WorldWideScience

Sample records for column extraction chromatography

  1. Inert carriers for column extraction chromatography

    International Nuclear Information System (INIS)

    Katykhin, G.S.

    1978-01-01

    Inert carriers used in column extraction chromatography are reviewed. Such carriers are devided into two large groups: hydrophilic carriers which possess high surface energy and are well wetted only with strongly polar liquids (kieselguhrs, silica gels, glasses, cellulose, Al 2 O 3 ) and water-repellent carriers which possess low surface energy and are well wetted with various organic solvents (polyethylene, polytetrafluorethylene polytrifluorochlorethylene). Properties of various carriers are presented: structure, chemical and radiation stability, adsorption properties, extracting agent capacity. The effect of structure and sizes of particles on the efficiency of chromatography columns is considered. Ways of immovable phase deposition on the carrier and the latter's regeneration. Peculiarities of column packing for preparative and continuous chromatography are discussed

  2. Use of laminar chromatographic methods for determination of separation conditions in column extraction chromatography

    International Nuclear Information System (INIS)

    Ghersini, G.; Cerrai, E.

    1978-01-01

    Possibilities of using laminar chromatographic methods (paper and thin-layer chromatography) to determine optimal separation conditions in column extraction chromatography are analysed. Most of the given laminar methods are presented as Rf-spectra, i.e. as dependences of Rf found experimentally on eluating solution component concentration. Interrelation between Rf and distribution coefficients of corresponding liquid extraction systems and retention volumes of chromatographic columns is considered. Literature data on extraction paper and thin-layer chromatography of elements with various immovable phases are presented

  3. High-throughput liquid chromatography for drug analysis in biological fluids: investigation of extraction column life.

    Science.gov (United States)

    Zeng, Wei; Fisher, Alison L; Musson, Donald G; Wang, Amy Qiu

    2004-07-05

    A novel method was developed and assessed to extend the lifetime of extraction columns of high-throughput liquid chromatography (HTLC) for bioanalysis of human plasma samples. In this method, a 15% acetic acid solution and 90% THF were respectively used as mobile phases to clean up the proteins in human plasma samples and residual lipids from the extraction and analytical columns. The 15% acetic acid solution weakens the interactions between proteins and the stationary phase of the extraction column and increases the protein solubility in the mobile phase. The 90% THF mobile phase prevents the accumulation of lipids and thus reduces the potential damage on the columns. Using this novel method, the extraction column lifetime has been extended to about 2000 direct plasma injections, and this is the first time that high concentration acetic acid and THF are used in HTLC for on-line cleanup and extraction column lifetime extension.

  4. Evaluation of phytochemical screening & extraction of lycopene from Citrullus lanatus by using column chromatography

    OpenAIRE

    lalitha govindaraj; Suseela vivek

    2015-01-01

    The present study focused on the phytochemical constituents, isolation of lycopene of the Citrullus lanatusis fruits which were collected from the local market in around sulur area, India. The phytochemical analysis of fruit extracts revealed the presence of   bioactive compounds such as phenolics, alkaloids, saponins, tannins, steroids and flavonoids in the extract. The isolation of lycopene were quantified by using column chromatography that depicted (lycopene - 68.0285 mg/k fresh wt) respe...

  5. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

    International Nuclear Information System (INIS)

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat,; Suzery, Meiny

    2015-01-01

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r 2 =0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel

  6. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

    Energy Technology Data Exchange (ETDEWEB)

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat,; Suzery, Meiny [Organic Chemistry Laboratory, Departement of Chemistry, Diponegoro University Jln Prof. Soedharto SH, Tembalang, Semarang 50275, Indonesia Tel / Fax: (024) 7460058 (Indonesia)

    2015-12-29

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r{sup 2}=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

  7. Column chromatography isolation of nicotine from tobacco leaf extract (Nicotiana tabaccum L.)

    Science.gov (United States)

    Fathi, Raden Muhammad; Fauzantoro, Ahmad; Rahman, Siti Fauziyah; Gozan, Misri

    2018-02-01

    Restrictions on the use of dried tobacco leaf for cigarette production must be accompanied by the development of non-cigarette alternative products that are made from tobacco leaves. One of the alternative that can be done is to use the nicotine compound in tobacco leaf extract as medical product, such as Parkinson's medication or to be used as active substance in biopesticide. Nicotine was isolated using column chromatography method with the variation of mobile phase mixture ratio (petroleum ether and ethanol), started from 8:2, 6:4, 4:6, 2:8, to 0:10. All of the chromatographic fraction from each mobile phase's ratio was then tested qualitatively using thin layer chromatography (TLC) and also quantitatively using HPLC instrument. The column chromatography process could isolate 4.006% of nicotine compound from 4.19% tobacco leaf extract's nicotine. It is also known that ethanol is a good solution to be used as chromatography's mobile phase for nicotine isolation from tobacco leaf extract.

  8. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  9. Simple, specific analysis of organophosphorus and carbamate pesticides in sediments using column extraction and gas chromatography

    Science.gov (United States)

    Belisle, A.A.; Swineford, D.M.

    1988-01-01

    A simple, specific procedure was developed for the analysis of organophosphorus and carbamate pesticides in sediment. The wet soil was mixed with anhydrous sodium sulfate to bind water and the residues were column extracted in acetone:methylene chloride (1:l,v/v). Coextracted water was removed by additional sodium sulfate packed below the sample mixture. The eluate was concentrated and analyzed directly by capillary gas chromatography using phosphorus and nitrogen specific detectors. Recoveries averaged 93 % for sediments extracted shortly after spiking, but decreased significantly as the samples aged.

  10. Column extraction chromatography with HEH (EHP) for separating rare earth elements from coexistent elements and its application

    International Nuclear Information System (INIS)

    Peng Chunlin; Sun Baocheng; Zhao Junwu; Liu Xuan

    1985-01-01

    For separating rare earths from large amount of coexistent elements a new method of column extraction chromatography with HEH (EHP) as a stationary phase and sulphosalicylic acid, gluconic acid, ascorbic acid respectively as a mobile phase has been developed. It has been applied to the determination of trace rare earth elements in nickel-base alloys and iron-nickel-base alloys with satisfactory results

  11. Development of immunoaffinity columns for pyraclostrobin extraction from fruit juices and analysis by liquid chromatography with UV detection.

    Science.gov (United States)

    Esteve-Turrillas, Francesc A; Mercader, Josep V; Agulló, Consuelo; Abad-Somovilla, Antonio; Abad-Fuentes, Antonio

    2011-07-29

    Pyraclostrobin belongs to a new generation of fungicides widely used to preserve high valuable crops. In the present study, three monoclonal antibodies with different affinities to this modern strobilurin have been evaluated for their usefulness in the production of immunoaffinity columns suitable for the solid-phase extraction, concentration, and clean-up of residues from food commodities. Different immunosorbents were produced and characterized in terms of antibody immobilization efficiency, immunosorbent binding capacity, optimum elution conditions, and reusability. Covalent coupling of the antibodies to Sepharose-CNBr gel took place with high yield (over 90%), whereas the immunosorbent efficacy to retain the analyte (from 28 to 68%) was shown to depend on the amount and type of antibody immobilized on the support. As a matter of fact, columns prepared with the monoclonal antibody PYs5#14 were able to selectively bound up to 53 μg of pyraclostrobin per gram of beads. Acetonitrile solutions were preferred over methanolic ones for analyte elution, and some immunosorbents could be reused at least 4-6 times provided that the amount of pyraclostrobin and the volume of sample did not overload the column. Effectiveness of the selected immunoaffinity column was evidenced by the development of an extraction procedure for pyraclostrobin residues from fruit juices and further determination by high-performance liquid chromatography with UV detection. A concentration factor of 50 times was achieved with the developed immunoaffinity column, which eventually resulted in a limit of quantification of 0.01 mg L(-1). Finally, quantitative recoveries were obtained on apple juice and red grape must samples spiked with pyraclostrobin from 0.01 to 1 mg L(-1). Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Phytochemical analysis of ethanolic extract of Dichrostachys Cinerea W and Arn leaves by a thin layer chromatography, high performance thin layer chromatography and column chromatography

    OpenAIRE

    M Vijayalakshmi; K Periyanayagam; K Kavitha; K Akilandeshwari

    2013-01-01

    Background: The leaves of Dichrostachys cinerea are used as laxative, diuretic, painkiller. It is also used in the treatment of gonorrhoea, boils, oedema, gout, veneral diseases and nasopharyngeal affections, etc. Materials and Methods: The Phytochemical investigation of ethanolic extract of D. cinerea leaves were performed by standard chemical tests, thin layer chromatography (TLC) by using various solvent systems, and by high performance liquid chromatography (HPTLC). Two compounds were...

  13. Separation of the Components of a Commercial Analgesic Tablet: A Two-Week Sequence Comparing Purification by Two-Base Extraction and Column Chromatography

    Science.gov (United States)

    Revell, Kevin D.

    2011-01-01

    A new laboratory experiment is described in which students compare two benchtop separation methods to isolate the three active components of the commercial analgesic Excedrin. In the two-week sequence, aspirin, acetaminophen, and caffeine are separated using either a two-base liquid-liquid extraction or silica column chromatography. Students then…

  14. Online hyphenation of extraction, Sephadex LH-20 column chromatography, and high-speed countercurrent chromatography: A highly efficient strategy for the preparative separation of andrographolide from Andrographis paniculata in a single step.

    Science.gov (United States)

    Zhang, Ying-Qi; Wang, Shan-Shan; Han, Chao; Xu, Jin-Fang; Luo, Jian-Guang; Kong, Ling-Yi

    2017-12-01

    A novel isolation strategy, online hyphenation of ultrasonic extraction, Sephadex LH-20 column chromatography combined with high-speed countercurrent chromatography, was developed for pure compounds extraction and purification. Andrographolide from Andrographis paniculata was achieved only in a single step purification protocol via the present strategy. The crude powder was ultrasonic extracted and extraction was pumped into Sephadex LH-20 column directly to cut the nontarget fractions followed by the second-dimensional high-speed countercurrent chromatography, hyphenated by a six-port valve equipped at the post-end of Sephadex LH-20 column, for the final purification. The results yielded andrographolide with the amount of 1.02 mg and a purity of 98.5% in a single step, indicating that the present method is effective to harvest target compound from medicinal plant. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Online micro-solid-phase extraction based on boronate affinity monolithic column coupled with high-performance liquid chromatography for the determination of monoamine neurotransmitters in human urine.

    Science.gov (United States)

    Yang, Xiaoting; Hu, Yufei; Li, Gongke

    2014-05-16

    Quantification of monoamine neurotransmitters is very important in diagnosing and monitoring of patients with neurological disorders. We developed an online analytical method to selectively determine urinary monoamine neurotransmitters, which coupled the boronate affinity monolithic column micro-solid-phase extraction with high-performance liquid chromatography (HPLC). The boronate affinity monolithic column was prepared by in situ polymerization of vinylphenylboronic acid (VPBA) and N,N'-methylenebisacrylamide (MBAA) in a stainless capillary column. The prepared monolithic column showed good permeability, high extraction selectivity and capacity. The column-to-column reproducibility was satisfactory and the enrichment factors were 17-243 for four monoamine neurotransmitters. Parameters that influence the online extraction efficiency, including pH of sample solution, flow rate of extraction and desorption, extraction volume and desorption volume were investigated. Under the optimized conditions, the developed method exhibited low limit of detection (0.06-0.80μg/L), good linearity (with R(2) between 0.9979 and 0.9993). The recoveries in urine samples were 81.0-105.5% for four monoamine neurotransmitters with intra- and inter-day RSDs of 2.1-8.2% and 3.7-10.6%, respectively. The online analytical method was sensitive, accurate, selective, reliable and applicable to analysis of trace monoamine neurotransmitters in human urine sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Improvements in solvent extraction columns

    International Nuclear Information System (INIS)

    Aughwane, K.R.

    1987-01-01

    Solvent extraction columns are used in the reprocessing of irradiated nuclear fuel. For an effective reprocessing operation a solvent extraction column is required which is capable of distributing the feed over most of the column. The patent describes improvements in solvent extractions columns which allows the feed to be distributed over an increased length of column than was previously possible. (U.K.)

  17. Solvent extraction columns

    International Nuclear Information System (INIS)

    Middleton, P.; Smith, J.R.

    1979-01-01

    In pulsed columns for use in solvent extraction processes, e.g. the reprocessing of nuclear fuel, the horizontal perforated plates inside the column are separated by interplate spacers manufactured from metallic neutron absorbing material. The spacer may be in the form of a spiral or concentric circles separated by radial limbs, or may be of egg-box construction. Suitable neutron absorbing materials include stainless steel containing boron or gadolinium, hafnium metal or alloys of hafnium. (UK)

  18. High-Efficiency On-Line Solid-Phase Extraction Coupling to 15-150 um I.D. Column Liquid Chromatography for Proteomic Analysis

    International Nuclear Information System (INIS)

    Shen, Yufeng; Moore, Ronald J.; Zhao, Rui; Blonder, Josip; Auberry, Deanna L.; Masselon, Christophe D.; Pasa Tolic, Ljiljana; Hixson, Kim K.; Auberry, Kenneth J.; Smith, Richard D.

    2003-01-01

    Flexible manipulation of various properties of proteomic samples is important for proteomic analyses, but it has been little explored for newly developed approaches based on liquid chromatography (LC) in combination with mass spectrometry (MS). With miniaturization of the LC column inner diameter dimensions (required for improving the analysis sensitivity), this issue becomes more challenging due to the small flow rates and the increasing effects of extra column volume on the separation quality and its use for resolving complex proteomic mixtures. In this study, we used commercial switching valves (150-mm channels) to implement the on-line coupling of capillary LC columns with relatively large solid phase extraction (SPE) columns operated at 10,000 psi. With optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained with peak capacities of ∼1000 for capillaries having inner diameters between 15 to 150 mm. The on-line coupled SPE columns increased the sample processing capabilities by ∼400-fold for sample solution volume and ∼10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Used with an ion trap tandem MS we could typically identify 1100-1500 peptides for analyses in a single 5-hour run. Peptides extracted on the SPE column and eluted from the LC column covered a hydrophilicity/hydrophobicity range that include an estimated ∼98% of all the tryptic peptides. The present implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for routine proteomic analyses.

  19. Rapid trace level determination of sulfonamide residues in honey with online extraction using short C-18 column by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Sajid, Muhammad; Na, Na; Safdar, Muhammad; Lu, Xin; Ma, Lin; He, Lan; Ouyang, Jin

    2013-11-01

    A sensitive and inexpensive quantification method with online extraction using a short C-18 column for sulfonamide residues in honey by high performance liquid chromatography with fluorescence detector was developed and validated. In sample preparation, acid hydrolysis was used to break the N-glycoside bond between the honey sugar and sulfonamide drugs and derivatization of sulfonamide residues with fluorescamine was conducted at pH 3.5 using a citrate buffer (0.5M) in the honey matrix. The chromatography was carried out on Zorbax Extended C-18 (250mm×4.6mm; 5μm) column, using a mixture of acetonitrile and an acetate buffer (pH 4.50, 20mM) as a mobile phase. A Zorbax Extended C-18 (12mm×4.6mm; 5μm) column was used for online extraction of fifteen sulfonamide residues from honey sample with the help of a two position valve. The limit of quantification of sulfonamide residues in honey was less than 3ngg(-1), and the percentage recovery of study compounds in spiked honey sample was from 80% for sulfacetamide to 100% of sulfachloropyridazine. The developed method has excellent linearity for all studied sulfonamides with a correlation coefficient 0.993. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Determination of Wastewater Compounds in Sediment and Soil by Pressurized Solvent Extraction, Solid-Phase Extraction, and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Burkhardt, Mark R.; Zaugg, Steven D.; Smith, Steven G.; ReVello, Rhiannon C.

    2006-01-01

    A method for the determination of 61 compounds in environmental sediment and soil samples is described. The method was developed in response to increasing concern over the effects of endocrine-disrupting chemicals in wastewater and wastewater-impacted sediment on aquatic organisms. This method also may be used to evaluate the effects of combined sanitary and storm-sewer overflow on the water and sediment quality of urban streams. Method development focused on the determination of compounds that were chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Sediment and soil samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from interfering matrix components by high-pressure water/isopropyl alcohol extraction. The compounds were isolated using disposable solid-phase extraction (SPE) cartridges containing chemically modified polystyrene-divinylbenzene resin. The cartridges were dried with nitrogen gas, and then sorbed compounds were eluted with methylene chloride (80 percent)-diethyl ether (20 percent) through Florisil/sodium sulfate SPE cartridge, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-sand samples fortified at 4 to 72 micrograms averaged 76 percent ?13 percent relative standard deviation for all method compounds. Initial method reporting levels for single-component compounds ranged from 50 to 500 micrograms per kilogram. The concentrations of 20 out of 61 compounds initially will be reported as estimated with the 'E' remark code for one of three reasons: (1) unacceptably low-biased recovery (less than 60 percent) or highly variable method performance

  1. Fast analysis of capsaicinoids in Naga Jolokia extracts (Capsicum chinense) by high-performance liquid chromatography using fused core columns.

    Science.gov (United States)

    Stipcovich, Tea; Barbero, Gerardo F; Ferreiro-González, Marta; Palma, Miguel; Barroso, Carmelo G

    2018-01-15

    A rapid high-performance liquid chromatography method with a C18 reverse-phase fused-core column has been developed for the determination and quantification of the main capsaicinoids (nornordihydrocapsaicin, nordihydrocapsaicin, capsaicin, dihydrocapsaicin, homocapsaicin and homodihydrocapsaicin) present in Naga Jolokia peppers. A fused-core Kinetex™ C18 column (50×2.1mm i.d.; 2.6μm) was used for the analysis. The chromatographic separation was obtained with a gradient method in which the mobile phase was water (0.1% acetic acid) as solvent A and acetonitrile (0.1% acetic acid) as solvent B. The separation of all compounds was achieved in less than 3min with a total analysis time (sample-to-sample) of 10min. The robustness of the method was evaluated. The method showed excellent repeatability and intermediate precision expressed as coefficient of variance of less than 2%. The developed method was employed for the quantification of the major capsaicinoids present in different peppers and commercial products containing chilli peppers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Microwave assisted solvent extraction and coupled-column reversed-phase liquid chromatography with UV detection use of an analytical restricted-access-medium column for the efficient multi-residue analysis of acidic pesticides in soils.

    Science.gov (United States)

    Hogendoom, E A; Huls, R; Dijkman, E; Hoogerbrugge, R

    2001-12-14

    A screening method has been developed for the determination of acidic pesticides in various types of soils. Methodology is based on the use of microwave assisted solvent extraction (MASE) for fast and efficient extraction of the analytes from the soils and coupled-column reversed-phase liquid chromatography (LC-LC) with UV detection at 228 nm for the instrumental analysis of uncleaned extracts. Four types of soils, including sand, clay and peat, with a range in organic matter content of 0.3-13% and ten acidic pesticides of different chemical families (bentazone, bromoxynil, metsulfuron-methyl, 2,4-D, MCPA, MCPP, 2,4-DP, 2,4,5-T, 2,4-DB and MCPB) were selected as matrices and analytes, respectively. The method developed included the selection of suitable MASE and LC-LC conditions. The latter consisted of the selection of a 5-microm GFF-II internal surface reversed-phase (ISRP, Pinkerton) analytical column (50 x 4.6 mm, I.D.) as the first column in the RAM-C18 configuration in combination with an optimised linear gradient elution including on-line cleanup of sample extracts and reconditioning of the columns. The method was validated with the analysis of freshly spiked samples and samples with aged residues (120 days). The four types of soils were spiked with the ten acidic pesticides at levels between 20 and 200 microg/kg. Weighted regression of the recovery data showed for most analyte-matrix combinations, including freshly spiked samples and aged residues, that the method provides overall recoveries between 60 and 90% with relative standard deviations of the intra-laboratory reproducibility's between 5 and 25%; LODs were obtained between 5 and 50 microg/kg. Evaluation of the data set with principal component analysis revealed that the parameters (i) increase of organic matter content of the soil samples and (ii) aged residues negatively effect the recovery of the analytes.

  3. Simultaneous multi-mycotoxin determination in nutmeg by ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection.

    Science.gov (United States)

    Kong, Wei-Jun; Liu, Shu-Yu; Qiu, Feng; Xiao, Xiao-He; Yang, Mei-Hua

    2013-05-07

    A simple and sensitive analytical method based on ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with high performance liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection (USLE-IAC-HPLC-PCD-FLD) has been developed for simultaneous multi-mycotoxin determination of aflatoxins B1, B2, G1, G2 (AFB1, AFB2, AFG1, AFG2) and ochratoxin A (OTA) in 13 edible and medicinal nutmeg samples marketed in China. AFs and OTA were extracted from nutmeg samples by ultrasonication using a methanol : water (80 : 20, v/v) solution, followed by an IAC clean-up step. Different USL extraction conditions, pre-processing ways for nutmeg sample and clean-up columns for mycotoxins, as well as HPLC-PCD-FLD parameters (mobile phase, column temperature, elution procedure, excitation and emission wavelengths) were optimized. This method, which was appraised for analyzing nutmeg samples, showed satisfactory results with reference to limits of detection (LODs) (from 0.02 to 0.25 μg kg(-1)), limits of quantification (LOQs) (from 0.06 to 0.8 μg kg(-1)), linear ranges (up to 30 ng mL(-1) for AFB1, AFG1 and OTA and 9 ng mL(-1) for AFB2 and AFG2), intra- and inter-day variability (all application of developed method in nutmeg samples have elucidated that four samples were detected with contamination of AFs and one with OTA. AFB1 was the most frequently found mycotoxin in 30.8% of nutmeg samples at contamination levels of 0.73-16.31 μg kg(-1). At least two different mycotoxins were co-occurred in three samples, and three AFs were simultaneously detected in one sample.

  4. Extraction chromatography of actinides

    International Nuclear Information System (INIS)

    Muller, W.

    1978-01-01

    Extraction chromatography of actinides in the oxidation state from 2 to 6 is reviewed. Data on using neutral (tbp), basic (substituted ammonium salts) and acidic [di-(2-ethylhexyl)-phosphoric acid (D2EHPA)] extracting agents ketones, esters, alcohols and β-diketones in this method are given. Using the example of actinide separation using D2EHPA, discussed are factors influencing the efficiency of their chromatography separation (nature and particle size of the carrier materials, extracting agents amount on the carrier, temperature and elution rate)

  5. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  6. Use of macroporous plastics in extraction chromatography

    International Nuclear Information System (INIS)

    Braun, T.; Farac, A.B.

    1978-01-01

    Possibilities are analysed which the use of porous plastics (polyvinyl chloride, siloxane rubber, polyurethane, polystyrene and etc.) as carriers presents in extraction chromatography. Short characteristics of chemical and physical properties of macroporous carriers is given. The importance of correct chromatographic column packing is noted to obtain columns with good hydrodynamic characteristics and operational properties. Examples of using columns with macroporous carriers in radiochemistry and inorganic chemistry for element separation are given

  7. Bibliography of extraction chromatography, ch. 15

    International Nuclear Information System (INIS)

    Eschrich, H.; Drent, W.

    1975-01-01

    A bibliography of reviews, books and publications dealing with laminar extraction chromatography is given. A tabular survey of experimental data on column extraction chromatographic investigations, stationary phases and support materials is presented. An author index and corporative author index are included. This bibliography refers to various publications relevant to nuclear interest

  8. LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Thornton, J.D.

    1957-12-31

    This patent relates to liquid-liquid extraction columns having a means for pulsing the liquid in the column to give it an oscillatory up and down movement, and consists of a packed column, an inlet pipe for the dispersed liquid phase and an outlet pipe for the continuous liquid phase located in the direct communication with the liquid in the lower part of said column, an inlet pipe for the continuous liquid phase and an outlet pipe for the dispersed liquid phase located in direct communication with the liquid in the upper part of said column, a tube having one end communicating with liquid in the lower part of said column and having its upper end located above the level of said outlet pipe for the dispersed phase, and a piston and cylinder connected to the upper end of said tube for applying a pulsating pneumatic pressure to the surface of the liquid in said tube so that said surface rises and falls in said tube.

  9. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.

    Science.gov (United States)

    Schweiger, Susanne; Hinterberger, Stephan; Jungbauer, Alois

    2017-12-08

    In the biopharmaceutical industry, pre-packed columns are the standard for process development, but they must be qualified before use in experimental studies to confirm the required performance of the packed bed. Column qualification is commonly done by pulse response experiments and depends highly on the experimental testing conditions. Additionally, the peak analysis method, the variation in the 3D packing structure of the bed, and the measurement precision of the workstation influence the outcome of qualification runs. While a full body of literature on these factors is available for HPLC columns, no comparable studies exist for preparative columns for protein chromatography. We quantified the influence of these parameters for commercially available pre-packed and self-packed columns of disposable and non-disposable design. Pulse response experiments were performed on 105 preparative chromatography columns with volumes of 0.2-20ml. The analyte acetone was studied at six different superficial velocities (30, 60, 100, 150, 250 and 500cm/h). The column-to-column packing variation between disposable pre-packed columns of different diameter-length combinations varied by 10-15%, which was acceptable for the intended use. The column-to-column variation cannot be explained by the packing density, but is interpreted as a difference in particle arrangement in the column. Since it was possible to determine differences in the column-to-column performance, we concluded that the columns were well-packed. The measurement precision of the chromatography workstation was independent of the column volume and was in a range of±0.01ml for the first peak moment and±0.007 ml 2 for the second moment. The measurement precision must be considered for small columns in the range of 2ml or less. The efficiency of disposable pre-packed columns was equal or better than that of self-packed columns. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  10. Use of chelating agents as immovable phase in extraction chromatography

    International Nuclear Information System (INIS)

    Sebesta, F.

    1978-01-01

    Extraction chromatography using chelating agents is reviewed. The theory of element extraction by chelating agents and factors influencing this process (pH, extracting agent concentration in organic phase, masking agent concentration in aqueous phase) are briefly considered. The effect of kinetic factors on the extraction chromatography process is discussed. Ways of preparing columns are emphasized. Examples of using chelating reagents in various extraction chromatography systems are given. β-Diketones, oximes, hydroxamic acids, dithizon, diethyl dithiocarbamic acid are chosen as chelating agents

  11. Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography

    International Nuclear Information System (INIS)

    Kazarian, Artaches A.; Sanz Rodriguez, Estrella; Deverell, Jeremy A.; McCord, James; Muddiman, David C.; Paull, Brett

    2016-01-01

    Wall modified photonic crystal fibre capillary columns for in-capillary micro-extraction and liquid chromatographic separations is presented. Columns contained 126 internal parallel 4 μm channels, each containing a wall bonded porous monolithic type polystyrene-divinylbenzene layer in open tubular column format (PLOT). Modification longitudinal homogeneity was monitored using scanning contactless conductivity detection and scanning electron microscopy. The multichannel open tubular capillary column showed channel diameter and polymer layer consistency of 4.2 ± 0.1 μm and 0.26 ± 0.02 μm respectively, and modification of 100% of the parallel channels with the monolithic polymer. The modified multi-channel capillaries were applied to the in-capillary micro-extraction of water samples. 500 μL of water samples containing single μg L"−"1 levels of polyaromatic hydrocarbons were extracted at a flow rate of 10 μL min"−"1, and eluted in 50 μL of acetonitrile for analysis using HPLC with fluorescence detection. HPLC LODs were 0.08, 0.02 and 0.05 μg L"−"1 for acenaphthene, anthracene and pyrene, respectively, with extraction recoveries of between 77 and 103%. The modified capillaries were also investigated briefly for direct application to liquid chromatographic separations, with the retention and elution of a standard protein (cytochrome c) under isocratic conditions demonstrated, proving chromatographic potential of the new column format, with run-to-run retention time reproducibility of below 1%. - Highlights: • Novel PS-DVB modified photonic crystal fibres for in-capillary micro-extraction. • New method for micro-extraction of PAHs and HPLC-FL detection at sub-ppb levels. • Demonstration of PS-DVB modified photonic crystal fibres for capillary bioseparations.

  12. Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian, Artaches A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Sanz Rodriguez, Estrella; Deverell, Jeremy A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); McCord, James; Muddiman, David C. [W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Paull, Brett, E-mail: Brett.Paull@utas.edu.au [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); ARC Centre of Excellence for Electromaterials Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia)

    2016-01-28

    Wall modified photonic crystal fibre capillary columns for in-capillary micro-extraction and liquid chromatographic separations is presented. Columns contained 126 internal parallel 4 μm channels, each containing a wall bonded porous monolithic type polystyrene-divinylbenzene layer in open tubular column format (PLOT). Modification longitudinal homogeneity was monitored using scanning contactless conductivity detection and scanning electron microscopy. The multichannel open tubular capillary column showed channel diameter and polymer layer consistency of 4.2 ± 0.1 μm and 0.26 ± 0.02 μm respectively, and modification of 100% of the parallel channels with the monolithic polymer. The modified multi-channel capillaries were applied to the in-capillary micro-extraction of water samples. 500 μL of water samples containing single μg L{sup −1} levels of polyaromatic hydrocarbons were extracted at a flow rate of 10 μL min{sup −1}, and eluted in 50 μL of acetonitrile for analysis using HPLC with fluorescence detection. HPLC LODs were 0.08, 0.02 and 0.05 μg L{sup −1} for acenaphthene, anthracene and pyrene, respectively, with extraction recoveries of between 77 and 103%. The modified capillaries were also investigated briefly for direct application to liquid chromatographic separations, with the retention and elution of a standard protein (cytochrome c) under isocratic conditions demonstrated, proving chromatographic potential of the new column format, with run-to-run retention time reproducibility of below 1%. - Highlights: • Novel PS-DVB modified photonic crystal fibres for in-capillary micro-extraction. • New method for micro-extraction of PAHs and HPLC-FL detection at sub-ppb levels. • Demonstration of PS-DVB modified photonic crystal fibres for capillary bioseparations.

  13. Safety operation of chromatography column system with discharging hydrogen radiolytically generated

    International Nuclear Information System (INIS)

    Watanabe, S; Sano, Y.; Nomura, K.; Koma, Y.; Okamoto, Y.

    2015-01-01

    The extraction chromatography technology is one of the promising methods for the partitioning of minor actinides (Am and Cm) from spent nuclear fuels. In the extraction chromatography system, the accumulation of hydrogen gas in the chromatography column is suspected to lead to fire or explosion. In order to prevent hazardous accidents, it is necessary to evaluate behaviors of gas radiolytically generated inside the column. In this study, behaviors of gas inside the extraction chromatography column were investigated through experiments and Computation Fluid Dynamics (CFD) simulation. N_2 gas once accumulated as bubbles in the packed bed was hardly discharged by the flow of mobile phase. However, the CFD simulation and X-ray imaging on γ-ray irradiated column revealed that during operation the hydrogen gas generated in the column was dissolved into the mobile phase without accumulation and then discharged. (authors)

  14. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  15. A simple and rapid technique for recovery of 99mTc from low specific activity (n,γ)99Mo based on solid-liquid extraction and column chromatography methodologies

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Das, Sujata Saha; Barua, Luna

    2010-01-01

    A simple and inexpensive method has been developed for the separation of 99m Tc from 99 Mo produced from the neutron activation of 98 Mo by 98 Mo(n,γ) 99 Mo nuclear reaction. The recovery of 99m Tc was performed by solid-liquid extraction based on alumina column chromatography. The overall radiochemical yield for the complete separation of 99m Tc was 85-97% (n=5). The separated Na[ 99m Tc]TcO 4 was of high radionuclidic, radiochemical and chemical purities. The method can be adopted for routine processing and use of 99m Tc in radiopharmacy operations.

  16. Impact of the uranium (VI) speciation in mineralised urines on its extraction by calix[6]arene bearing hydroxamic groups used in chromatography columns.

    Science.gov (United States)

    Baghdadi, S; Bouvier-Capely, C; Ritt, A; Peroux, A; Fevrier, L; Rebiere, F; Agarande, M; Cote, G

    2015-11-01

    Actinides determination in urine samples is part of the analyses performed to monitor internal contamination in case of an accident or a terrorist attack involving nuclear matter. Mineralisation is the first step of any of these analyses. It aims at reducing the sample volume and at destroying all organic compounds present. The mineralisation protocol is usually based on a wet ashing step, followed by actinides co-precipitation and a furnace ashing step, before redissolution and the quantification of the actinides by the appropriate techniques. Amongst the existing methods to perform the actinides co-precipitation, alkali-earth (typically calcium) precipitation is widely used. In the present work, the extraction of uranium(VI), plutonium(IV) and americium(III) from the redissolution solutions (called "mineralised urines") on calix[6]arene columns bearing hydroxamic groups was investigated as such an extraction is a necessary step before their determination by ICP-MS or alpha spectrometry. Difficulties were encountered in the transfer of uranium(VI) from raw to mineralised urines, with yield of transfer ranging between 0% and 85%, compared to about 90% for Pu and Am, depending on the starting raw urines. To understand the origin of such a difficulty, the speciation of uranium (VI) in mineralised urines was investigated by computer simulation using the MEDUSA software and the associated HYDRA database, compiled with recently published data. These calculations showed that the presence of phosphates in the "mineralised urines" leads to the formation of strong uranyl-phosphate complexes (such as UO2HPO4) which compete with the uranium (VI) extraction by the calix[6]arene bearing hydroxamic groups. The extraction constant of uranium (VI) by calix[6]arene bearing hydroxamic groups was determined in a 0.04 mol L(-1) sodium nitrate solution (logK=4.86±0.03) and implemented in an extraction model taking into account the speciation in the aqueous phase. This model allowed to

  17. Effects of column fractions on the leaves extract of Bridelia ...

    African Journals Online (AJOL)

    The in vitro antibacterial studies were carried out on both crude extracts and fractions obtained after column chromatography against medically important bacterial strains including; Escherichia coli, Staphylococcus aureus, Micrococcus species and Pseudomonas aeruginosa for different concentrations of 30mg/ml, 60mg/ml, ...

  18. Microchip-based monolithic column for high performance liquid chromatography

    Data.gov (United States)

    National Aeronautics and Space Administration — We have developed microchip based monolithic columns that can be used for liquid chromatography of small organic molecules, as well as, macromolecules such as...

  19. Measurement of dihydro testosterone by radioimmunoassay after celite column chromatography

    International Nuclear Information System (INIS)

    Lando, V.S.

    1992-01-01

    A method for measuring dihydro testosterone after celite column chromatography is developed. One milliliter of serum containing 1000 cpm of tritiated dihydro testosterone was extracted with hexane: ethyl acetate (2:3): dried, diluted with non saturated iso octane and injected in the column previously washed with 3.5 ml of pure iso octane. The serum was eluted from the column with pure iso octane (3.5 ml) followed by 5% ethyl acetate in iso octane. The quantity of tritiated dihydro testosterone which was recovered ranged from 50% to 80% in all assays. The sensitivity of the method was 4 ng/d l. The intra-assay variation was less than 9% and the inter-assay variation was less than 9,7%. It was measured dihydro testosterone, testosterone and testosterone/dihydro testosterone ratio in the following groups: Group 1- forty-one normal adult subjects in basal conditions, Group 2 - six normal adult subjects, evaluated in basal conditions and after stimulus with 6000 International Unity of human Chorionic Gonadotropin; Group 3- six pre-puberal children with unilateral cryptochidism. Group 4- eight patients with male pseudo hermaphroditism due to 5-alpha-reductase deficiency in basal conditions and after HCG. (author)

  20. Extraction chromatography of fission products

    International Nuclear Information System (INIS)

    Bonnevie-Svendsen, M.; Goon, K.

    1978-01-01

    Various cases of using extraction chromatography during analysis of fission products are reviewed. The use of the extraction chromatography method is considered while analysing reprocessed products of nuclear fuel for quantitative radiochemical analysis and control of fission product and actinoide separation during extraction and their chemical state in production solutions. The method is used to obtain pure fractions of typical burnup monitors (neodymium, molybdenum, cerium, cesium, europium, lanthanides) during determination of nuclear fuel burnup degree. While studying the nature of nuclear reactions the method is used to separate quickly short-life isotopes, to purify β-radiator fractions before measuring their half-life periods, to enrich isotopes forming with low output during fission. Examples of using extraction chromatography are given to separate long half-life or stable fission products from spent solutions, to control environment object contamination

  1. Monitoring aged reversed-phase high performance liquid chromatography columns

    NARCIS (Netherlands)

    Bolck, A; Smilde, AK; Bruins, CHP

    1999-01-01

    In this paper, a new approach for the quality assessment of routinely used reversed-phase high performance liquid chromatography columns is presented. A used column is not directly considered deteriorated when changes in retention occur. If attention is paid to the type and magnitude of the changes,

  2. Ion exchange and liquid column chromatography

    International Nuclear Information System (INIS)

    Walton, H.F.

    1980-01-01

    Major accomplishments in liquid chromatography for the past two years and reported in journals available to December 31, 1979 are reviewed. Emphasis has been placed on principles and methodology with some representative examples of application included. Applications are illustrated in two rather lenghtly tables, one covering inorganic ions and the other covering organic compounds. 544 references, 8 books, and 15 reviews are listed in the bibliography

  3. [Column chromatography purification and analysis of biodiesel by transesterification].

    Science.gov (United States)

    Liu, Yang; Yi, Huai-feng; Chen, Yu; Wu, Yu-long; Yang, Ming-de; Chen, Zeng; Tong, Jun-mao

    2012-02-01

    In the present paper, crude biodiesel prepared with sorbifolia oil as raw material by transesterification was purified by column chromatography, then the composition of biodiesel was analyzed by gas chromatography, FTIR, GC-MS and 1H NMR. Column chromatography can separate the crude biodiesel into two fractions: petroleum ether eluted fraction (A1) and methanol eluted fraction (A2). Petroleum ether eluted fraction was mainly biodiesel fraction, which was produced from sorbifolia oil by transesterification, including methyl linoleate, methyl cis-9-octadecenoate and so on; methanol eluted fraction was mainly glycerol fraction, which came from the side reaction of transesterification. The results show that the purity of refined biodiesel increased from 77.51% to 93.872, and the product recovery rate reached up to 91.04% after the purification by column chromatography. The results obtained by FTIR and 1H NMR further showed that the column chromatography can effectively improve the purity of biodiesel. This paper provides a basis for industrialization of purification of biodiesel.

  4. Column Chromatography To Obtain Organic Cation Sorption Isotherms.

    Science.gov (United States)

    Jolin, William C; Sullivan, James; Vasudevan, Dharni; MacKay, Allison A

    2016-08-02

    Column chromatography was evaluated as a method to obtain organic cation sorption isotherms for environmental solids while using the peak skewness to identify the linear range of the sorption isotherm. Custom packed HPLC columns and standard batch sorption techniques were used to intercompare sorption isotherms and solid-water sorption coefficients (Kd) for four organic cations (benzylamine, 2,4-dichlorobenzylamine, phenyltrimethylammonium, oxytetracycline) with two aluminosilicate clay minerals and one soil. A comparison of Freundlich isotherm parameters revealed isotherm linearity or nonlinearity was not significantly different between column chromatography and traditional batch experiments. Importantly, skewness (a metric of eluting peak symmetry) analysis of eluting peaks can establish isotherm linearity, thereby enabling a less labor intensive means to generate the extensive data sets of linear Kd values required for the development of predictive sorption models. Our findings clearly show that column chromatography can reproduce sorption measures from conventional batch experiments with the benefit of lower labor-intensity, faster analysis times, and allow for consistent sorption measures across laboratories with distinct chromatography instrumentation.

  5. Column chromatography as a useful step in purification of diatom pigments.

    Science.gov (United States)

    Tokarek, Wiktor; Listwan, Stanisław; Pagacz, Joanna; Leśniak, Piotr; Latowski, Dariusz

    2016-01-01

    Fucoxanthin, diadinoxanthin and diatoxanthin are carotenoids found in brown algae and most other heterokonts. These pigments are involved in photosynthetic and photoprotective reactions, and they have many potential health benefits. They can be extracted from diatom Phaeodactylum tricornutum by sonication, extraction with chloroform : methanol and preparative thin layer chromatography. We assessed the utility of an additional column chromatography step in purification of these pigments. This novel addition to the isolation protocol increased the purity of fucoxanthin and allowed for concentration of diadinoxanthin and diatoxanthin before HPLC separation. The enhanced protocol is useful for obtaining high purity pigments for biochemical studies.

  6. Development and validation of a high-performance liquid chromatography method for determination of lisinopril in human plasma by magnetic solid-phase extraction and pre-column derivatization.

    Science.gov (United States)

    Rastkari, Noushin; Ahmadkhaniha, Reza

    2018-03-01

    A sensitive, reliable and simple HPLC method was developed for the determination of lisinopril in human plasma. The method consists of extraction and clean-up steps based on magnetic solid-phase extraction and pre-column derivatization with a fluorescent reagent. The mobile phase consisted of a mixture of methanol-sodium dihydrogen phosphate (pH 3.0; 0.005 m; 75:25, v/v). The flow rate was set at 0.7 mL/min. Fluorescence detection was performed at 470nm excitation and 530nm emission wavelengths. Total chromatography run time was 5 min. The average extraction recovery of lisinopril and fluvoxamine (internal standard) was ≥82.8%. The limits of detection and quantification were determined as 1 and 3 ng/mL respectively. The method exhibited a linear calibration line over the concentration range of 3-1000 ng/mL with coefficient of determination (r 2 ) of ≥0.98. The within-run and between-run precisions were satisfactory with values of CV of 1.8-12.8% (accuracy from 99.2 to 94.7%) and 2.4-13.7% (accuracy from 99.5 to 92.2%), respectively. These developments led to considerable improvement in method sensitivity and reliability. The method was validated according to the US Food and Drug Administration guidelines. Therefore, it can be considered as a suitable method for determination of lisinopril in plasma samples. Copyright © 2017 John Wiley & Sons, Ltd.

  7. 5-O-caffeoylshikimic acid from Solanum somalense leaves: advantage of centrifugal partition chromatography over conventional column chromatography.

    Science.gov (United States)

    Chideh, Saïda; Pilard, Serge; Attoumbré, Jacques; Saguez, Robert; Hassan-Abdallah, Alshaimaa; Cailleu, Dominique; Wadouachi, Anne; Baltora-Rosset, Sylvie

    2014-09-01

    Solanum somalense leaves, used in Djibouti for their medicinal properties, were extracted by MeOH. Because of the high polyphenol and flavonoid contents of the extract, respectively, determined at 80.80 ± 2.13 mg gallic acid equivalent/g dry weight and 24.4 ± 1.01 mg quercetin equivalent/g dry weight, the isolation and purification of the main polyphenols were carried out by silica gel column chromatography and centrifugal partition chromatography. Column chromatography led to 11 enriched fractions requiring further purification, while centrifugal partition chromatography allowed the easy recovery of the main compound of the extract. In a solvent system composed of CHCl3/MeOH/H2O (9.5:10:5), 21.8 mg of this compound at 97% purity was obtained leading to a yield of 2.63%. Its structure was established as 5-O-caffeoylshikimic acid by mass spectrometry and NMR spectroscopy. This work shows that S. somalense leaves contain very high level of 5-O-caffeoylshikimic acid (0.74% dry weight), making it a potential source of production of this secondary metabolite that is not commonly found in nature but could be partly responsible of the medicinal properties of S. somalense leaves. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Wastewater Compounds by Polystyrene-Divinylbenzene Solid-Phase Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.; Barber, Larry B.; Burkhardt, Mark R.

    2002-01-01

    A method for the determination of 67 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals in wastewater on aquatic organisms. This method also may be useful for evaluating the impact of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are an indicator of wastewater or that have been chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclicaromatic hydrocarbons, and high-use domestic pesticides. Water samples are filtered to remove suspended particulate matter and then are extracted by vacuum through disposable solid-phase cartridges that contain polystyrene-divinylbenzene resin. Cartridges are dried with nitrogen gas, and then sorbed compounds are eluted with dichloromethane-diethyl ether (4:1) and determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 4 micrograms per liter averaged 74 percent ? 7 percent relative standard deviation for all method compounds. Initial method detection limits for single-component compounds (excluding hormones and sterols) averaged 0.15 microgram per liter. Samples are preserved by filtration, the addition of 60 grams NaCl, and storage at 4 degrees Celsius. The laboratory has established a sample-holding time (prior to sample extraction) of 14 days from the date of sample collection until a statistically accepted method can be used to determine the effectiveness of these sample-preservation procedures.

  9. Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography – tandem mass spectrometry

    Science.gov (United States)

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...

  10. Boron isotope fractionation in column chromatography with glucamine type fibers

    International Nuclear Information System (INIS)

    Sonoda, Akinari; Makita, Yoji; Hirotsu, Takahiro

    2008-01-01

    Glucamine type polymers have specific affinity toward boric acid and borate ion. Among them, Chelest Fiber GRY-L showed larger fractionation for boron isotopes than other polymers in our previous study. For this study, we used Chelest Fibers with different fiber lengths (1.0 mm, 0.5 mm, and 0.3 mm) as column packing materials to perform chromatographic separation of boron isotopes. The shorter fiber has larger packing density when packed into the column using a dry method. The 0.3-mm-long fiber has a larger backpressure than fibers of other lengths. Boron adsorption capacities were measured using the breakthrough operation. At this time, the 0.5-mm-long fiber showed the highest capacity. When we measured the isotope ratio profile for fibers of different length using column chromatography, 0.5-mm-long fibers displayed the highest boron isotope fractionation. The 0.5-mm-long fiber is promising as a packing material of column chromatography for boron isotope separation. We also changed operation methods. The lower eluent concentration and the slower flow rate are suitable for boron isotope separation. (author)

  11. A simple and highly sensitive on-line column extraction liquid chromatography-tandem mass spectrometry method for the determination of protein-unbound tacrolimus in human plasma samples.

    Science.gov (United States)

    Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B

    2018-04-27

    Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Fiber-based monolithic columns for liquid chromatography.

    Science.gov (United States)

    Ladisch, Michael; Zhang, Leyu

    2016-10-01

    Fiber-based monoliths for use in liquid chromatographic separations are defined by columns packed with aligned fibers, woven matrices, or contiguous fiber structures capable of achieving rapid separations of proteins, macromolecules, and low molecular weight components. A common denominator and motivating driver for this approach, first initiated 25 years ago, was reducing the cost of bioseparations in a manner that also reduced residence time of retained components while achieving a high ratio of mass to momentum transfer. This type of medium, when packed into a liquid chromatography column, minimized the fraction of stagnant liquid and resulted in a constant plate height for non-adsorbing species. The uncoupling of dispersion from eluent flow rate enabled the surface chemistry of the stationary phase to be considered separately from fluid transport phenomena and pointed to new ways to apply chemistry for the engineering of rapid bioseparations. This paper addresses developments and current research on fiber-based monoliths and explains how the various forms of this type of chromatographic stationary phase have potential to provide new tools for analytical and preparative scale separations. The different stationary phases are discussed, and a model that captures the observed constant plate height as a function of mobile phase velocity is reviewed. Methods that enable hydrodynamically stable fiber columns to be packed and operated over a range of mobile phase flow rates, together with the development of new fiber chemistries, are shown to provide columns that extend the versatility of liquid chromatography using monoliths, particularly at the preparative scale. Graphical Abstract Schematic representation of a sample mixture being separated by a rolled-stationary phase column, resulting separated peaks shown in the chromatogram.

  13. Calculation of a TBP extraction column

    International Nuclear Information System (INIS)

    Lima Soares, M.L. de.

    1973-01-01

    Problems involving the number of stages in an extraction column and the equipment needed in most aqueous methods of reprocessing of nuclear fuels were studied. A solution for the separation of uranium from fission products in a feed solution that contains these components plus nitric acid, thorium and protactinium is obtained. The program has peculiarities such as treatment of tracer components; acceptance of decontamination and recuperation factors better than the set values for the solution; occurrence of niaxima concentrations; change of key component; criterion for ending of section; corrections for interaction; input data not including concentration estimates of the raffinate and organic extract; set of limitations for the concentrations based on input data to help convergence

  14. Preparative separation of polyphenols from artichoke by polyamide column chromatography and high-speed counter-current chromatography

    International Nuclear Information System (INIS)

    Shu, Xikai; Wang, Mei; Liu, Daicheng; Wang, Daijie; Lin, Xiaojing; Liu, Jianhua; Wang, Xiao; Huang, Luqi

    2013-01-01

    An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR). (author)

  15. Preparative separation of polyphenols from artichoke by polyamide column chromatography and high-speed counter-current chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Xikai; Wang, Mei; Liu, Daicheng [College of Life Science, Shandong Normal University, Jinan, Shandong (China); Wang, Daijie; Lin, Xiaojing; Liu, Jianhua; Wang, Xiao; Huang, Luqi, E-mail: wxjn1998@126.com [Shandong Analysis and Test Center, Shandong Academy of Sciences, Jinan, Shandong (China)

    2013-09-01

    An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-{beta}-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-{beta}-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR). (author)

  16. Design and control of integrated chromatography column sequences.

    Science.gov (United States)

    Andersson, Niklas; Löfgren, Anton; Olofsson, Marianne; Sellberg, Anton; Nilsson, Bernt; Tiainen, Peter

    2017-07-01

    To increase the productivity in biopharmaceutical production, a natural step is to introduce integrated continuous biomanufacturing which leads to fewer buffer and storage tanks, smaller sizes of integrated unit operations, and full automation of the operation. The main contribution of this work is to illustrate a methodology for design and control of a downstream process based on integrated column sequences. For small scale production, for example, pre-clinical studies, integrated column sequences can be implemented on a single chromatography system. This makes for a very efficient drug development platform. The proposed methodology is composed of four steps and is governed by a set of tools, that is presented, that makes the transition from batch separations to a complete integrated separation sequence as easy as possible. This methodology, its associated tools and the physical implementation is presented and illustrated on a case study where the target protein is separated from impurities through an integrated four column sequence. This article shows that the design and control of an integrated column sequence was successfully implemented for a tertiary protein separation problem. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:923-930, 2017. © 2017 American Institute of Chemical Engineers.

  17. Measurement of bromate in bread by liquid chromatography with post-column flow reactor detection.

    Science.gov (United States)

    Himata, K; Noda, M; Ando, S; Yamada, Y

    2000-01-01

    This method is suitable for the determination of bromate residues in a variety of baked goods. The peer-verified method trial was performed on white bread, multigrain bread, and coffee cake spiked with known levels of potassium bromate. The analytical portion is extracted with deionized water to remove bromate from the bulk of the baked product. The aqueous extract is carried through a series of steps to remove co-extractives that would interfere with the liquid chromatography (LC) in the determinative step or hasten the deterioration of the LC column. The extract is filtered before passing it through a reversed-phase solid-phase extraction (SPE) column and a cation-exchange column in the silver form to remove lipids and chloride, respectively. Ultrafiltration is then used to remove proteins with molecular weights of >30,000 daltons. Finally, a cation-exchange column in the sodium form is used to remove silver ions from the extract. The determinative step uses LC with a reversed-phase column and an ion-pairing agent in the mobile phase. Detection is based on the post-column reaction of bromate with o-dianisidine to form an oxidation product that is quantitated spectrophotometrically at 450 nm. Overall agreement between the submitting and peer laboratories was quite good. For bromate levels of 10-52 ppb, overall mean recoveries were 76.9 and 78.8% for the submitting and peer laboratories, respectively. The standard deviations were higher for the results of the peer laboratory, probably because of the generally higher level of baseline noise present in the chromatograms. The results demonstrate that the method provides adequate accuracy with low-fat as well as high-fat foods. Bromate at levels as low as 5 ppb (ng/g) can be detected with the method.

  18. Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography.

    Science.gov (United States)

    Mriziq, Khaled S; Guiochon, Georges

    2008-04-11

    The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC(x), taking place along one side of the bed and the second separation would be a time-based separation, LC(t), as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC(x) x LC(t) instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

  19. Ideal versus real automated twin column recycling chromatography process.

    Science.gov (United States)

    Gritti, Fabrice; Leal, Mike; McDonald, Thomas; Gilar, Martin

    2017-07-28

    The full baseline separation of two compounds (selectivity factors αchromatography is used to confirm that the speed-resolution performance of the TCRSP is intrinsically superior to that of the single-column process. This advantage is illustrated in this work by developing an automated TCRSP for the challenging separation of two polycyclic aromatic hydrocarbon (PAH) isomers (benzo[a]anthracene and chrysene) in the reversed-phase retention mode at pressure smaller than 5000psi. The columns used are the 3.0mm×150mm column packed with 3.5μm XBridge BEH-C 18 material (α=1.010) and the 3.0mm or 4.6mm×150mm columns packed with the same 3.5μm XSelect HSST 3 material (α=1.025). The isocratic mobile phase is an acetonitrile-water mixture (80/20, v/v). Remarkably, significant differences are observed between the predicted retention times and efficiencies of the ideal TCRSP (given by the number of cycles multiplied by the retention time and efficiency of one column) and those of the real TCRSP. The fundamental explanation lies in the pressure-dependent retention of these PAHs or in the change of their partial molar volume as they are transferred from the mobile to the stationary phase. A revisited retention and efficiency model is then built to predict the actual performance of real TCRSPs. The experimental and calculated resolution data are found in very good agreement for a change, Δv m =-10cm 3 /mol, of the partial molar volume of the two PAH isomers upon transfer from the acetonitrile-water eluent mixture to the silica-C 18 stationary phase. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Group type analysis of asphalt by column liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, C.; Yang, J.; Xue, Y.; Li, Y. [Chinese Academy of Science, Taiyuan (China)

    2008-07-01

    An improved analysis method for characterization of asphalt was established. The method is based on column chromatography technique. The asphalts were separated into four groups: saturates, aromatics, resins, and asphaltenes, quantitatively. About 0.1 g of sample was required in each analysis. About 20 mL of n-heptanes was used to separate out saturates first. Then about 35 mL of n-heptanes/dichloromethane (.5, v/v) mixture was used to separate out aromatics. About 30 mL of dichloromethane/tetrahydrofuran (1/3, v/v) mixture was used to separate out resin. The quality of the separation was confirmed by infrared spectra (IR) and {sup 1}H NMR analysis. The model compounds, tetracosan for saturates, dibenz(o)anthracen for aromatics, and acetanilide for resins were used for verification. The IR and {sup 1}H NMR analysis of the prepared fractions from the column liquid chromatography were in good agreement that of pure reagents.

  1. Determination of zearalenone content in cereals and feedstuffs by immunoaffinity column coupled with liquid chromatography.

    Science.gov (United States)

    Fazekas, B; Tar, A

    2001-01-01

    The zearalenone content of maize, wheat, barley, swine feed, and poultry feed samples was determined by immunoaffinity column cleanup followed by liquid chromatography (IAC-LC). Samples were extracted in methanol-water (8 + 2, v/v) solution. The filtered extract was diluted with distilled water and applied to immunoaffinity columns. Zearalenone was eluted with methanol, dried by evaporation, and dissolved in acetonitrile-water (3 + 7, v/v). Zearalenone was separated by isocratic elution of acetonitrile-water (50 + 50, v/v) on reversed-phase C18 column. The quantitative analysis was performed by fluorescence detector and confirmation was based on the UV spectrum obtained by a diode array detector. The mean recovery rate of zearalenone was 82-97% (RSD, 1.4-4.1%) on the original (single-use) immunoaffinity columns. The limit of detection of zearalenone by fluorescence was 10 ng/g at a signal-to-noise ratio of 10:1 and 30 ng/g by spectral confirmation in UV. A good correlation was found (R2 = 0.89) between the results obtained by IAC-LC and by the official AOAC-LC method. The specificity of the method was increased by using fluorescence detection in parallel with UV detection. This method was applicable to the determination of zearalenone content in cereals and other kinds of feedstuffs. Reusability of immunoaffinity columns was examined by washing with water after sample elution and allowing columns to stand for 24 h at room temperature. The zearalenone recovery rate of the regenerated columns varied between 79 and 95% (RSD, 3.2-6.3%). Columns can be regenerated at least 3 times without altering their performance and without affecting the results of repeated determinations.

  2. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    Science.gov (United States)

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  3. Separation of rare earth by column chromatography using organic resins XAD/DEPHA

    International Nuclear Information System (INIS)

    Zini, J.; Ferreira, J.C.; Bergamaschi, V.S.; Santos, I.; Carvalho, F.M.S.

    2013-01-01

    The designation of light and heavy rare earth was used the fractionation used in separation processes. In this study the process of separation of rare earth, in groups, by chromatographic column consisting in fixing of cations these elements in an organic resin Amberlite XAD16 functionalized with the extracting agent DEPHA and another portion functionalized with a mixture of extractors DEPHA/TOP. The preparation of these resins was performed in two forms, one directly as the extracting agent to the resin and the other to be used in ethyl alcohol. Conditioned resins were introduced in chromatographic columns in separation of groups, light and heavy, using a standard solution of cerium nitrate and standard solution of holmium nitrate groups to represent light and heavy respectively. The characterization technique used to identify the rare earth elements was Spectrometry X-Ray Fluorescence (XRF). The results using the technique of chromatography were satisfactory, obtaining 100% separation of the elements. (author)

  4. Separation of rare earth by column chromatography using organic resins XAD/DEPHA

    Energy Technology Data Exchange (ETDEWEB)

    Zini, J.; Ferreira, J.C.; Bergamaschi, V.S.; Santos, I.; Carvalho, F.M.S., E-mail: jcferrei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (CCCH/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Celulas a Combustivel e Hidrogenio

    2013-07-01

    The designation of light and heavy rare earth was used the fractionation used in separation processes. In this study the process of separation of rare earth, in groups, by chromatographic column consisting in fixing of cations these elements in an organic resin Amberlite XAD16 functionalized with the extracting agent DEPHA and another portion functionalized with a mixture of extractors DEPHA/TOP. The preparation of these resins was performed in two forms, one directly as the extracting agent to the resin and the other to be used in ethyl alcohol. Conditioned resins were introduced in chromatographic columns in separation of groups, light and heavy, using a standard solution of cerium nitrate and standard solution of holmium nitrate groups to represent light and heavy respectively. The characterization technique used to identify the rare earth elements was Spectrometry X-Ray Fluorescence (XRF). The results using the technique of chromatography were satisfactory, obtaining 100% separation of the elements. (author)

  5. The application of extraction chromatography to the determination of radionuclides in biological and environmental samples

    International Nuclear Information System (INIS)

    Testa, C.; Delle Site, A.

    1976-01-01

    The paper describe the application of extraction chromatography to the determination of several alpha and beta emitters in biological and environmental samples. Both column extraction chromatography and batch extraction process have been used to isolate the radionuclides from the samples. The effect of several parameters (extractant concentration, support granulometry, stirring time, temperature, presence of a complexing agent) on the extraction and elution has been examined. The application of redox extraction chromatography is also described. A very simple and rapid determination of the activity retained on the column can be obtained by transferring the slurry to a counting vial and by adding the scintillation liquid for a direct detection of the α or β emission. The counting efficiencies obtained with this technique are compared with those obtained with ion exchange resins. The organic polymers used for the extraction chromatography give about 100% counting efficiency. The conventional ion exchange resin cannot be used to this purpose because of their strong light absorption. (T.G.)

  6. Simple determination of L-hydroxyproline in idiopathic pulmonary fibrosis lung tissues of rats using non-extractive high-performance liquid chromatography coupled with fluorescence detection after pre-column derivatization with novel synthetic 9-acetylimidazol-carbazole.

    Science.gov (United States)

    Ren, Yan; Zhao, Juanjuan; Shi, Yanan; Chen, Caiyun; Chen, Xiangming; Lv, Changjun

    2017-08-05

    L-Hydroxyproline (L-Hyp) is an important biomarker for idiopathic pulmonary fibrosis (IPF). The quantitative methods based on high-performance liquid chromatography coupled with fluorescence detection after pre-column derivatization typically requires complicated derivatization conditions and obtains unstable derivatives. Here, a novel derivatization reagent, 9-acetylimidazol-carbazole, was synthesized for the first time to efficiently and rapidly label the amino groups of L-Hyp. The high-performance liquid chromatography method with pre-column derivatization was performed on an Agilent ZORBAX SB-C 18 column (4.6×250mm, 5μm). The product was measured using fluorescence detection at excitation and emission wavelengths of 232 and 370nm, respectively. The method was validated in specificity, linearity, limit of detection (66.7 fmol), limit of quantification (333.3fmol), intra-day precision (0.75%), inter-day precision (3.82%), stability (3.15%), and recovery (90.7-109.4%). The validated method was successfully applied to the determination of L-Hyp in the lung tissues of healthy and IPF rats. The results showed that the concentration of L-Hyp (3.64mg/g) in the IPF model was significantly higher than the concentration (2.33mg/g) in the healthy control group with P<0.01. This is a new method for the determination of L-Hyp and can be used for other amino acid-related studies in the future. Copyright © 2017. Published by Elsevier B.V.

  7. Blind column selection protocol for two-dimensional high performance liquid chromatography.

    Science.gov (United States)

    Burns, Niki K; Andrighetto, Luke M; Conlan, Xavier A; Purcell, Stuart D; Barnett, Neil W; Denning, Jacquie; Francis, Paul S; Stevenson, Paul G

    2016-07-01

    The selection of two orthogonal columns for two-dimensional high performance liquid chromatography (LC×LC) separation of natural product extracts can be a labour intensive and time consuming process and in many cases is an entirely trial-and-error approach. This paper introduces a blind optimisation method for column selection of a black box of constituent components. A data processing pipeline, created in the open source application OpenMS®, was developed to map the components within the mixture of equal mass across a library of HPLC columns; LC×LC separation space utilisation was compared by measuring the fractional surface coverage, fcoverage. It was found that for a test mixture from an opium poppy (Papaver somniferum) extract, the combination of diphenyl and C18 stationary phases provided a predicted fcoverage of 0.48 and was matched with an actual usage of 0.43. OpenMS®, in conjunction with algorithms designed in house, have allowed for a significantly quicker selection of two orthogonal columns, which have been optimised for a LC×LC separation of crude extractions of plant material. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. On-column reduction of catecholamine quinones in stainless steel columns during liquid chromatography.

    Science.gov (United States)

    Xu, R; Huang, X; Kramer, K J; Hawley, M D

    1995-10-10

    The chromatographic behavior of quinones derived from the oxidation of dopamine and N-acetyldopamine has been studied using liquid chromatography (LC) with both a diode array detector and an electrochemical detector that has parallel dual working electrodes. When stainless steel columns are used, an anodic peak for the oxidation of the catecholamine is observed at the same retention time as a cathodic peak for the reduction of the catecholamine quinone. In addition, the anodic peak exhibits a tail that extends to a second anodic peak for the catecholamine. The latter peak occurs at the normal retention time of the catecholamine. The origin of this phenomenon has been studied and metallic iron in the stainless steel components of the LC system has been found to reduce the quinones to their corresponding catecholamines. The simultaneous appearance of a cathodic peak for the reduction of catecholamine quinone and an anodic peak for the oxidation of the corresponding catecholamine occurs when metallic iron in the exit frit reduces some of the quinones as the latter exits the column. This phenomenon is designated as the "concurrent anodic-cathodic response." It is also observed for quinones of of 3,4-dihydroxybenzoic acid and probably occurs with o- or p-quinones of other dihydroxyphenyl compounds. The use of nonferrous components in LC systems is recommended to eliminate possible on-column reduction of quinones.

