WorldWideScience

Sample records for colour tissue doppler

  1. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  2. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  3. Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sørensen, Tor; Søgaard, Peter

    2016-01-01

    BACKGROUND: The current method for a non-invasive assessment of diastolic dysfunction is complex with the use of algorithms of many different echocardiographic parameters. Total average diastolic longitudinal displacement (LD), determined by colour tissue Doppler imaging (TDI) via the measurement...

  4. Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check?

    International Nuclear Information System (INIS)

    Lanza, Cecilia; Fabrizzi, Giancarlo; Russo, Marco

    2006-01-01

    After the insertion of a central venous catheter, a chest radiograph is usually obtained to ensure correct positioning of the catheter tip. To determine in a paediatric population whether B-mode and colour Doppler sonography after central venous access is useful to evaluate catheter position, thus obviating the need for a postprocedural radiograph. A prospective study of 107 consecutive central venous access procedures placed in a paediatric intensive care unit was performed. At the end of the procedure, B-mode and colour Doppler sonography were used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. In 96 patients postprocedural B-mode and colour Doppler sonography showed colour Doppler signals within the vena cava. Among the 11 patients predicted to have a potential complication, there was one pneumothorax and ten malpositions. Chest radiography showed a total of 13 complications - 1 pneumothorax and 12 malpositions. The concordance between colour Doppler sonography and chest radiography was 98.1% in the detection of catheter position; sonography had a sensitivity of 84.6% and a specificity of 100%. The close concordance between B-mode and colour Doppler sonography and chest radiography justifies the more frequent use of sonography to evaluate catheter position because ionizing radiation is eliminated. Chest radiography may then be performed only when there is suspected inappropriate catheter tip position after sonography. (orig.)

  5. The role of colour Doppler sonography in the diagnosis of lower limb Klippel–Trénaunay syndrome

    International Nuclear Information System (INIS)

    Qi, H.T.; Wang, X.M.; Zhang, X.D.; Zhang, M.H.; Li, C.M.; Bao, S.G.; Yuan, H.

    2013-01-01

    Aim: To investigate the accuracy of colour Doppler sonography as compared to phlebography in patients with Klippel-Trénaunay syndrome (KTS). Materials and methods: From September 2004 to May 2012, 59 consecutive patients seen in Shandong medical imaging research institute with a clinical suggestion of KTS were included. Thirty-four were female and 25 were male, with a mean age of 28.4 years. Colour Doppler sonography was used to assess the lower limb veins. The main sonographic criteria for a positive diagnosis were visualization of the lateral vein or sciatic vein, capillary haemangioma, and abnormality of the deep veins. These data were compared with phlebography findings. The κ statistic was used to determine the level of agreement. The sensitivity, specificity, positive and negative predictive values, and accuracy of colour Doppler sonography as a diagnostic test were assessed. Results: Colour Doppler sonography findings were positive in 21 of 59 patients with a clinical suggestion of KTS. The diagnosis was confirmed using phlebography in 22 patients. There were two false-positive results and one false-negative result by colour Doppler sonography. The κ-value was 0.892. Sensitivity, specificity, positive and negative predictive values, and accuracy for colour Doppler sonography were 95.4, 94.6, 91.3, 97.2, and 94.9%, respectively. Conclusion: Colour Doppler sonography is an accurate, reliable, and non-invasive investigation in the assessment of patients with suspected KTS

  6. The role of colour flow Doppler in the investigation of the salivary gland tumour

    International Nuclear Information System (INIS)

    Bradley, M.J.; Durham, L.H.; Lancer, J.M.

    2000-01-01

    AIMS: Ultrasound is a highly effective imaging technique to determine salivary gland tumours and may help to identify many benign lesions. The aim of this study is to evaluate whether colour Doppler is able to further differentiate the malignant tumour. METHODS: Fifty-six patients with salivary gland lesions were prospectively assessed using ultrasound imaging with colour flow and power Doppler. The peak systolic velocity (PSV) was measured and the pulsatility index (PI) and resistive index (RI) calculations were performed on the pulsed wave traces. The real time ultrasound morphology and the Doppler information were correlated with the histology. RESULTS: In 18 of the 56 patients, no internal colour flow or power Doppler changes could be detected. The real time ultrasound morphology diagnosed benign disease with sensitivity of 89.7% with specificity of 57.1%. The positive predictive value was 93.6%. There were no significant differences in the colour Doppler appearances in terms of vessel type or intratumour distribution which could separate benign from malignant conditions. However, there was statistical discrimination for PI and RI values (P = 0.0006, P = 0.0002, respectively). No malignant lesions were seen when the PI was less than 1.8 and RI was less than 0.8. The PSV was elevated in several cases (> 50 cm per s) but there was no statistical correlation with malignancy. CONCLUSION: The risk of malignancy increases by a third when the colour Doppler demonstrates increased intratumour vascular resistance (RI > 0.8 and PI > 1.8), with positive predictive value of 97.3% (sensitivity 75.5%, specificity 85.7%). Bradley, M.J. (2000). Clinical Radiology 55, 759-762

  7. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match.

    Science.gov (United States)

    Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H

    2010-02-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.

  8. Colour doppler ultrasound assessment of the normal neonatal hip

    International Nuclear Information System (INIS)

    Ortiz-Neira, C.L.; Laffan, E.; Daneman, A.; Fong, K.; Roposch, A.

    2009-01-01

    To determine the morphology and hemodynamic characteristics of the arterial vessels of the proximal femur according to specific anatomic regions in asymptomatic neonates in 2 pediatric-based health care institutions. Forty-three neonates (29 female, 14 male; age range, 2 d-3 mo; median age, 3 d) were enrolled in the study. Thirty-two (37%) of 86 hips were classified as Graf type IIA joints (mean alpha angle, 56.0 o ± 2.7 o ), and 54 (63%) were classified as type I joints (mean alpha angle, 65.0 o ± 4.6 o ). Colour and spectral Doppler imaging identified vessels running along the acetabular labrum, epiphyseal vessels, and femoral neck. We showed 4 different patterns of vascularity of the hips: radial, parallel, mixed radial-parallel, and indeterminate, however, they were not related to the hip maturity (P = .3, coronal plane; P = .62, transverse plane) or to the amount of colour pixels identified in each region (P = .35). The mean number of pixels in the ligamentum teres region was significantly higher than that in other regions of interest (P =.03). Except for the acetabular labrum arteries, Doppler spectrum waveforms of proximal femur arteries presented with low resistivity. There was a tendency towards females' acetabular arteries presenting with lower peak systolic velocities than males' acetabular arteries (P =.06). Colour Doppler spectrum waveforms and intensity of vascularity in normal neonatal hips differ according to the anatomic region under evaluation. This observation deserves further investigation on its role on the physiopathogenesis of neonatal hip disorders. (author)

  9. Three-dimensional colour Doppler of ductus venosus agenesis in ...

    African Journals Online (AJOL)

    was bilateral pleural effusion with generalised subcutaneous oedema suggestive of hydrops fetalis (Fig. 1B). Colour Doppler sonography revealed the umbilical vein draining into the portal sinus with non-visualisation of the DV, which would connect the portal sinus with the inferior vena cava (IVC) (Figs 1C and 1D). Hence ...

  10. Validity of colour doppler ultrasonography with d-dimers in clinically suspected deep venous thrombosis of the lower limb

    International Nuclear Information System (INIS)

    Babar, T.H.; Nafees, M.N.; Sarwar, S.; Ashraf, N.

    2010-01-01

    Objective: This study was designed to evaluate the validity of colour Doppler ultrasonography with D-dimers in clinically suspected deep venous thrombosis of the lower limb. Study Design: Validation study Place and Duration of study: Radiology Department CMH/MH Rawalpindi Six months from 15 June 2006 to 31 December 2006. Subjects and Methods: Thirty cases of clinically suspected deep venous thrombosis of the lower limb were included in the study selected on non probability convenience sampling technique. Colour Doppler ultrasonography examination of the affected lower limb was carried out and results compared with D-dimers assays results. Results: Among 30 patients who underwent colour Doppler ultrasonography examination of the affected limb for diagnosis of deep venous thrombosis, 27 (90%) were diagnosed to have deep venous thrombosis, 3 (10%) were diagnosed not to have deep venous thrombosis. Amongst them 2 patients had raised D-dimers levels and repeat Doppler ultrasound advised. On revised ultrasound deep venous thrombosis in these patients was confirmed. This showed that colour Doppler ultrasonography examination has sensitivity of 93.1%, specificity 100%, positive predictive value 100%, negative predictive value 33.33% and overall accuracy of 93.33 %. Conclusion: Colour Doppler ultrasonography has a high diagnostic yield in cases of deep venous thrombosis of lower limb when used in conjunction with D-dimers assays. (author)

  11. The usefulness of ultrasound colour-Doppler twinkling artefact for detecting urolithiasis compared with low dose nonenhanced computerized tomography

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; Kalhauge, Anna; Fredfeldt, Knud-Erik

    2012-01-01

    This prospective study evaluates the usefulness of the twinkling artefact (TA) seen on colour-Doppler ultrasound (US) in diagnosing urolithiasis. US and standard computed tomography (CT) were performed blinded on 105 patients. B-mode US and colour-Doppler used separately and in combination showed...

  12. Tissue Doppler echocardiography improves the diagnosis of coronary artery stenosis in stable angina pectoris

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Jensen, Jan Skov; Iversen, Allan Zeeberg

    2012-01-01

    Aim To determine if colour tissue Doppler imaging (TDI) performed at rest in patients with suspected stable angina pectoris (SAP) is able to predict the presence of significant coronary artery disease (CAD). METHODS AND RESULTS: This study comprises 296 consecutive patients with clinically...... by colour TDI at six mitral annular sites and averaged to provide global estimates. Duke score (DS), including ST depression, chest pain, and exercise capacity, was used as the outcome of the exercise ECG. Patients with an area stenosis of ≥70% in at least one epicardial coronary artery were categorized...

  13. SCROTAL SWELLING- EVALUATION BY HIGH FREQUENCY USG AND COLOUR DOPPLER STUDIES

    Directory of Open Access Journals (Sweden)

    Krishna Kumar Borah

    2017-01-01

    Full Text Available BACKGROUND The aim of the study is to- 1. Study ultrasonographic and colour Doppler patterns of different causes of scrotal swelling (masses. 2. Asses the role of high frequency real time USG in differentiating testicular and extra testicular masses. MATERIALS AND METHODS A hospital-based cross-sectional study of 100 cases of scrotal pathology were studied over a period of 1 year from 1 st August, 2008, to 31 st July, 2009, in the Department of Radiodiagnosis, Assam Medical College Hospital at Dibrugarh. All the patients were subjected to grey scale high resolutions USG of scrotum and then scrotal colour Doppler study. Sonographic imaging was performed with Phillips HD-11 real time scanner by using 2.5-5 MHz curvilinear probe and 10 MHz linear transducer. RESULTS Out of 100 cases of scrotal swelling- 97% were benign, 3% were malignant. Among the benign lesions, 82% cases were extra testicular, 7% intratesticular, 8% are both intra and extra testicular in origin. 100% of all malignant lesions were intratesticular. Of the benign lesion- 40% hydrocele, 26% inflammatory lesions, 5% hernia, 6% varicocele, 4% traumatic, 5% cases epididymal cyst, 2% cases torsion. CONCLUSION High resolution, high frequency US and colour Doppler study of scrotum had the advantages of being noninvasiveness, lack of ionising radiation, wide availability, cost effectiveness and repeatability. It is accurate in differentiating testicular ischaemia and torsion, solid and cystic, benign and malignant mass. It is highly sensitive in demonstrating varicocele.

  14. Grey-scale and colour Doppler ultrasound versus magnetic resonance imaging for the prenatal diagnosis of placenta accreta.

    Science.gov (United States)

    Rezk, Mohamed Abd-Allah; Shawky, Mohamed

    2016-01-01

    To assess the effectiveness of grey-scale and colour Doppler ultrasound (US) versus magnetic resonance imaging (MRI) for the prenatal diagnosis of placenta accreta. A prospective observational study including a total of 74 patients with placenta previa and previous uterine scar (n = 74). Grey-scale and colour Doppler US was done followed by MRI by different observers to diagnose adherent placenta. Test validity of US and MRI were calculated. Maternal morbidity and mortality were also assessed. A total of 53 patients confirmed to have placenta accreta at operation. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US was 94.34, 91.67, 96.15 and 88% compared to 96.08, 87.50, 94.23 and 91.3% for MRI, respectively. The most relevant US sign was turbulent blood flow by colour Doppler, while dark intra-placental band was the most sensitive MRI sign. Venous thromboembolism (1.3%), bladder injury (29.7%), ureteric injury (18.9%), postoperative fever (10.8%), admission to ICU (50%) and re-operation (31.1%). Placenta accreta can be successfully diagnosed by grey-scale and colour Doppler US. MRI would be more likely suggested for either posteriorly or laterally situated placenta previa in order to exclude placental invasion.

  15. D-dimer assay for deep vein thrombosis: its role with colour Doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, M.; Bladon, J.; Barker, H

    2000-07-01

    AIM: To evaluate the role of a negative D-dimer assay in the initial management of patients with clinically suspected deep venous thrombosis (DVT), using colour Doppler ultrasound as the primary diagnostic technique. MATERIALS AND METHODS: A double-blind prospective trial was performed on 143 patients with clinically suspected DVT. All patients underwent a D-dimer assay prior to anticoagulant therapy. DVT was confirmed or excluded by diagnostic colour Doppler ultrasound within 24 h of presentation. RESULTS: In nearly one-third of the cases (31.8%), Doppler ultrasound was positive. The D-dimer assay demonstrated a sensitivity of 97.7% with only one false-negative, but the specificity was low at 48.9% with 45 false-positive results. The positive predictive value for D-dimer assay was 48.8%, whilst the important negative predictive value was 98%. CONCLUSION: If D-dimer was used to screen for DVT, and patients with negative results were not imaged, then the imaging workload could be reduced by 35%. In this study one small calf vein thrombus would have been missed by adopting this practice. Bradley, M. (2000)

  16. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  17. Effect of glucocorticosteroid injections in tennis elbow verified on colour Doppler ultrasonography: evidence of inflammation

    DEFF Research Database (Denmark)

    Torp-Pedersen, T.E.; Torp-Pedersen, S.T.; Qvistgaard, E.

    2008-01-01

    were evaluated at baseline before the injection and at 2 weeks of follow-up. Outcome measures were changes in pain score and US parameters (resistive index (RI) and the amount of colour within the CEO). Prognosticators for outcome were: use of computer mouse, symptom duration, elbow strain, RI, colour...... fraction, Likert pain score, pain at rest, pain during activity, age, height, weight, disease in dominant versus nondominant arm. RESULTS: All but one patient experienced improvement of general elbow pain perception at follow-up at 2 weeks. In parallel, Doppler US showed significant reduction in colour...

  18. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance.

    Science.gov (United States)

    Park, A Y; Seo, B K; Woo, O H; Jung, K S; Cho, K R; Park, E K; Cha, S H; Cha, J

    2018-03-01

    To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance. A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined. SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (ppower Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; ppower Doppler US for characterising the vascularity in breast masses and improving diagnostic performance. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Quantification of colour Doppler activity in the wrist in patients with rheumatoid arthritis - the reliability of different methods for image selection and evaluation

    DEFF Research Database (Denmark)

    Ellegaard, K.; Torp-Pedersen, S.; Lund, H.

    2008-01-01

    measurements in the wrist of patients with rheumatoid arthritis (RA) using different selection and quantification methods. Materials and Methods: 14 patients with RA had their wrist scanned twice by the same investigator with an interval of 30 Minutes, The images for analysis were selected either......Purpose: The amount Of colour Doppler activity in the inflamed synovium is used to quantity inflammatory activity. The measurements may vary due to image selection, quantification method, and point in cardiac cycle. This study investigated the test-retest reliability Of ultrasound colour Doppler...... was obtained when the images were selected guided by colour Doppler and the Subsequent quantification was (done in an area defined by anatomical Structures. With this method, the intra-class coefficient ICC (2.1) was 0.95 and the within-subject SD (SW) was 0.017, indicating good reliability. In contrast, poor...

  20. Comparison of CT scan and colour flow doppler ultrasound in detecting venous tumour thrombous in renal cell carcinoma

    International Nuclear Information System (INIS)

    Khan, A.R.; Anwar, K.

    2008-01-01

    Renal cell carcinoma has marked tendency to spread into renal vein, inferior vena cava and right side of heart. Extension of tumour thrombus into these veins will alter the surgical approach. We have compared the CT scan with Colour flow Doppler ultrasound in detecting venous tumour thrombus in renal vein and inferior vena cava. This cross-sectional study included 30 adult patients presenting with renal tumour. Patients of either gender were included in the study. Non probability convenience sampling was used. All patients underwent colour flow Doppler ultrasound and CT scan with contrast to asses the renal vein and inferior vena cava. The results were confirmed by intra operative findings and histopathology. The data was analyzed using SPSS version 12. Out of 30 patients, 20 (66%) were males and 10 (34%) female. The tumour was predominantly on the right side (60%), as was renal venous tumour thrombus (44%). Inferior vena cava was involved in 4 cases predominantly due to right sided tumours. The sensitivity of Doppler ultrasound in detecting renal venous tumour thrombus (88% on right and 100% on left side) was higher than CT scan (63% on right and 60% on left side). Doppler ultrasound was also superior to CT scan in detecting vena caval thrombus. The overall sensitivity of Doppler sonography was higher than CT scan in detecting tumour extension into renal veins and inferior vena cava. Therefore, it can be used as a complementary tool in equivocal cases. (author)

  1. Colour Doppler evaluation of extracranial carotid artery in patients presenting with features of cerebrovascular disease: A clinical and radiological correlation

    Directory of Open Access Journals (Sweden)

    Sanjeev Sehrawat

    2012-01-01

    Full Text Available Aim: To evaluate the morphological and hemodynamic changes that take place in carotid arteries by colour Doppler in patients presenting with features of stroke. Background and Objectives: Cerebrovascular accidents constitute a major cause of adult mortality. The principal indication for cerebrovascular Doppler examination is stroke prevention. Colour Doppler sonography is a sensitive method for detection of atherosclerotic plaque and provides considerable information about the extent and severity of plaque as well as the resulting diminution of arterial lumen. The main strengths of sonography of carotid arteries are patient comfort, lack of risk and accuracy in detecting carotid stenosis. Material and Methods: A prospective study of Colour Doppler in carotid arteries was carried out for 12 months from 1 st July 2009 to 1 st July 2010. The study was carried out on 40 individuals, suspected of cerebrovascular insufficiency and having one or the other risk factors for cerebrovascular disease. A detailed clinical history, CNS examination findings and evidence of hypertension, diabetes mellitus, hyperlipidemia and ischemic heart disease were noted. Carotid Doppler evaluation was done by using Siemens Antares Ultrasound system. The data gathered were grey scale and Doppler findings of common carotid artery, internal carotid artery and external carotid arteries. Doppler findings were correlated with clinical features and risk factors. Results: In our study of 40 patients, the commonest lesion found was the atherosclerotic plaque. Highest incidence of plaque was seen in males 41% in the age group of 60-70 years and in females 37% in age group of 70-80 years. Cigarette smoking was the most common risk factor (60% associated with stroke/ Transient Ischaemic Attacks (TIA. Hemiparesis was the most common presenting symptom (35% among the symptomatic cases. Atheromatous plaque was most commonly found in the right carotid system (60%. Most common site for

  2. Relationship between colour flow Doppler sonographic assessment of corpus luteum activity and progesterone concentrations in mares after embryo transfer

    NARCIS (Netherlands)

    Brogan, P. T.; Henning, H.; Stout, T. A E; de Ruijter-Villani, M.

    2016-01-01

    Colour-flow Doppler sonography has been described as a means of assessing corpus luteum (CL) function rapidly, because area of luteal blood vessels correlates well with circulating progesterone (P4) concentrations [P4] in oestrous cycling mares. The aim of this study was to assess the relationships

  3. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  4. Pulsed-wave tissue Doppler and color tissue Doppler echocardiography: calibration with M-mode, agreement, and reproducibility in a clinical setting

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Jons, Christian; Fritz-Hansen, Thomas

    2009-01-01

    BACKGROUND: Myocardial velocities can be measured with both pulsed-wave tissue Doppler (PWTD) and color tissue Doppler (CTD) echocardiography. We aimed to (A) to explore which of the two methods better approximates true tissue motion and (B) to examine the agreement and the reproducibility...... of the two methods in a routine clinical setting. METHODS: For Study A, the displacements of 63 basal myocardial segments from 13 patients were examined with M-mode and compared with the velocity-time integral of PWTD and CTD velocities. For Study B, the basal lateral segments from 58 patients were examined...... with PWTD and CTD, and the peak myocardial velocities during systole (Sm), early diastole (Em), and late diastole (Am) were measured. RESULTS: Study A: CTD-based measurements of displacement were 12% lower than M-mode measurements (95% CI: -18%; -6%). PWTD velocity-time integrals measured at the outer edge...

  5. Influence of detomidine on atrial fibrillation cycle length measured by intracardiac electrogram recording and by colour tissue Doppler imaging in horses.

    Science.gov (United States)

    Decloedt, A; de Clercq, D; van der Vekens, N; Verheyen, T; Ven, S; van Loon, G

    2016-01-01

    Shortening of atrial fibrillation cycle length (AFCL) is a marker of atrial electrical remodelling due to atrial fibrillation (AF). To investigate the effect of administration of detomidine on AFCL measured invasively from an intra-atrial electrogram (AFCLEGM) and noninvasively by tissue Doppler imaging (AFCLTDI). We hypothesised that detomidine would have no effect on AFCL but would improve the ease of TDI measurements and facilitate noninvasive AFCL determination. Prospective clinical study. Measurements were performed before and after i.v. administration of 7.5 μg/kg bwt detomidine in 33 episodes of AF in 32 horses (582 ± 64 kg bwt, 10 ± 3 years old) referred for electrical cardioversion. The AFCLEGM was measured from a right atrial intracardiac electrogram. The AFCLTDI was measured from atrial colour tissue velocity curves in 5 atrial wall regions. Mean AFCLEGM and AFCLTDI without and with sedation were compared using a repeated-measures linear mixed model with Bonferroni correction for multiple comparisons and calculation of the Bland-Altman mean bias and limits of agreement between AFCLEGM and AFCLTDI. The mean AFCL was significantly increased after sedation, but this increase was very small (mean difference +4 ms). For AFCLTDI measurements, sedation significantly improved the quality of the atrial myocardial velocity curves and the number of AF cycles that could be measured per cardiac cycle. The Bland-Altman bias between AFCLEGM without sedation and AFCLTDI with sedation ranged from -18 to +15 ms depending on wall region. Bland-Altman limits of agreement were similar between AFCLEGM without sedation and AFCLTDI without and with sedation. Therefore, noninvasive AFCLTDI measurements with sedation can be used to estimate the atrial fibrillatory rate. Sedation facilitates noninvasive AFCL measurements but causes a slight increase in AFCL. Noninvasive AFCL measurements can be used as an indicator of atrial electrical remodelling, to study AF

  6. The Assessment of Left Ventricular Time-Varying Radius Using Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Fardin Mirbolouk

    2012-03-01

    Full Text Available Background: Left ventricular twist/torsion is believed to be a sensitive indicator of systolic and diastolic performance. To obtain circumferential rotation using tissue Doppler imaging, we need to estimate the time-varying radius of the left ventricle throughout the cardiac cycle to convert the tangential velocity into angular velocity. Objectives: The aim of this study was to investigate accuracy of measured LV radius using tissue Doppler imaging throughout the cardiac cycle compared to two-dimensional (2D imaging. Methods: A total of 35 subjects (47±12 years old underwent transthoracic echocardiographic standard examinations. Left ventricular radius during complete cardiac cycle measured using tissue Doppler and 2D-imaging at basal and apical short axis levels. For this reason, the 2D-images and velocity-time data derived and transferred to a personal computer for off-line analysis. 2D image frames analyzed via a program written in the MATLAB software. Velocity-time data from anteroseptal at basal level (or anterior wall at apical level and posterior walls transferred to a spreadsheet Excel program for the radius calculations. Linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the tissue Doppler and 2D-measured radii throughout the cardiac cycle. Results: There was significant correlation between tissue Doppler and 2D-measured radii and the Pearson correlation coefficients were 0.84 to 0.97 (P<0.05. Bland-Altman analysis by constructing the 95% limits of agreement showed that the good agreements existed between the two methods. Conclusion: It can be concluded from our experience that the tissue Doppler imaging can reasonably estimate radius of the left ventricle throughout the cardiac cycle.

  7. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  8. Tissue doppler echocardiography for evaluating left ventricular functions in obese

    Directory of Open Access Journals (Sweden)

    Mecnun Çetin

    2013-03-01

    Full Text Available Objective: The aim of this study was to investigate theimpact of childhood obesity on ventricular functions usingtissue Doppler echocardiography.Materials and methods: The mitral tissue Doppler signalswere recorded in the apical four-chamber view, with thesample volume placed at the lateral walls of mitral annulus.The mitral flow was examined with the sample Pulse Dopplerpositioned parallely to flow just at the orifice of the mitralleaflets. Twenty obese (mean age, 161.5±25.8 monthsand 20 healthy children (mean age, 151.2±33.5 monthswere included to this study.Results: Body mass index (BMI was significantly higherin obese group (30.92±6.87. Isovolumic relaxation time(IVRT which is one of the left ventricular (LV diastolicfunction parameters was 66.10±7.30 ms in obese group,and 58.70±9.06 ms in the control group. IVRT was significantlyhigher in the obese group (p=0.007. In obesegroup, the mitral annulus tissue Doppler E velocity wasdecreased, flow velocity was increased and decrement inEm/Am ratio was significant. We found significant negativecorrelation between BMI and LV Em/Am ratio. Myocardialperformance index (MPI in obese group and control groupwas 0.50±0.07 and 0.41±0.04, respectively (p<0.001.Between MPI and LV Em/Am ratio there was a significantnegative correlation while MPI showed positive correlationwith BMI. In obese group septal and LV posterior wall thicknesswas shown to be significantly increased compared tothe control group (p<0.001.Conclusion: Our findings, may be important for determinationof the relationship between obesity and cardiovascularrisk factors in children. Tissue Doppler echocardiographicimaging may be useful in revealing this relationship.Key words: obesity, doppler echocardiography, ventricular dysfunction

  9. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  10. Prognostic value of systolic mitral annular velocity measured with Doppler tissue imaging in patients with chronic heart failure caused by left ventricular systolic dysfunction

    Science.gov (United States)

    Nikitin, N P; Loh, P H; de Silva, R; Ghosh, J; Khaleva, O Y; Goode, K; Rigby, A S; Alamgir, F; Clark, A L; Cleland, J G F

    2006-01-01

    Objective To assess the prognostic value of various conventional and novel echocardiographic indices in patients with chronic heart failure (CHF) caused by left ventricular (LV) systolic dysfunction. Methods 185 patients with a mean (SD) age of 67 (11) years with CHF and LV ejection fraction < 45% despite optimal pharmacological treatment were prospectively enrolled. The patients underwent two dimensional echocardiography with tissue harmonic imaging to assess global LV systolic function and obtain volumetric data. Transmitral flow was assessed with conventional pulse wave Doppler. Systolic (Sm), early, and late diastolic mitral annular velocities were measured with the use of colour coded Doppler tissue imaging. Results During a median follow up of 32 months (range 24–38 months in survivors), 34 patients died and one underwent heart transplantation. Sm velocity (hazard ratio (HR) 0.648, 95% confidence interval (CI) 0.463 to 0.907, p  =  0.011), diastolic arterial pressure (HR 0.965, 95% CI 0.938 to 0.993, p  =  0.015), serum creatinine (HR 1.006, 95% CI 1.001 to 1.011, p  =  0.023), LV ejection fraction (HR 0.945, 95% CI 0.899 to 0.992, p  =  0.024), age (HR 1.035, 95% CI 1.000 to 1.071, p  =  0.052), LV end systolic volume index (HR 1.009, 95% CI 0.999 to 1.019, p  =  0.067), and restrictive pattern of transmitral flow (HR 0.543, 95% CI 0.278 to 1.061, p  =  0.074) predicted the outcome of death or transplantation on univariate analysis. On multivariate analysis, only Sm velocity (HR 0.648, 95% CI 0.460 to 0.912, p  =  0.013) and diastolic arterial pressure (HR 0.966, 95% CI 0.938 to 0.994, p  =  0.016) emerged as independent predictors of outcome. Conclusions In patients with CHF and LV systolic dysfunction despite optimal pharmacological treatment, the strongest independent echocardiographic predictor of prognosis was Sm velocity measured with quantitative colour coded Doppler tissue

  11. Cardiac Time Intervals by Tissue Doppler Imaging M-Mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; de Knegt, Martina Chantal

    2016-01-01

    PURPOSE: To define normal values of the cardiac time intervals obtained by tissue Doppler imaging (TDI) M-mode through the mitral valve (MV). Furthermore, to evaluate the association of the myocardial performance index (MPI) obtained by TDI M-mode (MPITDI) and the conventional method of obtaining...

  12. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  13. Concordance and reproducibility between M-mode, tissue Doppler imaging, and two-dimensional strain imaging in the assessment of mitral annular displacement and velocity in patients with various heart conditions

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sorensen, Tor; Sogaard, Peter

    2014-01-01

    AIMS: Mitral annular (MA) displacement reflects longitudinal left ventricular (LV) deformation and systolic velocity measurements reflect the rate of contraction; both are valuable in the diagnosis and prognosis of cardiac disease. The aim of this study was to test the agreement and reproducibility...... between motion mode (M-mode), colour tissue Doppler imaging (TDI), and two-dimensional strain imaging (2DSI) when measuring MA displacement and systolic velocity. METHODS AND RESULTS: Using GE Healthcare Vivid 7 and E9 and Echopac BT11 software, MA displacement and velocity measurements by 2DSI, TDI...

  14. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Pyshnyi, Michael Ph. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation); Kuznetsov, Oleg A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)], E-mail: kuznetsov_oa@yahoo.com; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)

    2009-05-15

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  15. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    International Nuclear Information System (INIS)

    Pyshnyi, Michael Ph.; Kuznetsov, Oleg A.; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A.

    2009-01-01

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  16. Colour Doppler analysis of ophthalmic vessels in the diagnosis of carotic artery and retinal vein occlusion, diabetic retinopathy and glaucoma: systematic review of test accuracy studies.

    Science.gov (United States)

    Bittner, Mario; Faes, Livia; Boehni, Sophie C; Bachmann, Lucas M; Schlingemann, Reinier O; Schmid, Martin K

    2016-12-07

    Colour Doppler analysis of ophthalmic vessels has been proposed as a promising tool in the diagnosis of various eye diseases, but the available diagnostic evidence has not yet been assessed systematically. We performed a comprehensive systematic review of the literature on the diagnostic properties of Colour Doppler imaging (CDI) assessing ophthalmic vessels and provide an inventory of the available evidence. Eligible papers were searched electronically in (Pre) Medline, Embase and Scopus, and via cross-checking of reference lists. The minimum requirement to be included was the availability of original data and the possibility to construct a two-by-two table. Study selection, critical appraisal using the QUADAS II instrument and extraction of salient study characteristics was made in duplicate. Sensitivity and specificity was computed for each study. We included 11 studies (15 two-by-two tables) of moderate methodological quality enrolling 820 participants (range 30 to 118). In 44.4% participants were female (range 37-59% in specific subgroups). CDI was assessed for internal carotid stenosis, diabetic retinopathy, glaucoma, and branch or central retinal vein occlusion diagnosis. There was insufficient data to pool the results for specific illnesses. For the assessments of ophthalmic arteries, mean sensitivity was 0.69 (range 0.27-0.96) with a corresponding mean specificity of 0.83 (range 0.70-0.96). Mean sensitivity of the central retinal artery assessments was 0.58 (range 0.31-0.84) and the corresponding mean specificity was 0.82 (range 0.63-0.94). Robust assessments of the diagnostic value of colour Doppler analysis remain uncommon, limiting the possibilities to extrapolate its true potential for clinical practice. PROSPERO 2014:CRD42014014027.

  17. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  18. Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access

    International Nuclear Information System (INIS)

    Pietura, Radoslaw; Janczarek, Marzena; Zaluska, Wojciech; Szymanska, Anna; Janicka, Lucyna; Skublewska-Bednarek, Anna; Szczerbo-Trojanowska, Malgorzata

    2005-01-01

    Background: A well-functioning mature arteriovenous fistula is essential for the maintenance of haemodialysis in patients with chronic renal failure. The Brescia-Cimino arteriovenous fistula has the best survival characteristics and low rate of complications. The most common reason of fistula failure is thrombosis caused by stenosis. Colour Doppler ultrasonography has proven to be effective in the assessment of anatomical vascular features. The majority of studies were done in patients with clinically presumed arteriovenous fistula complications. However, only limited data are available about the well-functioning mature arteriovenous fistulas. The purpose of the present study was to evaluate completely asymptomatic, mature arteriovenous fistulas with colour Doppler ultrasound. Materials and methods: From July 2001 to April 2003, we examined 139 patients with the end-stage renal disease. They were in the range of 19-79 years of age (mean, 46.7 years). The study included only the patients who met the following criteria: (1) no difficulties with haemodialysis (as reported by nurses); (2) normal venous diastolic blood pressure (<150 mmHg) at monthly evaluation; (3) normal urea clearance x time/urea volume of distribution; (4) blood cells count, plasma electrolytes, and liver function at monthly evaluation. The mean fistula age was 26 months (S.D. = 21.9). The mean time of dialysis therapy was 49 months. Thirty-eight percent patients had primary fistulas, 23%-secondary, 11%-third and 11%-fourth, 4%-fifth, 5%-sixth, and 8% patients had more than sixth. Results: There was no correlation between: (1) patient's age and fistula age; (2) patient's age and number of fistulas in one patient; (3) fistula age and number of fistulas in one patient; (4) localization of fistula and fistula age. There was a strong correlation between dialysis therapy period and number of fistulas in one patient. The mean flow volume was 1204.1 ml/min (S.D. = 554). It was significantly higher in the

  19. Does ultrasound contrast agent improve the diagnostic value of colour and power Doppler sonography in superficial lymph node enlargement?

    International Nuclear Information System (INIS)

    Schulte-Altedorneburg, Gernot; Demharter, Johannes; Linne, Renate; Droste, Dirk W.; Bohndorf, Klaus; Buecklein, Wolfgang

    2003-01-01

    Objective: to analyse whether ultrasound contrast agent (UCA) improves the diagnostic accuracy to differentiate between benign and malignant superficial lymph node enlargement by using colour-coded duplex sonography (CCDS) and power Doppler (PD). Methods: 32 patients with suspected malignant superficial lymph node enlargement prospectively underwent standardised ultrasound examinations using B-mode sonography and native and contrast-enhanced CCDS and PD immediately before biopsy. Solbiati-Index (longitudinal-transverse diameter ratio) and intranodal flow patterns by using different vascularisation types were assessed. Histological and sonographical findings were correlated. Results: 27 malignant and 5 benign lymph nodes were found. Solbiati-Index was lower in malignant lymph nodes than in benign nodes (mean 1.5 vs. 2.4, P<0.045). More intranodal flow patterns could be detected after UCA (53 vs. 43) but the number of correctly identified malignant nodes decreased after UCA (26 vs. 24) and the number of correctly identified benign nodes remained constant compared with native CCDS and PD. In 31% of the colour-mode studies, PD was considered to visualise more clearly intranodal vascular flow patterns than CCDS. Conclusion: despite depicting more intranodal vascular patterns, the use of an ultrasound contrast agent seems not to improve the diagnostic value of CCDS and PD compared with native colour-mode studies in superficial lymph node enlargement

  20. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    Science.gov (United States)

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  1. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  2. Pulsed and Tissue Doppler Echocardiographic Changes in Patients with Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Taysir S. Garadah

    2010-01-01

    Full Text Available Background Doppler echocardiographic studies of left ventricle (LV systolic and diastolic function in patients with β-Thalassemia Major (β-TM had shown different patterns of systolic and diastolic dysfunction. Aim This cross-sectional study was designed to study the LV systolic and diastolic function in patients with β-TM using Pulsed Doppler (PD and Tissue Doppler (TD echocardiography. Methods All patients were evaluated clinically and by echocardiography, The study included patients with β-TM (n = 38, age 15.7 ± 8.9 years compared with an age-matched control group (n = 38, age 15.9 ± 8.9 years. The pulse Doppler indices were normalized for age and heart rate. Results Compared with control patients, M-Mode showed that patients with β-TM have thicker LV septal wall index (0.659 ± 0.23 vs. 0.446 ± 0.219 cm, P ≤ 0.001, posterior wall index (0.659 ± 0.235 vs. 0.437 ± 0.214 cm, P ≤ 0.01, and larger LVEDD index is (3.99 ± 0.48 vs. 2.170 ± 0.57 mm. P = 0.035. Pulsed Doppler showed high LV trans-mitral E wave velocity (70.818 ± 10.139 vs. 57.532 ± 10.139, p = 0.027 and E/A ratio (1.54 vs. 1.23, P ≤ 0.01. The duration of Deceleration time (DT and isovolumic relaxation time (IVRT were significantly shorter in patients with β-TM (150.234 ± 20.0.23 vs. 167.123 ± 19.143 msec, P ≤ 0.01 and (60.647 ± 6.77 vs. 75.474 ± 5.83 msec, P ≤ 0.001, respectively. The ratio of transmitral E wave velocity to the tissue Doppler E wave at the basal septal mitral annulus E/Em – was significantly higher in β-TM group (14.024 ± 2.29 vs. 12.132 ± 1.82, P ≤ 0.01. The Tissue Doppler systolic velocity (Sm and the early diastolic velocity (Em were significantly lower in β-TM group compared to control (4.31 ± 1.2 cm/s vs. 6.95 ± 2.1, P ≤ 0.01 and 4.31 ± 2.7 cm/s vs. 5.82 ± 2.5, P ≤ 0.01 respectively. The tricuspid valve velocity was significantly higher than controls (2.993 ± 0.569 vs. 1.93 ± 0.471 m/sec, respectively, P ≤ 0

  3. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  4. Tissue Doppler echocardiography reveals impaired cardiac function in patients with reversible ischaemia

    DEFF Research Database (Denmark)

    Hoffmann, Søren; Mogelvang, Rasmus; Sogaard, Peter

    2011-01-01

    AIMS: To determine if echocardiographic tissue Doppler imaging (TDI) performed at rest detects reduced myocardial function in patients with reversible ischaemia. METHODS AND RESULTS: Eighty-four patients with angina pectoris, no previous history of ischaemic heart disease and normal left ventricu...

  5. The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model

    Science.gov (United States)

    Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D

    2017-01-01

    Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468

  6. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  7. The duplex-Doppler colour echography of the scrotum and testicles in adults and boys. III. Assessment of chronic scrotal pathology

    International Nuclear Information System (INIS)

    Rangel-Villalobos, E.; Benjumeda, A.; Jimenez-Castellanos, R.; Linares, A.; Blanco, A

    1999-01-01

    To show the most outstanding findings from the chronic scrotal pathology of adults and boys, determining the benefits of the Doppler echography in the diagnostical valuation of the different cases analysed. 40 patients (19 adults and 21 boys) with chronic scrotal symptomatology were examined using a B mode echography followed by a colour duplex-Doppler (CDD) echography with a lineal 7.5 MHz transducer. We compared the findings obtained with those corresponding to the contralateral testicle and, depending on the pathology, we co-related them with surgery, pathologic anatomy or clinical-echograph evolution. The pathology found was very varied, it was distributed into: varicoceles (12), testicle tumours (9), extra-testicle tumours (4) and miscellaneous pathology (13). Two patients showed no changes, currently remaining asymptomatic. The treatment was surgical in 28 (70%) of the patients and traditional in the others. The B mode echography played a fundamental role in the diagnosis of chronic scrotal pathology, which in the majority of the cases was definitive, being completed with the application of the Doppler echograph to analyse the vascular condition of the lesions and the anatomical structures. The diagnosis utility of the CDD echograph in chronic scrotal pathology is controversial, it is not specific for testicle tumors, it is very useful for variocele and complementary, tp the B mode echograph for miscellaneous pathology. (Author) 31 refs

  8. Cardiac Time Intervals Measured by Tissue Doppler Imaging M-mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Schnohr, Peter

    2016-01-01

    function was evaluated in 1915 participants by using both conventional echocardiography and tissue Doppler imaging (TDI). The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT), and ejection time (ET), were obtained by TDI M-mode through the mitral......). Additionally, they displayed a significant dose-response relationship, between increasing severity of elevated blood pressure and increasing left ventricular mass index (P

  9. Angiosonography in suspicious breast lesions with non-diagnostic FNAC: comparison with power Doppler US.

    Science.gov (United States)

    Caumo, F; Carbognin, G; Casarin, A; Pinali, L; Vasori, S; D'Onofrio, M; Pozzi Mucelli, R

    2006-02-01

    The purpose of this study was to evaluate the accuracy of angiosonography in comparison with colour Doppler ultrasound (US) in the discrimination of suspicious breast lesions with nondiagnostic fine-needle aspiration cytology (FNAC). Pre-operative Power Doppler US and angiosonography were prospectively performed in 20 suspicious breast lesions with non-diagnostic FNAC. A second-generation US contrast agent was utilised with a high-frequency transducer and a contrast-specific algorithm (low acoustic pressure CnTI). The enhancement characteristics of all lesions were analysed using qualitative and quantitative parameters obtained from time-intensity curves with the different imaging modalities. The final diagnosis was confirmed at pathology in all cases. Microvessel density (MVD) was assessed in the surgical specimen using CD34. The correct assessment of biological behaviour was achieved in all cases by angiosonography (sensitivity of 100%; specificity of 91%) and colour Doppler US (45% sensitivity; 78% specificity). MVD correlated with the biological behaviour. Angiosonography is more accurate than colour Doppler US in the correct assessment of biological behaviour of suspicious breast lesions.

  10. Evaluation of regional wall motion abnormalities of the heart. Comparison with Doppler tissue echocardiography, MR-tagging and levocardiography

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Hamm, B.; Borges, A.C.; Walde, T.; Rutsch, W.; Baumann, G.

    2004-01-01

    Purpose: To compare the visual analysis of magnetic resonance imaging (MRI) with the tagging technique and Doppler tissue echocardiography with invasive ventriculography in detecting and quantifying regional left ventricular wall motion abnormalities. Materials and Methods: Sixteen patients with coronary artery disease and a history of prior myocardial infarction underwent invasive ventriculography. Doppler tissue echocardiography and MR-tagging within one week. Regional wall motion abnormalities (WMA) were detected in all patients. WMA were graded as normal=1; hypokinetic=2; akinetic=3; or dyskinetic=4. For agreement between MRI, echocardiography, and ventriculography the kappa coefficient (κ) according to Cohen was calculated. Results: The kappa coefficient (κ) was 0.962 for agreement between MRI and echocardiography and 0.602 for agreement between MRI and ventriculography as well as between echocardiography and ventriculography. Conclusion: Reliable analysis of regional left ventricular wall motion abnormalities is feasible using visual analysis of MR-tagging. MRI and Doppler tissue echocardiography detect more WMA than invasive ventriculography and grade them as more severe. (orig.)

  11. The duplex-Doppler colour echography of the scrotum and testicles in adults and boys. II. the contribution of the urgent study of acute scrotum symptoms

    International Nuclear Information System (INIS)

    Rangel-Villalobos, E.; Jimenez-Castellanos, R.; Bustos, C.; Linares, A.; Gonzalez-Prada, F.

    1999-01-01

    To analyse the findings, contributions and limitations of the Doppler echography for the urgent study of acute scrotum symptoms, both in adults and in boys. 60 patients (22 adults and 38 boys) with acute scrotal symptomatology were examined using B mode echography, followed by a colour duplex-Doppler (CDD) echography with a lineal 7.5 MHz transducer. We compared the findings obtained with those of the healthy contralateral testicle and with surgery or clinical-echographical evolution. The most common pathology was inflammation (27%) followed by ischemic (24%) and traumatic (17%). 12% of the patients had miscellaneous conditions. To conclude, in 20% of the cases the B mode and the Doppler examination was normal, the symptoms were resolved spontaneously. After carrying out the CDD only 14 (23%) of the cases needed immediate surgery and 3 (5%) delayed surgery, the remaining 43 (72%) patients responded to the traditional treatment. The CDD allows for a safe, quick and harmless diagnosis in practically all the acute scrotum cases, for both adults and boys. Its limitations in pre-puberty patients or in cases that were atypical are overcome when put in the hands of an expert radiologist, as they need a longer exploration time and suitable Doppler equipment. The main contribution to the urgent diagnosis of acute scrotum symptoms is that it accurately establishes which patients should be chosen for immediate surgery. (Author) 33 refs

  12. Colour Doppler ultrasonography evaluation of vascularization in the wrist and finger joints in rheumatoid arthritis patients and healthy subjects

    Energy Technology Data Exchange (ETDEWEB)

    Carotti, M. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Salaffi, F., E-mail: fsalaff@tin.it [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Morbiducci, J. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Ciapetti, A., E-mail: ciapetti.a@libero.it [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Bartolucci, L. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Gasparini, S. [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Ferraccioli, G. [Division of Rheumatology, Catholic University of the Sacred Heart, Rome (Italy); Giuseppetti, G.M. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Grassi, W. [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy)

    2012-08-15

    Objectives: To evaluate the presence of blood flow by colour Doppler ultrasonography (CDUS) in the wrist and finger joints of rheumatoid arthritis (RA) patients and healthy subjects and to define a cut-off value of CDUS resistive index (RI). Methods: Forty-three patients with RA and 43 healthy controls were examined by CDUS. The wrists, second and third metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints were evaluated in each patient and healthy subject. Spectral Doppler analysis was performed in order to characterize the type of flow and a mean RI was measured to define a cut-off level. The area under receiver operating characteristic curve was used to evaluate the screening method's performance. Results: Flow was detected in 219 of the 430 total joints (50.9%) of RA patients (111 in the wrists, 49 in the MCP and 30 in the PIP joints). Healthy subjects had a quantifiable flow in 45 of the 430 joints (10.5%) and, in particular, 39 (86.4%) in the wrist, 5 (11.14%) in the MCP and 1 (2.2%) in the PIP joints. The intra- and inter-reader agreements for the detection of Doppler signal were very good (kappa 0.82 and 0.89, respectively). Mean RI values were 0.72 {+-} 0.06 in RA patients and 0.86 {+-} 0.06 in healthy subjects (p < 0.01). At cut-off point of RI < 0.79 the sensitivity was 89.6% and the specificity was 78.8% (positive likelihood ratio 4.22). Conclusion: DUS is a useful tool for the detection of abnormal blood flow in inflammatory joints of RA patients.

  13. Colour doppler ultrasonography and sclerosing therapy in diagnosis and treatment of tendinopathy in horses-a research model for human medicine

    DEFF Research Database (Denmark)

    Boesen, Morten Ilum; Nanni, Simone; Langberg, Henning

    2007-01-01

    Sclerosing therapy has in recent studies showed promising results in patients with clinically and ultrasonographically diagnosed tendinosis in Achilles and patellar tendons. The aim of this investigation was to study the presence of intratendinous colour Doppler (CD) flow in horses with clinically...... diagnosed chronic tendinopathy and to test if experience from human studies could be extrapolated to horses. Special interest was focused on the treatment with sclerosing therapy and whether we could obtain the same successful peroperative findings as in humans. Four horses with clinically diagnosed...... unilateral chronic tendinosis in the forelimbs were examinated with both grey-scale ultrasonography (US) and CD. The horses were to be euthanised according to standard procedure is such cases. The US findings were used for guidance of sclerosing therapy. All horses showed abnormal findings on US, especially...

  14. Systolic and Diastolic Function by Tissue Doppler Imaging Predicts Mortality in Patients with Atrial Fibrillation

    DEFF Research Database (Denmark)

    Dons, Maria; BieringSørensen, Tor; Jensen, Jan Skov

    2015-01-01

    AIM: Tissue Doppler Imaging (TDI) detects early signs of left ventricular dysfunction. The prognostic potential of TDI in patients with atrial fibrillation (AF) has, however, not yet been clarified. This study evaluates the prognostic value of TDI in patients with atrial fibrillation. METHODS...

  15. Cardiac time intervals by tissue Doppler imaging M-mode echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor

    2016-01-01

    for myocardial myocytes to achieve an LV pressure equal to that of aorta increases, resulting in a prolongation of the isovolumic contraction time (IVCT). Furthermore, the ability of myocardial myocytes to maintain the LV pressure decreases, resulting in reduction in the ejection time (ET). As LV diastolic...... of whether the LV is suffering from impaired systolic or diastolic function. A novel method of evaluating the cardiac time intervals has recently evolved. Using tissue Doppler imaging (TDI) M-mode through the mitral valve (MV) to estimate the cardiac time intervals may be an improved method reflecting global...

  16. Tissue Doppler Imaging in the evaluation of abdominal aortic pulsatility: a useful tool for the neonatologist.

    Science.gov (United States)

    Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo

    2017-03-01

    Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.

  17. Testing the relativistic Doppler boost hypothesis for supermassive black hole binary candidates

    Science.gov (United States)

    Charisi, Maria; Haiman, Zoltán; Schiminovich, David; D'Orazio, Daniel J.

    2018-06-01

    Supermassive black hole binaries (SMBHBs) should be common in galactic nuclei as a result of frequent galaxy mergers. Recently, a large sample of sub-parsec SMBHB candidates was identified as bright periodically variable quasars in optical surveys. If the observed periodicity corresponds to the redshifted binary orbital period, the inferred orbital velocities are relativistic (v/c ≈ 0.1). The optical and ultraviolet (UV) luminosities are expected to arise from gas bound to the individual BHs, and would be modulated by the relativistic Doppler effect. The optical and UV light curves should vary in tandem with relative amplitudes which depend on the respective spectral slopes. We constructed a control sample of 42 quasars with aperiodic variability, to test whether this Doppler colour signature can be distinguished from intrinsic chromatic variability. We found that the Doppler signature can arise by chance in ˜20 per cent (˜37 per cent) of quasars in the nUV (fUV) band. These probabilities reflect the limited quality of the control sample and represent upper limits on how frequently quasars mimic the Doppler brightness+colour variations. We performed separate tests on the periodic quasar candidates, and found that for the majority, the Doppler boost hypothesis requires an unusually steep UV spectrum or an unexpectedly large BH mass and orbital velocity. We conclude that at most approximately one-third of these periodic candidates can harbor Doppler-modulated SMBHBs.

  18. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...

  19. Detection of magnetic nanoparticles in tissue using magneto-motive ultrasound

    International Nuclear Information System (INIS)

    Oh, Junghwan; Feldman, Marc D; Kim, Jeehyun; Condit, Chris; Emelianov, Stanislav; Milner, Thomas E

    2006-01-01

    The purpose of this study was to demonstrate the magneto-motive ultrasonic detection of superparamagnetic iron oxide (SPIO) nanoparticles as a marker of macrophage recruitment in tissue. The capability of ultrasound to detect SPIO nanoparticles (core diameter ∼20 nm) taken up by murine liver macrophages was investigated. Eight mice were sacrificed two days after the intravenous administration of four SPIO doses (1.5, 1.0, 0.5, and 0.1 mmol Fe/kg body weight). In the iron-laden livers, ultrasound Doppler measurements showed a frequency shift in response to an applied time-varying magnetic field. M-mode scan and colour power Doppler images of the iron-laden livers also demonstrated nanoparticle movement under focused magnetic field excitation. In the livers of two saline injected control mice, no movement was observed using any ultrasound imaging modes. The results of our experiments indicate that ultrasound imaging of magneto-motive excitation is a candidate imaging modality to identify tissue-based macrophages containing SPIO nanoparticles

  20. Interactions between colour-producing mechanisms and their effects on the integumentary colour palette.

    Science.gov (United States)

    Shawkey, Matthew D; D'Alba, Liliana

    2017-07-05

    Animal integumentary coloration plays a crucial role in visual communication and camouflage, and varies extensively among and within species and populations. To understand the pressures underlying such diversity, it is essential to elucidate the mechanisms by which animals have created novel integumentary coloration. Colours can be produced by selective absorption of light by skin pigments, through light scattering by structured or unstructured tissues, or by a combination of pigments and nanostructures. In this review, we highlight our current understanding of the interactions between pigments and structural integumentary tissues and molecules. We analyse the available evidence suggesting that these combined mechanisms are capable of creating colours and optical properties unachievable by either mechanism alone, thereby effectively expanding the animal colour palette. Moreover, structural and pigmentary colour mechanisms frequently interact in unexpected and overlooked ways, suggesting that classification of colours as being of any particular type may be difficult. Finally, we discuss how these mixtures are useful for investigating the largely unknown genetic, developmental and physical processes generating phenotypic diversity.This article is part of the themed issue 'Animal coloration: production, perception, function and application'. © 2017 The Author(s).

