotherapie externe acceleree postoperatoire des carcinomes epidermoides localement evolues de la sphere ORL: etude prospective de phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Zouhair, A.; Coucke, P.A.; Azria, D.; Moeckli, R.; Mirimanoff, R.O.; Ozsahin, M. [Centre Hospitalier Universitaire Vaudois CHUV, Service de Radio-Oncologie, Lausanne (Switzerland); Azria, D. [Centre Regional de Lutte Contre le Cancer Val-d' Aurelle-Paul-Lamarque, Dept. d' Oncologie- Radiotherapie, 34 - Montpellier (France); Pache, P. [Centre Hospitalier Universitaire Vaudois CHUV, Service d' ORL, Lausanne (Switzerland); Stupp, R. [Centre hospitalier Universitaire Vaudois CHUV, Centre Pluridisciplinaire d' Oncologie Medicale, Lausanne (Switzerland)

    2003-08-01

    Purpose. - To assess the feasibility and efficacy of accelerated postoperative radiation therapy (RT) in patients with squamous-cell carcinoma of the head and neck (SCCHN). Patients and methods. - Between December 1997 and July 2001, 68 patients (male to female ratio: 52/16; median age: 60-years (range: 43-81)) with pT1-pT4 and/or pN0-pN3 SCCHN (24 oropharynx, 19 oral cavity, 13 hypopharynx, 5 larynx, 3 unknown primary, 2 maxillary sinus, and 2 salivary gland) were included in this prospective study. Postoperative RT was indicated because extra-capsular infiltration (ECT) was observed in 20 (29%), positive surgical margins (PSM) in 20 (29%) or both in 23 patients (34%). Treatment consisted of external beam R 66 Gy in 5 weeks and 3 days. Median follow-up was 15 months. Results. -According to CTC 2.0, acute morbidity was acceptable: grade 3 mucositis was observed in 15 (22%) patients, grade 3 dysphagia in 19 (28%) patients, grade 3 skin erythema in 21 (31%) patients with a median weight loss of 3.1 kg (range: 0-16). No grade 4 toxicity wa observed. Median time to relapse was 13 months; we observed only three (4%) local and four (6%) regional relapses, whereas eight (12%) patients developed distant metastases without any evidence of locoregional recurrence. The 2 years overall-, disease-free survival, an actuarial locoregional control rates were 85, 73 and 83% respectively. Conclusion.- The reduction of the overall treatment time using postoperative accelerated RT with weekly concomitant boost (six fraction per week) is feasible with local control rates comparable to that of published data. Acute RT related morbidity is acceptable. (author)

  11. Effect of compensatory acceleration training in combination with accommodating resistance on upper body strength in collegiate athletes

    Science.gov (United States)

    Jones, Margaret T

    2014-01-01

    Purpose To determine the impact of inclusion of a band or chain compensatory acceleration training (CAT), in a 5-week training phase, on maximal upper body strength during a 14-week off-season strength and conditioning program for collegiate male athletes. Patients and methods Twenty-four National Collegiate Athletic Association (NCAA) collegiate baseball players, who were familiar with the current strength and conditioning program and had a minimum of 1 year of formal collegiate strength and conditioning experience, participated in this off-season training study. None of the men had participated in CAT before. Subjects were matched following a maximal effort (1-repetition maximum [1-RM]) bench press test in week 1, then were randomly assigned into a band-based CAT group or a chain-based CAT group and participated in a 5-week training phase that included bench pressing twice per week. Upper body strength was measured by 1-RM bench press again at week 6. A 2 × 2 mixed factorial (method × time) analysis of variance was calculated to compare differences across groups. The alpha level was set at Pbench (F1,22=88.46, P=0.001). Conclusion A 5-week band CAT or chain CAT training program used in conjunction with an off-season strength and conditioning program can increase maximal upper body strength in collegiate baseball athletes. Using band CAT and/or chain CAT as a training modality in the off-season will vary the training stimulus from the traditional and likely help to maintain the athlete’s interest. PMID:25177154

  12. A randomized controlled trial of the effect of combined spinal-epidural analgesia on the success of external cephalic version for breech presentation.

    Science.gov (United States)

    Sullivan, J T; Grobman, W A; Bauchat, J R; Scavone, B M; Grouper, S; McCarthy, R J; Wong, C A

    2009-10-01

    Improving the success of external cephalic version (ECV) for breech presentation may help avoid some cesarean deliveries. The results of randomized trials comparing the success of ECV with neuraxial analgesia compared to control are inconsistent. We hypothesized that combined spinal-epidural (CSE) analgesia would increase the success of ECV when compared with systemic opioid analgesia. Parturients with singleton breech presentation (n=96) were randomized to receive CSE analgesia with bupivacaine 2.5mg and fentanyl 15 microg (CSE group) or intravenous fentanyl 50 microg (SYS group) before ECV attempt. The primary outcome was ECV success. The success rate of ECV was 47% with CSE and 31% in the SYS group (P=0.14). Subsequent vaginal delivery was 36% for CSE and 25% for SYS (P=0.27). Median [IQR] visual analog pain scores (0-100mm scale) were lower with CSE (3 [0-12]) compared to SYS analgesia (36 [16 to 54]) (P<0.005) and patient satisfaction (0-10 scale) was higher (CSE 10 [9 to 10] versus SYS 7 [4 to 9]) (P<0.005). There were no differences in fetal heart rate patterns, but median time to return to fetal heart rate reactivity after analgesia was shorter with CSE (13 [IQR 9-21] min) compared to the SYS group (39 [IQR 23-51] min) (P=0.02). There was no difference in the rate of successful ECV or vaginal delivery with CSE compared to intravenous fentanyl analgesia. Pain scores were lower and satisfaction higher with CSE analgesia, and median time to fetal heart rate reactivity was shorter in the CSE group.

  13. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis.

    Science.gov (United States)

    Zhang, Shao-Bo; Zhang, Yi-Bao; Wang, Sheng-Hong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-04-01

    To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the rate of nonunion, malunion/delayed union and the excellent/good rate assessed by Mazur ankle score. The complications including infections and arthritis symptoms after surgery were also investigated. Nine trials including 498 pilon fractures of 494 patients were identified. The meta-analysis found no significant differences in nonunion rate (RR = 1.60, 95% CI: 0.66 to 3.86, p = 0.30), and the excellent/good rate (RR = 0.95, 95% CI: 0.86 to 1.04, p = 0.28) between LIFEF group and ORIF group. For assessment of infections, there were significant differences in the rate of deep infection (RR = 2.18, 95% CI: 1.34 to 3.55, p = 0.002), and the rate of arthritis (RR = 1.26, 95% CI: 1.03 to 1.53, p = 0.02) between LIFEF group and ORIF group. LIFEF has similar effect as ORIF in the treatment of pilon fractures, however, LIFEF group has significantly higher risk of complications than ORIF group does. So LIFEF is not recommended in the treatment of pilon fracture. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  14. The combination of energy-dependent internal adaptation mechanisms and external factors enables Listeria monocytogenes to express a strong starvation survival response during multiple-nutrient starvation.

    Science.gov (United States)

    Lungu, Bwalya; Saldivar, Joshua C; Story, Robert; Ricke, Steven C; Johnson, Michael G

    2010-05-01

    The goal of this study was to characterize the starvation survival response (SSR) of a wild-type Listeria monocytogenes 10403S and an isogenic DeltasigB mutant strain during multiple-nutrient starvation conditions over 28 days. This study examined the effects of inhibitors of protein synthesis, the proton motive force, substrate level phosphorylation, and oxidative phosphorylation on the SSR of L. monocytogenes 10403S and a DeltasigB mutant during multiple-nutrient starvation. The effects of starvation buffer changes on viability were also examined. During multiple-nutrient starvation, both strains expressed a strong SSR, suggesting that L. monocytogenes possesses SigB-independent mechanism(s) for survival during multiple-nutrient starvation. Neither strain was able to express an SSR following starvation buffer changes, indicating that the nutrients/factors present in the starvation buffer could be a source of energy for cell maintenance and survival. Neither the wild-type nor the DeltasigB mutant strain was able to elicit an SSR when exposed to the protein synthesis inhibitor chloramphenicol within the first 4 h of starvation. However, both strains expressed an SSR when exposed to chloramphenicol after 6 h or more of starvation, suggesting that the majority of proteins required to elicit an effective SSR in L. monocytogenes are likely produced somewhere between 4 and 6 h of starvation. The varying SSRs of both strains to the different metabolic inhibitors under aerobic or anaerobic conditions suggested that (1) energy derived from the proton motive force is important for an effective SSR, (2) L. monocytogenes utilizes an anaerobic electron transport during multiple-nutrient starvation conditions, and (3) the glycolytic pathway is an important energy source during multiple-nutrient starvation when oxygen is available, and less important under anaerobic conditions. Collectively, the data suggest that the combination of energy-dependent internal adaptation mechanisms

  15. Accelerator mass spectrometry at the Rossendorf 5 MV tandem accelerator

    International Nuclear Information System (INIS)

    Friedrich, M.; Buerger, W.; Curian, H.; Hartmann, B.; Hentschel, E.; Matthes, H.; Probst, W.; Seidel, M.; Turuc, S.; Hebert, D.; Rothe, T.; Stolz, W.

    1992-01-01

    The Rossendorf electrostatic accelerators (5 MV tandem accelerator and single ended 2 MV van de Graaff accelerator) are already used for ion beam analysis. The existing methods (RBS, PIXE, ERDA, NRA, nuclear microprobe and external beam) will be completed by introduction of Accelerator Mass Spectrometry (AMS). A short description of the Rossendorf AMS system is given and first experimental results are presented. (R.P.) 4 refs.; 6 figs

  16. Examining the evidence for a recent acceleration in the rate of sea-level rise using combined instrumental and proxy data, North Carolina, USA

    Science.gov (United States)

    Kemp, A.; Horton, B. P.

    2007-12-01

    Whilst accelerated rates of relative sea-level (RSL) rise are potentially one of the most devastating impacts of future climate change, our understanding of decadal scale changes in sea-level is poor. This paper seeks to address this knowledge gap by combining tide gauge and high-precision geological reconstructions of relative sea-level of sufficient resolution and duration to detect any recent acceleration in the rate of sea-level rise. We offer a high resolution relative sea-level history for the last ~2000 years from the Albemarle - Pamlico Estuarine System in North Carolina. Contemporary foraminifera were collected from five back barrier marshes to create a regional scale modern training set. The use of multiple marshes from a region increases the ecological and environmental diversity included within the training set and reduces the probability of a no modern analogue outcome. To merge the five spatially distinct sites and to relate each to local tide levels we used the VDatum transformation tool. This method relates all samples to a common orthometric datum (NAVD88) and reduces error. We developed an accurate and precise transfer function to reconstruct former sea levels based upon the modern observable relationship between foraminifera and elevation with respect to the tidal frame. We applied the transfer function to salt-marsh core(s) from Sand Point (Roanoke Island), North Carolina to produce a late Holocene RSL record. An age-depth model was produced from composite chronologies of 210Pb, 14C and pollen chrono-horizons. We validated our approach by comparing geological based reconstructions and instrumental tide gauge records. Our records show that in the last ~2000 years sea level has risen at a background rate of ~1.1mm/yr. There is evidence for two recent accelerations in the rate of sea-level rise during the late 19th and 20th centuries to a current rate of ~4mm/yr.

  17. Effect of compensatory acceleration training in combination with accommodating resistance on upper body strength in collegiate athletes

    Directory of Open Access Journals (Sweden)

    Jones MT

    2014-08-01

    Full Text Available Margaret T Jones Sports Medicine Assessment, Rehabilitation, and Testing Laboratory, School of Recreation, Health, and Tourism, George Mason University, Manassas, VA, USA Purpose: To determine the impact of inclusion of a band or chain compensatory acceleration training (CAT, in a 5-week training phase, on maximal upper body strength during a 14-week off-season strength and conditioning program for collegiate male athletes. Patients and methods: Twenty-four National Collegiate Athletic Association (NCAA collegiate baseball players, who were familiar with the current strength and conditioning program and had a minimum of 1 year of formal collegiate strength and conditioning experience, participated in this off-season training study. None of the men had participated in CAT before. Subjects were matched following a maximal effort (1-repetition maximum [1-RM] bench press test in week 1, then were randomly assigned into a band-based CAT group or a chain-based CAT group and participated in a 5-week training phase that included bench pressing twice per week. Upper body strength was measured by 1-RM bench press again at week 6. A 2 × 2 mixed factorial (method × time analysis of variance was calculated to compare differences across groups. The alpha level was set at P<0.05. Results: No difference (F1,22=0.04, P=0.84 existed between the band-based CAT and chain-based CAT groups. A significant difference was observed between pre- and posttests of 1-RM bench (F1,22=88.46, P=0.001. Conclusion: A 5-week band CAT or chain CAT training program used in conjunction with an off-season strength and conditioning program can increase maximal upper body strength in collegiate baseball athletes. Using band CAT and/or chain CAT as a training modality in the off-season will vary the training stimulus from the traditional and likely help to maintain the athlete's interest. Keywords: variable resistance, band, baseball, chain, resistance training

  18. Does prostate brachytherapy treat the seminal vesicles? A dose-volume histogram analysis of seminal vesicles in patients undergoing combined PD-103 prostate implantation and external beam irradiation

    International Nuclear Information System (INIS)

    Stock, Richard G.; Lo, Yeh-Chi; Gaildon, Mohamoud; Stone, Nelson N.

    1999-01-01

    Purpose: Combined brachytherapy of the prostate and external beam irradiation (EBRT) of the prostate and seminal vesicles (SV) is becoming a popular treatment for high-risk prostate cancer. Dose-volume histogram (DVH) analysis of the SV in patients undergoing this treatment was performed to determine the dose distribution to the SV and the adequacy of this treatment in patients with potential SV involvement. Methods and Materials: Twenty-five consecutive patients were treated with a Pd-103 implant of the prostate alone and 45 Gy of EBRT to the prostate and SV. Attempts were not made to implant the SV but seeds were routinely placed at the junction of the prostate and SV. All patients underwent CT-based post implant dosimetric analysis 1 month after implantation. As part of this analysis, DVH were generated for the prostate and total SV volume (SVT). In addition, the SV was divided into 6-mm-thick volumes identified as SV1, SV2, SV3, SV4, and SV5 starting from the junction of the prostate and SV and extending distally. DVH were also generated for these structures. Delivered dose was defined as the D90 (dose delivered to 90% of the organ on DVH). Results: The median volumes in cc of the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 34.33, 9.75, 2.7, 3.48, 2.92, 3.18, and 1.96 respectively. The SVT contained from 0-9 seeds (median 2). There was little dose delivered to the SVT and SV volumes from the implanted prostate. The median D90 values for the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 8615 cGy, 675 cGy, 3100 cGy, 1329 cGy, 553 cGy, 246 cGy, and 67 cGy, respectively. The dose delivered to the prostate covered small percentages of SV. The percents of SV volumes covered by the prostate D90 were 11, 35, 3.3, 0, 0, and 0 for SVT, SV1, SV2, SV3, SV4, and SV5, respectively. Conclusions: DVH analysis of the SV reveals that dose generated from an implanted prostate contributes little to the SV. Those patients at high risk for SV involvement may be under treated

  19. Late rectal bleeding and genitourinary morbidity after high dose rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Ebara, Takeshi; Akimoto, Tetsuo; Kato, Hiroyuki

    2007-01-01

    The purpose of this study was to evaluate late rectal bleeding and genitourinary (GU) morbidity in patients consecutively treated with combined high-dose-rate (HDR) brachytherapy and external beam radiation therapy (EBRT). Data from 80 patients treated consecutively from October 2000 to May 2004 were analyzed. The median age was 69 years old, median follow-up 31 months, ranging from 17-59 months. All patients received endocrine therapy before radiation therapy. The patients were divided into low-, intermediate- and high-risk groups (4/24/52 patients) according to the risk factors defined by T-classification, prostatic specific antigen (PSA) and Gleason score. Fractionation schedules for HDR brachytherapy were prospectively changed, and EBRT was fixed with 3 Gy fractions to 51 Gy. The distribution of fractionation was scheduled as follows; 5 Gy x 5 times in 14 patients, 7 Gy x 3 times in 19 patients, and 9 Gy x 2 times in 47 patients. The rectal bleeding was graded using the toxicity criteria of the Radiation Therapy Oncology Group and European Organization for Research and Treatment of Cancer while the genitourinary morbidities were graded using the toxicity criteria of the Common Terminology Criteria for Adverse Events v.3.0. Grade 2 or worse rectal bleeding developed in 9 patients (11.3%) with the 2-year actuarial probability at 11.2%. Grade 2 and 3 rectal bleeding was recognized in 8 and 1 patients, respectively. Grade 3 morbidity developed in the biopsied sites that were performed in the other hospital. No significant difference was observed in any HDR brachytherapy fractionation schedule. Grade 2 or worse GU morbidities were recognized in 30 patients (37.5%), consisting of 29 Grade 2 patients and 1 Grade 3 patient. Twenty-one patients in Grade 2 morbidity had an increase in the frequency of urination or nocturia, and urethral strictures developed in 3 patients. The 3-year actuarial probability of urethral stricture was 6.0%. One patient experienced Grade 3

  20. Feasibility and efficacy of accelerated weekly concomitant boost postoperative radiation therapy combined with concomitant chemotherapy in patients with locally advanced head and neck cancer.

    Science.gov (United States)

    Pehlivan, Berrin; Luthi, Francois; Matzinger, Oscar; Betz, Michael; Dragusanu, Daniela; Bulling, Shelley; Bron, Luc; Pasche, Philippe; Seelentag, Walter; Mirimanoff, René O; Zouhair, Abderrahim; Ozsahin, Mahmut

    2009-05-01

    The aim of this study was to assess feasibility and efficacy of weekly concomitant boost accelerated postoperative radiation therapy (PORT) with concomitant chemotherapy (CT) in patients with locally advanced head and neck cancer (LAHNC). Conformal or intensity-modulated 66-Gy RT was performed in 5.5 weeks in 40 patients. Cisplatin was given at days 1, 22, and 43. Median follow-up was 36 months. Grade 3 mucositis, dysphagia, and erythema was observed in ten (25%), nine (23%), and six (13%) patients, respectively. Grade 3 or more anemia was observed in two (6%) patients, and leukopenia in five (13%) patients. No grade 3 or 4 thrombocytopenia was observed. Grade 3 nephrotoxicity was observed in one patient (3%). No treatment-related mortality was observed. Grade 2 or more xerostomia and edema were observed in ten (25%) and one (3%) patient, respectively. Locoregional relapse occurred in eight patients, and seven patients developed distant metastases. Median time to locoregional relapse was 6 months. Three-year overall, disease-free survival, and locoregional control rates were 63%, 62%, and 81%, respectively. Multivariate analysis revealed that the only prognostic factor was nodal status. Reducing overall treatment time using accelerated PORT/CT by weekly concomitant boost (six fractions per week) combined with concomitant cisplatin CT is easily feasible with acceptable morbidity.

  1. Early discharge after external anal sphincter repair

    DEFF Research Database (Denmark)

    Rosenberg, J; Kehlet, H

    1999-01-01

    PURPOSE: The aim of this study was to describe an accelerated-stay program for repair of the external anal sphincter. METHODS: Twenty consecutive patients undergoing overlapping repair of the external anal sphincter were included in the study. Effect parameters were length of hospitalization....... CONCLUSION: We have described a safe accelerated-stay program (24 to 48 hours) for overlapping repair of external anal sphincter....

  2. The effect of combined external beam and high-dose intracavitary brachytherapy on dysphagia and survival in patients with advanced esophageal cancer

    International Nuclear Information System (INIS)

    Yorozu, Atsunori; Dokiya, Takushi; Ogita, Mikio; Kutsuki, Shoji

    1996-01-01

    During an 11-year period, a group of 130 patients with esophageal cancer of stages 2 to 4 were treated with external beam irradiation (40 to 60 Gy) followed by boost dose of 10 to 20 Gy of high-dose intracavitary brachytherapy. The overall 2-year survival rate was 15.4%. The significant prognostic factors were tumor size, response to external beam irradiation, pretreatment dysphagia score, and presence of distant metastases. The palliative effect was excellent; the dysphagia scores of 122 of 130 patients (93.8%) improved. The significant palliative factors were response to external beam irradiation and pretreatment dysphagia score. Tracheoesophageal fistulas developed after treatment in 13 of 130 patients (10%); 3 of the fistulas were probably related to radiotherapy. We conclude that intracavitary brachytherapy is useful in the treatment of cases of advanced cancer which show a good response to external beam irradiation and may be curative in patients with mild dysphagia. (author)

  3. Plasma wakefields driven by an incoherent combination of laser pulses: a path towards high-average power laser-plasma accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Benedetti, C.; Schroeder, C.B.; Esarey, E.; Leemans, W.P.

    2014-05-01

    he wakefield generated in a plasma by incoherently combining a large number of low energy laser pulses (i.e.,without constraining the pulse phases) is studied analytically and by means of fully-self-consistent particle-in-cell simulations. The structure of the wakefield has been characterized and its amplitude compared with the amplitude of the wake generated by a single (coherent) laser pulse. We show that, in spite of the incoherent nature of the wakefield within the volume occupied by the laser pulses, behind this region the structure of the wakefield can be regular with an amplitude comparable or equal to that obtained from a single pulse with the same energy. Wake generation requires that the incoherent structure in the laser energy density produced by the combined pulses exists on a time scale short compared to the plasma period. Incoherent combination of multiple laser pulses may enable a technologically simpler path to high-repetition rate, high-average power laser-plasma accelerators and associated applications.

  4. Prostate preservation by combined external beam and hdr brachytherapy at nodal negative prostate cancer patients - an intermediate analysis after ten years experience

    International Nuclear Information System (INIS)

    Kovacs, G.; Wirth, B.; Bertermann, H.; Galalae, R.; Kohr, P.; Wilhelm, R.; Kimmig, B.

    1996-01-01

    Purpose/Objective: The combined external beam (EBT) and HDR brachytherapy (HBT) boost treatment for localized prostate cancer was established in 1986. The aim of this analysis is to judge the results of this method after 10 years experience. Material and Methods: The treatment and follow-up data of 171 histologically proven, localized (N-staging by imaging) prostate cancer patients were analyzed. Average age of the patients was 68.2 years with a median of 69 years (44-84 years). Tumor stages (using transrectal ultrasound /TRUS/) ranged from A2 (T1b) in two, to B (T2) in 110 and C (T3) in 59 cases. Tumor grading: 27 highly differentiated (G1), 86 moderately differentiated (G2) as well as 57 poorly differentiated (G3) and one undifferentiated (G4) tumor. Follow-up lasted 13-114 months (mean: 53; median: 55 months). Forty-six patients had previous surgery on the bladder neck. Sixty-one patients had transitory androgen deprivation or antiandrogen treatment prior to radiation, which lasted for a max. of 6 months and was finished before radiation with the exception of 13 patients who continued the hormone deprivation after radiotherapy. Initial PSA was known in 126 cases, 86 of them had not received previous androgen deprivation. In 13% values under 4 ng/ml (Hybritech), as well as 46% not above 20 ng/ml and 40 % above 20 ng/ml, respectively. Those cases in which PSA began to rise without having been fallen under a level of 1 ng/ml were considered as PSA progression as well as those cases in which PSA rose to a value twice the PSA nadir we found be essential (2 ng/ml) after it had fallen to a minimum under 1 ng/ml. Ultrasound guided conformal HBT treatment planning was carried out. The 2x 15 Gy HBT boost was integrated into the EBT schedule, total dose was 50 Gy for subclinical disease and 70 Gy for the prostate in 6-7 weeks. Regular follow-up by clinical examination, TRUS + volumetry, PSA, bone scan and after 12 months biopsy. Results: Ten of 171 patients died of

  5. A meta-analysis of hyperfractionated and accelerated radiotherapy and combined chemotherapy and radiotherapy regimens in unresected locally advanced squamous cell carcinoma of the head and neck

    International Nuclear Information System (INIS)

    Budach, W; Hehr, T; Budach, V; Belka, C; Dietz, K

    2006-01-01

    Former meta-analyses have shown a survival benefit for the addition of chemotherapy (CHX) to radiotherapy (RT) and to some extent also for the use of hyperfractionated radiation therapy (HFRT) and accelerated radiation therapy (AFRT) in locally advanced squamous cell carcinoma (SCC) of the head and neck. However, the publication of new studies and the fact that many older studies that were included in these former meta-analyses used obsolete radiation doses, CHX schedules or study designs prompted us to carry out a new analysis using strict inclusion criteria. Randomised trials testing curatively intended RT (≥60 Gy in >4 weeks/>50 Gy in <4 weeks) on SCC of the oral cavity, oropharynx, hypopharynx, and larynx published as full paper or in abstract form between 1975 and 2003 were eligible. Trials comparing RT alone with concurrent or alternating chemoradiation (5-fluorouracil (5-FU), cisplatin, carboplatin, mitomycin C) were analyzed according to the employed radiation schedule and the used CHX regimen. Studies comparing conventionally fractionated radiotherapy (CFRT) with either HFRT or AFRT without CHX were separately examined. End point of the meta-analysis was overall survival. Thirty-two trials with a total of 10 225 patients were included into the meta-analysis. An overall survival benefit of 12.0 months was observed for the addition of simultaneous CHX to either CFRT or HFRT/AFRT (p < 0.001). Separate analyses by cytostatic drug indicate a prolongation of survival of 24.0 months, 16.8 months, 6.7 months, and 4.0 months, respectively, for the simultaneous administration of 5-FU, cisplatin-based, carboplatin-based, and mitomycin C-based CHX to RT (each p < 0.01). Whereas no significant gain in overall survival was observed for AFRT in comparison to CFRT, a substantial prolongation of median survival (14.2 months, p < 0.001) was seen for HFRT compared to CFRT (both without CHX). RT combined with simultaneous 5-FU, cisplatin, carboplatin, and mitomycin C as

  6. Accelerating Monte Carlo Molecular Simulations Using Novel Extrapolation Schemes Combined with Fast Database Generation on Massively Parallel Machines

    KAUST Repository

    Amir, Sahar Z.

    2013-05-01

    We introduce an efficient thermodynamically consistent technique to extrapolate and interpolate normalized Canonical NVT ensemble averages like pressure and energy for Lennard-Jones (L-J) fluids. Preliminary results show promising applicability in oil and gas modeling, where accurate determination of thermodynamic properties in reservoirs is challenging. The thermodynamic interpolation and thermodynamic extrapolation schemes predict ensemble averages at different thermodynamic conditions from expensively simulated data points. The methods reweight and reconstruct previously generated database values of Markov chains at neighboring temperature and density conditions. To investigate the efficiency of these methods, two databases corresponding to different combinations of normalized density and temperature are generated. One contains 175 Markov chains with 10,000,000 MC cycles each and the other contains 3000 Markov chains with 61,000,000 MC cycles each. For such massive database creation, two algorithms to parallelize the computations have been investigated. The accuracy of the thermodynamic extrapolation scheme is investigated with respect to classical interpolation and extrapolation. Finally, thermodynamic interpolation benefiting from four neighboring Markov chains points is implemented and compared with previous schemes. The thermodynamic interpolation scheme using knowledge from the four neighboring points proves to be more accurate than the thermodynamic extrapolation from the closest point only, while both thermodynamic extrapolation and thermodynamic interpolation are more accurate than the classical interpolation and extrapolation. The investigated extrapolation scheme has great potential in oil and gas reservoir modeling.That is, such a scheme has the potential to speed up the MCMC thermodynamic computation to be comparable with conventional Equation of State approaches in efficiency. In particular, this makes it applicable to large-scale optimization of L

  7. Prognostic Significance of 5-Year PSA Value for Predicting Prostate Cancer Recurrence After Brachytherapy Alone and Combined With Hormonal Therapy and/or External Beam Radiotherapy

    International Nuclear Information System (INIS)

    Stock, Richard G.; Klein, Thomas J.; Cesaretti, Jamie A.; Stone, Nelson N.

    2009-01-01

    Purpose: To analyze the prognosis and outcomes of patients who remain free of biochemical failure during the first 5 years after treatment. Methods and Materials: Between 1991 and 2002, 742 patients with prostate cancer were treated with brachytherapy alone (n = 306), brachytherapy and hormonal therapy (n = 212), or combined implantation and external beam radiotherapy (with or without hormonal therapy; n = 224). These patients were free of biochemical failure (American Society for Therapeutic Radiology and Oncology [ASTRO] definition) during the first 5 post-treatment years and had a documented 5-year prostate-specific antigen (PSA) value. The median follow-up was 6.93 years. Results: The actuarial 10-year freedom from PSA failure rate was 97% using the ASTRO definition and 95% using the Phoenix definition. The median 5-year PSA level was 0.03 ng/mL (range, 0-3.6). The 5-year PSA value was ≤0.01 in 47.7%, >0.01-0.10 in 31.1%, >0.10-0.2 in 10.2%, >0.2-0.5 in 7.82%, and >0.5 in 3.10%. The 5-year PSA value had prognostic significance, with a PSA value of ≤0.2 ng/mL (n = 661) corresponding to a 10-year freedom from PSA failure rate of 99% with the ASTRO definition and 98% with the Phoenix definition vs. 86% (ASTRO definition) and 81% (Phoenix definition) for a PSA value ≥0.2 ng/mL (n = 81; p < .0001). The treatment regimen had no effect on biochemical failure. None of the 742 patients in this study developed metastatic disease or died of prostate cancer. Conclusion: The results of this study have shown that the prognosis for patients treated with brachytherapy and who remain biochemically free of disease for ≥5 years is excellent and none developed metastatic disease during the first 10 years after treatment. The 5-year PSA value is prognostic, and patients with a PSA value <0.2 ng/mL are unlikely to develop subsequent biochemical relapse.

  8. An active particle accelerator

    International Nuclear Information System (INIS)

    Goldman, T.

    1991-01-01

    Although a static charge is difficult to maintain on macroscopic particles, it is straightforward to construct a small object with a regularly oscillating electric dipole moment. For objects of a given size, one may then construct an accelerator by appropriately matching the frequency and separations of an external array of electrodes to this size. Physically feasible size ranges, an accelerator design, and possible applications of such systems are discussed. 8 refs., 9 figs

  9. Accelerator update

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    When the Accelerator Conference, combined International High Energy and US Particle versions, held in Dallas in May, was initially scheduled, progress nearby for the US Superconducting Supercollider was high on the preliminary agenda. With the SSC voted down by Congress in October 1993, this was no longer the case. However the content of the meeting, in terms of both its deep implications for ambitious new projects and the breadth of its scope, showed that the worldwide particle accelerator field is far from being moribund. A traditional feature of such accelerator conferences is the multiplicity of parallel sessions. No one person can attend all sessions, so that delegates can follow completely different paths and emerge with totally different impressions. Despite this overload, and despite the SSC cancellation, the general picture is one of encouraging progress over a wide range of major new projects throughout the world. At the same time, spinoff from, and applications of, accelerators and accelerator technology are becoming increasingly important. Centrestage is now CERN's LHC proton-proton collider, where a test string of superconducting magnets is operating over long periods at the nominal LHC field of 8.36 tesla or more. The assignment of the underground areas in the existing 27- kilometre LEP tunnel is now quasidefinitive (see page 3). For CERN's existing big machine, the LEP electron-positron collider, ongoing work concentrates on boosting performance using improved optics and bunch trains. But the main objective is the LEP2 scheme using superconducting accelerating cavities to boost the beam energy (see page 6). After some initial teething problems, production and operation of these cavities appears to have been mastered, at least under test conditions. A highlight at CERN last year was the first run with lead ions (December 1994, page 15). Handling these heavy particles with systems originally designed for protons calls for ingenuity. The SPS

  10. Accelerator update

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-09-15

    When the Accelerator Conference, combined International High Energy and US Particle versions, held in Dallas in May, was initially scheduled, progress nearby for the US Superconducting Supercollider was high on the preliminary agenda. With the SSC voted down by Congress in October 1993, this was no longer the case. However the content of the meeting, in terms of both its deep implications for ambitious new projects and the breadth of its scope, showed that the worldwide particle accelerator field is far from being moribund. A traditional feature of such accelerator conferences is the multiplicity of parallel sessions. No one person can attend all sessions, so that delegates can follow completely different paths and emerge with totally different impressions. Despite this overload, and despite the SSC cancellation, the general picture is one of encouraging progress over a wide range of major new projects throughout the world. At the same time, spinoff from, and applications of, accelerators and accelerator technology are becoming increasingly important. Centrestage is now CERN's LHC proton-proton collider, where a test string of superconducting magnets is operating over long periods at the nominal LHC field of 8.36 tesla or more. The assignment of the underground areas in the existing 27- kilometre LEP tunnel is now quasidefinitive (see page 3). For CERN's existing big machine, the LEP electron-positron collider, ongoing work concentrates on boosting performance using improved optics and bunch trains. But the main objective is the LEP2 scheme using superconducting accelerating cavities to boost the beam energy (see page 6). After some initial teething problems, production and operation of these cavities appears to have been mastered, at least under test conditions. A highlight at CERN last year was the first run with lead ions (December 1994, page 15). Handling these heavy particles with systems originally designed for protons calls for ingenuity. The SPS has managed

  11. Bleeding and infection with external ventricular drainage: a systematic review in comparison with adjudicated adverse events in the ongoing Clot Lysis Evaluating Accelerated Resolution of Intraventricular Hemorrhage Phase III (CLEAR-III IHV) trial.