  9. Study of Cs recovery by extraction chromatography (2)

    International Nuclear Information System (INIS)

    Hoshi, Harutaka; Zhang, Anyun; Uchida, Hiromi; Kuraoka, Etsushu

    2005-02-01

    In order to apply CalixR14 extractant to extraction chromatography for Cs separation, basic characteristics of CalixR14 adsorbent were studied. CalixR14 impregnated resin and CalixR14 + TBP impregnated resin were prepared. CalixR14 extractant showed no adsorption for Cs by liquid-liquid extraction and CalixR14 impregnated resin also showed no adsorption for Cs. Therefore, it is concluded that CalixR14 itself has no affinity for Cs. On the other hand, Cs was adsorbed onto CalixR14-TBP impregnated resin from a concentrated nitric acid solution. The distribution coefficients of Cs were more than 10 cm 3 /g from 2 to 6 M nitric acid. While Rb showed week adsorption, Na, K, Sr and La showed no adsorption and separation factor was over 100. A slight amount of CalixR14 and TBP was leaked from impregnated resin into the aqueous phase. Separation from simulated liquid waste was carried out by using a column packed with CalixR14-TBP adsorbent. Na, K, Sr and La were not adsorbed onto the column, however, Cs and Rb were adsorbed onto the column. Cs and Rb were eluted from the column by water. Cs and Rb were quantitatively recovered. (author)

  10. Extraction chromatography of lanthanides, ch. 8

    International Nuclear Information System (INIS)

    Siekierski, S.; Fidelis, I.

    1975-01-01

    The extraction of lanthanides by chelate formation with acidic organophosphorous extractants, by solvation of salts, and in the form of ion pairs is reviewed. The double-double effect and its significance for the lanthanide as well as the actinide separation is discussed. A short survey of the existing data on the enthalpies of lanthanide extraction and on the influence of temperature on their separation factor is given. The resolution ability of columns used for the separation of lanthanides is briefly surveyed

  11. Schinus terebinthifolius countercurrent chromatography (Part III): Method transfer from small countercurrent chromatography column to preparative centrifugal partition chromatography ones as a part of method development.

    Science.gov (United States)

    das Neves Costa, Fernanda; Hubert, Jane; Borie, Nicolas; Kotland, Alexis; Hewitson, Peter; Ignatova, Svetlana; Renault, Jean-Hugues

    2017-03-03

    Countercurrent chromatography (CCC) and centrifugal partition chromatography (CPC) are support free liquid-liquid chromatography techniques sharing the same basic principles and features. Method transfer has previously been demonstrated for both techniques but never from one to another. This study aimed to show such a feasibility using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. Heptane - ethyl acetate - methanol -water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds. The optimized separation methodology previously described in Part I and II, was scaled up from an analytical hydrodynamic CCC column (17.4mL) to preparative hydrostatic CPC instruments (250mL and 303mL) as a part of method development. Flow-rate and sample loading were further optimized on CPC. Mobile phase linear velocity is suggested as a transfer invariant parameter if the CPC column contains sufficient number of partition cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Electronic Nose using Gas Chromatography Column and Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Hari Agus Sujono

    2011-08-01

    Full Text Available The conventional electronic nose usually consists of an array of dissimilar chemical sensors such as quartz crystal microbalance (QCM combined with pattern recognition algorithm such as Neural network. Because of parallel processing, the system needs a huge number of sensors and circuits which may emerge complexity and inter-channel crosstalk problems. In this research, a new type of odor identification which combines between gas chromatography (GC and electronic nose methods has been developed. The system consists of a GC column and a 10-MHz quartz crystal microbalance sensor producing a unique pattern for an odor in time domain. This method offers advantages of substantially reduced size, interferences and power consumption in comparison to existing odor identification system. Several odors of organic compounds were introduced to evaluate the selectivity of the system. Principle component analysis method was used to visualize the classification of each odor in two-dimensional space. This system could resolve common organic solvents, including molecules of different classes (aromatic from alcohols as well as those within a particular class (methanol from ethanol and also fuels (premium from pertamax. The neural network can be taught to recognize the odors tested in the experiment with identification rate of 85 %. It is therefore the system may take the place of human nose, especially for poisonous odor evaluations.

  13. Column, particularly extraction column, for fission and/or breeder materials

    International Nuclear Information System (INIS)

    Vietzke, H.; Pirk, H.

    1980-01-01

    An absorber rod with a B 4 C insert is situated in the long extraction column for a uranyl nitrate solution or a plutonium nitrate solution. The geometrical dimensions are designed for a high throughput with little corrosion. (DG) [de

  14. Separation of alkali metals by extraction chromatography using polyethers

    International Nuclear Information System (INIS)

    Smulek, W.; Lada, W.

    1977-01-01

    Separation of alkali metals by means of acyclic polyether 1,13 bis(8-chinolinyl)1, 4, 7, 10, 13 pentaoxatridecane (CPOD) and cyclic polyether dibenzo-18-crown-6 (DBC) using extraction chromatography is described. Solutions of NaSCN were used as eluting agents. The separation ability of the polyether columns strongly depends on pH and temperature. The following radioisotopes were used in the experiments: Na-22, K-42, Rb-86 and Cs-137. The radionuclide purity of the tracers was examined by γ-ray spectrometry using a Ge(Li) detector and a multichannel γ-ray spectrometer. (T.I.)

  15. Radioanalytical determination of plutonium and americium using ion exchange and extraction chromatography technique in urine

    International Nuclear Information System (INIS)

    Santhanakrishnan, V.; Sreedevi, K.R.; Rajaram, S.; Ravi, P.M.

    2011-01-01

    The use of anion exchange chromatography for the separation of Pu and extraction chromatography technique for the separation of Am from urine samples was studied. In the earlier method, Pu separation was carried out by anion exchange chromatography followed by Am separation by cation exchange chromatography. The chemical recovery of Am obtained by cation exchange separation method was inconsistent and low in the range 30-70%. In this study, the average Pu recovery obtained using anion exchange chromatography was 89.2 with standard deviation of 10.4 and the average Am recovery obtained using extraction chromatography with TRU resin was 77.4 with standard deviation of 14.8. Moreover, Am separation could be completed within three hours using the TRU column compared to two days that were required for the cation exchange chromatography. (author)

  16. Mechanized sephadex LH-20 multiple column chromatography as a prerequisite to automated multi-steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Sippell, W.G.; Bidlingmaier, F.; Knorr, D.

    1977-01-01

    In order to establish a procedure for the simultaneous determination of all major corticosteroid hormones and their immediate biological precursors in the same plasma sample, two different mechanized methods for the simultaneous isolation of aldosterone (A), corticosterone (B), 11-deoxycorticosterone (DOC), progesterone (P), 17-hydroxyprogesterone (17-OHP), 11-deoxycorticol (S), cortisol (F), and cortisone (E) from the methylene chloride extracts of 0.1 to 2.0 ml plasma samples have been developed. In both methods, eluate fractions of each of the isolated steroids are automatically pooled and collected from all parallel columns by one programmable linear fraction collector. Due to the high reproducibility of the elution patterns both between different parallel columns and between 30 to 40 consecutive elutions, mean recoveries of tritiated steroids including extraction are 60 to 84% after a single elution and still over 50% after an additional chromatography on 40cm LH-20 colums, with coefficients of variation below 15%. Thus, the eight steroids can be completely isolated from each of ten plasma extracts within 3 to 4 hours, yielding 80 samples readily prepared for subsequent quantitation by radioimmunoassay. (orig./AJ) [de

  17. Reversed phase column extraction studies to recovery of uranium using a modified perlite

    International Nuclear Information System (INIS)

    Akcay, H.

    2006-01-01

    Reversed phase column (RPC) extraction chromatography is an useful technique and has been carried out successfully to the separation of various metals and organic compounds. Its application has received considerable attention because it combines the selectivity of LLE with the advantage of chromatography. The efficiency of the separation by RPC depends on both the chemical and physical properties of the solid support and the stationary phase. This work describes the preparation of an improved adsorbent from natural perlite and its properties to uptake of uranyl ion. Perlite is a volcanic glassy rock produced in commercially workable quantities from mines of Aegean region of Turkey and contains 70-75% CO 2 .The CO 2 was converted to soluble silicates with NaOH modification then its acidification to form hydrogen which turned into xerogels upon drying. Fundamental parameters (particle size, specific surface area, pore size and volume, surface hydroxyl group density) were determined for modified perlite and it was silanized then loaded with 20% (w/w) TBP before being used as reversed phase column chromatography solid support. Finally the sorption of UO 2 + 2 from aqueous solutions by the modified perlite was investigated using Batch techniques. The use of TBP-loaded perlite as a reversed phase column (RPC) extraction chromatography support seems to be useful to uptake of UO 2 + 2 from aqueous solutions and to separate from various cations

  18. Comparison of column chromatographic and precipitation methods for the purification of a macrocyclic polyether extractant

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, M.L.; Felinto, C.; Rhoads, S.; Clapper, M.; Finch, J.W.; Hay, B.P.

    1999-11-01

    Column chromatography on aminopropyl-derivatized silica and precipitation of a complex with perchloric acid have been evaluated as methods for the purification of di-tert-butylcyclohexano-18-crown-6 (DtBuCH18C6), a compound frequently employed for the selective extraction of strontium from acidic nitrate media. Both methods are shown to provide a simple and effective means of eliminating inactive sample components (i.e., impurities or stereoisomers incapable of extracting strontium) from the crown ether and enriching the material in 4(z),4{prime}(z) cis-syn-cis DtBuCH18C6, a stereoisomer capable of highly efficient strontium extraction.

  19. Comparison of column chromatographic and precipitation methods for the purification of a macrocyclic polyether extractant

    International Nuclear Information System (INIS)

    Dietz, M.L.; Felinto, C.; Rhoads, S.; Clapper, M.; Finch, J.W.; Hay, B.P.

    1999-01-01

    Column chromatography on aminopropyl-derivatized silica and precipitation of a complex with perchloric acid have been evaluated as methods for the purification of di-tert-butylcyclohexano-18-crown-6 (DtBuCH18C6), a compound frequently employed for the selective extraction of strontium from acidic nitrate media. Both methods are shown to provide a simple and effective means of eliminating inactive sample components (i.e., impurities or stereoisomers incapable of extracting strontium) from the crown ether and enriching the material in 4(z),4 prime(z) cis-syn-cis DtBuCH18C6, a stereoisomer capable of highly efficient strontium extraction

  20. The design of a new concept chromatography column.

    Science.gov (United States)

    Camenzuli, Michelle; Ritchie, Harald J; Ladine, James R; Shalliker, R Andrew

    2011-12-21

    Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.

  1. Multi-column step-gradient chromatography system for automated ion exchange separations

    International Nuclear Information System (INIS)

    Rucker, T.L.

    1985-01-01

    A multi-column step-gradient chromatography system has been designed to perform automated sequential separations of radionuclides by ion exchange chromatography. The system consists of a digital programmer with automatic stream selection valve, two peristaltic pumps, ten columns, and a fraction collector. The automation allows complicated separations of radionuclides to be made with minimal analyst attention and allows for increased productivity and reduced cost of analyses. Results are reported for test separations on mixtures of radionuclides by the system

  2. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  3. Hydrodynamic chromatography of polystyrene microparticles in micropillar array columns

    NARCIS (Netherlands)

    Op de Beeck, Jeff; de Malsche, Wim; Vangelooven, Joris; Gardeniers, Johannes G.E.; Desmet, Gert

    2010-01-01

    We report on the possibility to perform HDC in micropillar array columns and the potential advantages of such a system. The HDC performance of a pillar array column with pillar diameter = 5 μm and an interpillar distance of 2.5 μm has been characterized using both a low MW tracer (FITC) and

  4. Characterization of retentivity of reversed phase liquid chromatography columns.

    Science.gov (United States)

    Ying, P T; Dorsey, J G

    1991-03-01

    There are dozens of commercially available reversed phase columns, most marketed as C-8 or C-18 materials, but with no useful way of classifying their retentivity. A useful way of ranking these columns in terms of column "strength" or retentivity is presented. The method utilizes a value for ln k'(w), the estimated retention of a solute from a mobile phase of 100% water, and the slope of the plot of ln k' vsE(T)(30), the solvent polarity. The method is validated with 26 solutes varying in ln k'(w) from about 2 to over 20, on 14 different reversed phase columns. In agreement with previous work, it is found that the phase volume ratio of the column is the most important parameter in determining retentivity. It is strongly suggested that manufacturers adopt a uniform method of calculating this value and that it be made available in advertising, rather than the uninterpretable "% carbon".

  5. Improved Reversed Phase Chromatography of Hydrophilic Peptides from Spatial and Temporal Changes in Column Temperature

    DEFF Research Database (Denmark)

    Young, Clifford; Podtelejnikov, Alexandre V; Nielsen, Michael Lund

    2017-01-01

    implementation requires additional equipment and method optimization. An apparatus that allows temperature manipulation in three areas of a two-column setup was evaluated for improvements in chromatography. Using commercially available standards, we demonstrate that a low column temperature (0 °C) during sample...

  6. Separation of Be and Al for AMS using single-step column chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Binnie, Steven A., E-mail: sbinnie@uni-koeln.de [Institute for Geology und Mineralogy, University of Cologne, 4-6 Greinstrasse, Cologne D-50939 (Germany); Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz [Institute for Geology und Mineralogy, University of Cologne, 4-6 Greinstrasse, Cologne D-50939 (Germany); Heinze, Stefan; Dewald, Alfred [University of Cologne, Institut für Kernphysik, Zülpicher Str. 77, Cologne D-50937 (Germany)

    2015-10-15

    With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC–Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. {sup 10}Be and {sup 26}Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC–Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.

  7. Separation of Be and Al for AMS using single-step column chromatography

    Science.gov (United States)

    Binnie, Steven A.; Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred

    2015-10-01

    With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC-Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. 10Be and 26Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC-Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.

  8. An efficient hydrophilic interaction liquid chromatography separation of 7 phospholipid classes based on a diol column

    NARCIS (Netherlands)

    Zhu, C.; Dane, A.; Spijksma, G.; Wang, M.; Greef, J. van der; Luo, G.; Hankemeier, T.; Vreeken, R.J.

    2012-01-01

    A hydrophilic interaction liquid chromatography (HILIC) - ion trap mass spectrometry method was developed for separation of a wide range of phospholipids. A diol column which is often used with normal phase chromatography was adapted to separate different phospholipid classes in HILIC mode using a

  9. Extraction Chromatography for Am and Cm Recovery in Engineering Scale

    International Nuclear Information System (INIS)

    Koma, Y.; Watanabe, S.; Sano, Y.; Asakura, T.; Morita, Y.

    2008-01-01

    The Japan Atomic Energy Agency (JAEA) has been developing the extraction chromatography for Am and Cm (An(III)) recovery from HLLW aiming at an engineering scale application. For process development, we started to assess the characteristics of adsorbents with some extractants by laboratory scale experiments. The experimental results with HDEHP/SiO 2 -P adsorbent suggested that An(III) is separated from other fission products by adjusting the pH of a feed solution and/or an eluent containing DTPA to be an appropriate value. The durability of CMPO/SiO 2 -P and HDEHP/SiO 2 -P adsorbents for gamma-ray irradiation were estimated to be 1 and 0.5 MGy, respectively. In the system development, system experiments for fluid flow, safety and durability using engineering scale column as well as studies on remote control/maintenance are now under progress. (authors)

  10. Tritium extraction from Pb-17Li by bubble columns

    International Nuclear Information System (INIS)

    Malara, C.

    1995-01-01

    Tritium extraction from the Pb-17Li liquid breeder of a fusion reactor can be efficiently carried out by bubble columns. To this aim, a mathematical model describing the complex fluid-dynamics of a bubble extractor is here presented. The model equations are made dimensionless and, together with the proper boundary conditions, numerically solved by the orthogonal collocation technique. Moreover, in order to better understand the role played by the different parameters in determining the performance of a bubble column, a closed solution of the model is obtained by introducing suitable hypotheses. A parametric analysis of the extraction efficiency of a bubble column as a function of the process parameters is carried out and, on this basis, the design of a tritium extraction system from the Pb-17Li breeder of a DEMO-type fusion reactor is proposed. 17 refs., 3 figs., 2 tabs

  11. Using solvent extraction to process nitrate anion exchange column effluents

    International Nuclear Information System (INIS)

    Yarbro, S.L.

    1987-10-01

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO), a new organophosphorous extractant, and a new centrifugal mixer-settler both recently developed at Argonne were evaluated for their potential use in the recovery of actinides from nitrate anion exchange column effluents. The performance of the extractant was evaluated by measuring the extraction coefficient values as a function of acid and salt concentration. Additional performance parameters include extraction coefficient behavior as a function of the total metal concentration in the organic phase, and comparison of different stripping and organic scrubbing techniques. A simulated effluent stream was used to evaluate the performance of the centrifugal mixer-settlers by comparing experimental and calculated interstage concentration profiles. Both the CMPO extractant and the centrifugal mixer-settlers have potential for processing nitrate column effluents, particularly if the stripping behavior can be improved. Details of the proposed process are presented in the flowsheet and contactor design analyses

  12. Using solvent extraction to process nitrate anion exchange column effluents

    Energy Technology Data Exchange (ETDEWEB)

    Yarbro, S.L.

    1987-10-01

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO), a new organophosphorous extractant, and a new centrifugal mixer-settler both recently developed at Argonne were evaluated for their potential use in the recovery of actinides from nitrate anion exchange column effluents. The performance of the extractant was evaluated by measuring the extraction coefficient values as a function of acid and salt concentration. Additional performance parameters include extraction coefficient behavior as a function of the total metal concentration in the organic phase, and comparison of different stripping and organic scrubbing techniques. A simulated effluent stream was used to evaluate the performance of the centrifugal mixer-settlers by comparing experimental and calculated interstage concentration profiles. Both the CMPO extractant and the centrifugal mixer-settlers have potential for processing nitrate column effluents, particularly if the stripping behavior can be improved. Details of the proposed process are presented in the flowsheet and contactor design analyses.

  13. Method of analysis and quality-assurance practices for determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry at the U.S. Geological Survey California District Organic Chemistry Laboratory, 1996-99

    Science.gov (United States)

    Crepeau, Kathryn L.; Baker, Lucian M.; Kuivila, Kathryn

    2000-01-01

    A method of analysis and quality-assurance practices were developed to study the fate and transport of pesticides in the San Francisco Bay-Estuary by the U.S. Geological Survey. Water samples were filtered to remove suspended-particulate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide and the pesticides were eluted with three cartridge volumes of hexane:diethyl ether (1:1) solution. The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for pesticides ranged from 0.002 to 0.025 microgram per liter for 1-liter samples. Recoveries ranged from 44 to 140 percent for 25 pesticides in samples of organic-free reagent water and Sacramento-San Joaquin Delta and Suisun Bay water fortified at 0.05 and 0.50 microgram per liter. The estimated holding time for pesticides after extraction on C-8 solid-phase extraction cartridges ranged from 10 to 257 days.

  14. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  15. Fingerprinting of traditional Chinese medicines on the C18-Diol mixed-mode column in online or offline two-dimensional liquid chromatography on the single column modes.

    Science.gov (United States)

    Wang, Qing; Tong, Ling; Yao, Lin; Zhang, Peng; Xu, Li

    2016-06-05

    In the present study, a mixed-mode stationary phase, C18-Diol, was applied for fingerprint analysis of traditional Chinese medicines. Hydrophobic, hydrogen bonding and electrostatic interactions were demonstrated to contribute the retention separately or jointly, which endowed the C18-Diol stationary phase with distinct selectivity compared to the bare C18 one. The separation of total alkaloids extracted from Fritillaria hupehensis was compared on the C18-Diol and conventional C18 column with the greater resolving power and better symmetry responses on the former one. Besides, a novel two-dimensional liquid chromatography on the single column (2D-LC-1C) was realized on C18-Diol with the offline mode for the alcohol extract of Fritillaria hupehensis and online mode for Ligusticum chuanxiong Hort. The early co-eluted extracted components with great polarity on the first dimension were reinjected on the same column and well separated on the second dimension. The results exhibited that the two complementary RPLC and HILIC modes on C18-Diol stationary phase enhanced the separation capacity and revealed more abundant chemical information of the sample, which was a powerful tool in analyzing complex herbal medicines. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Determination of betaine, l-carnitine, and choline in human urine using a self-packed column and column-switching ion chromatography with nonsuppressed conductivity detection.

    Science.gov (United States)

    Wei, Dan; Liu, Junwei; Guo, Ming; Zhu, Yan

    2017-11-01

    A simple method for the determination of betaine, l-carnitine, and choline in human urine was developed based on column-switching ion chromatography coupled with nonsuppressed conductivity detection by using a self-packed column. A pretreatment column (50 mm × 4.6 mm, id) packed with poly(glycidyl methacrylate-divinylbenzene) microspheres was used for the extraction and cleanup of analytes. Chromatographic separation was achieved within 10 min on a cationic exchange column (150 mm × 4.6 mm, id) using maleic anhydride modified poly(glycidyl methacrylate-divinylbenzene) as the particles for packing. The detection was performed by ion chromatography with nonsuppressed conductivity detection. Parameters including column-switching time, eluent type, flow rates of eluent, and interfering effects were optimized. Linearity (r 2 ≥ 0.99) was obtained for the concentration range of 0.50-100, 0.75-100, and 0.25-100 μg/mL for betaine, l-carnitine, and choline, respectively. Detection limits were 0.12, 0.20, and 0.05 μg/mL for betaine, l-carnitine, and choline, respectively. The intra- and interday accuracy and precision for all quality controls were within ±10.11%. Satisfactory recovery was observed between 92.5 and 105.0%. The validated method was successfully applied for the determination of betaine, l-carnitine, and choline in urine samples from healthy people. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Robust naphthyl methacrylate monolithic column for high performance liquid chromatography of a wide range of solutes.

    Science.gov (United States)

    Jonnada, Murthy; El Rassi, Ziad

    2015-08-28

    An organic monolithic column based on the co-polymerization of 2-naphthyl methacrylate (NAPM) as the functional monomer and trimethylolpropane trimethacrylate (TRIM) as the crosslinker was introduced for high performance reversed-phase liquid chromatography (RPC). The co-polymerization was performed in situ in a stainless steel column of 4.6mm i.d. in the presence of a ternary porogen consisting of 1-dodecanol and cyclohexanol. This monolithic column (referred to as naphthyl methacrylate monolithic column or NMM column) showed high mechanical stability at relatively high mobile phase flow velocity indicating that the column has excellent hydrodynamic characteristics. To characterize the NMM column, different probe molecules including alkyl benzenes, and aniline, benzene, toluene and phenol derivatives were chromatographed on the column and the results in terms of k, selectivity and plate counts were compared to those obtained on an octadecyl silica (ODS) column in order to assess the presence of π-π and hydrophobic interactions on the NMM column under otherwise the same elution conditions. The NMM column offered additional π-π interactions with aromatic molecules in addition to hydrophobic interactions under RPC elution conditions. Run-to-run and column-to-column reproducibility of solute k values were evaluated, and percent relative standard deviation of column using shallow (30min at 1.0mL/min), steep (10min at 1.0mL/min) and ultra steep (1min at 3.0mL/min) linear gradient elution at increasing ACN concentration in the mobile phase using a 10cm×4.6mm i.d. column in case of shallow and steep linear gradients and a 3cm×4.6mm i.d. column for ultra steep linear gradient. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Characterization of the efficiency of microbore liquid chromatography columns by van Deemter and kinetic plot analysis.

    Science.gov (United States)

    Hetzel, Terence; Loeker, Denise; Teutenberg, Thorsten; Schmidt, Torsten C

    2016-10-01

    The efficiency of miniaturized liquid chromatography columns with inner diameters between 200 and 300 μm has been investigated using a dedicated micro-liquid chromatography system. Fully porous, core-shell and monolithic commercially available stationary phases were compared applying van Deemter and kinetic plot analysis. The sub-2 μm fully porous as well as the 2.7 μm core-shell particle packed columns showed superior efficiency and similar values for the minimum reduced plate heights (2.56-2.69) before correction for extra-column contribution compared to normal-bore columns. Moreover, the influence of extra-column contribution was investigated to demonstrate the difference between apparent and intrinsic efficiency by replacing the column by a zero dead volume union to determine the band spreading caused by the system. It was demonstrated that 72% of the intrinsic efficiency could be reached. The results of the kinetic plot analysis indicate the superior performance of the sub-2 μm fully porous particle packed column for ultra-fast liquid chromatography. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Effects of salts on protein-surface interactions: applications for column chromatography.

    Science.gov (United States)

    Tsumoto, Kouhei; Ejima, Daisuke; Senczuk, Anna M; Kita, Yoshiko; Arakawa, Tsutomu

    2007-07-01

    Development of protein pharmaceuticals depends on the availability of high quality proteins. Various column chromatographies are used to purify proteins and characterize the purity and properties of the proteins. Most column chromatographies require salts, whether inorganic or organic, for binding, elution or simply better recovery and resolution. The salts modulate affinity of the proteins for particular columns and nonspecific protein-protein or protein-surface interactions, depending on the type and concentration of the salts, in both specific and nonspecific manners. Salts also affect the binding capacity of the column, which determines the size of the column to be used. Binding capacity, whether equilibrium or dynamic (under an approximation of a slow flow rate), depends on the binding constant, protein concentration and the number of the binding site on the column as well as nonspecific binding. This review attempts to summarize the mechanism of the salt effects on binding affinity and capacity for various column chromatographies and on nonspecific protein-protein or protein-surface interactions. Understanding such salt effects should also be useful in preventing nonspecific protein binding to various containers. Copyright 2007 Wiley-Liss, Inc.

  20. Miniaturized protein separation using a liquid chromatography column on a flexible substrate

    International Nuclear Information System (INIS)

    Yang Yongmo; Chae, Junseok

    2008-01-01

    We report a prototype protein separator that successfully miniaturizes existing technology for potential use in biocompatible health monitoring implants. The prototype is a liquid chromatography (LC) column (LC mini-column) fabricated on an inexpensive, flexible, biocompatible polydimethylsiloxane (PDMS) enclosure. The LC mini-column separates a mixture of proteins using size exclusion chromatography (SEC) with polydivinylbenzene beads (5–20 µm in diameter with 10 nm pore size). The LC mini-column is smaller than any commercially available LC column by a factor of ∼11 000 and successfully separates denatured and native protein mixtures at ∼71 psi of the applied fluidic pressure. Separated proteins are analyzed using NuPAGE-gel electrophoresis, high-performance liquid chromatography (HPLC) and an automated electrophoresis system. Quantitative HPLC results demonstrate successful separation based on intensity change: within 12 min, the intensity between large and small protein peaks changed by a factor of ∼20. In further evaluation using the automated electrophoresis system, the plate height of the LC mini-column is between 36 µm and 100 µm. The prototype LC mini-column shows the potential for real-time health monitoring in applications that require inexpensive, flexible implant technology that can function effectively under non-laboratory conditions

  1. [Preparation and applications of a supported liquid-liquid extraction column with a composite diatomite material].

    Science.gov (United States)

    Bao, Jianmin; Ma, Zhishuang; Sun, Ying; Wang, Yongzun; Li, Youxin

    2012-08-01

    A rapid and special supported liquid-liquid extraction (SLE) column was developed with a composite diatomite material. The SLE column was evaluated by high performance liquid chromatography (HPLC) with acidic, neutral and alkaline compounds dissolved in water. Furthermore, some real complex samples were also analyzed by HPLC with the SLE method. The recoveries of benzoic acid (acidic), p-nitroaniline (alkaline) and 4-hydroxy-benzoic methyl ester (neutral) treated by the SLE column were 90.6%, 98.1% and 97.7%. However, the recoveries of the three compounds treated by traditional liquid-liquid extraction (LLE) method were 71.9%, 81.9% and 83.9%. The results showed that the SLE technique had higher recoveries than the traditional LLE method. The spiked recoveries of the complex samples, such as benzoic acid in Sprite and dexamethasone acetate, chlorphenamine maleate, indomethacin in bovine serum, were between 80% and 110% and the relative standard deviations (RSDs) were less than 15%. For biological specimen, the results could be accepted. Meantime, many disadvantages associated with traditional LLE method, such as emulsion formation, didn't occur using SLE column. The SLE column technique is a good sample preparation method with many advantages, such as rapid, simple, robust, easily automated, high recovery and high-throughput, which would be widely used in the future.

  2. Hydrodynamic chromatography of polystyrene microparticles in micropillar array columns.

    Science.gov (United States)

    Op de Beeck, Jeff; De Malsche, Wim; Vangelooven, Joris; Gardeniers, Han; Desmet, Gert

    2010-09-24

    We report on the possibility to perform HDC in micropillar array columns and the potential advantages of such a system. The HDC performance of a pillar array column with pillar diameter = 5 microm and an interpillar distance of 2.5 microm has been characterized using both a low MW tracer (FITC) and differently sized polystyrene bead samples (100, 200 and 500 nm). The reduced plate height curves that were obtained for the different investigated markers all overlapped very well, and attained a minimum value of about h(min)=0.3 (reduction based on the pillar diameter), corresponding to 1.6 microm in absolute value and giving good prospects for high efficiency separations. The obtained reduced retention time values were in fair agreement with that predicted by the Di Marzio and Guttman model for a flow between flat plates, using the minimal interpillar distance as characteristic interplate distance. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Adiabatic packed column supercritical fluid chromatography using a dual-zone still-air column heater.

    Science.gov (United States)

    Helmueller, Shawn C; Poe, Donald P; Kaczmarski, Krzysztof

    2018-02-02

    An approach to conducting SFC separations under pseudo-adiabatic condition utilizing a dual-zone column heater is described. The heater allows for efficient separations at low pressures above the critical temperature by imposing a temperature profile along the column wall that closely matches that for isenthalpic expansion of the fluid inside the column. As a result, the efficiency loss associated with the formation of radial temperature gradients in this difficult region can be largely avoided in packed analytical scale columns. For elution of n-octadecylbenzene at 60 °C with 5% methanol modifier and a flow rate of 3 mL/min, a 250 × 4.6-mm column packed with 5-micron Kinetex C18 particles began to lose efficiency (8% decrease in the number of theoretical plates) at outlet pressures below 142 bar in a traditional forced air oven. The corresponding outlet pressure for onset of excess efficiency loss was decreased to 121 bar when the column was operated in a commercial HPLC column heater, and to 104 bar in the new dual-zone heater operated in adiabatic mode, with corresponding increases in the retention factor for n-octadecylbenzene from 2.9 to 6.8 and 14, respectively. This approach allows for increased retention and efficient separations of otherwise weakly retained analytes. Applications are described for rapid SFC separation of an alkylbenzene mixture using a pressure ramp, and isobaric separation of a cannabinoid mixture. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Determination of Formaldehyde in Frozen Fish with Formaldehyde Dehydrogenase Using a Flow Injection System with an Incorporated Gel-filtration Chromatography Column

    DEFF Research Database (Denmark)

    Bechmann, Iben Ellegaard

    1996-01-01

    in a FIA system. The FIA system is furnished with a gel-filtration chromatography column for on-line removal of the proteins from the extract before the enzymatic analysis is performed. Compared with the standard methods for determination of formaldehyde in fish products the present method is much faster...

  5. Environmental Conditions Influencing Sorption of Inorganic Anions to Multiwalled Carbon Nanotubes Studied by Column Chromatography.

    Science.gov (United States)

    Metzelder, Florian; Schmidt, Torsten C

    2017-05-02

    Sorption to carbon-based nanomaterials is typically studied in batch experiments. An alternative method offering advantages to study sorption is column chromatography. Sorbent packed columns are used and sorption data are determined by relating sorbate retention to that of a nonretarded tracer. We have now for the first time applied this technique to study the influence of environmental conditions on sorption of inorganic anions (bromide, nitrite, nitrate, and iodide) to multiwalled carbon nanotubes. Deuterium oxide was used as nonretarded tracer. Sorption isotherms were best described by the Freundlich model. Sorption increased in the order bromide 4.5 the surface charge was negative, but sorption was still detectable at pH 6 and 9. Consequently, other forces than electrostatic attraction contributed to sorption. These forces may include H-bonding as indicated by sorption enthalpy determined by variation of column temperature. Overall, column chromatography represents a promising alternative in sorption studies to reveal sorbent properties.

  6. Controlled crosslinking of trimethylolpropane trimethacrylate for preparation of organic monolithic columns for capillary liquid chromatography.

    Science.gov (United States)

    Gama, Mariana R; Aggarwal, Pankaj; Lee, Milton L; Bottoli, Carla B G

    2017-11-01

    Organic monolithic columns based on single crosslinking of trimethylolpropane trimethacrylate (TRIM) monomer were prepared in a single step by living/controlled free-radical polymerization. Full optimization of the preparation, such as using different percentages of TRIM and different amounts of radical promoter as well as various porogen solvents were explored. The resulting monolithic columns were characterized by scanning electronic microscopy and nitrogen sorption for structure morphology studies and surface area measurements, respectively. Using capillary liquid chromatography, 150 μm i.d. columns were applied to separate a mixture of small hydrophobic molecules. The results indicated that column performance is highly sensitive to the type and the amount of porogen solvents used in the polymerization mixture composition. Good resolution factors and methylene selectivity were obtained, indicating the promising potential of this material for capillary liquid chromatography separations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Single-column ion chromatography with determination of hydrazoic acid produced in spent nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Ma Guilan; Tan Shuping

    2006-01-01

    The reaction of hydrazine and its derivative with ammonium metavanadate may produce hydrazoic acid (HN 3 ). A single-column ion chromatography is used for the determination of HN 3 after neutralizing the rest acid in the sample with sodium hydroxide. Chromatography separation of HN 3 is carried out on a 25 cm x 0.46 cm (inside diameter) stainless steel column packed with Vydac IC302 ion Chromatography packing. The eluent is 1 mmol/L o-phthalic acid, and the ion is detected by conductivity detector. The detection limit in the presence chromatography is 5 μg/mL, the linear range is from 5 to 201 μg/mL, the linear correlation coefficient is 0.9994, respectively. The analysis accuracy is 2% for standard sample, and the detection limit is 51 μg/mL for HN 3 in the real sample. (authors)

  8. Super/subcritical fluid chromatography with packed columns: state of the art and applications

    Directory of Open Access Journals (Sweden)

    Carla Grazieli Azevedo da Silva

    2014-07-01

    Full Text Available Separations using supercritical fluid chromatography (SFC with packed columns have been re-discovered and explored in recent years. SFC enables fast and efficient separations and, in some cases, gives better results than high performance liquid chromatography (HPLC. This paper provides an overview of recent advances in SFC separations using packed columns for both achiral and chiral separations. The most important types of stationary phases used in SFC are discussed as well as the most critical parameters involved in the separations and some recent applications.

  9. A hybrid FIA/HPLC system incorporating monolithic column chromatography

    International Nuclear Information System (INIS)

    Adcock, Jacqui L.; Francis, Paul S.; Agg, Kent M.; Marshall, Graham D.; Barnett, Neil W.

    2007-01-01

    We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2'-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection

  10. PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN

    Directory of Open Access Journals (Sweden)

    İ. Metin HASDEMİR

    1999-03-01

    Full Text Available The influence of feed ratios ((LE/LR on the performance of a packed liquid-liquid extraction column, with a diameter of 5.86 cm and a column height of 132 cm was investigated. The column is made of borosilicate glass and packed with 10 x 10 mm glass Raschig rings. In this study, a ternary system composed of water + propionic acid + trichloroethylene was used. The data used to triangular diagram were obtained experimentally. The overall mass transfer coefficients, the numbers of overall mass transfer units, the heights of mass transfer units, the numbers of theoretical stages and height equivalent to a theoretical stage (H. E. T. S. values were calculated and compared with each other.

  11. Purification of antibody against Ara h 2 by a homemade immunoaffinity chromatography column.

    Science.gov (United States)

    Wu, Zhihua; Li, Kun; Zhan, Shaode; Tong, Ping; Li, Xin; Yang, Anshu; Chen, Hongbing

    2017-09-14

    Antibodies are used extensively in numerous applications both in vivo and in vitro. To purify anti-Ara h 2 polyclonal antibody, a homemade immunoaffinity chromatography (IAC) column method was established. The properties of homemade column were compared with those of the mAb affinity protein G (MPG) agarose high flow, a commercially available column successfully used in capturing polyclonal antibodies. During antibody purification from rabbits' antiserum against Ara h 2, the column capacity, recovery, and purification factor were characterized for IAC and MPG. The homemade IAC could separate the corresponding antibody with higher specificity and lower cost but with lower recovery and column capacity than those of MPG. Thus, the homemade IAC is a specific, inexpensive, and suitable method that can be used for various laboratory purifications.

  12. Carrier effect on separation efficiency of the column in reversed-phase partition chromatography

    International Nuclear Information System (INIS)

    Pszonicka, M.; Siekierski, S.

    1972-01-01

    Chromatographic columns were filled with carriers of diatomaceous earth type (Hyflo Super Cell, and Celite 545) of large pores, and two microporous silica gels respectively. These columns were used for the separation of europium and gadolinium by reversed-phase partition chromatography in the system: stationary phase-diethylhexylphosphoric acid (HDEHP) mobile phase-0.4 N nitric acid. In each case the separation of the above mentioned elements was achieved. The plate height that characterizes separation efficiency of the column, decreases with the decrease of particle diameter of the carrier. Best columns were obtained from carriers of large pores (Hyflo Super Cell and Celite 545) for which plate hights below 0.1 mm could be achieved. Columns filled with microporous silica gels showed plate heights of 0.2-0.3 mm. (author)

  13. Investigation of Pinus mugo essential oil oxygenated fraction by combined use of gas chromatography and dry column chromatography.

    Science.gov (United States)

    A, M B; Coran, S A; Giannellini, V; Vincieri, F F; Moneti, G

    1981-09-01

    The oxygenated compounds of Pinus mugo Turra essential oil were investigated by a combination of GC and dry column chromatography (DCC) coordinated by GC data processing. The collected data resulted in a bar graph ("normalized" gas chromatogram) giving the RRT's and relative amounts of 68 components; 38 of them were identified by MS and IR. The described procedure may be used for essential oil analysis in general.

  14. Multi-column chromatography and the use of isotopes in the study of steroid metabolism

    International Nuclear Information System (INIS)

    Sayegh, J.F.; Vestergaard, P.

    1978-01-01

    Multi-column liquid chromatography is demonstrated to be a technique well suited for isotope experiments involving administration of labelled cortisol. It has potential for secretion rate determinations, for dynamic studies of cortisol metabolism and for work with stable isotopes. (author)

  15. Novel approach to determine ghrelin analogs by liquid chromatography with mass spectrometry using a monolithic column

    Czech Academy of Sciences Publication Activity Database

    Zemenová, Jana; Sýkora, D.; Adámková, H.; Maletínská, Lenka; Elbert, Tomáš; Marek, Aleš; Blechová, Miroslava

    2017-01-01

    Roč. 40, č. 5 (2017), s. 1032-1039 ISSN 1615-9306 Institutional support: RVO:61388963 Keywords : enzyme-linked immunosorbent assay * ghrelin * lipopeptides * liquid chromatography mass spectrometry * monolithic columns Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.557, year: 2016

  16. Second dimension column ensemble pressure tuning in comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Junior, Ademario I da Silva; Marriott, Philip J

    2018-02-09

    A pressure tunable (PT) coupled column ensemble has been implemented for the second dimension ( 2 D) separation in comprehensive two dimensional gas chromatography (GC×PTGC). This process requires two columns to be connected by a pressure junction, as a replacement for a single narrow bore, short column in 2 D. Various 2 D 1 and 2 D 2 columns may be selected to provide complementary selectivity (polarity) compared to the 1 D column. The tunable residence time arising from differential pressure drop in each 2 D column results in a tunable fractional contribution of each column in the 2 D separation. A sample mixture comprising different chemical classes, including alkanes and alcohols, is used to identify the feasibility and extent of selectivity tuning possible in GC×PTGC. The column length is also varied due to the imposed challenge of wraparound in the PT coupled column system as pressures are adjusted in the 2 D separation. Different experimental parameters, stationary phase materials and column lengths have been applied to investigate and understand the separation behaviour of the 2 D PT coupled column GC×GC system. Results are discussed considering analyte retention time, peak width, linear velocity and the contribution of each 2 D column. A specific and unexpected example of GC×GC separation was demonstrated where the peak positions of polar and apolar compounds could almost swap their 2 D retention position by application of PT. Kerosene was analysed as an example of complex sample analysis by GC×PTGC system. This process is shown to be a practical approach for altering different stationary phase selectivities in a single 2 D arrangement in GC×GC. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. A monolithically fabricated gas chromatography separation column with an integrated high sensitivity thermal conductivity detector

    International Nuclear Information System (INIS)

    Kaanta, Bradley C; Zhang, Xin; Chen, Hua

    2010-01-01

    The monolithic integration of a high sensitivity detector with a gas chromatography (GC) separation column creates many potential advantages over the discrete components of a traditional chromatography system. In miniaturized high-speed GC systems, component interconnections can cause crucial errors and loss of fidelity during detection and analysis. A monolithically integrated device would eliminate the need to create helium-tight interconnections, which are bulky and labor intensive. Additionally, batch fabrication of integrated devices that no longer require expensive and fragile detectors can decrease the cost of micro GC systems through economies of scale. We present the design, fabrication and operation of a monolithic GC separation column and detector. Our device is able to separate nitrogen, methane and carbon dioxide within 30 s. This method of device integration could be applied to the existing wealth of column geometries and chemistries designed for specialized applications.

  18. Taming axial dispersion in hydrodynamic chromatography columns through wall patterning

    Science.gov (United States)

    Adrover, Alessandra; Cerbelli, Stefano; Giona, Massimiliano

    2018-04-01

    A well-known limitation of hydrodynamic chromatography arises from the synergistic interaction between transverse diffusion and streamwise convection, which enhances axial dispersion through the Taylor-Aris mechanism. We show that a periodic sequence of slip/no-slip conditions at the channel walls (e.g., representing wall indentations hosting stable air pockets) can significantly reduce axial dispersion, thus enhancing separation performance. The theoretical/numerical analysis is based on a generalization of Brenner's macrotransport approach to solute transport, here modified to account for the finite-size of the suspended particles. The most effective dispersion-taming outcome is observed when the alternating sequence of slip/no-slip conditions yields non-vanishing cross-sectional flow components. The combination of these components with the hindering interaction between the channel boundaries and the finite-sized particles gives rise to a non-trivial solution of Brenner's problem on the unit periodic cell, where the cross-sectional particle number density departs from the spatially homogeneous condition. In turn, this effect impacts upon the solution of the so-called b-field defining the large-scale dispersion tensor, with an overall decremental effect on the axial dispersion coefficient and on the Height Equivalent of a Theoretical Plate.

  19. Stage wise modeling of liquid-extraction column (RDC)

    International Nuclear Information System (INIS)

    Bastani, B.

    2004-01-01

    Stage wise forward mixing model considering coalescence and re dispersion of drops was used to predict the performance of Rotating Disk Liquid Extraction Contactors. Experimental data previously obtained in two RDC columns of 7-62 cm diameter, 73.6 cm height and 21.9 cm diameter,150 cm height were used to evaluate the model predications. Drops-side mass transfer coefficients were predicted applying Hand los-baron drop model and onley's model was used to predict velocities. According to the results obtained the followings could be concluded: (1) If the height of coalescence and re dispersion i.e.:h=h p Q p / Q could be estimated, the stage wise forward mixing with coalescence and re dispersion model will predict the column height and efficiency with the acceptable accuracy, (2) The stage wise modeling predictions are highly dependent on the number of stages used when the number of stages is less than 10 and (3) Application of continuous phase mass transfer axial dispersion coefficients (k c and E c ) obtained from the solute concentration profile along the column height will predict the column performance more accurately than the Calder bank and moo-young (for K c ) and Kumar-Heartland (for E c ) correlations

  20. The art and science of forming packed analytical high-performance liquid chromatography columns.

    Science.gov (United States)

    Kirkland, J J; Destefano, J J

    2006-09-08

    Columns of packed particles still are the most popular devices for high-performance liquid chromatography (HPLC) separations because of their great utility, excellent performance and wide variety. However, the forming of packed beds for efficient, stable columns traditionally has been an art where the basics of how to form optimum beds generally was not well understood. The recent development of monolith rods was introduced in part to overcome the difficulty of producing stable beds of packing particles. However, these materials are less versatile than packed particle columns. Technology developments in recent years have produced a better understanding among those skilled in the practice of how to form optimized packed beds, and this has led to widely available, high-quality commercial columns. This presentation discusses the developments that led to the present state of column packing technology. Important steps in the packing of efficient, stable beds are described. The key step of selecting the best solvent for the slurry packing method is emphasized. Factors affecting the mechanical stability of packed columns also are discussed. The early art of packing columns now has evolved into a more scientific approach that allows the packing of good columns with a minimum of effort and time.

  1. Preparative separation and purification of rosmarinic acid from perilla seed meal via combined column chromatography.

    Science.gov (United States)

    Tang, Weizhuo; Sun, Baoshan; Zhao, Yuqing

    2014-02-01

    In this study, the preparative separation and purification of rosmarinic acid (RA) from perilla seed meal (PSM), which is a by-product of edible oil production, was achieved using combined column chromatography over macroporous and polyamide resins. To optimize the RA enrichment process, the performance and separation characteristics of nine selected macroporous resins with different chemical and physical properties were investigated. SP825 resin was the most effective: the content of RA increased from 0.27% in the original extract to 16.58% in the 50% ethanol fraction (a 61.4-fold increase). During further purification treatment on polyamide resin, 90.23% pure RA could be obtained in the 70% ethanol fraction. RA with a higher purity (>95%) could also be easily obtained using one crystallization operation. The proposed method is simple, easily operated, cost-effective, and environmentally friendly and is suitable for both large-scale RA production and waste management. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Study on two phase flow characteristics in annular pulsed extraction column with different ratio of annular width to column diameter

    International Nuclear Information System (INIS)

    Qin Wei; Dai Youyuan; Wang Jiading

    1994-01-01

    Annular pulsed extraction column can successfully provide large throughput and can be made critically safe for fuel reprocessing. This investigation is to study the two phase flow characteristics in annular pulsed extraction column with four different annular width. 30% TBP (in kerosene)-water is used (water as continuous phase). Results show that modified Pratt correlation is valid under the experimental operation conditions for the annular pulsed extraction column. The characteristic velocity U K decreased with the increase of energy input and increased with the increase of the ratio of annular width to column diameter. Flooding velocity correlation is suggested. The deviation of the calculated values from the experimental data is within +20% for four annular width in a pulsed extraction column

  3. SLIP VELOCITY IN PULSED DISC AND DOUGHNUT EXTRACTION COLUMN

    Directory of Open Access Journals (Sweden)

    Mohammad Outokesh

    2011-09-01

    Full Text Available In the present work, slip velocity has been measured in a 76 mm diameter pulsed disc and doughnut extraction column for four different liquid-liquid systems. The effects of operating variables including pulsation intensity and dispersed and continuous phase flow rates on slip velocity have been investigated. The existence of three different operational regimes, namely mixersettler, transition, and emulsion regimes, was observed when the energy input was changed. Empirical correlations are derived for prediction of the slip velocity in terms of operating variables, physical properties of the liquid systems, and column geometry for different regimes. Good agreement between prediction and experiments was found for all operating conditions that were investigated.

  4. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors.

    Science.gov (United States)

    Liu, Jing; Gupta, Naveen K; Wise, Kensall D; Gianchandani, Yogesh B; Fan, Xudong

    2011-10-21

    This paper reports the investigation of a micro-gas chromatography (μGC) system that utilizes an array of miniaturized motionless Knudsen pumps (KPs) as well as microfabricated separation columns and optical detectors. A prototype system was built to achieve a flow rate of 1 mL min(-1) and 0.26 mL min(-1) for helium and dry air, respectively, when they were used as carrier gas. This system was then employed to evaluate GC performance compromises and demonstrate the ability to separate and detect gas mixtures containing analytes of different volatilities and polarities. Furthermore, the use of pressure programming of the KP array was demonstrated to significantly shorten the analysis time while maintaining a high detection resolution. Using this method, we obtained a high resolution detection of 5 alkanes of different volatilities within 5 min. Finally, we successfully detected gas mixtures of various polarities using a tandem-column μGC configuration by installing two on-column optical detectors to obtain complementary chromatograms.

  5. Effects of a malfunctional column on conventional and FeedCol-simulated moving bed chromatography performance.

    Science.gov (United States)

    Song, Ji-Yeon; Oh, Donghoon; Lee, Chang-Ha

    2015-07-17

    The effects of a malfunctional column on the performance of a simulated moving bed (SMB) process were studied experimentally and theoretically. The experimental results of conventional four-zone SMB (2-2-2-2 configuration) and FeedCol operation (2-2-2-2 configuration with one feed column) with one malfunctional column were compared with simulation results of the corresponding SMB processes with a normal column configuration. The malfunctional column in SMB processes significantly deteriorated raffinate purity. However, the extract purity was equivalent or slightly improved compared with the corresponding normal SMB operation because the complete separation zone of the malfunctional column moved to a lower flow rate range in zones II and III. With the malfunctional column configuration, FeedCol operation gave better experimental performance (up to 7%) than conventional SMB operation because controlling product purity with FeedCol operation was more flexible through the use of two additional operating variables, injection time and injection length. Thus, compared with conventional SMB separation, extract with equivalent or slightly better purity could be produced from FeedCol operation even with a malfunctional column, while minimizing the decrease in raffinate purity (less than 2%). Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Chemometrics applications in biotechnology processes: predicting column integrity and impurity clearance during reuse of chromatography resin.

    Science.gov (United States)

    Rathore, Anurag S; Mittal, Shachi; Lute, Scott; Brorson, Kurt

    2012-01-01

    Separation media, in particular chromatography media, is typically one of the major contributors to the cost of goods for production of a biotechnology therapeutic. To be cost-effective, it is industry practice that media be reused over several cycles before being discarded. The traditional approach for estimating the number of cycles a particular media can be reused for involves performing laboratory scale experiments that monitor column performance and carryover. This dataset is then used to predict the number of cycles the media can be used at manufacturing scale (concurrent validation). Although, well accepted and widely practiced, there are challenges associated with extrapolating the laboratory scale data to manufacturing scale due to differences that may exist across scales. Factors that may be different include: level of impurities in the feed material, lot to lot variability in feedstock impurities, design of the column housing unit with respect to cleanability, and homogeneity of the column packing. In view of these challenges, there is a need for approaches that may be able to predict column underperformance at the manufacturing scale over the product lifecycle. In case such an underperformance is predicted, the operators can unpack and repack the chromatography column beforehand and thus avoid batch loss. Chemometrics offers one such solution. In this article, we present an application of chemometrics toward the analysis of a set of chromatography profiles with the intention of predicting the various events of column underperformance including the backpressure buildup and inefficient deoxyribonucleic acid clearance. Copyright © 2012 American Institute of Chemical Engineers (AIChE).

  7. Simple determination of betaine, l-carnitine and choline in human urine using self-packed column and column-switching ion chromatography with nonsuppressed conductivity detection.

    Science.gov (United States)

    Wei, Dan; Zhu, Yan; Guo, Ming

    2018-02-01

    A sequential online extraction, clean-up and separation system for the determination of betaine, l-carnitine and choline in human urine using column-switching ion chromatography with nonsuppressed conductivity detection was developed in this work. A self-packed pretreatment column (50 × 4.6 mm, i.d.) was used for the extraction and clean-up of betaine, l-carnitine and choline. The separation was achieved using self-packed cationic exchange column (150 × 4.6 mm, i.d.), followed by nonsuppressed conductivity detection. Under optimized experimental conditions, the developed method presented good analytical performance, with excellent linearity in the range of 0.60-100 μg mL -1 for betaine, 0.75-100 μg mL -1 for l-carnitine and 0.50-100 μg mL -1 for choline, with all correlation coefficients (R 2 ) >0.99 in urine. The limits of detection were 0.15 μg mL -1 for betaine, 0.20 μg mL -1 for l-carnitine and 0.09 μg mL -1 for choline. The intra- and inter-day accuracy and precision for all quality controls were within ±10.32 and ±9.05%, respectively. Satisfactory recovery was observed between 92.8 and 102.0%. The validated method was successfully applied to the detection of urinary samples from 10 healthy people. The values detected in human urine using the proposed method showed good agreement with the measurement reported previously. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Determination of 3-hydroxypropylmercapturic acid in urine by three column-switching high-performance liquid chromatography with electrochemical detection using a diamond electrode.

    Science.gov (United States)

    Higashi, Kyohei; Shibasaki, Mana; Kuni, Kyoshiro; Uemura, Takeshi; Waragai, Masaaki; Uemura, Kenichi; Igarashi, Kazuei; Toida, Toshihiko

    2017-09-29

    A three column-switching high-performance liquid chromatography (HPLC) using an electrochemical detector (ECD) equipped with a diamond electrode was established to determine 3-hydroxypropylmercapturic acid (3-HPMA) in urine. An extracted urine sample was consecutively fractionated using a strong anion-exchange column (first column) and a C8 column (second column) via a switching valve before application on an Octa Decyl Silyl (ODS) column (third column), followed by ECD analysis. The% recovery of 3-HPMA standard throughout the three-column process and limit of detection (LOD) were 94±1% and 0.1pmol, respectively. A solid phase extraction step is required for the sensitive analysis of 3-HPMA in urine by column-switching HPLC-ECD despite a decreased% recovery (55%) of urine sample spiked with 100pmol of 3-HPMA. To test the utility of our column-switching HPLC-ECD method, 3-HPMA levels of 27 urine samples were determined, and the correlation between HPLC-ECD and LC-Electrospray ionization (ESI)-MS/MS method was examined. As a result, the median values of μmol 3-HPMA/g Creatinine (Cre) in urine obtained by column-switching HPLC-ECD and LC-MS/MS were 2.19±2.12μmol/g Cre and 2.13±3.38μmol/g Cre, respectively, and the calibration curve (y=1.5171x-1.007) exhibited good linearity within a defined range (r 2 =0.907). These results indicate that the combination of column-switching HPLC and ECD is a powerful tool for the specific, reliable detection of 3-HPMA in urine. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

    Energy Technology Data Exchange (ETDEWEB)

    Read, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sillerud, Colin Halliday [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

  10. Column chromatography with almecega resin: a project for experimental organic chemistry

    International Nuclear Information System (INIS)

    Vieira Junior, Gerardo Magela; Carvalho, Adonias Almeida; Gonzaga, Wellington de Abreu; Chaves, Mariana H.

    2007-01-01

    The use of natural products to demonstrate the silica gel column chromatography technique is proposed in the present article. It describes the separation of the triterpenes α- and β-amirin from the diol breine and maniladiol, obtained from almecega resin (Protium heptaphyllum March.). The experiment uses an accessible material, was accomplished in 4 h, and can be applied with success an the experimental course of organic chemistry for undergraduate students. (author)

  11. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    OpenAIRE

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large am...

  12. Flow rate dependent extra-column variance from injection in capillary liquid chromatography.

    Science.gov (United States)

    Aggarwal, Pankaj; Liu, Kun; Sharma, Sonika; Lawson, John S; Dennis Tolley, H; Lee, Milton L

    2015-02-06

    Efficiency and resolution in capillary liquid chromatography (LC) can be significantly affected by extra-column band broadening, especially for isocratic separations. This is particularly a concern in evaluating column bed structure using non-retained test compounds. The band broadening due to an injector supplied with a commercially available capillary LC system was characterized from experimental measurements. The extra-column variance from the injection valve was found to have an extra-column contribution independent of the injection volume, showing an exponential dependence on flow rate. The overall extra-column variance from the injection valve was found to vary from 34 to 23 nL. A new mathematical model was derived that explains this exponential contribution of extra-column variance on chromatographic performance. The chromatographic efficiency was compromised by ∼130% for a non-retained analyte because of injection valve dead volume. The measured chromatographic efficiency was greatly improved when a new nano-flow pumping system with integrated injection valve was used. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Longitudinal On-Column Thermal Modulation for Comprehensive Two-Dimensional Liquid Chromatography.

    Science.gov (United States)

    Creese, Mari E; Creese, Mathew J; Foley, Joe P; Cortes, Hernan J; Hilder, Emily F; Shellie, Robert A; Breadmore, Michael C

    2017-01-17

    Longitudinal on-column thermal modulation for comprehensive two-dimensional liquid chromatography is introduced. Modulation optimization involved a systematic investigation of heat transfer, analyte retention, and migration velocity at a range of temperatures. Longitudinal on-column thermal modulation was realized using a set of alkylphenones and compared to a conventional valve-modulator employing sample loops. The thermal modulator showed a reduced modulation-induced pressure impact than valve modulation, resulting in reduced baseline perturbation by a factor of 6; yielding a 6-14-fold improvement in signal-to-noise. A red wine sample was analyzed to demonstrate the potential of the longitudinal on-column thermal modulator for separation of a complex sample. Discrete peaks in the second dimension using the thermal modulator were 30-55% narrower than with the valve modulator. The results shown herein demonstrate the benefits of an active focusing modulator, such as reduced detection limits and increased total peak capacity.

  14. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    Science.gov (United States)

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large amount of samples must be analyzed fast using reliable and solvent-saving apparatus. The literature hereby described shows how the outstanding performances provided by core-shell particles column on a traditional HPLC instruments are comparable to those obtained with a costly UHPLC instrumentation, making this novel column a promising key tool in food analysis. PMID:27143972

  15. Influence of column type and chromatographic conditions on the ion-exchange chromatography of immunoglobulins.

    Science.gov (United States)

    Yang, Y B; Harrison, K

    1996-08-30

    Immunoglobulins are often purified by affinity chromatography. However, this technique is costly, can result in poor resolution for subclasses (or is only group specific), and leads to possible leaching of contaminants into the purified products. Ion-exchange chromatography has shown great potential and has found an increased usage in the purification of immunoglobulins. The aim of this study is to further understand the separation mechanism with emphasis on the influence of column type and chromatographic conditions on the peak shape, selectivity and changes in the elution patterns. Included are strong cation-exchange, strong anion-exchange and weak anion-exchange columns. Five immunoglobulin G antibodies were used as test probes. Some sera and ascites were also used in the study. Among the chromatographic conditions examined were mobile phase pH, buffer type, buffer concentration, gradient rate, and column temperature. Significant differences in the chromatographic behavior (elution pattern, peak shape and selectivity) of the test samples are discussed in regard to the column type and the chromatographic conditions.

  16. Novel design for centrifugal counter-current chromatography: VI. Ellipsoid column.

    Science.gov (United States)

    Gu, Dongyu; Yang, Yi; Xin, Xuelei; Aisa, Haji Akber; Ito, Yoichiro

    2015-01-01

    A novel ellipsoid column was designed for centrifugal counter-current chromatography. Performance of the ellipsoid column with a capacity of 3.4 mL was examined with three different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW), hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMH), and 12.5% (w/w) PEG1000 and 12.5% (w/w) dibasic potassium phosphate in water (PEG-DPP) each with suitable test samples. In dipeptide separation with BAW system, both stationary phase retention (Sf) and peak resolution (Rs) of the ellipsoid column were much higher at 0° column angle (column axis parallel to the centrifugal force) than at 90° column angle (column axis perpendicular to the centrifugal force), where elution with the lower phase at a low flow rate produced the best separation yielding Rs at 2.02 with 27.8% Sf at a flow rate of 0.07 ml/min. In the DNP-amino acid separation with HEMW system, the best results were obtained at a flow rate of 0.05 ml/min with 31.6% Sf yielding high Rs values at 2.16 between DNP-DL-glu and DNP-β-ala peaks and 1.81 between DNP-β-ala and DNP-L-ala peaks. In protein separation with PEG-DPP system, lysozyme and myolobin were resolved at Rs of 1.08 at a flow rate of 0.03 ml/min with 38.9% Sf. Most of those Rs values exceed those obtained from the figure-8 column under similar experimental conditions previously reported.

  17. A generalized theory of chromatography and multistep liquid extraction

    Science.gov (United States)

    Chizhkov, V. P.; Boitsov, V. N.

    2017-03-01

    A generalized theory of chromatography and multistep liquid extraction is developed. The principles of highly efficient processes for fine preparative separation of binary mixture components on a fixed sorbent layer are discussed.

  18. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  19. REUSABILITY OF BOND ELUT CERTIFY COLUMNS FOR THE EXTRACTION OF DRUGS FROM PLASMA

    NARCIS (Netherlands)

    CHEN, XH; FRANKE, JP; WIJSBEEK, J; DEZEEUW, RA

    1993-01-01

    The reusability of Bond Elut Certify columns for the extraction of toxicologically relevant drugs from plasma has been evaluated. Pentobarbital, hexobarbital, mepivacaine, trimipramine and clonazepam were selected as test drugs to represent various classes of drugs. The columns were regenerated

  20. Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2008-04-11

    The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in

  1. Methacrylate-bonded covalent-organic framework monolithic columns for high performance liquid chromatography.

    Science.gov (United States)

    Liu, Li-Hua; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2017-01-06

    Covalent-organic frameworks (COFs) are a newfangled class of intriguing microporous materials. Considering their unique properties, COFs should be promising as packing materials for high performance liquid chromatography (HPLC). However, the irregular shape and sub-micrometer size of COFs synthesized via the traditional methods render the main obstacles for the application of COFs in HPLC. Herein, we report the preparation of methacrylate-bonded COF monolithic columns for HPLC to overcome the above obstacles. The prepared COF bonded monolithic columns not only show good homogeneity and permeability, but also give high column efficiency, good resolution and precision for HPLC separation of small molecules including polycyclic aromatic hydrocarbons, phenols, anilines, nonsteroidal anti-inflammatory drugs and benzothiophenes. Compared with the bare polymer monolithic column, the COF bonded monolithic columns show enhanced hydrophobic, π-π and hydrogen bond interactions in reverse phase HPLC. The results reveal the great potential of COF bonded monoliths for HPLC and COFs in separation sciences. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Ready-made chromatography columns for extracellular vesicle isolation from plasma

    Directory of Open Access Journals (Sweden)

    Joanne Louise Welton

    2015-03-01

    Full Text Available Proteomic studies of circulating vesicles are hampered by difficulties in purifying vesicles from plasma and serum. Isolations are contaminated with high-abundance blood proteins that may mask genuine vesicular-associated proteins and/or simply provide misleading data. In this brief report, we explored the potential utility of a commercially available size exclusion chromatography column for rapid vesicle purification. We evaluated the performance of the column, with cancer cell line conditioned medium or healthy donor plasma, in terms of removing non-vesicular protein and enriching for vesicles exhibiting exosome characteristics. Serial fractions revealed a peak for typical exosomal proteins (CD9, CD81 etc. that preceded the peak for highly abundant proteins, including albumin, for either sample type, and harvesting only this peak would represent elimination of >95% of protein from the sample. The columns showed good reproducibility, and streamlining the workflow would allow the exosome-relevant material to be collected in less than 10 minutes. Surprisingly, however, subsequent post-column vesicle concentration steps whilst resulting in some protein loss also lead to low vesicle recoveries, with a net effect of reducing sample purity (assessed by the particle-to-protein ratio. The columns provide a convenient, reproducible and highly effective means of eliminating >95% of non-vesicular protein from biological fluid samples such as plasma.

