WorldWideScience

Sample records for color doppler images

  1. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  2. Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer

    International Nuclear Information System (INIS)

    Alexander, Archie A.; Palazzo, Juan P.; Ahmad, Neelofur R.; Liu, J.-B.; Forsberg, Flemming; Marks, John

    1996-01-01

    Purpose: To correlate the endosonographic and color Doppler flow imaging alterations observed in irradiated rectal cancers with the pathologic features of radiation response, and to evaluate the potential impact of altered blood flow on the integrity of the surgical anastamosis. Methods and Materials: Endosonography with color and pulsed wave Doppler was performed on 20 rectal cancer masses before and after high dose preoperative radiation (XRT). Pre- and post-XRT observations included comparing alterations in tumor size, sonographic echotexture, color Doppler flow, and pulsatility indices. Comparisons were made with pathologic findings in the irradiated specimens and with the incidence of anastomotic failure. Results: Compared to pre-XRT observations, irradiated rectal cancers decreased in size and became either mixed in echogenicity with less apparent color Doppler flow (16 of 20) or unchanged in color Doppler flow and echotexture (4 of 20). Those with less flow (16 of 20) were imaged later (mean = 90.2 ± 12.1 days) than those without change in color Doppler flow (mean = 21.7 ± 2.7 days). Pathologically, the group of four without change in color Doppler signal had features of acute inflammation which were not observed in 16 of 20 imaged later. Based on pulsatility index measurements, both high and low resistance vessels were detected and confirmed by immunohistochemical staining, and features of postradiation obliterative vasculitis were observed. Only one primary anastomosis in 14 patients with decreased flow failed. Conclusions: The sonographic and color Doppler flow imaging alterations observed within irradiated rectal cancer correlated with changes of postradiation obliterative vasculitis. The apparent diminished local blood flow within high and low resistance vessels post-XRT did not result in an increased incidence of anastomotic failures

  3. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  4. Diagnostic agreement between panoramic radiographs and color doppler images of carotid atheroma

    Directory of Open Access Journals (Sweden)

    Claudia Maria Romano-Sousa

    2009-02-01

    Full Text Available The aim of this study was to investigate the agreement between diagnoses of calcified atheroma seen on panoramic radiographs and color Doppler images. Our interest stems from the fact that panoramic images can show the presence of atheroma regardless of the level of obstruction detected by color Doppler images. Panoramic and color Doppler images of 16 patients obtained from the archives of the Health Department of the city of Valença, RJ, Brazil, were analyzed in this study. Both sides of each patient were observed on the images, with a total of 32 analyzed cervical regions. The level of agreement between diagnoses was analyzed using the Kappa statistics. There was a high level of agreement, with a Kappa value of 0.78. In conclusion, panoramic radiographs can help detecting calcifications in the cervical region of patients susceptible to vascular diseases predisposing to myocardial infarction and cerebrovascular accidents. If properly trained and informed, dentists can refer their patients to a physician for a cardiovascular evaluation in order to receive proper and timely medical treatment.

  5. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  6. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  7. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  8. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  9. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2009-12-15

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  10. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    International Nuclear Information System (INIS)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee; Kim, Sam Soo

    2009-01-01

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  11. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  12. The Efficacy of Magnetic Resonance Imaging and Color Doppler Ultrasonography in Diagnosis of Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    Behrooz Davachi

    2014-12-01

    Full Text Available Background and aims. Although salivary gland tumors are not very common, early diagnosis and treatment is crucial because of their proximity to vital organs, and therefore, determining the efficacy of new imaging procedures becomes important. This study aimed to evaluate the efficacy of magnetic resonance imaging (MRI and color doppler ultrasonography parameters in the diagnosis and differentiation of benign and malignant salivary gland tumors. Materials and methods. In this cross-sectional study, color doppler ultrasonography and MRI were performed for 22 patients with salivary gland tumor. Demographic data as well as MRI, color doppler ultrasonography, and surgical parameters including tumor site, signal in MRI images, ultrasound echo, tumor border, lymphadenopathy, invasion, perfusion, vascular resistance index (RI, vascular pulse index (PI were analyzed using Chi-square test, Fisher’s exact test, and independent ttest. Results. The mean age of patients was 46.59±13.97 years (8 males and 14 females. Patients with malignant tumors were older (P < 0.01. The most common tumors were pleomorphic adenoma (36.4%, metastasis (36.4%, and mucoepidermoid carcinoma (9%. Nine tumors (40.9% were benign and 13 (59.1% were malignant. The overall accuracy of MRI and color doppler ultrasonography in determining tumor site was 100% and 95%, respectively. No significant difference observed between RI and PI and the diagnosis of tumor. Conclusion. Both MRI and ultrasonography have high accuracy in the localization of tumors. Well-identified border was a sign of benign tumors. Also, invasion to adjacent structures was a predictive factor for malignancy.

  13. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  14. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  15. The Role of Color Doppler Ultrasonography in Characterization of Thyroid Tumors

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Jeon, Pyong; Won, Jong Yoon; Na, Jae Beom; Lee, Hyang Mee; Yoo, Hyung Sik; Lee, Jong Tae; Park, Jeong Soo; Cho, Nam Hoon

    1995-01-01

    To assess the usefulness of color Doppler ultrasonography in the characterization of thyroid tumors, surgically proven 88 nodules in 85 patients were evaluated. Using 10 MHz linear array transducer, gray scale images were initially evaluated. Then, distribution pattern of color signals (marginal, intra-tumoral, mixed) and graded internal vascularity according to morphology of color signal (0:absence of internal signal, 1: spotty, 2: linear,3: branching) were observed on color doppler imaging. Pulsed doppler waves were analyzed with parameters including peak systolic velocity(PSV), resistive index(RI), and pulsatile index(PI). Significantly larger numbers of intra-tumoral type, 20 cases(62.5%), were observed in malignant nodules, whereas mixed forms were predominant in benign group, 37 cases (66%) In graded internal vascularity, malignant nodules tended to have grade 2 or 3 signals, whereas benign nodules tended to have grade 0 or 1 signals. Spectral wave analysis show no significant difference in the value of PSV, RI, and PI between malignancy and benignity group. In conclusion, color Doppler imaging has a potential role in the characterization of thyroid nodules as a supportive method for gray scale diagnosis

  16. Color-flow Doppler imaging in suspected extremity venous thrombosis

    International Nuclear Information System (INIS)

    Foley, W.D.; Middleton, W.D.; Lawson, T.L.; Hinson, G.W.; Puller, D.R.

    1987-01-01

    Color-flow Doppler imaging (CFDI) (Quanatum, 5 and 7.5 MHz, linear array) has been performed on 23 extremities (nine positive for venous thrombosis, 14 negative) with venographic correlation. CFDI criteria evaluated were venous color-flow respiratory variation, augmentation, compressibility, valve competence, and intraluminal echogenic filling defects. Both CFDI and venography were evaluated independently and prospectively. CFDI and venography agreed in all six cases of femoral vein thrombosis and eight of nine cases of popliteal vein thrombosis. CFDI was negative in one instance of recanalized popliteal vein thrombosis. Recanalized femoral vein thrombosis was documented in three patients by CFDI when the vein was nonopacified on conventional venography. CFDI provides a rapid and accurate assessment of the femoral popliteal venous system and can distinguish an occluded from a recanalized thrombus. Initial experience with auxiliary subclavian venous thrombus has produced equally accurate results

  17. Magnetic angioresonance of the carotid artery: correlation with color Doppler ultrasound

    International Nuclear Information System (INIS)

    Cotilla, J.; Miralles, M.; Cairols, M.C.; Dolz, J.L.; Vilanova, J.C.; Capdevila, A.

    1998-01-01

    To determine the value of magnetic angioresonance (MAR) in grading carotid stenosis, comparing it with color Doppler and intraarterial digital subtraction angiography (IADSA). A comparative study using color Doppler and MAR was carried out in 84 patients with coratid lesions. Fifty-two of the patients underwent angiographic study as well. The comparison of MAR versus arteriography in discriminating stenosis of more than 70%, expressed in terms of sensitivity specificity, overall precision and the kappa concordance index, gave values of 87.2, 90.8, 89.4 and 0.78%, respectively. When MAR was compared with color Doppler, the results were 86.8, 85.9, 86.3 and 0.72%, respectively. The results of the comparison between color Doppler and arteriography were 82.2, 86.2, 84.6 and 0.68%, respectively. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability of this imaging technique. (Author) 29 refs

  18. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  19. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  20. Alveolar Echinococcosis of the Liver: Correlative Color Doppler US, CT, and MRI Study

    International Nuclear Information System (INIS)

    Cokun, A.; Oeztuerk, M.; Karahan, O.I.; Erdogan, N.; Ikin, S.; Guelec, M.

    2004-01-01

    Purpose: To determine and compare the imaging features of hepatic alveolar Echinococcosis using color Doppler US, CT, and MRI. Material and Methods: Abdominal CT and MRI with and without contrast agents and color Doppler US were performed on seven patients with hepatic alveolar Echinococcosis. The lesions were evaluated for location, features of echogenicity, intensity and density, calcification, and vascular, hilar, and perihepatic involvement. The diagnosis was confirmed histopathologically in all patients. Results: Six patients had solitary lesions, and one displayed multiple lesions. The lesions were generally seen as heterogeneous and hyper- or hypoechoic when imaged with color Doppler US, hypodense with CT, and hypointense with MRI, in comparison with the liver parenchyma. Calcification, central necrosis, and small peripheral cysts were observed in six, seven, and four patients, respectively. Vascular flow or contrast enhancement was not observed in any of the cases. A look at the respective advantages of each method reveals that calcification was best rendered visible via CT, small peripheral cysts with T2-weighted MRI, central necrosis with CT and MRI, and perihepatic invasion with multiplanar MRI. Vascular involvement was revealed by all methods. Conclusion: Color Doppler US, CT, and MR imaging function extremely well as complementary methods in the diagnosis of HAE. Color Doppler US should be performed in these patients owing to its ability to efficiently detect the disease. Knowledge of imaging characteristics makes it possible to radiologically ascertain an early diagnosis

  1. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  2. In-vivo imaging of blood flow dynamics using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2000-04-01

    Noninvasive quantitation of blood flow in the retinal micro circulation may elucidate the progression and treatment of ocular disorders including diabetic retinopathy, age-related degeneration, and glaucoma. Color Doppler optical coherence tomography was recently introduced as a technique allowing simultaneous micron-scale resolution cross-sectional imaging of tissue micro structure and blood flow in the human retina. Here, time-resolved imaging of dynamics of blood flow profiles was performed to measure cardiac pulsatility within retinal vessels. Retinal pulsatility has been shown to decrease throughout the progression of diabetic retinopathy.

  3. The application of color Doppler flow imaging in the diagnosis and therapeutic effect evaluation of erectile dysfunction

    Directory of Open Access Journals (Sweden)

    Xu-Jun Xuan

    2016-01-01

    Full Text Available We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg, prostaglandin E 1 (10 mg, and lidocaine (2%, 0.5-1 ml, the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades V to II. Then, the patients were given oral sildenafil (50-100 mg and scored according to the International Index of Erectile Function (IIEF-5 questionnaire. The number of patients with penile rigidities of Schramek Grades II to V was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P< 0.05, the peak systolic velocity (r = 0.45, P< 0.05, and penile rigidity (r = 0.75, P< 0.05, and was negatively correlated with the end diastolic velocity (r = −0.74, P< 0.05. For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction.

  4. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  5. Diagnosis of Cervical Abortion by TransvaginaI Color Doppler Sonography : A Case Report

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Ryu, Hee Sug; Ji, Hoon; Suh, Jung Ho

    1995-01-01

    Cervical abortion is a spontaneous abortion of an intrauterine pregnancy into the cervical canal where the abortus is retained by a closed external os, causing distension of the cervical canal. Cervical abortion should be distinguished from the cervical pregnancy. We present a case of cervical abortion diagnosed preoperatively by transvaginal sonography and color doppler imaging, and treated by dilatation and curettage. Charateristic transvaginal sonographic findings and identification of subtrophoblastic blood flow by color doppler imaging could allow differentiation of the cevical aborition from the cervical pregnancy

  6. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  7. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  8. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  9. Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

    Science.gov (United States)

    Turan, S; Turan, O M; Ty-Torredes, K; Harman, C R; Baschat, A A

    2009-06-01

    The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy. Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence: (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler. 107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%). Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester. (c) 2009 ISUOG.

  10. Experimental study on blood flow patterns through the phantoms of the intracranial arterial aneurysms using color Doppler imaging

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Jeong, Eun Kee; Rhim, Yoon Chul; Kim, Sung Bin; Lee, Dong Hoon; Kim, Dae In

    1994-01-01

    The occurrence, growth, thrombosis, and rupture of intracranial saccular aneurysms can be directly related to the effect of hemodynamic forces. We developed the phantom flow models and compared with the computer simulation program to analyse the flow pattern and hemodynamics that might be responsible for the intracranial arterial aneurysms. We designed the arterial phantoms of three major sites of intracranial arterial aneurysm ; 1) basilar artery tip, 2) internal carotid artery bifurcation, 3) curved area of internal carotid artery. Flow patterns in the aneurysmal portion of phantoms were evaluated with color Doppler system on the connection with automatic closed type of circulation system. Then, we compared the results with computer simulation. The hemodynamic characteristics of the phantoms were identical with those obtained by computerisation's. Three distinct zones of flow were identified by color Doppler studies on the aneurysm of the curved area of an internal carotid artery : 1) an inflow zone entering the aneurysm at the distal aspect of its orifice, 2) an outflow zone exiting the aneurysm at the proximal aspect of its orifice, 3) a central slow vortex.However, the phantoms of basilar artery tip and artery bifurcation showed a direct inflow stream at the dome of an aneurysm. Flow dynamics in the various phantoms of the aneurysms can be successfully evaluated with color Doppler imaging, and were consistent with those predicted by computer simulations

  11. Color Doppler Echocardiographic Assessment of Valvular Regurgitation in Normal Infants

    Directory of Open Access Journals (Sweden)

    Shu-Ting Lee

    2010-01-01

    Conclusion: The prevalence of inaudible valvular regurgitation is high in infants with structurally normal hearts. Multiple-valve involvement with regurgitation is not uncommon. Mild severity and low velocity on color Doppler, and the structural information provided by 2D imaging strongly suggest that these regurgitant flows are physiologically normal in infancy.

  12. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  13. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  14. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    International Nuclear Information System (INIS)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan; Hwang, Hee Yong

    1995-01-01

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  15. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  16. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  17. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  18. Digital storage and analysis of color Doppler echocardiograms

    Science.gov (United States)

    Chandra, S.; Thomas, J. D.

    1997-01-01

    Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

  19. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    International Nuclear Information System (INIS)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub

    1997-01-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary β-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary β-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN

  20. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  1. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  2. [Vascular complications following kidney transplant: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale

    2012-01-01

    The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.

  3. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  4. Power and color Doppler ultrasound settings for inflammatory flow: impact on scoring of disease activity in patients with rheumatoid arthritis.

    Science.gov (United States)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin; Ellegaard, Karen; D'Agostino, Maria Antonietta; Iagnocco, Annamaria; Naredo, Esperanza; Balint, Peter; Wakefield, Richard J; Torp-Pedersen, Arendse; Terslev, Lene

    2015-02-01

    To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. Six different types of ultrasound machines were used. On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. Power Doppler was more sensitive on half of the machines, whereas color Doppler was more sensitive on the other half, using both factory settings and study settings. There was an average increase in Doppler sensitivity, despite modality, of 78% when study settings were applied. Over the 6 machines, 2 Doppler modalities, and 2 settings, the grades for each of 7 of the patients varied between 0 and 3, while the grades for each of the other 4 patients varied between 0 and 2. The effect of using different machines, Doppler modalities, and settings has a considerable influence on the quantification of inflammation by ultrasound in RA patients, and this must be taken into account in multicenter studies. Copyright © 2015 by the American College of Rheumatology.

  5. Color doppler energy (CDE) : initial ten-months experience

    International Nuclear Information System (INIS)

    Ro, Young Jin; Son, Hyun Ju; Lee, Suck Hong; Kim, Byung Soo; Han, Kook Sang; Nam, SAng Hwa; Lee, Keum Seob; Shin Se Kwon

    1996-01-01

    Color Doppler imaging(CDI) has shortcomings, including random noise, aliasing, and angle dependence. To overcome these, a method using CD US, termed power doppler or Color Doppler Energy(CDE), has recently been introduced. The purpose of this study was to show the clinical usefulness of CDE. We retrospectively analyzed the CDI and CDE of 61 cases(20 renal pseudotumors, 8 musculoskeletal inflammations, 17 epididymitis or epididymo-orchitis, 3 varicoceles, 1 normal testis, 1 hepatocellualr carcinoma, 7 renal cell carcinoma, 1 renal angiomyolipoma, and 3 splenic varices). CDI and CDE scans were obtained at the same region with constant scan plane. The color gain was increased until noise first became perceptible, and scans were always obtained in such a way that the maximum amount of vascularity was shown. Thereafter, the vascularity, vascular displacement, and the vascular relationship between CDI and CDE were compared. In 17 of 20 cases of pseudotumor in the kidney, normal vascularity was identified in CDI and CDE, but was more cleary visible in CDE. In three cases, there was no visible vascularity in CDI, but normal vascularity in CDE. In eight cases of musculoskeletal inflammation and 17 cases of epididymitis with or without orchitis, the vascularity was increased due to hyperemia, which was more prominently seen in CDE than in CDI. In three varicoceles, CDE appeared to be better in demonstrating low velocity flow. In one patient who was suspected of having acute testicular torsion, CDE was helpful in excluding this suspicion. In one case of hepatocellualr carcinoma, seven cases of renal cell carcinoma, one case of renal angiomyolipoma, and three cases of splenic varices, CDE was better than CDI in showing the vascularity, vascular relationship, and vascular displacement

  6. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  7. Evaluation of diagnosis of small breast cancer with high frequency and color doppler ultrasound

    International Nuclear Information System (INIS)

    Xia Guobing; Hu Chunhong; Jing Qiulong

    2008-01-01

    Objective: To probe the features of high frequency ultrasonography (HFU) and color Doppler ultrasound (CDU) in the case of small breast cancers in order to evaluate the diagnostic value for small breast cancer with CDU. Methods: The features of HFU and CDU were respective analyzed in 67 small breast masses, the biggest diameter of which was under 2cm identified with pathology. Results Partially characteristic changes of small breast cancers were displayed, and micro-calcification within the mass was an important characteristic, in addition, the Resistant Index (RI) ≥ 0.70 on Pulsed Doppler (PD) and the grade of blood flow on Color Doppler Flow Imaging (CDFI)≥T2 implied much more positive malignancy prediction. Conclusion: HFU integrated with CDU can be used for the early and accurate diagnosis of the small breast cancer. (authors)

  8. Diagnostic accuracy of color Doppler flow imaging and Duplex US in peripheral arterial disease

    International Nuclear Information System (INIS)

    Karmel, M.I.; Polak, J.F.; Whittemore, A.D.; Mannick, J.A.; Donaldson, M.C.; O'Leary, D.H.

    1988-01-01

    Color Doppler flow imaging (5 MHz) and Duplex US were used in a prospective examination of 154 arterial segments in the lower extremities of 11 symptomatic patients. Each extremity was divided into seven arterial segments (common femoral, profunda femoral, proximal, middle, and distal superficial femoral, and proximal and distal popliteal arteries). Arterial maps were drawn for each patient and compared with the arteriograms. Seventeen significant stenoses and 18 complete occlusions were predicted and confirmed by means of arteriography. Four significant stenoses and four occlusions were predicted and not confirmed. One hundred nine normal arterial segments were correctly predicted. No significant stenoses or occlusions were missed. Prospective identification of the severity and location of disease can help to optimize both the angiographic approach and hospital services utilization

  9. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  10. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  11. Usefulness of hemodynamically distribution of intranodal vessels in differentiating metastatic neck lymph nodes-value of color doppler and spectral wave sonogram

    International Nuclear Information System (INIS)

    Mumtaz, U.

    2017-01-01

    Objective: To evaluate the diagnostic assessment of enlarged lymph nodes, based on its perfusion pattern by taking tissue diagnosis as gold standard. Study Design: Analytical study. Place and Duration of Study: Departments of Radiology and Pathology, PIMS Hospital, Islamabad, from February to May 2016. Methodology: Color sonography of patients with clinically, palpable cervical lymph nodes were carried by senior trainee under the supervision of senior radiologist. Ultrasound guided tissue diagnosis was obtained in all suspected malignant cases. Histopathology was taken as the gold standard for determining accuracy. Results: Accuracy, sensitivity and specificity, positive and negative predictive values of color Doppler ultrasound in detecting malignant cervical lymphadenopathy was found to be 88.46%, 86.05%, 79.31% and 92.50%, respectively with diagnostic accuracy of 86.95%, when intranodal vascular pattern on color Doppler imaging was analyzed. Using spectral wave indexes, the same values were 92.31%, 90.70%, 85.71%, 95.12%, respectively with overall diagnostic accuracy of 91.30%. Conclusion: Color Doppler sonography is much sensitive borderline than grey scale findings alone. Furthermore, lymph nodes appearing in the detection of malignant nodes on grey scale images can be reliably diagnosed on Doppler scan. (author)

  12. Color/power Doppler transrectal US in prostate cancer: Correlation with Gleason score

    International Nuclear Information System (INIS)

    Kim, Hyo Cheol; Kim, Seung Hyup; Moon, Min Hoan; Park, Byung Kwan; Kim, Keon Ha; Choi, Hyuck Jae; Yoon, Chang Jin

    2002-01-01

    To evaluate the relationship between hypervascularity on color/power Doppler transrectal ultrasonography and the Gleason score of corresponding biopsied specimen in patients with prostatic cancer. From July 1998 to March 2002, one hundred fifty seven patients with pathologically proven prostate cancer at this institution were included, and all of them underwent transrectal ultrasonographic examination. Initially, ultrasonographic findings and pathologic data of 129 patients were retrospectively reviewed and excluded 28 patients whose sonographic images were either unavailable or inconclusive. The presence of hypoechoic lesion on transrectal sonography and hypervascularity on color/power Doppler sonography in the peripheral zone of the prostate was first evaluated, and these sonographic findings and Gleason score of the corresponding biopsied specimen were then compared. Statistical analysis was done by Student t-test using SPSS package. Among one hundred twenty nine patients, ninety four patients had a hypoechoic lesion on gray scale sonography while sixty one showed a hypervascular lesion on color/power Doppler sonography. Fifty seven of 61 patients (93.4%) had hypoechoic lesion on gray scale sonography. The mean Gleason score of patients with hypervascular lesion was 7.9 ± 0.98 whereas that of the patients without hypervascular lesion, 6.9 ± 1.22, showing a statistically significant difference (p<0.01). Prostate cancer with hypervascularity on transrectal sonography appears to have a higher Gleason score on pathologic examination than that without hypervascularity.

  13. Color doppler flow imaging in evaluation of uterine arterial embolization of leiomyoma with KMG

    International Nuclear Information System (INIS)

    Li Furong; Guo Yunhuai; Liu Lifang; Liu Jianhua; Guo Yunhuai

    2006-01-01

    Objective: To explore the effectiveness of a new kind of embolization agent-sodium alginate(KMG), and to evaluate the clinical value of 2D color Doppler ultrasound in assessing the therapeutic effect of uterine arterial embolization (UAE) in leiomyomas. Methods: Forty nine patients with symptomatic leiomyomas were undertaken UAE with KMG for the treatment. Sonography was performed at 3-7 days before and, 1, 3, 6 months after UAE with 2D color Doppler for evaluating the 2D echograms and hemodynamics. Results: Forty nine leiomyomas were studied after UAE, showing a marked reduction in the size (35%-90%). No blood flow was demonstrated in the leiomyomas either 3-7 days or 1 month or 3 months after the procedure. The reappearance of blood flow could be seen in only one case. Conclusion: KMG is an efficient embolization agent for the treatment of symptomatic leiomyomas with UAE, and ultrasonography is a useful tool to assess the effectiveness. (authors)

  14. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  15. A feasability study of color flow doppler vectorization for automated blood flow monitoring.

    Science.gov (United States)

    Schorer, R; Badoual, A; Bastide, B; Vandebrouck, A; Licker, M; Sage, D

    2017-12-01

    An ongoing issue in vascular medicine is the measure of the blood flow. Catheterization remains the gold standard measurement method, although non-invasive techniques are an area of intense research. We hereby present a computational method for real-time measurement of the blood flow from color flow Doppler data, with a focus on simplicity and monitoring instead of diagnostics. We then analyze the performance of a proof-of-principle software implementation. We imagined a geometrical model geared towards blood flow computation from a color flow Doppler signal, and we developed a software implementation requiring only a standard diagnostic ultrasound device. Detection performance was evaluated by computing flow and its determinants (flow speed, vessel area, and ultrasound beam angle of incidence) on purposely designed synthetic and phantom-based arterial flow simulations. Flow was appropriately detected in all cases. Errors on synthetic images ranged from nonexistent to substantial depending on experimental conditions. Mean errors on measurements from our phantom flow simulation ranged from 1.2 to 40.2% for angle estimation, and from 3.2 to 25.3% for real-time flow estimation. This study is a proof of concept showing that accurate measurement can be done from automated color flow Doppler signal extraction, providing the industry the opportunity for further optimization using raw ultrasound data.

  16. Vesico-ureteral reflux: diagnosis and staging with voiding color doppler US Preliminary experience

    International Nuclear Information System (INIS)

    Farina, Renato; Arena, Carmela; Pennisi, Francesco; Di Benedetto, Vincenzo; Politi, Guido; Di Benedetto, Aurelio

    2000-01-01

    Introduction: The aim of this study is to assess the accuracy of a new US examination: 'voiding color Doppler US ' in the early diagnosis and staging of vesico-ureteral reflux (VUR). The contrast agent US was SH U 508A (Levovist, Schering, Berlin), which produces a chromatic accentuation of the signals picked up by the color Doppler US. Eighteen patients (10 females, eight males) were recruited for the study. In two patients a second examination was performed for follow-up after a VUR conservative therapy. All patients were taken under examination for the evaluation of possible VUR. In all patients the voiding color Doppler US was followed by voiding cystourethrography (VCUG) and the data obtained were compared. Materials and methods: A total of 18 patients aged between 3 months and 10 years, were recruited for the study. The results of the examination were the following: urinary tract infections, follow-up of VUR after conservative or surgical therapy, miscellaneous indications. Voiding color Doppler US was performed, followed by a VCUG. The voiding color Doppler US consists in the trans-catheter introduction of a contrast agent SHU 508 A (Levovist, Schering, Ag. Berlin) into the bladder and a subsequent test with the color Doppler US to show or exclude the presence of reflux into the ureters and/or into the pyelo-caliceal cavity of the kidneys. After the introduction of the contrast agent US the ultrasound scanning of the bladder, the ureters and the pyelo-caliceal cavity was performed to examine the reflux degree. The ultrasonographic investigations were perfomed with AU 590 asyncronus US (Esaote Biomedica, Genova) with a 3.5 MHz convex probe. Results: After the trans-catheter introduction of the contrast agent US, vesico-ureteral reflux occured in 13 patients (77.2%). The reflux degree was also measured by means of ultrasound and was later confirmed by VCUG. The mean times of each examination were as follows: initial US, 10 min; catheterization, 8 min; voiding

  17. Corpus luteum blood flow in normal and abnormal early pregnancy: evaluation and analysis with transvaginal color and pulsed doppler sonography

    International Nuclear Information System (INIS)

    Tang Xiaoyi; Lin Meifang; Zheng Meirong; Liang Xiaoxian; Liu Jianfeng

    2005-01-01

    Objective: Detecting and assessment the corpus luteum blood flow in normal and abnormal early pregnancy. Methods: Using transvaginal color and pulse Doppler sonography, we detected 215 pregnant women including 150 normal intrauterine pregnancies, 25 abortion, 29 ectopic pregnancies, and then recorded corpus luteum blood flow feature and the blood flow indexes (Vmax, RI and PI). Results: 1) Corpus luteum was successfully identified in 148 cases out of 150 of normal early pregnancies, 25 cases out of 26 of threatened abortion; 22 cases out of 29 of ectopic pregnancy. 2) Three groups shared the same feature of Color Doppler imaging: a circumferential rim around the entire corpus luteum. 3) The flow index revealed mean PVS, RI and PI had no statistical difference in normal and abnormal early pregnancy; The mean PVS was lower in ectopic pregnancy than in normal pregnancy (P<0.05), while PI and PR had no characteristic in ectopic pregnancy group compared with the indexes obtained in normal pregnancy group. Conclusion: The corpus luteum can be precisely identified in most pregnancy using transvaginal color Doppler and manifests a characterized rim Doppler imaging. PVS may help in differentiating the ectopic pregnancy from normal early pregnancy. (authors)

  18. Ultrasonographic investigation of the Achilles tendon in elite badminton players using color Doppler.

    Science.gov (United States)

    Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren

    2006-12-01

    The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced

  19. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  20. The use of contrast-enhanced color doppler ultrasound in the differentiation of retinal detachment from vitreous membrane

    International Nuclear Information System (INIS)

    Han, Sang Suk; Chang, Seung Kook; Yoon, Jung Hee; Lee, Young Joon

    2001-01-01

    To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD

  1. High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography

    NARCIS (Netherlands)

    van Leeuwen, T. G.; Kulkarni, M. D.; Yazdanfar, S.; Rollins, A. M.; Izatt, J. A.

    1999-01-01

    Color Doppler optical coherence tomography (CDOCT) is capable of precise velocity mapping in turbid media. Previous CDOCT systems based on the short-time Fourier transform have been limited to maximum flow velocities of the order of tens of millimeters per second. We describe a technique, based on

  2. [Current role of color Doppler ultrasound in acute renal failure].

    Science.gov (United States)

    Bertolotto, M; Quaia, E; Rimondini, A; Lubin, E; Pozzi Mucelli, R

    2001-01-01

    Acute Renal Failure (ARF) is characterized by a rapid decline of the glomerular filtration rate, due to hypotension (prerenal ARF), obstruction of the urinary tract (post-renal ARF) or renal parenchymal disease (renal ARF). The differential diagnosis among different causes of ARF is based on anamnesis, clinical symptoms and laboratory data. Usually ultrasound (US) is the only imaging examination performed in these patients, because it is safe and readily available. In patients with ARF gray scale US is usually performed to rule out obstruction since it is highly sensitive to recognize hydronephrosis. Patients with renal ARF have no specific changes in renal morphology. The size of the kidneys is usually normal or increased, with smooth margins. Detection of small kidneys suggests underlying chronic renal pathology and worse prognosis. Echogenicity and parenchymal thickness are usually normal, but in some cases there are hyperechogenic kidneys, increased parenchymal thickness and increased cortico-medullary differentiation. Evaluation of renal vasculature with pulsed Doppler US is useful in the differential diagnosis between prerenal ARF and acute tubular necrosis (ATN), and in the diagnosis of renal obstruction. Latest generation US apparatus allow color Doppler and power Doppler evaluation of renal vasculature up to the interlobular vessels. A significant, but non specific, reduction in renal perfusion is usually appreciable in the patients with ARF. There are renal pathologic conditions presenting with ARF in which color Doppler US provides more specific morphologic and functional information. In particular, color Doppler US often provides direct or indirect signs which can lead to the right diagnosis in old patients with chronic renal insufficiency complicated with ARF, in patients with acute pyelonephritis, hepatic disease, vasculitis, thrombotic microangiopathies, and in patients with acute thrombosis of the renal artery and vein. Contrast enhanced US is

  3. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    Directory of Open Access Journals (Sweden)

    Ali A. Hasan

    2013-07-01

    Conclusions: Application of color Doppler examination increases the accuracy of real time chest ultrasound to discriminate pleural thickening from minimal pleural effusion and hence color Doppler examination proved to be a useful diagnostic tool to real-time gray-scale ultrasound for diagnosis of minimal pleural effusion.

  4. Color Doppler Score: A New Approach for Monitoring a Large Placental Chorioangioma

    Directory of Open Access Journals (Sweden)

    Maria Angelica Zoppi

    2014-01-01

    Full Text Available We employed color Doppler score as an innovative approach for the prenatal diagnosis and monitoring of a large placental chorioangioma case diagnosed at 26 weeks and the subjective semiquantitative assessment of the vascularization. The blood flow was assessed by a color Doppler score based on the intensity of the color signal with the following value ranges: (1 no flow, (2 minimal flow, (3 moderate flow, and (4 high vascular flow. Weekly examinations were programmed. Initially, a color Doppler score 3 was assigned, remaining unchanged at the following two exams and decreasing to Score 2 in the following 2 exams and to Score 1 thereafter. The ultrasonographic scan showed an increase of the mass size at the second and third exams and was followed by an arrest of the growth persisting for the rest of the pregnancy. Some hyperechogenic spots inside the mass appeared at the end. Expectant management was opted for, and the delivery was at 39, 2 weeks and maternal and fetal outcomes were favourable. The color Doppler score employed for assessment of vascularization in successive examinations proved to be an important tool for the prediction of the chorioangioma involution, and this new approach of monitoring allowed effective surveillance and successful tailored management.

  5. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  6. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  7. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  8. Diagnosis of post-partum ovarian vein thrombophlebitis by color Doppler ultrasonography: about 10 cases.

    Science.gov (United States)

    Giraud, J R; Poulain, P; Renaud-Giono, A; Darnault, J P; Proudhon, J F; Grall, J Y; Mocquet, P Y

    1997-09-01

    Post-partum ovarian vein thrombosis is often overlooked or mistaken for other complications such as endometritis. Color Doppler ultrasonography is a very good diagnostic method when properly indicated and correctly interpreted according to clinical data. This study reports ten cases that were retrospectively studied, during which color Doppler ultrasonography was used. The clinical signs and the results are reviewed. The lesions were clearly visualized in eight of the ten cases; one of the two failures resulted from a methodological fault (uninterpretable result); the other one was due to the lack of experience of the operator and nonrecognition of the clinical signs. Thrombosis appears as a hypoechogenic and tubular image. This type of examination is particularly indicated in the presence of certain clinical signs that were observed in our cases: fever and iliac pain are the main precursor signs, often associated with abdominal meteorism and slow digestive transit; provoked cul-de-sac pain during vaginal probing was the only constant sign, sometimes associated with painful swelling.

  9. Contrast-enhanced color Doppler US in breast cancer: Tumoral vascularity correlated with angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Yun, Ki Jung; Lee, Kwang Man; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [Wonkwang University School of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate the effects of contrast-enhanced color Doppler ultrasonography (CDUS) on the depiction of vascularity and flow pattern in breast cancer and to determine the relationship between tumoral vascularity and angiogenesis. Twenty-one patients with breast cancer were prospectively evaluated with CDUS before and after injection of the contrast agent (SH U 508A, 2.5g, 300 mg/ml ). The tumoral vascularity was expressed as percentage of color Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The flow pattern (four-patterns; spotty, linear, branching, marginal) of the vascularity was analyzed. After surgery, tumor angiogenesis was assessed by microvessel density. The relationship between the vascularity on CDUS and microvessel density was statistically analyzed. At unenhanced CDUS, tumoral flow signals were detected in 12 lesions (48%); at contrast-enhanced CDUS, 18 lesions (86%). All These 18 lesions showed increased signals, compared with those at unenhanced CDUS. The percentage color Doppler area was 1.86 {+-} 0.48% at unenhanced CDUS and 5.23 {+-} 1.18% at contrast-enhanced CDUS. The flow patterns before contrast injection were spotty pattern in 11 tumors and linear pattern in one; after contrast injection, spotty in 8, linear in 4, branching in 5, and marginal in one. The tumoral vascularity at contrast-enhanced CDUS showed no significant correlation with microvessel density. Contrast-enhanced CDUS seems to be a valuable tool in the depiction of vascularity and characterization of flow pattern in breast cancer. However, tumoral vascularity on CDUS may not reflect tumoral angiogenesis.

  10. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity.

  11. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    International Nuclear Information System (INIS)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung

    1997-01-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity

  12. Color doppler findings of gastric varices compared with findings on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Suga, Toshihiro [Sapporo Kosei General Hospital (Japan)

    2002-08-01

    The aim of this study was to evaluate the hemodynamics of gastric varices. We evaluated the detection rates of gastric varices, inflowing vessels to gastric varices, and outflowing vessels from gastric varices in 24 patients with gastric varices, using color Doppler sonography, and compared these findings with computed tomography findings. Eighteen patients had F2-type varices and 6 had F3-type, classified according to the Japanese Research Society for Portal Hypertension. Fourteen patients had fundal varices, and 10 had cardiac and fundal varices. The detection rates of collateral veins using color Doppler sonography were as follows: gastric varices were detected in all 24 patients (100%); inflowing vessels, in 21 of the 24 patients (87.5%); and outflowing vessels, in 18 of the 24 patients (75.0%). The detection rates of collateral veins, using computed tomography, were: gastric varices were detected in all 24 patients (100%); inflowing vessels, in all 24 patients (100%); and outflowing vessles, in 21 of the 24 patients (87.5%). The color Doppler findings agreed perfectly with the computed tomography findings in 13 of the 24 patients (54.2%). Although color Doppler sonography is a useful, noninvasive modality for evaluating the hemodynamics of gastric varices, it falls short in visualizing the detailed hemodynamics of the inflowing and outflowing vessels of gastric varices in half of the patients when compared with computed tomography. (author)

  13. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2011-01-01

    hypertrophy, effusion) and by color Doppler (synovial hyperemia) before and 4 weeks after US-guided steroid injection. Results US detected 121 compartments with active disease (joints, tendon sheaths and 1 ganglion cyst). Multiple compartments were involved in 80% of the ankle regions. The talo-crural joint...