    Science.gov (United States)

    Dey, Mahua; Stadnik, Agnieszka; Riad, Fady; Zhang, Lingjiao; McBee, Nichol; Kase, Carlos; Carhuapoma, J Ricardo; Ram, Malathi; Lane, Karen; Ostapkovich, Noeleen; Aldrich, Francois; Aldrich, Charlene; Jallo, Jack; Butcher, Ken; Snider, Ryan; Hanley, Daniel; Ziai, Wendy; Awad, Issam A

    2015-03-01

    Retrospective series report varied rates of bleeding and infection with external ventricular drainage (EVD). There have been no prospective studies of these risks with systematic surveillance, threshold definitions, or independent adjudication. To analyze the rate of complications in the ongoing Clot Lysis: Evaluating Accelerated Resolution of Intraventricular Hemorrhage Phase III (CLEAR III) trial, providing a comparison with a systematic review of complications of EVD in the literature. Patients were prospectively enrolled in the CLEAR III trial after placement of an EVD for obstructive intraventricular hemorrhage and randomized to receive recombinant tissue-type plasminogen activator or placebo. We counted any detected new hemorrhage (catheter tract hemorrhage or any other distant hemorrhage) on computed tomography scan within 30 days from the randomization. Meta-analysis of published series of EVD placement was compiled with STATA software. Growing or unstable hemorrhage was reported as a cause of exclusion from the trial in 74 of 5707 cases (1.3%) screened for CLEAR III. The first 250 patients enrolled have completed adjudication of adverse events. Forty-two subjects (16.8%) experienced ≥1 new bleeds or expansions, and 6 of 250 subjects (2.4%) suffered symptomatic hemorrhages. Eleven cases (4.4%) had culture-proven bacterial meningitis or ventriculitis. Risks of bleeding and infection in the ongoing CLEAR III trial are comparable to those previously reported in EVD case series. In the present study, rates of new bleeds and bacterial meningitis/ventriculitis are very low despite multiple daily injections, blood in the ventricles, the use of thrombolysis in half the cases, and generalization to >60 trial sites.

  12. Phase II trial of combined surgical resection, high dose rate intraoperative radiation therapy, and external beam radiotherapy for malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Raben, A.; Rusch, V.; Mychalczak, B.; Ginsberg, R.; Burt, M.; Bains, M.; Francois, Damien; Harrison, L.B.

    1997-01-01

    Purpose: To determine the feasibility of combining extrapleural pneumonectomy (EPP) or pleurectomy / decortication (PD), high dose rate intraoperative radiation therapy (HDR-IORT) and postoperative external beam radiation hemithoracic radiation (EBHRT) to treat malignant pleural mesothelioma (MPM). Materials and Methods: From 3/94 through 9/94, 15 patients (pts) were enrolled on this trial. This included 3 females and 12 males with a median age of 59 (Range: 45-75). Eligibility criteria included biopsy proven MPM, no evidence of T4 or N3 disease by exam/CT/MRI, no evidence of metastatic disease, no previous treatment, and a Karnofsky performance status of ≥ 80%. Pts with pulmonary function tests permitting EPP, underwent EPP and HDR-IORT (N=7). The rest underwent PD/HDR-IORT (N=4). An intraoperative dose of 15 Gy was prescribed to a depth of 5 mm in tissue to the ipsilateral mediastinum, diaphragm, and chest wall. Postoperatively, 54 Gy of EBHRT was prescribed to the hemithorax, surgical scar and surgical drain site. The median surgical procedure time, median IORT time and median overall operating time was 554 minutes, 240 minutes, and 649 minutes respectively. The median dose of EBHRT was 50.4 Gy (Range 50-54 Gy). The median follow-up time is 8 months (Range: 3.5 to 28 months). Four of 15 pts had unresectable disease at the time of surgery and were taken off study. Results are presented in crude and actuarial analysis. Results: A complete resection of all visible gross disease was accomplished in 10 pts. One pt had a single focus of gross residual disease (less than 5 mm in size) left behind in the chest wall. The overall complication rate was 54%. Treatment related mortality occurred in 2 pts (18%) at 1 and 7 months respectively. This was attributed to ARDS in 1 pt (EPP/HDR-IORT) and radiation pneumonitis combined with a tracheoesophageal fistula in 1 pt (PD/HDR-IORT). Of the 6 remaining pts undergoing EPP/HDR-IORT, 2 pts developed a postoperative empyema with

  13. Can Accelerators Accelerate Learning?

    International Nuclear Information System (INIS)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-01-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ)[1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  14. Can Accelerators Accelerate Learning?

    Science.gov (United States)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-03-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ) [1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  15. Theory of Reasoned Action and the role of external factors in organic food purchase

    OpenAIRE

    Myresten, Emma; Setterhall, Mikaela

    2015-01-01

    This study examines a current phenomenon and behavioural shift amongst consumers’, namely the accelerating growth of organic food sales in Sweden. By combining the Theory of Reasoned Action (TRA), with the logic of value co-creation, an appropriate research tool has been developed stemmed from two related sub-studies. Based on TRA’s argument that additional factors, referred to as external, only can influence behavioural intention indirectly, combined with the proposed impact of value co-crea...

  16. Accelerators for energy

    International Nuclear Information System (INIS)

    Inoue, Makoto

    2000-01-01

    A particle accelerator is a device to consume energy but not to produce it. Then, the titled accelerator seems to mean an accelerator for using devices related to nuclear energy. For an accelerator combined to nuclear fissionable fuel, neutron sources are D-T type, (gamma, n) reaction using electron beam type spallation type, and so forth. At viewpoints of powers of incident beam and formed neutron, a spallation type source using high energy proton is told to be effective but others have some advantages by investigation on easy operability, easy construction, combustion with target, energy and directivity of neutron, and so forth. Here were discussed on an accelerator for research on accelerator driven energy system by dividing its researching steps, and on kind, energy, beam intensity, and so forth of an accelerator suitable for it. And, space electric charge effect at beam propagation direction controlled by beam intensity of cyclotron was also commented. (G.K.)

  17. Determination of the length and position of the lower oesophageal sphincter (LOS) by correlation of external measurements with combined radiographic and manometric estimations in the cat

    International Nuclear Information System (INIS)

    Hashim, M.A.; Waterman, A.E.

    1992-01-01

    Fifty DSH cats were studied radiographically and a highly significant linear correlation was found between the length of the oesophagus measured to the diaphragmatic line on the radiographs and the externally measured distance from the lower jaw incisor teeth to the anterior border of the head of 10th rib. A subsequent manometric study utilizing this correlation in 40 cats suggests that the functional lower oesophageal sphincter (LOS) is situated almost at the level of the diaphragm in the cat. Significant differences were found between the length of the LOS in cats anaesthetized with ketamine compared to alphaxalone-alphadolone or xylazine-ketamine-atropine. The mean lengths of the LOS was 1.42 +/- 0.3 cm. The findings of this study indicate that external measurements can be used to position catheters for accurate oesophageal manometry in the cat

  18. Combination of Open Subtotal Calcanectomy and Stabilization With External Fixation as Limb Salvage Procedure in Hindfoot-Infected Diabetic Foot Ulcers.

    Science.gov (United States)

    Dalla Paola, Luca; Carone, Anna; Boscarino, Giulio; Scavone, Giuseppe; Vasilache, Lucian

    2016-12-01

    Diabetic hindfoot ulcers, complicated by osteomyelitis, are associated with a high risk of major amputation. Partial calcanectomy, preceded by an effective management of the infection and of the eventual peripheral artery disease, can be considered as valid therapeutic option. We have evaluated a therapeutic protocol for diabetic hindfoot ulcers complicated by osteomyelitis, which, besides an adequate surgical debridement, considers a reconstructive pathway assisted by the positioning of a circular external fixator. We made a prospective study of a cohort of diabetic patients affected by heel ulcer complicated by osteomyelitis. All patients underwent open partial calcanectomy associated with the positioning of a circular external frame specifically designed for hindfoot stabilization and offloading. A reconstructive procedure was implemented starting with the application of negative pressure wound therapy and coverage with dermal substitute and split thickness skin grafting. From November 2014 to November 2015, 18 consecutive patients were enrolled. Mean follow-up period was 212.3 ± 64.0 days. Healing was achieved in 18 (100%) patients. The mean healing time was 69.0 ± 64.0 days. No major amputation had to be performed during the follow-up. Open partial calcanectomy associated with external fixation and skin reconstruction was as efficient as limb salvage in patients with infected lesions of the hindfoot complicated by calcaneal osteomyelitis.

  19. Plasma accelerators

    International Nuclear Information System (INIS)

    Bingham, R.; Angelis, U. de; Johnston, T.W.

    1991-01-01

    Recently attention has focused on charged particle acceleration in a plasma by a fast, large amplitude, longitudinal electron plasma wave. The plasma beat wave and plasma wakefield accelerators are two efficient ways of producing ultra-high accelerating gradients. Starting with the plasma beat wave accelerator (PBWA) and laser wakefield accelerator (LWFA) schemes and the plasma wakefield accelerator (PWFA) steady progress has been made in theory, simulations and experiments. Computations are presented for the study of LWFA. (author)

  20. Linear Accelerators

    International Nuclear Information System (INIS)

    Vretenar, M

    2014-01-01

    The main features of radio-frequency linear accelerators are introduced, reviewing the different types of accelerating structures and presenting the main characteristics aspects of linac beam dynamics

  1. [Case-control study on effects of external fixation combined with limited internal fixation for the treatment of Pilon fractures of Rüedi-Allgower type III].

    Science.gov (United States)

    Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng

    2014-01-01

    To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (Pexternal fixation with limited internal fixation in the treatment of Pilon fracture

  2. General purpose programmable accelerator board

    Science.gov (United States)

    Robertson, Perry J.; Witzke, Edward L.

    2001-01-01

    A general purpose accelerator board and acceleration method comprising use of: one or more programmable logic devices; a plurality of memory blocks; bus interface for communicating data between the memory blocks and devices external to the board; and dynamic programming capabilities for providing logic to the programmable logic device to be executed on data in the memory blocks.

  3. Accelerator Service

    International Nuclear Information System (INIS)

    Champelovier, Y.; Ferrari, M.; Gardon, A.; Hadinger, G.; Martin, J.; Plantier, A.

    1998-01-01

    Since the cessation of the operation of hydrogen cluster accelerator in July 1996, four electrostatic accelerators were in operation and used by the peri-nuclear teams working in multidisciplinary collaborations. These are the 4 MV Van de Graaff accelerator, 2,5 MV Van de Graaff accelerator, 400 kV ion implanter as well as the 120 kV isotope separator

  4. Ionization front accelerator

    International Nuclear Information System (INIS)

    Olson, C.L.

    1975-01-01

    In a recently proposed linear collective accelerator, ions are accelerated in a steep, moving potential well created at the head of an intense relativistic electron beam. The steepness of the potential well and its motion are controlled by the external ionization of a suitable background gas. Calculations concerning optimum choices for the background gas and the ionization method are presented; a two-step photoionization process employing Cs vapor is proposed. In this process, a super-radiant light source is used to excite the gas, and a UV laser is used to photoionize the excited state. The appropriate line widths and coupled ionization growth rate equations are discussed. Parameter estimates are given for a feasibility experiment, for a 1 GeV proton accelerator, and for a heavy ion accelerator (50 MeV/nucleon uranium). (auth)

  5. Combined Carbohydrate and Protein Ingestion During Australian Rules Football Matches and Training Sessions Does Not Reduce Fatigue or Accelerate Recovery Throughout a Weeklong Junior Tournament.

    Science.gov (United States)

    Lee, Nathan A; Fell, James W; Pitchford, Nathan W; Hall, Andrew H; Leveritt, Michael D; Kitic, Cecilia M

    2018-02-01

    Lee, NA, Fell, JW, Pitchford, NW, Hall, AH, Leveritt, MD, and Kitic, CM. Combined carbohydrate and protein ingestion during Australian rules football matches and training sessions does not reduce fatigue or accelerate recovery throughout a weeklong junior tournament. J Strength Cond Res 32(2): 344-355, 2018-Australian rules football (ARF) is a physically demanding sport that can induce high levels of fatigue. Fatigue may be intensified during periods where multiple matches are played with limited recovery time. Combined carbohydrate and protein (CHO + PRO) intake during physical activity may provide performance and recovery benefits. The aim of this study was to investigate whether CHO + PRO ingestion during ARF matches and training sessions throughout a tournament would enhance performance or recovery in comparison with CHO-only ingestion. Australian rules football players (n = 21) competing in a 7-day national tournament participated in this randomized and double-blinded study. Beverages containing either CHO (n = 10) or CHO + PRO (n = 11) were provided during matches (day 1, day 4, and day 7) and training sessions (day 2 and day 3). Countermovement jumps (CMJs), ratings of muscle soreness, and autonomic function were assessed throughout the tournament. Gastrointestinal tract (GI) discomfort was measured after matches. Countermovement jump peak velocity increased in the CHO + PRO group (p = 0.01) but not in the CHO group. There were no differences in the other CMJ variables. In both groups, muscle soreness increased from days 0 and 1 to day 2 (p ≤ 0.05) but did not remain elevated. R-R intervals (time elapsed between successive peaks in QRS complexes) increased in both groups from day 1 to day 7 (mean difference = 59.85 ms, p 0.05) between groups. When daily dietary protein is adequate (>1.8 g·kg·d), the ingestion of CHO + PRO during matches and training sessions throughout a tournament does not reduce muscle soreness nor have clear benefits for neuromuscular

  6. Modelling energy savings in the Danish building sector combined with internalisation of health related externalities in a heat and power system optimisation model

    DEFF Research Database (Denmark)

    Zvingilaite, Erika

    2013-01-01

    . Furthermore, the results suggest that changes in the energy generation sector are the prime driver behind the reduction of environmental externalities of energy. Heat savings in buildings play only a small role under model assumptions. © 2012Elsevier Ltd. All rights reserved.......A substantial untapped energy saving potential rests in the building sector and is expected to play an important role in achieving reduction of environmental impacts of energy. In order to utilise this potential, effective policy measures need to be adopted to remove the existing barriers...... and create incentives. For that purpose, the cost effective energy saving options together with an optimal level of savings and expected environmental benefits have to be identified. The paper reports on a study that analyses these questions by including heat-saving measures in buildings into an energy...

  7. Electrostatic Spectrograph with a Wide Range of Simultaneously Recorded Energies Composed of Two Coaxial Electrodes with Closed End Faces and a Discrete Combined External Electrode

    Science.gov (United States)

    Fishkova, T. Ya.

    2018-01-01

    An optimal set of geometric and electrical parameters of a high-aperture electrostatic charged-particle spectrograph with a range of simultaneously recorded energies of E/ E min = 1-50 has been found by computer simulation, which is especially important for the energy analysis of charged particles during fast processes in various materials. The spectrograph consists of two coaxial electrodes with end faces closed by flat electrodes. The external electrode with a conical-cylindrical form is cut into parts with potentials that increase linearly, except for the last cylindrical part, which is electrically connected to the rear end electrode. The internal cylindrical electrode and the front end electrode are grounded. In the entire energy range, the system is sharply focused on the internal cylindrical electrode, which provides an energy resolution of no worse than 3 × 10-3.

  8. Tracheal cancer treated with a short course of external and endoluminal radio-chemotherapy combined with cetuximab – a case report

    Directory of Open Access Journals (Sweden)

    Michael I. Koukourakis

    2010-01-01

    Full Text Available Primary tumors of the trachea are rare. Such cases are presented with acute respiratory distress demanding immediate therapeutic intervention. Herein, we present a case of an unresectable second primary tracheal cancer treated with intraluminal brachytherapy (8 Gy at 1 cm from catheter followed by a short course of external beam hypofractionated radiotherapy (4.5 Gy × 4 fractions and a final brachytherapy fraction (8 Gy, delivering a biological dose higher than 57.5 Gy (for α/β = 4 Gy to the tumor within 4 weeks. Concurrent chemotherapy consisted of: fluoruracil (1000 mg/m2,leucovorin (100 mg/m2, oxaliplatin (80 mg/m2 and cetuximab (500 mg/m2, administered every two weeks for two consecutive cycles. Complete response was evident during the second brachytherapy fraction and the patient is alive with no evidence of disease, two years after therapy, without any late radiation sequel.

  9. Recent progress in particle accelerators

    International Nuclear Information System (INIS)

    Cole, F.T.; Mills, F.E.

    1988-01-01

    Many accelerators have also been built for medical radiography and therapy. Electron accelerators for this application are available commercially, using the electrons directly or bremsstrahlung photons. Neutrons produced by accelerator beams have also been used for therapy with considerable success, and several proton accelerators built for physics research have been adapted for direct therapy with protons. The first proton accelerator specifically for therapy is now being built. Separate from what might be called conventional accelerator technology, an entirely new field utilizing very highly pulsed power has been developed, and beams of short pulses of thousands or millions of amperes peak current in the MeV energy range are now available. These beams have important applications in high-energy particle acceleration, controlled fusion, industrial treatment of materials, and possibly in food preservation. All of these accelerators make use of external fields of acceleration. There is also vigorous research into new methods of acceleration, in many schemes making use of the intense accelerating fields, generated by laser beams or by plasma states of matter. This research has not as yet made traditional kinds of accelerators outmoded, but many workers hope that early in the next century there will be practical new acceleration methods making use of these very high fields. These developments are discussed in detail

  10. Electron injection and acceleration in the plasma bubble regime driven by an ultraintense laser pulse combined with using dense-plasma wall and block

    Science.gov (United States)

    Zhao, Xue-Yan; Xie, Bai-Song; Wu, Hai-Cheng; Zhang, Shan; Hong, Xue-Ren; Aimidula, Aimierding

    2012-03-01

    An optimizing and alternative scheme for electron injection and acceleration in the wake bubble driven by an ultraintense laser pulse is presented. In this scheme, the dense-plasma wall with an inner diameter matching the expected bubble size is placed along laser propagation direction. Meanwhile, a dense-plasma block dense-plasma is adhered inward transversely at some certain position of the wall. Particle-in-cell simulations are performed, which demonstrate that the block plays an important role in the first electron injection and acceleration. The result shows that a collimated electron bunch with a total number of about 4.04×108μm-1 can be generated and accelerated stably to 1.61 GeV peak energy with 2.6% energy spread. The block contributes about 50% to the accelerated electron injection bunch by tracing and sorting statistically the source.

  11. Experimental investigation of the accuracy for absolute quantification of brain creatine concentration using long time echo point resolved spectroscopy sequence with an external standard and linear combination of model spectra

    International Nuclear Information System (INIS)

    Lin Yan; Shen Zhiwei; Xiao Yeyu; Zheng Wenbin; Wu Renhua; Li Hui; Xiao Zhuanwei

    2008-01-01

    Objective: To investigate the accuracy for absolute quantification of brain creatine (Cr) concentration using long time echo (TE) point resolved spectroscopy (PRESS) sequence performed with an extemal standard and postprocessed with the linear combination of model spectra ( LCModel). Methods: Ten swine (3.1 ± 0.6 kg) and an external standard phantom containing detectable compounds of known concentration were investigated in this study by using 1.5 T GE Signa scanner and a standard head coil. The single-voxel proton magnetic resonance spectroscopy ( 1 H-MRS) data were acquired from the two ROIs (2 cm x 2 cm x 2 cm) placed in swine brain and external standard solution using PRESS sequence with TE 135 ms, TR 1500 ms, and 128 scan averages. The in vivo quantification of Cr was accomplished by LCModel. After 1 H-MRS examination, each animal was sacrificed immediately. In vitro Cr concentration was analyzed by high performance liquid chromatography (HPLC). Results: In the 1 H-MRS group, the Cr concentration was (9.37±0.14)mmol/kg. In the HPLC group, the Cr concentration was (8.91± 0.13)mmol/kg. Good agreement was obtained between these two methods (t=9.038, P=0.491). Conclusion: The long echo time PRESS sequence performed with an external standard and processed with LCModel is proven to be an accurate technique to detect the in vivo brain Cr concentration. (authors)

  12. Modelling energy savings in the Danish building sector combined with internalisation of health related externalities in a heat and power system optimisation model

    International Nuclear Information System (INIS)

    Zvingilaite, Erika

    2013-01-01

    A substantial untapped energy saving potential rests in the building sector and is expected to play an important role in achieving reduction of environmental impacts of energy. In order to utilise this potential, effective policy measures need to be adopted to remove the existing barriers and create incentives. For that purpose, the cost effective energy saving options together with an optimal level of savings and expected environmental benefits have to be identified. The paper reports on a study that analyses these questions by including heat-saving measures in buildings into an energy system optimisation model of the Danish heat and power sector. The achieved optimal level of heat savings reaches 11% of projected heat demand in 2025 under the model assumptions. Moreover, the analysis reveals the importance of considering energy conservation options in a system wide perspective. Furthermore, the results suggest that changes in the energy generation sector are the prime driver behind the reduction of environmental externalities of energy. Heat savings in buildings play only a small role under model assumptions. - Highlights: ► Heat savings in buildings are analysed together with a heat and power system. ► Heat savings compete with electricity to heat technologies, mainly heat pumps. ► Cost effective heat-savings bring small decrease in health impacts and CO 2 emissions. ► Cost-effectiveness of heat savings depends on the marginal heat generation technology

  13. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    Directory of Open Access Journals (Sweden)

    Zacharia Facaros

    2010-10-01

    Full Text Available The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This technique may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss.

  14. Future accelerators (?)

    Energy Technology Data Exchange (ETDEWEB)

    John Womersley

    2003-08-21

    I describe the future accelerator facilities that are currently foreseen for electroweak scale physics, neutrino physics, and nuclear structure. I will explore the physics justification for these machines, and suggest how the case for future accelerators can be made.

  15. Local control and survival in patients with soft tissue sarcomas treated with limb sparing surgery in combination with interstitial brachytherapy and external radiation

    DEFF Research Database (Denmark)

    Muhic, A.; Hovgaard, D.; Mork, Petersen M.

    2008-01-01

    %. Nineteen (49%) patients suffered from some degree of decreased force or function of the affected extremity, 16 (41%) suffered from oedema, 12 (31%) had persistent pain, 8 (21%) suffered from wound complications, and in 4 (10%) of these patients plastic surgery were required. CONCLUSION: Limb sparing...... surgery, combined with PDR BRT and EBRT can result in good local control in patients with soft tissue sarcomas. BRT is an effective modality with good cosmetic results and acceptable toxicity Udgivelsesdato: 2008/9...

  16. Long-Term Results of an RTOG Phase II Trial (00-19) of External-Beam Radiation Therapy Combined With Permanent Source Brachytherapy for Intermediate-Risk Clinically Localized Adenocarcinoma of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, Colleen A., E-mail: clawton@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Yan, Yan [Radiation Therapy Oncology Group Statistical Center, Philadelphia, PA (United States); Lee, W. Robert [Department of Radiation Oncology, Duke University School of Medicine, Durham, NC (United States); Gillin, Michael [Department of Radiation Oncology, MD Anderson Cancer Center, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Firat, Selim [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Baikadi, Madhava [Department of Radiation Oncology, Northeast Radiation Oncology Center, Scranton, PA (United States); Crook, Juanita [Department of Radiation Oncology, University of British Columbia, Kelowna, BC (Canada); Kuettel, Michael [Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, NY (United States); Morton, Gerald [Department of Radiation Oncology, Toronto-Sunnybrook Regional Cancer Center, Toronto, ON (Canada); Sandler, Howard [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2012-04-01

    Purpose: External-beam radiation therapy combined with low-doserate permanent brachytherapy are commonly used to treat men with localized prostate cancer. This Phase II trial was performed to document late gastrointestinal or genitourinary toxicity as well as biochemical control for this treatment in a multi-institutional cooperative group setting. This report defines the long-term results of this trial. Methods and Materials: All eligible patients received external-beam radiation (45 Gy in 25 fractions) followed 2-6 weeks later by a permanent iodine 125 implant of 108 Gy. Late toxicity was defined by the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring scheme. Biochemical control was defined by the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus definition and the ASTRO Phoenix definition. Results: One hundred thirty-eight patients were enrolled from 20 institutions, and 131 were eligible. Median follow-up (living patients) was 8.2 years (range, 2.7-9.3 years). The 8-year estimate of late grade >3 genitourinary and/or gastrointestinal toxicity was 15%. The most common grade >3 toxicities were urinary frequency, dysuria, and proctitis. There were two grade 4 toxicities, both bladder necrosis, and no grade 5 toxicities. In addition, 42% of patients complained of grade 3 impotence (no erections) at 8 years. The 8-year estimate of biochemical failure was 18% and 21% by the Phoenix and ASTRO consensus definitions, respectively. Conclusion: Biochemical control for this treatment seems durable with 8 years of follow-up and is similar to high-dose external beam radiation alone or brachytherapy alone. Late toxicity in this multi-institutional trial is higher than reports from similar cohorts of patients treated with high-dose external-beam radiation alone or permanent low-doserate brachytherapy alone, perhaps suggesting further attention to strategies that limit doses to

  17. High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

    International Nuclear Information System (INIS)

    Sato, Morio; Mori, Takashi; Shirai, Shintaro; Kishi, Kazushi; Inagaki, Takeshi; Hara, Isao

    2008-01-01

    Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings

  18. External noise when using biofuel

    International Nuclear Information System (INIS)

    Kotaleski, J.

    1994-08-01

    The aim of this study has been to cover sources of noise dealing with all steps in a biofuel chain; producing, transporting, storing and firing the biofuel. When the availability of relevant test results from noise surveys is not so good and mostly badly documented, the study has been concentrated on estimation of external noise for planning and design purposes, from a prospective biofuel-fired plant. A synoptic tabulation of estimated acoustic power levels from different noise sources, has been done. The results from measurements of external noise from different existing combined power and heating plants are tabulated. The Nordic model for simulation of external noise has been used for a prospective plant - VEGA - designed by Vattenfall. The aim has been to estimate its noise pollutions at critical points at the nearest residential area (250 m from the fenced industry area). The software - ILYD - is easy to handle, but knowledge about the model is necessary. A requisite for the reliability is the access to measurements or estimations of different sources of noise, at different levels of octaves from 63 to 8000 Hz. The degree of accuracy increases with the number of broad band sources, that are integrated. Using ILYD with available data, a night limit of 40 dB(A) should be possible to fulfill with good degree of accuracy at VEGA, between 10 pm and 7 am, with good planning and under normal operation conditions. A demand for 35 dB(A) as a limit can be harder to fulfill, especially at mornings from 6 to 7. Noise from heavy vehicles within the plant area is classified as industrial noise and not as road traffic noise. This type of noise depends very much on the way of driving and assumed acceleration. Concerning wheel-mounted loaders, they may then only be used during daytime. The simulations show, that even at daytime from 7 to 6 pm, it would be possible to use an acoustically damped chipping machine, inside the power industry area. 31 refs, 13 figs, tabs, 8

  19. A combined accelerator mass spectrometry-positron emission tomography human microdose study with 14C- and 11C-labelled verapamil.

    Science.gov (United States)

    Wagner, Claudia C; Simpson, Marie; Zeitlinger, Markus; Bauer, Martin; Karch, Rudolf; Abrahim, Aiman; Feurstein, Thomas; Schütz, Matthias; Kletter, Kurt; Müller, Markus; Lappin, Graham; Langer, Oliver

    2011-02-01

    In microdose studies, the pharmacokinetic profile of a drug in blood after administration of a dose up to 100 μg is measured with sensitive analytical techniques, such as accelerator mass spectrometry (AMS). As most drugs exert their effect in tissue rather than blood, methodology is needed for extending pharmacokinetic analysis to different tissue compartments. In the present study, we combined, for the first time, AMS analysis with positron emission tomography (PET) in order to determine the pharmacokinetic profile of the model drug verapamil in plasma and brain of humans. In order to assess pharmacokinetic dose linearity of verapamil, data were acquired and compared after administration of an intravenous microdose and after an intravenous microdose administered concomitantly with an oral therapeutic dose. Six healthy male subjects received an intravenous microdose [0.05 mg] (period 1) and an intravenous microdose administered concomitantly with an oral therapeutic dose [80 mg] of verapamil (period 2) in a randomized, crossover, two-period study design. The intravenous dose was a mixture of (R/S)-[14C]verapamil and (R)-[11C]verapamil and the oral dose was unlabelled racaemic verapamil. Brain distribution of radioactivity was measured with PET whereas plasma pharmacokinetics of (R)- and (S)-verapamil were determined with AMS. PET data were analysed by pharmacokinetic modelling to estimate the rate constants for transfer (k) of radioactivity across the blood-brain barrier. Most pharmacokinetic parameters of (R)- and (S)-verapamil as well as parameters describing exchange of radioactivity between plasma and brain (influx rate constant [K(1)] = 0.030 ± 0.003 and 0.031 ± 0.005 mL/mL/min and efflux rate constant [k(2)] = 0.099 ± 0.006 and 0.095 ± 0.008 min-1 for period 1 and 2, respectively) were not statistically different between the two periods although there was a trend for nonlinear pharmacokinetics for the (R)-enantiomer. On the other hand, all

  20. Aggressive simultaneous radiochemotherapy with cisplatin and paclitaxel in combination with accelerated hyperfractionated radiotherapy in locally advanced head and neck tumors. Results of a phase I-II trial

    Energy Technology Data Exchange (ETDEWEB)

    Kuhnt, T.; Pigorsch, S.; Pelz, T.; Haensgen, G.; Dunst, J. [Dept. of Radiotherapy, Martin Luther Univ., Halle (Germany); Becker, A. [Dept. of Radiotherapy, Martin Luther Univ., Halle (Germany); Dept. of Radiotherapy, Municipial Hospital, Dessau (Germany); Bloching, M.; Passmann, M. [Dept. of Head and Neck Surgery, Martin Luther Univ., Halle (Germany); Lotterer, E. [Dept. of Internal Medicine I, Martin Luther Univ., Halle (Germany)

    2003-10-01

    We have tested a very aggressive combination protocol with cisplatin and escalated paclitaxel in combination with accelerated hyperfractionated radiotherapy to assess the maximum tolerated dose (MTD), dose-limiting toxicity (DLT), overall toxicity, and response rate. Patients and Methods: The trial recruited 24 patients (21 males, three females, mean age 57 years) treated at our department from 1998 through 2001. Irradiation was administered in daily doses of 2 Gy up to 30 Gy followed by 1.4 Gy twice daily up to 70.6 Gy to the primary tumor and involved nodes and 51 Gy to the clinically negative regional nodes. The chemotherapy schedule included cisplatin in a fixed dose of 20 mg/m{sup 2} on days 1-5 and 29-33 and paclitaxel at increasing dose levels of 20, 25, 30 mg/m{sup 2} twice weekly over the whole treatment time. Patients were recruited in cohorts of three to six, and the MTD was reached if two out of six patients in one cohort developed DLT. DLT was defined as any grade 4 toxicity or any grade 3 toxicity requiring treatment interruption or unplanned hospitalization or any grade 3 neurotoxicity. We recruited mainly patients with large tumors for this protocol; all patients were stage IV, and the mean tumor volume (primary + metastases) amounted to 72 {+-} 61 cm{sup 3}. The mean follow-up was 30 months (range 4-39 months). Results: One early death (peritonitis and sepsis a t day 10) occurred, and 23 patients were evaluable for acute toxicity and response. The MTD of paclitaxel was reached at the third dose level (30 mg/m{sup 2} paclitaxel twice weekly). The DLT was severe mucositis grade 3 (n = 1) and skin erythema grade 4 (n = 2). After determining the MTD, another 14 patients were treated at the recommended dose level of paclitaxel with 25 mg/m{sup 2} twice weekly. In summary, 13/23 patients (57%) developed grade 3 and 10/23 (43%) grade 2 mucositis. Two patients (9%) had grade 4, five (22%) grade 3, and 16 (69%) grade 2 dermatitis. One patient died at day 30

  1. Aggressive simultaneous radiochemotherapy with cisplatin and paclitaxel in combination with accelerated hyperfractionated radiotherapy in locally advanced head and neck tumors. Results of a phase I-II trial

    International Nuclear Information System (INIS)

    Kuhnt, T.; Pigorsch, S.; Pelz, T.; Haensgen, G.; Dunst, J.; Becker, A.; Bloching, M.; Passmann, M.; Lotterer, E.