  1. Strain ratio ultrasound elastography increases the accuracy of colour-Doppler ultrasound in the evaluation of Thy-3 nodules. A bi-centre university experience.

    Science.gov (United States)

    Cantisani, Vito; Maceroni, Piero; D'Andrea, Vito; Patrizi, Gregorio; Di Segni, Mattia; De Vito, Corrado; Grazhdani, Hektor; Isidori, Andrea M; Giannetta, Elisa; Redler, Adriano; Frattaroli, Fabrizio; Giacomelli, Laura; Di Rocco, Giorgio; Catalano, Carlo; D'Ambrosio, Ferdinando

    2016-05-01

    To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.

  2. Hypercholesterolemia and Myocardial function evaluated via Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Kotaru Pavan

    2009-11-01

    Full Text Available Abstract Objective To establish a link between hypercholesterolemia and myocardial dysfunction. Background Heart failure is a complex disease involving changes in systolic and diastolic function. Newer echocardiographic imaging modalities may be able to detect discreet changes in myocardial function associated with hypercholesterolemia. Therefore we sought to establish a link between hypercholesterolemia and myocardial dysfunction with tissue Doppler imaging (TDI. Methods Twenty-seven rabbits were studied: 7 were fed normal chow (group 1 and 20 a high cholesterol diet (10 with ezetimibe, 1 mg/kg/day; group 2 and 10 without, group 3. Echocardiographic images were obtained under general anesthesia. Serum cholesterol levels were obtained at baseline, 3 and 6 months and myocardial cholesterol levels measured following euthanasia. Results Doppler measurements, including E/A, E'/A' and S' were significantly lower in group 3 compared to both groups 1 and 2 but no significant differences were noted in chamber sizes or ejection fraction among the groups. Average serum cholesterol was higher in group 3 compared to groups 1 and 2 respectively (495 ± 305 mg/dl vs. 114 ± 95 mg/dl and 87 ± 37 mg/dl; p 2 = 0.17 p = 0.04, r2 = 0.37 p = 0.001 and r2 = 0.24 p = 0.01. Conclusion Cholesterol load in the serum and myocardium was significantly associated with decreased systolic and diastolic function by TDI. Moreover, lipid lowering was protective.

  3. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  4. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2011-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  5. Moving Target Detection With Compact Laser Doppler Radar

    Science.gov (United States)

    Sepp, G.; Breining, A.; Eisfeld, W.; Knopp, R.; Lill, E.; Wagner, D.

    1989-12-01

    This paper describes an experimental integrated optronic system for detection and tracking of moving objects. The system is based on a CO2 waveguide laser Doppler ra-dar with homodyne receiver and galvanometer mirror beam scanner. A "hot spot" seeker consisting of a thermal imager with image processor transmits the coordinates of IR-emitting, i.e. potentially powered, objects to the laser radar scanner. The scanner addresses these "hot" locations operating in a large field-of-view (FOV) random ac-cess mode. Hot spots exhibiting a Doppler shifted laser signal are indicated in the thermal image by velocity-to-colour encoded markers. After switching to a small FOV scanning mode, the laser Doppler radar is used to track fast moving objects. Labora-tory and field experiments with moving objects including rotating discs, automobiles and missiles are described.

  6. Tissue Doppler echocardiography reveals distinct patterns of impaired myocardial velocities in different degrees of coronary artery disease

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Mogelvang, Rasmus; Olsen, Niels Thue

    2010-01-01

    Aim To determine how the left ventricular wall motion assessed by echocardiographic Tissue Doppler Imaging (TDI) is affected by increasing severity of coronary artery disease (CAD) among patients with stable angina pectoris and preserved ejection fraction. METHODS AND RESULTS: This study comprise...

  7. Myocardial response to a triathlon in male athletes evaluated by Doppler tissue imaging and biochemical parameters

    DEFF Research Database (Denmark)

    Leetmaa, T H; Dam, A; Glintborg, D

    2008-01-01

    (cTnT) and pro-brain natriuretic peptide (pro-BNP)] and echocardiography. Conventional echocardiography techniques and new Doppler tissue imaging (DTI) modalities were applied before and immediately after the competition. Blood samples were drawn 1 week before, immediately after and 12-24 h post...... and systolic velocities decreased, thus suggesting reversible cardiac fatigue. When using cardiac markers and echocardiographic findings, a triathlon was found to have no significant negative effects on left ventricular function or myocardial tissue in male athletes....

  8. A five-colour colour-coded mapping method for DCE-MRI analysis of head and neck tumours

    International Nuclear Information System (INIS)

    Yuan, J.; Chow, S.K.K.; Yeung, D.K.W.; King, A.D.

    2012-01-01

    Aim: To devise a method to convert the time–intensity curves (TICs) of head and neck dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) data into a pixel-by-pixel colour-coded map for identifying normal tissues and tumours. Materials and methods: Twenty-three patients with head and neck squamous cell carcinoma (HNSCC) underwent DCE-MRI. TIC patterns of primary tumours, metastatic nodes, and normal tissues were assessed and a program was devised to convert the patterns into a classified colour-coded map. The enhancement patterns of tumours and normal tissue structures were evaluated and categorized into nine grades (0–8) based on the predominance of coloured pixels on maps. Results: Five identified TIC patterns were converted into a colour-coded map consisting of red (maximum enhancement), brown (continuous slow rise-up), yellow (rapid wash-in and wash-out), green (rapid wash-in and plateau), and blue (rapid wash-in and rise-up). The colour-coded map distinguished all 21 primary tumours and 15 metastatic nodes from normal structures. Primary tumours and metastatic nodes were colour coded as predominantly yellow (grades 1–2) in 17/21 and 6/15, green (grades 3–5) in 3/21 and 5/15, and blue (grades 6–7) in 1/21 and 4/15, respectively. Vessels were coded red in 46/46 (grade 0) and muscles were coded brown in 23/23 (grade 8). Salivary glands, thyroid glands, and palatine tonsils were coded into predominantly yellow (grade 1) in 46/46 and 10/10 and 18/22, respectively. Conclusion: DCE-MRI derived five-colour-coded mapping provides an objective easy-to-interpret method to assess the dynamic enhancement pattern of head and neck cancers.

  9. Relationship between colour flow Doppler sonographic assessment of corpus luteum activity and progesterone concentrations in mares after embryo transfer.

    Science.gov (United States)

    Brogan, P T; Henning, H; Stout, T A E; de Ruijter-Villani, M

    2016-03-01

    Colour-flow Doppler sonography has been described as a means of assessing corpus luteum (CL) function rapidly, because area of luteal blood vessels correlates well with circulating progesterone (P4) concentrations [P4] in oestrous cycling mares. The aim of this study was to assess the relationships between CL size and vascularity, and circulating [P4] during early pregnancy in mares, and to determine whether luteal blood flow was a useful aid for selecting an embryo transfer recipient. Equine embryos (n=48) were recovered 8 days after ovulation and were transferred to available recipient mares as part of a commercial program with the degree of synchrony in timing of recipient ovulation ranging from 1 day before to 4 days after the donor. Immediately prior to embryo transfer (ET), maximum CL cross-section and blood vessel areas were assessed sonographically, and jugular blood was collected to measure plasma [P4]. Sonographic measurements and jugular blood collection were repeated at day 4 after ET for all mares, and again at days 11, 18 and 25 after ET in mares that were pregnant. The number of grey-scale and colour pixels within the CL was subsequently quantified using ImageJ software. The CL blood flow correlated significantly but weakly with plasma [P4] on the day of transfer and on day 4 after ET in all mares, and on days 11 and 25 after ET in pregnant mares (r=0.30-0.36). The CL area and plasma [P4] were also correlated on each day until day 11 after ET (r=0.49-0.60). The CL colour pixel area decreased significantly after day 18, whereas CL area was already decreasing by day 4 after ET. The CL area, area of blood flow, or [P4] was predictive of pregnancy. Findings in the present study suggest that both CL area and blood flow are correlated with circulating [P4] at the time of transfer and in early pregnancy. Evaluation of the CL using B-mode or CF sonography, although practical, provides no improvement in the selection of recipients or prediction of pregnancy

  10. Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

    International Nuclear Information System (INIS)

    Wardlaw, Joanna M.; Lewis, Steff

    2005-01-01

    Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone

  11. The duplex-Doppler colour echography of the scrotum and testicles in adults and boys. II. the contribution of the urgent study of acute scrotum symptoms; Ecografia duples-Doppler color del escroto y el testiculo en el adulto y el nino. II. Aportacion al estudio urgente del escroto agudo

    Energy Technology Data Exchange (ETDEWEB)

    Rangel-Villalobos, E.; Jimenez-Castellanos, R.; Bustos, C.; Linares, A.; Gonzalez-Prada, F. [Hospital Universitario Virgen Macarena. Sevilla (Spain)

    1999-07-01

    To analyse the findings, contributions and limitations of the Doppler echography for the urgent study of acute scrotum symptoms, both in adults and in boys. 60 patients (22 adults and 38 boys) with acute scrotal symptomatology were examined using B mode echography, followed by a colour duplex-Doppler (CDD) echography with a lineal 7.5 MHz transducer. We compared the findings obtained with those of the healthy contralateral testicle and with surgery or clinical-echographical evolution. The most common pathology was inflammation (27%) followed by ischemic (24%) and traumatic (17%). 12% of the patients had miscellaneous conditions. To conclude, in 20% of the cases the B mode and the Doppler examination was normal, the symptoms were resolved spontaneously. After carrying out the CDD only 14 (23%) of the cases needed immediate surgery and 3 (5%) delayed surgery, the remaining 43 (72%) patients responded to the traditional treatment. The CDD allows for a safe, quick and harmless diagnosis in practically all the acute scrotum cases, for both adults and boys. Its limitations in pre-puberty patients or in cases that were atypical are overcome when put in the hands of an expert radiologist, as they need a longer exploration time and suitable Doppler equipment. The main contribution to the urgent diagnosis of acute scrotum symptoms is that it accurately establishes which patients should be chosen for immediate surgery. (Author) 33 refs.

  12. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Muessig, K. [University Hospital of Duesseldorf (Germany). Dept. of Metabolic Diseases; Leibniz Center for Diabetes Research, Duesseldorf (Germany). Inst. for Clinical Diabetology; University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Schraml, C.; Schwenzer, N.F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology; Rietig, R.; Balletshofer, B. [University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Martirosian, P.; Haering, H.U.; Schick, F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; Claussen, C.D. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology

    2012-12-15

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  13. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    2016-01-01

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  14. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  15. Influence of recent exercise and skin temperature on ultrasound Doppler measurements in patients with rheumatoid arthritis--an intervention study

    DEFF Research Database (Denmark)

    Ellegaard, Karen; Torp-Pedersen, Søren; Henriksen, Marius

    2009-01-01

    activity. It is unclear, however, whether the hyperaemia alone reflects the disease activity or may be influenced by other factors. METHODS: Twenty-nine patients with RA underwent USD examination of the wrist before and immediately after three interventions. The interventions were carried out on three...... separate days. The interventions were (i) isometric exercise of the muscles of the hand and forearm, (ii) heating and (iii) cooling of the hand. The amount of Doppler in the wrist joint was quantified by measuring the percentage of colour in the synovium-the colour fraction (CF). The CF values estimated...... the amount of Doppler activity might be affected by low skin temperatures....

  16. A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    International Nuclear Information System (INIS)

    Kastrup, J.; Buelow, J.; Lassen, N.A.

    1987-01-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by 133 Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vaso-constrictor reflex by lowering the area of investigation below heart level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and 133 Xenon blood flow measurements were performed simultaneously on the sympathetically denervated forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The 133 Xenon method recorded a 44% decrease in blood flow in innervated and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and 133 Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes. (author)

  17. Comparison between /sup 133/Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    Energy Technology Data Exchange (ETDEWEB)

    Kastrup, J.; Buelow, J.; Lassen, N.A.

    1987-10-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by /sup 133/Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vaso-constrictor reflex by lowering the area of investigation below heart level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and /sup 133/Xenon blood flow measurements were performed simultaneously on the sympathetically denervated forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The /sup 133/Xenon method recorded a 44% decrease in blood flow in innervated and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and /sup 133/Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes.

  18. Evaluation of arterial embolization in treating hyperthyroidism by colour ultrasonography

    International Nuclear Information System (INIS)

    Sun Xiuying; Yang Jijin; Chen Ningning; Gu Limin; Wang Ying; Chen Jianquan

    2003-01-01

    Objective: To assess the effect of arterial embolization in treating hyperthyroidism by colour ultrasonography. Methods: Forty two cases of hyperthyroidism were treated with thyroid-arteries embolization. A few days before and 1, 3, 6 months after embolization, the echograms of thyroids were observed including the volumes of thyroids and the internal diameters of thyroid-arteries were measured with colour ultrasonography respectively. The Vs, Vd, Vm, PI, RI were measured with the Doppler and the quantities of blood flow were calculated. The relationships of changes for all these parameters and T 3 , T 4 and TSH were analysed. Results: Before artery embolization all thyroids were enlarged with diffusely homogenous or heterogenous low-echoes and nodules in some patients accompanied by widening of the thyroid arteries and their branches full of blood supply. The volume of thyroids decreased after artery embolization. 1-3 months later the echo of thyroids enhanced and got coarse with decrease of the thyroid vasculature and narrowing of vessel calibers except a few star- or stop-like blood streams were sometimes seen within the thyroids and no blood flow signals found in some cases. 3-6 months after embolization, the echo of thyroids decreased gradually or unevenly distributed. All the parameters of blood flow before and after the treatment showed statistically significant differences (P < 0.05). Conclusions: Embolization of thyroid arteries is a relatively new and effective technique in treating hyperthyroidism. Colour Doppler ultrasonography plays an important role for correct diagnosis and prognostication

  19. Effects of memory colour on colour constancy for unknown coloured objects.

    Science.gov (United States)

    Granzier, Jeroen J M; Gegenfurtner, Karl R

    2012-01-01

    The perception of an object's colour remains constant despite large variations in the chromaticity of the illumination-colour constancy. Hering suggested that memory colours, the typical colours of objects, could help in estimating the illuminant's colour and therefore be an important factor in establishing colour constancy. Here we test whether the presence of objects with diagnostical colours (fruits, vegetables, etc) within a scene influence colour constancy for unknown coloured objects in the scene. Subjects matched one of four Munsell papers placed in a scene illuminated under either a reddish or a greenish lamp with the Munsell book of colour illuminated by a neutral lamp. The Munsell papers were embedded in four different scenes-one scene containing diagnostically coloured objects, one scene containing incongruent coloured objects, a third scene with geometrical objects of the same colour as the diagnostically coloured objects, and one scene containing non-diagnostically coloured objects (eg, a yellow coffee mug). All objects were placed against a black background. Colour constancy was on average significantly higher for the scene containing the diagnostically coloured objects compared with the other scenes tested. We conclude that the colours of familiar objects help in obtaining colour constancy for unknown objects.

  20. Mechanical Dyssynchrony by Tissue Doppler Cross-Correlation is Associated with Risk for Complex Ventricular Arrhythmias after Cardiac Resynchronization Therapy

    DEFF Research Database (Denmark)

    Tayal, Bhupendar; Gorcsan, John; Delgado-Montero, Antonia

    2015-01-01

    BACKGROUND: Tissue Doppler cross-correlation analysis has been shown to be associated with long-term survival after cardiac resynchronization defibrillator therapy (CRT-D). Its association with ventricular arrhythmia (VA) is unknown. METHODS: From two centers 151 CRT-D patients (New York Heart...... Association functional classes II-IV, ejection fraction ≤ 35%, and QRS duration ≥ 120 msec) were prospectively included. Tissue Doppler cross-correlation analysis of myocardial acceleration curves from the basal segments in the apical views both at baseline and 6 months after CRT-D implantation was performed...... with a substantially increased risk for VA (hazard ratio [HR], 4.4; 95% CI, 1.2-16.3; P = .03) and VA or death (HR, 4.0; 95% CI, 1.7-9.6; P = .002) after adjusting for other covariates. Similarly, patients with new dyssynchrony had increased risk for VA (HR, 10.6; 95% CI, 2.8-40.4; P = .001) and VA or death (HR, 5...

  1. Effects of Memory Colour on Colour Constancy for Unknown Coloured Objects

    Directory of Open Access Journals (Sweden)

    Jeroen J M Granzier

    2012-04-01

    Full Text Available The perception of an object's colour remains constant despite large variations in the chromaticity of the illumination—colour constancy. Hering suggested that memory colours, the typical colours of objects, could help in estimating the illuminant's colour and therefore be an important factor in establishing colour constancy. Here we test whether the presence of objects with diagnostical colours (fruits, vegetables, etc within a scene influence colour constancy for unknown coloured objects in the scene. Subjects matched one of four Munsell papers placed in a scene illuminated under either a reddish or a greenish lamp with the Munsell book of colour illuminated by a neutral lamp. The Munsell papers were embedded in four different scenes—one scene containing diagnostically coloured objects, one scene containing incongruent coloured objects, a third scene with geometrical objects of the same colour as the diagnostically coloured objects, and one scene containing non-diagnostically coloured objects (eg, a yellow coffee mug. All objects were placed against a black background. Colour constancy was on average significantly higher for the scene containing the diagnostically coloured objects compared with the other scenes tested. We conclude that the colours of familiar objects help in obtaining colour constancy for unknown objects.

  2. Effects of memory colour on colour constancy for unknown coloured objects

    OpenAIRE

    Granzier, Jeroen J M; Gegenfurtner, Karl R

    2012-01-01

    The perception of an object's colour remains constant despite large variations in the chromaticity of the illumination—colour constancy. Hering suggested that memory colours, the typical colours of objects, could help in estimating the illuminant's colour and therefore be an important factor in establishing colour constancy. Here we test whether the presence of objects with diagnostical colours (fruits, vegetables, etc) within a scene influence colour constancy for unknown coloured objects in...

  3. Assessing the usefulness of B-mode and colour Doppler sonography, and measurements of circulating progesterone concentrations for determining ovarian responses in superovulated ewes.

    Science.gov (United States)

    Oliveira, Mef; Ribeiro, I F; Rodriguez, Mgk; Maciel, G S; Fonseca, J F; Brandão, F Z; Bartlewski, P M

    2018-06-01

    The main goal of this study was to assess the usefulness of two imaging modalities, namely the B-mode and colour Doppler sonography, and serum progesterone (P 4 ) concentrations for determining the ovarian response in superovulated ewes. Twenty-four sexually mature Santa Inês ewes underwent the superovulatory treatment consisting of eight injections of porcine FSH (total dose of 200 or 133 or 100 mg; n = 8 ewes/total dose) given at 12-hr intervals and initiated 48 hr before CIDR ® (Pfizer Inc., Auckland, New Zealand) removal. Six days after natural mating, the ovaries of all donor ewes were visualized and examined with transrectal ultrasonography and then with videolaparoscopy to identify and enumerate corpora lutea (CL) and luteinized unovulated follicles (LUFs). Jugular blood samples were collected just prior to ovarian examinations. The total number of CL (r = .78 and 0.83, p ewes. © 2018 Blackwell Verlag GmbH.

  4. Colour Doppler Ultrasonography as a Tool to Assess Luteal Function in Santa Inês Ewes.

    Science.gov (United States)

    Figueira, L M; Fonseca, J F; Arashiro, Ekn; Souza-Fabjan, Jmg; Ribeiro, Acs; Oba, E; Viana, Jhm; Brandão, F Z

    2015-08-01

    The aim of this study was to evaluate luteal dynamics in the Santa Inês ewes using colour Doppler (CD) ultrasonography. Oestrus was synchronized in nulliparous females (n = 18), and subsequently, they were only teased (n = 6) or teased and mated (n = 12). Blood samples were collected daily for plasma progesterone (P4 ) concentrations. Ultrasonographic images of corpora lutea (CL) in CD mode were obtained for further analysis in its largest diameter. The CD mode allowed an early sequential monitoring of CL that was visualized by the first time 0.77 ± 0.62 days after ovulation, with luteal area 29.68 ± 13.21 mm(2) . During the luteogenesis, a progressive increase was observed, followed by a plateau of luteal area, vascularization area and plasma concentrations of P4 reaching maximum values in D11 (124.0 ± 38.0 mm(2) , 52.78 ± 24.08 mm(2) and 11.23 ± 4.89 ng/ml, respectively). In the luteolysis, the plasma concentrations of P4 decreased sharply, whereas luteal and vascularization area gradually. The vascularization area was positively correlated with plasma concentrations of P4 during the luteogenesis (r = 0.22) and luteolysis (r = 0.48). The luteal dynamics of Santa Inês ewes showed patterns similar to those observed in other sheep breeds studied. The CD ultrasonography has the potential to be used as a tool to assess luteal function in sheep. © 2015 Blackwell Verlag GmbH.

  5. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  6. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Pulmonary regurgitation (PR) following repair of right ventricular (RV) outflow obstruction is related to slowly progressive RV dilatation and heart failure and will eventually require surgical intervention, but optimal timing of pulmonary valve replacement is challenging. Tissue Doppler based...

  7. Evaluation of Pulsed Doppler-Versus Tissue Doppler-Derived Tei Index of Right and Left Ventricle in Fetuses

    Directory of Open Access Journals (Sweden)

    Hamid Amoozgar

    2011-12-01

    Full Text Available Background: The myocardial performance index (MPI, also known as the Tei index, was introduced by Tei et al. to evaluate cardiac function in adults with dilated cardiomyopathy. This index is defined as the sum of isovolumic contraction time (ICT and isovolumic relaxation time (IRT, divided by ejection time (ET. Objectives: To determine the correlation between pulsed Doppler (PD- and tissue Doppler imaging (TDI-derived Tei indices in fetuses. Patients and Methods: Right and left ventricle PD and TDI echocardiographic data were obtained from 59 fetuses (11 pregnant women who were positive for anti-SSA-Ro or anti-SSB-La antibodies, 18 women who were referred due to dysrhythmia, and 30 women who had normal clinical findings. Results: Mean fetal gestational age was 27 ± 6.4 weeks. Mean PD Tei index of the mitral and tricuspid valve was 0.58 ± 0.05 and 0.53 ± 0.08, respectively. Mean TDI indices for the mitral and tricuspid valve were 0.56 ± 0.09 and 0.55 ± 0.08, respectively. There were no significant differences between mitral and tricuspid PD- and TDI-derived Tei indices (P = 0.87, P= 0.21, but the Bland-Altman diagrams showed no fine agreement between the indices (the mean difference ± 1 standard deviation of the right ventricular PD- and TDI-derived Tei indices was 0.24 ± 0.02 and 0.29 ± 0.04 for the left ventricle. There were no significant differences in PD- and TDI-derived Tei indexes between groups of evaluated fetuses (Mitral valve: PD-Tei P=0.69, TDI-Tei P=0.49; Tricuspid valve: PD-Tei P=0.41, TDI-Tei P=0.36. Conclusions: Although the mean values of the two indices did not differ significantly, the TDI-derived and PD-derived Tei indices did not have fine agreement.

  8. Colour application on mammography image segmentation

    Science.gov (United States)

    Embong, R.; Aziz, N. M. Nik Ab.; Karim, A. H. Abd; Ibrahim, M. R.

    2017-09-01

    The segmentation process is one of the most important steps in image processing and computer vision since it is vital in the initial stage of image analysis. Segmentation of medical images involves complex structures and it requires precise segmentation result which is necessary for clinical diagnosis such as the detection of tumour, oedema, and necrotic tissues. Since mammography images are grayscale, researchers are looking at the effect of colour in the segmentation process of medical images. Colour is known to play a significant role in the perception of object boundaries in non-medical colour images. Processing colour images require handling more data, hence providing a richer description of objects in the scene. Colour images contain ten percent (10%) additional edge information as compared to their grayscale counterparts. Nevertheless, edge detection in colour image is more challenging than grayscale image as colour space is considered as a vector space. In this study, we implemented red, green, yellow, and blue colour maps to grayscale mammography images with the purpose of testing the effect of colours on the segmentation of abnormality regions in the mammography images. We applied the segmentation process using the Fuzzy C-means algorithm and evaluated the percentage of average relative error of area for each colour type. The results showed that all segmentation with the colour map can be done successfully even for blurred and noisy images. Also the size of the area of the abnormality region is reduced when compare to the segmentation area without the colour map. The green colour map segmentation produced the smallest percentage of average relative error (10.009%) while yellow colour map segmentation gave the largest percentage of relative error (11.367%).

  9. Prognostic Value of Cardiac Time Intervals by Tissue Doppler Imaging M-Mode in Patients With Acute ST-Segment-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Søgaard, Peter

    2013-01-01

    Background- Color tissue Doppler imaging M-mode through the mitral leaflet is an easy and precise method to estimate all cardiac time intervals from 1 cardiac cycle and thereby obtain the myocardial performance index (MPI). However, the prognostic value of the cardiac time intervals and the MPI...... assessed by color tissue Doppler imaging M-mode through the mitral leaflet in patients with ST-segment-elevation myocardial infarction (MI) is unknown. Methods and Results- In total, 391 patients were admitted with an ST-segment-elevation MI, treated with primary percutaneous coronary intervention...

  10. Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy

    NARCIS (Netherlands)

    O.I.I. Soliman (Osama Ibrahim Ibrahim); D.A.M.J. Theuns (Dominic); M.L. Geleijnse (Marcel); A. Nemes (Attila); K. Caliskan (Kadir); W.B. Vletter (Wim); L.J.L.M. Jordaens (Luc); F.J. ten Cate (Folkert)

    2007-01-01

    textabstractAims: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) ≥60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). Methods and results

  11. Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Ruefenacht, D; Delpy, D T

    2006-01-01

    Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware

  12. Mechanical dyssynchrony evaluated by tissue Doppler cross-correlation analysis is associated with long-term survival in patients after cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Risum, Niels; Williams, Eric S; Khouri, Michel G

    2013-01-01

    Aims Pre-implant assessment of longitudinal mechanical dyssynchrony using cross-correlation analysis (XCA) was tested for association with long-term survival and compared with other tissue Doppler imaging (TDI)-derived indices. Methods and results In 131 patients referred for cardiac resynchroniz......Aims Pre-implant assessment of longitudinal mechanical dyssynchrony using cross-correlation analysis (XCA) was tested for association with long-term survival and compared with other tissue Doppler imaging (TDI)-derived indices. Methods and results In 131 patients referred for cardiac......-max was independently associated with improved survival when adjusted for QRS > 150 ms and aetiology {hazard ratio (HR) 0.35 [95% confidence interval (CI) 0.16-0.77], P = 0.01}. Maximal activation delay performed significantly better than Yu index, OWD, and the presence of left bundle branch block (P ..., for difference between parameters). In subgroup analysis, patients without dyssynchrony and QRS between 120 and 150 ms showed a particularly poor survival [HR 4.3 (95% CI 1.46-12.59), P

  13. Memory colours affect colour appearance.

    Science.gov (United States)

    Witzel, Christoph; Olkkonen, Maria; Gegenfurtner, Karl R

    2016-01-01

    Memory colour effects show that colour perception is affected by memory and prior knowledge and hence by cognition. None of Firestone & Scholl's (F&S's) potential pitfalls apply to our work on memory colours. We present a Bayesian model of colour appearance to illustrate that an interaction between perception and memory is plausible from the perspective of vision science.

  14. Soft tissue thickness values for black and coloured South African children aged 6-13 years.

    Science.gov (United States)

    Briers, N; Briers, T M; Becker, P J; Steyn, M

    2015-07-01

    In children, craniofacial changes due to facial growth complicate facial approximations and require specific knowledge of soft tissue thicknesses (STT). The lack of South African juvenile STT standards of particular age groups, sex and ancestry is problematic. According to forensic artists in the South African Police Service the use of African-American values to reconstruct faces of Black South African children yields poor results. In order to perform a facial approximation that presents a true reflection of the child in question, information regarding differences in facial soft tissue at different ages, sexes and ancestry groups is needed. The aims of this study were to provide data on STT of South African Black and Coloured children and to assess differences in STT with respect to age, sex and ancestry. STT was measured using cephalograms of South African children (n=388), aged 6-13 years. After digitizing the images, STT measurements were taken at ten mid-facial landmarks from each image using the iTEM measuring program. STT comparisons between groups per age, sex and ancestry were statistically analyzed. The results showed that STT differences at lower face landmarks are more pronounced in age groups per ancestry as opposed to differences per age and sex. Generally, an increase in STT was seen between 6-10 year old groups and 11-13 year old groups, regardless of ancestry and sex, at the midphiltrum, labiale inferius, pogonion, and beneath chin landmarks. This research created a reference dataset for STT of South African children of Black and Coloured ancestry per age and sex that will be useful for facial reconstruction/approximation of juvenile remains. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Study of the Myocardial Contraction and Relaxation Velocities through Doppler Tissue Imaging Echocardiography: A New Alternative in the Assessment of the Segmental Ventricular Function

    Directory of Open Access Journals (Sweden)

    Silva Carlos Eduardo Suaide

    2002-01-01

    Full Text Available OBJECTIVE: Doppler tissue imaging (DTI enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male with ages ranging from 12 to 59 years (32.9 ± 10.6. Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls were respectively, in cm/s, 7.35(1.64, 5.26(1.88, and 3.33(1.58 in systole and 10.56(2.34, 7.92(2.37, and 3.98(1.64 in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms, and diastolic was 459.18ms (±18.13ms based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05. The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.

  16. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  17. Utilization of laser Doppler flowmetry and tissue spectrophotometry for burn depth assessment using a miniature swine model.

    Science.gov (United States)

    Lotter, Oliver; Held, Manuel; Schiefer, Jennifer; Werner, Ole; Medved, Fabian; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Jaminet, Patrick; Rothenberger, Jens

    2015-01-01

    Currently, the diagnosis of burn depth is primarily based on a visual assessment and can be dependent on the surgeons' experience. The goal of this study was to determine the ability of laser Doppler flowmeter combined with a tissue spectrophotometer to discriminate burn depth in a miniature swine burn model. Burn injuries of varying depth, including superficial-partial, deep-partial, and full thickness, were created in seven Göttingen minipigs using an aluminium bar (100 °C), which was applied to the abdominal skin for periods of 1, 3, 6, 12, 30, and 60 seconds with gravity alone. The depth of injury was evaluated histologically using hematoxylin and eosin staining. All burns were assessed 3 hours after injury using a device that combines a laser light and a white light to determine blood flow, hemoglobin oxygenation, and relative amount of hemoglobin. The blood flow (41 vs. 124 arbitrary units [AU]) and relative amount of hemoglobin (32 vs. 52 AU) were significantly lower in full thickness compared with superficial-partial thickness burns. However, no significant differences in hemoglobin oxygenation were observed between these depths of burns (61 vs. 60%). These results show the ability of laser Doppler flowmeter and tissue spectrophotometer in combination to discriminate between various depths of injury in the minipig model, suggesting that this device may offer a valuable tool for burn depth assessment influencing burn management. © 2014 by the Wound Healing Society.

  18. Variações de parâmetros da função diastólica do ventrículo esquerdo de acordo com a idade através da ecocardiografia com Doppler tissular Changes in the parameters of left ventricular diastolic function according to age on tissue Doppler imaging

    Directory of Open Access Journals (Sweden)

    Márcia Duarte Pedone

    2004-12-01

    Full Text Available OBJETIVO: Determinar a correlação entre as velocidades diastólicas do Doppler tissular com a idade em amostra de adultos saudáveis, e correlacionar a idade com as velocidades do fluxo transmitral e de veias pulmonares. MÉTODOS: Estudados, através da ecocardiografia, 51 indivíduos saudáveis, com idades entre 21 e 69 anos e registradas as velocidades miocárdicas diastólicas ao Doppler tissular e determinadas as velocidades dos fluxos transmitral e venoso pulmonar. RESULTADOS: As velocidades miocárdicas diastólicas iniciais septal basal e lateral basal apresentaram correlação inversa com a idade, com r = - 0,40 (p = 0,004 e r = - 0,60 (p = 0,0001 respectivamente. As velocidades atriogênicas do Doppler tissular foram diretamente correlacionadas com a idade, sendo no segmento septal basal r = 0,56 (p = 0,0001 e no segmento lateral basal r = 0,50 (p = 0,0001. As velocidades do fluxo transmitral e do fluxo venoso pulmonar também mostraram correlação com a idade. CONCLUSÃO: Existe correlação entre a idade e as velocidades miocárdicas diastólicas do Doppler tissular e com as velocidades do fluxo transmitral e fluxo venoso pulmonar, demonstrando em indivíduos saudáveis uma variação de parâmetros da função diastólica do ventrículo esquerdo com a evolução natural da idade.OBJECTIVE: To determine the correlation between diastolic velocities on tissue Doppler imaging and age in a sample of healthy adults and to correlate age with the velocities of transmitral and pulmonary vein flows. METHODS: Echocardiographic assessment of 51 healthy individuals, whose ages ranged from 21 to 69 years. The diastolic myocardial velocities were recorded on tissue Doppler imaging. The velocities of the transmitral and pulmonary vein flows were also determined. RESULTS: The initial basal septal and basal lateral diastolic myocardial velocities showed an inverse correlation with age [r = - 0.40 (P = 0.004, and r = - 0.60 (P = 0.0001, respectively

  19. Quantitation of stress echocardiography by tissue Doppler and strain rate imaging: a dream come true?

    Science.gov (United States)

    Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola

    2005-01-01

    Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

  20. The association between brain natriuretic peptide and tissue Doppler parameters in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Taliha Öner

    2016-01-01

    Full Text Available In this study, we investigated the association between brain natriuretic peptide (BNP levels and tissue Doppler imaging measurements and also screening for deadly mutations in patients with hypertrophic cardiomyopathy (HCM. We enrolled 20 patients diagnosed with HCM (age:10.7±5 years (1-17, 85% male, weight:42.25±23.10 kg, height:141.80±32.45 cm and 20 age, gender and body weight-matched control subjects. We performed electrocardiography, transthoracic echocardiography, and tissue Doppler echocardiography in each group, as well as genetic tests (for Arg403Gln, Arg453Cys, Arg719Trp and Arg719Gln mutations in MYH7 Exons 13, 14, 19 and BNP in the patients. The patients were divided into two groups according to the presence (Group 1 or absence (Group 2 of left ventricular (LV outflow tract obstruction. QTc dispersion and the LV ejection fraction and left atrial (LA volume index were increased in Group 1. The LA volume index and the mitral and septal E/Ea ratio and septum Z-score were increased while the mitral lateral annulus and septal annulus Ea wave velocities and the mitral and tricuspid E/A ratio were decreased in patients with high levels of BNP compared to those with normal BNP levels. There were no mutations that are associated with increased risk of sudden death found in patients included in this study. In the light of our data, we conclude that such parameters BNP levels above the 98 pg/mL, septal thickness Z-score ˃6, and higher mitral and septal E/Ea ratios can be used for management of patients with HCM according to life-threatening conditions.

  1. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness

    Science.gov (United States)

    Forder, Lewis; Taylor, Olivia; Mankin, Helen; Scott, Ryan B.; Franklin, Anna

    2016-01-01

    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d’) and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object’s stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain. PMID:27023274

  2. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness.

    Science.gov (United States)

    Forder, Lewis; Taylor, Olivia; Mankin, Helen; Scott, Ryan B; Franklin, Anna

    2016-01-01

    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d') and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object's stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain.

  3. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness.

    Directory of Open Access Journals (Sweden)

    Lewis Forder

    Full Text Available The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry, detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d' and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object's stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain.

  4. Hue-specific colour memory impairment in an individual with intact colour perception and colour naming.

    Science.gov (United States)

    Jakobson, L S; Pearson, P M; Robertson, B

    2008-01-15

    Cases of hue-selective dyschomatopsias, together with the results of recent optical imaging studies [Xiao, Y., Casti, A. R. R., Xiao, J., & Kaplan, E. (2006). A spatially organized representation of colour in macaque primary visual cortex. Perception, 35, ECVP Abstract Supplement; Xiao, Y., Wang, Y., & Felleman, D. J. (2003). A spatially organized representation of colour in macaque cortical area V2. Nature, 421, 535-539], have provided support for the idea that different colours are processed in spatially distinct regions of extrastriate cortex. In the present report, we provide evidence suggesting that a similar, but distinct, map may exist for representations of colour in memory. This evidence comes from observations of a young woman (QP) who demonstrates an isolated deficit in colour memory secondary to a concussive episode. Despite having normal colour perception and colour naming skills, and above-average memory skills in other domains, QP's ability to recall visually encoded colour information over short retention intervals is dramatically impaired. Her long-term memory for colour and her colour imagery skills are also abnormal. Surprisingly, however, these impairments are not seen with all hues; specifically, her ability to remember or imagine blue shades is spared. This interesting case contributes to the literature suggesting that colour perception, naming, and memory can be clinically dissociated, and provides insights into the organization of colour information in memory.

  5. A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    DEFF Research Database (Denmark)

    Kastrup, J; Bülow, J; Lassen, N A

    1987-01-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by 133Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vasoconstrictor reflex by lowering the area of investigation below heart...... forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The 133Xenon method recorded a 44% decrease in blood flow in innervated...... level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and 133Xenon blood flow measurements were performed simultaneously on the sympathetically denervated...

  6. Colour in flux: describing and printing colour in art

    Science.gov (United States)

    Parraman, Carinna

    2008-01-01

    This presentation will describe artists, practitioners and scientists, who were interested in developing a deeper psychological, emotional and practical understanding of the human visual system who were working with wavelength, paint and other materials. From a selection of prints at The Prints and Drawings Department at Tate London, the presentation will refer to artists who were motivated by issues relating to how colour pigment was mixed and printed, to interrogate and explain colour perception and colour science, and in art, how artists have used colour to challenge the viewer and how a viewer might describe their experience of colour. The title Colour in Flux refers, not only to the perceptual effect of the juxtaposition of one colour pigment with another, but also to the changes and challenges for the print industry. In the light of screenprinted examples from the 60s and 70s, the presentation will discuss 21 st century ideas on colour and how these notions have informed the Centre for Fine Print Research's (CFPR) practical research in colour printing. The latter part of this presentation will discuss the implications for the need to change methods in mixing inks that moves away from existing colour spaces, from non intuitive colour mixing to bespoke ink sets, colour mixing approaches and colour mixing methods that are not reliant on RGB or CMYK.

  7. Specifying colours for colour vision testing using computer graphics.

    Science.gov (United States)

    Toufeeq, A

    2004-10-01

    This paper describes a novel test of colour vision using a standard personal computer, which is simple and reliable to perform. Twenty healthy individuals with normal colour vision and 10 healthy individuals with a red/green colour defect were tested binocularly at 13 selected points in the CIE (Commission International d'Eclairage, 1931) chromaticity triangle, representing the gamut of a computer monitor, where the x, y coordinates of the primary colour phosphors were known. The mean results from individuals with normal colour vision were compared to those with defective colour vision. Of the 13 points tested, five demonstrated consistently high sensitivity in detecting colour defects. The test may provide a convenient method for classifying colour vision abnormalities.

  8. Colour discrimination of dental professionals and colour deficient laypersons.

    Science.gov (United States)

    Poljak-Guberina, Renata; Celebic, Asja; Powers, John M; Paravina, Rade D

    2011-12-01

    The aim of the present study was to compare results of non-dental (conventional) and dental colour discrimination tests (customized, shade guide test), to evaluate influence of profession, gender and age of colour normal dentists and laboratory technicians on colour discrimination results and to evaluate results of colour deficient laypersons. A total of 36 colour normal dental professionals, all volunteers were divided into two groups consisting of 18 participants each: dentists (DDS) and laboratory technicians (CDT). In addition, a group 15 colour deficient males also volunteered (CDP). Colour discrimination was examined using Farnsworth-Munsell 100 Hue Test and total error scores (TES) were calculated. Participants performed a dentistry related colour discrimination test by matching 26 pairs of shade tabs. Shade guide scores (3DS) were calculated. These tests were performed under the controlled conditions of a viewing booth. Mean values and standard deviations were determined. ANOVA, Mann-Whitney test, t-test and Pearson's correlation coefficient (r) were used for result analysis. TES and 3DS were correlated for colour normal observers, r = 0.47 (p gender and age were recorded. TES of 159 (83) and 3DS of 6.7 (2.7) were recorded for colour deficient laypersons. Based on TES, 33% of colour deficient laypersons had average discrimination, whilst 67% had low discrimination. Within the limitation of this study, it was concluded that results of non-dental and dental colour discrimination tests were correlated, and that profession (DDS/CDT), gender and age gender did not influence colour discrimination of colour normal participants. Although colour and appearance of dental restorations are of paramount importance for the aesthetic outcome, colour vision of dental professionals is not routinely tested. This paper validates and recommends the usage of dental shade guides for a simple, affordable and understandable testing of colour vision, either as a sole test or

  9. Colour simplicity

    OpenAIRE

    du Preez, Warren

    2017-01-01

    This dissertation addresses the metaphysics of conscious experience. I defend a thesis labelled Colour Simplicity, according to which the properties constitutive of what it is like to have visual sensory experiences of colourcolour qualia – are simple, in that they lack more basic constituent properties. I develop a valid argument for Colour Simplicity, drawing on the premises that (P1) ‘colour qualia appear to be simple under introspection’, and (P2) ‘if colour qualia appear to be simp...

  10. Daylight Influence on Colour Design : Empirical Study on Perceived Colour and Colour Experience Indoors

    OpenAIRE

    Hårleman, Maud

    2007-01-01

    It is known that one and the same interior colouring will appear different in rooms with windows facing north or facing south, but it is not known how natural daylight from these two compass points affects perceived colour and the ways in which colour is experienced. The objective is to describe the perceived colours to be expected in rooms with sunlight and diffused light, and thus develop a tool for colour design. Two empirical investigations provide the basis for six attached papers. The m...

  11. Does Colour Preference Have a Role in Colour Term Acquisition?

    Science.gov (United States)

    Pitchford, Nicola J.; Davis, Emma E.; Scerif, Gaia

    2009-01-01

    A developmental association exists between colour preference and emerging colour term acquisition in young children. Colour preference might influence colour term acquisition by directing attention towards or away from a particular colour, making it more or less memorable. To investigate the role that colour preference may have in the acquisition…

  12. Colours sometimes count: awareness and bidirectionality in grapheme-colour synaesthesia.

    Science.gov (United States)

    Johnson, Addie; Jepma, Marieke; de Jong, Ritske

    2007-10-01

    Three experiments were conducted with 10 grapheme-colour synaesthetes and 10 matched controls to investigate (a) whether awareness of the inducer grapheme is necessary for synaesthetic colour induction and (b) whether grapheme-colour synaesthesia may be bidirectional in the sense that not only do graphemes induce colours, but that colours influence the processing of graphemes. Using attentional blink and Stroop paradigms with digit targets, we found that some synaesthetes did report "seeing" synaesthetic colours even when they were not able to report the inducing digit. Moreover, congruency effects (effects of matching the colour of digit presentation with the synaesthetic colour associated with that digit) suggested that grapheme-colour synaesthesia can be bidirectional, at least for some synaesthetes.

  13. Colour scheme an exploration of the indeterminate space of colour

    OpenAIRE

    Varga, Tania Elke

    2017-01-01

    Colour Scheme examines the potential for colour to be understood as a relational and therefore, indeterminate space. The CMYK process colour model is reworked to investigate the idea of colour as an indeterminate space. In proposing that process colour can be understood as a fluid and relational system I draw attention to the unquantifiable and qualitative nature of colour. Colour can be understood as a verb, and as such may be thought of as an active substance. This understanding of col...

  14. Validation of a colour rendering index based on memory colours

    OpenAIRE

    Smet, Kevin; Jost-Boissard, Sophie; Ryckaert, Wouter; Deconinck, Geert; Hanselaer, Peter

    2010-01-01

    In this paper the performance of a colour rendering index based on memory colours is investigated in comparison with the current CIE Colour Rendering Index, the NIST Colour Quality Scale and visual appreciation results obtained at CNRS at Lyon University for a set of 3000K and 4000K LED light sources. The Pearson and Spearman correlation coefficients between each colour rendering metric and the two sets of visual results were calculated. It was found that the memory colour based colour render...

  15. Colour thresholding and objective quantification in bioimaging

    Science.gov (United States)

    Fermin, C. D.; Gerber, M. A.; Torre-Bueno, J. R.

    1992-01-01

    Computer imaging is rapidly becoming an indispensable tool for the quantification of variables in research and medicine. Whilst its use in medicine has largely been limited to qualitative observations, imaging in applied basic sciences, medical research and biotechnology demands objective quantification of the variables in question. In black and white densitometry (0-256 levels of intensity) the separation of subtle differences between closely related hues from stains is sometimes very difficult. True-colour and real-time video microscopy analysis offer choices not previously available with monochrome systems. In this paper we demonstrate the usefulness of colour thresholding, which has so far proven indispensable for proper objective quantification of the products of histochemical reactions and/or subtle differences in tissue and cells. In addition, we provide interested, but untrained readers with basic information that may assist decisions regarding the most suitable set-up for a project under consideration. Data from projects in progress at Tulane are shown to illustrate the advantage of colour thresholding over monochrome densitometry and for objective quantification of subtle colour differences between experimental and control samples.

  16. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  17. Physiological effects of some synthetic food colouring additives on rats.

    Science.gov (United States)

    Aboel-Zahab, H; el-Khyat, Z; Sidhom, G; Awadallah, R; Abdel-al, W; Mahdy, K

    1997-11-01

    Three different synthetic chocolate colourant agents (A, B and C) were administered to healthy adult male albino rats for 30 and 60 day periods to evaluate their effects on body weight, blood picture, liver and kidney functions, blood glucose, serum and liver lipids, liver nucleic acids (DNA and RNA), thyroid hormones (T3 and T4) and growth hormone. In addition, histopathological examinations of liver, kidney and stomach sections were studied. These parameters were also investigated 30 days after colourant stoppage (post effect). Ingestion of colourant C (brown HT and indigocarmine) significantly decreased rat body weight, serum cholesterol and HDL-cholesterol fraction, while, T4 hormone, liver RNA content, liver enzymes (S. GOT, S. GPT and alkaline phosphatase), total protein and globulin fractions were significantly elevated. Significant increases were observed in serum total lipids, cholesterol, triglycerides, total protein, globulin and serum transaminases in rats whose diets were supplemented with chocolate colours A and B (sunset yellow, tartrazine, carmoisine and brilliant blue in varying concentrations). Haematological investigations demonstrated selective neutropenia and lymphocytosis with no significant alterations of total white blood cell counts in all rat groups, while haemoglobin concentrations and red blood cell counts were significantly decreased in the rats who were administered food additives A and B. Eosinophilia was noted in rats fed on colourant A only. No changes were recorded for blood glucose, growth hormone and kidney function tests. Histopathological studies showed brown pigment deposition in the portal tracts and Van Küpffer cells of the liver as well as in the interstitial tissue and renal tubular cells of the kidney mainly induced by colourant A. Congested blood vessels and areas of haemorrhage in both liver and renal sections were revealed in those rats who were given colourants B and C. There were no-untoward-effects recorded in the

  18. Rethinking Colour Constancy.

    Directory of Open Access Journals (Sweden)

    Alexander D Logvinenko

    Full Text Available Colour constancy needs to be reconsidered in light of the limits imposed by metamer mismatching. Metamer mismatching refers to the fact that two objects reflecting metameric light under one illumination may reflect non-metameric light under a second; so two objects appearing as having the same colour under one illuminant can appear as having different colours under a second. Yet since Helmholtz, object colour has generally been believed to remain relatively constant. The deviations from colour constancy registered in experiments are usually thought to be small enough that they do not contradict the notion of colour constancy. However, it is important to determine how the deviations from colour constancy relate to the limits metamer mismatching imposes on constancy. Hence, we calculated metamer mismatching's effect for the 20 Munsell papers and 8 pairs of illuminants employed in the colour constancy study by Logvinenko and Tokunaga and found it to be so extensive that the two notions-metamer mismatching and colour constancy-must be mutually exclusive. In particular, the notion of colour constancy leads to some paradoxical phenomena such as the possibility of 20 objects having the same colour under chromatic light dispersing into a hue circle of colours under neutral light. Thus, colour constancy refers to a phenomenon, which because of metamer mismatching, simply cannot exist. Moreover, it obscures the really important visual phenomenon; namely, the alteration of object colours induced by illumination change. We show that colour is not an independent, intrinsic attribute of an object, but rather an attribute of an object/light pair, and then define a concept of material colour in terms of equivalence classes of such object/light pairs. We suggest that studying the shift in material colour under a change in illuminant will be more fruitful than pursuing colour constancy's false premise that colour is an intrinsic attribute of an object.

  19. Rethinking Colour Constancy.

    Science.gov (United States)

    Logvinenko, Alexander D; Funt, Brian; Mirzaei, Hamidreza; Tokunaga, Rumi

    2015-01-01

    Colour constancy needs to be reconsidered in light of the limits imposed by metamer mismatching. Metamer mismatching refers to the fact that two objects reflecting metameric light under one illumination may reflect non-metameric light under a second; so two objects appearing as having the same colour under one illuminant can appear as having different colours under a second. Yet since Helmholtz, object colour has generally been believed to remain relatively constant. The deviations from colour constancy registered in experiments are usually thought to be small enough that they do not contradict the notion of colour constancy. However, it is important to determine how the deviations from colour constancy relate to the limits metamer mismatching imposes on constancy. Hence, we calculated metamer mismatching's effect for the 20 Munsell papers and 8 pairs of illuminants employed in the colour constancy study by Logvinenko and Tokunaga and found it to be so extensive that the two notions-metamer mismatching and colour constancy-must be mutually exclusive. In particular, the notion of colour constancy leads to some paradoxical phenomena such as the possibility of 20 objects having the same colour under chromatic light dispersing into a hue circle of colours under neutral light. Thus, colour constancy refers to a phenomenon, which because of metamer mismatching, simply cannot exist. Moreover, it obscures the really important visual phenomenon; namely, the alteration of object colours induced by illumination change. We show that colour is not an independent, intrinsic attribute of an object, but rather an attribute of an object/light pair, and then define a concept of material colour in terms of equivalence classes of such object/light pairs. We suggest that studying the shift in material colour under a change in illuminant will be more fruitful than pursuing colour constancy's false premise that colour is an intrinsic attribute of an object.

  20. Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse

    Science.gov (United States)

    Adair, Henry S., III

    1998-07-01

    Current methods for in vivo evaluation of digital hemodynamics in the horse include angiography, scintigraphy, Doppler ultrasound, electromagnetic flow and isolated extracorporeal pump perfused digit preparations. These techniques are either non-quantifiable, do not allow for continuous measurement, require destruction of the horse orare invasive, inducing non- physiologic variables. In vitro techniques have also been reported for the evaluation of the effects of vasoactive agents on the digital vessels. The in vitro techniques are non-physiologic and have evaluated the vasculature proximal to the coronary band. Lastly, many of these techniques require general anesthesia or euthanasia of the animal. Laser Doppler flowmetry is a non-invasive, continuous measure of capillary blood flow. Laser Doppler flowmetry has been used to measure capillary blood flow in many tissues. The principle of this method is to measure the Doppler shift, that is, the frequency change that light undergoes when reflected by moving objects, such as red blood cells. Laser Doppler flowmetry records a continuous measurement of the red cell motion in the outer layer of the tissue under study, with little or no influence on physiologic blood flow. This output value constitutes the flux of red cells and is reported as capillary perfusion units. No direct information concerning oxygen, nutrient or waste metabolite exchange in the surrounding tissue is obtained. The relationship between the flowmeter output signal and the flux of red blood cells is linear. The principles of laser Doppler flowmetry will be discussed and the technique for laminar capillary blood flow measurements will be presented.

  1. Developmental colour agnosia.

    Science.gov (United States)

    van Zandvoort, Martine J E; Nijboer, Tanja C W; de Haan, Edward

    2007-08-01

    Colour agnosia concerns the inability to recognise colours despite intact colour perception, semantic memory for colour information, and colour naming. Patients with selective colour agnosia have been described and the deficit is associated with left hemisphere damage. Here we report a case study of a 43-year-old man who was referred to us with a stroke in his right cerebellar hemisphere. During the standard assessment it transpired that he was unable to name coloured patches. Detailed assessment of his colour processing showed that he suffers from a selective colour agnosia. As he claimed to have had this problem all his life, and the fact that the infratentorial infarct that he had incurred was in an area far away from the brain structures that are known to be involved in colour processing, we suggest that he is the first reported case of developmental colour agnosia.