  14. The diagnosis value of color doppler ultrasound in evaluating small renal carcinoma

    International Nuclear Information System (INIS)

    Chen Gaiyi

    2009-01-01

    Objective: To characterize the ultrasound and color doppler imaging of small renal carcinoma. Methods: Ultrasound and color doppler images by convex-probe and high frequency-probe of 24 patients with renal carcinoma confirmed by surgery and histology were analyzed retrospectively. Tumor echo, halo, internal blood flow and peripheral tumor blood flow were observed. Results: Tumor echo in 9 lesions was hyper-echo, in 4 was iso-echoic, in 10 was hypo-echo, and in 1 was echoless. Halo was detected in 9 tumors, and small cyst was detected in 5 tumors. By using the convex-probe, peripheral and internal blood flow signal in 24 tumors were observed. Spot blood follow was detected in 6 tumors, half-circularity blood follow in 18 tumors and no circularity blood follow. Detection rate of internal blood flow was 20.83%. By using the high frequency-probe in 21 tumors, spot blood was detected in 1 tumor, half-circularity blood follow in 14 tumors, circularity blood follow in 6 tumors. Detection rate of internal blood flow was 90.48%. It was not satisfied for high frequency-probe in 3 patients because of obesity. Accordance of the diagnosis by high frequency-probe ultrasound was 90.48% and 91.67% by CT (P > 0.05). Conclusion: Detection of renal carcinoma is sensitive by ultrasound. The high frequency-probe is significant sensitive to detect blood follow in renal carcinoma and is helpful to correct diagnosis of renal carcinoma. (authors)

  15. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  16. Study of retrobulbar hemodynamics in diabetes via color doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2014-09-01

    Full Text Available AIM: To explore the changes of retrobulbar hemodynamics in diabetes via color doppler ultrasound. METHODS: Totally 80 patients(160 eyeswith eye diseases in type 2 diabetes from June 2010 to May 2013 in our hospital were enrolled as research group. By fundus photography and direct ophthalmoscopy, patients were assigned to diabetes without retinopathy group(DNR subgroup, non-proliferative diabetic retinopathy group(NPDR subgroupand proliferative diabetic retinopathy group(PDR subgroup. Of 60 healthy patients(120 eyesover the same period were chosen as control group. The doppler parameters of central retinal artery(CRA, posterior ciliary artery(PCAand ophthalmic artery(OAwere measured.RESULTS: There were significant differences on circulatory parameters of CRA, PCA and OA between both groups(PPPCONCLUSION: The monitoring of retinal blood flow and analysis of blood spectrum morphology via color doppler ultrasound can effectively evaluate the degree of diabetic retinopathy lesions, especially before DR vascular disease. Early detection can reveal the hemodynamic change pattern of DR, facilitating the prevention of diabetic eye complications and improvement of the quality of life.

  17. Analysis on correlation between overall classification on color doppler ultrasound and clinical stages of atherosclerosis obliterans

    International Nuclear Information System (INIS)

    Zhang Dongmei; Liu Meihan; Shi Weidong; Chen Enqi; Li Xinying; Lin Yu

    2010-01-01

    Objective: To investigate the correlation and the clinical significance between the overall classification on color Doppler ultrasound and the clinical stages of atherosclerosis obliterans (ASO), and evaluate the extent of arterial lesions comprehensively. Methods: 125 patients of ASO, who were divided into three groups of mild, moderate and severe with Color Doppler ultrasound according to differences of occlusion, quantity, degree of stenosis and collateral number, were analyzed with clinical stages, then their associations were studied with Spearman rank analysis. Results: The clinical manifestations of ASO patients who were divided into three groups of mild, moderate and severe according to overall classification on color Doppler ultrasound were respectively gradually serious, which had positive correlations with the stages of I, II and III according to clinical stages. Spearman rank analysis showed that the correlation coefficients (rs)was 0.797 2 between two groups (P<0.01), there was good consistency between the overall classification on color Doppler ultrasound and the clinical stagesof ASO. Conclusion: The overall classification of ASO on color Doppler ultrasound has considered impact of many other factors on the clinical symptoms,such as the level of the local narrow, narrow scope, segments of occlusion and collateral arteries, which divides the lesions more objectively, shows good consistency with the clinical stages. (authors)

  18. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    Science.gov (United States)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  19. Studi Penentuan Kecepatan Aliran Darah dan Frekuensi Terimaan Pasien Atherosclerosis Menggunakan USG Color Doppler

    OpenAIRE

    Mulyani, Emba

    2014-01-01

    Jurnal Fisika Medik Studi Penentuan Kecepatan Aliran Darah dan Frekuensi Terimaan Pasien Atherosclerosis Menggunakan USG Color Doppler Mulyani H211 08 507 Pembimbing Utama Sri Dewi Astuty Ilyas,Ssi, Msi Nip.19750513 199903 2 001 Pembimbing Pertama Dahlang Tahir, Msi, Ph.D Nip.19750907 200003 1 001 ABSTRACT Research about Study of determination blood speed of current and freq uency give patient atherosclero sis uses plane USG Color Doppler had be...

  20. Análisis de perforantes de la epigástrica inferior profunda con Angio TC 3D, Eco Doppler color y Doppler simple de ultrasonidos en colgajo DIEP: resultados preliminares Analysis of deep inferior epigastric perforating vessels with 3D CT angiography, color Doppler ultrasonography and Doppler in diep flaps: preliminary results

    Directory of Open Access Journals (Sweden)

    J. Castro García

    2008-09-01

    Full Text Available Nuestro objetivo es la validación de la Angio TC tridimensional como herramienta de planificación de los colgajos DIEP, comparándolo con el Doppler de ultrasonidos (US y eco Doppler color. Entre enero de 2006 y marzo de 2007 se realiza en 11 pacientes (13 DIEP un estudio comparativo prospectivo entre el Doppler de US, eco Doppler color y Angio TC con reconstrucción tridimensional, utilizando como dato de referencia los hallazgos intraoperatorios. En dicho proceso se localiza la mejor perforante que pueda servir como pedículo al colgajo DIEP en función de su localización, calibre, trayecto y relaciones anatómicas con respecto al músculo. La Angio TC con reconstrucción tridimensional, demuestra una especificidad del 100% (IC 95% 75.3-100 lo que le convierte en una prueba con un alto valor predictivo positivo y una excelente herramienta en la planificación de los colgajos de perforantes. El eco Doppler color determinó, que tan sólo en un 46,1% (IC 95% 19,2-74,9 de los pacientes, la perforante seleccionada por la prueba de forma preoperatoria, coincidía con la perforante elegida en quirófano. Con el Doppler de US, en un 30,8 % (IC 95% 9,1-61,4 de los colgajos estudiados, coincidía la mejor perforante escogida de forma preoperatoria, con los hallazgos obtenidos tras la disección del colgajo. En el presente estudio, la Angio TC tridimensional se ha mostrado como una técnica con una gran especificidad que proporciona valiosa información, sólo comparable con la disección anatómica y por delante de pruebas como el Doppler de ultrasonidos y el eco Doppler color.The aim of this report, is to validate the Angio-CT technique with three-dimentional reconstruction as a preoperative planning tool, after comparison with Doppler ultrasound and color- Duplex. Between january 2006 and march 2007, we studied 11 consecutive patients (13 DIEP in whom a prospective comparative followed up was performed comparing, the findings observed using

  1. [The diagnostic performance of color Doppler ultrasonography for newborn four cases of midgut volvulus accompanied by intestinal malrotation].

    Science.gov (United States)

    Ikeshima, Yukari; Hisano, Katsuya; Morisawa, Takeshi; Inoue, Kozue; Shimamoto, Masahiro; Koujitani, Toshiaki; Yonetani, Masahiko; Yasufuku, Masao

    2014-03-01

    Midgut volvulus accompanied by intestinal malrotation is classified as a surgical emergency disease of the newborn, which emerges with the bilious vomiting or melena. This report presents four patients of this disease in our hospital, evaluated by color Doppler ultrasonography before surgical operation. All four patients were presented by bilious vomiting at the onset. By color Doppler ultrasonography method, the whirlpool sign which is the view of intestine and superior mesenteric vein rotated around with the axis of superior mesenteric artery, were shown in all cases. This whirlpool sign led to the diagnosis of midgut volvulus accompanied by intestinal malrotation. Intestinal contrast imaging was tested in three patients for the purpose of confirming the diagnosis. Repair of the volvulus and a ladd operation was performed in all four patients, without the excision of intestine because of no intestinal ischemic change. The clinical courses of four cases were good, and all patients were discharged within 17 days. Early diagnosis and timely surgical operation are essential for decreasing the possibility of occurring intestinal ischemic changes and improving clinical outcome after surgical operation. We propose that color Doppler ultrasonography is the powerful tool for the diagnosis of this disease, especially for the newborn, for whom the available diagnostic tests are limited.

  2. Vascular response to ischemia in the feet of falanga torture victims and normal controls--color and spectral Doppler findings

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Amris, Kirstine; Holm, Christian Cato

    2009-01-01

    to controls. On color Doppler this would be seen as less color after ischemia and on spectral Doppler as elevated resistive index (RI). METHODS: Ten male torture victims from the Middle East and nine age, sex and ethnically matched controls underwent Doppler examination of the abductor hallucis and flexor...... digitorum brevis muscles before and after two minutes ischemia induced with a pressure cuff over the malleoli. The color Doppler findings were quantified with the color fraction (CF) before and after ischemia. On spectral Doppler the resistive index was measured once before and three consecutive times after....... However, the trend in RI still supports the hypothesis. The negative findings may be due to inadequate design where the CF and RI were measured in one setting, perhaps resulting in both methods being applied imperfectly. The response to ischemia seems short-lived and we suggest that the Doppler methods...

  3. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  4. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    Science.gov (United States)

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  5. High resolution compression elastography and color doppler sonography in characterization of breast fibroadenoma.

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reu, S; Deak, Z; Hetterich, H; Kolben, T; Reiser, M; Clevert, D A

    2014-01-01

    To evaluate the use of color Doppler sonography and free hand sonoelastography in the assessment of breast fibroadenomas according to their size and shape. From December 2012 to March 2013 women with 16 solid breast masses, classified as BI-RADS category 3 or 4 were examined with B-mode ultrasound, sonoelastography and color Doppler sonography. Lesions were subdivided according to their shape in round, ovoid or macrolobulated and according to their size (fibroadenomas in B-mode sonography could be shown (p = 0.91) and also comparison of Tsukuba-scores and size of masses revealed no significant differences (p = 1.0). Sizes of fibroadenomas ≥2 cm were significantly associated with an increased vascularization of the lesions (p = 0.04) and a macrolobulated appearance in B-mode sonography (p = 0.04). The combination of color Doppler sonography and sonoelastography in addition to B-mode sonography leads to an increased accuracy in distinguishing benign from malignant breast masses and to an improvement in characterization of fibroadenomas independent of their shape or size.

  6. Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis

    Science.gov (United States)

    Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami

    2013-01-01

    AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754

  7. Cavernous hemangioma of liver: a comparative study of MRI and color Doppler ultrasound (with 58 case report)

    International Nuclear Information System (INIS)

    Luan Zhiyong; Xu Weidong; Wang Jiazhong

    2006-01-01

    Objective: To evaluate MRI and the color Doppler ultrasound in the diagnosis of cavernous hemangioma of liver. Methods: In total 58 patients with hemangioma of liver underwent dynamic enhanced MRI and the color Doppler ultrasound examination. The imaging manifestations obtained by both modalities were comparatively studied. Result: Highly echoic lesions were revealed in 36 cases out of 58; low echoic lesions were noted in 8; and in 14 cases the tumors were of mixed echoic. On T 1 WI the lesions were hypo- or slightly hypo-intense; while on T 2 WI they were hyper- or slightly hyper-intense. The nidi were hyper-intense on T 2 WI of CRE array. On enhanced scan the lesions were quickly fully enhanced in 25 cases out of 58. Peripheral nodular enhancement was seen in 19 cases, and centered spreading enhancement was demon- strated in 14 cases. On delayed scan remarkable homogenous enhancement was observed in all cases. Conclusion: The bigger size has the hemangioma, the smaller highly echoic proportion and bigger mixed echoic or poorly echoic proportion will be found within the lesions. More peripheral nodular enhancement will be revealed on enhanced MRI scan when the tumor size is getting larger, in which the proportion of quickly fully enhancement will decrease gradually. Ultrasound is better than MRI in the evaluation of the liver hemangioma smaller than 3 cm in diameter. MRI is superior to color Doppler ultrasound in diagnosing the lesion larger' than 3 cm in diameter. (authors)

  8. Color Doppler imaging of the retrobulbar circulation in progressive glaucoma optic neuropathy.

    Science.gov (United States)

    Magureanu, Marineta; Stanila, Adriana; Bunescu, Liviu Valentin; Armeanu, Cristina

    2016-01-01

    It is known that elevated intraocular pressure (IOP) is the primary risk factor for glaucoma. Recently, more and more evidences have shown that the vascular deficit also plays an important role in the pathogenesis and progressions of glaucomatous optic neuropathy. This issue is backed up by glaucomatous optic neuropathy (GON) cases drug compensated in which the progression of the disease in one or both eyes is ascertained despite a normal and relatively constant IOP. The present study evaluated the hemodynamic parameters in the retrobulbar circulation in patients with progressive glaucomatous optic neuropathy in one eye, who received compensated medication. The hemodynamic parameters (PSV, EDV, IR) were measured by using color Doppler ultrasound and progression was evaluated by a repeated automated perimetry. The obtained values were statistically analyzed and compared with those obtained for the stable eye.

  9. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis [Department of Radiology, Medical School, University of Ioannina, 45110, Ioannina (Greece); Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani [Neonatology Clinic, Medical School, University of Ioannina, 45110, Ioannina (Greece); Vartholomatos, Georgios A. [Department of Haematology, Medical School, University of Ioannina, 45110, Ioannina (Greece)

    2003-08-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  10. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    International Nuclear Information System (INIS)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis; Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani; Vartholomatos, Georgios A.

    2003-01-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  11. Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation.

    Science.gov (United States)

    Garcia, M J; Smedira, N G; Greenberg, N L; Main, M; Firstenberg, M S; Odabashian, J; Thomas, J D

    2000-01-01

    To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.

  12. Basal ganglia perfusion using dynamic color Doppler sonography in infants with hypoxic ischemic encephalopathy receiving therapeutic hypothermia: a pilot study.

    Science.gov (United States)

    Faingold, Ricardo; Cassia, Guilherme; Morneault, Linda; Saint-Martin, Christine; Sant'Anna, Guilherme

    2016-10-01

    The objective of this study was to evaluate the cerebral perfusion of the basal ganglia in infants with hypoxic-ischemic encephalopathy (HIE) receiving hypothermia using dynamic color Doppler sonography (CDS) and investigate for any correlation between these measurements and survival. Head ultrasound (HUS) was performed with a 9S4 MHz sector transducer in HIE infants submitted to hypothermia as part of their routine care. Measurements of cerebral perfusion intensity (CPI) with an 11LW4 MHz linear array transducer were performed to obtain static images and DICOM color Doppler videos of the blood flow in the basal ganglia area. Clinical and radiological data were evaluated retrospectively. The video images were analyzed by two radiologists using dedicated software, which allows automatic quantification of color Doppler data from a region of interest (ROI) by dynamically assessing color pixels and flow velocity during the heart cycle. CPI is expressed in cm/sec and is calculated by multiplying the mean velocity of all pixels divided by the area of the ROI. Three videos of 3 seconds each were obtained of the ROI, in the coronal plane, and used to calculate the CPI. Data are presented as mean ± SEM or median (quartiles). A total of 28 infants were included in this study: 16 male, 12 female. HUS was performed within the first 48 hours of therapeutic hypothermia treatment. CPI values were significantly higher in the seven non-survivors when compared to survivors (0.226±0.221 vs . 0.111±0.082 cm/sec; P=0.02). Increased perfusion intensity of the basal ganglia area within the first 48 of therapeutic hypothermia treatment was associated with poor outcome in neonates with HIE.

  13. Spectral color Doppler in the diagnosis and follow-up of Graves' disease

    International Nuclear Information System (INIS)

    Sponza, Massimo; Bertolotto, Michele; Ricci, Claudio; Fabris, Bruno; Armini, Lorenzo

    1997-01-01

    Hyperthyroidism in Graves' disease is caused by the presence of circulating autoantibodies to the THS receptors on the thyroid cells. Thyroid-suppression therapy prevents hormone production directly, without affecting the pathogenetic process. They performed color Doppler US of the thyroid gland and pulsed Doppler analysis of thyroid artery flow in 21 patients with Graves' disease before and during medical treatment. US results were compared with those of a control group of 40 healthy subjects and correlated with the values of thyroid hormones, TSH and thyroid microsomal and thyroglobulin antibodies. The thyroid gland was hypo vascularized in the control group. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity of PSV 20 ± 4 cm/s, diastolic velocity of 8 ± 1 cm/s, and resistive index of 0.60 ± 0.04. The thyroid gland of Graves' disease patients was hyper vascularized. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity (PSV = 51 ± 12 cm/s), end diastolic velocity (VD = 15 ± 4 cm/s) and resistive index (RI = 0.71 ± 0.04) significantly higher than in normal subjects (p < 0.001). Circulating thyroid hormones and flow parameters normalized after 6-8 months of medical therapy (PSV = 20 ± 6 cm/s, VD = 9 ± 3 cm(s, RI = 0.58 ± 0.07). The color Doppler patterns normalized only in a patient with normal TSH and antibodies. Sampling of the thyroid arteries proved more repeatable than sampling of parenchymal vessels

  14. Doppler time-of-flight imaging

    KAUST Repository

    Heide, Felix

    2015-07-30

    Over the last few years, depth cameras have become increasingly popular for a range of applications, including human-computer interaction and gaming, augmented reality, machine vision, and medical imaging. Many of the commercially-available devices use the time-of-flight principle, where active illumination is temporally coded and analyzed on the camera to estimate a per-pixel depth map of the scene. In this paper, we propose a fundamentally new imaging modality for all time-of-flight (ToF) cameras: per-pixel velocity measurement. The proposed technique exploits the Doppler effect of objects in motion, which shifts the temporal frequency of the illumination before it reaches the camera. Using carefully coded illumination and modulation frequencies of the ToF camera, object velocities directly map to measured pixel intensities. We show that a slight modification of our imaging system allows for color, depth, and velocity information to be captured simultaneously. Combining the optical flow computed on the RGB frames with the measured metric axial velocity allows us to further estimate the full 3D metric velocity field of the scene. We believe that the proposed technique has applications in many computer graphics and vision problems, for example motion tracking, segmentation, recognition, and motion deblurring.

  15. Role of color Doppler ultrasound in the diagnosis of nonpalpable ...

    African Journals Online (AJOL)

    excluded from the study. Color Doppler was performed in all cases, followed by laparoscopy. Further, findings on laparoscopy were compared with those of CDUS. A 95% confidence interval for the sensitivity of CDUS was estimated considering a positive result on CDUS as the binomial variable. Results. Out of 25 patients, ...

  16. COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    Dominique Lafon

    2011-05-01

    Full Text Available The goal of this article is to present specific capabilities and limitations of the use of color digital images in a characterization process. The whole process is investigated, from the acquisition of digital color images to the analysis of the information relevant to various applications in the field of material characterization. A digital color image can be considered as a matrix of pixels with values expressed in a vector-space (commonly 3 dimensional space whose specificity, compared to grey-scale images, is to ensure a coding and a representation of the output image (visualisation printing that fits the human visual reality. In a characterization process, it is interesting to regard color image attnbutes as a set of visual aspect measurements on a material surface. Color measurement systems (spectrocolorimeters, colorimeters and radiometers and cameras use the same type of light detectors: most of them use Charge Coupled Devices sensors. The difference between the two types of color data acquisition systems is that color measurement systems provide a global information of the observed surface (average aspect of the surface: the color texture is not taken into account. Thus, it seems interesting to use imaging systems as measuring instruments for the quantitative characterization of the color texture.

  17. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  18. Acute scrotal pathology in Schonlein-Henoch purpura: management by color Doppler ultrasound. A case report

    International Nuclear Information System (INIS)

    Jornet, J.; Cervera, J.; Marco, S.F.; Gonzalez, M.

    1998-01-01

    Schonlein-Henoch purpura is the most common form of purpura in children. It can affect a number of organs, but scrotal involvement is rare. We present a case of scrotal hemorrhage and epidymo-orchitis, diagnosed by color Doppler ultrasound, in which conservative treatment was employed. The differential diagnosis involves testicular torsion, which is also, although less frequently, associated with Schonlein-Henoch purpura. color Doppler ultrasound results in the correct diagnosis, ruling out testicular torsion and avoiding surgical exploration of the testicles. (Author) 8 refs

  19. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-10-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment.

  20. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    International Nuclear Information System (INIS)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-01-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment

  1. Quantitation of stress echocardiography by tissue Doppler and strain rate imaging: a dream come true?

    Science.gov (United States)

    Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola

    2005-01-01

    Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

  2. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  3. Digital color imaging

    CERN Document Server

    Fernandez-Maloigne, Christine; Macaire, Ludovic

    2013-01-01

    This collective work identifies the latest developments in the field of the automatic processing and analysis of digital color images.For researchers and students, it represents a critical state of the art on the scientific issues raised by the various steps constituting the chain of color image processing.It covers a wide range of topics related to computational color imaging, including color filtering and segmentation, color texture characterization, color invariant for object recognition, color and motion analysis, as well as color image and video indexing and retrieval. <

  4. A rare case of OEIS complex –newer approach to diagnosis of exstrophy bladder by color doppler and its differentiation from simple omphalocele

    Directory of Open Access Journals (Sweden)

    Kavita Aneja

    2017-01-01

    Full Text Available The objective of this article is to present a new approach to diagnose and differentiate similar ventral masses by color Doppler. Two cases of ventral masses, a rare case of OEIS complex (Omphalocele-exstrophy-imperforate anus-spinal defects with unusual presentation of exstrophy bladder and another of simple omphalocele, were studied by color Doppler for diagnosis and differentiation between the nature of similar masses. Ventral mass with absent bladder, normal kidneys, and normal amniotic fluid index raised the suspicion of exstrophy bladder. Color Doppler depicting altered intrafetal course of umbilical arteries and umbilical arteries coursing along the sides of ventral mass substantiated the diagnosis. The spatial relation between umbilical artery and aorta (which has no mention in the current literature in sagittal view has been identified as an acute angle in a normal fetus and coined as “K angle” arbitrarily by the author. Color Doppler reveals altered (widened “K angle” in exstrophy bladder compared to normal fetuses. Other combined anomalies pointed to the diagnosis of OEIS complex. The second case of simple omphalocele depicts normal intrafetal course of umbilical arteries and normal acute umbilical artery–aorta angle (K angle on color Doppler. Color Doppler aids the early diagnosis of ventral defects. New method by umbilical artery-aorta angle (K angle assessment on color Doppler helps differentiate exstrophy bladder from omphalocele.

  5. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  6. Prognostic Value of Cardiac Time Intervals by Tissue Doppler Imaging M-Mode in Patients With Acute ST-Segment-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Søgaard, Peter

    2013-01-01

    Background- Color tissue Doppler imaging M-mode through the mitral leaflet is an easy and precise method to estimate all cardiac time intervals from 1 cardiac cycle and thereby obtain the myocardial performance index (MPI). However, the prognostic value of the cardiac time intervals and the MPI...... assessed by color tissue Doppler imaging M-mode through the mitral leaflet in patients with ST-segment-elevation myocardial infarction (MI) is unknown. Methods and Results- In total, 391 patients were admitted with an ST-segment-elevation MI, treated with primary percutaneous coronary intervention...

  7. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients; Utilidad del Doppler color y pulsado en la valoracion de los shunts portosistemicos quirurgicos en la edad pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I. [Hospital Universitario La Paz. Madrid (Spain)

    2003-07-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs.

  8. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  9. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  10. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients

    International Nuclear Information System (INIS)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I.

    2003-01-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs

  11. Spectral color Doppler in the diagnosis and follow-up of Graves` disease; Ruolo dell`eco color Doppler e dell`analisi flussimetrica nella diagnosi e nel follow-up della malattia dei Graves

    Energy Technology Data Exchange (ETDEWEB)

    Sponza, Massimo; Bertolotto, Michele; Ricci, Claudio [Ospedale di Cattinara, Trieste (Italy). Istituto di Medicina Clinica; Fabris, Bruno; Armini, Lorenzo [Ospedale di Cattinara, Trieste (Italy). Istituto di Radiologia

    1997-04-01

    Hyperthyroidism in Graves` disease is caused by the presence of circulating autoantibodies to the THS receptors on the thyroid cells. Thyroid-suppression therapy prevents hormone production directly, without affecting the pathogenetic process. They performed color Doppler US of the thyroid gland and pulsed Doppler analysis of thyroid artery flow in 21 patients with Graves` disease before and during medical treatment. US results were compared with those of a control group of 40 healthy subjects and correlated with the values of thyroid hormones, TSH and thyroid microsomal and thyroglobulin antibodies. The thyroid gland was hypo vascularized in the control group. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity of PSV 20 {+-} 4 cm/s, diastolic velocity of 8 {+-} 1 cm/s, and resistive index of 0.60 {+-} 0.04. The thyroid gland of Graves` disease patients was hyper vascularized. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity (PSV = 51 {+-} 12 cm/s), end diastolic velocity (VD = 15 {+-} 4 cm/s) and resistive index (RI = 0.71 {+-} 0.04) significantly higher than in normal subjects (p < 0.001). Circulating thyroid hormones and flow parameters normalized after 6-8 months of medical therapy (PSV = 20 {+-} 6 cm/s, VD = 9 {+-} 3 cm/s, RI = 0.58 {+-} 0.07). The color Doppler patterns normalized only in a patient with normal TSH and antibodies. Sampling of the thyroid arteries proved more repeatable than sampling of parenchymal vessels.

  12. Pulsed and Color Doppler Sonographic Findings of Penile Mondor' Disease

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hye Yeon; Chung, Dong Jin; Kim, Kum Won; Hwang, Cheol Mog [University of Konyang School of Medicine, Daejeon (Korea, Republic of)

    2008-04-15

    Penile Mondor's disease is a rare disease that's characterized by thrombosis in the dorsal vein of the penis. Doppler ultrasonography (US) clearly visualizes dorsal vein thrombosis and the associated hemodynamic alterations. Previous studies have demonstrated the typical color Doppler US findings of superficial dorsal vein thrombosis without the flow signals in this area, yet this is insufficient to understand the hemodynamics in penile Mondor's disease. We report here for the first time a cavernosal artery flow signal pattern in a penile Mondor's disease patient, in addition to its previously reported classic US findings. In conclusion, the Doppler US findings of thrombus without blood flow in the superficial dorsal vein and the low-flow, high resistance in the cavernosal artery may be suggestive of penile Mondor's disease.

  13. Cow's milk allergy: color Doppler ultrasound findings in infants with hematochezia.

    Science.gov (United States)

    Epifanio, Matias; Spolidoro, Jose Vicente; Missima, Nathalia Guarienti; Soder, Ricardo Bernardi; Garcia, Pedro Celiny Ramos; Baldisserotto, Matteo

    2013-01-01

    ultrasound (US) has been an important diagnostic tool to identify several causes of gastrointestinal bleeding. Infants with cow's milk allergy (CMA) may present hematochezia and the confirmation of the diagnosis can be difficult. The aim of this study is to describe grayscale and color Doppler ultrasound findings in patients with CMA. we retrospectively studied 13 infants with CMA. All infants presented severe hematochezia and abdominal pain. All underwent an US study with the diagnosis of allergic colitis. This diagnosis was based on clinical findings, recovery after infant or mother exclusion diets in the case of exclusive breastfeeding and positive oral challenge test. the mean age ranged from 1 to 6 months (mean=3.53). Seven out of 13 infants (53.8%) had grayscale and color Doppler sonographic repeated after exclusion diet. Twelve out of 13 (92,3%) showed abnormalities at US and CDUS at beginning. The positive findings suggesting colitis were thickened bowel walls and increased vascularity, especially in the descending and sigmoid colon. Colonoscopy and histopathological findings were compatible with allergic colitis. After a diet change the 13 infants recovered and their oral challenge tests were positive. Doppler US may be very useful in diagnosing secondary colitis, such as CMA, and to exclude several other abdominal diseases that can emulate this disease. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  14. Endoscopic Color Doppler Ultrasonographic Evaluation of GastricVarices Secondary to Left-Sided Portal Hypertension

    Science.gov (United States)

    Sato, Takahiro; Yamazaki, Katsu; Kimura, Mutsuumi; Toyota, Jouji; Karino, Yoshiyasu

    2014-01-01

    Gastric varices that arise secondary to the splenic vein occlusion can result in gastrointestinal hemorrhaging. Endoscopic color Doppler ultrasonography (ECDUS) was performed in 16 patients with gastric varices secondary to splenic vein occlusion. This study retrospectively evaluated the role of ECDUS in the diagnosis of gastric varices secondary to splenic vein occlusion. Thirteen patients had co-existing pancreatic diseases: 8 with chronic pancreatitis, 4 with cancer of the pancreatic body or tail and 1 with severe acute pancreatitis. Of the remaining 3 patients, 1 had myeloproliferative disease, 1 had advanced gastric cancer, and the third had splenic vein occlusion due to an obscure cause. The endoscopic findings of gastric varices were: variceal form (F) classified as enlarged tortuous (F2) in 12 cases and large, coil-shaped (F3) in 4 cases, and positive for erosion or red color sign of the variceal surface in 4 cases and negative in 12 cases. ECDUS color flow images of gastric variceal flow clearly depicted a round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body in all 16 cases. The velocities of F3 type gastric varices were significantly higher than those of the F2 type. The wall thickness of varices positive for erosion or red color sign was significantly less than the negative cases. I conclude that ECDUS color flow images of gastric variceal flow depicted specific findings of gastric varices secondary to splenic vein occlusion at the round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body. PMID:26852679

  15. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  16. Color Doppler US of normal cerebral venous sinuses in neonates: a comparison with MR venography

    International Nuclear Information System (INIS)

    Miller, Elka; Daneman, Alan; Doria, Andrea S.; Blaser, Susan; Traubici, Jeffrey; Jarrin, Jose; Shroff, Manohar; Moineddin, Rahim; Moore, Aideen

    2012-01-01

    Color Doppler US (CDUS) has been used for evaluation of cerebral venous sinuses in neonates. However, there is very limited information available regarding the appearance of superficial and deep normal cerebral venous sinuses using CDUS and the specificity of the technique to rule out disease. To determine the specificity, inter-modality and inter-reader agreement of color Doppler US (CDUS). To evaluate normal cerebral venous sinuses in neonates in comparison to MR venography (MRV). Newborns undergoing a clinically indicated brain MRI were prospectively evaluated. All underwent a dedicated CDUS of the cerebral venous sinuses within 10 h (mean, 3.5 h, range, and 2-7.6 h) of the MRI study using a standard protocol. Fifty consecutive neonates participated in the study (30 males [60%]; 25-41 weeks old; mean, 37 weeks). The mean time interval between the date of birth and the CDUS study was 19.1 days. No cases showed evidence of thrombosis. Overall agreement for US reading was 97% (range, 82-100%), for MRV reading, 99% (range, 96-100%) and for intermodality, 100% (range, 96-100%). Excellent US-MRI agreement was noted for superior sagittal sinus, cerebral veins, straight sinus, torcular Herophili, sigmoid sinus, superior jugular veins (94-98%) and transverse sinuses (82-86%). In 10 cases (20%), MRV showed flow gaps whereas normal flow was demonstrated with US. Visualization of the inferior sagittal sinus was limited with both imaging techniques. Excellent reading agreement was noted for US, MRV and intermodality. CDUS is highly specific to rule out cerebral venous thrombosis in neonates and holds potential for clinical application as part of clinical-laboratory-imaging algorithms of pre/post-test probabilities of disease. (orig.)

  17. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  18. Choroid metastasis of papillary thyroid carcinoma. Color doppler ultrasound study

    International Nuclear Information System (INIS)

    Ganado, T.; Torre, S. de la; Contreras, E.; Hernandez, J.

    1997-01-01

    The most common causes of intraocular metastases are breast and lung cancers, although many other neoplasms can metastasize to the eye. Most of the metastases are located in the posterior pole and the choroid is more often involved than the retina. We present a case of a choroidal metastasis from a papillary carcinoma of the thyroid, associated with a massive subretinal hemorrhage. Findings with color Doppler ultrasound are emphasized. (Author) 9 refs

  19. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  20. Tumor vascularity evaluated by transrectal color Doppler US in predicting therapy outcome for low-lying rectal cancer

    International Nuclear Information System (INIS)

    Barbaro, Brunella; Valentini, Vincenzo; Coco, Claudio; Mancini, Anna Paola; Gambacorta, Maria Antonietta; Vecchio, Fabio Maria; Bonomo, Lorenzo

    2005-01-01

    Purpose: To evaluate the impact on T downstaging of the vasculature supplying blood flow to rectal cancer evaluated by color Doppler ultrasound. Methods and Materials: Color Doppler images were graded in 29 T3-staged rectal carcinoma patients sonographically just before chemoradiation. Any arterial vessels detected in rectal masses were assigned one of two grades: vascularity was considered as grade 1 for vessels feeding the periphery and as grade 2 for vessels coursing in all rectal masses within its peripheral and central portions. The pulsatility indices (PI = peak systolic velocity - end-diastolic velocity/time-averaged maximum velocity) were calculated in the central and peripheral portions. Results: The pathologic observations showed a change in stage in 15 of the 23 patients graded 2, positive predictive value 65.2% (p = 0.047), and in one of the six rectal cancers graded 1 (negative predictive value, 83.3%). The minimal peripheral PI values in rectal cancer graded 2 were higher in nonresponding (2.2 ± 1.3) than in responding lesions (1.6 ± 0.7) p = 0.01. Conclusion: Vascularity graded 2 associated with low peripheral PI values are indicators of therapy outcome. Vascularity graded 1 and high peripheral PI values in graded 2 have negative predictive value

  1. The Diagnostic Value of Transvaginal Sonograph (TVS), Color Doppler, and Serum Tumor Marker CA125, CEA, and AFP in Ovarian Cancer.

    Science.gov (United States)

    Zhang, Fang; Zhang, Zhou-Long

    2015-06-01

    The purpose of this study is to investigate the diagnostic value of transvaginal sonograph (TVS), color Doppler, and serum tumor marker CA125, CEA, and AFP in ovarian cancer. From June, 2011 to May, 2013, 102 cases with adnexal mass were recruited in this study (32 cases of malignant ovarian cancer and 70 cases of benign ovarian tumor according to pathological diagnosis). TVS, color Doppler, and serum tumor markers were used for tumor diagnosis. The sensitivity, specifity, positive prediction, negative prediction, and Youden's index were analyzed. Of the 102 patients, 32 were diagnosed with malignant ovarian cancer and 70 were diagnosed with benign ovarian tumor according to pathological diagnosis. Based on TVS results, 37 cases were malignant while 65 cases were benign. Based on color Doppler results, 34 cases were malignant while 68 cases were benign. Based on TVS and color Doppler results, 35 cases were malignant while 65 were benign. Based on CA125 test results, 34 cases were malignant while 68 cases were benign. Based on CEA test results, 8 cases were malignant and 94 cases were benign. Bases on AFP test results, 9 cases were malignant while 93 cases were benign. Based on the results of combination tumor marker test, 38 cases were malignant while 64 cases were benign. The combination of TVS, color Doppler, and tumor marker test showed optimal diagnostic value with a sensitivity of 90.63 %, specificity of 97.14 %, positive prediction of 93.94 %, negative prediction of 98.55 %, and Youden's index of 94.02 %. The combination of TVS, color Doppler, and tumor marker test is of great diagnostic value, which should be widely used in clinical practice.

  2. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  3. Usefulness of the myocardial performance index determined by tissue Doppler imaging m-mode for predicting mortality in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Haahr-Pedersen, Sune Ammentorp

    2011-01-01

    The objective of this study was to evaluate the prognostic value of the myocardial performance index (MPI), assessed by color-coded tissue Doppler imaging (TDI) M-mode through the anterior mitral leaflet. Color TDI M-mode through the mitral leaflet is an easy, very fast, and precise method...... ventricular in- and outflow using standard procedures (MPI(conv)) and by color-coded TDI M-mode through the mitral leaflet in the apical 4-chamber view (MPI(TDI)). MPI(TDI) was increased in subjects with coronary heart disease (CHD) compared to controls, even after multivariable adjustment (p

  4. Role of color Doppler US in the evaluation of uterine leiomyoma treated with gonadotrophin-releasing hormone (GnRH) agonist (Zoladex)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Sik; Sohn, Cheol Ho; Lee, Tae Sung [Keimyung University Dongsan Medical Center, Taegu (Korea, Republic of)

    1999-03-15

    To access the role of color Doppler US in the evaluation of uterine leiomyoma treated with GnRH agonist (Zoladex). Out of 25 patients with uterine leiomyoma treated with Zoladex, nineteen cases of leiomyoma in 18 women who had US examination before and after medication were included in this study. Zoladex was injected subcutaneously three times within three months. Both gray scale and color Doppler US were obtained before and 1-3 months after the medication. The size, volume, location and internal echoes of the leiomyoma were recorded with gray scale US. Changes in the amount of color signal within leiomyomas were recorded. Pulsatility index (PI), resistive index (RI), peak systolic velocity (PSV) of both uterine artery and arteries within leiomyomas were also recorded. The image findings of good response group and poor response group in which the volume reduction of the leiomyoma was above or below 50% respectively were compared with each other. The reduction of the volume of leiomyoma was compared between a group with decrease in the amount of color signals during follow-up US and a group with increase or no change. Mean reduction of the volume of leiomyomas was 52%. Changes in the amount of color signals of the leiomyoma, PI, RI, PSV obtained from the arteries within leiomyomas were not correlated with the change of the volume of leiomyomas. PSV of uterine artery in one month follow-up and PI of two month follow-up were correlated with the changes of the volume of leiomyomas (p<0.05). RI of uterine artery in two month follow-up was useful in prediction of the good response group and the poor response group (p<0.05). The prediction of the volume reduction of leiomyoma following Zoladex medication might be possible by obtaining RI of uterine artery in two month follow-up. Doppler US of the arteries within the leiomyoma was not useful.