    2003-01-01

    We have tested a very aggressive combination protocol with cisplatin and escalated paclitaxel in combination with accelerated hyperfractionated radiotherapy to assess the maximum tolerated dose (MTD), dose-limiting toxicity (DLT), overall toxicity, and response rate. Patients and Methods: The trial recruited 24 patients (21 males, three females, mean age 57 years) treated at our department from 1998 through 2001. Irradiation was administered in daily doses of 2 Gy up to 30 Gy followed by 1.4 Gy twice daily up to 70.6 Gy to the primary tumor and involved nodes and 51 Gy to the clinically negative regional nodes. The chemotherapy schedule included cisplatin in a fixed dose of 20 mg/m 2 on days 1-5 and 29-33 and paclitaxel at increasing dose levels of 20, 25, 30 mg/m 2 twice weekly over the whole treatment time. Patients were recruited in cohorts of three to six, and the MTD was reached if two out of six patients in one cohort developed DLT. DLT was defined as any grade 4 toxicity or any grade 3 toxicity requiring treatment interruption or unplanned hospitalization or any grade 3 neurotoxicity. We recruited mainly patients with large tumors for this protocol; all patients were stage IV, and the mean tumor volume (primary + metastases) amounted to 72 ± 61 cm 3 . The mean follow-up was 30 months (range 4-39 months). Results: One early death (peritonitis and sepsis a t day 10) occurred, and 23 patients were evaluable for acute toxicity and response. The MTD of paclitaxel was reached at the third dose level (30 mg/m 2 paclitaxel twice weekly). The DLT was severe mucositis grade 3 (n = 1) and skin erythema grade 4 (n = 2). After determining the MTD, another 14 patients were treated at the recommended dose level of paclitaxel with 25 mg/m 2 twice weekly. In summary, 13/23 patients (57%) developed grade 3 and 10/23 (43%) grade 2 mucositis. Two patients (9%) had grade 4, five (22%) grade 3, and 16 (69%) grade 2 dermatitis. One patient died at day 30 of neutropenic infection

  2. [Case control study on therapeutic effects of dynamic external fixtor combined with limited internal fixation and cross K-wires fixation for the treatment of Pilon fractures of the proximal interphalangeal joint].

    Science.gov (United States)

    Miao, Dao-yi; Yang, Guo-jing; Zhang, Ling-zhou; Wu, Jian-wei

    2015-10-01

    To compare the clinical effects and safety of dynamic external fixtor combined with limited internal fixation and cross K-wires fixation for the treatment of close Pilon fractures of the proximal interphalangeal joint. From June 2012 to June 2014, totally 41 patients (45 fingers) with close interphalangeal joint Pilon fracture were treated by dynamic external fixtor combined with limited internal fixation or cross K-wires fixation, and all the patients were followed up. In the dynamic external fixtor combined with limited internal fixation group (group A), there were 21 patients with 22 fingers, including 12 males and 9 females, with an average of (30.6±5.6) years old. In the cross K-wires fixation group (group B), there were 20 patients with 23 fingers, including 11 males and 9 females, with an average of (30.1±5.3) years old. Regular re-examination of X-ray was performed to evaluate the active range of joint motion, fracture healing time, infection rate and postoperative joint motion pain. According to the evaluation criteria of upper extremity function issued by the Hand Surgery Society of Chinese Medical Association, the excellent and good cases of group A was up to 19 and 13 for group B. The evaluation results has significant differences (Z=2.558, P=0.011). The excellent and good rate of group A was obviously higher than that of group B. The average bone union time of group A was (7.9±2.1) weeks, and (8.1±2.3) weeks for group B. There was no significant difference on the mean healing time (t=-0.304, P=0.762). The infection fingers of group A was 5, and 1 for group B. The difference between the results was statistically significant (χ2=3.287, Pexternal fixtor combined with limited internal fixation is a reliable and effective method to treat Pilon fractures of the proximal interphalangeal joint. It allows early postoperative functional rehabilitation and restores the joint function.

  3. Monocyte galactose/N-acetylgalactosamine-specific C-type lectin receptor stimulant immunotherapy of an experimental glioma. Part II: combination with external radiation improves survival

    Directory of Open Access Journals (Sweden)

    Kushchayev SV

    2012-09-01

    Full Text Available Sergiy V Kushchayev,1 Tejas Sankar,1 Laura L Eggink,5,6 Yevgeniya S Kushchayeva,5 Philip C Wiener,1,5 J Kenneth Hoober,5,6 Jennifer Eschbacher,3 Ruolan Liu,2 Fu-Dong Shi,2 Mohammed G Abdelwahab,4 Adrienne C Scheck,4 Mark C Preul11Neurosurgery Research Laboratory, 2Neuroimmunology Laboratory, 3Department of Pathology, 4Neurooncology Research, Barrow Neurological Institute, St Joseph's Hospital and Medical Center, Phoenix, 5School of Life Sciences, Arizona State University, Tempe, 6Susavion Biosciences, Inc, Tempe, AZ, USABackground: A peptide mimetic of a ligand for the galactose/N-acetylgalactosamine-specific C-type lectin receptors (GCLR exhibited monocyte-stimulating activity, but did not extend survival when applied alone against a syngeneic murine malignant glioma. In this study, the combined effect of GCLRP with radiation was investigated.Methods: C57BL/6 mice underwent stereotactic intracranial implantation of GL261 glioma cells. Animals were grouped based on randomized tumor size by magnetic resonance imaging on day seven. One group that received cranial radiation (4 Gy on days seven and nine only were compared with animals treated with radiation and GCLRP (4 Gy on days seven and nine combined with subcutaneous injection of 1 nmol/g on alternative days beginning on day seven. Magnetic resonance imaging was used to assess tumor growth and correlated with survival rate. Blood and brain tissues were analyzed with regard to tumor and contralateral hemisphere using fluorescence-activated cell sorting analysis, histology, and enzyme-linked immunosorbent assay.Results: GCLRP activated peripheral monocytes and was associated with increased blood precursors of dendritic cells. Mean survival increased (P < 0.001 and tumor size was smaller (P < 0.02 in the GCLRP + radiation group compared to the radiation-only group. Accumulation of dendritic cells in both the tumoral hemisphere (P < 0.005 and contralateral tumor-free hemisphere (P< 0.01 was

  4. Investigation of carbohydrate and protein metabolism in the digestive organs of the rabbit under the combined influence of vibration, acceleration and irradiation

    Science.gov (United States)

    Yuy, R. I.

    1975-01-01

    During spaceflight, the organism is subjected to the influence of various extremal factors such as acceleration, vibration, irradiation, etc. The study of the influence of these factors on metabolism, especially carbohydrate and protein metabolism, in young rabbits is of great significance in simulation experiments. Dynamic factors and irradiation, depending on dose and duration, lead to reduced RNA and protein metabolism.

  5. Auroral electron acceleration

    International Nuclear Information System (INIS)

    Bryant, D.A.

    1989-10-01

    Two theories of auroral electron acceleration are discussed. Part 1 examines the currently widely held view that the acceleration is an ordered process in a quasi-static electric field. It is suggested that, although there are many factors seeming to support this theory, the major qualifications and uncertainties that have been identified combine to cast serious doubt over its validity. Part 2 is devoted to a relatively new interpretation in terms of stochastic acceleration in turbulent electric fields. This second theory, which appears to account readily for most known features of the electron distribution function, is considered to provide a more promising approach to this central question in magnetospheric plasma physics. (author)

  6. Long-Term Outcomes for Patients with Prostate Cancer Having Intermediate and High-Risk Disease, Treated with Combination External Beam Irradiation and Brachytherapy

    Directory of Open Access Journals (Sweden)

    Michael Dattoli

    2010-01-01

    Full Text Available Background. Perception remains that brachytherapy-based regimens are inappropriate for patients having increased risk of extracapsular extension (ECE. Methods. 321 consecutive intermediate and high-risk disease patients were treated between 1/92 and 2/97 by one author (M. Dattoli and stratified by NCCN guidelines. 157 had intermediate-risk; 164 had high-risk disease. All were treated using the combination EBRT/brachytherapy ± hormones. Biochemical failure was defined using PSA >0.2 and nadir +2 at last followup. Nonfailing patients followup was median 10.5 years. Both biochemical data and original biopsy slides were independently rereviewed at an outside institution. Results. Overall actuarial freedom from biochemical progression at 16 years was 82% (89% intermediate, 74% high-risk with failure predictors: Gleason score (=.01 and PSA (=.03. Hormonal therapy did not affect failure rates (=.14. Conclusion. This study helps to strengthen the rationale for brachytherapy-based regimens as being both durable and desirable treatment options for such patients. Prospective studies are justified to confirm these positive results.

  7. KEK digital accelerator

    Directory of Open Access Journals (Sweden)

    T. Iwashita

    2011-07-01

    Full Text Available The High Energy Accelerator Research Organization KEK digital accelerator (KEK-DA is a renovation of the KEK 500 MeV booster proton synchrotron, which was shut down in 2006. The existing 40 MeV drift tube linac and rf cavities have been replaced by an electron cyclotron resonance (ECR ion source embedded in a 200 kV high-voltage terminal and induction acceleration cells, respectively. A DA is, in principle, capable of accelerating any species of ion in all possible charge states. The KEK-DA is characterized by specific accelerator components such as a permanent magnet X-band ECR ion source, a low-energy transport line, an electrostatic injection kicker, an extraction septum magnet operated in air, combined-function main magnets, and an induction acceleration system. The induction acceleration method, integrating modern pulse power technology and state-of-art digital control, is crucial for the rapid-cycle KEK-DA. The key issues of beam dynamics associated with low-energy injection of heavy ions are beam loss caused by electron capture and stripping as results of the interaction with residual gas molecules and the closed orbit distortion resulting from relatively high remanent fields in the bending magnets. Attractive applications of this accelerator in materials and biological sciences are discussed.

  8. External-beam radiation therapy combined with limb-sparing surgery in elderly patients (>70 years) with primary soft tissue sarcomas of the extremities. A retrospective analysis

    Energy Technology Data Exchange (ETDEWEB)

    Andrae, Claudia; Rauch, Josefine; Belka, Claus [University Hospital of Munich (LMU), Department of Radiation Oncology, Munich (Germany); Klein, Alexander; Duerr, Hans Roland [University Hospital of Munich (LMU), Department of Orthopedics, Munich (Germany); Lindner, Lars Hartwin [University Hospital of Munich (LMU), Deparment of Internal Medicine, Munich (Germany); Knoesel, Thomas [University Hospital of Munich (LMU), Institute of Pathology, Munich (Germany); Angele, Martin [University Hospital of Munich (LMU), Department of Surgery, Munich (Germany); Baur-Melnyk, Andrea [University Hospital of Munich (LMU), Department of Radiology, Munich (Germany); Roeder, Falk [University Hospital of Munich (LMU), Department of Radiation Oncology, Munich (Germany); German Cancer Research Center (DKFZ), CCU Molecular Radiation Oncology, Heidelberg (Germany)

    2017-08-15

    To report our experience with EBRT combined with limb-sparing surgery in elderly patients (>70 years) with primary extremity soft tissue sarcomas (STS). Retrospectively analyzed were 35 patients (m:f 18:17, median 78 years) who all presented in primary situation without nodal/distant metastases (Charlson score 0/1 in 18 patients; ≥2 in 17 patients). Median tumor size was 10 cm, mainly located in lower limb (83%). Stage at presentation (UICC7th) was Ib:3%, 2a:20%, 2b:20%, and 3:57%. Most lesions were high grade (97%), predominantly leiomyosarcoma (26%) and undifferentiated pleomorphic/malignant fibrous histiocytoma (23%). Limb-sparing surgery was preceded (median 50 Gy) or followed (median 66 Gy) by EBRT. Median follow-up was 37 months (range 1-128 months). Margins were free in 26 patients (74%) and microscopically positive in 9 (26%). Actuarial 3- and 5-year local control rates were 88 and 81% (4 local recurrences). Corresponding rates for distant control, disease-specific survival, and overall survival were 57/52%, 76/60%, and 72/41%. The 30-day mortality was 0%. Severe postoperative complications were scored in 8 patients (23%). Severe acute radiation-related toxicity was observed in 2 patients (6%). Patients with Charlson score ≥2 had a significantly increased risk for severe postoperative complications and acute radiation-related side effects. Severe late toxicities were found in 7 patients (20%), including fractures in 3 (8.6%). Final limb preservation rate was 97%. Combination of EBRT and limb-sparing surgery is feasible in elderly patients with acceptable toxicities and encouraging but slightly inferior outcome compared to younger patients. Comorbidity correlated with postoperative complications and acute toxicities. Late fracture risk seems slightly increased. (orig.) [German] Erfahrungsbericht zur perkutanen Radiotherapie (EBRT) kombiniert mit extremitaetenerhaltender Operation bei Patienten >70 Jahre mit Weichteilsarkom der Extremitaet. Retrospektiv

  9. Health-related quality of life and treatment outcomes for men with prostate cancer treated by combined external-beam radiotherapy and hormone therapy

    International Nuclear Information System (INIS)

    Hashine, Katsuyoshi; Azuma, Kouji; Koizumi, Takahiro; Sumiyoshi, Yoshiteru

    2005-01-01

    Health-related quality of life (HR-QOL) is important when considering the treatment options for prostate cancer. From 1992 to 1998, 57 patients were treated by radiotherapy plus hormone therapy (median age, 79 years; median prostate-specific antigen concentration, 15.0 ng/ml; median radiotherapy dosage, 60 Gy). General HR-QOL was measured by the European Organization for Research and Treatment of Cancer Prostate Cancer QOL Questionnaire, and a newly developed disease-specific QOL survey was used to assess urinary and bowel functions. QOL was also measured in a control group of patients admitted for prostate biopsy. The general HR-QOL scores in the radiation group ranged from 70.0 to 91.3, with sexual problems showing the lowest (i.e., worst) score (38.5). Compared with the control group, the scores in the radiation group were worse for physical function and sexual problems. For disease-specific QOL, the radiation group had worse urinary function than controls, but were more satisfied with their urinary function. There was no difference between the radiation group and controls in satisfaction with bowel function. When the control group was subdivided at into two groups: age 75 years or less, and age over 75 years, the QOL score in the radiation group was the same as that in the subgroup aged over 75 years. In subgroups of the radiation patients, according to survey period, there was no difference between the first and last surveys in longitudinal HR-QOL evaluations. The 5- and 10-year overall survival rates were 67.6% and 41.6%, respectively, and the 5- and 10-year cause-specific survival rates were 97.9% and 94.7%. The combination of radiotherapy and hormone therapy has a good outcome and patients do not experience poor HR-QOL, except for sexual problems. Moreover, the disease-specific QOL is good, especially for urinary bother. (author)

  10. Combining coal gasification, natural gas reforming, and external carbonless heat for efficient production of gasoline and diesel with CO2 capture and sequestration

    International Nuclear Information System (INIS)

    Salkuyeh, Yaser Khojasteh; Adams, Thomas A.

    2013-01-01

    Highlights: • Several systems are presented which convert NG, coal, and carbonless heat to fuel. • Using nuclear heat can reduce the direct fossil fuel consumption by up to 22%. • The use of CCS depended on the carbon tax: above $20-30/t is sufficient to use CCS. • CTL is only the most economical when the price of NG is more than $5 /MMBtu. • Compared to a traditional CTL plant, total CO 2 emission can be reduced up to 79%. - Abstract: In this paper, several novel polygeneration systems are presented which convert natural gas, coal, and a carbonless heat source such as high-temperature helium to gasoline and diesel. The carbonless heat source drives a natural gas reforming reaction to produce hydrogen rich syngas, which is mixed with coal-derived syngas to produce a syngas blend ideal for the Fischer–Tropsch reaction. Simulations and techno-economic analyses performed for 16 different process configurations under a variety of market conditions indicate significant economic and environmental benefits. Using a combination of coal, gas, and carbonless heat, it is possible to reduce CO 2 emissions (both direct and indirect) by 79% compared to a traditional coal-to-liquids process, and even achieve nearly zero CO 2 emissions when carbon capture and sequestration technology is employed. Using a carbonless heat source, the direct fossil fuel consumption can be reduced up to 22% and achieve a carbon efficiency up to 72%. Market considerations for this analysis include prices of coal, gas, high-temperature helium, gasoline, and CO 2 emission tax rates. The results indicate that coal-only systems are never the most economical choice, unless natural gas is more than 5 $/MMBtu

  11. Vaginal dose point reporting in cervical cancer patients treated with combined 2D/3D external beam radiotherapy and 2D/3D brachytherapy

    International Nuclear Information System (INIS)

    Westerveld, Henrike; Pötter, Richard; Berger, Daniel; Dankulchai, Pittaya; Dörr, Wolfgang; Sora, Mircea-Constantin; Pötter-Lang, Sarah; Kirisits, Christian

    2013-01-01

    Background and purpose: Traditionally, vaginal dose points have been defined at the vaginal source level, thus not providing dose information for the entire vagina. Since reliable vaginal dose volume/surface histograms are unavailable, a strategy for comprehensive vaginal dose reporting for combined EBRT and BT was established and investigated. Material and methods: An anatomical vaginal reference point was defined at the level of the Posterior–Inferior Border of Symphysis (PIBS), plus two points ±2 cm (mid/introitus vagina). For BT extra points were selected for the upper vagina at 12/3/6/9 o’clock, at the vaginal surface and 5 mm depth. A vaginal reference length (VRL) was defined from ring centre to PIBS. Fifty-nine patients treated for cervical cancer were included in this retrospective feasibility study. Results: The method was applicable to all patients. Total EQD2 doses at PIBS and ±2 cm were 36.7 Gy (3.1–68.2), 49.6 Gy (32.1–89.6) and 4.3 Gy (1.0–46.6). At the vaginal surface at ring level doses were respectively 266.1 Gy (67.6–814.5)/225.9 Gy (61.5–610.5) at 3/9 o’clock, and 85.1 Gy (55.4–140.3)/72.0 Gy (49.1–108.9) at 12/6 o’clock. Mean VRL on MRI was 5.6 cm (2.0–9.4). Conclusions: With this novel system, a comprehensive reporting of vaginal doses is feasible. The present study has demonstrated large dose variations between patients observed in all parts of the vagina, resulting from different contributions from EBRT and BT

  12. Phase I clinical trial of parenteral hydroxyurea in combination with pelvic and para-aortic external radiation and brachytherapy for patients with advanced squamous cell cancer of the uterine cervix

    International Nuclear Information System (INIS)

    Beitler, Jonathan J.; Anderson, Patrick; Haynes, Hilda; Sood, Brij; Fields, Abbi; Goldberg, Gary; Vikram, Bhadrasain; Runowicz, Carolyn D.; Wadler, Scott

    2002-01-01

    Purpose: Oral hydroxyurea (HU) is a potent radiation sensitizer, but in vitro studies have suggested that prolonged exposure to HU by way of continuous parenteral infusion would enhance clinical efficacy. The objective of this study was to determine the maximal tolerated dose and identify the toxicities of continuous infusion HU in combination with pelvic and para-aortic external beam radiotherapy (RT) and intrauterine brachytherapy in patients with locally advanced carcinoma of the uterine cervix. Methods: This Phase I study of concomitant RT was designed with an escalating dose schedule of HU administered by continuous infusion. HU was administered parenterally as a continuous infusion, 5 d/wk, during the first 21 days of external radiation, during the final 5 days of external beam RT, followed by another 5-day infusion schedule bracketing the single fraction of brachytherapy. The maximal tolerated dose was defined as the highest dose level at which 3 of 3 or 5 of 6 patients could be treated without dose-limiting toxicity. Results: At dose level 1 (0.25 mg/m 2 /min), 0 of 4 patients experienced Grade 4 toxicities and 2 patients experienced Grade 3 hematologic toxicities that were not considered dose-limiting. One of the first 4 patients at level 2 (0.375 mg/m 2 /min) had Grade 3 diarrhea, but the 3 subsequent patients tolerated the dose. At level 3 (0.5 mg/m 2 /min), 4 of 5 patients failed to complete therapy without a >7-day interruption in HU. Conclusions: The maximal tolerated dose of parenteral HU was 0.375 mg/m 2 /min when administered with concomitant RT. The most common toxicities were hematologic. A new trial, incorporating concurrent cisplatin, HU, and RT is planned

  13. Electrostatic accelerators

    OpenAIRE

    Hinterberger, F

    2006-01-01

    The principle of electrostatic accelerators is presented. We consider Cockcroft– Walton, Van de Graaff and Tandem Van de Graaff accelerators. We resume high voltage generators such as cascade generators, Van de Graaff band generators, Pelletron generators, Laddertron generators and Dynamitron generators. The speci c features of accelerating tubes, ion optics and methods of voltage stabilization are described. We discuss the characteristic beam properties and the variety of possible beams. We ...

  14. Electrostatic accelerators

    CERN Document Server

    Hinterberger, F

    2006-01-01

    The principle of electrostatic accelerators is presented. We consider Cockcroft– Walton, Van de Graaff and Tandem Van de Graaff accelerators. We resume high voltage generators such as cascade generators, Van de Graaff band generators, Pelletron generators, Laddertron generators and Dynamitron generators. The speci c features of accelerating tubes, ion optics and methods of voltage stabilization are described. We discuss the characteristic beam properties and the variety of possible beams. We sketch possible applications and the progress in the development of electrostatic accelerators.

  15. Acceleration of plasma into vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, John [Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1958-07-01

    The first part of this paper is a discussion of the magnetic acceleration of plasma. The second part contains a description of some experiments which have been performed. In the work reported the intention is: 1. To produce a burst of gas in vacuo; 2. To ionize the gas and heat it to such an extent that it becomes a good electrical conductor. 3. To accelerate the plasma thus produced into vacuum by the use of external time-varying magnetic fields.

  16. Rectal Bleeding After High-Dose-Rate Brachytherapy Combined With Hypofractionated External-Beam Radiotherapy for Localized Prostate Cancer: The Relationship Between Dose-Volume Histogram Parameters and the Occurrence Rate

    International Nuclear Information System (INIS)

    Okamoto, Masahiko; Ishikawa, Hitoshi; Ebara, Takeshi; Kato, Hiroyuki; Tamaki, Tomoaki; Akimoto, Tetsuo; Ito, Kazuto; Miyakubo, Mai; Yamamoto, Takumi; Suzuki, Kazuhiro; Takahashi, Takeo; Nakano, Takashi

    2012-01-01

    Purpose: To determine the predictive risk factors for Grade 2 or worse rectal bleeding after high-dose-rate brachytherapy (HDR-BT) combined with hypofractionated external-beam radiotherapy (EBRT) for prostate cancer using dose–volume histogram analysis. Methods and Materials: The records of 216 patients treated with HDR-BT combined with EBRT were analyzed. The treatment protocols for HDR-BT were 5 Gy × five times in 3 days or 7 Gy × three, 10.5 Gy × two, or 9 Gy × two in 2 days. The EBRT doses ranged from 45 to 51 Gy with a fractional dose of 3 Gy. Results: In 20 patients Grade 2 or worse rectal bleeding developed, and the cumulative incidence rate was 9% at 5 years. By converting the HDR-BT and EBRT radiation doses into biologic effective doses (BED), the BED 3 at rectal volumes of 5% and 10% in the patients who experienced bleeding were significantly higher than those in the remaining 196 patients. Univariate analysis showed that a higher rectal BED 3–5% and the use of fewer needles in brachytherapy were correlated with the incidence of bleeding, but BED 3–5% was found to be the only significant factor on multivariate analysis. Conclusions: The radiation dose delivered to small rectal lesions as 5% is important for predicting Grade 2 or worse rectal bleeding after HDR-BT combined with EBRT for prostate cancer.

  17. Phase II trial of combined surgical resection, intraoperative high dose rate brachytherapy (IORT), and external beam radiation therapy (EBRT) for malignant pleural mesothelioma (MPM)

    International Nuclear Information System (INIS)

    Raben, A.; Rusch, V.; Mychalczak, B.; Schupak, K.; Ginsburg, R.; Burt, M.; Bains, M.; Harrison, L.B.

    1996-01-01

    The purpose of this study was to determine the feasibility of combining extrapleural pneumonectomy (EPP) or pleurectomy/decortication (PD), IORT and postoperative EBRT to treat MPM. From (3(94)) through (9(94)), 16 patients (pts) were enrolled on this trial; 2 females and 14 males with a median age of 59 (range: 45 - 75). Eligibility criteria included biopsy proven MPM, no evidence of T4 or N3 disease by exam/CT scan, no evidence of metastatic disease, no previous treatment, and a Karnofsky performance status of ≥ 80%. Pts with pulmonary function tests permitting EPP, underwent EPP and IORT (15 Gy prescribed to a depth of 5 mm in tissue to the mediastinum, diaphragm and chestwall) with postoperative EBRT (54 Gy to entire hemithorax, surgical scar and surgical drain site). Pts ineligible for EPP due to marginal pulmonary function underwent PD and IORT (15 Gy to mediastinum, diaphragm and chestwall), with EBRT (54 Gy to entire hemithorax with customized lung blocking). The median surgical procedure time, median IORT time and median overall operating time was 554 minutes, 240 minutes and 649 minutes respectively. The median dose of EBRT was 50.4 Gy (range 50-54 Gy). The median follow-up time is 8 months (range: 3 - 17 months). Four of 16 pts had unresectable disease at the time of surgery and were taken off study. Eight pts underwent EPP/IORT and 4 patients underwent PD/IORT. A complete resection of all gross disease was obtained in 11pts. One pt had a single focus of gross residual disease (less than 5 mm in size) left behind. The overall actuarial local control at 1 year for resected patients is 66%. The crude local control rate and distant control rate for pts undergoing EPP was 75% and 50% respectively. The crude local control rate and distant control rate for PD pts was 50% and 75%. The overall distant metastasis rate at 1 year was 42%. The overall complication rate was 58% ((7(12))). Of the 8 pts undergoing EPP and IORT, 1 patient developed postoperative acute

  18. Vehicle accelerated corrosion test procedures for automotive in Malaysia

    Directory of Open Access Journals (Sweden)

    Anuar Liza

    2017-01-01

    Full Text Available An accelerated corrosion test, known as proving ground accelerated test, is commonly performed by automotive manufacturers to evaluate the corrosion performance of a vehicle. The test combines corrosion and durability inputs to detect potential failures that may occur during in-service conditions. Currently, the test is conducted at an external test center overseas. Such test is aimed to simulate the effects of one year accelerated corrosion in severe corrosive environment of the north-east and south east of America. However, the test results obtained do not correlate with the actual corrosion conditions observed in the Malaysian market, which is likely attributed to the different test environment of the tropical climate of vehicles in service. Therefore, a vehicle accelerated corrosion test procedure that suits the Malaysian market is proposed and benchmarked with other global car manufacturers that have their own dedicated corrosion test procedure. In the present work, a test track is used as the corrosion test ground and consists of various types of roads for structural durability exposures. Corrosion related facilities like salt trough, mud trough and gravel road are constructed as addition to the existing facilities. The establishment of accelerated corrosion test facilities has contributed to the development of initial accelerated corrosion test procedure for the national car manufacturer. The corrosion exposure is monitored by fitting test coupons at the underbody of test vehicle using mass loss technique so that the desired corrosion rate capable of simulating the real time corrosion effects for its target market.

  19. RECIRCULATING ACCELERATION

    International Nuclear Information System (INIS)

    BERG, J.S.; GARREN, A.A.; JOHNSTONE, C.

    2000-01-01

    This paper compares various types of recirculating accelerators, outlining the advantages and disadvantages of various approaches. The accelerators are characterized according to the types of arcs they use: whether there is a single arc for the entire recirculator or there are multiple arcs, and whether the arc(s) are isochronous or non-isochronous

  20. LIBO accelerates

    CERN Multimedia

    2002-01-01

    The prototype module of LIBO, a linear accelerator project designed for cancer therapy, has passed its first proton-beam acceleration test. In parallel a new version - LIBO-30 - is being developed, which promises to open up even more interesting avenues.

  1. Accelerating Inspire

    CERN Document Server

    AUTHOR|(CDS)2266999

    2017-01-01

    CERN has been involved in the dissemination of scientific results since its early days and has continuously updated the distribution channels. Currently, Inspire hosts catalogues of articles, authors, institutions, conferences, jobs, experiments, journals and more. Successful orientation among this amount of data requires comprehensive linking between the content. Inspire has lacked a system for linking experiments and articles together based on which accelerator they were conducted at. The purpose of this project has been to create such a system. Records for 156 accelerators were created and all 2913 experiments on Inspire were given corresponding MARC tags. Records of 18404 accelerator physics related bibliographic entries were also tagged with corresponding accelerator tags. Finally, as a part of the endeavour to broaden CERN's presence on Wikipedia, existing Wikipedia articles of accelerators were updated with short descriptions and links to Inspire. In total, 86 Wikipedia articles were updated. This repo...

  2. Technology and applications of advanced accelerator concepts

    CERN Document Server

    Chou, Weiren

    2016-01-01

    Since its invention in the 1920s, particle accelerators have made tremendous progress in accelerator science, technology and applications. However, the fundamental acceleration principle, namely, to apply an external radiofrequency (RF) electric field to accelerate charged particles, remains unchanged. As this method (either room temperature RF or superconducting RF) is approaching its intrinsic limitation in acceleration gradient (measured in MeV/m), it becomes apparent that new methods with much higher acceleration gradient (measured in GeV/m) must be found for future very high energy accelerators as well as future compact (table-top or room-size) accelerators. This volume introduces a number of advanced accelerator concepts (AAC) — their principles, technologies and potential applications. For the time being, none of them stands out as a definitive direction in which to go. But these novel ideas are in hot pursuit and look promising. Furthermore, some AAC requires a high power laser system. This has the ...

  3. Ashra Neutrino Telescope Array (NTA): Combined Imaging Observation of Astroparticles — For Clear Identification of Cosmic Accelerators and Fundamental Physics Using Cosmic Beams —

    Science.gov (United States)

    Sasaki, Makoto; Kifune, Tadashi

    In VHEPA (very high energy particle astronomy) 2014 workshop, focused on the next generation explorers for the origin of cosmic rays, held in Kashiwa, Japan, reviewing and discussions were presented on the status of the observation of GeV-TeV photons, TeV-PeV neutrinos, EeV-ZeV hadrons, test of interaction models with Large Hadron Collider (LHC), and theoretical aspects of astrophysics. The acceleration sites of hadrons, i.e., sources of PeV-EeV cosmic rays, should exist in the universe within the GZK-horizon even in the remotest case. We also affirmed that the hadron acceleration mechanism correlates with cosmic ray composition so that it is important to investigate the acceleration mechanism in relevance to the composition survey at PeV-EeV energy. We regard that LHC and astrophysics theories are ready to be used to probe into hadron acceleration mechanism in the universe. Recently, IceCube has reported detection of three events of neutrinos with energies around 1 PeV and additional events at lower energies, which significantly deviate from the expected level of background events. It is necessary to observe GeV-TeV photon, EeV-ZeV hadron and TeV-PeV neutrino all together, in order to understand hadronic interactions of cosmic rays in the PeV-EeV energy region. It is required to make a step further toward exploring the PeV-EeV universe with high accuracy and high statistics observations for both neutrinos and gamma rays simultaneously, by using the instrument such as Ashra Neutrino Telescope Array (NTA). Wide and fine survey of gamma-rays and neutrinos with simultaneously detecting Cherenkov and fluorescence light with NTA will guide us to a new intriguing stage of recognizing astronomical objects and non-thermal phenomena in ultra-high energy region, in addition, new aspect about the fundamental concepts of physics beyond our presently limited understanding; the longstanding problem of cosmic ray origin, the radiation mechanism of gamma-rays, neutrino and

  4. FMIT accelerator

    International Nuclear Information System (INIS)

    Armstrong, D.D.

    1983-01-01

    A 35-MeV 100-mA cw linear accelerator is being designed by Los Alamos for use in the Fusion Materials Irradiation Test (FMIT) Facility. Essential to this program is the design, construction, and evaluation of performance of the accelerator's injector, low-energy beam transport, and radio-frequency quadrupole sections before they are shipped to the facility site. The installation and testing of some of these sections have begun as well as the testing of the rf, noninterceptive beam diagnostics, computer control, dc power, and vacuum systems. An overview of the accelerator systems and the performance to date is given

  5. Electron accelerator

    International Nuclear Information System (INIS)

    Abramyan.

    1981-01-01

    The USSR produces an electron accelerator family of a simple design powered straight from the mains. The specifications are given of accelerators ELITA-400, ELITA-3, ELT-2, TEUS-3 and RIUS-5 with maximum electron energies of 0.3 to 5 MeV, a mean power of 10 to 70 kW operating in both the pulsed and the continuous (TEUS-3) modes. Pulsed accelerators ELITA-400 and ELITA-3 and RIUS-5 in which TESLA resonance transformers are used are characterized by their compact size. (Ha)

  6. Power Transfer to plasma Coxial accelerator

    International Nuclear Information System (INIS)

    El-Aragi, G.M.; Soliman, H.M.; Masoud, M.M.

    2000-01-01

    The total power transfer from the condenser bank, to plasma coaxial accelerator device is theoretically studied by using the voltage equation of the entire circuit and applying impulse - linear momentum theorem. This total power represents a combination of (a) the power flowing to the external inductance, (b) the power flowing to the inductance of that part of electrode system between the breech and the momentary position of the plasma current sheath, (c) the power flowing in the annular space between the two coaxial electrodes, to form the magnetic field induction, (d) the power flowing to accelerate the initial mass, (e) the power flowing to accelerate the mass, which has been swept up into the plasma current sheath, (f) the power, which produces directed kinetic energy for the plasma current sheath, (g) the power, which produces internal energy in the plasma sheath, (h) the joule heating. The peak value of the total power = 6x10 8 watt at t=4 MUs, for maximum calculated discharge current = 110KA with a with a period of 34 us. Experimentally its equal to 3.5x10 8 watt at 7MUs and I 0 = 85KA. The energy flow to the coaxial discharge system has been evaluated theoretically and experimentally, E-MAX (CALCULATED)=5.92X10 2 J AT T = 5.5 MUs and E m ax (measured) = 3.54x10 2 joule at 7.5 MUs

  7. Horizontal Accelerator

    Data.gov (United States)

    Federal Laboratory Consortium — The Horizontal Accelerator (HA) Facility is a versatile research tool available for use on projects requiring simulation of the crash environment. The HA Facility is...