  2. Noninvasive Doppler tissue measurement of pulmonary artery compliance in children with pulmonary hypertension.

    Science.gov (United States)

    Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin

    2006-04-01

    We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Dynamic compliance (C(dyn)) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C(dyn) was calculated as: [(D(s) - D(d))/(D(d) x P(s))] x 10(4); where D(s) = systolic diameter, D(d) = diastolic diameter, and P(s) = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. C(dyn) was also measured in an additional 13 patients undergoing reactivity studies. Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C(dyn) calculated by CMM DTI agreed with C(dyn) calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C(dyn) values than control subjects (P < .01). C(dyn) values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C(dyn) agreed with reactivity measured using impedance techniques. The C(dyn) method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.

  3. Measurement of subcutaneous adipose tissue blood flow in the morbidly obese using a laser Doppler velocimeter

    Science.gov (United States)

    Klassen, Gerald A.; Paton, Barry E.; Maksym, Geoff; Janigan, David; Perey, Bernard

    1992-08-01

    Using a laser Doppler velocimeter (LDV) subcutaneous adipose tissue blood flow (AF) was recorded in the upright and supine positions in the upper and lower abdomen in 22 morbidly obese patients before gastroplasty. Age was 42 +/- 3 (mean +/- SEM), weight 135 +/- 7 kg, and body mass index (BMI) 51 +/- 3. Adipose flow expressed as mV was: supine, upper abdomen 647 +/- 23, lower abdomen 604 +/- 24; upright, upper abdomen 621 +/- 27, lower abdomen 607 +/- 29. AF was significantly more in the upper than lower abdomen (supine position) and AF was significantly lower in the lower abdomen upright than the upper abdomen supine. Regression analysis of age indicates that blood flow decreases in the lower abdomen so that in the supine position the difference between upper and lower abdomen AF increases. Similar analysis of BMI did not indicate significant trends. These data indicate that with morbid obesity there is lower tissue blood flow to the lower abdomen. This may explain why such patients may develop areas of painful ischemic necrosis in the dependent region of their anterior abdominal pannus.

  4. Synaesthetic Colours Can Behave More like Recalled Colours, as Opposed to Physical Colours that Can Be Seen

    Directory of Open Access Journals (Sweden)

    Derek H. Arnold

    2011-05-01

    Full Text Available Grapheme-color synaesthesia is an atypical condition characterized by coloured sensations when reading achromatic text. Different forms have been characterized, but this is somewhat controversial. In associative grapheme-colour synaesthesia, written graphemes can automatically trigger a sensation of colour in the ‘mind's eye’, but hearing the name of a grapheme does not. This allowed us explore the precision with which synaesthetes match triggered synaesthetic colours across separate presentations, versus the precision for recalled experiences cued by spoken graphemes. We recorded CIE coordinates, and found that matches for triggered sensations were equally variable relative to recalled experiences. To ensure this was not due to insensitivity of our apparatus, we next had synaesthetes and age-matched controls either match the colour of a circular patch while they could see it, or from memory after it had disappeared. Both synaesthetes and controls were more variable when matching from memory, and synaesthetes were more precise when matching colour hue, but not brightness. Interestingly, the variance of synaesthetes' recalled matches in this experiment matched that associated with synaesthetic colours in the first experiment. Overall, our data suggests that, for associative grapheme-colour synaesthetes, synaesthetic colours behave more like recalled colours, as opposed to physical colours that can be seen.

  5. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    Science.gov (United States)

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. True and false memory for colour names versus actual colours: support for the visual distinctiveness heuristic in memory for colour information.

    Science.gov (United States)

    Eslick, Andrea N; Kostic, Bogdan; Cleary, Anne M

    2010-06-01

    In a colour variation of the Deese-Roediger-McDermott (DRM) false memory paradigm, participants studied lists of words critically related to a nonstudied colour name (e.g., "blood, cherry, scarlet, rouge ... "); they later showed false memory for the critical colour name (e.g., "red"). Two additional experiments suggest that participants generate colour imagery in response to such colour-related DRM lists. First, participants claim to experience colour imagery more often following colour-related than standard non-colour-related DRM lists; they also rate their colour imagery as more vivid following colour-related lists. Second, participants exhibit facilitative priming for critical colours in a dot selection task that follows words in the colour-related DRM list, suggesting that colour-related DRM lists prime participants for the actual critical colours themselves. Despite these findings, false memory for critical colour names does not extend to the actual colours themselves (font colours). Rather than leading to source confusion about which colours were self-generated and which were studied, presenting the study lists in varied font colours actually worked to reduce false memory overall. Results are interpreted within the framework of the visual distinctiveness hypothesis.

  7. Gingival Tissue Color Related With Facial Skin and Acrylic Resin ...

    African Journals Online (AJOL)

    The objective of this study is to determine the predominant gingival tissue colour in this environment; to assess the association of gingival tissue colour with gender and facial skin colour. Four hundred and thirty subjects that attended the Dental Centre, University College Hospital, Ibadan, who consented to participate in the ...

  8. Voltage-controlled colour-tunable microcavity OLEDs with enhanced colour purity

    International Nuclear Information System (INIS)

    Choy, Wallace C H; Niu, J H; Li, W L; Chui, P C

    2008-01-01

    The emission spectrum of single-unit voltage-controlled colour-tunable organic light emitting devices (OLEDs) has been theoretically and experimentally studied. Our results show that by introducing the microcavity structure, the colour purity of not only the destination colour but also the colour-tunable route can be enhanced, while colour purity is still an issue in typical single-unit voltage-controlled colour-tunable OLEDs. With the consideration of the periodical cycling of resonant wavelength and absorption loss of the metal electrodes, the appropriate change in the thickness of the microcavity structure has been utilized to achieve voltage-controlled red-to-green and red-to-blue colour-tunable OLEDs without adding dyes or other organic materials to the OLEDs

  9. Cardiac tissue Doppler imaging in sports medicine.

    Science.gov (United States)

    Krieg, Anne; Scharhag, Jürgen; Kindermann, Wilfried; Urhausen, Axel

    2007-01-01

    The differentiation of training-induced cardiac adaptations from pathological conditions is a key issue in sports cardiology. As morphological features do not allow for a clear delineation of early stages of relevant pathologies, the echocardiographic evaluation of left ventricular function is the technique of first choice in this regard. Tissue Doppler imaging (TDI) is a relatively recent method for the assessment of cardiac function that provides direct, local measurements of myocardial velocities throughout the cardiac cycle. Although it has shown a superior sensitivity in the detection of ventricular dysfunction in clinical and experimental studies, its application in sports medicine is still rare. Besides technical factors, this may be due to a lack in consensus on the characteristics of ventricular function in relevant conditions. For more than two decades there has been an ongoing debate on the existence of a supernormal left ventricular function in athlete's heart. While results from traditional echocardiography are conflicting, TDI studies established an improved diastolic function in endurance-trained athletes with athlete's heart compared with controls.The influence of anabolic steroids on cardiac function also has been investigated by standard echocardiographic techniques with inconsistent results. The only TDI study dealing with this topic demonstrated a significantly impaired diastolic function in bodybuilders with long-term abuse of anabolic steroids compared with strength-trained athletes without abuse of anabolic steroids and controls, respectively.Hypertrophic cardiomyopathy is the most frequent cause of sudden death in young athletes. However, in its early stages, it is difficult to distinguish from athlete's heart. By means of TDI, ventricular dysfunction in hypertrophic cardiomyopathy can be disclosed even before the development of left ventricular hypertrophy. Also, a differentiation of left ventricular hypertrophy due to hypertrophic

  10. Translational and Brownian motion in laser-Doppler flowmetry of large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Seghier, M L; Delpy, D T

    2004-01-01

    This study reports the derivation of a precise mathematical relationship existing between the different p-moments of the power spectrum of the photoelectric current, obtained from a laser-Doppler flowmeter (LDF), and the red blood cell speed. The main purpose is that both the Brownian (defining the 'biological zero') and the translational movements are taken into account, clarifying in this way what the exact contribution of each parameter is to the LDF derived signals. The derivation of the equations is based on the quasi-elastic scattering theory and holds for multiple scattering (i.e. measurements in large tissue volumes and/or very high red blood cell concentration). The paper also discusses why experimentally there exists a range in which the relationship between the first moment of the power spectrum and the average red blood cells speed may be considered as 'linear' and what are the physiological determinants that can result in nonlinearity. A correct way to subtract the biological zero from the LDF data is also proposed. The findings should help in the design of improved LDF instruments and in the interpretation of experimental data

  11. [Two- and three-dimensional power Doppler ultrasound in the follow-up of placenta accreta treated conservatively].

    Science.gov (United States)

    Roulot, A; Barranger, E; Morel, O; Soyer, P; Héquet, D

    2015-02-01

    To determinate the potential of 2D and 3D-ultrasound in the follow-up of patients with placenta accreta treated conservatively. Seven patients with placenta accreta treated conservatively during June 2007 and September 2009 were included. The follow-up consisted in clinical examination and 2D/3D-ultrasound once a month. Criteria studied included clinical outcome, echogenicity at 2D-ultrasound, vascularisation at colour Doppler, Mean Grey at 3D-ultrasound and vascularisation, flow and perfusion index. Seven women with invasive placenta (3 placentas accreta and 2 percreta) were studied. The mean follow-up was 228 days [75-369]. Mean delay for complete elimination of residual placenta was 280 days [120-365]. The two main results were: presence of an increased anechogenicpart in residual placenta before complete resorption for all patients; a systematic and concomitant stop of genital haemorrhage and vascularisation at colour Doppler. High degrees of variability in parameters measured at 3D-ultrasound were observed between patients so that correlations with clinical outcome were found. Long and regular follow-up is essential after conservative management but the role of 3D-ultrasound compared to 2D-ultrasound was not demonstrated in this study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Seminal, clinical and colour-Doppler ultrasound correlations of prostatitis-like symptoms in males of infertile couples.

    Science.gov (United States)

    Lotti, F; Corona, G; Mondaini, N; Maseroli, E; Rossi, M; Filimberti, E; Noci, I; Forti, G; Maggi, M

    2014-01-01

    'Prostatitis-like symptoms' (PLS) are a cluster of bothersome conditions defined as 'perineal and/or ejaculatory pain or discomfort and National Institutes of Health-Chronic Prostatitis Symptom Index (NIH-CPSI) pain subdomain score ≥4' (Nickel's criteria). PLS may originate from the prostate or from other portions of the male genital tract. Although PLS could be associated with 'prostatitis', they should not be confused. The NIH-CPSI is considered the gold-standard for assessing PLS severity. Although previous studies investigated the impact of prostatitis, vesiculitis or epididymitis on semen parameters, correlations between their related symptoms and seminal or scrotal/transrectal colour-Doppler ultrasound (CDU) characteristics have not been carefully determined. And no previous study evaluated the CDU features of PLS in infertile men. This study was aimed at investigating possible associations among NIH-CPSI (total and subdomain) scores and PLS, with seminal, clinical and scrotal/transrectal CDU parameters in a cohort of males of infertile couples. PLS of 400 men (35.8 ± 7.2 years) with a suspected male factor were assessed by the NIH-CPSI. All patients underwent, during the same day, semen analysis, seminal plasma interleukin 8 (sIL-8, a marker of male genital tract inflammation), biochemical evaluation, urine/seminal cultures, scrotal/transrectal CDU. PLS was detected in 39 (9.8%) subjects. After adjusting for age, waist and total testosterone (TT), no association among NIH-CPSI (total or subdomain) scores or PLS and sperm parameters was observed. However, we found a positive association with current positive urine and/or seminal cultures, sIL-8 levels and CDU features suggestive of inflammation of the epididymis, seminal vesicles, prostate, but not of the testis. The aforementioned significant associations of PLS were further confirmed by comparing PLS patients with age-, waist- and TT-matched PLS-free patients (1 : 3 ratio). In conclusion, NIH

  13. Recolouring-resistant colourings

    DEFF Research Database (Denmark)

    Pedersen, A. S.; Rautenbach, D.

    2011-01-01

    We study colourings of graphs with the property that the number of used colours cannot be reduced by applying some recolouring operation. A well-studied example of such colourings are b-colourings, which were introduced by Irving and Manlove [R.W. Irving, D.F. Manlove, The la-chromatic number...... of a graph, Discrete Appl. Math. 91 (1999) 127-141]. Given a graph and a colouring, a recolouring operation specifies a set of vertices of the graph on which the colouring can be changed. We consider two such operations: One which allows the recolouring of all vertices within some given distance of some...... colour class, and another which allows the recolouring of all vertices that belong to one of a given number of colour classes. Our results extend known results concerning b-colourings and the associated b-chromatic number. (C) 2011 Elsevier B.V. All rights reserved....

  14. Doppler ultrasound for diagnosis of soft tissue sarcoma: efficacy of ultrasound-based screening score

    Directory of Open Access Journals (Sweden)

    Nagano Satoshi

    2015-06-01

    Full Text Available Background. The utility of ultrasound imaging in the screening of soft-part tumours (SPTs has been reported. We classified SPTs according to their blood flow pattern on Doppler ultrasound and re-evaluated the efficacy of this imaging modality as a screening method. Additionally, we combined Doppler ultrasound with several values to improve the diagnostic efficacy and to establish a new diagnostic tool.

  15. The role of colour doppler ultrasonography of facial and occipital arteries in patients with giant cell arteritis: A prospective study.

    Science.gov (United States)

    Ješe, Rok; Rotar, Žiga; Tomšič, Matija; Hočevar, Alojzija

    2017-10-01

    Colour Doppler Sonography (CDS) in giant cell arteritis (GCA) allows the study of involvement of cranial arteries other than the temporal arteries, which are inconvenient to biopsy, such as the facial (FaA), and occipital (OcA) arteries. We aimed to estimate the frequency of the FaA, and OcA involvement in GCA; and to explore the clinical characteristics of these subgroups of patients. From 1 January 2014 to 31 December 2016 we prospectively performed a CDS of the FaA, and OcA in addition to the temporal (TA), and the extracranial supra-aortic arteries in all newly diagnosed patients suspected of having GCA. All the arteries were evaluated in two planes for the highly specific halo sign. During the 36-month observation period we performed a CDS of the cranial and extra-cranial arteries in 93 GCA patients. We observed the halo sign on the FaA, and OcA in 38 (40.9%), and 29 (31.2%) cases, respectively. The FaA, or OcA were affected in 4/22 (18.2%) patients with a negative TA CDS. FaA involvement significantly correlated with jaw claudication and with severe visual manifestations, including permanent visual loss. A fifth of patients with a negative CDS of the TAs had signs of vasculitis on the CDS of the FaA, or OcA. The addition of FaA and OcA CDS to the routine CDS of the TAs could identify 4.3% more patients and thus further improve the sensitivity of the CDS in the suspected GCA. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Usefulness of the myocardial performance index determined by tissue Doppler imaging m-mode for predicting mortality in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Haahr-Pedersen, Sune Ammentorp

    2011-01-01

    The objective of this study was to evaluate the prognostic value of the myocardial performance index (MPI), assessed by color-coded tissue Doppler imaging (TDI) M-mode through the anterior mitral leaflet. Color TDI M-mode through the mitral leaflet is an easy, very fast, and precise method...... ventricular in- and outflow using standard procedures (MPI(conv)) and by color-coded TDI M-mode through the mitral leaflet in the apical 4-chamber view (MPI(TDI)). MPI(TDI) was increased in subjects with coronary heart disease (CHD) compared to controls, even after multivariable adjustment (p

  17. Is colour cognitive?

    Science.gov (United States)

    Skorupski, Peter; Chittka, Lars

    2011-03-01

    In recent years, colour-vision abilities have been rather generously ascribed to various invertebrates and even bacteria. This uncertainty of when to diagnose colour vision stems in part from confusing what colour vision can do with what it is. What colour vision can do is discriminate wavelength independent of intensity. However, if we take this as a definition of what colour vision is, then we might be obliged to conclude that some plants and bacteria have colour vision. Moreover, there is a similar confusion of what are necessary and what are sufficient mechanisms and behavioural abilities for colour vision. To humans, seeing in colour means seeing an image in which objects/lights have chromatic attributes—in contrast to the sensation that we have when viewing monochrome movies, or our experience in dim light when only rod vision is possible. The necessary basic equipment for this is to have at least two types of photoreceptors that differ in spectral sensitivity, and at least one type of spectrally opponent cell to compare the signals from the photoreceptors. Clearly, however, a necessary additional prerequisite for colour vision is to have vision, which entails the identification of shapes, sizes and locations of objects in the world. Thus, if an animal has colour vision, it should see an image in which distinct objects/lights have colour attributes. This distinguishes colour vision from wavelength discrimination, but also from what has historically been called wavelength-specific behaviour: a type of behaviour triggered by fixed configurations of spectral receptor signals; however, we discuss difficulties in diagnosing wavelength-specific behaviour as an indicator of the absence of colour vision. Finally, we discuss whether colour vision, by definition, contains a cognitive dimension for ordering and classifying perceptual experience.

  18. Plasmonic colour generation

    DEFF Research Database (Denmark)

    Kristensen, Anders; Yang, Joel K. W.; Bozhevolnyi, Sergey I.

    2016-01-01

    Plasmonic colours are structural colours that emerge from resonant interactions between light and metallic nanostructures. The engineering of plasmonic colours is a promising, rapidly emerging research field that could have a large technological impact. We highlight basic properties of plasmonic...... colours and recent nanofabrication developments, comparing technology-performance indicators for traditional and nanophotonic colour technologies. The structures of interest include diffraction gratings, nanoaperture arrays, thin films, and multilayers and structures that support Mie resonances...... and whispering-gallery modes. We discuss plasmonic colour nanotechnology based on localized surface plasmon resonances, such as gap plasmons and hybridized disk–hole plasmons, which allow for colour printing with sub-diffraction resolution. We also address a range of fabrication approaches that enable large...

  19. Temporal and spatial regulation of anthocyanin biosynthesis provide diverse flower colour intensities and patterning in Cymbidium orchid.

    Science.gov (United States)

    Wang, Lei; Albert, Nick W; Zhang, Huaibi; Arathoon, Steve; Boase, Murray R; Ngo, Hanh; Schwinn, Kathy E; Davies, Kevin M; Lewis, David H

    2014-11-01

    This study confirmed pigment profiles in different colour groups, isolated key anthocyanin biosynthetic genes and established a basis to examine the regulation of colour patterning in flowers of Cymbidium orchid. Cymbidium orchid (Cymbidium hybrida) has a range of flower colours, often classified into four colour groups; pink, white, yellow and green. In this study, the biochemical and molecular basis for the different colour types was investigated, and genes involved in flavonoid/anthocyanin synthesis were identified and characterised. Pigment analysis across selected cultivars confirmed cyanidin 3-O-rutinoside and peonidin 3-O-rutinoside as the major anthocyanins detected; the flavonols quercetin and kaempferol rutinoside and robinoside were also present in petal tissue. β-carotene was the major carotenoid in the yellow cultivars, whilst pheophytins were the major chlorophyll pigments in the green cultivars. Anthocyanin pigments were important across all eight cultivars because anthocyanin accumulated in the flower labellum, even if not in the other petals/sepals. Genes encoding the flavonoid biosynthetic pathway enzymes chalcone synthase, flavonol synthase, flavonoid 3' hydroxylase (F3'H), dihydroflavonol 4-reductase (DFR) and anthocyanidin synthase (ANS) were isolated from petal tissue of a Cymbidium cultivar. Expression of these flavonoid genes was monitored across flower bud development in each cultivar, confirming that DFR and ANS were only expressed in tissues where anthocyanin accumulated. Phylogenetic analysis suggested a cytochrome P450 sequence as that of the Cymbidium F3'H, consistent with the accumulation of di-hydroxylated anthocyanins and flavonols in flower tissue. A separate polyketide synthase, identified as a bibenzyl synthase, was isolated from petal tissue but was not associated with pigment accumulation. Our analyses show the diversity in flower colour of Cymbidium orchid derives not from different individual pigments but from subtle

  20. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    Science.gov (United States)

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p foot reflexology. There was no difference between men and women and no difference between smokers and non-smokers. Verum and placebo group significantly differed concerning alterations of the resistive index both between the measuring points before versus during foot reflexology (p = 0.002) and those during versus after foot reflexology (p = 0.031). The significant decrease of the resistive index during foot reflexology in the verum group indicates a decrease of flow resistance in renal vessels and an increase of renal blood flow. These findings support the hypothesis that organ-associated foot reflexology is effective in changing renal blood flow during therapy.

  1. What colour is the car? Implicit memory for colour information in children.

    Science.gov (United States)

    Mecklenbräuker, S; Hupbach, A; Wippich, W

    2001-11-01

    Three experiments were conducted to examine age-related differences in colour memory. In Experiment 1, preschool age and elementary school age children were given a conceptual test of implicit colour memory (a colour-choice task). They were presented with the names or achromatic versions of previously studied coloured line drawings and asked to select an appropriate colour. Significant priming could be demonstrated: The children chose the previously seen colours more often than was expected by chance. Equivalent priming was found for both versions (pictorial and verbal) suggesting that colour priming may be conceptually mediated. Moreover, colour priming proved to be age invariant. Experiment 2 replicated and extended this finding by using a wider age group (preschool, elementary school, and young adults) and by giving a perceptual implicit task (picture identification) in addition to a verbal colour-choice task. Colour did not affect priming in the perceptual task. Whereas priming showed no developmental change, age-related improvements were observed on an explicit colour memory task that differed only in the test instructions from the implicit colour-choice task (Experiments 2 and 3). Taken together, the results suggest that implicit colour memory may be mediated by conceptual processes that are age invariant.

  2. Measuring Colour

    CERN Document Server

    Hunt, R W G

    2011-01-01

    The classic authority on colour measurement now fully revised and updated with the latest CIE recommendations The measurement of colour is of major importance in many commercial applications, such as the textile, paint, and foodstuff industries; as well as having a significant role in the lighting, paper, printing, cosmetic, plastics, glass, chemical, photographic, television, transport, and communication industries. Building upon the success of earlier editions, the 4th edition of Measuring Colour has been updated throughout with new chapters on colour rendering by light sources; colorimetry

  3. Trans-skull ultrasonic Doppler system aided by fuzzy logic

    Science.gov (United States)

    Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto

    2012-06-01

    This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.

  4. Tissue Doppler echocardiography in persons with hypertension, diabetes, or ischaemic heart disease: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Mogelvang, Rasmus; Sogaard, Peter; Pedersen, Sune A

    2009-01-01

    AIMS: To test the hypothesis that echocardiographic tissue Doppler imaging (TDI) reveals reduced myocardial function in hypertension, diabetes, and ischaemic heart disease (IHD) in the general population. METHODS AND RESULTS: Within a large, community-based population study, cardiac function...... and diastolic cardiac function in hypertension [n = 345; LD 10.1 (+/-standard deviation, SD 2.0 mm), P diabetes [n = 65; LD 9.8 (+/-SD 2.2 mm), P ....001] compared with controls [n = 533; LD 11.4 (+/-SD 2.0 mm); E/e' 9.0 (x/SD 1.3)]. This pattern remained significant after adjusting for age, sex, body mass index, heart rate, and the results of conventional echocardiography. CONCLUSION: In the general population, persons with hypertension, diabetes, or IHD...

  5. Colour Studies

    African Journals Online (AJOL)

    DR Nneka

    2015-04-14

    Apr 14, 2015 ... failure of the student to differentiate what is of particular concern to him or her, and .... perception of the physical appearance of colour and our ..... Colour is perceived in different modes and dimension and has derivative ..... which pigment colours can effectively depict existing realities, express emotions and.

  6. Análisis de perforantes de la epigástrica inferior profunda con Angio TC 3D, Eco Doppler color y Doppler simple de ultrasonidos en colgajo DIEP: resultados preliminares Analysis of deep inferior epigastric perforating vessels with 3D CT angiography, color Doppler ultrasonography and Doppler in diep flaps: preliminary results

    Directory of Open Access Journals (Sweden)

    J. Castro García

    2008-09-01

    Doppler ultrasound, Colour-Duplex and Angio-CT with three-dimentional reconstruction. Surgical procedure findings were considered as the reference value. The evaluation procedure included the election of the most suitable perforator vessels, taking account of the location, caliber and anatomical relationships with the muscle. The Angio-CT with three-dimentional reconstruction showed 100% specificity (CI 95% 75.3-100, and very high positive predictive value. In this way, this technique could be considered as an excellent tool for preoperative evaluation of perforators flaps. Color-Duplex showed that in 46,1% of the patients (CI 95% 19,2-74% the selected perforator matched with the intraoperatively selected. Using Doppler ultrasound only in 30,8% of the cases (IC 95% 9,1-61,4% this result was observed. In this report, Angio-CT with three-dimentional reconstruction has revealed as a very high specificity technique, that allows a great account of important information, only comparable with anatomical dissection and ahead from Doppler ultrasound and color-Dupplex.

  7. Synaesthetic Colours Can Behave More like Recalled Colours, as Opposed to Physical Colours that Can Be Seen

    OpenAIRE

    Derek H. Arnold; Signy V. Wegener; Francesca Brown; Jason B. Mattingley

    2011-01-01

    Grapheme-color synaesthesia is an atypical condition characterized by coloured sensations when reading achromatic text. Different forms have been characterized, but this is somewhat controversial. In associative grapheme-colour synaesthesia, written graphemes can automatically trigger a sensation of colour in the ?mind's eye?, but hearing the name of a grapheme does not. This allowed us explore the precision with which synaesthetes match triggered synaesthetic colours across separate presenta...

  8. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  9. The colour of an avifauna: A quantitative analysis of the colour of Australian birds

    Science.gov (United States)

    Delhey, Kaspar

    2015-01-01

    Animal coloration is a poorly-understood aspect of phenotypic variability. Here I expand initial studies of the colour gamut of birds by providing the first quantitative description of the colour variation of an entire avifauna: Australian landbirds (555 species). The colour of Australian birds occupies a small fraction (19%) of the entire possible colour space and colour variation is extremely uneven. Most colours are unsaturated, concentrated in the centre of colour space and based on the deposition of melanins. Other mechanisms of colour production are less common but account for larger portions of colour space and for most saturated colours. Male colours occupy 45–25% more colour space than female colours, indicating that sexual dichromatism translates into a broader range of male colours. Male-exclusive colours are often saturated, at the edge of chromatic space, and have most likely evolved for signalling. While most clades of birds occupy expected or lower-than-expected colour volumes, parrots and cockatoos (Order Psittaciformes) occupy a much larger volume than expected. This uneven distribution of colour variation across mechanisms of colour production, sexes and clades is probably shared by avifaunas in other parts of the world, but this remains to be tested with comparable data. PMID:26679370

  10. Detection of coloured tracks of heavy ion particles using photographic colour film

    International Nuclear Information System (INIS)

    Kuge, K.; Yasuda, N.; Kumagai, H.; Nakazawa, K.; Kobayashi, T.; Aoki, N.; Hasegawa, A.

    2001-01-01

    A photographic colour film, which was exposed to heavy ions, reveals a coloured dye image of the ion tracks. Since the colour film consists of several layers and different colours appear on each layer, three-dimensional information on the tracks in the layers can be obtained by the colour image. Previously, we have reported the method for which the tracks in different colours represented differences of track depth and we also discussed the disadvantages of using commercial colour films. Here we present the procedure for a self-made photographic coating and the development formula which can overcome the disadvantages

  11. New clutter-rejection algorithm for Doppler ultrasound

    Science.gov (United States)

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2002-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): a time-varying low frequency component (type 1), covering systole and early diastole, and short transient clutter signals (type 2), distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted until the signal-to-clutter (S/C) ratio reached a maximum. For the type 1 clutter signal, the improvement in the S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient type 2 clutter signal, exactly 10 atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  12. Colour printing techniques

    OpenAIRE

    Parraman, C.

    2017-01-01

    Invited chapter in the book Colour Design: Theories and Applications. In PART 3 COLOUR, DESIGN AND COLORATION this chapter covers:\\ud - Hardcopy colour: analogue versus digital\\ud - Colour theory in relation to printing\\ud - Overview of halftoning and digital print technologies\\ud - Overview and development of inks\\ud - Inkjet papers and inks\\ud - Recent and future trends in colour, printing inks and hardware.\\ud \\ud This book differs from other existing books in the field, with the aim of an...

  13. Colour intransparency and the cross sections for colour-singlet and colour-octet hadrons in the Low-Nussinov model

    International Nuclear Information System (INIS)

    Dolejsi, J.; Huefner, J.

    1992-01-01

    The dependence of cross sections on the colour state of the colliding hadrons is investigated within the Low-Nussinov model of two-gluon exchange. The total cross sections for colour-octet hadrons are practically constant as functions of the hadronic radii, while they tend to zero when the radii of the colour-singlet hadrons approach zero. The slope parameter of the differential elastic cross sections for small momentum transfers is rather insensitive to the colour structure of the colliding hadrons. The integrated colour exchange cross section is calculated. (orig.)

  14. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    OpenAIRE

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 ...

  15. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  16. Joint pain and Doppler-detectable bubbles in altitude (Hypobaric) decompression

    Science.gov (United States)

    Powell, Michael R.

    1993-01-01

    The observation that altitude decompression sickness (DCS) is associated with pain in the lower extremities is not new, although it is not a consistent finding. DCS in divers is generally in the upper body, an effect often attributed to non-loading of the body while immersed. In caisson workers, DCS is reported more in the lower extremities. Surprisingly, many researchers do not mention the location of DCS joint pain, apparently considering it to be random. This is not the case for the tissue ratios encountered in studying decompression associated with simulated EVA. In NASA/JSC tests, altitude DCS generally presented first in either the ankle, knee, or hip (83 percent = 73/88). There was a definite statistical relation between the maximum Spencer precordial Doppler Grade and the incidence of DCS in the extremity, although this is not meant to imply a casual relation between circulating gas bubbles and joint pain. The risk of DCS with Grade 4 was considerably higher than that of Grades 0 to 3. The DCS risk was independent of the 'tissue ratio.' There was a predominance of lower extremity DCS even when exercise was performed with the upper body. The reason for these locations we hypothesize to be attributed to the formation of tissue gas micronuclei from kinetic and tensile forces (stress-assisted nucleation) and are the result of the individuals ambulating in a 1g environment. Additionally, since these showers of Doppler bubbles can persist for hours, it is difficult to imagine that they are emanating solely from tendons and ligaments, the supposed site of joint pain. This follows from Henry's law linking the volume of joint tissue (the solvent) and the solubility coefficient of inert gas; there is volumetrically insufficient connective tissue to produce the prolonged release of gas bubbles. If gas bubbles are spawned and released from connective tissue, their volume is increased by those from muscle tissue. Therefore, the nexus between Doppler-detectable gas

  17. Evaluation of left ventricular function in obese children without hypertension by a tissue Doppler imaging study.

    Science.gov (United States)

    Ghandi, Yazdan; Sharifi, Mehrzad; Habibi, Danial; Dorreh, Fatemeh; Hashemi, Mojtaba

    2018-01-01

    The prevalence of obesity is increasing worldwide. Obese children without hypertension are becoming an important health challenge. Complications of obesity in adults are well established, but in obese children, cardiac dysfunction has not been reported clinically. The present crosssectional study investigates subclinical systolic and diastolic dysfunction using echocardiographic modalities. Twentyfive youngsters with body mass index (BMI) >30 and 25 healthy children with BMI <25 were assigned into case and control group, respectively. In all participants, complete cardiovascular examination, electrocardiography, and echocardiography were fulfilled. Echocardiography surveys included standard, pulsed wave Doppler (PWD), and tissue Doppler imaging (TDI). SPSS software, version 24. The two groups were matched for age and sex. The resting heart rate and blood pressure were markedly higher in the obese group ( P = 0.0001) though they were within the normal range in either category. Ejection fraction in the two groups was similar. Left ventricular (LV) mass ( P = 0.0001), LV mass index ( P = 0.029), left atrialtoaortic diameter ratio ( P = 0.0001), and LV enddiastolic diameter ( P = 0.008) were significantly greater in the case group, indicating cardiomegaly and subclinical systolic and diastolic dysfunction. Except for the aortic velocity, all PWD variables were considerably lower in the case group, suggesting subclinical diastolic dysfunction. All TDI parameters varied significantly between the two categories. There was a direct correlation between isovolumetric relaxation time and BMI. Obesity in children without hypertension is associated with subclinical systolic and diastolic cardiac dysfunction. We propose the evaluation of blood pressure as well as myocardial performance using PWD and TDI in all obese children without hypertension, regularly.

  18. Measurements and modelling of the influence of dentine colour and enamel on tooth colour.

    Science.gov (United States)

    Battersby, Paul D; Battersby, Stephen J

    2015-03-01

    We provide a quantitative predictive model for the extent to which coloured dentine, visible through the enamel, contributes to tooth colour. Our model uses (L(*),a(*),b(*)) measurements rather than spectral measurements. We have used a model system, composed of a slice of bovine enamel placed on top of coloured paper. We have measured the colour of the enamel-paper combination, as an analogue for a tooth, and have related this to the colour of the paper, as an analogue for dentine. By changing the paper colour, we have been able to explore how the colour of dentine determines tooth colour, according to our model system. We have also compared hydrated and desiccated samples. In qualitative terms, superimposing the enamel on top of the paper increases the "lightness" for all colours tested except white while simultaneously reducing the chromaticity, a measure of the extent to which the colour differs from grey. Desiccated enamel is much more effective at increasing the lightness and reducing the chromaticity than hydrated enamel. Quantitatively, our measurements are reproduced by the mathematical model we have developed to within 2% in "lightness" and about 8% in chromaticity. We are able to predict the colour of an analogue for a tooth, composed of bovine enamel and coloured paper, from the colour of an analogue for the dentine, the coloured paper alone, with good accuracy. This understanding provides insights into the role of dentine colour in determining tooth colour. Our work helps quantify the importance of dentine colour, compared to other, extrinsic causes of colour, such as staining, in determining the visible colour of teeth. Our predicted colours represent a baseline to which extrinsic sources will add. Copyright © 2015. Published by Elsevier Ltd.

  19. Colours sometimes count : Awareness and bidirectionality in grapheme-colour synaesthesia

    NARCIS (Netherlands)

    Johnson, Addie; Jepma, Marieke; de Jong, Ritske

    2007-01-01

    Three experiments were conducted with 10 grapheme-colour synaesthetes and 10 matched controls to investigate (a) whether awareness of the inducer grapheme is necessary for synaesthetic colour induction and (b) whether grapheme-colour synaesthesia may be bidirectional in the sense that not only do

  20. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  1. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    Science.gov (United States)

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P closure (P closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  2. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  3. Colour Blocking: Disregarding Traditional Artistic Colour Harmonies ...

    African Journals Online (AJOL)

    A development in the world of design – costume, fashion, graphics, architecture and general decor whereby traditional colour harmonies are reengineered to suite the taste of the time engages the attention of the paper. The trending phenomenon popularly referred to as 'colour blocking' involves the use of bright ...

  4. Colour perception in ADHD

    NARCIS (Netherlands)

    Banaschewski, T.; Ruppert, S; Tannock, R.; Albrecht, B.; Becker, A.; Uebel, H.; Sergeant, J.A.; Rothenberger, A.

    2006-01-01

    Attention-deficit/hyperactivity disorder (ADHD) is associated with unexplained impairments on speeded naming of coloured stimuli. These deficits may reflect hypofunctioning retinal dopaminergic mechanisms impairing particularly blue-yellow colour discrimination. Colour perception and rapid colour

  5. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  6. COLOUR THEREPY-BOON TO MANKIND

    OpenAIRE

    Dr.Sajan Kurien Mathew

    2017-01-01

    Colour Therapy is a complementary therapy for which there is evidence dating back thousands of years to the ancient cultures of Egypt, China and India. Colour is simply light of varying wavelengths, thus each colour has its own particular wavelength and energy. "Colour affects our life. Colour is physical..........we see it. Colour communicates............we recieve information from the language of colour. Colour is emotional..........it evokes our feeling."1 The energy relating to each of th...

  7. Exploring the functional nature of synaesthetic colour: Dissociations from colour perception and imagery.

    Science.gov (United States)

    Chiou, Rocco; Rich, Anina N; Rogers, Sebastian; Pearson, Joel

    2018-08-01

    Individuals with grapheme-colour synaesthesia experience anomalous colours when reading achromatic text. These unusual experiences have been said to resemble 'normal' colour perception or colour imagery, but studying the nature of synaesthesia remains difficult. In the present study, we report novel evidence that synaesthetic colour impacts conscious vision in a way that is different from both colour perception and imagery. Presenting 'normal' colour prior to binocular rivalry induces a location-dependent suppressive bias reflecting local habituation. By contrast, a grapheme that evokes synaesthetic colour induces a facilitatory bias reflecting priming that is not constrained to the inducing grapheme's location. This priming does not occur in non-synaesthetes and does not result from response bias. It is sensitive to diversion of visual attention away from the grapheme, but resistant to sensory perturbation, reflecting a reliance on cognitive rather than sensory mechanisms. Whereas colour imagery in non-synaesthetes causes local priming that relies on the locus of imagined colour, imagery in synaesthetes caused global priming not dependent on the locus of imagery. These data suggest a unique psychophysical profile of high-level colour processing in synaesthetes. Our novel findings and method will be critical to testing theories of synaesthesia and visual awareness. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Memory colours and colour quality evaluation of conventional and solid-state lamps.

    Science.gov (United States)

    Smet, Kevin A G; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2010-12-06

    A colour quality metric based on memory colours is presented. The basic idea is simple. The colour quality of a test source is evaluated as the degree of similarity between the colour appearance of a set of familiar objects and their memory colours. The closer the match, the better the colour quality. This similarity was quantified using a set of similarity distributions obtained by Smet et al. in a previous study. The metric was validated by calculating the Pearson and Spearman correlation coefficients between the metric predictions and the visual appreciation results obtained in a validation experiment conducted by the authors as well those obtained in two independent studies. The metric was found to correlate well with the visual appreciation of the lighting quality of the sources used in the three experiments. Its performance was also compared with that of the CIE colour rendering index and the NIST colour quality scale. For all three experiments, the metric was found to be significantly better at predicting the correct visual rank order of the light sources (p < 0.1).

  9. Colour Perception in ADHD

    Science.gov (United States)

    Banaschewski, Tobias; Ruppert, Sinje; Tannock, Rosemary; Albrecht, Bjorn; Becker, Andreas; Uebel, Henrik; Sergeant, Joseph A.; Rothenberger, Aribert

    2006-01-01

    Attention-deficit/hyperactivity disorder (ADHD) is associated with unexplained impairments on speeded naming of coloured stimuli. These deficits may reflect hypofunctioning retinal dopaminergic mechanisms impairing particularly blue-yellow colour discrimination. Colour perception and rapid colour naming ability were investigated in 14 children…

  10. Modeling and processing of laser Doppler reactive hyperaemia signals

    Science.gov (United States)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  11. Colour and magnetic monopoles

    International Nuclear Information System (INIS)

    Corrigan, E.; Olive, D.

    1976-01-01

    If the exact gauge symmetry of nature consists of the U(1)sub(EM) generated by the electric charge operator Q and the colour group K, with Q a colour singlet, then, if g is a possible magnetic charge, exp(4πigQ) must equal an element of the colour group. For colour singlet particles this reduces to Dirac's condition eg = n/2. In general, possible monopoles correspond to points of intersection of the colour and electromagnetic groups. If the colour group is semi-simple and compact, there can at most be a finite number p of such points (p = N if K = SU(N)). The existence of non-trivial (not equal to unity) solutions to our condition means that there must be fractionally charged (with p the fraction) coloured particles and magnetic monopoles emanating colour magnetic flux as well as electromagnetic flux. (Auth.)

  12. Colour perception in ADHD

    OpenAIRE

    Banaschewski, T.; Ruppert, S; Tannock, R.; Albrecht, B.; Becker, A.; Uebel, H.; Sergeant, J.A.; Rothenberger, A.

    2006-01-01

    Attention-deficit/hyperactivity disorder (ADHD) is associated with unexplained impairments on speeded naming of coloured stimuli. These deficits may reflect hypofunctioning retinal dopaminergic mechanisms impairing particularly blue-yellow colour discrimination. Colour perception and rapid colour naming ability were investigated in 14 children with ADHD and 13 healthy peers matched for age, gender, and IQ, using the Farnsworth-Munsell 100 Hue Test (FMT) and the Stroop-Colour-Word test. Childr...

  13. Two-dimensional Fourier analysis of the spongy medullary keratin of structurally coloured feather barbs

    Science.gov (United States)

    Prum, R. O.; Torres, R.; Williamson, S.; Dyck, J.

    1999-01-01

    We conducted two-dimensional (2D) discrete Fourier analyses of the spatial variation in refractive index of the spongy medullary keratin from four different colours of structurally coloured feather barbs from three species of bird: the rose-faced lovebird, Agapornis roseicollis (Psittacidae), the budgerigar, Melopsittacus undulatus (Psittacidae), and the Gouldian finch, Poephila guttata (Estrildidae). These results indicate that the spongy medullary keratin is a nanostructured tissue that functions as an array of coherent scatterers. The nanostructure of the medullary keratin is nearly uniform in all directions. The largest Fourier components of spatial variation in refractive index in the tissue are of the appropriate size to produce the observed colours by constructive interference alone. The peaks of the predicted reflectance spectra calculated from the 2D Fourier power spectra are congruent with the reflectance spectra measured by using microspectrophotometry. The alternative physical models for the production of these colours, the Rayleigh and Mie theories, hypothesize that medullary keratin is an incoherent array and that scattered waves are independent in phase. This assumption is falsified by the ring-like Fourier power spectra of these feathers, and the spacing of the scattering air vacuoles in the medullary keratin. Structural colours of avian feather barbs are produced by constructive interference of coherently scattered light waves from the optically heterogeneous matrix of keratin and air in the spongy medullary layer.

  14. Measuring colour

    National Research Council Canada - National Science Library

    Hunt, R. W. G; Pointer, Michael, Ph. D

    2011-01-01

    ... industries.Building upon the success of earlier editions, the 4th edition of [start italics]Measuring Colour[end italics] has been updated throughout with new chapters on colour rendering by light sources...

  15. Colourful FKS subtraction

    CERN Document Server

    Frixione, Stefano

    2011-01-01

    I formulate in a colour-friendly way the FKS method for the computation of QCD cross sections at the next-to-leading order accuracy. This is achieved through the definition of subtraction terms for squared matrix elements, constructed with single colour-dressed or pairs of colour-ordered amplitudes. The latter approach relies on the use of colour flows, is exact to all orders in $N$, and is thus particularly suited to being organized as a systematic expansion in 1/N.

  16. The colours of CERN

    CERN Multimedia

    Laëtitia Pedroso

    2010-01-01

    Would you move into an office painted in a colour you hate? As we all know, taste in colour is individual. Thanks to the establishment of a new Painting Charter, conflicting opinions will be unified.   The four new paint colours established in the Painting Charter. There were many reasons behind the creation of the Painting Charter by the GS SEM Department. Unlike many companies, CERN has not until now regulated which colours can be used inside buildings. With many nationalities passing through CERN, tastes tend to differ: northern countries usually prefer colder colours, while southern countries seem to prefer warm colours. It’s not hard to imagine how quickly we could make a rainbow! In addition, whenever an office needs to be repainted, it can be difficult to find exactly the same colour. This results in entire walls being repainted, which increases the cost. If – by chance – the original colour is found, it could be out of stock. While ...

  17. Doppler-broadening of positron annihilation in a biological environment

    International Nuclear Information System (INIS)

    Torrisi, L.; La Mela, C.; Catania, Univ.

    1997-01-01

    The aim of this study was to investigate the Doppler effect of the 511 keV γ peak from positron annihilation in biological matter: The broadening of the annihilation peak is due to positron annihilation with electrons that have high momentum. In aqueous solutions annihilation depends on the temperature and it is linked positronium formation. Measurements in vivo, on human brain, were taken during the diagnosis of positron emission tomography (PET) on healthy patients by injecting them with the beta emitter of short lifetime 18F . The Doppler-broadening in biological tissues rich in water content decreased significantly compared to biological solutions and water

  18. Subjective estimates of colour attributes for surface colours

    NARCIS (Netherlands)

    Ishak, I.G.H.; Bouma, H.; van Bussel, H.J.J.

    1970-01-01

    Subjective estimates of hue, saturation, and lightness are reported for sixty coloured Munsell samples, shown against seven backgrounds (black, grey, white, red, yellow, green, and blue) as judged by two observers. The results show the adequacy of this method for studies on colour appearance. The

  19. Evaluation of Cardiovascular System in Fibromyalgia Syndrome: Tissue Doppler Echocardiographic Investigation

    Directory of Open Access Journals (Sweden)

    Selma YAZICI

    2010-05-01

    Full Text Available Aim: We aim to investigate besides the cardiac structures and functions by both conventionalmethods and Tissue Doppler Echocardiography (TDE which is a new and useful method inpatients with Fibromyalgia (FM. Additionally, we evaluated QT parameters (QT maximum,QT minimum and QT dispertion with the use of electrocardiography in order to measure theautonomic dysfunction which is a possible mechanism in the pathogenesis of the disease. Methods: The study was performed on 42 patients (mean age 41 years, 38 female and 38completely healthy subjects (35 female, mean age of 42 years who were admitted to the sameclinic were collected as the control group. All the individuals were undergone a completephysical examination, electrocardiography (recordings were displayed at 50 mm/s speed andechocardiography evaluation (both conventional methods and TDE.Results: Analysis of electrocardiographic recordings revealed mildly increased mean QTdispertion in the patient group, but this difference was statistically insignificant. Analysis ofconventional echocardiographic parameters revealed similar results between the patient groupand the control cases. However, an important finding of this study is that significant diastolicdysfunction was found in the patient group which was recorded with the TDE technique. Emwave velocity and Em/Am ratios were significantly lower in patients with FM compared withcontrols (p<0.005, p<0.01, respectively. Sm and Am waves velocities were similar in bothgroups. Conclusion: In this study, significant left ventricular diastolic dysfunction which was detectedby TDE technique can partly explain several symptoms such as fatigue and dyspnea in FM. Inaddition, fully cardiac evaluation of patients with FM might be obtained supporting findingsthe autonomic dysfunction theory in fibromyalgia pathogenesis.

  20. Object Knowledge Modulates Colour Appearance

    Directory of Open Access Journals (Sweden)

    Christoph Witzel

    2011-01-01

    Full Text Available We investigated the memory colour effect for colour diagnostic artificial objects. Since knowledge about these objects and their colours has been learned in everyday life, these stimuli allow the investigation of the influence of acquired object knowledge on colour appearance. These investigations are relevant for questions about how object and colour information in high-level vision interact as well as for research about the influence of learning and experience on perception in general. In order to identify suitable artificial objects, we developed a reaction time paradigm that measures (subjective colour diagnosticity. In the main experiment, participants adjusted sixteen such objects to their typical colour as well as to grey. If the achromatic object appears in its typical colour, then participants should adjust it to the opponent colour in order to subjectively perceive it as grey. We found that knowledge about the typical colour influences the colour appearance of artificial objects. This effect was particularly strong along the daylight axis.

  1. Object knowledge modulates colour appearance

    Science.gov (United States)

    Witzel, Christoph; Valkova, Hanna; Hansen, Thorsten; Gegenfurtner, Karl R

    2011-01-01

    We investigated the memory colour effect for colour diagnostic artificial objects. Since knowledge about these objects and their colours has been learned in everyday life, these stimuli allow the investigation of the influence of acquired object knowledge on colour appearance. These investigations are relevant for questions about how object and colour information in high-level vision interact as well as for research about the influence of learning and experience on perception in general. In order to identify suitable artificial objects, we developed a reaction time paradigm that measures (subjective) colour diagnosticity. In the main experiment, participants adjusted sixteen such objects to their typical colour as well as to grey. If the achromatic object appears in its typical colour, then participants should adjust it to the opponent colour in order to subjectively perceive it as grey. We found that knowledge about the typical colour influences the colour appearance of artificial objects. This effect was particularly strong along the daylight axis. PMID:23145224

  2. Hypersensitivity reactions to food colours with special reference to the natural colour annatto extract (butter colour).

    Science.gov (United States)

    Mikkelsen, H; Larsen, J C; Tarding, F

    1978-01-01

    It is well known that synthetic food colours especially some azo dyes can provoke hypersensitivity reactions such as urticaria, angioneurotic oedema, and astma (Michaëlsson and Juhlin, 1973, Granholt and Thune, 1975). Natural food colours are scarcely investigated with respect to potential allergic properties. Annatto extract, a commonly used food colour in edible fats e.g. butter, has been tested in patients. Among 61 consecutive patients suffereing from chornic urticaria and/or angioneurotic oedema 56 patients were orally provoked by annatto extract during elimination diet. Challenge was performed with a dose equivalent to the amount used in 25 grammes of butter. Twentysix per cent of the patients reacted to this colour 4 hours (SD: 2,6) after intake. Similar challenges with synthetic dyes showed the following results: Tartrazine 11%, Sunset Yellow FCF 17%, Food Red 17 16%, Amaranth 9%, Ponceau 4 R 15%, Erythrosine 12% and Brillant Blue FCF 14%. The present study indicates that natural food colours may induce hypersensitivity reactions as frequent as synthetic dyes.

  3. Optimal colour quality of LED clusters based on memory colours.

    Science.gov (United States)

    Smet, Kevin; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2011-03-28

    The spectral power distributions of tri- and tetrachromatic clusters of Light-Emitting-Diodes, composed of simulated and commercially available LEDs, were optimized with a genetic algorithm to maximize the luminous efficacy of radiation and the colour quality as assessed by the memory colour quality metric developed by the authors. The trade-off of the colour quality as assessed by the memory colour metric and the luminous efficacy of radiation was investigated by calculating the Pareto optimal front using the NSGA-II genetic algorithm. Optimal peak wavelengths and spectral widths of the LEDs were derived, and over half of them were found to be close to Thornton's prime colours. The Pareto optimal fronts of real LED clusters were always found to be smaller than those of the simulated clusters. The effect of binning on designing a real LED cluster was investigated and was found to be quite large. Finally, a real LED cluster of commercially available AlGaInP, InGaN and phosphor white LEDs was optimized to obtain a higher score on memory colour quality scale than its corresponding CIE reference illuminant.

  4. Cadmium colours: composition and properties

    International Nuclear Information System (INIS)

    Paulus, J.; Knuutinen, U.

    2004-01-01

    The composition and the properties of cadmium aquarelle colours are discussed. The examined colours were 24 different aquarelle cadmium colours from six different manufacturers. The colours ranged from light, bright yellows to dark, deep-red tones. The aim of this research was to find out if the pigments contain cadmium salts: sulphides and/or selenides. This information will help in choosing watercolours in conservation processes. Today, aquarelle colours not containing cadmium pigments are being sold as cadmium colours; thus their properties might be different from actual cadmium colours. The aim of the research was to verify that the colour samples contained cadmium pigments and to estimate their compositions and ageing properties. Element analyses were performed from colour samples using micro-chemical tests and X-ray fluorescence measurements. Thin-layer chromatography was used for analysing gum Arabic as a possible binding medium in the chosen colour samples. Through ageing tests, the resistance of the colour samples to the exposure to light, heat and humidity was studied. Visible-light spectroscopy was used in determining the hues and hue changes of the aquarelle colour samples. The spectrophotometer used the CIE L * a * b * tone colour measuring system. From the colour measurements the changes in the lightness/darkness, the redness, the yellowness and the saturation of the samples were examined. (orig.)

  5. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  6. Right Ventricular Doppler Echocardiographic Study of Indeterminate Form of Chagas Disease

    Directory of Open Access Journals (Sweden)

    Rogério Gomes Furtado

    2015-03-01

    Full Text Available Background: Patients with indeterminate form of Chagas disease/cardiac normality (ICD/CN exhibited normal electrocardiograms and chest X-rays; however, more sophisticated tests detected some degree of morphological and functional changes in the heart. Objective: To assess the prevalence of systolic and diastolic dysfunction of the right ventricle (RV in patients with ICD/CN. Methods: This was a case–control and prevalence study. Using Doppler two-dimensional echocardiography (2D, 92 patients were assessed and divided into two groups: group I (normal, n = 31 and group II (ICD/CN, n = 61. Results: The prevalence of RV systolic dysfunction in patients in groups I and II was as follows: fractional area change (0.0% versus 0.6%, mobility of the tricuspid annulus (0.0% versus 0.0%, and S-wave tissue Doppler (6.4% versus 26.0%, p = 0.016. The prevalence of global disorders such as the right myocardial performance index using tissue Doppler (16.1% versus 27.8%, p = 0.099 and pulsed Doppler (61.3% versus 68%, p = 0.141 and diastolic disorders such as abnormal relaxation (0.0% versus 6.0%, pseudonormal pattern (0.0% versus 0.0%, and restrictive pattern (0.0% versus 0.0% was not statistically different between groups. Conclusion: The prevalence of RV systolic dysfunction was estimated to be 26% (S wave velocity compared with other variables, suggesting incipient changes in RV systolic function in the ICD/CN group.