  5. Role of color Doppler US in the evaluation of uterine leiomyoma treated with gonadotrophin-releasing hormone (GnRH) agonist (Zoladex)

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Sohn, Cheol Ho; Lee, Tae Sung

    1999-01-01

    To access the role of color Doppler US in the evaluation of uterine leiomyoma treated with GnRH agonist (Zoladex). Out of 25 patients with uterine leiomyoma treated with Zoladex, nineteen cases of leiomyoma in 18 women who had US examination before and after medication were included in this study. Zoladex was injected subcutaneously three times within three months. Both gray scale and color Doppler US were obtained before and 1-3 months after the medication. The size, volume, location and internal echoes of the leiomyoma were recorded with gray scale US. Changes in the amount of color signal within leiomyomas were recorded. Pulsatility index (PI), resistive index (RI), peak systolic velocity (PSV) of both uterine artery and arteries within leiomyomas were also recorded. The image findings of good response group and poor response group in which the volume reduction of the leiomyoma was above or below 50% respectively were compared with each other. The reduction of the volume of leiomyoma was compared between a group with decrease in the amount of color signals during follow-up US and a group with increase or no change. Mean reduction of the volume of leiomyomas was 52%. Changes in the amount of color signals of the leiomyoma, PI, RI, PSV obtained from the arteries within leiomyomas were not correlated with the change of the volume of leiomyomas. PSV of uterine artery in one month follow-up and PI of two month follow-up were correlated with the changes of the volume of leiomyomas (p<0.05). RI of uterine artery in two month follow-up was useful in prediction of the good response group and the poor response group (p<0.05). The prediction of the volume reduction of leiomyoma following Zoladex medication might be possible by obtaining RI of uterine artery in two month follow-up. Doppler US of the arteries within the leiomyoma was not useful.

  6. Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee Model

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Shin, Myung Jin; Kim, Seong Moon; Kim, Namkug; Suh, Sang Hyun; Suh, Jin Suck

    2008-01-01

    To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings. Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment. The mean area of color pixels in PD US changed from 4.37 to 16.42 mm 2 in the arthritic knee after enhancement (p 2 in the control knee (p 0.05). Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees

  7. Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

    Directory of Open Access Journals (Sweden)

    Elzivânia G. Silva

    Full Text Available ABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1, anterior chamber depth (M2, lens thickness (M3, lens length (M4, vitreous chamber depth (M5, optical disc length (M6 and optic nerve diameter (M7. Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS, final diastolic velocity (VDF, resistivity index (IR and pulse index (IP. No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05. The vitreous chamber depth (M5 was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05. The mean resistivity index (RI showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities

  8. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T.

    Science.gov (United States)

    Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares

    2018-02-01

    We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.

  9. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... include signal analysis and display equipment, patient and equipment supports, component parts, and...

  10. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    2016-01-01

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  11. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  12. TORSION TESTIS : ROLE OF COLOR DOPPLER : A STUDY OF 50 CASES

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND: T orsion testis is one of the catast r ophic conditions in children and young a d u lts. Traditionally the diagnosis was made clinical presentation and suspicion. Critical decision making is essential to save the testis . OBJECTIVE: To study the usefu lness and efficacy of Doppler ultrasound in correctly diagnosing acute scrotal conditions in children and young adults to save the testis and to avoid negative explorations. METHODS: Over a period of two years 50 patients with acute scrotum were admitted i n general surgery department who underwent Doppler ultrasound scrotum and its efficacy in correctly diagnosing the pathology was analysed. RESULTS: 50 patients with age group <25 years were included in study. Scrotal pain was the most frequent presenting s ymptom of acute scrotum (98% followed by Swelling of the hemiscrolum on the involved side present in 86% of the patients. Doppler ultrasound showed torsion of testis in 18 patients. On Scrotal exploration, torsion of spermatic cord was confirmed in 16 pat ients, one patient had torsion of appendix of testis and the other had Epididymo - orchitis. Thus the sensitivity and specificity of Doppler ultrasonography for testicular torsion was 86.9% and 92.6% respectively. 2 patients with equivocal Doppler findings, but strong clinical suspicion of testicular torsion were explored, and testis was found to be torsed in both two patients. Doppler ultrasonography showed Epididymo - orchitis in 22 patients, torsion of testicular appendage in 2 patients, Idiopathic scrotal edema in one, and in 5 pts no significant pathology found. All twenty patients of epididymo - orchitis, two patients of torsion of testicular appendage, and one patient of idiopathic scrotal edema were managed conservatively. At three weeks follow up, all th e patients were free of symptoms. The sensitivity and specificity of Doppler ultrasonography for epididymo - orchitis was 95% and 100% respectively. CONCLUSIONS: color

  13. Absence of Doppler signal in transcranial color-coded ultrasonography may be confirmatory for brain death: A case report

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-08-01

    Full Text Available Transcranial Doppler ultrasonography (TCD is a valuable tool for demonstrating cerebral circulatory arrest (CCA in the setting of brain death. Complete reversal of diastolic flow (to-and-fro flow and systolic spikes in bilateral terminal internal carotid arteries and vertebrobasilar circulation are considered as specific sonogram configurations supporting the diagnosis of CCA. Because of the possibility of sonic bone window impermeability, absence of any waveform in TCD is not confirmatory for CCA unless there is documentation of disappearance of a previously well detected signal by the same recording settings. Transcranial color-coded sonography (TCCS with B-mode imaging can reliably detect adequacy of bone windows with clarity contralateral skull and ipsilateral planum temporale visualization. Therefore, absence of detectable intracranial Doppler signal along with available ultrasound window in TCCS can confirm clinical diagnosis of brain death. We herein discuss this entity from the frame of a representative case.

  14. Embedding Color Watermarks in Color Images

    Directory of Open Access Journals (Sweden)

    Wu Tung-Lin

    2003-01-01

    Full Text Available Robust watermarking with oblivious detection is essential to practical copyright protection of digital images. Effective exploitation of the characteristics of human visual perception to color stimuli helps to develop the watermarking scheme that fills the requirement. In this paper, an oblivious watermarking scheme that embeds color watermarks in color images is proposed. Through color gamut analysis and quantizer design, color watermarks are embedded by modifying quantization indices of color pixels without resulting in perceivable distortion. Only a small amount of information including the specification of color gamut, quantizer stepsize, and color tables is required to extract the watermark. Experimental results show that the proposed watermarking scheme is computationally simple and quite robust in face of various attacks such as cropping, low-pass filtering, white-noise addition, scaling, and JPEG compression with high compression ratios.

  15. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis

    Directory of Open Access Journals (Sweden)

    Nádia Martins

    2016-04-01

    Full Text Available Giant Cell Arteritis (GCA is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  16. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis.

    Science.gov (United States)

    Martins, N; Polido-Pereira, J; Rodrigues, A M; Soares, F; Batista, P; Pereira da Silva, J A

    2016-01-01

    Giant Cell Arteritis (GCA) is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS) is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  17. Twinkling artifact on color Doppler ultrasound: an advantage or a pitfall?

    Science.gov (United States)

    Ozan, Ebru; Atac, Gokce Kaan; Gundogdu, Sadi

    2016-07-01

    The twinkling artifact (TA) or color comet-tail artifact is characterized by a rapidly changing mixture of red and blue color Doppler signals. Even though many diseases and clinical conditions have been shown to produce this artifact, its source is not clearly understood yet. The TA may provide additional information to gray-scale ultrasound findings in several clinical situations. However, there may be pitfalls to keep in mind. We must first be aware of the TA to benefit from the advantages and avoid the pitfalls. In this review, we aim to give practicing radiologists an overview of the mechanisms and clinical applications of the TA by illustrating sample cases we have encountered.

  18. [Ultrasound and color Doppler applications in nephrology. The normal kidney: anatomy, vessels and congenital anomalies].

    Science.gov (United States)

    Meola, Mario; Petrucci, Ilaria; Giovannini, Lisa; Samoni, Sara; Dellafiore, Carolina

    2012-01-01

    Gray-scale ultrasound is the diagnostic technique of choice in patients with suspected or known renal disease. Knowledge of the normal and abnormal sonographic morphology of the kidney and urinary tract is essential for a successful diagnosis. Conventional sonography must always be complemented by Doppler sampling of the principal arterial and venous vessels. B-mode scanning is performed with the patient in supine, prone or side position. The kidney can be imaged by the anterior, lateral or posterior approach using coronal, transverse and oblique scanning planes. Morphological parameters that must be evaluated are the coronal diameter, the parenchymal thickness and echogenicity, the structure and state of the urinary tract, and the presence of congenital anomalies that may mimic a pseudomass. The main renal artery and the hilar-intraparenchymal branches of the arterial and venous vessels should be accurately evaluated using color Doppler. Measurement of intraparenchymal resistance indices (IP, IR) provides an indirect and quantitative parameter of the stiffness and eutrophic or dystrophic remodeling of the intrarenal microvasculature. These parameters differ depending on age, diabetic and hypertensive disease, chronic renal glomerular disease, and interstitial, vascular and obstructive nephropathy.

  19. Color Doppler ultrasound evaluation of asphyxial neonatal left ventricular function and its correlation with target organ damage

    Directory of Open Access Journals (Sweden)

    Cheng-Cai Chen

    2017-01-01

    Full Text Available Objective: To study the color Doppler ultrasound parameters of asphyxial neonatal left ventricular function and the correlation with target organ damage. Methods: Normal neonates, mildly asphyxial neonates and severely asphyxial neonates born in our hospital between January 2014 and December 2015 were selected as the control group (n = 46, mild asphyxia group (n = 37 and severe asphyxia group (n = 23 respectively. On the 1st day after birth, color Doppler ultrasound was used to evaluate left ventricular function, and serum was collected to determine myocardial tissue injury, brain tissue injury and brain tissue metabolism indexes. Results: Color Doppler ultrasound parameters cardiac output (CO, ejection fraction (EF and left ventricular fraction shortening (FS as well as serum folate and vitamin B12 content of mild asphyxia group and severe asphyxia group were significantly lower than those of control group (P<0.05 while serum creatine kinase isoenzyme (CK-MB, troponin I (cTnI, troponin T (cTnT, S100B, neuron-specific enolase (NSE, creatine kinase BB (CK-BB, glycogen phosphorylase BB (GPBB, and homocysteine (Hcy content were significantly higher than those of control group (P<0.05; CO, FS and EF as well as serum folate and vitamin B12 content of severe asphyxia group were significantly lower than those of mild asphyxia group (P<0.05 while serum CK-MB, cTnT, cTnI, S100B, NSE, CK-BB, GPBB and Hcy content were significantly higher than those of mild asphyxia group (P<0.05. Conclusions: Color Doppler ultrasound can accurately assess asphyxial neonatal left ventricular function damage degree and is closely related to myocardial tissue injury and brain tissue injury degree.

  20. Value of downstream circulation in renal artery stenosis with arterial hypertension: comparison between color Doppler flow and digital renal angiography in 123 patients

    International Nuclear Information System (INIS)

    Grataloup, C.; Challande, P.; Plainfosse, M.C.; Girerd, X.; Belattar, K.; Plouin, P.F.

    1996-01-01

    Digital renal angiography and color Doppler flow were compared for diagnosis of renal artery stenosis in 123 hypertensive patients with a prevalence of renal artery stenosis ≥75% of 21 %. Only color Doppler flow signs found downstream from the stenosis could be quantified. A rising time (RT) >0.07 s was the best marker for renal artery stenosis ≥ 75 % according to a receiver operating characteristic curve with a specificity of 97 %, a sensitivity of 88 %, a positive predictive value of 86 %, a negative predictive value of 98 % and an accuracy of 96 %. Digital renal angiography and color Doppler flow findings for renal artery lesions were classified into 4 degrees with agreement for 86 % of the kidneys. (authors). 13 refs., 5 figs., 8 tabs

  1. [Usefulness of transvaginal Doppler color in ovarian neoplasms diagnosis].

    Science.gov (United States)

    Muñoz, H; Martínez, L; Parra, M; Cunill, E; Polanco, M; Leible, S; Romero, C

    1993-01-01

    The vascular resistant evaluation by Doppler waveform is a method used in clinic and research. The neoplastic malignant has an increased growth with an increased amount of neomalignant vessels. The presence of these vessels produce an increase of the transversal section area from the tumoral vascular system, therefore there is a decrease in the vascular resistance. The main objective of this work is to show the usefulness of Doppler waveform as predictor factor of malignity in ovary tumors. Eighteen patients with tumoral mass in the ovary were studied. They were between 21 and 67 years old (mean = 43). The tumoral volume and the flow resistance of blood vessels which irrigated those tumoral mass were evaluated by transvaginal ultrasound with color and pulsed Doppler. The pulsatility index (SD/media) was used. The Chi cuadrado test was used to evaluate the results. The results show the presence of six malignant tumors, three of them with low malignicity and the presence of twelve benign tumors. The age of the patients between both groups (malignant and benign tumors) were significant different (40.7 versus 52 years old, p < 0.001). The mean tumoral volume was 65 ml, with a range of 17 to 225 ml in the group of patients with benign tumors and the mean tumoral volume from patients with malignant tumors was 951 ml with a range of 141 to 3142 ml. The difference in the tumoral in both groups was significative with p < 0.001.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Does color Doppler sonography improve the clinical assessment of patients with acute scrotum?

    International Nuclear Information System (INIS)

    Pepe, Pietro; Panella, Paolo; Pennisi, Michele; Aragona, Francesco

    2006-01-01

    albuginea was present in six out of seven patients submitted to surgical exploration for previous blunt trauma and the sonographic diagnosis of hematocele was documented in all cases. The single false-negative diagnosis of testicular torsion in CDS occurred in an 18-month-old child. In presence of funicular torsion, the sensitivity and specificity of physical exam and CDS were 100% versus 95.7% and 86.5% versus 85.3%, respectively; sensitivity and specificity of SPV, TDV and color-Doppler signal on the testis were 100% and 94.8% versus 100% and 90.1% versus 95.7% and 90.8%. In the pre-operative assessment of scrotal trauma, the B-mode US showed a sensitivity and specificity of 100% and 90%, respectively; the color Doppler analysis has not supplied with additional elements for planning a surgical exploration. In presence of orchiepididymitis, the sensitivity and specificity of the physical exam in association to CDS was equal to 100%. In all patients with torsion of the testicular appendix, physical exam and CDS parameters were within normal limits. Discussion and conclusions: In our experience CDS is an indispensable imaging modality for the clinical assessment of patients with acute scrotum; however, the informations it can afford are operator-dependent and have to be supported by the history and physical exam of the patient. CDS findings constitute probably an important medico-legal support when the necessity of surgical exploration is excluded; anyway, in presence of a clinical suspicion of testicular torsion, even with an apparently normal CDS, the surgical exploration is recommended

  3. Diagnosis of right-sided varicocele: A retrospective comparative study between clinical examination, Doppler findings, US imaging and vascular anatomy at phlebography

    International Nuclear Information System (INIS)

    Cariati, Maurizio; Pieri, Stefano; Agresti, Paolo; Cariati, Massimiliano; Candito, Davide Fabio; Damiani, Giovanni; Marzano, Domenico

    2012-01-01

    Historically varicocele is diagnosed almost exclusively on the left side. The introduction of new imaging techniques has allowed the identification and characterization of right varicocele. This study aims to compare the diagnostic accuracy of various imaging techniques to data obtained using phlebography in the diagnosis of right varicocele. Patients treated for isolated right varicocele between 1992 and 2010 were retrospectively identified. Data from clinical examination, Doppler-USS, Color-Doppler-USS and Retrograde Phlebography were collected for each patient. 133 out of 4305 patients (3.1%) presented with an isolated right varicocele. 34 of these patients (25.6%) presented with palpable right varicocele. Doppler-USS identified various degrees of type I right venous reflux in 90 patients (67.7%). Phlebography showed venous reflux in all the patients (133), although with variability in terms of internal spermatic vein anatomy. Right varicocele is characterized by predictable anatomic features. Identification and characterization of these features is useful in guiding percutaneous treatment, allowing to optimize radiological display and reducing failure rate

  4. Diagnosis of right-sided varicocele: A retrospective comparative study between clinical examination, Doppler findings, US imaging and vascular anatomy at phlebography

    Energy Technology Data Exchange (ETDEWEB)

    Cariati, Maurizio, E-mail: davide.candito@libero.it [U.O.C. Radiologia, A.O. San Carlo Borromeo, via Pio II 3, 20153 Milan (Italy); Pieri, Stefano, E-mail: stefano.pieri@scamilloforlanini.rm.it [U.O.C. Diagnostica per Immagini Cardioscienze, A.O. San Camillo - Forlanini, Piazza Carlo Forlanini 1, 00151 Rome (Italy); Agresti, Paolo, E-mail: paolo.agresti@scamilloforlanini.rm.it [U.O.C. Diagnostica per Immagini Cardioscienze, A.O. San Camillo - Forlanini, Piazza Carlo Forlanini 1, 00151 Rome (Italy); Cariati, Massimiliano, E-mail: massimiliano.cariati@kcl.ac.uk [Department of Academic Oncology, King' s College London, 3rd Floor Bermondsey Wing, Guy' s Hospital, Great Maze Pond, London SE1 9RT (United Kingdom); Candito, Davide Fabio, E-mail: davide.candito@yahoo.it [Scuola di Specializzazione in Radiodiagnostica, Facoltà di Medicina e Chirurgia, Università degli studi di Milano, via Festa del Perdono 7, 20122 Milan (Italy); Damiani, Giovanni, E-mail: damiani_giovanni@libero.it [Scuola di Specializzazione in Radiodiagnostica, Facoltà di Medicina e Chirurgia, Università degli studi di Milano, via Festa del Perdono 7, 20122 Milan (Italy); Marzano, Domenico, E-mail: domenico.marzano@scamilloforlanini.rm.it [U.O.C. Urologia, A.O. San Camillo - Forlanini, Piazza Carlo Forlanini 1, 00151 Rome (Italy)

    2012-09-15

    Historically varicocele is diagnosed almost exclusively on the left side. The introduction of new imaging techniques has allowed the identification and characterization of right varicocele. This study aims to compare the diagnostic accuracy of various imaging techniques to data obtained using phlebography in the diagnosis of right varicocele. Patients treated for isolated right varicocele between 1992 and 2010 were retrospectively identified. Data from clinical examination, Doppler-USS, Color-Doppler-USS and Retrograde Phlebography were collected for each patient. 133 out of 4305 patients (3.1%) presented with an isolated right varicocele. 34 of these patients (25.6%) presented with palpable right varicocele. Doppler-USS identified various degrees of type I right venous reflux in 90 patients (67.7%). Phlebography showed venous reflux in all the patients (133), although with variability in terms of internal spermatic vein anatomy. Right varicocele is characterized by predictable anatomic features. Identification and characterization of these features is useful in guiding percutaneous treatment, allowing to optimize radiological display and reducing failure rate.

  5. Preload dependence of color M-mode Doppler flow propagation velocity in controls and in patients with left ventricular dysfunction

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Søndergaard, E

    2000-01-01

    The purpose of this study was to assess the effects of preload alterations on color M-mode flow propagation velocity (Vp) in volunteers with normal left ventricular (LV) function and in patients with depressed LV function. Color M-mode Doppler echocardiography was performed during Valsalva maneuv...

  6. A universal color image quality metric

    NARCIS (Netherlands)

    Toet, A.; Lucassen, M.P.

    2003-01-01

    We extend a recently introduced universal grayscale image quality index to a newly developed perceptually decorrelated color space. The resulting color image quality index quantifies the distortion of a processed color image relative to its original version. We evaluated the new color image quality

  7. A study of the distribution of color Doppler flows in the superficial digital flexor tendon of young Thoroughbreds during their training periods.

    Science.gov (United States)

    Hatazoe, Takashi; Endo, Yoshiro; Iwamoto, Yohei; Korosue, Kenji; Kuroda, Taisuke; Inoue, Saemi; Murata, Daiki; Hobo, Seiji; Misumi, Kazuhiro

    2015-01-01

    Aim of this study was to evaluate the relationships of exercise and tendon injury with Doppler flows appearing in the superficial digital flexor tendon (SDFT) of young Thoroughbreds during training periods. The forelimb SDFTs of 24 one- to two-year-old Thoroughbreds clinically free of any orthopaedic disorders were evaluated using grey-scale (GS) and color Doppler (CD) images during two training periods between December 2013 to April 2015. Twelve horses per year were examined in December, February, and April in training periods that began in September and ended in April. The SDFT was evaluated in 3 longitudinal images of equal lengths (labelled 1, 2, 3 in order from proximal to distal), and 6 transversal images separated by equal lengths (labelled 1A, 1B, 2A, 2B, 3A and 3B in order from proximal to distal) of the metacarpus using both GS and CD. The running (canter and gallop) distance for 1 month before the date of the ultrasonographic examinations was increased in December, February, and April in both of the two training periods. CD flows defined as rhythmically blinking or pulsatory colored signals were found in 56 of 864 (6.4%) transversal CD images, in 28, 12, 13, and 3 images of 1A, 1B, 2A and 2B, respectively, and in 7, 14, and 35 images captured in December, February, and April, respectively. There were no longitudinal or transversal GS images indicating injury in the SDFTs in either of the two training periods. The increase of CD flows in the proximal regions of the SDFT are possibly related to the increase of the running distance during the training periods of the one- to two-year-old Thoroughbreds. Because no injury was diagnosed in the SDFTs by GS images during the training periods, the increase of CD flows in the proximal parts of SDFT is not necessarily predictive of tendon injury in the near future during the training period of young Thoroughbreds.

  8. Association of maternal and umbilical cord blood leptin concentrations and abnormal color Doppler indices of umbilical artery with fetal growth restriction

    Directory of Open Access Journals (Sweden)

    Elahe Zareaan

    2017-08-01

    Full Text Available Background: Fetal growth restriction (FGR is a condition with heterogeneous pathophysiology which characterized by fetal weight less than the tenth percentile for gestational age. Several factors have impact on maternal, placental and fetal due to growth restriction. Objective: The aim of this study was to investigate the relationship between levels of leptin in the cord, and serum leptin of mothers also abnormal color Doppler indices of umbilical artery with fetal growth restriction. Materials and Methods: This is a cross sectional study conducted in Isfahan, Iran, 2015-2016. We recruited 40 women with singleton pregnancies complicated by fetal growth restriction (Group I and 40 pregnant women with normal fetal growth (Group II with matched age. Maternal serum and umbilical artery leptin levels were determined with Enzyme-Linked immunosorben method. Also, color Doppler ultrasound of umbilical artery was performed. Results: Mean maternal and fetal leptin levels were lower in the FGR group compared to the normal group (36.58±(20.99 and 7.42 ±(4.08vs. 47.32±(22.50 and 30.49±(14.50 respectively. Also, mean fetal leptin level was lower in the group with abnormal color Doppler sonographic indices compared to the normal group (7. 40 ±(4.10vs 27.06±(15.80, respectively. Conclusion: This study indicated that maternal and fetal leptin levels are correlated with FGR originating from damaged placental function; also fetal leptin level can indicate changes in color Doppler sonographic indices.

  9. A Study of Color Transformation on Website Images for the Color Blind

    OpenAIRE

    Siew-Li Ching; Maziani Sabudin

    2010-01-01

    In this paper, we study on color transformation method on website images for the color blind. The most common category of color blindness is red-green color blindness which is viewed as beige color. By transforming the colors of the images, the color blind can improve their color visibility. They can have a better view when browsing through the websites. To transform colors on the website images, we study on two algorithms which are the conversion techniques from RGB colo...

  10. Pulsed-wave tissue Doppler and color tissue Doppler echocardiography: calibration with M-mode, agreement, and reproducibility in a clinical setting

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Jons, Christian; Fritz-Hansen, Thomas

    2009-01-01

    BACKGROUND: Myocardial velocities can be measured with both pulsed-wave tissue Doppler (PWTD) and color tissue Doppler (CTD) echocardiography. We aimed to (A) to explore which of the two methods better approximates true tissue motion and (B) to examine the agreement and the reproducibility...... of the two methods in a routine clinical setting. METHODS: For Study A, the displacements of 63 basal myocardial segments from 13 patients were examined with M-mode and compared with the velocity-time integral of PWTD and CTD velocities. For Study B, the basal lateral segments from 58 patients were examined...... with PWTD and CTD, and the peak myocardial velocities during systole (Sm), early diastole (Em), and late diastole (Am) were measured. RESULTS: Study A: CTD-based measurements of displacement were 12% lower than M-mode measurements (95% CI: -18%; -6%). PWTD velocity-time integrals measured at the outer edge...

  11. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    OpenAIRE

    Hasan, Ali A.; Makhlouf, Hoda A.; Mohamed, Alaa R.M.

    2013-01-01

    Background: The discrimination of pleural thickening from minimal pleural effusion may be difficult as both lesions appear as anechoic on grayscale ultrasound, hence, free of “echoes” does not confirm the presence of pleural fluid. Aim of this study: To evaluate the value of color Doppler ultrasound in differentiating minimal pleural effusion that could be aspirated from pleural thickening and to compare it with grayscale ultrasound. Patients and methods: This analytic cross-sectional s...

  12. RGB Color Cube-Based Histogram Specification for Hue-Preserving Color Image Enhancement

    Directory of Open Access Journals (Sweden)

    Kohei Inoue

    2017-07-01

    Full Text Available A large number of color image enhancement methods are based on the methods for grayscale image enhancement in which the main interest is contrast enhancement. However, since colors usually have three attributes, including hue, saturation and intensity of more than only one attribute of grayscale values, the naive application of the methods for grayscale images to color images often results in unsatisfactory consequences. Conventional hue-preserving color image enhancement methods utilize histogram equalization (HE for enhancing the contrast. However, they cannot always enhance the saturation simultaneously. In this paper, we propose a histogram specification (HS method for enhancing the saturation in hue-preserving color image enhancement. The proposed method computes the target histogram for HS on the basis of the geometry of RGB (rad, green and blue color space, whose shape is a cube with a unit side length. Therefore, the proposed method includes no parameters to be set by users. Experimental results show that the proposed method achieves higher color saturation than recent parameter-free methods for hue-preserving color image enhancement. As a result, the proposed method can be used for an alternative method of HE in hue-preserving color image enhancement.

  13. Doppler optical cardiogram gated 2D color flow imaging at 1000 fps and 4D in vivo visualization of embryonic heart at 45 fps on a swept source OCT system.

    Science.gov (United States)

    Mariampillai, Adrian; Standish, Beau A; Munce, Nigel R; Randall, Cristina; Liu, George; Jiang, James Y; Cable, Alex E; Vitkin, I A; Yang, Victor X D

    2007-02-19

    We report a Doppler optical cardiogram gating technique for increasing the effective frame rate of Doppler optical coherence tomography (DOCT) when imaging periodic motion as found in the cardiovascular system of embryos. This was accomplished with a Thorlabs swept-source DOCT system that simultaneously acquired and displayed structural and Doppler images at 12 frames per second (fps). The gating technique allowed for ultra-high speed visualization of the blood flow pattern in the developing hearts of African clawed frog embryos (Xenopus laevis) at up to 1000 fps. In addition, four-dimensional (three spatial dimensions + temporal) Doppler imaging at 45 fps was demonstrated using this gating technique, producing detailed visualization of the complex cardiac motion and hemodynamics in a beating heart.

  14. Image Transform Based on the Distribution of Representative Colors for Color Deficient

    Science.gov (United States)

    Ohata, Fukashi; Kudo, Hiroaki; Matsumoto, Tetsuya; Takeuchi, Yoshinori; Ohnishi, Noboru

    This paper proposes the method to convert digital image containing distinguishing difficulty sets of colors into the image with high visibility. We set up four criteria, automatically processing by a computer, retaining continuity in color space, not making images into lower visible for people with normal color vision, and not making images not originally having distinguishing difficulty sets of colors into lower visible. We conducted the psychological experiment. We obtained the result that the visibility of a converted image had been improved at 60% for 40 images, and we confirmed the main criterion of the continuity in color space was kept.

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  17. The Assessment of Left Ventricular Time-Varying Radius Using Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Fardin Mirbolouk

    2012-03-01

    Full Text Available Background: Left ventricular twist/torsion is believed to be a sensitive indicator of systolic and diastolic performance. To obtain circumferential rotation using tissue Doppler imaging, we need to estimate the time-varying radius of the left ventricle throughout the cardiac cycle to convert the tangential velocity into angular velocity. Objectives: The aim of this study was to investigate accuracy of measured LV radius using tissue Doppler imaging throughout the cardiac cycle compared to two-dimensional (2D imaging. Methods: A total of 35 subjects (47±12 years old underwent transthoracic echocardiographic standard examinations. Left ventricular radius during complete cardiac cycle measured using tissue Doppler and 2D-imaging at basal and apical short axis levels. For this reason, the 2D-images and velocity-time data derived and transferred to a personal computer for off-line analysis. 2D image frames analyzed via a program written in the MATLAB software. Velocity-time data from anteroseptal at basal level (or anterior wall at apical level and posterior walls transferred to a spreadsheet Excel program for the radius calculations. Linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the tissue Doppler and 2D-measured radii throughout the cardiac cycle. Results: There was significant correlation between tissue Doppler and 2D-measured radii and the Pearson correlation coefficients were 0.84 to 0.97 (P<0.05. Bland-Altman analysis by constructing the 95% limits of agreement showed that the good agreements existed between the two methods. Conclusion: It can be concluded from our experience that the tissue Doppler imaging can reasonably estimate radius of the left ventricle throughout the cardiac cycle.

  18. Recent progress in color image intensifier

    International Nuclear Information System (INIS)

    Nittoh, K.

    2010-01-01

    A multi-color scintillator based high-sensitive, wide dynamic range and long-life X-ray image intensifier (Ultimage TM ) has been developed. Europium activated Y 2 O 2 S scintillator, emitting red, green and blue wavelength photons of different intensities, is utilized as the output fluorescent screen of the intensifier. By combining this image intensifier with a suitably tuned high sensitive color CCD camera, the sensitivity of the red color component achieved six times higher than that of the conventional image intensifier. Simultaneous emission of a moderate green color and a weak blue color covers different sensitivity regions. This widens the dynamic range by nearly two orders of magnitude. With this image intensifier, it is possible to image complex objects containing various different X-ray transmissions from paper, water or plastic to heavy metals at a time. This color scintillator based image intensifier is widely used in X-ray inspections of various fields. (author)

  19. Enriching text with images and colored light

    Science.gov (United States)

    Sekulovski, Dragan; Geleijnse, Gijs; Kater, Bram; Korst, Jan; Pauws, Steffen; Clout, Ramon

    2008-01-01

    We present an unsupervised method to enrich textual applications with relevant images and colors. The images are collected by querying large image repositories and subsequently the colors are computed using image processing. A prototype system based on this method is presented where the method is applied to song lyrics. In combination with a lyrics synchronization algorithm the system produces a rich multimedia experience. In order to identify terms within the text that may be associated with images and colors, we select noun phrases using a part of speech tagger. Large image repositories are queried with these terms. Per term representative colors are extracted using the collected images. Hereto, we either use a histogram-based or a mean shift-based algorithm. The representative color extraction uses the non-uniform distribution of the colors found in the large repositories. The images that are ranked best by the search engine are displayed on a screen, while the extracted representative colors are rendered on controllable lighting devices in the living room. We evaluate our method by comparing the computed colors to standard color representations of a set of English color terms. A second evaluation focuses on the distance in color between a queried term in English and its translation in a foreign language. Based on results from three sets of terms, a measure of suitability of a term for color extraction based on KL Divergence is proposed. Finally, we compare the performance of the algorithm using either the automatically indexed repository of Google Images and the manually annotated Flickr.com. Based on the results of these experiments, we conclude that using the presented method we can compute the relevant color for a term using a large image repository and image processing.

  20. Color image guided depth image super resolution using fusion filter

    Science.gov (United States)

    He, Jin; Liang, Bin; He, Ying; Yang, Jun

    2018-04-01

    Depth cameras are currently playing an important role in many areas. However, most of them can only obtain lowresolution (LR) depth images. Color cameras can easily provide high-resolution (HR) color images. Using color image as a guide image is an efficient way to get a HR depth image. In this paper, we propose a depth image super resolution (SR) algorithm, which uses a HR color image as a guide image and a LR depth image as input. We use the fusion filter of guided filter and edge based joint bilateral filter to get HR depth image. Our experimental results on Middlebury 2005 datasets show that our method can provide better quality in HR depth images both numerically and visually.

  1. Image color reduction method for color-defective observers using a color palette composed of 20 particular colors

    Science.gov (United States)

    Sakamoto, Takashi

    2015-01-01

    This study describes a color enhancement method that uses a color palette especially designed for protan and deutan defects, commonly known as red-green color blindness. The proposed color reduction method is based on a simple color mapping. Complicated computation and image processing are not required by using the proposed method, and the method can replace protan and deutan confusion (p/d-confusion) colors with protan and deutan safe (p/d-safe) colors. Color palettes for protan and deutan defects proposed by previous studies are composed of few p/d-safe colors. Thus, the colors contained in these palettes are insufficient for replacing colors in photographs. Recently, Ito et al. proposed a p/dsafe color palette composed of 20 particular colors. The author demonstrated that their p/d-safe color palette could be applied to image color reduction in photographs as a means to replace p/d-confusion colors. This study describes the results of the proposed color reduction in photographs that include typical p/d-confusion colors, which can be replaced. After the reduction process is completed, color-defective observers can distinguish these confusion colors.

  2. Color enhancement in multispectral image of human skin

    Science.gov (United States)

    Mitsui, Masanori; Murakami, Yuri; Obi, Takashi; Yamaguchi, Masahiro; Ohyama, Nagaaki

    2003-07-01

    Multispectral imaging is receiving attention in medical color imaging, as high-fidelity color information can be acquired by the multispectral image capturing. On the other hand, as color enhancement in medical color image is effective for distinguishing lesion from normal part, we apply a new technique for color enhancement using multispectral image to enhance the features contained in a certain spectral band, without changing the average color distribution of original image. In this method, to keep the average color distribution, KL transform is applied to spectral data, and only high-order KL coefficients are amplified in the enhancement. Multispectral images of human skin of bruised arm are captured by 16-band multispectral camera, and the proposed color enhancement is applied. The resultant images are compared with the color images reproduced assuming CIE D65 illuminant (obtained by natural color reproduction technique). As a result, the proposed technique successfully visualizes unclear bruised lesions, which are almost invisible in natural color images. The proposed technique will provide support tool for the diagnosis in dermatology, visual examination in internal medicine, nursing care for preventing bedsore, and so on.

  3. Imaging doppler lidar for wind turbine wake profiling

    Science.gov (United States)

    Bossert, David J.

    2015-11-19

    An imaging Doppler lidar (IDL) enables the measurement of the velocity distribution of a large volume, in parallel, and at high spatial resolution in the wake of a wind turbine. Because the IDL is non-scanning, it can be orders of magnitude faster than conventional coherent lidar approaches. Scattering can be obtained from naturally occurring aerosol particles. Furthermore, the wind velocity can be measured directly from Doppler shifts of the laser light, so the measurement can be accomplished at large standoff and at wide fields-of-view.

  4. Advances in low-level color image processing

    CERN Document Server

    Smolka, Bogdan

    2014-01-01

    Color perception plays an important role in object recognition and scene understanding both for humans and intelligent vision systems. Recent advances in digital color imaging and computer hardware technology have led to an explosion in the use of color images in a variety of applications including medical imaging, content-based image retrieval, biometrics, watermarking, digital inpainting, remote sensing, visual quality inspection, among many others. As a result, automated processing and analysis of color images has become an active area of research, to which the large number of publications of the past two decades bears witness. The multivariate nature of color image data presents new challenges for researchers and practitioners as the numerous methods developed for single channel images are often not directly applicable to multichannel  ones. The goal of this volume is to summarize the state-of-the-art in the early stages of the color image processing pipeline.

  5. Optimizing color reproduction of natural images

    NARCIS (Netherlands)

    Yendrikhovskij, S.N.; Blommaert, F.J.J.; Ridder, de H.

    1998-01-01

    The paper elaborates on understanding, measuring and optimizing perceived color quality of natural images. We introduce a model for optimal color reproduction of natural scenes which is based on the assumption that color quality of natural images is constrained by perceived naturalness and

  6. Color-flow Doppler US usefulness in upper-extremity venous thrombosis

    International Nuclear Information System (INIS)

    Grassi, C.J.; Polak, J.F.