  3. Practical issues relating to soil column chromatography for sorption parameter determination.

    Science.gov (United States)

    Bi, Erping; Schmidt, Torsten C; Haderlein, Stefan B

    2010-08-01

    Determination of sorption distribution coefficients (K(d)) of organic compounds by a dynamic soil column chromatography (SCC) method was developed and validated. Eurosoil 4, quartz, and alumina were chosen as exemplary packing materials. Heterocyclic aromatic compounds were selected in the validation of SCC. The prerequisites of SCC with regard to column dimension, packing procedure, and sample injection volume are discussed. Reproducible soil column packing was achieved by addition of a pre-column and an HPLC pump for subsequent compression of the packed material. Various methods to determine retention times from breakthrough curves are discussed and the use of the half mass method is recommended. To dilute soil with inert material can prevent column-clogging and help to complete experiments in a reasonable period of time. For the chosen probe compounds, quartz rather than alumina proved a suitable dilution material. Non-equilibrium issue can be overcome by conducting the experiments under different flowrates and/or performing numerical simulation. Copyright 2010 Elsevier Ltd. All rights reserved.

  4. High-performance liquid chromatography-mass spectrometry-based acetylcholinesterase assay for the screening of inhibitors in natural extracts

    NARCIS (Netherlands)

    de Jong, C.F.; Derks, R.J.E.; Bruyneel, B.; Niessen, W.M.A.; Irth, H.

    2006-01-01

    The present paper describes a High-performance liquid chromatography-mass spectrometry (LC-MS) methodology for the screening of acetylcholinesterase (AChE) inhibitors in natural extracts. AChE activity of sample components is monitored by a post-column biochemical assay that is based on the

  5. Histone fractionation by high-performance liquid chromatography on cyanoalkylsilane (CN) reverse-phase columns

    International Nuclear Information System (INIS)

    Gurley, L.R.; Prentice, D.A.; Valdez, J.G.; Spall, W.D.

    1983-01-01

    Previous work described conditions for the rapid fractionation of histones by high-performance liquid chromatography (HPLC) using a reverse-phase μBondapak C 18 column. That procedure resolved the major classes of histones with one exception: the more hydrophobic H2A variant, (MHP)H2A, was not resolved from the H4 histone class. This report extends that work describing experiments using a μBondapak CN column which better resolves the classes of histones from each other including the resolution of (MHP)H2A from the H4. In addition, the less hydrophobic H2A variant, (LHP)H2A, is partially resolved from the (MHP)H2A, and the less hydrophobic H3 variant, (LHP)H3, is resolved from the more hydrophobic H3 variant, (MHP)H3. Lower trifluoroacetic acid (TFA) concentrations (0.1%) in the eluting water/acetonitrile solvent were used with the CN column than were used with the C 18 column which increased the sensitivity of histone detection by ultraviolet absorption at 206 nm. Greater than 95% of the total [ 3 H]lysine-labeled protein applied to the CN column was eluted from the column. Contaminating nonhistone proteins were found to chromatograph in the region of histone elution. These were greatly reduced by isolating nuclei prior to histone preparation. The fractionation of the histones appears to be based on the hydrophobic properties of the proteins. The histone fractions (identified by their electrophoretic mobilities) were eluted from the CN column in the following order: H1, H2B, (LHP)H2A, (MHP)H2A, H4, (LHP)H3, and (MHP)H3. Phosphorylated and acetylated histone species were not resolved from their unmodified parental species

  6. Instrument for Solvent Extraction and Analysis (ISEE) of Organics from Regolith Simulant Using Supercritical Fluid Extraction and Chromatography

    Science.gov (United States)

    Franco, Carolina; Hintze, Paul E.

    2017-01-01

    ISEE is an instrument with the potential to perform extractions from regolith found on the surface of asteroids and planets, followed by characterization and quantitation of the extracts using supercritical fluid extraction (SFE) and chromatography (SFC). SFE is a developed technique proven to extract a wide range of organic compounds. SFC is similar to High Performance Liquid Chromatography (HPLC) but has the advantage of performing chiral separations without needing to derivatize the chiral compounds. CO2 will be the solvent for both stages as it is readily available in the Mars atmosphere. ISEE will capture CO2 from the environment, and use it for SFE and SFC. If successful, this would allow ISEE to perform analysis of organic compounds without using consumables. This paper will present results on a preliminary, proof-of-principle effort to use SFE and SFC to extract and analyze lunar regolith simulant spiked with organic compounds representing a range of organics that ISEE would expect to characterize. An optimization of variables for the extraction of the organics from the spiked regolith was successfully developed, using 138 bar pressure and 40 C temperature. The extraction flow rate was optimized at 2% SLPM with 30% methanol modifier. The extractions were successful with a value of 77.3+/- 0.9% of organics extracted. However, the recovery of organics after the extraction was very low with only 48.5+/-14.2%. Moreover, three columns were selected to analyze multiple samples at a time; two of them are Viridis HSS C18 SB and Torus DIOL, and the third column, specific for chiral separations, has not yet been selected yet.

  7. The basic characteristics of TRPO-GDX-301 resin extraction chromatography and its application in analysis of uranium ore

    International Nuclear Information System (INIS)

    Jin Wenlong; Yao Mingxia.

    1986-01-01

    The basic characteristic, including capacity of column, loading quality of extraction agent, relationship between flow-rate of solution and height of theorical tower plate, leakage of extraction agent, separation behavior of uranium, of TRPO-extraction chromatography for separation of uranium has been inveistigated. The microamount of uranium on column can be eluted with mixed complex solution at pH 5.8-6.2 and determined by 5-Br-PADAP spectrophotometry. The method is simple and easy to operate. It has reasonable precision and accuracy. It is very suitable for determination of 0.002-0.4% uranium in ore

  8. Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification

    Science.gov (United States)

    Murphy, Patrick J. M.; Stone, Orrin J.; Anderson, Michelle E.

    2011-01-01

    In contrast to other chromatographic methods for purifying proteins (e.g. gel filtration, affinity, and ion exchange), hydrophobic interaction chromatography (HIC) commonly requires experimental determination (referred to as screening or "scouting") in order to select the most suitable chromatographic medium for purifying a given protein 1. The method presented here describes an automated approach to scouting for an optimal HIC media to be used in protein purification. HIC separates proteins and other biomolecules from a crude lysate based on differences in hydrophobicity. Similar to affinity chromatography (AC) and ion exchange chromatography (IEX), HIC is capable of concentrating the protein of interest as it progresses through the chromatographic process. Proteins best suited for purification by HIC include those with hydrophobic surface regions and able to withstand exposure to salt concentrations in excess of 2 M ammonium sulfate ((NH4)2SO4). HIC is often chosen as a purification method for proteins lacking an affinity tag, and thus unsuitable for AC, and when IEX fails to provide adequate purification. Hydrophobic moieties on the protein surface temporarily bind to a nonpolar ligand coupled to an inert, immobile matrix. The interaction between protein and ligand are highly dependent on the salt concentration of the buffer flowing through the chromatography column, with high ionic concentrations strengthening the protein-ligand interaction and making the protein immobile (i.e. bound inside the column) 2. As salt concentrations decrease, the protein-ligand interaction dissipates, the protein again becomes mobile and elutes from the column. Several HIC media are commercially available in pre-packed columns, each containing one of several hydrophobic ligands (e.g. S-butyl, butyl, octyl, and phenyl) cross-linked at varying densities to agarose beads of a specific diameter 3. Automated column scouting allows for an efficient approach for determining which HIC media

  9. Determination of the Antibiotic Oxytetracycline in Commercial Milk by Solid-Phase Extraction: A High-Performance Liquid Chromatography (HPLC) Experiment for Quantitative Instrumental Analysis

    Science.gov (United States)

    Mei-Ratliff, Yuan

    2012-01-01

    Trace levels of oxytetracylcine spiked into commercial milk samples are extracted, cleaned up, and preconcentrated using a C[subscript 18] solid-phase extraction column. The extract is then analyzed by a high-performance liquid chromatography (HPLC) instrument equipped with a UV detector and a C[subscript 18] column (150 mm x 4.6 mm x 3.5 [mu]m).…

  10. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    Science.gov (United States)

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-01-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan. PMID:27470880

  11. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    Science.gov (United States)

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-07-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan.

  12. A flow-through column electrolytic cell for supercritical fluid chromatography.

    Science.gov (United States)

    Yamamoto, Kazuhiro; Ueki, Tatsuya; Higuchi, Naoyuki; Takahashi, Kouji; Kotani, Akira; Hakamata, Hideki

    2017-10-01

    A novel flow-through column electrolytic cell was proposed as a detector to obtain current signals for supercritical fluid chromatography. The electrochemical cell consisted of two electrodes and its holder, and a working and a counter electrode were fabricated from 192 carbon strings, which were composed of 400 carbon fibers of 10 μm in diameter filled into a heat-shrinkable tube. These electrodes were placed in the center of a holder made from polyether ether ketone blocks and they were separated by polytetrafluoroethylene membrane filters. To evaluate the sensitivity of this cell, a standard solution of ferrocene was injected into the supercritical fluid chromatography system connected to the electrolytic cell. The ferrocene was eluted through a silica gel column using a mixture of a mobile phase of supercritical CO 2 and a modifier of methanol containing ammonium acetate. The current peak area of ferrocene correlated to the ferrocene concentration in the range of 10-400 μmol/L (r = 0.999). Moreover, the limit of detection on the column estimated from a signal-to-noise ratio of 3 was 9.8  × 10 -13  mol. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Simultaneous determination of metoprolol and metabolites in urine by capillary column gas chromatography as oxazolidineone and trimethylsilyl derivatives.

    Science.gov (United States)

    Gyllenhaal, O; Hoffmann, K J

    1984-08-10

    A method for the determination of metoprolol and its main metabolites in urine is presented. The method comprises derivatization of the aminopropanol side-chain with phosgene at alkaline pH and isolation in an organic phase at acidic pH. After trimethylsilylation, separation and quantification are performed by capillary column gas chromatography with flame ionization detection. The reaction is performed at pH 12 with 60 microliters of 2 M phosgene in toluene added in three portions. Diethyl ether--dichloromethane is used as extraction medium and bis(trimethylsilyl) acetamide as silylating agent. With spiked samples linear standard curves were obtained for metoprolol and three of its main metabolites with a detection limit varying between 4 and 20 mumol/l of urine. The method was applied to urine samples from a normal individual who had taken 292 mumol of metoprolol as tartrate.

  14. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects.

    Science.gov (United States)

    Schweiger, Susanne; Jungbauer, Alois

    2018-02-16

    Small pre-packed columns are commonly used to estimate the optimum run parameters for pilot and production scale. The question arises if the experiments obtained with these columns are scalable, because there are substantial changes in extra column volume when going from a very small scale to a benchtop column. In this study we demonstrate the scalability of pre-packed disposable and non-disposable columns of volumes in the range of 0.2-20 ml packed with various media using superficial velocities in the range of 30-500 cm/h. We found that the relative contribution of extra column band broadening to total band broadening was not only high for columns with small diameters, but also for columns with a larger volume due to their wider diameter. The extra column band broadening can be more than 50% for columns with volumes larger than 10 ml. An increase in column diameter leads to high additional extra column band broadening in the filter, frits, and adapters of the columns. We found a linear relationship between intra column band broadening and column length, which increased stepwise with increases in column diameter. This effect was also corroborated by CFD simulation. The intra column band broadening was the same for columns packed with different media. An empirical engineering equation and the data gained from the extra column effects allowed us to predict the intra, extra, and total column band broadening just from column length, diameter, and flow rate. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  15. Affinity-based screening of combinatorial libraries using automated, serial-column chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D.M.; Williams, K.P.; McGuinness, B. [PerSeptive Biosystems, Framingham, MA (United States)] [and others

    1996-04-01

    The authors have developed an automated serial chromatographic technique for screening a library of compounds based upon their relative affinity for a target molecule. A {open_quotes}target{close_quotes} column containing the immobilized target molecule is set in tandem with a reversed-phase column. A combinatorial peptide library is injected onto the target column. The target-bound peptides are eluted from the first column and transferred automatically to the reversed-phase column. The target-specific peptide peaks from the reversed-phase column are identified and sequenced. Using a monoclonal antibody (3E-7) against {beta}-endorphin as a target, we selected a single peptide with sequence YGGFL from approximately 5800 peptides present in a combinatorial library. We demonstrated the applicability of the technology towards selection of peptides with predetermined affinity for bacterial lipopolysaccharide (LPS, endotoxin). We expect that this technology will have broad applications for high throughput screening of chemical libraries or natural product extracts. 21 refs., 4 figs.

  16. Immunoaffinity column clean-up and thin layer chromatography for determination of ochratoxin A in green coffee.

    Science.gov (United States)

    Santos, E A; Vargas, E A

    2002-05-01

    An immunoaffinity clean-up-based method for determining ochratoxin A (OTA) in green coffee aiming at one-dimensional thin layer chromatography (TLC) analysis was established. OTA was extracted with a mixture of methanol and aqueous sodium hydrogen carbonate solution, purified through an immunoaffinity column, separated on normal or reversed-phase (RP) TLC plates and detected and quantified by visual and densitometric analysis. The linear equation of the standard calibration curve by densitometric analysis gave R(2) > 0.999 (0.04-84 ng). The mean recovery (R) of OTA from spiked samples (1.8-109 microg kg(-1)) by densitometric and visual analyses were 98.4 and 103.8%, respectively. The relative standard deviations (RSD) for densitometric and visual analysis varied from 1.1 to 24.9% and from 0.0 to 18.8%, respectively. The RSD for naturally contaminated samples by densitometry (three levels of contamination, n = 3) varied from 11.1 to 18.1%. The correlation (R(2)) between high-performance liquid chromatography (HPLC) and densitometry, and between visual and densitometric analysis for spiked samples were > 0.99. The limit of detection (LOD) of the method was 0.5 microg kg(-1) for normal TLC. Toluene-ethyl acetate-88% formic acid (6:3:1 v/v/v) and acetonitrile-methanol-water-glacial acetic acid (35:35:29:10 v/v/v/v) were regarded as the suitable TLC solvents for eluting both standards and samples on normal and RP TLC plates, respectively. Toluene-acetic acid (99:1 v/v) was chosen as the spotting solvent among several others for giving the best sensitivity and resolution of OTA on TLC plates as well as the best recovery of OTA from standard and sample extract residues. Preliminary studies were carried out to investigate the reuse of the immunoaffinity column and the interference of caffeine in the OTA recovery.

  17. Chelating agents as stationary phase in extraction chromatography, ch. 11

    International Nuclear Information System (INIS)

    Sebesta, F.

    1975-01-01

    Chelating agents have been used largely in extraction chromatography for separations related to activation analysis, for concentration of metals from dilute solutions, and for preparation of radiochemically pure or carrier-free radionuclides. This review deals with the theory of extraction by chelating agents, the experimental technique, and the chelating agents and systems used (β-diketones, oximes, hydroxamic acid, dithizone and diethyldithiocarbamic acid)

  18. Mechanized Sephadex LH-20 multiple column chromatography as a prerequisite for automated multi-steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Sippell, W.G.; Bidlingmaier, F.; Knorr, D.

    1978-01-01

    To establish a procedure for the simultaneous determination of all major corticosteroid hormones and their immediate biological precursors in the same plasma sample, two different mechanized methods for the simultaneous isolation of aldosterone (A), corticosterone (B), 11-deoxycorticosterone (DOC), progesterone (P), 17-hydroxyprogesterone (17-OHP), 11-deoxycortisol (S), cortisol (F) and cortisone (E) from the methylene chloride extracts of 0.1 to 2.0ml plasma samples have been developed. In method I, steroids are separated with methylene chloride:methanol=98:2 as solvent system on 60-cm Sephadex LH-20 columns, up to eight of which are eluted in parallel using a multi-channel peristaltic pump and individual flow-rate control (40ml/h) by capillary valves and micro-flowmeters. Method II, on the other hand, utilizes the same solvent system on ten 75-cm LH-20 columns which are eluted in reversed flow simultaneously by a ten-channel, double-piston pump that precisely maintains an elution flow rate of 40ml/h in every column. In both methods, eluate fractions of each of the isolated steroids are automatically pooled and collected from all parallel columns by one programmable linear fraction collector. As a result of the high reproducibility of the elution patterns, both between different parallel columns and between 30 to 40 consecutive elutions, mean recoveries of tritiated steroids including extraction are 60 to 84% after a single separation and still over 50% after an additional separation on 40-cm LH-20 columns, with coefficients of variation below 15% (method II). Thus, the eight steroids can be completely isolated from each of ten plasma extracts within 3 to 4 hours, yielding 80 samples readily prepared for subsequent quantitation by radioimmunoassay. (author)

  19. Detection of uranium extraction zone by axial temperature profiles in a pulsed column for Purex process

    International Nuclear Information System (INIS)

    Tsukada, T.; Takahashi, K.

    1991-01-01

    A new method was presented for detecting uranium extraction zone in a pulsed column by means of measuring axial temperature profile originated from reaction heat during uranium extraction. Key parameters of the temperature profiles were estimated with a code developed for calculating temperature profiles in a direct-contact heat exchanger such as a pulsed column, and were verified using data from a small pulsed column simulating reaction heat with injecting hot water. Finally, the results were compared with those from an actual uranium extraction tests, indicating that the method presented was promising for detecting uranium extraction zone in a pulsed column. (author)

  20. Use of a pulsed column with discs and crowns for uranium extraction from phosphoric acid

    International Nuclear Information System (INIS)

    1982-04-01

    The physico-chemistry of the system phosphoric acid-uranium-dioctylpyrophosphoric acid is studied for the determination of analytical methods and extraction parameters (oxidation state of uranium and iron, phosphorus concentration, extractant concentration). Extraction is then realized on a pilot scale with a liquid-liquid extraction column 4m high and of 50 mm in diameter with a column packing made of discs and crowns. Column efficiency is evaluated by studying uranium transfer as a function of operating conditions. The results obtained are extrapolated to an industrial scale and a comparative economic evaluation is made between a pulsed column and a mixer-settler [fr

  1. Identification of glycosaminoglycans using high-performance liquid chromatography on a hydroxyapatite column.

    Science.gov (United States)

    Narita, H; Takeda, Y; Takagaki, K; Nakamura, T; Harata, S; Endo, M

    1995-11-20

    Glycosaminoglycans (heparin, heparan sulfate, dermatan sulfate, chondroitin sulfate, and hyaluronic acid) were labeled with a fluorescent reagent, 2-aminopyridine. The fluoro-labeled glycosaminoglycans were subjected to high-performance liquid chromatography on a hydroxyapatite column. The binding property of each glycosaminoglycan to hydroxyapatite was different. The structural properties of glycosaminoglycans bound to hydroxyapatite were then investigated using chemical desulfated or enzymic depolymerized glycosaminoglycans. This revealed that the sulfate content and molecular weight of the glycosaminoglycans correlated with their binding properties to hydroxyapatite. Desulfated dermatan sulfate but not desulfated chondroitin 6-sulfate bound to the hydroxyapatite. These data indicate that iduronic acid residues of glycosaminoglycans are important for the binding property. The method described which uses hydroxyapatite columns facilitates rapid separation and microanalysis of the glycosaminoglycans, especially dermatan sulfate and chondroitin sulfate.

  2. A simple subcritical chromatographic test for an extended ODS high performance liquid chromatography column classification.

    Science.gov (United States)

    Lesellier, Eric; Tchapla, Alain

    2005-12-23

    This paper describes a new test designed in subcritical fluid chromatography (SFC) to compare the commercial C18 stationary phase properties. This test provides, from a single analysis of carotenoid pigments, the absolute hydrophobicity, the silanol activity and the steric separation factor of the ODS stationary phases. Both the choice of the analytical conditions and the validation of the information obtained from the chromatographic measurements are detailed. Correlations of the carotenoid test results with results obtained from other tests (Tanaka, Engelhard, Sander and Wise) performed both in SFC and HPLC are discussed. Two separation factors, calculated from the retention of carotenoid pigments used as probe, allowed to draw a first classification diagram. Columns, which present identical chromatographic behaviors are located in the same area on this diagram. This location can be related to the stationary phase properties: endcapping treatments, bonding density, linkage functionality, specific area or silica pore diameter. From the first classification, eight groups of columns are distinguished. One group of polymer coated silica, three groups of polymeric octadecyl phases, depending on the pore size and the endcapping treatment, and four groups of monomeric stationary phases. An additional classification of the four monomeric groups allows the comparison of these stationary phases inside each group by using the total hydrophobicity. One hundred and twenty-nine columns were analysed by this simple and rapid test, which allows a comparison of columns with the aim of helping along their choice in HPLC.

  3. Isolation and identification of arctiin and arctigenin in leaves of burdock (Arctium lappa L.) by polyamide column chromatography in combination with HPLC-ESI/MS.

    Science.gov (United States)

    Liu, Shiming; Chen, Kaoshan; Schliemann, Willibald; Strack, Dieter

    2005-01-01

    A simple method involving polyamide column chromatography in combination with HPLC-PAD and HPLC-ESI/MS for isolating and identifying two kinds of lignans, arctiin and arctigenin, in the leaves of burdock (Arctium lappa L.) has been established. After extraction of burdock leaves with 80% methanol, the aqueous phase of crude extracts was partitioned between water and chloroform and the aqueous phase was fractionated on a polyamide glass column. The fraction, eluting with 100% methanol, was concentrated and gave a white precipitate at 4 degrees C from which two main compounds were purified by semi-preparative HPLC. In comparison with the UV and ESI-MS spectra and the HPLC retention time of authentic standards, the compounds were determined to be arctiin and arctigenin. The extraction/separation technique was validated using an internal standard method.

  4. Enantioselective Analytical- and Preparative-Scale Separation of Hexabromocyclododecane Stereoisomers Using Packed Column Supercritical Fluid Chromatography

    Directory of Open Access Journals (Sweden)

    Nicole Riddell

    2016-11-01

    Full Text Available Hexabromocyclododecane (HBCDD is an additive brominated flame retardant which has been listed in Annex A of the Stockholm Convention for elimination of production and use. It has been reported to persist in the environment and has the potential for enantiomer-specific degradation, accumulation, or both, making enantioselective analyses increasingly important. The six main stereoisomers of technical HBCDD (i.e., the (+ and (− enantiomers of α-, β-, and γ-HBCDD were separated and isolated for the first time using enantioselective packed column supercritical fluid chromatography (pSFC separation methods on a preparative scale. Characterization was completed using published chiral liquid chromatography (LC methods and elution profiles, as well as X-ray crystallography, and the isolated fractions were definitively identified. Additionally, the resolution of the enantiomers, along with two minor components of the technical product (δ- and ε-HBCDD, was investigated on an analytical scale using both LC and pSFC separation techniques, and changes in elution order were highlighted. Baseline separation of all HBCDD enantiomers was achieved by pSFC on an analytical scale using a cellulose-based column. The described method emphasizes the potential associated with pSFC as a green method of isolating and analyzing environmental contaminants of concern.

  5. Enantioselective Analytical- and Preparative-Scale Separation of Hexabromocyclododecane Stereoisomers Using Packed Column Supercritical Fluid Chromatography.

    Science.gov (United States)

    Riddell, Nicole; Mullin, Lauren Gayle; van Bavel, Bert; Ericson Jogsten, Ingrid; McAlees, Alan; Brazeau, Allison; Synnott, Scott; Lough, Alan; McCrindle, Robert; Chittim, Brock

    2016-11-10

    Hexabromocyclododecane (HBCDD) is an additive brominated flame retardant which has been listed in Annex A of the Stockholm Convention for elimination of production and use. It has been reported to persist in the environment and has the potential for enantiomer-specific degradation, accumulation, or both, making enantioselective analyses increasingly important. The six main stereoisomers of technical HBCDD (i.e., the (+) and (-) enantiomers of α-, β-, and γ-HBCDD) were separated and isolated for the first time using enantioselective packed column supercritical fluid chromatography (pSFC) separation methods on a preparative scale. Characterization was completed using published chiral liquid chromatography (LC) methods and elution profiles, as well as X-ray crystallography, and the isolated fractions were definitively identified. Additionally, the resolution of the enantiomers, along with two minor components of the technical product (δ- and ε-HBCDD), was investigated on an analytical scale using both LC and pSFC separation techniques, and changes in elution order were highlighted. Baseline separation of all HBCDD enantiomers was achieved by pSFC on an analytical scale using a cellulose-based column. The described method emphasizes the potential associated with pSFC as a green method of isolating and analyzing environmental contaminants of concern.

  6. Rapid column extraction method for actinides and strontium in fish and other animal tissue samples

    International Nuclear Information System (INIS)

    Maxwell III, S.L.; Faison, D.M.

    2008-01-01

    The analysis of actinides and radiostrontium in animal tissue samples is very important for environmental monitoring. There is a need to measure actinide isotopes and strontium with very low detection limits in animal tissue samples, including fish, deer, hogs, beef and shellfish. A new, rapid separation method has been developed that allows the measurement of plutonium, neptunium, uranium, americium, curium and strontium isotopes in large animal tissue samples (100-200 g) with high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin R , TRU Resin R and DGA Resin R cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), neptunium (Np), uranium (U), americium (Am), and curium (Cm) using a single multi-stage column combined with alphaspectrometry. Strontium is collected on Sr Resin R from Eichrom Technologies (Darien, IL, USA). After acid digestion and furnace heating of the animal tissue samples, the actinides and 89/90 Sr are separated using column extraction chromatography. This method has been shown to be effective over a wide range of animal tissue matrices. Vacuum box cartridge technology with rapid flow rates is used to minimize sample preparation time. (author)

  7. Applications of DHDECMP extraction chromatography to nuclear analytical chemistry

    International Nuclear Information System (INIS)

    Marsh, S.F.; Simi, O.R.

    1981-01-01

    Dihexyl-N,N-diethylcarbamylmethylenephosphonate (DHDECMP) is a highly selective extractant for actinides and lanthanides. This reagent, extensively studied for process-scale operations, also has valuable analytical applications. Extraction chromatographic columns of DHDECMP, supported on inert, porous, polymer beads effectively separate most metallic impurity elements from the retained inner transition elements. The retained elements can be separated into individual fractions of (1) lanthanides, (2) americium, (3) plutonium, and (4) uranium by mixed-solvent anion exchange

  8. Separation of Th(IV) and U(VI) by extraction chromatography

    International Nuclear Information System (INIS)

    Nadkarni, M.N.; Mayankutty, P.C.; Pillai, N.S.

    1984-01-01

    Application of extraction chromatography to the analytical separation of Th(IV) and U(VI) has been investigated. The stationary phase was a macroporous resin Amberlite XE-270 impregnated with undiluted tri-n-butylphosphate (TBP) and the mobile phase was either 5.0M HNO 3 or 6M HCl. Separation of traces of Th(IV) from large quantities of U(VI) was achieved on a laboratory column by elution of the absorbed Th(IV) with 6M HCl. (author)

  9. [Online enrichment ability of restricted-access column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride].

    Science.gov (United States)

    Zhang, Xiaohui; Wang, Rong; Xie, Hua; Yin, Qiang; Li, Xiaoyun; Jia, Zhengping; Wu, Xiaoyu; Zhang, Juanhong; Li, Wenbin

    2013-05-01

    The online enrichment ability of the restricted-access media (RAM) column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride in plasma was studied. The RAM-HPLC system consisted of an RAM column as enrichment column and a C18 column as analytical column coupled via the column switching technique. The effects of the injection volume on the peak area and the systematic pressure were studied. When the injection volume was less than 100 microL, the peak area increased with the increase of the injection volume. However, when the injection volume was more than 80 microL, the pressure of whole system increased obviously. In order to protect the whole system, 80 microL was chosen as the maximum injection volume. The peak areas of ordinary injection and the large volume injection showed a good linear relationship. The enrichment ability of RAM-HPLC system was satisfactory. The system was successfully used for the separation and detection of the trace benazepril hydrochloride in rat plasma after its administration. The sensitivity of HPLC can be improved by RAM pre-enrichment. It is a simple and economic measurement method.

  10. Preparation of polymer monolithic column functionalized by arsonic acid groups for mixed-mode capillary liquid chromatography.

    Science.gov (United States)

    Qin, Zhang-Na; Yu, Qiong-Wei; Wang, Ren-Qi; Feng, Yu-Qi

    2018-04-27

    A mixed-mode polymer monolithic column functionalized by arsonic acid groups was prepared by single-step in situ copolymerization of monomers p-methacryloylaminophenylarsonic acid (p-MAPHA) and pentaerythritol triacrylate (PETA). The prepared poly(p-MAPHA-co-PETA) monolithic column has a homogeneous monolithic structure with good permeability and mechanical stability. Zeta potential measurements reveal that the monolithic stationary phase holds a negative surface charge when the mobile phase resides in the pH range of 3.0-8.0. The retention mechanisms of prepared monolithic column are explored by the separation of selected polycyclic aromatic hydrocarbons (PAHs), nucleosides, and three basic compounds. The results indicate that the column functions in three different separation modes associated with reversed-phase chromatography based on hydrophobic interaction, hydrophilic interaction chromatography, and cation-exchange chromatography. The column efficiency of prepared monolithic column is estimated to be 70,000 and 76,000 theoretical plates/m for thiourea and naphthalene, respectively, at a linear flow velocity of 0.85 mm/s using acetonitrile/H 2 O (85/15, v/v) as the mobile phase. Furthermore, an analysis of the retention factors obtained for the PAHs indicates that the prepared monolithic column exhibits good reproducibility with relative standard deviations of 2.9%, 4.0%, and 4.7% based on run-to-run injections, column-to-column preparation, and batch-to-batch preparation, respectively. Finally, we investigate the separation performance of the proposed monolithic column for select phenols, sulfonamides, nucleobases and nucleosides. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Neptunium separation in trace levels from uranium solutions by extraction chromatography

    International Nuclear Information System (INIS)

    Figols, M.E.B.

    1991-01-01

    Neptunium and uranium behavior in extraction chromatography system, aiming the separation of microquantities of neptunium from uranyl nitrate solutions is described. Tri-n-octylamina (TOA), tri-n-butylphosphate (TBP), thenoyltrifluoroacetone (TTA) as stationary phase, alumina, Voltalef-UF-300, silica as support material were verified. The impregnation conditions as well as the best stationary phase/support material ratio were established. TBP/alumina, TBP/Voltalef and TOA/alumina system were selected to uranium and neptunium separation studies. In the system using TBP as extractant agent uranium and neptunium separation was reached by selective elution after the retention of both elements on the column. U-Np separation by selective retention of Np was possible with TOA system. The capacity of the column was the 66.6 mg U/mL and 191.6mg U/mL for the TBP/alumina and TBP/Voltalef systems, respectively. An application of extraction chromatography system in the final phase of irradiated uranium treatment process is proposed. (author)

  12. Two-dimensional liquid chromatography consisting of twelve second-dimension columns for comprehensive analysis of intact proteins.

    Science.gov (United States)

    Ren, Jiangtao; Beckner, Matthew A; Lynch, Kyle B; Chen, Huang; Zhu, Zaifang; Yang, Yu; Chen, Apeng; Qiao, Zhenzhen; Liu, Shaorong; Lu, Joann J

    2018-05-15

    A comprehensive two-dimensional liquid chromatography (LCxLC) system consisting of twelve columns in the second dimension was developed for comprehensive analysis of intact proteins in complex biological samples. The system consisted of an ion-exchange column in the first dimension and the twelve reverse-phase columns in the second dimension; all thirteen columns were monolithic and prepared inside 250 µm i.d. capillaries. These columns were assembled together through the use of three valves and an innovative configuration. The effluent from the first dimension was continuously fractionated and sequentially transferred into the twelve second-dimension columns, while the second-dimension separations were carried out in a series of batches (six columns per batch). This LCxLC system was tested first using standard proteins followed by real-world samples from E. coli. Baseline separation was observed for eleven standard proteins and hundreds of peaks were observed for the real-world sample analysis. Two-dimensional liquid chromatography, often considered as an effective tool for mapping proteins, is seen as laborious and time-consuming when configured offline. Our online LCxLC system with increased second-dimension columns promises to provide a solution to overcome these hindrances. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    Science.gov (United States)

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Temperature-assisted On-column Solute Focusing: A General Method to Reduce Pre-column Dispersion in Capillary High Performance Liquid Chromatography

    Science.gov (United States)

    Groskreutz, Stephen R.; Weber, Stephen G.

    2014-01-01

    Solvent-based on-column focusing is a powerful and well known approach for reducingthe impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created thatlead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retentionTASF is used effectivelyto compress injection bands at the head of the column through the transient reduction in column temperature to 5 °C for a defined 7 mm segment of a 6 cm long 150 μm I.D. column. Following the 30 second focusing time, the column temperature is increased rapidly to the separation temperature of 60 °C releasing the focused band of analytes. We developed a model tosimulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance.All samples have solvent compositions matching the mobile phase. Over the 45 to 1050 nL injection volume range evaluated, TASF reducesthe peak width for all soluteswith k’ greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45 nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it canbe used where on-column focusing is required, but where implementation of solvent-based focusing is difficult. PMID:24973805

  15. Analysis of perfluorinated carboxylic acids in soils II: optimization of chromatography and extraction.

    Science.gov (United States)

    Washington, John W; Henderson, W Matthew; Ellington, J Jackson; Jenkins, Thomas M; Evans, John J

    2008-02-15

    With the objective of detecting and quantitating low concentrations of perfluorinated carboxylic acids (PFCAs), including perfluorooctanoic acid (PFOA), in soils, we compared the analytical suitability of liquid chromatography columns containing three different stationary phases, two different liquid chromatography-tandem mass spectrometry (LC/MS/MS) systems, and eight combinations of sample-extract pretreatments, extractions and cleanups on three test soils. For the columns and systems we tested, we achieved the greatest analytical sensitivity for PFCAs using a column with a C(18) stationary phase in a Waters LC/MS/MS. In this system we achieved an instrument detection limit for PFOA of 270 ag/microL, equating to about 14 fg of PFOA on-column. While an elementary acetonitrile/water extraction of soils recovers PFCAs effectively, natural soil organic matter also dissolved in the extracts commonly imparts significant noise that appears as broad, multi-nodal, asymmetric peaks that coelute with several PFCAs. The intensity and elution profile of this noise is highly variable among soils and it challenges detection of low concentrations of PFCAs by decreasing the signal-to-noise contrast. In an effort to decrease this background noise, we investigated several methods of pretreatment, extraction and cleanup, in a variety of combinations, that used alkaline and unbuffered water, acetonitrile, tetrabutylammonium hydrogen sulfate, methyl-tert-butyl ether, dispersed activated carbon and solid-phase extraction. For the combined objectives of complete recovery and minimization of background noise, we have chosen: (1) alkaline pretreatment; (2) extraction with acetonitrile/water; (3) evaporation to dryness; (4) reconstitution with tetrabutylammonium-hydrogen-sulfate ion-pairing solution; (5) ion-pair extraction to methyl-tert-butyl ether; (6) evaporation to dryness; (7) reconstitution with 60/40 acetonitrile/water (v/v); and (8) analysis by LC/MS/MS. Using this method, we

  16. Modeling on-column reduction of trisulfide bonds in monoclonal antibodies during protein A chromatography.

    Science.gov (United States)

    Ghose, Sanchayita; Rajshekaran, Rupshika; Labanca, Marisa; Conley, Lynn

    2017-01-06

    Trisulfides can be a common post-translational modification in many recombinant monoclonal antibodies. These are a source of product heterogeneity that add to the complexity of product characterization and hence, need to be reduced for consistent product quality. Trisulfide bonds can be converted to the regular disulfide bonds by incorporating a novel cysteine wash step during Protein A affinity chromatography. An empirical model is developed for this on-column reduction reaction to compare the reaction rates as a function of typical operating parameters such as temperature, cysteine concentration, reaction time and starting level of trisulfides. The model presented here is anticipated to assist in the development of optimal wash conditions for the Protein A step to effectively reduce trisulfides to desired levels. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions.

    Science.gov (United States)

    Vanderlinden, Kim; Broeckhoven, Ken; Vanderheyden, Yoachim; Desmet, Gert

    2016-04-15

    We report on the results of an experimental and theoretical study of the effect of the extra-column band broadening (ECBB) on the performance of narrow-bore columns filled with the smallest particles that are currently commercially available. Emphasis is on the difference between the effect of ECBB under gradient and isocratic conditions, as well as on the ability to model and predict the ECBB effects using well-established band broadening expressions available from the theory of chromatography. The fine details and assumptions that need to be taken into account when using these expressions are discussed. The experiments showed that, the steeper the gradient, the more pronounced the extra-column band broadening losses become. Whereas the pre-column band broadening can in both isocratic and gradient elution be avoided by playing on the possibilities to focus the analytes on top of the column (e.g. by using the POISe injection method when running isocratic separations), the post-column extra-column band broadening is inescapable in both cases. Inducing extra-column band broadening by changing the inner diameter of the post-column tubing from 65 to 250 μm, we found that all peaks in the chromatogram are strongly affected (around a factor of 1.9 increase in relative peak width) when running steep gradients, while usually only the first eluting peak was affected in the isocratic mode or when running shallow gradients (factor 1.6-1.8 increase in relative peak width for the first eluting analyte). Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Understanding and diminishing the extra-column band broadening effects in supercritical fluid chromatography.

    Science.gov (United States)

    De Pauw, Ruben; Shoykhet Choikhet, Konstantin; Desmet, Gert; Broeckhoven, Ken

    2015-07-17

    Supercritical fluid chromatography, where a low-viscosity mobile phase such as carbon dioxide is used, proves to be an excellent technique for fast and efficient separations, especially when sub-2μm particles are used. However, to achieve high velocities when using these small particles, and in order to stay within the flow rate range of current SFC-instruments, narrow columns (e.g. 2.1mm ID) must be used. Unfortunately, state-of-the-art instrumentation is limiting the full separation power of these narrower columns due to significant extra-column band broadening effects. The present work identifies and quantifies the different contributions to extra-column band broadening in SFC such as the influence of the sample solvent, injection volume, extra-column volumes and detector cell volume/design. When matching the sample solvent to the mobile phase in terms of elution strength and polarity (e.g. using hexane/ethanol/isopropanol 85/10/5vol%) and lowering the injection volume to 0.4μL, the plate count can be increased from 7600 to 21,300 for a low-retaining compound (k'=2.3) on a 2.1mm×150mm column (packed with 1.8μm particles). The application of a water/acetonitrile mixture as sample solvent was also investigated. It was found that when the volumetric ratio of water/acetonitrile was optimized, only a slightly lower plate count was measured compared to the hexane-based solvent when minimizing injection and extra-column volume. This confirms earlier results that water/acetonitrile can be used if water-soluble samples are considered or when a less volatile solvent is preferred. Minimizing the ID of the connection capillaries from 250 to 65μm, however, gives no further improvement in obtained efficiency for early-eluting compounds when a standard system configuration with optimized sample solvent was used. When switching to a state-of-the-art detector design with reduced (dispersion) volume (1.7-0.6μL), an increase in plate count is observed (from 11,000 to 14

  19. Dry-column chromatography of uranium. Application to chemical analysis of monazite and phosphate rock for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Oguma, K; Kuroda, R [Chiba Univ. (Japan). Faculty of Engineering

    1981-08-01

    A dry-column chromatographic technique has been applied to the separation of uranium from complicated matrices. It has been demonstrated that operating parameters of thin-layer chromatography on silanized silica gel in isopropyl ether - tetrahydrofuran - nitric acid (65:20:3) can be transferred to this technique. Chromatograms are thus easily developed on dry packed column with the solvent system of the type used in the TLC. Uranium is eluted off the column and determined with Arsenazo III spectrophotometrically. The technique is successfully applied to the determination of uranium in monazite and phosphate rock samples with good precision and accuracy.

  20. Analysis of trace dicyandiamide in stream water using solid phase extraction and liquid chromatography UV spectrometry.

    Science.gov (United States)

    Qiu, Huidong; Sun, Dongdi; Gunatilake, Sameera R; She, Jinyan; Mlsna, Todd E

    2015-09-01

    An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction. The extraction procedure (including loading, washing, and eluting) used a flow rate of 1.0mL/min, and dicyandiamide was eluted with 20mL of a methanol/acetonitrile mixture (V/V=2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography-ultraviolet spectroscopy (HPLC-UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge (with activated carbon). Separation was achieved on a ZIC(®)-Hydrophilic Interaction Liquid Chromatography (ZIC-HILIC) (50mm×2.1mm, 3.5μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions (R(2)>0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations (RSDs, n=3) were below 6.1% with a detection limit of 5.0ng/mL for stream water samples. Copyright © 2015. Published by Elsevier B.V.

  1. The use of phospholipid modified column for the determination of lipophilic properties in high performance liquid chromatography.

    Science.gov (United States)

    Godard, Tal; Grushka, Eli

    2011-03-04

    A new chromatographic stationary phase obtained by coating a reversed phase amide column with phosphatidylcholine based liposomes solution to yield a phospholipid modified column (PLM). The modification is achieved by the dynamic coating method which recycles the coating solution through the column in a closed loop for a period of 24 h. The chromatographic properties of the new column have changed significantly as compared to the original amide column due to the phospholipid coating. A good correlation was observed between n-octanol/water logP values and the logarithm of the retention factor obtained on the PLM column for a large number of solutes. In addition the PLM column was characterized using the linear solvation energy relationship (LSER). The values of the LSER system constants for the PLM column were calculated and were found to be very close to those of the n-octanol/water extraction system thus suggesting that the PLM column can be used for the estimation of n-octanol/water partition coefficient and serve as a possible alternative to the shake-flask method for lipophilicity determination. In addition, the results suggest that the PLM column can provide an alternative to other phospholipid-based column such as the IAM and the DPC columns. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Application and improvement of reciprocating-sieve plate extraction column in natural uranium extraction and purification process

    International Nuclear Information System (INIS)

    Wang Xuejun; Li Linyan; Liu Jing; Liu Xin; Yang Lifeng; Xiao Shaohua; Liu Hao

    2013-01-01

    Reciprocating-sieve plate extraction column is commonly used in the extraction process. Optimization and application were conducted successfully via production practice in some chemical and pharmaceutical plants, and good results are obtained while it is applied in the natural uranium extraction and purification process. The key component of reciprocating-sieve plate extraction column is gear-drive equipment in which drive motor serves as its core. Hence, it is important to select appropriate mode of speed regulation. In this paper, the principle and performance of several mode of speed regulation are compared. Both electromagnetic slip and frequency speed-regulation can be applied in general industrial process, but frequency speed-regulation with low energy cost can be used in wider operating range. The application of frequency speed-regulation mode used in reciprocating-sieve plate extraction column will increase the convenience and stability of natural uranium extraction and purification process. (authors)

  3. Capillary column switching restricted-access media-liquid chromatography-electrospray ionization-tandem mass spectrometry system for simultaneous and direct analysis of drugs in biofluids.

    Science.gov (United States)

    Santos-Neto, Alvaro J; Markides, Karin E; Sjöberg, Per J R; Bergquist, Jonas; Lancas, Fernando M

    2007-08-15

    Capillary online restricted-access media-liquid chromatography-electrospray ionization-tandem mass spectrometry (RAM-LC-ESI-MS/MS) for direct analysis of drugs and metabolites spiked in biological fluids was developed. Using a column switching setup it was possible to perform effective sample preparation and analysis of raw biological fluids (plasma and urine) without matrix effects in the electrospray mass spectrometric detection step. The peak focusing efficiency of the extraction column was more effective in backflush compared to foreflush mode. The system was able to concentrate diminished samples of polar drugs and their metabolites reaching quantifiable results as low as 1 ng/mL utilizing a sample volume of only 333 nL of biofluids. New column hardware was developed to circumvent clogging problems experienced with plasma injections. The glass fiber filter frit, which is commonly used, was replaced with a short piece of 20 microm i.d. fused silica capillary. The extraction columns were able to handle up to 60 injections and showed a high loading capacity, making the saturation of the MS detector the limiting factor on the linear dynamic range. The simultaneous separation and detection of 10 drugs and metabolites was obtained in 8 min of analysis, including the online sample preparation and enrichment step.

  4. Dynamics and control of a heat pump assisted extractive dividing-wall column for bioethanol dehydration

    NARCIS (Netherlands)

    Patraşcu, Iulian; Bildea, Costin Sorin; Kiss, Anton A.

    Recently, a novel heat-pump-assisted extractive distillation process taking place in a dividing-wall column was proposed for bioethanol dehydration. This integrated design combines three distillation columns into a single unit that allows over 40% energy savings and low specific energy requirements

  5. Analysis of polycyclic aromatic hydrocarbons I. Determination by gas chromatography with glass and fused silica capillary columns

    International Nuclear Information System (INIS)

    Perez, M. M.; Gonzalez, D.

    1987-01-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silica capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (Author) 17 refs

  6. Using Artificial Soil and Dry-Column Flash Chromatography to Simulate Organic Substance Leaching Process: A Colorful Environmental Chemistry Experiment

    Science.gov (United States)

    de Avellar, Isa G. J.; Cotta, Tais A. P. G.; Neder, Amarilis de V. Finageiv

    2012-01-01

    Soil is an important and complex environmental compartment and soil contamination contributes to the pollution of aquifers and other water basins. A simple and low-cost experiment is described in which the mobility of three organic compounds in an artificial soil is examined using dry-column flash chromatography. The compounds were applied on top…

  7. Analysis of polycyclic aromatic hydrocarbons. I. Determination by gas chromatography with glass and fused solica capillary columns

    International Nuclear Information System (INIS)

    Perez Garcia, M.; Gonzalez, D.

    1987-01-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silice capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (author). 3 figs., 17 refs

  8. Boehringer immunoinhibition procedure for creatine kinase-MB evaluated and compared with column ion-exchange chromatography

    NARCIS (Netherlands)

    ter Welle, H. F.; Baartscheer, T.; Fiolet, J. W.

    1983-01-01

    In determination of creatine kinase isoenzyme MB (CK-MB), the Boehringer immunoinhibition method gives a high and variable blank activity as compared with column-chromatography. Thus a correction must be applied. Furthermore, a second correction of 1% of total creatine kinase activity is necessary

  9. Molecularly imprinted coated graphene oxide solid-phase extraction monolithic capillary column for selective extraction and sensitive determination of phloxine B in coffee bean

    International Nuclear Information System (INIS)

    Zhai, Haiyun; Su, Zihao; Chen, Zuanguang; Liu, Zhenping; Yuan, Kaisong; Huang, Lu

    2015-01-01

    Highlights: • A new GO-MISPE monolithic capillary column was prepared. • The column showed ability of impurities removal and excellent selectivity. • Phloxine B existed in real sample was enriched more than 90 times. • The GO-MISPE column presented good recovery and high stability. • The method was prospered to analyze phloxine B and LOD achieved 0.3 ng g −1 . - Abstract: A method was developed to sensitively determine phloxine B in coffee bean by molecularly imprinted polymers (MIPs) coated graphene oxide (GO) solid-phase extraction (GO-MISPE) coupled with high-performance liquid chromatography and laser-induced fluorescence detection (HPLC–LIF). The GO-MISPE capillary monolithic column was prepared by water-bath in situ polymerization, using GO as supporting material, phloxine B, methacrylic acid (MAA), and ethylene dimethacrylate (EDMA) as template, functional monomer, and cross-linker, respectively. The properties of the homemade GO-MISPE capillary monolithic column, including capacity and specificity, were investigated under optimized conditions. The GO-MIPs were characterized by scanning electron microscopy (SEM) and Fourier transform-infrared spectroscopy (FT-IR). The mean recoveries of phloxine B in coffee bean ranged from 89.5% to 91.4% and the intra-day and inter-day relative standard deviation (RSD) values all ranged from 3.6% to 4.7%. Good linearity was obtained over 0.001–2.0 μg mL −1 (r = 0.9995) with the detection limit (S/N = 3) of 0.075 ng mL −1 . Under the selected conditions, enrichment factors of over 90-fold were obtained and extraction on the monolithic column effectively cleaned up the coffee bean matrix. The results demonstrated that the proposed GO-MISPE HPLC–LIF method can be applied to sensitively determine phloxine B in coffee bean

  10. Molecularly imprinted coated graphene oxide solid-phase extraction monolithic capillary column for selective extraction and sensitive determination of phloxine B in coffee bean

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Haiyun, E-mail: zhaihaiyun@126.com [College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou 510006 (China); Su, Zihao [College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou 510006 (China); Chen, Zuanguang, E-mail: chenzg@mail.sysu.edu.cn [School of Pharmaceutical Science, Sun Yat-sen University, Guangzhou 510006 (China); Liu, Zhenping; Yuan, Kaisong; Huang, Lu [College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou 510006 (China)

    2015-03-20

    Highlights: • A new GO-MISPE monolithic capillary column was prepared. • The column showed ability of impurities removal and excellent selectivity. • Phloxine B existed in real sample was enriched more than 90 times. • The GO-MISPE column presented good recovery and high stability. • The method was prospered to analyze phloxine B and LOD achieved 0.3 ng g{sup −1}. - Abstract: A method was developed to sensitively determine phloxine B in coffee bean by molecularly imprinted polymers (MIPs) coated graphene oxide (GO) solid-phase extraction (GO-MISPE) coupled with high-performance liquid chromatography and laser-induced fluorescence detection (HPLC–LIF). The GO-MISPE capillary monolithic column was prepared by water-bath in situ polymerization, using GO as supporting material, phloxine B, methacrylic acid (MAA), and ethylene dimethacrylate (EDMA) as template, functional monomer, and cross-linker, respectively. The properties of the homemade GO-MISPE capillary monolithic column, including capacity and specificity, were investigated under optimized conditions. The GO-MIPs were characterized by scanning electron microscopy (SEM) and Fourier transform-infrared spectroscopy (FT-IR). The mean recoveries of phloxine B in coffee bean ranged from 89.5% to 91.4% and the intra-day and inter-day relative standard deviation (RSD) values all ranged from 3.6% to 4.7%. Good linearity was obtained over 0.001–2.0 μg mL{sup −1} (r = 0.9995) with the detection limit (S/N = 3) of 0.075 ng mL{sup −1}. Under the selected conditions, enrichment factors of over 90-fold were obtained and extraction on the monolithic column effectively cleaned up the coffee bean matrix. The results demonstrated that the proposed GO-MISPE HPLC–LIF method can be applied to sensitively determine phloxine B in coffee bean.

  11. High-capacity cation-exchange column for enhanced resolution of adjacent peaks of cations in ion chromatography.

    Science.gov (United States)

    Rey, M A

    2001-06-22

    One of the advantages of ion chromatography [Anal Chem. 47 (1975) 1801] as compared to other analytical techniques is that several ions may be analyzed simultaneously. One of the most important contributions of cation-exchange chromatography is its sensitivity to ammonium ion, which is difficult to analyze by other techniques [J. Weiss, in: E.L. Johnson (Ed.), Handbook of Ion Chromatography, Dionex, Sunnyvale, CA, USA]. The determination of low concentrations of ammonium ion in the presence of high concentrations of sodium poses a challenge in cation-exchange chromatography [J. Weiss, Ion Chromatography, VCH, 2nd Edition, Weinheim, 1995], as both cations have similar selectivities for the common stationary phases containing either sulfonate or carboxylate functional groups. The task was to develop a new cation-exchange stationary phase (for diverse concentration ratios of adjacent peaks) to overcome limitations experienced in previous trails. Various cation-exchange capacities and column body formats were investigated to optimize this application and others. The advantages and disadvantages of two carboxylic acid columns of different cation-exchange capacities and different column formats will be discussed.

  12. Separation of tungsten from molybdenum by liquid-liquid extraction and extraction chromatography using thiocyanate and a quarternary ammonium salt

    International Nuclear Information System (INIS)

    Yonezawa, C.; Onishi, H.

    1977-01-01

    Methods were developed for the separation of tungsten from molybdenum by liquid-liquid extraction and extraction chromatography using thiocyanate and a quaternary ammonium salt, Zephiramine. Tungsten was extracted into chloroform as an ion associate of tungsten(V)-thiocyanate complex and Zephiramine cation was retained on a column of Teflon powder coated with Zephiramine, but molybdenum(III) was neither extracted nor retained. The extraction chromatographic method was succesfully applied to the determination of trace amounts of tungsten in molybdenum by neutron activation analysis. The γ-ray spectrum, observed with the Ge(Li) detector, of tungsten fraction separated from irradiated molybdenum are shown. The peaks of 99 Mo, sup(99m)Tc, and sup(99m)Nb (produced by 92 Mo(n,p)sup(99m)Nb) were seen, but these nuclides did nit interfere with the determination of tungsten using a NaI(Tl) detector. The results of the neutron activation analysis of a sample of ammonium molybdate agreed quite well with that of the spectrophotometric determination after extraction chromatographic separation. (T.G.)

  13. Determination of phthalate esters in physiological saline solution by monolithic silica spin column extraction method

    Directory of Open Access Journals (Sweden)

    Lu Lu

    2011-05-01

    Full Text Available Monolithic silica spin column extraction (MonoSpin-SPE was developed as a simple, sensitive, and eco-friendly pretreatment method which combined with ultra-fast liquid chromatography-mass spectrometry (UFLC-MS to determine the levels of six phthalate esters, dimethyl-(DMP, diethyl-(DEP, dipropyl- [DPrP], butyl-benzyl-(BBP, dicyclohexyl(DcHP, and di- n-octyl-(DOP phthalate in physiological saline samples. Under optimized experimental conditions, the method was linear in the following ranges: 0.2- 50 μ/L for DMP, DEP, DPrP, DcHP and DOP; 5 – 100 μ/L for BBP. The correlation coefficients (R2 were in the range of O. 9951 – O. 9995 for all the analytes and the limits of detection (LODs and limits of quantification (LOQs were in the ranges of 0.02 – 0.9 μ/L and 0.08 – 2.7 μ/L, respectively. The pretreatment process showed good reproducibility with inter-day and intra-day relative standard deviations (RSDs below 8.5% and 11.2%, respectively. This method was used to determine the levels of six phthalate esters in physiological saline samples and the recoveries ranged from 71.2% to 107. 3%. DMP and DEP were found in actual physical saline samples (brand A and brand B. Keywords: Monolithic silica spin column, Phthalate esters, Physiological saline samples, Ultra fast liquid chromatographymass spectrometry (UFLC-MS

  14. Chromatography, solid-phase extraction, and capillary electrochromatography with MIPs.

    Science.gov (United States)

    Tóth, Blanka; Horvai, George

    2012-01-01

    Most analytical applications of molecularly imprinted polymers are based on their selective adsorption properties towards the template or its analogs. In chromatography, solid phase extraction and electrochromatography this adsorption is a dynamic process. The dynamic process combined with the nonlinear adsorption isotherm of the polymers and other factors results in complications which have limited the success of imprinted polymers. This chapter explains these problems and shows many examples of successful applications overcoming or avoiding the problems.

  15. Evaluation of reversible interconversion in comprehensive two-dimensional gas chromatography using enantioselective columns in first and second dimensions.

    Science.gov (United States)

    Kröger, Sabrina; Wong, Yong Foo; Chin, Sung-Tong; Grant, Jacob; Lupton, David; Marriott, Philip J

    2015-07-24

    The reversible molecular interconversion behaviour of a synthesised oxime (2-phenylpropanaldehyde oxime; (C6H5)CH(CH3)CHN(OH)) was investigated by both, single dimensional gas chromatography (1D GC) and comprehensive two-dimensional gas chromatography (GC×GC). Previous studies on small molecular weight oximes were extended to this larger aromatic oxime (molar mass 149.19gmol(-1)) with interest in the extent of interconversion, enantioselective resolution, and retention time. On a polyethylene glycol (PEG; wax-type) column, a characteristic interconversion zone between two antipodes of E and Z isomers was formed by molecules which have undergone isomerisation on the column (E⇌Z). The extent of interconversion was investigated by varying chromatographic conditions (oven temperature and carrier flow rate) to understand the nature of the behaviour observed. The extent of interconversion was negligible in both enantioselective and methyl-phenylpolysiloxane phase-columns, correlating with the low polarity of the stationary phase. In order to obtain isomerisation along with enantio-resolution, a wax-type and an enantioselective column were coupled in either enantioselective-wax or wax-enantioselective order. The most appropriate column arrangement was selected for study by using a GC×GC experiment with either a wax-phase or phenyl-methylpolysiloxane phase as (2)D column. In addition to evaluation of these fast elution columns, a long narrow-bore enantioselective column (10m) was introduced as (2)D, providing an enantioselective-PEG (coupled-column ensemble: (1)D1+(1)D2)×enantioselective ((2)D) column combination. In this instance, the (1)D1 enantioselective column provides enantiomeric separation of the corresponding enantiomers ((R) and (S)) of (E)- and (Z)-2-phenylpropanaldehyde oxime, followed by E/Z isomerisation in the coupled (1)D2 PEG (reactor) column. The resulting chromatographic interconversion region was modulated and separated into either E/Z isomers

  16. Survey of simulation methods for modeling pulsed sieve-plate extraction columns

    International Nuclear Information System (INIS)

    Burkhart, L.

    1979-03-01

    The report first considers briefly the use of liquid-liquid extraction in nuclear fuel reprocessing and then describes the operation of the pulse column. Currently available simulation models of the column are reviewed, and followed by an analysis of the information presently available from which the necessary parameters can be obtained for use in a model of the column. Finally, overall conclusions are given regarding the information needed to develop an accurate model of the column for materials accountability in fuel reprocessing plants. 156 references

  17. Micro-fabricated semi-packed column for gas chromatography by using functionalized parylene as a stationary phase

    International Nuclear Information System (INIS)

    Nakai, T; Nishiyama, S; Shuzo, M; Delaunay, J-J; Yamada, I

    2009-01-01

    The conformal coating of effective stationary phases onto micro-fabricated columns having complex geometries such as semi-packed columns poses a real challenge. Here, we report for the first time the conformal coating of a semi-packed column with amino-functionalized parylene diX-AM (poly-aminomethyl-[2,2]-paracyclophane), which was found to be an effective stationary-phase material for the chromatography of short-retention-time compounds. A semi-packed column (consisting of a zigzag array of 30 µm square micro-pillars in a 1.0 m long, 180 µm wide and 230 µm deep channel) and an open tubular column (1.0 m long, 160 µm wide and 230 µm deep channel) used for comparison purposes were micro-fabricated on silicon that was subsequently coated with diX-AM parylene and thermally bonded. The chromatograms recorded on a commercial gas chromatograph demonstrated the usefulness of the conformal diX-AM coating as a stationary phase for semi-packed columns. The separation efficiency of the semi-packed column was found to be more than ten times that of the open tubular column

  18. Effects of liquid post-column addition in electrospray ionization performance in supercritical fluid chromatography-mass spectrometry.

    Science.gov (United States)

    Akbal, Laura; Hopfgartner, Gérard

    2017-09-29

    In supercritical fluid chromatography coupled to atmospheric pressure ionization mass spectrometry (SFC-MS), the use of a make-up post-column is almost mandatory to avoid analyte precipitation, especially when using low percentage of modifier (supercritical conditions (1mL/min 40°C, 150bar) to gaseous state (room temperature, atmospheric pressure), the CO 2 expands around 430 times, contributing to almost 5% of the nebulizing process. In positive mode, the presence of ammonium ions either in the mobile phase or in the make-up did significantly increase the MS signal, even at basic apparent pH. The ionization performance of electrospray is influenced by the acidic buffer power of the carbon dioxide, and was found to be restricted in the apparent pH range of 3.8-7.2 in the various conditions investigated. This may challenge sensitive detection in negative mode, as illustrated for bosentan. The use of DMSO as make-up additive (up to 30%) showed a simplification of the full scan spectrum regarding the adducts. Finally, the optimization of make-up composition leads to an enhancement up to a factor of 69 on the electrospray MS response signal, for the SFC-SRM/MS analysis of HIV protease inhibitors in plasma extracted from Dried Plasma Spots. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Laboratory studies of the behavior of undissolved solids in both pulsed and packed column extraction systems

    International Nuclear Information System (INIS)

    Siemer, D.D.

    1989-01-01

    A substantial fraction of the finely divided undissolved solid material found in nuclear fuel reprocessing dissolver-product solutions is hydrophobic and tends to ''seek'' any organic-aqueous interface existing within countercurrent liquid-liquid extraction systems. While passing through pulsed-type columns this material is swept out of the aqueous phase by the combined surface area of the tiny bubbles of dispersed phase. Because these bubbles have a net velocity towards the end of the column where the nominal interface is located, the solids are swept in that direction too. These solids tend to gather in a three-phase ''crud'' layer at the nominal interface point. At equilibrium, about the same amount breaks off from the crud layer and escapes into the liquid exiting from that end of the column as enters it from the other side. If large enough, the crud layer can even interfere with interface detection and control equipment. In packed-column extraction systems, an additional problem is that feed solids can accumulate within the packing material to the point that the column '' floods'' or even totally plugs. The keys to preventing solids-related problems is the correct choice of interface level, and with packed columns, the addition of a ''pulsing leg'' at the bottom of the column. Pulsing packed column systems not only prevents solids from settling onto packing material but it also increses the number of theoretical stages available for extraction. 3 figs., 2 tabs

  20. Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Wu Shuchao [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Xu Wei [State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310028, Zhejiang (China); Yang Bingcheng [School of Pharmacy, East China University of Science and Technology, Shanghai 200237 (China); Ye Mingli [Thermofisher scientific (China), Shanghai 201203 (China); Zhang Peimin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Shentu Chao [College of Biology and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015 (China); Zhu Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China)

    2012-07-20

    Highlight: Black-Right-Pointing-Pointer An electrolytic cell including ruthenium modified titanium electrode was fabricated. Black-Right-Pointing-Pointer Ion chromatography/electrochemical derivatization/fluorescence detection was developed. Black-Right-Pointing-Pointer Strong oxidation capacity of this EC was obtained by using the Ru/Ti electrode with large surface area. - Abstract: An electrolytic cell (EC), composed of two ruthenium-plated titanium electrodes separated by cation-exchange membranes, was fabricated and evaluated for online postcolumn derivatization in ion chromatography (IC). Folic acid (FA) and methotrexate (MTX) were preliminarily used as prototype analytes to test the performance of EC. After separation by an anion exchange column, FA and MTX, which emit very weak fluorescence when excited, were electrochemically oxidized online in the anode chamber of the EC. The compounds with strong fluorescence, which are oxidation products, were detected by the fluorescence detector. The phosphate buffer solution (100 mM KH{sub 2}PO{sub 4}) served as an optimal eluent for anion exchange chromatographic separation and a suitable supporting electrolyte for electro-oxidation, leading to ideal compatibility between IC separation and the postcolumn electrochemical derivatization. For the presently proposed method, the linear ranges were from 0.01 mg L{sup -1} to 5 mg L{sup -1} for both FA and MTX. The detection limits of FA and MTX were 1.8 and 2.1 {mu}g L{sup -1}, and the relative standard deviations (RSD, n = 7) were 2.9% and 3.6%, respectively. The method was applied for the simultaneous determination of FA and MTX in the plasma of patients being treated for rheumatoid arthritis. The determination of MTX in the urine of the patients of diffuse large B cell lymphoma was also demonstrated.