  8. Acceleration theorems

    International Nuclear Information System (INIS)

    Palmer, R.

    1994-06-01

    Electromagnetic fields can be separated into near and far components. Near fields are extensions of static fields. They do not radiate, and they fall off more rapidly from a source than far fields. Near fields can accelerate particles, but the ratio of acceleration to source fields at a distance R, is always less than R/λ or 1, whichever is smaller. Far fields can be represented as sums of plane parallel, transversely polarized waves that travel at the velocity of light. A single such wave in a vacuum cannot give continuous acceleration, and it is shown that no sums of such waves can give net first order acceleration. This theorem is proven in three different ways; each method showing a different aspect of the situation

  9. Genitourinary Toxicity After High-Dose-Rate (HDR) Brachytherapy Combined With Hypofractionated External Beam Radiotherapy for Localized Prostate Cancer: An Analysis to Determine the Correlation Between Dose-Volume Histogram Parameters in HDR Brachytherapy and Severity of Toxicity

    International Nuclear Information System (INIS)

    Ishiyama, Hiromichi; Kitano, Masashi; Satoh, Takefumi; Kotani, Shouko; Uemae, Mineko; Matsumoto, Kazumasa; Okusa, Hiroshi; Tabata, Ken-ichi; Baba, Shiro; Hayakawa, Kazushige

    2009-01-01

    Purpose: To evaluate the severity of genitourinary (GU) toxicity in high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiotherapy (EBRT) for prostate cancer and to explore factors that might affect the severity of GU toxicity. Methods and Materials: A total of 100 Japanese men with prostate cancer underwent 192 Ir HDR brachytherapy combined with hypofractionated EBRT. Mean (SD) dose to 90% of the planning target volume was 6.3 (0.7) Gy per fraction of HDR. After 5 fractions of HDR treatment, EBRT with 10 fractions of 3 Gy was administrated. The urethral volume receiving 1-15 Gy per fraction in HDR brachytherapy (V1-V15) and the dose to at least 5-100% of urethral volume in HDR brachytherapy (D5-D100) were compared between patients with Grade 3 toxicity and those with Grade 0-2 toxicity. Prostate volume, patient age, and International Prostate Symptom Score were also compared between the two groups. Results: Of the 100 patients, 6 displayed Grade 3 acute GU toxicity, and 12 displayed Grade 3 late GU toxicity. Regarding acute GU toxicity, values of V1, V2, V3, and V4 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Regarding late GU toxicity, values of D70, D80, V12, and V13 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Conclusions: The severity of GU toxicity in HDR brachytherapy combined with hypofractionated EBRT for prostate cancer was relatively high. The volume of prostatic urethra was associated with grade of acute GU toxicity, and urethral dose was associated with grade of late GU toxicity.

  10. Ion accelerators for space

    International Nuclear Information System (INIS)

    Slobodrian, R.J.; Potvin, L.

    1991-01-01

    The main purpose of the accelerators is to allow ion implantation in space stations and their neighborhoods. There are several applications of interest immediately useful in such environment: as ion engines and thrusters, as implanters for material science and for hardening of surfaces (relevant to improve resistance to micrometeorite bombardment of exposed external components), production of man made alloys, etc. The microgravity environment of space stations allows the production of substances (crystalline and amorphous) under conditions unknown on earth, leading to special materials. Ion implantation in situ of those materials would thus lead uninterruptedly to new substances. Accelerators for space require special design. On the one hand it is possible to forego vacuum systems simplifying the design and operation but, on the other hand, it is necessary to pay special attention to heat dissipation. Hence it is necessary to construct a simulator in vacuum to properly test prototypes under conditions prevailing in space

  11. Rapidly alternating combination of cisplatin-based chemotherapy and hyperfractionated accelerated radiotherapy in split course for Stage IIIA and Stage IIIB non-small cell lung cancer: results of a Phase I-II study by the GOTHA group

    Energy Technology Data Exchange (ETDEWEB)

    Alberto, P.; Mermillod, B. [Hopital Cantonal Geneve, Geneva (Switzerland); Mirimanoff, R.O.; Leyvraz, S.; Nagy-Mignotte, H.; Bolla, M.; Wellmann, D.; Moro, D.; Brambilla, E. [Hopital Cantonal Universitaire, Lausanne (Switzerland)

    1995-08-01

    The prognosis of stage III non-small cell lung cancer (NSCLC) can be improved by a combination of radiotherapy (RT) and chemotherapy (CT). In this study, the GOTHA group evaluated the feasibility, tolerance, tumour response, pattern of failure and effect on survival of a combination alternating accelerated hyperfractionated (AH) RT and CT in patients with tumour stage III NSCLC. Toxic effects were leucopenia, nausea and vomiting, mucositis, diarrhoea, alopecia and peripheral neuropathy. Alternating CT and AHRT, as used in this study, were well tolerated and allowed full dose delivery within less than 12 weeks. Initial response was not predictive of survival. The survival curve is encouraging and the 5 year survival is superior to the 5% generally observed with conventionally fractionated radiotherapy. (author).

  12. Prospects for Accelerator Technology

    Science.gov (United States)

    Todd, Alan

    2011-02-01

    Accelerator technology today is a greater than US$5 billion per annum business. Development of higher-performance technology with improved reliability that delivers reduced system size and life cycle cost is expected to significantly increase the total accelerator technology market and open up new application sales. Potential future directions are identified and pitfalls in new market penetration are considered. Both of the present big market segments, medical radiation therapy units and semiconductor ion implanters, are approaching the "maturity" phase of their product cycles, where incremental development rather than paradigm shifts is the norm, but they should continue to dominate commercial sales for some time. It is anticipated that large discovery-science accelerators will continue to provide a specialty market beset by the unpredictable cycles resulting from the scale of the projects themselves, coupled with external political and economic drivers. Although fraught with differing market entry difficulties, the security and environmental markets, together with new, as yet unrealized, industrial material processing applications, are expected to provide the bulk of future commercial accelerator technology growth.

  13. Beam front accelerators

    International Nuclear Information System (INIS)

    Reiser, M.

    1982-01-01

    An intense relativistic electron beam cannot propagate in a metal drift tube when the current exceeds the space charge limit. Very high charge density and electric field gradients (10 2 to 10 3 MV/m) develop at the beam front and the electrons are reflected. When a neutral gas or a plasma is present, collective acceleration of positive ions occur, and the resulting charge neutralization enables the beam to propagate. Experimental results, theoretical understanding, and schemes to achieve high ion energies by external control of the beam front velocity will be reviewed

  14. Combination of cathodic reduction with adsorption for accelerated removal of Cr(VI) through reticulated vitreous carbon electrodes modified with sulfuric acid–glycine co-doped polyaniline

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Xi [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China); Yang, Zhao-hui, E-mail: yzh@hnu.edu.cn [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China); Xu, Hai-yin; Zeng, Guang-ming; Huang, Jing; Yang, Xia; Song, Pei-pei; Wang, Li-ke [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China)

    2015-04-09

    Highlights: • RVC/PANI-SA-GLY electrode was applied as a novel electrode material for accelerated removal of Cr(VI). • Faster reduction kinetics of Cr(VI) was observed by RVC/PANI-SA-GLY electrode when compared with RVC/PANI-SA and RVC electrode. • Cr(VI) removal experienced an adsorption-reduction system built by RVC/PANI-SA-GLY electrode. • The stability of RVC/PANI-SA-GLY electrode was relatively satisfactory. - Abstract: Improving the reduction kinetics is crucial in the electroreduction process of Cr(VI). In this study, we developed a novel adsorption–electroreduction system for accelerated removal of Cr(VI) by employing reticulated vitreous carbon electrode modified with sulfuric acid–glycine co-doped polyaniline (RVC/PANI-SA-GLY). Firstly, response surface methodology confirmed the optimum polymerization condition of co-doped polyaniline for modifying electrodes (Aniline, sulfuric acid and glycine, respectively, of 0.2 mol/L, 0.85 mol/L, 0.93 mol/L) when untraditional dopant glycine was added. Subsequently, RVC/PANI-SA-GLY showed higher Cr(VI) removal percentages in electroreduction experiments over RVC electrode modified with sulfuric acid doped polyaniline (RVC/PANI-SA) and bare RVC electrode. In contrast to RVC/PANI-SA, the improvement by RVC/PANI-SA-GLY was more significant and especially obvious at more negative potential, lower initial Cr(VI) concentration, relatively less acidic solution and higher current densities, best achieving 7.84% higher removal efficiency with entire Cr(VI) eliminated after 900 s. Current efficiencies were likewise enhanced by RVC/PANI-SA-GLY under quite negative potentials. Fourier transform infrared (FTIR) and energy dispersive spectrometer (EDS) analysis revealed a possible adsorption–reduction mechanism of RVC/PANI-SA-GLY, which greatly contributed to the faster reduction kinetics and was probably relative to the absorption between protonated amine groups of glycine and HCrO{sub 4}{sup −}. Eventually, the

  15. Acceleration of liquid by boiling of other volatile liquid, (4)

    International Nuclear Information System (INIS)

    Hijikata, Kunio; Mori, Yasuo

    1978-01-01

    In the development of liquid metal MHD power generation using liquid metal as a working fluid, it is one of the important problems to accelerate liquid metal efficiently by means of thermal energy. Though various accelerating methods have been proposed so far, those do not provide high cycle thermal efficiency because of either small electric conductivity, low accelerating efficiency or low gas-liquid separating efficiency. The authors proposed the method to accelerate through volume expansion by boiling a volatile liquid being blown into liquid metal at high temperature, and have investigated it experimentally and theoretically. In the study, efficiency has been discussed in case of the acceleration of fluid subjected to magneto-hydrodynamical force by boiling of droplets of other liquid. Theoretically, the field of flow and two-phase cycle and gas phase cycle were analyzed. The report describes on these results and discussions. It is concluded that efficiency is independent of the injected amount and position of droplets, final efficiency is little affected by external load and thermal conductivity of volatile liquid droplets, the efficiency for the combination of cesium and lead is about 50%, and the method proposed by authors seems to be better than the conventional methods with gas phase cycle proposed so far using inert gas bubbles in lieu of volatile liquid. (Wakatsuki, Y.)

  16. Two-stage open reduction and internal fixation versus limited internal fixation combined with external fixation: a meta-analysis of postoperative complications in patients with severe Pilon fractures.

    Science.gov (United States)

    Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He

    2018-01-01

    Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.

  17. Anatomy-based inverse optimization in high-dose-rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer: Comparison of incidence of acute genitourinary toxicity between anatomy-based inverse optimization and geometric optimization

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Katoh, Hiroyuki; Kitamoto, Yoshizumi; Shirai, Katsuyuki; Shioya, Mariko; Nakano, Takashi

    2006-01-01

    Purpose: To evaluate the advantages of anatomy-based inverse optimization (IO) in planning high-dose-rate (HDR) brachytherapy. Methods and Materials: A total of 114 patients who received HDR brachytherapy (9 Gy in two fractions) combined with hypofractionated external beam radiotherapy (EBRT) were analyzed. The dose distributions of HDR brachytherapy were optimized using geometric optimization (GO) in 70 patients and by anatomy-based IO in the remaining 44 patients. The correlation between the dose-volume histogram parameters, including the urethral dose and the incidence of acute genitourinary (GU) toxicity, was evaluated. Results: The averaged values of the percentage of volume receiving 80-150% of the prescribed minimal peripheral dose (V 8 -V 15 ) of the urethra generated by anatomy-based IO were significantly lower than the corresponding values generated by GO. Similarly, the averaged values of the minimal dose received by 5-50% of the target volume (D 5 -D 5 ) obtained using anatomy-based IO were significantly lower than those obtained using GO. Regarding acute toxicity, Grade 2 or worse acute GU toxicity developed in 23% of all patients, but was significantly lower in patients for whom anatomy-based IO (16%) was used than in those for whom GO was used (37%), consistent with the reduced urethral dose (p <0.01). Conclusion: The results of this study suggest that anatomy-based IO is superior to GO for dose optimization in HDR brachytherapy for prostate cancer

  18. Accelerator microanalysis

    International Nuclear Information System (INIS)

    Tuniz, C.

    1997-01-01

    Particle accelerators have been developed more than sixty years ago to investigate nuclear and atomic phenomena. A major shift toward applications of accelerators in the study of materials structure and composition in inter-disciplinary projects has been witnessed in the last two decades. The Australian Nuclear Science and Technology Organisation (ANSTO) has developed advanced research programs based on the use of particle and photon beams. Atmospheric pollution problems are investigated at the 3 MV Van de Graff accelerator using ion beam analysis techniques to detect toxic elements in aerosol particles. High temperature superconductor and semiconductor materials are characterised using the recoil of iodine and other heavy ions produced at ANTARES, the 10-MV Tandem accelerator. A heavy-ion microprobe is presently being developed at ANTARES to map elemental concentrations of specific elements with micro-size resolution. An Accelerator mass Spectrometry (AMS) system has been developed at ANSTO for the ultra-sensitive detection of Carbon-14, Iodine-129 and other long-lived radioisotopes. This AMS spectrometer is a key instrument for climate change studies and international safeguards. ANSTO is also managing the Australian Synchrotron Research program based on facilities developed at the Photon Factory (Japan) and at the Advanced Photon Source (USA). Advanced projects in biology, materials chemistry, structural condensed matter and other disciplines are being promoted by a consortium involving Australian universities and research institutions. This paper will review recent advances in the use of particle accelerators, with a particular emphasis on applications developed at ANSTO and related to problems of international concern, such as global environmental change, public health and nuclear proliferation

  19. Winning Combinations

    DEFF Research Database (Denmark)

    Criscuolo, Paola; Laursen, Keld; Reichstein, Toke

    2018-01-01

    examine the effectiveness of different combinations of knowledge sources for achieving innovative performance. We suggest that combinations involving integrative search strategies – combining internal and external knowledge – are the most likely to generate product and process innovation. In this context......, we present the idea that cognitively distant knowledge sources are helpful for innovation only when used in conjunction with knowledge sources that are closer to the focal firm. We also find important differences between product and process innovation, with the former associated with broader searches......Searching for the most rewarding sources of innovative ideas remains a key challenge in management of technological innovation. Yet, little is known about which combinations of internal and external knowledge sources are triggers for innovation. Extending theories about searching for innovation, we...

  20. An Accelerated Multi-Modality Rehabilitation Protocol Combined with Botulinum Toxin-A Injection in Adult Idiopathic Toe Walking: Case Report

    Science.gov (United States)

    Yavuz, Ferdi; Balaban, Birol

    2016-01-01

    Diagnosis of Adult Idiopathic Toe Walking (AITW) is very rare in clinical practice. High quality studies regarding AITW and its treatment options have not been conducted previously. A 28-year-old male patient complaining of lower leg pain was referred to outpatient rehabilitation clinic. Physical examination revealed a gait abnormality of insufficient heel strike at initial contact. The aetiology was investigated and the patient’s walking parameters were assessed using a computerized gait analysis system. The AITW was diagnosed. Botulinum toxin-A (Dysport®) was injected to the bilateral gastrocnemius muscles. A combined 10-days rehabilitation program was designed, including a daily one-hour physiotherapist supervised exercise program, ankle dorsiflexion exercises using an EMG-biofeedback unit assisted virtual rehabilitation system (Biometrics) and virtual gait training (Rehawalk) every other day. After treatment, the patient was able to heel strike at the initiation of the stance phase of the gait. Ankle dorsiflexion range of motions increased. The most prominent improvement was seen in maximum pressure and heel force. In addition center of pressure evaluations were also improved. To the best of our knowledge this is the first case, of AITW treated with combined botulinum toxin, exercise and virtual rehabilitation systems. This short report demonstrates the rapid effect of this 10-days combined therapy. PMID:27504395

  1. Externalities of energy. Swedish implementation of the ExternE methodology

    International Nuclear Information System (INIS)

    Nilsson, Maans; Gullberg, M.

    1998-01-01

    The growing interest for developing economic instruments for efficient environmental policies has opened up a large area of multi-disciplinary research. ExternE is an example of this research, combining disciplines such as engineering, ecology, immunology and economics expertise to create new knowledge about how environmental pressures from energy production affect our nature and society. The ExternE Project aims to identify and, as far as possible quantify the externalities of energy production in Europe. The Stockholm Environment Institute has carried out a preliminary aggregation: -Coal Fuel Cycle: centred around Vaesteraas Kraftvaermeverk, Vaesteraas. This is the largest co-generation plant in Sweden, with four blocks and a maximum co-generation output of 520 MW electricity and 950 MW heat. The analysis is carried out on boiler B4. -Biomass Fuel Cycle: centred around Haendeloeverket, Norrkoeping. This plant predominately burns forestry residues, but a variety of fuels are combusted. Haendeloeverket has an installed capacity of 100 MW electricity and 375 MW heat, in a total of three boilers and two back-pressure turbines. The analysis is carried out on boiler P13. -Hydro Fuel Cycle: Klippens Kraftstation, Storuman. Built in 1990-1994, it is the youngest hydro power station in Sweden. It has been designed and built with significant efforts to account for and protect environmental values. Installed capacity is 28 MW. The environmental impact assessment from the construction of this plant is carried out, but the evaluation is still not finalized. The preliminary aggregation aimed to test whether ExternE results could be used to make estimates for the entire Swedish electricity production system. Hence, national results as well as results from other partner countries in ExternE has been applied

  2. Liver acquisition with acceleration volume acquisition gadolinium-enhanced magnetic resonance combined with T2 sequences in the diagnosis of local recurrence of rectal cancer.

    Science.gov (United States)

    Cao, Wuteng; Li, Fangqian; Gong, Jiaying; Liu, Dechao; Deng, Yanhong; Kang, Liang; Zhou, Zhiyang

    2016-11-22

    To investigate the efficacy of liver acquisition with acceleration volume acquisition (LAVA) gadolinium-enhanced magnetic resonance (MR) sequences and to assess its added accuracy in diagnosing local recurrence (LR) of rectal cancer with conventional T2-weighted fast spin echo (FSE) sequences. Pelvic MRI, including T2-weighted FSE sequences, gadolinium-enhanced sequences of LAVA and T1-weighted FSE with fat suppression, was performed on 225 patients with postoperative rectal cancer. Two readers evaluated the presence of LR according to "T2" (T2 sequences only), "T2 + LAVA-Gad" (LAVA and T2 imaging), and "T2 + T1-fs-Gad" (T1 fat suppression-enhanced sequence with T2 images). To evaluate diagnostic efficiency, imaging quality with LAVA and T1-fs-Gad by subjective scores and the signal intensity (SI) ratio. In the result, the SI ratio of LAVA was significantly higher than that of T1-fs-Gad (p = 0.0001). The diagnostic efficiency of "T2 + LAVA-Gad" was better than that of "T2 + T1-fs-Gad" (p = 0.0016 for Reader 1, p = 0.0001 for Reader 2) and T2 imaging only (p = 0.0001 for Reader 1; p = 0.0001 for Reader 2). Therefore, LAVA gadolinium-enhanced MR increases the accuracy of diagnosis of LR from rectal cancer and could replace conventional T1 gadolinium-enhanced sequences in the postoperative pelvic follow-up of rectal cancer.

  3. Universality of accelerating change

    Science.gov (United States)

    Eliazar, Iddo; Shlesinger, Michael F.

    2018-03-01

    On large time scales the progress of human technology follows an exponential growth trend that is termed accelerating change. The exponential growth trend is commonly considered to be the amalgamated effect of consecutive technology revolutions - where the progress carried in by each technology revolution follows an S-curve, and where the aging of each technology revolution drives humanity to push for the next technology revolution. Thus, as a collective, mankind is the 'intelligent designer' of accelerating change. In this paper we establish that the exponential growth trend - and only this trend - emerges universally, on large time scales, from systems that combine together two elements: randomness and amalgamation. Hence, the universal generation of accelerating change can be attained by systems with no 'intelligent designer'.

  4. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This section is concerned with the operation of both the tandem-linac system and the Dynamitron, two accelerators that are used for entirely different research. Developmental activities associated with the tandem and the Dynamitron are also treated here, but developmental activities associated with the superconducting linac are covered separately because this work is a program of technology development in its own right

  5. CNSTN Accelerator

    International Nuclear Information System (INIS)

    Habbassi, Afifa; Trabelsi, Adel

    2010-01-01

    This project give a big idea about the measurement of the linear accelerator in the CNSTN. During this work we control dose distribution for different product. For this characterisation we have to make an installation qualification ,operational qualification,performance qualification and of course for every step we have to control temperature and the dose ,even the distribution of the last one.

  6. Accelerators course

    CERN Multimedia

    CERN. Geneva HR-RFA; Métral, E

    2006-01-01

    1a) Introduction and motivation 1b) History and accelerator types 2) Transverse beam dynamics 3a) Longitudinal beam dynamics 3b) Figure of merit of a synchrotron/collider 3c) Beam control 4) Main limiting factors 5) Technical challenges

  7. Accelerator operations

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Operations of the SuperHILAC, the Bevatron/Bevalac, and the 184-inch Synchrocyclotron during the period from October 1977 to September 1978 are discussed. These include ion source development, accelerator facilities, the Heavy Ion Spectrometer System, and Bevelac biomedical operations

  8. Externality-correcting taxes and regulation

    OpenAIRE

    Christiansen, V.; Smith, S.

    2009-01-01

    Much of the literature on externalities has considered taxes and direct regulation as alternative policy instruments. Both instruments may in practice be imperfect, reflecting informational deficiencies and other limitations. We analyse the use of taxes and regulation in combination, to control externalities arising from individual consumption behaviour. We consider cases where taxes are either imperfectly differentiated to reflect individual differences in externalities, or where some consum...

  9. Acceleration of polarized electrons in the Bonn electron-accelerator facility ELSA

    International Nuclear Information System (INIS)

    Hoffmann, M.

    2001-12-01

    The future medium energy physics program at the electron stretcher accelerator ELSA of Bonn University mainly relies on experiments using polarized electrons in the energy range from 1 to 3.2 GeV. To prevent depolarization during acceleration in the circular accelerators several depolarizing resonances have to be corrected for. Intrinsic resonances are compensated using two pulsed betatron tune jump quadrupoles. The influence of imperfection resonances is successfully reduced applying a dynamic closed orbit correction in combination with an empirical harmonic correction on the energy ramp. Both types of resonances and the correction techniques have been studied in detail. The imperfection resonances were used to calibrate the energy of the stretcher ring with high accuracy. A new technique to extract the beam with horizontal oriented polarization was successfully installed. For all energies a polarized electron beam with more than 50% polarization can now be supplied to the experiments at ELSA, which is demonstrated by measurements using a Moeller polarimeter installed in the external beamline. (orig.)

  10. Tip Deflection Determination of a Barrel for the Effect of an Accelerating Projectile Before Firing Using Finite Element and Artificial Neural Network Combined Algorithm

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Koç

    Full Text Available Abstract For realistic applications, design and control engineers have limited modelling options in dealing with some vibration problems that hold many nonlinearity such as non-uniform geometry, variable velocity loadings, indefinite damping cases, etc. For these reasons numerous time consuming experimental studies at high costs must be done for determining the actual behaviour such nonlinear systems. However, using advantages of multiple computational methods like Finite Element Method (FEM together with an Artificial Intelligence (ANN, many complicated engineering problems can be handled and solved to some extent. This study, proposes a new collective method to deal with the nonlinear vibrations of the barrels in order to fulfil accurate shooting expectancy. Using known analytical methods, in practical, to determine dynamic behaviour of the barrel beam is not possible for all conditions of firing that include numerous varieties of ammunition for different purposes, and each projectile of different ammunition has different mass and exit velocity. In order to cover all cases this study proposes a new method that combines a precise FEM with ANN, and can be used for determining the exact dynamic behaviour of a barrel for some cases and then for precisely predicting the behaviour for all other possible cases of firing. In this study, the whole nonlinear behaviour of an antiaircraft barrel were obtained with 3.5% accuracy errors by ANN trained by FEM using calculated analysis results of ammunitions for a particular range. The proposed FEM-ANN combined method can be very useful for design and control engineers in design and control of barrels in order to compensate the effect of nonlinear vibrations of a barrel for achieving a higher shooting accuracy; and can reduce high-cost experimental works.

  11. Collective focusing ion accelerator

    International Nuclear Information System (INIS)

    Goldin, F.J.

    1986-01-01

    The principal subject of this dissertation is the trapping confinement of pure electron plasmas in bumpy toroidal magnetic fields, with particular attention given to the trapping procedure and the behavior of the plasma during the final equilibrium. The most important aspects of the equilibrium studied were the qualitative nature of the plasma configuration and motion and its density, distribution and stability. The motivation for this study was that an unneutralized cloud of electrons contained in a toroidal system, sufficiently dense and stable, may serve to electrostatically focus ions (against centrifugal and self space charge forces) in a cyclic ion accelerator. Such an accelerator, known as a Collective Focusing Ion Accelerator (CFIA) could be far smaller than conventional designs (which use external magnetic fields directly to focus the ions) due to the smaller gyro-radium of an electron in a magnetic field of given strength. The electron cloud generally drifted poloidally at a finite radius from the toroidal minor axis. As this would preclude focusing ions with such clouds, damping this motion was investigated. Finite resistance in the normally perfectly conductive vessel wall did this. In further preparation for a working CFIA, additional experiments studied the effect of ions on the stability of the electron cloud

  12. Regulating multiple externalities

    DEFF Research Database (Denmark)

    Waldo, Staffan; Jensen, Frank; Nielsen, Max

    2016-01-01

    Open access is a well-known externality problem in fisheries causing excess capacity and overfishing. Due to global warming, externality problems from CO2 emissions have gained increased interest. With two externality problems, a first-best optimum can be achieved by using two regulatory instrume......Open access is a well-known externality problem in fisheries causing excess capacity and overfishing. Due to global warming, externality problems from CO2 emissions have gained increased interest. With two externality problems, a first-best optimum can be achieved by using two regulatory...

  13. Accelerating Value Creation with Accelerators

    DEFF Research Database (Denmark)

    Jonsson, Eythor Ivar

    2015-01-01

    and developing the best business ideas and support the due diligence process. Even universities are noticing that the learning experience of the action learning approach is an effective way to develop capabilities and change cultures. Accelerators related to what has historically been associated...

  14. Rippled plasma wall accelerating structures

    International Nuclear Information System (INIS)

    Cavenago, M.

    1992-01-01

    A concept to form a hot, pulsed, inhomogeneous plasma and to use it as a linac structure is presented. The plasma spatial distribution is controlled by an external magnetic field and by the location of thermionic emitters; microwave ECR heating at frequency ω 1 favours plasma build up and reduces plasma resistivity. A shorter microwave pulse with frequency ω 2 ≠ ω 1 excites a longitudinal mode. An expression for the maximum attainable accelerating field is found. A linearized theory of accelerating modes is given. (Author) 6 refs., 3 figs

  15. Induction sensor for measuring the accelerating voltage in an iron-free induction accelerator

    International Nuclear Information System (INIS)

    Bol'nykh, N.S.; Il'in, Yu.M.; Kostyushok, A.A.; Suvorov, V.A.

    1987-01-01

    An inductive sensor is described for measuring the amplitude and form of the accelerating-voltage pulse in the storage coils in a radial iron-free linear induction accelerator. The sensor does not respond to interference from external fields and does not require adjustment after calibration

  16. ExternE National Implementation Finland

    Energy Technology Data Exchange (ETDEWEB)

    Pingoud, K; Maelkki, H; Wihersaari, M; Pirilae, P [VTT Energy, Espoo (Finland); Hongisto, M [Imatran Voima Oy, Vantaa (Finland); Siitonen, S [Ekono Energy Ltd, Espoo (Finland); Johansson, M [Finnish Environment Institute, Helsinki (Finland)

    1999-07-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)

  17. ExternE National Implementation Finland

    International Nuclear Information System (INIS)

    Pingoud, K.; Maelkki, H.; Wihersaari, M.; Pirilae, P.; Hongisto, M.; Siitonen, S.; Johansson, M.

    1999-01-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)

  18. ExternE National Implementation Finland

    Energy Technology Data Exchange (ETDEWEB)

    Pingoud, K.; Maelkki, H.; Wihersaari, M.; Pirilae, P. [VTT Energy, Espoo (Finland); Hongisto, M. [Imatran Voima Oy, Vantaa (Finland); Siitonen, S. [Ekono Energy Ltd, Espoo (Finland); Johansson, M. [Finnish Environment Institute, Helsinki (Finland)

    1999-07-01

    ExternE National Implementation is a continuation of the ExternE Project, funded in part by the European Commission's Joule III Programme. This study is the result of the ExternE National Implementation Project for Finland. Three fuel cycles were selected for the Finnish study: coal, peat and wood-derived biomass, which together are responsible for about 40% of total electricity generation in Finland and about 75% of the non-nuclear fuel based generation. The estimated external costs or damages were dominated by the global warming (GW) impacts in the coal and peat fuel cycles, but knowledge of the true GW impacts is still uncertain. From among other impacts that were valued in monetary terms the human health damages due to airborne emissions dominated in all the three fuel cycles. Monetary valuation for ecosystem impacts is not possible using the ExternE methodology at present. The Meri-Pori power station representing the coal fuel cycle is one of the world's cleanest and most efficient coal-fired power plants with a condensing turbine. The coal is imported mainly from Poland. The estimated health damages were about 4 mECU/kWh, crop damages an order of magnitude lower and damages caused to building materials two orders of magnitude lower. The power stations of the peat and biomass fuel cycles are of CHP type, generating electricity and heat for the district heating systems of two cities. Their fuels are of domestic origin. The estimated health damages allocated to electricity generation were about 5 and 6 mECU/kWh, respectively. The estimates were case-specific and thus an generalisation of the results to the whole electricity generation in Finland is unrealistic. Despite the uncertainties and limitations of the methodology, it is a promising tool in the comparison of similar kinds of fuel cycles, new power plants and pollution abatement technologies and different plant locations with each other. (orig.)

  19. 伏九贴联合捏脊疗法防治小儿哮喘临床研究%Clinical observation of external application therapy combined with chiropractic therapy on the pediatric asthma

    Institute of Scientific and Technical Information of China (English)

    唐敏; 杨红新; 杨建玲; 张岚

    2016-01-01

    Objective To evaluate the effect of external application therapy combined with chiropractic therapy on the pediatric asthma.Methods A total of 55 patients were randomly assigned into the treatment group (28 patients) and the control group (27 patients), The treatment group was treated with external application therapy combined with chiropractic therapyin the the hottest and coldest weather of each year; while the control group was only treated with chiropractic therapy. Both groups were treated for 3 years. After the treatment, the total effective rate, the clinical control rate, and the frequency of asthma attacks were detected.Results The total effective rate was 92.9% (26/28) and the clinical control rate was 64.3% (18/28) in observation group, which were better than those of 70.4% (19/27) and 22.2% (6/27) in the control group (χ2=4.073,P=0.044, andχ2=8.823,P=0.003). After 3 years’ treatment, the asthma grading distributionin the treatment group was significantly different from the control group (χ2=10.776,P=0.005). The frequency of asthma attacks in the treatment group after the first year treatment (4.5 ± 0.5 timesvs. 5.0 ± 0.5 times,t=3.708,P<0.01) was significantly lower than that in the control group; so did the second years after treatment (3.0 ± 0.5 timesvs.4.3 ± 0.5 times,t=9.728,P<0.01), and the third years (1.5 ± 0.5 times vs. 3.0 ± 0.5 times,t=11.225,P<0.01).ConclusionsThe external application therapy combined with chiropractic therapy could prevent asthma in children patients.%目的:评估中药伏九贴联合捏脊疗法防治小儿哮喘的疗效。方法将符合入选标准的小儿哮喘患者55例采用随机数字表法分为治疗组28例,对照组27例,治疗组于每年三伏与三九期间采用伏九贴联合捏脊疗法治疗,对照组单纯行捏脊疗法。2组均治疗3年。治疗结束后观察患儿总有效率与临床控制率,比较2组患儿哮喘发作次数。结果治疗组总有效率为92.9%(26/28)

  20. Modulational effects in accelerators

    International Nuclear Information System (INIS)

    Satogata, T.

    1997-01-01

    We discuss effects of field modulations in accelerators, specifically those that can be used for operational beam diagnostics and beam halo control. In transverse beam dynamics, combined effects of nonlinear resonances and tune modulations influence diffusion rates with applied tune modulation has been demonstrated. In the longitudinal domain, applied RF phase and voltage modulations provide mechanisms for parasitic halo transport, useful in slow crystal extraction. Experimental experiences with transverse tune and RF modulations are also discussed

  1. Laser acceleration

    Science.gov (United States)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-02-01

    The fundamental idea of Laser Wakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wakefields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ˜ c and ultrafastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nanomaterials is also emerging.