    1988-01-01

    Compared with its application in the leg veins, US has been used infrequently in the axillary-subclavian veins. Using color-flow Doppler US (CFDUS) as the primary means of follow-up, seven patients from a consecutive 120 venograms in the subgroup of effort thrombosis were restudied to compare CFDUS with venography in blinded fashion. In all seven patients, CFDUS allowed prediction of the thrombus location and the collateral veins; swirl (turbulent venous flow) was detected in two patients, asymmetric jugular distention was seen in three, and the normal response on inspiration was vein collapse, The authors experience indicates the CFDUS shows good correlation with axillary-subclavian venography, that blind areas behind the clavicle can be overcome, and that CFDUS may be preferable in follow-up to avoid patient discomfort or contrast material-induced phlebitis

  7. Dispersed single-phase-step Michelson interferometer for Doppler imaging using sunlight.

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian

    2012-09-15

    A Michelson interferometer is dispersed with a fiber array-fed spectrograph, providing 59 Doppler sensing channels using sunlight in the 510-570 nm wavelength region. The interferometer operates at a single-phase-step mode, which is particularly advantageous in multiplexing and data processing compared to the phase-stepping mode of other interferometer spectrometer instruments. Spectral templates are prepared using a standard solar spectrum and simulated interferometer modulations, such that the correlation function with a measured 1D spectrum determines the Doppler shift. Doppler imaging of a rotating cylinder is demonstrated. The average Doppler sensitivity is ~12 m/s, with some channels reaching ~5 m/s.

  8. [Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia

    2012-01-01

    Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.

  9. Pseudo color ghost coding imaging with pseudo thermal light

    Science.gov (United States)

    Duan, De-yang; Xia, Yun-jie

    2018-04-01

    We present a new pseudo color imaging scheme named pseudo color ghost coding imaging based on ghost imaging but with multiwavelength source modulated by a spatial light modulator. Compared with conventional pseudo color imaging where there is no nondegenerate wavelength spatial correlations resulting in extra monochromatic images, the degenerate wavelength and nondegenerate wavelength spatial correlations between the idle beam and signal beam can be obtained simultaneously. This scheme can obtain more colorful image with higher quality than that in conventional pseudo color coding techniques. More importantly, a significant advantage of the scheme compared to the conventional pseudo color coding imaging techniques is the image with different colors can be obtained without changing the light source and spatial filter.

  10. Composite Techniques Based Color Image Compression

    Directory of Open Access Journals (Sweden)

    Zainab Ibrahim Abood

    2017-03-01

    Full Text Available Compression for color image is now necessary for transmission and storage in the data bases since the color gives a pleasing nature and natural for any object, so three composite techniques based color image compression is implemented to achieve image with high compression, no loss in original image, better performance and good image quality. These techniques are composite stationary wavelet technique (S, composite wavelet technique (W and composite multi-wavelet technique (M. For the high energy sub-band of the 3rd level of each composite transform in each composite technique, the compression parameters are calculated. The best composite transform among the 27 types is the three levels of multi-wavelet transform (MMM in M technique which has the highest values of energy (En and compression ratio (CR and least values of bit per pixel (bpp, time (T and rate distortion R(D. Also the values of the compression parameters of the color image are nearly the same as the average values of the compression parameters of the three bands of the same image.

  11. Evaluation of renal allograft rejection by Doppler sonography and MR imaging

    International Nuclear Information System (INIS)

    Steinberg, H.V.; Nelson, R.C.; Murphy, F.B.; Baumgartner, B.R.; Bourke, E.; Delaney, V.B.; Whelchel, J.B.; Bernardino, M.E.

    1986-01-01

    The authors prospectively studies the efficacy of Doppler sonography and MR imaging in evaluating renal allografts, with specific attention to transplant rejection. Based on study findings, we were unable to make a statement with respect to the appearance or accuracy of diagnosing cyclosporin toxicity or acute tubular necrosis by either modality due to concomitant rejection in the few patients so afflicted. Moreover, the ability to predict and diagnose the presence or absence of allograft rejection was not affected by different serum creatinine values. Most important, however, Doppler sonography was shown to be superior to MR imaging in evaluating for allograft rejection, as evidenced by its higher sensitivity (100% vs. 71%), specificity (88% vs. 75%), and accuracy (96% vs. 73%). Thus, because of its low cost and ease of accessibility, Doppler sonography should become the primary modality for renal transplant screening

  12. Color Image Segmentation Based on Different Color Space Models Using Automatic GrabCut

    Directory of Open Access Journals (Sweden)

    Dina Khattab

    2014-01-01

    Full Text Available This paper presents a comparative study using different color spaces to evaluate the performance of color image segmentation using the automatic GrabCut technique. GrabCut is considered as one of the semiautomatic image segmentation techniques, since it requires user interaction for the initialization of the segmentation process. The automation of the GrabCut technique is proposed as a modification of the original semiautomatic one in order to eliminate the user interaction. The automatic GrabCut utilizes the unsupervised Orchard and Bouman clustering technique for the initialization phase. Comparisons with the original GrabCut show the efficiency of the proposed automatic technique in terms of segmentation, quality, and accuracy. As no explicit color space is recommended for every segmentation problem, automatic GrabCut is applied with RGB, HSV, CMY, XYZ, and YUV color spaces. The comparative study and experimental results using different color images show that RGB color space is the best color space representation for the set of the images used.

  13. Guided color consistency optimization for image mosaicking

    Science.gov (United States)

    Xie, Renping; Xia, Menghan; Yao, Jian; Li, Li

    2018-01-01

    This paper studies the problem of color consistency correction for sequential images with diverse color characteristics. Existing algorithms try to adjust all images to minimize color differences among images under a unified energy framework, however, the results are prone to presenting a consistent but unnatural appearance when the color difference between images is large and diverse. In our approach, this problem is addressed effectively by providing a guided initial solution for the global consistency optimization, which avoids converging to a meaningless integrated solution. First of all, to obtain the reliable intensity correspondences in overlapping regions between image pairs, we creatively propose the histogram extreme point matching algorithm which is robust to image geometrical misalignment to some extents. In the absence of the extra reference information, the guided initial solution is learned from the major tone of the original images by searching some image subset as the reference, whose color characteristics will be transferred to the others via the paths of graph analysis. Thus, the final results via global adjustment will take on a consistent color similar to the appearance of the reference image subset. Several groups of convincing experiments on both the synthetic dataset and the challenging real ones sufficiently demonstrate that the proposed approach can achieve as good or even better results compared with the state-of-the-art approaches.

  14. Performance Analysis of Segmentation of Hyperspectral Images Based on Color Image Segmentation

    Directory of Open Access Journals (Sweden)

    Praveen Agarwal

    2017-06-01

    Full Text Available Image segmentation is a fundamental approach in the field of image processing and based on user’s application .This paper propose an original and simple segmentation strategy based on the EM approach that resolves many informatics problems about hyperspectral images which are observed by airborne sensors. In a first step, to simplify the input color textured image into a color image without texture. The final segmentation is simply achieved by a spatially color segmentation using feature vector with the set of color values contained around the pixel to be classified with some mathematical equations. The spatial constraint allows taking into account the inherent spatial relationships of any image and its color. This approach provides effective PSNR for the segmented image. These results have the better performance as the segmented images are compared with Watershed & Region Growing Algorithm and provide effective segmentation for the Spectral Images & Medical Images.

  15. Color camera computed tomography imaging spectrometer for improved spatial-spectral image accuracy

    Science.gov (United States)

    Wilson, Daniel W. (Inventor); Bearman, Gregory H. (Inventor); Johnson, William R. (Inventor)

    2011-01-01

    Computed tomography imaging spectrometers ("CTIS"s) having color focal plane array detectors are provided. The color FPA detector may comprise a digital color camera including a digital image sensor, such as a Foveon X3.RTM. digital image sensor or a Bayer color filter mosaic. In another embodiment, the CTIS includes a pattern imposed either directly on the object scene being imaged or at the field stop aperture. The use of a color FPA detector and the pattern improves the accuracy of the captured spatial and spectral information.

  16. Magnetic resonance angiography in renal grafts. Comparison with color Doppler echography

    International Nuclear Information System (INIS)

    Yanagisawa, Takayoshi; Otsubo, Osamu; Nozaki, Harushige

    1995-01-01

    We studied relationship between magnetic resonance angiography (MRA) of renal graft and renal graft function in 14 renal transplantations (10 from living donors, 4 from cadaveric donors). MRA was performed on 0.3-T permanent magnet system (MRP 7000, HITACHI, JAPAN) using 2 dimensional time of flight technique (FOV: 350 mm 2 , RT: 60 msec, ET: 10 msec, FA: 90deg, Slice: volumes 60, thickness 4 mm, overlap 1 mm). As for parameters of renal graft function, we evaluated color doppler echography (CD) of transplanted renal artery, renal blood flow (RBF), velocity of interlobar artery (ILA) and serum creatinine level (S-Cr). CD, RBF and velocity of ILA were visualized and measured by duplex color doppler echosystem (EUB-565A, HITACHI, JAPAN). Depending on visualization of transplanted renal artery, MRA was graded into 3 groups (MA Grade 3: visualization of ILA, MA Grade 2: visualization of segmental artery and the first branch but no visualization of ILA, MA Grade 1: visualization of main renal artery only). Likewise, visualization of CD was graded into 3 groups (CD Grade 3: good visualization of arcuate artery (AA) and ILA, CD Grade 2: poor visualization of AA but good visualization of ILA, CD Grade 1: poor visualization of ILA). The MRA grading had a very significant correlation (r=0.79, p<0.001) with the CD grading. As for RBF and velocity of ILA, the RBF of MA Grade 3 group (n=8) was significantly (p<0.05) higher than the MA Grade 2 group (n=4) and the MA Grade 1 group (n=2), and the velocity of ILA of MA Grade 3 group was also higher than the above groups but not significantly. Furthermore, the S-Cr of MA Grade 3 was significantly (p<0.05) lower than the others. These results showed that MRA of renal graft had a qualitative index of renal graft function. (author)

  17. Stamp Detection in Color Document Images

    DEFF Research Database (Denmark)

    Micenkova, Barbora; van Beusekom, Joost

    2011-01-01

    , moreover, it can be imprinted with a variable quality and rotation. Previous methods were restricted to detection of stamps of particular shapes or colors. The method presented in the paper includes segmentation of the image by color clustering and subsequent classification of candidate solutions...... by geometrical and color-related features. The approach allows for differentiation of stamps from other color objects in the document such as logos or texts. For the purpose of evaluation, a data set of 400 document images has been collected, annotated and made public. With the proposed method, recall of 83...

  18. Visual wetness perception based on image color statistics.

    Science.gov (United States)

    Sawayama, Masataka; Adelson, Edward H; Nishida, Shin'ya

    2017-05-01

    Color vision provides humans and animals with the abilities to discriminate colors based on the wavelength composition of light and to determine the location and identity of objects of interest in cluttered scenes (e.g., ripe fruit among foliage). However, we argue that color vision can inform us about much more than color alone. Since a trichromatic image carries more information about the optical properties of a scene than a monochromatic image does, color can help us recognize complex material qualities. Here we show that human vision uses color statistics of an image for the perception of an ecologically important surface condition (i.e., wetness). Psychophysical experiments showed that overall enhancement of chromatic saturation, combined with a luminance tone change that increases the darkness and glossiness of the image, tended to make dry scenes look wetter. Theoretical analysis along with image analysis of real objects indicated that our image transformation, which we call the wetness enhancing transformation, is consistent with actual optical changes produced by surface wetting. Furthermore, we found that the wetness enhancing transformation operator was more effective for the images with many colors (large hue entropy) than for those with few colors (small hue entropy). The hue entropy may be used to separate surface wetness from other surface states having similar optical properties. While surface wetness and surface color might seem to be independent, there are higher order color statistics that can influence wetness judgments, in accord with the ecological statistics. The present findings indicate that the visual system uses color image statistics in an elegant way to help estimate the complex physical status of a scene.

  19. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  20. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.

    Science.gov (United States)

    Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei

    2011-02-01

    Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  1. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    OpenAIRE

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in f...

  2. Measurement of portal blood flow in healthy individuals: a comparison between magnetic resonance imaging and Doppler ultrasound

    International Nuclear Information System (INIS)

    Costa, Juliana Dantas da; Sebastiane, Patricia Moreno; Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; D'Ippolito, Giuseppe

    2008-01-01

    Objective: To evaluate the inter-observer agreement between Doppler ultrasonography and magnetic resonance imaging in the quantification of portal blood flow in healthy individuals, as well as evaluating the reproducibility of both methods. Materials and methods: A prospective, transverse, observational and self-paired study was developed evaluating 20 healthy volunteers whose portal blood flow was measured by means of Doppler ultrasonography and magnetic resonance imaging performed by two independent observers. Interobserver and inter method agreements were calculated using the intra class and Pearson's correlation coefficients. Results: The agreement between Doppler ultrasonography and magnetic resonance imaging was low (intra class coefficient: 1.9%-18.2%; Pearson's coefficient: 0.1%-13.7%; p=0.565). Mean values for the portal blood flow measured by Doppler ultrasonography and magnetic resonance imaging were respectively 0.768 l/min and 0.742 l/min. Interobserver agreement for quantification of the portal blood flow by Doppler ultrasonography and magnetic resonance imaging was respectively reasonable (intra class coefficient: 43.3%; Pearson's coefficient: 43.0%) and excellent (intra class coefficient: 91.4%; Pearson's coefficient: 93.4%). Conclusion: In the present study, magnetic resonance imaging demonstrated to be a reliable method for quantifying the portal blood flow, with a higher interobserver agreement than Doppler ultrasonography. The inter method agreement was low. (author)

  3. Vector sparse representation of color image using quaternion matrix analysis.

    Science.gov (United States)

    Xu, Yi; Yu, Licheng; Xu, Hongteng; Zhang, Hao; Nguyen, Truong

    2015-04-01

    Traditional sparse image models treat color image pixel as a scalar, which represents color channels separately or concatenate color channels as a monochrome image. In this paper, we propose a vector sparse representation model for color images using quaternion matrix analysis. As a new tool for color image representation, its potential applications in several image-processing tasks are presented, including color image reconstruction, denoising, inpainting, and super-resolution. The proposed model represents the color image as a quaternion matrix, where a quaternion-based dictionary learning algorithm is presented using the K-quaternion singular value decomposition (QSVD) (generalized K-means clustering for QSVD) method. It conducts the sparse basis selection in quaternion space, which uniformly transforms the channel images to an orthogonal color space. In this new color space, it is significant that the inherent color structures can be completely preserved during vector reconstruction. Moreover, the proposed sparse model is more efficient comparing with the current sparse models for image restoration tasks due to lower redundancy between the atoms of different color channels. The experimental results demonstrate that the proposed sparse image model avoids the hue bias issue successfully and shows its potential as a general and powerful tool in color image analysis and processing domain.

  4. Evaluation of aortic regurgitation using cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tamai, Takuya; Konishi, Tokuji; Okamoto, Shinya; Sakuma, Hajime; Takeda, Kan; Nakano, Takeshi

    1993-01-01

    Cine magnetic resonance imaging (MRI) was used to assess aortic regurgitation (AR) in 13 patients with valvular disease and 3 normal subjects, and the results were compared to color Doppler flow mapping findings. AR produced a signal void in the left ventricle during the diastolic phase in all patients by MRI. There were no false positive or negative results compared with echocardiographic findings. Visual grading of cine MRI gave results similar to color flow Doppler echocardiography (88%). The distance and the area of aortic regurgitation using MRI correlated well with color Doppler flow mapping (r=0.82 and 0.88). However, measurements of distance and area by color flow Doppler tended to be larger than those by cine MRI. With current techniques echocardiography may overestimate the severity of AR as compared with cine MRI. In addition, MRI gives clinically useful information in patients in whom transthoracic Doppler echocardiography is not adequate. (author)

  5. Advanced Color Image Processing and Analysis

    CERN Document Server

    2013-01-01

    This volume does much more than survey modern advanced color processing. Starting with a historical perspective on ways we have classified color, it sets out the latest numerical techniques for analyzing and processing colors, the leading edge in our search to accurately record and print what we see. The human eye perceives only a fraction of available light wavelengths, yet we live in a multicolor world of myriad shining hues. Colors rich in metaphorical associations make us “purple with rage” or “green with envy” and cause us to “see red.” Defining colors has been the work of centuries, culminating in today’s complex mathematical coding that nonetheless remains a work in progress: only recently have we possessed the computing capacity to process the algebraic matrices that reproduce color more accurately. With chapters on dihedral color and image spectrometers, this book provides technicians and researchers with the knowledge they need to grasp the intricacies of today’s color imaging.

  6. Spatial imaging in color and HDR: prometheus unchained

    Science.gov (United States)

    McCann, John J.

    2013-03-01

    The Human Vision and Electronic Imaging Conferences (HVEI) at the IS and T/SPIE Electronic Imaging meetings have brought together research in the fundamentals of both vision and digital technology. This conference has incorporated many color disciplines that have contributed to the theory and practice of today's imaging: color constancy, models of vision, digital output, high-dynamic-range imaging, and the understanding of perceptual mechanisms. Before digital imaging, silver halide color was a pixel-based mechanism. Color films are closely tied to colorimetry, the science of matching pixels in a black surround. The quanta catch of the sensitized silver salts determines the amount of colored dyes in the final print. The rapid expansion of digital imaging over the past 25 years has eliminated the limitations of using small local regions in forming images. Spatial interactions can now generate images more like vision. Since the 1950's, neurophysiology has shown that post-receptor neural processing is based on spatial interactions. These results reinforced the findings of 19th century experimental psychology. This paper reviews the role of HVEI in color, emphasizing the interaction of research on vision and the new algorithms and processes made possible by electronic imaging.

  7. Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor

    NARCIS (Netherlands)

    Serov, Alexander; Steenbergen, Wiendelt; de Mul, F.F.M.

    2002-01-01

    We utilized a complimentary metal oxide semiconductor video camera for fast f low imaging with the laser Doppler technique. A single sensor is used for both observation of the area of interest and measurements of the interference signal caused by dynamic light scattering from moving particles inside

  8. Natural color image segmentation using integrated mechanism

    Institute of Scientific and Technical Information of China (English)

    Jie Xu (徐杰); Pengfei Shi (施鹏飞)

    2003-01-01

    A new method for natural color image segmentation using integrated mechanism is proposed in this paper.Edges are first detected in term of the high phase congruency in the gray-level image. K-mean cluster is used to label long edge lines based on the global color information to estimate roughly the distribution of objects in the image, while short ones are merged based on their positions and local color differences to eliminate the negative affection caused by texture or other trivial features in image. Region growing technique is employed to achieve final segmentation results. The proposed method unifies edges, whole and local color distributions, as well as spatial information to solve the natural image segmentation problem.The feasibility and effectiveness of this method have been demonstrated by various experiments.

  9. Low contrast detectability for color patterns variation of display images

    International Nuclear Information System (INIS)

    Ogura, Akio

    1998-01-01

    In recent years, the radionuclide images are acquired in digital form and displayed with false colors for signal intensity. This color scales for signal intensity have various patterns. In this study, low contrast detectability was compared the performance of gray scale cording with three color scales: the hot color scale, prism color scale and stripe color scale. SPECT images of brain phantom were displayed using four color patterns. These printed images and display images were evaluated with ROC analysis. Display images were indicated higher detectability than printed images. The hot scale and gray scale images indicated better Az of ROC than prism scale images because the prism scale images showed higher false positive rate. (author)

  10. Ultrasonography and color Doppler of proximal gluteal enthesitis in juvenile idiopathic arthritis: a descriptive study

    Directory of Open Access Journals (Sweden)

    Thomsen Carsten

    2011-08-01

    Full Text Available Abstract Background The presence of enthesitis (insertional inflammation in patients with juvenile idiopathic arthritis (JIA is difficult to establish clinically and may influence classification and treatment of the disease. We used ultrasonography (US and color Doppler (CD imaging to detect enthesitis at the small and deep-seated proximal insertion of the gluteus medius fascia on the posterior iliac crest where clinical diagnosis is difficult. The findings in JIA patients were compared with those obtained in healthy controls and with the patients' MRI results. Methods Seventy-six proximal gluteus medius insertions were studied clinically (tenderness to palpation of the posterior iliac crest and by US and CD (echogenicity, thickness, hyperemia in 38 patients with JIA and in 38 healthy controls, respectively (median age 13 years, range 7-18 years. In addition, an additional MRI examination of the sacroiliac joints and iliac crests was performed in all patients. Results In patients with focal, palpable tenderness, US detected decreased echogenicity of the entheses in 53% of the iliac crests (bilateral in 37% and unilateral in 32%. US also revealed significantly thicker entheses in JIA patients compared to healthy controls (p Conclusions According to US, the gluteus medius insertion was thicker in JIA patients than in controls, and it was hypoechoic (enthesitis in about half of the patients. These findings may represent chronic, inactive disease in some of the patients, because there was only limited Doppler flow and MRI contrast enhancement. The present study indicates that US can be useful as an adjunct to clinical examination for improved assessment of enthesitis in JIA. This may influence disease classification, ambition to treat, and choice of treatment regimen.

  11. New Colors for Histology: Optimized Bivariate Color Maps Increase Perceptual Contrast in Histological Images.

    Science.gov (United States)

    Kather, Jakob Nikolas; Weis, Cleo-Aron; Marx, Alexander; Schuster, Alexander K; Schad, Lothar R; Zöllner, Frank Gerrit

    2015-01-01

    Accurate evaluation of immunostained histological images is required for reproducible research in many different areas and forms the basis of many clinical decisions. The quality and efficiency of histopathological evaluation is limited by the information content of a histological image, which is primarily encoded as perceivable contrast differences between objects in the image. However, the colors of chromogen and counterstain used for histological samples are not always optimally distinguishable, even under optimal conditions. In this study, we present a method to extract the bivariate color map inherent in a given histological image and to retrospectively optimize this color map. We use a novel, unsupervised approach based on color deconvolution and principal component analysis to show that the commonly used blue and brown color hues in Hematoxylin-3,3'-Diaminobenzidine (DAB) images are poorly suited for human observers. We then demonstrate that it is possible to construct improved color maps according to objective criteria and that these color maps can be used to digitally re-stain histological images. To validate whether this procedure improves distinguishability of objects and background in histological images, we re-stain phantom images and N = 596 large histological images of immunostained samples of human solid tumors. We show that perceptual contrast is improved by a factor of 2.56 in phantom images and up to a factor of 2.17 in sets of histological tumor images. Thus, we provide an objective and reliable approach to measure object distinguishability in a given histological image and to maximize visual information available to a human observer. This method could easily be incorporated in digital pathology image viewing systems to improve accuracy and efficiency in research and diagnostics.

  12. Color correction of projected image on color-screen for mobile beam-projector

    Science.gov (United States)

    Son, Chang-Hwan; Sung, Soo-Jin; Ha, Yeong-Ho

    2008-01-01

    With the current trend of digital convergence in mobile phones, mobile manufacturers are researching how to develop a mobile beam-projector to cope with the limitations of a small screen size and to offer a better feeling of movement while watching movies or satellite broadcasting. However, mobile beam-projectors may project an image on arbitrary surfaces, such as a colored wall and paper, not on a white screen mainly used in an office environment. Thus, color correction method for the projected image is proposed to achieve good image quality irrespective of the surface colors. Initially, luminance values of original image transformed into the YCbCr space are changed to compensate for spatially nonuniform luminance distribution of arbitrary surface, depending on the pixel values of surface image captured by mobile camera. Next, the chromaticity values for each surface and white-screen image are calculated using the ratio of the sum of three RGB values to one another. Then their chromaticity ratios are multiplied by converted original image through an inverse YCbCr matrix to reduce an influence of modulating the appearance of projected image due to spatially different reflectance on the surface. By projecting corrected original image on a texture pattern or single color surface, the image quality of projected image can be improved more, as well as that of projected image on white screen.

  13. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  14. Color Image Evaluation for Small Space Based on FA and GEP

    Directory of Open Access Journals (Sweden)

    Li Deng

    2014-01-01

    Full Text Available Aiming at the problem that color image is difficult to quantify, this paper proposes an evaluation method of color image for small space based on factor analysis (FA and gene expression programming (GEP and constructs a correlation model between color image factors and comprehensive color image. The basic color samples of small space and color images are evaluated by semantic differential method (SD method, color image factors are selected via dimension reduction in FA, factor score function is established, and by combining the entropy weight method to determine each factor weights then the comprehensive color image score is calculated finally. The best fitting function between color image factors and comprehensive color image is obtained by GEP algorithm, which can predict the users’ color image values. A color image evaluation system for small space is developed based on this model. The color evaluation of a control room on AC frequency conversion rig is taken as an example, verifying the effectiveness of the proposed method. It also can assist the designers in other color designs and provide a fast evaluation tool for testing users’ color image.

  15. Example-Based Image Colorization Using Locality Consistent Sparse Representation.

    Science.gov (United States)

    Bo Li; Fuchen Zhao; Zhuo Su; Xiangguo Liang; Yu-Kun Lai; Rosin, Paul L

    2017-11-01

    Image colorization aims to produce a natural looking color image from a given gray-scale image, which remains a challenging problem. In this paper, we propose a novel example-based image colorization method exploiting a new locality consistent sparse representation. Given a single reference color image, our method automatically colorizes the target gray-scale image by sparse pursuit. For efficiency and robustness, our method operates at the superpixel level. We extract low-level intensity features, mid-level texture features, and high-level semantic features for each superpixel, which are then concatenated to form its descriptor. The collection of feature vectors for all the superpixels from the reference image composes the dictionary. We formulate colorization of target superpixels as a dictionary-based sparse reconstruction problem. Inspired by the observation that superpixels with similar spatial location and/or feature representation are likely to match spatially close regions from the reference image, we further introduce a locality promoting regularization term into the energy formulation, which substantially improves the matching consistency and subsequent colorization results. Target superpixels are colorized based on the chrominance information from the dominant reference superpixels. Finally, to further improve coherence while preserving sharpness, we develop a new edge-preserving filter for chrominance channels with the guidance from the target gray-scale image. To the best of our knowledge, this is the first work on sparse pursuit image colorization from single reference images. Experimental results demonstrate that our colorization method outperforms the state-of-the-art methods, both visually and quantitatively using a user study.

  16. Color standardization and optimization in Whole Slide Imaging

    Directory of Open Access Journals (Sweden)

    Yagi Yukako

    2011-03-01

    Full Text Available Abstract Introduction Standardization and validation of the color displayed by digital slides is an important aspect of digital pathology implementation. While the most common reason for color variation is the variance in the protocols and practices in the histology lab, the color displayed can also be affected by variation in capture parameters (for example, illumination and filters, image processing and display factors in the digital systems themselves. Method We have been developing techniques for color validation and optimization along two paths. The first was based on two standard slides that are scanned and displayed by the imaging system in question. In this approach, one slide is embedded with nine filters with colors selected especially for H&E stained slides (looking like tiny Macbeth color chart; the specific color of the nine filters were determined in our previous study and modified for whole slide imaging (WSI. The other slide is an H&E stained mouse embryo. Both of these slides were scanned and the displayed images were compared to a standard. The second approach was based on our previous multispectral imaging research. Discussion As a first step, the two slide method (above was used to identify inaccurate display of color and its cause, and to understand the importance of accurate color in digital pathology. We have also improved the multispectral-based algorithm for more consistent results in stain standardization. In near future, the results of the two slide and multispectral techniques can be combined and will be widely available. We have been conducting a series of researches and developing projects to improve image quality to establish Image Quality Standardization. This paper discusses one of most important aspects of image quality – color.

  17. New Colors for Histology: Optimized Bivariate Color Maps Increase Perceptual Contrast in Histological Images.

    Directory of Open Access Journals (Sweden)

    Jakob Nikolas Kather

    Full Text Available Accurate evaluation of immunostained histological images is required for reproducible research in many different areas and forms the basis of many clinical decisions. The quality and efficiency of histopathological evaluation is limited by the information content of a histological image, which is primarily encoded as perceivable contrast differences between objects in the image. However, the colors of chromogen and counterstain used for histological samples are not always optimally distinguishable, even under optimal conditions.In this study, we present a method to extract the bivariate color map inherent in a given histological image and to retrospectively optimize this color map. We use a novel, unsupervised approach based on color deconvolution and principal component analysis to show that the commonly used blue and brown color hues in Hematoxylin-3,3'-Diaminobenzidine (DAB images are poorly suited for human observers. We then demonstrate that it is possible to construct improved color maps according to objective criteria and that these color maps can be used to digitally re-stain histological images.To validate whether this procedure improves distinguishability of objects and background in histological images, we re-stain phantom images and N = 596 large histological images of immunostained samples of human solid tumors. We show that perceptual contrast is improved by a factor of 2.56 in phantom images and up to a factor of 2.17 in sets of histological tumor images.Thus, we provide an objective and reliable approach to measure object distinguishability in a given histological image and to maximize visual information available to a human observer. This method could easily be incorporated in digital pathology image viewing systems to improve accuracy and efficiency in research and diagnostics.

  18. The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact

    Science.gov (United States)

    Simon, Julianna C.; Sapozhnikov, Oleg A.; Kreider, Wayne; Breshock, Michael; Williams, James C., Jr.; Bailey, Michael R.

    2018-01-01

    The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.

  19. The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    Science.gov (United States)

    Simon, Julianna C; Sapozhnikov, Oleg A; Kreider, Wayne; Breshock, Michael; Williams, James C; Bailey, Michael R

    2018-01-09

    The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.

  20. The clinical study of 2D and power doppler ultrasound in esophagus varix

    International Nuclear Information System (INIS)

    Li Qiang; Zhou Liang; Zhang Yucheng; Yang Minghua; Ruan Fenglian; Lu Haixia; Li Yue

    2008-01-01

    Objective: To study the application of 2D and Power Doppler Ultrasound in diagnosing the abdominal esophageal varicose veins. Methods: 65 patients under suspicion with chronic hepatitis and cirrhosis for esophageal varicose at esophagus in abdomen section were examined by 2D and Power Doppler Ultrasound.Among them, 35 patients suffered from esophageal varicose veins proved by gastroscopy and the rest did not. Results: On the power doppler imaging map, colored blood stream signals were showed in varicose veins while without signals in non-varicose veins.The diagnostic sensitivity and specificity were 91.4% and 100% respectively. On the two-dimensional image chart, non-echoes were represented in varicose veins. The anteroposterior diameter, right-left diameter, as well as the thickness of esophagus wall were larger in patients with varicose veins than those in non varicose veins cases (P<0.01). Conclusion: 2D combined with Power Doppler Ultrasound was of non-invasive, safe, sensitive and high specificity, which is a valuable and practical tool in diagnosing the esophageal varicose veins. (authors)

  1. Content-Based Image Retrieval Benchmarking: Utilizing color categories and color distributions

    NARCIS (Netherlands)

    van den Broek, Egon; Kisters, Peter M.F.; Vuurpijl, Louis G.

    From a human centered perspective three ingredients for Content-Based Image Retrieval (CBIR) were developed. First, with their existence confirmed by experimental data, 11 color categories were utilized for CBIR and used as input for a new color space segmentation technique. The complete HSI color

  2. Transvaginal color Doppler imaging of uterine contractions in early pregnancies: Significance of uterine contractions in early pregnancy failure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ju; Han, Chang Jin; Suh, Jung Ho; Kwon, Hyuck Chan [Aju University SChool of Medicine, Suwon (Korea, Republic of)

    1999-06-15

    To assess uterine contractions in early pregnancies using transvaginal color Doppler sonography (TVCDS) and to determine the role of uterine contractions in the diagnosis of early pregnancy failure. 76 patients with abnormal pregnancy diagnosed by sonography or histopathology up to 10 weeks of gestation and 38 normal pregnant women as the control group were examines with TVCDS. The presence of uterine contractions was determined by complete or partial disappearance of the color flow signals of vessels within myometrium, and the direction, amplitude (grade 1-3), and interval of uterine contractions were also evaluated. Uterine contractions were identified in 42 (55.3%) of 76 patients with abnormal pregnancy, whereas they were detected only in 2 (5.3%) of 38 normal pregnant women who had initial grade 1 contraction but disappeared in the follow-up study. In 26 patients with blighted ovum or missed abortion, 15 patients (57.7%),showed uterine contraction of grade 1 in 3 cases, grade 2 in 8 cases, and grade 3 in 4 cases and interval from 45 seconds to 5 minutes. In 30 patients with inevitable or incomplete abortion, 23 patients (76.6%) showed uterine contraction of grade 1 in 2 cases, grade 2 in 9 cases, and grade 3 in 12 cases and interval from 1 to 5 minutes. 4 (20%) of 20 patients with threatened abortion had uterine contraction of grade 2 and interval from 2 to 4 minutes. The presence of uterine contractions was significantly different in abnormal pregnancies compared with that of normal and also among the tree different groups of abnormal pregnancies, but the amplitude did not differ.

  3. Transvaginal color Doppler imaging of uterine contractions in early pregnancies: Significance of uterine contractions in early pregnancy failure

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Han, Chang Jin; Suh, Jung Ho; Kwon, Hyuck Chan

    1999-01-01

    To assess uterine contractions in early pregnancies using transvaginal color Doppler sonography (TVCDS) and to determine the role of uterine contractions in the diagnosis of early pregnancy failure. 76 patients with abnormal pregnancy diagnosed by sonography or histopathology up to 10 weeks of gestation and 38 normal pregnant women as the control group were examines with TVCDS. The presence of uterine contractions was determined by complete or partial disappearance of the color flow signals of vessels within myometrium, and the direction, amplitude (grade 1-3), and interval of uterine contractions were also evaluated. Uterine contractions were identified in 42 (55.3%) of 76 patients with abnormal pregnancy, whereas they were detected only in 2 (5.3%) of 38 normal pregnant women who had initial grade 1 contraction but disappeared in the follow-up study. In 26 patients with blighted ovum or missed abortion, 15 patients (57.7%),showed uterine contraction of grade 1 in 3 cases, grade 2 in 8 cases, and grade 3 in 4 cases and interval from 45 seconds to 5 minutes. In 30 patients with inevitable or incomplete abortion, 23 patients (76.6%) showed uterine contraction of grade 1 in 2 cases, grade 2 in 9 cases, and grade 3 in 12 cases and interval from 1 to 5 minutes. 4 (20%) of 20 patients with threatened abortion had uterine contraction of grade 2 and interval from 2 to 4 minutes. The presence of uterine contractions was significantly different in abnormal pregnancies compared with that of normal and also among the tree different groups of abnormal pregnancies, but the amplitude did not differ.

  4. Naturalness and image quality : chroma and hue variation in color images of natural scenes

    NARCIS (Netherlands)

    Ridder, de H.; Blommaert, F.J.J.; Fedorovskaya, E.A.; Rogowitz, B.E.; Allebach, J.P.

    1995-01-01

    The relation between perceptual image quality and naturalness was investigated by varying the colorfulness and hue of color images of natural scenes. These variations were created by digitizing the images, subsequently determining their color point distributions in the CIELUV color space and finally

  5. Naturalness and image quality: Chroma and hue variation in color images of natural scenes

    NARCIS (Netherlands)

    Ridder, de H.; Blommaert, F.J.J.; Fedorovskaya, E.A.; Eschbach, R.; Braun, K.

    1997-01-01

    The relation between perceptual image quality and natural ness was investigated by varying the colorfulness and hue of color images of natural scenes. These variations were created by digitizing the images, subsequently determining their color point distributions in the CIELUV color space and

  6. Color imaging fundamentals and applications

    CERN Document Server

    Reinhard, Erik; Oguz Akyuz, Ahmet; Johnson, Garrett

    2008-01-01

    This book provides the reader with an understanding of what color is, where color comes from, and how color can be used correctly in many different applications. The authors first treat the physics of light and its interaction with matter at the atomic level, so that the origins of color can be appreciated. The intimate relationship between energy levels, orbital states, and electromagnetic waves helps to explain why diamonds shimmer, rubies are red, and the feathers of the Blue Jay are blue. Then, color theory is explained from its origin to the current state of the art, including image captu

  7. Animal Detection in Natural Images: Effects of Color and Image Database

    Science.gov (United States)

    Zhu, Weina; Drewes, Jan; Gegenfurtner, Karl R.

    2013-01-01

    The visual system has a remarkable ability to extract categorical information from complex natural scenes. In order to elucidate the role of low-level image features for the recognition of objects in natural scenes, we recorded saccadic eye movements and event-related potentials (ERPs) in two experiments, in which human subjects had to detect animals in previously unseen natural images. We used a new natural image database (ANID) that is free of some of the potential artifacts that have plagued the widely used COREL images. Color and grayscale images picked from the ANID and COREL databases were used. In all experiments, color images induced a greater N1 EEG component at earlier time points than grayscale images. We suggest that this influence of color in animal detection may be masked by later processes when measuring reation times. The ERP results of go/nogo and forced choice tasks were similar to those reported earlier. The non-animal stimuli induced bigger N1 than animal stimuli both in the COREL and ANID databases. This result indicates ultra-fast processing of animal images is possible irrespective of the particular database. With the ANID images, the difference between color and grayscale images is more pronounced than with the COREL images. The earlier use of the COREL images might have led to an underestimation of the contribution of color. Therefore, we conclude that the ANID image database is better suited for the investigation of the processing of natural scenes than other databases commonly used. PMID:24130744

  8. Animal detection in natural images: effects of color and image database.

    Directory of Open Access Journals (Sweden)

    Weina Zhu

    Full Text Available The visual system has a remarkable ability to extract categorical information from complex natural scenes. In order to elucidate the role of low-level image features for the recognition of objects in natural scenes, we recorded saccadic eye movements and event-related potentials (ERPs in two experiments, in which human subjects had to detect animals in previously unseen natural images. We used a new natural image database (ANID that is free of some of the potential artifacts that have plagued the widely used COREL images. Color and grayscale images picked from the ANID and COREL databases were used. In all experiments, color images induced a greater N1 EEG component at earlier time points than grayscale images. We suggest that this influence of color in animal detection may be masked by later processes when measuring reation times. The ERP results of go/nogo and forced choice tasks were similar to those reported earlier. The non-animal stimuli induced bigger N1 than animal stimuli both in the COREL and ANID databases. This result indicates ultra-fast processing of animal images is possible irrespective of the particular database. With the ANID images, the difference between color and grayscale images is more pronounced than with the COREL images. The earlier use of the COREL images might have led to an underestimation of the contribution of color. Therefore, we conclude that the ANID image database is better suited for the investigation of the processing of natural scenes than other databases commonly used.