  7. Design of an integrated photo detector circuit for laser doppler blood flow monitoring

    NARCIS (Netherlands)

    Nieland, J.; Nieland, J.; van Kranenburg, H.; Wallinga, Hans; Serov, Alexander; Steenbergen, Wiendelt; de Mul, F.F.M.

    1999-01-01

    A method to measure the blood perfusion of tissue is to apply photons to tissue and measure the frequency shift of the Doppler shifted photons.. To avoid the use of fibers, a chip was designed which contains photodetectors and electronic circuitry to amplify the signal. This IC serves as an

  8. Colour categories are reflected in sensory stages of colour perception when stimulus issues are resolved

    Science.gov (United States)

    He, Xun; Franklin, Anna

    2017-01-01

    Debate exists about the time course of the effect of colour categories on visual processing. We investigated the effect of colour categories for two groups who differed in whether they categorised a blue-green boundary colour as the same- or different-category to a reliably-named blue colour and a reliably-named green colour. Colour differences were equated in just-noticeable differences to be equally discriminable. We analysed event-related potentials for these colours elicited on a passive visual oddball task and investigated the time course of categorical effects on colour processing. Support for category effects was found 100 ms after stimulus onset, and over frontal sites around 250 ms, suggesting that colour naming affects both early sensory and later stages of chromatic processing. PMID:28542426

  9. Minimum Colour Differences Required To Recognise Small Objects On A Colour CRT

    Science.gov (United States)

    Phillips, Peter L.

    1985-05-01

    Data is required to assist in the assessment, evaluation and optimisation of colour and other displays for both military and general use. A general aim is to develop a mathematical technique to aid optimisation and reduce the amount of expensive hardware development and trials necessary when introducing new displays. The present standards and methods available for evaluating colour differences are known not to apply to the perception of typical objects on a display. Data is required for irregular objects viewed at small angular subtense ((1°) and relating the recognition of form rather than colour matching. Therefore laboratory experiments have been carried out using a computer controlled CRT to measure the threshold colour difference that an observer requires between object and background so that he can discriminate a variety of similar objects. Measurements are included for a variety of background and object colourings. The results are presented in the CIE colorimetric system similar to current standards used by the display engineer. Apart from the characteristic small field tritanopia, the results show that larger colour differences are required for object recognition than those assumed from conventional colour discrimination data. A simple relationship to account for object size and background colour is suggested to aid visual performance assessments and modelling.

  10. Put on that colour, it fits your emotion: Colour appropriateness as a function of expressed emotion.

    Science.gov (United States)

    Dael, Nele; Perseguers, Marie-Noëlle; Marchand, Cynthia; Antonietti, Jean-Philippe; Mohr, Christine

    2016-01-01

    People associate affective meaning with colour, and this may influence decisions about colours. Hue is traditionally considered the most salient descriptor of colour and colour-affect associations, although colour brightness and saturation seem to have particularly strong affective connotations. To test whether colour choices can be driven by emotion, we investigated whether and how colour hue, brightness, and saturation are systematically associated with bodily expressions of positive (joy) and negative (fear) emotions. Twenty-five non-colour-blind participants viewed videos of these expressions and selected for each video the most appropriate colour using colour sliders providing values for hue, brightness, and saturation. The overall colour choices were congruent with the expressed emotion--that is, participants selected brighter and more saturated colours for joy expressions than for fear expressions. Also, colours along the red-yellow spectrum were deemed more appropriate for joy expressions and cyan-bluish hues for fear expressions. The current study adds further support to the role of emotion in colour choices by (a) showing that emotional information is spontaneously used in an unconstrained choice setting, (b) extending to ecologically valid stimuli occurring in everyday encounters (dressed bodies), and (c) suggesting that all colour parameters are likely to be important when processing affective nonverbal person information, though not independently from each other.

  11. Assessment of portal venous system patency in the liver transplant candidate: A prospective study comparing ultrasound, microbubble-enhanced colour Doppler ultrasound, with arteriography and surgery

    International Nuclear Information System (INIS)

    Marshall, M.M.; Beese, R.C.; Muiesan, P.; Sarma, D.I.; O'Grady, J.; Sidhu, P.S.

    2002-01-01

    AIM: To determine the role of microbubble-enhanced colour Doppler ultrasound (CDUS) in assessing portal venous patency prior to liver transplantation. MATERIALS AND METHODS: Over a 2-year period, all patients with chronic liver disease undergoing routine pre-transplant CDUS examination in whom the portal venous system was inadequately demonstrated were recruited to the study. CDUS was performed in 368 patients and 33 patients (9%) were recruited. A repeat CDUS examination following an intravenous bolus injection of the microbubble contrast agent Levovist[reg] (Schering Healthcare AG, Berlin, Germany) was performed. Diagnostic confidence was recorded on a free linear analogue scale for both examinations. Findings were compared with indirect portography and surgery. RESULTS: Of the 33 patients with sub-optimal baseline examinations, improvement in portal vein visualization was achieved in 31 patients (94%). Median diagnostic confidence increased from 50% (interquartile range 30-60) to 90% (interquartile range 75-98) (P < 0.001) following administration of Levovist[reg]. Overall accuracy of portal vein assessment using microbubble-enhanced CDUS in 15 patients in whom a definitive diagnosis was made within 2 months was 87%. CONCLUSION: Microbubble-enhanced CDUS is a simple, inexpensive adjunct to standard pre liver transplant screening of the portal vein. It is particularly helpful in patients with end-stage cirrhosis who are at high risk of portal vein thrombosis and in whom the conventional examination is sub-optimal.Marshall, M.M. et al. (2002)

  12. Production of an anthocyanin-rich food colourant from Thymus moroderi and its application in foods.

    Science.gov (United States)

    Díaz-García, Miriam Cristina; Castellar, María Rosario; Obón, José María; Obón, Concepción; Alcaraz, Francisco; Rivera, Diego

    2015-04-01

    Anthocyanins and other polyphenols from flowers and bracts of Thymus sp. are studied. An anthocyanin-rich food colourant with interesting high antioxidant activity from Thymus moroderi has been obtained, and applied to colour foods. Anthocyanins and other polyphenols from T. moroderi and another five Thymus sp. were extracted in methanol/hydrochloric acid 0.1 mol L(-1) (50/50, v/v) 2 h stirring at 50 °C. They were identified and quantified by HPLC-PDA-MS and UHPLC-PDA-fluorescence, as total individual polyphenols. Total polyphenols were also determined. Flowers had higher anthocyanins and other polyphenols concentrations than bracts; for example, total polyphenols content of T. moroderi were 131.58 and 61.98 g GAE kg(-1) vegetal tissue, respectively. A liquid concentrated colourant was obtained from T. moroderi using water/citric acid as solvent. It was characterised and compared with other two commercial anthocyanin-rich food colourants from red grape skin and red carrot (colour strength of 1.7 and 3.6 AU, respectively). T. moroderi colourant had 1.2 AU colour strength, and high storage stability (>97.1% remaining colour after 110 days at 4 °C). It showed a higher polyphenols content than commercial colourants. Its antioxidant activity was 0.707 mmol Trolox eq. g(-1) plant dry weight, 69.5 times higher than red carrot. The three colourants were applied to colour yogurts, giving pinky tonalities. The colour did not change evidently (ΔE*(ab)  antioxidant activity. This colourant gives a stable colour to a yogurt during 1 month. These results expand the use of natural colourants. © 2014 Society of Chemical Industry.

  13. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  14. The control of attentional target selection in a colour/colour conjunction task

    OpenAIRE

    Berggren, Nick; Eimer, Martin

    2016-01-01

    To investigate the time course of attentional object selection processes in visual search tasks where targets are defined by a combination of features from the same dimension, we measured the N2pc component as an electrophysiological marker of attentional object selection during colour/colour conjunction search. In Experiment 1, participants searched for targets defined by a combination of two colours, while ignoring distractor objects that matched only one of these colours. Reliable N2pc com...

  15. An example of applied colour vision research: the conspicuity of airplane colour

    NARCIS (Netherlands)

    Lucassen, M.P.

    2002-01-01

    This paper describes the application of the combined knowledge on colorimetry, colour imaging (visualization) and colour perception in an aviation related research project. It involves the optimisation of the conspicuity of the colour scheme of an airplane, with the purpose of minimizing the changes

  16. Most and Least Preferred Colours Differ According to Object Context: New Insights from an Unrestricted Colour Range.

    Science.gov (United States)

    Jonauskaite, Domicele; Mohr, Christine; Antonietti, Jean-Philippe; Spiers, Peter M; Althaus, Betty; Anil, Selin; Dael, Nele

    2016-01-01

    Humans like some colours and dislike others, but which particular colours and why remains to be understood. Empirical studies on colour preferences generally targeted most preferred colours, but rarely least preferred (disliked) colours. In addition, findings are often based on general colour preferences leaving open the question whether results generalise to specific objects. Here, 88 participants selected the colours they preferred most and least for three context conditions (general, interior walls, t-shirt) using a high-precision colour picker. Participants also indicated whether they associated their colour choice to a valenced object or concept. The chosen colours varied widely between individuals and contexts and so did the reasons for their choices. Consistent patterns also emerged, as most preferred colours in general were more chromatic, while for walls they were lighter and for t-shirts they were darker and less chromatic compared to least preferred colours. This meant that general colour preferences could not explain object specific colour preferences. Measures of the selection process further revealed that, compared to most preferred colours, least preferred colours were chosen more quickly and were less often linked to valenced objects or concepts. The high intra- and inter-individual variability in this and previous reports furthers our understanding that colour preferences are determined by subjective experiences and that most and least preferred colours are not processed equally.

  17. Most and Least Preferred Colours Differ According to Object Context: New Insights from an Unrestricted Colour Range.

    Directory of Open Access Journals (Sweden)

    Domicele Jonauskaite

    Full Text Available Humans like some colours and dislike others, but which particular colours and why remains to be understood. Empirical studies on colour preferences generally targeted most preferred colours, but rarely least preferred (disliked colours. In addition, findings are often based on general colour preferences leaving open the question whether results generalise to specific objects. Here, 88 participants selected the colours they preferred most and least for three context conditions (general, interior walls, t-shirt using a high-precision colour picker. Participants also indicated whether they associated their colour choice to a valenced object or concept. The chosen colours varied widely between individuals and contexts and so did the reasons for their choices. Consistent patterns also emerged, as most preferred colours in general were more chromatic, while for walls they were lighter and for t-shirts they were darker and less chromatic compared to least preferred colours. This meant that general colour preferences could not explain object specific colour preferences. Measures of the selection process further revealed that, compared to most preferred colours, least preferred colours were chosen more quickly and were less often linked to valenced objects or concepts. The high intra- and inter-individual variability in this and previous reports furthers our understanding that colour preferences are determined by subjective experiences and that most and least preferred colours are not processed equally.

  18. Most and Least Preferred Colours Differ According to Object Context: New Insights from an Unrestricted Colour Range

    Science.gov (United States)

    Jonauskaite, Domicele; Mohr, Christine; Antonietti, Jean-Philippe; Spiers, Peter M.; Althaus, Betty; Anil, Selin; Dael, Nele

    2016-01-01

    Humans like some colours and dislike others, but which particular colours and why remains to be understood. Empirical studies on colour preferences generally targeted most preferred colours, but rarely least preferred (disliked) colours. In addition, findings are often based on general colour preferences leaving open the question whether results generalise to specific objects. Here, 88 participants selected the colours they preferred most and least for three context conditions (general, interior walls, t-shirt) using a high-precision colour picker. Participants also indicated whether they associated their colour choice to a valenced object or concept. The chosen colours varied widely between individuals and contexts and so did the reasons for their choices. Consistent patterns also emerged, as most preferred colours in general were more chromatic, while for walls they were lighter and for t-shirts they were darker and less chromatic compared to least preferred colours. This meant that general colour preferences could not explain object specific colour preferences. Measures of the selection process further revealed that, compared to most preferred colours, least preferred colours were chosen more quickly and were less often linked to valenced objects or concepts. The high intra- and inter-individual variability in this and previous reports furthers our understanding that colour preferences are determined by subjective experiences and that most and least preferred colours are not processed equally. PMID:27022909

  19. Colour-Temperature Correspondences: When Reactions to Thermal Stimuli Are Influenced by Colour

    Science.gov (United States)

    Ho, Hsin-Ni; Van Doorn, George H.; Kawabe, Takahiro; Watanabe, Junji; Spence, Charles

    2014-01-01

    In our daily lives, information concerning temperature is often provided by means of colour cues, with red typically being associated with warm/hot, and blue with cold. While such correspondences have been known about for many years, they have primarily been studied using subjective report measures. Here we examined this correspondence using two more objective response measures. First, we used the Implicit Association Test (IAT), a test designed to assess the strength of automatic associations between different concepts in a given individual. Second, we used a priming task that involved speeded target discrimination in order to assess whether priming colour or thermal information could invoke the crossmodal association. The results of the IAT confirmed that the association exists at the level of response selection, thus indicating that a participant’s responses to colour or thermal stimuli are influenced by the colour-temperature correspondence. The results of the priming experiment revealed that priming a colour affected thermal discrimination reaction times (RTs), but thermal cues did not influence colour discrimination responses. These results may therefore provide important clues as to the level of processing at which such colour-temperature correspondences are represented. PMID:24618675

  20. Computational colour science using MATLAB

    CERN Document Server

    Westland, Stephen; Cheung, Vien

    2012-01-01

    Computational Colour Science Using MATLAB 2nd Edition offers a practical, problem-based approach to colour physics. The book focuses on the key issues encountered in modern colour engineering, including efficient representation of colour information, Fourier analysis of reflectance spectra and advanced colorimetric computation. Emphasis is placed on the practical applications rather than the techniques themselves, with material structured around key topics. These topics include colour calibration of visual displays, computer recipe prediction and models for colour-appearance prediction. Each t

  1. About Coloured Cold Asphaltic Mixtures

    Directory of Open Access Journals (Sweden)

    Loredana Judele

    2008-01-01

    Full Text Available The first coloured bitumen was obtained by using bitumen from Peru and then bitumen from the Middle East, with a low content of asphaltenes, also called "colourable" bitumens. The colours obtained by adding iron oxides led nevertheless to dark colours, due to the presence of asphaltenes. Nowadays the coloured asphalt is obtained from synthesis binders with translucent aspect. The colours are obtained by adding inorganic pigments, mainly iron oxide for red, chromic oxide for green, titanic dioxide for white. The properties and behaviour of the coloured bitumen during its lifetime are comparable with the ones of classic bitumen, sometimes even better.

  2. Topographical coloured plasmonic coins

    OpenAIRE

    Guay, Jean-Michel; Lesina, Antonino Calà; Côté, Guillaume; Charron, Martin; Ramunno, Lora; Berini, Pierre; Weck, Arnaud

    2016-01-01

    Plasmonic resonances in metallic nanoparticles have been used since antiquity to colour glasses. The use of metal nanostructures for surface colourization has attracted considerable interest following recent developments in plasmonics. However, current top-down colourization methods are not ideally suited to large-scale industrial applications. Here we use a bottom-up approach where picosecond laser pulses can produce a full palette of non-iridescent colours on silver, gold, copper and alumin...

  3. Molluscan shell colour.

    Science.gov (United States)

    Williams, Suzanne T

    2017-05-01

    The phylum Mollusca is highly speciose, and is the largest phylum in the marine realm. The great majority of molluscs are shelled, including nearly all bivalves, most gastropods and some cephalopods. The fabulous and diverse colours and patterns of molluscan shells are widely recognised and have been appreciated for hundreds of years by collectors and scientists alike. They serve taxonomists as characters that can be used to recognise and distinguish species, however their function for the animal is sometimes less clear and has been the focus of many ecological and evolutionary studies. Despite these studies, almost nothing is known about the evolution of colour in molluscan shells. This review summarises for the first time major findings of disparate studies relevant to the evolution of shell colour in Mollusca and discusses the importance of colour, including the effects of visual and non-visual selection, diet and abiotic factors. I also summarise the evidence for the heritability of shell colour in some taxa and recent efforts to understand the molecular mechanisms underpinning synthesis of shell colours. I describe some of the main shell pigments found in Mollusca (carotenoids, melanin and tetrapyrroles, including porphyrins and bile pigments), and their durability in the fossil record. Finally I suggest that pigments appear to be distributed in a phylogenetically relevant manner and that the synthesis of colour is likely to be energetically costly. © 2016 Cambridge Philosophical Society.

  4. Tissue Doppler imaging of carotid plaque wall motion: a pilot study

    Directory of Open Access Journals (Sweden)

    Naylor A Ross

    2003-12-01

    Full Text Available Abstract Background Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI of Arterial Wall Motion (AWM and to quantify simple wall motion indices in normal and diseased carotid arteries. Methods 224 normal and diseased carotid arteries (0–100% stenoses were imaged in 126 patients (age 25–88 years, mean 68 ± 11. Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. Results AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. Conclusion Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI.

  5. Doppler echocardiographic predictors of mortality in female rats after myocardial infarction.

    Science.gov (United States)

    Santos, Alexandra Alberta; Helber, Izzo; Flumignan, Ronald L G; Antonio, Ednei L; Carvalho, Antonio C; Paola, Angelo A; Tucci, Paulo J; Moises, Valdir A

    2009-03-01

    Doppler echocardiogram is useful for the evaluation of anatomical and functional changes in late myocardial infarction (MI) in rats. However, no studies have evaluated the prognostic value of echocardiographic parameters 1 week after MI. Doppler echocardiogram was performed in 84 female Wistar rats 1 week after MI to determine infarction size, left chambers dimensions, fractional area change (FAC) of the left ventricle (LV), mitral inflow and tissue Doppler, myocardial performance index (MPI), and signs of pulmonary hypertension. The 365-day follow-up showed 53.6% mortality rate. Nonsurvivors showed larger (P or=0.60 (RR 3.49, 95% CI, 1.80-6.76), LV systolic area >or=0.26 cm(2) (RR 4.38, 95% CI, 1.88-10.21), E/E' ratio >or=20.3 (RR 2.12, 95% CI, 1.15-4.34), and E/A ratio associated with FAC (RR 2.99, 95% CI, 1.44-6.18). Some diastolic and systolic Doppler echocardiographic parameters in rats may be able to predict late mortality risk after MI.

  6. The influence of the microscope lamp filament colour temperature on the process of digital images of histological slides acquisition standardization.

    Science.gov (United States)

    Korzynska, Anna; Roszkowiak, Lukasz; Pijanowska, Dorota; Kozlowski, Wojciech; Markiewicz, Tomasz

    2014-01-01

    The aim of this study is to compare the digital images of the tissue biopsy captured with optical microscope using bright field technique under various light conditions. The range of colour's variation in immunohistochemically stained with 3,3'-Diaminobenzidine and Haematoxylin tissue samples is immense and coming from various sources. One of them is inadequate setting of camera's white balance to microscope's light colour temperature. Although this type of error can be easily handled during the stage of image acquisition, it can be eliminated with use of colour adjustment algorithms. The examination of the dependence of colour variation from microscope's light temperature and settings of the camera is done as an introductory research to the process of automatic colour standardization. Six fields of view with empty space among the tissue samples have been selected for analysis. Each field of view has been acquired 225 times with various microscope light temperature and camera white balance settings. The fourteen randomly chosen images have been corrected and compared, with the reference image, by the following methods: Mean Square Error, Structural SIMilarity and visual assessment of viewer. For two types of backgrounds and two types of objects, the statistical image descriptors: range, median, mean and its standard deviation of chromaticity on a and b channels from CIELab colour space, and luminance L, and local colour variability for objects' specific area have been calculated. The results have been averaged for 6 images acquired in the same light conditions and camera settings for each sample. The analysis of the results leads to the following conclusions: (1) the images collected with white balance setting adjusted to light colour temperature clusters in certain area of chromatic space, (2) the process of white balance correction for images collected with white balance camera settings not matched to the light temperature moves image descriptors into proper

  7. Colour for Behavioural Success

    Science.gov (United States)

    Reeves, Adam

    2018-01-01

    Colour information not only helps sustain the survival of animal species by guiding sexual selection and foraging behaviour but also is an important factor in the cultural and technological development of our own species. This is illustrated by examples from the visual arts and from state-of-the-art imaging technology, where the strategic use of colour has become a powerful tool for guiding the planning and execution of interventional procedures. The functional role of colour information in terms of its potential benefits to behavioural success across the species is addressed in the introduction here to clarify why colour perception may have evolved to generate behavioural success. It is argued that evolutionary and environmental pressures influence not only colour trait production in the different species but also their ability to process and exploit colour information for goal-specific purposes. We then leap straight to the human primate with insight from current research on the facilitating role of colour cues on performance training with precision technology for image-guided surgical planning and intervention. It is shown that local colour cues in two-dimensional images generated by a surgical fisheye camera help individuals become more precise rapidly across a limited number of trial sets in simulator training for specific manual gestures with a tool. This facilitating effect of a local colour cue on performance evolution in a video-controlled simulator (pick-and-place) task can be explained in terms of colour-based figure-ground segregation facilitating attention to local image parts when more than two layers of subjective surface depth are present, as in all natural and surgical images. PMID:29770183

  8. Bumblebees (Bombus terrestris) and honeybees (Apis mellifera) prefer similar colours of higher spectral purity over trained colours.

    Science.gov (United States)

    Rohde, Katja; Papiorek, Sarah; Lunau, Klaus

    2013-03-01

    Differences in the concentration of pigments as well as their composition and spatial arrangement cause intraspecific variation in the spectral signature of flowers. Known colour preferences and requirements for flower-constant foraging bees predict different responses to colour variability. In experimental settings, we simulated small variations of unicoloured petals and variations in the spatial arrangement of colours within tricoloured petals using artificial flowers and studied their impact on the colour choices of bumblebees and honeybees. Workers were trained to artificial flowers of a given colour and then given the simultaneous choice between three test colours: either the training colour, one colour of lower and one of higher spectral purity, or the training colour, one colour of lower and one of higher dominant wavelength; in all cases the perceptual contrast between the training colour and the additional test colours was similarly small. Bees preferred artificial test flowers which resembled the training colour with the exception that they preferred test colours with higher spectral purity over trained colours. Testing the behaviour of bees at artificial flowers displaying a centripetal or centrifugal arrangement of three equally sized colours with small differences in spectral purity, bees did not prefer any type of artificial flowers, but preferentially choose the most spectrally pure area for the first antenna contact at both types of artificial flowers. Our results indicate that innate preferences for flower colours of high spectral purity in pollinators might exert selective pressure on the evolution of flower colours.

  9. Pulsed-wave tissue Doppler imaging of the myocardium of cats with induced thyrotoxicosis Doppler tecidual pulsado do miocárdio de gatos com tirotoxicose induzida

    Directory of Open Access Journals (Sweden)

    Daniel Capucho de Oliveira

    2011-06-01

    Full Text Available Left ventricular myocardial motion was quantified using pulsed-wave tissue Doppler imaging (PW-TDI in nine adult cats before and after thyrotoxicosis induction. In order to induce thyrotoxicosis, all cats were given 150µg kg-1 of levothyroxine sodium as a single oral dose each day for 10 weeks. PW-TDI examinations were performed immediately before the induction and by the end of the experimental protocol. An increase in myocardial motion velocity was documented at the interventricular septum level, demonstrated by an elevation in systolic (Sa, and early (Ea and late (Aa diastolic waves (PA velocidade de movimentação miocárdica do ventrículo esquerdo foi quantificada por meio de exames ecocardiográficos com Doppler tecidual pulsado (PW-TDI em nove gatos adultos antes e após indução à tirotoxicose. Para indução da tirotoxicose, todos os gatos receberam doses diárias de 150mg kg-1 de levotiroxina sódica, por via oral, durante 10 semanas. Os exames de PW-TDI foram realizados imediatamente antes da indução e ao final do protocolo experimental. Uma elevação na velocidade de movimentação miocárdica foi documentada ao nível do septo interventricular, demonstrado por um aumento das ondas sistólica (Sa e diastólicas (Ea e Aa; P<0,05. No entanto, nenhuma alteração nos valores de Sa, Ea e Aa foi encontrada ao nível da parede livre do ventrículo esquerdo. A frequência cardíaca aumentou significativamente entre os momentos experimentais, sendo que três animais apresentaram fusão das ondas Aa e Ea ao final do experimento. O protocolo experimental utilizado neste estudo causou alterações na velocidade de movimentação do miocárdio ventricular esquerdo, mas sem causar danos à função diastólica do ventrículo esquerdo.

  10. Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major.

    Science.gov (United States)

    Saravi, Mehrdad; Tamadoni, Ahmad; Jalalian, Rozita; Mahmoodi-Nesheli, Hassan; Hojati, Mosatafa; Ramezani, Saeed

    2013-01-01

    Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard non-invasive diagnostic test. A total of 100 TM patients with the mean age of 19±7 years and 100 healthy controls 18.8±7 years were evaluated. Conventional echocardiography, TDI, and cardiac MRI T2* were performed in all subjects. TDI measures included myocardial systolic (Sm), early (Em) and late (Am) diastolic velocities at basal and middle segments of septal and lateral LV wall. The TM patients were also subgrouped according to those with iron load (T2* ≤ 20 ms) and those without (T2* > 20 ms), and also severe (T2* ≤ 10 ms) versus the non-severe (T2* ≤ 10 ms). Using T2* cardiovascular MR, abnormal myocardial iron load (T2* ≤ 20 ms) was detected in 84% of the patients and among these, 50% (42/84) had severe (T2* ≤ 10 ms) iron load. The mean T2* was 11.6±8.6 ms (5-36.7). A negative linear correlation existed between transfusion period of patients and T2* levels (r = -0.53, p=0.02). The following TDI measures were lower in patients than in controls: basal septal Am (p<0.05), mid-septal Em and Am (p<0.05), basal lateral Am (p<0.05), mid-lateral LV wall Sm (p<0.05) and Am (p<0.05). Tissue doppler imaging is helpful in predicting the presence of myocardial iron load in Thalassemia patients. Therefore, it can be used for screening of thalassemia major patients.

  11. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  12. The handicap of abnormal colour vision.

    Science.gov (United States)

    Cole, Barry L

    2004-07-01

    All people with abnormal colour vision, except for a few mildly affected deuteranomals, report that they experience problems with colour in everyday life and at work. Contemporary society presents them with increasing problems because colour is now so widely used in printed materials and in computer displays. Equal opportunity law gives them protection against unfair discrimination in employment, so a decision to exclude a person from employment on the grounds of abnormal colour vision must now be well supported by good evidence and sound argument. This paper reviews the investigations that have contributed to understanding the nature and consequences of the problems they have. All those with abnormal colour vision are at a disadvantage with comparative colour tasks that involve precise matching of colours or discrimination of fine colour differences either because of their loss of colour discrimination or anomalous perception of metamers. The majority have problems when colour is used to code information, in man-made colour codes and in naturally occurring colour codes that signal ripeness of fruit, freshness of meat or illness. They can be denied the benefit of colour to mark out objects and organise complex visual displays. They may be unreliable when a colour name is used as an identifier. They are slower and less successful in search when colour is an attribute of the target object or is used to organise the visual display. Because those with the more severe forms of abnormal colour vision perceive a very limited gamut of colours, they are at a disadvantage in the pursuit and appreciation of those forms of art that use colour.

  13. Specific deficit of colour-colour short-term memory binding in sporadic and familial Alzheimer's disease.

    Science.gov (United States)

    Parra, Mario A; Sala, Sergio Della; Abrahams, Sharon; Logie, Robert H; Méndez, Luis Guillermo; Lopera, Francisco

    2011-06-01

    Short-term memory binding of visual features which are processed across different dimensions (shape-colour) is impaired in sporadic Alzheimer's disease, familial Alzheimer's disease, and in asymptomatic carriers of familial Alzheimer's disease. This study investigated whether Alzheimer's disease also impacts on within-dimension binding processes. The study specifically explored whether visual short-term memory binding of features of the same type (colour-colour) is sensitive to Alzheimer's disease. We used a neuropsychological battery and a short-term memory binding task to assess patients with sporadic Alzheimer's disease (Experiment 1), familial Alzheimer's disease (Experiment 2) due to the mutation E280A of the Presenilin-1 gene and asymptomatic carriers of the mutation. The binding task assessed change detection within arrays of unicoloured objects (Colour Only) or bicoloured objects the colours of which had to be remembered separately (Unbound Colours) or together (Bound Colours). Performance on the Bound Colours condition (1) explained the largest proportion of variance between patients (sporadic and familial Alzheimer's disease), (2) combined more sensitivity and specificity for the disease than other more traditional neuropsychological tasks, (3) identified asymptomatic carriers of the mutation even when traditional neuropsychological measures and other measures of short-term memory did not and, (4) contrary to shape-colour binding, correlated with measures of hippocampal functions. Colour-colour binding and shape-colour binding both appear to be sensitive to AD even though they seem to rely on different brain mechanisms. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  15. Value of Predicting Pregnant Hypertension of Observing PI and RI of Placental Helicine Arteries by Colour Doppler%彩色多普勒检测孕妇子宫胎盘床螺旋动脉PI、RI预测妊高征价值

    Institute of Scientific and Technical Information of China (English)

    茅红卫; 凡利俊; 季平; 张新源

    2001-01-01

    目的本研究采用彩色多普勒检测孕妇子宫胎盘床螺旋动脉搏动指数(PI),阻力指数(RI),预测妊高征的发生、发展及预后。方法选择无慢性高血压,心、肝、肾合并症正常孕妇184例。分正常组154例,异常组30例。从孕32周开始每隔2~3周重复检测一次子宫胎盘床螺旋动脉PI、RI,测量5个以上形态一致的多普勒频谱,取平均PI、RI值。结果两组存在显著差异,异常组PI、RI明显高于正常组(P<0.01)。结论应用彩色多普勒测定子宫胎盘床螺旋动脉PI、RI来预测孕高征的发生、发展及预后具有临床应用价值。%Objective To observe pulsative index (PI), resistant index (RI) of placental helicine arteries by colour Doppler, analyses relation between PI, RI and developing of pregnant hypertension. Methods There were 184 healthy pregnant women, they were normal in cardial, hepatic, nephral function, without hypertension 154 cases in 184 women were normal pregnant course, but 30 cases were with pregnant hypertension, since 32 pregnant weeks,every 2 or 3 weeks, the arteries were examined, more 5 frequency spectrums with same appearance,average of PI, RI were calculated. Results There are signifiant difference, PI, RI of pregnant hypertension were higher than normal group (P<0.01). Conclusion It is valuable for the clinics to observe helicine arteries by colour Doppler to predict pregnant hypertention.

  16. Search for Colour Singlet and Colour Reconnection Effects in Hadronic Z Decays at LEP

    CERN Document Server

    Achard, P; Aguilar-Benítez, M; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alviggi, M G; Anderhub, H; Andreev, V P; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Bajo, A; Baksay, G; Baksay, L; Baldew, S V; Banerjee, S; Banerjee, Sw; Barczyk, A; Barillère, R; Bartalini, P; Basile, M; Batalova, N; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Bellucci, L; Berbeco, R; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Biasini, M; Biglietti, M; Biland, A; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böhm, A; Boldizsar, L; Borgia, B; Bottai, S; Bourilkov, D; Bourquin, Maurice; Braccini, S; Branson, J G; Brochu, F; Burger, J D; Burger, W J; Cai, X D; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A M; Casaus, J; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada, M; Chamizo-Llatas, M; Chang, Y H; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chiefari, G; Cifarelli, Luisa; Cindolo, F; Clare, I; Clare, R; Coignet, G; Colino, N; Costantini, S; de la Cruz, B; Cucciarelli, S; van Dalen, J A; De Asmundis, R; Déglon, P L; Debreczeni, J; Degré, A; Dehmelt, K; Deiters, K; Della Volpe, D; Delmeire, E; Denes, P; De Notaristefani, F; De Salvo, A; Diemoz, M; Dierckxsens, M; Dionisi, C; Dittmar, M; Doria, A; Dova, M T; Duchesneau, D; Duda, M; Echenard, B; Eline, A; El-Hage, A; El-Mamouni, H; Engler, A; Eppling, F J; Extermann, P; Falagán, M A; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, M; Ferguson, T; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, F; Fisher, P H; Fisher, W; Fisk, I; Forconi, G; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gataullin, M; Gentile, S; Giagu, S; Gong, Z F; Grenier, G; Grimm, O; Grünewald, M W; Guida, M; van Gulik, R; Gupta, V K; Gurtu, A; Gutay, L J; Haas, D; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Hirschfelder, J; Hofer, H; Hohlmann, M; Holzner, G; Hou, S R; Hu, Y; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Käfer, D; Kaur, M; Kienzle-Focacci, M N; Kim, J K; Kirkby, Jasper; Kittel, E W; Klimentov, A; König, A C; Kopal, M; Koutsenko, V F; Kräber, M H; Krämer, R W; Krüger, A; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Le Goff, J M; Leiste, R; Levtchenko, M; Levchenko, P M; Li, C; Likhoded, S; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lü, Y S; Luci, C; Luminari, L; Lustermann, W; Ma Wen Gan; Malgeri, L; Malinin, A; Maña, C; Mans, J; Martin, J P; Marzano, F; Mazumdar, K; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Mihul, A; Milcent, H; Mirabelli, G; Mnich, J; Mohanty, G B; Muanza, G S; Muijs, A J M; Musicar, B; Musy, M; Nagy, S; Natale, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Nisati, A; Novák, T; Nowak, H; Ofierzynski, R A; Organtini, G; Pal, I; Palomares, C; Paolucci, P; Paramatti, R; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Pedace, M; Pensotti, S; Perret-Gallix, D; Petersen, B; Piccolo, D; Pierella, F; Pioppi, M; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Pothier, J; Prokofev, D; Prokofiev, D O; Quartieri, J; Rahal-Callot, G; Rahaman, M A; Raics, P; Raja, N; Ramelli, R; Rancoita, P G; Ranieri, R; Raspereza, A V; Razis, P A; Ren, D; Rescigno, M; Reucroft, S; Riemann, S; Riles, K; Roe, B P; Romero, L; Rosca, A; Rosier-Lees, S; Roth, S; Rosenbleck, C; Rubio, J A; Ruggiero, G; Rykaczewski, H; Sakharov, A; Saremi, S; Sarkar, S; Salicio, J; Sánchez, E; Schäfer, C; Shchegelskii, V; Schopper, Herwig Franz; Schotanus, D J; Sciacca, C; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shumilov, E; Shvorob, A V; Son, D; Souga, C; Spillantini, P; Steuer, M; Stickland, D P; Stoyanov, B; Strässner, A; Sudhakar, K; Sultanov, G G; Sun, L Z; Sushkov, S; Suter, H; Swain, J D; Szillási, Z; Tang, X W; Tarjan, P; Tauscher, Ludwig; Taylor, L; Tellili, B; Teyssier, D; Timmermans, C; Ting, Samuel C C; Ting, S M; Tonwar, S C; Tóth, J; Tully, C; Tung, K L; Ulbricht, J; Valente, E; Van de Walle, R T; Vásquez, R; Veszpremi, V; Vesztergombi, G; Vetlitskii, I; Vicinanza, D; Viertel, Gert M; Villa, S; Vivargent, M; Vlachos, S; Vodopyanov, I; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Wadhwa, M; Wang, Q; Wang, X L; Wang, Z M; Weber, M; Wienemann, P; Wilkens, H; Wynhoff, S; Xia, L; Xu, Z Z; Yamamoto, J; Yang, B Z; Yang, C G; Yang, H J; Yang, M; Yeh, S C; Zalite, A; Zalite, Yu; Zhang, Z P; Zhao, J; Zhu, G Y; Zhu, R Y; Zhuang, H L; Zichichi, A; Zimmermann, B; Zöller, M

    2004-01-01

    A search is performed in symmetric 3-jet hadronic Z decay events for evidence of colour singlet production or colour reconnection effects. Asymmetries in the angular separation of particles are found to be sensitive indicators of such effects. Upper limits on the level of colour singlet production and colour reconnection effects are established for a variety of models.

  17. Colour Reproduction on Tablet Devices

    Directory of Open Access Journals (Sweden)

    Vladimir Zorić

    2014-07-01

    Full Text Available With the advent of Internet and mobile devices client services and other print production are migrating more and more to online platforms. In a recent technology changeover it is obvious that there is growing number of printers as well need from the customers for the print service providers to expand their business to online and mobile platforms. With this technological transition there are some open questions regarding the possibilities of using the tablet devices for colour soft proofing and other colour related operations. As a display devices on a hardware level there are large similarities with the desktop display devices but the operating systems which are driving them are not yet colour smart. There have been some initial attempts to characterize the colour reproduction on this type of devices and find a possibility of using them not just for information content but also for colour managed content. In this study we have tested several tablets (Apple iPad2,Asus Transformer TF101, Samsung Galaxy Tab 1 with different display and OS technology and tested a software which is intended for colour managed viewing of the reproduction. We have measured the colour reproduction of the tablets with the digital version of the GretagMacbeth ColorChecker card and have calculated the colour differences between the colour chart data and the displayed data. We have calibrated the Ipad2 with the only existing colour management tool the Spyder Gallery and we have also tested the chart display with and without the colour correction of the software. We have found that there are differences in the colour reproduction of the display technologies and that the possibilities of a real colour managed workflow has yet to be resolved on the OS level of tablet and mobile devices

  18. In situ monitoring of localized shear stress and fluid flow within developing tissue constructs by Doppler optical coherence tomography

    Science.gov (United States)

    Jia, Yali; Bagnaninchi, Pierre O.; Wang, Ruikang K.

    2008-02-01

    Mechanical stimuli can be introduced to three dimensional (3D) cell cultures by use of perfusion bioreactor. Especially in musculoskeletal tissues, shear stress caused by fluid flow generally increase extra-cellular matrix (ECM) production and cell proliferation. The relationship between the shear stress and the tissue development in situ is complicated because of the non-uniform pore distribution within the cell-seeded scaffold. In this study, we firstly demonstrated that Doppler optical coherence tomography (DOCT) is capable of monitoring localized fluid flow and shear stress in the complex porous scaffold by examining their variation trends at perfusion rate of 5, 8, 10 and 12 ml/hr. Then, we developed the 3D porous cellular constructs, cell-seeded chitosan scaffolds monitored during several days by DOCT. The fiber based fourier domain DOCT employed a 1300 nm superluminescent diode with a bandwidth of 52 nm and a xyz resolution of 20×20×15 μm in free space. This setup allowed us not only to assess the cell growth and ECM deposition by observing their different scattering behaviors but also to further investigate how the cell attachment and ECM production has the effect on the flow shear stress and the relationship between flow rate and shear stress in the developing tissue construct. The possibility to monitor continuously the constructs under perfusion will easily indicate the effect of flow rate or shear stress on the cell viability and cell proliferation, and then discriminate the perfusion parameters affecting the pre-tissue formation rate growth.

  19. Automaticity and localisation of concurrents predicts colour area activity in grapheme-colour synaesthesia.

    Science.gov (United States)

    Gould van Praag, Cassandra D; Garfinkel, Sarah; Ward, Jamie; Bor, Daniel; Seth, Anil K

    2016-07-29

    In grapheme-colour synaesthesia (GCS), the presentation of letters or numbers induces an additional 'concurrent' experience of colour. Early functional MRI (fMRI) investigations of GCS reported activation in colour-selective area V4 during the concurrent experience. However, others have failed to replicate this key finding. We reasoned that individual differences in synaesthetic phenomenology might explain this inconsistency in the literature. To test this hypothesis, we examined fMRI BOLD responses in a group of grapheme-colour synaesthetes (n=20) and matched controls (n=20) while characterising the individual phenomenology of the synaesthetes along dimensions of 'automaticity' and 'localisation'. We used an independent functional localiser to identify colour-selective areas in both groups. Activations in these areas were then assessed during achromatic synaesthesia-inducing, and non-inducing conditions; we also explored whole brain activations, where we sought to replicate the existing literature regarding synaesthesia effects. Controls showed no significant activations in the contrast of inducing > non-inducing synaesthetic stimuli, in colour-selective ROIs or at the whole brain level. In the synaesthete group, we correlated activation within colour-selective ROIs with individual differences in phenomenology using the Coloured Letters and Numbers (CLaN) questionnaire which measures, amongst other attributes, the subjective automaticity/attention in synaesthetic concurrents, and their spatial localisation. Supporting our hypothesis, we found significant correlations between individual measures of synaesthetic phenomenology and BOLD responses in colour-selective areas, when contrasting inducing against non-inducing stimuli. Specifically, left-hemisphere colour area responses were stronger for synaesthetes scoring high on phenomenological localisation and automaticity/attention, while right-hemisphere colour area responses showed a relationship with localisation

  20. Ultrasound imaging of flow patterns in liver metastases from colorectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Solvig, Jan

    2004-01-01

    BACKGROUND: The ability of colour Doppler, power Doppler and echo-enhanced Doppler imaging to detect the blood flow in liver metastases from colorectal cancer was investigated. An evaluation was then made to determine whether the flow pattern could be used as an indication of disease elsewhere....... METHODS: Forty-two patients with hepatic metastases from colorectal cancer were examined, 8 of whom had local recurrence of their colorectal cancer. Seventy-seven liver metastases were evaluated with colour Doppler and power Doppler, and the presence or absence of a Doppler signal in the halo or centre...... was noted. Forty-three of these metastases were further examined after contrast media echo-enhancement. RESULTS: Signals from the peripheral halo were detected by colour Doppler imaging in 34% of the metastases, and in 77% by power Doppler (P power Doppler...

  1. Neural correlates of imagined and synaesthetic colours.

    Science.gov (United States)

    Rich, Anina N; Williams, Mark A; Puce, Aina; Syngeniotis, Ari; Howard, Matthew A; McGlone, Francis; Mattingley, Jason B

    2006-01-01

    The experience of colour is a core element of human vision. Colours provide important symbolic and contextual information not conveyed by form alone. Moreover, the experience of colour can arise without external stimulation. For many people, visual memories are rich with colour imagery. In the unusual phenomenon of grapheme-colour synaesthesia, achromatic forms such as letters, words and numbers elicit vivid experiences of colour. Few studies, however, have examined the neural correlates of such internally generated colour experiences. We used functional magnetic resonance imaging (fMRI) to compare patterns of cortical activity for the perception of external coloured stimuli and internally generated colours in a group of grapheme-colour synaesthetes and matched non-synaesthetic controls. In a voluntary colour imagery task, both synaesthetes and non-synaesthetes made colour judgements on objects presented as grey scale photographs. In a synaesthetic colour task, we presented letters that elicited synaesthetic colours, and asked participants to perform a localisation task. We assessed the neural activity underpinning these two different forms of colour experience that occur in the absence of chromatic sensory input. In both synaesthetes and non-synaesthetes, voluntary colour imagery activated the colour-selective area, V4, in the right hemisphere. In contrast, the synaesthetic colour task resulted in unique activity for synaesthetes in the left medial lingual gyrus, an area previously implicated in tasks involving colour knowledge. Our data suggest that internally generated colour experiences recruit brain regions specialised for colour perception, with striking differences between voluntary colour imagery and synaesthetically induced colours.

  2. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Ali, M.; Abid, A.R.; Rehman, T.A.; Masood, A.; Sohail, S.

    2010-01-01

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By applying 2 X 2 table sensitivity was 77.7%, specificity was 80

  3. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M; Abid, A R; Rehman, T A; Masood, A; Sohail, S [Allama Iqbal Medical College/Jinnah Hospital, Lahore(Pakistan)

    2010-10-15

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E < 10 was observed in 31 (51.7%), 11 - 15 in 20 (33.3%) and > 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By

  4. On the colour contribution to effective weak vertex in broken colour gauge theories

    International Nuclear Information System (INIS)

    Ramachandran, R.

    1979-01-01

    Treating the breaking of colour symmetry via the mixing between the colour gluons and weak bosons (a la Rajasekaran and Roy) it is observed that the colour contribution to the effective weak vertex of a quark at zero momentum transfer is zero upto 0(α). (author)

  5. COLOURFUL DIET FOR GOOD HEALTH

    OpenAIRE

    Vandana Gupta

    2017-01-01

    We are surrounded by colour and they can affect us profoundly and in ways that we may not have thought of. It is a known fact, that colours can influence your moods, feelings and emotions. Colours influence your actions and how you respond to people, situations and ideas. Apart from the colour of interiors, exteriors, our clothing and other things, the colour of food and beverage products are also extremely important. Green fruits and vegetables support eye health and may help protect against...

  6. Segmenting memory colours

    OpenAIRE

    Fredembach, Clément; Estrada, Francisco; Süsstrunk, Sabine

    2008-01-01

    Memory colours refer to the colour of specific image classes that have the essential attribute of being perceived in a consistent manner by human observers. In colour correction or rendering tasks, this consistency implies that they have to be faithfully reproduced; their importance, in that respect, is greater than other regions in an image. Before these regions can be properly addressed, one must in general detect them. There are various schemes and attributes to do so, but the preferred me...

  7. Disruptive colouration and perceptual grouping.

    Science.gov (United States)

    Espinosa, Irene; Cuthill, Innes C

    2014-01-01

    Camouflage is the primary defence of many animals and includes multiple strategies that interfere with figure-ground segmentation and object recognition. While matching background colours and textures is widespread and conceptually straightforward, less well explored are the optical 'tricks', collectively called disruptive colouration, that exploit perceptual grouping mechanisms. Adjacent high contrast colours create false edges, but this is not sufficient for an object's shape to be broken up; some colours must blend with the background. We test the novel hypothesis that this will be particularly effective when the colour patches on the animal appear to belong to, not merely different background colours, but different background objects. We used computer-based experiments where human participants had to find cryptic targets on artificial backgrounds. Creating what appeared to be bi-coloured foreground objects on bi-coloured backgrounds, we generated colour boundaries that had identical local contrast but either lay within or between (illusory) objects. As predicted, error rates for targets matching what appeared to be different background objects were higher than for targets which had otherwise identical local contrast to the background but appeared to belong to single background objects. This provides evidence for disruptive colouration interfering with higher-level feature integration in addition to previously demonstrated low-level effects involving contour detection. In addition, detection was impeded in treatments where targets were on or in close proximity to multiple background colour or tone boundaries. This is consistent with other studies which show a deleterious influence of visual 'clutter' or background complexity on search.

  8. Disruptive colouration and perceptual grouping.

    Directory of Open Access Journals (Sweden)

    Irene Espinosa

    Full Text Available Camouflage is the primary defence of many animals and includes multiple strategies that interfere with figure-ground segmentation and object recognition. While matching background colours and textures is widespread and conceptually straightforward, less well explored are the optical 'tricks', collectively called disruptive colouration, that exploit perceptual grouping mechanisms. Adjacent high contrast colours create false edges, but this is not sufficient for an object's shape to be broken up; some colours must blend with the background. We test the novel hypothesis that this will be particularly effective when the colour patches on the animal appear to belong to, not merely different background colours, but different background objects. We used computer-based experiments where human participants had to find cryptic targets on artificial backgrounds. Creating what appeared to be bi-coloured foreground objects on bi-coloured backgrounds, we generated colour boundaries that had identical local contrast but either lay within or between (illusory objects. As predicted, error rates for targets matching what appeared to be different background objects were higher than for targets which had otherwise identical local contrast to the background but appeared to belong to single background objects. This provides evidence for disruptive colouration interfering with higher-level feature integration in addition to previously demonstrated low-level effects involving contour detection. In addition, detection was impeded in treatments where targets were on or in close proximity to multiple background colour or tone boundaries. This is consistent with other studies which show a deleterious influence of visual 'clutter' or background complexity on search.

  9. Colour and Organization Studies

    DEFF Research Database (Denmark)

    Beyes, Timon

    2017-01-01

    Colour is inescapable. It fills and forms the world, shaping what can be felt and known, desired and expressed. It thus becomes social technology and organizational tool. At the same time, however, colour betrays, undermines and subverts the attempts to manage it. Based on an understanding...... of colour as aesthetic force and medium of transformation, the essay presents a montage of scenes that set up encounters with what colour does: how it affects organization, and how it is affected by organization; how it organizes what is given to perception, knowledge and organization itself, and how...

  10. Color Doppler ultrasound evaluation of asphyxial neonatal left ventricular function and its correlation with target organ damage

    Directory of Open Access Journals (Sweden)

    Cheng-Cai Chen

    2017-01-01

    Full Text Available Objective: To study the color Doppler ultrasound parameters of asphyxial neonatal left ventricular function and the correlation with target organ damage. Methods: Normal neonates, mildly asphyxial neonates and severely asphyxial neonates born in our hospital between January 2014 and December 2015 were selected as the control group (n = 46, mild asphyxia group (n = 37 and severe asphyxia group (n = 23 respectively. On the 1st day after birth, color Doppler ultrasound was used to evaluate left ventricular function, and serum was collected to determine myocardial tissue injury, brain tissue injury and brain tissue metabolism indexes. Results: Color Doppler ultrasound parameters cardiac output (CO, ejection fraction (EF and left ventricular fraction shortening (FS as well as serum folate and vitamin B12 content of mild asphyxia group and severe asphyxia group were significantly lower than those of control group (P<0.05 while serum creatine kinase isoenzyme (CK-MB, troponin I (cTnI, troponin T (cTnT, S100B, neuron-specific enolase (NSE, creatine kinase BB (CK-BB, glycogen phosphorylase BB (GPBB, and homocysteine (Hcy content were significantly higher than those of control group (P<0.05; CO, FS and EF as well as serum folate and vitamin B12 content of severe asphyxia group were significantly lower than those of mild asphyxia group (P<0.05 while serum CK-MB, cTnT, cTnI, S100B, NSE, CK-BB, GPBB and Hcy content were significantly higher than those of mild asphyxia group (P<0.05. Conclusions: Color Doppler ultrasound can accurately assess asphyxial neonatal left ventricular function damage degree and is closely related to myocardial tissue injury and brain tissue injury degree.

  11. Clinical multi-colour fluorescence imaging of malignant tumours - initial experience

    International Nuclear Information System (INIS)

    Svanberg, K.; Wang, I.; Montan, S.; Andersson-Engels, S.; Svanberg, S.; Lund Inst. of Technology

    1998-01-01

    The purpose of this study was to present a new technique for non-invasive tumour detection based on tissue fluorescence imaging. A clinically adapted multi-colour fluorescence system was employed in the real-time imaging of malignant tumours of the skin, breast, head and neck region, and urinary bladder. Tumour detection was based on the contrast displayed in fluorescence between normal and malignant tissue, related to the selective uptake of tumour-marking agents and natural chromophore differences between various tissues. In order to demarcate basal cell carcinomas of the skin, ALA was applied topically 4-6 h before the fluorescence investigation. For urinary bladder tumour visualisation, ALA was instilled into the bladder 1-2 h prior to the study. Malignant and premalignant lesions in the head and neck region were imaged after i.v. injection of HPD (Photofrin). The tumour imaging system was coupled to an endoscope. Fluorescence light emission from the tissue surface was induced with 100-ns-long optical pulses at 390 nm, generated from a frequency-doubled alexandrite laser. With the use of special image-splitting optics, the tumour fluorescence, intensified in a micro-channel plate, was imaged in 3 selected wavelength bands. These 3 images were processed together to form a new optimised-contrast image of the tumour. This image, updated at a rate of about 3 frames/s was mixed with a normal colour video image of the tissue. A clear demarcation from normal surrounding tissue was found during in vivo measurements of superficial bladder carcinoma, basal cell carcinoma of the skin, and leukoplakia with dysplasia of the lip, and in vitro investigations of resected breast cancer. (orig./MG)

  12. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  13. Colour mixing based on daylight

    International Nuclear Information System (INIS)

    Meyn, Jan-Peter

    2008-01-01

    Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large region of the colour space can be covered by mixing three primary colours derived from lossless spectral decomposition of daylight. These primaries are specified by hue, saturation and luminosity. Duality of additive and subtractive mixing is formulated quantitatively. Experimental demonstrations of calculated results are suggested. This paper is intended for undergraduate optics courses, and advanced interdisciplinary seminars on arts and physics

  14. Colour Mixing Based on Daylight

    Science.gov (United States)

    Meyn, Jan-Peter

    2008-01-01

    Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large…

  15. The differential diagnosis of thyroid solid nodules by colour doppler ultrasound%甲状腺实性结节的彩超鉴别诊断

    Institute of Scientific and Technical Information of China (English)

    于立江; 张颖; 贾齐玉; 陈海霞

    2015-01-01

    目的:探讨彩超在甲状腺结节良恶性鉴别中的应用价值。方法:应用彩超对130例手术治疗的甲状腺结节患者的结节情况进行回顾分析,并与病理结果对比,以得出恶性结节的超声表现。结果:130例(148个结节)中良性结节96个,彩超诊断100个;恶性结节52个,彩超诊断48个。彩超对甲状腺良恶性结节鉴别的灵敏性为89.66%,特异性为97.96%。结论:彩超对甲状腺结节良恶性的鉴别有重要的临床价值。%Objective To evaluate the value of the color Doppler ultrasound in differentiating benign and malignant thyroid nodule. Methods 130 cases of surgical treatment of patients with thyroid nodules were retrospective analysis by the color Doppler ultrasound,and compared with pathological results,to draw the sonographic appearances of the malignant nodules. Results Pathological results of 96 nod-ules were benign in 130 patients(148 nodules),the color Doppler ultrasound examination resule showed 100 with benign nodules;Patho-logical results of 52 nodules were malignant nodules,the color Doppler ultrasound resule for 48 nodules of malignant nodules. The sensitivi-ty,specificity of the color Doppler ultrasound in differentiating benign and malignant thyroid nodule was 89. 66%,97. 96%. Conclusion the color Doppler ultrasound is a valuable method in differentiating benign and malignant thyroid nodule.