  2. Laser acceleration

    International Nuclear Information System (INIS)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-01-01

    The fundamental idea of LaserWakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wake fields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ∼ c and ultra fastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nano materials is also emerging.

  3. Accelerating networks

    International Nuclear Information System (INIS)

    Smith, David M D; Onnela, Jukka-Pekka; Johnson, Neil F

    2007-01-01

    Evolving out-of-equilibrium networks have been under intense scrutiny recently. In many real-world settings the number of links added per new node is not constant but depends on the time at which the node is introduced in the system. This simple idea gives rise to the concept of accelerating networks, for which we review an existing definition and-after finding it somewhat constrictive-offer a new definition. The new definition provided here views network acceleration as a time dependent property of a given system as opposed to being a property of the specific algorithm applied to grow the network. The definition also covers both unweighted and weighted networks. As time-stamped network data becomes increasingly available, the proposed measures may be easily applied to such empirical datasets. As a simple case study we apply the concepts to study the evolution of three different instances of Wikipedia, namely, those in English, German, and Japanese, and find that the networks undergo different acceleration regimes in their evolution

  4. External Otitis (Swimmer's Ear)

    Science.gov (United States)

    ... otitis. Fungal external otitis (otomycosis), typically caused by Aspergillus niger or Candida albicans, is less common. Boils are ... in the ear. Fungal external otitis caused by Aspergillus niger usually causes grayish black or yellow dots (called ...

  5. ExternE: Externalities of energy Vol. 2. Methodology

    International Nuclear Information System (INIS)

    Berry, J.; Holland, M.; Watkiss, P.

    1995-01-01

    This report describes the methodology used by the ExternE Project of the European Commission (DGXII) JOULE Programme for assessment of the external costs of energy. It is one of a series of reports describing analysis of nuclear, fossil and renewable fuel cycles for assessment of the externalities associated with electricity generation. Part I of the report deals with analysis of impacts, and Part II with the economic valuation of those impacts. Analysis is conducted on a marginal basis, to allow the effect of an incremental investment in a given technology to be quantified. Attention has been paid to the specificity of results with respect to the location of fuel cycle activities, the precise technologies used, and the type and source of fuel. The main advantages of this detailed approach are as follows: It takes full and proper account of the variability of impacts that might result from different power projects; It is more transparent than analysis based on hypothetically 'representative' cases for each of the different fuel cycles; It provides a framework for consistent comparison between fuel cycles. A wide variety of impacts have been considered. These include the effects of air pollution on the natural and human environment, consequences of accidents in the workplace, impacts of noise and visual intrusion on amenity, and the effects of climate change arising from the release of greenhouse gases. Wherever possible we have used the 'impact pathway' or 'damage function' approach to follow the analysis from identification of burdens (e.g. emissions) through to impact assessment and then valuation in monetary terms. This has required a detailed knowledge of the technologies involved, pollutant dispersion, analysis of effects on human and environmental health, and economics. In view of this the project brought together a multi-disciplinary team with experts from many European countries and the USA. The spatial and temporal ranges considered in the analysis are

  6. ASH External Web Portal (External Portal) -

    Data.gov (United States)

    Department of Transportation — The ASH External Web Portal is a web-based portal that provides single sign-on functionality, making the web portal a single location from which to be authenticated...

  7. Secondary emission electron gun using external primaries

    Science.gov (United States)

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY

    2009-10-13

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  8. Accelerators and the Accelerator Community

    Energy Technology Data Exchange (ETDEWEB)

    Malamud, Ernest; Sessler, Andrew

    2008-06-01

    In this paper, standing back--looking from afar--and adopting a historical perspective, the field of accelerator science is examined. How it grew, what are the forces that made it what it is, where it is now, and what it is likely to be in the future are the subjects explored. Clearly, a great deal of personal opinion is invoked in this process.

  9. Accelerators and the Accelerator Community

    International Nuclear Information System (INIS)

    Malamud, Ernest; Sessler, Andrew

    2008-01-01

    In this paper, standing back--looking from afar--and adopting a historical perspective, the field of accelerator science is examined. How it grew, what are the forces that made it what it is, where it is now, and what it is likely to be in the future are the subjects explored. Clearly, a great deal of personal opinion is invoked in this process

  10. Heavy ion accelerators at GSI

    International Nuclear Information System (INIS)

    Angert, N.

    1984-01-01

    The status of the Unilac heavy ion linear accelerator at GSI, Darmstadt is given. A schematic overall plan view of the Unilac is shown and its systems are described. List of isotopes and intensities accelerated at the Unilac is presented. The experimental possibilities at GSI should be considerably extended by a heavy ion synchrotron (SIS 18) in combination with an experimental storage ring (ESR). A prototype of the rf-accelerating system of the synchrotron has been built and tested. Prototypes for the quadrupole and dipole magnets for the ring are being constructed. The SIS 18 is desigmed for a maximum magnetic rigidity of 18Tm so that neon can be accelerated to 2 GeV/W and uranium to 1 GeV/u. The design allows also the acceleration of protons up to 4.5 GeV. The ESR permits to storage fully stripped uranium ions up to an energy of approximately R50 MeV/u

  11. accelerating cavity

    CERN Multimedia

    On the inside of the cavity there is a layer of niobium. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment.

  12. Human Sound Externalization in Reverberant Environments

    DEFF Research Database (Denmark)

    Catic, Jasmina

    In everyday environments, listeners perceive sound sources as externalized. In listening conditions where the spatial cues that are relevant for externalization are not represented correctly, such as when listening through headphones or hearing aids, a degraded perception of externalization may...... occur. In this thesis, the spatial cues that arise from a combined effect of filtering due to the head, torso, and pinna and the acoustic environment were analysed and the impact of such cues for the perception of externalization in different frequency regions was investigated. Distant sound sources...... were simulated via headphones using individualized binaural room impulse responses (BRIRs). An investigation of the influence of spectral content of a sound source on externalization showed that effective externalization cues are present across the entire frequency range. The fluctuation of interaural...

  13. Towards a novel laser-driven method of exotic nuclei extraction−acceleration for fundamental physics and technology

    Energy Technology Data Exchange (ETDEWEB)

    Nishiuchi, M., E-mail: sergei@jaea.go.jp; Sakaki, H.; Esirkepov, T. Zh. [Japan Atomic Energy Agency, Kansai Photon Science Institute (Japan); Nishio, K. [Japan Atomic Energy Agency, Advanced Science Research Center (Japan); Pikuz, T. A.; Faenov, A. Ya. [Japan Atomic Energy Agency, Kansai Photon Science Institute (Japan); Skobelev, I. Yu. [Russian Academy of Sciences, Joint Institute for High Temperature (Russian Federation); Orlandi, R. [Japan Atomic Energy Agency, Advanced Science Research Center (Japan); Pirozhkov, A. S.; Sagisaka, A.; Ogura, K.; Kanasaki, M.; Kiriyama, H.; Fukuda, Y. [Japan Atomic Energy Agency, Kansai Photon Science Institute (Japan); Koura, H. [Japan Atomic Energy Agency, Advanced Science Research Center (Japan); Kando, M. [Japan Atomic Energy Agency, Kansai Photon Science Institute (Japan); Yamauchi, T. [Graduate School of Maritime Sciences (Japan); Watanabe, Y. [Kyushu University, Interdisciplinary Graduate School of Engineering Sciences (Japan); Bulanov, S. V., E-mail: svbulanov@gmail.com; Kondo, K. [Japan Atomic Energy Agency, Kansai Photon Science Institute (Japan); and others

    2016-04-15

    A combination of a petawatt laser and nuclear physics techniques can crucially facilitate the measurement of exotic nuclei properties. With numerical simulations and laser-driven experiments we show prospects for the Laser-driven Exotic Nuclei extraction–acceleration method proposed in [M. Nishiuchi et al., Phys, Plasmas 22, 033107 (2015)]: a femtosecond petawatt laser, irradiating a target bombarded by an external ion beam, extracts from the target and accelerates to few GeV highly charged short-lived heavy exotic nuclei created in the target via nuclear reactions.

  14. Prostate Specific Antigen (PSA) as Predicting Marker for Clinical Outcome and Evaluation of Early Toxicity Rate after High-Dose Rate Brachytherapy (HDR-BT) in Combination with Additional External Beam Radiation Therapy (EBRT) for High Risk Prostate Cancer.

    Science.gov (United States)

    Ecke, Thorsten H; Huang-Tiel, Hui-Juan; Golka, Klaus; Selinski, Silvia; Geis, Berit Christine; Koswig, Stephan; Bathe, Katrin; Hallmann, Steffen; Gerullis, Holger

    2016-11-10

    High-dose-rate brachytherapy (HDR-BT) with external beam radiation therapy (EBRT) is a common treatment option for locally advanced prostate cancer (PCa). Seventy-nine male patients (median age 71 years, range 50 to 79) with high-risk PCa underwent HDR-BT following EBRT between December 2009 and January 2016 with a median follow-up of 21 months. HDR-BT was administered in two treatment sessions (one week interval) with 9 Gy per fraction using a planning system and the Ir192 treatment unit GammaMed Plus iX. EBRT was performed with CT-based 3D-conformal treatment planning with a total dose administration of 50.4 Gy with 1.8 Gy per fraction and five fractions per week. Follow-up for all patients was organized one, three, and five years after radiation therapy to evaluate early and late toxicity side effects, metastases, local recurrence, and prostate-specific antigen (PSA) value measured in ng/mL. The evaluated data included age, PSA at time of diagnosis, PSA density, BMI (body mass index), Gleason score, D'Amico risk classification for PCa, digital rectal examination (DRE), PSA value after one/three/five year(s) follow-up (FU), time of follow-up, TNM classification, prostate volume, and early toxicity rates. Early toxicity rates were 8.86% for gastrointestinal, and 6.33% for genitourinary side effects. Of all treated patients, 84.81% had no side effects. All reported complications in early toxicity were grade 1. PSA density at time of diagnosis ( p = 0.009), PSA on date of first HDR-BT ( p = 0.033), and PSA on date of first follow-up after one year ( p = 0.025) have statistical significance on a higher risk to get a local recurrence during follow-up. HDR-BT in combination with additional EBRT in the presented design for high-risk PCa results in high biochemical control rates with minimal side-effects. PSA is a negative predictive biomarker for local recurrence during follow-up. A longer follow-up is needed to assess long-term outcome and toxicities.

  15. Cosmic ray acceleration mechanisms

    International Nuclear Information System (INIS)

    Cesarsky, C.J.

    1982-09-01

    We present a brief summary of some of the most popular theories of cosmic ray acceleration: Fermi acceleration, its application to acceleration by shocks in a scattering medium, and impulsive acceleration by relativistic shocks

  16. ExternE: Externalities of energy Vol. 1. Summary

    International Nuclear Information System (INIS)

    Holland, M.; Berry, J.

    1995-01-01

    There is a growing requirement for policy analysts to take account of the environment in their decision making and to undertake the specified cost-benefit analysis. Within the European Union this is reflected in the 5th Environmental Action Programme, and the Commission's White Paper entitled 'Growth, competitiveness, employment and the ways forward to the 21st century'. This has led to a need for evaluation of environmental externalities. The ExternE Project commenced in 1991 as the European part of a collaborative study between the European Commission and the US Department of Energy. It aims to be the first systematic approach to the evaluation of external costs of a wide range of different fuel cycles. The project will result in an operational accounting framework for the quantification and monetarisation of priority environmental and other externalities. This framework will allow the calculation of the marginal external costs and benefits for specific power plants, at specific sites using specified technologies. There are three major phases in the project. Phase 1 was undertaken in collaboration with the US Department of Energy. In this phase the teams jointly developed the conceptual approach and methodology and shared scientific information for application to a number of fuel cycles. On the European side work concentrated on the nuclear and coal fuel cycles which together were expected to raise many of the fundamental issues in fuel cycle analysis. The project is currently nearing completion of Phase 2. During this phase the methodology has been applied to a wide range of different fossil, nuclear and renewable fuel cycles for power generation and energy conservation options. Also a series of National Implementation Programmes is underway in which the methodology and accounting framework are being applied to reference sites throughout Europe. In addition the general methodology is being extended to address the evaluation of externalities associated with

  17. Externalities of fuel cycles 'ExternE' project. Summary report

    International Nuclear Information System (INIS)

    Holland, M.; Berry, J.

    1994-01-01

    There is a growing requirement for policy analysts to take account of the environment in their decision making and to undertake the specified cost-benefit analysis. Within the European Union this is reflected in the 5th Environmental Action Programme, and the Commission's White Paper entitled 'Growth, competitiveness, employment and the ways forward to the 21st century'. This has led to a need for evaluation of environmental externalities. The ExternE Project commenced in 1991 as the European part of a collaborative study between the European Commission and the US Department of Energy. It aims to be the first systematic approach to the evaluation of external costs of a wide range of different fuel cycles. The project will result in an operational accounting framework for the quantification and monetarisation of priority environmental and other externalities. This framework will allow the calculation of the marginal external costs and benefits for specific power plants, at specific sites using specified technologies. There are three major phases in the project. Phase I was undertaken in collaboration with the US Department of Energy. In this phase the teams jointly developed the conceptual approach and methodology and shared scientific information for application to a number of fuel cycles. On the European side work concentrated on the nuclear and coal fuel cycles which together were expected to raise many of the fundamental issues in fuel cycle analysis. The project is currently nearing completion of Phase 2. During this phase the methodology has been applied to a wide range of different fossil, nuclear and renewable fuel cycles for power generation and energy conservation options. Also a series of National Implementation Programmes are underway in which the methodology and accounting framework are being applied to reference sites throughout Europe. In addition the general methodology is being extended to address the evaluation of externalities associated with

  18. External radiation surveillance

    International Nuclear Information System (INIS)

    Antonio, E.J.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report describes how external radiation was measured, how surveys were performed, and the results of these measurements and surveys. External radiation exposure rates were measured at locations on and off the Hanford Site using thermoluminescent dosimeters (TLD). External radiation and contamination surveys were also performed with portable radiation survey instruments at locations on and around the Hanford Site

  19. External radiation surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, E.J.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report describes how external radiation was measured, how surveys were performed, and the results of these measurements and surveys. External radiation exposure rates were measured at locations on and off the Hanford Site using thermoluminescent dosimeters (TLD). External radiation and contamination surveys were also performed with portable radiation survey instruments at locations on and around the Hanford Site.

  20. Linear particle accelerator

    International Nuclear Information System (INIS)

    Richards, J.A.

    1977-01-01

    A linear particle accelerator which provides a pulsed beam of charged particles of uniform energy is described. The accelerator is in the form of an evacuated dielectric tube, inside of which a particle source is located at one end of the tube, with a target or window located at the other end of the dielectric tube. Along the length of the tube are externally located pairs of metal plates, each insulated from each other in an insulated housing. Each of the plates of a pair are connected to an electrical source of voltage of opposed polarity, with the polarity of the voltage of the plates oriented so that the plate of a pair, nearer to the particle source, is of the opposed polarity to the charge of the particle emitted by the source. Thus, a first plate about the tube located nearest the particle source, attracts a particle which as it passes through the tube past the first plate is then repelled by the reverse polarity of the second plate of the pair to continue moving towards the target

  1. Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Ito, Kazuto; Saitoh, Jun-ichi; Noda, Shin-ei; Harashima, Koichi; Sakurai, Hideyuki; Nakayama, Yuko; Yamamoto, Takumi; Suzuki, Kazuhiro; Nakano, Takashi; Niibe, Hideo

    2005-01-01

    Purpose: Several investigations have revealed that the α/β ratio for prostate cancer is atypically low, and that hypofractionation or high-dose-rate (HDR) brachytherapy regimens using appropriate radiation doses may be expected to yield tumor control and late sequelae rates that are better or at least as favorable as those achieved with conventional radiation therapy. In this setting, we attempted treating localized prostate cancer patients with HDR brachytherapy combined with hypofractionated external beam radiation therapy (EBRT). The purpose of this study was to evaluate the feasibility of using this approach, with special emphasis on the relationship between the severity of acute genitourinary (GU) toxicity and the urethral dose calculated from the dose-volume histogram (DVH) of HDR brachytherapy. Methods and Materials: Between September 2000 and December 2003, 70 patients with localized prostate cancer were treated by iridium-192 HDR brachytherapy combined with hypofractionated EBRT at the Gunma University Hospital. Hypofractionated EBRT was administered in fraction doses of 3 Gy, three times per week; a total dose of 51 Gy was delivered to the prostate gland and the seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography (TRUS)-guided HDR brachytherapy. The fraction size and the number of fractions in HDR brachytherapy were prospectively changed, whereas the total radiation dose for EBRT was fixed at 51 Gy. The fractionation in HDR brachytherapy was as follows: 5 Gy x 5, 7 Gy x 3, 9 Gy x 2, administered twice per day, although the biologic effective dose (BED) for HDR brachytherapy combined with EBRT, assuming that the α/β ratio is 3, was almost equal to 138 in each fractionation group. The planning target volume was defined as the prostate gland with 5-mm margin all around, and the planning was conducted based on

  2. ExternE: Externalities of energy Vol. 5. Nuclear

    International Nuclear Information System (INIS)

    Dreicer, M.; Tort, V.; Manen, P.

    1995-01-01

    Since the early 1970s, there has been increased interest in the environmental impacts that are caused by the generation of electricity. The comparative risk assessment studies at that time used mainly deaths and injuries as impact indicators. By the end of the 1980s studies changed to the assessment of the costs imposed on society and the environment that were not included in the market price of the energy produced, the so-called external costs. The preliminary studies that were published set the conceptual basis, grounded in neo-classical economics, for the valuation of the health and environmental impacts that could be assessed. As a consequence of the many questions raised by the methodologies employed by these early studies, Directorate General XII (DG XII) of the Commission of the European Communities established a collaborative research programme with the United States Department of Energy to identify an appropriate methodology for this type of work. Following the completion of this collaboration, the DG XII programme has continued as the ExternE project. The main objective of the work carried out at CEPN was to develop an impact pathway methodology for the nuclear fuel cycle that would be consistent with the methodologies developed for other fuel cycles, without loosing the nuclear-specific techniques required for a proper evaluation. In this way, comparisons between the different fuel cycles would be possible. This report presents the methodology and demonstration of the results in the context of the French nuclear fuel cycle. The United States team at Oak Ridge National Laboratory has previously issued a draft report on the results of their assessment. The French fuel cycle was broken down into 8 separate stages. Reference sites and 1990s technology were chosen to represent the total nuclear fuel cycle, as it exists today. In addition, the transportation of material between the sites was considered. The facilities are assessed for routine operation, except

  3. Accelerator for medical applications and electron acceleration by laser plasma

    International Nuclear Information System (INIS)

    Hosokai, Tomonao; Uesaka, Mitsuru

    2006-01-01

    In this article, the current status of radiation therapies in Japan and updated medical accelerators are reviewed. For medical use, there is a strong demand of a compact and flexible accelerator. At present, however, we have only two choices of the S-band linac with one or two rotation axis combined with the multi leaf collimator, or the X-band linac with a rather flexible robotic arm. In addition, the laser plasma cathode that is the second generation of the laser wake-field accelerator (LWFA) is studied as a high-quality electron source for medical use though it is still at the stage of the basic research. The potential of LWFA as medical accelerator near future is discussed based on updated results of laser plasma cathode experiment in Univ. of Tokyo. (author)

  4. Firm Search for External Knowledge

    DEFF Research Database (Denmark)

    Sofka, Wolfgang; Grimpe, Christoph

    2012-01-01

    ignored the institutional context that provides or denies access to external knowledge at the country level. Combining institutional and knowledge search theory, we suggest that the market orientation of the institutional environment and the magnitude of institutional change influence when firms begin......The innovation performance of modern firms is increasingly determined by their ability to search and absorb external knowledge. However, after a certain threshold firms "oversearch" their environment and innovation performance declines. In this paper, we argue that prior literature has largely...... to experience the negative performance effects of oversearch. Based on a comprehensive sample of almost 8,000 firms from ten European countries, we find that institutions matter considerably for firms' search activity. Higher market orientation of institutions increases the effectiveness of firms' search...

  5. Leveraging External Sources of Innovation

    DEFF Research Database (Denmark)

    West, Joel; Bogers, Marcel

    2014-01-01

    , it suggests a four-phase model in which a linear process—(1) obtaining, (2) integrating, and (3) commercializing external innovations—is combined with (4) interaction between the firm and its collaborators. This model is used to classify papers taken from the top 25 innovation journals, complemented by highly...... cited work beyond those journals. A review of 291 open innovation-related publications from these sources shows that the majority of these articles indeed address elements of this inbound open innovation process model. Specifically, it finds that researchers have front-loaded their examination...... external innovations create value rather than how firms capture value from those innovations. Finally, the interaction phase considers both feedback for the linear process and reciprocal innovation processes such as cocreation, network collaboration, and community innovation. This review and synthesis...

  6. Self-acceleration of relativistic modulated beams

    International Nuclear Information System (INIS)

    Ajzatskij, N.I.

    1989-01-01

    Unlike the case of self-acceleration of continuous beams, the self-acceleration of relativistic modulated beams requires the energy redistribution between the particles not at the period of excited oscillations but rather between the bunches. This may occur only in the case when the electron beam creates a multifrequency equilibrium state in the passive structure. In this case, there is a possibility for some bunches to be captured in the accelerating phase of the field without any external action. The authors have analyzed this possibility both theoretically and experimentally. 12 refs., 2 figs

  7. Sector ring accelerator ''RESATRON''

    International Nuclear Information System (INIS)

    Schwabe, E.

    1980-01-01

    Project of sector ring accelerator RESATRON is described. The curiosity of this accelerator is the second cycle of acceleration of the beam after stripping it on the foil. In such an accelerator heavy ions with a different ratio Z to A can be accelerated. (S.B.)

  8. Hybrid rail gun electromagnetic accelerators

    International Nuclear Information System (INIS)

    Chen, K.W.; Hachen, H.; Lee, A.; Legh, G.; Lin, T.; Mattay, S.; Wipf, S.

    1983-01-01

    Theoretical and experimental investigations on hybrid rail accelerators are presented. It is shown that the side surface areas and in some cases sabots of the projectile can be used to provide substantial amount of additional thrust. Moreover, it is shown that in most cases examined, external magnetic fields can be conveniently incorporated in the accelerator designs to supplement the rail-induced fields. Total thrusts in excess of 10 MN for kilogram-sized projectiles can in principle be established with driving currents of the order of 1 MA. No obvious stress limitations are foreseen. The percentages of thrust from external magnetic fields are sufficiently high that the use of which should be encouraged. The increased flexibility in the projectile shapes available permits the use of the proposed hybrid electromagnetic launcher technology in a variety of new areas, such as thrust boosts in conventional chemical rockets and other similar applications. Furthermore, the additional thrust obtained from the use of side surface areas greatly increases the maximum permissable thrust otherwise limited by material strength considerations. Thrust analyses for projectiles in several hybrid rail accelerator designs are discussed. Some laboratory experimental observations are presented

  9. [External cephalic version].

    Science.gov (United States)

    Navarro-Santana, B; Duarez-Coronado, M; Plaza-Arranz, J

    2016-08-01

    To analyze the rate of successful external cephalic versions in our center and caesarean sections that would be avoided with the use of external cephalic versions. From January 2012 to March 2016 external cephalic versions carried out at our center, which were a total of 52. We collected data about female age, gestational age at the time of the external cephalic version, maternal body mass index (BMI), fetal variety and situation, fetal weight, parity, location of the placenta, amniotic fluid index (ILA), tocolysis, analgesia, and newborn weight at birth, minor adverse effects (dizziness, hypotension and maternal pain) and major adverse effects (tachycardia, bradycardia, decelerations and emergency cesarean section). 45% of the versions were unsuccessful and 55% were successful. The percentage of successful vaginal delivery in versions was 84% (4% were instrumental) and 15% of caesarean sections. With respect to the variables studied, only significant differences in birth weight were found; suggesting that birth weight it is related to the outcome of external cephalic version. Probably we did not find significant differences due to the number of patients studied. For women with breech presentation, we recommend external cephalic version before the expectant management or performing a cesarean section. The external cephalic version increases the proportion of fetuses in cephalic presentation and also decreases the rate of caesarean sections.

  10. Piezosurgery in External Dacryocystorhinostomy.

    Science.gov (United States)

    Czyz, Craig N; Fowler, Amy M; Dutton, Jonathan J; Cahill, Kenneth V; Foster, Jill A; Hill, Robert H; Everman, Kelly R; Nabavi, Cameron B

    Dacryocystorhinostomy (DCR) can be performed via an external or endoscopic approach. The use of ultrasonic or piezosurgery has been well described for endoscopic DCRs but is lacking for external DCRs. This study presents a case series of external DCRs performed using piezosurgery evaluating results and complications. Prospective, consecutive case series of patients undergoing primary external DCR for lacrimal drainage insufficiency. A standard external DCR technique was used using 1 of 2 piezosurgery systems for all bone incision. All patients received silicone intubation to the lacrimal system. Surgical outcome was measured in terms of patient-reported epiphora as follows: 1) complete resolution, 2) improvement >50%, 3) improvement 50% improvement. There were 4 patients (7%) who had <50% improvement. There was 1 (2%) intraoperative complication and 2 (4%) postoperative complications recorded. Piezourgery is a viable modality for performing external DCRs. The lack of surgical complications shows a potential for decreased soft tissues damage. The surgical success rate based on patient-reported epiphora is similar to those published for mechanical external DCRs. This modality may benefit the novice surgeon in the reduction of soft and mucosal tissue damage.

  11. Multiperiodic accelerator structures for linear particle accelerators

    International Nuclear Information System (INIS)

    Tran, D.T.

    1975-01-01

    High efficiency linear accelerator structures, comprised of a succession of cylindrical resonant cavities for acceleration, are described. Coupling annular cavities are located at the periphery, each being coupled to two adjacent cylindrical cavities. (auth)

  12. Hydropower externalities: A meta-analysis

    International Nuclear Information System (INIS)

    Mattmann, Matteo; Logar, Ivana; Brouwer, Roy

    2016-01-01

    This paper presents a meta-analysis of existing research related to the economic valuation of the external effects of hydropower. A database consisting of 81 observations derived from 29 studies valuing the non-market impacts of hydropower electricity generation is constructed with the main aim to quantify and explain the economic values for positive and negative hydropower externalities. Different meta-regression model specifications are used to test the robustness of significant determinants of non-market values, including different types of hydropower impacts. The explanatory and predictive power of the estimated models is relatively high. Whilst controlling for sample and study characteristics, we find significant evidence for public aversion towards deteriorations of landscape, vegetation and wildlife caused by hydropower projects. There is however only weak evidence of willingness to pay for mitigating these effects. The main positive externality of hydropower generation, the avoidance of greenhouse gas emission, positively influences welfare estimates when combined with the share of hydropower in national energy production. Sensitivity to scope is detected, but not linked to specific externalities or non-market valuation methods. - Highlights: • A global meta-analysis of valuation studies of hydropower externalities is presented. • Positive and negative externalities are distinguished. • Welfare losses due to environmental deteriorations outweigh gains of GHG reductions. • There is only weak evidence of public WTP for mitigating negative externalities. • The non-market values of hydropower externalities are sensitive to scope.

  13. High-dose-rate intracavitary brachytherapy combined with external beam radiotherapy for stage IIIb adenocarcinoma of the uterine cervix in Japan. A multi-institutional study of Japanese Society of Therapeutic Radiology and Oncology 2006-2007 (Study of JASTRO 2006-2007)

    International Nuclear Information System (INIS)

    Niibe, Yuzuru; Kenjo, Masahiro; Onishi, Hiroshi

    2010-01-01

    The current study was a retrospective questionnaire survey of stage IIIb adenocarcinoma of the uterine cervix treated with high-dose-rate intracavitary brachytherapy combined with external beam radiation therapy in Japan aimed to investigate the optimal dose on the basis of the biological effective dose and prognostic factors. Between 1990 and 2000, 61 patients with stage IIIb adenocarcinoma of the uterine cervix underwent high-dose-rate intracavitary brachytherapy combined with external beam radiation therapy in 19 major hospitals in Japan. This retrospective questionnaire survey was performed by mail including survey charts to be fulfilled by radiation oncologists in these 19 major hospital. Fifty had only adenocarcinoma components and 11 had adenosquamous cell carcinoma components. All patients were treated with high-dose-rate intracavitary brachytherapy combined with external beam radiation therapy. Total biological effective dose (T-BED 10 ) was calculated from the sum of the biological effective doses of the external beam radiation therapy and the intracavitary brachytherapy. Thirty-two patients underwent chemotherapy. The 5-year overall survival rate of all patients was 20.2%. Stratified by total biological effective dose, the 5-year overall survival rate was 0% for T-BED 10 10 between 75 and 100 Gy and 0% for T-BED 10 >110 Gy (P=0.15). Stratified by histopathology, the 5-year overall survival rate was 22.1% for adenocarcinoma and 13.6% for adenosquamous cell carcinoma (P=0.43). Stratified by chemotherapy, the 5-year overall survival rate was 20.3% in patients who received chemotherapy and 20.4% in patients who did not receive chemotherapy (P=0.96). The 5-year overall survival rate of stage IIIb adenocarcinoma of the uterine cervix in this retrospective questionnaire survey was 20.2%. The optimal T-BED 10 and evident prognostic factors were not clear from this questionnaire survey. (author)

  14. Multi-beam linear accelerator EVT

    Energy Technology Data Exchange (ETDEWEB)

    Teryaev, Vladimir E., E-mail: vladimir_teryaev@mail.ru [Omega-P, Inc., New Haven, CT 06510 (United States); Kazakov, Sergey Yu. [Fermilab, Batavia, IL 60510 (United States); Hirshfield, Jay L. [Omega-P, Inc., New Haven, CT 06510 (United States); Yale University, New Haven, CT 06511 (United States)

    2016-09-01

    A novel electron multi-beam accelerator is presented. The accelerator, short-named EVT (Electron Voltage Transformer) belongs to the class of two-beam accelerators. It combines an RF generator and essentially an accelerator within the same vacuum envelope. Drive beam-lets and an accelerated beam are modulated in RF modulators and then bunches pass into an accelerating structure, comprising uncoupled with each other and inductive tuned cavities, where the energy transfer from the drive beams to the accelerated beam occurs. A phasing of bunches is solved by choice correspond distances between gaps of the adjacent cavities. Preliminary results of numerical simulations and the initial specification of EVT operating in S-band, with a 60 kV gun and generating a 2.7 A, 1.1 MV beam at its output is presented. A relatively high efficiency of 67% and high design average power suggest that EVT can find its use in industrial applications.

  15. Accelerators of atomic particles

    International Nuclear Information System (INIS)

    Sarancev, V.

    1975-01-01

    A brief survey is presented of accelerators and methods of accelerating elementary particles. The principle of collective accelerating of elementary particles is clarified and the problems are discussed of its realization. (B.S.)

  16. Quantum random walks using quantum accelerator modes

    International Nuclear Information System (INIS)

    Ma, Z.-Y.; Burnett, K.; D'Arcy, M. B.; Gardiner, S. A.

    2006-01-01

    We discuss the use of high-order quantum accelerator modes to achieve an atom optical realization of a biased quantum random walk. We first discuss how one can create coexistent quantum accelerator modes, and hence how momentum transfer that depends on the atoms' internal state can be achieved. When combined with microwave driving of the transition between the states, a different type of atomic beam splitter results. This permits the realization of a biased quantum random walk through quantum accelerator modes

  17. Automated External Defibrillator

    Science.gov (United States)

    ... leads to a 10 percent reduction in survival. Training To Use an Automated External Defibrillator Learning how to use an AED and taking a CPR (cardiopulmonary resuscitation) course are helpful. However, if trained ...

  18. Energy policy and externalities

    International Nuclear Information System (INIS)

    Bertel, E.; Fraser, P.

    2002-01-01

    External costs of energy have been assessed in a number of authoritative and reliable studies based upon widely accepted methodologies such as life cycle analysis (LCA). However, although those costs are recognised by most stakeholders and decision makers, results from analytical work on externalities and LCA studies are seldom used in policy making. The International Energy Agency (IEA) and the Nuclear Energy Agency (NEA) convened a joint workshop in November 2001 to offer experts and policy makers an opportunity to present state-of-the-art results from analytical work on externalities and debate issues related to the relevance of external costs and LCA for policy-making purposes. The findings from the workshop highlight the need for further work in the field and the potential rote of international organisations like the IEA and the NEA in this context. (authors)

  19. Externally Verifiable Oblivious RAM

    Directory of Open Access Journals (Sweden)

    Gancher Joshua

    2017-04-01

    Full Text Available We present the idea of externally verifiable oblivious RAM (ORAM. Our goal is to allow a client and server carrying out an ORAM protocol to have disputes adjudicated by a third party, allowing for the enforcement of penalties against an unreliable or malicious server. We give a security definition that guarantees protection not only against a malicious server but also against a client making false accusations. We then give modifications of the Path ORAM [15] and Ring ORAM [9] protocols that meet this security definition. These protocols both have the same asymptotic runtimes as the semi-honest original versions and require the external verifier to be involved only when the client or server deviates from the protocol. Finally, we implement externally verified ORAM, along with an automated cryptocurrency contract to use as the external verifier.