  9. Renal transplant assessment with color and pulsed ultrasonography. 1st part: surgical complications

    International Nuclear Information System (INIS)

    Martin Hervas, C.; Gil de Miguel, A.

    1994-01-01

    Color duplex Doppler ultrasound (US) is a highly important technique in kidney transplantation (Tx). We have performed 304 serial explorations in 140 transplant recipients assessing the morphological aspect of the graft, possible dilatation of the urinary tract and collections. Subsequently, we used color and pulsed Doppler to study the renal vascular permeability and the parenchymal resistance, calculating the indices of resistance (RI) and systolic acceleration and the frequencies. We have compared these findings with those observed in a control group of 45 patients with normally functioning grafts and we have also compared them according to the different pathologies, with those of other diagnostic imaging techniques to identify the present role of each in the assessment of kidney transplantation. Plain US plays an important role in the detection of dilations and peri renal collections, and Doppler makes it possible to differentiate, in some cases, obstructive from non obstructive dilatation. The US features of collections are nonspecific. In pulsed Doppler US, the lymphocytes present slightly elevated RI, higher than those produced in secondary dilation, in abscess-related processes and in sub capsular collections with parenchymal compromise. Color duplex Doppler is of greatest use in the diagnosis of vascular complications of Tx, especially thrombosis, stenosis and A-V fistulas. (Author)

  10. Gender-related asymmetric brain vasomotor response to color stimulation: a functional transcranial Doppler spectroscopy study.

    Science.gov (United States)

    Njemanze, Philip C

    2010-11-30

    The present study was designed to examine the effects of color stimulation on cerebral blood mean flow velocity (MFV) in men and women. The study included 16 (8 men and 8 women) right-handed healthy subjects. The MFV was recorded simultaneously in both right and left middle cerebral arteries in Dark and white Light conditions, and during color (Blue, Yellow and Red) stimulations, and was analyzed using functional transcranial Doppler spectroscopy (fTCDS) technique. Color processing occurred within cortico-subcortical circuits. In men, wavelength-differencing of Yellow/Blue pairs occurred within the right hemisphere by processes of cortical long-term depression (CLTD) and subcortical long-term potentiation (SLTP). Conversely, in women, frequency-differencing of Blue/Yellow pairs occurred within the left hemisphere by processes of cortical long-term potentiation (CLTP) and subcortical long-term depression (SLTD). In both genders, there was luminance effect in the left hemisphere, while in men it was along an axis opposite (orthogonal) to that of chromatic effect, in women, it was parallel. Gender-related differences in color processing demonstrated a right hemisphere cognitive style for wavelength-differencing in men, and a left hemisphere cognitive style for frequency-differencing in women. There are potential applications of fTCDS technique, for stroke rehabilitation and monitoring of drug effects.

  11. Brain MR image segmentation using NAMS in pseudo-color.

    Science.gov (United States)

    Li, Hua; Chen, Chuanbo; Fang, Shaohong; Zhao, Shengrong

    2017-12-01

    Image segmentation plays a crucial role in various biomedical applications. In general, the segmentation of brain Magnetic Resonance (MR) images is mainly used to represent the image with several homogeneous regions instead of pixels for surgical analyzing and planning. This paper proposes a new approach for segmenting MR brain images by using pseudo-color based segmentation with Non-symmetry and Anti-packing Model with Squares (NAMS). First of all, the NAMS model is presented. The model can represent the image with sub-patterns to keep the image content and largely reduce the data redundancy. Second, the key idea is proposed that convert the original gray-scale brain MR image into a pseudo-colored image and then segment the pseudo-colored image with NAMS model. The pseudo-colored image can enhance the color contrast in different tissues in brain MR images, which can improve the precision of segmentation as well as directly visual perceptional distinction. Experimental results indicate that compared with other brain MR image segmentation methods, the proposed NAMS based pseudo-color segmentation method performs more excellent in not only segmenting precisely but also saving storage.

  12. Pseudo-color processing in nuclear medical image

    International Nuclear Information System (INIS)

    Wang Zhiqian; Jin Yongjie

    1992-01-01

    The application of pseudo-color technology in nuclear medical image processing is discussed. It includes selection of the number of pseudo-colors, method of realizing pseudo-color transformation, function of pseudo-color transformation and operation on the function

  13. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance.

    Science.gov (United States)

    Park, A Y; Seo, B K; Woo, O H; Jung, K S; Cho, K R; Park, E K; Cha, S H; Cha, J

    2018-03-01

    To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance. A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined. SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (ppower Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; ppower Doppler US for characterising the vascularity in breast masses and improving diagnostic performance. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Cardiac Time Intervals by Tissue Doppler Imaging M-Mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; de Knegt, Martina Chantal

    2016-01-01

    PURPOSE: To define normal values of the cardiac time intervals obtained by tissue Doppler imaging (TDI) M-mode through the mitral valve (MV). Furthermore, to evaluate the association of the myocardial performance index (MPI) obtained by TDI M-mode (MPITDI) and the conventional method of obtaining...

  15. CFA-aware features for steganalysis of color images

    Science.gov (United States)

    Goljan, Miroslav; Fridrich, Jessica

    2015-03-01

    Color interpolation is a form of upsampling, which introduces constraints on the relationship between neighboring pixels in a color image. These constraints can be utilized to substantially boost the accuracy of steganography detectors. In this paper, we introduce a rich model formed by 3D co-occurrences of color noise residuals split according to the structure of the Bayer color filter array to further improve detection. Some color interpolation algorithms, AHD and PPG, impose pixel constraints so tight that extremely accurate detection becomes possible with merely eight features eliminating the need for model richification. We carry out experiments on non-adaptive LSB matching and the content-adaptive algorithm WOW on five different color interpolation algorithms. In contrast to grayscale images, in color images that exhibit traces of color interpolation the security of WOW is significantly lower and, depending on the interpolation algorithm, may even be lower than non-adaptive LSB matching.

  16. A framework for interactive image color editing

    KAUST Repository

    Musialski, Przemyslaw; Cui, Ming; Ye, Jieping; Razdan, Anshuman; Wonka, Peter

    2012-01-01

    We propose a new method for interactive image color replacement that creates smooth and naturally looking results with minimal user interaction. Our system expects as input a source image and rawly scribbled target color values and generates high

  17. Utilization of Multispectral Images for Meat Color Measurements

    DEFF Research Database (Denmark)

    Trinderup, Camilla Himmelstrup; Dahl, Anders Lindbjerg; Carstensen, Jens Michael

    2013-01-01

    This short paper describes how the use of multispectral imaging for color measurement can be utilized in an efficient and descriptive way for meat scientists. The basis of the study is meat color measurements performed with a multispectral imaging system as well as with a standard colorimeter...... of color and color variance than what is obtained by the standard colorimeter....

  18. Color image Segmentation using automatic thresholding techniques

    International Nuclear Information System (INIS)

    Harrabi, R.; Ben Braiek, E.

    2011-01-01

    In this paper, entropy and between-class variance based thresholding methods for color images segmentation are studied. The maximization of the between-class variance (MVI) and the entropy (ME) have been used as a criterion functions to determine an optimal threshold to segment images into nearly homogenous regions. Segmentation results from the two methods are validated and the segmentation sensitivity for the test data available is evaluated, and a comparative study between these methods in different color spaces is presented. The experimental results demonstrate the superiority of the MVI method for color image segmentation.

  19. Assessment of the fetomaternal circulation in threatened abortion by transvaginal color Doppler.

    Science.gov (United States)

    Kurjak, A; Zudenigo, D; Predanic, M; Kupesic, S; Funduk, B

    1994-01-01

    Transvaginal color Doppler was used to investigate blood flow in the fetomaternal circulation of 60 women with threatened abortion and 90 women with normal intrauterine pregnancy. The obtained Doppler sonograms were analyzed and the resistance index (RI) was calculated in the maternal circulation, while in the fetal circulation the pulsatility index (PI) was used. There was no significant difference in the RI values of the maternal circulation between women with normal pregnancies and pregnancies complicated by bleeding, but with normal pregnancy outcome (p > 0.05). No differences in RI values of the uterine, arcuate and radial arteries were found between pregnancies with threatened abortion and normal pregnancy outcome and women with abnormal outcome (p > 0.05). In 9 of 21 women with visible retrochorionic hematoma, the RI of the spiral arteries was higher on the hematoma side in comparison to the opposite side (p abortion, the RI of the spiral arteries was lower in comparison to the control group. Such findings could be caused by the vasodilatating products of inflammation which probably exist in such areas. There was no significant difference in terms of the PI of fetal blood vessels between normal pregnancy and threatened abortions with normal outcome, as well as between threatened abortions with normal outcome and subsequent abortions of live fetuses (p > 0.05).

  20. Doppler coherence imaging of ion dynamics in VINETA.II and ASDEX-upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Gradic, Dorothea; Ford, Oliver; Wolf, Robert [Max-Planck-Institut fuer Plasmaphysik, Greifswald (Germany); Lunt, Tilmann [Max-Planck-Institut fuer Plasmaphysik, Garching (Germany)

    2016-07-01

    In magnetically confining plasma experiments, diagnosis of ion flows is of great importance to measure the plasma response to the magnetic field or the exhaust particle flows in the divertor areas. Doppler coherence imaging spectroscopy (CIS) is a relatively new technique for the observation of plasma bulk ion dynamics. It is a passive optical diagnostic enabling line-integrated measurements to obtain 2D images of the ion flow and ion temperature. The general principle is similar to traditional Doppler spectroscopy, however CIS uses an imaging interferometer to perform narrow-bandwidth Fourier spectroscopy. A major advantage of the coherence imaging technique is the large amount of spatial information recovered. This allows tomographic inversion of the line-integrated measurements. With existing CIS setups, scrape-off-layer and high field side edge impurity flows could be observed in the MAST, core and edge poloidal He II flows in the WEGA stellarator and divertor impurity flows in DIII-D. The main objective of this study is the research of ion dynamics in the small linear plasma experiment VINETA.II and ASDEX-Upgrade. First Doppler CIS measurements from Ar-II plasma discharges in VINETA.II and He-II, C-III divertor flows in ASDEX-Upgrade and their preliminary interpretation will be presented.

  1. Quantifying the effect of colorization enhancement on mammogram images

    Science.gov (United States)

    Wojnicki, Paul J.; Uyeda, Elizabeth; Micheli-Tzanakou, Evangelia

    2002-04-01

    Current methods of radiological displays provide only grayscale images of mammograms. The limitation of the image space to grayscale provides only luminance differences and textures as cues for object recognition within the image. However, color can be an important and significant cue in the detection of shapes and objects. Increasing detection ability allows the radiologist to interpret the images in more detail, improving object recognition and diagnostic accuracy. Color detection experiments using our stimulus system, have demonstrated that an observer can only detect an average of 140 levels of grayscale. An optimally colorized image can allow a user to distinguish 250 - 1000 different levels, hence increasing potential image feature detection by 2-7 times. By implementing a colorization map, which follows the luminance map of the original grayscale images, the luminance profile is preserved and color is isolated as the enhancement mechanism. The effect of this enhancement mechanism on the shape, frequency composition and statistical characteristics of the Visual Evoked Potential (VEP) are analyzed and presented. Thus, the effectiveness of the image colorization is measured quantitatively using the Visual Evoked Potential (VEP).

  2. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  3. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  4. A framework for interactive image color editing

    KAUST Repository

    Musialski, Przemyslaw

    2012-11-08

    We propose a new method for interactive image color replacement that creates smooth and naturally looking results with minimal user interaction. Our system expects as input a source image and rawly scribbled target color values and generates high quality results in interactive rates. To achieve this goal we introduce an algorithm that preserves pairwise distances of the signatures in the original image and simultaneously maps the color to the user defined target values. We propose efficient sub-sampling in order to reduce the computational load and adapt semi-supervised locally linear embedding to optimize the constraints in one objective function. We show the application of the algorithm on typical photographs and compare the results to other color replacement methods. © 2012 Springer-Verlag Berlin Heidelberg.

  5. Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography

    International Nuclear Information System (INIS)

    Clevert, D.A.; Johnson, T.; Flach, P.M.; Strautz, T.I.; Becker, C.; Reiser, M.; Jung, E.M.; Ritter, G.; Gallegos, M.T.; Kubale, R.

    2007-01-01

    The purpose of this study is to investigate the diagnostic potential of color-coded Doppler sonography (CCDS), power-Doppler (PD) and B-flow ultrasound in assessing the degree of extracranial internal carotid artery (ICA) stenosis in comparison to CT-angiography (MD-CTA). Thirty-two consecutive patients referred for CTA with 41 ICA-stenoses were included in this prospective study. MD-CTA was performed using a 64 row scanner with a CTDIvol of 13.1 mGy/cm. In CTA, CCDS, PD and B-flow, the degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Two radiologists performed a quantitative evaluation of the stenoses in consensus blinded to the results of ultrasound. These were correlated to CTA, CCDS, PD and B-flow, intraoperative findings and clinical follow-up. Grading of the stenoses in B-flow ultrasound outperformed the other techniques in terms of accuracy with a correlation coefficient to CTA of 0.88, while PD and CCDS measurements yield coefficients of 0.74 and 0.70. Bland-Altman analysis additionally shows a very little bias of the three US methods between 0.5 and 3.2 %. There is excellent correlation (coefficient 0.88, CI 0.77-0.93) with 64-MD-CTA and B-flow ultrasound in terms of accuracy for intrastenotic and poststenotic diameter. Duplex sonography is useful for screening purposes. (orig.)

  6. A Complete Color Normalization Approach to Histopathology Images Using Color Cues Computed From Saturation-Weighted Statistics.

    Science.gov (United States)

    Li, Xingyu; Plataniotis, Konstantinos N

    2015-07-01

    In digital histopathology, tasks of segmentation and disease diagnosis are achieved by quantitative analysis of image content. However, color variation in image samples makes it challenging to produce reliable results. This paper introduces a complete normalization scheme to address the problem of color variation in histopathology images jointly caused by inconsistent biopsy staining and nonstandard imaging condition. Method : Different from existing normalization methods that either address partial cause of color variation or lump them together, our method identifies causes of color variation based on a microscopic imaging model and addresses inconsistency in biopsy imaging and staining by an illuminant normalization module and a spectral normalization module, respectively. In evaluation, we use two public datasets that are representative of histopathology images commonly received in clinics to examine the proposed method from the aspects of robustness to system settings, performance consistency against achromatic pixels, and normalization effectiveness in terms of histological information preservation. As the saturation-weighted statistics proposed in this study generates stable and reliable color cues for stain normalization, our scheme is robust to system parameters and insensitive to image content and achromatic colors. Extensive experimentation suggests that our approach outperforms state-of-the-art normalization methods as the proposed method is the only approach that succeeds to preserve histological information after normalization. The proposed color normalization solution would be useful to mitigate effects of color variation in pathology images on subsequent quantitative analysis.

  7. Adaptive Residual Interpolation for Color and Multispectral Image Demosaicking.

    Science.gov (United States)

    Monno, Yusuke; Kiku, Daisuke; Tanaka, Masayuki; Okutomi, Masatoshi

    2017-12-01

    Color image demosaicking for the Bayer color filter array is an essential image processing operation for acquiring high-quality color images. Recently, residual interpolation (RI)-based algorithms have demonstrated superior demosaicking performance over conventional color difference interpolation-based algorithms. In this paper, we propose adaptive residual interpolation (ARI) that improves existing RI-based algorithms by adaptively combining two RI-based algorithms and selecting a suitable iteration number at each pixel. These are performed based on a unified criterion that evaluates the validity of an RI-based algorithm. Experimental comparisons using standard color image datasets demonstrate that ARI can improve existing RI-based algorithms by more than 0.6 dB in the color peak signal-to-noise ratio and can outperform state-of-the-art algorithms based on training images. We further extend ARI for a multispectral filter array, in which more than three spectral bands are arrayed, and demonstrate that ARI can achieve state-of-the-art performance also for the task of multispectral image demosaicking.

  8. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  9. Color Processing using Max-trees : A Comparison on Image Compression

    NARCIS (Netherlands)

    Tushabe, Florence; Wilkinson, M.H.F.

    2012-01-01

    This paper proposes a new method of processing color images using mathematical morphology techniques. It adapts the Max-tree image representation to accommodate color and other vectorial images. The proposed method introduces three new ways of transforming the color image into a gray scale image

  10. Mitral valve coaptation and its relationship to late diastolic flow: A color Doppler and vector flow map echocardiographic study in normal subjects.

    Science.gov (United States)

    Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard

    2017-04-01

    Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.

  11. Hiding Information Using different lighting Color images

    Science.gov (United States)

    Majead, Ahlam; Awad, Rash; Salman, Salema S.

    2018-05-01

    The host medium for the secret message is one of the important principles for the designers of steganography method. In this study, the best color image was studied to carrying any secret image.The steganography approach based Lifting Wavelet Transform (LWT) and Least Significant Bits (LSBs) substitution. The proposed method offers lossless and unnoticeable changes in the contrast carrier color image and imperceptible by human visual system (HVS), especially the host images which was captured in dark lighting conditions. The aim of the study was to study the process of masking the data in colored images with different light intensities. The effect of the masking process was examined on the images that are classified by a minimum distance and the amount of noise and distortion in the image. The histogram and statistical characteristics of the cover image the results showed the efficient use of images taken with different light intensities in hiding data using the least important bit substitution method. This method succeeded in concealing textual data without distorting the original image (low light) Lire developments due to the concealment process.The digital image segmentation technique was used to distinguish small areas with masking. The result is that smooth homogeneous areas are less affected as a result of hiding comparing with high light areas. It is possible to use dark color images to send any secret message between two persons for the purpose of secret communication with good security.

  12. “Focal thyroid inferno” on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Fu, Xianshui; Guo, Limei; Zhang, Huabin; Ran, Weiqiang; Fu, Peng; Li, Zhiqiang; Chen, Wen; Jiang, Ling; Wang, Jinrui; Jia, Jianwen

    2012-01-01

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The χ 2 test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using “focal thyroid inferno” as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of “focal thyroid inferno” is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  13. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta

    OpenAIRE

    Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara

    2015-01-01

    Background: The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. Materials and Methods: In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental m...

  14. Associations between abnormal ultrasound color Doppler measures and tendon pain symptoms in badminton players during a season: a prospective cohort study.

    Science.gov (United States)

    Boesen, Anders Ploug; Boesen, Morten Ilum; Torp-Pedersen, Soren; Christensen, Robin; Boesen, Lars; Hölmich, Per; Nielsen, Michael Bachmann; Koenig, Merete Juhl; Hartkopp, Andreas; Ellegaard, Karen; Bliddal, Henning; Langberg, Henning

    2012-03-01

    Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear. Intratendinous flow is present and associated with pain in badminton players, and intratendinous flow and pain increase during a badminton season. Cohort study (prognosis); Level of evidence, 2. Ninety-five semiprofessional badminton players were included in the study at a tournament at the start of the badminton season. All players were interviewed regarding pain. The anterior knee tendons and Achilles tendons were studied. Each tendon was scored using a quantitative grading system (grades 0-5) and a qualitative scoring system (color fraction) using color Doppler ultrasound. Eight months later, 86 of the players (91%) were retested by the same investigators during an equivalent badminton tournament (including 1032 tendon regions; 86 players with 4 tendons each with 3 regions), thus forming the study group. At the start of the season, 24 players (28%) experienced pain in 37 tendons (11%), and at the end of the season, 31 players (36%) experienced pain in 51 tendons (15%), which was a statistically significant increase (P = .0002). Abnormal flow was found in 230 tendon regions in 71 players (83%) at the start of the season compared with 78 tendon regions in 41 players (48%) at the follow-up. The decrease in abnormal flow was statistically significant (P < .0001). Of the 37 painful tendons at the start of the season, 25 had abnormal flow (68%). In contrast, 131 tendons (85%) with abnormal flow at the start of the season were pain free. At the end of the season, 18 of the 51 painful tendons (35%) had abnormal flow. Ninety-six of the 131 pain-free tendons (73%) with abnormal flow at the start of the season were normalized (no pain and normal flow) at the end of the season. It was not possible to verify any association between intratendinous flow and pain at the start of the season or at

  15. Identificação pelo eco-Doppler colorido de fístula arteriovenosa na trombose venosa profunda Arteriovenous fistula in deep venous thrombosis identified by color-flow Doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Fanilda Souto Barros

    2006-09-01

    Full Text Available Os três casos são referentes a pacientes em tratamento para trombose venosa profunda encaminhados ao laboratório vascular para avaliação da recanalização e/ou progressão do processo trombótico. Durante o estudo pelo eco-Doppler colorido, foram identificados sinais ecográficos compatíveis com fístula arteriovenosa no interior do trombo e adjacente à parede venosa.We report on a case series of three patients undergoing treatment for deep venous thrombosis, referred to our vascular laboratory for evaluation of recanalization and/or progression of the thrombotic process. During the color-flow Doppler ultrasonography, we identified ultrasound signs typical of arteriovenous fistula flow pattern within the thrombus and adjacent to the venous wall.

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  17. Stokes image reconstruction for two-color microgrid polarization imaging systems.

    Science.gov (United States)

    Lemaster, Daniel A

    2011-07-18

    The Air Force Research Laboratory has developed a new microgrid polarization imaging system capable of simultaneously reconstructing linear Stokes parameter images in two colors on a single focal plane array. In this paper, an effective method for extracting Stokes images is presented for this type of camera system. It is also shown that correlations between the color bands can be exploited to significantly increase overall spatial resolution. Test data is used to show the advantages of this approach over bilinear interpolation. The bounds (in terms of available reconstruction bandwidth) on image resolution are also provided.

  18. Research of image retrieval technology based on color feature

    Science.gov (United States)

    Fu, Yanjun; Jiang, Guangyu; Chen, Fengying

    2009-10-01

    Recently, with the development of the communication and the computer technology and the improvement of the storage technology and the capability of the digital image equipment, more and more image resources are given to us than ever. And thus the solution of how to locate the proper image quickly and accurately is wanted.The early method is to set up a key word for searching in the database, but now the method has become very difficult when we search much more picture that we need. In order to overcome the limitation of the traditional searching method, content based image retrieval technology was aroused. Now, it is a hot research subject.Color image retrieval is the important part of it. Color is the most important feature for color image retrieval. Three key questions on how to make use of the color characteristic are discussed in the paper: the expression of color, the abstraction of color characteristic and the measurement of likeness based on color. On the basis, the extraction technology of the color histogram characteristic is especially discussed. Considering the advantages and disadvantages of the overall histogram and the partition histogram, a new method based the partition-overall histogram is proposed. The basic thought of it is to divide the image space according to a certain strategy, and then calculate color histogram of each block as the color feature of this block. Users choose the blocks that contain important space information, confirming the right value. The system calculates the distance between the corresponding blocks that users choosed. Other blocks merge into part overall histograms again, and the distance should be calculated. Then accumulate all the distance as the real distance between two pictures. The partition-overall histogram comprehensive utilizes advantages of two methods above, by choosing blocks makes the feature contain more spatial information which can improve performance; the distances between partition-overall histogram

  19. Evaluation the index of ophthalmic arteries in diabetic patients with retinopathy compared to diabetic patients without retinopathy using color Doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Mohammad Ghasem Hanafi

    2016-12-01

    Full Text Available Diabetic retinopathy is the most common eye complication in diabetic patients that early detection of this complication is essential. The aim of this study was to evaluate ophthalmic artery index in diabetic retinopathy by Doppler ultrasound. . In this cross-sectional study, 64 patients were studied in 4 groups (healthy, diabetic without retinopathy, background retinopathy and proliferative retinopathy. Resistance index (RI and Pulsatile Index (PI were assessed by color Doppler ultrasound. The obtained data were analyzed by ANOVA and chi-square test and ROC curve. RI in diabetic patients with proliferative retinopathy has the highest mean (0.83 and the lowest mean was observed in healthy subjects (0.54 (P <0.001 as well as in PI, the highest rate was in diabetic patients with proliferative retinopathy (1.41 and the lowest was in healthy subjects (0.92 (P <0.001. The results of our study showed that the sensitivity, specificity, positive and negative predictive values and overall accuracy of RI and PI in diabetic patients with proliferative retinopathy in the best cut-off points (0.645 and 1.0175 respectively were 100%.Ophthalmic artery index RI and PI was significantly increased in patients with diabetic retinopathy and the sensitivity and specificity for detection retinopathy was 100%. Color Doppler ultrasound method is more efficient for screening diabetic patients with retinopathy.

  20. Color-Based Image Retrieval from High-Similarity Image Databases

    DEFF Research Database (Denmark)

    Hansen, Michael Adsetts Edberg; Carstensen, Jens Michael

    2003-01-01

    Many image classification problems can fruitfully be thought of as image retrieval in a "high similarity image database" (HSID) characterized by being tuned towards a specific application and having a high degree of visual similarity between entries that should be distinguished. We introduce...... a method for HSID retrieval using a similarity measure based on a linear combination of Jeffreys-Matusita (JM) distances between distributions of color (and color derivatives) estimated from a set of automatically extracted image regions. The weight coefficients are estimated based on optimal retrieval...... performance. Experimental results on the difficult task of visually identifying clones of fungal colonies grown in a petri dish and categorization of pelts show a high retrieval accuracy of the method when combined with standardized sample preparation and image acquisition....

  1. Assessment of regional systolic and diastolic myocardial function using tissue Doppler and strain imaging in dogs with dilated cardiomyopathy.

    Science.gov (United States)

    Chetboul, Valérie; Gouni, Vassiliki; Sampedrano, Carolina Carlos; Tissier, Renaud; Serres, François; Pouchelon, Jean-Louis

    2007-01-01

    Tissue Doppler Imaging (TDI) or strain (St) imaging could provide sensitive indices for early detection and treatment follow-up of canine dilated cardiomyopathy (DCM). Analysis of TDI and St features in dogs with overt DCM is a prerequisite before using these new criteria in prospective screenings of predisposed families or in clinical trials. Radial and longitudinal right and left myocardial motion, assessed by TDI and St variables, is altered in dogs with DCM. Case records for 26 dogs; 14 with DCM and 12 healthy controls of comparable age and weight were reviewed. A retrospective analysis was conducted of conventional echocardiography, 2-dimensional color TDI, and St imaging data. The DCM group was characterized by decreases in radial and longitudinal systolic velocity gradients of the left ventricular free wall (LVFW), radial and longitudinal absolute values of peak systolic St of the LVFW, and longitudinal systolic right ventricular (RV) velocities (all P canine DCM.

  2. Color Doppler imaging and measurements of intraovarian and intrauterine vascularization on basal ultrasound examination in spontaneous ovulatory and anovulatory cycles

    Directory of Open Access Journals (Sweden)

    Kutlešić Ranko

    2008-01-01

    Full Text Available Background/Aim. Any organs functioning directly depends on vascularization. It applies also to the uterus and ovary which go through changes of vascularization during a menstruation cycle. The aim of this investigation was to determine differences in intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4 between spontaneous ovulatory and anovulatory cycles. Methods. This prospective clinical investigation included 205 patients divided into two groups: with ovulatory and with anovulatory cycles. Results. Resistance to ovarian arterioral stromal blood flow was significantly lower in the patients with ovulatory cycles (pulsatile index - PI 0.97 ± 0.4 vs 1.93 ± 1.37; p = 0.001737; and (resistance index - RI 0.55 ± 0.12 vs 0.68 ± 0.14; p = 0.040033. There were no statistically significant differences in arcuate arterioral blood flow in the pateints with ovulatory and anovulatory cycles (PI 1.21 ± 0.34 vs 61 ± 0,61 p = 0.136161 and RI 0.64 ± 0.11 vs 0.74 ± 0.07; p = 0.136649. The patients with ovulatory cycles had lower uterine radial arterioral blood flow than the patients with anovulatory cycles (PI 1.001 ± 0.22 vs 1.61 ± 0.23 p = 0.007501 and RI 0.55 ± 0.08 vs 0.71 ± 0.12; p = 0,0460113. The patients with ovulatory cycles had lower subendometrial arterioral blood flow resistance (PI 0.69 ± 0.19 vs 1.385±0.09; p = 0.00622 and RI 0.44 ± 0.09 vs 0.65 ± 0.02; p = 0.027458. Conclusion. Color Doppler ultrasuond imaging and measurements of intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4, showed lower resistance to blood flow in ovulatory than in anovulatory cycles.

  3. Color Segmentation of Homogeneous Areas on Colposcopical Images

    Directory of Open Access Journals (Sweden)

    Kosteley Yana

    2016-01-01

    Full Text Available The article provides an analysis of image processing and color segmentation applied to the problem of selection of homogeneous regions in the parameters of the color model. Methods of image processing such as Gaussian filter, median filter, histogram equalization and mathematical morphology are considered. The segmentation algorithm with the parameters of color components is presented, followed by isolation of the resulting connected component of a binary segmentation mask. Analysis of methods performed on images colposcopic research.

  4. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  5. Obtention of tumor volumes in PET images stacks using techniques of colored image segmentation

    International Nuclear Information System (INIS)

    Vieira, Jose W.; Lopes Filho, Ferdinand J.; Vieira, Igor F.

    2014-01-01

    This work demonstrated step by step how to segment color images of the chest of an adult in order to separate the tumor volume without significantly changing the values of the components R (Red), G (Green) and B (blue) of the colors of the pixels. For having information which allow to build color map you need to segment and classify the colors present at appropriate intervals in images. The used segmentation technique is to select a small rectangle with color samples in a given region and then erase with a specific color called 'rubber' the other regions of image. The tumor region was segmented into one of the images available and the procedure is displayed in tutorial format. All necessary computational tools have been implemented in DIP (Digital Image Processing), software developed by the authors. The results obtained, in addition to permitting the construction the colorful map of the distribution of the concentration of activity in PET images will also be useful in future work to enter tumors in voxel phantoms in order to perform dosimetric assessments

  6. New feature of the neutron color image intensifier

    Science.gov (United States)

    Nittoh, Koichi; Konagai, Chikara; Noji, Takashi; Miyabe, Keisuke

    2009-06-01

    We developed prototype neutron color image intensifiers with high-sensitivity, wide dynamic range and long-life characteristics. In the prototype intensifier (Gd-Type 1), a terbium-activated Gd 2O 2S is used as the input-screen phosphor. In the upgraded model (Gd-Type 2), Gd 2O 3 and CsI:Na are vacuum deposited to form the phosphor layer, which improved the sensitivity and the spatial uniformity. A europium-activated Y 2O 2S multi-color scintillator, emitting red, green and blue photons with different intensities, is utilized as the output screen of the intensifier. By combining this image intensifier with a suitably tuned high-sensitive color CCD camera, higher sensitivity and wider dynamic range could be simultaneously attained than that of the conventional P20-phosphor-type image intensifier. The results of experiments at the JRR-3M neutron radiography irradiation port (flux: 1.5×10 8 n/cm 2/s) showed that these neutron color image intensifiers can clearly image dynamic phenomena with a 30 frame/s video picture. It is expected that the color image intensifier will be used as a new two-dimensional neutron sensor in new application fields.

  7. New feature of the neutron color image intensifier

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Konagai, Chikara; Noji, Takashi; Miyabe, Keisuke

    2009-01-01

    We developed prototype neutron color image intensifiers with high-sensitivity, wide dynamic range and long-life characteristics. In the prototype intensifier (Gd-Type 1), a terbium-activated Gd 2 O 2 S is used as the input-screen phosphor. In the upgraded model (Gd-Type 2), Gd 2 O 3 and CsI:Na are vacuum deposited to form the phosphor layer, which improved the sensitivity and the spatial uniformity. A europium-activated Y 2 O 2 S multi-color scintillator, emitting red, green and blue photons with different intensities, is utilized as the output screen of the intensifier. By combining this image intensifier with a suitably tuned high-sensitive color CCD camera, higher sensitivity and wider dynamic range could be simultaneously attained than that of the conventional P20-phosphor-type image intensifier. The results of experiments at the JRR-3M neutron radiography irradiation port (flux: 1.5x10 8 n/cm 2 /s) showed that these neutron color image intensifiers can clearly image dynamic phenomena with a 30 frame/s video picture. It is expected that the color image intensifier will be used as a new two-dimensional neutron sensor in new application fields.

  8. Color correction with blind image restoration based on multiple images using a low-rank model

    Science.gov (United States)

    Li, Dong; Xie, Xudong; Lam, Kin-Man

    2014-03-01

    We present a method that can handle the color correction of multiple photographs with blind image restoration simultaneously and automatically. We prove that the local colors of a set of images of the same scene exhibit the low-rank property locally both before and after a color-correction operation. This property allows us to correct all kinds of errors in an image under a low-rank matrix model without particular priors or assumptions. The possible errors may be caused by changes of viewpoint, large illumination variations, gross pixel corruptions, partial occlusions, etc. Furthermore, a new iterative soft-segmentation method is proposed for local color transfer using color influence maps. Due to the fact that the correct color information and the spatial information of images can be recovered using the low-rank model, more precise color correction and many other image-restoration tasks-including image denoising, image deblurring, and gray-scale image colorizing-can be performed simultaneously. Experiments have verified that our method can achieve consistent and promising results on uncontrolled real photographs acquired from the Internet and that it outperforms current state-of-the-art methods.

  9. Scene recognition and colorization for vehicle infrared images

    Science.gov (United States)

    Hou, Junjie; Sun, Shaoyuan; Shen, Zhenyi; Huang, Zhen; Zhao, Haitao

    2016-10-01

    In order to make better use of infrared technology for driving assistance system, a scene recognition and colorization method is proposed in this paper. Various objects in a queried infrared image are detected and labelled with proper categories by a combination of SIFT-Flow and MRF model. The queried image is then colorized by assigning corresponding colors according to the categories of the objects appeared. The results show that the strategy here emphasizes important information of the IR images for human vision and could be used to broaden the application of IR images for vehicle driving.

  10. New Approaches For Asteroid Spin State and Shape Modeling From Delay-Doppler Radar Images

    Science.gov (United States)

    Raissi, Chedy; Lamee, Mehdi; Mosiane, Olorato; Vassallo, Corinne; Busch, Michael W.; Greenberg, Adam; Benner, Lance A. M.; Naidu, Shantanu P.; Duong, Nicholas

    2016-10-01

    Delay-Doppler radar imaging is a powerful technique to characterize the trajectories, shapes, and spin states of near-Earth asteroids; and has yielded detailed models of dozens of objects. Reconstructing objects' shapes and spins from delay-Doppler data is a computationally intensive inversion problem. Since the 1990s, delay-Doppler data has been analyzed using the SHAPE software. SHAPE performs sequential single-parameter fitting, and requires considerable computer runtime and human intervention (Hudson 1993, Magri et al. 2007). Recently, multiple-parameter fitting algorithms have been shown to more efficiently invert delay-Doppler datasets (Greenberg & Margot 2015) - decreasing runtime while improving accuracy. However, extensive human oversight of the shape modeling process is still required. We have explored two new techniques to better automate delay-Doppler shape modeling: Bayesian optimization and a machine-learning neural network.One of the most time-intensive steps of the shape modeling process is to perform a grid search to constrain the target's spin state. We have implemented a Bayesian optimization routine that uses SHAPE to autonomously search the space of spin-state parameters. To test the efficacy of this technique, we compared it to results with human-guided SHAPE for asteroids 1992 UY4, 2000 RS11, and 2008 EV5. Bayesian optimization yielded similar spin state constraints within a factor of 3 less computer runtime.The shape modeling process could be further accelerated using a deep neural network to replace iterative fitting. We have implemented a neural network with a variational autoencoder (VAE), using a subset of known asteroid shapes and a large set of synthetic radar images as inputs to train the network. Conditioning the VAE in this manner allows the user to give the network a set of radar images and get a 3D shape model as an output. Additional development will be required to train a network to reliably render shapes from delay-Doppler

  11. Deep vein thrombosis of the lower limbs: A retrospective analysis of doppler ultrasound findings

    Directory of Open Access Journals (Sweden)

    Sanjay M Khaladkar

    2014-01-01

    Full Text Available Background: Deep venous thrombosis (DVT of lower limbs is one of the most common cause for the majority of deaths caused by pulmonary embolism. Many medical and surgical disorders are complicated by DVT. Most venous thrombi are clinically silent. B-mode and color Doppler imaging is needed for early diagnosis of DVT to prevent complications and sequalae of DVT. Aim and Objectives: The objectives of the following study were to evaluate the role of Doppler as an imaging modality in diagnosing DVT of lower limbs, to study the spectrum of findings on Doppler ultrasound in patients with DVT. Materials and Methods: Retrospective descriptive analysis of 78 patients of DVT diagnosed on Doppler. Results: Nearly 74% of the patients were males and 26% were females with majority belonging to fifth decade (26%. 75 (96.1% cases showed unilateral while 3 (3.9% cases showed bilateral lower limb involvement. In our study, predominant distribution of thrombus was found to be in above knee region with 69/78 (88.5% patients having thrombus in the superficial femoral vein. Popliteal vein was involved in 54/78 (69.2% patients. Complete thrombosis was observed in 54/78 (69% cases, while partial thrombosis was observed in 24/78 (31% cases. Subacute stage was seen in 42 cases (53.8%, acute stage in 23 cases (29.5% while chronic stage in 13 cases (16.7%. 71 cases (91% had multiple contiguous segmental involvement, whereas 7 cases (9% had isolated vein involvement. Conclusion: Color Doppler is useful in diagnosing DVT in symptomatic and at risk patients and provides a non-invasive method of investigation. It is also helpful in evaluating the site, extent and stage of thrombus.