  1. Rapid analysis of carbohydrates in aqueous extracts and hydrolysates of biomass using a carbonate-modified anion-exchange column.

    Science.gov (United States)

    Sevcik, Richard S; Mowery, Richard A; Becker, Christopher; Chambliss, C Kevin

    2011-03-04

    Quantitative liquid-chromatography techniques used to characterize carbohydrates present in biomass samples can suffer from long analysis times, limited analyte resolution, poor stability, or a combination of these factors. The current manuscript details a novel procedure enabling resolution of glucose, xylose, arabinose, galactose, mannose, fructose, and sucrose via isocratic elution in less than 5 min. Equivalent conditions also enable analysis of cellobiose and maltose with a minimal increase in chromatographic run time (ca. 3 and 6 min, respectively). Noted chromatographic performance requires that a commercially available anion-exchange column be modified with carbonate prior to analysis. Analytical performance of a modified column was assessed over a 5-day period via repeated analyses of 4 samples, resulting from aqueous extraction or quantitative saccharification of a potential biofuel feedstock (i.e., corn stover or switchgrass). A simple solid phase extraction procedure was utilized to clean up each sample prior to analysis. Analytical accuracy of the extraction protocol was assessed by evaluation of matrix spike recoveries which typically ranged from 84% to 98%. The instrumental variability of measured concentrations in real samples over the 5-day period was generally less than 5% RSD for all detected analytes, independent of sample type. Finally, it is important to note that the modified column exhibited exceptional stability over approximately 800 injections of biofeedstock-based samples. These data demonstrate that a carbonate-modified anion-exchange column can be employed for rapid determination of carbohydrates in biomass samples of lignocellulosic origin. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Cation-selective extraction column study for the conception of nuclear medical radionuclide generators

    International Nuclear Information System (INIS)

    Streng, Roman

    2012-01-01

    The topic of the present work is the conception of a Yttrium-90 radionuclide generator for nuclear medicine applications. Due to its physical properties Yttrium-90 is considered as one of the most useful nuclides for radiotherapeutic cancer treatment. The parent nuclide Strontium-90 is gained during reprocessing of fission products. Thus, the sustained availability of large quantities of Yttrium-90 is limited to a number of research facilities. A radionuclide generator provides an independent Yttrium-90 source and enhances the capacities for radiopharmaceutical research and biomedical applications. The present work focussed on the identification of appropriate column materials for the separation of Strontium and Yttrium. The results for two materials are reported: AnaLig registered Sr-01 and crystalline antimonic acid. Based on the mode of operation of the Technetium-99m generator the aim was to enable the construction of a compact, enclosed apparatus. The projected device comprises a reservoir for the eluant, the ion-exchange column, pipings and radiation shielding. Elution of Yttrium-90 could then be easily performed by connecting evacuated vials to the outlet tube. The prospected concept involves physical and chemical confinements that exclude most of the known processes for Strontium-Yttrium separation. For example no ligands, no oxidizing reactants (e.g. nitric acid) and no organic solvents are to be used, but small volumes of isotonic or buffer solutions and dilute acids respectively. AnaLig registered Sr-01 is a commercially available resin used in extraction chromatography. Its high selectivity for Strontium cations results from the strictly defined cavity of the imbedded cryptand. Determination of weight distribution coefficients, elution studies and pre-generator experiments were carried out. Quantitative separation of Yttrium from Strontium and Zirconium is possible using small volumes of 0,05 M hydrochloric acid as eluant. Furthermore, high flow rates

  3. Bone protein extraction without demineralization using principles from hydroxyapatite chromatography.

    Science.gov (United States)

    Cleland, Timothy P; Vashishth, Deepak

    2015-03-01

    Historically, extraction of bone proteins has relied on the use of demineralization to better retrieve proteins from the extracellular matrix; however, demineralization can be a slow process that restricts subsequent analysis of the samples. Here, we developed a novel protein extraction method that does not use demineralization but instead uses a methodology from hydroxyapatite chromatography where high concentrations of ammonium phosphate and ammonium bicarbonate are used to extract bone proteins. We report that this method has a higher yield than those with previously published small-scale extant bone extractions, with and without demineralization. Furthermore, after digestion with trypsin and subsequent high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) analysis, we were able to detect several extracellular matrix and vascular proteins in addition to collagen I and osteocalcin. Our new method has the potential to isolate proteins within a short period (4h) and provide information about bone proteins that may be lost during demineralization or with the use of denaturing agents. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. High-performance liquid chromatography separation of unsaturated organic compounds by a monolithic silica column embedded with silver nanoparticles.

    Science.gov (United States)

    Zhu, Yang; Morisato, Kei; Hasegawa, George; Moitra, Nirmalya; Kiyomura, Tsutomu; Kurata, Hiroki; Kanamori, Kazuyoshi; Nakanishi, Kazuki

    2015-08-01

    The optimization of a porous structure to ensure good separation performances is always a significant issue in high-performance liquid chromatography column design. Recently we reported the homogeneous embedment of Ag nanoparticles in periodic mesoporous silica monolith and the application of such Ag nanoparticles embedded silica monolith for the high-performance liquid chromatography separation of polyaromatic hydrocarbons. However, the separation performance remains to be improved and the retention mechanism as compared with the Ag ion high-performance liquid chromatography technique still needs to be clarified. In this research, Ag nanoparticles were introduced into a macro/mesoporous silica monolith with optimized pore parameters for high-performance liquid chromatography separations. Baseline separation of benzene, naphthalene, anthracene, and pyrene was achieved with the theoretical plate number for analyte naphthalene as 36,000 m(-1). Its separation function was further extended to cis/trans isomers of aromatic compounds where cis/trans stilbenes were chosen as a benchmark. Good separation of cis/trans-stilbene with separation factor as 7 and theoretical plate number as 76,000 m(-1) for cis-stilbene was obtained. The trans isomer, however, is retained more strongly, which contradicts the long- established retention rule of Ag ion chromatography. Such behavior of Ag nanoparticles embedded in a silica column can be attributed to the differences in the molecular geometric configuration of cis/trans stilbenes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Polar and nonpolar organic polymer-based monolithic columns for capillary electrochromatography and high-performance liquid chromatography.

    Science.gov (United States)

    Rathnasekara, Renuka; Khadka, Shantipriya; Jonnada, Murthy; El Rassi, Ziad

    2017-01-01

    This review article is a continuation of the previous reviews on the area of monolithic columns covering the progress made in the field over the last couple of years from the beginning of the second half of 2014 until the end of the first half of 2016. It summarizes and evaluates the evolvement of both polar and nonpolar organic monolithic columns and their use in hydrophilic interaction LC and CEC and reversed-phase chromatography and RP-CEC. The review article discusses the results reported in a total of 62 references. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Using the hydrophobic subtraction model to choose orthogonal columns for online comprehensive two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune; Nielsen, Nikoline Juul; Christensen, Jan H.

    2014-01-01

    A method for choosing orthogonal columns for a specific sample set in on-line comprehensive two-dimensional liquid chromatography (LC×LC) was developed on the basis of the hydrophobic subtraction model. The method takes into account the properties of the sample analytes by estimating new F...... neutral and 4 acidic oxygenated polycyclic aromatic compounds (PACs) and 3 nitrogen-containing PAC bases was measured isocratically on 12 columns. The isocratic runs were used to determine the hydrophobic subtraction model analyte parameters, and these were used to estimate new F-weights and predict...

  7. Analysis of polycyclic aromatic hydrocarbons in vegetable oils combining gel permeation chromatography with solid-phase extraction clean-up

    DEFF Research Database (Denmark)

    Fromberg, Arvid; Højgård, A.; Duedahl-Olesen, Lene

    2007-01-01

    system equipped with a GPC column (S-X3) and pre-packed silica SPE columns for the subsequent clean-up and finally gas chromatography-mass spectrometry (GC-MS) determination. The method was validated for the determination of PAHs in vegetable oils and it can meet the criteria for the official control...... of benzo[a]pyrene levels in foods laid down by the Commission of the European Communities. A survey of 69 vegetable oils sampled from the Danish market included olive oil as well as other vegetable oils such as rapeseed oil, sunflower oil, grape seed oil and sesame oil. Levels of benzo[a]pyrene in all......A semi-automatic method for the determination of polycyclic aromatic hydrocarbons (PAHs) in edible oils using a combined gel permeation chromatography/solid-phase extraction (GPC/SPE) clean-up is presented. The method takes advantage of automatic injections using a Gilson ASPEC XL sample handling...

  8. Use of cyanopropyl-bonded hplc column for bioassay-directed fractionation of organic extracts from incinerator emissions

    International Nuclear Information System (INIS)

    DeMarini, D.M.; Williams, R.W.; Brooks, L.R.; Taylor, M.S.

    1992-01-01

    The present study has shown that cyanopropyl-(CN) bonded silica HPLC columns are applicable for the fractionation of mass and mutagenic activity of organic extracts from some incinerator emissions. Dichloromethane-extractable organics from particles emitted by two different municipal waste incinerators and by a pilot-scale rotary kiln incinerator that was combusting polyethylene were fractionated by HPLC, and the mutagenicity of the fractions was determined by means of a microsuspension mutagenicity assay with Salmonella TA98. The CN-bonded silica columns provided high (80-100 percent) mass and mutagenicity recoveries for most emission extracts, and it fractionated the mutagenic activity. The results suggest that the emissions from municipal waste incinerators contain a high amount of direct-acting (-S9) mutagenic activity that is resolvable by HPLC using CN-bonded silica. Sub-fractionation of selected mutagenic HPLC fractions and subsequent analysis by gas chromatography/mass spectroscopy can be used to identify mutagenic species within complex incinerator emissions. The coupling of microsuspension bioassays to HPLC fractionation should be a useful tool for this type of analysis

  9. Technology of extraction by solvent in pulsed columns

    International Nuclear Information System (INIS)

    Ros, P.

    1992-01-01

    Since its creation, the CEA (Commissariat a l'energie atomique) has produced several separation processes for natural or enriched uranium treatment and the treatment of spent fuels coming from nuclear reactors. Among these technologies, extraction by solvent is broadly used for separation and purification of nuclear matters. This technology can be used for other applications as hydrometallurgy, chemistry, pharmaceutics, depollution, agro-industry

  10. Determination of polycyclic aromatic hydrocarbons in palm oil mill effluent by soxhlet extraction and gas chromatography-flame ionization detector

    International Nuclear Information System (INIS)

    Nor Fairolzukry Ahmad Rasdy; Mohd Marsin Sanagi; Wan Aini Wan Ibrahim; Ahmedy Abu Naim

    2008-01-01

    A method has been developed for the determination of polycyclic aromatic hydrocarbons (PAHs) from palm oil mill effluent based on gas chromatography-flame ionization detection. Extraction of spiked PAHs (napthalene, fluorene phenanthrene, fluoranthene and pyrene) in palm oil waste was carried out by Soxhlet extraction using hexane-dichloromethane (60:40 v/v) as the solvent. Excellent separations were achieved using temperature programmed GC on Ultra-1 fused-silica capillary column (30 m x 250 μm ID), carrier gas helium at a flow rate of 1 mL/ min. (author)

  11. Determination of Imidacloprid and metabolites by liquid chromatography with an electrochemical detector and post column photochemical reactor

    Energy Technology Data Exchange (ETDEWEB)

    Rancan, M. [Consiglio per la Ricerca e la Sperimentazione in Agricoltura (CRA), Istituto Nazionale di Apicoltura, Via di Saliceto 80, I-40128 Bologna (Italy)]. E-mail: mrancan@inapicoltura.org; Sabatini, A.G. [Consiglio per la Ricerca e la Sperimentazione in Agricoltura (CRA), Istituto Nazionale di Apicoltura, Via di Saliceto 80, I-40128 Bologna (Italy); Achilli, G. [Euroservice s.r.l., Piazza Maggiolini 3A, I-20015 Parabiago, Milan (Italy); Galletti, G.C. [Dipartimento di Chimica ' G.Ciamician' , University of Bologna, Via F. Selmi 2, I-40126 Bologna (Italy)

    2006-01-05

    A procedure for the determination of Imidacloprid and its main metabolites was set up by means of liquid chromatography with an electrochemical detector and post-column photochemical reactor (LC-h{nu}-ED). Sample clean-up was developed for bees, filter paper and maize leaves. Chromatographic conditions were based on a reversed-phase C-18 column operated by phosphate buffer 50 mM/CH{sub 3}CN (80/20, v/v) at pH 2.9. Detection of Imidacloprid and its metabolites was performed at a potential of 800 mV after photoactivation at 254 nm. Compared to conventional techniques such as gas chromatography/mass spectrometry (GC/MS) or LC coupled to other detectors, the present method allows simultaneous trace-level determination of both Imidacloprid (0.6 ng ml{sup -1}) and its main metabolites (2.4 ng ml{sup -1})

  12. Determination of Imidacloprid and metabolites by liquid chromatography with an electrochemical detector and post column photochemical reactor

    International Nuclear Information System (INIS)

    Rancan, M.; Sabatini, A.G.; Achilli, G.; Galletti, G.C.

    2006-01-01

    A procedure for the determination of Imidacloprid and its main metabolites was set up by means of liquid chromatography with an electrochemical detector and post-column photochemical reactor (LC-hν-ED). Sample clean-up was developed for bees, filter paper and maize leaves. Chromatographic conditions were based on a reversed-phase C-18 column operated by phosphate buffer 50 mM/CH 3 CN (80/20, v/v) at pH 2.9. Detection of Imidacloprid and its metabolites was performed at a potential of 800 mV after photoactivation at 254 nm. Compared to conventional techniques such as gas chromatography/mass spectrometry (GC/MS) or LC coupled to other detectors, the present method allows simultaneous trace-level determination of both Imidacloprid (0.6 ng ml -1 ) and its main metabolites (2.4 ng ml -1 )

  13. Application of a simple column-switching ion chromatography technique for removal of matrix interferences and sensitive fluorescence determination of acidic compounds (pharmaceutical drugs) in complex samples.

    Science.gov (United States)

    Muhammad, Nadeem; Subhani, Qamar; Wang, Fenglian; Guo, Dandan; Zhao, Qiming; Wu, Shuchao; Zhu, Yan

    2017-09-15

    This work illustrates the introduction of a simple, rugged and flexible column-switching ion chromatography (IC) technique for an automated on-line QuEChERS extracted samples extracts washing followed by sensitive fluorescence (FLD) determination of five acidic pharmaceutical drugs namely; clofibric acid (CLO), ibuprofen (IBU), aspirin (ASP), naproxen (NAP) and flurobrofen (FLU) in three complex samples (spinach, apple and hospital sewage sludge). An old anion exchange column IonPac ® AS11-HC was utilized as a pre-treatment column for on-line washing of inorganic and organic interferences followed by isocratic separation of five acidic drugs with another anion exchange IonPac ® AS12A analytical column by exploiting the column-switching technique. This novel method exhibited good linearity with correlation coefficients (r 2 ) for all drugs were in the range 0.976-0.996. The limit of detection and quantification of all five acidic drugs were in the range 0.024μg/kg to 8.70μg/kg and 0.082μg/kg to 0.029mg/kg, respectively, and better recoveries in the range 81.17-112.5% with percentage relative standard deviations (RSDs) less than 17.8% were obtained. This on-line sample pre-treatment method showed minimum matrix effect in the range of 0.87-1.25 except for aspirin. This simple rugged and flexible column-switching system required only 28min for maximum elimination of matrices and interferences in three complex samples extracts, isocratic separation of five acidic drugs and for the continuous regeneration of pre-treatment column prior to every subsequent analysis. Finally, this simple automated IC system was appeared so rugged and flexible, which can eliminate and wash out most of interference, impurities and matrices in complex samples, simply by adjusting the NaOH and acetonitrile concentration in washing mobile phase with maximum recoveries of acidic analytes of interest. Copyright © 2017. Published by Elsevier B.V.

  14. Experimental investigation of liquid chromatography columns by means of computed tomography

    DEFF Research Database (Denmark)

    Astrath, D.U.; Lottes, F.; Vu, Duc Thuong

    2007-01-01

    The efficiency of packed chromatographic columns was investigated experimentally by means of computed tomography (CT) techniques. The measurements were carried out by monitoring tracer fronts in situ inside the chromatographic columns. The experimental results were fitted using the equilibrium di...

  15. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Dynamics and control of a heat pump assisted extractive dividing-wall column for bioethanol dehydration

    OpenAIRE

    Patraşcu, Iulian; Bildea, Costin Sorin; Kiss, Anton A.

    2017-01-01

    Recently, a novel heat-pump-assisted extractive distillation process taking place in a dividing-wall column was proposed for bioethanol dehydration. This integrated design combines three distillation columns into a single unit that allows over 40% energy savings and low specific energy requirements of 1.24 kWh/kg ethanol. However, these economic benefits are possible only if this highly integrated system is also controllable to ensure operational availability. This paper is the first to addre...

  17. Design of two-column batch-to-batch recirculation to enhance performance in ion-exchange chromatography.

    Science.gov (United States)

    Persson, Oliver; Andersson, Niklas; Nilsson, Bernt

    2018-01-05

    Preparative liquid chromatography is a separation technique widely used in the manufacturing of fine chemicals and pharmaceuticals. A major drawback of traditional single-column batch chromatography step is the trade-off between product purity and process performance. Recirculation of impure product can be utilized to make the trade-off more favorable. The aim of the present study was to investigate the usage of a two-column batch-to-batch recirculation process step to increase the performance compared to single-column batch chromatography at a high purity requirement. The separation of a ternary protein mixture on ion-exchange chromatography columns was used to evaluate the proposed process. The investigation used modelling and simulation of the process step, experimental validation and optimization of the simulated process. In the presented case the yield increases from 45.4% to 93.6% and the productivity increases 3.4 times compared to the performance of a batch run for a nominal case. A rapid concentration build-up product can be seen during the first cycles, before the process reaches a cyclic steady-state with reoccurring concentration profiles. The optimization of the simulation model predicts that the recirculated salt can be used as a flying start of the elution, which would enhance the process performance. The proposed process is more complex than a batch process, but may improve the separation performance, especially while operating at cyclic steady-state. The recirculation of impure fractions reduces the product losses and ensures separation of product to a high degree of purity. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Radial heterogeneity of some analytical columns used in high-performance liquid chromatography.

    Science.gov (United States)

    Abia, Jude A; Mriziq, Khaled S; Guiochon, Georges A

    2009-04-10

    An on-column electrochemical microdetector was used to determine accurately the radial distribution of the mobile phase velocity and of the column efficiency at the exit of three common analytical columns, namely a 100 mm x 4.6mm C18 bonded silica-based monolithic column, a 150 mm x 4.6mm column packed with 2.7 microm porous shell particles of C18 bonded silica (HALO), and a 150 mm x 4.6mm column packed with 3 microm fully porous C18 bonded silica particles (LUNA). The results obtained demonstrate that all three columns are not radially homogeneous. In all three cases, the efficiency was found to be lower in the wall region of the column than in its core region (the central core with a radius of 1/3 the column inner radius). The decrease in local efficiency from the core to the wall regions was lower in the case of the monolith (ca. 25%) than in that of the two particle-packed columns (ca. 35-50%). The mobile phase velocity was found to be ca. 1.5% higher in the wall than in the core region of the monolithic column while, in contrast, it was ca. 2.5-4.0% lower in the wall region for the two particle-packed columns.

  19. Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS).

    Science.gov (United States)

    Boczkaj, Grzegorz; Kamiński, Marian

    2013-10-01

    Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantageous when gas chromatography is used for simulated distillation. This paper presents results from further research on the separation properties of empty fused silica tubing. The efficiency of this chromatographic system has been examined. The usefulness of such conditions has been studied for simulated distillation, i.e. to determine the boiling-point distribution of complex mixtures, mainly petroleum fractions and products, on the basis of their retention relative to reference substances. The results obtained by use of empty-column gas chromatography (EC-GC) and by use of classical simulated distillation columns have been compared for solutes of different polarity. Studies revealed boiling points determined by EC-GC were more accurate than those obtained by the standard method of simulated distillation.

  20. Home-made online hyphenation of pressurized liquid extraction, turbulent flow chromatography, and high performance liquid chromatography, Cistanche deserticola as a case study.

    Science.gov (United States)

    Song, Qingqing; Li, Jun; Liu, Xiao; Zhang, Yuan; Guo, Liping; Jiang, Yong; Song, Yuelin; Tu, Pengfei

    2016-03-18

    Incompatibility between the conventional pressurized liquid extraction (PLE) devices and high performance liquid chromatography (HPLC) extensively hinders direct and green chemical analysis of herbal materials. Herein, a facile PLE module was configured, and then it was online hyphenated with HPLC via a turbulent flow chromatography (TFC) column. Regarding PLE module, a long PEEK tube (0.13 × 1000 mm) was employed to generate desired pressure (approximately 13.0 MPa) when warm acidic water (70 °C) was delivered as extraction solvent at a high flow rate (2.5 mL/min), and a hollow guard column (3.0 × 4.0 mm) was implemented to hold crude materials. Effluent was collected from the outlet of PEEK tube, concentrated, and subjected onto HPLC coupled with hybrid ion trap-time of flight mass spectrometer to assess the extraction efficiency and also to profile the chemical composition of Cistanche deserticola (CD) that is honored as "Ginseng of the desert". Afterwards, a TFC column was introduced to accomplish online transmission of low molecule weight components from PLE module to HPLC coupled with diode array detection, and two electronic 6-port/2-channel valves were in charge of alternating the whole system between extraction (0-3.0 min) and elution (3.0-35.0 min) phases. Quantitative method was developed and validated for simultaneous determination of eight primary phenylethanoid glycosides in CD using online PLE-TFC-HPLC. All findings demonstrated that the home-made platform is advantageous at direct chemical analysis, as well as time-, solvent-, and material-savings, suggesting a robust tool for chemical fingerprinting of herbs. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Comparative investigation of the gel chromatography column scanning method for quality control of /sup 99/sup(m)Tc-methylenediphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Darte, L

    1981-04-01

    Gel chromatography column scanning (GCS) is the method of choice for quality control of sup(99m)Tc-MDP preparations. Using this method all the labelled components are obtained rapidly in one simple test procedure. The influence of various parameters such as gel type, column size, prehistory of column, equilibration, eluent, elution volume and flow rate upon the results have been investigated. Test results for sup(99 m)Tc-MDP have been compared for several different GCS systems, a few TLC systems and column chromatography with fraction collection. The GCS technique, optimized for testing sup(99m)Tc-MDP preparations has been applied in a few experiments in which very good reproducibility is required: Labelling kinetics and stability when stored at room temperature or in a refrigerator and influence of the sup(99m)Te/(sup(99m)Tc + /sup 99/Tc) atomic ratio and of the amount of radioactivity on the sup(99m)Tc-MDP labelling yield, covering parameter ranges of clinical interest, have been studied.

  2. Actinides analysis in emergency situation by on-line coupling between a calix[6]arene-based chromatography column and an Inductively Coupled Plasma-Mass Spectrometer

    International Nuclear Information System (INIS)

    Baghdadi, Sarah

    2015-01-01

    In the event of a nuclear crisis, involving actinides (U, Pu, Am) it is important to have fast analysis methods available in order to identify people that could be contaminated. Usually, they are performed in urine or faeces. Even though, analytical methods used with alpha detection are reliable they are lengthy and tedious to set up. This work consisted in developing an on-line coupling method between a calix[6]arene-based chromatography column and an inductively coupled plasma mass spectrometer (ICP-MS). To do so, a speciation study of actinides in mineralised urine was developed to understand the chemical equilibria happening during the actinides extraction. A protocol was elaborated to extract simultaneously all three actinides at pH = 5, then co-elute them with 0.25 mol.L -1 H 3 PO 4 . Recovery was 56 %, 74 % and 85 % for U, Pu and Am respectively. The column was then coupled to the ICP-MS. A parameter study helped defining mineralisation duration, extraction and elution flow-rates. It was then possible to propose an on-line coupling system allowing reaching detection limits lower than 0.5 mBq.L-1 for 238 U and 243 Am and lower than 5 mBq.L -1 for 239 Pu and 241 Am, for analysis duration lower than 6 hours. These analytical performances show the interest of this technique for a use in a nuclear crisis situation. (author)

  3. Size exclusion chromatography for the removal of pigments from extracellular ligninolytic enzyme extracts from decayed wheat straw.

    Science.gov (United States)

    Shukla, Dharmendra; Patel, Bhavesh; Modi, Hasmukh; Vyas, Bharat Rajiv Manuel

    2011-11-01

    Solid-state fermentation of wheat straw was carried out by a native white rot basidiomycete Daedaleopsis flavida strain 5A. Extract prepared from the 12-day decayed wheat straw contained extracellular ligninolytic enzymes like manganese peroxidase (MnP), manganese-independent peroxidase (MIP), lignin peroxidase (LiP) and laccase along with straw-degraded products and pigments. Sephacryl S-200 size exclusion chromatography in 16/100 column was used for the separation of these ligninolytic enzymes and straw-degraded products and pigments. Recovery of pigment-free ligninolytic enzyme activities as protein was 40% of the total proteins loaded and specific LiP activity increased 34 fold after size exclusion chromatography. Thus accurate estimation of LiP by veratryl alcohol oxidation assay was possible only after the removal of interfering pigments. The reproducibility of size exclusion chromatography is adjudged satisfactory from the consistent results obtained after seven repetitive uses of matrices.

  4. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    International Nuclear Information System (INIS)

    Zacharis, Constantinos K.; Tzanavaras, Paraskevas D.

    2013-01-01

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables

  5. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    Energy Technology Data Exchange (ETDEWEB)

    Zacharis, Constantinos K., E-mail: zacharis@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece); Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute (ATEI) of Thessaloniki, 57400 Thessaloniki (Greece); Tzanavaras, Paraskevas D., E-mail: ptzanava@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2013-10-10

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  6. Enantiomeric quantification of (S)-(+)-methamphetamine in urine by an immunoaffinity column and liquid chromatography-electrospray-mass spectrometry

    International Nuclear Information System (INIS)

    Lua, Ahai C.; Sutono, Yenny; Chou, T.-Y.

    2006-01-01

    A method using an immunoaffinity column (IAC) and liquid chromatography-electrospray ionization mass spectrometry (LC/MS) for on-line detecting the presence of MA in the effluent was developed for the quantitative and enantiomeric determination of (S)-(+)-methamphetamine (D-MA) in urine. The IAC was made in our laboratory and utilized in the LC/MS to simultaneously extract and separate enantiomers of MA from urine samples. An aqueous ammonium acetate buffer was used as the mobile phase. Urine samples were spiked with racemic deuterated methamphetamine (MA-d 14 ) as internal standard (IS), filtered through a membrane, and injected into the LC/MS without any further pre-treatment. Protonated molecular ion of MA and MA-d 14 (m/z 150 and 164) were isolated and further fragmented, the respective product ions, m/z 119 and 130, were collected for quantitative determination. This is an improvement of our previous method (A.C. Lua, Tsong-Yung Chou, J. Chromatogr. A 967 (2002) 191). In the previous method, MA was separated with HPLC, the efflux was fractionated and each fraction was either determined with an immunoassay or GC/MS. Monitoring of MA in the efflux is tedious and time consuming. Urine samples spiked with different concentrations of D-MA were measured by this method. A linear relationship exists in the 150-1050 ng/mL range, and the detection limit (defined as signal-to-noise ratio 3) of D-MA was determined to be 18 ng/mL. The linearity of the method for D-MA can be described by the equation (Y = 1.415 x 10 -3 X + 0.034, correlation coefficient: r 2 = 0.999). Within run, accuracy and precision (n = 6, relative error: -7.2 to +4.0% and relative standard deviation: 3.8-9.3%) of the method are fairly good

  7. Enantiomeric quantification of (S)-(+)-methamphetamine in urine by an immunoaffinity column and liquid chromatography-electrospray-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lua, Ahai C. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Sutono, Yenny [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Chou, T.-Y. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China)]. E-mail: cty@mail.tcu.edu.tw

    2006-08-18

    A method using an immunoaffinity column (IAC) and liquid chromatography-electrospray ionization mass spectrometry (LC/MS) for on-line detecting the presence of MA in the effluent was developed for the quantitative and enantiomeric determination of (S)-(+)-methamphetamine (D-MA) in urine. The IAC was made in our laboratory and utilized in the LC/MS to simultaneously extract and separate enantiomers of MA from urine samples. An aqueous ammonium acetate buffer was used as the mobile phase. Urine samples were spiked with racemic deuterated methamphetamine (MA-d{sub 14}) as internal standard (IS), filtered through a membrane, and injected into the LC/MS without any further pre-treatment. Protonated molecular ion of MA and MA-d{sub 14} (m/z 150 and 164) were isolated and further fragmented, the respective product ions, m/z 119 and 130, were collected for quantitative determination. This is an improvement of our previous method (A.C. Lua, Tsong-Yung Chou, J. Chromatogr. A 967 (2002) 191). In the previous method, MA was separated with HPLC, the efflux was fractionated and each fraction was either determined with an immunoassay or GC/MS. Monitoring of MA in the efflux is tedious and time consuming. Urine samples spiked with different concentrations of D-MA were measured by this method. A linear relationship exists in the 150-1050 ng/mL range, and the detection limit (defined as signal-to-noise ratio 3) of D-MA was determined to be 18 ng/mL. The linearity of the method for D-MA can be described by the equation (Y = 1.415 x 10{sup -3} X + 0.034, correlation coefficient: r {sup 2} = 0.999). Within run, accuracy and precision (n = 6, relative error: -7.2 to +4.0% and relative standard deviation: 3.8-9.3%) of the method are fairly good.

  8. A study of retention characteristics and quality control of nutraceuticals containing resveratrol and polydatin using fused-core column chromatography.

    Science.gov (United States)

    Fibigr, Jakub; Šatínský, Dalibor; Solich, Petr

    2016-02-20

    A new high-performance liquid chromatography method using fused-core column for fast separation of resveratrol and polydatin has been developed and used for quality control of nutraceuticals with resveratrol and polydatin content. Retention characteristics (log k) were studied under different conditions on C-18, RP-Amide C-18, Phenyl-hexyl, Pentafluorophenyl (F5) and Cyano stationary phases for both compounds. The effect of the volume fraction of acetonitrile on a retention factors log k of resveratrol and polydatin were evaluated. The optimal separation conditions for resveratrol, polydatin and internal standard p-nitrophenol were found on the fused-core column Ascentis Express ES-Cyano (100×3.0mm), particle size 2.7μm, with mobile phase acetonitrile/water solution with 0.5% acetic acid pH 3 (20:80, v/v) at a flow rate of 1.0mL/min and at 60°C. The detection wavelength was set at 305nm. Under the optimal chromatographic conditions, good linearity with regression coefficients in the range (r=0.9992-0.9998; n=10) for both compounds was achieved. Commercial samples of nutraceuticals were extracted with methanol using ultrasound bath for 15min. A 5μL sample volume of the filtered solution was directly injected into the HPLC system. Accuracy of the method defined as a mean recovery was in the range 83.2-107.3% for both nutraceuticals. The intraday method precision was found satisfactory and relative standard deviations of sample analysis were in the range 0.8-4.7%. The developed method has shown high sample throughput during sample preparation process, modern separation approach, and short time (3min) of analysis. The results of study showed that the declared content of resveratrol and polydatin varied widely in different nutraceuticals according the producers (71.50-115.00% of declared content). Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Study on automatic control of high uranium concentration solvent extraction with pulse sieve-plate column

    International Nuclear Information System (INIS)

    You Wenzhi; Xing Guangxuan; Long Maoxiong; Zhang Jianmin; Zhou Qin; Chen Fuping; Ye Lingfeng

    1998-01-01

    The author mainly described the working condition of the automatic control system of high uranium concentration solvent extraction with pulse sieve-plate column on a large scale test. The use of the automatic instrument and meter, automatic control circuit, and the best feedback control point of the solvent extraction processing with pulse sieve-plate column are discussed in detail. The writers point out the success of this experiment on automation, also present some questions that should be cared for the automatic control, instruments and meters in production in the future

  10. On-line control of a liquid-liquid extraction column by the modal control method

    International Nuclear Information System (INIS)

    Bonnefoi, P.; Poujol, A.; Zwingelstein, G.; Dargier, C.; Rouyer, H.

    1977-02-01

    The application of modal analysis to the on-line control of a liquid-liquid extraction column is presented. This process is used in reprocessing for U purification. U in the aqueous acid phase is extracted by a solvent flowing at counter-current. The process is described by 4 nonlinear equations and gives the U and acid concentrations in the two phases. An approximative model is established adapted to the control of the column. Some results of a numerical simulation are given when a single mode is controled. They show that a single sensor allows a good control [fr

  11. Exogenous factors contributing to column bed heterogeneity: Part 1: Consequences of 'air' injections in liquid chromatography.

    Science.gov (United States)

    Samuelsson, Jörgen; Fornstedt, Torgny; Shalliker, Andrew

    2015-08-07

    It has been shown that not only the packing homogeneity, but also factors external to the column bed, such as, frits and distributors can have important effects on the column performance. This current communication is the first in a series focusing on the impact of exogenous factors on the column bed heterogeneity. This study is based on several observations by us and others that chromatographic runs often, for technical reasons, include more or less portions of air in the injections. It is therefore extremely important to find out the impact of air on the column performance, the reliability of the results derived from analyses where air was injected, and the effect on the column homogeneity. We used a photographic approach for visualising the air transport phenomena, and found that the air transport through the column is comprised of many different types of transport phenomena, such as laminal flow, viscous fingering like flows, channels and bulbs, and pulsations. More particularly, the air clouds within the column definitely interact in the adsorption, i.e. mobile phase adsorbed to the column surface is displaced. In addition, irrespective of the type of air transport phenomena, the air does not penetrate the column homogeneously. This process is strongly flow dependent. In this work we study air transport both in an analytical scale and a semi-prep column. Copyright © 2015. Published by Elsevier B.V.

  12. Pre-column dilution large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of multi-class pesticides in cabbages.

    Science.gov (United States)

    Zhong, Qisheng; Shen, Lingling; Liu, Jiaqi; Yu, Dianbao; Li, Siming; Yao, Jinting; Zhan, Song; Huang, Taohong; Hashi, Yuki; Kawano, Shin-ichi; Liu, Zhaofeng; Zhou, Ting

    2016-04-15

    Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), was developed in this study. The PD-LVI UHPLC-MS/MS system was designed by slightly modifying the commercial UHPLC-MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC-MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074-0.8 ng/kg) were obtained. The recoveries were in the range of 63.3-109% with relative standard deviations less than 8.1%. Compared with common UHPLC-MS/MS technique, PD-LVI UHPLC-MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC-MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Column selectivity in reversed-phase liquid chromatography I. A general quantitative relationship.

    Science.gov (United States)

    Wilson, N S; Nelson, M D; Dolan, J W; Snyder, L R; Wolcott, R G; Carr, P W

    2002-07-05

    Retention factors k have been measured for 67 neutral, acidic and basic solutes of highly diverse molecular structure (size, shape, polarity, hydrogen bonding, pKa, etc.) on 10 different C18 columns (other conditions constant). These data have been combined with k values from a previous study (86 solutes, five different C8 and C18 columns) to develop a six-term equation for the correlation of retention as a function of solute and column. Values of k can be correlated with an accuracy of +/- 1-2% (1 standard deviation). This suggests that all significant contributions to column selectivity have been identified (and can be measured) for individual alkyl-silica columns which do not have an embedded polar group. That is, columns of the latter kind can be quantitatively characterized in terms of selectivity for use in the separation of any sample.

  14. Simple column-switching ion chromatography method for determining eight monosaccharides and oligosaccharides in honeydew and nectar.

    Science.gov (United States)

    Ni, Chengzhu; Zhu, Binhe; Wang, Nani; Wang, Muhua; Chen, Suqing; Zhang, Jiajie; Zhu, Yan

    2016-03-01

    Honeydew is excreted by aphids as a sweet waste and nectar is floral honey. Honeydew and nectar are complicated samples which consist of various sugars and amino acids. In this work, a simple ion chromatography with column-switching method was developed for the simultaneous analysis of 8 monosaccharides and oligosaccharides in honeydew and nectar. A reversed-phase column was used as a pretreatment column to eliminate organics on-line and sugars were eluted from a collection loop to analytical column by using column-switching technique. This method showed good linearity (r⩾0.9994) and afforded low limits of detection ranging from 1.55 to 10.17μgL(-1) for all the analytes. Recoveries ranged from 95% to 105% and repeatability results were acceptable with relative standard deviation of less than 3.21% (n=6). This method was successfully applied to quantification of these sugars in honeydew and nectar. These results showed honeydew had much more oligosaccharides than nectar. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Accurate measurements of infinite dilution activity coefficients using gas chromatography with static-wall-coated open-tubular columns.

    Science.gov (United States)

    Xu, Qianqian; Su, Baogen; Luo, Xinyi; Xing, Huabin; Bao, Zongbi; Yang, Qiwei; Yang, Yiwen; Ren, Qilong

    2012-11-06

    Wall-coated open-tubular (WCOT) columns provide higher column efficiency and lower solute interfacial adsorption effect than packed columns. However, previous efforts used to measure the infinite dilution activity coefficient (γ(∞)) via a chromatographic technique have used packed columns, because the low carrier gas flow rate (U) and the small stationary phase amount (n(2)) in WCOT columns raise large errors. By rationally revising the γ(∞)-calculation equation for static-wall-coated open-tubular column, we observed that U and n(2) are not necessarily needed and the resulting error could be reduced, and WCOT column gas chromatography subsequently became a superior method for the accurate γ(∞) determination. In this study, we validate our revised γ(∞)-calculation equation by measuring γ(∞) in an ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate system, in which 55 organic compounds covering a wide range of functional groups were used as probe solutes and their γ(∞) values in the ionic liquid were determined at 40.0, 50.0, and 60.0 °C. Experimental error analysis shows that our revised equation remarkably reduces the error compared to the common γ(∞)-calculation equation. Our data is consistent with previously reported values obtained via other techniques, which further proves the credibility of our revised equation. The accurately determined γ(∞) values can be directly used to calculate the partial molar excess enthalpy, selectivity, and capacity, which will benefit for the rapid screening of solvents (especially ionic liquids) in separation approaches.

  16. Estimation of uranium isotope in urine samples using extraction chromatography resin

    International Nuclear Information System (INIS)

    Thakur, Smita S.; Yadav, J.R.; Rao, D.D.

    2012-01-01

    Internal exposure monitoring for alpha emitting radionuclides is carried out by bioassay samples analysis. For occupational radiation workers handling uranium in reprocessing or fuel fabrication facilities, there exists a possibility of internal exposure and urine assay is the preferred method for monitoring such exposure. Estimation of lower concentration of uranium at mBq level by alpha spectrometry requires preconcentration and its separation from large volume of urine sample. For this purpose, urine samples collected from non radiation workers were spiked with 232 U tracer at mBq level to estimate the chemical yield. Uranium in urine sample was pre-concentrated by calcium phosphate coprecipitation and separated by extraction chromatography resin U/TEVA. In this resin extractant was DAAP (Diamylamylphosphonate) supported on inert Amberlite XAD-7 support material. After co-precipitation, precipitate was centrifuged and dissolved in 10 ml of 1M Al(NO 3 ) 3 prepared in 3M HNO 3 . The sample thus prepared was loaded on extraction chromatography resin, pre-conditioned with 10 ml of 3M HNO 3 . Column was washed with 10 ml of 3M HNO 3 . Column was again rinsed with 5 ml of 9M HCl followed by 20 ml of 0.05 M oxalic acid prepared in 5M HCl to remove interference due to Th and Np if present in the sample. Uranium was eluted from U/TEVA column with 15 ml of 0.01M HCl. The eluted uranium fraction was electrodeposited on stainless steel planchet and counted by alpha spectrometry for 360000 sec. Approximate analysis time involved from sample loading to stripping is 2 hours when compared with the time involved of 3.5 hours by conventional ion exchange method. Seven urine samples from non radiation worker were radio chemically analyzed by this technique and the radiochemical yield was found in the range of 69-91 %. Efficacy of this method against conventional anion exchange technique earlier standardized at this laboratory is also being highlighted. Minimum detectable activity

  17. A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Khayoon, Wejdan Shakir; Saad, Bahruddin; Salleh, Baharuddin; Ismail, Nor Azliza; Abdul Manaf, Normaliza Hj; Abdul Latiff, Aishah

    2010-10-29

    The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B(1) and fumonisin B(2) by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C(18) solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith(®) RP-18e column (100 mm × 4.6 mm) at 30 °C and eluted with a mobile phase of a mixture of methanol and phosphate buffer pH 3.35 (78:22, v/v) at a flow rate of 1.0 mL min(-1). The fumonisins separation was achieved in about 4 min, compared to approximately 20 min by using a C(18) particle-packed column. The fluorescence excitation and emission were at 335 nm and 440 nm, respectively. The limits of detections were 0.01-0.04 μg g(-1) fumonisin B(1) and fumonisin B(2), respectively. Good recoveries were found for spiked samples (0.1, 0.5, 1.5 μg g(-1) fumonisins B(1) and B(2)), ranging from 84.0 to 106.0% for fumonisin B(1) and from 81.0 to 103.0% for fumonisin B(2). Fifty-three samples were analyzed including 39 food and feeds and 14 inoculated corn and rice. Results show that 12.8% of the food and feed samples were contaminated with fumonisin B(1) (range, 0.01-0.51 μg g(-1)) and fumonisin B(2) (0.05 μg g(-1)). The total fumonisins in these samples however, do not exceed the legal limits established by the European Union of 0.8 μg g(-1). Of the 14 inoculated samples, 57.1% contained fumonisin B(1) (0.16-41.0 μg g(-1)) and fumonisin B(2) (range, 0.22-50.0 μg g(-1)). Positive confirmation of selected samples was carried out using

  18. A strategy for efficient discovery of new natural compounds by integrating orthogonal column chromatography and liquid chromatography/mass spectrometry analysis: Its application in Panax ginseng, Panax quinquefolium and Panax notoginseng to characterize 437 potential new ginsenosides.

    Science.gov (United States)

    Yang, Wen-zhi; Ye, Min; Qiao, Xue; Liu, Chun-fang; Miao, Wen-juan; Bo, Tao; Tao, Hai-yan; Guo, De-an

    2012-08-20

    To discover new natural compounds from herbal medicines tends to be more and more difficult. In this paper, a strategy integrating orthogonal column chromatography and liquid chromatography/mass spectrometry (LC/MS) analysis was proposed, and was applied for rapid discovery of new ginsenosides from Panax ginseng (PG), Panax quinquefolium (PQ), and Panax notoginseng (PN). The ginsenosides extracts were fractionated by MCI gel×silica gel orthogonal column chromatography. The fractions were then separated on a C(18) HPLC column, eluted with a three-component mobile phase (CH(3)CN/CH(3)OH/3mM CH(3)COONH(4)H(2)O), and detected by electrospray ionization tandem mass spectrometry. The structures of unknown ginsenosides were elucidated by analyzing negative and positive ion mass spectra, which provided complementary information on the sapogenins and oligosaccharide chains, respectively. A total of 623 comprising 437 potential new ginsenosides were characterized from the ethanol extracts of PG, PQ and PN. New acylations, diversified saccharide chains and C-17 side chains constituted novelty of the newly identified ginsenosides. An interpretation guideline was proposed for structural characterization of unknown ginsenosides by LC/MS. To confirm reliability of this strategy, two targeted unknown trace ginsenosides were obtained in pure form by LC/MS-guided isolation. Based on extensive NMR spectroscopic analysis and other techniques, they were identified as 3-O-[6-O-(E)-butenoyl-β-D-glucopyranosyl(1,2)-β-D-glucopyranosyl]-20(S)-protopanaxadiol-20-O-β-D-glucopyranosyl(1,6)-β-D-glucopyranoside (named ginsenoside IV) and 3-O-β-D-glucopyranosyl(1,2)-β-D-glucopyranosyl-3β,12β,20(S),24(R)-tetra hydroxy-dammar-25-ene-20-O-β-D-glucopyranosyl(1,6)-β-D-glucopyranoside (ginsenoside V), respectively. The fully established structures were consistent with the MS-oriented structural elucidation. This study expanded our understanding on ginsenosides of Panax species, and the

  19. Determination of trace amounts of hydroperoxides by column liquid chromatography and colorimetric detection

    NARCIS (Netherlands)

    Deelder, R.S.; Kroll, M.; van den Berg, J.H.M.

    1976-01-01

    The sensitive and selective determination of separated compounds in effluents from liquid chromatographic columns can be carried out by continuously adding a suitable colorimetric agent to the column effluent and continuously monitoring the absorbance of the reaction mixture. However, a considerable

  20. An all-glass solid sampling device for open tubular columns in gas chromatography

    NARCIS (Netherlands)

    Cox, T.P.H.; vd Berg, P.M.J.

    1972-01-01

    An all-glass system for direct sample-introduction of high-boiling compounds onto open tubular columns is described. The standard deviation for quantitative measurements is less than 2.7%. The loss in resolving power of capillary columns, due to this injection system is negligible. The system is

  1. Monolithic columns with organic sorbent based on poly-1-vinylimidazole for high performance liquid chromatography

    Science.gov (United States)

    Patrushev, Y. V.; Sidelnikov, V. N.; Yudina, Y. S.

    2017-03-01

    Monolithic chromatographic columns for HPLC with sorbent based on 1-vinylimidazole are prepared. It is shown that changing the 1-vinylimidazole content in the initial solution allows us to change the polarity of columns. An example of aromatic hydrocarbons separation is presented.

  2. Characterisation of capillary ionic liquid columns for gas chromatography-mass spectrometry analysis of fatty acid methyl esters.

    Science.gov (United States)

    Zeng, Annie Xu; Chin, Sung-Tong; Nolvachai, Yada; Kulsing, Chadin; Sidisky, Leonard M; Marriott, Philip J

    2013-11-25

    Due to their distinct chemical properties, the application of ionic liquid (IL) compounds as gas chromatography (GC) stationary phases offer unique GC separation especially in the analysis of geometric and positional fatty acid methyl ester (FAME) isomers. Elution behaviour of FAME on several commercialised IL capillary columns including phosphonium based SLB-IL59, SLB-IL60, SLB-IL61 and SLB-IL76 and imidazolium based SLB-IL82, SLB-IL100, and SLB-IL111 as well as a general purpose column SLB-5ms, were evaluated in gas chromatography-mass spectrometry (GC-MS) analysis. The phases were further characterised by using a linear solvation energy relationship (LSER) approach according to the equivalent chain length (ECL) index of FAME. Among all tested IL columns, elution temperatures of saturated FAME increased as their McReynolds' polarity value decreased, except for IL60. ECL values increased markedly as the stationary phase polarity increased, particularly for the polyunsaturated FAME. The LSER study indicated a lowest l/e value at 0.864 for IL111, displaying phase selectivity towards unsaturated FAME, with higher peak capacity within a carbon number isomer group. s and e descriptors calculated from LSER were validated by excellent correlation with dipole moments and lowest unoccupied molecular orbital (LUMO) energies, with R(2) values of 0.99 and 0.92 respectively, calculated using GAUSSIAN. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Development and validation of a high-performance liquid chromatography method with post-column derivatization for the detection of aflatoxins in cereals and grains.

    Science.gov (United States)

    Asghar, Muhammad Asif; Iqbal, Javed; Ahmed, Aftab; Khan, Mobeen Ahmed; Shamsuddin, Zuzzer Ali; Jamil, Khalid

    2016-06-01

    A novel, reliable and rapid high-performance liquid chromatography (HPLC) method with post-column derivatization was developed and validated. The HPLC method was used for the simultaneous determination of aflatoxin B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2) in various cereals and grains. Samples were extracted with 80:20 (v/v) methanol:water and purified using C18 (40-63 μm) solid-phase extraction cartridges. AFs were separated using a LiChroCART-RP-18 (5 μm, 250 × 4.0 mm(2)) column. The mobile phase consisted of methanol:acetonitrile:buffer (17.5:17.5:65 v/v) (pH 7.4) delivered at the flow rate of 1.0 mL min(-1) The fluorescence of each AF was detected at λex = 365 nm and λem = 435 nm. All four AFs were properly resolved within the total run time of 20 min. The established method was extensively validated as a final verification of the method development by the evaluation of selectivity (AFB1, AFB2, AFG1 and AFG2), linearity (R(2) ≥ 0.9994), precision (average SD ≤ 2.79), accuracy (relative mean error ≤ -5.51), robustness (p HPLC method could be effectively applied for the routine analysis of the AFs in different cereals and grains. © The Author(s) 2014.

  4. Extraction chromatography of indium (III) on silica gel impregnated with high molecular weight carboxylic acid and its analytical applications

    International Nuclear Information System (INIS)

    Majumdar, P.S.; Ray, U.S.

    1991-01-01

    Indium(III) was separated by extraction chromatography with Versatic 10 as a stationary phase on a column of silica gel from acetic acid and sodium acetate solution (pH 4.5-6.0). The optimum condition for extraction was studied based on the critical study of the relevant factors as effects of pH, flow rate on extraction and elution. Role of stripping agents on the elution was studied. The separation of indium from a number of elements was carried out. Indium(III) was separated from Alsup(III), Gasup(III), Tlsup(III), Zrsup(IV) and trivalent lanthanides which interfere under the recommended extraction condition by exploiting the differences in their stripping behaviour. (author). 7 refs., 1 tab., 1 fig

  5. Determination of flumequine and oxolinic acid in sediments and soils by microwave-assisted extraction and liquid chromatography-fluorescence

    International Nuclear Information System (INIS)

    Prat, M.D.; Ramil, D.; Compano, R.; Hernandez-Arteseros, J.A.; Granados, M.

    2006-01-01

    A method is reported for the determination of the quinolones oxolinic acid and flumequine in aquatic sediments and agricultural soils. The analytes are extracted by liquid-liquid partitioning between a sample homogenated in an aqueous buffer solution and dichloromethane. Microwave-assisted extraction (MAE) was tested to improve the speed and efficiency of the extraction process. The parameters affecting the efficiency of MAE, such as irradiation time and temperature, were studied. The clean-up consists of back-extraction in 1 M sodium hydroxide. The determination is carried out by reversed phase liquid chromatography on an octyl silica-based column and fluorimetric detection. The optimised method was applied to the analysis of two sediments and one agricultural soil spiked with the analytes. The absolute recovery rates for the whole process range from 79% to 94% (RSD 3-7%), and detection limits are in the low μg kg -1 level

  6. High-performance liquid chromatography coupled with post-column dual-bioactivity assay for simultaneous screening of xanthine oxidase inhibitors and free radical scavengers from complex mixture.

    Science.gov (United States)

    Li, D Q; Zhao, J; Li, S P

    2014-06-06

    Xanthine oxidase (XO) can catalyze hypoxanthine and xanthine to generate uric acid and reactive oxygen species (ROS), including superoxide anion radical (O₂(•-)) and hydrogen peroxide. XO inhibitors and free radical scavengers are beneficial to the treatment of gout and many related diseases. In the present study, an on-line high-performance liquid chromatography (HPLC) coupled with post-column dual-bioactivity assay was established and successfully applied to simultaneously screening of XO inhibitors and free radical scavengers from a complex mixture, Oroxylum indicum extract. The integrated system of HPLC separation, bioactivity screening and mass spectrometry identification was proved to be simple and effective for rapid and sensitive screening of individual bioactive compounds in complex mixtures. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Normal and Reversed-Phase Thin Layer Chromatography of Green Leaf Extracts

    Science.gov (United States)

    Sjursnes, Birte Johanne; Kvittingen, Lise; Schmid, Rudolf

    2015-01-01

    Introductory experiments of chromatography are often conducted by separating colored samples, such as inks, dyes, and plant extracts, using filter paper, chalk, or thin layer chromatography (TLC) plates with various solvent systems. Many simple experiments have been reported. The relationship between normal chromatography and reversed-phase…

  8. A study of flow performance and flooding in pulsed sieve plate extraction columns

    International Nuclear Information System (INIS)

    Zhang Quanrong; Wang Ruipian

    1986-01-01

    The pulsed sieve plate extraction columns could be divided into two types. The type II which has larger coalescence-damping coefficient K has an apparent transition region that widens when the K value has been increased. In this time, the operation condition in the column of type II is very different from that of type I. The flooding could be divided into three types: the flooding due to insufficient pulsing; emulsion flooding; and flooding due to dispersed phase and continuous phase that replace each other. The three kinds of flooding in the column of type II are very different from that in the column of type I. In the column of type II, when the value of K is about 2 to 3, emulsion flooding has occured and flooding capacity is the largest. In that column. The largest flooding capacity is usually larger than 1300 l/dm 2 · hr when the system 30% TBP(OK)-HNO 3 is used, but it cannot be used under normal conditions when the K value is larger

  9. Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties.

    Science.gov (United States)

    Šatínský, Dalibor; Chocholouš, Petr; Válová, Olga; Hanusová, Lucia; Solich, Petr

    2013-09-30

    This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Determination of 90Sr in low-level radioactive wastes using extraction chromatography and LSC

    International Nuclear Information System (INIS)

    Temba, Eliane S.C.; Reis Junior, Aluisio S.; Mingote, Raquel M.; Monteiro, Roberto P.G.

    2009-01-01

    A procedure for the determination of 90 Sr in low-level radioactive wastes is presented in this work. It is a part of a methodology developed for the sequential radiochemical separation of radionuclides in low-level radioactive wastes. These radionuclides comprises the actinides and 55 Fe, 63 Ni and 90 Sr, classified as difficult-to-measure (DTM) radionuclides in the radioactive waste characterization, because they cannot be measured by direct measurements, like gamma spectrometry. A variety of methods have been reported in the literature, based on precipitation, liquid-liquid extraction and ion exchange. In this work, the separation was carried out using precipitation and extraction chromatography using the Sr Resin (Eichrom). This resin is strontium-selective, the extractant is a crown ether-derivative immobilized on an inert polymeric support. The 90 Sr eluted from column was measured by LSC. The counting was carried out within 5 hours of the start of yttrium ingrowth to minimize interferences from 90 Y. The counting efficiency was calculated by using a 90 Sr standard solution purified by the specific resin. The chemical yield of the procedure was determined gravimetrically by the addition of a stable Sr carrier. Optimum conditions for the pretreatment, separation and LSC setting were determined using simulated samples. This procedure showed to be rapid and achieved a good chemical recovery, with an average of 84 %, and a detection limit of 0.6 Bq L -1 . (author)

  11. Direct enantioseparation of nitrogen-heterocyclic pesticides on cellulose-based chiral column by high-performance liquid chromatography.

    Science.gov (United States)

    Chai, Tingting; Yang, Wenwen; Qiu, Jing; Hou, Shicong

    2015-01-01

    The enantiomeric separation of eight pesticides including bitertanol (), diclobutrazol (), fenbuconazole (), triticonazole (), imazalil (), triapenthenol (), ancymidol (), and carfentrazone-ethyl () was achieved, using normal-phase high-performance liquid chromatography on two cellulosed-based chiral columns. The effects of isopropanol composition from 2% to 30% in the mobile phase and column temperature from 5 to 40 °C were investigated. Satisfactory resolutions were obtained for bitertanol (), triticonazole (), imazalil () with the (+)-enantiomer eluted first and fenbuconazole () with the (-)-enantiomer eluted first on Lux Cellulose-2 and Lux Cellulose-3. (+)-Enantiomers of diclobutrazol () and triapenthenol () were first eluted on Lux Cellulose-2. (-)-Carfentrazone-ethyl () were eluted first on Lux Cellulose-2 and Lux Cellulose-3 with incomplete separation. Reversed elution orders were obtained for ancymidol (7). (+)-Ancymidol was first eluted on Lux Cellulose-2 while on Lux Cellulose-3 (-)-ancymidol was first eluted. The results of the elution order at different column temperatures suggested that column temperature did not affect the optical signals of the enantiomers. These results will be helpful to prepare and analyze individual enantiomers of chiral pesticides. © 2014 Wiley Periodicals, Inc.

  12. Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions

    Science.gov (United States)

    Al-Degs, Yahya; Andri, Bertyl; Thiébaut, Didier; Vial, Jérôme

    2017-01-01

    Retention mechanisms involved in supercritical fluid chromatography (SFC) are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase), a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC) was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition). Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition) data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns' function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components. PMID:28695040

  13. Study on the dynamic holdup distribution of the pulsed extraction column

    International Nuclear Information System (INIS)

    Wang, S.; Chen, J.; Wu, Q.

    2013-01-01

    In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

  14. Study on the dynamic holdup distribution of the pulsed extraction column

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.; Chen, J.; Wu, Q. [Tsinghua University, Beijing 100084 (China)

    2013-07-01

    In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

  15. Determination of alpidem, an imidazopyridine anxiolytic, and its metabolites by column-switching high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Flaminio, L; Ripamonti, M; Ascalone, V

    1994-05-13

    Alpidem, 6-chloro-2-(4-chlorophenyl)-N,N-dipropylimidazo[1,2-a]pyridine- 3-acetamide, is an anxiolytic imidazopyridine that undergoes a first-pass elimination after oral administration to humans; it is actively metabolized and three circulating metabolites have been identified in plasma due to N-dealkylation, oxidation or a combination of both processes. For the determination of the unchanged drug and its metabolites in human plasma, a column-switching HPLC method was developed. The method, based on solid-phase extraction (performed on-line), involves the automatic injection of plasma samples (200 microliters) on to a precolumn filled with C18 material, clean-up of the sample with water in order to remove protein and salts and transfer of the analytes to the analytical column (after valve switching) by means of the mobile phase. All the processes were performed in the presence of an internal standard, a compound chemically related to alpidem. During the analytical chromatography, the precolumn was flushed with different solvents and after regeneration with water, it was ready for further injections. The analytical column was a C8 type and the mobile phase was acetonitrile-methanol-phosphate buffer solution (45:15:45, v/v/v) at a flow-rate of 1.5 ml min-1. The column was connected to a fluorimetric detector operating at excitation and emission wavelengths of 255 and 423 nm, respectively. The limits of quantitation of alpidem and three metabolites were 2.5 and 1.5 ng ml-1, respectively, in human plasma.

  16. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  17. Micro-fabricated packed gas chromatography column based on laser etching technology.

    Science.gov (United States)

    Sun, J H; Guan, F Y; Zhu, X F; Ning, Z W; Ma, T J; Liu, J H; Deng, T

    2016-01-15

    In this work, a micro packed gas chromatograph column integrated with a micro heater was fabricated by using laser etching technology (LET) for analyzing environmental gases. LET is a powerful tool to etch deep well-shaped channels on the glass wafer, and it is the most effective way to increase depth of channels. The fabricated packed GC column with a length of over 1.6m, to our best knowledge, which is the longest so far. In addition, the fabricated column with a rectangular cross section of 1.2mm (depth) × 0.6mm (width) has a large aspect ratio of 2:1. The results show that the fabricated packed column had a large sample capacity, achieved a separation efficiency of about 5800 plates/m and eluted highly symmetrical Gaussian peaks. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Mobile phase effects on the retention on polar columns with special attention to the dual hydrophilic interaction-reversed-phase liquid chromatography mechanism, a review.

    Science.gov (United States)

    Jandera, Pavel; Hájek, Tomáš

    2018-01-01

    Hydrophilic interaction liquid chromatography on polar columns in aqueous-organic mobile phases has become increasingly popular for the separation of many biologically important compounds in chemical, environmental, food, toxicological, and other samples. In spite of many new applications appearing in literature, the retention mechanism is still controversial. This review addresses recent progress in understanding of the retention models in hydrophilic interaction liquid chromatography. The main attention is focused on the role of water, both adsorbed by the column and contained in the bulk mobile phase. Further, the theoretical retention models in the isocratic and gradient elution modes are discussed. The dual hydrophilic interaction liquid chromatography reversed-phase retention mechanism on polar columns is treated in detail, especially with respect to the practical use in one- and two-dimensional liquid chromatography separations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The Binding of Biotin to Sepharose-Avidin Column: Demonstration of the Affinity Chromatography Technique

    Science.gov (United States)

    Landman, A. D.; Landman, N. N.

    1976-01-01

    Describes a biochemistry experiment that illustrates the methodology of affinity chromatography by attaching avidin, a glycoprotein in egg white, to a Sepharose matrix in order to bind biotin-containing proteins. (MLH)

  20. Pressure drop effects on selectivity and resolution in packed-column supercritical fluid chromatography

    NARCIS (Netherlands)

    Lou, X.W.; Janssen, J.G.M.; Snijders, H.M.J.; Cramers, C.A.M.G.

    1996-01-01

    The influence of pressure drop on retention, selectivity, plate height and resolution was investigated systematically in packed supercritical fluid chromatography (SFC) using pure carbon dioxide as the mobile phase. Numerical methods developed previously which enabled the prediction of pressure

  1. Application of liquid column chromatography to preconcentration, separation and determination of platinum metals

    International Nuclear Information System (INIS)

    Alimarin, I.P.; Basova, E.M.; Bol'shova, T.A.; Ivanov, V.M.

    1986-01-01

    Separation and determination of platimum metals using the methods of adsorption, ion-pair, ion-exchange, distributing and sieve chromatography are discussed in the review of literature in 1971-1984. Separation and determination of metals as chelates using the method of adsorption and ion-pair chromatograpy are noted to be most perspective directions of developing highly effective liquid chromatography of inorganic systems

  2. Developing of Ytrium-90 Generator Based on Extraction Chromatography with Crown Ether

    International Nuclear Information System (INIS)

    Yassine, T.; Mukhallalati, Ch.H.