  20. Accelerator structure development for NLC

    International Nuclear Information System (INIS)

    Hoag, H.A.; Deruyter, H.; Pearson, C.; Ruth, R.D.; Wang, J.W.; Schaefer, J.

    1993-04-01

    In the program of work directed towards the development of an X-Band Next Linear Collider accelerator structure, two different test accelerator sections have been completed, and a third is being fabricated. The first is a simple 30-cell constant-impedance section in which no special attention was given to surface finish, pumping, and alignment. The second is an 86-cell section in which the cells were precision diamond-turned by Texas Instruments Inc. The structure has internal water-cooling and vacuum pumping manifolds. Some design details are given for the third section, which is a 206-cell structure with cavities dimensioned to give a Gaussian distribution of dipole mode frequencies. It has conventional-machining surface finishes and external water and pumping manifolds. Component design, fabrication, and assembly brazing are described for the first two experimental sections

  1. Source-to-accelerator quadrupole matching section for a compact linear accelerator

    Science.gov (United States)

    Seidl, P. A.; Persaud, A.; Ghiorso, W.; Ji, Q.; Waldron, W. L.; Lal, A.; Vinayakumar, K. B.; Schenkel, T.

    2018-05-01

    Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure: a matching section between the ion source extraction grids and the RF-acceleration unit and electrostatic focusing quadrupoles between successive acceleration units. The matching section consists of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture more beam current and to match the beam envelope to conditions for stable transport in an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.

  2. Scattering of accelerated wave packets

    Science.gov (United States)

    Longhi, S.; Horsley, S. A. R.; Della Valle, G.

    2018-03-01

    Wave-packet scattering from a stationary potential is significantly modified when the wave packet is subject to an external time-dependent force during the interaction. In the semiclassical limit, wave-packet motion is simply described by Newtonian equations, and the external force can, for example, cancel the potential force, making a potential barrier transparent. Here we consider wave-packet scattering from reflectionless potentials, where in general the potential becomes reflective when probed by an accelerated wave packet. In the particular case of the recently introduced class of complex Kramers-Kronig potentials we show that a broad class of time-dependent forces can be applied without inducing any scattering, while there is a breakdown of the reflectionless property when there is a broadband distribution of initial particle momentum, involving both positive and negative components.

  3. Test accelerator for linear collider

    International Nuclear Information System (INIS)

    Takeda, S.; Akai, K.; Akemoto, M.; Araki, S.; Hayano, H.; Hugo, T.; Ishihara, N.; Kawamoto, T.; Kimura, Y.; Kobayashi, H.; Kubo, T.; Kurokawa, S.; Matsumoto, H.; Mizuno, H.; Odagiri, J.; Otake, Y.; Sakai, H.; Shidara, T.; Shintake, T.; Suetake, M.; Takashima, T.; Takata, K.; Takeuchi, Y.; Urakawa, J.; Yamamoto, N.; Yokoya, K.; Yoshida, M.; Yoshioka, M.; Yamaoka, Y.

    1989-01-01

    KEK has proposed to build Test Accelerator Facility (TAF) capable of producing a 2.5 GeV electron beam for the purpose of stimulating R ampersand D for linear collider in TeV region. The TAF consists of a 1.5 GeV S-band linear accelerator, 1.5 GeV damping ring and 1.0 GeV X-band linear accelerator. The TAF project will be carried forward in three phases. Through Phase-I and Phase-II, the S-band and X-band linacs will be constructed, and in Phase-III, the damping ring will be completed. The construction of TAF Phase-I has started, and the 0.2 GeV S-band injector linac has been almost completed. The Phase-I linac is composed of a 240 keV electron gun, subharmonic bunchers, prebunchers and traveling buncher followed by high-gradient accelerating structures. The SLAC 5045 klystrons are driven at 450 kV in order to obtain the rf-power of 100 MW in a 1 μs pulse duration. The rf-power from a pair of klystrons are combined into an accelerating structure. The accelerating gradient up to 100 MeV/m will be obtained in a 0.6 m long structure. 5 refs., 3 figs., 2 tabs

  4. Plasma based charged-particle accelerators

    International Nuclear Information System (INIS)

    Bingham, R; Mendonca, J T; Shukla, P K

    2004-01-01

    Studies of charged-particle acceleration processes remain one of the most important areas of research in laboratory, space and astrophysical plasmas. In this paper, we present the underlying physics and the present status of high gradient and high energy plasma accelerators. We will focus on the acceleration of charged particles to relativistic energies by plasma waves that are created by intense laser and particle beams. The generation of relativistic plasma waves by intense lasers or electron beams in plasmas is important in the quest for producing ultra-high acceleration gradients for accelerators. With the development of compact short pulse high brightness lasers and electron positron beams, new areas of studies for laser/particle beam-matter interactions is opening up. A number of methods are being pursued vigorously to achieve ultra-high acceleration gradients. These include the plasma beat wave accelerator mechanism, which uses conventional long pulse (∼100 ps) modest intensity lasers (I ∼ 10 14 -10 16 W cm -2 ), the laser wakefield accelerator (LWFA), which uses the new breed of compact high brightness lasers ( 10 18 W cm -2 , the self-modulated LWFA concept, which combines elements of stimulated Raman forward scattering, and electron acceleration by nonlinear plasma waves excited by relativistic electron and positron bunches. In the ultra-high intensity regime, laser/particle beam-plasma interactions are highly nonlinear and relativistic, leading to new phenomena such as the plasma wakefield excitation for particle acceleration, relativistic self-focusing and guiding of laser beams, high-harmonic generation, acceleration of electrons, positrons, protons and photons. Fields greater than 1 GV cm -1 have been generated with particles being accelerated to 200 MeV over a distance of millimetre. Plasma wakefields driven by positron beams at the Stanford Linear Accelerator Center facility have accelerated the tail of the positron beam. In the near future

  5. Accelerator and Fusion Research Division. Annual report, October 1977--September 1978

    Energy Technology Data Exchange (ETDEWEB)

    1979-04-01

    Research is reported for the combined groups consisting of the Accelerator Division and the Magnetic Fusion Energy Group. Major topics reported include accelerator operations, magnetic fusion energy, and advanced accelerator development. (GHT)

  6. TeV/m Nano-Accelerator: Current Status of CNT-Channeling Acceleration Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Min [Northern Illinois U.; Lumpkin, Alex H. [Fermilab; Thangaraj, Jayakar Charles [Fermilab; Thurman-Keup, Randy Michael [Fermilab; Shiltsev, Vladimir D. [Fermilab

    2014-09-17

    Crystal channeling technology has offered various opportunities in the accelerator community with a viability of ultrahigh gradient (TV/m) acceleration for future HEP collider. The major challenge of channeling acceleration is that ultimate acceleration gradients might require a high power driver in the hard x-ray regime (~ 40 keV). This x-ray energy exceeds those for x-rays as of today, although x-ray lasers can efficiently excite solid plasma and accelerate particles inside a crystal channel. Moreover, only disposable crystal accelerators are possible at such high externally excited fields which would exceed the ionization thresholds destroying the atomic structure, so acceleration will take place only in a short time before full dissociation of the lattice. Carbon-based nanostructures have great potential with a wide range of flexibility and superior physical strength, which can be applied to channeling acceleration. This paper presents a beam- driven channeling acceleration concept with CNTs and discusses feasible experiments with the Advanced Superconducting Test Accelerator (ASTA) in Fermilab.

  7. Phase space linearization and external injection of electron bunches into laser-driven plasma wakefields at REGAE

    International Nuclear Information System (INIS)

    Zeitler, Benno Michael Georg

    2017-01-01

    beam control achievable in conventional electron sources is combined with the huge gradients of a plasma booster stage. In this thesis, the concept of the external injection experiment at REGAE is presented. The physical foundations are illustrated and combined into an extensive start-to-end design study. Using the key constraints from this results, the required beam line design is developed. An injection into a plasma wave with the aim of diagnosing the accelerating field inevitably requires electron bunches which are much shorter then the period of the plasma wavelength. This reference length is typically on the order of a few ten microns. The conventionally accelerated particle distribution must therefore be compressed. At REGAE the so-called ballistic bunching scheme is applied, leading to bunches with a longitudinal extent of about 3 μm. Even better results can be obtained if nonlinearities arising in the compression are compensated. A novel method to achieve this, based on the controlled beam expansion, is the stretcher mode. It is developed and described in detail in the second part of this thesis. Simulations that verify the analytic model presented in the thesis suggest a possible decrease in bunch length by a factor of ten and more compared to the design parameters of REGAE. Electron bunch lengths below 300 nm, i.e., below one femtosecond (1 fs=10"-"1"5 s) duration, can be produced. In addition, an energy spread compensation leading to quasi mono-energetic beams can be achieved by this method. Importantly, the approach is not restricted to Regae or similar machines, but can be generalized to a variety of accelerators.

  8. Phase space linearization and external injection of electron bunches into laser-driven plasma wakefields at REGAE

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, Benno Michael Georg [Hamburg Univ. (Germany). Fakultaet fuer Mathematik, Informatik und Naturwissenschaften

    2017-01-15

    beam control achievable in conventional electron sources is combined with the huge gradients of a plasma booster stage. In this thesis, the concept of the external injection experiment at REGAE is presented. The physical foundations are illustrated and combined into an extensive start-to-end design study. Using the key constraints from this results, the required beam line design is developed. An injection into a plasma wave with the aim of diagnosing the accelerating field inevitably requires electron bunches which are much shorter then the period of the plasma wavelength. This reference length is typically on the order of a few ten microns. The conventionally accelerated particle distribution must therefore be compressed. At REGAE the so-called ballistic bunching scheme is applied, leading to bunches with a longitudinal extent of about 3 μm. Even better results can be obtained if nonlinearities arising in the compression are compensated. A novel method to achieve this, based on the controlled beam expansion, is the stretcher mode. It is developed and described in detail in the second part of this thesis. Simulations that verify the analytic model presented in the thesis suggest a possible decrease in bunch length by a factor of ten and more compared to the design parameters of REGAE. Electron bunch lengths below 300 nm, i.e., below one femtosecond (1 fs=10{sup -15} s) duration, can be produced. In addition, an energy spread compensation leading to quasi mono-energetic beams can be achieved by this method. Importantly, the approach is not restricted to Regae or similar machines, but can be generalized to a variety of accelerators.

  9. Accelerators of future generation

    International Nuclear Information System (INIS)

    Kolomenskij, A.A.

    1983-01-01

    A brief review of the prospects of development of various of types accelerator over next 10 to 15 years is given. The following directions are considered: superhign energy proton accelerators and storage rings, electron-positron colliding beams, heavy ion accelerators, medium energy, high-current proton accelerators superhigh power particle beams (electrons light- and heavy ions) for inertial fusion

  10. Future accelerator technology

    International Nuclear Information System (INIS)

    Sessler, A.M.

    1986-05-01

    A general discussion is presented of the acceleration of particles. Upon this foundation is built a categorization scheme into which all accelerators can be placed. Special attention is devoted to accelerators which employ a wake-field mechanism and a restricting theorem is examined. It is shown how the theorem may be circumvented. Comments are made on various acceleration schemes

  11. Goal Management Training Combined With External Cuing as a Means to Improve Emotional Regulation, Psychological Functioning, and Quality of Life in Patients With Acquired Brain Injury: A Randomized Controlled Trial.

    Science.gov (United States)

    Tornås, Sveinung; Løvstad, Marianne; Solbakk, Anne-Kristin; Schanke, Anne-Kristine; Stubberud, Jan

    2016-11-01

    To investigate whether goal management training (GMT) expanded to include external cuing and an emotional regulation module is associated with improved emotional regulation, psychological functioning, and quality of life (QOL) after chronic acquired brain injury (ABI). Randomized controlled trial with blinded outcome assessment at baseline, posttraining, and 6-month follow-up. Outpatient. Persons with ABI and executive dysfunction (N=70; 64% traumatic brain injury; 52% men; mean age ± SD, 43±13y; mean time since injury ± SD, 8.1±9.4y). Eight sessions of GMT in groups, including a new module addressing emotional regulation, and external cuing. A psychoeducative control condition (Brain Health Workshop) was matched on amount of training, therapist contact, and homework. Emotional regulation was assessed with the Brain Injury Rehabilitation Trust Regulation of Emotions Questionnaire, the Emotional Control subscale and the Emotion Regulation factor (Behavior Rating Inventory of Executive Function-Adult Version), and the Positive and Negative Affect subscales from the Dysexecutive Questionnaire. Secondary outcome measures included psychological distress (Hopkins Symptom Checklist-25) and QOL (Quality of Life After Brain Injury Scale). Findings indicated beneficial effects of GMT on emotional regulation skills in everyday life and in QOL 6 months posttreatment. No intervention effects on measures of psychological distress were registered. GMT is a promising intervention for improving emotional regulation after ABI, even in the chronic phase. More research using objective measures of emotional regulation is needed to investigate the efficacy of this type of training. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. External stent for repair of secondary tracheomalacia.

    Science.gov (United States)

    Johnston, M R; Loeber, N; Hillyer, P; Stephenson, L W; Edmunds, L H

    1980-09-01

    Tracheomalacia was created in anesthetized piglets by submucosal resection of 3 to 5 tracheal cartilages. Measurements of airway pressure and flow showed that expiratory airway resistance is maximal at low lung volumes and is significantly increased by creation of the malacic segment. Cervical flexion increases expiratory airway resistance, whereas hyperextension of the neck reduces resistance toward normal. External stenting of the malacic segment reduces expiratory airway resistance, and the combination of external stenting and hyperextension restores airway resistance to normal except at low lung volume. Two patients with secondary tracheomalacia required tracheostomy and could not be decannulated after the indication for the tracheostomy was corrected. Both were successfully decannulated after external stenting of the malacic segment with rib grafts. Postoperative measurements of expiratory pulmonary resistance show a marked decrease from preoperative measurements. External stenting of symptomatic tracheomalacia reduces expiratory airway resistance by supporting and stretching the malacic segment and is preferable to prolonged internal stenting or tracheal resection.

  13. Malignant external otitis

    International Nuclear Information System (INIS)

    Dupuch, K.M.; Iryboz, T.; Firat, M.; Levy, C.; Tubiana, J.M.

    1991-01-01

    This paper illustrates the value of CT and MR in early diagnosis and spread of malignant external otitis. The authors retrospectively analyzed 15 patients with proved malignant external otitis examined with postcontrast high-resolution CT (15/15) and MR (6/15) (T1- and T2-weighting). Gallium studies were done in 6/15 patients. Early diagnosis was made when CT demonstrated a soft-tissue mass of the external auditory canal associated with scattered zones of cortical bone erosions (13/15). Spread of the disease was better delineated by MR than CT, especially skull base extension (6/15). Temporomandibular joint involvement with extension into parotid or/and masticator spaces 6/15 was as well detected with CT as with MR. If CT remains the first and best procedure for diagnosis, MR - despite its cost - appears a good procedure to depict exact anatomic spread, allowing therapeutic management

  14. Productivity Change and Externalities

    DEFF Research Database (Denmark)

    Kravtsova, Victoria

    2014-01-01

    This paper contributes to the analysis of the impact of externalities on the host country's total factor productivity by taking into account different dimensions of spillover effects. Namely, engagement in exporting and foreign ownership is generally perceived as being beneficial to individual...... firms and the economy as a whole. The approach used in the current research accounts for different internal as well as external factors that individual firms face and evaluates the effect on changes in productivity, technology as well as the efficiency of domestic firms. The empirical analysis focuses...... on Hungary. While the country leads the group of post-socialist countries in the amount of attracted foreign direct investments (FDI) the effect of this policy on the economy remains unclear. The research finds that different externalities play a different role in productivity, technological and efficiency...

  15. Externality or sustainability economics?

    International Nuclear Information System (INIS)

    Bergh, Jeroen C.J.M. van den

    2010-01-01

    In an effort to develop 'sustainability economics' Baumgaertner and Quaas (2010) neglect the central concept of environmental economics-'environmental externality'. This note proposes a possible connection between the concepts of environmental externality and sustainability. In addition, attention is asked for other aspects of 'sustainability economics', namely the distinction weak/strong sustainability, spatial sustainability and sustainable trade, distinctive sustainability policy, and the ideas of early 'sustainability economists'. I argue that both sustainability and externalities reflect a systems perspective and propose that effective sustainability solutions require that more attention is given to system feedbacks, notably other-regarding preferences and social interactions, and energy and environmental rebound. The case of climate change and policy is used to illustrate particular statements. As a conclusion, a list of 20 insights and suggestions for research is offered. (author)

  16. Metasurface external cavity laser

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Luyao, E-mail: luyaoxu.ee@ucla.edu; Curwen, Christopher A.; Williams, Benjamin S. [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); California NanoSystems Institute, University of California, Los Angeles, California 90095 (United States); Hon, Philip W. C.; Itoh, Tatsuo [Department of Electrical Engineering, University of California, Los Angeles, California 90095 (United States); Chen, Qi-Sheng [Northrop Grumman Aerospace Systems, Redondo Beach, California 90278 (United States)

    2015-11-30

    A vertical-external-cavity surface-emitting-laser is demonstrated in the terahertz range, which is based upon an amplifying metasurface reflector composed of a sub-wavelength array of antenna-coupled quantum-cascade sub-cavities. Lasing is possible when the metasurface reflector is placed into a low-loss external cavity such that the external cavity—not the sub-cavities—determines the beam properties. A near-Gaussian beam of 4.3° × 5.1° divergence is observed and an output power level >5 mW is achieved. The polarized response of the metasurface allows the use of a wire-grid polarizer as an output coupler that is continuously tunable.

  17. Randomized Phase III Trial to Test Accelerated Versus Standard Fractionation in Combination With Concurrent Cisplatin for Head and Neck Carcinomas in the Radiation Therapy Oncology Group 0129 Trial: Long-Term Report of Efficacy and Toxicity

    Science.gov (United States)

    Nguyen-Tan, Phuc Felix; Zhang, Qiang; Ang, K. Kian; Weber, Randal S.; Rosenthal, David I.; Soulieres, Denis; Kim, Harold; Silverman, Craig; Raben, Adam; Galloway, Thomas J.; Fortin, André; Gore, Elizabeth; Westra, William H.; Chung, Christine H.; Jordan, Richard C.; Gillison, Maura L.; List, Marcie; Le, Quynh-Thu

    2014-01-01

    Purpose We tested the efficacy and toxicity of cisplatin plus accelerated fractionation with a concomitant boost (AFX-C) versus standard fractionation (SFX) in locally advanced head and neck carcinoma (LA-HNC). Patients and Methods Patients had stage III to IV carcinoma of the oral cavity, oropharynx, hypopharynx, or larynx. Radiation therapy schedules were 70 Gy in 35 fractions over 7 weeks (SFX) or 72 Gy in 42 fractions over 6 weeks (AFX-C). Cisplatin doses were 100 mg/m2 once every 3 weeks for two (AFX-C) or three (SFX) cycles. Toxicities were scored by using National Cancer Institute Common Toxicity Criteria 2.0 and the Radiation Therapy Oncology Group/European Organisation for Research and Treatment of Cancer criteria. Overall survival (OS) and progression-free survival (PFS) rates were estimated by using the Kaplan-Meier method and were compared by using the one-sided log-rank test. Locoregional failure (LRF) and distant metastasis (DM) rates were estimated by using the cumulative incidence method and Gray's test. Results In all, 721 of 743 patients were analyzable (361, SFX; 360, AFX-C). At a median follow-up of 7.9 years (range, 0.3 to 10.1 years) for 355 surviving patients, no differences were observed in OS (hazard ratio [HR], 0.96; 95% CI, 0.79 to 1.18; P = .37; 8-year survival, 48% v 48%), PFS (HR, 1.02; 95% CI, 0.84 to 1.24; P = .52; 8-year estimate, 42% v 41%), LRF (HR, 1.08; 95% CI, 0.84 to 1.38; P = .78; 8-year estimate, 37% v 39%), or DM (HR, 0.83; 95% CI, 0.56 to 1.24; P = .16; 8-year estimate, 15% v 13%). For oropharyngeal cancer, p16-positive patients had better OS than p16-negative patients (HR, 0.30; 95% CI, 0.21 to 0.42; P < .001; 8-year survival, 70.9% v 30.2%). There were no statistically significant differences in the grade 3 to 5 acute or late toxicities between the two arms and p-16 status. Conclusion When combined with cisplatin, AFX-C neither improved outcome nor increased late toxicity in patients with LA-HNC. Long-term high survival

  18. The External Mind

    DEFF Research Database (Denmark)

    , Extended Mind and Distributed Cognition by Claudio Paolucci pp. 69-96 The Social Horizon of Embodied Language and Material Symbols by Riccardo Fusaroli pp. 97-123 Semiotics and Theories of Situated/Distributed Action and Cognition: a Dialogue and Many Intersections by Tommaso Granelli pp. 125-167 Building......The External Mind: an Introduction by Riccardo Fusaroli, Claudio Paolucci pp. 3-31 The sign of the Hand: Symbolic Practices and the Extended Mind by Massimiliano Cappuccio, Michael Wheeler pp. 33-55 The Overextended Mind by Shaun Gallagher pp. 57-68 The "External Mind": Semiotics, Pragmatism...

  19. Comparing joint kinematics and center of mass acceleration as feedback for control of standing balance by functional neuromuscular stimulation.

    Science.gov (United States)

    Nataraj, Raviraj; Audu, Musa L; Triolo, Ronald J

    2012-05-06

    The purpose of this study was to determine the comparative effectiveness of feedback control systems for maintaining standing balance based on joint kinematics or total body center of mass (COM) acceleration, and assess their clinical practicality for standing neuroprostheses after spinal cord injury (SCI). In simulation, controller performance was measured according to the upper extremity effort required to stabilize a three-dimensional model of bipedal standing against a variety of postural disturbances. Three cases were investigated: proportional-derivative control based on joint kinematics alone, COM acceleration feedback alone, and combined joint kinematics and COM acceleration feedback. Additionally, pilot data was collected during external perturbations of an individual with SCI standing with functional neuromuscular stimulation (FNS), and the resulting joint kinematics and COM acceleration data was analyzed. Compared to the baseline case of maximal constant muscle excitations, the three control systems reduced the mean upper extremity loading by 51%, 43% and 56%, respectively against external force-pulse perturbations. Controller robustness was defined as the degradation in performance with increasing levels of input errors expected with clinical deployment of sensor-based feedback. At error levels typical for body-mounted inertial sensors, performance degradation due to sensor noise and placement were negligible. However, at typical tracking error levels, performance could degrade as much as 86% for joint kinematics feedback and 35% for COM acceleration feedback. Pilot data indicated that COM acceleration could be estimated with a few well-placed sensors and efficiently captures information related to movement synergies observed during perturbed bipedal standing following SCI. Overall, COM acceleration feedback may be a more feasible solution for control of standing with FNS given its superior robustness and small number of inputs required.

  20. Comparing joint kinematics and center of mass acceleration as feedback for control of standing balance by functional neuromuscular stimulation

    Directory of Open Access Journals (Sweden)

    Nataraj Raviraj

    2012-05-01

    Full Text Available Abstract Background The purpose of this study was to determine the comparative effectiveness of feedback control systems for maintaining standing balance based on joint kinematics or total body center of mass (COM acceleration, and assess their clinical practicality for standing neuroprostheses after spinal cord injury (SCI. Methods In simulation, controller performance was measured according to the upper extremity effort required to stabilize a three-dimensional model of bipedal standing against a variety of postural disturbances. Three cases were investigated: proportional-derivative control based on joint kinematics alone, COM acceleration feedback alone, and combined joint kinematics and COM acceleration feedback. Additionally, pilot data was collected during external perturbations of an individual with SCI standing with functional neuromuscular stimulation (FNS, and the resulting joint kinematics and COM acceleration data was analyzed. Results Compared to the baseline case of maximal constant muscle excitations, the three control systems reduced the mean upper extremity loading by 51%, 43% and 56%, respectively against external force-pulse perturbations. Controller robustness was defined as the degradation in performance with increasing levels of input errors expected with clinical deployment of sensor-based feedback. At error levels typical for body-mounted inertial sensors, performance degradation due to sensor noise and placement were negligible. However, at typical tracking error levels, performance could degrade as much as 86% for joint kinematics feedback and 35% for COM acceleration feedback. Pilot data indicated that COM acceleration could be estimated with a few well-placed sensors and efficiently captures information related to movement synergies observed during perturbed bipedal standing following SCI. Conclusions Overall, COM acceleration feedback may be a more feasible solution for control of standing with FNS given its

  1. A high-current racetrack induction accelerator

    International Nuclear Information System (INIS)

    Mondelli, A.; Roberson, C.W.

    1983-01-01

    In this paper, the energy and system scaling laws of the Racetrack Induction Accelerator are determined and its operating principles are discussed. This device is a cyclic accelerator that is capable of multi-kiloamp operation. Long pulse induction linac technology is used to obtain short acceleration times. The accelerator consists of a long-pulse linear induction module and a racetrack beam transport system. For detailed studies of the particle dynamics in a racetrack, a numerical model is required to integrate the fully-relativistic single-particle equations of motion in an externally applied magnetic field. The numerical model is a compromise between the need for a large rotational transform and the need for a reasonable volume within the separatrix

  2. A study of reflex tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Takao; Morinobu, Shunpei; Gono, Yasuyuki; Sagara, Kenji; Sugimitsu, Tsuyoshi; Mitarai, Shiro; Nakamura, Hiroyuki; Ikeda, Nobuo; Morikawa, Tsuneyasu [Kyushu Univ., Fukuoka (Japan). Faculty of Science

    1996-12-01

    An investigation on `developing research theme and its realizing experimental apparatus` based on the tandem accelerator facility is executed. At a standpoint of recognition on essentiality of preparation, improvement or novel technical development capable of extreme increase in capacity of the tandem accelerator facility to form COE with high uniqueness, proposal of numerous ideas and their investigations and searches were conducted. In this paper, consideration results of `beam reacceleration using tandem accelerator` were shown as follows: (1) Short life unstable nuclei formed by nuclear reaction using tandem acceleration primary beam is ionized to negative and to reaccelerate by using the same tandem accelerator. And (2) by combination of plural electrons with the tandem primary accelerated beam, numbers of charge is reduced to reaccelerate by the tandem. (G.K.)

  3. An Accelerator control middle layer using Matlab

    CERN Document Server

    Portmann, G J; Terebilo, Andrei

    2005-01-01

    Matlab is a matrix manipulation language originally developed to be a convenient language for using the LINPACK and EISPACK libraries. What makes Matlab so appealing for accelerator physics is the combination of a matrix oriented programming language, an active workspace for system variables, powerful graphics capability, built-in math libraries, and platform independence. A number of software toolboxes for accelerators have been written in Matlab – the Accelerator Toolbox (AT) for machine simulations, LOCO for accelerator calibration, Matlab Channel Access Toolbox (MCA) for EPICS connections, and the Middle Layer. This paper will describe the MiddleLayer software toolbox that resides between the high-level control applications and the low-level accelerator control system. This software was a collaborative effort between ALS and Spear but was written to easily port. Five accelerators presently use this software – Spear, ALS, CLS, and the X-ray and VUV rings at Brookhaven. The Middle Layer fu...

  4. Accelerating cosmologies from exponential potentials

    International Nuclear Information System (INIS)

    Neupane, Ishwaree P.

    2003-11-01

    It is learnt that exponential potentials of the form V ∼ exp(-2cφ/M p ) arising from the hyperbolic or flux compactification of higher-dimensional theories are of interest for getting short periods of accelerated cosmological expansions. Using a similar potential but derived for the combined case of hyperbolic-flux compactification, we study a four-dimensional flat (or open) FRW cosmologies and give analytic (and numerical) solutions with exponential behavior of scale factors. We show that, for the M-theory motivated potentials, the cosmic acceleration of the universe can be eternal if the spatial curvature of the 4d spacetime is negative, while the acceleration is only transient for a spatially flat universe. We also briefly discuss about the mass of massive Kaluza-Klein modes and the dynamical stabilization of the compact hyperbolic extra dimensions. (author)

  5. Externalities - an analysis using the EU ExternE-results

    International Nuclear Information System (INIS)

    2003-10-01

    The EU project ExternE quantified the externalities for the different energy technologies. In this work, the ExternE results are used in a MARKAL-analysis for the Nordic countries. The analysis does not go into detail, but gives some interesting indications: The external costs are not fully covered in the Nordic energy systems, the present taxes and charges are not high enough. The emissions from the energy systems would be strongly reduced, if taxes/environmental charges were set at the level ExternE calculate. The emissions from power production would be reduced most. Renewable energy sources and natural gas dominate the energy systems in the ExternE case

  6. Radiative damping in plasma-based accelerators

    Directory of Open Access Journals (Sweden)

    I. Yu. Kostyukov

    2012-11-01

    Full Text Available The electrons accelerated in a plasma-based accelerator undergo betatron oscillations and emit synchrotron radiation. The energy loss to synchrotron radiation may seriously affect electron acceleration. The electron dynamics under combined influence of the constant accelerating force and the classical radiation reaction force is studied. It is shown that electron acceleration cannot be limited by radiation reaction. If initially the accelerating force was stronger than the radiation reaction force, then the electron acceleration is unlimited. Otherwise the electron is decelerated by radiative damping up to a certain instant of time and then accelerated without limits. It is shown that regardless of the initial conditions the infinite-time asymptotic behavior of an electron is governed by a self-similar solution providing that the radiative damping becomes exactly equal to 2/3 of the accelerating force. The relative energy spread induced by the radiative damping decreases with time in the infinite-time limit. The multistage schemes operating in the asymptotic acceleration regime when electron dynamics is determined by the radiation reaction are discussed.

  7. External costs of electricity

    International Nuclear Information System (INIS)

    Rabl, A.; Spadaro, J.V.

    2005-01-01

    This article presents a synthesis of the ExternE project (External costs of Energy) of the European community about the external costs of power generation. Pollution impacts are calculated using an 'impact pathways' analysis, i.e. an analysis of the emission - dispersion - dose-response function - cost evaluation chain. Results are presented for different fuel cycles (with several technological variants) with their confidence intervals. The environmental impact costs are particularly high for coal: for instance, in France, for coal-fired power plants it is of the same order as the electricity retail price. For natural gas, this cost is about a third of the one for coal. On the contrary, the environmental impact costs for nuclear and renewable energies are low, typically of few per cent of the electricity price. The main part of these costs corresponds to the sanitary impacts, in particular the untimely mortality. In order to avoid any controversy about the cost evaluation of mortality, the reduction of the expectation of life due to the different fuel cycles is also indicated and the risks linked with nuclear energy are presented using several comparisons. (J.S.)

  8. On parabolic external maps

    DEFF Research Database (Denmark)

    Lomonaco, Luna; Petersen, Carsten Lunde; Shen, Weixiao

    2017-01-01

    We prove that any C1+BV degree d ≥ 2 circle covering h having all periodic orbits weakly expanding, is conjugate by a C1+BV diffeomorphism to a metrically expanding map. We use this to connect the space of parabolic external maps (coming from the theory of parabolic-like maps) to metrically expan...

  9. Stochastic Control - External Models

    DEFF Research Database (Denmark)

    Poulsen, Niels Kjølstad

    2005-01-01

    This note is devoted to control of stochastic systems described in discrete time. We are concerned with external descriptions or transfer function model, where we have a dynamic model for the input output relation only (i.e.. no direct internal information). The methods are based on LTI systems...

  10. Evaluation of a new method of RF power coupling to acceleration cavity of charged particles accelerators

    Directory of Open Access Journals (Sweden)

    A M Poursaleh

    2017-08-01

    Full Text Available In this paper, the feasibility studty of a new method of RF power coupling to acceleration cavity of charged particles accelerator will be evaluated. In this method a slit is created around the accelerator cavity, and RF power amplifier modules is connected directly to the acceleration cavity. In fact, in this design, the cavity in addition to acting as an acceleration cavity, acts as a RF power combiner. The benefits of this method are avoiding the use of RF vacuum tubes, transmission lines, high power combiner and coupler. In this research, cylindrical and coaxial cavities were studied, and a small sample coaxial cavity is build by this method. The results of the resarch showed that compact, economical and safe RF accelerators can be achieved by the proposed method

  11. 14 CFR 29.865 - External loads.

    Science.gov (United States)

    2010-01-01

    ... 200 volts per meter. (iii) Be protected against any failure that could be induced by a failure mode of... operational envelope without hazard to the rotorcraft during normal flight conditions. In addition, these...-load combinations to be used for nonhuman external cargo except for the failure of critical structural...

  12. Immediate and long-term effects in the hematopoietic system and the morphology of the respiratory system in experimental animals under chronic combined action of external gamma exposure and inhalation exposure.