  12. Real time 3D structural and Doppler OCT imaging on graphics processing units

    Science.gov (United States)

    Sylwestrzak, Marcin; Szlag, Daniel; Szkulmowski, Maciej; Gorczyńska, Iwona; Bukowska, Danuta; Wojtkowski, Maciej; Targowski, Piotr

    2013-03-01

    In this report the application of graphics processing unit (GPU) programming for real-time 3D Fourier domain Optical Coherence Tomography (FdOCT) imaging with implementation of Doppler algorithms for visualization of the flows in capillary vessels is presented. Generally, the time of the data processing of the FdOCT data on the main processor of the computer (CPU) constitute a main limitation for real-time imaging. Employing additional algorithms, such as Doppler OCT analysis, makes this processing even more time consuming. Lately developed GPUs, which offers a very high computational power, give a solution to this problem. Taking advantages of them for massively parallel data processing, allow for real-time imaging in FdOCT. The presented software for structural and Doppler OCT allow for the whole processing with visualization of 2D data consisting of 2000 A-scans generated from 2048 pixels spectra with frame rate about 120 fps. The 3D imaging in the same mode of the volume data build of 220 × 100 A-scans is performed at a rate of about 8 frames per second. In this paper a software architecture, organization of the threads and optimization applied is shown. For illustration the screen shots recorded during real time imaging of the phantom (homogeneous water solution of Intralipid in glass capillary) and the human eye in-vivo is presented.

  13. Comprasion of ovarian stromal blood flow measured by color Doppler ultrasonography in polycystic ovary syndrome patients and healthy women with ultrasonographic evidence of polycystic.

    Science.gov (United States)

    Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat

    2015-04-01

    To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p ovarian volumes were found significantly higher in patients with PCOS (p ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.

  14. Specialized Color Targets for Spectral Reflectance Reconstruction of Magnified Images

    Science.gov (United States)

    Kruschwitz, Jennifer D. T.

    Digital images are used almost exclusively instead of film to capture visual information across many scientific fields. The colorimetric color representation within these digital images can be relayed from the digital counts produced by the camera with the use of a known color target. In image capture of magnified images, there is currently no reliable color target that can be used at multiple magnifications and give the user a solid understanding of the color ground truth within those images. The first part of this dissertation included the design, fabrication, and testing of a color target produced with optical interference coated microlenses for use in an off-axis illumination, compound microscope. An ideal target was designed to increase the color gamut for colorimetric imaging and provide the necessary "Block Dye" spectral reflectance profiles across the visible spectrum to reduce the number of color patches necessary for multiple filter imaging systems that rely on statistical models for spectral reflectance reconstruction. There are other scientific disciplines that can benefit from a specialized color target to determine the color ground truth in their magnified images and perform spectral estimation. Not every discipline has the luxury of having a multi-filter imaging system. The second part of this dissertation developed two unique ways of using an interference coated color mirror target: one that relies on multiple light-source angles, and one that leverages a dynamic color change with time. The source multi-angle technique would be used for the microelectronic discipline where the reconstructed spectral reflectance would be used to determine a dielectric film thickness on a silicon substrate, and the time varying technique would be used for a biomedical example to determine the thickness of human tear film.

  15. Image mosaicking based on feature points using color-invariant values

    Science.gov (United States)

    Lee, Dong-Chang; Kwon, Oh-Seol; Ko, Kyung-Woo; Lee, Ho-Young; Ha, Yeong-Ho

    2008-02-01

    In the field of computer vision, image mosaicking is achieved using image features, such as textures, colors, and shapes between corresponding images, or local descriptors representing neighborhoods of feature points extracted from corresponding images. However, image mosaicking based on feature points has attracted more recent attention due to the simplicity of the geometric transformation, regardless of distortion and differences in intensity generated by camera motion in consecutive images. Yet, since most feature-point matching algorithms extract feature points using gray values, identifying corresponding points becomes difficult in the case of changing illumination and images with a similar intensity. Accordingly, to solve these problems, this paper proposes a method of image mosaicking based on feature points using color information of images. Essentially, the digital values acquired from a real digital color camera are converted to values of a virtual camera with distinct narrow bands. Values based on the surface reflectance and invariant to the chromaticity of various illuminations are then derived from the virtual camera values and defined as color-invariant values invariant to changing illuminations. The validity of these color-invariant values is verified in a test using a Macbeth Color-Checker under simulated illuminations. The test also compares the proposed method using the color-invariant values with the conventional SIFT algorithm. The accuracy of the matching between the feature points extracted using the proposed method is increased, while image mosaicking using color information is also achieved.

  16. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI...

  17. Low-frequency high-definition power Doppler in visualizing and defining fetal pulmonary venous connections.

    Science.gov (United States)

    Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong

    2014-07-01

    The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.

  18. An imaging colorimeter for noncontact tissue color mapping.

    Science.gov (United States)

    Balas, C

    1997-06-01

    There has been a considerable effort in several medical fields, for objective color analysis and characterization of biological tissues. Conventional colorimeters have proved inadequate for this purpose, since they do not provide spatial color information and because the measuring procedure randomly affects the color of the tissue. In this paper an imaging colorimeter is presented, where the nonimaging optical photodetector of colorimeters is replaced with the charge-coupled device (CCD) sensor of a color video camera, enabling the independent capturing of the color information for any spatial point within its field-of-view. Combining imaging and colorimetry methods, the acquired image is calibrated and corrected, under several ambient light conditions, providing noncontact reproducible color measurements and mapping, free of the errors and the limitations present in conventional colorimeters. This system was used for monitoring of blood supply changes of psoriatic plaques, that have undergone Psoralens and ultraviolet-A radiation (PUVA) therapy, where reproducible and reliable measurements were demonstrated. These features highlight the potential of the imaging colorimeters as clinical and research tools for the standardization of clinical diagnosis and for the objective evaluation of treatment effectiveness.

  19. Color and neighbor edge directional difference feature for image retrieval

    Institute of Scientific and Technical Information of China (English)

    Chaobing Huang; Shengsheng Yu; Jingli Zhou; Hongwei Lu

    2005-01-01

    @@ A novel image feature termed neighbor edge directional difference unit histogram is proposed, in which the neighbor edge directional difference unit is defined and computed for every pixel in the image, and is used to generate the neighbor edge directional difference unit histogram. This histogram and color histogram are used as feature indexes to retrieve color image. The feature is invariant to image scaling and translation and has more powerful descriptive for the natural color images. Experimental results show that the feature can achieve better retrieval performance than other color-spatial features.

  20. Color Histogram Diffusion for Image Enhancement

    Science.gov (United States)

    Kim, Taemin

    2011-01-01

    Various color histogram equalization (CHE) methods have been proposed to extend grayscale histogram equalization (GHE) for color images. In this paper a new method called histogram diffusion that extends the GHE method to arbitrary dimensions is proposed. Ranges in a histogram are specified as overlapping bars of uniform heights and variable widths which are proportional to their frequencies. This diagram is called the vistogram. As an alternative approach to GHE, the squared error of the vistogram from the uniform distribution is minimized. Each bar in the vistogram is approximated by a Gaussian function. Gaussian particles in the vistoram diffuse as a nonlinear autonomous system of ordinary differential equations. CHE results of color images showed that the approach is effective.

  1. Content-based image retrieval: Color-selection exploited

    NARCIS (Netherlands)

    Broek, E.L. van den; Vuurpijl, L.G.; Kisters, P. M. F.; Schmid, J.C.M. von; Moens, M.F.; Busser, R. de; Hiemstra, D.; Kraaij, W.

    2002-01-01

    This research presents a new color selection interface that facilitates query-by-color in Content-Based Image Retrieval (CBIR). Existing CBIR color selection interfaces, are being judged as non-intuitive and difficult to use. Our interface copes with these problems of usability. It is based on 11

  2. Content-Based Image Retrieval: Color-selection exploited

    NARCIS (Netherlands)

    Moens, Marie-Francine; van den Broek, Egon; Vuurpijl, L.G.; de Brusser, Rik; Kisters, P.M.F.; Hiemstra, Djoerd; Kraaij, Wessel; von Schmid, J.C.M.

    2002-01-01

    This research presents a new color selection interface that facilitates query-by-color in Content-Based Image Retrieval (CBIR). Existing CBIR color selection interfaces, are being judged as non-intuitive and difficult to use. Our interface copes with these problems of usability. It is based on 11

  3. Quaternion-based transformation for extraction of image-generating Doppler for ISAR

    CSIR Research Space (South Africa)

    Abdul Gaffar, MY

    2008-10-01

    Full Text Available contributing motion that is useful to the ISAR imaging process; the contributing motion consists of the Doppler generating axis and the effective angle of rotation. This letter presents a quaternion-based transformation that converts measured attitude...

  4. Tomographic Particle Image Velocimetry Using Colored Shadow Imaging

    KAUST Repository

    Alarfaj, Meshal K.

    2016-02-01

    Tomographic Particle Image Velocimetry Using Colored Shadow Imaging by Meshal K Alarfaj, Master of Science King Abdullah University of Science & Technology, 2015 Tomographic Particle image velocimetry (PIV) is a recent PIV method capable of reconstructing the full 3D velocity field of complex flows, within a 3-D volume. For nearly the last decade, it has become the most powerful tool for study of turbulent velocity fields and promises great advancements in the study of fluid mechanics. Among the early published studies, a good number of researches have suggested enhancements and optimizations of different aspects of this technique to improve the effectiveness. One major aspect, which is the core of the present work, is related to reducing the cost of the Tomographic PIV setup. In this thesis, we attempt to reduce this cost by using an experimental setup exploiting 4 commercial digital still cameras in combination with low-cost Light emitting diodes (LEDs). We use two different colors to distinguish the two light pulses. By using colored shadows with red and green LEDs, we can identify the particle locations within the measurement volume, at the two different times, thereby allowing calculation of the velocities. The present work tests this technique on the flows patterns of a jet ejected from a tube in a water tank. Results from the images processing are presented and challenges discussed.

  5. Color Multifocus Image Fusion Using Empirical Mode Decomposition

    Directory of Open Access Journals (Sweden)

    S. Savić

    2013-11-01

    Full Text Available In this paper, a recently proposed grayscale multifocus image fusion method based on the first level of Empirical Mode Decomposition (EMD has been extended to color images. In addition, this paper deals with low contrast multifocus image fusion. The major advantages of the proposed methods are simplicity, absence of artifacts and control of contrast, while this isn’t the case with other pyramidal multifocus fusion methods. The efficiency of the proposed method is tested subjectively and with a vector gradient based objective measure, that is proposed in this paper for multifocus color image fusion. Subjective analysis performed on a multifocus image dataset has shown its superiority to the existing EMD and DWT based methods. The objective measures of grayscale and color image fusion show significantly better scores for this method than for the classic complex EMD fusion method.

  6. Color Doppler imaging of the retrobulbar circulation and plasmatic biomarkers of vascular risk in age-related macular degeneration: A pilot study

    Directory of Open Access Journals (Sweden)

    Fermin Rodrigo

    2018-01-01

    Full Text Available Purpose: To evaluate preliminarily and compare the level of plasmatic biomarkers of vascular risk in patients with and without exudative age-related macular degeneration (ARMD and to relate it to vascular resistance alterations in the ophthalmic artery (OA, central retinal artery (CRA, posterior temporal ciliary artery (PTCA, and posterior nasal ciliary artery (PNCA. Methods: Color Doppler imaging of the OA, CRA, PTCA, and PNCA was performed in 30 eyes of 30 cataract patients (control group as well as in 30 eyes of 30 patients with naive exudative ARMD (study group, measuring the peak systolic velocity, end-diastolic velocity (EDV, and Pourcelot resistive index (RI. Likewise, in both groups, a blood test was performed to determine the plasmatic levels of homocysteine, C-reactive protein (CRP, B12 vitamin, and folic acid. Results: A positive and significant correlation was found between the level of CRP and RI of the OA in the ARMD group (r = 0.498, P = 0.005, with an increased RI in all arteries compared to controls, although differences only reached statistical significance for the PTCA (P = 0.035. Likewise, a significantly lower EDV for the CRA was found in ARMD eyes compared to controls (P = 0.041. In the study group, significantly higher plasmatic levels of homocysteine (P = 0.042 and CRP (P = 0.046 were found. In contrast, no significant differences were found between groups in the levels of folic acid (P = 0.265 and B12 vitamin (P = 0.520. Conclusion: The decrease of the choroidal perfusion related to hyperhomocysteinemia, and increase in the CRP plasmatic levels may play an etiological role on the exudative ARMD. This should be investigated in future studies with larger samples of patients.

  7. Development of multi-color scintillator based X-ray image intensifier

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Konagai, Chikara; Noji, Takashi

    2004-01-01

    A multi-color scintillator based high-sensitive, wide dynamic range and long-life X-ray image intensifier has been developed. An europium activated Y 2 O 2 S scintillator, emitting red, green and blue photons of different intensities, is utilized as the output fluorescent screen of the intensifier. By combining this image intensifier with a suitably tuned high sensitive color CCD camera, it is possible for a sensitivity of the red color component to become six times higher than that of the conventional image intensifier. Simultaneous emission of a moderate green color and a weak blue color covers different sensitivity regions. This widens the dynamic range, by nearly two orders of ten. With this image intensifier, it is possible to image simultaneously complex objects containing various different X-ray transmission from paper, water or plastic to heavy metals. This high sensitivity intensifier, operated at lower X-ray exposure, causes less degradation of scintillator materials and less colorization of output screen glass, and thus helps achieve a longer lifetime. This color scintillator based image intensifier is being introduced for X-ray inspection in various fields

  8. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    OpenAIRE

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 ...

  9. Color quality improvement of reconstructed images in color digital holography using speckle method and spectral estimation

    Science.gov (United States)

    Funamizu, Hideki; Onodera, Yusei; Aizu, Yoshihisa

    2018-05-01

    In this study, we report color quality improvement of reconstructed images in color digital holography using the speckle method and the spectral estimation. In this technique, an object is illuminated by a speckle field and then an object wave is produced, while a plane wave is used as a reference wave. For three wavelengths, the interference patterns of two coherent waves are recorded as digital holograms on an image sensor. Speckle fields are changed by moving a ground glass plate in an in-plane direction, and a number of holograms are acquired to average the reconstructed images. After the averaging process of images reconstructed from multiple holograms, we use the Wiener estimation method for obtaining spectral transmittance curves in reconstructed images. The color reproducibility in this method is demonstrated and evaluated using a Macbeth color chart film and staining cells of onion.

  10. Preparing Colorful Astronomical Images and Illustrations

    Science.gov (United States)

    Levay, Z. G.; Frattare, L. M.

    2001-12-01

    We present techniques for using mainstream graphics software, specifically Adobe Photoshop and Illustrator, for producing composite color images and illustrations from astronomical data. These techniques have been used with numerous images from the Hubble Space Telescope to produce printed and web-based news, education and public presentation products as well as illustrations for technical publication. While Photoshop is not intended for quantitative analysis of full dynamic range data (as are IRAF or IDL, for example), we have had much success applying Photoshop's numerous, versatile tools to work with scaled images, masks, text and graphics in multiple semi-transparent layers and channels. These features, along with its user-oriented, visual interface, provide convenient tools to produce high-quality, full-color images and graphics for printed and on-line publication and presentation.

  11. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  12. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    International Nuclear Information System (INIS)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo; Kim, Jung Sik

    2002-01-01

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  13. Research on image complexity evaluation method based on color information

    Science.gov (United States)

    Wang, Hao; Duan, Jin; Han, Xue-hui; Xiao, Bo

    2017-11-01

    In order to evaluate the complexity of a color image more effectively and find the connection between image complexity and image information, this paper presents a method to compute the complexity of image based on color information.Under the complexity ,the theoretical analysis first divides the complexity from the subjective level, divides into three levels: low complexity, medium complexity and high complexity, and then carries on the image feature extraction, finally establishes the function between the complexity value and the color characteristic model. The experimental results show that this kind of evaluation method can objectively reconstruct the complexity of the image from the image feature research. The experimental results obtained by the method of this paper are in good agreement with the results of human visual perception complexity,Color image complexity has a certain reference value.

  14. [Elective lymph node dissection in malignant melanoma--status of color Doppler findings].

    Science.gov (United States)

    Omlor, G; Dill-Müller, D; Gross, G; Kautz, G; Schüder, G; Zaun, H; Feifel, G

    1996-01-01

    Since there is still a controversial discussion about the ELND in melanoma patients, the purpose of this prospective study was to optimize the indication concerning ELND by ultrasound examinations. 144 patients with primary melanomas were checked every 3 months after excision. Echomorphologic pattern and intranodal vascularisation in the color-flow Doppler modus provide essential information for differential diagnosis. We found 47 patients (32.6%) with suspicious ultrasound lesions. 50% of these patients had no pathological clinical findings, the histological findings of excised lymph nodes were positive in all cases. It must be emphasized, however, that the group with lymph node metastases included 12 patients with low-risk-melanomas (2 x Tis, 10 x T1 historical control group (141 patients), where ELND was performed routinely in high-risk-patients ( > T2), the incidence of ELND in our hospital decreased more than 50%; at the same time the percentage of detected lymph node metastases increased (twice).

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of colors to show the speed and direction of blood ...

  16. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Lee, Myoung Seok; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup; Park, Joong Shin; Jun, Jong Kwan

    2017-01-01

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP

  17. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok [Dept. of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Joong Shin; Jun, Jong Kwan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP.

  18. Finding text in color images

    Science.gov (United States)

    Zhou, Jiangying; Lopresti, Daniel P.; Tasdizen, Tolga

    1998-04-01

    In this paper, we consider the problem of locating and extracting text from WWW images. A previous algorithm based on color clustering and connected components analysis works well as long as the color of each character is relatively uniform and the typography is fairly simple. It breaks down quickly, however, when these assumptions are violated. In this paper, we describe more robust techniques for dealing with this challenging problem. We present an improved color clustering algorithm that measures similarity based on both RGB and spatial proximity. Layout analysis is also incorporated to handle more complex typography. THese changes significantly enhance the performance of our text detection procedure.

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... or kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of colors to show the speed and direction of blood flow through a blood vessel. Power Doppler is a newer technique that is more ...

  20. Multifractal analysis of three-dimensional histogram from color images

    International Nuclear Information System (INIS)

    Chauveau, Julien; Rousseau, David; Richard, Paul; Chapeau-Blondeau, Francois

    2010-01-01

    Natural images, especially color or multicomponent images, are complex information-carrying signals. To contribute to the characterization of this complexity, we investigate the possibility of multiscale organization in the colorimetric structure of natural images. This is realized by means of a multifractal analysis applied to the three-dimensional histogram from natural color images. The observed behaviors are confronted to those of reference models with known multifractal properties. We use for this purpose synthetic random images with trivial monofractal behavior, and multidimensional multiplicative cascades known for their actual multifractal behavior. The behaviors observed on natural images exhibit similarities with those of the multifractal multiplicative cascades and display the signature of elaborate multiscale organizations stemming from the histograms of natural color images. This type of characterization of colorimetric properties can be helpful to various tasks of digital image processing, as for instance modeling, classification, indexing.

  1. Color reproduction and processing algorithm based on real-time mapping for endoscopic images.

    Science.gov (United States)

    Khan, Tareq H; Mohammed, Shahed K; Imtiaz, Mohammad S; Wahid, Khan A

    2016-01-01

    In this paper, we present a real-time preprocessing algorithm for image enhancement for endoscopic images. A novel dictionary based color mapping algorithm is used for reproducing the color information from a theme image. The theme image is selected from a nearby anatomical location. A database of color endoscopy image for different location is prepared for this purpose. The color map is dynamic as its contents change with the change of the theme image. This method is used on low contrast grayscale white light images and raw narrow band images to highlight the vascular and mucosa structures and to colorize the images. It can also be applied to enhance the tone of color images. The statistic visual representation and universal image quality measures show that the proposed method can highlight the mucosa structure compared to other methods. The color similarity has been verified using Delta E color difference, structure similarity index, mean structure similarity index and structure and hue similarity. The color enhancement was measured using color enhancement factor that shows considerable improvements. The proposed algorithm has low and linear time complexity, which results in higher execution speed than other related works.

  2. Estimation of color modification in digital images by CFA pattern change.

    Science.gov (United States)

    Choi, Chang-Hee; Lee, Hae-Yeoun; Lee, Heung-Kyu

    2013-03-10

    Extensive studies have been carried out for detecting image forgery such as copy-move, re-sampling, blurring, and contrast enhancement. Although color modification is a common forgery technique, there is no reported forensic method for detecting this type of manipulation. In this paper, we propose a novel algorithm for estimating color modification in images acquired from digital cameras when the images are modified. Most commercial digital cameras are equipped with a color filter array (CFA) for acquiring the color information of each pixel. As a result, the images acquired from such digital cameras include a trace from the CFA pattern. This pattern is composed of the basic red green blue (RGB) colors, and it is changed when color modification is carried out on the image. We designed an advanced intermediate value counting method for measuring the change in the CFA pattern and estimating the extent of color modification. The proposed method is verified experimentally by using 10,366 test images. The results confirmed the ability of the proposed method to estimate color modification with high accuracy. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Pyshnyi, Michael Ph. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation); Kuznetsov, Oleg A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)], E-mail: kuznetsov_oa@yahoo.com; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)

    2009-05-15

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  4. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    International Nuclear Information System (INIS)

    Pyshnyi, Michael Ph.; Kuznetsov, Oleg A.; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A.

    2009-01-01

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  5. [Pilot study of echocardiographic studies using color- and pulsed-wave spectral Doppler methods in blue-crowned amazons (Amazona ventralis) and blue-fronted amazons (Amazona a. aestiva)].

    Science.gov (United States)

    Pees, M; Straub, J; Schumacher, J; Gompf, R; Krautwald-Junghanns, M E

    2005-02-01

    Colour-flow and pulsed-wave spectral Doppler echocardiography was performed on 6 healthy, adult Hispaniolan amazon parrots (Amazona ventralis) and 6 blue-fronted amazon parrots (Amazona a. aestiva) to establish normal reference values. Birds were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. An electrocardiogram was recorded continuously and birds were imaged with a micro-phased-array scanner with a frequency of 7.0 MHz. After assessment of cardiac function in 2-D-echocardiography, blood flow across the left and the right atrioventricular valve and across the aortic valve was determined using color-flow and pulsed-wave spectral Doppler echocardiography. Diastolic inflow (mean value +/- standard deviation) into the left ventricle was 0.17 +/- 0.02 m/s (Hispaniolan amazons) and 0.18 +/- 0.03 m/s (Blue fronted amazons). Diastolic inflow into the right ventricle was 0.22 +/- 0.05 m/s (Hispaniolan amazons) and 0.22 +/- 0.04 m/s (Blue fronted amazons). Velocity across the aortic valve was 0.84 +/- 0.07 m/s (Hispaniolan amazons) and 0.83 +/- 0.08 m/s (Blue fronted amazons). Systolic pulmonary flow could not be detected in any of the birds in this study. No significant differences were evident between the two species examined. Results of this study indicate that Doppler echocardiography is a promising technique to determine blood flow in the avian heart. Further studies in other avian species are needed to establish reference values for assessment of cardiac function in diseased birds.

  6. Hypercholesterolemia and Myocardial function evaluated via Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Kotaru Pavan

    2009-11-01

    Full Text Available Abstract Objective To establish a link between hypercholesterolemia and myocardial dysfunction. Background Heart failure is a complex disease involving changes in systolic and diastolic function. Newer echocardiographic imaging modalities may be able to detect discreet changes in myocardial function associated with hypercholesterolemia. Therefore we sought to establish a link between hypercholesterolemia and myocardial dysfunction with tissue Doppler imaging (TDI. Methods Twenty-seven rabbits were studied: 7 were fed normal chow (group 1 and 20 a high cholesterol diet (10 with ezetimibe, 1 mg/kg/day; group 2 and 10 without, group 3. Echocardiographic images were obtained under general anesthesia. Serum cholesterol levels were obtained at baseline, 3 and 6 months and myocardial cholesterol levels measured following euthanasia. Results Doppler measurements, including E/A, E'/A' and S' were significantly lower in group 3 compared to both groups 1 and 2 but no significant differences were noted in chamber sizes or ejection fraction among the groups. Average serum cholesterol was higher in group 3 compared to groups 1 and 2 respectively (495 ± 305 mg/dl vs. 114 ± 95 mg/dl and 87 ± 37 mg/dl; p 2 = 0.17 p = 0.04, r2 = 0.37 p = 0.001 and r2 = 0.24 p = 0.01. Conclusion Cholesterol load in the serum and myocardium was significantly associated with decreased systolic and diastolic function by TDI. Moreover, lipid lowering was protective.

  7. FNTD radiation dosimetry system enhanced with dual-color wide-field imaging

    International Nuclear Information System (INIS)

    Akselrod, M.S.; Fomenko, V.V.; Bartz, J.A.; Ding, F.

    2014-01-01

    At high neutron and photon doses Fluorescent Nuclear Track Detectors (FNTDs) require operation in analog mode and the measurement results depend on individual crystal color center concentration (coloration). We describe a new method for radiation dosimetry using FNTDs, which includes non-destructive, automatic sensitivity calibration for each individual FNTD. In the method presented, confocal laser scanning fluorescent imaging of FNTDs is combined with dual-color wide field imaging of the FNTD. The calibration is achieved by measuring the color center concentration in the detector through fluorescence imaging and reducing the effect of diffuse reflection on the lapped surface of the FNTD by imaging with infra-red (IR) light. The dual-color imaging of FNTDs is shown to provide a good estimation of the detector sensitivity at high doses of photons and neutrons, where conventional track counting is impeded by track overlap. - Highlights: • New method and optical imaging head was developed for FNTD used at high doses. • Dual-color wide-field imaging used for color center concentration measurement. • Green fluorescence corrected by diffuse reflection used for sensitivity correction. • FNTD dose measurements performed in analog processing mode

  8. Tissue Doppler Imaging in the evaluation of abdominal aortic pulsatility: a useful tool for the neonatologist.

    Science.gov (United States)

    Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo

    2017-03-01

    Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.

  9. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  10. Color in Image and Video Processing: Most Recent Trends and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Tominaga Shoji

    2008-01-01

    Full Text Available Abstract The motivation of this paper is to provide an overview of the most recent trends and of the future research directions in color image and video processing. Rather than covering all aspects of the domain this survey covers issues related to the most active research areas in the last two years. It presents the most recent trends as well as the state-of-the-art, with a broad survey of the relevant literature, in the main active research areas in color imaging. It also focuses on the most promising research areas in color imaging science. This survey gives an overview about the issues, controversies, and problems of color image science. It focuses on human color vision, perception, and interpretation. It focuses also on acquisition systems, consumer imaging applications, and medical imaging applications. Next it gives a brief overview about the solutions, recommendations, most recent trends, and future trends of color image science. It focuses on color space, appearance models, color difference metrics, and color saliency. It focuses also on color features, color-based object tracking, scene illuminant estimation and color constancy, quality assessment and fidelity assessment, color characterization and calibration of a display device. It focuses on quantization, filtering and enhancement, segmentation, coding and compression, watermarking, and lastly on multispectral color image processing. Lastly, it addresses the research areas which still need addressing and which are the next and future perspectives of color in image and video processing.

  11. Color in Image and Video Processing: Most Recent Trends and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Konstantinos N. Plataniotis

    2008-05-01

    Full Text Available The motivation of this paper is to provide an overview of the most recent trends and of the future research directions in color image and video processing. Rather than covering all aspects of the domain this survey covers issues related to the most active research areas in the last two years. It presents the most recent trends as well as the state-of-the-art, with a broad survey of the relevant literature, in the main active research areas in color imaging. It also focuses on the most promising research areas in color imaging science. This survey gives an overview about the issues, controversies, and problems of color image science. It focuses on human color vision, perception, and interpretation. It focuses also on acquisition systems, consumer imaging applications, and medical imaging applications. Next it gives a brief overview about the solutions, recommendations, most recent trends, and future trends of color image science. It focuses on color space, appearance models, color difference metrics, and color saliency. It focuses also on color features, color-based object tracking, scene illuminant estimation and color constancy, quality assessment and fidelity assessment, color characterization and calibration of a display device. It focuses on quantization, filtering and enhancement, segmentation, coding and compression, watermarking, and lastly on multispectral color image processing. Lastly, it addresses the research areas which still need addressing and which are the next and future perspectives of color in image and video processing.

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Color Doppler uses a computer to convert Doppler measurements into an array of colors to show the ... in some situations. Spectral Doppler displays blood flow measurements graphically, in terms of the distance traveled per ...

  13. Emerging from Water: Underwater Image Color Correction Based on Weakly Supervised Color Transfer

    OpenAIRE

    Li, Chongyi; Guo, Jichang; Guo, Chunle

    2017-01-01

    Underwater vision suffers from severe effects due to selective attenuation and scattering when light propagates through water. Such degradation not only affects the quality of underwater images but limits the ability of vision tasks. Different from existing methods which either ignore the wavelength dependency of the attenuation or assume a specific spectral profile, we tackle color distortion problem of underwater image from a new view. In this letter, we propose a weakly supervised color tr...

  14. Exploring the use of memory colors for image enhancement

    Science.gov (United States)

    Xue, Su; Tan, Minghui; McNamara, Ann; Dorsey, Julie; Rushmeier, Holly

    2014-02-01

    Memory colors refer to those colors recalled in association with familiar objects. While some previous work introduces this concept to assist digital image enhancement, their basis, i.e., on-screen memory colors, are not appropriately investigated. In addition, the resulting adjustment methods developed are not evaluated from a perceptual view of point. In this paper, we first perform a context-free perceptual experiment to establish the overall distributions of screen memory colors for three pervasive objects. Then, we use a context-based experiment to locate the most representative memory colors; at the same time, we investigate the interactions of memory colors between different objects. Finally, we show a simple yet effective application using representative memory colors to enhance digital images. A user study is performed to evaluate the performance of our technique.

  15. Information system for administrating and distributing color images through internet

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available The information system for administrating and distributing color images through the Internet ensures the consistent replication of color images, their storage - in an on-line data base - and predictable distribution, by means of a digitally distributed flow, based on Windows platform and POD (Print On Demand technology. The consistent replication of color images inde-pendently from the parameters of the processing equipment and from the features of the programs composing the technological flow, is ensured by the standard color management sys-tem defined by ICC (International Color Consortium, which is integrated by the Windows operation system and by the POD technology. The latter minimize the noticeable differences between the colors captured, displayed or printed by various replication equipments and/or edited by various graphical applications. The system integrated web application ensures the uploading of the color images in an on-line database and their administration and distribution among the users via the Internet. For the preservation of the data expressed by the color im-ages during their transfer along a digitally distributed flow, the software application includes an original tool ensuring the accurate replication of colors on computer displays or when printing them by means of various color printers or presses. For development and use, this application employs a hardware platform based on PC support and a competitive software platform, based on: the Windows operation system, the .NET. Development medium and the C# programming language. This information system is beneficial for creators and users of color images, the success of the printed or on-line (Internet publications depending on the sizeable, predictable and accurate replication of colors employed for the visual expression of information in every activity fields of the modern society. The herein introduced information system enables all interested persons to access the

  16. Doppler time-of-flight imaging

    KAUST Repository

    Heidrich, Wolfgang

    2017-02-16

    Systems and methods for imaging object velocity are provided. In an embodiment, at least one Time-of-Flight camera is used to capture a signal representative of an object in motion over an exposure time. Illumination and modulation frequency of the captured motion are coded within the exposure time. A change of illumination frequency is mapped to measured pixel intensities of the captured motion within the exposure time, and information about a Doppler shift in the illumination frequency is extracted to obtain a measurement of instantaneous per pixel velocity of the object in motion. The radial velocity information of the object in motion can be simultaneously captured for each pixel captured within the exposure time. In one or more aspects, the illumination frequency can be coded orthogonal to the modulation frequency of the captured motion. The change of illumination frequency can correspond to radial object velocity.

  17. Formation of radiation images using photographic color film

    International Nuclear Information System (INIS)

    Kuge, Ken'ichi; Kobayashi, Takaharu; Hasegawa, Akira; Yasuda, Nakahiro; Kumagai, Hiroshi

    2001-01-01

    A new method to reveal the three-dimensional information of nuclear tracks in a nuclear emulsion layer was developed by the use of color photography. The tracks were represented with a color image in which different depths were indicated by different colors, and the three-dimensional information was obtained from color changes. We present the procedure for a self-made photographic coating and the development formula that can represent the color tracks clearly. (author)

  18. Perceptual quality of color images of natural scenes transformed in CIELUV color space

    NARCIS (Netherlands)

    Fedorovskaya, E.A.; Blommaert, F.J.J.; Ridder, de H.; Eschbach, R.; Braun, K.

    1997-01-01

    Transformations of digitized color images in perceptually-uniform CIELUV color space and their perceptual relevance were investigated. Chroma veriation was chosen as the first step of a series of investigations into possible transformations (including lightness, hue-angle, chroma, ect.) To obtain

  19. Perceptual quality of color images of natural scenes transformed in CIELUV color space

    NARCIS (Netherlands)

    Fedorovskaya, E.A.; Blommaert, F.J.J.; Ridder, de H.

    1993-01-01

    Transformations of digitized color images in perceptually-uniform CIELUV color space and their perceptual relevance were investigated. Chroma variation was chosen as the first step of a series of investigations into possible transformations (including lightness, hue-angle, chroma, etc.). To obtain

  20. Multispectral Imaging of Meat Quality - Color and Texture

    DEFF Research Database (Denmark)

    Trinderup, Camilla Himmelstrup

    transformations to the CIELAB color space, the common color space within food science. The results show that meat color assessment with a multispectral imaging is a great alternative to the traditional colorimeter, i.e. the vision system meets some of the limitations that the colorimeter possesses. To mention one...

  1. Segmentation of color images by chromaticity features using self-organizing maps

    Directory of Open Access Journals (Sweden)

    Farid García-Lamont

    2016-05-01

    Full Text Available Usually, the segmentation of color images is performed using cluster-based methods and the RGB space to represent the colors. The drawback with these methods is the a priori knowledge of the number of groups, or colors, in the image; besides, the RGB space issensitive to the intensity of the colors. Humans can identify different sections within a scene by the chromaticity of its colors of, as this is the feature humans employ to tell them apart. In this paper, we propose to emulate the human perception of color by training a self-organizing map (SOM with samples of chromaticity of different colors. The image to process is mapped to the HSV space because in this space the chromaticity is decoupled from the intensity, while in the RGB space this is not possible. Our proposal does not require knowing a priori the number of colors within a scene, and non-uniform illumination does not significantly affect the image segmentation. We present experimental results using some images from the Berkeley segmentation database by employing SOMs with different sizes, which are segmented successfully using only chromaticity features.

  2. Spatio-spectral color filter array design for optimal image recovery.

    Science.gov (United States)

    Hirakawa, Keigo; Wolfe, Patrick J

    2008-10-01

    In digital imaging applications, data are typically obtained via a spatial subsampling procedure implemented as a color filter array-a physical construction whereby only a single color value is measured at each pixel location. Owing to the growing ubiquity of color imaging and display devices, much recent work has focused on the implications of such arrays for subsequent digital processing, including in particular the canonical demosaicking task of reconstructing a full color image from spatially subsampled and incomplete color data acquired under a particular choice of array pattern. In contrast to the majority of the demosaicking literature, we consider here the problem of color filter array design and its implications for spatial reconstruction quality. We pose this problem formally as one of simultaneously maximizing the spectral radii of luminance and chrominance channels subject to perfect reconstruction, and-after proving sub-optimality of a wide class of existing array patterns-provide a constructive method for its solution that yields robust, new panchromatic designs implementable as subtractive colors. Empirical evaluations on multiple color image test sets support our theoretical results, and indicate the potential of these patterns to increase spatial resolution for fixed sensor size, and to contribute to improved reconstruction fidelity as well as significantly reduced hardware complexity.