    2009-01-01

    Although the use of radionuclides for therapeutic purposed goes back to about 60 years ago, but interest in this therapy is rapidly increasing in the field of nuclear medicine. The introduction and acceleration of such techniques require the continuous availability and acceptable cost of therapeutic radionuclides and radiopharmaceuticals. Most of therapeutic radionuclides, are reactor (Ho-166, Lu-177 Sm-153, I-131...). Produced ones which makes the generator produced radionuclides such Y-90, is more convenient to start with for developing therapeutic radiopharmaceutical in countries where there are no reactor. Ytrium-90 is an important radionuclide for radioimmunotherapeutic and for radiosynviorethesis. It is pure single high energy beta emitter (Ep=2.3 Mev), decaying to stable Zirconium-90 with half-life of about 64 hrs. It is availability, as generator products resulting from the decay of the long lived strontium-90 (T1/2 = 28y) has increased its importance in nuclear medicine and accelerated its applications. The AECS has initiated wide Programme for development and production of radiopharmaceuticals for covering local and regional demands of nuclear medicine. Existed facility including Cyclotron (cyclon 30 IBA), technetium-99m generator and kits production lines and iodine-131 dispensing and labeling plant, needs to be enhanced by more therapeutic products. The absence of nuclear reactor for radionuclide production makes the generator technology to be a convenient choice. Therefore, Ytrium-90 radiopharmaceuticals were targeted and 90Sr/90Y generator was developed for these purposes. Several designs of Ytrium-90 generator were developed according to different separation techniques, such as solvent extraction, ion exchange, supported liquid membrane and electrodeposition, and each has deferent characterizations and Performances. We found that extraction Chromatography by 18C6 Crown ether loaded on Teflon resins (Sr-Spec) is very convenient for Production of ultra

  3. The determination of organochlorine pesticides based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Chen Ligang; Ding Lan; Jin Haiyan; Song Daqian; Zhang Huarong; Li Jiantao; Zhang Kun; Wang Yutang; Zhang Hanqi

    2007-01-01

    A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM 010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min -1 . The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g -1 . The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required

  4. 3D printed titanium micro-bore columns containing polymer monoliths for reversed-phase liquid chromatography.

    Science.gov (United States)

    Gupta, Vipul; Talebi, Mohammad; Deverell, Jeremy; Sandron, Sara; Nesterenko, Pavel N; Heery, Brendan; Thompson, Fletcher; Beirne, Stephen; Wallace, Gordon G; Paull, Brett

    2016-03-03

    The potential of 3D selective laser melting (SLM) technology to produce compact, temperature and pressure stable titanium alloy chromatographic columns is explored. A micro bore channel (0.9 mm I.D. × 600 mm long) was produced within a 5 × 30 × 30 mm titanium alloy (Ti-6Al-4V) cuboid, in form of a double handed spiral. A poly(butyl methacrylate-co-ethyleneglycoldimethacrylate) (BuMA-co-EDMA) monolithic stationary phase was thermally polymerised within the channel for application in reversed-phase high-performance liquid chromatography. The prepared monolithic column was applied to the liquid chromatographic separation of intact proteins and peptides. Peak capacities of 69-76 (for 6-8 proteins respectively) were observed during isothermal separation of proteins at 44 °C which were further increased to 73-77 using a thermal step gradient with programmed temperature from 60 °C to 35 °C using an in-house built direct-contact heater/cooler platform based upon matching sized Peltier thermoelectric modules. Rapid temperature gradients were possible due to direct-contact between the planar metal column and the Peltier module, and the high thermal conductivity of the titanium column as compared to a similar stainless steel printed column. The separation of peptides released from a digestion of E.coli was also achieved in less than 35 min with ca. 40 distinguishable peaks at 210 nm. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Fast preparation of hybrid monolithic columns via photo-initiated thiol-yne polymerization for capillary liquid chromatography.

    Science.gov (United States)

    Ma, Shujuan; Zhang, Haiyang; Li, Ya; Li, Yanan; Zhang, Na; Ou, Junjie; Ye, Mingliang; Wei, Yinmao

    2018-02-23

    Although several approaches have been developed to fabricate hybrid monoliths, it would still take a few hours to finish the formation of monoliths. Herein, photo-initiated thiol-yne polymerization was first adopted to in situ fabricate hybrid monoliths within the confines of UV-transparent fused-silica capillary. A silicon-containing diyne (1,3-diethynyltetramethyl-disiloxane, DYDS) was copolymerized with three multithiols, 1,6-hexanedithiol, trimethylolpropane tris(3-mercaptopropionate) and pentaerythriol tetrakis(3-mercaptopropionate), by using a binary porogenic system of diethylene glycol diethyl ether (DEGDE)/poly(ethylene glycol) (PEG200) within 10 min. Several characterizations of three hybrid monoliths (assigned as I, II and III, respectively) were performed. The results showed that these hybrid monoliths possessed bicontinuous porous structure, which was remarkably different from that via typical free-radical polymerization. The highest column efficiency of 76,000 plates per meter for butylbenzene was obtained on the column I in reversed-phase liquid chromatography (RPLC). It was observed that the efficiencies for strong-retained butylbenzene were almost close to those of weak-retained benzene, indicating a retention-independent efficient performance of small molecules on hybrid column I. The surface area of this hybrid monolith was very small in the dry state (less than 10.0 m 2 /g), and the chromatographic behavior of hybrid monolithic columns would be possibly explained by radical-mediated step-growth process of thiol-yne polymerization. Finally, the column I was applied for separation of BSA tryptic digest by cLC-MS/MS, indicating satisfactory separation ability for complicated samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Intensified Separation of Steviol Glycosides from a Crude Aqueous Extract of Stevia rebaudiana Leaves Using Centrifugal Partition Chromatography.

    Science.gov (United States)

    Hubert, Jane; Borie, Nicolas; Chollet, Sébastien; Perret, Joël; Barbet-Massin, Claire; Berger, Monique; Daydé, Jean; Renault, Jean-Hugues

    2015-11-01

    Aqueous extracts of Stevia rebaudiana leaves have been approved since 2008 by the Joint Expert Committee for Food Additives as sugar substitutes in many food and beverages in Western and Far East Asian countries. The compounds responsible for the natural sweetness of Stevia leaves include a diversity of diterpenoid glycosides derived from a steviol skeleton. These steviol glycosides also exhibit a low calorific value as well as promising therapeutic applications, particularly for the treatment of sugar metabolism disturbances. In this work, centrifugal partition chromatography is proposed as an efficient technical alternative to purify steviol glycosides from crude aqueous extracts of Stevia leaves on a multigram scale. Two different commercial instruments, including an ASCPC250® and a FCPE300® made of columns containing 1890 and 231 twin-cells, respectively, were evaluated and compared. All experiments were performed with a polar biphasic solvent system composed of ethyl acetate, n-butanol, and water in a gradient elution mode. When using the 1890 partition cell centrifugal partition chromatography column of 250 mL, 42 mg of stevioside, 68 mg of dulcoside A, and 172 mg of rebaudioside A, three major constituents of the initial extract were obtained from 1 g of the initial mixture at purities of 81%, 83%, and 99%, respectively. The productivity was further improved by intensifying the procedure on the 231 partition cell centrifugal partition chromatography column of 303 mL with the sample mass loading increased up to 5 g, resulting in the recovery of 1.2 g of stevioside, 100 mg of dulcoside A, and 1.1 g of rebaudioside A at purities of 79%, 62%, and 98%, respectively. The structures of the isolated compounds were validated by HPLC-UV, ESI-MS, (1)H, and (13)C NMR analyses. Altogether, the results demonstrate that the column design (i.e., the partition cell number) is an important aspect to be considered for a larger scale centrifugal partition chromatography

  7. Twin column chromatography: A new technique for treating limited amounts of waste

    International Nuclear Information System (INIS)

    Wenzel, U.

    1995-01-01

    The authors set up a chromatographic unit for the decontamination of analytical discards from Am and Pu. The unit is based on the twin column concept, i.e. the chromatographic support is accommodated in two identical columns and the detector placed between the columns. Thus, they could employ the wall effects model allowing the evaluation of breakthrough chromatograms at low effluent concentrations and the determination of the design parameters for the lay-out of the unit. The authors verified the model with the unit and obtained a good agreement between measured and calculated parameters. In the test phase, they processed 47 liters discards, they obtained 56 liters decontaminated waste with a DF Am of 770 and a total DF α of 7,000 and 22 liters eluate which was reduced by evaporation to 0.8 liters

  8. Screening of extraction methods for glycoproteins from jellyfish ( Rhopilema esculentum) oral-arms by high performance liquid chromatography

    Science.gov (United States)

    Ren, Guoyan; Li, Bafang; Zhao, Xue; Zhuang, Yongliang; Yan, Mingyan; Hou, Hu; Zhang, Xiukun; Chen, Li

    2009-03-01

    In order to select an optimum extraction method for the target glycoprotein (TGP) from jellyfish ( Rhopilema esculentum) oral-arms, a high performance liquid chromatography (HPLC)-assay for the determination of the TGP was developed. Purified target glycoprotein was taken as a standard glycoprotein. The results showed that the calibration curves for peak area plotted against concentration for TGP were linear ( r = 0.9984, y = 4.5895 x+47.601) over concentrations ranging from 50 to 400 mgL-1. The mean extraction recovery was 97.84% (CV2.60%). The fractions containing TGP were isolated from jellyfish ( R. esculentum) oral-arms by four extraction methods: 1) water extraction (WE), 2) phosphate buffer solution (PBS) extraction (PE), 3) ultrasound-assisted water extraction (UA-WE), 4) ultrasound-assisted PBS extraction (UA-PE). The lyophilized extract was dissolved in Milli-Q water and analyzed directly on a short TSK-GEL G4000PWXL (7.8 mm×300 mm) column. Our results indicated that the UA-PE method was the optimum extraction method selected by HPLC.

  9. Development of a miniature Taylor-Couette extractor column for nuclear solvent extraction

    International Nuclear Information System (INIS)

    Shekhar Kumar; Sivakumar, D.; Bijendra Kumar; Kamachi Mudali, U.; Natarajan, R.

    2012-01-01

    Miniature annular centrifugal contactors are nearly perfect for shielded hot-cell applications during flowsheet evaluation but these contactors require complex maintenance of electrical drive-motors during radioactive experiments. To reduce the number of electrical drives in the shielded cell, an indigenous design of miniature Taylor Couette (TC) mixing based countercurrent differential extraction column has been developed. In this paper, results of mass transfer experiments for an indigenously developed TC column with 30% TBP/aqueous nitric acid solutions are reported. The developed device worked perfectly in counter-current differential mode and demonstrated equivalence to multiple-extraction stages while working with a single electrical drive. The developed TC unit demonstrated operation with a reduced efficiency without flooding even in absence of rotor rotation. This observation is a vital step towards designing of robust contactors, which do not flood during temporary power failure or failure of drive mechanism. (author)

  10. Two approaches for sequential extraction of radionuclides in soils: batch and column methods

    International Nuclear Information System (INIS)

    Vidal, M.; Rauret, G.

    1993-01-01

    A three-step sequential extraction designed by Community Bureau of Reference (BCR) is applied to two types of soil (sandy and sandy-loam) which had been previously contaminated with a radionuclide aerosol containing 134 Cs, 85 Sr and 110m Ag. This scheme is applied using both batch and column methods. The radionuclide distribution obtained with this scheme depends both on the method and on soil type. Compared with the batch method, column extraction is an inadvisable method. Kinetic aspects seem to be important, especially in the first and third fractions. The radionuclide distribution shows that radiostrontium has high mobility, radiocaesium is highly retained by clay minerals whereas Fe/Mn oxides and organic matter have an important role in radiosilver retention. (Author)

  11. "Supermarket Column Chromatography of Leaf Pigments" Revisited: Simple and Ecofriendly Separation of Plant Carotenoids, Chlorophylls, and Flavonoids from Green and Red Leaves

    Science.gov (United States)

    Dias, Alice M.; Ferreira, Maria La Salete

    2015-01-01

    A simple and ecofriendly procedure was developed in order to prepare extracts from red and green leaves. This procedure enables the separation of yellow, green, and red band pigments and optimizes the previously reported baking soda "supermarket column". The same extract also led to a novel and colorful potato starch column, which can…

  12. Column liquid chromatography applied to concentrating, separating, and determining platinum metals

    International Nuclear Information System (INIS)

    Alimarin, I.P.; Basova, E.M.; Bol'shova, T.A.; Ivanov, V.M.

    1986-01-01

    The present survey deals with high-performance liquid chromatography (HPLC) in relation to the chromatographic behavior of the platinum metals, including separation and determination. The data shows that HPLC is the most promising and effective method of separating metals, including platinum ones. The method provides efficient separation of microgram amoounts of mixtures with a resolving power 3-20 times that of thin-layer chromatography. It is shown that the most promising line of advance in HPLC for inorganic systems lies in the separation and determination of metals as chelates by absorption or ion-pair chromatography. Examples of using HPLC for determining noble metals in particular cases indicate that the metrological characteristics are favorable

  13. Preparative isolation of alkaloids from Dactylicapnos scandens using pH-zone-refining counter-current chromatography by changing the length of the separation column.

    Science.gov (United States)

    Wang, Xiao; Dong, Hongjing; Yang, Bin; Liu, Dahui; Duan, Wenjuan; Huang, Luqi

    2011-12-01

    pH-Zone-refining counter-current chromatography was successfully applied for the preparative separation of alkaloids from Dactylicapnos scandens. The two-phase solvent system was composed of petroleum ether-ethyl acetate-methanol-water (3:7:1:9, v/v), where 20 mM of triethylamine (TEA) was added to the upper phase as a retainer and 5 mM of hydrochloric acid (HCl) to the aqueous phase as an eluter. In this experiment, the apparatus with an adjustable length of the separation column was used for the separation of alkaloids from D. scandens and the resolution of the compounds can be remarkably improved by increasing the length of the separation column. As a result, 70 mg protopin, 30 mg (+) corydine, 120 mg (+) isocorydine and 40 mg (+) glaucine were obtained from 1.0 g of the crude extracts and each with 99.2%, 96.5%, 99.3%, 99.5% purity as determined by HPLC. The chemical structures of these compounds were confirmed by positive ESI-MS and (1)H NMR. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Integration of On-Column Chemical Reactions in Protein Characterization by Liquid Chromatography/Mass Spectrometry: Cross-Path Reactive Chromatography.

    Science.gov (United States)

    Pawlowski, Jake W; Carrick, Ian; Kaltashov, Igor A

    2018-01-16

    Profiling of complex proteins by means of mass spectrometry (MS) frequently requires that certain chemical modifications of their covalent structure (e.g., reduction of disulfide bonds), be carried out prior to the MS or MS/MS analysis. Traditionally, these chemical reactions take place in the off-line mode to allow the excess reagents (the majority of which interfere with the MS measurements and degrade the analytical signal) to be removed from the protein solution prior to MS measurements. In addition to a significant increase in the analysis time, chemical reactions may result in a partial or full loss of the protein if the modifications adversely affect its stability, e.g,, making it prone to aggregation. In this work we present a new approach to solving this problem by carrying out the chemical reactions online using the reactive chromatography scheme on a size exclusion chromatography (SEC) platform with MS detection. This is achieved by using a cross-path reaction scheme, i.e., by delaying the protein injection onto the SEC column (with respect to the injection of the reagent plug containing a disulfide-reducing agent), which allows the chemical reactions to be carried out inside the column for a limited (and precisely controlled) period of time, while the two plugs overlap inside the column. The reduced protein elutes separately from the unconsumed reagents, allowing the signal suppression in ESI to be avoided and enabling sensitive MS detection. The new method is used to measure fucosylation levels of a plasma protein haptoglobin at the whole protein level following online reduction of disulfide-linked tetrameric species to monomeric units. The feasibility of top-down fragmentation of disulfide-containing proteins is also demonstrated using β 2 -microglobulin and a monoclonal antibody (mAb). The new online technique is both robust and versatile, as the cross-path scheme can be readily expanded to include multiple reactions in a single experiment (as

  15. Determination of aromatic amines in aqueous extracts of polyurethane foam using hydrophilic interaction liquid chromatography and mass spectrometry

    International Nuclear Information System (INIS)

    Riddar Johnson, Jakob; Karlsson, Daniel; Dalene, Marianne; Skarping, Gunnar

    2010-01-01

    A method is presented for the determination of aromatic amines in aqueous extracts of polyurethane (PUR) foam. The method is based on the extraction of PUR foam using aqueous acetic acid (0.1%, w/v) followed by determination of extracted aromatic amines using hydrophilic interaction liquid chromatography (HILIC) and tandem mass spectrometry (MS/MS) with positive electrospray ionisation. The injections of volumes up to 5 μL of aqueous solutions were made possible by on-column focusing with partially filled loop injections. The fragmentation patterns for 2,4- and 2,6-toluene diamine (TDA) and 4,4'-methylene dianiline (MDA) were clarified by performing a hydrogen-deuterium exchange study. TDA and MDA were determined using trideuterated 2,4- and 2,6-TDA and dideuterated 4,4'-MDA as internal standards. Linear calibration graphs were obtained over the range 0.025-0.5 μg mL -1 with correlation coefficients >0.996 and the instrumental detection limit for each compound was <50 fmol. The stability of the amines was influenced by the matrix, so their concentrations decreased over time. Agreement was observed between the results of analyses of PUR foam extracts by HILIC-MS/MS and results obtained by ethyl chloroformate derivatisation and reversed phase (RP) liquid chromatography-mass spectrometry (LC-MS/MS). TDA was observed to be unstable in extracts of foam but not in pure solutions.

  16. Semi-Automated Hydrophobic Interaction Chromatography Column Scouting Used in the Two-Step Purification of Recombinant Green Fluorescent Protein

    Science.gov (United States)

    Murphy, Patrick J. M.

    2014-01-01

    Background Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Methods and Results Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conclusions Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in

  17. Isolation of two new prenylated flavonoids from Sinopodophyllum emodi fruit by silica gel column and high-speed counter-current chromatography.

    Science.gov (United States)

    Sun, Yanjun; Sun, Yinshi; Chen, Hui; Hao, Zhiyou; Wang, Junmin; Guan, Yanbin; Zhang, Yanli; Feng, Weisheng; Zheng, Xiaoke

    2014-10-15

    Two new prenylated flavonoids, sinoflavonoids A-B, were isolated from the dried fruits of Sinopodophyllum emodi by silica gel column chromatography (SGCC) and high-speed counter-current chromatography (HSCCC). The 95% ethanol extract was partitioned with petroleum ether, dichloromethane, ethyl acetate, and n-butanol in water, respectively. The ethyl acetate fraction was pre-separated by SGCC with a petroleum ether-acetone gradient. The eluates containing target compounds were further separated by HSCCC with n-hexane-ethyl acetate-methanol-water (4:6:4:4, v/v). Finally, 17.3mg of sinoflavonoid A and 25.9mg of sinoflavonoid B were obtained from 100mg of the pretreated concentrate. The purities of sinoflavonoid A and sinoflavonoid B were 98.47% and 99.38%, respectively, as determined by HPLC. Their structures were elucidated on the basis of spectroscopic evidences (HR-ESI-MS, (1)H-NMR, (13)C-NMR, HSQC, HMBC). The separation procedures proved to be efficient, especially for trace prenylated flavonoids. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Separation and preconcentration of uranium from different matrices by extraction chromatography on U-TEVA resin

    International Nuclear Information System (INIS)

    Becquart, Elena T.; Bianco, Gladis N.; Chiacchio, Hugo A.; Palestrini, Leonardo J.; Servant, Roberto E.

    1999-01-01

    The objectives of this work were the determination of uranium in effluents and spring waters, in high and low U 3 O 8 containing minerals and in Zircaloy. The separations were done by extraction chromatography, using U-TEVA Spec (uranium tetravalent actinide specific, ElChroM, Illinois, USA), a commercial resin consisting of Amberlite XAD-7 (Rohm and Haas), an inert support of a non ionic polymeric adsorbent, soaked by diamylamylphosphonate, a selective extractant. Disposable plastic columns, 7.9 mm internal diameter, 10 cm total length, with a bed 4.5 cm high and 2 ml volume were used. Quantification was done by spectrophotometric determination of uranium with the chromogenic reagent 2-(5-bromo-2-pyridylazo)-5-diethyl aminophenol (Br-PADAP). The following working conditions were optimized: uranium sorption and preconcentration, elution, separation of others cations as Zr (IV), Gd (III), Th (IV) and uranium elution, using different solutions of nitric or hydrochloric acids as convenient. Break through was 30 mg of uranium and capacity at total saturation was between 35 and 40 mg U/ml of bed. Programs were developed for previous leaching of minerals and Zircaloy in a microwave oven. Procedures operations were satisfactory with recoveries higher than 95% and a percent relative standard deviation better than 1% for 100 μg of uranium, on five replicates. Quantification limit was 4 ppb (0.1 μg of U in the 25 ml volumetric flask where color was developed with chromogenic reagent), but if uranium is concentrated 5 times in the column and a 5 ml volume is used for elution, a sample containing 0.4 ppb of uranium can be analysed. Absorbance was measured at λ = 578 nm using 5 cm cells. The extraction system is profitable because it allows to work at room temperature, with gravity flow, high specificity and minimum waste generation. The objectives have been satisfactorily accomplished, so an easy, in small columns, uranium sorbing system is available to be used in the

  19. Chromatographic efficiency of polar capillary columns applied for the analysis of fatty acid methyl esters by gas chromatography.

    Science.gov (United States)

    Waktola, Habtewold D; Mjøs, Svein A

    2018-04-01

    The chromatographic efficiency that could be achieved in temperature-programmed gas chromatography was compared for four capillary columns that are typically applied for analysis of fatty acid methyl esters (FAME). Three different carrier gases, hydrogen, helium and nitrogen, were applied. For each experiment, the carrier gas velocities and the temperature rates were varied with a full 9 × 3 design, with nine levels on the carrier gas velocity and temperature rates of 1, 2 or 3°C/min. Response surface methodology was used to create models of chromatographic efficiency as a function of temperature rate and carrier gas velocity. The chromatographic efficiency was defined as the inverse of peak widths measured in retention index units. The final results were standardized so that the efficiencies that could be achieved within a certain time frame, defined by the retention time of the last compound in the chromatogram, could be compared. The results show that there were clear differences in the efficiencies that could be achieved with the different columns and that the efficiency decreased with increasing polarity of the stationary phase. The differences can be explained by higher resistance to mass transfer in the stationary phase in the most polar columns. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Separation of mercury(II), methylmercury and phenylmercury by micellar high-performance liquid chromatography on short columns

    International Nuclear Information System (INIS)

    Hutta, M.; Megova, S.; Halko, R.

    1998-01-01

    Three environmentally and agrochemically important mercury species: methylmercury, phenylmercury and mercury(II) are separated within 4 minutes as bromocomplexes by micellar liquid chromatography using very short reversed-phase (RP) C18 columns (up to 30 mm). The micellar mobile phase containing 0.05M cetyltrimethylammonium bromide (CTMA + Br - ), 1% (v/v) 2-propanol, 0.001M cyclohexylenediaminetetraacetic acid (DCTA) and sulfuric acid (pH 2) showed good selectivity in mixed reversed-phase and anion-exchange mode. The above mentioned separation order in which organomercurials are eluted far behind the void volume of the column, but before the mercury(II) peak is advantageous in all instances where mercury(II) is present in real samples in great excess. Environmental and agrochemical samples contain humic material which does not interfere in this particular system. The low cost photometric detection at 500 nm after post-column derivatization by CTMA + Br - micellized dithizone is almost free from interferences and enables detection limits at the 1-3 ng level (e.g., 0.1 ppm Hg) for 20 μl samples. (author)

  1. On-column nitrosation of amines observed in liquid chromatography impurity separations employing ammonium hydroxide and acetonitrile as mobile phase.

    Science.gov (United States)

    Myers, David P; Hetrick, Evan M; Liang, Zhongming; Hadden, Chad E; Bandy, Steven; Kemp, Craig A; Harris, Thomas M; Baertschi, Steven W

    2013-12-06

    The availability of high performance liquid chromatography (HPLC) columns capable of operation at pH values up to 12 has allowed a greater selectivity space to be explored for method development in pharmaceutical analysis. Ammonium hydroxide is of particular value in the mobile phase because it is compatible with direct interfacing to electrospray mass spectrometers. This paper reports an unexpected N-nitrosation reaction that occurs with analytes containing primary and secondary amines when ammonium hydroxide is used to achieve the high pH and acetonitrile is used as the organic modifier. The nitrosation reaction has generality. It has been observed on multiple columns from different vendors and with multiple amine-containing analytes. Ammonia was established to be the source of the nitroso nitrogen. The stainless steel column frit and metal ablated from the frit have been shown to be the sites of the reactions. The process is initiated by removal of the chromium oxide protective film from the stainless steel by acetonitrile. It is hypothesized that the highly active, freshly exposed metals catalyze room temperature oxidation of ammonia to NO but that the actual nitrosating agent is likely N(2)O(3). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions

    Directory of Open Access Journals (Sweden)

    Ramia Z. Al Bakain

    2017-01-01

    Full Text Available Retention mechanisms involved in supercritical fluid chromatography (SFC are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase, a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition. Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns’ function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components.

  3. Hydrodynamic impact of particle shape in slurry packed liquid chromatography columns

    DEFF Research Database (Denmark)

    Lottes, F.; Arlt, W.; Minceva, M.

    2009-01-01

    We report on a series of flow velocity and efficiency profiles, which were measured across the cross section of preparative chromatographic columns packed with different stationary phase materials using computed tomography. It is shown that this non-invasive technique is very useful for visualiza...

  4. Ion chromatography for determination of nitrite and nitrate in seawater using monolithic ODS columns.

    Science.gov (United States)

    Ito, Kazuaki; Takayama, Yohichi; Makabe, Nobuyuki; Mitsui, Ryo; Hirokawa, Takeshi

    2005-08-12

    A fast and highly sensitive ion chromatographic method using monolithic ODS columns was developed for the determination of nitrite (NO2-) and nitrate (NO3-) in seawater. Two monolithic ODS columns (50 mm x 4.6 mm i.d. + 100 mm x 4.6 mm i.d.) connected in series were coated and equilibrated with 5 mM cetyltrimethylammonium chloride (CTAC) aqueous solution. The column efficiency with 0.5 M NaCl as the mobile phase did not decrease in spite of the increase in flow rate of the mobile phase. Thus, good chromatograms were obtained within 3 minutes for NO2- and NO3 in artificial seawater without interferences by coexisting ions. The detection limit (S/N = 3) with UV detection at 225 nm was 0.8 and 1.6 microg/L for NO2- and NO3-, respectively. The characteristics of the monolithic CTA(+)-coated ODS columns were discussed. The present method was successfully applied to the fast and sensitive determination of NO2- and NO3- in real seawater samples.

  5. Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography

    International Nuclear Information System (INIS)

    Catalá-Icardo, M.; Torres-Cartas, S.; Meseguer-Lloret, S.; Gómez-Benito, C.; Carrasco-Correa, E.; Simó-Alfonso, E.F.; Ramis-Ramos, G.; Herrero-Martínez, J.M.

    2017-01-01

    In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch"®), or mixtures of H_2O_2 and H_2SO_4, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the tubing wall and the stable anchorage of monolith to the wall, respectively. Special emphasis was also put on the reduction of the unwanted effects of shrinking of monolith during polymerization, by using an external proper mold and by selecting the adequate monomers in order to increase the flexibility of the polymer. Poly(glycidyl methacrylate-co-divinylbenzene) monoliths were in situ synthesized by thermal polymerization within the confines of surface-vinylized PTFE tubes. The modified PTFE tubing tightly held the monolith, and the monolithic column exhibited good pressure resistance up to 20 MPa. The column performance was also evaluated via the isocratic separation of a series of alkylbenzenes in the reversed-phase mode. The optimized monolithic columns gave plate heights ranged between 70 and 80 μm. The resulting monoliths were also satisfactorily applied to the separation of proteins. - Highlights: • Successful surface etching of PTFE inner wall tubing was done. • The modified PTFE support was next methacryloylated with GMA. • Organic polymeric monolith was in situ prepared in the functionalized PTFE tube. • The monolithic columns gave suitable pressure resistance and separation of proteins.

  6. Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Catalá-Icardo, M., E-mail: mocaic@qim.upv.es [Research Institute for Integrated Management of Coastal Areas, Universitat Politècnica de València, Paranimf 1, 46730, Grao de Gandía, Valencia (Spain); Torres-Cartas, S.; Meseguer-Lloret, S.; Gómez-Benito, C. [Research Institute for Integrated Management of Coastal Areas, Universitat Politècnica de València, Paranimf 1, 46730, Grao de Gandía, Valencia (Spain); Carrasco-Correa, E.; Simó-Alfonso, E.F.; Ramis-Ramos, G. [Department of Analytical Chemistry, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia (Spain); Herrero-Martínez, J.M., E-mail: jmherrer@uv.es [Department of Analytical Chemistry, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia (Spain)

    2017-04-01

    In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch{sup ®}), or mixtures of H{sub 2}O{sub 2} and H{sub 2}SO{sub 4}, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the tubing wall and the stable anchorage of monolith to the wall, respectively. Special emphasis was also put on the reduction of the unwanted effects of shrinking of monolith during polymerization, by using an external proper mold and by selecting the adequate monomers in order to increase the flexibility of the polymer. Poly(glycidyl methacrylate-co-divinylbenzene) monoliths were in situ synthesized by thermal polymerization within the confines of surface-vinylized PTFE tubes. The modified PTFE tubing tightly held the monolith, and the monolithic column exhibited good pressure resistance up to 20 MPa. The column performance was also evaluated via the isocratic separation of a series of alkylbenzenes in the reversed-phase mode. The optimized monolithic columns gave plate heights ranged between 70 and 80 μm. The resulting monoliths were also satisfactorily applied to the separation of proteins. - Highlights: • Successful surface etching of PTFE inner wall tubing was done. • The modified PTFE support was next methacryloylated with GMA. • Organic polymeric monolith was in situ prepared in the functionalized PTFE tube. • The monolithic columns gave suitable pressure resistance and separation of proteins.

  7. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    Science.gov (United States)

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  8. Column liquid chromatography- mass spectrometry: selected techniques in environmental applications for polar pesticides and related compounds.

    NARCIS (Netherlands)

    Slobodnik, J.; van Baar, B.L.M.; Brinkman, U.A.T.

    1995-01-01

    A review covering the field of environmental applications of liquid chromatography-mass spectrometry (LC-MS) is presented. Recent developments and advances are discussed with emphasis on the presently popular thermospray, particle beam and atmospheric pressure ionisation interfaces. Each interface

  9. Study of treatment of a thorium and rare earths residue by extraction chromatography

    International Nuclear Information System (INIS)

    Zini, Josiane; Abrao, Alcidio; Carvalho, Fatima Maria Sequeira de; Freitas, Antonio Alves de; Scapin, Marcos Antonio

    2005-01-01

    In the 70's was established at IPEN the project of a thorium compounds purification pilot plant that had the goal of fulfilling the nuclear technology purity standards. The used method was the purification by extraction with solvents in pulsed columns. The thorium remaining in the organic phase was back extracted as thorium nitrate with a high degree of purity. Impurities, thorium non-extracted and practically all rare earths in aqueous phase of this chemical process were precipitated as hydroxide, generating a product containing thorium and rare earths, that was denominated RETOTER (residue of thorium and rare earths). This residue was accumulated and today there are 25 (twenty-five) metric tons of this by product stored in the safeguard storage shed at IPEN that must to be treated due to the radiation of the thorium and mainly his daughters. The average composition of this residue is, 68% in thorium oxide (ThO 2 ), 5% in rare earths oxides (R 2 O 3 ), 0,3% in uranium oxide (U 3 O 8 ) and common impurities such as phosphorus, iron, titanium, lead and sodium. In this work a new method is presented for separation and purification of thorium from this residue, obtaining a concentrate with high degree of purity for nuclear and non-nuclear use. This process will contribute to establish a decreasing of residue volumes, to have a mind to the minimization of environmental impacts, the reduction of worker's exposition and reduction of the storage costs. In this process the separation and purification of uranium and thorium is done by chromatography extraction, being used polymeric resins, that are previously functionalized with organic solvent (extractor agent). The effluent of this process is a concentrate of rare earths that can be reprocessed in a subsequent fractionating for to obtaining the individual fractions. (author)

  10. Analysis by high-performance liquid chromatography of teucrin A in beverages flavoured with an extract of Teucrium chamaedrys L.

    Science.gov (United States)

    Bosisio, E; Giavarini, F; Dell'Agli, M; Galli, G; Galli, C L

    2004-05-01

    Due to its liver toxicity, the medicinal use of germander (Teucrium chamaedrys L.) was banned in some countries. Nevertheless, alcoholic extracts are still permitted as flavour ingredients since they are fundamental in providing a bitter aromatic taste. Teucrin A represents the substance of major concern regarding the potential toxicity of germander. Hence, teucrin A represents the best analytical and toxicological marker of alcoholic extracts of T. chamaedrys. A sensitive high-performance liquid chromatography method to detect teucrin A in beverages is reported. Teucrin A was prepared by isolation from the plant extract using column chromatography and crystallization. The identity and purity (99%) were established by melting point, nuclear magnetic resonance and liquid chromatography-mass spectrometry. The high-performance liquid chromatography procedure was validated and its intra- and interday performance was established (relative standard deviation beverages not containing T. chamaedrys spiked with a range of concentrations of teucrin A. The limit of detection was 0.1 ppm and the limit of quantification was 0.3 ppm. Teucrin A accounted for about 70% of the neo-clerodane diterpenoids found in the total extract of a specimen of T. chamaedrys. The content (+/- standard deviation) in 18 batches of different geographical origin was 2338 +/- 740 ppm, per cent coefficient of variation = 32, minimum-maximum = 999 - 3445 ppm. The mean level of teucrin A in 10 bottles of the same brand was 6.1 +/- 0.8 ppm, per cent coefficient of variation = 12. In 10 different brands found on the Italian market, the content of teucrin A ranged from not detectable to 10 ppm.

  11. Study to prepare 201Tl by irradiation of mercury with protons. Application of extraction chromatography technique in separation of thallium and mercury

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da

    1986-01-01

    The extraction chromatography technique was used for the lig and 201 Tl separation. It was used glass columns of 5,0 cm height and 1,0 cm diameter filled with Voltalef powder impregnated with TBP/cyclohexane. By the Voltalef columns solutions of 203 Hg 2+ , 201 Tl 1+ and 20 1Te 3 were separately percolated in a nitric environment of 4 to 8 M concentration and in a hydrochloridric environment of 0,5 to 4 M. The separation of Hg and 201 Tl was obtained by the retention of 201 Tl3 + in the column during the elution of all the Hg with HCl 2 M. The 201 Tl 3+ was eluted from the column after its reduction with a hot hydrazine dichloride solution. (Author) [pt

  12. Kinetic performance of a 50mm long 1.8μm chiral column in supercritical fluid chromatography.

    Science.gov (United States)

    Berger, Terry A

    2016-08-12

    Reduced plate heights (hr) of supercritical fluid chromatography (SFC). The enantiomers of trans-stilbene oxide, were separated on a 4.6×50mm, 1.8μm R,R-Whelk-O1 column, with hr as low as 1.93. The plumbing of a commercial SFC instrument was modified to create a low dispersion version. Without the modification performance was considerably worse. vanDeemter like plots of reduced plate height vs. flow rate, for trans-stilbene oxide, indicate that the optimum flow varied with% modifier. On a 4.6×250mm, 5μm R,R- Whelk-O1 column, the optimum flow was >4mL/min for 5% methanol in CO2, decreasing to 5mL/min with 2.5%, 5%, and 10% methanol, decreasing to between 3 and 3.5mL/min at 40% methanol. This is the first time such shifts have been characterized. Since the solutes were the same in all cases, the differences are likely due to changes in solute diffusion coefficients caused by changes in modifier concentration, and pressure. Pump pressure requirements sometimes exceeded 500bar. It is shown that a 5mL/min flow rate is inadequate for use with 1.8μm particles in a 4.6mm ID column format. Instead, it is suggested to decrease the ID of the column to 3mm, where the optimum flow rates are on the order of 2mL/min with decreased tubing variance. Nevertheless, a number of sub-1min chromatograms are presented. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Extending the upper temperature range of gas chromatography with all-silicon microchip columns using a heater/clamp assembly.

    Science.gov (United States)

    Ghosh, Abhijit; Johnson, Jacob E; Nuss, Johnathan G; Stark, Brittany A; Hawkins, Aaron R; Tolley, Luke T; Iverson, Brian D; Tolley, H Dennis; Lee, Milton L

    2017-09-29

    Miniaturization of gas chromatography (GC) instrumentation is of interest because it addresses current and future issues relating to compactness, portability and field application. While incremental advancements continue to be reported in GC with columns fabricated in microchips (referred to in this paper as "microchip columns"), the current performance is far from acceptable. This lower performance compared to conventional GC is due to factors such as pooling of the stationary phase in corners of non-cylindrical channels, adsorption of sensitive compounds on incompletely deactivated surfaces, shorter column lengths and less than optimum interfacing to injector and detector. In this work, a GC system utilizing microchip columns was developed that solves the latter challenge, i.e., microchip interfacing to injector and detector. A microchip compression clamp was constructed to heat the microchip (i.e., primary heater), and seal the injector and detector fused silica interface tubing to the inlet and outlet ports of the microchip channels with minimum extra-column dead volume. This clamp allowed occasional operation up to 375°C and routine operation up to 300°C. The compression clamp was constructed of a low expansion alloy, Kovar™, to minimize leaking due to thermal expansion mismatch at the interface during repeated thermal cycling, and it was tested over several months for more than one hundred injections without forming leaks. A 5.9m long microcolumn with rectangular cross section of 158μm×80μm, which approximately matches a 100μm i.d. cylindrical fused silica column, was fabricated in a silicon wafer using deep reactive ion etching (DRIE) and high temperature fusion bonding; finally, the channel was coated statically with a 1% vinyl, 5% phenyl, 94% methylpolysiloxane stationary phase. High temperature separations of C10-C40 n-alkanes and a commercial diesel sample were demonstrated using the system under both temperature programmed GC (TPGC) and thermal

  14. Bridged polysilsesquioxane-based wide-bore monolithic capillary columns for hydrophilic interaction chromatography

    Czech Academy of Sciences Publication Activity Database

    Šesták, Jozef; Moravcová, Dana; Křenková, Jana; Planeta, Josef; Roth, Michal; Foret, František

    2017-01-01

    Roč. 1479, JAN (2017), s. 204-209 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA14-06319S; GA ČR(CZ) GA16-03749S Institutional support: RVO:68081715 Keywords : silica monolithic column * HILIC * oligosaccharides * nucleosides Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 3.981, year: 2016

  15. A new purity criterion for α- and β-cyclodextrin using partition chromatography on cellulose columns

    NARCIS (Netherlands)

    Lammers, J.N.J.J.

    1967-01-01

    In order to check the purity of a- and b-cyclodextrins with respect to each other partition chromatog. on cellulose columns was used (elution with 42:29:29 BuOH-EtOH-H2O, 0.3 atm. air pressure on the solvent reservoir; 75-90 ml./hr. flow rate). Amts. down to 2.5% a-cyclodextrin (I) in b-cyclodextrin

  16. Zwitterionic silica-based monolithic capillary columns for isocratic and gradient hydrophilic interaction liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Moravcová, Dana; Planeta, Josef; Kahle, Vladislav; Roth, Michal

    2012-01-01

    Roč. 1270, DEC 28 (2012), s. 178-185 ISSN 0021-9673 R&D Projects: GA MV VG20112015021; GA ČR(CZ) GAP206/11/0138; GA ČR(CZ) GAP106/12/0522 Institutional support: RVO:68081715 Keywords : HILIC * Monolithic silica column * Nucleoside separation * Nucleic acid base Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.612, year: 2012

  17. Assay of fluconazole by high-performance liquid chromatography with a mixed-phase column.

    OpenAIRE

    Wallace, J E; Harris, S C; Gallegos, J; Foulds, G; Chen, T J; Rinaldi, M G

    1992-01-01

    A mixed-phase liquid chromatographic column was used to assay fluconazole in plasma, serum, and cerebrospinal fluid. The assay was linear from 0.2 to 20 micrograms/ml, with an average coefficient of variation of less than 5%. The partitioning of the drug between serum and cerebrospinal fluid was determined for 34 patients. The method was demonstrated to be suitable for both pharmacokinetic studies and monitoring of patients receiving treatment with this antifungal agent.

  18. Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview.

    Science.gov (United States)

    Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M

    2015-11-20

    The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. 67 Ga and Zn separation by column chromatography using organic adsorbent

    International Nuclear Information System (INIS)

    Santos, Eliane E. dos; Mestnik, Sonia Ap. C.

    1995-01-01

    The radioisotope 67 Ga is widely used in nuclear medicine for detecting the presence of malignancy and for diagnosis of inflammatory diseases due to its suitable physical characteristics such as half-life of 78 h and γ-rays of 93 KeV(38%), 184(KeV(24%), 296 KeV(22%) and 388 KeV(4%). In this work we present the separation of 67 Ga from Zn using SM-7 (Bio Rad) as absorbent. After setting up the best experimental condition for the absorption of 67 Ga on the chromatographic column the volume of solution to remove all metal contaminants from this column was determined. A characteristic elution curve is also presented. From the studies carried out it was shown that 15,0 ml of 7,0 M HCL were sufficient to remove all contaminants from the column and also that 7,0 ml of 0,01 M HCL were enough to elute all 67 Ga. The 67 Ga separation yield was around 93%. (author). 4 refs., 1 fig

  20. Determination of free sulfites (SO3-2) in dried fruits processed with sulfur dioxide by ion chromatography through anion exchange column and conductivity detection.

    Science.gov (United States)

    Liao, Benjamin S; Sram, Jacqueline C; Files, Darin J

    2013-01-01

    A simple and effective anion ion chromatography (IC) method with anion exchange column and conductivity detector has been developed to determine free sulfites (SO3-2) in dried fruits processed with sulfur dioxide. No oxidation agent, such as hydrogen peroxide, is used to convert sulfites to sulfates for IC analysis. In addition, no stabilizing agent, such as formaldehyde, fructose or EDTA, is required during the sample extraction. This method uses aqueous 0.2 N NaOH as the solvent for standard preparation and sample extraction. The sulfites, either prepared from standard sodium sulfite powder or extracted from food samples, are presumed to be unbound SO3-2 in aqueous 0.2 N NaOH (pH > 13), because the bound sulfites in the sample matrix are released at pH > 10. In this study, sulfites in the standard solutions were stable at room temperature (i.e., 15-25 degrees C) for up to 12 days. The lowest standard of the linear calibration curve is set at 1.59 microg/mL SO3-2 (equivalent to 6.36 microg/g sample with no dilution) for analysis of processed dried fruits that would contain high levels (>1000 microg/g) of sulfites. As a consequence, this method typically requires significant dilution of the sample extract. Samples are prepared with a simple procedure of sample compositing, extraction with aqueous 0.2 N NaOH, centrifugation, dilution as needed, and filtration prior to IC. The sulfites in these sample extracts are stable at room temperature for up to 20 h. Using anion IC, the sulfites are eluted under isocratic conditions with 10 mM aqueous sodium carbonate solution as the mobile phase passing through an anion exchange column. The sulfites are easily separated, with an analysis run time of 18 min, regardless of the dried fruit matrix. Recoveries from samples spiked with sodium sulfites were demonstrated to be between 81 and 105% for five different fruit matrixes (apricot, golden grape, white peach, fig, and mango). Overall, this method is simple to perform and

  1. Automatic collection of the rare-earths with post chromatography column detection

    International Nuclear Information System (INIS)

    David, P.; Metzger, G.; Repellin, M.

    1987-01-01

    The complete separation of rare-earths (in the aim of radio-isotopes measurement) requires High Performance Liquid Chromatography with ternary elution gradient. To automatize their collection with satisfying conditions, we have realized a non polluting, reliable and easy to operate detection method. This one is based on a derivation colorimetric system with arsenazo I (3 -(2 arsophenylazo 4.5) - dihydroxy - 2.7 naphtalene disulfonic acid)

  2. A simple, fast, and accurate thermodynamic-based approach for transfer and prediction of gas chromatography retention times between columns and instruments Part III: Retention time prediction on target column.

    Science.gov (United States)

    Hou, Siyuan; Stevenson, Keisean A J M; Harynuk, James J

    2018-03-27

    This is the third part of a three-part series of papers. In Part I, we presented a method for determining the actual effective geometry of a reference column as well as the thermodynamic-based parameters of a set of probe compounds in an in-house mixture. Part II introduced an approach for estimating the actual effective geometry of a target column by collecting retention data of the same mixture of probe compounds on the target column and using their thermodynamic parameters, acquired on the reference column, as a bridge between both systems. Part III, presented here, demonstrates the retention time transfer and prediction from the reference column to the target column using experimental data for a separate mixture of compounds. To predict the retention time of a new compound, we first estimate its thermodynamic-based parameters on the reference column (using geometric parameters determined previously). The compound's retention time on a second column (of previously determined geometry) is then predicted. The models and the associated optimization algorithms were tested using simulated and experimental data. The accuracy of predicted retention times shows that the proposed approach is simple, fast, and accurate for retention time transfer and prediction between gas chromatography columns. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Separation of amino acids and antibiotics by narrow-bore and normal-bore high-performance liquid chromatography with pre-column derivatization.

    Science.gov (United States)

    Fiedler, H P; Plaga, A

    1987-01-16

    The selectivity, efficiency and lifetime of normal- and narrow-bore columns for high-performance liquid chromatography were investigated for the separation and quantification of amino acids and the amino acid-like antibiotics phosphinothricin and phosphinothricylalanylalanine in biological samples. These compounds were determined by an automated pre-column derivatization with o-phthalaldehyde-2-mercaptoethanol reagent and UV detection at 338 nm.

  4. Simultaneous determination of 3-monochloropropane-1,2-diol and acrylamide in food by gas chromatography-triple quadrupole mass spectrometry with coupled column separation.

    Science.gov (United States)

    Xu, Xiao-min; He, Hua-li; Zhu, Yan; Feng, Liang; Ying, Ying; Huang, Bai-fen; Shen, Hai-tao; Han, Jian-long; Ren, Yi-ping

    2013-01-14

    Both 3-monochloropropane-1,2-diol (3-MCPD) and acrylamide are contaminants found in heat-processed foods and their related products. A quantitative method was developed for the simultaneous determination of both contaminants in food by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). The analytes were purified and extracted by the matrix solid-phase dispersion extraction (MSPDE) technique with Extrelut NT. A coupled column (a 3 m Innowax combined with a 30 m DB-5 ms) was developed to separate both compounds efficiently without derivatization. Triple quadrupole mass spectrometry in multiple reaction monitoring mode (MRM) was applied to suppress matrix interference and obtain good sensitivity in the determination of both analytes. The limit of detection (LOD) in the sample matrix was 5 μg kg(-1) for 3-MCPD or acrylamide. The average recoveries for 3-MCPD and acrylamide in different food matrices were 90.5-107% and 81.9-95.7%, respectively, with the intraday relative standard deviations (RSDs) of 5.6-13.5% and 5.3-13.4%, respectively. The interday RSDs were 6.1-12.6% for 3-MCPD and were 5.0-12.8% for acrylamide. Both contaminants were found in samples of bread, fried chips, fried instant noodles, soy sauce, and instant noodle flavoring. Neither 3-MCPD nor acrylamide was detected in the samples of dairy products (solid or liquid samples) and non-fried instant noodles. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Speciation of mercury by ion chromatography with post-column derivatization

    International Nuclear Information System (INIS)

    Foltin, M.; Megova, S.; Prochakova, T.; Steklac, M.

    1996-01-01

    The chromatographic behaviour of Hg(II), methylmercury, phenylmercury and Cu(II) on three different sorbents, strong acidic sulfobutyl cation-exchanger, weak basic aminopropyl anion-exchanger and silicagel has been studied. A dithizone solution in cetyltrimethylammonium hydrogensulfate water micellar medium was found as a useful post-column derivatization reagent for UV-VIS detection. The detection limits 1.1 ng, 2.2 ng, 6.2 ng and 1.6 ng were found in silicagel chromatographic system and dithizone detection system for Hg(II), methylmercury, phenylmercury and respectively for Cu(II). (author). 18 refs., 4 figs., 3 tabs

  6. The status of research on CFD-PBM simulation of liquid-liquid two-phase flow in extraction columns

    International Nuclear Information System (INIS)

    Li Shaowei; Jing Shan; Wu Qiulin; Zhang Qi

    2012-01-01

    Computational fluid dynamics (CFD) simulation has gained more and more interest in the chemical engineering researchers and is becoming a useful tool for the chemical engineering research. The research on liquid-liquid two-phase flow CFD simulation in extraction columns is now in its initial stage. There is much work to do for the developing of this research field. The purpose of this article is to review the CFD simulation methods for two-phase flow in extraction column. The population balance model (PBM) is detailedly described in this article because it is the main method used in the two-phase flow CFD simulation currently. Then some examples for the two-phase flow simulation in extraction columns are briefly introduced. The strategy for the research on CFD simulation of two-phase flow in extraction columns is suggested at last. (authors)

  7. Preparation of acryloyl β-cyclodextrin-silica hybrid monolithic column and its application in pipette tip solid-phase extraction and HPLC analysis of methyl parathion and fenthion.

    Science.gov (United States)

    Chen, Ling; Dang, Xueping; Ai, Youhong; Chen, Huaixia

    2018-05-07

    An acryloyl β-cyclodextrin-silica hybrid monolithic column for pipette tip solid-phase extraction and high-performance liquid chromatography determination of methyl parathion and fenthion have been prepared through a sol-gel polymerization method. The synthesis conditions, including the volume of cross-linker and the ratio of inorganic solution to organic solution, were optimized. The prepared monolithic column was characterized by thermogravimetric analysis, scanning electron microscopy and Fourier transform infrared spectroscopy. The eluent type, volume and flow rate, sample volume, flow rate, acidity and ionic strength were optimized in detail. Under the optimized conditions, a simple and sensitive pipette tip solid-phase extraction with high-performance liquid chromatography method was developed for the determination of methyl parathion and fenthion in lettuce. The method yielded a linear calibration curve in the concentration ranges of 15-400 μg/kg for methyl parathion and 20-400 μg/kg for fenthion with correlation coefficients of above 0.9957. The limits of detection were 4.5 μg/kg for methyl parathion and 6.0 μg/kg for fenthion, respectively. The recoveries of methyl parathion and fenthion spiked in lettuce ranged from 96.0 to 104.2% with relative standard deviations less than 8.4%. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Utilizing ion-pairing hydrophilic interaction chromatography solid phase extraction for efficient glycopeptide enrichment in glycoproteomics

    DEFF Research Database (Denmark)

    Mysling, Simon; Palmisano, Giuseppe; Højrup, Peter

    2010-01-01

    Glycopeptide enrichment is a prerequisite to enable structural characterization of protein glycosylation in glycoproteomics. Here we present an improved method for glycopeptide enrichment based on zwitter-ionic hydrophilic interaction chromatography solid phase extraction (ZIC-HILIC SPE...

  9. Modeling retention and selectivity as a function of pH and column temperature in liquid chromatography.

    Science.gov (United States)

    Gagliardi, Leonardo G; Castells, Cecilia B; Ràfols, Clara; Rosés, Martí; Bosch, Elisabeth

    2006-08-15

    In reversed-phase liquid chromatography (RPLC), the retention of weak acids and bases is a sigmoidal function of the mobile-phase pH. Therefore, pH is a key chromatographic variable to optimize retention and selectivity. Furthermore, at an eluent pH close to the pKa of the solute, the dependence of ionization of the buffer and solute on temperature can be used to improve chromatographic separations involving ionizable solutes by an adequate handling of column temperature. In this paper, we derive a general equation for the prediction of the retentive behavior of ionizable compounds upon simultaneous changes in mobile-phase pH and column temperature. Four experiments, two limiting pH values and two temperatures, provide the input data that allow predictions in the whole range of these two variables, based on the thermodynamic fundamentals of the involved equilibria. Also, the study demonstrates the significant role that the choice of the buffer compound would have on selectivity factors in RPLC at temperatures higher than 25 degrees C.

  10. Column Chromatography Of Co(II), Zn(II) And Eu(III) Using Pistachio Shell And Different Mobile Phases

    International Nuclear Information System (INIS)

    Abdel-Fattah, A.A.

    2009-01-01

    Pistachio shell particles (0.5-1 mm) have been applied as the stationary phase for studying the column chromatography of Co(II), Zn(II) and Eu(III) at room temperature; 26 + - 1 oC. This solid sorbent has been characterized by thermogravimetric analysis, infra-red spectroscopy and X-ray diffraction. Its surface area and percent of swelling have been also determined. Different eluting agents have been used for eluting the sorbed elements. The elution curves have been done from which the distribution coefficients (K d ), number of theoretical plates (N) and heights equivalent to theoretical plates (H) have been determined. Column performance studies have been conducted for a representative system under certain experimented conditions and Van Deemter equation has been applied. Thermodynamic studies have been applied and thermodynamic functions ( δG 0 ,δH 0 andδ S 0 ) have been calculated for this representative system by determining K d at three different room temperatures (18, 26 and 37 + - 1o C).

  11. Column Chromatography Of Co(II), Zn(II) And Eu(III) Using Pistachio Shell And Different Mobile Phases

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Fattah, A A [Nuclear Chemistry Department, Radioisotopes Production Division, Hot Laboratories Centre, Atomic Energy Authority, Cairo (Egypt)

    2009-07-01

    Pistachio shell particles (0.5-1 mm) have been applied as the stationary phase for studying the column chromatography of Co(II), Zn(II) and Eu(III) at room temperature; 26{sup +}-{sup 1}oC. This solid sorbent has been characterized by thermogravimetric analysis, infra-red spectroscopy and X-ray diffraction. Its surface area and percent of swelling have been also determined. Different eluting agents have been used for eluting the sorbed elements. The elution curves have been done from which the distribution coefficients (K{sub d}), number of theoretical plates (N) and heights equivalent to theoretical plates (H) have been determined. Column performance studies have been conducted for a representative system under certain experimented conditions and Van Deemter equation has been applied. Thermodynamic studies have been applied and thermodynamic functions ( {delta}G{sup 0} ,{delta}H{sup 0} and{delta} S{sup 0}) have been calculated for this representative system by determining K{sub d} at three different room temperatures (18, 26 and 37{sup +}-{sup 1o}C)

  12. Analysis of trace inorganic anions in weak acid salts by single pump cycling-column-switching ion chromatography.

    Science.gov (United States)

    Huang, Zhongping; Ni, Chengzhu; Zhu, Zhuyi; Pan, Zaifa; Wang, Lili; Zhu, Yan

    2015-05-01

    The application of ion chromatography with the single pump cycling-column-switching technique was described for the analysis of trace inorganic anions in weak acid salts within a single run. Due to the hydrogen ions provided by an anion suppressor electrolyzing water, weak acid anions could be transformed into weak acids, existing as molecules, after passing through the suppressor. Therefore, an anion suppressor and ion-exclusion column were adopted to achieve on-line matrix elimination of weak acid anions with high concentration for the analysis of trace inorganic anions in weak acid salts. A series of standard solutions consisting of target anions of various concentrations from 0.005 to 10 mg/L were analyzed, with correlation coefficients r ≥ 0.9990. The limits of detection were in the range of 0.67 to 1.51 μg/L, based on the signal-to-noise ratio of 3 and a 25 μL injection volume. Relative standard deviations for retention time, peak area, and peak height were all less than 2.01%. A spiking study was performed with satisfactory recoveries between 90.3 and 104.4% for all anions. The chromatographic system was successfully applied to the analysis of trace inorganic anions in five weak acid salts. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  14. Simultaneous column chromatographic extraction and purification of abscisic acid in peanut plants for direct HPLC analysis.

    Science.gov (United States)

    Zhang, Ya-Wen; Fan, Wei-Wei; Li, Hui; Ni, He; Han, Han-Bing; Li, Hai-Hang

    2015-10-01

    Abscisic acid (ABA), a universal signaling molecule, plays important roles in regulating plant growth, development and stress responses. The low contents and complex components in plants make it difficult to be accurately analyzed. A novel one-step sample preparation method for ABA in plants was developed. Fresh peanut (Arachis hypogaea) plant materials were fixed by oven-drying, microwave drying, boiling or Carnoy's fixative, and loaded onto a mini-preparing column. After washed the impurities, ABA was eluted with a small amount of solvent. ABA in plant materials was completely extracted and purified in 2mL solution and directly analyzed by HPLC, with a 99.3% recovery rate. Multiple samples can be simultaneously prepared. Analyses using this method indicated that the endogenous ABA in oven-dried peanut leaves increased 20.2-fold from 1.01 to 20.37μgg(-1) dry weight within 12h and then decreased in 30% polyethylene glycol 6000 treated plants, and increased 3.34-fold from 0.85 to 2.84μgg(-1) dry weight in 5 days and then decreased in soil drought treated plants. The method combined the column chromatographic extraction and solid-phase separation technologies in one step and can completely extracted plant endogenous ABA in a purified and highly concentrated form for direct HPLC analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Closed-loop optimization of chromatography column sizing strategies in biopharmaceutical manufacture.

    Science.gov (United States)

    Allmendinger, Richard; Simaria, Ana S; Turner, Richard; Farid, Suzanne S

    2014-10-01

    This paper considers a real-world optimization problem involving the identification of cost-effective equipment sizing strategies for the sequence of chromatography steps employed to purify biopharmaceuticals. Tackling this problem requires solving a combinatorial optimization problem subject to multiple constraints, uncertain parameters, and time-consuming fitness evaluations. An industrially-relevant case study is used to illustrate that evolutionary algorithms can identify chromatography sizing strategies with significant improvements in performance criteria related to process cost, time and product waste over the base case. The results demonstrate also that evolutionary algorithms perform best when infeasible solutions are repaired intelligently, the population size is set appropriately, and elitism is combined with a low number of Monte Carlo trials (needed to account for uncertainty). Adopting this setup turns out to be more important for scenarios where less time is available for the purification process. Finally, a data-visualization tool is employed to illustrate how user preferences can be accounted for when it comes to selecting a sizing strategy to be implemented in a real industrial setting. This work demonstrates that closed-loop evolutionary optimization, when tuned properly and combined with a detailed manufacturing cost model, acts as a powerful decisional tool for the identification of cost-effective purification strategies. © 2013 The Authors. Journal of Chemical Technology & Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.

  16. Determination of tiamulin in type C medicated swine feeds using high throughput extraction with liquid chromatography.

    Science.gov (United States)

    Moore, Douglas B; Britton, Nanc L; Smallidge, Robert L; Riter, Ken L

    2002-01-01

    An improved method for extraction and analysis of tiamulin is presented to address issues that arose during routine analysis of Type C medicated swine feeds under the current U.S. Food and Drug Administration-Center for Veterinary Medicine (FDA-CVM) approved method. The issues included the need for higher sample throughput and the ability to accommodate a wider variety of feed matrixes. Changes to the FDA-CVM approved method include reduced sample size and solvent volumes, phosphate buffering of tartaric acid, centrifugation, and use of a new liquid chromatography column and adjusted mobile phase composition. A paired sample study was performed to compare performance of the new and existing methods. The paired sample study showed no statistical difference between sample means of paired sets of 17 samples analyzed by both methods (t = 1.95 at 0.05 significance level, p = 0.068). A recovery study showed the method precision to be 2.06% (coefficient of variation) with an average standard recoveryof 95.8%. Ruggedness test results indicated good overall ruggedness of the method.

  17. Identification and fingerprinting of biodiesel blends by solid phase extraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Z. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Section, Emergencies, Operational Analytical Laboratories and Research Support Division; China Univ. of Geosciences, Wuhan (China). School of Environmental Studies; Hollebone, B.; Wang, Z.; Yang, C.; Landriault, M. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Section, Emergencies, Operational Analytical Laboratories and Research Support Division

    2009-07-01

    Interest in biodiesel as a replacement for petroleum diesel fuel is growing. In North America, biodiesels are produced by the methyl esterification of plant and animal triglycerides, resulting in complex mixtures composed of fatty acid methyl esters (FAMEs). It is important for both environmental forensic and remediation purposes to determine diesel and biodiesel origins, and the biodiesel content when it is blended with conventional petroleum diesel. This paper reported on a study that combined 2 methods to determine biodiesel levels in blended fuels. Micro-column fractionation of FAMEs involving solid phase extraction (SPE) was combined with gas chromatography-mass spectrometry (GC/MS) to achieve detailed chemical fingerprinting of blends, including the identification and quantification of individual aliphatic hydrocarbons, aromatic hydrocarbons, fatty acid alkyl esters, and free sterols. Fractionation of the fuel samples was optimized for separation of fatty acid esters, free sterols from petroleum hydrocarbons into 4 fractions, notably aliphatic, aromatic, fatty-acid ester and polar components. A sum of the FAME components was used to determine an unknown blend level in freshly-prepared samples. This study showed that this method has great potential for identifying biodiesel in diesel fuel blends and could form the basis of a method for biodiesel-contaminated environmental samples. 28 refs., 5 tabs., 4 figs.

  18. Identification and fingerprinting of biodiesel blends by solid phase extraction and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Yang, Z.; China Univ. of Geosciences, Wuhan; Hollebone, B.; Wang, Z.; Yang, C.; Landriault, M.

    2009-01-01

    Interest in biodiesel as a replacement for petroleum diesel fuel is growing. In North America, biodiesels are produced by the methyl esterification of plant and animal triglycerides, resulting in complex mixtures composed of fatty acid methyl esters (FAMEs). It is important for both environmental forensic and remediation purposes to determine diesel and biodiesel origins, and the biodiesel content when it is blended with conventional petroleum diesel. This paper reported on a study that combined 2 methods to determine biodiesel levels in blended fuels. Micro-column fractionation of FAMEs involving solid phase extraction (SPE) was combined with gas chromatography-mass spectrometry (GC/MS) to achieve detailed chemical fingerprinting of blends, including the identification and quantification of individual aliphatic hydrocarbons, aromatic hydrocarbons, fatty acid alkyl esters, and free sterols. Fractionation of the fuel samples was optimized for separation of fatty acid esters, free sterols from petroleum hydrocarbons into 4 fractions, notably aliphatic, aromatic, fatty-acid ester and polar components. A sum of the FAME components was used to determine an unknown blend level in freshly-prepared samples. This study showed that this method has great potential for identifying biodiesel in diesel fuel blends and could form the basis of a method for biodiesel-contaminated environmental samples. 28 refs., 5 tabs., 4 figs.

  19. Approximate transient and long time limit solutions for the band broadening induced by the thin sidewall-layer in liquid chromatography columns.

    Science.gov (United States)

    Broeckhoven, Ken; Desmet, Gert

    2007-11-16

    Using a combination of both analytical and numerical techniques, approximate analytical expressions have been established for the transient and long time limit band broadening, originating from the presence of a thin disturbed sidewall layer in liquid chromatography columns, including packed, monolithic as well as microfabricated columns. The established expressions can be used to compare the importance of a thin disturbed sidewall layer with that of other radial heterogeneity effects (such as transcolumn packing density variations due to the relief of packing stresses). The expressions are independent of the actual velocity profile inside the layer as long as the disturbed sidewall layer occupies less than 2.5% of the column width.