    Science.gov (United States)

    Tatarkin, Sergey; Moukhamedieva, Lana; Aleksandr, Shafirkin; Barantseva, Maria; Ivanova, Svetlana

    The need to solve hygiene problems valuation of environmental factors in the implementation of the projected manned interplanetary missions, determined the relevance of studying the effect of external gamma-irradiation with inhalation of mixtures of chemicals on the parameters of major critical body systems: hematopoiesis and respiratory (morphological and morphometric parameters) in the short and long periods. The study conducted on 504 male mice F1 (CBA × C57BL6) under chronic fractional gamma-irradiation (within 10 weeks at a total dose 350sGr) and then under inhalation by mixtures of chemicals in low concentrations. Duration of the experiment (124 days) and 90 -day recovery period. Displaying adaptive reorganization in hematopoietic system, which was characterized by a tension of regulatory systems of animals and by a proliferation of bone marrow cells and by dynamic changes in amount of lymphoid cells in peripheral blood, elevated levels of the antioxidant activity of red blood cells, and morphological manifestations of "incomplete recovery " of the spleen, which are retained in the recovery period. Morphological changes in the respiratory organs of animals testified about immunogenesis activation and development of structural changes as a chronic inflammatory process. Increase of fibrous connective tissue in the walls of the trachea, bronchus and lung, against reduction of loose fibrous connective tissue (more pronounced in respiratory parts of the respiratory system) in experimental animals, which may indicate a reduction of the functional reserves of the body and increase the risk of adverse long-term effects.

  13. Basis of medical accelerator. Synchrotron

    International Nuclear Information System (INIS)

    Kawachi, Kiyomitsu

    2014-01-01

    On the synchrotron as a medical accelerator, this paper introduces the basic principle, basic techniques and the like. The accelerator, when synchrotron is adopted as an ion beam radiotherapy system, is the composite accelerator composed of ion sources, injector, and synchrotron. This paper introduces the overall structure of synchrotron, and conceptually explains the basic behavior of high-frequency waves and magnetic field of synchrotron, as well as the deflection electromagnet of medical synchrotron and the operation pattern of high-frequency acceleration system. The types of synchrotron can be classified to the function combination type and function separation type, and this paper introduces the features of each type and various types of synchrotrons. It also explains beam dynamics important for ensuring the stability of beams, with a focus on the coordinate system, vertical movement, and lateral movement. In addition, it explains the incidence and outgoing of beams that are important for properly operating the accelerator, with a focus on their techniques. (A.O.)

  14. Optimization of negative ion accelerators

    International Nuclear Information System (INIS)

    Pamela, J.

    1991-01-01

    We have started to study negative ion extraction and acceleration systems in view of designing a 1 MeV D - accelerator. This study is being made with a two-Dimensional code that has been specifically developed in our laboratory and validated by comparison to three sets of experimental data. We believe that the criteria for negative ion accelerator design optimization should be: (i) to provide the best optics; (ii) to reduce the power load on the extraction grid; (iii) to allow operation with low electric fields in order to reduce the problem of breakdowns. We show some results of optics calculations performed for two systems that will be operational in the next months: the CEA-JAERI collaboration at Cadarache and the european DRAGON experiment at Culham. Extrapolations to higher energies of 500 to 1100 keV have also been conducted. All results indicate that the overall accelerator length, whatever be the number of gaps, is constrained by space charge effects (Child-Langmuir). We have combined this constraint with high-voltage hold-off empirical laws. As a result, it appears that accelerating 10 mA/cm 2 of D - at 1 MeV with good optics, as required for NET or ITER, is close to the expected limit of high-voltage hold-off

  15. Experimental validation of a radio frequency photogun as external electron

    NARCIS (Netherlands)

    Stragier, X.F.D.; Luiten, O.J.; Geer, van der S.B.; Wiel, van der M.J.

    2011-01-01

    A purpose-built RF-photogun as external electron injector for a laser wakefield accelerator has been thoroughly tested. Different properties of the RF-photogun have been measured such as energy, energy spread and transverse emittance. The focus of this study is the investigation of the smallest

  16. Estimating location without external cues.

    Directory of Open Access Journals (Sweden)

    Allen Cheung

    2014-10-01

    Full Text Available The ability to determine one's location is fundamental to spatial navigation. Here, it is shown that localization is theoretically possible without the use of external cues, and without knowledge of initial position or orientation. With only error-prone self-motion estimates as input, a fully disoriented agent can, in principle, determine its location in familiar spaces with 1-fold rotational symmetry. Surprisingly, localization does not require the sensing of any external cue, including the boundary. The combination of self-motion estimates and an internal map of the arena provide enough information for localization. This stands in conflict with the supposition that 2D arenas are analogous to open fields. Using a rodent error model, it is shown that the localization performance which can be achieved is enough to initiate and maintain stable firing patterns like those of grid cells, starting from full disorientation. Successful localization was achieved when the rotational asymmetry was due to the external boundary, an interior barrier or a void space within an arena. Optimal localization performance was found to depend on arena shape, arena size, local and global rotational asymmetry, and the structure of the path taken during localization. Since allothetic cues including visual and boundary contact cues were not present, localization necessarily relied on the fusion of idiothetic self-motion cues and memory of the boundary. Implications for spatial navigation mechanisms are discussed, including possible relationships with place field overdispersion and hippocampal reverse replay. Based on these results, experiments are suggested to identify if and where information fusion occurs in the mammalian spatial memory system.

  17. 2014 CERN Accelerator Schools: Plasma Wake Acceleration

    CERN Multimedia

    2014-01-01

    A specialised school on Plasma Wake Acceleration will be held at CERN, Switzerland from 23-29 November, 2014.   This course will be of interest to staff and students in accelerator laboratories, university departments and companies working in or having an interest in the field of new acceleration techniques. Following introductory lectures on plasma and laser physics, the course will cover the different components of a plasma wake accelerator and plasma beam systems. An overview of the experimental studies, diagnostic tools and state of the art wake acceleration facilities, both present and planned, will complement the theoretical part. Topical seminars and a visit of CERN will complete the programme. Further information can be found at: http://cas.web.cern.ch/cas/PlasmaWake2014/CERN-advert.html http://indico.cern.ch/event/285444/

  18. Accelerator research studies. Progress report

    International Nuclear Information System (INIS)

    1984-06-01

    Progress is reported in both experimental studies as well as theoretical understanding of the beam transport problem. Major highlights are: (a) the completion of the first channel section with 12 periods and two matching solenoids, (b) measurements of beam transmission and emittance in this 12-lens channel, (c) extensive analytical and numerical studies of the beam transport problem in collaboration with GSI (W. Germany), (d) detailed measurements and calculations of beam propagation through one lens with spherical aberration and space charge, and (e) completion of the emittance grids at the Rutherford-Appleton Laboratory. Our main objectives in Task B of our research program are: (a) study of collective acceleration of positive ions from a localized plasma source by an intense relativistic electron beam (IREB), (b) external control of the IREB beam front by a slow-wave structure to achieve higher ion energies - the Beam Front Accelerator (BFA) concept, (c) study of ion and electron acceleration and other applications of a plasma focus device, and (d) theoretical studies in support of (a) and (b). Our research in these areas has been oriented towards obtaining an improved understanding of the physical processes at work in these experiments and, subsequently, achieving improved performance for specific potential applications

  19. Acceleration of black hole universe

    Science.gov (United States)

    Zhang, T. X.; Frederick, C.

    2014-01-01

    Recently, Zhang slightly modified the standard big bang theory and developed a new cosmological model called black hole universe, which is consistent with Mach's principle, governed by Einstein's general theory of relativity, and able to explain all observations of the universe. Previous studies accounted for the origin, structure, evolution, expansion, and cosmic microwave background radiation of the black hole universe, which grew from a star-like black hole with several solar masses through a supermassive black hole with billions of solar masses to the present state with hundred billion-trillions of solar masses by accreting ambient matter and merging with other black holes. This paper investigates acceleration of the black hole universe and provides an alternative explanation for the redshift and luminosity distance measurements of type Ia supernovae. The results indicate that the black hole universe accelerates its expansion when it accretes the ambient matter in an increasing rate. In other words, i.e., when the second-order derivative of the mass of the black hole universe with respect to the time is positive . For a constant deceleration parameter , we can perfectly explain the type Ia supernova measurements with the reduced chi-square to be very close to unity, χ red˜1.0012. The expansion and acceleration of black hole universe are driven by external energy.

  20. ExternE transport methodology for external cost evaluation of air pollution

    DEFF Research Database (Denmark)

    Jensen, S. S.; Berkowicz, R.; Brandt, J.

    The report describes how the human exposure estimates based on NERI's human exposure modelling system (AirGIS) can improve the Danish data used for exposure factors in the ExternE Transport methodology. Initially, a brief description of the ExternE Tranport methodology is given and it is summarised...

  1. Checklists for external validity

    DEFF Research Database (Denmark)

    Dyrvig, Anne-Kirstine; Kidholm, Kristian; Gerke, Oke

    2014-01-01

    to an implementation setting. In this paper, currently available checklists on external validity are identified, assessed and used as a basis for proposing a new improved instrument. METHOD: A systematic literature review was carried out in Pubmed, Embase and Cinahl on English-language papers without time restrictions....... The retrieved checklist items were assessed for (i) the methodology used in primary literature, justifying inclusion of each item; and (ii) the number of times each item appeared in checklists. RESULTS: Fifteen papers were identified, presenting a total of 21 checklists for external validity, yielding a total...... of 38 checklist items. Empirical support was considered the most valid methodology for item inclusion. Assessment of methodological justification showed that none of the items were supported empirically. Other kinds of literature justified the inclusion of 22 of the items, and 17 items were included...

  2. Other people's accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1987-06-15

    The first report from the Washington Accelerator Conference concentrated on news from the particle physics centres. But the bulk of the Conference covered the use of accelerators in other fields, underlining this valuable spinoff from particle physics.

  3. Improved plasma accelerator

    Science.gov (United States)

    Cheng, D. Y.

    1971-01-01

    Converging, coaxial accelerator electrode configuration operates in vacuum as plasma gun. Plasma forms by periodic injections of high pressure gas that is ionized by electrical discharges. Deflagration mode of discharge provides acceleration, and converging contours of plasma gun provide focusing.

  4. The electron accelerator Ridgetron

    International Nuclear Information System (INIS)

    Hayashizaki, N.; Hattori, T.; Odera, M.; Fujisawa, T.

    1999-01-01

    Many electron accelerators of DC or RF type have been widely used for electron beam irradiation (curing, crosslinking of polymers, sterilization of medical disposables, preservation of food, etc.). Regardless of the acceleration energy, the accelerators to be installed in industrial facilities, have to satisfy the requires of compact size, low power consumption and stable operation. The DC accelerator is realized very compact in the energy under 300 keV, however, it is large to prevent the discharge of an acceleration column in the energy over 300 keV. The RF electron accelerator Ridgetron has been developed to accelerate the continuous beam of the 0.5-10 MeV range in compact space. It is the first example as an electron accelerator incorporated a ridged RF cavity. A prototype system of final energy of 2.5 MeV has been studied to confirm the feasibility at present

  5. High brightness electron accelerator

    International Nuclear Information System (INIS)

    Sheffield, R.L.; Carlsten, B.E.; Young, L.M.

    1994-01-01

    A compact high brightness linear accelerator is provided for use, e.g., in a free electron laser. The accelerator has a first plurality of accelerating cavities having end walls with four coupling slots for accelerating electrons to high velocities in the absence of quadrupole fields. A second plurality of cavities receives the high velocity electrons for further acceleration, where each of the second cavities has end walls with two coupling slots for acceleration in the absence of dipole fields. The accelerator also includes a first cavity with an extended length to provide for phase matching the electron beam along the accelerating cavities. A solenoid is provided about the photocathode that emits the electrons, where the solenoid is configured to provide a substantially uniform magnetic field over the photocathode surface to minimize emittance of the electrons as the electrons enter the first cavity. 5 figs

  6. Unified accelerator libraries

    International Nuclear Information System (INIS)

    Malitsky, Nikolay; Talman, Richard

    1997-01-01

    A 'Universal Accelerator Libraries' (UAL) environment is described. Its purpose is to facilitate program modularity and inter-program and inter-process communication among heterogeneous programs. The goal ultimately is to facilitate model-based control of accelerators

  7. YEREVAN: Acceleration workshop

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Sponsored by the Yerevan Physics Institute in Armenia, a Workshop on New Methods of Charged Particle Acceleration in October near the Nor Amberd Cosmic Ray Station attracted participants from most major accelerator centres in the USSR and further afield

  8. San Francisco Accelerator Conference

    International Nuclear Information System (INIS)

    Southworth, Brian

    1991-01-01

    'Where are today's challenges in accelerator physics?' was the theme of the open session at the San Francisco meeting, the largest ever gathering of accelerator physicists and engineers

  9. Large tandem accelerators

    International Nuclear Information System (INIS)

    Jones, C.M.

    1976-01-01

    The increasing importance of energetic heavy ion beams in the study of atomic physics, nuclear physics, and materials science has partially or wholly motivated the construction of a new generation of tandem accelerators designed to operate at maximum terminal potentials in the range 14 to 30 MV. In addition, a number of older tandem accelerators are now being significantly upgraded to improve their heavy ion performance. Both of these developments have reemphasized the importance of negative heavy ion sources. The new large tandem accelerators are described, and the requirements placed on negative heavy ion source technology by these and other tandem accelerators used for the acceleration of heavy ions are discussed. First, a brief description is given of the large tandem accelerators which have been completed recently, are under construction, or are funded for construction, second, the motivation for construction of these accelerators is discussed, and last, criteria for negative ion sources for use with these accelerators are presented

  10. Accelerator-timing system

    International Nuclear Information System (INIS)

    Timmer, E.; Heine, E.

    1985-01-01

    Along the NIKHEF accelerator in Amsterdam (Netherlands), at several places a signal is needed for the sychronisation of all devices with the acceleration process. In this report, basic principles and arrangements of this timing system are described

  11. Linear accelerator: A concept

    Science.gov (United States)

    Mutzberg, J.

    1972-01-01

    Design is proposed for inexpensive accelerometer which would work by applying pressure to fluid during acceleration. Pressure is used to move shuttle, and shuttle movement is sensed and calibrated to give acceleration readings.

  12. Centrifugal acceleration in the magnetotail lobes

    Directory of Open Access Journals (Sweden)

    H. Nilsson

    2010-02-01

    Full Text Available Combined Cluster EFW and EDI measurements have shown that cold ion outflow in the magnetospheric lobes dominates the hydrogen ion outflow from the Earth's atmosphere. The ions have too low kinetic energy to be measurable with particle instruments, at least for the typical spacecraft potential of a sunlit spacecraft in the tenuous lobe plasmas outside a few RE. The measurement technique yields both density and bulk velocity, which can be combined with magnetic field measurements to estimate the centrifugal acceleration experienced by these particles. We present a quantitative estimate of the centrifugal acceleration, and the velocity change with distance which we would expect due to centrifugal acceleration. It is found that the centrifugal acceleration is on average outward with an average value of about of 5 m s−2. This is small, but acting during long transport times and over long distances the cumulative effect is significant, while still consistent with the relatively low velocities estimated using the combination of EFW and EDI data. The centrifugal acceleration should accelerate any oxygen ions in the lobes to energies observable by particle spectrometers. The data set also put constraints on the effectiveness of any other acceleration mechanisms acting in the lobes, where the total velocity increase between 5 and 19 RE geocentric distance is less than 5 km s−1.

  13. Heavy ion accelerators

    International Nuclear Information System (INIS)

    Schmelzer, C.

    1974-01-01

    This review of the present state of work on heavy-ion accelerators pays particular attention to the requirements for nuclear research. It is divided into the following sections: single-particle versus collective acceleration, heavy-ion accelerators, beam quality, and a status report on the UNILAC facility. Among the topics considered are the recycling cyclotron, linacs with superconducting resonators, and acceleration to the GeV/nucleon range. (8 figures, 2 tables) (U.S.)

  14. Accelerators at school

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Latest subject covered by the CERN Accelerator School was 'Applied Geodesy of Particle Accelerators', which attracted an impressive number of outside participants to CERN for a week in April. Since the forerunners of today's particle accelerators were demonstrated over 50 years ago, the positioning of accelerator components has progressed from the laboratory bench-top to tunnels tens of kilometres long. Despite this phenomenal growth in size, sub-millimetre accuracy is still required

  15. Accelerators at school

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1986-06-15

    Latest subject covered by the CERN Accelerator School was 'Applied Geodesy of Particle Accelerators', which attracted an impressive number of outside participants to CERN for a week in April. Since the forerunners of today's particle accelerators were demonstrated over 50 years ago, the positioning of accelerator components has progressed from the laboratory bench-top to tunnels tens of kilometres long. Despite this phenomenal growth in size, sub-millimetre accuracy is still required.

  16. Accelerators for Medicine

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    This lecture will review the different applications of particle accelerators to the medical field, from cancer treatment with beams of accelerator-produced particles (photons, electrons, protons, ions and neutrons) to the generation of radioactive isotopes used in medical diagnostics, in cancer therapy and in the new domain of theragnostics. For each application will be outlined the state of the art, the potential, and the accelerator challenges to be faced to meet the increasing demand for therapeutic procedures based on accelerators.

  17. Large electrostatic accelerators

    International Nuclear Information System (INIS)

    Jones, C.M.

    1984-01-01

    The paper is divided into four parts: a discussion of the motivation for the construction of large electrostatic accelerators, a description and discussion of several large electrostatic accelerators which have been recently completed or are under construction, a description of several recent innovations which may be expected to improve the performance of large electrostatic accelerators in the future, and a description of an innovative new large electrostatic accelerator whose construction is scheduled to begin next year

  18. Particle beam accelerator

    International Nuclear Information System (INIS)

    Turner, N.L.

    1982-01-01

    A particle beam accelerator is described which has several electrodes that are selectively short circuited together synchronously with changes in the magnitude of a DC voltage applied to the accelerator. By this method a substantially constant voltage gradient is maintained along the length of the unshortened electrodes despite variations in the energy applied to the beam by the accelerator. The invention has particular application to accelerating ion beams that are implanted into semiconductor wafers. (U.K.)

  19. Superconducting accelerator technology

    International Nuclear Information System (INIS)

    Grunder, H.A.; Hartline, B.K.

    1986-01-01

    Modern and future accelerators for high energy and nuclear physics rely increasingly on superconducting components to achieve the required magnetic fields and accelerating fields. This paper presents a practical overview of the phenomenon of superconductivity, and describes the design issues and solutions associated with superconducting magnets and superconducting rf acceleration structures. Further development and application of superconducting components promises increased accelerator performance at reduced electric power cost

  20. Applications of particle accelerators

    International Nuclear Information System (INIS)

    Barbalat, O.

    1994-01-01

    Particle accelerators are now widely used in a variety of applications for scientific research, applied physics, medicine, industrial processing, while possible utilisation in power engineering is envisaged. Earlier presentations of this subject, given at previous CERN Accelerator School sessions have been updated with papers contributed to the first European Conference on Accelerators in Applied Research and Technology (ECAART) held in September 1989 in Frankfurt and to the Second European Particle Accelerator Conference in Nice in June 1990. (orig.)

  1. Tetra-2,3-pyrazinoporphyrazines with externally appended pyridine rings. 15. Effects of the pyridyl substituents and fused exocyclic rings on the UV-visible spectroscopic properties of Mg(II)-porphyrazines: a combined experimental and DFT/TDDFT study.

    Science.gov (United States)

    Donzello, Maria Pia; De Mori, Giorgia; Viola, Elisa; Ercolani, Claudio; Ricciardi, Giampaolo; Rosa, Angela

    2014-08-04

    Two new Mg(II) porphyrazine macrocycles, the octakis(2-pyridyl)porphyrazinato-magnesium(II), [Py8PzMg(H2O)], and the tetrakis-[6,7-di(2-pyridyl)quinoxalino]porphyrazinato-magnesium(II), [Py8QxPzMg(H2O)], were prepared by Mg-template macrocyclization processes, and their general physicochemical properties were examined. The previously reported porphyrazine analog, the tetrakis-2,3-[5,6-di(2-pyridyl)-pyrazino]porphyrazinato-magnesium(II), [Py8PyzPzMg(H2O)], has been also considered in the present work. The UV-visible solution spectra in nonaqueous solvents of this triad of externally octapyridinated Mg(II) complexes exhibit the usual profile observed for phthalocyanine and porphyrazine macrocycles, with intense absorptions in the Soret (300-450 nm) and Q band (600-800 nm) regions. It is observed that the Q band maximum sensibly shifts toward the red with peak values at 635 → 658 → 759 nm along the series [Py8PzMg(H2O)], [Py8PyzPzMg(H2O)], and [Py8QxPzMg(H2O)], as the extension of the macrocycle π-system increases. TDDFT calculations of the electronic absorption spectra were performed for the related water-free model compounds [Py8PzMg], [Py8PyzPzMg], and [Py8QxPzMg] to provide an interpretation of the UV-visible spectral changes occurring upon introduction of the pyrazine and quinoxaline rings at the periphery of the Pz macrocycle. To discriminate the electronic effects of the fused exocyclic rings from those of the appended 2-pyridyl rings, the UV-visible spectra of [PzMg] and [PyzPzMg] were also theoretically investigated. The theoretical results prove to agree very well with the experimental data, providing an accurate description of the UV-visible spectra. The observed spectral changes are interpreted on the basis of the electronic structure changes occurring along the series.

  2. The external respiration and gas exchange in space missions

    Science.gov (United States)

    Baranov, V. M.; Tikhonov, M. A.; Kotov, A. N.

    Literature data and results of our own studies into an effect of micro- and macro-gravity on an external respiration function of man are presented. It is found that in cosmonauts following the 7-366 day space missions there is an enhanced tendency associated with an increased flight duration toward a decrease in the lung volume and breathing mechanics parameters: forced vital capacity of the lungs (FVC) by 5-25 percent, peak inspiratory and expiratory (air) flows (PIF, PEF) by 5-40 percent. A decrease in FVC appears to be explained by a new balance of elastic forces of the lungs, chest and abdomen occuring in microgravity as well as by an increased blood filling and pulmonary hydration. A decline of PIF and PEF is probalbly resulted from antigravitational deconditioning of the respiratory muscles with which a postflight decreased physical performance can in part be associated. The ventilation/perfusion ratios during orthostasis and +G Z and +G X accelerations are estimated. The biophysical nature of developing the absorption atelectases on a combined exposure to accelerations and 100% oxygen breathing is confirmed. A hypothesis that hypervolemia and pulmonary congestion can increase the tendency toward the development of atelectases in space in particular during pure oxygen breathing is suggested. Respiratory physiology problem area which is of interest for space medicine is defined. It is well known that due to present-day technologic progress and accomplishments in applied physiology including applied respiration physiology there currently exist sophisticated technical facilities in operation maintaining the life and professional working capacity of a man in various natural environments: on Earth, under water and in space. By the way, the biomedical involvement in developing and constructing such facilities has enabled an accumulation of a great body of information from experimental studies and full-scale trails to examine the effects of the changed environments

  3. Combined homicide

    Directory of Open Access Journals (Sweden)

    Slović Živana

    2017-01-01

    Full Text Available Introduction: Combined homicide is a combination of two or more different modes of killing. These homicides occur when multiple perpetrators have different mode of killing, to hide the true manner of death, or when an initially unsuccessful attack with one weapon is abandoned and changed by another mode which is more successful, or due to availability of weapons at the scene of homicide, or unexpected appearance of possible eyewitness, or else. Case report: This case report is about 65-year old woman who was found in her residence on the floor next to the bed lying on her back with two kitchen knives in her neck. Autopsy revealed an abrasion on the frontal part of the neck and a bruise of the soft tissues of the neck with a double fracture of both greater horns of the hyoid bone and a fracture of both superior horns of the thyroid cartilage. The cause of death was exsanguination into right half of the thoracic cavity from the left subclavian artery which was cut, on the spot of stab wound in the neck. Conclusion: Hemorrhage in the soft tissue near broken hyoid bone and thyroid cartilage indicate that the victim was first strangulated and then stabbed with kitchen knives. Combined homicides are caused by one or more killers in order to accelerate the killing, or to be sure to provide the fatal outcome. This case is also interesting because the killer left weapon in the victim's neck.

  4. The CERN Accelerator School

    CERN Multimedia

    2016-01-01

    Introduction to accelerator physics The CERN Accelerator School: Introduction to Accelerator Physics, which should have taken place in Istanbul, Turkey, later this year has now been relocated to Budapest, Hungary.  Further details regarding the new hotel and dates will be made available as soon as possible on a new Indico site at the end of May.

  5. Angular Acceleration without Torque?

    Science.gov (United States)

    Kaufman, Richard D.

    2012-01-01

    Hardly. Just as Robert Johns qualitatively describes angular acceleration by an internal force in his article "Acceleration Without Force?" here we will extend the discussion to consider angular acceleration by an internal torque. As we will see, this internal torque is due to an internal force acting at a distance from an instantaneous center.

  6. Accelerators and Dinosaurs

    CERN Multimedia

    Turner, Michael Stanley

    2003-01-01

    Using naturally occuring particles on which to research might have made accelerators become extinct. But in fact, results from astrophysics have made accelerator physics even more important. Not only are accelerators used in hospitals but they are also being used to understand nature's inner workings by searching for Higgs bosons, CP violation, neutrino mass and dark matter (2 pages)

  7. Far field acceleration

    International Nuclear Information System (INIS)

    Fernow, R.C.

    1995-07-01

    Far fields are propagating electromagnetic waves far from their source, boundary surfaces, and free charges. The general principles governing the acceleration of charged particles by far fields are reviewed. A survey of proposed field configurations is given. The two most important schemes, Inverse Cerenkov acceleration and Inverse free electron laser acceleration, are discussed in detail

  8. Operation of the Brookhaven national laboratory accelerator test facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; Van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program. (Author) 5 refs., 4 figs., tab

  9. Operation of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program

  10. Reducing longitudinal emittance growth in RFQ accelerators

    International Nuclear Information System (INIS)

    Koscielniak, S.

    1994-08-01

    Bunching and capture of a monochromatic beam into an rf bucket inevitably lead to substantial emittance growth through the mechanisms of filamentation and non-adiabatic variation of parameters. We describe a three step strategy for minimizing this growth, based on a clear understanding of the non-linear beam dynamics, and apply to acceleration of heavy ions with Z/A = 1/60 (and initial kinetic energy 60 keV/u) in a radio frequency quadrupole (RFQ) operating at 25 MHz. We also describe a scheme, to further reduce the emittance, based upon the use of an external RFQ-type prebuncher before the main accelerator. The external unit permits the bunching voltage to be reduced, to inject into a moving bucket, and to reduce the structure length. (author). 7 refs., 6 figs

  11. External-beam radiation therapy combined with limb-sparing surgery in elderly patients (>70 years) with primary soft tissue sarcomas of the extremities : A retrospective analysis.

    Science.gov (United States)

    Andrä, Claudia; Klein, Alexander; Dürr, Hans Roland; Rauch, Josefine; Lindner, Lars Hartwin; Knoesel, Thomas; Angele, Martin; Baur-Melnyk, Andrea; Belka, Claus; Roeder, Falk

    2017-08-01

    To report our experience with EBRT combined with limb-sparing surgery in elderly patients (>70 years) with primary extremity soft tissue sarcomas (STS). Retrospectively analyzed were 35 patients (m:f 18:17, median 78 years) who all presented in primary situation without nodal/distant metastases (Charlson score 0/1 in 18 patients; ≥2 in 17 patients). Median tumor size was 10 cm, mainly located in lower limb (83%). Stage at presentation (UICC7th) was Ib:3%, 2a:20%, 2b:20%, and 3:57%. Most lesions were high grade (97%), predominantly leiomyosarcoma (26%) and undifferentiated pleomorphic/malignant fibrous histiocytoma (23%). Limb-sparing surgery was preceded (median 50 Gy) or followed (median 66 Gy) by EBRT. Median follow-up was 37 months (range 1-128 months). Margins were free in 26 patients (74%) and microscopically positive in 9 (26%). Actuarial 3‑ and 5‑year local control rates were 88 and 81% (4 local recurrences). Corresponding rates for distant control, disease-specific survival, and overall survival were 57/52%, 76/60%, and 72/41%. The 30-day mortality was 0%. Severe postoperative complications were scored in 8 patients (23%). Severe acute radiation-related toxicity was observed in 2 patients (6%). Patients with Charlson score ≥2 had a significantly increased risk for severe postoperative complications and acute radiation-related side effects. Severe late toxicities were found in 7 patients (20%), including fractures in 3 (8.6%). Final limb preservation rate was 97%. Combination of EBRT and limb-sparing surgery is feasible in elderly patients with acceptable toxicities and encouraging but slightly inferior outcome compared to younger patients. Comorbidity correlated with postoperative complications and acute toxicities. Late fracture risk seems slightly increased.

  12. An overview of collective effects in circular and linear accelerators

    International Nuclear Information System (INIS)

    Ruth, R.D.

    1989-04-01

    The purpose of both linear and circular accelerator is, of course, to accelerate beams of charged particles. In order to do this it is necessary not only to accelerate particles but also to confine them transversely so that they remain in the vacuum environment. Originally, as accelerators were developed, the intensity of the beams was rather low and so the external fields could be applied without regard to the effects of the space-charge forces of the beams. However, as the demand for high intensity increased, collective effects that are due to the space-charge forces became increasingly important. In order to control a beam of particles we apply external fields. These focus the beam transversely and accelerate it and focus it longitudinally. In addition to these externally applied fields a particle within the beam feels a field due to the charge and current of all the other particles in the beam. By collective effects, we mean all those modifications to the beam behavior which are due to these beam-induced forces. The first two major topics discussed are linear and circular accelerators. In the linear accelerator case, we will consider as examples only electron linacs that have relatively high energy and so particles will have ν ≅ c. For circular accelerators we'll consider both protons and electrons or their anti-particles. The next two topics are single bunches and multi-bunches. In both linear accelerators and circular accelerators the particles have a bunched character because they are accelerated by an RF system, and the RF has a natural wavelength. The next two topics arise from the natural separation of longitudinal and transverse effects. 40 refs., 30 figs., 1 tab

  13. Virtual Accelerator for Accelerator Optics Improvement

    CERN Document Server

    Yan Yi Ton; Decker, Franz Josef; Ecklund, Stanley; Irwin, John; Seeman, John; Sullivan, Michael K; Turner, J L; Wienands, Ulrich

    2005-01-01

    Through determination of all quadrupole strengths and sextupole feed-downs by fitting quantities derivable from precision orbit measurement, one can establish a virtual accelerator that matches the real accelerator optics. These quantities (the phase advances, the Green's functions, and the coupling eigen-plane ellipses tilt angles and axis ratios) are obtained by analyzing turn-by-turn Beam Position Monitor (BPM) data with a model-independent analysis (MIA). Instead of trying to identify magnet errors, a limited number of quadrupoles are chosen for optimized strength adjustment to improve the virtual accelerator optics and then applied to the real accelerator accordingly. These processes have been successfully applied to PEP-II rings for beta beating fixes, phase and working tune adjustments, and linear coupling reduction to improve PEP-II luminosity.

  14. The cyclotron laboratory and the RFQ accelerator in Bern

    International Nuclear Information System (INIS)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M.; Scampoli, P.; Bremen, K. von

    2013-01-01

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study

  15. The cyclotron laboratory and the RFQ accelerator in Bern

    Energy Technology Data Exchange (ETDEWEB)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland); Scampoli, P. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland and Department of Physical Sciences, University Federico II, Via Cintia, I-60126 Napoli (Italy); Bremen, K. von [SWAN Isotopen AG, Inselspital, CH-3010 Bern (Switzerland)

    2013-07-18

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  16. The Accelerator Reliability Forum

    CERN Document Server

    Lüdeke, Andreas; Giachino, R

    2014-01-01

    A high reliability is a very important goal for most particle accelerators. The biennial Accelerator Reliability Workshop covers topics related to the design and operation of particle accelerators with a high reliability. In order to optimize the over-all reliability of an accelerator one needs to gather information on the reliability of many different subsystems. While a biennial workshop can serve as a platform for the exchange of such information, the authors aimed to provide a further channel to allow for a more timely communication: the Particle Accelerator Reliability Forum [1]. This contribution will describe the forum and advertise it’s usage in the community.

  17. Notes on Laser Acceleration

    International Nuclear Information System (INIS)

    Tajima, T.

    2008-01-01

    This note intends to motivate our effort toward the advent of new methods of particle acceleration, utilizing the fast rising laser technology. By illustrating the underlying principles in an intuitive manner and thus less jargon-clad fashion, we seek a direction in which we shall be able to properly control and harness the promise of laser acceleration. First we review the idea behind the laser wakefield. We then go on to examine ion acceleration by laser. We examine the sheath acceleration in particular and look for the future direction that allows orderly acceleration of ions in high energies

  18. Electron Surfing Acceleration in Magnetic Reconnection

    OpenAIRE

    Hoshino, Masahiro

    2005-01-01

    We discuss that energetic electrons are generated near the X-type magnetic reconnection region due to a surfing acceleration mechanism. In a thin plasma sheet, the polarization electric fields pointing towards the neutral sheet are induced around the boundary between the lobe and plasma sheet in association with the Hall electric current. By using a particle-in-cell simulation, we demonstrate that the polarization electric fields are strongly enhanced in an externally driven reconnection syst...

  19. Renewable energy: Externality costs as market barriers

    International Nuclear Information System (INIS)

    Owen, Anthony D.