  16. Histological Characteristics of Leg Muscles of 56-Day Old Pheasants Hatched from Eggs of Different Eggshell Colour

    Directory of Open Access Journals (Sweden)

    Dragan Zikic

    2015-05-01

    Full Text Available The aim of this paper was to examine the histological characteristics of leg muscles of pheasants hatched from eggs of a different colour. From muscle samples (M. biceps femoris of 56-day old pheasants hatched from eggs of different colour (dark brown, light brown, brown/green, blue/green histological preparations were made. Following parameters were examined: diameter of muscle cells, volume density of connective tissue in muscles, nucleo-cytoplasmatic ratio of muscle cells. Results showed that diameter of muscle cells was smaller in pheasants hatched from blue/green eggs compared to all other examinated groups. There was no differences in volume density of connective tissue in muscles between groups. Nucleo-cytoplasmatic ratio of muscle cells was higher in pheasants hatched from blue/green eggs compared to all other examinated groups. From obtained results it can be concluded that pheasants hatched from blue/green eggs had weaker muscle development than pheasants hatched from eggs of other eggshell colour. Cause of this could be related to structural differences of eggshells of various colour. This leads to weaker development of embryos and chicks hatched from blue/green eggs which reflects on differences in development of leg muscles.

  17. Colour Perception in Ancient World

    Science.gov (United States)

    Nesterov, D. I.; Fedorova, M. Yu

    2017-11-01

    How did the human thought form the surrounding color information into the persistent semantic images of a mythological, pseudoscientific and religious nature? The concepts associated with colour perception are suggested. The existence of colour environment does not depend on the human consciousness. The colour culture formation is directly related to the level of the human consciousness development and the possibility to influence the worldview and culture. The colour perception of a person goes through the stages similar to the development of colour vision in a child. Like any development, the colour consciousness has undergone stages of growth and decline, evolution and stagnation. The way of life and difficult conditions for existence made their own adjustments to the development of the human perception of the surrounding world. Wars have been both a powerful engine of progress in all spheres of life and a great destructive force demolishing the already created and preserved heritage. The surrounding world has always been interesting for humans, evoked images and fantasies in the consciousness of ancient people. Unusual and inexplicable natural phenomena spawned numerous legends and myths which was reflected in the ancient art and architecture and, accordingly, in a certain manifestation of colour in the human society. The colour perception of the ancient man, his pragmatic, utilitarian attitude to colour is considered as well as the influence of dependence on external conditions of existence and their reflection in the colour culture of antiquity. “Natural Science” conducts research in the field of the colour nature and their authorial interpretation of the Hellenic period. Several authorial concepts of the ancient world have been considered.

  18. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  19. New model for colour kinetics of plum under infrared vacuum condition and microwave drying.

    Science.gov (United States)

    Chayjan, Reza Amiri; Alaei, Behnam

    2016-01-01

    Quality of dried foods is affected by the drying method and physiochemical changes in tissue. The drying method affects properties such as colour. The colour of processed food is one of the most important quality indices and plays a determinant role in consumer acceptability of food materials and the processing method. The colour of food materials can be used as an indirect factor to determine changes in quality, since it is simpler and faster than chemical methods. The study focused on the kinetics of colour changes of plum slices, under infrared vacuum and microwave conditions. Drying the samples was implemented at the absolute pressures of 20 and 60 kPa, drying temperatures of 50 and 60°C and microwave power of 90, 270, 450 and 630 W. Colour changes were quantified by the tri-stimulus L* (whiteness/darkness), a* (redness/greenness) and b* (yellowness/blueness) model, which is an international standard for color measurement developed by the Commission Internationale d'Eclairage (CIE). These values were also used to calculate total colour change (∆E), chroma, hue angle, and browning index (BI). A new model was used for mathematical modelling of colour change kinetics. The drying process changed the colour parameters of L*, a*, and b*, causing a colour shift toward the darker region. The values of L* and hue angle decreased, whereas the values of a*, b*, ∆E, chroma and browning index increased during exposure to infrared vacuum conditions and microwave drying. Comparing the results obtained using the new model with two conventional models of zero-order and first-order kinetics indicated that the new model presented more compatibility with the data of colour kinetics for all colour parameters and drying conditions. All kinetic changes in colour parameters can be explained by the new model presented in this study. The hybrid drying system included infrared vacuum conditions and microwave power for initial slow drying of plum slices and provided the desired

  20. The twelve colourful stones

    International Nuclear Information System (INIS)

    Doria, R.M.

    1983-01-01

    A dynamics with twelve colourful stones is created based on the concepts of gauge and colour. It is associated different gauge fields to the same group. A group of gauge invariant Lagrangians is established. A gauge invariant mass term is introduced. The colourful stones physical insight is to be building blocks for quarks and leptons. (Author) [pt

  1. Supervised Object Class Colour Normalisation

    DEFF Research Database (Denmark)

    Riabchenko, Ekatarina; Lankinen, Jukka; Buch, Anders Glent

    2013-01-01

    . In this work, we develop a such colour normalisation technique, where true colours are not important per se but where examples of same classes have photometrically consistent appearance. This is achieved by supervised estimation of a class specic canonical colour space where the examples have minimal variation......Colour is an important cue in many applications of computer vision and image processing, but robust usage often requires estimation of the unknown illuminant colour. Usually, to obtain images invariant to the illumination conditions under which they were taken, color normalisation is used...... in their colours. We demonstrate the effectiveness of our method with qualitative and quantitative examples from the Caltech-101 data set and a real application of 3D pose estimation for robot grasping....

  2. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  3. Optimization of colour quality of LED lighting with reference to memory colours

    OpenAIRE

    Smet, Kevin; Ryckaert, Wouter; Pointer, Michael R.; Deconinck, Geert; Hanselaer, Peter

    2012-01-01

    Simulated and real tri- and tetrachromatic light-emitting-diode (LED) clusters were optimized for luminous efficacy of radiation (LER) and the memory colour quality metric developed by the authors. The simulated clusters showed no significant differences in achievable colour quality and LER between the different cluster types investigated. The real clusters (composed of commercially available LEDs) showed substantial differences in achievable colour quality and LER between the different clus...

  4. Colour-scent associations in a tropical orchid: three colours but two odours.

    Science.gov (United States)

    Delle-Vedove, Roxane; Juillet, Nicolas; Bessière, Jean-Marie; Grison, Claude; Barthes, Nicolas; Pailler, Thierry; Dormont, Laurent; Schatz, Bertrand

    2011-06-01

    Colour and scent are the major pollinator attractants to flowers, and their production may be linked by shared biosynthetic pathways. Species with polymorphic floral traits are particularly relevant to study the joint evolution of floral traits. We used in this study the tropical orchid Calanthe sylvatica from Réunion Island. Three distinct colour varieties are observed, presenting lilac, white or purple flowers, and named respectively C. sylvaticavar.lilacina (hereafter referred as var. lilacina), C. sylvaticavar. alba (var. alba) and C. sylvatica var. purpurea (var. purpurea). We investigated the composition of the floral scent produced by these colour varieties using the non-invasive SPME technique in the wild. Scent emissions are dominated by aromatic compounds. Nevertheless, the presence of the terpenoid (E)-4,8-dimethylnona-1,3,7-triène (DMNT) is diagnostic of var. purpurea, with the volatile organic compounds (VOC) produced by some individuals containing up to 60% of DMNT. We evidence specific colour-scent associations in C. sylvatica, with two distinct scent profiles in the three colour varieties: the lilacina-like profile containing no or very little DMNT (2%). Calanthe sylvatica var. alba individuals group with one or the other scent profile independently of their population of origin. We suggest that white-flowered individuals have evolved at least twice, once from var. lilacina and at least once from var. purpurea after the colonisation of la Réunion. White-flowered individuals may have been favoured by the particular pollinator fauna characterising the island. These flowering varieties of C. sylvatica, which display three colours but two scents profiles prove that colour is not always a good indicator of odour and that colour-scent associations may be complex, depending on pollination ecology of the populations concerned. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Ecocardiografia por Doppler tecidual no diagnóstico de rejeição após transplante cardíaco Ecocardiografía con Doppler tisular en el diagnóstico de rechazo después de transplante cardíaco Tissue doppler echocardiography in the diagnosis of heart transplantation rejection

    Directory of Open Access Journals (Sweden)

    Marcos Valério Coimbra Resende

    2011-07-01

    ,3%, especificidad de 73,8% (p = 0,001. En el análisis multivariado, la a'LAT (p = 0,001, a'SEP (p = 0,002, relación e'/a' LAT (p = 0,006, relación e'Mitral/e'LAT (p = 0,014, SINF (p = 0,009 fueron predictores de RC > 3A. Obtuvimos un escore con sensibilidad de 88,2%, precisión de 79,6%, y valor predictivo negativo de 92.9% para diagnosticar RC > 3A . El Doppler convencional (flujo mitral y pulmonar venoso no fue relevante para predecir la RC > 3A. CONCLUSIÓN: El estudio de IDT agregó información diagnóstica para predecir RC > 3A cuando fue comparado al Doppler convencional. El modelo basado en IDT puede volverse un método en potencial para detectar RC > 3A después de TC.BACKGROUND: Endomyocardial biopsy (EMB is the gold standard method for the diagnosis of cellular rejection (CR after heart transplantation (HT. OBJECTIVE: To test the hypothesis that tissue Doppler imaging (TDI could detect CR > 3A and add diagnostic information compared to conventional Doppler. METHODS: Fifty-four HT patients underwent 129 EMB and a TDI echocardiographic study within 24 hours. We compared HT patients with CR > 3A versus HT patients with CR 3A in 39/129 (30.2% EMB. The best isolated predictor for CR diagnosis was a'LAT, with a sensitivity of 76.3%, specificity of 73.8% (p = 0.001. In the multivariate analysis, a'LAT (p = 0.001, a'SEP (p = 0.002, e'/a' LAT ratio (p = 0.006, e'Mitral/ e'LAT ratio (p = 0.014, SINF (p = 0.009 predicted CR > 3A. We obtained a score with a sensitivity of 88.2%, accuracy of 79.6% and negative predictive value of 92.9% to diagnose CR > 3A. Conventional Doppler (mitral and pulmonary venous flow was not relevant to predict CR > 3A. CONCLUSION: TDI added diagnostic information to predict CR > 3A compared to conventional Doppler. A TDI-based model could become a potential method to detect CR > 3A after Heart Transplantation.

  6. Colour schemes

    DEFF Research Database (Denmark)

    van Leeuwen, Theo

    2013-01-01

    This chapter presents a framework for analysing colour schemes based on a parametric approach that includes not only hue, value and saturation, but also purity, transparency, luminosity, luminescence, lustre, modulation and differentiation.......This chapter presents a framework for analysing colour schemes based on a parametric approach that includes not only hue, value and saturation, but also purity, transparency, luminosity, luminescence, lustre, modulation and differentiation....

  7. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  8. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  9. Assessment of strain and strain rate by two-dimensional speckle tracking in mice: comparison with tissue Doppler echocardiography and conductance catheter measurements.

    Science.gov (United States)

    Ferferieva, V; Van den Bergh, A; Claus, P; Jasaityte, R; La Gerche, A; Rademakers, F; Herijgers, P; D'hooge, J

    2013-08-01

    This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 µg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.

  10. Colour isomers in quark material

    International Nuclear Information System (INIS)

    Hoegaasen, H.

    1981-01-01

    Quantum chromodynamics is stated to be analogous to quantum electrodynamics and colour to electric charge. However since there are eight gluon fields and only one photon field, and gluons have colour while photons are electrically neutral, QCD is much more complicated than QED. The concept of colour confine confinement is introduced and the addition rules for colour multiplets are discussed. It is shown that quark colour leads to isomeric meson states. Bubble chamber films from CERN groups have been examined and hyperons and (sup a)Y* resonance particles have been found, which appears to confirm the theory. (JIW)

  11. An evaluation of advanced digital colour technology for colour matching maxillofacial prosthetics.

    OpenAIRE

    Nacher-Garcia, C.

    2016-01-01

    Aim: To evaluate the reliability and reproducibility of the Spectromatch-Pro digital colour system (Spectromatch Ltd. UK) in the reproduction of simulated skin-silicone colour samples; and to determine threshold Delta E (∆E) (CIE L*a*b*) of perceptible and acceptable colour differences for maxillofacial prosthetics. Method: A two phase quantitative research design. Phase 1: tested; (i) the reproducibility of the spectrophotometer for eight subjects (n=48) scans; from four ethnic groups...

  12. Graph Colouring Algorithms

    DEFF Research Database (Denmark)

    Husfeldt, Thore

    2015-01-01

    This chapter presents an introduction to graph colouring algorithms. The focus is on vertex-colouring algorithms that work for general classes of graphs with worst-case performance guarantees in a sequential model of computation. The presentation aims to demonstrate the breadth of available...

  13. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  14. Biomimetic superwettable materials with structural colours.

    Science.gov (United States)

    Wang, Zelinlan; Guo, Zhiguang

    2017-12-05

    Structural colours and superwettability are of great interest due to their unique characteristics. However, the application of materials with either structural colours or superwettability is limited. Moreover, materials possessing both structural colours and superwettability are crucial for many practical applications. The combination of structural colours and superwettability can result in materials for use various applications, such as in sensors, detectors, bioassays, anti-counterfeiting, and liquid actuators, by controlling surfaces to repel or absorb liquids. Regarding superwettability and structural colours, surface texture and chemical composition are two factors for the construction of materials with superwettable structural colours. This review aims at offering a comprehensive elaboration of the mechanism, recent biomimetic research, and applications of biomimetic superwettable materials with structural colours. Furthermore, this review provides significant insight into the design, fabrication, and application of biomimetic superwettable materials with structural colours.

  15. Chemistry of Colours

    Indian Academy of Sciences (India)

    focus on why things have colour and what causes them to change their colour. Light is a form of .... Another pigment found in the leaves of many plants is carotene. Carotene absorbs ... structure of cyanidin changes with pH. The form shown in ...

  16. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    International Nuclear Information System (INIS)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub

    1997-01-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary β-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary β-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN

  17. Connected Colourings of Complete Graphs and Hypergraphs

    OpenAIRE

    Leader, Imre; Tan, Ta Sheng

    2014-01-01

    Gallai's colouring theorem states that if the edges of a complete graph are 3-coloured, with each colour class forming a connected (spanning) subgraph, then there is a triangle that has all 3 colours. What happens for more colours: if we $k$-colour the edges of the complete graph, with each colour class connected, how many of the $\\binom{k}{3}$ triples of colours must appear as triangles? In this note we show that the `obvious' conjecture, namely that there are always at least $\\binom{k-1}{2}...

  18. A Handheld LED Coloured-Light Mixer for Students to Learn Collaboratively the Primary Colours of Light

    Science.gov (United States)

    Nopparatjamjomras, Suchai; Chitaree, Ratchapak; Panijpan, Bhinyo

    2009-01-01

    To overcome students' inaccurate prior knowledge on primary additive colours, a coloured-light mixer has been constructed to enable students to observe directly the colours produced and reach the conclusion by themselves that the three primary colours of light are red, green, and blue (NOT red, yellow, and blue). Three closely packed tiny…

  19. The "Human Colour" Crayon: Investigating the Attitudes and Perceptions of Learners Regarding Race and Skin Colour

    Science.gov (United States)

    Alexander, Neeske; Costandius, Elmarie

    2017-01-01

    Some coloured and black learners in South Africa use a light orange or pink crayon to represent themselves in art. Many learners name this colour "human colour" or "skin colour". This is troublesome, because it could reflect exclusionary ways of representing race in images and language. This case study, conducted with two…

  20. Colourism: a global adolescent health concern.

    Science.gov (United States)

    Craddock, Nadia; Dlova, Ncoza; Diedrichs, Phillippa C

    2018-05-08

    Colourism, a form of prejudice and discrimination based solely upon skin colour, stands to jeopardize the physical health, wellbeing and life chances of adolescents of colour, globally. Research shows that adolescents can experience colourism at school and college, in the criminal justice system, at work and in the media they consume. It is therefore unsurprising that adolescents of colour often express a desire for lighter skin tones and/or are dissatisfied with their skin tone. Although research is scarce, some studies include older adolescents in their samples of skin-lightening product users. This is significant as the evidence is clear that the unmonitored use of skin-lightening products can be harmful to physical and psychological health, with evidence linking skin-lightening use to skin damage, kidney failure and depression. Although it is evident that colourism is central to the lives of adolescents of colour, more research is needed concerning the use of skin-lightening products among adolescents. Media literacy and critical race theory offer avenues in helping attenuate the harmful impact of colourism for adolescents of colour.

  1. Tissue Doppler Imaging Combined with Advanced 12-Lead ECG Analysis Might Improve Early Diagnosis of Hypertrophic Cardiomyopathy in Childhood

    Science.gov (United States)

    Femlund, E.; Schlegel, T.; Liuba, P.

    2011-01-01

    Optimization of early diagnosis of childhood hypertrophic cardiomyopathy (HCM) is essential in lowering the risk of HCM complications. Standard echocardiography (ECHO) has shown to be less sensitive in this regard. In this study, we sought to assess whether spatial QRS-T angle deviation, which has shown to predict HCM in adults with high sensitivity, and myocardial Tissue Doppler Imaging (TDI) could be additional tools in early diagnosis of HCM in childhood. Methods: Children and adolescents with familial HCM (n=10, median age 16, range 5-27 years), and without obvious hypertrophy but with heredity for HCM (n=12, median age 16, range 4-25 years, HCM or sudden death with autopsy-verified HCM in greater than or equal to 1 first-degree relative, HCM-risk) were additionally investigated with TDI and advanced 12-lead ECG analysis using Cardiax(Registered trademark) (IMED Co Ltd, Budapest, Hungary and Houston). Spatial QRS-T angle (SA) was derived from Kors regression-related transformation. Healthy age-matched controls (n=21) were also studied. All participants underwent thorough clinical examination. Results: Spatial QRS-T angle (Figure/ Panel A) and septal E/Ea ratio (Figure/Panel B) were most increased in HCM group as compared to the HCM-risk and control groups (p less than 0.05). Of note, these 2 variables showed a trend toward higher levels in HCM-risk group than in control group (p=0.05 for E/Ea and 0.06 for QRS/T by ANOVA). In a logistic regression model, increased SA and septal E/Ea ratio appeared to significantly predict both the disease (Chi-square in HCM group: 9 and 5, respectively, p less than 0.05 for both) and the risk for HCM (Chi-square in HCM-risk group: 5 and 4 respectively, p less than 0.05 for both), with further increased predictability level when these 2 variables were combined (Chi-square 10 in HCM group, and 7 in HCM-risk group, p less than 0.01 for both). Conclusions: In this small material, Tissue Doppler Imaging and spatial mean QRS-T angle

  2. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  3. Legal and Illegal Colours

    DEFF Research Database (Denmark)

    Larsen, John Christian

    2008-01-01

    opinions on food additives, including colours, and on the bioavailability and safety of nutrient sources. The WG ADD consists of several members from the AFC Panel together with selected external experts. The draft opinions go forward to the AFC Panel for discussion and final adoption. The adopted opinions......://www.efsa.europa.eu/EFSA/efsa_locale-1178620753812_1178620761956.htm. Accessed 12.05.08.] this paper only deals with some of the major issues that the Panel has faced in relation to the use of food colours. The three topics to be dealt with are (1) evaluation of illegal colours in food in the EU (EFSA, 2005), (2) re-evaluation of the authorised...... food colours in the EU (ongoing, but one opinion on Red 2G has been published; EFSA, 2007), and (3) evaluation of 'the Southampton study' on hyperactivity in children after intake of food colours (and sodium benzoate) (ongoing at the time of this presentation, but an opinion has now been published...

  4. The twelve colourful stones

    International Nuclear Information System (INIS)

    Doria, R.M.

    1984-01-01

    The gauge symmetry is extended. It is associated differents matter and gauge fields to the same group. A group of gauge invariant Lagrangians is established. A gauge invariant mass term is introduced. A massive Yang Mills is obtained. A dynamics with twelve colourful stones is created based on the concepts of gauge and colour. Structures identified as quarks and leptons are generated. A discussion about colour meaning is presented. (Author) [pt

  5. Acute Effects of Hemodialysis on Left and Right Ventricular Function: A Doppler Tissue Imaging Study

    Directory of Open Access Journals (Sweden)

    Tansel Erol

    2012-08-01

    Full Text Available Purpose: Doppler tissue imaging (DTI allows noninvasive assessment of both left ventricular (LV and right ventricular (RV function. The aim of this study was to evaluate the effect of hemodialysis (HD on LV and RV function using DTI. Method: Our study group included 30 patients on chronic HD program (mean age 45 15 years. Myocardial (Sm, Em, Am and annular velocities (Ea, Aa were measured in several cardiac territories before and after HD. Results: After HD, Ea significantly reduced from 10.8 3.4 cm/s to 9.6 2.4 cm/s (p = 0.029. Patients exhibited a lower Em following HD in all measured territories. Em/Am ratio was also reduced for each LV wall investigated after HD in all measured territories. At the RV segments, Sm, Em, and Am decreased significantly in all measured territories. Em of the anterior wall was positively related to ultrafiltration volume (r = 0.25, p = 0.006, whereas the decrease of Sm of RV basal segment correlated with a decrease of diastolic blood pressure (r = 0.23, p < 0.01. Conclusion: Our data indicate that a single HD session is associated with acute changes of systolic and diastolic parameters of LV and RV. [Cukurova Med J 2012; 37(4.000: 215-222

  6. Assessment of sustained effects of levosimendan and dobutamine on left ventricular systolic functions by using novel tissue Doppler derived indices in patients with advanced heart failure.

    Science.gov (United States)

    Oner, Ender; Erturk, Mehmet; Birant, Ali; Kurtar Mansıroglu, Aslı; Akturk, Ibrahim Faruk; Karakurt, Huseyin; Yalcin, Ahmet Arif; Uzun, Fatih; Somuncu, Mustafa Umut; Yildirim, Aydin

    2015-01-01

    Previous studies comparing levosimendan vs. dobutamine have revealed that levosimendan is better in relieving symptoms. Echocardiographic studies have been done using second measurements immediately following a dobutamine infusion or while it was still being administered. The aim of our study was assessment of sustained effects of 24 h levosimendan and dobutamine infusions on left ventricular systolic functions. A total of 61 patients with acutely decompensated heart failure with New York Heart Association (NYHA) class III or IV symptoms were randomized to receive either levosimendan or dobutamine 2:1 in an open label fashion. Before and 5 days after the initiation of infusions, functional class was assessed, N-terminal prohormone of B-type natriuretic peptide (NT-proBNP) levels and left ventricular ejection fraction (LVEF), mitral inflow peak E and A wave velocity, and E/A ratios were measured; using tissue Doppler imaging, isovolumic myocardial acceleration (IVA), peak myocardial velocity during isovolumic contraction (IVV), peak systolic velocity during ejection period (Sa), early (E') and late (A') diastolic velocities, and E'/A' and E/E' ratios were measured. The NYHA class improved in both groups, but improvements were prominent in the levosimendan group. NT-proBNP levels were significantly reduced in the levosimendan group. Improvements in LVEF and diastolic indices were significant in the levosimendan group. Tissue Doppler-derived systolic indices of IVV and IVA increased significantly in the levosimendan group. Improvements in left ventricular systolic and diastolic functions continue after a levosimendan infusion.

  7. Consumer exposures to anthocyanins from colour additives, colouring foodstuffs and from natural occurrence in foods.

    Science.gov (United States)

    Tennant, David R; Klingenberg, Andreas

    2016-06-01

    Anthocyanins are responsible for the red/blue colour of grapes, currants, and other fruits and vegetables. They may also be extracted for use as colour additives (E163) or concentrated for use as colouring foods. Consumer exposures have been assessed using data on natural occurrence, use levels and frequencies from food manufacturers and European food consumption data. Intakes from natural occurrence can be up to 4 mg kg bw(-1) day(-1) at the mean and up to 17 mg kg bw(-1) day(-1) for children who are high level consumers of red/black berries and small fruits. High-level intakes for children from food colour and colouring food applications lie in the range 0.3-6.3 mg kg bw(-1) day(-1) and for adults at 0.6-2.8 mg kg bw(-1) day(-1). Exposures from food colour use and colouring foods separately or combined are therefore lower than those from natural occurrence in foods.

  8. The original colours of fossil beetles.

    Science.gov (United States)

    McNamara, Maria E; Briggs, Derek E G; Orr, Patrick J; Noh, Heeso; Cao, Hui

    2012-03-22

    Structural colours, the most intense, reflective and pure colours in nature, are generated when light is scattered by complex nanostructures. Metallic structural colours are widespread among modern insects and can be preserved in their fossil counterparts, but it is unclear whether the colours have been altered during fossilization, and whether the absence of colours is always real. To resolve these issues, we investigated fossil beetles from five Cenozoic biotas. Metallic colours in these specimens are generated by an epicuticular multi-layer reflector; the fidelity of its preservation correlates with that of other key cuticular ultrastructures. Where these other ultrastructures are well preserved in non-metallic fossil specimens, we can infer that the original cuticle lacked a multi-layer reflector; its absence in the fossil is not a preservational artefact. Reconstructions of the original colours of the fossils based on the structure of the multi-layer reflector show that the preserved colours are offset systematically to longer wavelengths; this probably reflects alteration of the refractive index of the epicuticle during fossilization. These findings will allow the former presence, and original hue, of metallic structural colours to be identified in diverse fossil insects, thus providing critical evidence of the evolution of structural colour in this group.

  9. Hormonal regulation of colour change in eyes of a cryptic fish

    Directory of Open Access Journals (Sweden)

    Helen Nilsson Sköld

    2015-01-01

    Full Text Available Colour change of the skin in lower vertebrates such as fish has been a subject of great scientific and public interest. However, colour change also takes place in eyes of fish and while an increasing amount of data indicates its importance in behaviour, very little is known about its regulation. Here, we report that both eye and skin coloration change in response to white to black background adaptation in live sand goby Pomatoschistus minutes, a bentic marine fish. Through in vitro experiments, we show that noradrenaline and melanocyte concentrating hormone (MCH treatments cause aggregation of pigment organelles in the eye chromatophores. Daylight had no aggregating effect. Combining forskolin to elevate intracellular cyclic adenosine monophosphate (cAMP with MCH resulted in complete pigment dispersal and darkening of the eyes, whereas combining prolactin, adrenocorticotrophic hormone (ACTH or melanocyte stimulating hormone (α-MSH with MCH resulted in more yellow and red eyes. ACTH and MSH also induced dispersal in the melanophores, resulting in overall darker eyes. By comparing analysis of eyes, skin and peritoneum, we conclude that the regulation pattern is similar between these different tissues in this species which is relevant for the cryptic life strategy of this species. With the exception of ACTH which resulted in most prominent melanophore pigment dispersal in the eyes, all other treatments provided similar results between tissue types. To our knowledge, this is the first study that has directly analysed hormonal regulation of physiological colour change in eyes of fish.

  10. Computed estimates of maximum temperature elevations in fetal tissues during transabdominal pulsed Doppler examinations.

    Science.gov (United States)

    Bly, S H; Vlahovich, S; Mabee, P R; Hussey, R G

    1992-01-01

    Measured characteristics of ultrasonic fields were obtained in submissions from manufacturers of diagnostic ultrasound equipment for devices operating in pulsed Doppler mode. Simple formulae were used with these data to generate upper limits to fetal temperature elevations, delta Tlim, during a transabdominal pulsed Doppler examination. A total of 236 items were analyzed, each item being a console/transducer/operating-mode/intended-use combination, for which the spatial-peak temporal-average intensity, ISPTA, was greater than 500 mW cm-2. The largest calculated delta Tlim values were approximately 1.5, 7.1 and 8.7 degrees C for first-, second- and third-trimester examinations, respectively. The vast majority of items yielded delta Tlim values which were less than 1 degree C in the first trimester. For second- and third-trimester examinations, where heating of fetal bone determines delta Tlim, most delta Tlim values were less than 4 degrees C. The clinical significance of the results is discussed.

  11. Fast Doppler as a novel bedside measure of cerebral perfusion in preterm infants.

    Science.gov (United States)

    Peeples, Eric S; Mehic, Edin; Mourad, Pierre D; Juul, Sandra E

    2016-02-01

    Altered cerebral perfusion from impaired autoregulation may contribute to the morbidity and mortality associated with premature birth. We hypothesized that fast Doppler imaging could provide a reproducible bedside estimation of cerebral perfusion and autoregulation in preterm infants. This is a prospective pilot study using fast Doppler ultrasound to assess blood flow velocity in the basal ganglia of 19 subjects born at 26-32 wk gestation. Intraclass correlation provided a measure of test-retest reliability, and linear regression of cerebral blood flow velocity and heart rate or blood pressure allowed for estimations of autoregulatory ability. The intraclass correlation when imaging in the first 48 h of life was 0.634. We found significant and independent correlations between the systolic blood flow velocity and both systolic blood pressure and heart rate (P = 0.015 and 0.012 respectively) only in the 26-28 wk gestational age infants in the first 48 h of life. Our results suggest that fast Doppler provides reliable bedside measurements of cerebral blood flow velocity at the tissue level in premature infants, acting as a proxy for cerebral tissue perfusion. Additionally, autoregulation appears to be impaired in the extremely preterm infants, even within a normal range of blood pressures.

  12. On colour categorization of nature

    NARCIS (Netherlands)

    Yendrikhovskij, S.N.

    1998-01-01

    The following research elaborates on some of the 'semantic' and 'algorithmic' aspects of the categorization process for thc colour domain. The structure of colour categories is argued to resemble the structure of Ihe distribution of colours in the perceived world. This distribution can be

  13. Discrepancies between descriptions and illustrations of colours in Congo red-stained amyloid, and explanation of discrepant colours.

    Science.gov (United States)

    Howie, Alexander J; Owen-Casey, Mared P

    2010-09-01

    Congo red-stained sections of amyloid may show various colours between crossed polariser and analyser. The aims were to see how papers described the colours, to compare descriptions with illustrations, and to explain the colours. In 160 papers on Congo red-stained amyloid, the commonest descriptions were 'green birefringence' and 'apple-green birefringence'. In 191 figures in 82 papers, 59 (31%) showed a pure green colour, 62 (32%) showed green and yellow or blue and yellow, 38 (20%) showed green and a colour other than yellow, mostly red, and 32 (17%) showed other colours. Discrepancies between colours reported and illustrated were noted in 127 figures (66%). Most (77) were between green alone in descriptions and green and another colour in figures, and 30 were between green in descriptions and no green at all in figures. Pure green can be seen in ideal conditions, but more often there are green and yellow, explained by strain birefringence, and green and red or other combinations, explained by uncrossing of polariser and analyser. These other anomalous colours are just as characteristic of amyloid as the pure green colour. Many papers on Congo red-stained amyloid appear to describe what is expected theoretically rather than what is actually seen.

  14. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  15. What do colour-blind people really see?

    NARCIS (Netherlands)

    Hogervorst, M.A.; Alferdinck, J.W.A.M.

    2008-01-01

    Problem: colour perception of dichromats (colour-blind persons) Background: Various models have been proposed (e. g. Walraven & Alferdinck, 1997; Brettel et al. , 1997) to model reduced colour vision of colour-blind people. It is clear that colour-blind people cannot distinguish certain object

  16. Influence of colour in working environment

    OpenAIRE

    Gabrovšek, Barbara

    2014-01-01

    Anton Trstenjak wrote: »Our life is practically sinking in the sea of light and colours.« Different colours create different psycho-physiological responses. That is why colours have various impacts on human experiences and arrangements of our attention. When we know how control the colours in our environment, we can influence human psychological and physiological well-being and attention in the space. In my thesis, I explore how colours affect our feelings, our body and attention. Knowing all...

  17. Electrophysiological evidence for colour effects on the naming of colour diagnostic and noncolour diagnostic objects

    OpenAIRE

    Bramão, I.; Francisco, A.; Inácio , F.; Faísca, L.; Reis, A.; Petersson, K.

    2012-01-01

    In this study, we investigated the level of visual processing at which surface colour information improves the naming of colour diagnostic and noncolour diagnostic objects. Continuous electroencephalograms were recorded while participants performed a visual object naming task in which coloured and black-and-white versions of both types of objects were presented. The black-and-white and the colour presentations were compared in two groups of event-related potentials (ERPs): (1) The P1 and N1 c...

  18. Colour correct: the interactive effects of food label nutrition colouring schemes and food category healthiness on health perceptions.

    Science.gov (United States)

    Nyilasy, Gergely; Lei, Jing; Nagpal, Anish; Tan, Joseph

    2016-08-01

    The purpose of the present study was to examine the effects of food label nutrition colouring schemes in interaction with food category healthiness on consumers' perceptions of food healthiness. Three streams of colour theory (colour attention, colour association and colour approach-avoidance) in interaction with heuristic processing theory provide consonant predictions and explanations for the underlying psychological processes. A 2 (food category healthiness: healthy v. unhealthy)×3 (food label nutrient colouring schemes: healthy=green, unhealthy=red (HGUR) v. healthy=red, unhealthy=green (HRUG) v. no colour (control)) between-subjects design was used. The research setting was a randomised-controlled experiment using varying formats of food packages and nutritional information colouring. Respondents (n 196) sourced from a national consumer panel, USA. The findings suggest that, for healthy foods, the nutritional colouring schemes reduced perceived healthiness, irrespective of which nutrients were coloured red or green (healthinesscontrol=4·86; healthinessHGUR=4·10; healthinessHRUG=3·70). In contrast, for unhealthy foods, there was no significant difference in perceptions of food healthiness when comparing different colouring schemes against the control. The results make an important qualification to the common belief that colour coding can enhance the correct interpretation of nutrition information and suggest that this incentive may not necessarily support healthier food choices in all situations.

  19. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  20. Colour is more than hue: preferences for compiled colour traits in the stingless bees Melipona mondury and M. quadrifasciata.

    Science.gov (United States)

    Koethe, Sebastian; Bossems, Jessica; Dyer, Adrian G; Lunau, Klaus

    2016-10-01

    The colour vision of bees has been extensively analysed in honeybees and bumblebees, but few studies consider the visual perception of stingless bees (Meliponini). In a five-stage experiment the preference for colour intensity and purity, and the preference for the dominant wavelength were tested by presenting four colour stimuli in each test to freely flying experienced workers of two stingless bee species, Melipona mondury and Melipona quadrifasciata. The results with bee-blue, bee-UV-blue and bee-green colours offered in four combinations of varying colour intensity and purity suggest a complex interaction between these colour traits for the determination of colour choice. Specifically, M. mondury preferred bee-UV-blue colours over bee-green, bee-blue and bee-blue-green colours while M. quadrifasciata preferred bee-green colour stimuli. Moreover in M. mondury the preferences were different if the background colour was changed from grey to green. There was a significant difference between species where M. mondury preferred UV-reflecting over UV-absorbing bee-blue-green colour stimuli, whereas M. quadrifasciata showed an opposite preference. The different colour preferences of the free flying bees in identical conditions may be caused by the bees' experience with natural flowers precedent to the choice tests, suggesting reward partitioning between species.

  1. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  2. The control of attentional target selection in a colour/colour conjunction task.

    Science.gov (United States)

    Berggren, Nick; Eimer, Martin

    2016-11-01

    To investigate the time course of attentional object selection processes in visual search tasks where targets are defined by a combination of features from the same dimension, we measured the N2pc component as an electrophysiological marker of attentional object selection during colour/colour conjunction search. In Experiment 1, participants searched for targets defined by a combination of two colours, while ignoring distractor objects that matched only one of these colours. Reliable N2pc components were triggered by targets and also by partially matching distractors, even when these distractors were accompanied by a target in the same display. The target N2pc was initially equal in size to the sum of the two N2pc components to the two different types of partially matching distractors and became superadditive from approximately 250 ms after search display onset. Experiment 2 demonstrated that the superadditivity of the target N2pc was not due to a selective disengagement of attention from task-irrelevant partially matching distractors. These results indicate that attention was initially deployed separately and in parallel to all target-matching colours, before attentional allocation processes became sensitive to the presence of both matching colours within the same object. They suggest that attention can be controlled simultaneously and independently by multiple features from the same dimension and that feature-guided attentional selection processes operate in parallel for different target-matching objects in the visual field.

  3. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  4. Characterising the variations in ethnic skin colours: a new calibrated data base for human skin.

    Science.gov (United States)

    Xiao, K; Yates, J M; Zardawi, F; Sueeprasan, S; Liao, N; Gill, L; Li, C; Wuerger, S

    2017-02-01

    Accurate skin colour measurements are important for numerous medical applications including the diagnosis and treatment of cutaneous disorders and the provision of maxillofacial soft tissue prostheses. In this study, we obtained accurate skin colour measurements from four different ethnic groups (Caucasian, Chinese, Kurdish, Thai) and at four different body locations (Forehead, cheek, inner arm, back of hand) with a view of establishing a new skin colour database for medical and cosmetic applications. Skin colours are measured using a spectrophotometer and converted to a device-independent standard colour appearance space (CIELAB) where skin colour is expressed as values along the three dimensions: Lightness L*, Redness a* and Yellowness b*. Skin colour differences and variation are then evaluated as a function of ethnicity and body location. We report three main results: (1) When plotted in a standard colour appearance space (CIELAB), skin colour distributions for the four ethnic groups overlap significantly, although there are systematic mean differences. Between ethnicities, the most significant skin colour differences occur along the yellowness dimension, with Thai skin exhibiting the highest yellowness (b*) value and Caucasian skin the lowest value. Facial redness (a*) is invariant across the four ethnic groups. (2) Between different body locations, there are significant variations in redness (a*), with the forehead showing the highest redness value and the inner arm the lowest. (3) The colour gamut is smallest in the Chinese sample and largest in the Caucasian sample, with the Chinese gamut lying entirely the Caucasian gamut. Similarly, the largest variability in skin tones is found in the Caucasian group, and the smallest in the Chinese group. Broadly speaking, skin colour variation can be explained by two main factors: individual differences in lightness and yellowness are mostly due to ethnicity, whereas differences in redness are primarily due to

  5. Colour-rendition properties of solid-state lamps

    Energy Technology Data Exchange (ETDEWEB)

    Zukauskas, A [Institute of Applied Research, Vilnius University, Sauletekio al. 9, bldg. III, Vilnius, LT-10222 (Lithuania); Vaicekauskas, R [Department of Computer Science, Vilnius University, Naugarduko g. 24, Vilnius, LT-03225 (Lithuania); Shur, M S, E-mail: arturas.zukauskas@ff.vu.l [Department of Electrical, Computer, and System Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY 12180 (United States)

    2010-09-08

    The applicability of colour-quality metrics to solid-state light sources is validated and the results of the assessment of colour-rendition characteristics of various lamps are presented. The standard colour-rendering index metric or a refined colour-quality scale metric fails to distinguish between two principle colour-rendition properties of illumination: the ability to render object colours with high fidelity and the ability to increase chromatic contrast, especially when the spectra of light sources contain a few narrow-band electroluminescence components. Supplementing these metrics by the known figures of merit that measure the gamut area of a small number of test colour samples does not completely resolve this issue. In contrast, the statistical approach, which is based on sorting a very large number of test colour samples in respect of just-perceivable colour distortions of several kinds, offers a comprehensive assessment of colour-rendition properties of solid-state light sources. In particular, two statistical indices, colour-fidelity index (CFI) and colour-saturation index (CSI), which are the relative numbers of object colours rendered with high fidelity and increased saturation, respectively, are sufficient to reveal and assess three distinct types of solid-state light sources. These are (i) high-fidelity lamps, which cover the entire spectrum with the spectral components present in the wavelength ranges of both 530-610 nm and beyond 610 nm (e.g. trichromatic warm white phosphor-converted (pc) light-emitting diodes (LEDs), red-amber-green-blue LED clusters, complementary clusters of white and coloured LEDs); (ii) colour-saturating lamps, which lack power in the 530-610 nm wavelength range (e.g. red-green-blue or red-cyan-blue LED clusters) and (iii) colour-dulling lamps, which lack power for wavelengths longer than 610 nm (dichromatic daylight pc LEDs and amber-green-blue LED clusters). Owing to a single statistical format, CSI and CFI can be used for

  6. Colour-rendition properties of solid-state lamps

    International Nuclear Information System (INIS)

    Zukauskas, A; Vaicekauskas, R; Shur, M S

    2010-01-01

    The applicability of colour-quality metrics to solid-state light sources is validated and the results of the assessment of colour-rendition characteristics of various lamps are presented. The standard colour-rendering index metric or a refined colour-quality scale metric fails to distinguish between two principle colour-rendition properties of illumination: the ability to render object colours with high fidelity and the ability to increase chromatic contrast, especially when the spectra of light sources contain a few narrow-band electroluminescence components. Supplementing these metrics by the known figures of merit that measure the gamut area of a small number of test colour samples does not completely resolve this issue. In contrast, the statistical approach, which is based on sorting a very large number of test colour samples in respect of just-perceivable colour distortions of several kinds, offers a comprehensive assessment of colour-rendition properties of solid-state light sources. In particular, two statistical indices, colour-fidelity index (CFI) and colour-saturation index (CSI), which are the relative numbers of object colours rendered with high fidelity and increased saturation, respectively, are sufficient to reveal and assess three distinct types of solid-state light sources. These are (i) high-fidelity lamps, which cover the entire spectrum with the spectral components present in the wavelength ranges of both 530-610 nm and beyond 610 nm (e.g. trichromatic warm white phosphor-converted (pc) light-emitting diodes (LEDs), red-amber-green-blue LED clusters, complementary clusters of white and coloured LEDs); (ii) colour-saturating lamps, which lack power in the 530-610 nm wavelength range (e.g. red-green-blue or red-cyan-blue LED clusters) and (iii) colour-dulling lamps, which lack power for wavelengths longer than 610 nm (dichromatic daylight pc LEDs and amber-green-blue LED clusters). Owing to a single statistical format, CSI and CFI can be used for

  7. Colorimetry and prime colours--a theorem.

    Science.gov (United States)

    Hornaes, Hans Petter; Wold, Jan Henrik; Farup, Ivar

    2005-08-01

    Human colour vision is the result of a complex process involving topics ranging from physics of light to perception. Whereas the diversity of light entering the eye in principle span an infinite-dimensional vector space in terms of the spectral power distributions, the space of human colour perceptions is three dimensional. One important consequence of this is that a variety of colours can be visually matched by a mixture of only three adequately chosen reference lights. It has been observed that there exists one particular set of monochromatic reference lights that, according to a certain definition, is optimal for producing colour matches. These reference lights are commonly denoted prime colours. In the present paper, we intend to rigorously show that the existence of prime colours is not particular to the human visual system as sometimes stated, but rather an algebraic consequence of the manner in which a kind of colorimetric functions called colour-matching functions are defined and transformed. The solution is based on maximisation of a determinant determining the gamut size of the colour space spanned by the prime colours. Cramer's rule for solving a set of linear equations is an essential part of the proof. By means of examples, it is shown that mathematically the optimal set of reference lights is not unique in general, and that the existence of a maximum determinant is not a necessary condition for the existence of prime colours.

  8. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  9. The unsuitability of HTML-based colour charts for estimating animal colours--a comment on Berggren and Merilä (2004).

    Science.gov (United States)

    Stevens, Martin; Cuthill, Innes C

    2005-08-30

    A variety of techniques are used to study the colours of animal signals, including the use of visual matching to colour charts. This paper aims to highlight why they are generally an unsatisfactory tool for the measurement and classification of animal colours and why colour codes based on HTML (really RGB) standards, as advocated in a recent paper, are particularly inappropriate. There are many theoretical arguments against the use of colour charts, not least that human colour vision differs markedly from that of most other animals. However, the focus of this paper is the concern that, even when applied to humans, there is no simple 1:1 mapping from an RGB colour space to the perceived colours in a chart (the results are both printer- and illumination-dependent). We support our criticisms with data from colour matching experiments with humans, involving self-made, printed colour charts. Colour matching experiments with printed charts involving 11 subjects showed that the choices made by individuals were significantly different between charts that had exactly the same RGB values, but were produced from different printers. Furthermore, individual matches tended to vary under different lighting conditions. Spectrophotometry of the colour charts showed that the reflectance spectra of the charts varied greatly between printers and that equal steps in RGB space were often far from equal in terms of reflectance on the printed charts. In addition to outlining theoretical criticisms of the use of colour charts, our empirical results show that: individuals vary in their perception of colours, that different printers produce strikingly different results when reproducing what should be the same chart, and that the characteristics of the light irradiating the surface do affect colour perception. Therefore, we urge great caution in the use of colour charts to study animal colour signals. They should be used only as a last resort and in full knowledge of their limitations, with

  10. Colour revolutions: criminal-legal aspect

    Directory of Open Access Journals (Sweden)

    Sergey Alekseyevich Gordeychik

    2015-03-01

    Full Text Available Objective basing on the analysis of colour revolution technologies in different countries to formulate propositions for improving criminal legislation aimed at counteraction against this phenomenon. Methods general scientific induction deduction analysis synthesis and specific scientific formaljuridical and comparativelegal. Results using the results of colour revolutionsrsquo research carried out by political scientists the author evaluates the character and level of public danger of colour revolutions. The author states that the colour revolutions threaten the normal existence of the country or several countries. The conclusion is made that the colour revolutions must be counteracted by criminallegal means. The article states the absence of norms in the existing criminal legislation which would impose criminal liability on organizers incendiaries and participants of colour revolutions. It is proposed to supplement the existing criminal law with the norm stipulating the liability for such deeds and to insert this norm into Art. 34 ldquoCrimes against peace and security of humanityrdquo thus equating organization preparation and implementing colour revolutions with planning preparation launching and conducting an aggressive war Art. 353 of the Russian Criminal Code. Scientific novelty basing on the existing legal norms modern politological and juridical scientific literature a conclusion is made that the colour revolutions are based on the abuse of law. This allows the organizers of colour revolutions to legally prepare and implement the subversion of undesirable political regimes. The author formulates proposals for supplementing the criminal legislation. Practical value the materials and conclusions of the article can be used in lawmaking activity when elaborating the drafts of legal acts for changing and supplementing the Russian Criminal Code for research activity when preparing monographs and dissertations tutorials and articles when

  11. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  12. Colour Day: an innovative project

    CERN Multimedia

    Staff Association

    2016-01-01

    This year, the Children’s Day-Care Centre (EVE) and School works on the theme of colours. Every class has their own project revolving around this common theme. The class of Claire, Sandrine and Nadia, introduced a monthly “Colour Day”. The objective of this day is to offer children different activities (arts and crafts, baking, etc.) designed around a specific colour. The children get a chance to decorate their classroom and learn in many different ways inspired by the colours blue, red, and many others. The parents are also called to contribute and invited to dress their children in the colour of the day. In September, we discovered the colour blue, in October it was time for red, and in mid-November yellow will brighten up our structure. Everyone plays along, making this a very festive day for us all. On Tuesday, 20 September, we saw the whole School turn blue! We were all dressed in blue and we made blue paintings, too! We made beautiful artwork inspired by artists like Ma...

  13. Assessment of regional systolic and diastolic myocardial function using tissue Doppler and strain imaging in dogs with dilated cardiomyopathy.

    Science.gov (United States)

    Chetboul, Valérie; Gouni, Vassiliki; Sampedrano, Carolina Carlos; Tissier, Renaud; Serres, François; Pouchelon, Jean-Louis

    2007-01-01

    Tissue Doppler Imaging (TDI) or strain (St) imaging could provide sensitive indices for early detection and treatment follow-up of canine dilated cardiomyopathy (DCM). Analysis of TDI and St features in dogs with overt DCM is a prerequisite before using these new criteria in prospective screenings of predisposed families or in clinical trials. Radial and longitudinal right and left myocardial motion, assessed by TDI and St variables, is altered in dogs with DCM. Case records for 26 dogs; 14 with DCM and 12 healthy controls of comparable age and weight were reviewed. A retrospective analysis was conducted of conventional echocardiography, 2-dimensional color TDI, and St imaging data. The DCM group was characterized by decreases in radial and longitudinal systolic velocity gradients of the left ventricular free wall (LVFW), radial and longitudinal absolute values of peak systolic St of the LVFW, and longitudinal systolic right ventricular (RV) velocities (all P canine DCM.

  14. Block colourings of 6-cycle systems

    Directory of Open Access Journals (Sweden)

    Paola Bonacini

    2017-01-01

    Full Text Available Let \\(\\Sigma=(X,\\mathcal{B}\\ be a \\(6\\-cycle system of order \\(v\\, so \\(v\\equiv 1,9\\mod 12\\. A \\(c\\-colouring of type \\(s\\ is a map \\(\\phi\\colon\\mathcal {B}\\rightarrow \\mathcal{C}\\, with \\(C\\ set of colours, such that exactly \\(c\\ colours are used and for every vertex \\(x\\ all the blocks containing \\(x\\ are coloured exactly with \\(s\\ colours. Let \\(\\frac{v-1}{2}=qs+r\\, with \\(q, r\\geq 0\\. \\(\\phi\\ is equitable if for every vertex \\(x\\ the set of the \\(\\frac{v-1}{2}\\ blocks containing \\(x\\ is partitioned in \\(r\\ colour classes of cardinality \\(q+1\\ and \\(s-r\\ colour classes of cardinality \\(q\\. In this paper we study bicolourings and tricolourings, for which, respectively, \\(s=2\\ and \\(s=3\\, distinguishing the cases \\(v=12k+1\\ and \\(v=12k+9\\. In particular, we settle completely the case of \\(s=2\\, while for \\(s=3\\ we determine upper and lower bounds for \\(c\\.

  15. Colour dependence of zodiacal light models

    Science.gov (United States)

    Giese, R. H.; Hanner, M. S.; Leinert, C.

    1973-01-01

    Colour models of the zodiacal light in the ecliptic have been calculated for both dielectric and metallic particles in the sub-micron and micron size range. Two colour ratios were computed, a blue ratio and a red ratio. The models with a size distribution proportional to s to the -2.5 power ds (where s is the particle radius) generally show a colour close to the solar colour and almost independent of elongation. Especially in the blue colour ratio there is generally no significant dependence on the lower cutoff size (0.1-1 micron). The main feature of absorbing particles is a reddening at small elongations. The models for size distributions proportional to s to the -4 power ds show larger departures from solar colour and more variation with model parameters. Colour measurements, including red and near infra-red, therefore are useful to distinguish between flat and steep size spectra and to verify the presence of slightly absorbing particles.

  16. Skin Colour Analysis of Iraqi Kurdish Population

    OpenAIRE

    Zardawi, Faraedon M; Xiao, Kaida; Yates, Julian M

    2015-01-01

    Objective: Skin colour measurement and analysis was performed for Iraqi Kurdish population in sulaimani city. The purpose of this study was to produce a dedicated skin shade guide for precise colour reproduction and colour matching of maxillofacial prostheses with the patient’s original skin colour. Methodology: A skin colour measurement was undertaken for 140 subjects (73 female and 67 male). A method of capturing their (L* a* b*) colour values from nine body parts was performed using a Mi...