  20. Rapid determination of glyphosate in cereal samples by means of pre-column derivatisation with 9-fluorenylmethyl chloroformate and coupled-column liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Hogendoorn, E A; Ossendrijver, F M; Dijkman, E; Baumann, R A

    1999-02-12

    A rapid procedure for the determination of glyphosate in cereals has been developed. Convenient sample pretreatment is carried out by (i) a overnight standing extraction of 1.0 g homogenized sample with 20 ml of water, (ii) centrifugation of the samples, (iii) a passing of 2.5 ml of the clear layer through a 100 mg C18 solid-phase extraction cartridge and (iv) collection of the last 1.5 ml of the eluent into a calibrated tube. For the instrumental analysis, the efficient approach developed earlier for environmental water samples [J.V. Sancho, F. Hernández, F.J. LUpez, E.A. Hogendoorn, E. Dijkman, P. van Zoonen, J. Chromatogr. A, 737 (1996) 75] was successfully adopted for the determination of glyphosate in the obtained cereal extracts. The procedure includes a 15 min derivatisation step of the analyte with 9-fluorenylmethyl chloroformate and a 16 times dilution step prior to instrumental analysis employing coupled-column LC with fluorescence detection. The developed procedure has a sample throughput of more than 25 samples per day and a limit of quantification of 0.5 mg/kg. The method was validated by analyzing freshly spiked cereal samples and samples with aged residues at levels between 1.0 and 10 mg/kg. The overall recovery of the freshly spiked samples was 86% (n = 10) with a repeatability of 6.5% and a reproducibility of 9.5%. For samples with aged residues recoveries performed at different time intervals (range 80-150 days) did not differ significantly; the overall recovery (n = 10) was 74% with a repeatability and reproducibility of 14 and 20%, respectively.

  1. Chip-based molecularly imprinted monolithic capillary array columns coated GO/SiO2 for selective extraction and sensitive determination of rhodamine B in chili powder.

    Science.gov (United States)

    Zhai, Haiyun; Huang, Lu; Chen, Zuanguang; Su, Zihao; Yuan, Kaisong; Liang, Guohuan; Pan, Yufang

    2017-01-01

    A novel solid-phase extraction chip embedded with array columns of molecularly imprinted polymer-coated silanized graphene oxide (GO/SiO2-MISPE) was established to detect trace rhodamine B (RB) in chili powder. GO/SiO2-MISPE monolithic columns for RB detection were prepared by optimizing the supporting substrate, template, and polymerizing monomer under mild water bath conditions. Adsorption capacity and specificity, which are critical properties for the application of the GO/SiO2-MISPE monolithic column, were investigated. GO/SiO2-MIP was examined by scanning electron microscopy (SEM) and Fourier transform-infrared spectroscopy. The recovery and the intraday and interday relative standard deviations for RB ranged from 83.7% to 88.4% and 2.5% to 4.0% and the enrichment factors were higher than 110-fold. The chip-based array columns effectively eliminated impurities in chili powder, indicating that the chip-based GO/SiO2-MISPE method was reliable for RB detection in food samples using high-performance liquid chromatography. Accordingly, this method has direct applications for monitoring potentially harmful dyes in processed food. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. A novel approach to the simultaneous extraction and non-targeted analysis of the small molecules metabolome and lipidome using 96-well solid phase extraction plates with column-switching technology.

    Science.gov (United States)

    Li, Yubo; Zhang, Zhenzhu; Liu, Xinyu; Li, Aizhu; Hou, Zhiguo; Wang, Yuming; Zhang, Yanjun

    2015-08-28

    This study combines solid phase extraction (SPE) using 96-well plates with column-switching technology to construct a rapid and high-throughput method for the simultaneous extraction and non-targeted analysis of small molecules metabolome and lipidome based on ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry. This study first investigated the columns and analytical conditions for small molecules metabolome and lipidome, separated by an HSS T3 and BEH C18 columns, respectively. Next, the loading capacity and actuation duration of SPE were further optimized. Subsequently, SPE and column switching were used together to rapidly and comprehensively analyze the biological samples. The experimental results showed that the new analytical procedure had good precision and maintained sample stability (RSDmetabolome and lipidome to test the throughput. The resulting method represents a new analytical approach for biological samples, and a highly useful tool for researches in metabolomics and lipidomics. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Single-column extraction chromatographic separation of U, Pu, Np and Am

    Energy Technology Data Exchange (ETDEWEB)

    Morgenstern, A.; Apostolidis, C.; Carlos-Marquez, R.; Mayer, K.; Molinet, R. [Commission of the European Communities, Karlsruhe (Germany). European Inst. for Transuranium Elements

    2002-07-01

    A rapid, single-column extraction chromatographic method using commercially available UTEVA resin has been developed for the separation of uranium, plutonium, neptunium and americium. The method yields recoveries superior to 90% and allows direct loading of separated fractions on filaments for subsequent analysis by thermal ionization mass spectrometry. The use of reagents compatible with robotized equipment allows automation of the separation process for routine analysis of nuclear materials. The redox reactions between plutonium, neptunium and hydrogen peroxide involved in the separation process were studied by UV/Vis/NIR absorption spectroscopy. (orig.)

  4. Long-chain alkylimidazolium ionic liquids, a new class of cationic surfactants coated on ODS columns for anion-exchange chromatography.

    Science.gov (United States)

    Qiu, Hongdeng; Zhang, Qinghua; Chen, Limei; Liu, Xia; Jiang, Shengxiang

    2008-08-01

    Separations of common inorganic anions were carried out on ODS columns coated with two long-chain alkylimidazolium ionic liquids ([C(12)MIm]Br and [C(14)MIm]Br) as new cationic surfactants for ion chromatography. With phthalate buffer solution as the mobile phases and non-suppressed conductivity detection, high column efficiencies and excellent selectivity were obtained in the separation of inorganic anions. Chromatographic parameters are calculated and the results show that the coated column possesses significant potential for the analysis of some inorganic anions such as CH(3)COO(-), IO(3)(-), Cl(-), BrO(3)(-), NO(2)(-), Br(-), NO(3)(-), SO(4)(2-), I(-), BF(4)(-), and SCN(-). The effect of eluent pH values on the separation of anions has been studied on the column coated with [C(12)MIm]Br. The stability of the coated columns was also examined.

  5. [Simultaneous determination of 15 industrial synthetic dyes in condiment by solid phase extraction-high performance liquid chromatography].

    Science.gov (United States)

    Liu, Min; Li, Xiaolin; Bie, Wei; Wang, Minglin; Feng, Qian

    2011-02-01

    A new method was established for the determination of 15 industrial synthetic dyes in condiment by solid phase extraction-high performance liquid chromatography (SPE-HPLC). The samples were extracted by methanol-water (1:1, v/v) and purified by a solid phase extraction column. Then, the chromatographic separation was achieved on a Luna C18 column by linear gradient elution. The mobile phase was 10 mmol/L ammonium acetate-acetonitrile (containing 1% acetic acid). The results showed that the 15 industrial synthetic dyes can be separated efficiently. The recoveries of the 15 industrial synthetic dyes spiked in condiment were between 84.6% and 114.2% with the relative standard deviations of 0.9% - 10.3%. The limits of detection of this method was 0.05 - 0.18 mg/kg for the 15 industrial synthetic dyes. The method is simple, sensitive, accurate, repeatable and can be used for simultaneous determination of the 15 illegally added industrial synthetic dyes.

  6. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection

    International Nuclear Information System (INIS)

    Nakamoto, Akihiro; Nishida, Manami; Saito, Takeshi; Kishiyama, Izumi; Miyazaki, Shota; Murakami, Katsunori; Nagao, Masataka; Namura, Akira

    2010-01-01

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d 5 was used as an internal standard. The linear ranges were 0.01-5.0 μg mL -1 for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 μg mL -1 for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation ≥0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 μg mL -1 of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio ≥ 3) in urine was 5 ng mL -1 for MA and MDMA and 10 ng mL -1 for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.

  7. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    Science.gov (United States)

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-05-01

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL -1 (LOQ) to 6 ng mL -1 for AEA and from 0.04 ng mL -1 (LOQ) to 10 ng mL -1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.

  8. Simultaneous determination of hydroxycinnamates and catechins in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Sandström, B.

    2003-01-01

    A quantitative liquid chromatography mass spectrometry (LC-MS) methodology with online sample clean up by column switching is described for the simultaneous determination of the hydroxycinnamates, caffeic acid and chlorogenic acid, and of the catechins, epicatechin and catechin in human urine...

  9. Determination of citrus limonoid glucosides by high performance liquid chromatography coupled to post-column reaction with Ehrlich’s Reagent

    Science.gov (United States)

    A method for the identification and quantification of citrus limonoid glucosides in juices based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlichs’s reagent has been developed. This method utilizes a phenyl stationary phase and an isocratic ...

  10. Selective on-line detection of boronic acids and derivatives in high-performance liquid chromatography eluates by post-column reaction with alizarin

    NARCIS (Netherlands)

    Duval, F.L.; Wardani, P.A.; Zuilhof, H.; Beek, van T.A.

    2015-01-01

    An on-line high-performance liquid chromatography (HPLC) method for the rapid and selective detection of boronic acids in complex mixtures was developed. After optimization experiments at an HPLC flow rate of 0.40 mL/min, the HPLC-separated analytes were mixed post-column with a solution of 75 µM

  11. Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography.

    Science.gov (United States)

    Lhotská, Ivona; Holznerová, Anežka; Solich, Petr; Šatínský, Dalibor

    2017-12-01

    Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Three column intermittent simulated moving bed chromatography: 3. Cascade operation for center-cut separations.

    Science.gov (United States)

    Jermann, Simon; Meijssen, Mattheus; Mazzotti, Marco

    2015-01-23

    A general design methodology for chromatographic three fraction separation by application of the three column intermittent simulated moving bed (3C-ISMB) cascade is proposed and experimentally validated by studying the purification of an intermediately retained stereoisomer of nadolol, from an equimolar mixture of its four stereoisomers. The theoretical part shows that the 3C-ISMB cascade can be easily designed by applying Triangle Theory. Moreover, a re-scaling approach for the second stage is proposed so as to account for the fact that the feed flow rates to stage 2 are generally higher as compared to stage 1 due to dilution in the latter. Scaling the columns of the second stage accordingly enables to run both stages under optimal conditions with respect to switching time and step ratio, which is an important advantage as compared to integrated ternary processes. The experimental part starts with studying the linear adsorption behavior of nadolol in heptane/ethanol/DEA on Chiralpak AD for varying ratios of heptane and ethanol. Based on that, a solvent composition of Hept/EtOH/DEA 30/70/0.3 (v/v/v) is selected and the competitive multi-component Langmuir isotherm of the quaternary mixture is determined by frontal analysis. The resulting isotherm parameters are used to design several first stage experiments aiming at removal of the most retained component. The resulting ternary intermediate product is reprocessed in several second stage experiments studying various configurations. Finally, the dilution of the intermediate product with Hept/DEA yielding a solvent composition of Hept/EtOH/DEA 60/40/0.3 (v/v/v) is examined showing that the resulting increase in retention is beneficial for final product purities. Moreover, the reduction in viscosity compensates for the dilution as it enables higher flow rates. Dilution of the intermediate product is hence the best option, yielding highest overall cascade productivity (2.10gl(-1)h(-1)) and highest product purity (97

  13. Determination of antioxidant activity of milk - vegetable extracts byliquid chromatography

    Directory of Open Access Journals (Sweden)

    E. S. Rudnichenko

    2012-01-01

    Full Text Available Antioxidant activity of milk-plant extract of natural sweetener yakon has been established. To extract yakon solid tubers for the first time as an extractant used ultrafiltrate of cheese whey - a product of the extraction separation of whey. Antioxidant activity of extracts was measured amperometrically yakon on the liquid chromatograph "Colour-Yauza-01-AA."A technique for measuring the content of antioxidant. The equations for calculating antioxidant activityyakon. The total content of natural antioxidants can be recommended extract yakon to create new foods with high antioxidant activity.

  14. A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC).

    Science.gov (United States)

    Grosser, Katharina; van Dam, Nicole M

    2017-03-15

    Glucosinolates are a well-studied and highly diverse class of natural plant compounds. They play important roles in plant resistance, rapeseed oil quality, food flavoring, and human health. The biological activity of glucosinolates is released upon tissue damage, when they are mixed with the enzyme myrosinase. This results in the formation of pungent and toxic breakdown products, such as isothiocyanates and nitriles. Currently, more than 130 structurally different glucosinolates have been identified. The chemical structure of the glucosinolate is an important determinant of the product that is formed, which in turn determines its biological activity. The latter may range from detrimental (e.g., progoitrin) to beneficial (e.g., glucoraphanin). Each glucosinolate-containing plant species has its own specific glucosinolate profile. For this reason, it is important to correctly identify and reliably quantify the different glucosinolates present in brassicaceous leaf, seed, and root crops or, for ecological studies, in their wild relatives. Here, we present a well-validated, targeted, and robust method to analyze glucosinolate profiles in a wide range of plant species and plant organs. Intact glucosinolates are extracted from ground plant materials with a methanol-water mixture at high temperatures to disable myrosinase activity. Thereafter, the resulting extract is brought onto an ion-exchange column for purification. After sulfatase treatment, the desulfoglucosinolates are eluted with water and the eluate is freeze-dried. The residue is taken up in an exact volume of water, which is analyzed by high-pressure liquid chromatography (HPLC) with a photodiode array (PDA) or ultraviolet (UV) detector. Detection and quantification are achieved by conducting comparisons of the retention times and UV spectra of commercial reference standards. The concentrations are calculated based on a sinigrin reference curve and well-established response factors. The advantages and

  15. Process monitor design for an extraction column: an application of estimation/detection

    International Nuclear Information System (INIS)

    Candy, J.V.; Emmert, R.A.; Patterson, G.K.

    1979-03-01

    The NRC Safeguards Program at LLL is directed toward developing a methodology for assessing the effectiveness of material control and accounting systems at processing/reprocessing facilities for special nuclear material. The methodology under development requires many types of mathematical models including performance models of safeguard components. Included in the class of safeguard components are real-time measurement systems which incorporate on-line estimators/detectors for the timely detection of material losses. Performance modeling generally involves mathematical model development and simulation of the physical process being measured. This report discusses the development of material estimator designs for a liquid--liquid extraction column using a reprocessing application. These designs are applicable to any processing unit which can be adequately represented by linear or nonlinear models in state space form. Although this work is discussed in the context of a plutonium extraction column, it is representative of two classes of safeguard components which are generic to any fuel cycle involving chemical separations/purifications

  16. Development of a portable, automated system for the separation of radionuclides by column chromatography

    International Nuclear Information System (INIS)

    Schumacher, C.; Burow, M.; Flucht, R.; Hill, P.; Zoriy, M.V.

    2012-01-01

    The determination of the chemical recovery is one of the most important challenges in the radiochemical analysis. Small changes at the pH-value and temperature changes lead to uncontrollable conditions in process. To improve the reproducibility of the chemical determination a separate separating column system (TSM) was developed at the analytic laboratory at JUeLICH. Using the TSM it is possible to separate nuclides by applying variable eluents and ion exchangers also in samples with a very high salt content like urine. Up to now the methods are developed for the elements U, Am and Pu. The automation provides a bigger number of analysed samples per working day and a remarkable economy of time. Due to the increasing of the sample volume it is possible to improve the detection limit of overall analytical procedure (time needed for separation increases). Experimental parameters like rate of flow and chemical recovery were tested. In this progress it was tried to develop a dense portable system which is easy to use. This new TSM allows a realisation of various separating processes by the easy handling via laptop. (orig.)

  17. Determination of Phenolic Acids and Flavonoids in Taraxacum formosanum Kitam by Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Post-Column Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Hung-Ju Chen

    2011-12-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method (LC-MS/MS was developed for the determination of phenolic acids and flavonoids in a medicinal Chinese herb Taraxacum formosanum Kitam. Initially, both phenolic acids and flavonoids were extracted with 50% ethanol in a water-bath at 60 °C for 3 h and eventually separated into acidic fraction and neutral fraction by using a C18 cartridge. A total of 29 compounds were separated within 68 min by employing a Gemini C18 column and a gradient solvent system of 0.1% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Based on the retention behavior as well as absorption and mass spectra, 19 phenolic acids and 10 flavonoids were identified and quantified in T. formosanum, with the former ranging from 14.1 μg/g to 10,870.4 μg/g, and the latter from 9.9 μg/g to 325.8 μg/g. For further identification of flavonoids, a post-column derivatization method involving shift reagents such as sodium acetate or aluminum chloride was used and the absorption spectral characteristics without or with shift reagents were compared. An internal standard syringic acid was used for quantitation of phenolic acids, whereas (± naringenin was found suitable for quantitation of flavonoids. The developed LC-MS/MS method showed high reproducibility, as evident from the relative standard deviation (RSD values for intra-day and inter-day variability being 1.0–6.8% and 2.0–7.7% for phenolic acids and 3.7–7.4% and 1.5–8.1% for flavonoids, respectively, and thus may be applied for simultaneous determination of phenolic acids and flavonoids in Chinese herb and nutraceuticals.

  18. Simultaneous identification and quantification of tetrodotoxin in fresh pufferfish and pufferfish-based products using immunoaffinity columns and liquid chromatography/quadrupole-linear ion trap mass spectrometry

    Science.gov (United States)

    Guo, Mengmeng; Wu, Haiyan; Jiang, Tao; Tan, Zhijun; Zhao, Chunxia; Zheng, Guanchao; Li, Zhaoxin; Zhai, Yuxiu

    2017-07-01

    In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%-107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 μg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information-dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.

  19. [Determination of deoxynivalenol in grain and its products by solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Huang, Juan; Chen, Guosong; Zhang, Xiaoyan; Shen, Chongyu; Lü, Chen; Wu, Bin; Liu, Yan; Chen, Huilan; Ding, Tao

    2012-11-01

    A method was established for the determination of deoxynivalenol (vomitoxin) in grain and its products based on solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The sample was firstly extracted by acetonitrile-water (84:16, v/v). The extract was then cleaned-up by an HLB solid phase extraction cartridge. The separation was carried out on a Phenomenex Kinetex C18 column (100 mm x4. 6 mm, 2.6 microm) with a gradient elution using 0.3% per hundred ammonia solution-acetonitrile as mobile phases. The analysis of deoxynivalenol was performed under electrospray negative ionization mode. The limit of detection (LOD, S/N= 3) and the limit of quantification (LOQ, S/N = 10) were 20 microg/kg and 50 microg/kg, respectively. A good linearity (r > 0.99) was achieved for the target compound over the range of 20-1000 pg/L. The recoveries at the three spiked levels (50, 100, 500 microg/kg) in the blank matrices such as flour, barley, soybean, rice, cornmeal, cassava and wheat, were varied from 75.6% to 111.0% with the relative standard deviations no more than 13. 0%. The method is accurate, efficient, sensitive and practical. The cost of pretreatment is obviously reduced by replacing immunoaffinity columns and Mycosep columns with HLB columns which have the same purification effect.

  20. Simultaneous analysis of nucleobases, nucleosides and ginsenosides in ginseng extracts using supercritical fluid chromatography coupled with single quadrupole mass spectrometry.

    Science.gov (United States)

    Huang, Yang; Zhang, Tingting; Zhao, Yumei; Zhou, Haibo; Tang, Guangyun; Fillet, Marianne; Crommen, Jacques; Jiang, Zhengjin

    2017-09-10

    Nucleobases, nucleosides and ginsenosides, which have a significant impact on the physiological activity of organisms, are reported to be the active components of ginseng, while they are less present in ginseng extracts. Few analytical methods have been developed so far to simultaneously analyze these three classes of compounds with different polarities present in ginseng extracts. In the present study, a simple and efficient analytical method was successfully developed for the simultaneous separation of 17 nucleobases, nucleosides and ginsenosides in ginseng extracts using supercritical fluid chromatography coupled with single quadrupole mass spectrometry (SFC-MS). The effect of various experimental factors on the separation performance, such as the column type, temperature and backpressure, the type of modifier and additive, and the concentration of make-up solvent were systematically investigated. Under the selected conditions, the developed method was successfully applied to the quality evaluation of 14 batches of ginseng extracts from different origins. The results obtained for the different batches indicate that this method could be employed for the quality assessment of ginseng extracts. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A Method for Simultaneous Determination of 20 Fusarium Toxins in Cereals by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry with a Pentafluorophenyl Column

    Science.gov (United States)

    Tamura, Masayoshi; Mochizuki, Naoki; Nagatomi, Yasushi; Harayama, Koichi; Toriba, Akira; Hayakawa, Kazuichi

    2015-01-01

    A high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitrap MS) method was developed for simultaneous determination of 20 Fusarium toxins (nivalenol, fusarenon-X, deoxynivalenol, 3-acetyl deoxynivalenol, 15-acetyl deoxynivalenol, HT-2 toxin, T-2 toxin, neosolaniol, diacetoxyscirpenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisin A1, fumonisin A2, fumonisin A3, zearalenone, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol) in cereals. The separation of 20 Fusarium toxins with good peak shapes was achieved using a pentafluorophenyl column, and Orbitrap MS was able to detect accurately from cereal matrix components within ±0.77 ppm. The samples were prepared using a QuEChERS kit for extraction and a multifunctional cartridge for purification. The linearity, repeatability, and recovery of the method were >0.9964, 0.8%–14.7%, and 71%–106%, respectively. Using this method, an analysis of 34 commercially available cereals detected the presence of deoxynivalenol, 15-acetyl deoxynivalenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisn A1, fumonisin A2, fumonisin A3, and zearalenone in corn samples with high concentration and frequency. Trichothecenes was detected from wheat samples with high frequency; in particular, the concentration of deoxynivalenol was high. Conversely, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol were not detected in any of the samples. PMID:26008230

  2. Gas chromatography-mass spectrometry (GC-MS) analysis of extractives of naturally durable wood

    Science.gov (United States)

    G.T. Kirker; A.B. Blodgett; S.T. Lebow; C.A. Clausen

    2011-01-01

    A preliminary study to evaluate naturally durable wood species in an above ground field trial using Gas Chromatography-Mass Spectrometry (GC-MS) detected differences in fatty acid extractives between species and within the same species over time. Fatty acids were extracted with chloroform: methanol mixture then methylated with sodium methoxide and fractionated using...

  3. Determination of U and Th α-emitters in NORM samples through extraction chromatography by using new and recycled UTEVA resins

    International Nuclear Information System (INIS)

    Casacuberta, N.; Lehritani, M.; Mantero, J.; Masqué, P.; Garcia-Orellana, J.; Garcia-Tenorio, R.

    2012-01-01

    This manuscript describes a protocol for the determination of U and Th isotopes via alpha spectrometry in NORM samples containing high concentrations of these radionuclides, up to kBq kg −1 . This technique is based on extraction chromatography with UTEVA (Triskem Int.) resins and it has been tested using both NORM samples from a phosphate industry and reference materials. The results proved that this method is highly optimized in terms of accuracy and precision when dealing with NORM samples. Recycling of UTEVA columns was also checked using NORM samples and successful results were obtained for both U and Th isotopes, thus proving the feasibility of re-using these type of columns. - Highlights: ► U and Th isotopes in NORM samples are determined via alpha spectrometry. ► The results show a highly optimized data in terms of accuracy and precision. ► Recycling of UTEVA columns was also checked and successful results were obtained.

  4. Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with post-column derivatization.

    Science.gov (United States)

    Miralles, Pablo; Chisvert, Alberto; Alonso, M José; Hernandorena, Sandra; Salvador, Amparo

    2018-03-30

    An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography-ultraviolet/visible (LC-UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sample solution. The extracts were injected into the LC-UV/vis system using phosphate buffer 6 mmol L -1 at pH 2 as mobile phase. After chromatographic separation, the eluate merged with a flow stream of pentane-2,4-dione in ammonium acetate solution as derivatizing reagent and passed throughout a post-column reactor at 85 °C in order to derivatize formaldehyde into 3,5-diacetyl-1,4-dihydrolutidine, according to Hantzsch reaction, which was finally measured spectrophotometrically at 407 nm. The method was successfully validated showing good linearity, an enrichment factor of 86 ± 2, limits of detection and quantification of 0.7 and 2.3 ng mL -1 , respectively, and good repeatability (RSD < 9.2%). Finally, the proposed analytical method was applied to the determination of formaldehyde in different commercial cosmetic samples containing formaldehyde-releasing preservatives, such as bronopol, diazolidinyl urea, imidazolidinyl urea, and DMDM hydantoin, with good relative recovery values (91-113%) thus showing that matrix effects were negligible. The good analytical features of the proposed method besides of its simplicity and affordability, make it useful to carry out the quality control of cosmetic products containing formaldehyde-releasing preservatives. Copyright

  5. Speed-resolution advantage of turbulent supercritical fluid chromatography in open tubular columns: II - Theoretical and experimental evidences.

    Science.gov (United States)

    Gritti, Fabrice; Fogwill, Michael

    2017-06-09

    The potential advantage of turbulent supercritical fluid chromatography (TSFC) in open tubular columns (OTC) was evaluated on both theoretical and practical viewpoints. First, the dispersion model derived by Golay in 1958 and recently extended from laminar to turbulent flow regime is used for the predictions of the speed-resolution performance in TSFC. The average dispersion coefficient of matter in the turbulent flow regime was taken from the available experimental data over a range of Reynolds number from 2000 to 6000. Kinetic plots are built at constant pressure drop (ΔP=4500psi) and Schmidt number (Sc=15) for four inner diameters (10, 30, 100, and 300μm) of the OTC and for three retention factors (0, 1, and 10). Accordingly, in turbulent flow regime, for a Reynolds number of 4000 and a retention factor of 1 (the stationary film thickness is assumed to be negligible with respect to the OTC diameter), the theory projects that a 300μm i.d. OTC has the same speed-resolution power (200,000 theoretical plates; 2.4min hold-up time) as that of a 10μm i.d. OTC operated in laminar flow regime. Secondly, the experimental plate heights of n-butylbenzene are measured in laminar and turbulent flow regimes for a 180μm×4.8m fused silica capillary column using pure carbon dioxide as the mobile phase. The back pressure regulator was set at 1500psi, the temperature was uniform at 297K, and the flow rate was increased step-wise from 0.50 to 3.60mL/min so that the experimental Reynolds number increases from 700 to 5400. The experiments are in good agreement with the plate heights projected in TSFC at high flow rates and with those expected at low flow rates in a laminar flow regime. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Quantitation of triacylglycerols in edible oils by off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column.

    Science.gov (United States)

    Wei, Fang; Hu, Na; Lv, Xin; Dong, Xu-Yan; Chen, Hong

    2015-07-24

    In this investigation, off-line comprehensive two-dimensional liquid chromatography-atmospheric pressure chemical ionization mass spectrometry using a single column has been applied for the identification and quantification of triacylglycerols in edible oils. A novel mixed-mode phenyl-hexyl chromatographic column was employed in this off-line two-dimensional separation system. The phenyl-hexyl column combined the features of traditional C18 and silver-ion columns, which could provide hydrophobic interactions with triacylglycerols under acetonitrile conditions and can offer π-π interactions with triacylglycerols under methanol conditions. When compared with traditional off-line comprehensive two-dimensional liquid chromatography employing two different chromatographic columns (C18 and silver-ion column) and using elution solvents comprised of two phases (reversed-phase/normal-phase) for triacylglycerols separation, the novel off-line comprehensive two-dimensional liquid chromatography using a single column can be achieved by simply altering the mobile phase between acetonitrile and methanol, which exhibited a much higher selectivity for the separation of triacylglycerols with great efficiency and rapid speed. In addition, an approach based on the use of response factor with atmospheric pressure chemical ionization mass spectrometry has been developed for triacylglycerols quantification. Due to the differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of triacylglycerols. This two-dimensional liquid chromatography-mass spectrometry system was successfully applied for the profiling of triacylglycerols in soybean oils, peanut oils and lord oils. A total of 68 triacylglycerols including 40 triacylglycerols in soybean oils, 50 triacylglycerols in peanut oils and 44 triacylglycerols in lord oils have been identified and quantified. The liquid chromatography-mass spectrometry data were analyzed

  7. Evaluation and application of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry for complex sample analysis.

    Science.gov (United States)

    Denawaka, Chamila J; Fowlis, Ian A; Dean, John R

    2014-04-18

    An evaluation of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS) has been undertaken to assess its applicability for the determination of 32 volatile compounds (VCs). The key experimental variables of sample incubation time and temperature have been evaluated alongside the MCC-GC variables of column polarity, syringe temperature, injection temperature, injection volume, column temperature and carrier gas flow rate coupled with the IMS variables of temperature and drift gas flow rate. This evaluation resulted in six sets of experimental variables being required to separate the 32 VCs. The optimum experimental variables for SHS-MCC-GC-IMS, the retention time and drift time operating parameters were determined; to normalise the operating parameters, the relative drift time and normalised reduced ion mobility for each VC were determined. In addition, a full theoretical explanation is provided on the formation of the monomer, dimer and trimer of a VC. The optimum operating condition for each VC calibration data was obtained alongside limit of detection (LOD) and limit of quantitation (LOQ) values. Typical detection limits ranged from 0.1ng bis(methylthio)methane, ethylbutanoate and (E)-2-nonenal to 472ng isovaleric acid with correlation coefficient (R(2)) data ranging from 0.9793 (for the dimer of octanal) through to 0.9990 (for isobutyric acid). Finally, the developed protocols were applied to the analysis of malodour in sock samples. Initial work involved spiking an inert matrix and sock samples with appropriate concentrations of eight VCs. The average recovery from the inert matrix was 101±18% (n=8), while recoveries from the sock samples were lower, that is, 54±30% (n=8) for sock type 1 and 78±24% (n=6) for sock type 2. Finally, SHS-MCC-GC-IMS was applied to sock malodour in a field trial based on 11 volunteers (mixed gender) over a 3-week period. By applying the SHS-MCC-GC-IMS database, four VCs were

  8. Development of a relatively cheap and simple automated separation system for a routine separation procedure based on extraction chromatography

    International Nuclear Information System (INIS)

    Petro Zoriy; Reinhold Flucht; Mechthild Burow; Peter Ostapczuk; Reinhard Lennartz; Myroslav Zoriy

    2010-01-01

    A robust analytical method has been developed in our laboratory for the separation of radionuclides by means of extraction chromatography using an automated separation system. The proposed method is both cheap and simple and provides the advantageous, rapid and accurate separation of the element of interest. The automated separation system enables a shorter separation time by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in the chromatographic column. The present separation method was tested with two types of samples (water and urine) using UTEVA-, TRU- and Sr-specific resins for the separation of U, Th, Am, Pu and Sr. The total separation time for one radionuclide ranged from 60 to 100 min with the separation yield ranging from 68 to 98% depending on the elements separated. We used ICP-QMS, multi-low-level counter and alpha spectroscopy to measure the corresponding elements. (author)

  9. Comparison between a commercial solid-phase extraction cartridge and a home-made silver containing charcoal column: purification of Mo-99 from I-131 and Te-121

    International Nuclear Information System (INIS)

    Dias, Carla Roberta; Teodoro, Rodrigo; Osso Junior, Joao

    2011-01-01

    Among the radioisotopes used for medical application in Nuclear Medicine, 99m Tc, readily available from the elution of 99 Mo/ 99m Tc generators, is the most used, responsible for more than eighty percent of the total applications. These generators use the 99 Mo radioisotope that is produced in nuclear reactors and IPEN imports all the 99 Mo used in Brazil, mainly from Canada (Nordion). Due to the increasing needs of the Nuclear Medicine in Brazil and the world shortage of 99 Mo observed since 2008, IPEN decided to construct a new research reactor named Brazilian Multipurpose Reactor (BMR) as well as to develop the production of 99 Mo through the route of 235 U fission using a CINTICHEM modified separation process. The 99 Mo obtained from this process contains some contaminants and need to be purified. The aim of this work is to compare the preliminary results of the purification step of the solution containing 99 Mo and the contaminants, 131 I and 121 Te in the silver containing charcoal column and a solid-phase extraction cartridge. The purification process of 99 Mo coming from fission LEU foils was performed by adsorption chromatography using a home-made activated charcoal containing silver column (AC-Ag) and a commercial solid-phase extraction cartridge (OnGuard II Ag). High yields of 99 Mo elution and high retention of 131 I were achieved in the AC-Ag column and silver cartridge but 121 Te was more retained in the cartridge than in the AC-Ag column. (author)

  10. Ultrasound-assisted extraction and solid-phase extraction for the simultaneous determination of five amide herbicides in fish samples by gas chromatography with electron capture detection.

    Science.gov (United States)

    Qu, Zhipeng; Bai, Xiuzhi; Zhang, Ting; Yang, Zhaoguang

    2017-03-01

    An efficient sample extraction and clean-up method was developed for simultaneous determination of five amide herbicides (alachlor, acetochlor, propisochlor, metazachlor, and butachlor) in fish samples. The protocol consisted of ultrasound-assisted solvent extraction and solid-phase extraction clean-up. In detail, aliquots of homogenized fish flesh were thoroughly mixed with 20 mL of n-hexane and then extracted with ultrasonication for 40 min. Each sample was centrifuged and the supernatant was collected for the subsequent clean-up. For the sample preparation, the above supernatant was processed with a C 18 column with 3 mL of dichloromethane/n-hexane (1:1, v/v) as the eluant. Then the samples were analyzed by gas chromatography with electron capture detection. The correlation coefficients of the five calibration curves were 0.9976-0.9998 (n = 3). The limits of detection (S/N = 3, n = 11) and limits of quantification (S/N = 10, n = 11) were 0.19-0.42 and 0.63-1.39 μg/kg, respectively. The recoveries of this method were 71.2-92.6% with good precision (<4.7% relative standard deviations, n = 6). The developed method was successfully applied to monitor the five amide herbicides in fish samples collected from different cities. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. [Determination of patulin in fruits and jam by solid phase extraction-ultra performance liquid chromatography].

    Science.gov (United States)

    Lü, Weichao; Shen, Shuchang; Wang, Chao

    2017-11-08

    With magnesium silicate, silica gel, diatomite and calcium sulfate as raw materials, a new solid phase extraction column was prepared through a series of processes of grinding to ethanol homogenate, drying and packing into polypropylene tube. The sample was hydrolyzed by pectinase, extracted by acetonitrile and purified by solid phase extraction. The target compounds were separated on a C18 column (100 mm×2.1 mm, 1.8 μm), using 0.8% (v/v) tetrahydrofuran solution as mobile phase with a flow rate of 0.5 mL/min. The detection wavelength was 276 nm. The effect of pectinase on extraction yield and purification effect of solid-phase extraction column were investigated. The optimum chromatographic conditions were selected. There was a good linear relationship between the peak heights and the mass concentrations of patulin in the range of 0.1 to 10 mg/L with the correlation coefficient ( R 2 ) of 1. The limit of detection for this method was 10.22 μg/kg. The spiked recoveries of samples were 86.58%-94.84% with the relative standard deviations (RSDs) of 1.45%-2.28%. The results indicated that the self-made solid phase extraction column had a good purification efficiency, and the UPLC had a high separation efficiency. The method is simple, accurate and of great significance for the quality and safety control of fruit products.

  12. [Simultaneous determination of glyphosate and glufosinate-ammonium residues in tea by ultra performance liquid chromatography-tandem mass spectrometry coupled with pre-column derivatization].

    Science.gov (United States)

    Wu, Xiaogang; Chen, Xiaoquan; Xiao, Haijun; Liu, Binqiu

    2015-10-01

    A method was developed for the determination of glyphosate (GLY) and glufosinate-ammonium (GLUF) in tea using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample was extracted with ultrapure water and dichloromethane for 30 min under ultrasonication, followed by a simple cleanup with a C18 solid phase extraction (SPE) cartridge, and then GLY and GLUF were derivatized using 9-fluorenylmethoxycarbonyl (FMOC-Cl) in borate buffer for 2 h. The derivatives of GLY and GLUF were separated on a Waters C18 column (50 mm x 2.1 mm, 1.7 μm) in a gradient elution mode, and finally detected with positive electrospray ionization-mass spectrometry (ESI-MS/MS ) in multiple reaction monitoring (MRM) mode. The quantification analysis was performed by external standard method. The method showed a good linearity (r > 0. 990) in the range of 0.003 125-0.1 mg/L. The limits of detection (LODs) of GLY and GLUF were 0.03 mg/kg. At the spiked levels of 0.375, 1.5 and 4.5 mg/kg, the recoveries of GLY and GLUF were 87.37%-99.11% and 81.44% -86.17% respectively, and the relative standard deviations (RSDs) (n = 6) of GLY and GLUF were 0.68%-1.35% and 1.01%-2.33%, respectively. This method is simple, rapid and characterized with acceptable sensitivity and accuracy to meet the requirements for the analysis of GLY and GLUF simultaneously in tea.

  13. Determination of hexavalent chromium concentration in industrial waste incinerator stack gas by using a modified ion chromatography with post-column derivatization method.

    Science.gov (United States)

    Miyake, Yuichi; Tokumura, Masahiro; Iwazaki, Yuta; Wang, Qi; Amagai, Takashi; Horii, Yuichi; Otsuka, Hideyuki; Tanikawa, Noboru; Kobayashi, Takeshi; Oguchi, Masahiro

    2017-06-16

    An ion chromatography with post-column derivatization with 1,5-diphenylcarbazide (IC-DPC) analytical method was modified to enable measurement of trace-level hexavalent chromium (Cr(VI)) in air. One of the difficulties in determining trace levels of Cr(VI) in air with conventional IC-DPC methods is co-elution of the solvent and ion peaks due to high concentrations of ionic compounds in the extract. However, by using gradient elution rather than isocratic elution we were able to fully resolve the Cr(VI) ion peak from the solvent peak without the need for diluting the extract, which would have reduced the minimum quantifiable level of the method. With this method, we were able to detect Cr(VI) in air at concentrations of 5.3ng/m 3 (assuming a sampling volume of 1m 3 and a final solution volume of 10mL). Recovery tests at three different concentrations of Cr(VI) (50, 250, 1000ng) were performed with or without fly ash; recovery rates at all the concentrations of Cr(VI), with or without fly ash, ranged from 68% to 110% (mean±relative standard deviation, 96%±11%), and there were no differences in recovery rates with respect to the presence or absence of fly ash. Finally, we used the developed method to determine the concentration of Cr(VI) in stack gases collected from eight industrial waste incinerators located in Japan. The concentration of Cr(VI) in the stack gases ranged from below the method quantification limit to 3100ng/m 3 . The highest concentrations of Cr(VI) detected in the stack gases were two to three orders of magnitude higher than that in ambient air in Japan. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Design and calculation of tritium extraction from liquid LiPb by bubble columns for ITER

    International Nuclear Information System (INIS)

    Xie, Bo

    2009-04-01

    A mathematical model describing the complex fluid-dynamics of a bubble extractor from liquid LiPb loop for ITER is presented. A parametric analysis of the extraction efficiency of a bubble column as a function of the process parameters is carried out and the design of a bubble extractor system is proposed. On this base, a mathematical model is built by taking into consideration the kinetics of deuterium desorption from liquid LiPb alloy. The calculation data of deuterium release-behavior from liquid LiPb under different operating conditions of temperature and deuterium partial pressures and helium gas flow-rates in the liquid LiPb alloy are obtained. These results have shown that the overall re- lease process is governed by the diffusion of deuterium atoms in the LiPb and by the heterogeneous reaction at the gas-eutectic interface of the deuterium atoms recombination under the probable working temperature range. (authors)

  15. Extraction chromatography of trace concentrations of mercury(II)

    International Nuclear Information System (INIS)

    Smejkal, Z.; Zepla, Z.; Tauferova, J.

    1984-01-01

    The separation of trace amounts of mercury(II) from aqueous solutions has been studied in mixtures of other metal ions (concentration Hg(II) 10 μg/100 ml). The Hg(II) separation was carried out in glass columns filled with Synachrom E-5 carrier impregnanted with a solution of bis(diethyldithiocarbamate)-copper(II) in a mixture of 1.2-dichlorbenzene and cyclohexane (1:1). Trapped Hg(II) was eluted by HCl. The course of the chromatographic process was followed by gamma spectroscopy. Separation yields of Hg(II) were about 90%. (author)

  16. Numerical modelling and experimental validation of hydrodynamics of an emulsion in an extraction column

    International Nuclear Information System (INIS)

    Paisant, Jean-Francois

    2014-01-01

    Industrial reprocessing of spent fuel is based on chemical separation processes by liquid-liquid extraction into pulsed column. The current context of sustainable development and acceptance of nuclear energy drive the industry to improve the efficiency of this process. Pulsed column efficiency is bound to the amount of available exchange surface, which depends on the geometrical parameters of the column and the operating conditions. A better design would improve the efficiency. In this context, the work presented in this manuscript revolves around physical and numerical modelling of the hydrodynamics of the emulsion coupled with the evolution of the interfacial area, as well as an experimental characterization of the quantities which describe the emulsion. The emulsion is modelled based on the work of D. LHUILLIER. It is an Eulerian approach which describes each phase as a continuous medium as well as the interface which is thought as a third phase moving continuously in the flow field. This thesis contributes to describe of the hydrodynamics of dispersed and continuous phases, in order to determine the slip velocity needed for the design. The written transport equation for interfacial area is based on the thesis of T. RANDRIAMANANTENA. The simulation of this physical model was performed using the method of finite elements (FEM) and implementation was carried out under the software CAST3M. The numerical simulation have shown their abilities to correctly reproduce the expected physical behaviour, in particular, they allow to obtain the slip velocity which is essential to the scale up. In a first experimental approach, the single phase flow has been studied in a pulsed column using particle image velocimetry (PIV), for different amplitude and frequency parameters. A method of synchronization between the recording and the pulsation cycle was used in order to achieve this study. The average behavior, for different regimes of pulsation, has been studied by this way. In

  17. Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction.

    Science.gov (United States)

    Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari

    2017-10-01

    Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O -phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C 18 column. The HPLC-DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and

  18. Liquid chromatography coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry and post-column addition of metal salt solutions as a powerful tool for the metabolic profiling of Fusarium oxysporum.

    Science.gov (United States)

    Cirigliano, Adriana M; Rodriguez, M Alejandra; Gagliano, M Laura; Bertinetti, Brenda V; Godeas, Alicia M; Cabrera, Gabriela M

    2016-03-25

    Fusarium oxysporum L11 is a non-pathogenic soil-borne fungal strain that yielded an extract that showed antifungal activity against phytopathogens. In this study, reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry (API-QTOF-MS) was applied for the comprehensive profiling of the metabolites from the extract. The employed sources were electrospray (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). Post-column addition of metal solutions of Ca, Cu and Zn(II) was also tested using ESI. A total of 137 compounds were identified or tentatively identified by matching their accurate mass signals, suggested molecular formulae and MS/MS analysis with previously reported data. Some compounds were isolated and identified by NMR. The extract was rich in cyclic peptides like cyclosporins, diketopiperazines and sansalvamides, most of which were new, and are reported here for the first time. The use of post-column addition of metals resulted in a useful strategy for the discrimination of compound classes since specific adducts were observed for the different compound families. This technique also allowed the screening for compounds with metal binding properties. Thus, the applied methodology is a useful choice for the metabolic profiling of extracts and also for the selection of metabolites with potential biological activities related to interactions with metal ions. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Online turbulent flow extraction coupled with liquid chromatography-tandem mass spectrometry for high throughput screening of anabolic steroids in horse urine.

    Science.gov (United States)

    Shin, Hyun Du; Suh, Joon Hyuk; Kim, Junghyun; Cho, Hyun-Deok; Lee, Su Duk; Han, Kwan Seok; Wang, Yu; Han, Sang Beom

    2017-10-25

    A high throughput method for simultaneous screening of anabolic steroids and their metabolites (4-esterendione, trenbolone, boldenone, oxandrolone, nandrolone, methandrostenolone, testosterone, 1-androstendione, ethisterone, normethandrolone, methyltestosterone, 16β-Hydroxystanozolol, epitestosterone, bolasterone, norethandrolone, danazol, stanozolol and androstadienone) in equine urine by online turbulent flow extraction coupled with liquid chromatography-tandem mass spectrometry was developed. The use of turbulent flow chromatography could simplify pretreatment of horse urine, which has complex matrices as well as high viscosity. The urine was extracted by mixed-mode cation exchange solid phase extraction, and hydrolyzed using β-glucuronidase/arylsulfatase. Then, the sample was automatically loaded on the TurboFlow Cyclone extraction column for removal of further matrix, followed by separation on a fused core C18 column before MS/MS detection. Optimization and validation of the method were discussed in detail. All analytes were rapidly detected within 10min with high sensitivity (picogram to nanogram per milliliter level), and no interference was observed. The linearity range was from 0.1-10ng/mL for nine steroids and 1.0-50ng/mL for the others, with correlation of coefficient values over 0.995. Precision and accuracy ranged from 0.1 to 14.5% and 1.7 to 12.4%, respectively. The developed method was successfully applied to the analysis of anabolic steroids in horse urine after administration of a model drug. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A Microfluidic Device for Preparing Next Generation DNA Sequencing Libraries and for Automating Other Laboratory Protocols That Require One or More Column Chromatography Steps

    Science.gov (United States)

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C.; Quake, Stephen R.; Burkholder, William F.

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation. PMID:23894273

  1. A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps.

    Directory of Open Access Journals (Sweden)

    Swee Jin Tan

    Full Text Available Library preparation for next-generation DNA sequencing (NGS remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.

  2. Sensitive, automatic method for the determination of diazepam and its five metabolites in human oral fluid by online solid-phase extraction and liquid chromatography with tandem mass spectrometry

    DEFF Research Database (Denmark)

    Jiang, Fengli; Rao, Yulan; Wang, Rong

    2016-01-01

    A novel and simple online solid-phase extraction liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of diazepam and its five metabolites including nordazepam, oxazepam, temazepam, oxazepam glucuronide, and temazepam glucuronide...... in human oral fluid. Human oral fluid was obtained using the Salivette(®) collection device, and 100 μL of oral fluid samples were loaded onto HySphere Resin GP cartridge for extraction. Analytes were separated on a Waters Xterra C18 column and quantified by liquid chromatography with tandem mass...

  3. [Simultaneous determination of tryptophan and its metabolites in plasma by high performance liquid chromatography with on-column derivatization].

    Science.gov (United States)

    Feng, Chengya; Gao, Jieying; Zhen, Qianna; Fan, Zimian; Zhu, Mingsong; Yang, Xiangchun; Ding, Min

    2013-06-01

    A high performance liquid chromatography-ultraviolet/fluorescence detection (HPLC-UV/FLD) with on-column derivatization was established to simultaneously determine tryptophan (Trp), kynurenine (Kyn), 5-hydroxyindole acetic acid (5-Hiaa) and kynurenic acid (Kyna). A Hypersil C-18 column (250 mm x 4.0 mm, 5 microm) was used for the analysis at 30 degrees C. The separation was carried out with the mobile phase consisting of 250 mmol/L zinc acetate (pH 5.5) and acetonitrile (95: 5, v/v) at a flow rate of 0.8 mL/min using 3-nitrotyrosine as internal standard (IS). The excitation (Ex) and emission (Em) wavelengths were set at 278 nm (lambda(ex))/343 nm (lambda(em)) for 5-Hiaa and 244 nm (lambda(ex))/400 nm (lambda(em)) for Kyna, while the wavelengths of ultraviolet detection were set at 360 nm for Kyn and IS, 302 nm for Trp. The recoveries were in the range of 91.62% to 114.17%. The linearities were from 2.50 micromol/L to 320.00 micromol/L for Trp, 0.32 micromol/L to 15.36 micromol/L for Kyn, 3.27 nmol/L to 104.60 nmol/L for 5-Hiaa, and 14.00 nmol/L to 464.80 nmol/L for Kyna. The detection limits were 0.078 micromol/L, 0.056 micromol/L, 0.690 nmol/L and 1.290 nmol/L for Trp, Kyn, 5-Hiaa, and Kyna, respectively. Thirty plasma samples of normal pregnant women and 28 plasma samples of healthy controls were tested, and the results exhibited that the concentrations of Trp, Kyn and Kyna in the plasma of the normal pregnant women were significantly different from those of the control group (all P < 0.01). The method is simple and sensitive with good reproducibility, and it is suitable for clinical measurements.

  4. Hydrogen extraction from Pb-17Li: results with a 800 mm high packed column

    International Nuclear Information System (INIS)

    Alpy, N.; Terlain, A.; Lorentz, V.

    2000-01-01

    Within the framework of the studies carried out for the development of a gas-liquid alloy contactor for the extraction of hydrogen from Pb-17Li, the behaviour of a 800 mm high packed column has been investigated on the Melodie loop. The previous contactor technology, a structured packing supplied by the Sulzer Company, has been retained since it had shown satisfying efficiency, likely due to the beneficial effect, on the mass transfer, of the liquid flow division that it involves. The best results of the present study have been achieved via a reduction of the liquid load on the packing: an efficiency of up to 30% was reached at 673 K for an inlet hydrogen pressure in Pb-17Li of 1000 Pa. The impact of the hydrogen pressure in the inlet Pb-17Li flow and on the extraction efficiency has been experimentally assessed: this study allowed us to evaluate the potential of the process in terms of packing height. Finally, a future experimental facility, which should allow us to observe the hydraulic behaviour of liquid mercury (simulating Pb-17Li) on the packing is presented

  5. Preparation and evaluation of 400μm I.D. polymer-based hydrophilic interaction chromatography monolithic columns with high column efficiency.

    Science.gov (United States)

    Liu, Chusheng; Li, Haibin; Wang, Qiqin; Crommen, Jacques; Zhou, Haibo; Jiang, Zhengjin

    2017-08-04

    The quest for higher column efficiency is one of the major research areas in polymer-based monolithic column fabrication. In this research, two novel polymer-based HILIC monolithic columns with 400μm I.D.×800μm O.D. were prepared based on the thermally initiated co-polymerization of N,N-dimethyl-N-(3-methacrylamidopropyl)-N-(3-sulfopropyl) ammonium betaine (SPP) and ethylene glycol dimethacrylate (EDMA) or N,N'-methylenebisacrylamide (MBA). In order to obtain a satisfactory performance in terms of column permeability, mechanical stability, efficiency and selectivity, the polymerization parameters were systematically optimized. Column efficiencies as high as 142, 000 plates/m and 120, 000 plates/m were observed for the analysis of neutral compounds at 0.6mm/s on the poly(SPP-co-MBA) and poly(SPP-co-EDMA) monoliths, respectively. Furthermore, the Van Deemter plots for thiourea on the two monoliths were compared with that on a commercial silica based ZIC-HILIC column (3.5μm, 200Å, 150mm×300μm I.D.) using ACN/H 2 O (90/10, v/v) as the mobile phase at room temperature. It was noticeable that the Van Deemter curves for both monoliths, particularly the poly(SPP-co-MBA) monolith, are significantly flatter than that obtained for the ZIC-HILIC column, which indicates that in spite of their larger internal diameters, they yield better overall efficiency, with less peak dispersion, across a much wider range of usable linear velocities. A clearly better separation performance was also observed for nucleobases, nucleosides, nucleotides and small peptides on the poly(SPP-co-MBA) monolith compared to the ZIC-HILIC column. It is particularly worth mentioning that these 400μm I.D. polymer-based HILIC monolithic columns exhibit enhanced mechanical strength owing to the thicker capillary wall of the fused-silica capillaries. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. MEASUREMENT OF PYRETHROID RESIDUES IN ENVIRONMENTAL AND FOOD SAMPLES BY ENHANCED SOLVENT EXTRACTION/SUPERCRITICAL FLUID EXTRACTION COUPLED WITH GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    The abstract summarizes pyrethorid methods development research. It provides a summary of sample preparation and analytical techniques such as supercritical fluid extraction, enhance solvent extraction, gas chromatography and tandem mass spectrometry.

  7. Physical properties and structure of fine core-shell particles used as packing materials for chromatography Relationships between particle characteristics and column performance.

    Science.gov (United States)

    Gritti, Fabrice; Leonardis, Irene; Abia, Jude; Guiochon, Georges

    2010-06-11

    The recent development of new brands of packing materials made of fine porous-shell particles, e.g., Halo and Kinetex, has brought great improvements in potential column efficiency, demanding considerable progress in the design of chromatographic instruments. Columns packed with Halo and Kinetex particles provide minimum values of their reduced plate heights of nearly 1.5 and 1.2, respectively. These packing materials have physical properties that set them apart from conventional porous particles. The kinetic performance of 4.6mm I.D. columns packed with these two new materials is analyzed based on the results of a series of nine independent and complementary experiments: low-temperature nitrogen adsorption (LTNA), scanning electron microscopy (SEM), inverse size-exclusion chromatography (ISEC), Coulter counter particle size distributions, pycnometry, height equivalent to a theoretical plate (HETP), peak parking method (PP), total pore blocking method (TPB), and local electrochemical detection across the column exit section (LED). The results of this work establish links between the physical properties of these superficially porous particles and the excellent kinetic performance of columns packed with them. It clarifies the fundamental origin of the difference in the chromatographic performances of the Halo and the Kinetex columns. Copyright 2010 Elsevier B.V. All rights reserved.

  8. Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

    Science.gov (United States)

    Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)

    2001-01-01

    A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

  9. Capillary ion chromatography with on-column focusing for ultra-trace analysis of methanesulfonate and inorganic anions in limited volume Antarctic ice core samples.

    Science.gov (United States)

    Rodriguez, Estrella Sanz; Poynter, Sam; Curran, Mark; Haddad, Paul R; Shellie, Robert A; Nesterenko, Pavel N; Paull, Brett

    2015-08-28

    Preservation of ionic species within Antarctic ice yields a unique proxy record of the Earth's climate history. Studies have been focused until now on two proxies: the ionic components of sea salt aerosol and methanesulfonic acid. Measurement of the all of the major ionic species in ice core samples is typically carried out by ion chromatography. Former methods, whilst providing suitable detection limits, have been based upon off-column preconcentration techniques, requiring larger sample volumes, with potential for sample contamination and/or carryover. Here, a new capillary ion chromatography based analytical method has been developed for quantitative analysis of limited volume Antarctic ice core samples. The developed analytical protocol applies capillary ion chromatography (with suppressed conductivity detection) and direct on-column sample injection and focusing, thus eliminating the requirement for off-column sample preconcentration. This limits the total sample volume needed to 300μL per analysis, allowing for triplicate sample analysis with Application to composite ice-core samples is demonstrated, with coupling of the capillary ion chromatograph to high resolution mass spectrometry used to confirm the presence and purity of the observed methanesulfonate peak. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Analysis of trace levels of impurities and hydrogen isotopes in helium purge gas using gas chromatography for tritium extraction system of an Indian lead lithium ceramic breeder test blanket module.

    Science.gov (United States)

    Devi, V Gayathri; Sircar, Amit; Yadav, Deepak; Parmar, Jayraj

    2018-01-12

    In the fusion fuel cycle, the accurate analysis and understanding of the chemical composition of any gas mixture is of great importance for the efficient design of a tritium extraction and purification system or any tritium handling system. Methods like laser Raman spectroscopy and gas chromatography with thermal conductivity detector have been considered for hydrogen isotopes analyses in fuel cycles. Gas chromatography with a cryogenic separation column has been used for the analysis of hydrogen isotopes gas mixtures in general due to its high reliability and ease of operation. Hydrogen isotopes gas mixture analysis with cryogenic columns has been reported earlier using different column materials for percentage level composition. In the present work, trace levels of hydrogen isotopes (∼100 ppm of H 2 and D 2 ) have been analyzed with a Zeolite 5A and a modified γ-Al 2 O 3 column. Impurities in He gas (∼10 ppm of H 2 , O 2 , and N 2 ) have been analyzed using a Zeolite 13-X column. Gas chromatography with discharge ionization detection has been utilized for this purpose. The results of these experiments suggest that the columns developed were able to separate ppm levels of the desired components with a small response time (<6 min) and good resolution in both cases. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Chemical characterization using gas chromatography/mass spectrometry of two extracts from Phyllanthus orbicularis HBK

    International Nuclear Information System (INIS)

    Gutierrez Gaiten, Yamilet Irene; Miranda Martinez, Migdalia; Bello Alarcon, Adonis

    2011-01-01

    The objective of this paper was the chemical characterization of two extracts from Phyllanthus orbicularis HBK through gas chromatography/mass spectrometry. To this end, maceration with N-hexane and ethyl acetate was used to obtain the respective extracts. The study of the hexane extract identified 17 components in which hydrocarbonate structures prevailed, mainly cyclooctacosane. In the ethyl acetate extract, 19 compounds were detected, being the terpenoids the predominant, although the most abundant was sterol g-sitosterol. For the first time, the identified compounds are reported for this species

  12. Hydroxylapatite chromatography.

    Science.gov (United States)

    Broadhurst, A V

    2001-05-01

    Hydroxylapatite (also called hydroxyapatite), a form of calcium phosphate, can be used as a matrix for the chromatography of both proteins and nucleic acids. Protocols are provided for both standard low-pressure chromatography of a protein mixture using a hydroxylapatite column prepared in the laboratory, and an HPLC method, applicable to proteins and nucleic acids, that uses a commercially available column. Alternate protocols describe column chromatography using a step gradient or batch binding and step-gradient elution.

  13. On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample.

    Science.gov (United States)

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-11-10

    An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.

  14. Applications of extraction chromatography in the development of radionuclide generator systems for nuclear medicine

    International Nuclear Information System (INIS)

    Dietz, M.L.; Horwitz, E.P.

    2000-01-01

    Numerous methods have been described for the separation and purification of radionuclides for application in diagnostic and therapeutic nuclear medicine, among them ion exchange, solvent extraction, and various forms of chromatography. Although extraction chromatography has previously been shown to provide a means of performing a number of separations of potential use in radionuclide generator systems, the application of the technique to generator development has thus far been limited. Recent work directed at improved methods for the determination of radionuclides in biological and environmental samples has led to the development of a series of novel extraction chromatographic resins exhibiting enhanced metal ion retention from strongly acidic media and excellent selectivity, among them materials suitable for the isolation of 212 Bi, 90 Y, and 213 Bi. These resins, along with extraction chromatographic materials employing functionalized supports to improve their physical stability or metal ion retention properties, are shown to offer promise in the development of improved radionuclide generators

  15. Semi-permeable surface analytical reversed-phase column for the improved trace analysis of acidic pesticides in water with coupled-column reversed-phase liquid chromatography with UV detection. Determination of bromoxynil and bentazone in surface water.

    Science.gov (United States)

    Hogendoorn, E A; Westhuis, K; Dijkman, E; Heusinkveld, H A; den Boer, A C; Evers, E A; Baumann, R A

    1999-10-08

    The coupled-column (LC-LC) configuration consisting of a 3 microm C18 column (50 x 4.6 mm I.D.) as the first column and a 5 microm C18 semi-permeable-surface (SPS) column (150 x 4.6 mm I.D.) as the second column appeared to be successful for the screening of acidic pesticides in surface water samples. In comparison to LC-LC employing two C18 columns, the combination of C18/SPS-C18 significantly decreased the baseline deviation caused by the hump of the co-extracted humic substances when using UV detection (217 nm). The developed LC-LC procedure allowed the simultaneous determination of the target analytes bentazone and bromoxynil in uncleaned extracts of surface water samples to a level of 0.05 microg/l in less than 15 min. In combination with a simple solid-phase extraction step (200 ml of water on a 500 mg C18-bonded silica) the analytical procedure provides a high sample throughput. During a period of about five months more than 200 ditch-water samples originating from agricultural locations were analyzed with the developed procedure. Validation of the method was performed by randomly analyzing recoveries of water samples spiked at levels of 0.1 microg/l (n=10), 0.5 microg/l (n=7) and 2.5 microg/l (n=4). Weighted regression of the recovery data showed that the method provides overall recoveries of 95 and 100% for bentazone and bromoxynil, respectively, with corresponding intra-laboratory reproducibilities of 10 and 11%, respectively. Confirmation of the analytes in part of the samples extracts was carried out with GC-negative ion chemical ionization MS involving a derivatization step with bis(trifluoromethyl)benzyl bromide. No false negatives or positives were observed.

  16. Determination of lansoprazole enantiomers in dog plasma by column-switching liquid chromatography with tandem mass spectrometry and its application to a preclinical pharmacokinetic study.

    Science.gov (United States)

    Wang, Hao; Sun, Yantong; Meng, Xiangjun; Yang, Bo; Wang, Jian; Yang, Yan; Gu, Jingkai

    2015-09-01

    Lansoprazole, a selective proton pump inhibitor, has a chiral benzimidazole sulfoxide structure and is used for the treatment of gastric acid hypersecretory related diseases. To investigate its stereoselective pharmacokinetics, a column-switching liquid chromatography with tandem mass spectrometry method was developed for the determination of lansoprazole enantiomers in dog plasma using (+)-pantoprazole as an internal standard. After a simple protein precipitation procedure with acetonitrile, matrix components left behind after sample preparation were further eliminated from the sample by reversed-phase chromatography on a C18 column. The fluent was fed to a chiral column for the separation of lansoprazole enantiomers. Baseline separation of lansoprazole enantiomers was achieved on a Chiralcel OZ-RH column using acetonitrile/0.1% formic acid in water (35:65, v/v) as the mobile phase at 40°C. The linearity of the calibration curves ranged from 3 to 800 ng/mL for each enantiomer. Intra- and inter-day precisions ranged from 2.1 to 7.3% with an accuracy of ±1.7% for (+)-lansoprazole, and from 1.6 to 6.9% with an accuracy of ±3.5% for (-)-lansoprazole, respectively. The validated method was successfully applied for the stereoselective pharmacokinetic study of lansoprazole in beagle dog after intravenous infusion. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Determination of Pb-210 and actinides by extraction chromatography and anion exchange chromatography

    International Nuclear Information System (INIS)

    Kalmykov, St.N.; Sapozhnikov, Yu.A.

    1997-01-01

    This work is devoted to the determination of Pb-210 and actinides (Pu-238, Pu-239, Am-241, U-235, U-238, Th-232) by means of highly selective chromatographic resins and anion exchangers. The special interest was paid to the analysis of large quantities of samples with high concentration of competitive ions like ocean sediments, bone ash and others.The commercially available TRU-Spec chromatographic resins was used for separation of actinides from the matrix. Then U, Th, Am, and Pu were separated from other using anion exchange chromatography with AG-1X4 anionite in Cl - form, electro-deposed and α-counted.Pb-21- and Bi-210 were determined by liquid scintillation counting. The developed procedure is rather express, effective and could be adopted for the determination of radionuclides like Ba-133, Ra, Np-239

  18. Simultaneous determination of secondary metabolites from Vinca rosea plant extractives by reverse phase high performance liquid chromatography

    Science.gov (United States)

    Siddiqui, Mohammad Jamshed Ahmad; Ismail, Zhari; Saidan, Noor Hafizoh

    2011-01-01

    Background: Vinca rosea (Apocynaceae) is one of the most important and high value medicinal plants known for its anticancer alkaloids. It is the iota of the isolated secondary metabolites used in chemotherapy to treat diverse cancers. Several high performance liquid chromatography (HPLC) methods have been developed to quantify the active alkaloids in the plant. However, this method may serve the purpose in quantification of V. rosea plant extracts in totality. Objective: To develop and validate the reverse phase (RP)-HPLC method for simultaneous determination of secondary metabolites, namely alkaloids from V. rosea plant extracts. Materials and Methods: The quantitative determination was conducted by RP-HPLC equipped with ultraviolet detector. Optimal separation was achieved by isocratic elution with mobile phase consisting of methanol:acetonitrile:ammonium acetate buffer (25 mM) with 0.1% triethylamine (15:45:40 v/v) on a column (Zorbax Eclipse plus C18, 250 mm % 4.6 mm; 5 μm). The standard markers (vindoline, vincristine, catharanthine, and vinblastine) were identified by retention time and co-injected with reference standard and quantified by external standard method at 297 nm. Results: The precision of the method was confirmed by the relative standard deviation (R.S.D.), which was lower than 2.68%. The recoveries were in the range of 98.09%-108%. The limits of detection (LOD) for each marker alkaloids were lower than 0.20 μg. Different parts of the V. rosea extracts shows different concentrations of markers, flower samples were high in vinblastine content, while methanol extract from the leaves contains all the four alkaloids in good yield, and there is no significant presence of markers in water extracts. Conclusion: HPLC method established is appropriate for the standardization and quality assurance of V. rosea plant extracts. PMID:21716929

  19. A fast and accurate method for the pharmacokinetic research of four coumarin analogs in Fructus cnidii using capillary electro-chromatography with a methacrylate ester-based monolithic column.