    2006-01-01

    This paper addresses the impact of environmentally based market failure constraints on the adoption of renewable energy technologies through the quantification in financial terms of the externalities of electric power generation, for a range of alternative commercial and almost-commercial technologies. It is shown that estimates of damage costs resulting from combustion of fossil fuels, if internalised into the price of the resulting output of electricity, could lead to a number of renewable technologies being financially competitive with generation from coal plants. However, combined cycle natural gas technology would have a significant financial advantage over both coal and renewables under current technology options and market conditions. On the basis of cost projections made under the assumption of mature technologies and the existence of economies of scale, renewable technologies would possess a significant social cost advantage if the externalities of power production were to be 'internalised'. Incorporating environmental externalities explicitly into the electricity tariff today would serve to hasten this transition process. (author)

  20. Industrial Application of Accelerators

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    At CERN, we are very familiar with large, high energy particle accelerators. However, in the world outside CERN, there are more than 35000 accelerators which are used for applications ranging from treating cancer, through making better electronics to removing harmful micro-organisms from food and water. These are responsible for around $0.5T of commerce each year. Almost all are less than 20 MeV and most use accelerator types that are somewhat different from what is at CERN. These lectures will describe some of the most common applications, some of the newer applications in development and the accelerator technology used for them. It will also show examples of where technology developed for particle physics is now being studied for these applications. Rob Edgecock is a Professor of Accelerator Science, with a particular interest in the medical applications of accelerators. He works jointly for the STFC Rutherford Appleton Laboratory and the International Institute for Accelerator Applications at the Univer...

  1. Industrial Application of Accelerators

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    At CERN, we are very familiar with large, high energy particle accelerators. However, in the world outside CERN, there are more than 35000 accelerators which are used for applications ranging from treating cancer, through making better electronics to removing harmful micro-organisms from food and water. These are responsible for around $0.5T of commerce each year. Almost all are less than 20 MeV and most use accelerator types that are somewhat different from what is at CERN. These lectures will describe some of the most common applications, some of the newer applications in development and the accelerator technology used for them. It will also show examples of where technology developed for particle physics is now being studied for these applications. Rob Edgecock is a Professor of Accelerator Science, with a particular interest in the medical applications of accelerators. He works jointly for the STFC Rutherford Appleton Laboratory and the International Institute for Accelerator Applications at the Uni...

  2. Accelerations in Flight

    Science.gov (United States)

    Doolittle, J H

    1925-01-01

    This work on accelerometry was done at McCook Field for the purpose of continuing the work done by other investigators and obtaining the accelerations which occur when a high-speed pursuit airplane is subjected to the more common maneuvers. The accelerations obtained in suddenly pulling out of a dive with well-balanced elevators are shown to be within 3 or 4 per cent of the theoretically possible accelerations. The maximum acceleration which a pilot can withstand depends upon the length of time the acceleration is continued. It is shown that he experiences no difficulty under the instantaneous accelerations as high as 7.8 G., but when under accelerations in excess of 4.5 G., continued for several seconds, he quickly loses his faculties.

  3. External proton and Li beams

    International Nuclear Information System (INIS)

    Schuff, Juan A.; Burlon, Alejandro A.; Debray, Mario E.; Kesque, Jose M.; Kreiner, Andres J.; Stoliar, Pablo A.; Naab, Fabian; Ozafran, Mabel J.; Vazquez, Monica E.; Perez de la Hoz, A.; Somacal, Hector; Valda, Alejandro; Canevas, S.; Ruffolo, M.; Tasat, D.R.; Muhlmann, M. C.

    2000-01-01

    In the frame of a feasibility study to introduce proton therapy in Argentina in a collaborative agreement between the Physics and Radiobiology Departments of the National Atomic Energy Commission or Argentina and the Centre de Protontherapie de Orsay, France, external proton and Li beams were produced at the TANDAR accelerator in Buenos Aires. The specific aim of this work was to start radiobiology studies on cell cultures and small laboratory animals. In particular we seek to determine here the relative biological effectiveness, RBE, for proton and Li beams as a function of energy for different tumor and normal cell lines. The 24 MeV proton beam was diffused using a 25 μm gold foil and extracted through a Kapton window to obtain a homogeneous field (constant to 95%) of about 7 cm in diameter. Measurements were carried out with quasi-monoenergetic beams (of 20.2 ± 0.07 MeV, 2.9 ± 0.10 MeV y 1.5 ± 0.1 MeV for protons and 21.4 ± 0.4 MeV for Lithium). Proton fluence and Bragg peaks were measured. The dose delivered in each case was monitored on-line with a calibrated transmission ionization chamber. Three cell lines PDV, PDVC 57 and V 79 (as a reference) were irradiated with γ-rays, proton and lithium beams with linear energy transfer (LET) from 2 to 100 keV/μm. RBE values in the range of 1.2-5.9 were obtained. In addition preliminary studies on chromosomal aberrations and viability of alveolar macrophages were carried out. (author)

  4. Personal computers in accelerator control

    International Nuclear Information System (INIS)

    Anderssen, P.S.

    1988-01-01

    The advent of the personal computer has created a popular movement which has also made a strong impact on science and engineering. Flexible software environments combined with good computational performance and large storage capacities are becoming available at steadily decreasing costs. Of equal importance, however, is the quality of the user interface offered on many of these products. Graphics and screen interaction is available in ways that were only possible on specialized systems before. Accelerator engineers were quick to pick up the new technology. The first applications were probably for controllers and data gatherers for beam measurement equipment. Others followed, and today it is conceivable to make personal computer a standard component of an accelerator control system. This paper reviews the experience gained at CERN so far and describes the approach taken in the design of the common control center for the SPS and the future LEP accelerators. The design goal has been to be able to integrate personal computers into the accelerator control system and to build the operator's workplace around it. (orig.)

  5. Advanced Accelerator Applications in Medicine

    International Nuclear Information System (INIS)

    Rimjiaem, Sakhorn

    2015-01-01

    besides the original purpose on development of particle acceleratora as research tools in nuclear and high-energy physics, there are large variety of accelerators used in various fileds from fundamental research to industrial usesand applications chemistry, biology and medicine. Pratical accelators used in various field of medical applications since serveral decades. Even through, a large fraction of applications is emphasized on cancer therappy, the number of accelerators used in midicine for other diagnostics and treatments has increased steady over the years. Several types of accelerated particles are used including electron, proton, neutron and ions. Presently, relativistic electron beams and radiation from linear accelerators (linas) are widely used. A combination of positron emission tomography (PRT) and radiotherapy is an example of excellent invention early detection and treat of cancer tumors. The most developments for proton and heavy ion therapy as well as a modern boron neutron capture therapy (BNCT) are also great incoming effective systems. This talk will focus on developments of the accelrator systems as well as overview on biophysical properties and medical aspects of the diacnostics and treatments.

  6. Environmental external effects from wind power based on the EU ExternE methodology

    DEFF Research Database (Denmark)

    Ibsen, Liselotte Schleisner; Nielsen, Per Sieverts

    1998-01-01

    of the Danish part of the project is to implement the framework for externality evaluation, for three different power plants located in Denmark. The paper will focus on the assessment of the impacts of the whole fuel cycles for wind, natural gas and biogas. Priority areas for environmental impact assessment......The European Commission has launched a major study project, ExternE, to develop a methodology to quantify externalities. A “National Implementation Phase”, was started under the Joule II programme with the purpose of implementing the ExternE methodology in all member states. The main objective...

  7. External corners as heat bridges

    Energy Technology Data Exchange (ETDEWEB)

    Berber, J.

    1984-08-01

    The maximum additional heat loss in vertical external corners depending on wall thickness is determined. In order to amire at a low k-value, a much smaller wall thickness is required in externally insulated walls than in monolithic constructions; the greater loss of heat bridge with external insulation stands in contrast to a higher loss in thick, monolithic walls. In relation to total losses, the additional losses through external corners are practically negligible.

  8. [External pancreatic fistulas management].

    Science.gov (United States)

    Stepan, E V; Ermolov, A S; Rogal', M L; Teterin, Yu S

    The main principles of treatment of external postoperative pancreatic fistulas are viewed in the article. Pancreatic trauma was the reason of pancreatic fistula in 38.7% of the cases, operations because of acute pancreatitis - in 25.8%, and pancreatic pseudocyst drainage - in 35.5%. 93 patients recovered after the treatment. Complex conservative treatment of EPF allowed to close fistulas in 74.2% of the patients with normal patency of the main pancreatic duct (MPD). The usage of octreotide 600-900 mcg daily for at least 5 days to decrease pancreatic secretion was an important part of the conservative treatment. Endoscopic papillotomy was performed in patients with major duodenal papilla obstruction and interruption of transporting of pancreatic secretion to duodenum. Stent of the main pancreatic duct was indicated in patients with extended pancreatic duct stenosis to normalize transport of pancreatic secretion to duodenum. Surgical formation of anastomosis between distal part of the main pancreatic duct and gastro-intestinal tract was carried out when it was impossible to fulfill endoscopic stenting of pancreatic duct either because of its interruption and diastasis between its ends, or in the cases of unsuccessful conservative treatment of external pancreatic fistula caused by drainage of pseudocyst.

  9. Advanced beam dynamics and diagnostics concepts for laser-plasma accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Dornmair, Irene

    2017-05-15

    Laser-Plasma Accelerators (LPAs) combine a multitude of unique features, which makes them very attractive as drivers for next generation brilliant light sources including compact X-ray free-electron lasers. They provide high accelerating gradients, thereby drastically shrinking the accelerator size, while at the same time the produced electron bunches are intrinsically as short as a few femtoseconds and carry high peak currents. LPA are subject of very active research, yet, the field currently faces the challenge of improving the beam quality, and achieving stable and well-controlled injection and acceleration. This thesis tackles this issue from three different sides. A novellongitudinal phase space diagnostics is proposed that employs the strong fields present in plasma wakefields to streak ultrashort electron bunches. This allows for a temporal resolution down to the attosecond range, enabling direct determination to the current profile and the slice energy spread, both crucial quantities for the performance of free-electron lasers. Furthermore, adiabatic matching sections at the plasma-vacuum boundary are investigated. These can drastically reduce the beam divergence and thereby relax the constraints on the subsequent beam optics. For externally injected beams, the matching sections could even provide the key technology that permits emittance conservation by increasing the matched beam size to a level achievable with currently available magnetic optics. Finally, a new method is studied that allows to modify the wakefield shape. To this end, the plasma density is periodically modulated. One possible application can be to remove the linearly correlated energy spread, or chirp, from the accelerated bunch, which is suspected of being responsible for the main part of the often large energy spread of plasma accelerated beams.

  10. Advanced beam dynamics and diagnostics concepts for laser-plasma accelerators

    International Nuclear Information System (INIS)

    Dornmair, Irene

    2017-05-01

    Laser-Plasma Accelerators (LPAs) combine a multitude of unique features, which makes them very attractive as drivers for next generation brilliant light sources including compact X-ray free-electron lasers. They provide high accelerating gradients, thereby drastically shrinking the accelerator size, while at the same time the produced electron bunches are intrinsically as short as a few femtoseconds and carry high peak currents. LPA are subject of very active research, yet, the field currently faces the challenge of improving the beam quality, and achieving stable and well-controlled injection and acceleration. This thesis tackles this issue from three different sides. A novellongitudinal phase space diagnostics is proposed that employs the strong fields present in plasma wakefields to streak ultrashort electron bunches. This allows for a temporal resolution down to the attosecond range, enabling direct determination to the current profile and the slice energy spread, both crucial quantities for the performance of free-electron lasers. Furthermore, adiabatic matching sections at the plasma-vacuum boundary are investigated. These can drastically reduce the beam divergence and thereby relax the constraints on the subsequent beam optics. For externally injected beams, the matching sections could even provide the key technology that permits emittance conservation by increasing the matched beam size to a level achievable with currently available magnetic optics. Finally, a new method is studied that allows to modify the wakefield shape. To this end, the plasma density is periodically modulated. One possible application can be to remove the linearly correlated energy spread, or chirp, from the accelerated bunch, which is suspected of being responsible for the main part of the often large energy spread of plasma accelerated beams.

  11. Nonlinear acceleration of transport criticality problems

    International Nuclear Information System (INIS)

    Park, H.; Knoll, D.A.; Newman, C.K.

    2011-01-01

    We present a nonlinear acceleration algorithm for the transport criticality problem. The algorithm combines the well-known nonlinear diffusion acceleration (NDA) with a recently developed, Newton-based, nonlinear criticality acceleration (NCA) algorithm. The algorithm first employs the NDA to reduce the system to scalar flux, then the NCA is applied to the resulting drift-diffusion system. We apply a nonlinear elimination technique to eliminate the eigenvalue from the Jacobian matrix. Numerical results show that the algorithm reduces the CPU time a factor of 400 in a very diffusive system, and a factor of 5 in a non-diffusive system. (author)

  12. Externally guided target for inertial fusion

    International Nuclear Information System (INIS)

    Martinez-Val, J.M.; Piera, M.

    1996-01-01

    A totally new concept is proposed to reach fusion conditions by externally guided inertial confinement. The acceleration and compression of the fuel is guided by a cannon-like external duct with a conical section ending in a small-size cavity around the central point of the tube. The fuel pellets coming from each cannon mouth collide in the central cavity where the implosion and final compression of the fuel take place. Both the tube material density and its areal density must be much higher than the initial density and areal density of the fuel. The external tube will explode into pieces as a consequence of the inner pressures achieved after the fuel central collision. If the collision is suitably driven, a fusion burst can take place before the tube disassembly. because of the features of the central collision needed to trigger ignition, this concept could be considered as tamped impact fusion. Both the fusion products and the debris from the guide tube are caught by a liquid-lithium curtain surrounding the target. Only two driving beams are necessary. The system can be applied to any type of driver and could use a solid pellet at room temperature as the initial target. 54 refs., 24 figs., 1 tab

  13. Particle-accelerator decommissioning

    International Nuclear Information System (INIS)

    Opelka, J.H.; Mundis, R.L.; Marmer, G.J.; Peterson, J.M.; Siskind, B.; Kikta, M.J.

    1979-12-01

    Generic considerations involved in decommissioning particle accelerators are examined. There are presently several hundred accelerators operating in the United States that can produce material containing nonnegligible residual radioactivity. Residual radioactivity after final shutdown is generally short-lived induced activity and is localized in hot spots around the beam line. The decommissioning options addressed are mothballing, entombment, dismantlement with interim storage, and dismantlement with disposal. The recycle of components or entire accelerators following dismantlement is a definite possibility and has occurred in the past. Accelerator components can be recycled either immediately at accelerator shutdown or following a period of storage, depending on the nature of induced activation. Considerations of cost, radioactive waste, and radiological health are presented for four prototypic accelerators. Prototypes considered range from small accelerators having minimal amounts of radioactive mmaterial to a very large accelerator having massive components containing nonnegligible amounts of induced activation. Archival information on past decommissionings is presented, and recommendations concerning regulations and accelerator design that will aid in the decommissioning of an accelerator are given

  14. An introduction to acceleration mechanisms

    International Nuclear Information System (INIS)

    Palmer, R.B.

    1987-05-01

    This paper discusses the acceleration of charged particles by electromagnetic fields, i.e., by fields that are produced by the motion of other charged particles driven by some power source. The mechanisms that are discussed include: Ponderamotive Forces, Acceleration, Plasma Beat Wave Acceleration, Inverse Free Electron Laser Acceleration, Inverse Cerenkov Acceleration, Gravity Acceleration, 2D Linac Acceleration and Conventional Iris Loaded Linac Structure Acceleration

  15. Accelerating the life of transistors

    International Nuclear Information System (INIS)

    Qi Haochun; Lü Changzhi; Zhang Xiaoling; Xie Xuesong

    2013-01-01

    Choosing small and medium power switching transistors of the NPN type in a 3DK set as the study object, the test of accelerating life is conducted in constant temperature and humidity, and then the data are statistically analyzed with software developed by ourselves. According to degradations of such sensitive parameters as the reverse leakage current of transistors, the lifetime order of transistors is about more than 10 4 at 100 °C and 100% relative humidity (RH) conditions. By corrosion fracture of transistor outer leads and other failure modes, with the failure truncated testing, the average lifetime rank of transistors in different distributions is extrapolated about 10 3 . Failure mechanism analyses of degradation of electrical parameters, outer lead fracture and other reasons that affect transistor lifetime are conducted. The findings show that the impact of external stress of outer leads on transistor reliability is more serious than that of parameter degradation. (semiconductor devices)

  16. Optically isolated electronic trigger system for experiments on a subnanosecond time scale with a pulsed Van de Graaff electron accelerator

    International Nuclear Information System (INIS)

    Luthjens, L.H.; Vermeulen, M.J.W.; Hom, M.L.

    1980-01-01

    An optically isolated electronic trigger system for a pulsed Van de Graaff electron accelerator, producing an external pretrigger pulse 75 ns before arrival of the electron pulse at the target, is described. The total time jitter between trigger signal and electron pulse is 50 ps. The measurement of optical and electrical transients on a subnanosecond time scale with a sequential sampling oscilloscope is demonstrated. The contribution of various parts of the equipment to the total jitter is discussed. Those contributions to the jitter due to the electron transit time fluctuations in the accelerator assuming a constant acceleration voltage gradient and to the shot noise in the photomultiplier detector of the trigger system are calculated to be 5 ps and 12 to 21 ps respectively. Comparison with the experimental results leads to the conclusion that a considerable part of the total jitter may be attributed to acceleration voltage gradient fluctuations, to accelerator vibrations and possibly to density fluctuations in the insulation gas. Possible improvements of the trigger system are discussed. The apparatus is used for pulse radiolysis experiments with subnanosecond time resolution down to 100 ps in combination with subnanosecond time duration electron pulses

  17. External injection systems applied in modern cyclotrons designed and manufactured in NIIEFA

    International Nuclear Information System (INIS)

    Bogdanov, P.V.; Vasilchenko, I.N.; Veresov, O.L.; Gavrish, Yu.N.; Grigorenko, S.V.; Zuev, Yu.V.; Kozienko, M.T.; Mudrolyubov, V.G.; Strokach, A.P.; Tsygankov, S.S.

    2012-01-01

    The main parameters and design features of the external injection systems applied in modern cyclotrons designed and manufactured in NIIEFA and intended for production of radionuclides for medicine are presented. The use of these external injection systems instead of a traditional internal source allows the current of the accelerated beam to be significantly increased and the in-leakage of the working gas to the acceleration chamber to be reduced, which results in reduced beam losses in the process of acceleration and lower equipment activation.

  18. Accelerator research studies: Progress report, Task B

    International Nuclear Information System (INIS)

    1985-06-01

    The main objectives in Task B of the research program are summarized as follows: (1) studies of the collective acceleration of positive ions from a localized plasma source by an intense relativistic electron beam (IREB), (2) studies of ways in which external control may be achieved over the electron beam front in order to achieve higher ion energies - the Beam Front Accelerator (BFA) concept, and (3) study of electron and ion beam generation in a new kind of compact pulsed accelerator in which energy is stored inductively and switched using a plasma focus opening switch. During the past year, substantial progress was made in each of these areas. Our exploratory research on the collective acceleration of laser-produced ions has confirmed the acceleration of C, Al, and Fe ions to peak energies in excess of 10 MeV/amu. In addition, studies of the relation between collective ion acceleration and electron beam propagation in vacuum have shed new light on the experimental processes that lead to energy transfer from electrons to ions. Meanwhile, extensive progress has been made in our attempts to use analytical theory and numerical simulation to model ion acceleration in these systems. Our resultant improved understanding of the processes that limit the peak ion energy has had a profound impact on our plans for further research in this area. Studies of the Compact Pulsed Accelerator have included both ion and electron beam extraction from the device. Its potential to reduce the volume of pulse power sources by an order of magnitude has already been demonstrated, and plans are currently underway to scale the experiment up to voltages in the 1 MV range

  19. Accelerator and radiation physics

    CERN Document Server

    Basu, Samita; Nandy, Maitreyee

    2013-01-01

    "Accelerator and radiation physics" encompasses radiation shielding design and strategies for hadron therapy accelerators, neutron facilities and laser based accelerators. A fascinating article describes detailed transport theory and its application to radiation transport. Detailed information on planning and design of a very high energy proton accelerator can be obtained from the article on radiological safety of J-PARC. Besides safety for proton accelerators, the book provides information on radiological safety issues for electron synchrotron and prevention and preparedness for radiological emergencies. Different methods for neutron dosimetry including LET based monitoring, time of flight spectrometry, track detectors are documented alongwith newly measured experimental data on radiation interaction with dyes, polymers, bones and other materials. Design of deuteron accelerator, shielding in beam line hutches in synchrotron and 14 MeV neutron generator, various radiation detection methods, their characteriza...

  20. 2014 Accelerators meeting, Grenoble

    International Nuclear Information System (INIS)

    Lucotte, Arnaud; Lamy, Thierry; De Conto, Jean-Marie; Fontaine, Alain; Revol, Jean-Luc; Nadolski, Laurent S.; Kazamias, Sophie; Vretenar, Maurizio; Ferrando, Philippe; Laune, Bernard; Vedrine, Pierre

    2014-10-01

    The Accelerators meeting is organised every two years by the Accelerators division of the French Society of Physics (SFP). It brings together about 50 participants during a one-day meeting. The morning sessions are devoted to scientific presentations while the afternoon is dedicated to technical visits of facilities. This document brings together the available presentations (slides): 1 - Presentation of the Laboratory of subatomic physics and cosmology - LPSC-Grenoble (Lucotte, Arnaud; Lamy, Thierry); 2 - Presentation of the Accelerators division of the French Society of Physics (Fontaine, Alain; Revol, Jean-Luc); 3 - Presentation of Grenoble's master diplomas in Accelerator physics (Nadolski, Laurent S.); 4 - Presentation of Paris' master diplomas in big instruments (Kazamias, Sophie); 5 - Particle accelerators and European Union's projects (Vretenar, Maurizio); 6 - French research infrastructures (Ferrando, Philippe); 7 - Coordination of accelerators activity in France (Laune, Bernard; Vedrine, Pierre)

  1. Accelerator reliability workshop

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, L; Duru, Ph; Koch, J M; Revol, J L; Van Vaerenbergh, P; Volpe, A M; Clugnet, K; Dely, A; Goodhew, D

    2002-07-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop.

  2. Accelerator reliability workshop

    International Nuclear Information System (INIS)

    Hardy, L.; Duru, Ph.; Koch, J.M.; Revol, J.L.; Van Vaerenbergh, P.; Volpe, A.M.; Clugnet, K.; Dely, A.; Goodhew, D.

    2002-01-01

    About 80 experts attended this workshop, which brought together all accelerator communities: accelerator driven systems, X-ray sources, medical and industrial accelerators, spallation sources projects (American and European), nuclear physics, etc. With newly proposed accelerator applications such as nuclear waste transmutation, replacement of nuclear power plants and others. Reliability has now become a number one priority for accelerator designers. Every part of an accelerator facility from cryogenic systems to data storage via RF systems are concerned by reliability. This aspect is now taken into account in the design/budget phase, especially for projects whose goal is to reach no more than 10 interruptions per year. This document gathers the slides but not the proceedings of the workshop

  3. Acceleration of radioactive ions

    International Nuclear Information System (INIS)

    Laxdal, R.E.

    2003-01-01

    There is an intense interest world-wide in the use of radioactive ion beams (RIBs) for experiment. In many existing or proposed facilities ions are produced or collected at source potential, ionized and re-accelerated. Within the past year three new ISOL based facilities have added dedicated post-accelerators to deliver accelerated RIBs to experiment. The paper gives an overview of RIB accelerators present and future, and explores the inherent features in the various acceleration methods with an emphasis on heavy ion linacs. The ISAC-I and ISAC-II post-accelerators are discussed as examples. Commissioning results and initial operating experience with ISAC-I will be presented

  4. Nuclear physics accelerator facilities

    International Nuclear Information System (INIS)

    1988-12-01

    This paper describes many of the nuclear physics heavy-ion accelerator facilities in the US and the research programs being conducted. The accelerators described are: Argonne National Laboratory--ATLAS; Brookhaven National Laboratory--Tandem/AGS Heavy Ion Facility; Brookhaven National Laboratory--Relativistic Heavy Ion Collider (RHIC) (Proposed); Continuous Electron Beam Accelerator Facility; Lawrence Berkeley Laboratory--Bevalac; Lawrence Berkeley Laboratory--88-Inch Cyclotron; Los Alamos National Laboratory--Clinton P. Anderson Meson Physics Facility (LAMPF); Massachusetts Institute of Technology--Bates Linear Accelerator Center; Oak Ridge National Laboratory--Holifield Heavy Ion Research Facility; Oak Ridge National Laboratory--Oak Ridge Electron Linear Accelerator; Stanford Linear Accelerator Center--Nuclear Physics Injector; Texas AandM University--Texas AandM Cyclotron; Triangle Universities Nuclear Laboratory (TUNL); University of Washington--Tandem/Superconducting Booster; and Yale University--Tandem Van de Graaff

  5. Accelerated leach test development program

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Pietrzak, R.F.; Heiser, J.; Franz, E.M.; Colombo, P.

    1990-11-01

    In FY 1989, a draft accelerated leach test for solidified waste was written. Combined test conditions that accelerate leaching were validated through experimental and modeling efforts. A computer program was developed that calculates test results and models leaching mechanisms. This program allows the user to determine if diffusion controls leaching and, if this is the case, to make projections of releases. Leaching mechanisms other than diffusion (diffusion plus source term partitioning and solubility limited leaching) are included in the program is indicators of other processes that may control leaching. Leach test data are presented and modeling results are discussed for laboratory scale waste forms composed of portland cement containing sodium sulfate salt, portland cement containing incinerator ash, and vinyl ester-styrene containing sodium sulfate. 16 refs., 38 figs., 5 tabs

  6. External Measures of Cognition

    Directory of Open Access Journals (Sweden)

    Osvaldo eCairo

    2011-10-01

    Full Text Available The human brain is undoubtedly the most impressive, complex and intricate organ that has evolved over time. It is also probably the least understood, and for that reason, the one that is currently attracting the most attention. In fact, the number of comparative analyses that focus on the evolution of brain size in Homo sapiens and other species has increased dramatically in recent years. In neuroscience, no other issue has generated so much interest and been the topic of so many heated debates as the difference in brain size between socially defined population groups, both its connotations and implications. For over a century, external measures of cognition have been related to intelligence. However, it is still unclear whether these measures actually correspond to cognitive abilities. In summary, this paper must be reviewed with this premise in mind.

  7. Hanford External Dosimetry Program

    International Nuclear Information System (INIS)

    Fix, J.J.

    1990-10-01

    This document describes the Hanford External Dosimetry Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy (DOE) and its Hanford contractors. Program services include administrating the Hanford personnel dosimeter processing program and ensuring that the related dosimeter data accurately reflect occupational dose received by Hanford personnel or visitors. Specific chapters of this report deal with the following subjects: personnel dosimetry organizations at Hanford and the associated DOE and contractor exposure guidelines; types, characteristics, and procurement of personnel dosimeters used at Hanford; personnel dosimeter identification, acceptance testing, accountability, and exchange; dosimeter processing and data recording practices; standard sources, calibration factors, and calibration processes (including algorithms) used for calibrating Hanford personnel dosimeters; system operating parameters required for assurance of dosimeter processing quality control; special dose evaluation methods applied for individuals under abnormal circumstances (i.e., lost results, etc.); and methods for evaluating personnel doses from nuclear accidents. 1 ref., 14 figs., 5 tabs

  8. Bevalac external beamline optics

    Energy Technology Data Exchange (ETDEWEB)

    Kalnins, J.G.; Krebs, G.F.; Tekawa, M.M.; Alonso, J.R.

    1987-04-01

    This handbook is intended as an aid for tuning the external particle beam (EPB) lines at the Lawrence Berkeley Laboratory's Bevalac. The information contained within will be useful to the Bevalac's Main Control Room and experimenters alike. First, some general information is given concerning the EPB lines and beam optics. Next, each beam line is described in detail: schematics of the beam line components are shown, all the variables required to run a beam transport program are presented, beam envelopes are given with wire chamber pictures and magnet currents, focal points and magnifications. Some preliminary scaling factors are then presented which should aid in choosing a given EPB magnet's current for a given central Bevalac field. Finally, some tuning hints are suggested.

  9. Bevalac external beamline optics

    International Nuclear Information System (INIS)

    Kalnins, J.G.; Krebs, G.F.; Tekawa, M.M.; Alonso, J.R.

    1987-04-01

    This handbook is intended as an aid for tuning the external particle beam (EPB) lines at the Lawrence Berkeley Laboratory's Bevalac. The information contained within will be useful to the Bevalac's Main Control Room and experimenters alike. First, some general information is given concerning the EPB lines and beam optics. Next, each beam line is described in detail: schematics of the beam line components are shown, all the variables required to run a beam transport program are presented, beam envelopes are given with wire chamber pictures and magnet currents, focal points and magnifications. Some preliminary scaling factors are then presented which should aid in choosing a given EPB magnet's current for a given central Bevalac field. Finally, some tuning hints are suggested

  10. SPS RF Accelerating Cavity

    CERN Multimedia

    1979-01-01

    This picture shows one of the 2 new cavities installed in 1978-1979. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412016X, 7412017X, 7411048X

  11. Japan Accelerator Conference

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    At the international level, the high energy accelerator scene evolves rapidly and the International Conference on High Energy Accelerators is where its strong pulse can best be felt. This year, the Conference was held for the first time in Japan, with the 14th meeting in the series having been hosted in August by the Japanese KEK National Laboratory for High Energy Physics, Tsukuba. The venue was a recognition of the premier accelerator physics and technology status achieved by this diligent nation

  12. Accelerator shielding benchmark problems

    International Nuclear Information System (INIS)

    Hirayama, H.; Ban, S.; Nakamura, T.

    1993-01-01

    Accelerator shielding benchmark problems prepared by Working Group of Accelerator Shielding in the Research Committee on Radiation Behavior in the Atomic Energy Society of Japan were compiled by Radiation Safety Control Center of National Laboratory for High Energy Physics. Twenty-five accelerator shielding benchmark problems are presented for evaluating the calculational algorithm, the accuracy of computer codes and the nuclear data used in codes. (author)

  13. Plasma particle accelerators

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1988-01-01

    The Superconducting Supercollider (SSC) will require an 87-kilometer accelerator ring to boost particles to 40 TeV. The SSC's size is due in part to the fact that its operating principle is the same one that has dominated accelerator design for 50 years: it guides particles by means of magnetic fields and propels them by strong electric fields. If one were to build an equally powerful but smaller accelerator, one would need to increase the strength of the guiding and propelling fields. Actually, however, conventional technology may not be able to provide significant increases in field strength. There are two reasons. First, the forces from magnetic fields are becoming greater than the structural forces that hold a magnetic material together; the magnets that produce these fields would themselves be torn apart. Second, the energy from electric fields is reaching the energies that bind electrons to atoms; it would tear electrons from nuclei in the accelerator's support structures. It is the electric field problem that plasma accelerators can overcome. Plasma particle accelerators are based on the principle that particles can be accelerated by the electric fields generated within a plasma. Because the plasma has already been ionized, plasma particle accelerators are not susceptible to electron dissociation. They can in theory sustain accelerating fields thousands of times stronger that conventional technologies. So far two methods for creating plasma waves for accelerators have been proposed and tested: the wakefield and the beat wave. Although promising electric fields have been produced, more research is necessary to determine whether plasma particle accelerators can compete with the existing accelerators. 7 figs

  14. Wake field accelerators

    International Nuclear Information System (INIS)

    Wilson, P.B.

    1986-02-01

    In a wake field accelerator a high current driving bunch injected into a structure or plasma produces intense induced fields, which are in turn used to accelerate a trailing charge or bunch. The basic concepts of wake field acceleration are described. Wake potentials for closed cavities and periodic structures are derived, as are wake potentials on a collinear path with a charge distribution. Cylindrically symmetric structures excited by a beam in the form of a ring are considered

  15. CONFERENCE: Computers and accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-01-15

    In September of last year a Conference on 'Computers in Accelerator Design and Operation' was held in West Berlin attracting some 160 specialists including many from outside Europe. It was a Europhysics Conference, organized by the Hahn-Meitner Institute with Roman Zelazny as Conference Chairman, postponed from an earlier intended venue in Warsaw. The aim was to bring together specialists in the fields of accelerator design, computer control and accelerator operation.

  16. Japan Accelerator Conference

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1989-11-15

    At the international level, the high energy accelerator scene evolves rapidly and the International Conference on High Energy Accelerators is where its strong pulse can best be felt. This year, the Conference was held for the first time in Japan, with the 14th meeting in the series having been hosted in August by the Japanese KEK National Laboratory for High Energy Physics, Tsukuba. The venue was a recognition of the premier accelerator physics and technology status achieved by this diligent nation.

  17. CERN Accelerator School

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    The CERN Accelerator School (CAS) recently held its Advanced Accelerator Physics course in Greece on the island of Rhodes. Complementing the general course in Finland last year, this course was organized together with the University of Athens and NCSR. Demokritos. Accelerator specialists from Europe, CIS, Japan and USA followed two weeks of ''state-of-theart'' lectures designed to complete their education in the field

  18. Resonant High Power Combiners