  3. Color image quality in projection displays: a case study

    Science.gov (United States)

    Strand, Monica; Hardeberg, Jon Y.; Nussbaum, Peter

    2005-01-01

    Recently the use of projection displays has increased dramatically in different applications such as digital cinema, home theatre, and business and educational presentations. Even if the color image quality of these devices has improved significantly over the years, it is still a common situation for users of projection displays that the projected colors differ significantly from the intended ones. This study presented in this paper attempts to analyze the color image quality of a large set of projection display devices, particularly investigating the variations in color reproduction. As a case study, a set of 14 projectors (LCD and DLP technology) at Gjovik University College have been tested under four different conditions: dark and light room, with and without using an ICC-profile. To find out more about the importance of the illumination conditions in a room, and the degree of improvement when using an ICC-profile, the results from the measurements was processed and analyzed. Eye-One Beamer from GretagMacbeth was used to make the profiles. The color image quality was evaluated both visually and by color difference calculations. The results from the analysis indicated large visual and colorimetric differences between the projectors. Our DLP projectors have generally smaller color gamut than LCD projectors. The color gamuts of older projectors are significantly smaller than that of newer ones. The amount of ambient light reaching the screen is of great importance for the visual impression. If too much reflections and other ambient light reaches the screen, the projected image gets pale and has low contrast. When using a profile, the differences in colors between the projectors gets smaller and the colors appears more correct. For one device, the average ΔE*ab color difference when compared to a relative white reference was reduced from 22 to 11, for another from 13 to 6. Blue colors have the largest variations among the projection displays and makes them

  4. Align and conquer: moving toward plug-and-play color imaging

    Science.gov (United States)

    Lee, Ho J.

    1996-03-01

    The rapid evolution of the low-cost color printing and image capture markets has precipitated a huge increase in the use of color imagery by casual end users on desktop systems, as opposed to traditional professional color users working with specialized equipment. While the cost of color equipment and software has decreased dramatically, the underlying system-level problems associated with color reproduction have remained the same, and in many cases are more difficult to address in a casual environment than in a professional setting. The proliferation of color imaging technologies so far has resulted in a wide availability of component solutions which work together poorly. A similar situation in the desktop computing market has led to the various `Plug-and-Play' standards, which provide a degree of interoperability between a range of products on disparate computing platforms. This presentation will discuss some of the underlying issues and emerging trends in the desktop and consumer digital color imaging markets.

  5. Color image enhancement of medical images using alpha-rooting and zonal alpha-rooting methods on 2D QDFT

    Science.gov (United States)

    Grigoryan, Artyom M.; John, Aparna; Agaian, Sos S.

    2017-03-01

    2-D quaternion discrete Fourier transform (2-D QDFT) is the Fourier transform applied to color images when the color images are considered in the quaternion space. The quaternion numbers are four dimensional hyper-complex numbers. Quaternion representation of color image allows us to see the color of the image as a single unit. In quaternion approach of color image enhancement, each color is seen as a vector. This permits us to see the merging effect of the color due to the combination of the primary colors. The color images are used to be processed by applying the respective algorithm onto each channels separately, and then, composing the color image from the processed channels. In this article, the alpha-rooting and zonal alpha-rooting methods are used with the 2-D QDFT. In the alpha-rooting method, the alpha-root of the transformed frequency values of the 2-D QDFT are determined before taking the inverse transform. In the zonal alpha-rooting method, the frequency spectrum of the 2-D QDFT is divided by different zones and the alpha-rooting is applied with different alpha values for different zones. The optimization of the choice of alpha values is done with the genetic algorithm. The visual perception of 3-D medical images is increased by changing the reference gray line.

  6. A Simple Encryption Algorithm for Quantum Color Image

    Science.gov (United States)

    Li, Panchi; Zhao, Ya

    2017-06-01

    In this paper, a simple encryption scheme for quantum color image is proposed. Firstly, a color image is transformed into a quantum superposition state by employing NEQR (novel enhanced quantum representation), where the R,G,B values of every pixel in a 24-bit RGB true color image are represented by 24 single-qubit basic states, and each value has 8 qubits. Then, these 24 qubits are respectively transformed from a basic state into a balanced superposition state by employed the controlled rotation gates. At this time, the gray-scale values of R, G, B of every pixel are in a balanced superposition of 224 multi-qubits basic states. After measuring, the whole image is an uniform white noise, which does not provide any information. Decryption is the reverse process of encryption. The experimental results on the classical computer show that the proposed encryption scheme has better security.

  7. Single Lens Dual-Aperture 3D Imaging System: Color Modeling

    Science.gov (United States)

    Bae, Sam Y.; Korniski, Ronald; Ream, Allen; Fritz, Eric; Shearn, Michael

    2012-01-01

    In an effort to miniaturize a 3D imaging system, we created two viewpoints in a single objective lens camera. This was accomplished by placing a pair of Complementary Multi-band Bandpass Filters (CMBFs) in the aperture area. Two key characteristics about the CMBFs are that the passbands are staggered so only one viewpoint is opened at a time when a light band matched to that passband is illuminated, and the passbands are positioned throughout the visible spectrum, so each viewpoint can render color by taking RGB spectral images. Each viewpoint takes a different spectral image from the other viewpoint hence yielding a different color image relative to the other. This color mismatch in the two viewpoints could lead to color rivalry, where the human vision system fails to resolve two different colors. The difference will be closer if the number of passbands in a CMBF increases. (However, the number of passbands is constrained by cost and fabrication technique.) In this paper, simulation predicting the color mismatch is reported.

  8. Screening for stroke in sickle cell anemia: comparison of transcranial Doppler imaging and nonimaging US techniques.

    Science.gov (United States)

    Neish, Ariane S; Blews, David E; Simms, Catherine A; Merritt, Robert K; Spinks, Alice J

    2002-03-01

    To determine whether criteria for screening patients with sickle cell anemia for stroke established with a nonimaging transcranial Doppler ultrasonographic (US) technique are applicable to studies performed with a transcranial Doppler US imaging technique. One hundred sixty-eight examinations in 66 children were performed for sickle cell stroke screening. Children were examined with nonimaging and imaging transcranial Doppler US techniques on the same day, for a total of 84 paired examinations. The time-averaged maximum mean velocity (V(mean)) and resistive index (RI) were calculated in the middle cerebral arteries, bifurcations of the distal internal carotid arteries, distal internal carotid arteries, anterior cerebral arteries, posterior cerebral arteries, and basilar arteries. The maximum systolic velocity (V(max)) was evaluated in the distal internal carotid arteries and middle cerebral arteries. V(mean), V(max), and RI measurements were subjected to repeated-measures multivariate analysis of covariance, and the Pearson product moment correlation was used for middle cerebral artery velocity, age, and hemoglobin. V(mean) measurements obtained with nonimaging and imaging techniques varied substantially for the bifurcation of the distal internal carotid artery, the posterior cerebral artery, and the basilar artery. Substantial differences were found in RIs for every vessel. Examination time was shorter with the nonimaging technique. V(mean) measurements in the middle cerebral artery, distal internal carotid artery, and anterior cerebral artery did not vary substantially between nonimaging and imaging transcranial Doppler US. RI data did not yield comparable measurements.

  9. Image quality evaluation of medical color and monochrome displays using an imaging colorimeter

    Science.gov (United States)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2012-10-01

    The purpose of this presentation is to demonstrate the means which permit examining the accuracy of Image Quality with respect to MTF (Modulation Transfer Function) and NPS (Noise Power Spectrum) of Color Displays and Monochrome Displays. Indications were in the past that color displays could affect the clinical performance of color displays negatively compared to monochrome displays. Now colorimeters like the PM-1423 are available which have higher sensitivity and color accuracy than the traditional cameras like CCD cameras. Reference (1) was not based on measurements made with a colorimeter. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future SPIE Conference.Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. This paper focuses on the measurements of physical characteristics of the spatial resolution and noise performance of color and monochrome medical displays which were made with a colorimeter and we will after this meeting submit the data to an ROC study so we have again a paper to present at a future Annual SPIE Conference. Specifically, Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) were evaluated and compared at different digital driving levels (DDL) between the two medical displays. The Imaging Colorimeter. Measurement of color image quality needs were done with an imaging colorimeter as it is shown below. Imaging colorimetry is ideally suited to FPD measurement because imaging systems capture spatial data generating millions of data points in a single measurement operation. The imaging colorimeter which was used was the PM-1423 from Radiant Imaging. It uses

  10. A method to validate quantitative high-frequency power doppler ultrasound with fluorescence in vivo video microscopy.

    Science.gov (United States)

    Pinter, Stephen Z; Kim, Dae-Ro; Hague, M Nicole; Chambers, Ann F; MacDonald, Ian C; Lacefield, James C

    2014-08-01

    Flow quantification with high-frequency (>20 MHz) power Doppler ultrasound can be performed objectively using the wall-filter selection curve (WFSC) method to select the cutoff velocity that yields a best-estimate color pixel density (CPD). An in vivo video microscopy system (IVVM) is combined with high-frequency power Doppler ultrasound to provide a method for validation of CPD measurements based on WFSCs in mouse testicular vessels. The ultrasound and IVVM systems are instrumented so that the mouse remains on the same imaging platform when switching between the two modalities. In vivo video microscopy provides gold-standard measurements of vascular diameter to validate power Doppler CPD estimates. Measurements in four image planes from three mice exhibit wide variation in the optimal cutoff velocity and indicate that a predetermined cutoff velocity setting can introduce significant errors in studies intended to quantify vascularity. Consistent with previously published flow-phantom data, in vivo WFSCs exhibited three characteristic regions and detectable plateaus. Selection of a cutoff velocity at the right end of the plateau yielded a CPD close to the gold-standard vascular volume fraction estimated using IVVM. An investigator can implement the WFSC method to help adapt cutoff velocity to current blood flow conditions and thereby improve the accuracy of power Doppler for quantitative microvascular imaging. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Use of discrete chromatic space to tune the image tone in a color image mosaic

    Science.gov (United States)

    Zhang, Zuxun; Li, Zhijiang; Zhang, Jianqing; Zheng, Li

    2003-09-01

    Color image process is a very important problem. However, the main approach presently of them is to transfer RGB colour space into another colour space, such as HIS (Hue, Intensity and Saturation). YIQ, LUV and so on. Virutally, it may not be a valid way to process colour airborne image just in one colour space. Because the electromagnetic wave is physically altered in every wave band, while the color image is perceived based on psychology vision. Therefore, it's necessary to propose an approach accord with physical transformation and psychological perception. Then, an analysis on how to use relative colour spaces to process colour airborne photo is discussed and an application on how to tune the image tone in colour airborne image mosaic is introduced. As a practice, a complete approach to perform the mosaic on color airborne images via taking full advantage of relative color spaces is discussed in the application.

  12. The structure and properties of color spaces and the representation of color images

    CERN Document Server

    Dubois, Eric

    2009-01-01

    This lecture describes the author's approach to the representation of color spaces and their use for color image processing. The lecture starts with a precise formulation of the space of physical stimuli (light). The model includes both continuous spectra and monochromatic spectra in the form of Dirac deltas. The spectral densities are considered to be functions of a continuous wavelength variable. This leads into the formulation of color space as a three-dimensional vector space, with all the associated structure. The approach is to start with the axioms of color matching for normal human vie

  13. Munsell color analysis of Landsat color-ratio-composite images of limonitic areas in southwest New Mexico

    Science.gov (United States)

    Kruse, F. A.

    1985-01-01

    The causes of color variations in the green areas on Landsat 4/5-4/6-6/7 (red-blue-green) color-ratio-composite (CRC) images, defined as limonitic areas, were investigated by analyzing the CRC images of the Lordsburg, New Mexico area. The red-blue-green additive color system was mathematically transformed into the cylindrical Munsell color coordinates (hue, saturation, and value), and selected areas were digitally analyzed for color variation. The obtained precise color characteristics were then correlated with properties of surface material. The amount of limonite (L) visible to the sensor was found to be the primary cause of the observed color differences. The visible L is, is turn, affected by the amount of L on the material's surface and by within-pixel mixing of limonitic and nonlimonitic materials. The secondary cause of variation was vegetation density, which shifted CRC hues towards yellow-green, decreased saturation, and increased value.

  14. Perivesical varices and portal hypertension: imaging study

    International Nuclear Information System (INIS)

    Mallorquin Jimenez, F.; Medina Benitez, A.; Lopez Machado, E.; Pardo Moreno, M.D.; Garrido Moreno, C.; Pastor Rull, J.

    1995-01-01

    Nine patients with portal hypertension syndrome and Perivesical varices are studied retrospectively by means of imaging techniques including ultrasound, duplex Doppler, color Doppler, CT and angiography. All the patients presented portal thrombosis and thickening of the bladder wall. These collaterals either represent a shunting of hepato pedal flow or correspond to blood stasis associated with said syndrome. Ultrasound, whether involving duplex Doppler or color Doppler techniques, is highly useful to detect the presence of Perivesical varices which appear as tubular or rounded hypo echogenic areas in the bladder wall. Given the association of this entity with bladder wall thickening, it should be taken into account in any clinical situation involving said change, especially in patients with portal hypertension; moreover knowledge of its presence is of great importance when the possibility of creating shunts by means of interventional or surgical vascular procedures or other types of abdominal procedures are being considered because of the risk of bleeding. (Author)

  15. Region-Based Color Image Indexing and Retrieval

    DEFF Research Database (Denmark)

    Kompatsiaris, Ioannis; Triantafyllou, Evangelia; Strintzis, Michael G.

    2001-01-01

    In this paper a region-based color image indexing and retrieval algorithm is presented. As a basis for the indexing, a novel K-Means segmentation algorithm is used, modified so as to take into account the coherence of the regions. A new color distance is also defined for this algorithm. Based on ....... Experimental results demonstrate the performance of the algorithm. The development of an intelligent image content-based search engine for the World Wide Web is also presented, as a direct application of the presented algorithm....

  16. Using color histogram normalization for recovering chromatic illumination-changed images.

    Science.gov (United States)

    Pei, S C; Tseng, C L; Wu, C C

    2001-11-01

    We propose a novel image-recovery method using the covariance matrix of the red-green-blue (R-G-B) color histogram and tensor theories. The image-recovery method is called the color histogram normalization algorithm. It is known that the color histograms of an image taken under varied illuminations are related by a general affine transformation of the R-G-B coordinates when the illumination is changed. We propose a simplified affine model for application with illumination variation. This simplified affine model considers the effects of only three basic forms of distortion: translation, scaling, and rotation. According to this principle, we can estimate the affine transformation matrix necessary to recover images whose color distributions are varied as a result of illumination changes. We compare the normalized color histogram of the standard image with that of the tested image. By performing some operations of simple linear algebra, we can estimate the matrix of the affine transformation between two images under different illuminations. To demonstrate the performance of the proposed algorithm, we divide the experiments into two parts: computer-simulated images and real images corresponding to illumination changes. Simulation results show that the proposed algorithm is effective for both types of images. We also explain the noise-sensitive skew-rotation estimation that exists in the general affine model and demonstrate that the proposed simplified affine model without the use of skew rotation is better than the general affine model for such applications.

  17. Unsupervised color image segmentation using a lattice algebra clustering technique

    Science.gov (United States)

    Urcid, Gonzalo; Ritter, Gerhard X.

    2011-08-01

    In this paper we introduce a lattice algebra clustering technique for segmenting digital images in the Red-Green- Blue (RGB) color space. The proposed technique is a two step procedure. Given an input color image, the first step determines the finite set of its extreme pixel vectors within the color cube by means of the scaled min-W and max-M lattice auto-associative memory matrices, including the minimum and maximum vector bounds. In the second step, maximal rectangular boxes enclosing each extreme color pixel are found using the Chebychev distance between color pixels; afterwards, clustering is performed by assigning each image pixel to its corresponding maximal box. The two steps in our proposed method are completely unsupervised or autonomous. Illustrative examples are provided to demonstrate the color segmentation results including a brief numerical comparison with two other non-maximal variations of the same clustering technique.

  18. Cardiac Time Intervals Measured by Tissue Doppler Imaging M-mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Schnohr, Peter

    2016-01-01

    function was evaluated in 1915 participants by using both conventional echocardiography and tissue Doppler imaging (TDI). The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT), and ejection time (ET), were obtained by TDI M-mode through the mitral......). Additionally, they displayed a significant dose-response relationship, between increasing severity of elevated blood pressure and increasing left ventricular mass index (P

  19. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  20. Naturalness and image quality : saturation and lightness variation in color images of natural scenes

    NARCIS (Netherlands)

    Ridder, de H.

    1996-01-01

    The relation between perceived image quality and naturalness was investigated by varying the colorfulness of natural images at various lightness levels. At each lightness level, subjects assessed perceived colorfulness, naturalness, and quality as a function of average saturation by means of direct

  1. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow

    Science.gov (United States)

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-01

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s-1, for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L

  2. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow.

    Science.gov (United States)

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-09

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s -1 , for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L

  3. Availability of color calibration for consistent color display in medical images and optimization of reference brightness for clinical use

    Science.gov (United States)

    Iwai, Daiki; Suganami, Haruka; Hosoba, Minoru; Ohno, Kazuko; Emoto, Yutaka; Tabata, Yoshito; Matsui, Norihisa

    2013-03-01

    Color image consistency has not been accomplished yet except the Digital Imaging and Communication in Medicine (DICOM) Supplement 100 for implementing a color reproduction pipeline and device independent color spaces. Thus, most healthcare enterprises could not check monitor degradation routinely. To ensure color consistency in medical color imaging, monitor color calibration should be introduced. Using simple color calibration device . chromaticity of colors including typical color (Red, Green, Blue, Green and White) are measured as device independent profile connection space value called u'v' before and after calibration. In addition, clinical color images are displayed and visual differences are observed. In color calibration, monitor brightness level has to be set to quite lower value 80 cd/m2 according to sRGB standard. As Maximum brightness of most color monitors available currently for medical use have much higher brightness than 80 cd/m2, it is not seemed to be appropriate to use 80 cd/m2 level for calibration. Therefore, we propose that new brightness standard should be introduced while maintaining the color representation in clinical use. To evaluate effects of brightness to chromaticity experimentally, brightness level is changed in two monitors from 80 to 270cd/m2 and chromaticity value are compared with each brightness levels. As a result, there are no significant differences in chromaticity diagram when brightness levels are changed. In conclusion, chromaticity is close to theoretical value after color calibration. Moreover, chromaticity isn't moved when brightness is changed. The results indicate optimized reference brightness level for clinical use could be set at high brightness in current monitors .

  4. A novel quantum steganography scheme for color images

    Science.gov (United States)

    Li, Panchi; Liu, Xiande

    In quantum image steganography, embedding capacity and security are two important issues. This paper presents a novel quantum steganography scheme using color images as cover images. First, the secret information is divided into 3-bit segments, and then each 3-bit segment is embedded into the LSB of one color pixel in the cover image according to its own value and using Gray code mapping rules. Extraction is the inverse of embedding. We designed the quantum circuits that implement the embedding and extracting process. The simulation results on a classical computer show that the proposed scheme outperforms several other existing schemes in terms of embedding capacity and security.

  5. A Hybrid DWT-SVD Image-Coding System (HDWTSVD for Color Images

    Directory of Open Access Journals (Sweden)

    Humberto Ochoa

    2003-04-01

    Full Text Available In this paper, we propose the HDWTSVD system to encode color images. Before encoding, the color components (RGB are transformed into YCbCr. Cb and Cr components are downsampled by a factor of two, both horizontally and vertically, before sending them through the encoder. A criterion based on the average standard deviation of 8x8 subblocks of the Y component is used to choose DWT or SVD for all the components. Standard test images are compressed based on the proposed algorithm.

  6. Superimpose of images by appending two simple video amplifier circuits to color television

    International Nuclear Information System (INIS)

    Kojima, Kazuhiko; Hiraki, Tatsunosuke; Koshida, Kichiro; Maekawa, Ryuichi; Hisada, Kinichi.

    1979-01-01

    Images are very useful to obtain diagnostic informations in medical fields. Also by superimposing two or three images obtained from the same patient, various informations, for example a degree of overlapping and anatomical land mark, which can not be found in only one image, can be often found. In this paper characteristics of our trial color television system for the purpose of superimposing x-ray images and/or radionuclide images are described. This color television system superimposing two images in each different color consists of two monochromatic vidicon cameras and 20 inches conventional color television in which only two simple video amplifier circuits are added. Signals from vidicon cameras are amplified about 40 dB and are directly applied to cathode terminals of color CRT in the television. This system is very simple and economical color displays, and enhance a degree of overlapping and displacement between images. As one of typical clinical applications, pancreas images were superimposed in color by this method. As a result, size and position of pancreas was enhanced. Also x-ray image and radionuclide image were superimposed to find exactly the position of tumors. Furthermore this system was very useful for color display of multinuclides scintigraphy. (author)

  7. Superimpose of images by appending two simple video amplifier circuits to color television

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, K; Hiraki, T; Koshida, K; Maekawa, R [Kanazawa Univ. (Japan). School of Paramedicine; Hisada, K

    1979-09-01

    Images are very useful to obtain diagnostic informations in medical fields. Also by superimposing two or three images obtained from the same patient, various informations, for example a degree of overlapping and anatomical land mark, which can not be found in only one image, can be often found. In this paper characteristics of our trial color television system for the purpose of superimposing x-ray images and/or radionuclide images are described. This color television system superimposing two images in each different color consists of two monochromatic vidicon cameras and 20 inches conventional color television in which only two simple video amplifier circuits are added. Signals from vidicon cameras are amplified about 40 dB and are directly applied to cathode terminals of color CRT in the television. This system is very simple and economical color displays, and enhance a degree of overlapping and displacement between images. As one of typical clinical applications, pancreas images were superimposed in color by this method. As a result, size and position of pancreas was enhanced. Also x-ray image and radionuclide image were superimposed to find exactly the position of tumors. Furthermore this system was very useful for color display of multinuclides scintigraphy.

  8. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    Science.gov (United States)

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation. PMID:25505135

  9. Cost-effectiveness of laser Doppler imaging in burn care in the Netherlands

    NARCIS (Netherlands)

    M.J. Hop (M. Jenda); J. Hiddingh (J.); C.M. Stekelenburg (C.); H.C. Kuipers (Hester); E. Middelkoop (Esther); M. Nieuwenhuis (Marianne); S. Polinder (Suzanne); M.E. van Baar (Margriet)

    2013-01-01

    textabstractBackground: Early accurate assessment of burn depth is important to determine the optimal treatment of burns. The method most used to determine burn depth is clinical assessment, which is the least expensive, but not the most accurate.Laser Doppler imaging (LDI) is a technique with which

  10. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  11. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  12. Hybridizing Differential Evolution with a Genetic Algorithm for Color Image Segmentation

    Directory of Open Access Journals (Sweden)

    R. V. V. Krishna

    2016-10-01

    Full Text Available This paper proposes a hybrid of differential evolution and genetic algorithms to solve the color image segmentation problem. Clustering based color image segmentation algorithms segment an image by clustering the features of color and texture, thereby obtaining accurate prototype cluster centers. In the proposed algorithm, the color features are obtained using the homogeneity model. A new texture feature named Power Law Descriptor (PLD which is a modification of Weber Local Descriptor (WLD is proposed and further used as a texture feature for clustering. Genetic algorithms are competent in handling binary variables, while differential evolution on the other hand is more efficient in handling real parameters. The obtained texture feature is binary in nature and the color feature is a real value, which suits very well the hybrid cluster center optimization problem in image segmentation. Thus in the proposed algorithm, the optimum texture feature centers are evolved using genetic algorithms, whereas the optimum color feature centers are evolved using differential evolution.

  13. Demonstration of blood flow by color doppler in the femoral artery distal to arterial cannula during peripheral venoarterial-extracorporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    K G Suresh Rao

    2017-01-01

    Full Text Available In spite of distal perfusion of the limb using a cannula, the limb can have ischemic events if there is an undetected kink or clot anywhere in the line or thrombus in the artery. There are several ways to monitor and assess the limb ischemia. Monitoring for clinical signs of limb ischemia like temperature change and pallor is reliable and mandatory. We report a method where we used color Doppler to document the blood flow. Curvilinear vascular probe of an echo machine is used to identify the flow in the distal femoral artery of the lower limb. . As we have demonstrated in the video attached, once flow to the distal limb perfusion system is shut off by closing the three way stop cock, we can appreciate the immediate cessation of flow in the artery by Doppler.

  14. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    Science.gov (United States)

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  15. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    Directory of Open Access Journals (Sweden)

    Michelle Kutzler

    2011-01-01

    Full Text Available We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV was higher in fertile males compared to infertile males (P=0.0004. In addition, end diastolic velocity (EDV within the supratesticular arteries was higher for fertile males when compared to infertile males (P=0.0325. Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P=0.0104. However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P=0.121. In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P=0.486 and marginal arteries (P=0.144. The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  16. Characterization of benign and malignant solid breast masses in harmonic 3D power Doppler imaging

    International Nuclear Information System (INIS)

    Hsiao, Y.-H.; Huang, Y.-L.; Kuo, S.-J.; Liang, W.-M.; Chen, S.-T.; Chen, D.-R.

    2009-01-01

    Purpose: The authors assessed the characteristics of benign and malignant solid breast tumors in harmonic three-dimensional (3D) power Doppler imaging and proposed decision models to classify benign and malignant breast tumors. Materials and methods: A total of 86 malignant and 97 benign harmonic 3D power Doppler US images were analyzed. All the harmonic 3D power Doppler images were obtained using a Voluson730 US system (GE, Zipf, Austria) equipped with a RSP 6-12 transducer and tissue harmonic imaging modalities. Imaging analysis was performed using the Virtual Organ Computer-aided Analysis (VOCAL)-imaging program. Histogram indices, the vascularization index (VI), flow index (FI) and vascularization-flow index (VFI), were calculated for the intra-tumor and for shells with an outside thickness of 3 mm surrounding the breast tumors. The receiver operating characteristic (ROC) curves were calculated to estimate the diagnostic performances. Results: The results revealed that the choice of decision model comprised the parameters of patient age, intra-tumor VI, and tumor volume to classify benign and malignant breast tumors. The area under the ROC curve (Az) was 0.910, accuracy was 81.4%, and sensitivity and specificity were 81.4% and 81.4%, respectively. The parameter intra-tumor VI was the choice for all of the histogram indices in differentiating between malignant and benign lesions. Conclusion: The decision model, which was composed of patient age, tumor volume and intra-tumor VI, and a cut-off value for intra-tumor VI at the upper end of patient age and tumor volume, was recommended in clinical application.

  17. Color-Image Classification Using MRFs for an Outdoor Mobile Robot

    Directory of Open Access Journals (Sweden)

    Moises Alencastre-Miranda

    2005-02-01

    Full Text Available In this paper, we suggest to use color-image classification (in several phases using Markov Random Fields (MRFs in order to understand natural images from outdoor environment's scenes for a mobile robot. We skip preprocessing phase having same results and better performance. In segmentation phase, we implement a color segmentation method considering I3 color space measure average in little image's cells obtained from a single split step. In classification phase, a MRF was used to identify regions as one of three selected classes; here, we consider at the same time the intrinsic color features of the image and the neighborhood system between image's cells. Finally, we use region growing and contextual information to correct misclassification errors. We have implemented and tested those phases with several images taken at our campus' gardens. We include some results in off-line processing mode and in on-line execution mode on an outdoor mobile robot. The vision system has been used for reactive exploration in an outdoor environment.

  18. Research on Methods of Infrared and Color Image Fusion Based on Wavelet Transform

    Directory of Open Access Journals (Sweden)

    Zhao Rentao

    2014-06-01

    Full Text Available There is significant difference in the imaging features of infrared image and color image, but their fusion images also have very good complementary information. In this paper, based on the characteristics of infrared image and color image, first of all, wavelet transform is applied to the luminance component of the infrared image and color image. In multi resolution the relevant regional variance is regarded as the activity measure, relevant regional variance ratio as the matching measure, and the fusion image is enhanced in the process of integration, thus getting the fused images by final synthesis module and multi-resolution inverse transform. The experimental results show that the fusion image obtained by the method proposed in this paper is better than the other methods in keeping the useful information of the original infrared image and the color information of the original color image. In addition, the fusion image has stronger adaptability and better visual effect.

  19. Cost-effectiveness of laser Doppler imaging in burn care in the Netherlands

    NARCIS (Netherlands)

    Hop, M.J.; Hiddingh, J.; Stekelenburg, C.; Kuipers, H.C.; Middelkoop, E.; Nieuwenhuis, M.K.; Polinder, S.; van Baar, M.E.

    2013-01-01

    Background: Early accurate assessment of burn depth is important to determine the optimal treatment of burns. The method most used to determine burn depth is clinical assessment, which is the least expensive, but not the most accurate.Laser Doppler imaging (LDI) is a technique with which a more

  20. Color image definition evaluation method based on deep learning method

    Science.gov (United States)

    Liu, Di; Li, YingChun

    2018-01-01

    In order to evaluate different blurring levels of color image and improve the method of image definition evaluation, this paper proposed a method based on the depth learning framework and BP neural network classification model, and presents a non-reference color image clarity evaluation method. Firstly, using VGG16 net as the feature extractor to extract 4,096 dimensions features of the images, then the extracted features and labeled images are employed in BP neural network to train. And finally achieve the color image definition evaluation. The method in this paper are experimented by using images from the CSIQ database. The images are blurred at different levels. There are 4,000 images after the processing. Dividing the 4,000 images into three categories, each category represents a blur level. 300 out of 400 high-dimensional features are trained in VGG16 net and BP neural network, and the rest of 100 samples are tested. The experimental results show that the method can take full advantage of the learning and characterization capability of deep learning. Referring to the current shortcomings of the major existing image clarity evaluation methods, which manually design and extract features. The method in this paper can extract the images features automatically, and has got excellent image quality classification accuracy for the test data set. The accuracy rate is 96%. Moreover, the predicted quality levels of original color images are similar to the perception of the human visual system.

  1. A Color Image Watermarking Scheme Resistant against Geometrical Attacks

    Directory of Open Access Journals (Sweden)

    Y. Xing

    2010-04-01

    Full Text Available The geometrical attacks are still a problem for many digital watermarking algorithms at present. In this paper, we propose a watermarking algorithm for color images resistant to geometrical distortions (rotation and scaling. The singular value decomposition is used for watermark embedding and extraction. The log-polar map- ping (LPM and phase correlation method are used to register the position of geometrical distortion suffered by the watermarked image. Experiments with different kinds of color images and watermarks demonstrate that the watermarking algorithm is robust to common image processing attacks, especially geometrical attacks.

  2. Single underwater image enhancement based on color cast removal and visibility restoration

    Science.gov (United States)

    Li, Chongyi; Guo, Jichang; Wang, Bo; Cong, Runmin; Zhang, Yan; Wang, Jian

    2016-05-01

    Images taken under underwater condition usually have color cast and serious loss of contrast and visibility. Degraded underwater images are inconvenient for observation and analysis. In order to address these problems, an underwater image-enhancement method is proposed. A simple yet effective underwater image color cast removal algorithm is first presented based on the optimization theory. Then, based on the minimum information loss principle and inherent relationship of medium transmission maps of three color channels in an underwater image, an effective visibility restoration algorithm is proposed to recover visibility, contrast, and natural appearance of degraded underwater images. To evaluate the performance of the proposed method, qualitative comparison, quantitative comparison, and color accuracy test are conducted. Experimental results demonstrate that the proposed method can effectively remove color cast, improve contrast and visibility, and recover natural appearance of degraded underwater images. Additionally, the proposed method is comparable to and even better than several state-of-the-art methods.

  3. Segmentation and Classification of Burn Color Images

    Science.gov (United States)

    2001-10-25

    SEGMENTATION AND CLASSIFICATION OF BURN COLOR IMAGES Begoña Acha1, Carmen Serrano1, Laura Roa2 1Área de Teoría de la Señal y Comunicaciones ...2000, Las Vegas (USA), pp. 411-415. [21] G. Wyszecki and W.S. Stiles, Color Science: Concepts and Methods, Quantitative Data and Formulae (New

  4. Segmentation and Classification of Burn Color Images

    National Research Council Canada - National Science Library

    Acha, Begonya

    2001-01-01

    .... In the classification part, we take advantage of color information by clustering, with a vector quantization algorithm, the color centroids of small squares, taken from the burnt segmented part of the image, in the (V1, V2) plane into two possible groups, where V1 and V2 are the two chrominance components of the CIE Lab representation.

  5. FUSION SEGMENTATION METHOD BASED ON FUZZY THEORY FOR COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    J. Zhao

    2017-09-01

    Full Text Available The image segmentation method based on two-dimensional histogram segments the image according to the thresholds of the intensity of the target pixel and the average intensity of its neighborhood. This method is essentially a hard-decision method. Due to the uncertainties when labeling the pixels around the threshold, the hard-decision method can easily get the wrong segmentation result. Therefore, a fusion segmentation method based on fuzzy theory is proposed in this paper. We use membership function to model the uncertainties on each color channel of the color image. Then, we segment the color image according to the fuzzy reasoning. The experiment results show that our proposed method can get better segmentation results both on the natural scene images and optical remote sensing images compared with the traditional thresholding method. The fusion method in this paper can provide new ideas for the information extraction of optical remote sensing images and polarization SAR images.

  6. Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems.

    Science.gov (United States)

    Buck, Thomas; Hwang, Shawn M; Plicht, Björn; Mucci, Ronald A; Hunold, Peter; Erbel, Raimund; Levine, Robert A

    2008-06-01

    Cardiac ultrasound imaging systems are limited in the noninvasive quantification of valvular regurgitation due to indirect measurements and inaccurate hemodynamic assumptions. We recently demonstrated that the principle of integration of backscattered acoustic Doppler power times velocity can be used for flow quantification in valvular regurgitation directly at the vena contracta of a regurgitant flow jet. We now aimed to accomplish implementation of automated Doppler power flow analysis software on a standard cardiac ultrasound system utilizing novel matrix-array transducer technology with detailed description of system requirements, components and software contributing to the system. This system based on a 3.5 MHz, matrix-array cardiac ultrasound scanner (Sonos 5500, Philips Medical Systems) was validated by means of comprehensive experimental signal generator trials, in vitro flow phantom trials and in vivo testing in 48 patients with mitral regurgitation of different severity and etiology using magnetic resonance imaging (MRI) for reference. All measurements displayed good correlation to the reference values, indicating successful implementation of automated Doppler power flow analysis on a matrix-array ultrasound imaging system. Systematic underestimation of effective regurgitant orifice areas >0.65 cm(2) and volumes >40 ml was found due to currently limited Doppler beam width that could be readily overcome by the use of new generation 2D matrix-array technology. Automated flow quantification in valvular heart disease based on backscattered Doppler power can be fully implemented on board a routinely used matrix-array ultrasound imaging systems. Such automated Doppler power flow analysis of valvular regurgitant flow directly, noninvasively, and user independent overcomes the practical limitations of current techniques.

  7. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  8. Adaptive pseudo-color enhancement method of weld radiographic images based on HSI color space and self-transformation of pixels

    Science.gov (United States)

    Jiang, Hongquan; Zhao, Yalin; Gao, Jianmin; Gao, Zhiyong

    2017-06-01

    The radiographic testing (RT) image of a steam turbine manufacturing enterprise has the characteristics of low gray level, low contrast, and blurriness, which lead to a substandard image quality. Moreover, it is not conducive for human eyes to detect and evaluate defects. This study proposes an adaptive pseudo-color enhancement method for weld radiographic images based on the hue, saturation, and intensity (HSI) color space and the self-transformation of pixels to solve these problems. First, the pixel's self-transformation is performed to the pixel value of the original RT image. The function value after the pixel's self-transformation is assigned to the HSI components in the HSI color space. Thereafter, the average intensity of the enhanced image is adaptively adjusted to 0.5 according to the intensity of the original image. Moreover, the hue range and interval can be adjusted according to personal habits. Finally, the HSI components after the adaptive adjustment can be transformed to display in the red, green, and blue color space. Numerous weld radiographic images from a steam turbine manufacturing enterprise are used to validate the proposed method. The experimental results show that the proposed pseudo-color enhancement method can improve image definition and make the target and background areas distinct in weld radiographic images. The enhanced images will be more conducive for defect recognition. Moreover, the image enhanced using the proposed method conforms to the human eye visual properties, and the effectiveness of defect recognition and evaluation can be ensured.

  9. Adaptive pseudo-color enhancement method of weld radiographic images based on HSI color space and self-transformation of pixels.

    Science.gov (United States)

    Jiang, Hongquan; Zhao, Yalin; Gao, Jianmin; Gao, Zhiyong

    2017-06-01

    The radiographic testing (RT) image of a steam turbine manufacturing enterprise has the characteristics of low gray level, low contrast, and blurriness, which lead to a substandard image quality. Moreover, it is not conducive for human eyes to detect and evaluate defects. This study proposes an adaptive pseudo-color enhancement method for weld radiographic images based on the hue, saturation, and intensity (HSI) color space and the self-transformation of pixels to solve these problems. First, the pixel's self-transformation is performed to the pixel value of the original RT image. The function value after the pixel's self-transformation is assigned to the HSI components in the HSI color space. Thereafter, the average intensity of the enhanced image is adaptively adjusted to 0.5 according to the intensity of the original image. Moreover, the hue range and interval can be adjusted according to personal habits. Finally, the HSI components after the adaptive adjustment can be transformed to display in the red, green, and blue color space. Numerous weld radiographic images from a steam turbine manufacturing enterprise are used to validate the proposed method. The experimental results show that the proposed pseudo-color enhancement method can improve image definition and make the target and background areas distinct in weld radiographic images. The enhanced images will be more conducive for defect recognition. Moreover, the image enhanced using the proposed method conforms to the human eye visual properties, and the effectiveness of defect recognition and evaluation can be ensured.