    Science.gov (United States)

    Chen, Zhao; Xu, Aili; Bi, Xiaoli; Luo, Wenhui; Li, Ji; Fan, Guorong; Sun, Dongmei

    2017-11-01

    In the present study, a monolithic capillary column with higher permeability was developed for the in vivo discrimination of four coumarin analogs (bergapten, 2'-acetylangelicin, imperatorin, and osthole) that typically require long separation times in HPLC. Instead of conventional methacrylate ester monolith (containing 19.5% porogen) with insufficient permeability (K = 1.52 - 1.66 × 10 -14 M 2 ) for plasma sample, the proposed column (20.5% porogen) had better permeability (around 3.80 × 10 -14 M 2 ) while properties such as pore distribution, stability, and resolution changed slightly. As a result, due to the negatively charged electro-dynamic flow of the methacrylate ester groups in the monolith, the migration of targeted analytes was achieved within 6 min (compared with 30 min in HPLC) with acceptable resolution and improved sensitivity (0.005-0.02 μg/mL vs. 0.04 μg/mL). The proposed method was also applied to pharmacokinetic research: accelerated solvent extraction (ASE) was used to improve the extraction efficiency, which prepared extract much faster and more pure than conventional methods. As the pharmacokinetic parameters indicated, the monolithic capillary electro-chromatography method was efficient, sensitive, specific, and durable, guaranteeing its utility for the determination of multiple structure-related compounds in rat plasma. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Quantitative Analysis of Bioactive Compounds from Aromatic Plants by Means of Dynamic Headspace Extraction and Multiple Headspace Extraction-Gas Chromatography-Mass Spectrometry

    NARCIS (Netherlands)

    Omar, Jone; Olivares, Maitane; Alonso, Ibone; Vallejo, Asier; Aizpurua-Olaizola, Oier; Etxebarria, Nestor

    2016-01-01

    Seven monoterpenes in 4 aromatic plants (sage, cardamom, lavender, and rosemary) were quantified in liquid extracts and directly in solid samples by means of dynamic headspace-gas chromatography-mass spectrometry (DHS-GC-MS) and multiple headspace extraction-gas chromatography-mass spectrometry

  1. Relating pressure tuned coupled column ensembles with the solvation parameter model for tunable selectivity in gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Chin, Sung-Tong; Marriott, Philip J

    2016-07-15

    The differential pressure drop of carrier gas by tuning the junction point pressure of a coupled column gas chromatographic system leads to a unique selectivity of the overall separation, which can be tested using a mixture of compounds with a wide range of polarity. This study demonstrates a pressure tuning (PT) GC system employing a microfluidic Deans switch located at the mid-point of the two capillary columns. This PT system allowed variations of inlet-outlet pressure differences of the two columns in a range of 52-17psi for the upstream column and 31-11psi for the downstream column. Peak shifting (differential migration) of compounds due to PT difference are related to a first order regression equation in a Plackett-Burman factorial study. Increased first (upstream) column pressure drop makes the second column characteristics more significant in the coupled column retention behavior, and conversely increased second (downstream) column pressure drop makes the first column characteristics more apparent; such variation can result in component swapping between polar and non-polar compounds. The coupled column system selectivity was evaluated in terms of linear solvation energy relationship (LSER) parameters, and their relation with different pressure drop effects has been constructed by applying multivariate principle component analysis (PCA). It has been found that the coupled column PT system descriptors provide a result that shows a clear clustering of different pressure settings, somewhat intermediate between those of the two commercial columns. This is equivalent to that obtained from a conventional single-column GC analysis where the interaction energy contributed from the stationary phases can be significantly adjusted by choice of midpoint PT. This result provides a foundation for pressure differentiation for selectivity enhancement. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Comparison of the performance of full scale pulsed columns vs. mixer-settlers for uranium solvent extraction

    International Nuclear Information System (INIS)

    Movsowitz, R.L.; Kleinberger, R.; Buchalter, E.M.; Grinbaum, B.

    2000-01-01

    A rare opportunity arose to compare the performance of Bateman Pulsed Columns (BPC) vs. Mixer-Settlers at an industrial site, over a long period, when the Uranium Solvent Extraction Plant of WMC at Olympic Dam, South Australia was upgraded. The original plant was operated for years with two trains of 2-stage mixer-settler batteries for the extraction of uranium. When the company decided to increase the yield of the plant, the existing two trains of mixer-settlers for uranium extraction were arranged in series, giving one 4-stage battery. In parallel, two Bateman Pulsed Columns, of the disc-and-doughnut type, were installed to compare the performance of both types of equipment over an extended period.The plant has been operating in parallel for three years and the results show that the performance of the columns is excellent: the extraction yield is similar to the 4 mixer-settlers in series - about 98%, the entrainment of solvent is lower, there are less mechanical failures, less problems with crud, smaller solvent losses and the operation is simpler. The results convinced WMC to install an additional 10 BPC's for the expansion of their uranium plant. These columns were successfully commissioned early 1999. This paper includes quantitative comparison of both types of equipment. (author)

  3. Enantioselective determination of 3-n-butylphthalide (NBP) in human plasma by liquid chromatography on a teicoplanin-based chiral column coupled with tandem mass spectrometry.

    Science.gov (United States)

    Diao, Xingxing; Ma, Zhiyu; Lei, Peng; Zhong, Dafang; Zhang, Yifan; Chen, Xiaoyan

    2013-11-15

    A novel and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to determine the exposure of 3-n-butylphthalide (NBP) enantiomers in human plasma. The NBP enantiomers were extracted from human plasma using methyl tert-butyl ether. The baseline separation of R-(+)-NBP and S-(-)-NBP was achieved within 11.0min using a teicoplanin-based Astec Chirobiotic T column (250mm×4.6mm i.d., 5μm) under isocratic conditions at a flow rate of 0.6mL/min. The selection of the chiral stationary phase and the effect of the mobile phase composition on the resolution of the enantiomers were discussed. The selectivity, linearity, precision, accuracy, matrix effect, recovery, and stability were evaluated under optimized conditions. The LC-MS/MS method using 200μL of human plasma was linear over the concentration range of 5.00-400ng/mL for each enantiomer. The lower limit of quantification (LLOQ) for both enantiomers was 5.00ng/mL. The intra- and inter-assay precision values of the replicated quality control samples were within 8.0% for each enantiomer. The mean accuracy values for the quality control samples were within ±6.1% of the nominal values for R-(+)-NBP and S-(-)-NBP. No chiral inversion was observed during sample storage, preparation, and analysis. The method proved suitable for enantioselective pharmacokinetic studies of NBP after an oral administration of a therapeutic dose of racemic NBP. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Separation of some rare earths with the aid of extraction chromatography Pt. 1

    International Nuclear Information System (INIS)

    Baranyai, R.

    1982-01-01

    Some model systems built up by some rare earths have been separated by extraction chromatography. As shown experimentally, by changing the concentration of the acids used as eluents, tri-n-butyl-phosphate can successfully be applied as the stationary phase fixed on a proper support. The separation process is rapid and efficient. (author)

  5. Investigation of parameters affecting the online combination of supercritical fluid extraction with capillary gas chromatography

    NARCIS (Netherlands)

    Lou, X.W.; Janssen, J.G.M.; Cramers, C.A.M.G.

    1996-01-01

    Two different injectors, a split/splitless injector and a programmed temperature vaporizer (PTV) injector were investigated as the interface in on-line supercritical fluid extraction (SFE)-capillary gas chromatography (cGC). The parameters affecting the chromatographic peak shapes as well as the

  6. SEMIAUTOMATED SOLID-PHASE EXTRACTION PROCEDURE FOR DRUG SCREENING IN BIOLOGICAL-FLUIDS USING THE ASPEC SYSTEM IN COMBINATION WITH CLEAN SCREEN DAU COLUMNS

    NARCIS (Netherlands)

    CHEN, XH; FRANKE, JP; ENSING, K; WIJSBEEK, J; DEZEEUW, RA

    1993-01-01

    The use of a semi-automated solid-phase extraction system (ASPEC) for the screening of drugs in plasma and urine on a single mixed-mode column (Clean Screen DAU) is described. The processes of column preconditioning, sample application, column wash, pH adjustment and elution of the drugs were

  7. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Akihiro [Scientific Investigation Laboratory, Hiroshima Prefectural Police Headquarters, Kohnan 2-26-3, Naka-ku, Hiroshima 730-0825 (Japan); Nishida, Manami [Hiroshima University Technical Center, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan); Saito, Takeshi [Department of Emergency and Critical Care Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara, Kanagawa 259-1143 (Japan); Kishiyama, Izumi; Miyazaki, Shota [GL Sciences Inc., Sayamagahara 237-2, Iruma, Saitama 358-0032 (Japan); Murakami, Katsunori [Scientific Investigation Laboratory, Hiroshima Prefectural Police Headquarters, Kohnan 2-26-3, Naka-ku, Hiroshima 730-0825 (Japan); Nagao, Masataka [Department of Forensic Medicine, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan); Namura, Akira, E-mail: namera@hiroshima-u.ac.jp [Department of Forensic Medicine, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551 (Japan)

    2010-02-19

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d{sub 5} was used as an internal standard. The linear ranges were 0.01-5.0 {mu}g mL{sup -1} for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 {mu}g mL{sup -1} for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation {>=}0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 {mu}g mL{sup -1} of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio {>=} 3) in urine was 5 ng mL{sup -1} for MA and MDMA and 10 ng mL{sup -1} for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.

  8. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection.

    Science.gov (United States)

    Nakamoto, Akihiro; Nishida, Manami; Saito, Takeshi; Kishiyama, Izumi; Miyazaki, Shota; Murakami, Katsunori; Nagao, Masataka; Namura, Akira

    2010-02-19

    A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d(5) was used as an internal standard. The linear ranges were 0.01-5.0 microg mL(-1) for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 microg mL(-1) for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation > or = 0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 microg mL(-1) of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio > or = 3) in urine was 5 ng mL(-1) for MA and MDMA and 10 ng mL(-1) for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation. Copyright 2009 Elsevier B.V. All rights reserved.

  9. Use of on-line supercritical fluid extraction-supercritical fluid chromatography/tandem mass spectrometry to analyze disease biomarkers in dried serum spots compared with serum analysis using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Suzuki, Makoto; Nishiumi, Shin; Kobayashi, Takashi; Sakai, Arata; Iwata, Yosuke; Uchikata, Takato; Izumi, Yoshihiro; Azuma, Takeshi; Bamba, Takeshi; Yoshida, Masaru

    2017-05-30

    The analytical stability and throughput of biomarker assays based on dried serum spots (DSS) are strongly dependent on the extraction process and determination method. In the present study, an on-line system based on supercritical fluid extraction-supercritical fluid chromatography coupled with tandem mass spectrometry (SFE-SFC/MS/MS) was established for analyzing the levels of disease biomarkers in DSS. The chromatographic conditions were investigated using the ODS-EP, diol, and SIL-100A columns. Then, we optimized the SFE-SFC/MS/MS method using the diol column, focusing on candidate biomarkers of oral, colorectal, and pancreatic cancer that were identified using liquid chromatography (LC)/MS/MS. By using this system, four hydrophilic metabolites and 17 hydrophobic metabolites were simultaneously detected within 15 min. In an experiment involving clinical samples, PC 16:0-18:2/16:1-18:1 exhibited 93.8% sensitivity and 64.3% specificity, whereas PC 17:1-18:1/17:0-18:2 showed 81.3% sensitivity and 92.9% specificity for detecting oral cancer. In addition, assessments of the creatine levels demonstrated 92.3% sensitivity and 78.6% specificity for detecting colorectal cancer. The results of this study indicate that our method has great potential for clinical diagnosis and would be suitable for large-scale screening. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Radioimmunoassay of thyroxine and triiodothyronine in urine using extraction and separation on Sephadex columns

    International Nuclear Information System (INIS)

    Rogowski, P.; Siersbaek-Nielsen, K.

    1977-01-01

    Radioimmunological methods for the determination of thyroxine (T4) and triiodothyronine (T3) in urine have been developed. The methods are based on trapping of T4 and T3 from unextracted urine, followed by separation between free and antibody bound hormone on the same Sephadex column. The T4 method has been compared to a competitive protein binding (CPB) assay using ethyl acetate extraction. The methods are evaluated in sixty-seven euthyroid controls, twenty-four hyperthyroid and seven hypothyroid patients. In the T4 RIA detection limit was 3.9 pg, intra-assay coefficient of variation (cv) was 5.2% and inter-assay cv was 6.9%. In the T3 RIA detection limit was 7.2 pg, intra-assay cv 3.9% and inter-assay cv 10.8%. Recovery of added amounts of hormones and serial dilutions gave satisfactory results. The CPB assay was found unreliable with unspecific and false high values. In euthyroid controls 24 h urinary T4 excretion as measured by RIA was 1.8+-0.5 nmol, and urinary T3 excretion was 0.7+-0.3 nmol. T4 and T3 excretion was greatly elevated in hyperthyroid patients and decreased in hypothyroidism. (Auth.)

  11. Description of design and operating procedures of small scale pulsed columns for experimental study on extraction process under abnormal conditions

    International Nuclear Information System (INIS)

    Wakamatsu, Sachio; Sato, Makoto; Kubo, Nobuo; Sakurai, Satoshi; Ami, Norio

    1990-09-01

    To study transient phenomena in a pulsed column co-decontamination process under abnormal conditions, a pair of small scale pulsed columns (effective extraction section; I.D: 25 mm, H.: 2260 mm) for extraction and scrub were installed in the laboratory. An evaporator of aqueous uranium solution was also equipped to reuse concentrated solution as the feed. This report describes several items to have been carefully treated in design, specification and operating procedure of the apparatuses for the experiments. Also described are the procedures for preparation of the feed solutions and treatments of the solutions after the experiments; back-extraction of uranium, diluent washing, alkaline washing and concentration of uranium solution. (author)

  12. Investigating sub-2 μm particle stationary phase supercritical fluid chromatography coupled to mass spectrometry for chemical profiling of chamomile extracts.

    Science.gov (United States)

    Jones, Michael D; Avula, Bharathi; Wang, Yan-Hong; Lu, Lu; Zhao, Jianping; Avonto, Cristina; Isaac, Giorgis; Meeker, Larry; Yu, Kate; Legido-Quigley, Cristina; Smith, Norman; Khan, Ikhlas A

    2014-10-17

    Roman and German chamomile are widely used throughout the world. Chamomiles contain a wide variety of active constituents including sesquiterpene lactones. Various extraction techniques were performed on these two types of chamomile. A packed-column supercritical fluid chromatography-mass spectrometry method was designed for the identification of sesquiterpenes and other constituents from chamomile extracts with no derivatization step prior to analysis. Mass spectrometry detection was achieved by using electrospray ionization. All of the compounds of interest were separated within 15 min. The chamomile extracts were analyzed and compared for similarities and distinct differences. Multivariate statistical analysis including principal component analysis and orthogonal partial least squares-discriminant analysis (OPLS-DA) were used to differentiate between the chamomile samples. German chamomile samples confirmed the presence of cis- and trans-tonghaosu, chrysosplenols, apigenin diglucoside whereas Roman chamomile samples confirmed the presence of apigenin, nobilin, 1,10-epioxynobilin, and hydroxyisonobilin. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Highly Sensitive Determination of 2,4,6-Trinitrotoluene and Related Byproducts Using a Diol Functionalized Column for High Performance Liquid Chromatography

    Science.gov (United States)

    Gumuscu, Burcu; Erdogan, Zeynep; Guler, Mustafa O.; Tekinay, Turgay

    2014-01-01

    In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95–98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation. PMID:24905826

  14. Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.

    Science.gov (United States)

    Gumuscu, Burcu; Erdogan, Zeynep; Guler, Mustafa O; Tekinay, Turgay

    2014-01-01

    In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95-98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation.

  15. Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.

    Directory of Open Access Journals (Sweden)

    Burcu Gumuscu

    Full Text Available In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT; 2,4-dinitrotoluene (2,4-DNT; 2,6-dinitrotoluene (2,6-DNT; 2-aminodinitrotoluene (2-ADNT and 4-aminodinitrotoluene (4-ADNT molecules in high-performance liquid-chromatography (HPLC with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95-98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation.

  16. Simultaneous determination of actinide and strontium nuclides by extraction chromatography

    International Nuclear Information System (INIS)

    Vajda, N.; Molnar, Zs.

    1999-01-01

    A relatively fast and simple separation procedure has been developed for the simultaneous determination of thorium, uranium, neptunium, plutonium, americium, curium and strontium radionuclides. Most of the isotopes of these elements are long-lived, pure alpha and beta emitters regarded as 'difficult to determine' ones in the literature. Our major goal was to develop a combined procedure capable for the analysis of all these nuclides in the same sample aliquot so that correlations can be revealed without the errors arising due to inhomogeneity of samples when the radionuclides are determined from different sub-samples. The combined procedure has the advantage that sample destruction becomes simpler and faster, too. The chemical procedure consists of co-precipitations for the pre-concentration of groups of chemically similar elements and extraction chromatographic separations for the purification of individual elements. By means of pre-concentration relatively big samples can be treated offering the possibility of low activity measurements that cannot be performed by analysing small sample amounts. Pre-concentration techniques were always chosen in order to improve the selectivity of the following separation steps. (authors)

  17. Method development for determination of herbicides and insecticides in surface waters using solid-phase extraction and high performance liquid chromatography

    International Nuclear Information System (INIS)

    Lebre, Daniel Temponi

    2000-01-01

    Determination of low concentrations of pesticides in surface and ground waters requires high sensitivity analytical techniques. Solid-Phase Extraction (SPE) has been successfully employed to pre concentrate and extract pesticides compounds from water samples. High Performance Liquid Chromatography (HPLC) coupled with UV/Vis detector was used to separate and quantify the extracted compounds. In this work, samples of surface waters with known concentrations of herbicides (atrazine, simazine and trifluralin) and insecticides (aldicarb, carbofuran and carbaryl) were extracted by using SPE off-line technique. The compounds were separated and quantified by reverse phase HPLC with UV detection at 220 ηm. The extraction efficiency was compared between two columns filled with different materials: C 18 -bonded silica phase (500 mg) and copolymer styrenedivynilbenzene resin (250 mg). The results were evaluated as the percent recovery of compounds obtained using different solvents at different concentrations. The results showed that recovery of the analytes greater than 80 % were obtained in SPE columns filled with C 18 bonded silica phase with 6 mL of acetonitrile. Once the optimum conditions were chosen for simulate water samples, the method was validated through analytical and statistical procedures and applied for surface waters. The suitability of the method was verified for the studied compounds showing good sensitivity, i. e., concentrations within the range of 0.4 to 4.0 μgL -1 of pesticides could be quantified attending the limits proposed by official regulations. (author)

  18. The determination of pentobarbital and other barbiturates in blood plasma by gas—liquid chromatography with on-column and pre-column butylation

    NARCIS (Netherlands)

    Hulshoff, A.; Houwen, O.A.G.J. van der; Barends, D.M.; Kostenbauder, H.B.

    1979-01-01

    Two g.l.c. methods for the determination of pentobarbital and other barbiturates are reported. In the first method the plasma samples are extracted with toluene; the toluene layer is back-extracted with a small volume of a tetrabutylammonium hydroxide solution of which an aliquot is injected into

  19. [Determination of short chain chlorinated paraffins in leather products by solid phase extraction coupled with gas chromatography-mass spectrometry].

    Science.gov (United States)

    Zhang, Weiya; Wan, Xin; Li, Lixia; Wang, Chengyun; Jin, Shupei; Xing, Jun

    2014-10-01

    The short chain chlorinated paraffins (SCCPs) are the additives frequently used in the leather production in China, but they have been put into the list of forbidden chemicals issued by European Union recently. In fact, there is not a commonly recognized method for the determination of the SCCPs in the leather products due to the serious matrix interferences from the leather products and the complex chemical structures of the SCCPs. A method of solid phase extraction coupled with gas chromatography-mass spectrometry (SPE-GC-MS) was established for the determination of the SCCPs in the leather products after the optimization of the SPE conditions. It was found that the interferences from the leather products were thor- oughly separated from the analyte of the SCCPs on a home-made solid phase extraction (SPE) column filled with silica packing while eluted with a mixed solvent of n-hexane-methylene chloride (2:1, v/v). With this method, the recoveries for the SCCPs spiked in the real leather samples varied from 90.47% to 99.00% with the relative standard deviations (RSDs) less than 6.7%, and the limits of detection (LODs) were between 0.069 and 0.110 mg/kg. This method is suitable for qualitative and quantitative analysis of SCCPs in the leather products.

  20. Determination of phthalates released from paper packaging materials by solid-phase extraction-high-performance liquid chromatography.

    Science.gov (United States)

    Gao, Xin; Yang, Bofeng; Tang, Zhixu; Luo, Xin; Wang, Fengmei; Xu, Hui; Cai, Xue

    2014-01-01

    A solid phase extraction (SPE) high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of 10 phthalic acid esters (dimethyl phthalate, diethyl phthalate, dipropyl phthalate, benzylbutyl phthalate, diisobutyl phthalate, dicyclohexyl phthalate, diamyl phthalate, di-n-hexyl phthalate, di-n-octyl phthalate and di-2-ethylhexyl phthalate) released from food paper packaging materials. The use of distilled water, 3% acetic acid (w/v), 10% ethanol (v/v) and 95% ethanol (v/v) instead of the different types of food simulated the migration of 10 phthalic acid esters from food paper packaging materials; the phthalic acid esters in four food simulants were enriched and purified by a C18 SPE column and nitrogen blowing, and quantified by HPLC with a diode array detector. The chromatographic conditions and extraction conditions were optimized and all 10 of the phthalate acid esters had a maximum absorbance at 224 nm. The method showed limitations of detection in the range of 6.0-23.8 ng/mL the correlation coefficients were greater than 0.9999 in all cases, recovery values ranged between 71.27 and 106.97% at spiking levels of 30, 60 and 90 ng/mL and relative standard deviation values ranged from 0.86 to 8.00%. The method was considered to be simple, fast and reliable for a study on the migration of these 10 phthalic acid esters from food paper packaging materials into food.

  1. Rapid method for determination of glyphosate in groundwater using high performance liquid chromatography and solid-phase extraction after derivatization

    Directory of Open Access Journals (Sweden)

    Valdir Eduardo Olivo

    2015-04-01

    Full Text Available The intensive use of pesticides in agriculture has prompted researchers to develop new methods for identifying these pollutants in water. This study sought to validate a high performance liquid chromatography (HPLC method to determine the concentration of the pesticide glyphosate in groundwater samples by using solid-phase extraction (SPE filters after derivatization with chloroformate 9-fluorenylmethoxycarbonyl (FMOC-Cl. For the HPLC method, we evaluated the following main validation parameters: linearity, specificity, precision, accuracy, robustness, and limits of detection and quantification. After validation of the method, we determined the concentration of glyphosate in samples from thirteen deep, tubular wells distributed in urban and rural areas in Chapecó, SC, Brazil. The solvent used in the extraction of excess FMOC-Cl was dichloromethane and subsequently filtration was performed on C18 SPE, and injected into the chromatograph column in amino polymer with fluorescence detection. The analytical curve made in ultrapure water was linear, with a correlation coefficient of 0.99. The limits of detection and quantification were 0.24 and 0.07 µg L-1, respectively. Recovery tests in natural waters ranged from 90.37 to 101.70%. Glyphosate was detected in 5 of the thirteen wells evaluated. The highest concentration of glyphosate (6.80 µg L-1 was detected in a countryside well, near the municipal water supply. Despite the low levels of glyphosate detected in our study, any amount present in groundwater samples is worrisome, as these molecules have low ground mobility.

  2. The three-dimensional model for helical columns on type-J synchronous counter-current chromatography.

    Science.gov (United States)

    Guan, Y H; van den Heuvel, Remco

    2011-08-05

    Unlike the existing 2-D pseudo-ring model for helical columns undergoing synchronous type-J planetary motion of counter-current chromatograph (CCC), the 3-D "helix" model developed in this work shows that there is a second normal force (i.e. the binormal force) applied virtually in the axial direction of the helical column. This force alternates in the two opposite directions and intensifies phase mixing with increasing the helix angle. On the contrary, the 2-D spiral column operated on the same CCC device lacks this third-dimensional mixing force. The (principal) normal force quantified by this "helix" model has been the same as that by the pseudo-ring model. With β>0.25, this normal centrifugal force has been one-directional and fluctuates cyclically. Different to the spiral column, this "helix" model shows that the centrifugal force (i.e. the hydrostatic force) does not contribute to stationary phase retention in the helical column. Between the popular helical columns and the emerging spiral columns for type-J synchronous CCC, this work has thus illustrated that the former is associated with better phase mixing yet poor retention for the stationary phase whereas the latter has potential for better retention for the stationary phase yet poor phase mixing. The methodology developed in this work may be regarded as a new platform for designing optimised CCC columns for analytical and engineering applications. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Optimal synthesis and design of extractive distillation systems for bioethanol separation: From simple to complex columns

    DEFF Research Database (Denmark)

    Errico, M.; Rong, B. G.; Tola, G.

    2013-01-01

    Bioethanol has been considered as a green fuel and a valid alternative to reduce the dependence on fossil distillates. The development of an optimal separation process is considered as a key element in the design of an efficient process able to be cost effective and competitive. Despite many....... The subspace of simple distillation configurations was generated considering the possibility to employ partial or total condensers to transfer the non-product mixtures between the columns, moreover different numbers of columns are considered. Once the most promising sequences are obtained, the complex columns...... considering the total condenser and reboiler duty as energy index. The capital costs and the solvent consumption are also taken into account in the final selection. Among all the complex configurations considered the two-column sequence can reduce the capital cost above 10% compared to the best simple column...

  4. Molecularly imprinted macroporous monoliths for solid-phase extraction: Effect of pore size and column length on recognition properties.

    Science.gov (United States)

    Vlakh, E G; Stepanova, M A; Korneeva, Yu M; Tennikova, T B

    2016-09-01

    The series of macroporous monolithic molecularly imprinted monoliths differed by pore size, column length (volume) and amount of template used for imprinting was synthesized using methacrylic acid and glycerol dimethacrylate as co-monomers and antibiotic ciprofloxacin as a template. The prepared monoliths were characterized regarding to their permeability, pore size, porosity, and resistance to the flow of a mobile phase. The surface morphology was also analyzed. The slight dependence of imprinting factor on flow rate, as well as its independence on pore size of macroporous molecularly imprinted monolithic media was observed. The column obtained at different conditions exhibited different affinity of ciprofloxacin to the imprinted sites that was characterized with Kdiss values in the range of 10(-5)-10(-4)M. The solid-phase extraction of ciprofloxacin from such biological liquids as human blood serum, human urine and cow milk serum was performed using the developed monolithic columns. In all cases, the extraction was found to be 95.0-98.6%. Additionally, the comparison of extraction of three fluoroqinolone analogues, e.g. ciprofloxacin, levofloxacin and moxifloxacin, from human blood plasma was carried out. Contrary to ciprofloxacin extracted with more than 95%, this parameter did not exceed 40% for its analogues. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Novel materials and methods for solid-phase extraction and liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, Diana [Iowa State Univ., Ames, IA (United States)

    1997-06-24

    This report contains a general introduction which discusses solid-phase extraction and solid-phase micro-extraction as sample preparation techniques for high-performance liquid chromatography, which is also evaluated in the study. This report also contains the Conclusions section. Four sections have been removed and processed separately: silicalite as a sorbent for solid-phase extraction; a new, high-capacity carboxylic acid functionalized resin for solid-phase extraction; semi-micro solid-phase extraction of organic compounds from aqueous and biological samples; and the high-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

  6. The application of extraction chromatography for analysis of alkali and alkaline earth uranates

    International Nuclear Information System (INIS)

    Tomazic, B.; Cukovic, M.

    1978-01-01

    A method for rapid analysis of alkali and alkaline earth uranates is proposed. The method is based on the use of an HDEHP extraction chromatographic column, which makes possible quantitative separations of alkaline earth ions from macroamounts of uranium(VI). Composition of alkaline earth uranates, based on regression analysis, are presented. The results, which show that under the given experimental conditions alkaline earth triuranates precipitate, are in good agreement with previous data from same laboratory. In addition the HDEHP extraction chromatographic column can be suggested as a tool for separation of representative fission products from irradiated uranium for the purpose of determination of the burn-up factor of nuclear reactor materials. (T.G.)

  7. Extraction of red cabbage anthocyanins: optimization of the operation conditions of the column process

    Directory of Open Access Journals (Sweden)

    Marcelo Fonseca Xavier

    2008-02-01

    Full Text Available The aim of this work was to extract anthocyanins from the red cabbage. Batch studies under several extraction conditions indicated that acetic acid in aqueous solution (10% V/V was the best solvent, used in the proportion of 0.25 g of red cabbage mL-1. At this condition, column assays were carried out to evaluate the influence of the ionic force, pH, solvent flow rate, recirculated volume of red cabbage juice and the mass of red cabbage. Results showed that the pH, recirculation and mass of red cabbage had statistically significant effects, where the optimum operation conditions found for the process were pH 2.3, recirculation volume of the solvent 0.83 L and mass of red cabbage 50 g.Desde os primórdios dos tempos as antocianinas são extraídas de vegetais, mas avanços que garantam um processo viável e rentável exigem conhecimento, quantificação e controle das condições de operação. Estudos em batelada sob várias condições de extração indicaram que ácido acético em solução aquosa (10% V/V foi o melhor solvente, quando usado na proporção de 0,25 g de repolho roxo mL-1. Nesta condição de operação foram feitos ensaios em coluna para avaliar a influência da força iônica, pH, taxa de escoamento do solvente, volume recirculado da solução de extração e massa de repolho roxo. Os resultados mostraram que o pH, recirculação e massa de repolho foram estatisticamente significativos, e as condições ótimas de operação encontradas para o processo foram pH 2,3, volume de solvente recirculado de 0,83 L e massa de repolho roxo igual a 50g.

  8. Liquid Chromatography with Post-Column Reagent Addition of Ammonia in Methanol Coupled to Negative Ion Electrospray Ionization Tandem Mass Spectrometry for Determination of Phenoxyacid Herbicides and their Degradation Products in Surface Water

    Directory of Open Access Journals (Sweden)

    Michele L. Etter

    2010-02-01

    Full Text Available A new liquid chromatography (LC-negative ion electrospray ionization (ESI–tandem mass spectrometry (MS/MS method with post-column addition of ammonia in methanol has been developed for the analysis of acid herbicides: 2,4-dichlorophenoxy ace- tic acid, 4-chloro-o-tolyloxyacetic acid, 2-(2-methyl-4-chlorophenoxybutyric acid, mecoprop, dichlorprop, 4-(2,4-dichlorophenoxy butyric acid, 2,4,5-trichlorophenoxy propionic acid, dicamba and bromoxynil, along with their degradation products: 4-chloro-2- methylphenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol and 3,5-dibromo-4-hydroxybenzoic acid. The samples were extracted from the surface water matrix using solid-phase extraction (SPE with a polymeric sorbent and analyzed with LC ESI- with selected reaction monitoring (SRM using a three-point confirmation approach. Chromatography was performed on a Zorbax Eclipse XDB-C18 (50 × 4.6 mm i.d., 1.8 µm with a gradient elution using water-methanol with 2 mM ammonium acetate mobile phase at a flow rate of 0.15 mL/min. Ammonia in methanol (0.8 M was added post-column at a flow rate of 0.05 mL/min to enhance ionization of the deg- radation products in the MS source. One SRM transition was used for quantitative analysis while the second SRM along with the ratio of SRM1/SRM2 within the relative standard deviation determined by standards for each individual pesticide and retention time match were used for confirmation. The standard deviation of ratio of SRM1/SRM2 obtained from standards run on the day of analysis for different phenoxyacid herbicides ranged from 3.9 to 18.5%. Limits of detection (LOD were between 1 and 15 ng L-1 and method detection limits (MDL with strict criteria requiring

  9. Behaviour analysis of uranium purification pilot plant taking into consideration the incorporation of a second column of extraction in the process flow chart

    International Nuclear Information System (INIS)

    Souza Barbosa, E.M. de.

    1979-01-01

    This work analyses the effect of the incorporation of a second column of extraction by solvents in pulsed plate columns in the Process of Uranium Purification. Operating with the aqueous phase of washing this second column of extraction recovers the dragged Uranium, increasing the efficiency of the process. The experiments were carried out in the display unit of Uranium purification in the Institute of Energetic and Nuclear Researches in Sao Paulo, where the dimension and the performance were studied with the following parameters: real increase in the efficiency and decontamination in the process. An efficiency superior to 98% in mass was obtained against 84,6% in the conventional process. With a performance similar to the first column of extract on the decontamination, about 99%, obtained in this column, maintained the grade of nuclear purity peculiar to the Process of Uranium Purification by solvents in pulsed plate columns. (author) [pt

  10. Optimization of focused ultrasonic extraction of propellant components determined by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Fryš, Ondřej; Česla, Petr; Bajerová, Petra; Adam, Martin; Ventura, Karel

    2012-09-15

    A method for focused ultrasonic extraction of nitroglycerin, triphenyl amine and acetyl tributyl citrate presented in double-base propellant samples following by the gas chromatography/mass spectrometry analysis was developed. A face-centered central composite design of the experiments and response surface modeling was used for optimization of the time, amplitude and sample amount. The dichloromethane was used as the extractant solvent. The optimal extraction conditions with respect to the maximum yield of the lowest abundant compound triphenyl amine were found at the 20 min extraction time, 35% amplitude of ultrasonic waves and 2.5 g of the propellant sample. The results obtained under optimal conditions were compared with the results achieved with validated Soxhlet extraction method, which is typically used for isolation and pre-concentration of compounds from the samples of explosives. The extraction yields for acetyl tributyl citrate using both extraction methods were comparable; however, the yield of ultrasonic extraction of nitroglycerin and triphenyl amine was lower than using Soxhlet extraction. The possible sources of different extraction yields are estimated and discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Conventional and narrow bore short capillary columns with cyclodextrin derivatives as chiral selectors to speed-up enantioselective gas chromatography and enantioselective gas chromatography-mass spectrometry analyses.

    Science.gov (United States)

    Bicchi, Carlo; Liberto, Erica; Cagliero, Cecilia; Cordero, Chiara; Sgorbini, Barbara; Rubiolo, Patrizia

    2008-11-28

    The analysis of complex real-world samples of vegetable origin requires rapid and accurate routine methods, enabling laboratories to increase sample throughput and productivity while reducing analysis costs. This study examines shortening enantioselective-GC (ES-GC) analysis time following the approaches used in fast GC. ES-GC separations are due to a weak enantiomer-CD host-guest interaction and the separation is thermodynamically driven and strongly influenced by temperature. As a consequence, fast temperature rates can interfere with enantiomeric discrimination; thus the use of short and/or narrow bore columns is a possible approach to speeding-up ES-GC analyses. The performance of ES-GC with a conventional inner diameter (I.D.) column (25 m length x 0.25 mm I.D., 0.15 microm and 0.25 microm d(f)) coated with 30% of 2,3-di-O-ethyl-6-O-tert-butyldimethylsilyl-beta-cyclodextrin in PS-086 is compared to those of conventional I.D. short column (5m length x 0.25 mm I.D., 0.15 microm d(f)) and of different length narrow bore columns (1, 2, 5 and 10 m long x 0.10 mm I.D., 0.10 microm d(f)) in analysing racemate standards of pesticides and in the flavour and fragrance field and real-world-samples. Short conventional I.D. columns gave shorter analysis time and comparable or lower resolutions with the racemate standards, depending mainly on analyte volatility. Narrow-bore columns were tested under different analysis conditions; they provided shorter analysis time and resolutions comparable to those of conventional I.D. ES columns. The narrow-bore columns offering the most effective compromise between separation efficiency and analysis time are the 5 and 2m columns; in combination with mass spectrometry as detector, applied to lavender and bergamot essential oil analyses, these reduced analysis time by a factor of at least three while separation of chiral markers remained unaltered.

  12. Optimization of hydrophilic interaction liquid chromatography/mass spectrometry and development of solid-phase extraction for the determination of paralytic shellfish poisoning toxins.

    Science.gov (United States)

    Turrell, Elizabeth; Stobo, Lesley; Lacaze, Jean-Pierre; Piletsky, Sergey; Piletska, Elena

    2008-01-01

    The combination of hydrophilic interaction liquid chromatography (HILIC) and liquid chromatography/mass spectrometry (LC/MS) for the determination of paralytic shellfish poisoning (PSP) toxins has been proposed for use in routine monitoring of shellfish. In this study, methods for the detection of multiple PSP toxins [saxitoxin (STX), neosaxitoxin (NEO), decarbamoyl saxitoxin (dcSTX), decarbamoyl neosaxitoxin (dcNEO), gonyautoxins 1-5 (GTX1, GTX2, GTX3, GTX4, GTX5), decarbamoyl gonyautoxins (dcGTX2 and dcGTX3), and the N-sulfocarbamoyl C toxins (C1 and C2)] were optimized using single (MS) and triple quadrupole (MS/MS) instruments. Chromatographic separation of the toxins was achieved by using a TSK-gel Amide-80 analytical column, although superior chromatography was observed through application of a ZIC-HILIC column. Preparative procedures used to clean up shellfish extracts and concentrate PSP toxins prior to analysis were investigated. The capacity of computationally designed polymeric (CDP) materials and HILIC solid-phase extraction (SPE) cartridges to retain highly polar PSP toxins was explored. Three CDP materials and 2 HILIC cartridges were assessed for the extraction of PSP toxins from aqueous solution. Screening of the CDPs showed that all tested polymers adsorbed PSP toxins. A variety of elution procedures were examined, with dilute 0.01% acetic acid providing optimum recovery from a CDP based on 2-(trifluoromethyl)acrylic acid as the monomer. ZIC-HILIC SPE cartridges were superior to the PolyLC equivalent, with recoveries ranging from 70 to 112% (ZIC-HILIC) and 0 to 90% (PolyLC) depending on the PSP toxin. It is proposed that optimized SPE and HILIC-MS methods can be applied for the quantitative determination of PSP toxins in shellfish.

  13. Sequential injection chromatography with post-column reaction/derivatization for the determination of transition metal cations in natural water samples.

    Science.gov (United States)

    Horstkotte, Burkhard; Jarošová, Patrícia; Chocholouš, Petr; Sklenářová, Hana; Solich, Petr

    2015-05-01

    In this work, the applicability of Sequential Injection Chromatography for the determination of transition metals in water is evaluated for the separation of copper(II), zinc(II), and iron(II) cations. Separations were performed using a Dionex IonPAC™ guard column (50mm×2mm i.d., 9 µm). Mobile phase composition and post-column reaction were optimized by modified SIMPLEX method with subsequent study of the concentration of each component. The mobile phase consisted of 2,6-pyridinedicarboxylic acid as analyte-selective compound, sodium sulfate, and formic acid/sodium formate buffer. Post-column addition of 4-(2-pyridylazo)resorcinol was carried out for spectrophotometric detection of the analytes׳ complexes at 530nm. Approaches to achieve higher robustness, baseline stability, and detection sensitivity by on-column stacking of the analytes and initial gradient implementation as well as air-cushion pressure damping for post-column reagent addition were studied. The method allowed the rapid separation of copper(II), zinc(II), and iron(II) within 6.5min including pump refilling and aspiration of sample and 1mmol HNO3 for analyte stacking on the separation column. High sensitivity was achieved applying an injection volume of up to 90µL. A signal repeatability of<2% RSD of peak height was found. Analyte recovery evaluated by spiking of different natural water samples was well suited for routine analysis with sub-micromolar limits of detection. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Systematic evaluation of commercially available ultra-high performance liquid chromatography columns for drug metabolite profiling: optimization of chromatographic peak capacity.

    Science.gov (United States)

    Dubbelman, Anne-Charlotte; Cuyckens, Filip; Dillen, Lieve; Gross, Gerhard; Hankemeier, Thomas; Vreeken, Rob J

    2014-12-29

    The present study investigated the practical use of modern ultra-high performance liquid chromatography (UHPLC) separation techniques for drug metabolite profiling, aiming to develop a widely applicable, high-throughput, easy-to-use chromatographic method, with a high chromatographic resolution to accommodate simultaneous qualitative and quantitative analysis of small-molecule drugs and metabolites in biological matrices. To this end, first the UHPLC system volume and variance were evaluated. Then, a mixture of 17 drugs and various metabolites (molecular mass of 151-749Da, logP of -1.04 to 6.7), was injected on six sub-2μm particle columns. Five newest generation core shell technology columns were compared and tested against one column packed with porous particles. Two aqueous (pH 2.7 and 6.8) and two organic mobile phases were evaluated, first with the same flow and temperature and subsequently at each column's individual limit of temperature and pressure. The results demonstrated that pre-column dead volume had negligible influence on the peak capacity and shape. In contrast, a decrease in post-column volume of 57% resulted in a substantial (47%) increase in median peak capacity and significantly improved peak shape. When the various combinations of stationary and mobile phases were used at the same flow rate (0.5mL/min) and temperature (45°C), limited differences were observed between the median peak capacities, with a maximum of 26%. At higher flow though (up to 0.9mL/min), a maximum difference of almost 40% in median peak capacity was found between columns. The finally selected combination of solid-core particle column and mobile phase composition was chosen for its selectivity, peak capacity, wide applicability and peak shape. The developed method was applied to rat hepatocyte samples incubated with the drug buspirone and demonstrated to provide a similar chromatographic resolution, but a 6 times higher signal-to-noise ratio than a more traditional UHPLC

  15. [Intersection point rule for the retention value with mobile phase composition and boiling point of the homologues and chlorobenzenes in soil leaching column chromatography].

    Science.gov (United States)

    Xu, F; Liang, X; Lin, B; Su, F

    1999-03-01

    Based on the linear retention equation of the logarithm of the capacity factor (logk') vs. the methanol volume fraction (psi) of aqueous binary mobile phase in soil leaching column chromatography, the intersection point rule for the logk' of homologues and weak polar chlorobenzenes, with psi, as well as with boiling point, has been derived due to existence of the similar interactions among solutes of the same series, stationary phase (soil) and eluent (methanol-water). These rules were testified by experimental data of homologues (n-alkylbenzenes, methylbenzenes) and weak polar chlorobenzenes.

  16. Potential of capillary-column-switching liquid chromatography-tandem mass spectrometry for the quantitative trace analysis of small molecules. Application to the on-line screening of drugs in water.

    Science.gov (United States)

    Pitarch, Elena; Hernandez, Felix; ten Hove, Jan; Meiring, Hugo; Niesing, Willem; Dijkman, Ellen; Stolker, Linda; Hogendoorn, Elbert

    2004-03-26

    We have investigated the potential of capillary-column-switching liquid chromatography coupled to tandem mass spectrometry (cLC-MS-MS) for the quantitative on-line trace analysis of target compounds in aqueous solutions. The technical design of the nano-scale cLC system developed at our Institute for peptide and protein identification has been tested and evaluated for the direct trace analysis of drugs in water samples. Sulphametoxazole, bezafibrate, metoprolol, carbamazepine and bisoprolol occurring frequently in Dutch waters, were selected as test compounds. Adequate conditions for trapping, elution and MS-MS detection were investigated by employing laboratory made 200 microm i.d. capillary columns packed with 5 microm aqua C18 material. In the final cLC-MS-MS conditions, a 1 cm length trapping column and a 4 cm length analytical column were selected. Under these conditions, the target compounds could be directly determined in water down to a level of around 50 ng/l employing only 25 microl of water sample. Validation was done by recovery experiments in ground-, surface- and drinking-water matrices as well as by the analysis of water samples with incurred residues and previously analyzed with a conventional procedure involving off-line solid-phase extraction and narrow-bore LC with MS-MS detection. The new methodology provided recoveries (50-500 ng/l level) between 50 and 114% with RSDs (n = 3, each level) below 20% for most of the compounds. Despite the somewhat less analytical performance in comparison to the conventional procedure, the on-line approach of the new methodology is very suitable for screening of drugs in aqueous samples.

  17. Extraction chromatography of Am (III), Eu (III), Zn (II), and Cs (I), Using chromo sorb impregnated by 0..01 m 2-heptyl-2-methyl-nonanoic acid in benzene. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    El-naggar, H A; Ramadan, A; Abdel-Fattah, A [Nuclear chemistry Department, Hot laboratories Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    Extraction chromatography studies were carried out for Am(III), Eu(III), Zn(II), and Cs(I) using long carboxylic acid, 2-heptyl-2-methyl nonanoic acid in benzene as an extractant chromo sorb. This was selected to act as a solid support and it was impregnated with the extractant to obtain the stationary phase. The eluting agent used was 0.1 m H N O{sub 3}. The investigation included primarily the extraction chromatography of the individual elements concerned and their elution peaks which were plotted. Group separation of the four elements into two pairs was obtained Am-Eu, and Zn-Cs. A mixture of the four elements was loaded on the column to achieve practically such promising group separations. 5 figs.

  18. Extraction chromatography of Am (III), Eu (III), Zn (II), and Cs (I), Using chromo sorb impregnated by 0..01 m 2-heptyl-2-methyl-nonanoic acid in benzene. Vol. 3

    International Nuclear Information System (INIS)

    El-naggar, H.A.; Ramadan, A.; Abdel-Fattah, A.

    1996-01-01

    Extraction chromatography studies were carried out for Am(III), Eu(III), Zn(II), and Cs(I) using long carboxylic acid, 2-heptyl-2-methyl nonanoic acid in benzene as an extractant chromo sorb. This was selected to act as a solid support and it was impregnated with the extractant to obtain the stationary phase. The eluting agent used was 0.1 m H N O 3 . The investigation included primarily the extraction chromatography of the individual elements concerned and their elution peaks which were plotted. Group separation of the four elements into two pairs was obtained Am-Eu, and Zn-Cs. A mixture of the four elements was loaded on the column to achieve practically such promising group separations. 5 figs

  19. Metabolite Extraction from Saccharomyces cerevisiae for Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Rosebrock, Adam P; Caudy, Amy A

    2017-09-01

    Prior to mass spectrometric analysis, cellular small molecules must be extracted and separated from interfering components such as salts and culture medium. To ensure minimal perturbation of metabolism, yeast cells grown in liquid culture are rapidly harvested by filtration as described here. Simultaneous quenching of metabolism and extraction is afforded by immediate immersion in low-temperature organic solvent. Samples prepared using this method are suitable for a range of downstream liquid chromatography-mass spectrometry analyses and are stable in solvent for >1 yr at -80°C. © 2017 Cold Spring Harbor Laboratory Press.

  20. Determination of hexachlorobutadiene, pentachlorobenzene, and hexachlorobenzene in waste incineration fly ash using ultrasonic extraction followed by column cleanup and GC-MS analysis.

    Science.gov (United States)

    Zhang, Haiyan; Jiang, Lei; Zhou, Xin; Zeng, Tao; He, Zhiqiao; Huang, Xinwen; Chen, Jianmeng; Song, Shuang

    2018-03-01

    Hexachlorobutadiene (HCBD) was listed as a new controlling persistent organic pollutant in the Stockholm Convention because of its wide industrial applications and potential genotoxicity and carcinogenicity. However, only limited information exists on the release of HCBD from unintentional sources, such as waste incineration. Identification and quantification of HCBD in fly ash, one of the major outputs of waste incineration, is imperative. This work presents a simple method for determining HCBD in waste incineration fly ash based on ultrasonic extraction coupled with a silica gel-Florisil column cleanup followed by gas chromatography-mass spectrometry detection. Two typical persistent organic pollutants, pentachlorobenzene (PeCB) and hexachlorobenzene (HCB), were measured simultaneously. The parameters that influence the extraction efficiency and the quality of instrument detection were studied. Under the optimum experimental conditions, high sensitivity (detection limit 0.25-0.53 ng g -1 ), acceptable recoveries (64.0-71.4%) at spiking levels of 5-500 ng g -1 , and good repeatability [relative standard deviation (n = 3) of 14% or less] were achieved for all target analytes. The validation of this method was performed by analysis of six real fly ash samples from different waste incinerators in eastern China. The concentrations of HCBD detected in these samples (1.39-97.6 ng g -1 ) were comparable to those of PeCB (1.22-150 ng g -1 ) and HCB (0.82-120 ng g -1 ), indicating that the residual HCBD as well as PeCB and HCB in waste incineration fly ash should not be ignored. The results confirm for the first time that waste incineration is an unintentional source of HCBD in China. Graphical abstract An analytical method for hexachlorobutadiene, pentachlorobenzene, and hexachlorobenzene in fly ash from waste incineration. GC-MS gas chromatography-mass spectrometry, Ph-d10 phenanthrene-d 10 .

  1. Multi-target determination of organic ultraviolet absorbents in organism tissues by ultrasonic assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Peng, Xianzhi; Jin, Jiabin; Wang, Chunwei; Ou, Weihui; Tang, Caiming

    2015-03-06

    A sensitive and reliable method was developed for multi-target determination of 13 most widely used organic ultraviolet (UV) absorbents (including UV filters and UV stabilizers) in aquatic organism tissues. The organic UV absorbents were extracted using ultrasonic-assisted extraction, purified via gel permeation chromatography coupled with silica gel column chromatography, and determined by ultra-high performance liquid chromatography-tandem mass spectrometry. Recoveries of the UV absorbents from organism tissues mostly ranged from 70% to 120% from fish filet with satisfactory reproducibility. Method quantification limits were 0.003-1.0ngg(-1) dry weight (dw) except for 2-ethylhexyl 4-methoxycinnamate. This method has been applied to analysis of the UV absorbents in wild and farmed aquatic organisms collected from the Pearl River Estuary, South China. 2-Hydroxy-4-methoxybenzophenone and UV-P were frequently detected in both wild and farmed marine organisms at low ngg(-1)dw. 3-(4-Methylbenzylidene)camphor and most of the benzotriazole UV stabilizers were also frequently detected in maricultured fish. Octocrylene and 2-ethylhexyl 4-methoxycinnamate were not detected in any sample. This work lays basis for in-depth study about bioaccumulation and biomagnification of the UV absorbents in marine environment. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Improved method for the extraction and chromatographic analysis on a fused-core column of ellagitannins found in oak-aged wine.

    Science.gov (United States)

    Navarro, María; Kontoudakis, Nikolaos; Canals, Joan Miquel; García-Romero, Esteban; Gómez-Alonso, Sergio; Zamora, Fernando; Hermosín-Gutiérrez, Isidro

    2017-07-01

    A new method for the analysis of ellagitannins observed in oak-aged wine is proposed, exhibiting interesting advantages with regard to previously reported analytical methods. The necessary extraction of ellagitannins from wine was simplified to a single step of solid phase extraction (SPE) using size exclusion chromatography with Sephadex LH-20 without the need for any previous SPE of phenolic compounds using reversed-phase materials. The quantitative recovery of wine ellagitannins requires a combined elution with methanol and ethyl acetate, especially for increasing the recovery of the less polar acutissimins. The chromatographic method was performed using a fused-core C18 column, thereby avoiding the coelution of main ellagitannins, such as vescalagin and roburin E. However, the very polar ellagitannins, namely, the roburins A, B and C, still partially coeluted, and their quantification was assisted by the MS detector. This methodology also enabled the analysis of free gallic and ellagic acids in the same chromatographic run. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Cloud-Point Extraction Combined with Liquid Chromatography for the Determination of Ergosterol, a Natural Product with Diuretic Activity, in Rat Plasma, Urine, and Faeces

    Directory of Open Access Journals (Sweden)

    Dan-Qian Chen

    2013-01-01

    Full Text Available Ergosterol from many medicinal fungi has been demonstrated to possess a variety of pharmacological activities in vivo and in vitro. A new method based on cloud-point extraction has been developed, optimized and validated for the determination of ergosterol in rat plasma, urine and faeces by liquid chromatography. The non-ionic surfactant Triton X-114 was chosen as the extract solvent. The chromatographic separation was performed on an Inertsil ODS-3 analytical column with a mobile phase consisting of methanol and water (98 : 2, v/v at a flow rate of 1 mL/min. The methodology was validated completely. The results indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. The method was successfully applied to the pharmacokinetic studies of ergosterol in rats. The results indicate that the ergosterol levels in feces are much higher than those in plasma and urine of the rat.

  4. Chemical speciation of arsenic species in human blood serum by liquid chromatography using a phosphatidylcholine-coated ODS column with detection by ICP-MS

    International Nuclear Information System (INIS)

    Hasegawa, Takuya; Ishise, Jotaro; Fukumoto, Yasuharu; Matsuura, Hirotaka; Zhu, Yanbei; Umemura, Tomonari; Haraguchi, Hiroki; Yamamoto, Kazuhito; Naoe, Tomoki

    2007-01-01

    Chemical speciation of arsenic species in human blood serum was performed by high-performance liquid chromatography/inductively coupled plasma mass spectrometry (HPLC/ICP-MS) with direct sample injection, where an octadecylsilyl silica (ODS) column coated with phosphatidylcholine (PC) (hereafter known as 'PC-coated ODS column') was used as the separation column. In arsenic species analysis, a citrate buffer solution (pH 4.0) was used as the mobile phase, in which the following reagents were added: sodium 1-dodecanesulfonate (SDS), tetramethylammonium hydroxide (TMAH), which are ion-pair reagents to separate inorganic and organic arsenic species, and 3-[(3-cholamidopropyl)-dimethylammonio]-1-propane sulfonate (CHAPS), which is a protein-solubilizing agent to prevent adsorption of proteins on the column. As a result of optimization, five representative arsenic species spiked in human blood serum reference material could be separated from each other within 5 min on the PC-coated ODS column by elution with a 5 mM citrate buffer (pH 4.0) containing 5 mM SDS, 5 mM THAH, and 0.2 mM CHAPS. The detection limits obtained by ICP-MS were 3.1, 2.7, 4.5, 2.5, and 2.5 ng of As g -1 for arsenate (iAs V ), arsenite (iAs III ), monomethylarsonic acid (MMA), dimethylarsenic acid (DMA), and arsenobetaine (AB), respectively, when the injection volume was 20 μL. The present separation system was also applied to speciation analysis of arsenic species in human blood serum collected from a leukemia patient after therapeutic treatment with arsenic. (author)

  5. Analysis of bovine milk caseins on organic monolithic columns: an integrated capillary liquid chromatography-high resolution mass spectrometry approach for the study of time-dependent casein degradation.

    Science.gov (United States)

    Pierri, Giuseppe; Kotoni, Dorina; Simone, Patrizia; Villani, Claudio; Pepe, Giacomo; Campiglia, Pietro; Dugo, Paola; Gasparrini, Francesco

    2013-10-25

    Casein proteins constitute approximately 80% of the proteins present in bovine milk and account for many of its nutritional and technological properties. The analysis of the casein fraction in commercially available pasteurized milk and the study of its time-dependent degradation is of considerable interest in the agro-food industry. Here we present new analytical methods for the study of caseins in fresh and expired bovine milk, based on the use of lab-made capillary organic monolithic columns. An integrated capillary high performance liquid chromatography and high-resolution mass spectrometry (Cap-LC-HRMS) approach was developed, exploiting the excellent resolution, permeability and biocompatibility of organic monoliths, which is easily adaptable to the analysis of intact proteins. The resolution obtained on the lab-made Protein-Cap-RP-Lauryl-γ-Monolithic column (270 mm × 0.250 mm length × internal diameter, L × I.D.) in the analysis of commercial standard caseins (αS-CN, β-CN and κ-CN) through Cap-HPLC-UV was compared to the one observe using two packed capillary C4 columns, the ACE C4 (3 μm, 150 mm × 0.300 mm, L × I.D.) and the Jupiter C4 column (5 μm, 150 mm × 0.300 mm, L × I.D.). Thanks to the higher resolution observed, the monolithic capillary column was chosen for the successive degradation studies of casein fractions extracted from bovine milk 1-4 weeks after expiry date. The comparison of the UV chromatographic profiles of skim, semi-skim and whole milk showed a major stability of whole milk towards time-dependent degradation of caseins, which was further sustained by high-resolution analysis on a 50-cm long monolithic column using a 120-min time gradient. Contemporarily, the exact monoisotopic and average molecular masses of intact αS-CN and β-CN protein standards were obtained through high resolution mass spectrometry and used for casein identification in Cap-LC-HRMS analysis. Finally, the proteolytic degradation of β-CN in skim milk

  6. Application of extraction chromatography to the recovery of neptunium, plutonium and americium from an industrial waste

    International Nuclear Information System (INIS)

    Madic, C.; Kertesz, C.; Sontag, R.; Koehly, G.

    1980-01-01

    A pilot scale investigation was made to evaluate the possible application of the extraction chromatographic method (LLC) to the partitioning of alpha emitters from liquid wastes containing traces of transuranium elements. A secondary purpose was to obtain pure Am0 2 , which is used to produce alpha, gamma, and neutron sources. The process developed for alpha partitioning consists essentially of the extraction of macro amounts of uranium with 30% TBP in dodecane in mixer-settlers, then coextraction of Np-237, Pu-239, and Am-241 by LLC on a macro column filled with di-n-hexyl-octoxy-methyl-phosphine oxide (POX.11) adsorbed on an inert support. In each run about 200 liters of initial waste are decontaminated of alpha emitters. The loading step is followed by selective elution of americium, neptunium, and plutonium. The americium eluate is then subjected to the following operations: (1) separation of Am from Fe and Cd by LLC on a TBP column and (2) separation of Am from lanthanide traces by LLC on an HD(DiBM)P column after oxidation of Am(III) to Am(VI). The Am in the eluate is subsequently reduced to Am(III) and precipitated as oxalate with oxalic acid. The oxalate is then filtered and calcined to yield pure AmO 2

  7. EXTRACTION AND QUANTITATIVE ANALYSIS OF ELEMENTAL SULFUR FROM SULFIDE MINERAL SURFACES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY. (R826189)

    Science.gov (United States)

    A simple method for the quantitative determination of elemental sulfur on oxidized sulfide minerals is described. Extraction of elemental sulfur in perchloroethylene and subsequent analysis with high-performance liquid chromatography were used to ascertain the total elemental ...

  8. Multi-podant diglycolamides and room temperature ionic liquid impregnated resins: An excellent combination for extraction chromatography of actinides.

    Science.gov (United States)

    Gujar, R B; Ansari, S A; Verboom, W; Mohapatra, P K

    2016-05-27

    Extraction chromatography resins, prepared by impregnating two multi-podant diglycolamide ligands, viz. diglycolamide-functionalized calix[4]arene (C4DGA) and tripodal diglycolamide (T-DGA) dissolved in the room temperature ionic liquid 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)amide (RTIL: C4mimTf2N) on Chromosorb-W (an inert solid support), gave excellent results for the removal of trivalent actinides from acidic waste solutions. Distribution coefficient measurements on several metal ions showed selective sorption of Am(III) over hexavalent uranyl ions and other fission product elements such as strontium and cesium. The sorbed metal ions could be efficiently desorbed with a complexing solution containing guanidine carbonate and EDTA buffer. The sorption of Am(III) on both resins followed pseudo-second order rate kinetics with rate constants of 1.37×10(-6) and 6.88×10(-7)g/cpmmin for T-DGA and C4DGA resins, respectively. The metal sorption on both resins indicated the Langmuir monolayer chemisorption phenomenon with Eu(III) sorption capacities of 4.83±0.21 and 0.52±0.05mg per g of T-DGA and C4DGA resins, respectively. The results of column studies show that these resins are of interest for a possible application for the recovery of hazardous trivalent actinides from dilute aqueous solutions. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. High performance liquid chromatography column efficiency enhancement by zero dead volume recycling and practical approach using park and recycle arrangement.

    Science.gov (United States)

    Minarik, Marek; Franc, Martin; Minarik, Milan

    2018-06-15

    A new instrumental approach to recycling HPLC is described. The concept is based on fast reintroduction of incremental peak sections back onto the separation column. The re-circulation is performed within a closed loop containing only the column and two synchronized switching valves. By having HPLC pump out of the cycle, the method minimizes peak broadening due to dead volume. As a result the efficiency is dramatically increased allowing for the most demanding analytical applications. In addition, a parking loop is employed for temporary storage of analytes from the middle section of the separated mixture prior to their recycling. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Simultaneous analysis of steviol and steviol glycosides by liquid chromatography with ultraviolet detection on a mixed-mode column: application to Stevia plant material and Stevia-containing dietary supplements.

    Science.gov (United States)

    Jaworska, Karolina; Krynitsky, Alexander J; Rader, Jeanne I

    2012-01-01

    Simultaneous separation of steviol and steviol glycosides is challenging because of differences in their polarity and chemical structure. In this study, simultaneous analysis of steviol and steviol glycosides was achieved by LC with UV detection using a mixed-mode RP weak anion exchange chromatography column. Steviol and seven steviol glycosides were analyzed on an Acclaim Mixed-Mode Wax-1 (Dionex) column with a linear gradient of deionized water adjusted to pH 3.00 with phosphoric acid and acetonitrile. The extraction was performed by sonicating dry plant material at 40 degreesC in acetonitrile-water (30 + 70, v/v). LOQ values (mg/g dry weight of plant material) were rebaudioside B, 0.50; steviol, 0.70, dulcoside A, 1.0; steviolbioside, 1.2; stevioside and rebaudioside C, 2.0; rebaudioside D, 3.3; and rebaudioside A, 5.0. The method demonstrated suitable performance for all analytes tested with respect to accuracy (mean recoveries 95-99%), intraday and interday precision for retention times (0.070-0.28% and 0.33-1.0% RSD, respectively), and linearity. The method was used to authenticate steviol glycosides in several samples of Stevia plant material as well as to quantitate steviol glycosides in dietary supplements containing Stevia.

  11. Sequential Injection Chromatography with an Ultra-short Monolithic Column for the Low-Pressure Separation of α-Tocopherol and γ-Oryzanol in Vegetable Oils and Nutrition Supplements.

    Science.gov (United States)

    Thaithet, Sujitra; Kradtap Hartwell, Supaporn; Lapanantnoppakhun, Somchai

    2017-01-01

    A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.

  12. Quantitative determination of flavonoids by column high-performance liquid chromatography with mass spectrometry and ultraviolet absorption detection in Artemisia afra and comparative studies with various species of Artemisia plants.