  17. Plasmonic colour laser printing

    DEFF Research Database (Denmark)

    Zhu, Xiaolong; Vannahme, Christoph; Højlund-Nielsen, Emil

    2016-01-01

    -beam lithography (EBL) or focused ion beam (FIB), both expensive and not scalable processes that are not suitable for post-processing customization. Here we show a method of colour printing on nanoimprinted plasmonic metasurfaces using laser post-writing. Laser pulses induce transient local heat generation...... that leads to melting and reshaping of the imprinted nanostructures. Depending on the laser pulse energy density, different surface morphologies that support different plasmonic resonances leading to different colour appearances can be created. Using this technique we can print all primary colours...

  18. Assessing the colour quality of LED sources

    DEFF Research Database (Denmark)

    Jost-Boissard, S.; Avouac, P.; Fontoynont, Marc

    2015-01-01

    The CIE General Colour Rendering Index is currently the criterion used to describe and measure the colour-rendering properties of light sources. But over the past years, there has been increasing evidence of its limitations particularly its ability to predict the perceived colour quality of light...... sources and especially some LEDs. In this paper, several aspects of perceived colour quality are investigated using a side-by-side paired comparison method, and the following criteria: naturalness of fruits and vegetables, colourfulness of the Macbeth Color Checker chart, visual appreciation...... (attractiveness/ preference) and colour difference estimations for both visual scenes. Forty-five observers with normal colour vision evaluated nine light sources at 3000 K, and 36 observers evaluated eight light sources at 4000 K. Our results indicate that perceived colour differences are better dealt...

  19. Synaesthetic colour in the brain: beyond colour areas. A functional magnetic resonance imaging study of synaesthetes and matched controls.

    Science.gov (United States)

    van Leeuwen, Tessa M; Petersson, Karl Magnus; Hagoort, Peter

    2010-08-10

    In synaesthesia, sensations in a particular modality cause additional experiences in a second, unstimulated modality (e.g., letters elicit colour). Understanding how synaesthesia is mediated in the brain can help to understand normal processes of perceptual awareness and multisensory integration. In several neuroimaging studies, enhanced brain activity for grapheme-colour synaesthesia has been found in ventral-occipital areas that are also involved in real colour processing. Our question was whether the neural correlates of synaesthetically induced colour and real colour experience are truly shared. First, in a free viewing functional magnetic resonance imaging (fMRI) experiment, we located main effects of synaesthesia in left superior parietal lobule and in colour related areas. In the left superior parietal lobe, individual differences between synaesthetes (projector-associator distinction) also influenced brain activity, confirming the importance of the left superior parietal lobe for synaesthesia. Next, we applied a repetition suppression paradigm in fMRI, in which a decrease in the BOLD (blood-oxygenated-level-dependent) response is generally observed for repeated stimuli. We hypothesized that synaesthetically induced colours would lead to a reduction in BOLD response for subsequently presented real colours, if the neural correlates were overlapping. We did find BOLD suppression effects induced by synaesthesia, but not within the colour areas. Because synaesthetically induced colours were not able to suppress BOLD effects for real colour, we conclude that the neural correlates of synaesthetic colour experience and real colour experience are not fully shared. We propose that synaesthetic colour experiences are mediated by higher-order visual pathways that lie beyond the scope of classical, ventral-occipital visual areas. Feedback from these areas, in which the left parietal cortex is likely to play an important role, may induce V4 activation and the percept of

  20. Synaesthetic colour in the brain: beyond colour areas. A functional magnetic resonance imaging study of synaesthetes and matched controls.

    Directory of Open Access Journals (Sweden)

    Tessa M van Leeuwen

    Full Text Available BACKGROUND: In synaesthesia, sensations in a particular modality cause additional experiences in a second, unstimulated modality (e.g., letters elicit colour. Understanding how synaesthesia is mediated in the brain can help to understand normal processes of perceptual awareness and multisensory integration. In several neuroimaging studies, enhanced brain activity for grapheme-colour synaesthesia has been found in ventral-occipital areas that are also involved in real colour processing. Our question was whether the neural correlates of synaesthetically induced colour and real colour experience are truly shared. METHODOLOGY/PRINCIPAL FINDINGS: First, in a free viewing functional magnetic resonance imaging (fMRI experiment, we located main effects of synaesthesia in left superior parietal lobule and in colour related areas. In the left superior parietal lobe, individual differences between synaesthetes (projector-associator distinction also influenced brain activity, confirming the importance of the left superior parietal lobe for synaesthesia. Next, we applied a repetition suppression paradigm in fMRI, in which a decrease in the BOLD (blood-oxygenated-level-dependent response is generally observed for repeated stimuli. We hypothesized that synaesthetically induced colours would lead to a reduction in BOLD response for subsequently presented real colours, if the neural correlates were overlapping. We did find BOLD suppression effects induced by synaesthesia, but not within the colour areas. CONCLUSIONS/SIGNIFICANCE: Because synaesthetically induced colours were not able to suppress BOLD effects for real colour, we conclude that the neural correlates of synaesthetic colour experience and real colour experience are not fully shared. We propose that synaesthetic colour experiences are mediated by higher-order visual pathways that lie beyond the scope of classical, ventral-occipital visual areas. Feedback from these areas, in which the left parietal

  1. Colour preferences in nest-building zebra finches.

    Science.gov (United States)

    Muth, Felicity; Steele, Matthew; Healy, Susan D

    2013-10-01

    Some bird species are selective in the materials they choose for nest building, preferring, for example, materials of one colour to others. However, in many cases the cause of these preferences is not clear. One of those species is the zebra finch, which exhibits strong preferences for particular colours of nest material. In an attempt to determine why these birds strongly prefer one colour of material over another, we compared the preferences of paired male zebra finches for nest material colour with their preferences for food of the same colours. We found that birds did indeed prefer particular colours of nest material (in most cases blue) but that they did not generally prefer food of one colour over the other colours. It appears, then, that a preference for one colour or another of nest material is specific to the nest-building context. This article is part of a Special Issue entitled: insert SI title. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  3. Bio deterioration behaviour in different colour roofing tiles (red and straw coloured)

    International Nuclear Information System (INIS)

    Guzulla, M. F.; Sanchez, E.; Gonzalez, J. M.; Orduna, M.

    2014-01-01

    Bio colonization of building materials is a critical problem for the durability of constructions. Industrial experience shows that straw coloured roofing tiles are more prone to colonization than red roofing tiles, even having similar characteristics. The aim of this work is to explain the difference of bio colonization between different colour roofing tiles. The chemical composition of the surface of straw coloured and red roofing tiles, the phase composition and the microstructure of the roofing tiles were determined by WD-XRF, XRD and SEM-EDX, respectively. The pore size distribution was carried out by Hg porosimetry. The solubility was studied by determining the soluble salts (Ca, Mg, Na, K, Cl and SO 4 2-) by ICP-OES and ionic chromatography. Roofing tile bio receptivity was evaluated by determining fluorescence intensity using a pulse amplitude- modulated (PAM) fluoro meter, and cyanobacteria Oscillator sp. The results obtained show higher concentration of calcium and sulphur in straw coloured roofing tiles surface, and higher solubility than red roofing tiles. Moreover, according to the results obtained in bio receptivity assays, straw coloured roofing tiles are more prone to colonization than red roofing tiles, so, there is a relationship between surface properties of roofing tiles and bio colonization, as it is observed in industrial products. (Author)

  4. The Metric of Colour Space

    DEFF Research Database (Denmark)

    Gravesen, Jens

    2015-01-01

    and found the MacAdam ellipses which are often interpreted as defining the metric tensor at their centres. An important question is whether it is possible to define colour coordinates such that the Euclidean distance in these coordinates correspond to human perception. Using cubic splines to represent......The space of colours is a fascinating space. It is a real vector space, but no matter what inner product you put on the space the resulting Euclidean distance does not correspond to human perception of difference between colours. In 1942 MacAdam performed the first experiments on colour matching...

  5. UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry in the diagnostics of alopecia

    Science.gov (United States)

    Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.

    2016-04-01

    Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.

  6. Colour pyrometer. Farbpyrometer

    Energy Technology Data Exchange (ETDEWEB)

    Luhleich, H; Suetterlin, L; Borchers, D; Pflaum, P

    1980-12-11

    The colour pyrometer according to the invention, in which two beams of limited wavelength from the incoming beam of light are filtered through a chopper with two colour filters of the same diameter rotating round and axis, and are taken to a photo-electric element, from the output signals of which a quotient proportional to the surface temperature of the object is formed in an electrical network, is characterized by the fact that the colour filters in the cylinder wall are arranged at a right angle to each other in a drum rotating around the cylinder axis transverse to the incoming light beam, and are parallel to the axis of rotation, and that the drum wall has openings in the sides diametrically opposite the filters.

  7. Attentional capture by masked colour singletons.

    Science.gov (United States)

    Ansorge, Ulrich; Horstmann, Gernot; Worschech, Franziska

    2010-09-15

    We tested under which conditions a colour singleton of which an observer is unaware captures attention. To prevent visual awareness of the colour singleton, we used backward masking. We find that a masked colour singleton cue captures attention if it matches the observer's goal to search for target colours but not if it is task-irrelevant. This is also reflected in event-related potentials to the visible target: the masked goal-matching cue elicits an attentional potential (N2pc) in a target search task. By contrast, a non-matching but equally strong masked colour singleton cue failed to elicit a capture effect and an N2pc. Results are discussed with regard to currently pertaining conceptions of attentional capture by colour singletons. Copyright 2010 Elsevier Ltd. All rights reserved.

  8. Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja

    Directory of Open Access Journals (Sweden)

    Wanderlei de Moraes

    2017-03-01

    Full Text Available Twenty harpy eagles (Harpia harpyja without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI and pulsatility index (PI were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation.

  9. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  10. An unconventional colour superconductor

    International Nuclear Information System (INIS)

    Huang Mei

    2007-01-01

    Superfluidity, or superconductivity with mismatched Fermi momenta, appears in many systems such as charge-neutral dense quark matter, asymmetric nuclear matter, and in imbalanced cold atomic gases. The mismatch plays the role of breaking the Cooper pairing, and the pair-breaking state cannot be properly described in the framework of standard BCS theory. I give a brief review on recent theoretical developments in understanding unconventional colour superconductivity, including a gapless colour superconductor, chromomagnetic instabilities and the Higgs instability in the gapless phase. I also introduce a possible new framework for describing an unconventional colour superconductor

  11. What triggers colour change? Effects of background colour and temperature on the development of an alpine grasshopper.

    Science.gov (United States)

    Valverde, J Pablo; Schielzeth, Holger

    2015-08-21

    Colour polymorphisms are a fascinating facet of many natural populations of plants and animals, and the selective processes that maintain such variation are as relevant as the processes which promote their development. Orthoptera, the insect group that encompasses grasshoppers and bush crickets, includes a particularly large number of species that are colour polymorphic with a marked green-brown polymorphism being particularly widespread. Colour polymorphism has been associated with the need for crypsis and background matching and background-dependent homochromy has been described in a few species. However, when and how different environmental conditions influence variation in colour remains poorly understood. Here we test for effects of background colour and ambient temperature on the occurrence of colour morph switches (green to brown or brown to green) and developmental darkening in the alpine dwelling club-legged grasshopper Gomphocerus sibiricus. We monitored individually housed nymphae across three of their four developmental stages and into the first week after final ecdysis. Our data show an absence of colour morph switches in G. sibiricus, without a single switch observed in our sample. Furthermore, we test for an effect of temperature on colouration by manipulating radiant heat, a limiting factor in alpine habitats. Radiant heat had a significant effect on developmental darkening: individuals under low radiant heat tended to darken, while individuals under high radiant heat tended to lighten within nymphal stages. Young imagoes darkened under either condition. Our results indicate a plastic response to a variable temperature and indicate that melanin, a multipurpose pigment responsible for dark colouration and presumed to be costly, seems to be strategically allocated according to the current environmental conditions. Unlike other orthopterans, the species is apparently unable to switch colour morphs (green/brown) during development, suggesting that

  12. Determinants of Colour Constancy and the Blue Bias

    Science.gov (United States)

    Gegenfurtner, Karl

    2017-01-01

    We investigated several sensory and cognitive determinants of colour constancy across 40 illumination hues. In the first experiment, we measured colour naming for the illumination and for the colour induced by the illumination on the colorimetric grey. Results confirmed that the induced colours are approximately complementary to the colour of the illumination. In the second experiment, we measured colour constancy using achromatic adjustments. Average colour constancy was perfect under the blue daylight illumination and decreased in colour directions away from the blue daylight illumination due to undershooting and a strong blue bias. Apart from this blue bias, colour constancy was not related to illumination discrimination and to chromatic detection measured previously with the same setup and stimuli. We also observed a strong negative relationship between the degree of colour constancy and the consensus of naming the illumination colour. Constancy coincided with a low naming consensus, in particular because bluish illumination colours were sometimes seen as achromatic. Blue bias and category consensus alone explained >68%, and all determinants together explained >94% of the variance of achromatic adjustments. These findings suggest that colour constancy is optimised for blue daylight. PMID:29348910

  13. Conspicuous plumage colours are highly variable.

    Science.gov (United States)

    Delhey, Kaspar; Szecsenyi, Beatrice; Nakagawa, Shinichi; Peters, Anne

    2017-01-25

    Elaborate ornamental traits are often under directional selection for greater elaboration, which in theory should deplete underlying genetic variation. Despite this, many ornamental traits appear to remain highly variable and how this essential variation is maintained is a key question in evolutionary biology. One way to address this question is to compare differences in intraspecific variability across different types of traits to determine whether high levels of variation are associated with specific trait characteristics. Here we assess intraspecific variation in more than 100 plumage colours across 55 bird species to test whether colour variability is linked to their level of elaboration (indicated by degree of sexual dichromatism and conspicuousness) or their condition dependence (indicated by mechanism of colour production). Conspicuous colours had the highest levels of variation and conspicuousness was the strongest predictor of variability, with high explanatory power. After accounting for this, there were no significant effects of sexual dichromatism or mechanisms of colour production. Conspicuous colours may entail higher production costs or may be more sensitive to disruptions during production. Alternatively, high variability could also be related to increased perceptual difficulties inherent to discriminating highly elaborate colours. Such psychophysical effects may constrain the exaggeration of animal colours. © 2017 The Author(s).

  14. A new universal colour image fidelity metric

    NARCIS (Netherlands)

    Toet, A.; Lucassen, M.P.

    2003-01-01

    We extend a recently introduced universal grayscale image quality index to a newly developed perceptually decorrelated colour space. The resulting colour image fidelity metric quantifies the distortion of a processed colour image relative to its original version. We evaluated the new colour image

  15. Effect of Pigment Colouring on Physico-mechanical Properties of Hardened Cement Paste and Response of Colour Intensity to UV Radiation

    International Nuclear Information System (INIS)

    Khattab, M.M.; Abdel-Rahman, H.A.; Hassan, M.S.

    2010-01-01

    In this work, different ratios of pigment colour was mixed with cement paste during mixing. The pigment colour used was Phthalocyanine Green. The effect of pigment colouring on hardened cement paste (HCP) was characterized in terms of compressive strength, IR spectroscopic analysis and X-ray diffraction. In addition, the effect of UV radiation on the colour strength of hardened cement paste/pigment colour composites was investigated. The results indicated that the increase in the ratio of pigment colour was accompanied with a slight decrease in the values of compressive strength. The exposure of the coloured hardened cement paste to UV radiation for long lengths of time causes a little effect on the colour intensity

  16. Analisis Variasi Warna Terhadap Kualitas Daya Serap dan Kuat Tarik Tissue Napkin Paper

    Directory of Open Access Journals (Sweden)

    Ragil Meita Alfathy

    2017-10-01

    Full Text Available Tisu telah menjadi kebutuhan sehari–hari masyarakat dunia karena tisu merupakan benda pembersih praktis yang dapat dibawa kemana–mana. Inovasi yang dilakukan oleh para produsen adalah dengan memberikan corak motif bahkan warna untuk menambah nilai estetika dari tisu terutama pada tissue napkin paper atau kertas tisu serbet. Seiring berjalannya waktu, nilai estetika pada tissue napkin paper menjadi pertimbangan utama konsumen dalam pemilihan tisu dibandingkan fungsi utama kertas tissue napkin paper sebagai alat pembersih sehingga konsumen melupakan kualitas fisik dari tissue napkin paper. Tujuan penelitian ini untuk mengidentifikasi potensi perbedaan kuat tarik dan daya serap tissue napkin paper dengan dan tanpa colourant. Tissue napkin paper dihitung volume air yang terserap secara radial dan gaya yang dibutuhkan tisu dengan luas permukaan 0,042m2  untuk merobeknya, sehingga diketahui bahwa tissue napkin berwana merah, hijau, kuning dan putih memiliki persentase kualitas daya serap secara berturut-turut 38,89%, 42,78%, 41,67%, 46,67%  dan daya kuat tarik 78,3N/m2; 103,3N/m2; 140,4N/m2; 141,5N/m2. Colourant mengubah struktur pore menjadi lebih sempit dan jarak permukaan serat selulosa menjadi semakin panjang. Sehingga terjadi penurunan daya serap dan kuat tarik tissue napkins paper dengan colourant meskipun tidak dalam taraf yang signifikan.

  17. The unsuitability of html-based colour charts for estimating animal colours – a comment on Berggren and Merilä (2004

    Directory of Open Access Journals (Sweden)

    Cuthill Innes C

    2005-08-01

    Full Text Available Abstract Background A variety of techniques are used to study the colours of animal signals, including the use of visual matching to colour charts. This paper aims to highlight why they are generally an unsatisfactory tool for the measurement and classification of animal colours and why colour codes based on HTML (really RGB standards, as advocated in a recent paper, are particularly inappropriate. There are many theoretical arguments against the use of colour charts, not least that human colour vision differs markedly from that of most other animals. However, the focus of this paper is the concern that, even when applied to humans, there is no simple 1:1 mapping from an RGB colour space to the perceived colours in a chart (the results are both printer- and illumination-dependent. We support our criticisms with data from colour matching experiments with humans, involving self-made, printed colour charts. Results Colour matching experiments with printed charts involving 11 subjects showed that the choices made by individuals were significantly different between charts that had exactly the same RGB values, but were produced from different printers. Furthermore, individual matches tended to vary under different lighting conditions. Spectrophotometry of the colour charts showed that the reflectance spectra of the charts varied greatly between printers and that equal steps in RGB space were often far from equal in terms of reflectance on the printed charts. Conclusion In addition to outlining theoretical criticisms of the use of colour charts, our empirical results show that: individuals vary in their perception of colours, that different printers produce strikingly different results when reproducing what should be the same chart, and that the characteristics of the light irradiating the surface do affect colour perception. Therefore, we urge great caution in the use of colour charts to study animal colour signals. They should be used only as a last

  18. IRIS COLOUR CLASSIFICATION SCALES--THEN AND NOW.

    Science.gov (United States)

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual's eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale.

  19. Independent effects of colour on object identification and memory.

    Science.gov (United States)

    Lloyd-Jones, Toby J; Nakabayashi, Kazuyo

    2009-02-01

    We examined the effects of colour on object identification and memory using a study-test priming procedure with a coloured-object decision task at test (i.e., deciding whether an object is correctly coloured). Objects were selected to have a single associated colour and were either correctly or incorrectly coloured. In addition, object shape and colour were either spatially integrated (i.e., colour fell on the object surface) or spatially separated (i.e., colour formed the background to the object). Transforming the colour of an object from study to test (e.g., from a yellow banana to a purple banana) reduced priming of response times, as compared to when the object was untransformed. This utilization of colour information in object memory was not contingent upon colour falling on the object surface or whether the resulting configuration was of a correctly or incorrectly coloured object. In addition, we observed independent effects of colour on response times, whereby coloured-object decisions were more efficient for correctly than for incorrectly coloured objects but only when colour fell on the object surface. These findings provide evidence for two distinct mechanisms of shape-colour binding in object processing.

  20. Scalable, full-colour and controllable chromotropic plasmonic printing

    Science.gov (United States)

    Xue, Jiancai; Zhou, Zhang-Kai; Wei, Zhiqiang; Su, Rongbin; Lai, Juan; Li, Juntao; Li, Chao; Zhang, Tengwei; Wang, Xue-Hua

    2015-01-01

    Plasmonic colour printing has drawn wide attention as a promising candidate for the next-generation colour-printing technology. However, an efficient approach to realize full colour and scalable fabrication is still lacking, which prevents plasmonic colour printing from practical applications. Here we present a scalable and full-colour plasmonic printing approach by combining conjugate twin-phase modulation with a plasmonic broadband absorber. More importantly, our approach also demonstrates controllable chromotropic capability, that is, the ability of reversible colour transformations. This chromotropic capability affords enormous potentials in building functionalized prints for anticounterfeiting, special label, and high-density data encryption storage. With such excellent performances in functional colour applications, this colour-printing approach could pave the way for plasmonic colour printing in real-world commercial utilization. PMID:26567803

  1. Grapheme-colour synaesthesia improves detection of embedded shapes, but without pre-attentive 'pop-out' of synaesthetic colour.

    Science.gov (United States)

    Ward, Jamie; Jonas, Clare; Dienes, Zoltan; Seth, Anil

    2010-04-07

    For people with synaesthesia letters and numbers may evoke experiences of colour. It has been previously demonstrated that these synaesthetes may be better at detecting a triangle made of 2s among a background of 5s if they perceive 5 and 2 as having different synaesthetic colours. However, other studies using this task (or tasks based on the same principle) have failed to replicate the effect or have suggested alternative explanations of the effect. In this study, we repeat the original study on a larger group of synaesthetes (n = 36) and include, for the first time, an assessment of their self-reported colour experiences. We show that synaesthetes do have a general advantage over controls on this task. However, many synaesthetes report no colour experiences at all during the task. Synaesthetes who do report colour typically experience around one third of the graphemes in the display as coloured. This is more consistent with theories of synaesthesia in which spatial attention needs to be deployed to graphemes for conscious colour experiences to emerge than the interpretation based on 'pop-out'.

  2. n-Colour even self-inverse compositions

    Indian Academy of Sciences (India)

    An -colour even self-inverse composition is defined as an -colour self-inverse composition with even parts. In this paper, we get generating functions, explicit formulas and recurrence formulas for -colour even self-inverse compositions. One new binomial identity is also obtained.

  3. A Bayesian Model of the Memory Colour Effect.

    Science.gov (United States)

    Witzel, Christoph; Olkkonen, Maria; Gegenfurtner, Karl R

    2018-01-01

    According to the memory colour effect, the colour of a colour-diagnostic object is not perceived independently of the object itself. Instead, it has been shown through an achromatic adjustment method that colour-diagnostic objects still appear slightly in their typical colour, even when they are colourimetrically grey. Bayesian models provide a promising approach to capture the effect of prior knowledge on colour perception and to link these effects to more general effects of cue integration. Here, we model memory colour effects using prior knowledge about typical colours as priors for the grey adjustments in a Bayesian model. This simple model does not involve any fitting of free parameters. The Bayesian model roughly captured the magnitude of the measured memory colour effect for photographs of objects. To some extent, the model predicted observed differences in memory colour effects across objects. The model could not account for the differences in memory colour effects across different levels of realism in the object images. The Bayesian model provides a particularly simple account of memory colour effects, capturing some of the multiple sources of variation of these effects.

  4. Game Coloured Petri Nets

    DEFF Research Database (Denmark)

    Westergaard, Michael

    2006-01-01

    This paper introduces the notion of game coloured Petri nets. This allows the modeler to explicitly model what parts of the model comprise the modeled system and what parts are the environment of the modeled system. We give the formal definition of game coloured Petri nets, a means of reachability...... analysis of this net class, and an application of game coloured Petri nets to automatically generate easy-to-understand visualizations of the model by exploiting the knowledge that some parts of the model are not interesting from a visualization perspective (i.e. they are part of the environment...

  5. Thirteen-colour photometry of Be stars

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, M; Schuster, W J [Universidad Nacional Autonoma de Mexico, Mexico City. Inst. de Astronomia

    1981-01-01

    Thirteen-colour photometry made at the San Pedro Martir Observatory in Baja California, for a number of spectroscopically variable Be and shell stars is presented. Several of these stars also show photometric variability in the ultraviolet and/or infrared over a time base of two to three years. We analyze the more interesting stars in terms of colour-colour diagrams, colour excesses, spectral characteristics and changes in their energy distributions. Prospects for future research are discussed.

  6. Thirteen-colour photometry of Be stars

    International Nuclear Information System (INIS)

    Alvarez, M.; Schuster, W.J.

    1981-01-01

    Thirteen-colour photometry made at the San Pedro Martir Observatory in Baja California, for a number of spectroscopically variable Be and shell stars is presented. Several of these stars also show photometric variability in the ultraviolet and/or infrared over a time base of two to three years. We analyze the more interesting stars in terms of colour-colour diagrams, colour excesses, spectral characteristics and changes in their energy distributions. Prospects for future research are discussed. (author)

  7. Colour vision and computer-generated images

    International Nuclear Information System (INIS)

    Ramek, Michael

    2010-01-01

    Colour vision deficiencies affect approximately 8% of the male and approximately 0.4% of the female population. In this work, it is demonstrated that computer generated images oftentimes pose unnecessary problems for colour deficient viewers. Three examples, the visualization of molecular structures, graphs of mathematical functions, and colour coded images from numerical data are used to identify problematic colour combinations: red/black, green/black, red/yellow, yellow/white, fuchsia/white, and aqua/white. Alternatives for these combinations are discussed.

  8. The colour of gender stereotyping.

    Science.gov (United States)

    Cunningham, Sheila J; Macrae, C Neil

    2011-08-01

    Despite legislative attempts to eliminate gender stereotyping from society, the propensity to evaluate people on the basis of their sex remains a pernicious social problem. Noting the critical interplay between cultural and cognitive factors in the establishment of stereotypical beliefs, the current investigation explored the extent to which culturally transmitted colour-gender associations (i.e., pink is for girls, blue is for boys) set the stage for the automatic activation and expression of gender stereotypes. Across six experiments, the results demonstrated that (1) consumer choice for children's goods is dominated by gender-stereotyped colours (Experiment 1); (2) colour-based stereotypic associations guide young children's behaviour (Experiment 2); (3) colour-gender associations automatically activate associated stereotypes in adulthood (Experiments 3-5); and (4) colour-based stereotypic associations bias impressions of male and female targets (Experiment 6). These findings indicate that, despite prohibitions against stereotyping, seemingly innocuous societal practices may continue to promote this mode of thought. ©2011 The British Psychological Society.

  9. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  10. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  11. Colour chemistry

    International Nuclear Information System (INIS)

    Hong-Mo, C.

    1978-10-01

    Colour is now popularly believed to be the basis of strong interactions and as evidence for such a fundamental new degree of freedom one should expect an entirely new class of phenomena qualitatively different from those in a colourless world. One place to seek such manifestations is in spectroscopy, where a new degree of freedom should lead to a richer spectrum. this approach is here discussed with especial reference to the case of diquoniums. The very existence of M-diquoniums, whose spectrum has been calculated and is shown, would be a verification of colour. (U.K.)

  12. Repeatability indices for the Adams D-15 test for colour-normal and colour-defective adults.

    Science.gov (United States)

    Hovis, Jeffery K; Ramaswamy, Shankaran; Anderson, Matthew

    2004-07-01

    The Adams desaturated D-15 test was administered to individuals with normal colour vision or with congenital red-green colour vision defects to establish the repeatability of the test. One hundred subjects with normal colour vision and 64 subjects with defective colour vision participated in the study. Results were analysed from two different sessions to determine the repeatability of the test for different pass/fail criteria. The test was scored using both visual inspection of the score sheet and the modified Colour Difference Vector analysis (CDV) program. For both subject groups, the repeatability was lowest when a perfect arrangement was required for a pass and improved as more errors were allowed. The improvement in repeatability was greatest as the failure criterion changed from 'any mistake' to 'more than two crossings'. The kappa coefficient for the reliability of the defect classification was 0.38 for visual inspection and 0.59 for the CDV analysis. All the protans who failed the test at both sessions were classified correctly. Approximately 98 per cent of the colour-normals and 82 per cent of the colour-defectives would have the same pass/fail outcome on the Adams D-15 test conducted several days apart when the failure criterion was either one or more or two or more crossings. Individuals who make less than four crossings on the Adams D-15 should repeat the test to ensure confidence in the pass/fail result.

  13. Colouring outside the lines

    Science.gov (United States)

    Commissariat, Tushna

    2017-10-01

    Walk into a bookshop today, or even a gift shop, and you will most likely come across an entire section of colouring books for adults. Visions of Numberland: a Colouring Journey Through the Mysteries of Maths by Alex Bellos and Edmund Harriss is one such book.

  14. The Categorisation of Non-Categorical Colours: A Novel Paradigm in Colour Perception

    Science.gov (United States)

    Cropper, Simon J.; Kvansakul, Jessica G. S.; Little, Daniel R.

    2013-01-01

    In this paper, we investigate a new paradigm for studying the development of the colour ‘signal’ by having observers discriminate and categorize the same set of controlled and calibrated cardinal coloured stimuli. Notably, in both tasks, each observer was free to decide whether two pairs of colors were the same or belonged to the same category. The use of the same stimulus set for both tasks provides, we argue, an incremental behavioural measure of colour processing from detection through discrimination to categorisation. The measured data spaces are different for the two tasks, and furthermore the categorisation data is unique to each observer. In addition, we develop a model which assumes that the principal difference between the tasks is the degree of similarity between the stimuli which has different constraints for the categorisation task compared to the discrimination task. This approach not only makes sense of the current (and associated) data but links the processes of discrimination and categorisation in a novel way and, by implication, expands upon the previous research linking categorisation to other tasks not limited to colour perception. PMID:23536899

  15. Exposure of Polish children to Southampton food colours.

    Science.gov (United States)

    Gajda-Wyrębek, J; Kuźma, K; Świtka, A; Jarecka, J; Beresińska, M; Postupolski, J

    2017-01-01

    A study published in 2007 showed that the intake of six food colours (the so-called 'Southampton colours') may have an adverse effect on activity and attention in children. The present study set out to assess the exposure of Polish children (3 and 8-9 years old, n = 149) to six of the target colours. Two methods were used to evaluate colour consumption by children: scenario 1 using the maximum permitted levels (MPLs) and actual food consumption data; and scenario 2 using the actual levels in food and actual food consumption data. The data on the actual consumption of food containing the colours was collected using a 7-day questionnaire survey. The results of laboratory analysis of food consumed by children provided data on the actual levels of the colours in food. Consumption of the colours estimated by scenario 1 in any case did not exceed the acceptable daily intakes (ADIs) of the colours in both age groups of children. For more refined colour intake (scenario 2), isolated cases exceeding the ADI were recorded for four colours, but assuming that manufacturers comply with the current legislation on MPL of colours in food, the intake of the colours assessed in scenario 2 should not be a reason for exceeding of ADIs for the target food colours.

  16. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  17. A model for post-occlusive reactive hyperemia as measured with laser-Doppler perfusion monitoring

    NARCIS (Netherlands)

    de Mul, FFM; Morales, F; Smit, AJ; Graaff, R

    To facilitate the quantitative analysis of post-occlusive reactive fiyper emia (POR11), measured with laser-Doppler perfusion monitoring (LDPM) on extremities, we present a flow model for the dynamics of the perfusion of the tissue during PORH, based on three parameters: two time constants (tau(1)

  18. [Historical Development of the Wool and Colour Plate Tests for Screening for Colour Vision Deficiencies in German Speaking Countries].

    Science.gov (United States)

    Kuchenbecker, J

    2017-07-01

    Colour vision is a complex visual function that can be affected by congenital and/or acquired disorders. The frequency of congenital colour vision deficiencies has been investigated in rail and navy staff since the 1870s. Various test methods have been developed. Wool tests, flor contrast tests and colour plate tests have been used. A published colour plate test, based on Stilling's pseudo-isochromatic plates in combination with a flor contrast test, has been a common screening method for colour vision testing in German-speaking countries. This test is intended to detect congenital and acquired colour vision deficiencies in a simple and safe manner. More modern options, such as Internet and tablet PC have technical limitations, but will increasingly be used for screening for colour vision deficiencies. Georg Thieme Verlag KG Stuttgart · New York.

  19. Exploring the benefit of synaesthetic colours: testing for "pop-out" in individuals with grapheme-colour synaesthesia.

    Science.gov (United States)

    Rich, Anina N; Karstoft, Karen-Inge

    2013-01-01

    In grapheme-colour synaesthesia, letters, numbers, and words elicit involuntary colour experiences. Recently, there has been much emphasis on individual differences and possible subcategories of synaesthetes with different underlying mechanisms. In particular, there are claims that for some, synaesthesia occurs prior to attention and awareness of the inducing stimulus. We first characterized our sample using two versions of the "Synaesthetic Congruency Task" to distinguish "projector" and "associator" synaesthetes who may differ in the extent to which their synaesthesia depends on attention and awareness. We then used a novel modification of the "Embedded Figures Task" that included a set-size manipulation to look for evidence of preattentive "pop-out" from synaesthetic colours, at both a group and an individual level. We replicate an advantage for synaesthetes over nonsynaesthetic controls on the Embedded Figures Task in accuracy, but find no support for pop-out of synaesthetic colours. We conclude that grapheme-colour synaesthetes are fundamentally similar in their visual processing to the general population, with the source of their unusual conscious colour experiences occurring late in the cognitive hierarchy.

  20. Brown colour in natural diamond and interaction between the brown related and other colour-inducing defects

    International Nuclear Information System (INIS)

    Fisher, D; Sibley, S J; Kelly, C J

    2009-01-01

    Absorption spectroscopy results on a range of type II diamonds are presented which enable the electronic states associated with them to be mapped out. High pressure, high temperature treatment of brown type IIa diamonds has enabled an activation energy for the removal of the brown colour of 8.0 ± 0.3 eV to be determined and this is consistent with expectations associated with the currently accepted vacancy cluster model for the defect. Theoretical calculations suggest that this defect will generate partially filled gap states about 1 eV above the valence band. Data on the photochromic behaviour of bands producing pink colour and their relation to brown colour are presented; these suggest that the pink bands are produced from two independent transitions with ground states close to each other just below the middle of the band gap. Compensation of neutral boron by charge transfer from states associated with brown colour is demonstrated via the correlated increase in neutral boron and decrease in brown colour on high pressure, high temperature treatment to remove the defects causing the brown colour.

  1. Colours as Non-Verbal Signs on Packages

    OpenAIRE

    Kauppinen, Hannele

    2005-01-01

    Colour is an essential aspect of our daily life, and still, it is a neglected issue within marketing research. The main reason for studying colours is to understand the impact of colours on consumer behaviour, and thus, colours should be studied when it comes to branding, advertising, packages, interiors, and the clothes of the employees, for example. This was an exploratory study about the impact of colours on packages. The focus was on low-involvement purchasing, where the consumer puts...

  2. Colour-grapheme synaesthesia affects binocular vision

    Directory of Open Access Journals (Sweden)

    Chris L.E. Paffen

    2011-11-01

    Full Text Available In colour-grapheme synaesthesia, non-coloured graphemes are perceived as being inherently coloured. In recent years, it has become evident that synaesthesia-inducing graphemes can affect visual processing in a manner comparable to real, physical colours. Here, we exploit the phenomenon of binocular rivalry in which incompatible images presented dichoptically compete for conscious expression. Importantly, the competition only arises if the two images are sufficiently different; if the difference between the images is small, the images will fuse into a single mixed percept. We show that achromatic graphemes that induce synaesthetic colour percepts evoke binocular rivalry, while without the synaesthetic percept, they do not. That is, compared to achromatically perceived graphemes, synaesthesia-inducing graphemes increase the predominance of binocular rivalry over binocular fusion. This finding shows that the synaesthetic colour experience can provide the conditions for evoking binocular rivalry, much like stimulus features that induce rivalry in normal vision.

  3. Laser-induced plasmonic colours on metals

    Science.gov (United States)

    Guay, Jean-Michel; Calà Lesina, Antonino; Côté, Guillaume; Charron, Martin; Poitras, Daniel; Ramunno, Lora; Berini, Pierre; Weck, Arnaud

    2017-07-01

    Plasmonic resonances in metallic nanoparticles have been used since antiquity to colour glasses. The use of metal nanostructures for surface colourization has attracted considerable interest following recent developments in plasmonics. However, current top-down colourization methods are not ideally suited to large-scale industrial applications. Here we use a bottom-up approach where picosecond laser pulses can produce a full palette of non-iridescent colours on silver, gold, copper and aluminium. We demonstrate the process on silver coins weighing up to 5 kg and bearing large topographic variations (~1.5 cm). We find that colours are related to a single parameter, the total accumulated fluence, making the process suitable for high-throughput industrial applications. Statistical image analyses of laser-irradiated surfaces reveal various nanoparticle size distributions. Large-scale finite-difference time-domain computations based on these nanoparticle distributions reproduce trends seen in reflectance measurements, and demonstrate the key role of plasmonic resonances in colour formation.

  4. Coloured phase singularities

    International Nuclear Information System (INIS)

    Berry, M.V.

    2002-01-01

    For illumination with white light, the spectra near a typical isolated phase singularity (nodal point of the component wavelengths) can be described by a universal function of position, up to linear distortion and a weak dependence on the spectrum of the source. The appearance of the singularity when viewed by a human observer is predicted by transforming the spectrum to trichromatic variables and chromaticity coordinates, and then rendering the colours, scaled to constant luminosity, on a computer monitor. The pattern far from the singularity is a white that depends on the source temperature, and the centre of the pattern is flanked by intensely coloured 'eyes', one orange and one blue, separated by red, and one of the eyes is surrounded by a bright white circle. Only a small range of possible colours appears near the singularity; in particular, there is no green. (author)

  5. Colour Vision Impairment in Young Alcohol Consumers.

    Directory of Open Access Journals (Sweden)

    Alódia Brasil

    Full Text Available Alcohol consumption among young adults is widely accepted in modern society and may be the starting point for abusive use of alcohol at later stages of life. Chronic alcohol exposure can lead to visual function impairment. In the present study, we investigated the spatial luminance contrast sensitivity, colour arrangement ability, and colour discrimination thresholds on young adults that weekly consume alcoholic beverages without clinical concerns. Twenty-four young adults were evaluated by an ophthalmologist and performed three psychophysical tests to evaluate their vision functions. We estimated the spatial luminance contrast sensitivity function at 11 spatial frequencies ranging from 0.1 to 30 cycles/degree. No difference in contrast sensitivity was observed comparing alcohol consumers and control subjects. For the evaluation of colour vision, we used the Farnsworth-Munsell 100 hue test (FM 100 test to test subject's ability to perform a colour arrangement task and the Mollon-Reffin test (MR test to measure subject's colour discrimination thresholds. Alcohol consumers made more mistakes than controls in the FM100 test, and their mistakes were diffusely distributed in the FM colour space without any colour axis preference. Alcohol consumers also performed worse than controls in the MR test and had higher colour discrimination thresholds compared to controls around three different reference points of a perceptually homogeneous colour space, the CIE 1976 chromaticity diagram. There was no colour axis preference in the threshold elevation observed among alcoholic subjects. Young adult weekly alcohol consumers showed subclinical colour vision losses with preservation of spatial luminance contrast sensitivity. Adolescence and young adult age are periods of important neurological development and alcohol exposure during this period of life might be responsible for deficits in visual functions, especially colour vision that is very sensitive to

  6. Human colour in mate choice and competition.

    Science.gov (United States)

    Rowland, Hannah M; Burriss, Robert P

    2017-07-05

    The colour of our skin and clothing affects how others perceive us and how we behave. Human skin colour varies conspicuously with genetic ancestry, but even subtle changes in skin colour due to diet, blood oxygenation and hormone levels influence social perceptions. In this review, we describe the theoretical and empirical frameworks in which human colour is researched. We explore how subtle skin colour differences relate to judgements of health and attractiveness. Also, because humans are one of the few organisms able to manipulate their apparent colour, we review how cosmetics and clothing are implicated in courtship and competition, both inside the laboratory and in the real world. Research on human colour is in its infancy compared with human psychophysics and colour research in non-human animals, and hence we present best-practice guidelines for methods and reporting, which we hope will improve the validity and reproducibility of studies on human coloration.This article is part of the themed issue 'Animal coloration: production, perception, function and application'. © 2017 The Author(s).

  7. Colour Perception on Facial Expression towards Emotion

    Directory of Open Access Journals (Sweden)

    Rubita Sudirman

    2012-12-01

    Full Text Available This study is to investigate human perceptions on pairing of facial expressions of emotion with colours. A group of 27 subjects consisting mainly of younger and Malaysian had participated in this study. For each of the seven faces, which expresses the basic emotions neutral, happiness, surprise, anger, disgust, fear and sadness, a single colour is chosen from the eight basic colours for the match of best visual look to the face accordingly. The different emotions appear well characterized by a single colour. The approaches used in this experiment for analysis are psychology disciplines and colours engineering. These seven emotions are being matched by the subjects with their perceptions and feeling. Then, 12 male and 12 female data are randomly chosen from among the previous data to make a colour perception comparison between genders. The successes or failures in running of this test depend on the possibility of subjects to propose their every single colour for each expression. The result will translate into number and percentage as a guide for colours designers and psychology field.

  8. Can tissue spectrophotometry and laser Doppler flowmetry help to identify patients at risk for wound healing disorders after neck dissection?

    Science.gov (United States)

    Rohleder, Nils H; Flensberg, Sandra; Bauer, Florian; Wagenpfeil, Stefan; Wales, Craig J; Koerdt, Steffen; Wolff, Klaus D; Hölzle, Frank; Steiner, Timm; Kesting, Marco R

    2014-03-01

    Microcirculation and oxygen supply in cervical skin were measured with an optical, noninvasive method in patients with or without radiotherapy before neck dissection. The course of wound healing was monitored after the surgical procedure to identify predictive factors for postoperative wound healing disorders. Tissue spectrophotometry and laser Doppler flowmetry were used to determine capillary oxygen saturation, hemoglobin concentration, blood flow, and blood velocity at 2-mm and 8-mm depths in the cervical skin of 91 patients before neck dissection in a maxillofacial unit of a university hospital in Munich, Germany. Parameters were evaluated for differences between patients with irradiation (24) and without (67) and patients with wound healing disorders (25) and without (66) (univariate or multivariate statistical analyses). Velocity at 2 mm was lower in irradiated skin (P = .016). Flow at 2 mm was higher in patients with wound healing disorders (P = .018). High flow values could help to identify patients at risk for cervical wound healing disorders. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. An RGB Approach to Prismatic Colours

    Science.gov (United States)

    Theilmann, Florian; Grusche, Sascha

    2013-01-01

    Teaching prismatic colours usually boils down to establishing the take-home message that white light consists of "differently refrangible" coloured rays. This approach explains the classical spectrum of seven colours but has its limitations, e.g. in discussing spectra from setups with higher resolution or in understanding the well…

  10. Colour development in the apple orchard

    NARCIS (Netherlands)

    Tijskens, L.M.M.; Unuk, T.; Stanislav Tojnko, S.; Hribar, J.; Simcic, M.

    2011-01-01

    Colour is traditionally one of the important appearance features of all fruit for consumers in deciding to buy them. Colour is therefore important in the postharvest supply chain. But where does that colour of fruit come from? Clearly the period of growing and the circumstances during growth are

  11. Colour From the Perspective of Hadith: an Overview

    Directory of Open Access Journals (Sweden)

    Zainan Nazri Mohd Khairul Nizam

    2015-01-01

    Full Text Available Colour is mentioned a few times in the Prophetic Traditions, signifying its values and symbolic representation for the people. The Prophet PBUH highlighted the significance of certain colours by describing his preferred colours for his clothing and he also approved or discouraged the usage of certain colours. Among the colours that are specifically mentioned and found in the hadith are white, red, green, black and yellow. These colours give different connotations as they were used in the Prophet’s attires during battles and other occasions; and some bring about specific understanding, as stated by the Prophet PBUH. Interestingly, the use of certain colours as found in the hadith corresponds to that mentioned in the Qur’an. Thus, this paper will observe the discussion among Muhaddithin regarding to the topic of colours in terms of its definition, function, significance and impact on the human life. The variety of meaning and understanding of colours according to different perspectives and cultures will also be discussed. The implications of using specific colours psychologically and scientifically will also be exposed in order to discover the connection between colours in the Prophetic Traditions and in our contemporary life.

  12. New particles and breaking the colour symmetry

    International Nuclear Information System (INIS)

    Krolikowski, W.

    1975-01-01

    In the framework of one-gluon-exchange static forces mediated by a colour octet or nonet of vector gluons, we discuss quark binding in coloured-meson states and its connection with breaking the colour symmetry. A possible identification of psi (3.1), psi(3.7) and the broad bump at 4.1 GeV with some coloured bound states of quarks and antiquarks is pointed out. This identification implies the existence of a second bump in the region of 5 GeV. The general conclusion of the paper is that the colour interpretation of the new particles may be true only if the colour symmetry is badly broken (provided the considered forces are relevant). (author)

  13. Usefulness of hemodynamically distribution of intranodal vessels in differentiating metastatic neck lymph nodes-value of color doppler and spectral wave sonogram

    International Nuclear Information System (INIS)

    Mumtaz, U.

    2017-01-01

    Objective: To evaluate the diagnostic assessment of enlarged lymph nodes, based on its perfusion pattern by taking tissue diagnosis as gold standard. Study Design: Analytical study. Place and Duration of Study: Departments of Radiology and Pathology, PIMS Hospital, Islamabad, from February to May 2016. Methodology: Color sonography of patients with clinically, palpable cervical lymph nodes were carried by senior trainee under the supervision of senior radiologist. Ultrasound guided tissue diagnosis was obtained in all suspected malignant cases. Histopathology was taken as the gold standard for determining accuracy. Results: Accuracy, sensitivity and specificity, positive and negative predictive values of color Doppler ultrasound in detecting malignant cervical lymphadenopathy was found to be 88.46%, 86.05%, 79.31% and 92.50%, respectively with diagnostic accuracy of 86.95%, when intranodal vascular pattern on color Doppler imaging was analyzed. Using spectral wave indexes, the same values were 92.31%, 90.70%, 85.71%, 95.12%, respectively with overall diagnostic accuracy of 91.30%. Conclusion: Color Doppler sonography is much sensitive borderline than grey scale findings alone. Furthermore, lymph nodes appearing in the detection of malignant nodes on grey scale images can be reliably diagnosed on Doppler scan. (author)

  14. Culture of colour in the city

    Directory of Open Access Journals (Sweden)

    Vasiljević-Tomić Dragana

    2009-01-01

    Full Text Available The phenomenon of colour is examined through the evolution of colour and development of culture of colour, which significantly affects the colouristic priorities of people and the colour of the city itself. The terms functional colour and climate of colour are also considered, as some of the most important characteristics of architectural and urban design practice. The quality of the urban public space is directly predicated by cultural identity, and indirectly by appearance of polychromy in urban public space. The need to improve the quality of life in the city represents one of the key motives for operating in urban space, i.e. commencing the process of architectural and urban designing. Historical architectural policrhomy represents the basis for appearance of colour in public space. The complexity of colouristic attributes of the urban public space is conditioned by the basic characteristics: colouristic priorities, harmony of coloured spatial structures and materials in designing the polychrome ambient in the city. The factors that shape the colouristic ambient of the city are: characteristics of nature and climate, interrelations of colour and shape, as well as the experience of the form of the urban public space while preserving its identity. The acquired experiences point to the possibility of redefining the concepts of urban public space in planning and designing practice. The synthesized knowledge is sublimed through examination of the elasticity of its boundaries in accordance to the preservation of the identity of place and the future transformations of the city as well as of its users. The new principles are formed upon which the transformed model of the urban public space as a polychrome ambient is built.

  15. A Wearable Transcranial Doppler Ultrasound Phased Array System.

    Science.gov (United States)

    Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2018-01-01

     Practical deficiencies related to conventional transcranial Doppler (TCD) sonography have restricted its use and applicability. This work seeks to mitigate several such constraints through the development of a wearable, electronically steered TCD velocimetry system, which enables noninvasive measurement of cerebral blood flow velocity (CBFV) for monitoring applications with limited operator interaction. A highly-compact, discrete prototype system was designed and experimentally validated through flow phantom and preliminary human subject testing. The prototype system incorporates a custom two-dimensional transducer array and multi-channel transceiver electronics, thereby facilitating acoustic beamformation via phased array operation. Electronic steering of acoustic energy enables algorithmic system controls to map Doppler power throughout the tissue volume of interest and localize regions of maximal flow. Multi-focal reception permits dynamic vessel position tracking and simultaneous flow velocimetry over the time-course of monitoring. Experimental flow phantom testing yielded high correlation with concurrent flowmeter recordings across the expected range of physiological flow velocities. Doppler power mapping has been validated in both flow phantom and preliminary human subject testing, resulting in average vessel location mapping times testing. A wearable prototype CBFV measurement system capable of autonomous vessel search and tracking has been presented. Although flow phantom and preliminary human validation show promise, further human subject testing is necessary to compare velocimetry data against existing commercial TCD systems. Additional human subject testing must also verify acceptable vessel search and tracking performance under a variety of subject populations and motion dynamics-such as head movement and ambulation.

  16. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  17. A Bayesian Model of the Memory Colour Effect

    OpenAIRE

    Witzel, Christoph; Olkkonen, Maria; Gegenfurtner, Karl R.

    2018-01-01

    According to the memory colour effect, the colour of a colour-diagnostic object is not perceived independently of the object itself. Instead, it has been shown through an achromatic adjustment method that colour-diagnostic objects still appear slightly in their typical colour, even when they are colourimetrically grey. Bayesian models provide a promising approach to capture the effect of prior knowledge on colour perception and to link these effects to more general effects of cue integration....

  18. A Bayesian model of the memory colour effect.

    OpenAIRE

    Witzel, Christoph; Olkkonen, Maria; Gegenfurtner, Karl R.

    2018-01-01

    According to the memory colour effect, the colour of a colour-diagnostic object is not perceived independently of the object itself. Instead, it has been shown through an achromatic adjustment method that colour-diagnostic objects still appear slightly in their typical colour, even when they are colourimetrically grey. Bayesian models provide a promising approach to capture the effect of prior knowledge on colour perception and to link these effects to more general effects of cue integration....

  19. Colour reconstruction of underwater images

    OpenAIRE

    Hoth, Julian; Kowalczyk, Wojciech

    2017-01-01

    Objects look very different in the underwater environment compared to their appearance in sunlight. Images with correct colouring simplify the detection of underwater objects and may allow the use of visual SLAM algorithms developed for land-based robots underwater. Hence, image processing is required. Current algorithms focus on the colour reconstruction of scenery at diving depth where different colours can still be distinguished. At greater depth this is not the case. In this study it is i...

  20. The Attentional Capture of Colour in Visual Interface Design

    DEFF Research Database (Denmark)

    Andersen, Emil; Maier, Anja

    2017-01-01

    The use of colour is an integral component in visual interface design for creating separation between objects and for conveying meaning. It has previously been established that colours can be separated in a hierarchy of primary colours and secondary colours, and that colours are consistently...... in a controlled environment, in which 11 participants scanned a 20 item display for a coloured target amongst coloured distractors. We found evidence to support that primary colours capture attention significantly more than secondary colours, and inconclusive evidence that colours convey their meaning...... at a sufficiently early level of processing to influence attention. We end by discussing implications of our results for design practice and research in psychology....

  1. Semiquantitative Evaluation of Extrasynovial Soft Tissue Inflammation in the Shoulders of Patients with Polymyalgia Rheumatica and Elderly-Onset Rheumatoid Arthritis by Power Doppler Ultrasound.

    Science.gov (United States)

    Suzuki, Takeshi; Yoshida, Ryochi; Okamoto, Akiko; Seri, Yu

    2017-01-01

    Objectives . To develop a scoring system for evaluating the extrasynovial soft tissue inflammation of the shoulders in patients with polymyalgia rheumatica (PMR) and elderly-onset rheumatoid arthritis with PMR-like onset (pm-EORA) using ultrasound. Methods . We analyzed stored power Doppler (PD) images obtained by the pretreatment examination of 15 PMR patients and 15 pm-EORA patients. A semiquantitative scoring system for evaluating the severity of PD signals adjacent to the anterior aspect of the subscapularis tendon was designed. Results . A four-point scale scoring for the hyperemia on the subscapularis tendon was proposed as follows in brief: 0 = absent or minimal flow, 1 = single vessel dots or short linear-shape signals, 2 = long linear-shape signals or short zone-shape signals, or 3 = long zone-shape signals. This scoring system showed good intra- and interobserver reliability and good correlation to quantitative pixel-counting evaluation. By using it, we demonstrated that inflammation in PMR is dominantly localized in extrasynovial soft tissue as compared with pm-EORA. Conclusions . We proposed a reliable semiquantitative scoring system using ultrasound for the evaluation of extrasynovial soft tissue inflammation of the shoulders in patients with both PMR and pm-EORA. This system is simple to use and can be utilized in future investigations.