    Science.gov (United States)

    Avula, Bharathi; Wang, Yan-Hong; Smillie, Troy J; Mabusela, Wilfred; Vincent, Leszek; Weitz, Frans; Khan, Ikhlas A

    2009-01-01

    A simple and specific analytical method for the quantitative determination of flavonoids from the aerial parts of the Artemisia afra plant samples was developed. By column high-performance liquid chromatography (HPLC) with UV absorption and mass spectrometry (MS) detection, separation was achieved on a reversed-phase octadecylsilyl (C18) column with water, methanol, and acetonitrile, all containing 0.1% acetic acid, as the mobile phase. These methods were used to analyze various species of Artemisia plant samples. The wavelength used for quantification of flavonoids with the diode array detector was 335 nm. The limits of detection (LOD) by HPLC/MS were found to be 7.5, 7.5, 10, 2.0, and 2.0 ng/mL; and by LC-UV the LODs were 500, 500, 500, 300, and 300 ng/mL for apigenin, chrysoeriol, tamarixetin, acacetin, and genkwanin, respectively. The HPLC/MS method was found to be 50-150 times more sensitive than the HPLC-UV method. HPLC/MS coupled with an electrospray ionization interface is described for the identification and quantification of flavonoids in various plant samples. This method involved the use of the [M+H]+ ions of the compounds at mass-to-charge ratio of 1.0606, 301.0712, 317.0661, 285.0763, and 285.0763 (calculated mass), respectively, in the positive ion mode with extractive ion monitoring.

  13. Determination of selected azaarenes in water by bonded-phase extraction and liquid chromatography

    Science.gov (United States)

    Steinheimer, T.R.; Ondrus, M.G.

    1986-01-01

    A method for the rapid and simple quantitative determination of quinoline, isoquinoline, and five selected three-ring azaarenes in water has been developed. The azaarene fraction is separated from its carbon analogues on n-octadecyl packing material by edition with acidified water/acetonitrile. Concentration as great as 1000-fold is achieved readily. Instrumental analysis involves high-speed liquid chromatography on flexible-walled, wide-bore columns with fluorescence and ultraviolet detection at several wavelengths employing filter photometers in series. Method-validation data is provided as azaarene recovery efficiency from fortified samples. Distilled water, river water, contaminated ground water, and secondary-treatment effluent have been tested. Recoveries at part-per-billion levels are nearly quantitative for the three-ring compounds, but they decrease for quinoline and isoquinoline. ?? 1986 American Chemical Society.

  14. Hard cap espresso extraction and liquid chromatography determination of bioactive compounds in vegetables and spices.

    Science.gov (United States)

    Martinez-Sena, María Teresa; de la Guardia, Miguel; Esteve-Turrillas, Francesc A; Armenta, Sergio

    2017-12-15

    A new analytical procedure, based on liquid chromatography with diode array and fluorescence detection, has been proposed for the determination of bioactive compounds in vegetables and spices after hard cap espresso extraction. This novel extraction system has been tested for the determination of capsaicin and dihydrocapsaicin from fresh chilli and sweet pepper, piperine from ground pepper, curcumin from turmeric and curry, and myristicin from nutmeg. Extraction efficiency was evaluated by using acetonitrile:water and ethanol:water mixtures. The proposed method allows the extraction of samples with 100mL of 60% (v/v) ethanol in water. The obtained limits of quantification for the proposed procedure ranged from 0.07 to 0.30mgg -1 and results were statistically comparable with those obtained by ultrasound assisted extraction. Hard cap espresso machines offer a fast, effective and quantitative tool for the extraction of bioactive compounds from food samples with an extraction time lower than 30s, using a global available and low cost equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. In-tube solid-phase microextraction based on NH2-MIL-53(Al)-polymer monolithic column for online coupling with high-performance liquid chromatography for directly sensitive analysis of estrogens in human urine.

    Science.gov (United States)

    Luo, Xialin; Li, Gongke; Hu, Yufei

    2017-04-01

    In this work, a novel NH 2 -MIL-53(Al) incorporated poly(styrene-divinylbenzene-methacrylic acid) (poly(St-DVB-MAA)) monolith was prepared via chemical fabrication. Moreover, it has been efficiently applied to the in-tube solid-phase microextraction (SPME) for online coupling with high-performance liquid chromatography (HPLC) to the direct determination of five estrogens in human urine samples. The NH 2 -MIL-53(Al)-polymer monolith was suitable for in-tube SPME owing to its good permeability, high extraction efficiency, chemical stability, good reproducibility and long lifetime. The extraction conditions including extraction solvent, pH of sample solution, flow rate of extraction and desorption, and desorption volume were investigated. Under the optimum conditions, the enrichment factors were 180-304 and saturated amounts of extraction were 2326-21393 pmol for estriol, 17β-estradiol, estrone, ethinyl estradiol and progesterone, respectively. The adsorption mechanism was also explored which contributed to its strong extraction to target compounds. The proposed method had low limit of detection (2.0-40ng/L) and good linearity (with R 2 between 0.9908 and 0.9978). Four endogenous estrogens were detected in urine samples and the recoveries of all five analytes were ranged from 75.1-120% with relative standard deviations (RSDs) less than 8.7%. The results showed that the proposed online SPME-HPLC method based on NH 2 -MIL-53(Al)-polymer monolithic column was highly sensitive for directly monitoring trace amount of estrogens in human urine sample. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Determination of carbon isotope ratios for honey samples by means of a liquid chromatography/isotope ratio mass spectrometry system coupled with a post-column pump.

    Science.gov (United States)

    Kawashima, Hiroto; Suto, Momoka; Suto, Nana

    2018-05-20

    Liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) has been used to authenticate and trace products such as honey, wine, and lemon juice, and compounds such as caffeine and pesticides. However, LC/IRMS has several disadvantages, including the high cost of the CO 2 membrane and blocking by solidified sodium persulfate. Here, we developed an improved system for determining carbon isotope ratios by LC/IRMS. The main improvement was the use of a post-column pump. Using the improved system, we determined δ 13 C values for glucose with high accuracy and precision (0.1‰ and 0.1‰, respectively; n = 3). The glucose, fructose, disaccharide, trisaccharide, and organic acid constituents of the honey samples were analyzed by LC/IRMS. The δ 13 C values for glucose, fructose, disaccharides, trisaccharides, and organic acids ranged from -27.0 to -24.2‰, -26.8 to -24.0‰, -28.8 to -24.0‰, -27.8 to -22.8‰, and -30.6 to -27.4‰, respectively. The analysis time was 1/3-1/2 the times required for analysis by previously reported methods. The column flow rate could be arbitrarily adjusted with the post-column pump. We applied the improved method to 26 commercial honey samples. Our results can be expected to be useful for other researchers who use LC/IRMS. This article is protected by copyright. All rights reserved.

  17. Thorough investigation of the retention mechanisms and retention behavior of amides and sulfonamides on amino column in hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Jovanović, Marko; Stojanović, Biljana Jančić

    2013-08-02

    In this paper detailed analysis of a mixture of four amides (tropicamide, nicotinamide, tiracetam, and piracetam) and six sulfonamides (sulfanilamide, sulfacetamide, sulfamethoxazole, sulfafurazole, furosemide, and bumetanide) on aminopropyl column in hydrophilic interaction chromatography (HILIC) was carried out. Since, there are no papers on the topic of the assessment of the contribution of ion-exchange retention mechanism involved in the separation of the acidic compounds on aminopropyl column in HILIC mode, the authors utilized the retention data of the acidic sulfonamides for this purpose. Next, broad range of the aqueous buffer concentrations in the mobile phase was examined providing the separation under either HILIC or RP conditions. Turning points between these two mechanisms were determined and then the fitting of the experimental data in the localized and non-localized adsorption models in both RP and HILIC regions was assessed. Since not many papers in the literature were dealing with the estimation of factor influence on the retention behavior of neutral and acidic compounds on aminopropyl column in HILIC, Box-Behnken design and Response Surface Methodology were applied. On the basis of the obtained data, ten quadratic models were proposed and their adequacy was confirmed using ANOVA test. Furthermore, retention data was graphically evaluated by the construction of 3D response surface plots. Finally, good predictive ability of the suggested models was proved with five additional verification experiments. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Extraction of three bioactive diterpenoids from Andrographis paniculata: effect of the extraction techniques on extract composition and quantification of three andrographolides using high-performance liquid chromatography.

    Science.gov (United States)

    Kumar, Satyanshu; Dhanani, Tushar; Shah, Sonal

    2014-10-01

    Andrographis paniculata (Burm.f.) wall.ex Nees (Acanthaceae) or Kalmegh is an important medicinal plant finding uses in many Ayurvedic formulations. Diterpenoid compounds andrographolides (APs) are the main bioactive phytochemicals present in leaves and herbage of A. paniculata. The efficiency of supercritical fluid extraction (SFE) using carbon dioxide was compared with the solid-liquid extraction techniques such as solvent extraction, ultrasound-assisted solvent extraction and microwave-assisted solvent extraction with methanol, water and methanol-water as solvents. Also a rapid and validated reverse-phase high-performance liquid chromatography-diode array detection method was developed for the simultaneous determination of the three biologically active compounds, AP, neoandrographolide and andrograpanin, in the extracts of A. paniculata. Under the best SFE conditions tested for diterpenoids, which involved extraction at 60°C and 100 bar, the extractive efficiencies were 132 and 22 µg/g for AP and neoandrographolide, respectively. The modifier percentage significantly affected the extraction efficiency. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Simultaneous quantification of major flavonoids in "Bawanghua", the edible flower of Hylocereus undatus using pressurised liquid extraction and high performance liquid chromatography.

    Science.gov (United States)

    Yi, Yan; Zhang, Qing-Wen; Li, Song-Lin; Wang, Ying; Ye, Wen-Cai; Zhao, Jing; Wang, Yi-Tao

    2012-11-15

    A pressurised liquid extraction (PLE) and high performance liquid chromatography (HPLC) method was developed for simultaneous quantification of six major flavonoids in edible flower of Hylocereus undatus. In order to achieve the baseline separation of two pairs of isomers, the HPLC conditions were optimised with different kind of reversed phase columns and mobile phase gradient programs. In addition, the solvent concentration, extraction temperature, extraction time and flush cycle for PLE were also optimised. Zorbax SB-C8 (100×2.1 mm, 1.8 μm) column was chosen with acetonitrile and water containing 0.1% trifluoroacetic acid as mobile phase, the six analytes were eluted with baseline separation. The calibration curves showed good linearity (r(2)>0.9994) with LODs and LOQs less than 0.90 and 3.60 ng respectively. The RSDs for intra- and inter-day repeatability was not more than 1.09% and 1.79% respectively. The overall recovery of the assay was 96.9-105.2%. The sample was stable for at least 12 h. The newly established method was successfully applied to quantify six flavonoids in different parts of "Bawanghua", and the commercial samples from different locations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Silica-based monolithic capillary columns modified by liposomes for characterization of analyte–liposome interactions by capillary liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Moravcová, Dana; Planeta, Josef; Wiedmer, S. K.

    2013-01-01

    Roč. 1317, SI (2013), s. 159-166 ISSN 0021-9673 R&D Projects: GA MV VG20112015021; GA ČR(CZ) GAP206/11/0138 Institutional support: RVO:68081715 Keywords : monolithic silica capillary column * immobilized liposomes * biomimicking stationary phase Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.258, year: 2013

  1. Characterization of polymer-based monolithic capillary columns by inverse size-exclusion chromatography and mercury-intrusion porosimetry

    NARCIS (Netherlands)

    Urban, J.; Eeltink, S.; Jandera, P.; Schoenmakers, P.J.

    2008-01-01

    Organic-polymer monolithic capillary columns were prepared in fused-silica capillaries by a radical copolymerization reaction of butyl methacrylate and ethylene dimethacrylate monomers in the presence of 1,4-butanediol and 1-propanol as porogen solvents and azobisisobutyronitrile as the initiator.

  2. Extractive alkylation of 6-mercaptopurine and determination in plasma by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Floberg, S; Hartvig, P; Lindström, B; Lönner-Holm, G; Odlind, B

    1981-09-11

    An analytical procedure was developed for the determination of 6-mercaptopurine in plasma. Owing to the polar character and low plasma concentration of the compound, extraction and derivatization was carried out directly from the plasma sample by extractive alkylation. Determination was made using gas chromatography-mass spectrometry with multiple-ion detection. Conditions with respect to the rate of formation and the stability of the derivative formed in the extractive alkylation step were evaluated. The selectively of the method to azathioprine and to metabolites was thoroughly investigated. No 6-mercaptopurine was formed from azathioprine added to water or plasma and run through the method. The method enables the detection of 2 ng of 6 mercaptopurine in a 1.0-ml plasma sample. Quantitative determinations were done down to 10 ng/ml 6 mercaptopurine in plasma.

  3. Analysis of lignans in Magnoliae Flos by turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai

    2016-04-01

    In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Phenolic composition of pomegranate peel extracts using an LC-MS approach with silica hydride columns

    Science.gov (United States)

    The peels of different pomegranate cultivars (Molla Nepes, Parfianka, Purple Heart, Wonderful and Vkunsyi) were compared in terms of phenolic composition and total phenolics. Analyses were performed on two silica hydride-based stationary phases: phenyl and undecenoic acid columns. Quantitation was ...

  5. Monolithic columns based on a poly(styrene-divinylbenzene-methacrylic acid) copolymer for capillary liquid chromatography of small organic molecules

    Czech Academy of Sciences Publication Activity Database

    Svobodová, A.; Křížek, T.; Širc, Jakub; Šálek, Petr; Tesařová, E.; Coufal, P.; Štulík, K.

    2011-01-01

    Roč. 1218, č. 11 (2011), s. 1544-1547 ISSN 0021-9673 R&D Projects: GA AV ČR KAN200520804 Institutional research plan: CEZ:AV0Z40500505 Keywords : capillary liquid chromatography * methacrylic acid * polystyrene-based monolithic stationary phase Subject RIV: EI - Biotechnology ; Bionics Impact factor: 4.531, year: 2011

  6. A new co conversion technology based on liquid/liquid extraction column

    Energy Technology Data Exchange (ETDEWEB)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Brackx, Emmanuelle [CEA Valrho - Marcoule - BP 17171 - 30207 Bagnols sur Ceze Cedex (France)

    2009-06-15

    The current objective of implementing 'direct' coprecipitation of uranium, plutonium and minor actinides for nuclear fuel re-fabrication leads to reconsider the (co)precipitation step, and more precisely its adaptability to new flowrates' specifications. Indeed, coprecipitation of a uranium fraction together with plutonium results in an appreciable increase in the process flow rates for this step. The technological impact of the increase in capacity could require the development of a different concept for a continuous device capable of ensuring the proposed process. A new type of device designed and patented by the CEA has been tested since 2007. The patent is for organic confinement in a pulsed column (PC) or Couette column (CC). The precipitation reaction between the oxalate complexing agent and a surrogate nitrate-cerium(II) or neodymium(III) alone, or coprecipitated uranium(IV) and cerium(III), occurs within an emulsion created in the device by these two phases flowing with a counter-current chemically inert organic phase (for example TPH) produced by the stirring action of the pulsator (PC) or the central rotor (CC). The precipitate is confined and thus does not form deposits on the vessel walls (which are also water-repellent); it flows downward by gravity and exits the column continuously into a settling tank. This paper describes the recent results obtained with this new technology for precipitation of Ce and Nd and coprecipitation of U + Ce in pulsed column and Couette column. It describes a first modeling allowing further extrapolation of this device to high capacities. (authors)

  7. New and highly efficient column chromatographic extraction and simple purification of camptothecin from Camptotheca acuminata and Nothapodytes pittosporoides.

    Science.gov (United States)

    Zeng, Xue-Hua; Li, Yue-Hong; Wu, Shan-Shan; Hao, Rui-Lin; Li, Hui; Ni, He; Han, Han-Bing; Li, Hai-Hang

    2013-01-01

    Camptothecin, a widely used natural anti-cancer drug, is difficult to extract and purify effectively from plants. To develop new and highly efficient extraction and purification methods for analysis and production of camptothecin from leaves and fruits of Camptotheca acuminata and Nothapodytes pittosporoides roots. Dried materials were loaded in empty columns with fivefold 60% ethanol for leaves or 70% ethanol for fruits of C. acumnata, and sixfold 70% ethanol for N. pittosporoides roots. The columns were eluted with the same solvents at room temperature. Eluent was collected as extraction solution. Extraction solution from leaves and fruits of C. acuminata was vacuum-evaporated to remove ethanol, precipitated at pH 8.0 to remove alkaline insolubles and fractionated with chloroform at pH 3.0, which yields a crude product with 70% purity. Extraction solution from N. pittosporoides roots was concentrated to 1/10 volume and precipitated at pH 3.0, which yields a crude product with 60% purity. All crude products were purified by crystallisation. All steps were monitored by HPLC. Camptothecin was extracted from the three plant materials at a 98% rate with 15- or 18-fold solvent for content analysis, or at a 97% rate with five- or sixfold solvent for production. All crude products were purified to 98%. The overall recovery rates of camptothecin from plant materials to purified products reached 92% or higher. The new procedures are simple and highly efficient, and have multiple advantages for quantitative analysis and large production of camptothecin from plants. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Determination of natural colorants in plant extracts by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    RENETA GEVRENOVA

    2010-07-01

    Full Text Available The determination of the colouring compounds apigenin (1, lawsone (2, juglone (3 and indigotin (4 in plant extracts using HPLC–UV/Vis methods is reported. The methods were applied to the analysis of 1–4 in ethanolic and propylene glycolic extracts originating, respectively, from chamomile (Chamomilla recutita [L] Rauschert, Asteraceae, henna (Lawsonia inermis L., Lythraceae, walnut (Juglans regia L., Juglandaceae and natural indigo (Indigofera sp., Fabaceae. In the case of the indigo extracts, an optimized acid hydrolysis was applied. HPLC separations were performed on a Hypersil ODS RP18 column using linear gradient elution programs. The detection limits for 1–4 were 0.11, 0.6, 0.10, 0.089 μg mL-1, respectively. The procedure did not involve any sample “clean-up” methods. The amounts of the colouring compounds ranged from 0.006 (3 to 0.13 mg mL-1 (4 in the ethanolic extracts and from 0.22 (2 to 1.44 mg mL-1 (4 in propylene glycolic extracts. The proposed HPLC methods are advantageous in terms of sample preparation and the selective separation of the compounds. The plant dye extracts are commonly used in hair colouring formulations. The results indicate that the methods developed may serve for the quantitative control of dying plants and cosmetic products.

  9. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  10. Immunoaffinity chromatography for the sample pretreatment of Taxus plant and cell extracts prior to analysis of taxanes by high-performance liquid chromatography

    NARCIS (Netherlands)

    Theodoridis, G; Haasnoot, W; Schilt, R; Jaziri, M; Diallo, B; Papadoyannis, IN; de Jong, GJ; Cazemier, G.

    2002-01-01

    The application of immunoaffinity chromatography for the purification of Taxus plant and cell extracts prior to the HPLC analysis is described. Polyclonal antibodies raised against 10-deacetylbaccatin III (10-DAB III), paclitaxel's main precursor in plant, were characterised by enzymed-linked

  11. Fast comprehensive two-dimensional gas chromatography method for fatty acid methyl ester separation and quantification using dual ionic liquid columns.

    Science.gov (United States)

    Nosheen, Asia; Mitrevski, Blagoj; Bano, Asghari; Marriott, Philip J

    2013-10-18

    Safflower oil is a complex mixture of C18 saturated and unsaturated fatty acids amongst other fatty acids, and achieving separation between these similar structure components using one dimensional gas chromatography (GC) may be difficult. This investigation aims to obtain improved separation of fatty acid methyl esters in safflower oil, and their quantification using comprehensive two-dimensional GC (GC×GC). Here, GC×GC separation is accomplished by the coupling of two ionic liquid (IL) column phases: the combination of SLB-IL111 with IL59 column phases was finally selected since it provided excellent separation of a FAME standard mixture, as well as fatty acids in safflower and linseed oil, compared to other tested column sets. Safflower oil FAME were well separated in a short run of 16min. FAME validation was demonstrated by method reproducibility, linearity over a range up to 500mgL(-1), and limits of detection which ranged from 1.9mgL(-1) to 5.2mgL(-1) at a split ratio of 20:1. Quantification was carried out using two dilution levels of 200-fold for major components and 20-fold for trace components. The fatty acids C15:0 and C17:0 were not reported previously in safflower oil. The SLB-IL111/IL59 column set proved to be an effective and novel configuration for separation and quantification of vegetable and animal oil fatty acids. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Acylhydrazone bond dynamic covalent polymer gel monolithic column online coupling to high-performance liquid chromatography for analysis of sulfonamides and fluorescent whitening agents in food.

    Science.gov (United States)

    Zhang, Chengjiang; Luo, Xialin; Wei, Tianfu; Hu, Yufei; Li, Gongke; Zhang, Zhuomin

    2017-10-13

    A new dynamic covalent polymer (DCP) gel was well designed and constructed based on imine chemistry. Polycondensation of 4,4'-biphenyldicarboxaldehyde and 1,3,5-benzenetricarbohydrazide via Schiff-base reaction resulted in an acylhydrazone bond gel (AB-gel) DCP. AB-gel DCP had three-dimensional network of interconnected nanoparticles with hierarchically porous structure. AB-gel DCP was successfully fabricated as a monolithic column by an in-situ chemical bonding method for online enrichment and separation purpose with excellent permeability. AB-gel DCP based monolithic column showed remarkable adsorption affinity towards target analytes including sulfonamides (SAs) and fluorescent whitening agents (FWAs) due to its strong π-π affinity, hydrophobic effect and hydrogen bonding interaction. Then, AB-gel DCP based monolithic column was applied for online separation and analysis of trace SAs and FWAs in food samples coupled with high-performance liquid chromatography (HPLC). Sulfathiazole (ST) and sulfadimidine (SM2) in one positive weever sample were actually found and determined with concentrations of 273.8 and 286.3μg/kg, respectively. 2,5-Bis(5-tert-butyl-2-benzoxazolyl) thiophene (FWA184) was actually quantified in one tea infusion sample with the concentration of 268.5ng/L. The spiked experiments suggested the good recoveries in range of 74.5-110% for SAs in weever and shrimp samples with relative standard deviations (RSDs) less than 9.7% and in range of 74.0-113% for FWAs in milk and tea infusion samples with RSDs less than 9.0%. AB-gel DCP monolithic column was proved to be a promising sample preparation medium for online separation and analysis of trace analytes in food samples with complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Combined solid-phase extraction and gas chromatography-mass spectrometry used for determination of chloropropanols in water.

    Science.gov (United States)

    González, Paula; Racamonde, Inés; Carro, Antonia M; Lorenzo, Rosa A

    2011-10-01

    A sensitive and rapid derivatization method for the simultaneous determination of 1,3-dichloro-2-propanol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in water samples has been developed. The aim was to research the optimal conditions of the derivatization process for two selected reagents. A central composite design was used to determine the influence of derivatization time, derivatization temperature and reagent volume. A global desirability function was applied for multi-response optimization. The analysis was performed by gas chromatography-mass spectrometry. During the optimization of the extraction procedure, four different types of solid-phase extraction (SPE) columns were tested. It was demonstrated that the Oasis HLB cartridge produced the best recoveries of the target analytes. The pH value and the salinity were investigated using a Doehlert design. The best results for the SPE of both analytes were obtained with 1.5 g of NaCl and pH 6. The proposed method provides high sensitivity, good linearity (R(2)≥0.999) and repeatability (relative standard deviations % between 2.9 and 3.4%). Limits of detection and quantification were in the range of 1.4-11.2 ng/mL and 4.8-34.5 ng/mL, respectively. Recoveries obtained for water samples were ca. 100% for 1,3-DCP and 3-MCPD. The method has been successfully applied to the analysis of different samples including commercially bottled water, an influent and effluent sewage. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Programmed temperature vaporizing injector to filter off disturbing high boiling and involatile material for on-line high performance liquid chromatography gas chromatography with on-column transfer.

    Science.gov (United States)

    Biedermann, Maurus; Grob, Koni

    2013-03-15

    Insertion of a programmed temperature vaporizing (PTV) injector under conditions of concurrent solvent recondensation (CSR) into the on-line HPLC-GC interface for on-column transfer (such as the retention gap technique with partially concurrent eluent evaporation) enables filtering off high boiling or involatile sample constituents by a desorption temperature adjusted to the required cut-off. Details of this technique were investigated and optimized. Memory effects, observed when transferred liquid was sucked backwards between the transfer line and the wall of the injector liner, can be kept low by a small purge flow rate through the transfer line at the end of the transfer and the release of the liquid through a narrow bore capillary kept away from the liner wall. The column entrance should be within the well heated zone of the injector to prevent losses of solute material retained on the liner wall during the splitless period. The desorption temperature must be maintained until an elevated oven temperature is reached to prevent peak broadening resulting of a cool inlet section in the bottom part of the injector. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. High-resolution ultrahigh-pressure long column reversed-phase liquid chromatography for top-down proteomics

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Yufeng; Tolic, Nikola; Piehowski, Paul D.; Shukla, Anil K.; Kim, Sangtae; Zhao, Rui; Qu, Yi; Robinson, E. W.; Smith, Richard D.; Pasa-Tolic, Ljiljana

    2017-05-01

    We report development of an approach providing high-resolution RPLC of proteins and its utility for mass spectrometry-based top-down proteomics. A chromatographic peak capacity of ~450 was achieved for proteins and large polypeptides having MWs up to 43 kDa in the context of proteomics applications. RPLC column lengths from 20 to 200 cm, particle sizes from 1.5 to 5 m, bonding alkyl chains from C1 to C2, C4, C8, and C18, and particle surface structures that spanned porous, superficially porous (porous shell, core-shell), and nonporous were investigated at pressures up to14K psi. Column length was found as the most important factor for >20 kDa proteins in gradient RPLC, and shortening column length degraded RPLC resolution and sensitivity regardless of the size and surface structure of the packing particles used. The alkyl chains bonded to the silica particle surface significantly affected the RPLC recovery and efficiency, and short alkyl C1-C4 phases provided higher sensitivity and resolution than C8 and C18 phases. Long gradient separations (e.g., >10 hours) with long columns (e.g., 100 cm) were particularly effective in conjunction with use of high accuracy mass spectrometers (e.g., the Orbitrap Elite) for top-down proteomics with improved proteoform coverage by allowing multiple HCD, CID, and ETD dissociation modes. It was also found that HCD produced small fragments useful for proteoform identification, while low energy CID and ETD often complemented HCD by providing large fragments.

  16. A new oxalate co-conversion technology based on liquid/liquid extraction columns

    International Nuclear Information System (INIS)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Allegri, Patrick

    2008-01-01

    The current objective of fabricating non proliferating nuclear fuel by 'direct' coprecipitation of uranium, plutonium and minor actinides requires a new process to replace the (co)precipitation step. The technological impact of an increased capacity on the work zone could require the development of a different concept for a continuous device capable of ensuring the proposed goal. A new type of device designed and patented by the Cea was tested in 2007. The patent is for organic confinement in a pulsed column. First, precipitation of cerium or neodymium alone has been carried out in this device, with satisfactory results. Moreover, a recent test campaign demonstrated that a uranium-cerium co-precipitate easily forms when the two nitrates are mixed in a pulsed column of the same size operating under very similar process conditions. Qualitatively, the co-precipitate meets the process requirements. (authors)

  17. A new oxalate co-conversion technology based on liquid/liquid extraction columns

    Energy Technology Data Exchange (ETDEWEB)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Allegri, Patrick [CEA Nuclear Energy Division - Fuel Cycle Technology Division - System and Chemical Engineering Device Marcoule - 30207 Bagnols sur Ceze (France)

    2008-07-01

    The current objective of fabricating non proliferating nuclear fuel by 'direct' coprecipitation of uranium, plutonium and minor actinides requires a new process to replace the (co)precipitation step. The technological impact of an increased capacity on the work zone could require the development of a different concept for a continuous device capable of ensuring the proposed goal. A new type of device designed and patented by the Cea was tested in 2007. The patent is for organic confinement in a pulsed column. First, precipitation of cerium or neodymium alone has been carried out in this device, with satisfactory results. Moreover, a recent test campaign demonstrated that a uranium-cerium co-precipitate easily forms when the two nitrates are mixed in a pulsed column of the same size operating under very similar process conditions. Qualitatively, the co-precipitate meets the process requirements. (authors)

  18. Determination of nitrate in lettuce by ion chromatography after microwave water extraction

    Directory of Open Access Journals (Sweden)

    Humberto Brevilato Novaes

    2009-01-01

    Full Text Available Lettuce is worldwide known as the most important vegetable. In this context, most farmers are searching new techniques for best quality products including hydropony. However, nitrate is of great concern, since it has a negative impact on human metabolism. The main objective of the present work was to evaluate the nitrate content of lettuce produced by conventional and hydroponic systems. The determination was conducted by ion chromatography and a new method of extraction was tested using microwave oven digestion. The results indicated that nitrate level produced in the conventional system was lower than in the hydroponic system.

  19. Determination of 90SR in food using extraction chromatography and LSC - Liquid Scintillation Counting

    International Nuclear Information System (INIS)

    Temba, Eliane S.C.; Amaral, Angela M.; Reis Junior, Aluisio S.; Monteiro, Roberto P.G.

    2013-01-01

    A methodology for the determination of 90 Sr in food is described. The procedure involved a preliminary freeze-drying of the samples followed by dry-ashing and sample digestion. The separation procedure was carried out using extraction chromatography with Sr Resin, from Eichrom, and 90 Sr was measured by liquid scintillation counting (LSC). A certified reference material, IAEA-375, was analyzed in order to evaluate the reliability of the method, and the results showed good agreement between the measured and certified values. The chemical yield was above 90% and the typical counting efficiency was 82%. The calculated limit of detection was 4.8 x 10 -3 Bq g -1 . (author)

  20. Separation of alkali and alkaline earth metals by polyethers using extraction chromatography

    International Nuclear Information System (INIS)

    Smulek, W.; Lada, W.A.

    1979-01-01

    The separation of alkali and alkaline earth metals by means of an acyclic polyether, 1,13-bis(8-chinolinyl)-1, 4, 7, 10, 13-pentaoxatridecane (CPOD), and cyclic polyethers, benzo-15-crown-5 (BC), dibenzo-18-crown-6 (DBC) and dicyclohexyl-18-crown-6 (DCHC), using extraction chromatography has been studied. The alkali metals can be effectively separated using SCN - as the accompanying ion. For alkaline earth metals, the best results were obtained with ClO 4 - ions. Different elution sequences for these groups were observed using chloroform and/meen=/ sitylene as diluents for the polyethers. (author)

  1. Cleanup and analysis of sugar phosphates in biological extracts by using solid phase extraction and anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Smith, Hans Peter; Cohen, A.; Buttler, T.

    1998-01-01

    of Saccharomyces cerevisiae obtained by using cold methanol as quenching agent and chloroform as extraction solvent. It was shown that pretreatment of the cell extract with SPE markedly improved the quality of the liquid chromatography analysis with recoveries of the sugar phosphates close to 100%. Furthermore...

  2. Stationary phases for superheated water chromatography

    International Nuclear Information System (INIS)

    Saha, Shikha

    2002-01-01

    This project focused on the comparison of conventional liquid chromatography and superheated water chromatography. It examined the differences in efficiency and retention of a range of different stationary phases. Alkyl aryl ketones and eight aromatic compounds were separated on PBD-zirconia, Xterra RP 18, Luna C 18 (2) and Oasis HLB columns using conventional LC and superheated water chromatography system. The retention indices were determined in the different eluents. On changing the organic component of the eluent from methanol to acetonitrile to superheated water considerable improvements were found in the peak shapes and column efficiencies on the PBD-zirconia and Oasis HLB columns. PS-DVB, PBD-zirconia and Xterra RP 18 columns have been used in efficiency studies. It was found that simply elevating the column temperature did not increase the efficiency of a separation in superheated water chromatography. The efficiency depended on flow rate, injection volume and also mobile phase preheating system. Although high efficiencies were not achieved with superheated water on PS-DVB and Xterra RP 18 columns, a higher efficiency was achieved on a PBD-zirconia column with superheated water than with 25-35% ACN at room temperature. The proposed theoretical increases in u opt were measured on three columns using superheated water as the mobile phase. The application of the superheated water chromatographic method to the separation of the pungent constituents of ginger by superheated water chromatography-NMR coupling system was studied. The coupling of superheated water chromatography using deuterium oxide to NMR spectroscopy for the separation of dry ginger extract was successful, although the NMR sensitivity in on-line mode coupling system was low. However, four compounds were identified in the ginger extract by stop-flow mode on superheated water chromatography-UV-NMR detection system. (author)

  3. Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography

    Directory of Open Access Journals (Sweden)

    Mallaiah Mekala

    2018-06-01

    Full Text Available The composition of multicomponent determination by colorimetric titration is difficult. This complexity is easily overcome by using Gas Chromatography technique instead of wet method for multi-component mixture analysis. In Gas Chromatography, first the standard chart is prepared by using the known amount sample concentration as the reference. Once calibration chart is prepared the unknown sample concentration easily measured by using the standard chart. In the present study a standard calibration chart developed for the four component system of acetic acid–methanol–methyl acetate–water. The samples were taken at various concentrations of all components and different chromatograms obtained under various concentrations respectively. The method of optimization was first carried out to get the sharp peaks of individual components and binary pairs also. By using those conditions, the multi components concentrations were estimated. From the present results, the area under gas chromatogram is linearly varying with mole% of the components compared to mass%. Keywords: Gas Chromatography, Esterification, Calibration, Retention time, Optimization

  4. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Moderate-Use Pesticides and Selected Degradates in Water by C-18 Solid-Phase Extraction and Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Sandstrom, Mark W.; Stroppel, Max E.; Foreman, William T.; Schroeder, Michael P.

    2001-01-01

    A method for the isolation and analysis of 21 parent pesticides and 20 pesticide degradates in natural-water samples is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase-extraction columns that contain octadecyl-bonded porous silica to extract the analytes. The columns are dried by using nitrogen gas, and adsorbed analytes are eluted with ethyl acetate. Extracted analytes are determined by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 2 micrograms per liter (?g/L) for most analytes. Single-operator method detection limits in reagent-water samples range from 0.00 1 to 0.057 ?g/L. Validation data also are presented for 14 parent pesticides and 20 degradates that were determined to have greater bias or variability, or shorter holding times than the other compounds. The estimated maximum holding time for analytes in pesticide-grade water before extraction was 4 days. The estimated maximum holding time for analytes after extraction on the dry solid-phase-extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time. The method complements existing U.S. Geological Survey Method O-1126-95 (NWQL Schedules 2001 and 2010) by using identical sample preparation and comparable instrument analytical conditions so that sample extracts can be analyzed by either method to expand the range of analytes determined from one water sample.

  5. Separation and concentration of uranium by extraction chromatography : U(VI) - H3PO4 system

    International Nuclear Information System (INIS)

    Nobre, J.S.M.

    1981-01-01

    The feasibility of using the extraction chromatographic technique as a way to recover uranium from phosphatic rocks evaluated. The behaviour of uranium from raw phsophoric acid solutions in chromatographic systems using the mixture di(2-ethylhexyl) orthophosphoric acid (D2EHPA) - tributyl phosphate (TBP) as the stationary phase was studied. Materials as alumina, activated carbon and the macroporous resins XAD-4 and XAD-7 were used as supports for organic stationary phase. The best results were obtained with poliacrilic polymer XAD-7, due to its excellent chromatographic properties and efficient organic phase retention. Uranium was quantitatively retained by D2EHPA-TBP-XAD-7 columns from synthetic phosphoric acid solutions with typical composition of phosphatic acid liquors. The elution of uranium from this system was also studied, and the best results were obtained with phosphoric acid solutions. This chromatographic column presented a high stability, not changing their properties even after more than twenty cycles, including the conditioning, sorption, wasking and elution steps. Uranium determinations were perfpormed by indirect titration with potassium dichromate and by molecular absorption spectrophotometry with hydrogen peroxide- carbonate. A new and more sensitive method for uranium determination in phosphoric medium, which might be applied to acid liquors of phosphatic ores, was developed. An extraction-photometric method was used, with Arsenazo III (1,8-dihydroxynaphtalene-3,6-disulphonic acid-2,7-bis(azo-2)-phenylarsonic acid) as the reagent for uranium. (Author) [pt

  6. Method Development for Extraction of Butyrylcholin- esterase using Protein-G Agarose Spin Columns

    Directory of Open Access Journals (Sweden)

    Amruta S. Indapurkar

    2015-01-01

    Full Text Available Butyrylcholinesterase (BuChE is a biomarker of organophosphate (OP poisoning and can be used as a diagnostic marker to measure exposure to OP compounds. The purpose of this study was to develop a method to extract BuChE from human plasma. BuChE was extracted from plasma using the NAb protein-G Agarose Spin Kit. Factors affecting extraction like incubation time, plasma volume and cross-linking of antibodies to agarose beads were evaluated. All samples were analyzed for BuChE activity using the Ellman’s assay. The incubation times of plasma and anti-BuChE antibodies marginally affected the extraction efficiency of BuChE whereas a decrease in plasma volume increased the extraction efficiency. Cross-linking of anti-BuChE antibodies on agarose increased the extraction efficiency. The NAb protein-G Spin Kit can be used successfully to extract BuChE from human plasma. This extraction technique may be coupled to downstream analytical analyses for diagnosing exposure to OP compounds.

  7. Spectrophotometric determination of uranium by previous extraction chromatography separation in polimetalic mineral, phosphorites and technological licours

    International Nuclear Information System (INIS)

    Moreno Bermudez, J.; Cabrera Quevedo, C.; Alfonso Mendez, L.; Rodriguez Aguilera, M.

    1994-01-01

    The development of an analytical procedure for spectrophotometric determination of uranium in polimetalic mineral, phosphorites and technological licours is described. The method is based on the previous separation of interfering elements by extraction chromatography and on spectrophotometric determination of uranium (IV) with arsenazo III in concentrated hydrochloric acid. Tributyl phosphate impregnate on politetrafluoroethylene is used as stationary phase and 5.5 M nitric acid is used as movie phase. The influence of matrix-component elements was studies. The development procedure was applied to real samples, being the results compared with those obtained by other well established analytical methods like gamma-spectrometry, laser fluorimetric, spectrophotometry previous uranium separation by liquid liquid extraction and anion exchange. The reproducibility is evaluated and the detection limited has been established for each studied matrix. A procedure for correcting the thorium interference has been developed for samples with a Th/ 3U8O higher than 0.2

  8. The removal of uranium from acidic media using ion exchange and/or extraction chromatography

    International Nuclear Information System (INIS)

    FitzPatrick, J.R.; Schake, B.S.; Murphy, J.; Holmes, K.; West, M.H.

    1996-06-01

    The separation and purification of uranium from either nitric acid or hydrochloric acid media can be accomplished by using either solvent extraction or ion-exchange. Over the past two years at Los Alamos, emerging programs are focused on recapturing the expertise required to do limited, small-quantity processing of enriched uranium. During this period of time, we have been investigating ion-addition, waste stream polishing is associated with this effort in order to achieve more complete removal of uranium prior to recycle of the acid. Extraction chromatography has been demonstrated to further polish the uranium from both nitric and hydrochloric acid media thus allowing for a more complete recovery of the actinide material and creation of less waste during the processing steps

  9. Alternative extraction of alkaloid anticarcinogens from Brazilian "vinca rosea" using Ion exchange chromatography

    Directory of Open Access Journals (Sweden)

    Sérgio Freire de Carvalhaes

    Full Text Available Extracts in ethanol and ethanol-ammonia of dried leaves from Catharanthus roseus, gathered at Rio de Janeiro state, were adsorbed in a strongly acidic cation exchange resin with sulfonic acid group, using the finite bath method, resulting in an alkaloid retained fraction and an acidic and neutral unretained fraction. High Performance Liquid Chromatography showed the isolation of the alkaloid fraction to be highly selective and with good performance, with an absence of alkaloids in the unretained fraction, while the retained fraction presented 1,54-6,35 mg/g of vindoline and 0,12-0,91 mg/g of vinblastine, common for an alkaloid-rich concentrate, usually obtained by classic extraction with several steps using solvents.

  10. Plasma L-ergothioneine measurement by high-performance liquid chromatography and capillary electrophoresis after a pre-column derivatization with 5-iodoacetamidofluorescein (5-IAF) and fluorescence detection.

    Science.gov (United States)

    Sotgia, Salvatore; Pisanu, Elisabetta; Pintus, Gianfranco; Erre, Gian Luca; Pinna, Gerard Aime; Deiana, Luca; Carru, Ciriaco; Zinellu, Angelo

    2013-01-01

    Two sensitive and reproducible capillary electrophoresis and high-performance liquid chromatography-fluorescence procedures were established for quantitative determination of L-egothioneine in plasma. After derivatization of L-ergothioneine with 5-iodoacetamidofluorescein, the separation was carried out by HPLC on an ODS-2 C-18 sperisorb column by using a linear gradient elution and by HPCE on an uncoated fused silica capillary, 50 µm id, and 60 cm length. The methods were validated and found to be linear in the range of 0.3 to 10 µmol/l. The limit of quantification was 0.27 µmol/l for HPCE and 0.15 µmol/l for HPLC. The variations for intra- and inter-assay precision were around 6 RSD%, and the mean recovery accuracy close to 100% (96.11%).

  11. Serum vitamin A and vitamin E in Japanese black fattening cattle in Miyazaki prefecture as determined by automatic column-switching high performance liquid chromatography.

    Science.gov (United States)

    Adachi, K; Katsura, N; Nomura, Y; Arikawa, A; Hidaka, M; Onimaru, T

    1996-05-01

    Japanese Black fattening cattle in Miyazaki prefecture, Japan were examined for serum vitamin A (V. A) and vitamin E (V. E) by automatic column-switching high performance liquid chromatography with automated deproteinization. Results indicated that most Japanese Black fattening cattle in Miyazaki prefecture may be provided with V. A supplement and diets including little V. E, moderate beta-carotene and V. A during the early fattening stage, and diets including little beta-carotene, V. A and V. E during the middle and later fattening stages. Therefore, monitoring serum V. A and V. E in Japanese Black fattening cattle throughout the fattening period seems necessary for farmers in Miyazaki prefecture to avoid economic loss attributable to these deficiencies.

  12. Speciation analysis of mercury in sediments, zoobenthos and river water samples by high-performance liquid chromatography hyphenated to atomic fluorescence spectrometry following preconcentration by solid phase extraction

    International Nuclear Information System (INIS)

    Margetinova, Jana; Houserova-Pelcova, Pavlina; Kuban, Vlastimil

    2008-01-01

    A high-pressure microwave digestion was applied for microwave-assisted extraction (MAE) of mercury species from sediments and zoobenthos samples. A mixture containing 3 mol L -1 HCl, 50% aqueous methanol and 0.2 mol L -1 citric acid (for masking co-extracted Fe 3+ ) was selected as the most suitable extraction agent. The efficiency of proposed extraction method was better than 95% with R.S.D. below 6%. A preconcentration method utilizing a 'homemade' C18 solid phase extraction (SPE) microcolumns was developed to enhance sensitivity of the mercury species determination using on-column complex formation of mercury-2-mercaptophenol complexes. Methanol was chosen for counter-current elution of the retained mercury complexes achieving a preconcentration factor as much as 1000. The preconcentration method was applied for the speciation analysis of mercury in river water samples. The high-performance liquid chromatography-cold vapour atomic fluorescence spectrometric (HPLC/CV-AFS) method was used for the speciation analysis of mercury. The complete separation of four mercury species was achieved by an isocratic elution of aqueous methanol (65%/35%) on a Zorbax SB-C18 column (4.6 mm x 150 mm, 5 μm) using the same complexation reagent (2-mercaptophenol). The limits of detection were 4.3 μg L -1 for methylmercury (MeHg + ), 1.4 μg L -1 for ethylmercury (EtHg + ), 0.8 μg L -1 for inorganic mercury (Hg 2+ ), 0.8 μg L -1 for phenylmercury (PhHg + )

  13. Post-column mobile phase adjustment: a strategy to eliminate the contradiction between liquid chromatography and mass spectrometry in the determination of flavonoids in rat plasma.

    Science.gov (United States)

    Zheng, Shirui; Ma, Zhiyuan; Han, Haixia; Ye, Jianfeng; Wang, Ruwei; Cai, Sheng; Zhou, Hui; Yu, Lushan; Zeng, Su; Jiang, Huidi

    2014-07-01

    Flavonoids are a group of important naturally occurring polyphenolic compounds with a wide range of biological effects. In this study, a sensitive liquid chromatography tandem mass spectrometry method was developed to simultaneously determine multiple active flavonoids, including quercetin (Que), kaempferol (Kae), apigenin (Api), isorhamnetin (Iso), luteolin (Lut), and naringenin (Nar), in rat plasma. To achieve a satisfied peak shape and LC separation, formic acid with the concentration between 0.05 and 0.2%, or in some case 5%, was generally used to acidify the LC mobile phase in reported studies. Here we found that even 0.05% formic acid could lead to strong mass signal suppression, and the absence of formic acid could reverse the signal suppression but cause serious peak tailing. There is an irreconcilable contradiction between liquid chromatography (LC) and mass spectrometry (MS). In order to simultaneously satisfy LC and MS, LC mobile phase with 0.00075% formic acid and post column mobile phase adjustment with 0.0677% ammonium solution in isopropanol were applied. Compared with the conventional method with mobile phase containing 0.05% formic acid, the mass signal response of Que, Kae, Api, Iso, Lut, Nar, and Oka increased 26.2, 18.6, 13.6, 23.5, 17.5, 15.6 and 15.4 fold, respectively. In addition, the post column mobile phase addition exhibited the better peak shape for the reduction of analytes longitudinal diffusion. The method has been fully validated according to FDA guidelines within the linear range between 0.328 ng mL⁻¹ and 168 ng mL⁻¹, and successfully applied to a pilot pharmacokinetic study of rats after administering 5.43 g kg⁻¹ Pollen of Brassica campestris. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent.

    Science.gov (United States)

    Ohta, Kazutoku; Ohashi, Masayoshi; Jin, Ji-Ye; Takeuchi, Toyohide; Fujimoto, Chuzo; Choi, Seong-Ho; Ryoo, Jae-Jeong; Lee, Kwang-Pill

    2003-05-16

    The application of various hydrophilic cation-exchange resins for high-performance liquid chromatography (sulfonated silica gel: TSKgel SP-2SW, carboxylated silica gel: TSKgel CM-2SW, sulfonated polymethacrylate resin: TSKgel SP-5PW, carboxylated polymethacrylate resins: TSKgel CM-5PW and TSKgel OA-Pak A) as stationary phases in ion-exclusion chromatography for C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, butyric, isovaleric, valeric, isocaproic, caproic, 2-methylhexanoic and heptanoic acids) and benzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic, salicylic acids and phenol) was carried out using diluted sulfuric acid as the eluent. Silica-based cation-exchange resins (TSKgel SP-2SW and TSKgel CM-2SW) were very suitable for the ion-exclusion chromatographic separation of these benzenecarboxylic acids. Excellent simultaneous separation of these benzenecarboxylic acids was achieved on a TSKgel SP-2SW column (150 x 6 mm I.D.) in 17 min using a 2.5 mM sulfuric acid at pH 2.4 as the eluent. Polymethacrylate-based cation-exchange resins (TSKgel SP-5PW, TSKgel CM-5PW and TSKgel OA-Pak A) acted as advanced stationary phases for the ion-exclusion chromatographic separation of these C1-C7 aliphatic carboxylic acids. Excellent simultaneous separation of these C1-C7 acids was achieved on a TSKgel CM-5PW column (150 x 6 mm I.D.) in 32 min using a 0.05 mM sulfuric acid at pH 4.0 as the eluent.

  15. Determination of six polyether antibiotic residues in foods of animal origin by solid phase extraction combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ha, Jing; Song, Ge; Ai, Lian-Feng; Li, Jian-Chen

    2016-04-01

    A new method using solid phase extraction (SPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of six polyether antibiotics, including lasalocid, salinomycin, monensin, narasin, madubamycin and nigericin residues, in foods of animal origin. The samples were extracted with acetonitrile and purified by ENVI-Carb SPE columns after comparing the impurity effect and maneuverability of several SPE cartridges. Subsequently, the analytes were separated on a Hypersil Gold column (2.1×150mm, 5μm) and analyzed by MS/MS detection. The limit of quantization (LOQ) for milk and chicken was 0.4μg/kg, and for chicken livers and eggs, it was 1μg/kg. The linearity was satisfactory with a correlation coefficient of >0.9995 at concentrations ranging from 2 to 100μg/L. The average recoveries of the analytes fortified at three levels ranged from 68.2 to 114.3%, and the relative standard deviations ranged from 4.5 to 12.1%. The method was suitable for quantitative analysis and confirmation of polyether antibiotic residues in foods of animal origin. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Comparison of several solid-phase extraction sorbents for continuous determination of amines in water by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurado-Sánchez, Beatriz; Ballesteros, Evaristo; Gallego, Mercedes

    2009-08-15

    A semiautomatic method has been proposed for the determination of different types of amines in water samples including anilines, chloroanilines, N-nitrosamines and aliphatic amines. The analytes were retained on a solid-phase extraction sorbent column and after elution, 1 microL of the extract was analysed by gas chromatography coupled with electron impact ionization mass spectrometry. A systematic overview is given of the advantages and disadvantages of several sorbents (LiChrolut EN, Oasis HLB, RP-C(18), graphitized carbon black, fullerenes and nanotubes) in the retention of amine compounds and based on sensitivity, selectivity and reliability. The retention efficiency for the studied amines was higher (ca. 100%) with LiChrolut EN and Oasis HLB than it was with RP-C(18) and fullerenes (53 and 62%, respectively, on average). Detection limits of 0.5-16 ng L(-1) for the 27 amines studied were obtained when using a sorbent column containing 75 mg of LiChrolut EN for 100mL of sample, the RSD being lower than 6.5%. The method was applied with good accuracy and precision in the determination of amines in various types of water including river, pond, tap, well, drinking, swimming pool and waste.

  17. Cation-selective extraction column study for the conception of nuclear medical radionuclide generators; Untersuchung kationenselektiver Extraktionssaeulen zur Konzeption nuklearmedizinischer Radionuklidgeneratoren

    Energy Technology Data Exchange (ETDEWEB)

    Streng, Roman

    2012-07-09

    The topic of the present work is the conception of a Yttrium-90 radionuclide generator for nuclear medicine applications. Due to its physical properties Yttrium-90 is considered as one of the most useful nuclides for radiotherapeutic cancer treatment. The parent nuclide Strontium-90 is gained during reprocessing of fission products. Thus, the sustained availability of large quantities of Yttrium-90 is limited to a number of research facilities. A radionuclide generator provides an independent Yttrium-90 source and enhances the capacities for radiopharmaceutical research and biomedical applications. The present work focussed on the identification of appropriate column materials for the separation of Strontium and Yttrium. The results for two materials are reported: AnaLig {sup registered} Sr-01 and crystalline antimonic acid. Based on the mode of operation of the Technetium-99m generator the aim was to enable the construction of a compact, enclosed apparatus. The projected device comprises a reservoir for the eluant, the ion-exchange column, pipings and radiation shielding. Elution of Yttrium-90 could then be easily performed by connecting evacuated vials to the outlet tube. The prospected concept involves physical and chemical confinements that exclude most of the known processes for Strontium-Yttrium separation. For example no ligands, no oxidizing reactants (e.g. nitric acid) and no organic solvents are to be used, but small volumes of isotonic or buffer solutions and dilute acids respectively. AnaLig {sup registered} Sr-01 is a commercially available resin used in extraction chromatography. Its high selectivity for Strontium cations results from the strictly defined cavity of the imbedded cryptand. Determination of weight distribution coefficients, elution studies and pre-generator experiments were carried out. Quantitative separation of Yttrium from Strontium and Zirconium is possible using small volumes of 0,05 M hydrochloric acid as eluant. Furthermore, high

  18. A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kolmonen, Marjo [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland) and Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland)]. E-mail: marjo.kolmonen@helsinki.fi; Leinonen, Antti [Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland); Pelander, Anna [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland); Ojanperae, Ilkka [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland)

    2007-02-28

    A general screening method based on solid phase extraction (SPE) and liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) was developed and investigated with 124 different doping agents, including stimulants, {beta}-blockers, narcotics, {beta}{sub 2}-adrenergic agonists, agents with anti-estrogenic activity, diuretics and cannabinoids. Mixed mode cation exchange/C8 cartridges were applied to SPE, and chromatography was based on gradient elution on a C18 column. Ionization of the analytes was achieved with electrospray ionization in the positive mode. Identification by LC/TOFMS was based on retention time, accurate mass and isotopic pattern. Validation of the method consisted of analysis of specificity, analytical recovery, limit of detection and repeatability. The minimum required performance limit (MRPL), established by World Anti-Doping Agency (WADA), was attained to 97 doping agents. The extraction recoveries varied between 33 and 98% and the median was 58%. Mass accuracy was always better than 5 ppm, corresponding to a maximum mass error of 0.7 mDa. The repeatability of the method for spiked urine samples, expressed as median of relative standard deviations (RSD%) at concentrations of MRPL and 10 times MRPL, were 14% and 9%, respectively. The suitability of the LC/TOFMS method for doping control was demonstrated with authentic urine samples.

  19. Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2009-01-01

    This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed...... by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example......, 100−200 g of soil and sediment, 20 g of seaweed, and 200 L of seawater following analyte preconcentration. The investigation of the separation capability of the assembled SI system revealed that up to 200 g of soil or sediment can be treated using a column containing about 0.70 g of TEVA resin...

  20. Analysis and extension of the Furter equation, and its application in the simulation of saline extractive distillation columns

    Directory of Open Access Journals (Sweden)

    Ernesto O. Timmermann

    Full Text Available ABSTRACT Simulation of saline extractive distillation columns is a difficult task owing to the high nonlinearity of the rigorous models that represent these systems. The use of simple models to obtain initial estimates of equilibrium compositions may improve the stability and rate of convergence. One of the simplest models to study the vapor-liquid equilibrium of binary liquid mixtures + salt systems is the Furter equation. This model was analyzed in the present work by means of the incorporation of activity coefficient models in the ratio of relative volatility. This approach allowed systematic extensions of the Furter equation and a brief review of the theoretical basis of the original equation. As a result of these extensions, two simple equations were proposed and tested with experimental data from 20 systems, including binary liquid mixtures + salt systems and binary liquid mixtures + ionic liquid systems. Finally, one of these proposed equations was incorporated into the GKTM software in order to assess the utility of these simple models in the simulation of saline extractive distillation columns. The obtained results showed a significant improvement over the previous algorithm.

  1. Determination of organic peroxides by liquid chromatography with on-line post-column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

    Science.gov (United States)

    Wada, Mitsuhiro; Inoue, Keiyu; Thara, Ayuko; Kishikawa, Naoya; Nakashima, Kenichiro; Kuroda, Naotaka

    2003-02-14

    A HPLC method was developed for the simultaneous determination of organic peroxides and hydrogen peroxide with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Organic peroxides [i.e., benzoyl peroxide (BP), tert.-butyl hydroperoxide (BHP), tert.-butyl perbenzoate (BPB), cumene hydroperoxide (CHP)] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide, which was determined by PO-CL detection. The conditions for UV irradiation and PO-CL detection were optimized by a flow injection analysis (FIA) system. Generation of hydrogen peroxide from peroxides with on-line UV irradiation also was confirmed by the FIA system by incorporating an enzyme column reactor immobilized with catalase. The separation of four organic peroxides and hydrogen peroxide by HPLC was accomplished isocratically on an ODS column within 30 min. The detection limits (signal-to-noise ratio=3) were 1.1 microM for hydrogen peroxide, 6.8 microM for BP, 31.3 microM for BHP, 7.5 microM for BPB and 1.3 microM for CHP. The proposed method was applied to the determination of BP in wheat flour.

  2. Development and Application of Immunoaffinity Chromatography for Coplanar PCBs in Soil and Sediment

    Science.gov (United States)

    An immunoaffinity chromatography (IAC) column was developed as a simple cleanup procedure for preparing environmental samples for analysis of polychlorinated biphenyls (PCBs). Soil and sediment samples were prepared using pressurized liquid extraction (PLE), followed by the IAC c...

  3. A sensitive and selective quantification of catecholamine neurotransmitters in rat microdialysates by pre-column dansyl chloride derivatization using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Nirogi, Ramakrishna; Komarneni, Prashanth; Kandikere, Vishwottam; Boggavarapu, Rajeshkumar; Bhyrapuneni, Gopinadh; Benade, Vijay; Gorentla, Srinivasarao

    2013-01-15

    A rapid and sensitive liquid chromatography tandem mass spectrometry method for simultaneous quantification of catecholamine neurotransmitters in microdialysates was developed. The catecholamine neurotransmitters dopamine (DA) and norepinephrine (NE) were pre-column derivatized with dansyl chloride and analyzed. A gradient elution method was used to separate the analytes from the interferences on an Agilent Poroshell 120 EC-C18 outer porous micro particulate column. The method was robust and sensitive to determine with the lower limit of quantification value of 0.068pmol/mL and 0.059pmol/mL for DA and NE, respectively. It has acceptable precision and accuracy for concentrations over the standard curve range. The method was successfully applied for simultaneous quantitation of DA and NE in the prefrontal cortex (PFC) dialysates of rats obtained from a microdialysis study dosed with vehicle and atomoxetine through intra peritoneal (i.p.) route at a dose of 3mg/kg to monitor the change in extracellular concentrations. Thus, accomplishment of this method would facilitate the neurochemical monitoring for discovery of new chemical entities targeted for the treatment of attention deficit hyperactivity disorder (ADHD). Copyright © 2012. Published by Elsevier B.V.

  4. Studies on the wetting properties of plate surfaces used in pulsed extraction columns

    International Nuclear Information System (INIS)

    Tai Derong; Yang Xin; Wang Xinchang

    1991-01-01

    Many factors influence the hydrodynamic characteristics of pulsed column. Of all the factors the surface effect at liquid-liquid interfaces and liquid-solid boundaries may be the most influential factor to the state of droplets. In order to get some understanding of the behaviour of droplets in a pulsed column, the time history of wetting properties of plates under different conditions in 30% TBP (Kerosene) -HNO 3 -UO 2 (NO 3 ) 2 -H 2 O systems was studied. The results show that the hydrophilic wetting behaviour of the plates changes into the hydrophobic and neutral conditions, respectively after they have been exposed to air and put in the 'open system' within about 50 days after contacting with process solutions. For the case where the access of air is prohibited at the upper organic phase boundary by a well fitting cover, or supersonic pulse cleaning is used to the cartridge, the behaviour of the metal surface stays in the original good hydrophilic wetting condition constant with time. The uranium charged liquid systems can conserve hydrophilic behaviour better than the non-charged systems under identical conditions. It is also found that the interfacial tension is unvaried with time for saturated process systems, hence it has no effects on the variation of wettability

  5. Direct online extraction and determination by supercritical fluid extraction with chromatography and mass spectrometry of targeted carotenoids from red Habanero peppers (Capsicum chinense Jacq.).

    Science.gov (United States)

    Zoccali, Mariosimone; Giuffrida, Daniele; Dugo, Paola; Mondello, Luigi

    2017-10-01

    Recently, supercritical fluid chromatography coupled to mass spectrometry has gained attention as a fast and useful technology applied to the carotenoids analysis. However, no reports are available in the literature on the direct online extraction and determination by supercritical fluid extraction with chromatography and mass spectrometry. The aim of this research was the development of an online method coupling supercritical fluid extraction and supercritical fluid chromatography for a detailed targeted native carotenoids characterization in red habanero peppers. The online nature of the system, compared to offline approaches, improves run-to-run precision, enables the setting of batch-type applications, and reduces the risks of sample contamination. The extraction has been optimized using different temperatures, starting from 40°C up to 80°C. Multiple extractions, until depletion, were performed on the same sample to evaluate the extraction yield. The range of the first extraction yield, carried out at 80°C, which was the best extraction temperature, was 37.4-65.4%, with a %CV range of 2-12. Twenty-one targeted analytes were extracted and identified by the developed methodology in less than 17 min, including free, monoesters, and diesters carotenoids, in a very fast and efficient way. Quantification of the β-carotene was carried out by using the optimized conditions. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Fast analysis of curcuminoids from turmeric (Curcuma longa L.) by high-performance liquid chromatography using a fused-core column.

    Science.gov (United States)

    Osorio-Tobón, J Felipe; Carvalho, Pedro I N; Barbero, Gerardo Fernández; Nogueira, Gislaine Chrystina; Rostagno, Mauricio Ariel; Meireles, Maria Angela de Almeida

    2016-06-01

    The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of a fast method for the analysis of main curcuminoids (curcumin, demethoxycurcumin and bisdemethoxycurcumin) present in extracts of turmeric (Curcuma longa L.). A step-by-step strategy was used to optimize temperature (40-55 °C), flow rate (1.0-2.5 mL min(-1)), mobile phase composition and equilibration time (1-5 min). A gradient method was developed using acidified water and acetonitrile combined with high column temperature (55 °C) and flow rate (2.5 mL min(-1)). Optimized conditions provided a method for the separation of these three curcuminoids in approximately 1.3 min with a total analysis time (sample-to-sample) of 7 min, including the clean-up and the re-equilibration of the column. Evaluation of chromatographic performance revealed excellent intraday and interday reproducibility (>99%), resolution (>2.23), selectivity (>1.12), peak symmetry (1.24-1.42) while presenting low limits of detection (<0.40 mg L(-1)) and quantification (<1.34 mg L(-1)). The robustness of the method was calculated according to the concentration/dilution of the sample and the injection volume. Several combinations of methanol and ethanol with water as sample solvents were evaluated and the best chromatographic results and extraction rate were obtained using 100% methanol. Finally, the developed method was validated with different extracts of turmeric rhizome and products that use turmeric in their formulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluent.

    Science.gov (United States)

    Ito, Kazuaki; Nomura, Ryosuke; Fujii, Takuya; Tanaka, Masahito; Tsumura, Tomoaki; Shibata, Hiroyuki; Hirokawa, Takeshi

    2012-11-01

    A method was developed for determination of inorganic anions, including nitrite (NO(2)(-)), nitrate (NO(3)(-)), bromide (Br(-)), and iodide (I(-)), in seawater by ion chromatography (IC). The IC system used two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50 × 4.6 mm i.d. and 100 × 4.6 mm i.d.) connected in series for separation of the ions. Aqueous NaCl (0.5 mol/L; flow rate, 3 mL/min) containing 5 mmol/L phosphate buffer (pH 5) was used as the eluent, and detection was with a UV detector at 225 nm. The monolithic ODS columns were coated and equilibrated with a 1-mmol/L DDAB solution (in H(2)O/methanol, 90:10 v/v). The hydrophilic ions (NO(2)(-), NO(3)(-), and Br(-)) were separated within 3 min and the retention time of I(-) was 16 min. No interferences from matrix ions, such as chloride and