  2. Forbidden Structures for Planar Perfect Consecutively Colourable Graphs

    Directory of Open Access Journals (Sweden)

    Borowiecka-Olszewska Marta

    2017-05-01

    Full Text Available A consecutive colouring of a graph is a proper edge colouring with posi- tive integers in which the colours of edges incident with each vertex form an interval of integers. The idea of this colouring was introduced in 1987 by Asratian and Kamalian under the name of interval colouring. Sevast- janov showed that the corresponding decision problem is NP-complete even restricted to the class of bipartite graphs. We focus our attention on the class of consecutively colourable graphs whose all induced subgraphs are consecutively colourable, too. We call elements of this class perfect consecutively colourable to emphasise the conceptual similarity to perfect graphs. Obviously, the class of perfect consecutively colourable graphs is induced hereditary, so it can be characterized by the family of induced forbidden graphs. In this work we give a necessary and sufficient conditions that must be satisfied by the generalized Sevastjanov rosette to be an induced forbid- den graph for the class of perfect consecutively colourable graphs. Along the way, we show the exact values of the deficiency of all generalized Sevastjanov rosettes, which improves the earlier known estimating result. It should be mentioned that the deficiency of a graph measures its closeness to the class of consecutively colourable graphs. We motivate the investigation of graphs considered here by showing their connection to the class of planar perfect consecutively colourable graphs.

  3. Colour constancy in natural images through colour naming and sensor sharpening

    OpenAIRE

    Vázquez Corral, Javier

    2014-01-01

    Advisors: Maria Vanrell, Graham Finlayson. Date and location of PhD thesis defense: 28 February 2011, Universitat Autònoma de Barcelona Colour is derived from three physical properties: incident light, object reflectance and sensor sensitivities. Incident light varies under natural conditions; hence, recovering scene illuminant is an important issue in computational colour. One way to deal with this problem under calibrated conditions is by following three steps, 1) building a narrow-band ...

  4. Colour: code, mode, modality

    DEFF Research Database (Denmark)

    van Leeuwen, Theo

    2014-01-01

    This article uses a social semiotic approach to discuss the influence of film, video and digital technologies on the way colour is used in audiovisual media......This article uses a social semiotic approach to discuss the influence of film, video and digital technologies on the way colour is used in audiovisual media...

  5. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  6. Colour discrimination and categorisation in Williams syndrome.

    Science.gov (United States)

    Farran, Emily K; Cranwell, Matthew B; Alvarez, James; Franklin, Anna

    2013-10-01

    Individuals with Williams syndrome (WS) present with impaired functioning of the dorsal visual stream relative to the ventral visual stream. As such, little attention has been given to ventral stream functions in WS. We investigated colour processing, a predominantly ventral stream function, for the first time in nineteen individuals with Williams syndrome. Colour discrimination was assessed using the Farnsworth-Munsell 100 hue test. Colour categorisation was assessed using a match-to-sample test and a colour naming task. A visual search task was also included as a measure of sensitivity to the size of perceptual colour difference. Results showed that individuals with WS have reduced colour discrimination relative to typically developing participants matched for chronological age; performance was commensurate with a typically developing group matched for non-verbal ability. In contrast, categorisation was typical in WS, although there was some evidence that sensitivity to the size of perceptual colour differences was reduced in this group. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...

  8. Balancing selection maintains cryptic colour morphs.

    Science.gov (United States)

    Wellenreuther, Maren

    2017-11-01

    Animals display incredibly diverse colour patterns, a testament to evolution's endless innovation in shaping life. In many species, the interplay between males and females in the pursuit of mates has driven the evolution of a myriad of colour forms, from the flashy peacock tail feathers to the tiniest colour markings in damselflies. In others, colour provides crypsis by allowing to blend into the background and to escape the eyes of predators. While the obvious benefits of this dazzling diversity for reproduction and survival seem straightforward, its maintenance is not. Theory predicts that genetic drift and various forms of selection reduce variation over time, making the persistence of colour variants over generations a puzzle. In this issue of Molecular Ecology, Lindtke et al. () study the cryptic colour morphs of Timema cristinae walking sticks to shed light on the genetic architecture and mechanisms that allow colour polymorphism maintenance over long timescales. By combining genome-wide data with phenotyping information from natural populations, they were able to map the green and melanistic colour to one genomic region with highly reduced effective recombination rate between two main chromosomal variants, consistent with an inversion polymorphism. These two main chromosomal variants showed geographically widespread heterozygote excess, and genomic signatures consistent with long-term balancing selection. A younger chromosomal variant was detected for the third morph, the green-striped colour morphs, in the same genomic regions as the melanistic and the green-unstriped morphs. Together, these results suggest that the genetic architecture of cryptic T. cristinae morphs is caused by nonrecombining genomic blocks that have been maintained over extended time periods by balancing selection making this study one of the few available empirical examples documenting that balancing selection of various forms may play an important role in maintaining adaptive genetic

  9. Colour Vision Deficiency and Physics Teaching

    Science.gov (United States)

    Maule, Louise; Featonby, David

    2016-01-01

    1 in 12 males suffer from some form of colour vision deficiency (CVD) which in the present colour dominated world of education presentation can be a severe disadvantage. Although aware of "colourblindness" most teachers make little or no adjustment for these pupils for whom tasks may be more difficult. This article examines colour vision…

  10. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  11. The colour wheels of art, perception, science and physiology

    Science.gov (United States)

    Harkness, Nick

    2006-06-01

    Colour is not the domain of any one discipline be it art, philosophy, psychology or science. Each discipline has its own colour wheel and this presentation examines the origins and philosophies behind the colour circles of Art, Perception, Science and Physiology (after image) with reference to Aristotle, Robert Boyle, Leonardo da Vinci, Goethe, Ewald Hering and Albert Munsell. The paper analyses and discusses the differences between the four colour wheels using the Natural Colour System® notation as the reference for hue (the position of colours within each of the colour wheels). Examination of the colour wheels shows the dominance of blue in the wheels of art, science and physiology particularly at the expense of green. This paper does not consider the three-dimensionality of colour space its goal was to review the hue of a colour with regard to its position on the respective colour wheels.

  12. Radiation-reversible material carriers of different colour

    International Nuclear Information System (INIS)

    Hofmann, G.

    1976-01-01

    A suggestion is made instead of using coloured material carriers - the cones and cylindrical tubes in spinning mills and weaving mills are given as example - to use such ones which change colour with irradiation and keep this colour until a new radiation impulse causes a new colour which differs well from the first one. (No data on material or type of radiation are given.) (UWI) [de

  13. Normal D-dimer ved dyb venøs trombose i en overekstremitet hos to patienter med pacemaker

    DEFF Research Database (Denmark)

    Byrne, Christina; Abdulla, Jawdat; Christensen, Jan Kim

    2015-01-01

    D-dimer, DVT was verified by colour Doppler ultrasound in both cases. The guidelines of American College of Chest Physicians recommend initial evaluation using colour Doppler ultrasound as front-line examination. Accordingly, we suggest a similar revision of Danish guidelines incorporating upper...

  14. Colour-specific differences in attentional deployment for equiluminant pop-out colours: evidence from lateralised potentials.

    Science.gov (United States)

    Pomerleau, Vincent Jetté; Fortier-Gauthier, Ulysse; Corriveau, Isabelle; Dell'Acqua, Roberto; Jolicœur, Pierre

    2014-03-01

    We investigated how target colour affected behavioural and electrophysiological results in a visual search task. Perceptual and attentional mechanisms were tracked using the N2pc component of the event-related potential and other lateralised components. Four colours (red, green, blue, or yellow) were calibrated for each participant for luminance through heterochromatic flicker photometry and equated to the luminance of grey distracters. Each visual display contained 10 circles, 1 colored and 9 grey, each of which contained an oriented line segment. The task required deploying attention to the colored circle, which was either in the left or right visual hemifield. Three lateralised ERP components relative to the side of the lateral coloured circle were examined: a posterior contralateral positivity (Ppc) prior to N2pc, the N2pc, reflecting the deployment of visual spatial attention, and a temporal and contralateral positivity (Ptc) following N2pc. Red or blue stimuli, as compared to green or yellow, had an earlier N2pc. Both the Ppc and Ptc had higher amplitudes to red stimuli, suggesting particular selectivity for red. The results suggest that attention may be deployed to red and blue more quickly than to other colours and suggests special caution when designing ERP experiments involving stimuli in different colours, even when all colours are equiluminant. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. The theory and phenomenology of coloured quark models

    CERN Document Server

    Close, F E

    1975-01-01

    A general introduction to coloured quark models is given and their phenomenology is described with particular reference to the new particles. It is shown that there are essentially three types of colour models with colour excitation when the colour group is SU(3)- Han-Nambu, Greenberg and a model which has the same charges as that of Tati and which can be thought of as the Gell-Mann colour scheme with excitation of the colour degrees of freedom. Particular attention is paid to the four problems of colour models for psi phenomenology-the radiative decays, the G parity conservation, the lack of deep inelastic threshold phenomena and the apparent discovery of dileptons at SPEAR. (40 refs).

  16. The theory and phenomenology of coloured quark models

    International Nuclear Information System (INIS)

    Close, F.E.

    1975-01-01

    A general introduction to coloured quark models is given and their phenomenology is described with particular reference to the new particles. It is shown that there are essentially three types of colour models with colour excitation when the colour group is SU(3) - Han-Nambu, Greenberg and a model which has the same charges as that of Tati and which can be thought of as the Gell-Mann colour scheme with excitation of the colour degrees of freedom. Particular attention is paid to the four problems of colour models for PSI phenomenology - the radiative decays, the G parity conservation, the lack of deep inelastic threshold phenomena and the apparent discovery of dileptons at SPEAR. (author)

  17. Energy losses (gains) of massive coloured particles in stochastic colour medium

    International Nuclear Information System (INIS)

    Leonidov, A.; Rossijskaya Akademiya Nauk, Moscow

    1995-01-01

    The propagation of massive coloured particles in stochastic background chromoelectric field is studied using the semiclassical equations of motion. Depending on the nature of the stochastic background we obtain the formulae for the energy losses of heavy coloured projectile in nonperturbative hadronic medium and for the energy gains in the stochastic field present, e.g., in the turbulent plasma. The result appears to be significantly dependent on the form of the correlation function of stochastic external field. (orig.)

  18. Comparison of radiation-induced colouration images, thermoluminescence, and after-glow colour images with aluminium impurity distribution in Japanese twin quartzes

    International Nuclear Information System (INIS)

    Hashimoto, Tetsuo; Ojima, Tetsu; Takahashi, Eishi; Konishi, Masayoshi; Kanemaki, Motoko.

    1995-01-01

    After-glow colour images (AGCI) and thermoluminescence (TL) from Japanese twin quartz slices have been successfully photographed by means of a commercially available negative colour film after the irradiation of X-rays. After-glow colour images (AGCI) offered very interesting distinction of colour images; the core part showed the colour changed from sky blue with zonal orange to blue with increasing absorbed doses, whereas the outer parts maintained orange AG colour giving clear boundary. On the other hand, the radiation-induced colour (blackish or brownish) center image (CCI) appeared at the core portion, while thermoluminescence colour images (TLCI) also consisted of two portions distinguishable into stripe and zonal bluish core and faint TL emission part in outer ones. These luminescence colour images, probably reflecting the formation mechanism of Japanese twin quartzes, are evidently correlated with the concentration patterns of aluminium impurity obtained by an EPMA (electron probe microanalyzer) method. From these radiation-induced images, it was assumed that the conditions of crystal formation should be greatly different between the core and the outer parts; the outer parts were secondarily started to grow from hydrothermal solution with higher Al-concentration after the initial formation of single core. (author)

  19. Shell Colour Polymorphism in Bulla ampulla

    DEFF Research Database (Denmark)

    Cedhagen, Tomas

    1999-01-01

    Colour patterns of Bulla ampulla shells collected from Africa eastward to Pacific Islands were studied. 1\\vo common colour morphs were found. The typical morph is commonest. It is closely and finely mottled or all over with pinkish-gray on a creamy or flesh~tinted ground, with darker clouds......, irregular, V-shaped, or as longitudinal bands. The colouration of the other common morph is more uniform. It is lacking the darker clouds or bands and the colour is more greyish. The entire shell surface is densely mottled all over with small brown spots on a grey or beige background. Both morphs seem...

  20. Whorfian effects on colour memory are not reliable.

    Science.gov (United States)

    Wright, Oliver; Davies, Ian R L; Franklin, Anna

    2015-01-01

    The Whorfian hypothesis suggests that differences between languages cause differences in cognitive processes. Support for this idea comes from studies that find that patterns of colour memory errors made by speakers of different languages align with differences in colour lexicons. The current study provides a large-scale investigation of the relationship between colour language and colour memory, adopting a cross-linguistic and developmental approach. Colour memory on a delayed matching-to-sample (XAB) task was investigated in 2 language groups with differing colour lexicons, for 3 developmental stages and 2 regions of colour space. Analyses used a Bayesian technique to provide simultaneous assessment of two competing hypotheses (H1-Whorfian effect present, H0-Whorfian effect absent). Results of the analyses consistently favoured H0. The findings suggest that Whorfian effects on colour memory are not reliable and that the importance of such effects should not be overestimated.

  1. Scalable, full-colour and controllable chromotropic plasmonic printing

    OpenAIRE

    Xue, Jiancai; Zhou, Zhang-Kai; Wei, Zhiqiang; Su, Rongbin; Lai, Juan; Li, Juntao; Li, Chao; Zhang, Tengwei; Wang, Xue-Hua

    2015-01-01

    Plasmonic colour printing has drawn wide attention as a promising candidate for the next-generation colour-printing technology. However, an efficient approach to realize full colour and scalable fabrication is still lacking, which prevents plasmonic colour printing from practical applications. Here we present a scalable and full-colour plasmonic printing approach by combining conjugate twin-phase modulation with a plasmonic broadband absorber. More importantly, our approach also demonstrates ...

  2. Characteristics of Skeletal Musculature of Pheasants Hatched from Eggs of Different Eggshell Colour

    Directory of Open Access Journals (Sweden)

    Dragan Zikic

    2016-05-01

    Full Text Available The aim of this paper was to examine morphodinamics of development of skeletal musculature of pheasants hatched from eggs of different eggshell colour. Four groups of pheasant eggs (dark brown, light brown, brown/green and blue/green were incubated. Samples of skeletal musculature of leg and breast were taken during the embryonic and neonatal period of development. From taken samples histological preparations were made. In pheasants hatched from blue/green eggs the smaller diameter of leg and breast muscle cells and the higher volume density of connective tissue in leg and breast muscles were recorded. It was concluded that pheasants hatched from blue/green eggs had the weakest development of skeletal musculature, which can be related to structural differences of eggshell of various colour.

  3. Transforming 3D Coloured Pixels into Musical Instrument Notes for Vision Substitution Applications

    Directory of Open Access Journals (Sweden)

    Deville Benoît

    2007-01-01

    Full Text Available The goal of the See ColOr project is to achieve a noninvasive mobility aid for blind users that will use the auditory pathway to represent in real-time frontal image scenes. We present and discuss here two image processing methods that were experimented in this work: image simplification by means of segmentation, and guiding the focus of attention through the computation of visual saliency. A mean shift segmentation technique gave the best results, but for real-time constraints we simply implemented an image quantification method based on the HSL colour system. More particularly, we have developed two prototypes which transform HSL coloured pixels into spatialised classical instrument sounds lasting for 300 ms. Hue is sonified by the timbre of a musical instrument, saturation is one of four possible notes, and luminosity is represented by bass when luminosity is rather dark and singing voice when it is relatively bright. The first prototype is devoted to static images on the computer screen, while the second has been built up on a stereoscopic camera which estimates depth by triangulation. In the audio encoding, distance to objects was quantified into four duration levels. Six participants with their eyes covered by a dark tissue were trained to associate colours with musical instruments and then asked to determine on several pictures, objects with specific shapes and colours. In order to simplify the protocol of experiments, we used a tactile tablet, which took the place of the camera. Overall, colour was helpful for the interpretation of image scenes. Moreover, preliminary results with the second prototype consisting in the recognition of coloured balloons were very encouraging. Image processing techniques such as saliency could accelerate in the future the interpretation of sonified image scenes.

  4. Transforming 3D Coloured Pixels into Musical Instrument Notes for Vision Substitution Applications

    Directory of Open Access Journals (Sweden)

    Guido Bologna

    2007-08-01

    Full Text Available The goal of the See ColOr project is to achieve a noninvasive mobility aid for blind users that will use the auditory pathway to represent in real-time frontal image scenes. We present and discuss here two image processing methods that were experimented in this work: image simplification by means of segmentation, and guiding the focus of attention through the computation of visual saliency. A mean shift segmentation technique gave the best results, but for real-time constraints we simply implemented an image quantification method based on the HSL colour system. More particularly, we have developed two prototypes which transform HSL coloured pixels into spatialised classical instrument sounds lasting for 300 ms. Hue is sonified by the timbre of a musical instrument, saturation is one of four possible notes, and luminosity is represented by bass when luminosity is rather dark and singing voice when it is relatively bright. The first prototype is devoted to static images on the computer screen, while the second has been built up on a stereoscopic camera which estimates depth by triangulation. In the audio encoding, distance to objects was quantified into four duration levels. Six participants with their eyes covered by a dark tissue were trained to associate colours with musical instruments and then asked to determine on several pictures, objects with specific shapes and colours. In order to simplify the protocol of experiments, we used a tactile tablet, which took the place of the camera. Overall, colour was helpful for the interpretation of image scenes. Moreover, preliminary results with the second prototype consisting in the recognition of coloured balloons were very encouraging. Image processing techniques such as saliency could accelerate in the future the interpretation of sonified image scenes.

  5. Field-portable pixel super-resolution colour microscope.

    Directory of Open Access Journals (Sweden)

    Alon Greenbaum

    Full Text Available Based on partially-coherent digital in-line holography, we report a field-portable microscope that can render lensfree colour images over a wide field-of-view of e.g., >20 mm(2. This computational holographic microscope weighs less than 145 grams with dimensions smaller than 17×6×5 cm, making it especially suitable for field settings and point-of-care use. In this lensfree imaging design, we merged a colorization algorithm with a source shifting based multi-height pixel super-resolution technique to mitigate 'rainbow' like colour artefacts that are typical in holographic imaging. This image processing scheme is based on transforming the colour components of an RGB image into YUV colour space, which separates colour information from brightness component of an image. The resolution of our super-resolution colour microscope was characterized using a USAF test chart to confirm sub-micron spatial resolution, even for reconstructions that employ multi-height phase recovery to handle dense and connected objects. To further demonstrate the performance of this colour microscope Papanicolaou (Pap smears were also successfully imaged. This field-portable and wide-field computational colour microscope could be useful for tele-medicine applications in resource poor settings.

  6. Colour vision experimental studies in teaching of optometry

    Science.gov (United States)

    Ozolinsh, Maris; Ikaunieks, Gatis; Fomins, Sergejs

    2005-10-01

    Following aspects related to human colour vision are included in experimental lessons for optometry students of University of Latvia. Characteristics of coloured stimuli (emitting and reflective), determination their coordinates in different colour spaces. Objective characteristics of transmitting of colour stimuli through the optical system of eye together with various types of appliances (lenses, prisms, Fresnel prisms). Psychophysical determination of mono- and polychromatic stimuli perception taking into account physiology of eye, retinal colour photoreceptor topography and spectral sensitivity, spatial and temporal characteristics of retinal receptive fields. Ergonomics of visual perception, influence of illumination and glare effects, testing of colour vision deficiencies.

  7. IRIS COLOUR CLASSIFICATION SCALES – THEN AND NOW

    Science.gov (United States)

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual’s eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale. PMID:27373112

  8. Colour reconnection in WW events

    CERN Document Server

    D'Hondt, J

    2003-01-01

    Preliminary results are presented for a measurement of the kappa parameter used in the JETSET SK-I model of colour reconnection in W /sup +/W/sup -/ to qq'qq' events at LEP2. An update on the investigation of colour reconnection effects in hadronic decays of W pairs, using the particle flow in DELPHI is presented. A second method is based on the observation that two different m/sub W/ estimators have different sensitivity to the parametrised colour reconnection effect. Hence the difference between them is an observable with information content about kappa. (6 refs).

  9. Rockpool gobies change colour for camouflage.

    Directory of Open Access Journals (Sweden)

    Martin Stevens

    Full Text Available Camouflage is found in a wide range of species living in numerous habitat types, offering protection from visually guided predators. This includes many species from the intertidal zone, which must cope with background types diverse in appearance and with multiple predator groups foraging at high and low tide. Many animals are capable of either relatively slow (hours, days, weeks or rapid (seconds and minutes colour change in order to better resemble the background against which they are found, but most work has been restricted to a few species or taxa. It is often suggested that many small intertidal fish are capable of colour change for camouflage, yet little experimental work has addressed this. Here, we test rock gobies (Gobius paganellus for colour change abilities, and whether they can tune their appearance to match the background. In two experiments, we place gobies on backgrounds of different brightness (black or white, and of different colours (red and blue and use digital image analysis and modelling of predator (avian vision to quantify colour and luminance (perceived lightness changes and camouflage. We find that gobies are capable of rapid colour change (occurring within one minute, and that they can change their luminance on lighter or darker backgrounds. When presented on backgrounds of different colours, gobies also change their colour (hue and saturation while keeping luminance the same. These changes lead to predicted improvements in camouflage match to the background. Our study shows that small rockpool fish are capable of rapid visual change for concealment, and that this may be an important mechanism in many species to avoid predation, especially in complex heterogeneous environments.

  10. Rockpool gobies change colour for camouflage.

    Science.gov (United States)

    Stevens, Martin; Lown, Alice E; Denton, Alexander M

    2014-01-01

    Camouflage is found in a wide range of species living in numerous habitat types, offering protection from visually guided predators. This includes many species from the intertidal zone, which must cope with background types diverse in appearance and with multiple predator groups foraging at high and low tide. Many animals are capable of either relatively slow (hours, days, weeks) or rapid (seconds and minutes) colour change in order to better resemble the background against which they are found, but most work has been restricted to a few species or taxa. It is often suggested that many small intertidal fish are capable of colour change for camouflage, yet little experimental work has addressed this. Here, we test rock gobies (Gobius paganellus) for colour change abilities, and whether they can tune their appearance to match the background. In two experiments, we place gobies on backgrounds of different brightness (black or white), and of different colours (red and blue) and use digital image analysis and modelling of predator (avian) vision to quantify colour and luminance (perceived lightness) changes and camouflage. We find that gobies are capable of rapid colour change (occurring within one minute), and that they can change their luminance on lighter or darker backgrounds. When presented on backgrounds of different colours, gobies also change their colour (hue and saturation) while keeping luminance the same. These changes lead to predicted improvements in camouflage match to the background. Our study shows that small rockpool fish are capable of rapid visual change for concealment, and that this may be an important mechanism in many species to avoid predation, especially in complex heterogeneous environments.

  11. The role of colour in implicit and explicit memory performance.

    Science.gov (United States)

    Vernon, David; Lloyd-Jones, Toby J

    2003-07-01

    We present two experiments that examine the effects of colour transformation between study and test (from black and white to colour and vice versa, of from incorrectly coloured to correctly coloured and vice versa) on implicit and explicit measures of memory for diagnostically coloured natural objects (e.g., yellow banana). For naming and coloured-object decision (i.e., deciding whether an object is correctly coloured), there were shorter response times to correctly coloured-objects than to black-and-white and incorrectly coloured-objects. Repetition priming was equivalent for the different stimulus types. Colour transformation did not influence priming of picture naming, but for coloured-object decision priming was evident only for objects remaining the same from study to test. This was the case for both naming and coloured-object decision as study tasks. When participants were asked to consciously recognize objects that they had named or made coloured-object decisions to previously, whilst ignoring their colour, colour transformation reduced recognition efficiency. We discuss these results in terms of the flexibility of object representations that mediate priming and recognition.

  12. Salience of Primary and Secondary Colours in Infancy

    Science.gov (United States)

    Franklin, Anna; Pitchford, Nicola; Hart, Lynsey; Davies, Ian R. L.; Clausse, Samantha; Jennings, Siobhan

    2008-01-01

    Primary colour terms ("black", "white", "red", "green", "yellow", and "blue") are more fundamental in colour language than secondary colour terms ("pink", "purple", "orange", "brown", and "grey"). Here, we assess whether this distinction exists in the absence of language, by investigating whether primary colours attract and sustain preverbal…

  13. Technical aspects in understanding effects of gamma irradiation on flower colour changes in Dendrobium Sonia

    International Nuclear Information System (INIS)

    Sakinah Ariffin; Azhar Mohammad; Ratnam, W.

    2012-01-01

    Colour is one of the most important traits in orchids and has created great interest in breeding programmes. Gamma irradiation is an alternative way for generation of somaclonal variation for new flower colours. Phenotypic changes are usually observed during screening and selection of mutants. Understanding of targeted gene expression level and evaluation of the changes facilitate in the development of functional markers for selection of desired flower colour mutants. Four Dendrobium orchid sequences (NCBI accessions: AM490639, AY41319, FM209429 and DQ462460) were selected to design gene specific primers based on information for chalcone synthase (CHS) from NCBI database. Quantitative real-time PCR (qPCR) was used to understand flower colour expression quantitatively derived from the CHS gene activities in different flower tissues (petal and sepal) from control Dendrobium Sonia (red purple), mutant DS 35-1/M (purple pink) and mutant DS 35-WhiteA. It was found that expression of CHS gene was highest in sepals of white flowers and lowest in both sepals and petals of purple pink flowers. Genomic DNA was amplified and PCR products were sequenced, aligned and compared. Sequence variations of CHS partial gene in Dendrobium Sonia mutants with different flower colour showed that two protein positions have been changed as compared to the control. These non-synonymous mutations may have contributed to the colour alterations in the white and purple pink mutants. This paper describes important procedures to quantify gene expression such as RNA isolation (quantity and quality), cDNA synthesis and primer design steps for CHS genes. (author)

  14. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    Science.gov (United States)

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation. PMID:25505135

  15. Pseudoisochromatic test plate colour representation dependence on printing technology

    International Nuclear Information System (INIS)

    Luse, K; Ozolinsh, M; Fomins, S

    2012-01-01

    The aim of the study is to determine best printing technology for creation of colour vision deficiency tests. Valid tests for protanopia and deuteranopia were created from perceived colour matching experiments from printed colour samples by colour deficient individuals. Calibrated EpsonStylus Pro 7800 printer for ink prints and Noritsu HD 3701 digital printer for photographic prints were used. Multispectral imagery (by tunable liquid crystal filters system CRI Nuance Vis 07) data analysis show that in case of ink prints, the measured pixel colour coordinate dispersion (in the CIExy colour diagram) of similar colour arrays is smaller than in case of photographic printing. The print quality in terms of colour coordinate dispersion for printing methods used is much higher than in case of commercially available colour vision deficiency tests.

  16. Spectral Doppler findings in a rare case of acute compartment syndrome following leg burn

    Directory of Open Access Journals (Sweden)

    Omer A. Mahmoud

    2018-04-01

    Full Text Available Acute compartment syndrome (ACS is an orthopedic emergency condition, which is rarely attributed to burns. It occurs when pressure in an enclosed space rises to a point where it reduces blood flow and impairs tissue perfusion. Its consequences often lead to ischemia and possible necrosis within that space. Until now, the use of Doppler assessment to explore different types of compartment syndrome has yielded contradictory findings. Here, we present a significant increase of blood flow velocity in the arteries proximal to the burned area. Thus, the combination of Duplex ultrasound results with clinical findings will help vascular surgeons to make immediate decision to perform fasciotomy. Keywords: Compartment syndrome, Spectral Doppler

  17. Relationship between natural tooth shade and skin colour.

    Science.gov (United States)

    Nourbakhsh, M; Mousavinejad, N; Adli, A R; Harati, M

    2013-06-01

    The purpose of this study was to assess the correlation of skin colour and tooth shade. One hundred and twenty six individuals aging between 18 to 25 years participated in this study. Colour of the maxillary central incisors was examined by VITA easy shade. Tooth shades were assigned to four ordinal values. Nivea Beauty Protect Foundation shade sample was used as a guide to assess facial skin colour Shin colours were also assigned to four ordinal values. Spearman test revealed that there was a significant relationship between tooth shade and skin colour Total co-relation factor was 51.6% (p men (p <0 .01). The highest tooth shade prevalence belonged to the second group and the highest skin colour prevalence was also in the second skin colour group.

  18. Utility of Tissue Doppler Imaging in the Echocardiographic Evaluation of Left and Right Ventricular Function in Dogs with Myxomatous Mitral Valve Disease with or without Pulmonary Hypertension.

    Science.gov (United States)

    Baron Toaldo, M; Poser, H; Menciotti, G; Battaia, S; Contiero, B; Cipone, M; Diana, A; Mazzotta, E; Guglielmini, C

    2016-05-01

    In human medicine, right ventricular (RV) functional parameters represent a tool for risk stratification in patients with congestive heart failure caused by left heart disease. Little is known about RV alterations in dogs with left-sided cardiac disorders. To assess RV and left ventricular (LV) function in dogs with myxomatous mitral valve disease (MMVD) with or without pulmonary hypertension (PH). One-hundred and fourteen dogs: 28 healthy controls and 86 dogs with MMVD at different stages. Prospective observational study. Animals were classified as healthy or having MMVD at different stages of severity and according to presence or absence of PH. Twenty-eight morphological, echo-Doppler, and tissue Doppler imaging (TDI) variables were measured and comparison among groups and correlations between LV and RV parameters were studied. No differences were found among groups regarding RV echo-Doppler and TDI variables. Sixteen significant correlations were found between RV TDI and left heart echocardiographic variables. Dogs with PH had significantly higher transmitral E wave peak velocity and higher E/e' ratio of septal (sMV) and lateral (pMV) mitral annulus. These 2 variables were found to predict presence of PH with a sensitivity of 84 and 72%, and a specificity of 71 and 80% at cut-off values of 10 and 9.33 for sMV E/e' and pMV E/e', respectively. No association between variables of RV function and different MMVD stage and severity of PH could be detected. Some relationships were found between echocardiographic variables of right and left ventricular function. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  19. Looking at anything that is green when hearing "frog": how object surface colour and stored object colour knowledge influence language-mediated overt attention.

    Science.gov (United States)

    Huettig, Falk; Altmann, Gerry T M

    2011-01-01

    Three eye-tracking experiments investigated the influence of stored colour knowledge, perceived surface colour, and conceptual category of visual objects on language-mediated overt attention. Participants heard spoken target words whose concepts are associated with a diagnostic colour (e.g., "spinach"; spinach is typically green) while their eye movements were monitored to (a) objects associated with a diagnostic colour but presented in black and white (e.g., a black-and-white line drawing of a frog), (b) objects associated with a diagnostic colour but presented in an appropriate but atypical colour (e.g., a colour photograph of a yellow frog), and (c) objects not associated with a diagnostic colour but presented in the diagnostic colour of the target concept (e.g., a green blouse; blouses are not typically green). We observed that colour-mediated shifts in overt attention are primarily due to the perceived surface attributes of the visual objects rather than stored knowledge about the typical colour of the object. In addition our data reveal that conceptual category information is the primary determinant of overt attention if both conceptual category and surface colour competitors are copresent in the visual environment.

  20. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  1. An Urban Colour Space in the Context of Culture

    Directory of Open Access Journals (Sweden)

    Olga Zheleznyak

    2015-08-01

    Full Text Available A colour space is seen as an actual discourse when discussing problems of formation and inhabitation of the modern city environment. The key aspect of such understanding is an activity-cultural interpretation of the urban environment colouristics proposed by the author, which allows building of an integral sphere of colour existence. This model of working with colour includes basic components and structures a colour space, while matching up all the elements (basic paradigms that provide proper functioning and development of the colour space; mechanisms of formation of colour paradigms; processes of formation and transformation of cultural norms and stereotypes; the culture of colour as a holistic unit that penetrates the variety of colour space forms, as well as the reality of colour establishment in the framework of human culture; the urban colouristics as a material and virtual, artificial and natural, organized and spontaneously appearing colour reality together with professional and conventional visions of it, etc..

  2. Several ways of breaking the colour symmetry

    International Nuclear Information System (INIS)

    Krolikowski, W.

    1975-01-01

    We discuss some cases of colour-symmetry breaking and its implications for quark binding by one-gluon-exchange forces. We pay special attention to the case, where colour-isospin and colour-hypercharge subsymmetries are preserved. Then, the ω-PHI-like mixing of colour-nonet components 0 and 8 leads to a Zweig-type approximate selection rule for decays of PHI-like meson = antiqsub(B)qsub(B)(qsub(B) is the '' blue'' quark) into ordinary mesons (and photons). (author)

  3. Dimensionality of the Consumer Perceived Value of Product Colour

    OpenAIRE

    Kiehelä, Hanna

    2014-01-01

    Consumers’ product assessments are largely based on colour, and a product’s colour can increase consumer satisfaction, awareness and loyalty. However, existing colour research is fragmented and calls for theoretically-enhanced understandings of the role of colour in consumer product perception. The existing colour research mainly focuses on consumers’ immediate reactions when exposed to colours although studies show that consumers evaluate products differently in purchase and in use. There...

  4. Colour Consideration for Waiting areas in hospitals

    Science.gov (United States)

    Zraati, Parisa

    2012-08-01

    Colour is one the most important factors in the nature that can have some affects on human behaviour. Many years ago, it was proven that using colour in public place can have some affect on the users. Depend of the darkness and lightness; it can be vary from positive to negative. The research will mainly focus on the colour and psychological influences and physical factors. The statement of problem in this research is what is impact of colour usually applied to waiting area? The overall aim of the study is to explore the visual environment of hospitals and to manage the colour psychological effect of the hospital users in the waiting area by creating a comfortable, pleasant and cozy environment for users while spend their time in waiting areas. The analysisconcentrate on satisfaction and their interesting regarding applied colour in two private hospital waiting area in Malaysia.

  5. Exploring the benefit of synaesthetic colours: Testing for “pop-out” in individuals with grapheme–colour synaesthesia

    Science.gov (United States)

    Rich, Anina N.; Karstoft, Karen-Inge

    2013-01-01

    In grapheme–colour synaesthesia, letters, numbers, and words elicit involuntary colour experiences. Recently, there has been much emphasis on individual differences and possible subcategories of synaesthetes with different underlying mechanisms. In particular, there are claims that for some, synaesthesia occurs prior to attention and awareness of the inducing stimulus. We first characterized our sample using two versions of the “Synaesthetic Congruency Task” to distinguish “projector” and “associator” synaesthetes who may differ in the extent to which their synaesthesia depends on attention and awareness. We then used a novel modification of the “Embedded Figures Task” that included a set-size manipulation to look for evidence of preattentive “pop-out” from synaesthetic colours, at both a group and an individual level. We replicate an advantage for synaesthetes over nonsynaesthetic controls on the Embedded Figures Task in accuracy, but find no support for pop-out of synaesthetic colours. We conclude that grapheme–colour synaesthetes are fundamentally similar in their visual processing to the general population, with the source of their unusual conscious colour experiences occurring late in the cognitive hierarchy. PMID:23768150

  6. Colour and lighting in hospital design

    Science.gov (United States)

    Dalke, Hilary; Little, Jenny; Niemann, Elga; Camgoz, Nilgun; Steadman, Guillaume; Hill, Sarah; Stott, Laura

    2006-06-01

    Little information or guidance has been available to assist the development of a hospital's visual environment. A report on lighting and colour design schemes, accessible to non professionals with responsibility for refurbishment strategies, was required by NHS Estates. Firstly, 20 hospitals were audited to establish a picture of current practice and to identify key issues where colour design could broadly enhance the environment for patients, staff and visitors. Critical areas were outlined in this report, where colour design can be utilised and applied, for the benefit of all users, from ambience to essential legal requirements such as colour contrast for the visually impaired. Provision of staff relaxation rooms that are different in terms of colour and lux levels from immediate work spaces, or thoughtfully designed areas for patients awaiting intensive treatment, have been shown to have some beneficial effects on a sense of well being. Colour and design have not been established as a definite cure for sickness and ill health, but certainly monotony and poor conditions in premises that have not been refurbished with any care, have had a detrimental affect on recovery rates and staff morale. The realisation that a well balanced and attractive environment is of major importance to patients' health is, in no way new; Florence Nightingale observed that 'a variety of form and brilliance of colour in the objects presented to patients are an actual means of recovery'.

  7. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  8. ANALYSES OF ROCK SURFACE COLOUR CHANGES DUE TO WEATHERING

    OpenAIRE

    GOKAY, Mehmet Kemal

    2018-01-01

    Description parameters of rock masses and minerals include their colours as well. Colours appear in daylight for surfaced rock masses are changing slightly due to weathering layers which have been covering its surface gradually. Healthy human eyes can manage to differentiate visible light spectrum to identify colours of substances including rock masses. Then visible blackish colours of magnetite minerals, reddish colours of Terra- Rosa soils, greenish colours of weathered copper ore, pure whi...

  9. ANALYSES OF ROCK SURFACE COLOUR CHANGES DUE TO WEATHERING

    OpenAIRE

    GÖKAY, Mehmet Kemal

    2018-01-01

    Description parameters of rock masses and minerals include their colours as well. Colours appear in daylight for surfaced rock masses are changing slightly due to weathering layers which have been covering its surface gradually. Healthy human eyes can manage to differentiate visible spectrum to identify the colours of substance including rock masses. Then visible blackish colours of magnetite minerals, reddish colours of Terra- Rosa soils, greenish colours of weathered copper ore, pure white ...

  10. Plants and colour: Flowers and pollination

    Science.gov (United States)

    Miller, Renee; Owens, Simon J.; Rørslett, Bjørn

    2011-03-01

    While there is a range of colours found in plants the predominant colour is green. Pigments in plants have several roles e.g. photosynthesis and signalling. If colour is to be used as a signal then it must stand out from green. However, one should be aware that there are also coloured compounds where we have not yet fully investigated the role of colour in their functions—they may have roles in, for example, defence or heat exchange. In this paper, we will describe the basic chemistry of the major pigments found in plants and especially floral pigments. We will then discuss their locations in parts of the flower (such as sepals, petals, pollen and nectar), the cells in which they are found and their sub-cellular locations. Floral pigments have a large role to play in pollination of flowers by animals. They can and are modified in many ways during the development of flowers in nature, for example, at emergence and post-pollination. There are a range of biochemical mechanisms of colour change both within flowers and in isolated pigments. Some of the factors influencing colour are temperature, co-pigments, pH, metals, sugars, anthocyanin stacking and cell shape. There is a renewed interest in analysing floral pigments and how they are modified partly because of advances in recombinant DNA technologies, but also because of pollinators and their significance to biodiversity and for evolutionary studies. There is continued strong interest from the horticultural industry for the introduction of new colours e.g. the blue rose and for the exploitation of natural dyes. Funding in this area may impact future research in a potentially beneficial way but it must not deflect us from science-based conservation.

  11. Ultrasound assessed thickness of burn scars in association with laser Doppler imaging determined depth of burns in paediatric patients.

    Science.gov (United States)

    Wang, Xue-Qing; Mill, Julie; Kravchuk, Olena; Kimble, Roy M

    2010-12-01

    This study describes the ultrasound assessment of burn scars in paediatric patients and the association of these scar thickness with laser Doppler imaging (LDI) determined burn depth. A total of 60 ultrasound scar assessments were conducted on 33 scars from 21 paediatric burn patients at 3, 6 and 9 months after-burn. The mean of peak scar thickness was 0.39±0.032 cm, with the thickest at 6 months (0.40±0.036 cm). There were 17 scald burn scars (0.34±0.045 cm), 4 contact burn scars (0.61±0.092 cm), and 10 flame burn scars (0.42±0.058 cm). Each group of scars followed normal distributions. Twenty-three scars had original burns successfully scanned by LDI and various depths of burns were presented by different colours according to blood perfusion units (PU), with dark blue burns, with the thinnest scars for green coloured burns and the thickest for dark blue coloured burns. Within light blue burns, grafted burns healed with significantly thinner scars than non-grafted burns. This study indicates that LDI can be used for predicting the risk of hypertrophic scarring and for guiding burn care. To our knowledge, this is the first study to correlate the thickness of burns scars by ultrasound scan with burn depth determined by LDI. Copyright © 2010 Elsevier Ltd and ISBI. All rights reserved.

  12. Producing colour pictures from SCAN

    International Nuclear Information System (INIS)

    Robichaud, K.

    1982-01-01

    The computer code SCAN.TSK has been written for use on the Interdata 7/32 minicomputer which will convert the pictures produced by the SCAN program into colour pictures on a colour graphics VDU. These colour pictures are a more powerful aid to detecting errors in the MONK input data than the normal lineprinter pictures. This report is intended as a user manual for using the program on the Interdata 7/32, and describes the method used to produce the pictures and gives examples of JCL, input data and of the pictures that can be produced. (U.K.)

  13. Synchronization analysis of coloured delayed networks under ...

    Indian Academy of Sciences (India)

    This paper investigates synchronization of coloured delayed networks under decentralized pinning intermittent control. To begin with, the time delays are taken into account in the coloured networks. In addition, we propose a decentralized pinning intermittent control for coloured delayed networks, which is different from that ...

  14. Flare colours and luminosities

    International Nuclear Information System (INIS)

    Cristaldi, S.; Rodono, M.

    1975-01-01

    Flare colours determined from simultaneous UBV observations made at Catania Observatory and from sequential UBV observations made at McDonald Observatory are presented. They fit fairly well with the theoretical colours computed according to the Gurzadian's (1970) non-thermal model. Only part of the observed flare colours are consistent with the solar type models by Gershberg (1967) and Kunkel (1970). From a B-band patrol of UV Cet-type stars carried out from 1967 to 1972, some quantitative estimates of flare frequencies and luminosities and their average contributions to the stellar radiation are given. The corresponding parameters for the Sun, which were estimated from 'white light' flare activity, are also given for comparison. The Sun and V 1216 Sgr can be regarded as low-activity flare stars of the type found by Kunkel (1973). (Auth.)

  15. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  16. Fundamentals of colour awareness: a literature review

    Directory of Open Access Journals (Sweden)

    A. Rubin

    2005-12-01

    Full Text Available A description of some of the basic or funda-mental aspects of the colour sensory mechanism will be provided here, based on modern ideas and literature, with reference specifically to the likely origins and evolution of colour vision.  The mo-lecular basis for colour awareness and the human colour pathway will also be considered in some detail. This paper intends to provide the theoreti-cal and philosophical basis for further papers that will introduce a modern and original computer- based  method  for  more  comprehensive  colour vision  assessment.    This  new  approach,  to  be fully described in later manuscripts, may contrib-ute towards improvements in understanding and knowledge of human colour perception and its measurement, still perhaps a relatively under-ex-plored or neglected field of study within optom-etry and ophthalmology.

  17. Role of combined use of classical induced mutation breeding and biotechnology in development of new flower colour/form in ornamentals

    International Nuclear Information System (INIS)

    Datta, SK.

    2001-01-01

    In floriculture trade there is always demand and necessity of new and novel ornamental varieties. Flower colour is one of the most important component of novelties. Induced somatic mutation techniques by using ionizing radiations and other mutagens have successfully produced quite a large number of new promising varieties (50 Nos.) in different ornamental (Bougainvillea, Chrysanthemum, Hibiscus, Rose, Tuberose, Lantana depressa etc.) plants by bringing about genetic changes at Floriculture Section, National Botanical Research Institute, India. For inducing novelties in flower colour of different plants the technique of selection of proper type/state of plant material for experiment, suitable dose, detection of mutation at right stage of development, isolation and multiplication of chimeric tissue have been standardised. The capability of the technique is well understood from significant number of new varieties developed via direct mutation breeding in already adapted, modern genotypes and enriched the germplasm. The mutations in flower lour/shape were detected as chimera in M1v1, M1v2, M1v3 generations. The mutation frequency varied with the cultivar and exposure of gamma rays. The main bottleneck of mutation breeding is that the mutation appears as chimera. When the entire branch is mutated, mutants can be isolated through conventional propagation techniques while small sectorial mutation in the floret cannot be isolated using existing conventional techniques. Therefore, many new flower colour/shape mutants are lost due to the lack of a suitable propagation technique. By applying biotechnological technique on the same mutagen treated gamma rays population a novel tissue culture technique hasbeen standardised to regenerate plants directly from such mutated sectors (ray florets) of Chrysanthemum. A number of somatic flower colour/shape mutants have been developed in Chrysanthemum by using this in vitro technique. Combination of classical mutation breeding and

  18. ON f-EDGE COVER-COLOURING OF SIMPLE GRAPHS

    Institute of Scientific and Technical Information of China (English)

    Song Huimin; Liu Guizhen

    2005-01-01

    An f-edge cover-colouring of a graph G = (V, E) is an assignment of colours to the edges of G such that every colour appears at each vertex υ∈ V at least f(υ) times.The maximum number of colours needed to f-edge cover colour G is called the f-edge cover chromatic index of G, denoted by χfc(G). This paper gives that min[d(ν)-1/f(ν)] ≤χfc(G) ≤min[d(υ)/f(υ)].

  19. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  20. Long-range correlations from colour confinement

    International Nuclear Information System (INIS)

    Jurkiewicz, J.; Zenczykowski, P.

    1979-01-01

    A class of independent parton emission models is generalized by the introduction of the colour degrees of freedom. In the proposed models colour confinement extorts strong long-range forward-backward correlations, the rise of one-particle inclusive distribution and the KNO scaling. It leads to the analytically calculable definite asymptotic predictions for the D/ ratio which depends only on the choice of the colour group. Multiplicity distribution develops a remarkably long tail. (author)

  1. String Formation Beyond Leading Colour

    CERN Document Server

    Christiansen, Jesper R.

    2015-08-03

    We present a new model for the hadronisation of multi-parton systems, in which colour correlations beyond leading $N_C$ are allowed to influence the formation of confining potentials (strings). The multiplet structure of $SU(3)$ is combined with a minimisation of the string potential energy, to decide between which partons strings should form, allowing also for "baryonic" configurations (e.g., two colours can combine coherently to form an anticolour). In $e^+e^-$collisions, modifications to the leading-colour picture are small, suppressed by both colour and kinematics factors. But in $pp$ collisions, multi-parton interactions increase the number of possible subleading connections, counteracting their naive $1/N_C^2$ suppression. Moreover, those that reduce the overall string lengths are kinematically favoured. The model, which we have implemented in the PYTHIA 8 generator, is capable of reaching agreement not only with the important $\\left(n_\\mathrm{charged})$ distribution but also with measured rates (and ra...

  2. TISSUE DOPPLER IMAGING OF LONGITUDINAL MOVEMENT OF A FIBROUS RING OF MITRAL VALVE DURING ISOVOLUMIC PERIODS IN LEFT VENTRICULAR HYPERTROPHY

    Directory of Open Access Journals (Sweden)

    B. Amarjagal

    2007-01-01

    Full Text Available Aim. To study change of rate and duration indicators of longitudinal movement of a fibrous ring of mitral valve (MFR during isovolumic contraction (IVC and relaxation (IVR in hypertensive patients with various degree of a left ventricular hypertrophy (LVH.Material and methods. 80 hypertensive patients with moderate LVH (n=40 and severe LVH (n=40 are examined. The control group was presented by 30 healthy volunteers. Transthoracic echocardiography and Tissue Doppler imaging has been performed with ultrasonic tomograph “HDI 5000” (Philips.Results. Increase in LVH (Smm and Е/Еmm associates with reduction in systolic velocity of movement of medial MFR (Smm. There is direct relation with duration of IVC-negative and IVR-positive components and myocardium mass index. Maximal velocity of IVC-positive component increases and maximal velocity of IVR-negative component decreases when LVH is growing.Conclusion. Velocities curves of IVC and IVR were bi-phase both in healthy persons and in hypertensive patients with LVH. Velocity and duration of positive and negative components of IVC and IVR depended on LVH degree.

  3. TISSUE DOPPLER IMAGING OF LONGITUDINAL MOVEMENT OF A FIBROUS RING OF MITRAL VALVE DURING ISOVOLUMIC PERIODS IN LEFT VENTRICULAR HYPERTROPHY

    Directory of Open Access Journals (Sweden)

    B. Amarjagal

    2015-12-01

    Full Text Available Aim. To study change of rate and duration indicators of longitudinal movement of a fibrous ring of mitral valve (MFR during isovolumic contraction (IVC and relaxation (IVR in hypertensive patients with various degree of a left ventricular hypertrophy (LVH.Material and methods. 80 hypertensive patients with moderate LVH (n=40 and severe LVH (n=40 are examined. The control group was presented by 30 healthy volunteers. Transthoracic echocardiography and Tissue Doppler imaging has been performed with ultrasonic tomograph “HDI 5000” (Philips.Results. Increase in LVH (Smm and Е/Еmm associates with reduction in systolic velocity of movement of medial MFR (Smm. There is direct relation with duration of IVC-negative and IVR-positive components and myocardium mass index. Maximal velocity of IVC-positive component increases and maximal velocity of IVR-negative component decreases when LVH is growing.Conclusion. Velocities curves of IVC and IVR were bi-phase both in healthy persons and in hypertensive patients with LVH. Velocity and duration of positive and negative components of IVC and IVR depended on LVH degree.

  4. Counting with Colours? Effect of Colours on the Numerical Abilities of House Crows (Corvus splendens) and Common Myna (Acridotheres tristis)

    OpenAIRE

    Rahman, Nor Amira Abdul; Ali, Zalila; Zuharah, Wan Fatma; Fadzly, Nik

    2016-01-01

    We conducted several aviary experiments to investigate the influence of colours in quantity judgments of two species of birds; house crow (Corvus splendens) and common myna (Acridotheres tristis). Different quantity (in seven different food proportions) of mealworms were presented nonsequentially to all birds using artificially coloured red mealworms, for experiment 1, and using artificially coloured green mealworms, for experiment 2. Both red and green coloured mealworms have no significant ...

  5. Application of Modern Colour Measurement Dervices in Coloration Industries

    Institute of Scientific and Technical Information of China (English)

    CHUNG Y.S.; XIN John H.; SIN K.M.

    2002-01-01

    In colour measurement ralated industry, reflectance spectrophotometer is the one of the popular measuring machine for measutring colour and quality control. Colour communications is frequently confusing. This is because the colour appearance is subject to the influence of at least three different phenomena: the light source, the object and the visual system. The variation in either the radiant quantity or the spectral distribution of the source can alter the observed colour. Because of this reason,the objective quantitative tool, colour measurement equipment and communication method; become more important in evaluating of the colour. In fact, based on the advanced in computer system and electronic device,the colour measurement becomes more and more accuracy, especiany in spectrophotometer measurement.In this paper, we will focus on the review of modern spectrophotometers in coloration industries.

  6. Biological Components of Colour Preference in Infancy

    Science.gov (United States)

    Franklin, Anna; Bevis, Laura; Ling, Yazhu; Hurlbert, Anya

    2010-01-01

    Adult colour preference has been summarized quantitatively in terms of weights on the two fundamental neural processes that underlie early colour encoding: the S-(L+M) ("blue-yellow") and L-M ("red-green") cone-opponent contrast channels ( Ling, Hurlbert & Robinson, 2006; Hurlbert & Ling, 2007). Here, we investigate whether colour preference in…

  7. Colour Management as a Precondition of Quality

    Directory of Open Access Journals (Sweden)

    Stefan Brues

    2004-12-01

    Full Text Available Colour management technology has reached a high level of maturity. Only ten years after it first appeared on the market, ICC colour profiles have become indispensable in modern premedia. It can be said without exaggeration that colour management has revolutionised digital proof printing. A whole range of newcomers in the print industry supplier community offer an intelligent combination of a PostScript RIP with integral colour management functions. The quality of these low-priced proofing systems has now reached such a high level that even discerning customers accept such digital proofs as contract proofs. Modular proofing solutions are regularly to be found among the leaders in the digital proofer tests.Working with colour profiles and profiled workflows is still a major problem area. It is no mere chance that notably digital proofing is the field in which users work with colour profiles in virtually all systems, since applications here are locally limited.An important step for the widespread use of colour management technology is the now very extensive implementation of ICC mechanisms in application programs such as Adobe Photoshop. Version 7 is regarded as a model of well thought-out ICC-based colour management implementation. As Microsoft has neglected the ICC standard in recent years, Adobe has created its own colour management interface, called ACE. Based on the ICC standard, it is regarded by many experts as a reference implementation. Adobe products, which are so important for the graphic arts industry, now contain a standard colour management platform across all supported operating systems. Incompatibilities at system level can now be virtually ruled out, at least across the Adobe product line, including the important interfaces with PostScript and PDF.Modern prepress technology is set to move ever further away from exclusive print production for standardised offset print. Multiple use of production data is still at an early stage

  8. The Pathophysiology of Decompression Sickness and the Effects of Doppler Detectable Bubbles.

    Science.gov (United States)

    1980-12-18

    workers (Harvey, 1951a and 1951b) and Blinks, Twitty and Whiteker (1951) show that muscular activity was a 23 ~I. predisposing factor to the formation of...Hills, 1966), the mechanism of action is somewhat specific (neural distension ); but for those theories utilizing circulation and/or intravascular...highly perfused non- muscular tissue, such as kidney, forms a gas phase following decompression, Doppler perivascular cuff probes were surgically placed on

  9. Fundamentals of colour awareness: a literature review

    OpenAIRE

    A. Rubin

    2005-01-01

    A description of some of the basic or funda-mental aspects of the colour sensory mechanism will be provided here, based on modern ideas and literature, with reference specifically to the likely origins and evolution of colour vision.  The mo-lecular basis for colour awareness and the human colour pathway will also be considered in some detail. This paper intends to provide the theoreti-cal and philosophical basis for further papers that will introduce a modern and original computer- based  met...

  10. Influence of drug colour on perceived drug effects and efficacy.

    Science.gov (United States)

    Tao, Da; Wang, Tieyan; Wang, Tieshan; Qu, Xingda

    2018-02-01

    A drug's physical characteristics, such as colour, could be factors influencing its therapeutic effects. It is not well understood whether people's expectations on drug effects and efficacy are affected by colour, especially among Chinese population. This study was conducted to examine people's expectations on drug effects and efficacy on the basis of drug colour, and to reveal possible gender differences in colour-related drug expectations. Participants (n = 224) were asked to classify seven single-coloured and six two-coloured capsules into one of four categories of drug effects, and to indicate the strength of drug efficacy. It is found that all the coloured capsules yielded non-chance distributions in classifications of drug effects, with six single-coloured and four two-coloured capsules associated with specific drug effects. Colour also conveyed differential strengths of drug efficacy in general and in relation to specific drug effects. There were gender differences in drug expectations for some colours and colour combinations. Practitioner Summary: Drug colour was found to have impacts on perceived drug effects and efficacy. The findings from the present study can be used by ergonomics practitioners to design appropriate drug colours in support of drug differentiation, therapeutic effects and medication adherence.

  11. Kac's ring: The case of four colours

    Indian Academy of Sciences (India)

    2017-03-15

    Mar 15, 2017 ... generalize the discussion to more than two colours. Although the generalization seems nearly trivial, it will be shown that there appear interesting, unanticipated technical difficulties or surprises when we consider four colours. In this work, we consider the Kac's ring with balls of four colours, calling them red ...

  12. The evolutionary history of colour polymorphism in Ischnura damselflies.

    Science.gov (United States)

    Sánchez-Guillén, Rosa A; Cordero-Rivera, Adolfo; Rivas-Torres, Anais; Wellenreuther, Maren; Bybee, Seth; Hansson, Bengt; Velasquez-Vélez, María I; Realpe, Emilio; Chávez-Ríos, Jesús R; Villalobos, Fabricio; Dumont, Henri

    2018-05-10

    A major challenge in evolutionary biology consists of understanding how genetic and phenotypic variation is created and maintained. In the present study, we investigated the origin(s) and evolutionary patterns of the female-limited colour polymorphism in ischnuran damselflies. These consist of the presence of one to three colour morphs: one androchrome morph with a colouration that is similar to the male, and two gynochrome morphs (infuscans and aurantiaca) with female-specific colouration. We (i) documented the colour and mating system of 44 of the 75 taxa within the genus Ischnura, (ii) reconstructed the evolutionary history of colour and mating system to identify the ancestral state, (iii) evaluated the stability of the colour morph status over time, and (iv) tested for a correlation between colour and mating system. We found that the ances tral female colour of Ischnura was monomorphic and aurantiaca and that colour morph status changed over time; characterised by many gains and losses across the species tree. Our results further showed that colour polymorphism is significantly more frequent among polyandric species, whereas monandric species tend to be monomorphic. Research on some Ischnura species has shown that colour morphs have evolved to reduce male mating harassment, and our finding that the same phenotypic morphs have evolved multiple times (convergent evolution) suggests that several species in this genus might be experiencing similar selective pressures. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Study on Tei index of right ventricular by tissue doppler imaging and the observation point selection

    International Nuclear Information System (INIS)

    Luo Yinli; Wu Ji; Guo Shenglan; Zhang Di; Li Zhixian

    2009-01-01

    Objective: To explore the right ventricular (RV) Tei index in patients with pulmonary hypertension (PH) by tissue Doppler imaging (TDI), and to explore more accurate observation point to obtain Tei index of right ventricular. Methods: Assessment of RV Tei index values was performed in 95 patients with PH and 32 normal subjects. The 95 patients were grouped into 3 groups according to the severity of PH. Tei index values were obtained by TDI measurement from three observation points, the anterior tricuspid and septal tricuspid attachment points in the apical 4-chamber view and the posterior tricuspid attachment point in parasternal right heart 2-chamber review. Results: (1) RV Tel index values were measured at the three points of PH was higher than the normal significantly (P<0.05). (2) RV Tei index values of the three PH groups at he anterior tricuspid attachment had significant difference each other (P<0.05). RV Tei index values of low-grade and medium-grade PH groups at septal tricuspid and posterior tricuspid had no significant difference, but that of high-grade PH group were higher than the low-grade and medium-grade PH group. Conclusion: RV Tei index value was significantly increased in PH patients. The Tei index value measured by TDI at anterior tricuspid attachment point in apical 4-chamber view was better than that at septal tricuspid attachment point in the apical 4-chamber view and posterior' attachment of parasternal right heart 2-chamber. (authors)

  14. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  15. Phenomenology of colour exotic fermions

    International Nuclear Information System (INIS)

    Luest, D.

    1986-01-01

    The authors discuss the phenomenological consequences of a dynamical scenario according to which the electroweak symmetry breaking and generation of fermion masses is due to fermions that transform under high colour representations. Particular emphasis is given to the predictions for rare processes and to the spectrum of high colour boundstates. (Auth.)

  16. Behavioural evidence for colour vision in an elasmobranch.

    Science.gov (United States)

    Van-Eyk, Sarah M; Siebeck, Ulrike E; Champ, Connor M; Marshall, Justin; Hart, Nathan S

    2011-12-15

    Little is known about the sensory abilities of elasmobranchs (sharks, skates and rays) compared with other fishes. Despite their role as apex predators in most marine and some freshwater habitats, interspecific variations in visual function are especially poorly studied. Of particular interest is whether they possess colour vision and, if so, the role(s) that colour may play in elasmobranch visual ecology. The recent discovery of three spectrally distinct cone types in three different species of ray suggests that at least some elasmobranchs have the potential for functional trichromatic colour vision. However, in order to confirm that these species possess colour vision, behavioural experiments are required. Here, we present evidence for the presence of colour vision in the giant shovelnose ray (Glaucostegus typus) through the use of a series of behavioural experiments based on visual discrimination tasks. Our results show that these rays are capable of discriminating coloured reward stimuli from other coloured (unrewarded) distracter stimuli of variable brightness with a success rate significantly different from chance. This study represents the first behavioural evidence for colour vision in any elasmobranch, using a paradigm that incorporates extensive controls for relative stimulus brightness. The ability to discriminate colours may have a strong selective advantage for animals living in an aquatic ecosystem, such as rays, as a means of filtering out surface-wave-induced flicker.

  17. The "Human Colour" Crayon: Investigating the Attitudes and Perceptions of Learners regarding Race and Skin Colour

    Directory of Open Access Journals (Sweden)

    Neeske Alexander

    2017-07-01

    Full Text Available Some coloured and black learners in South Africa use a light orange or pink crayon to represent themselves in art. Many learners name this colour “human colour” or “skin colour”. This is troublesome, because it could reflect exclusionary ways of representing race in images and language. This case study, conducted with two schools in the Western Cape, investigated Grade 3 learners’ attitudes and perceptions regarding race and skin colour through art processes and discussion. The aim was to promote critical engagement with race in Foundation Phase educational contexts. Suggestions include changing the language used to describe skin colour, just recognition and representation of races in educational resources and the promotion of critical citizenship education. This research indicates the need to create practical curriculum guidelines to discuss race issues in the South African classroom.

  18. Special Section on Coloured Petri Nets

    DEFF Research Database (Denmark)

    1998-01-01

    Special section on coloured Petri nets, their basic concepts, analysis methods, tool support and industrial applications.......Special section on coloured Petri nets, their basic concepts, analysis methods, tool support and industrial applications....

  19. Genetics and evolution of colour patterns in reptiles.

    Science.gov (United States)

    Olsson, Mats; Stuart-Fox, Devi; Ballen, Cissy

    2013-01-01

    The study of coloration in the polyphyletic reptilians has flourished in the last two decades, in particular with respect to the underlying genetics of colour traits, the function of colours in social interactions, and ongoing selection on these traits in the wild. The taxonomic bias, however, is profound: at this level of resolution almost all available information is for diurnal lizards. Therefore, we focus on case studies, for which there are as complete causal sequences of colour evolution as possible, from phenotypic expression of variation in colour, to ongoing selection in the wild. For work prior to 1992 and for a broader coverage of reptilian coloration we refer the readers to Cooper and Greenburg's (Biology of the Reptilia, 1992) review. There are seven major conclusions we would like to emphasise: (a) visual systems in diurnal lizards are broadly conserved but among the wider range of reptiles in general, there is functionally important variation in the number and type of photoreceptors, spectral tuning of photopigments and optical properties of the eye; (b) coloration in reptiles is a function of complex interactions between structural and pigmentary components, with implications for both proximate control and condition dependence of colour expression; (c) studies of colour-variable species have enabled estimates of heritability of colour and colour patterns, which often show a simple Mendelian pattern of inheritance; (d) colour-polymorphic lizard species sometimes, but not always, show striking differences in genetically encoded reproductive tactics and provide useful models for studying the evolution and maintenance of polymorphism; (e) both male and female colours are sometimes, but not always, a significant component of socio-sexual signalling, often based on multiple traits; (f) evidence for effects of hormones and condition on colour expression, and trade-offs with immunocompetence and parasite load, is variable; (g) lizards show fading of colours

  20. Modern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge.

    Science.gov (United States)

    Grudzińska, Ewa; Modrzejewska, Monika

    2018-01-01

    Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.

  1. Reliability of laser Doppler, near-infrared spectroscopy and Doppler ultrasound for peripheral blood flow measurements during and after exercise in the heat.

    Science.gov (United States)

    Choo, Hui C; Nosaka, Kazunori; Peiffer, Jeremiah J; Ihsan, Mohammed; Yeo, Chow C; Abbiss, Chris R

    2017-09-01

    This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 ± 0.4°C and 32 ± 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (%CVC BL ). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, %CVC BL , TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r 2  = 0.062) and TOI (r 2  = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.

  2. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  3. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  4. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  5. Complementary Colours for a Physicist

    Science.gov (United States)

    Babic, Vitomir; Cepic, Mojca

    2009-01-01

    This paper reports on a simple experiment which enables splitting incident light into two different modes, each having a colour exactly complementary to the other. A brief historical development of colour theories and differences in a physicist's point of view with respect to an artist's one is discussed. An experimental system for producing…

  6. Improper colouring of (random) unit disk graphs

    NARCIS (Netherlands)

    Kang, R.J.; Müller, T.; Sereni, J.S.

    2008-01-01

    For any graph G, the k-improper chromatic number ¿k(G) is the smallest number of colours used in a colouring of G such that each colour class induces a subgraph of maximum degree k. We investigate ¿k for unit disk graphs and random unit disk graphs to generalise results of McDiarmid and Reed

  7. Mixed colour states in QCD confining vacuum

    OpenAIRE

    Buividovich, P. V.; Kuvshinov, V. I.

    2005-01-01

    We show that confinement of spinless heavy quarks in fundamental representation of $SU(N_{c})$ gauge group can be treated as decoherence of pure colour state into a white mixture of states. Decoherence rate is found to be proportional to the tension of QCD string and the distance between colour charges. The purity of colour states is calculated.

  8. Geographical variation in colour of female threespine stickleback (Gasterosteus aculeatus).

    Science.gov (United States)

    French, Connor M; Ingram, Travis; Bolnick, Daniel I

    2018-01-01

    The ecological multifunctionality of colour often results in multiple selective pressures operating on a single trait. Most research on colour evolution focuses on males because they are the most conspicuous sex in most species. This bias can limit inferences about the ecological drivers of colour evolution. For example, little is known about population divergence in colour of female threespine stickleback ( Gasterosteus aculeatus ), which is among the most intensively-studied model vertebrates in evolution, ecology, and behaviour. In contrast, the evolution and ecology of colour in male stickleback has received considerable attention. One aspect of female colouration that is lacking previous research is non-ornamental body colour. Non-ornamental colour can play defensive and social roles, and indicate other aspects of female stickleback ecology. To remedy this knowledge gap, we measured the colour and brightness of one dorsal and one ventral lateral area on female stickleback from nine lake populations on Vancouver Island. We found that lake populations varied in overall colour brightness and dorso-ventral contrast. In addition, we found that female brightness increased with lake size, indicating potential ecological drivers of these colour differences. Our results demonstrate that there is substantial scope for future research on female colour diversification, which has been overlooked because past researchers focused on dramatic male nuptial colours.

  9. Colour print workflow and methods for multilayering of colour and decorative inks using UV inkjet for fine art printing

    Science.gov (United States)

    Parraman, Carinna

    2012-01-01

    In order to increase density of colour and improve ink coverage when printing onto a range of non standard substrates, this paper will present research into multi-layering of colour and the appearance of colour at 'n' levels of ink coverage. Returning to our original investigation of artist's requirements when making inkjet prints, these observations are based on empirical approaches that address the need to present physical data that is more useful and meaningful to the designer. The study has used multi-pass printed colour charts to measure colour and to provide users with an understanding at a soft-preview level to demonstrate the appearance of printed colour on different substrates. Test results relating to the appearance of print on different surfaces, and a series of case studies will be presented using recent research into the capabilities of UV printing technology, which has widened the opportunities for the designer to print onto non-standard materials. It will also present a study into layering of greys and gloss in order to improve the appearance of printed images onto metal.

  10. Limits of colour vision in dim light.

    Science.gov (United States)

    Kelber, Almut; Lind, Olle

    2010-09-01

    Humans and most vertebrates have duplex retinae with multiple cone types for colour vision in bright light, and one single rod type for achromatic vision in dim light. Instead of comparing signals from multiple spectral types of photoreceptors, such species use one highly sensitive receptor type thus improving the signal-to-noise ratio at night. However, the nocturnal hawkmoth Deilephila elpenor, the nocturnal bee Xylocopa tranquebarica and the nocturnal gecko Tarentola chazaliae can discriminate colours at extremely dim light intensities. To be able to do so, they sacrifice spatial and temporal resolution in favour of colour vision. We review what is known about colour vision in dim light, and compare colour vision thresholds with the optical sensitivity of the photoreceptors in selected animal species with lens and compound eyes. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.

  11. Music-colour synaesthesia: Concept, context and qualia.

    Science.gov (United States)

    Curwen, Caroline

    2018-05-01

    This review provides a commentary on coloured-hearing arising on hearing music: music-colour synaesthesia. Although traditionally explained by the hyperconnectivity theory (Ramachandran & Hubbard, 2001a) and the disinhibited feedback theory (Grossenbacher & Lovelace, 2001) as a purely perceptual phenomenon, the review of eight coloured-hearing neuroimaging studies shows that it may not be assumed that these explanations are directly translatable to music-colour synaesthesia. The concept of 'ideaesthesia' (Nikolić, 2009) and the role of conceptual and semantic inducers challenge the likelihood of a single mechanism underlying the cause of synaesthesia and argue for a move away from a purely sensory to sensory explanation. Finally, music-colour synaesthesia forms a challenge for established philosophical theories and the position of synaesthesia is considered within the larger context of musical qualia. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Please pass me the skin coloured crayon!

    DEFF Research Database (Denmark)

    Zimmermann, Martina; Levisen, Carsten; Beck, Thorhalla Gudmundsdottir

    2015-01-01

    worldviews and idealised cognitive models embedded in skin-based colour concepts in contemporary German and Scandi- navian languages. Arguing that colour concepts are linguistic constructs through which speakers have learned to pay attention to their visual worlds, we trace the origin of the skin......This study explores the cultural semantics of colour words in the four urban, European communities of Munich, Berne, Aarhus, and Reykjavik, focussing on hautfarben (German), hutfarb (Bernese Swiss German), hudfarvet (Danish), and húðlitur (Icelandic), all of which can be translated as ‘skin...... coloured’. Unlike in English, where skin coloured has fallen out of use due to its racist semantic profile, these words are still widely present within the four communities. Using evidence from a referential colour naming task and semi-structured interviews, our study seeks to reveal the linguistic...

  13. A familial factor in the development of colour agnosia.

    Science.gov (United States)

    Nijboer, Tanja C W; van Zandvoort, Martine J E; de Haan, Edward H F

    2007-04-09

    An important aspect of research into the link between genes and behaviour concerns the identification of familial determination. There is evidence for familial factors in selective deficits, such as developmental dyslexia and developmental prosopagnosia. Colour agnosia concerns a selective neuropsychological condition in which colour perception is intact, while the identification and naming of colour is disrupted. We recently demonstrated that this deficit can occur as a developmental deficit. Here, we show that there is a familial factor in the development of colour agnosia by reporting the colour processing abilities of the mother and the daughters of a man with developmental colour agnosia.

  14. Physicochemical and physiological basis of dichromatic colour

    Science.gov (United States)

    Kreft, Samo; Kreft, Marko

    2007-11-01

    Out of three perceptual characteristics of the colour of any substance, the hue depends mostly on the spectral properties of a substance, while the brightness and saturation depend also on the concentration of a substance and its thickness. Here, we report that evident change of the hue of the colour (i.e., from green to red) is due to a change in concentration or the thickness of a layer in some exceptional substances such as pumpkin seed oil or an aqueous solution of bromophenol blue. In some regions of Central Europe, salad dressing is made preferably with the pumpkin seed oil, which has a strong characteristic nut-like taste and remarkable properties of the colour: it appears red in a bottle, but green when served as a salad dressing. The colour of the pumpkin seed oil was previously described as brownish yellow, dark green, dark green to red ochre or dark reddish brown to light yellow green. We elucidated the physicochemical and physiological basis of such dichromatism by Beer-Lambert law and by the characteristics of human colour perception. Our concept was corroborated by the outcome of calculations of colour from spectral properties using colour matching functions. We found that dichromatism is observed if the absorption spectrum of any substance has at least two local minima: one wide but shallow and one narrow but deep local minimum.

  15. Colour contribution to children's wayfinding in school environments

    Science.gov (United States)

    Helvacıoǧlu, Elif; Olguntürk, Nilgün

    2011-03-01

    The purpose of this study was to explore the contribution of colour to children's wayfinding ability in school environments and to examine the differences between colours in terms of their remembrance and usability in route learning process. The experiment was conducted with three different sample groups for each of three experiment sets differentiated by their colour arrangement. The participants totalled 100 primary school children aged seven and eight years old. The study was conducted in four phases. In the first phase, the participants were tested for familiarity with the experiment site and also for colour vision deficiencies by using Ishihara's tests for colour-blindness. In the second phase, they were escorted on the experiment route by the tester one by one, from one starting point to one end point and were asked to lead the tester to the end point by the same route. In the third phase, they were asked to describe verbally the route. In the final phase, they were asked to remember the specific colours at their correct locations. It was found that colour has a significant effect on children's wayfinding performances in school environments. However, there were no differences between different colours in terms of their remembrances in route finding tasks. In addition, the correct identifications of specific colours and landmarks were dependent on their specific locations. Contrary to the literature, gender differences were not found to be significant in the accuracy of route learning performances.

  16. Colour relations for Mira and Semiregular (SR) type stars

    International Nuclear Information System (INIS)

    Guney, Yavuz; Yesilyaprak, Cahit

    2016-01-01

    In this study, the period-colour relations, the colour-colour relations and the effective temperature were examined for Semiregular (SR) and Mira type variable stars. SR variables show an obvious period-colour relations, especially in infrared (IR). There are differences between SR and Mira type variable stars with respect to their colour relations. It has been thought that these differencies are caused by their mass loss rates and their effective temperatures. (paper)

  17. Facial Identification in Observers with Colour-Grapheme Synaesthesia

    DEFF Research Database (Denmark)

    Sørensen, Thomas Alrik

    2013-01-01

    Synaesthesia between colours and graphemes is often reported as one of the most common forms cross modal perception [Colizolo et al, 2012, PLoS ONE, 7(6), e39799]. In this particular synesthetic sub-type the perception of a letterform is followed by an additional experience of a colour quality....... Both colour [McKeefry and Zeki, 1997, Brain, 120(12), 2229–2242] and visual word forms [McCandliss et al, 2003, Trends in Cognitive Sciences, 7(7), 293–299] have previously been linked to the fusiform gyrus. By being neighbouring functions speculations of cross wiring between the areas have been...... of Neuroscience, 17(11), 4302–4311], increased colour-word form representations in observers with colour-grapheme synaesthesia may affect facial identification in people with synaesthesia. This study investigates the ability to process facial features for identification in observers with colour...

  18. Floral colour versus phylogeny in structuring subalpine flowering communities.

    Science.gov (United States)

    McEwen, Jamie R; Vamosi, Jana C

    2010-10-07

    The relative number of seeds produced by competing species can influence the community structure; yet, traits that influence seed production, such as pollinator attraction and floral colour, have received little attention in community ecology. Here, we analyse floral colour using reflectance spectra that include near-UV and examined the phylogenetic signal of floral colour. We found that coflowering species within communities tended to be more divergent in floral colour than expected by chance. However, coflowering species were not phylogenetically dispersed, in part due to our finding that floral colour is a labile trait with a weak phylogenetic signal. Furthermore, while we found that locally rare and common species exhibited equivalent floral colour distances from their coflowering neighbours, frequent species (those found in more communities) exhibited higher colour distances from their coflowering neighbours. Our findings support recent studies, which have found that (i) plant lineages exhibit frequent floral colour transitions; and (ii) traits that influence local population dynamics contribute to community structure.

  19. Doppler ultrasound compatible plastic material for use in rigid flow models.

    Science.gov (United States)

    Wong, Emily Y; Thorne, Meghan L; Nikolov, Hristo N; Poepping, Tamie L; Holdsworth, David W

    2008-11-01

    A technique for the rapid but accurate fabrication of multiple flow phantoms with variations in vascular geometry would be desirable in the investigation of carotid atherosclerosis. This study demonstrates the feasibility and efficacy of implementing numerically controlled direct-machining of vascular geometries into Doppler ultrasound (DUS)-compatible plastic for the easy fabrication of DUS flow phantoms. Candidate plastics were tested for longitudinal speed of sound (SoS) and acoustic attenuation at the diagnostic frequency of 5 MHz. Teflon was found to have the most appropriate SoS (1376 +/- 40 m s(-1) compared with 1540 m s(-1) in soft tissue) and thus was selected to construct a carotid bifurcation flow model with moderate eccentric stenosis. The vessel geometry was machined directly into Teflon using a numerically controlled milling technique. Geometric accuracy of the phantom lumen was verified using nondestructive micro-computed tomography. Although Teflon displayed a higher attenuation coefficient than other tested materials, Doppler data acquired in the Teflon flow model indicated that sufficient signal power was delivered throughout the depth of the vessel and provided comparable velocity profiles to that obtained in the tissue-mimicking phantom. Our results indicate that Teflon provides the best combination of machinability and DUS compatibility, making it an appropriate choice for the fabrication of rigid DUS flow models using a direct-machining method.

  20. The cause of 50 million-year-old colour.

    OpenAIRE

    Parker, Andrew R; McKenzie, David R

    2003-01-01

    Multilayer reflectors cause structural, 'metallic' colours in a diversity of animals today, yet are unknown in extinct species. We identify a multilayer reflector, causing structural colour, in a 50-million-year-old beetle from Messel, Germany. It is proposed that the original material of this reflector has been preserved, although this is not a precondition for determining original colours from ancient multilayer reflectors. Therefore, the potential exists to reveal the original colours of o...

  1. Geographical variation in colour of female threespine stickleback (Gasterosteus aculeatus

    Directory of Open Access Journals (Sweden)

    Connor M. French

    2018-05-01

    Full Text Available The ecological multifunctionality of colour often results in multiple selective pressures operating on a single trait. Most research on colour evolution focuses on males because they are the most conspicuous sex in most species. This bias can limit inferences about the ecological drivers of colour evolution. For example, little is known about population divergence in colour of female threespine stickleback (Gasterosteus aculeatus, which is among the most intensively-studied model vertebrates in evolution, ecology, and behaviour. In contrast, the evolution and ecology of colour in male stickleback has received considerable attention. One aspect of female colouration that is lacking previous research is non-ornamental body colour. Non-ornamental colour can play defensive and social roles, and indicate other aspects of female stickleback ecology. To remedy this knowledge gap, we measured the colour and brightness of one dorsal and one ventral lateral area on female stickleback from nine lake populations on Vancouver Island. We found that lake populations varied in overall colour brightness and dorso-ventral contrast. In addition, we found that female brightness increased with lake size, indicating potential ecological drivers of these colour differences. Our results demonstrate that there is substantial scope for future research on female colour diversification, which has been overlooked because past researchers focused on dramatic male nuptial colours.

  2. Assessment of tissue viability by polarization spectroscopy

    Science.gov (United States)

    Nilsson, G.; Anderson, C.; Henricson, J.; Leahy, M.; O'Doherty, J.; Sjöberg, F.

    2008-09-01

    A new and versatile method for tissue viability imaging based on polarization spectroscopy of blood in superficial tissue structures such as the skin is presented in this paper. Linearly polarized light in the visible wavelength region is partly reflected directly by the skin surface and partly diffusely backscattered from the dermal tissue matrix. Most of the directly reflected light preserves its polarization state while the light returning from the deeper tissue layers is depolarized. By the use of a polarization filter positioned in front of a sensitive CCD-array, the light directly reflected from the tissue surface is blocked, while the depolarized light returning from the deeper tissue layers reaches the detector array. By separating the colour planes of the detected image, spectroscopic information about the amount of red blood cells (RBCs) in the microvascular network of the tissue under investigation can be derived. A theory that utilizes the differences in light absorption of RBCs and bloodless tissue in the red and green wavelength region forms the basis of an algorithm for displaying a colour coded map of the RBC distribution in a tissue. Using a fluid model, a linear relationship (cc. = 0.99) between RBC concentration and the output signal was demonstrated within the physiological range 0-4%. In-vivo evaluation using transepidermal application of acetylcholine by the way of iontophoresis displayed the heterogeneity pattern of the vasodilatation produced by the vasoactive agent. Applications of this novel technology are likely to be found in drug and skin care product development as well as in the assessment of skin irritation and tissue repair processes and even ultimately in a clinic case situation.

  3. Asymmetric chiral colour

    International Nuclear Information System (INIS)

    Cuypers, F.

    1990-01-01

    Chiral colour is considered in a general framework where the coupling constants associated with each SU(3) component are allowed to be different. To reproduce QCD at low energy, gluons and axigluons cannot then be maximally mixed. Present data form e + e - colliders contrains the axigluon mass to values between 50 GeV and 375 GeV whilst the mixing angle is bounded by 13deg and 45deg. The lower limit of the axigluon mass is a definite bound at 90% C.L., whereas the upper limit only applies if chiral colour is to explain the anomalously high rates of hadron production at TRISTAN. (orig.)

  4. Colour, vision and ergonomics.

    Science.gov (United States)

    Pinheiro, Cristina; da Silva, Fernando Moreira

    2012-01-01

    This paper is based on a research project - Visual Communication and Inclusive Design-Colour, Legibility and Aged Vision, developed at the Faculty of Architecture of Lisbon. The research has the aim of determining specific design principles to be applied to visual communication design (printed) objects, in order to be easily read and perceived by all. This study target group was composed by a selection of socially active individuals, between 55 and 80 years, and we used cultural events posters as objects of study and observation. The main objective is to overlap the study of areas such as colour, vision, older people's colour vision, ergonomics, chromatic contrasts, typography and legibility. In the end we will produce a manual with guidelines and information to apply scientific knowledge into the communication design projectual practice. Within the normal aging process, visual functions gradually decline; the quality of vision worsens, colour vision and contrast sensitivity are also affected. As people's needs change along with age, design should help people and communities, and improve life quality in the present. Applying principles of visually accessible design and ergonomics, the printed design objects, (or interior spaces, urban environments, products, signage and all kinds of visually information) will be effective, easier on everyone's eyes not only for visually impaired people but also for all of us as we age.

  5. Global skin colour prediction from DNA.

    Science.gov (United States)

    Walsh, Susan; Chaitanya, Lakshmi; Breslin, Krystal; Muralidharan, Charanya; Bronikowska, Agnieszka; Pospiech, Ewelina; Koller, Julia; Kovatsi, Leda; Wollstein, Andreas; Branicki, Wojciech; Liu, Fan; Kayser, Manfred

    2017-07-01

    Human skin colour is highly heritable and externally visible with relevance in medical, forensic, and anthropological genetics. Although eye and hair colour can already be predicted with high accuracies from small sets of carefully selected DNA markers, knowledge about the genetic predictability of skin colour is limited. Here, we investigate the skin colour predictive value of 77 single-nucleotide polymorphisms (SNPs) from 37 genetic loci previously associated with human pigmentation using 2025 individuals from 31 global populations. We identified a minimal set of 36 highly informative skin colour predictive SNPs and developed a statistical prediction model capable of skin colour prediction on a global scale. Average cross-validated prediction accuracies expressed as area under the receiver-operating characteristic curve (AUC) ± standard deviation were 0.97 ± 0.02 for Light, 0.83 ± 0.11 for Dark, and 0.96 ± 0.03 for Dark-Black. When using a 5-category, this resulted in 0.74 ± 0.05 for Very Pale, 0.72 ± 0.03 for Pale, 0.73 ± 0.03 for Intermediate, 0.87±0.1 for Dark, and 0.97 ± 0.03 for Dark-Black. A comparative analysis in 194 independent samples from 17 populations demonstrated that our model outperformed a previously proposed 10-SNP-classifier approach with AUCs rising from 0.79 to 0.82 for White, comparable at the intermediate level of 0.63 and 0.62, respectively, and a large increase from 0.64 to 0.92 for Black. Overall, this study demonstrates that the chosen DNA markers and prediction model, particularly the 5-category level; allow skin colour predictions within and between continental regions for the first time, which will serve as a valuable resource for future applications in forensic and anthropologic genetics.

  6. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  7. Colour learning when foraging for nectar and pollen: bees learn two colours at once.

    Science.gov (United States)

    Muth, Felicity; Papaj, Daniel R; Leonard, Anne S

    2015-09-01

    Bees are model organisms for the study of learning and memory, yet nearly all such research to date has used a single reward, nectar. Many bees collect both nectar (carbohydrates) and pollen (protein) on a single foraging bout, sometimes from different plant species. We tested whether individual bumblebees could learn colour associations with nectar and pollen rewards simultaneously in a foraging scenario where one floral type offered only nectar and the other only pollen. We found that bees readily learned multiple reward-colour associations, and when presented with novel floral targets generalized to colours similar to those trained for each reward type. These results expand the ecological significance of work on bee learning and raise new questions regarding the cognitive ecology of pollination. © 2015 The Author(s).

  8. The cause of 50 million-year-old colour.

    Science.gov (United States)

    Parker, Andrew R; McKenzie, David R

    2003-11-07

    Multilayer reflectors cause structural, 'metallic' colours in a diversity of animals today, yet are unknown in extinct species. We identify a multilayer reflector, causing structural colour, in a 50-million-year-old beetle from Messel, Germany. It is proposed that the original material of this reflector has been preserved, although this is not a precondition for determining original colours from ancient multilayer reflectors. Therefore, the potential exists to reveal the original colours of other (particularly arthropod) extinct species.

  9. KINETICS OF COLOUR CHANGE OF TOMATOES DURING DRYING

    Directory of Open Access Journals (Sweden)

    A. Unadi

    2016-10-01

    Full Text Available Colour is one of the pharameters determining the quality of dried tomatoes. The changes in colour of the skin of tomatoes during drying in an experimental dryer at various temperatures were measured every two hours by using Minolta CR 200 colorimeter and the colours were represented in Hunter-Lab scale. The objective of this research was develop a model for predicting colour changes of tomatoes during drying. The decrease in darkness as represented by dL value varied from 10 to 16%, while decrease in chroma value (dL varied from 20 to 37% of initial values. An empirical logarithmic equation with six constants was derived to fit the data of chroma changes during drying at various temperature and times. The model of colour change of tomatoes can be used for determining the optimum drying temperature to produce acceptable colour of dried tomatoes at reasonable cost.

  10. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  11. Laser Doppler flowmetry evaluation of gingival recovery response after laser treatment

    Science.gov (United States)

    Todea, Carmen; Cânjǎu, Silvana; Dodenciu, Dorin; Miron, Mariana I.; Tudor, Anca; Bǎlǎbuc, Cosmin

    2013-06-01

    This study was performed in order to evaluate in vivo the applicability of Laser Doppler Flowmetry (LDF) in recording the gingival blood flow and to assess the changes of gingival blood flow following gingival reshaping performed with Er:YAG and 980 nm diode lasers. The LDF evaluation was performed on 20 anterior teeth, which underwent reshaping of gingiva, corresponding to 5 female patients (4 anterior teeth/patient), aged between 20 and 35. One part of the mouth was treated with Er:YAG laser (LP, VLP modes, 140 - 250 mJ, 10 - 20 Hz, using cylindrical sapphire tips) and other part with 980 nm diode laser (CW, 4 W, contact mode and saline solution cooling). The gingival blood flow was monitored using a MoorLab laser Doppler equipment (Moor Instruments Ltd., Axminster, UK) with a straight optical probe, MP3b, 10 mm. The data were processed using statistical analysis software SPSS v16.0.1. The investigation showed an evident decrease in perfusion for both areas in comparison with the baseline values 24 hours after treatment. The microvascular blood flow increased significantly after 7 days in both areas but mostly in diode area (pdiode area remained at a high level after 14 days. Both lasers proved efficiency in the surgical treatment of gingival tissue. Moreover, Laser Doppler Flowmetry is adequate for recording changes in gingival blood flow following periodontal surgery.

  12. The existence of panchromatic colourings for uniform hypergraphs

    International Nuclear Information System (INIS)

    Shabanov, Dmitrii A

    2010-01-01

    The well-known extremal problem concerning panchromatic colouring of hypergraphs is investigated. An r-colouring of the set of vertices of a hypergraph is said to be panchromatic if each link of the hypergraph is incident to vertices of all colours. The quantity p(n,r) defined as the minimum number of links in an n-uniform hypergraph which admits no panchromatic r-colourings is studied. New lower and upper bounds for p(n,r) are obtained, which improve earlier results for many of the relations between the parameters n and r. In addition, a sufficient condition for the existence of a panchromatic r-colouring of an n-uniform hypergraph is obtained. Bibliography: 18 items.

  13. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  14. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  15. Selective interference reveals dissociation between memory for location and colour.

    Science.gov (United States)

    Vuontela, V; Rämä, P; Raninen, A; Aronen, H J; Carlson, S

    1999-08-02

    The aim was to study whether there is indication of a dissociation in processing of visuospatial and colour information in working memory in humans. Experimental subjects performed visuospatial and colour n-back tasks with and without visuospatial and colour distractive stimuli presented in the middle of the delay period to specifically affect mnemonic processing of task-related information. In the high memory-load condition, the visuospatial, but not the colour, task was selectively disrupted by visuospatial but not colour distractors. When subvocal rehearsal of the memoranda in the colour task was prevented by articulatory suppression; colour task performance was also selectively disrupted by distractors qualitatively similar to the memoranda. The results support the suggestion that visual working memory for location is processed separate from that for colour.

  16. Annotating Coloured Petri Nets

    DEFF Research Database (Denmark)

    Lindstrøm, Bo; Wells, Lisa Marie

    2002-01-01

    Coloured Petri nets (CP-nets) can be used for several fundamentally different purposes like functional analysis, performance analysis, and visualisation. To be able to use the corresponding tool extensions and libraries it is sometimes necessary to include extra auxiliary information in the CP......-net. An example of such auxiliary information is a counter which is associated with a token to be able to do performance analysis. Modifying colour sets and arc inscriptions in a CP-net to support a specific use may lead to creation of several slightly different CP-nets – only to support the different uses...... of the same basic CP-net. One solution to this problem is that the auxiliary information is not integrated into colour sets and arc inscriptions of a CP-net, but is kept separately. This makes it easy to disable this auxiliary information if a CP-net is to be used for another purpose. This paper proposes...

  17. Use of colour for hand-filled form analysis and recognition

    OpenAIRE

    Sherkat, N; Allen, T; Wong, WS

    2005-01-01

    Colour information in form analysis is currently under utilised. As technology has advanced and computing costs have reduced, the processing of forms in colour has now become practicable. This paper describes a novel colour-based approach to the extraction of filled data from colour form images. Images are first quantised to reduce the colour complexity and data is extracted by examining the colour characteristics of the images. The improved performance of the proposed method has been verifie...

  18. Edge colouring by total labellings

    DEFF Research Database (Denmark)

    Brandt, Stephan; Rautenbach, D.; Stiebitz, M.

    2010-01-01

    We introduce the concept of an edge-colouring total k-labelling. This is a labelling of the vertices and the edges of a graph G with labels 1, 2, ..., k such that the weights of the edges define a proper edge colouring of G. Here the weight of an edge is the sum of its label and the labels of its...

  19. Colouring our view of safety

    International Nuclear Information System (INIS)

    Spare, P.

    2000-01-01

    The public have great difficulty interpreting numerical risk data, and particularly the relative importance of the hazards presented by advanced technologies compared with everyday activities. A form of presentation is proposed, utilizing a decade-based seven colour spectrum. The colours are directly connected to the auditable statistics and provide a qualitative measure of the risk to the non-specialist. (author)

  20. The effects of colour and valence on news evaluation.

    Science.gov (United States)

    Kaspar, Kai; Grümmer, Melanie; Kießler, Antje; Neuß, Celina; Schröter, Franziska

    2017-12-01

    Research across different fields of psychology has reported effects of colour cues on a variety of cognitive processes. Especially, the colour red has been shown to have striking influences. In the context of media reception, however, colour effects have been widely neglected so far. This study made a first step in this direction by investigating the effects of the colour red (compared with blue and grey) on the way news articles are evaluated. Two types of news were framed by a coloured border while the valence of the news content additionally varied. Based on 369 participants who read and evaluated the news articles online, we observed effects for colour cues and news valence in the absence of an interaction effect, indicating that the colour red induced approach motivation. However, only the contrast between red and grey reached statistical significance, indicating that chromatic and achromatic colours may differ in their perceived visual saliency. Overall, these results provide an important complement to previous studies and have practical implications for media researchers and producers. © 2015 International Union of Psychological Science.

  1. Conjunctions of colour, luminance and orientation: the role of colour and luminance contrast on saliency and proximity grouping in texture segregation.

    Science.gov (United States)

    Leonards, U; Singer, W

    2000-01-01

    To examine whether perceptual grouping on the basis of orientation can be performed simultaneously with or only subsequently to grouping according to colour or luminance, we tested whether subjects are able to segregate arrays of texture elements that differ from surrounding elements by conjunctions of either (i) colour and orientation, or (ii) luminance contrast and orientation, or (iii) luminance contrast polarity and orientation. Subjects were able to use conjunctions between luminance and orientation for segregation but not conjunctions between colour or contrast polarity and orientation. Our results suggest that (i) in agreement with earlier findings, there seem to exist no specific conjunction detectors for colour and orientation or contrast polarity and orientation, and (ii) when orientation defined textures are to be distinguished by virtue of differences in luminance, colour, or contrast polarity, luminance provides a much stronger cue than colour or contrast polarity for saliency-based orientation grouping.

  2. Colour and camouflage: design issues in military clothing

    CSIR Research Space (South Africa)

    Baumbach, J

    2012-07-01

    Full Text Available itself. Colour differences can be defined in terms of hue, chromaticness (or chromaticity) and lightness. A person?s hue discrimination (yellow, red, blue and green are different hues of colour) can be determined by the Farnsworth-Munsell 100 Hue... environment are blue. Yellow is the second-lightest colour of the cube in the blue environment. But, when abovementioned blue and yellow squares are isolated from their respective environments (taken out of context), all of them have the same colour...

  3. Relationship between behavioural factors and colour preferences for clothing

    Directory of Open Access Journals (Sweden)

    Milena Fornazarič

    2018-03-01

    Full Text Available The colour of clothing plays an important role in one’s emotional reaction and the selection of clothes, which in turn effects design, the fashion industry and sales. In our behavioural research involving the Slovenian population regarding the selection of colours, we used the results of opportunity sampling, i.e. a web survey using a sample of 204 respondents, who were invited to participate in the research using an email list sampling method. Our aim was determine how demographic and behavioural characteristics affect colour preferences for clothing. Demographic characteristics are not important in terms of the behaviour of different segments of the population, except with regard to gender. Nevertheless, we can use the results of the survey to make a correlation between colour and consumer characteristics. Those who are fond of the colour beige follow fashion trends more closely than the others, while the colour white is associated with those who follow fashion on web and in online shopping. On the contrary, consumers who prefer pink and purple primarily buy clothes in fashion shops. Those who prefer brown and beige enjoy the shopping experience more than others, while lovers of the colour pink are less inclined to buy clothes during sales than others. Consumers who prefer the colour blue are predominant in fitting shops, while those who prefer the colour black do not to buy clothes on Saturdays. Lovers of the colour blue stand out in terms of spending, while people who are fond of the colour white spend the most, although they prefer to buy less expensive clothes. People drawn to the colour grey prefer to buy less expensive jackets, while women who prefer the colour green also buy less expensive jackets. We recommend expanding the scope of the research to include historical determinants, fashion patterns, marketing communication and fashion brands, as well as other, more rational and speculative motives associated with a subject

  4. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  5. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  6. Global skin colour prediction from DNA

    NARCIS (Netherlands)

    S. Walsh (Susan); L.C. Chaitanya (Lakshmi); Breslin, K. (Krystal); Muralidharan, C. (Charanya); Bronikowska, A. (Agnieszka); E. Pośpiech (Ewelina); Koller, J. (Julia); L. Kovatsi (Leda); A. Wollstein (Andreas); W. Branicki (Wojciech); F. Liu; M.H. Kayser (Manfred)

    2017-01-01

    textabstractHuman skin colour is highly heritable and externally visible with relevance in medical, forensic, and anthropological genetics. Although eye and hair colour can already be predicted with high accuracies from small sets of carefully selected DNA markers, knowledge about the genetic

  7. The colour analysis method applied to homogeneous rocks

    Directory of Open Access Journals (Sweden)

    Halász Amadé

    2015-12-01

    Full Text Available Computer-aided colour analysis can facilitate cyclostratigraphic studies. Here we report on a case study involving the development of a digital colour analysis method for examination of the Boda Claystone Formation which is the most suitable in Hungary for the disposal of high-level radioactive waste. Rock type colours are reddish brown or brownish red, or any shade between brown and red. The method presented here could be used to differentiate similar colours and to identify gradual transitions between these; the latter are of great importance in a cyclostratigraphic analysis of the succession. Geophysical well-logging has demonstrated the existence of characteristic cyclic units, as detected by colour and natural gamma. Based on our research, colour, natural gamma and lithology correlate well. For core Ib-4, these features reveal the presence of orderly cycles with thicknesses of roughly 0.64 to 13 metres. Once the core has been scanned, this is a time- and cost-effective method.

  8. [Optic mixing of colours in Seurat's painting].

    Science.gov (United States)

    Cernea, Paul

    2002-01-01

    Georges Seurat is the initiator and master of the divisionism. He founds the neoimpressionism current that tries to reproduce the nature exclusively through coloured vibration. Seurat applies the colours in small touches uniformly distributed on the canvas; the colours merge if they are looked by a certain distance, through optical interference. When the spectator approaches from the picture, the special frequency decreases, the optical merging does not appear and the onlooker looks a lot of coloured spots. When the spectator moves away from the picture, the optical interference appears and the clarity of the image becomes perfectly. This current opened the way of the future's modern painting performed by Cézanne, Renoir, Van Gogh.

  9. String formation beyond leading colour

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, Jesper R. [Department of Astronomy and Theoretical Physics, Lund University,Sölvegatan 14, Lund (Sweden); Theoretical Physics, CERN,CH-1211, Geneva 23 (Switzerland); Skands, Peter Z. [Theoretical Physics, CERN,CH-1211, Geneva 23 (Switzerland); School of Physics and Astronomy, Monash University,VIC-3800 (Australia)

    2015-08-03

    We present a new model for the hadronisation of multi-parton systems, in which colour correlations beyond leading N{sub C} are allowed to influence the formation of confining potentials (strings). The multiplet structure of SU(3) is combined with a minimisation of the string potential energy, to decide between which partons strings should form, allowing also for “baryonic” configurations (e.g., two colours can combine coherently to form an anticolour). In e{sup +}e{sup −}collisions, modifications to the leading-colour picture are small, suppressed by both colour and kinematics factors. But in pp collisions, multi-parton interactions increase the number of possible subleading connections, counteracting their naive 1/N{sub C}{sup 2} suppression. Moreover, those that reduce the overall string lengths are kinematically favoured. The model, which we have implemented in the PYTHIA 8 generator, is capable of reaching agreement not only with the important 〈p{sub ⊥}〉(n{sub charged}) distribution but also with measured rates (and ratios) of kaons and hyperons, in both ee and pp collisions. Nonetheless, the shape of their p{sub ⊥} spectra remains challenging to explain.

  10. Metal free structural colours via disordered nanostructures with nm resolution and full CYMK colour spectrum

    KAUST Repository

    Bonifazi, Marcella

    2017-02-28

    Structural colours represents a research area of great interest, due to a wide field of application ranging from micro-security to biomimetic materials. At present metallic substrate are heavily employed and only a partial spectra of colours can be realised. We propose a novel, metal-free technology that exploits the complex scattering from a disordered three-dimensional dielectric material on a silicon substrate. We reproduce experimentally the full spectrum of CMYK colours, including variations in intensity. Our resolution lies in the nm range, limited only by the electron beam lithography fabrication process. We demonstrate that this technique is extremely robust, suitable for flexible and reusable substrates. Full of these notable proprieties these nano-structures fits perfectly with the requirements of a real-world technology.

  11. Metal free structural colours via disordered nanostructures with nm resolution and full CYMK colour spectrum

    KAUST Repository

    Bonifazi, Marcella; Mazzone, Valerio; Fratalocchi, Andrea

    2017-01-01

    Structural colours represents a research area of great interest, due to a wide field of application ranging from micro-security to biomimetic materials. At present metallic substrate are heavily employed and only a partial spectra of colours can be realised. We propose a novel, metal-free technology that exploits the complex scattering from a disordered three-dimensional dielectric material on a silicon substrate. We reproduce experimentally the full spectrum of CMYK colours, including variations in intensity. Our resolution lies in the nm range, limited only by the electron beam lithography fabrication process. We demonstrate that this technique is extremely robust, suitable for flexible and reusable substrates. Full of these notable proprieties these nano-structures fits perfectly with the requirements of a real-world technology.

  12. Synaesthetic Colour in the Brain: Beyond Colour Areas. A Functional Magnetic Resonance Imaging Study of Synaesthetes and Matched Controls

    OpenAIRE

    van Leeuwen, Tessa M.; Petersson, Karl Magnus; Hagoort, Peter

    2010-01-01

    Background In synaesthesia, sensations in a particular modality cause additional experiences in a second, unstimulated modality (e.g., letters elicit colour). Understanding how synaesthesia is mediated in the brain can help to understand normal processes of perceptual awareness and multisensory integration. In several neuroimaging studies, enhanced brain activity for grapheme-colour synaesthesia has been found in ventral-occipital areas that are also involved in real colour processing. Our q...

  13. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  14. What Colour Is a Shadow?

    Science.gov (United States)

    Hughes, S. W.

    2009-01-01

    What colour is a shadow? Black, grey, or some other colour? This article describes how to use a digital camera to test the hypothesis that a shadow under a clear blue sky has a blue tint. A white sheet of A4 paper was photographed in full sunlight and in shadow under a clear blue sky. The images were analysed using a shareware program called…

  15. The guidance of spatial attention during visual search for colour combinations and colour configurations

    OpenAIRE

    Berggren, Nick; Eimer, Martin

    2016-01-01

    Representations of target-defining features (attentional templates) guide the selection of target objects in visual search. We used behavioural and electrophysiological measures to investigate how such search templates control the allocation of attention in search tasks where targets are defined by the combination of two colours or by a specific spatial configuration of these colours. Target displays were preceded by spatially uninformative cue displays that contained items in one or both tar...

  16. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  17. From spectral information to animal colour vision: experiments and concepts.

    Science.gov (United States)

    Kelber, Almut; Osorio, Daniel

    2010-06-07

    Many animals use the spectral distribution of light to guide behaviour, but whether they have colour vision has been debated for over a century. Our strong subjective experience of colour and the fact that human vision is the paradigm for colour science inevitably raises the question of how we compare with other species. This article outlines four grades of 'colour vision' that can be related to the behavioural uses of spectral information, and perhaps to the underlying mechanisms. In the first, even without an (image-forming) eye, simple organisms can compare photoreceptor signals to locate a desired light environment. At the next grade, chromatic mechanisms along with spatial vision guide innate preferences for objects such as food or mates; this is sometimes described as wavelength-specific behaviour. Here, we compare the capabilities of di- and trichromatic vision, and ask why some animals have more than three spectral types of receptors. Behaviours guided by innate preferences are then distinguished from a grade that allows learning, in part because the ability to learn an arbitrary colour is evidence for a neural representation of colour. The fourth grade concerns colour appearance rather than colour difference: for instance, the distinction between hue and saturation, and colour categorization. These higher-level phenomena are essential to human colour perception but poorly known in animals, and we suggest how they can be studied. Finally, we observe that awareness of colour and colour qualia cannot be easily tested in animals.

  18. Colour terms in the interior design process

    OpenAIRE

    Attiah, DY; Cheung, TLV; Westland, S; Bromilow, D

    2015-01-01

    Colour is a very important topic that interior designers need to consider. Considerable research has been conducted in the area of colour application in interior design; in this study we are concerned with colour terms in interior design, mainly the terms designers use and know about. Fifteen interior designers with varied professional backgrounds, but based in the Middle East (Saudi Arabia, Dubai, Bahrain, Lebanon, Egypt, and Turkey), were interviewed. Previously we reported that fourteen ou...

  19. Multi-jet correlations and colour coherence phenomena

    Directory of Open Access Journals (Sweden)

    Lee Jason S.H.

    2017-01-01

    Full Text Available In multi-jet events, colour coherence was shown to play a important role in the topology of these events. In modern Monte Carlo generators, the colour coherence effect has become an inherent feature, such that the colour coherence effect can no longer be disentangled in a simple manner. This study looks at the multi-jet correlations by comparing Monte Carlo generators in Parton Shower dominant and Matrix Element dominant regions.

  20. Colour discrimination and categorisation in Williams syndrome

    OpenAIRE

    Farran, E. K.; Cranwell, M. B.; Alvarez, J.; Franklin, A.

    2013-01-01

    Individuals with Williams syndrome (WS) present with impaired functioning of the dorsal visual stream relative to the ventral visual stream. As such, little attention has been given to ventral stream functions in WS. We investigated colour processing, a predominantly ventral stream function, for the first time in nineteen individuals with Williams syndrome. Colour discrimination was assessed using the Farnsworth-Munsell 100 hue test. Colour categorisation was assessed using a match-to-sample ...