  10. INTEGRATION OF SPATIAL INFORMATION WITH COLOR FOR CONTENT RETRIEVAL OF REMOTE SENSING IMAGES

    Directory of Open Access Journals (Sweden)

    Bikesh Kumar Singh

    2010-08-01

    Full Text Available There is rapid increase in image databases of remote sensing images due to image satellites with high resolution, commercial applications of remote sensing & high available bandwidth in last few years. The problem of content-based image retrieval (CBIR of remotely sensed images presents a major challenge not only because of the surprisingly increasing volume of images acquired from a wide range of sensors but also because of the complexity of images themselves. In this paper, a software system for content-based retrieval of remote sensing images using RGB and HSV color spaces is presented. Further, we also compare our results with spatiogram based content retrieval which integrates spatial information along with color histogram. Experimental results show that the integration of spatial information in color improves the image analysis of remote sensing data. In general, retrievals in HSV color space showed better performance than in RGB color space.

  11. Content-based quality evaluation of color images: overview and proposals

    Science.gov (United States)

    Tremeau, Alain; Richard, Noel; Colantoni, Philippe; Fernandez-Maloigne, Christine

    2003-12-01

    The automatic prediction of perceived quality from image data in general, and the assessment of particular image characteristics or attributes that may need improvement in particular, becomes an increasingly important part of intelligent imaging systems. The purpose of this paper is to propose to the color imaging community in general to develop a software package available on internet to help the user to select among all these approaches which is better appropriated to a given application. The ultimate goal of this project is to propose, next to implement, an open and unified color imaging system to set up a favourable context for the evaluation and analysis of color imaging processes. Many different methods for measuring the performance of a process have been proposed by different researchers. In this paper, we will discuss the advantages and shortcomings of most of main analysis criteria and performance measures currently used. The aim is not to establish a harsh competition between algorithms or processes, but rather to test and compare the efficiency of methodologies firstly to highlight strengths and weaknesses of a given algorithm or methodology on a given image type and secondly to have these results publicly available. This paper is focused on two important unsolved problems. Why it is so difficult to select a color space which gives better results than another one? Why it is so difficult to select an image quality metric which gives better results than another one, with respect to the judgment of the Human Visual System? Several methods used either in color imaging or in image quality will be thus discussed. Proposals for content-based image measures and means of developing a standard test suite for will be then presented. The above reference advocates for an evaluation protocol based on an automated procedure. This is the ultimate goal of our proposal.

  12. 'Focal thyroid inferno' on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xianshui, E-mail: fuxs1968@163.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Guo, Limei, E-mail: guolimei@bjmu.edu.cn [Department of Pathology, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Zhang, Huabin, E-mail: huabinzhang@bjmu.edu.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Ran, Weiqiang, E-mail: ranwq-sina@vip.sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Fu, Peng, E-mail: fupeng01@gmail.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Li, Zhiqiang, E-mail: lizhq126@126.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Chen, Wen, E-mail: wendy7989@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jiang, Ling, E-mail: papayaling@yahoo.com.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jia, Jianwen, E-mail: drjia88@sohu.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China)

    2012-11-15

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The {chi}{sup 2} test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using 'focal thyroid inferno' as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of 'focal thyroid inferno' is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  13. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  14. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  15. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  16. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  17. A fast color image enhancement algorithm based on Max Intensity Channel

    Science.gov (United States)

    Sun, Wei; Han, Long; Guo, Baolong; Jia, Wenyan; Sun, Mingui

    2014-03-01

    In this paper, we extend image enhancement techniques based on the retinex theory imitating human visual perception of scenes containing high illumination variations. This extension achieves simultaneous dynamic range modification, color consistency, and lightness rendition without multi-scale Gaussian filtering which has a certain halo effect. The reflection component is analyzed based on the illumination and reflection imaging model. A new prior named Max Intensity Channel (MIC) is implemented assuming that the reflections of some points in the scene are very high in at least one color channel. Using this prior, the illumination of the scene is obtained directly by performing a gray-scale closing operation and a fast cross-bilateral filtering on the MIC of the input color image. Consequently, the reflection component of each RGB color channel can be determined from the illumination and reflection imaging model. The proposed algorithm estimates the illumination component which is relatively smooth and maintains the edge details in different regions. A satisfactory color rendition is achieved for a class of images that do not satisfy the gray-world assumption implicit to the theoretical foundation of the retinex. Experiments are carried out to compare the new method with several spatial and transform domain methods. Our results indicate that the new method is superior in enhancement applications, improves computation speed, and performs well for images with high illumination variations than other methods. Further comparisons of images from National Aeronautics and Space Administration and a wearable camera eButton have shown a high performance of the new method with better color restoration and preservation of image details.

  18. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  19. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  20. Using color and grayscale images to teach histology to color-deficient medical students.

    Science.gov (United States)

    Rubin, Lindsay R; Lackey, Wendy L; Kennedy, Frances A; Stephenson, Robert B

    2009-01-01

    Examination of histologic and histopathologic microscopic sections relies upon differential colors provided by staining techniques, such as hematoxylin and eosin, to delineate normal tissue components and to identify pathologic alterations in these components. Given the prevalence of color deficiency (commonly called "color blindness") in the general population, it is likely that this reliance upon color differentiation poses a significant obstacle for several medical students beginning a course of study that includes examination of histologic slides. In the past, first-year medical students at Michigan State University who identified themselves as color deficient were encouraged to use color transparency overlays or tinted contact lenses to filter out problematic colors. Recently, however, we have offered such students a computer monitor adjusted to grayscale for in-lab work, as well as grayscale copies of color photomicrographs for examination purposes. Grayscale images emphasize the texture of tissues and the contrasts between tissues as the students learn histologic architecture. Using this approach, color-deficient students have quickly learned to compensate for their deficiency by focusing on cell and tissue structure rather than on color variation. Based upon our experience with color-deficient students, we believe that grayscale photomicrographs may also prove instructional for students with normal (trichromatic) color vision, by encouraging them to consider structural characteristics of cells and tissues that may otherwise be overshadowed by stain colors.

  1. A natural-color mapping for single-band night-time image based on FPGA

    Science.gov (United States)

    Wang, Yilun; Qian, Yunsheng

    2018-01-01

    A natural-color mapping for single-band night-time image method based on FPGA can transmit the color of the reference image to single-band night-time image, which is consistent with human visual habits and can help observers identify the target. This paper introduces the processing of the natural-color mapping algorithm based on FPGA. Firstly, the image can be transformed based on histogram equalization, and the intensity features and standard deviation features of reference image are stored in SRAM. Then, the real-time digital images' intensity features and standard deviation features are calculated by FPGA. At last, FPGA completes the color mapping through matching pixels between images using the features in luminance channel.

  2. A locally adaptive algorithm for shadow correction in color images

    Science.gov (United States)

    Karnaukhov, Victor; Kober, Vitaly

    2017-09-01

    The paper deals with correction of color images distorted by spatially nonuniform illumination. A serious distortion occurs in real conditions when a part of the scene containing 3D objects close to a directed light source is illuminated much brighter than the rest of the scene. A locally-adaptive algorithm for correction of shadow regions in color images is proposed. The algorithm consists of segmentation of shadow areas with rank-order statistics followed by correction of nonuniform illumination with human visual perception approach. The performance of the proposed algorithm is compared to that of common algorithms for correction of color images containing shadow regions.

  3. Lingual thyroid: value of integrated imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giovagnorio, F. [Sezione di Radiologia e Diagnostica per Immagini, Dipt. di Medicina Sperimentale e Patologia, Univ. `La Sapienza`, Rome (Italy); Cordier, A. [Ist. di Clinica Otorinolaringoiatrica, Univ. `La Sapienza`, Rome (Italy); Romeo, R. [Ist. di Clinica Otorinolaringoiatrica, Univ. `La Sapienza`, Rome (Italy)

    1996-02-01

    Lingual thyroid is an uncommon cause of oropharyngeal mass, due to a congential anomaly of thyroidal development and migration: It is defined precisely as the presence of thyroid tissue in the midline of the tongue base between circumvallatae papilae and the epiglottis. We report a case of lignual thyroid in which the integration of clinical data, sonography, color-duplex Doppler, MRI and scintigraphy was determinant in demonstrating the disease. A 22-year-old woman presented with a sensation of foreign body in the throat, dysphonia, dyspnoea and dysphagia; we performed sonography (7.5 MHz linear probe), color Doppler (7 MHz Doppler frequeny, PRF 3500 Hz) and MRI (1.5 T, spin-echo T1- and T2-weighted images with administration of Gd-DTPA); a scan with {sup 123}I demonstrated a relevant uptake at the base of the tongue, but no uptake at the typical thyroid location. The gland was removed and partially transplanted in the strap muscles of the neck. (orig.)

  4. Lingual thyroid: value of integrated imaging

    International Nuclear Information System (INIS)

    Giovagnorio, F.; Cordier, A.; Romeo, R.

    1996-01-01

    Lingual thyroid is an uncommon cause of oropharyngeal mass, due to a congential anomaly of thyroidal development and migration: It is defined precisely as the presence of thyroid tissue in the midline of the tongue base between circumvallatae papilae and the epiglottis. We report a case of lignual thyroid in which the integration of clinical data, sonography, color-duplex Doppler, MRI and scintigraphy was determinant in demonstrating the disease. A 22-year-old woman presented with a sensation of foreign body in the throat, dysphonia, dyspnoea and dysphagia; we performed sonography (7.5 MHz linear probe), color Doppler (7 MHz Doppler frequeny, PRF 3500 Hz) and MRI (1.5 T, spin-echo T1- and T2-weighted images with administration of Gd-DTPA); a scan with 123 I demonstrated a relevant uptake at the base of the tongue, but no uptake at the typical thyroid location. The gland was removed and partially transplanted in the strap muscles of the neck. (orig.)

  5. Reevaluation of JPEG image compression to digitalized gastrointestinal endoscopic color images: a pilot study

    Science.gov (United States)

    Kim, Christopher Y.

    1999-05-01

    Endoscopic images p lay an important role in describing many gastrointestinal (GI) disorders. The field of radiology has been on the leading edge of creating, archiving and transmitting digital images. With the advent of digital videoendoscopy, endoscopists now have the ability to generate images for storage and transmission. X-rays can be compressed 30-40X without appreciable decline in quality. We reported results of a pilot study using JPEG compression of 24-bit color endoscopic images. For that study, the result indicated that adequate compression ratios vary according to the lesion and that images could be compressed to between 31- and 99-fold smaller than the original size without an appreciable decline in quality. The purpose of this study was to expand upon the methodology of the previous sty with an eye towards application for the WWW, a medium which would expand both clinical and educational purposes of color medical imags. The results indicate that endoscopists are able to tolerate very significant compression of endoscopic images without loss of clinical image quality. This finding suggests that even 1 MB color images can be compressed to well under 30KB, which is considered a maximal tolerable image size for downloading on the WWW.

  6. Transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions%经阴道彩色多普勒超声在子宫内膜病变诊断的应用价值

    Institute of Scientific and Technical Information of China (English)

    高鸣

    2015-01-01

    目的 探讨经阴道彩色多普勒超声在子宫内膜病变诊断中的应用价值,总结其应用经验.方法 对90例不规则阴道流血患者行经阴道彩色多普勒超声检查,分析其超声影像学资料,并将超声检查结果与诊刮以及患者术后病理诊断结果相对照.结果 本研究90例患者经阴道彩色多普勒超声检查确诊86例,其中子宫内膜增生36例、子宫内膜息肉42例,子宫内膜癌8例,确诊率为95.64%;漏诊4例,漏诊率为4.36%,其中1例子宫内膜癌病变,3例子宫内膜增生病变.结论 经阴道彩色多普勒超声检查子宫内膜病变操作简便、准确性高,超声检查时应注意测量子宫内膜厚度,观察内膜形态、内膜与肌层的关系、内膜回声特点以及子宫内膜内血流情况及阻力指数,作为诊断子宫内膜病变的重要检查方法,还需要结合患者的临床表现及其他影像学检查手段,以提高其确诊率.%Objective To investigate the application value of transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions,and summarize the application experience.Methods Ninety patients with irregular vaginal bleeding underwent transvaginal color Doppler ultrasound examination,the ultrasound image data were analyzed,and the ultrasonic inspection results and curettage and postoperative pathological diagnosis results were compared.Results Among the 90 cases,86 cases were diagnosed by transvaginal color Doppler ultrasound,of which 36 cases of endometrial hyperplasia,42 cases of endometrial polyps,endometrial carcinoma in 8 cases,the diagnosis rate was 95.64% ; 4 cases of missed diagnosis,the missed diagnosis rate was 4.36%,in which l case of endometrial carcinoma lesions,3 cases of uterus hyperplasia lesions.Conclusions Transvaginal color Doppler ultrasonography for endometrial lesions has simple operation,high accuracy,we should pay attention to measure the thickness of endometrium,endometrial morphology

  7. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  8. SCANDI – an all-sky Doppler imager for studies of thermospheric spatial structure

    Directory of Open Access Journals (Sweden)

    A. L. Aruliah

    2010-02-01

    Full Text Available A new all-sky Fabry-Perot Interferometer called the Scanning Doppler Imager (SCANDI was built and installed at Longyearbyen in December 2006. Observations have been made of the Doppler shifts and Doppler broadening of the 630 nm airglow and aurora, from which upper thermospheric winds and temperatures are calculated. SCANDI allows measurements over a field-of-view (FOV with a horizontal radius of nearly 600 km for observations at an altitude of 250 km using a time resolution of 8 min. The instrument provides the ability to observe thermospheric spatial structure within a FOV which overlaps that of the EISCAT Svalbard radar and CUTLASS SuperDARN radars. Coordinating with these instruments provides an important opportunity for studying ion-neutral coupling. The all-sky image is divided into several sectors to provide a horizontal spatial resolution of between 100–300 km. This is a powerful extension in observational capability but requires careful calibration and data analysis, as described here. Two observation modes were used: a fixed and a scanning etalon gap. SCANDI results are corroborated using the Longyearbyen single look direction FPI, and ESR measurements of the ion temperatures. The data show thermospheric temperature gradients of a few Kelvins per kilometre, and a great deal of meso-scale variability on spatial scales of several tens of kilometres.

  9. Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

    Science.gov (United States)

    Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A

    2006-01-01

    To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85

  10. Variational Histogram Equalization for Single Color Image Defogging

    Directory of Open Access Journals (Sweden)

    Li Zhou

    2016-01-01

    Full Text Available Foggy images taken in the bad weather inevitably suffer from contrast loss and color distortion. Existing defogging methods merely resort to digging out an accurate scene transmission in ignorance of their unpleasing distortion and high complexity. Different from previous works, we propose a simple but powerful method based on histogram equalization and the physical degradation model. By revising two constraints in a variational histogram equalization framework, the intensity component of a fog-free image can be estimated in HSI color space, since the airlight is inferred through a color attenuation prior in advance. To cut down the time consumption, a general variation filter is proposed to obtain a numerical solution from the revised framework. After getting the estimated intensity component, it is easy to infer the saturation component from the physical degradation model in saturation channel. Accordingly, the fog-free image can be restored with the estimated intensity and saturation components. In the end, the proposed method is tested on several foggy images and assessed by two no-reference indexes. Experimental results reveal that our method is relatively superior to three groups of relevant and state-of-the-art defogging methods.

  11. Airborne Doppler Wind Lidar Post Data Processing Software DAPS-LV

    Science.gov (United States)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable post processing of airborne Doppler wind LIDAR data. In an embodiment, airborne Doppler wind LIDAR data software written in LabVIEW may be provided and may run two versions of different airborne wind profiling algorithms. A first algorithm may be the Airborne Wind Profiling Algorithm for Doppler Wind LIDAR ("APOLO") using airborne wind LIDAR data from two orthogonal directions to estimate wind parameters, and a second algorithm may be a five direction based method using pseudo inverse functions to estimate wind parameters. The various embodiments may enable wind profiles to be compared using different algorithms, may enable wind profile data for long haul color displays to be generated, may display long haul color displays, and/or may enable archiving of data at user-selectable altitudes over a long observation period for data distribution and population.

  12. [Postpartal ovarian thrombophlebitis. Value of Doppler ultrasonograph y].

    Science.gov (United States)

    Renaud-Giono, A; Giraud, J R; Poulain, P; Proudhon, J F; Grall, J Y; Moquet, P Y; Darnault, J P

    1996-01-01

    Thrombophlebitis of the ovarian vein is a well recognized but uncommon complication during the postpartum period. We report a small series and emphasize the contribution of color Doppler and the basic therapeutic measures.

  13. An instructional guide for leaf color analysis using digital imaging software

    Science.gov (United States)

    Paula F. Murakami; Michelle R. Turner; Abby K. van den Berg; Paul G. Schaberg

    2005-01-01

    Digital color analysis has become an increasingly popular and cost-effective method utilized by resource managers and scientists for evaluating foliar nutrition and health in response to environmental stresses. We developed and tested a new method of digital image analysis that uses Scion Image or NIH image public domain software to quantify leaf color. This...

  14. Color image digitization and analysis for drum inspection

    International Nuclear Information System (INIS)

    Muller, R.C.; Armstrong, G.A.; Burks, B.L.; Kress, R.L.; Heckendorn, F.M.; Ward, C.R.

    1993-01-01

    A rust inspection system that uses color analysis to find rust spots on drums has been developed. The system is composed of high-resolution color video equipment that permits the inspection of rust spots on the order of 0.25 cm (0.1-in.) in diameter. Because of the modular nature of the system design, the use of open systems software (X11, etc.), the inspection system can be easily integrated into other environmental restoration and waste management programs. The inspection system represents an excellent platform for the integration of other color inspection and color image processing algorithms

  15. A fuzzy art neural network based color image processing and ...

    African Journals Online (AJOL)

    To improve the learning process from the input data, a new learning rule was suggested. In this paper, a new method is proposed to deal with the RGB color image pixels, which enables a Fuzzy ART neural network to process the RGB color images. The application of the algorithm was implemented and tested on a set of ...

  16. Advanced microlens and color filter process technology for the high-efficiency CMOS and CCD image sensors

    Science.gov (United States)

    Fan, Yang-Tung; Peng, Chiou-Shian; Chu, Cheng-Yu

    2000-12-01

    New markets are emerging for digital electronic image device, especially in visual communications, PC camera, mobile/cell phone, security system, toys, vehicle image system and computer peripherals for document capture. To enable one-chip image system that image sensor is with a full digital interface, can make image capture devices in our daily lives. Adding a color filter to such image sensor in a pattern of mosaics pixel or wide stripes can make image more real and colorful. We can say 'color filter makes the life more colorful color filter is? Color filter means can filter image light source except the color with specific wavelength and transmittance that is same as color filter itself. Color filter process is coating and patterning green, red and blue (or cyan, magenta and yellow) mosaic resists onto matched pixel in image sensing array pixels. According to the signal caught from each pixel, we can figure out the environment image picture. Widely use of digital electronic camera and multimedia applications today makes the feature of color filter becoming bright. Although it has challenge but it is very worthy to develop the process of color filter. We provide the best service on shorter cycle time, excellent color quality, high and stable yield. The key issues of advanced color process have to be solved and implemented are planarization and micro-lens technology. Lost of key points of color filter process technology have to consider will also be described in this paper.

  17. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    International Nuclear Information System (INIS)

    Ozturk, Adil; Ozturk, Ebru; Zeyrek, Fadile; Onur, Kahraman; Sirmatel, Ocal; Kat, Nurcan

    2005-01-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  18. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Adil [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)]. E-mail: ozturka26@hotmail.com; Ozturk, Ebru [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Zeyrek, Fadile [Department of Microbiology, Harran University School of Medicine, Sanliurfa (Turkey); Onur, Kahraman [Department of Urology, SSK Sanliurfa Hastanesi, Sanliurfa (Turkey); Sirmatel, Ocal [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Kat, Nurcan [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)

    2005-11-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  19. Fusion of lens-free microscopy and mobile-phone microscopy images for high-color-accuracy and high-resolution pathology imaging

    Science.gov (United States)

    Zhang, Yibo; Wu, Yichen; Zhang, Yun; Ozcan, Aydogan

    2017-03-01

    Digital pathology and telepathology require imaging tools with high-throughput, high-resolution and accurate color reproduction. Lens-free on-chip microscopy based on digital in-line holography is a promising technique towards these needs, as it offers a wide field of view (FOV >20 mm2) and high resolution with a compact, low-cost and portable setup. Color imaging has been previously demonstrated by combining reconstructed images at three discrete wavelengths in the red, green and blue parts of the visible spectrum, i.e., the RGB combination method. However, this RGB combination method is subject to color distortions. To improve the color performance of lens-free microscopy for pathology imaging, here we present a wavelet-based color fusion imaging framework, termed "digital color fusion microscopy" (DCFM), which digitally fuses together a grayscale lens-free microscope image taken at a single wavelength and a low-resolution and low-magnification color-calibrated image taken by a lens-based microscope, which can simply be a mobile phone based cost-effective microscope. We show that the imaging results of an H&E stained breast cancer tissue slide with the DCFM technique come very close to a color-calibrated microscope using a 40x objective lens with 0.75 NA. Quantitative comparison showed 2-fold reduction in the mean color distance using the DCFM method compared to the RGB combination method, while also preserving the high-resolution features of the lens-free microscope. Due to the cost-effective and field-portable nature of both lens-free and mobile-phone microscopy techniques, their combination through the DCFM framework could be useful for digital pathology and telepathology applications, in low-resource and point-of-care settings.

  20. Hyperspectral imaging using a color camera and its application for pathogen detection

    Science.gov (United States)

    Yoon, Seung-Chul; Shin, Tae-Sung; Heitschmidt, Gerald W.; Lawrence, Kurt C.; Park, Bosoon; Gamble, Gary

    2015-02-01

    This paper reports the results of a feasibility study for the development of a hyperspectral image recovery (reconstruction) technique using a RGB color camera and regression analysis in order to detect and classify colonies of foodborne pathogens. The target bacterial pathogens were the six representative non-O157 Shiga-toxin producing Escherichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) grown in Petri dishes of Rainbow agar. The purpose of the feasibility study was to evaluate whether a DSLR camera (Nikon D700) could be used to predict hyperspectral images in the wavelength range from 400 to 1,000 nm and even to predict the types of pathogens using a hyperspectral STEC classification algorithm that was previously developed. Unlike many other studies using color charts with known and noise-free spectra for training reconstruction models, this work used hyperspectral and color images, separately measured by a hyperspectral imaging spectrometer and the DSLR color camera. The color images were calibrated (i.e. normalized) to relative reflectance, subsampled and spatially registered to match with counterpart pixels in hyperspectral images that were also calibrated to relative reflectance. Polynomial multivariate least-squares regression (PMLR) was previously developed with simulated color images. In this study, partial least squares regression (PLSR) was also evaluated as a spectral recovery technique to minimize multicollinearity and overfitting. The two spectral recovery models (PMLR and PLSR) and their parameters were evaluated by cross-validation. The QR decomposition was used to find a numerically more stable solution of the regression equation. The preliminary results showed that PLSR was more effective especially with higher order polynomial regressions than PMLR. The best classification accuracy measured with an independent test set was about 90%. The results suggest the potential of cost-effective color imaging using hyperspectral image

  1. Perceptual distortion analysis of color image VQ-based coding

    Science.gov (United States)

    Charrier, Christophe; Knoblauch, Kenneth; Cherifi, Hocine

    1997-04-01

    It is generally accepted that a RGB color image can be easily encoded by using a gray-scale compression technique on each of the three color planes. Such an approach, however, fails to take into account correlations existing between color planes and perceptual factors. We evaluated several linear and non-linear color spaces, some introduced by the CIE, compressed with the vector quantization technique for minimum perceptual distortion. To study these distortions, we measured contrast and luminance of the video framebuffer, to precisely control color. We then obtained psychophysical judgements to measure how well these methods work to minimize perceptual distortion in a variety of color space.

  2. Automatic color preference correction for color reproduction

    Science.gov (United States)

    Tsukada, Masato; Funayama, Chisato; Tajima, Johji

    2000-12-01

    The reproduction of natural objects in color images has attracted a great deal of attention. Reproduction more pleasing colors of natural objects is one of the methods available to improve image quality. We developed an automatic color correction method to maintain preferred color reproduction for three significant categories: facial skin color, green grass and blue sky. In this method, a representative color in an object area to be corrected is automatically extracted from an input image, and a set of color correction parameters is selected depending on the representative color. The improvement in image quality for reproductions of natural image was more than 93 percent in subjective experiments. These results show the usefulness of our automatic color correction method for the reproduction of preferred colors.

  3. Spatial characterization of nanotextured surfaces by visual color imaging

    DEFF Research Database (Denmark)

    Feidenhans'l, Nikolaj Agentoft; Murthy, Swathi; Madsen, Morten H.

    2016-01-01

    We present a method using an ordinary color camera to characterize nanostructures from the visual color of the structures. The method provides a macroscale overview image from which micrometer-sized regions can be analyzed independently, hereby revealing long-range spatial variations...

  4. Objective Color Classification of Ecstasy Tablets by Hyperspectral Imaging

    NARCIS (Netherlands)

    Edelman, Gerda; Lopatka, Martin; Aalders, Maurice

    2013-01-01

    The general procedure followed in the examination of ecstasy tablets for profiling purposes includes a color description, which depends highly on the observers' perception. This study aims to provide objective quantitative color information using visible hyperspectral imaging. Both self-manufactured

  5. Modeling the Process of Color Image Recognition Using ART2 Neural Network

    Directory of Open Access Journals (Sweden)

    Todor Petkov

    2015-09-01

    Full Text Available This paper thoroughly describes the use of unsupervised adaptive resonance theory ART2 neural network for the purposes of image color recognition of x-ray images and images taken by nuclear magnetic resonance. In order to train the network, the pixel values of RGB colors are regarded as learning vectors with three values, one for red, one for green and one for blue were used. At the end the trained network was tested by the values of pictures and determines the design, or how to visualize the converted picture. As a result we had the same pictures with colors according to the network. Here we use the generalized net to prepare a model that describes the process of the color image recognition.

  6. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  7. Restoration of color in a remote sensing image and its quality evaluation

    Science.gov (United States)

    Zhang, Zuxun; Li, Zhijiang; Zhang, Jianqing; Wang, Zhihe

    2003-09-01

    This paper is focused on the restoration of color remote sensing (including airborne photo). A complete approach is recommended. It propose that two main aspects should be concerned in restoring a remote sensing image, that are restoration of space information, restoration of photometric information. In this proposal, the restoration of space information can be performed by making the modulation transfer function (MTF) as degradation function, in which the MTF is obtained by measuring the edge curve of origin image. The restoration of photometric information can be performed by improved local maximum entropy algorithm. What's more, a valid approach in processing color remote sensing image is recommended. That is splits the color remote sensing image into three monochromatic images which corresponding three visible light bands and synthesizes the three images after being processed separately with psychological color vision restriction. Finally, three novel evaluation variables are obtained based on image restoration to evaluate the image restoration quality in space restoration quality and photometric restoration quality. An evaluation is provided at last.

  8. Learning effective color features for content based image retrieval in dermatology

    NARCIS (Netherlands)

    Bunte, Kerstin; Biehl, Michael; Jonkman, Marcel F.; Petkov, Nicolai

    We investigate the extraction of effective color features for a content-based image retrieval (CBIR) application in dermatology. Effectiveness is measured by the rate of correct retrieval of images from four color classes of skin lesions. We employ and compare two different methods to learn

  9. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  10. Just Noticeable Distortion Model and Its Application in Color Image Watermarking

    Science.gov (United States)

    Liu, Kuo-Cheng

    In this paper, a perceptually adaptive watermarking scheme for color images is proposed in order to achieve robustness and transparency. A new just noticeable distortion (JND) estimator for color images is first designed in the wavelet domain. The key issue of the JND model is to effectively integrate visual masking effects. The estimator is an extension to the perceptual model that is used in image coding for grayscale images. Except for the visual masking effects given coefficient by coefficient by taking into account the luminance content and the texture of grayscale images, the crossed masking effect given by the interaction between luminance and chrominance components and the effect given by the variance within the local region of the target coefficient are investigated such that the visibility threshold for the human visual system (HVS) can be evaluated. In a locally adaptive fashion based on the wavelet decomposition, the estimator applies to all subbands of luminance and chrominance components of color images and is used to measure the visibility of wavelet quantization errors. The subband JND profiles are then incorporated into the proposed color image watermarking scheme. Performance in terms of robustness and transparency of the watermarking scheme is obtained by means of the proposed approach to embed the maximum strength watermark while maintaining the perceptually lossless quality of the watermarked color image. Simulation results show that the proposed scheme with inserting watermarks into luminance and chrominance components is more robust than the existing scheme while retaining the watermark transparency.

  11. CMEIAS color segmentation: an improved computing technology to process color images for quantitative microbial ecology studies at single-cell resolution.

    Science.gov (United States)

    Gross, Colin A; Reddy, Chandan K; Dazzo, Frank B

    2010-02-01

    Quantitative microscopy and digital image analysis are underutilized in microbial ecology largely because of the laborious task to segment foreground object pixels from background, especially in complex color micrographs of environmental samples. In this paper, we describe an improved computing technology developed to alleviate this limitation. The system's uniqueness is its ability to edit digital images accurately when presented with the difficult yet commonplace challenge of removing background pixels whose three-dimensional color space overlaps the range that defines foreground objects. Image segmentation is accomplished by utilizing algorithms that address color and spatial relationships of user-selected foreground object pixels. Performance of the color segmentation algorithm evaluated on 26 complex micrographs at single pixel resolution had an overall pixel classification accuracy of 99+%. Several applications illustrate how this improved computing technology can successfully resolve numerous challenges of complex color segmentation in order to produce images from which quantitative information can be accurately extracted, thereby gain new perspectives on the in situ ecology of microorganisms. Examples include improvements in the quantitative analysis of (1) microbial abundance and phylotype diversity of single cells classified by their discriminating color within heterogeneous communities, (2) cell viability, (3) spatial relationships and intensity of bacterial gene expression involved in cellular communication between individual cells within rhizoplane biofilms, and (4) biofilm ecophysiology based on ribotype-differentiated radioactive substrate utilization. The stand-alone executable file plus user manual and tutorial images for this color segmentation computing application are freely available at http://cme.msu.edu/cmeias/ . This improved computing technology opens new opportunities of imaging applications where discriminating colors really matter most

  12. An Improved Filtering Method for Quantum Color Image in Frequency Domain

    Science.gov (United States)

    Li, Panchi; Xiao, Hong

    2018-01-01

    In this paper we investigate the use of quantum Fourier transform (QFT) in the field of image processing. We consider QFT-based color image filtering operations and their applications in image smoothing, sharpening, and selective filtering using quantum frequency domain filters. The underlying principle used for constructing the proposed quantum filters is to use the principle of the quantum Oracle to implement the filter function. Compared with the existing methods, our method is not only suitable for color images, but also can flexibly design the notch filters. We provide the quantum circuit that implements the filtering task and present the results of several simulation experiments on color images. The major advantages of the quantum frequency filtering lies in the exploitation of the efficient implementation of the quantum Fourier transform.

  13. Wandering spleen in children: a report of 3 cases and a brief literature review underlining the importance of diagnostic imaging.

    Science.gov (United States)

    Lombardi, Roberta; Menchini, Laura; Corneli, Teresa; Magistrelli, Andrea; Accinni, Antonella; Monti, Lidia; Tomà, Paolo

    2014-03-01

    Wandering spleen is a rare condition in children that is often caused by loss or weakening of the splenic ligaments. Its clinical presentation is variable; 64% of children with wandering spleen have splenic torsion as a complication. To provide up-to-date information on the diagnosis, clinical management and diagnostic imaging approaches for wandering spleen in infants and children and to underline the importance of color Doppler US and CT in providing important information for patient management. We report a series of three children with wandering spleen treated at our children's hospital over the last 6 years. All three underwent clinical evaluation, color Doppler US and CT and were surgically treated. We also reviewed 40 articles that included 55 patients younger than 18 years reported in the Medline database from 2002 to 2012. We correlated pathological data with imaging findings. Color Doppler US, the first imaging modality in investigating abdominal symptoms in children with suspected wandering spleen, yielded a diagnostic sensitivity of 54.9%, whereas CT achieved about 71.7%. Radiologic evaluation has a major role in confirming the diagnosis of a suspected wandering spleen and avoiding potentially life-threatening complications requiring immediate surgery.

  14. Wandering spleen in children: a report of 3 cases and a brief literature review underlining the importance of diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lombardi, Roberta; Menchini, Laura; Corneli, Teresa; Magistrelli, Andrea; Monti, Lidia; Toma, Paolo [Bambino Gesu Pediatric Hospital, Department of Radiology, Rome (Italy); Accinni, Antonella [Bambino Gesu Pediatric Hospital, Department of General and Thoracic Surgery, Rome (Italy)

    2014-03-15

    Wandering spleen is a rare condition in children that is often caused by loss or weakening of the splenic ligaments. Its clinical presentation is variable; 64% of children with wandering spleen have splenic torsion as a complication. To provide up-to-date information on the diagnosis, clinical management and diagnostic imaging approaches for wandering spleen in infants and children and to underline the importance of color Doppler US and CT in providing important information for patient management. We report a series of three children with wandering spleen treated at our children's hospital over the last 6 years. All three underwent clinical evaluation, color Doppler US and CT and were surgically treated. We also reviewed 40 articles that included 55 patients younger than 18 years reported in the Medline database from 2002 to 2012. We correlated pathological data with imaging findings. Color Doppler US, the first imaging modality in investigating abdominal symptoms in children with suspected wandering spleen, yielded a diagnostic sensitivity of 54.9%, whereas CT achieved about 71.7%. Radiologic evaluation has a major role in confirming the diagnosis of a suspected wandering spleen and avoiding potentially life-threatening complications requiring immediate surgery. (orig.)

  15. Wandering spleen in children: a report of 3 cases and a brief literature review underlining the importance of diagnostic imaging

    International Nuclear Information System (INIS)

    Lombardi, Roberta; Menchini, Laura; Corneli, Teresa; Magistrelli, Andrea; Monti, Lidia; Toma, Paolo; Accinni, Antonella

    2014-01-01

    Wandering spleen is a rare condition in children that is often caused by loss or weakening of the splenic ligaments. Its clinical presentation is variable; 64% of children with wandering spleen have splenic torsion as a complication. To provide up-to-date information on the diagnosis, clinical management and diagnostic imaging approaches for wandering spleen in infants and children and to underline the importance of color Doppler US and CT in providing important information for patient management. We report a series of three children with wandering spleen treated at our children's hospital over the last 6 years. All three underwent clinical evaluation, color Doppler US and CT and were surgically treated. We also reviewed 40 articles that included 55 patients younger than 18 years reported in the Medline database from 2002 to 2012. We correlated pathological data with imaging findings. Color Doppler US, the first imaging modality in investigating abdominal symptoms in children with suspected wandering spleen, yielded a diagnostic sensitivity of 54.9%, whereas CT achieved about 71.7%. Radiologic evaluation has a major role in confirming the diagnosis of a suspected wandering spleen and avoiding potentially life-threatening complications requiring immediate surgery. (orig.)

  16. Color model comparative analysis for breast cancer diagnosis using H and E stained images

    Science.gov (United States)

    Li, Xingyu; Plataniotis, Konstantinos N.

    2015-03-01

    Digital cancer diagnosis is a research realm where signal processing techniques are used to analyze and to classify color histopathology images. Different from grayscale image analysis of magnetic resonance imaging or X-ray, colors in histopathology images convey large amount of histological information and thus play significant role in cancer diagnosis. Though color information is widely used in histopathology works, as today, there is few study on color model selections for feature extraction in cancer diagnosis schemes. This paper addresses the problem of color space selection for digital cancer classification using H and E stained images, and investigates the effectiveness of various color models (RGB, HSV, CIE L*a*b*, and stain-dependent H and E decomposition model) in breast cancer diagnosis. Particularly, we build a diagnosis framework as a comparison benchmark and take specific concerns of medical decision systems into account in evaluation. The evaluation methodologies include feature discriminate power evaluation and final diagnosis performance comparison. Experimentation on a publicly accessible histopathology image set suggests that the H and E decomposition model outperforms other assessed color spaces. For reasons behind various performance of color spaces, our analysis via mutual information estimation demonstrates that color components in the H and E model are less dependent, and thus most feature discriminate power is collected in one channel instead of spreading out among channels in other color spaces.

  17. Joint depth map and color consistency estimation for stereo images with different illuminations and cameras.

    Science.gov (United States)

    Heo, Yong Seok; Lee, Kyoung Mu; Lee, Sang Uk

    2013-05-01

    Abstract—In this paper, we propose a method that infers both accurate depth maps and color-consistent stereo images for radiometrically varying stereo images. In general, stereo matching and performing color consistency between stereo images are a chicken-and-egg problem since it is not a trivial task to simultaneously achieve both goals. Hence, we have developed an iterative framework in which these two processes can boost each other. First, we transform the input color images to log-chromaticity color space, from which a linear relationship can be established during constructing a joint pdf of transformed left and right color images. From this joint pdf, we can estimate a linear function that relates the corresponding pixels in stereo images. Based on this linear property, we present a new stereo matching cost by combining Mutual Information (MI), SIFT descriptor, and segment-based plane-fitting to robustly find correspondence for stereo image pairs which undergo radiometric variations. Meanwhile, we devise a Stereo Color Histogram Equalization (SCHE) method to produce color-consistent stereo image pairs, which conversely boost the disparity map estimation. Experimental results show that our method produces both accurate depth maps and color-consistent stereo images, even for stereo images with severe radiometric differences.

  18. P1-14: Relationship between Colorfulness Adaptation and Spatial Frequency Components in Natural Image

    Directory of Open Access Journals (Sweden)

    Shun Sakaibara

    2012-10-01

    Full Text Available We previously found the effect of colorfulness-adaptation in natural images. It was observed to be stronger in natural images than unnatural images, suggesting the influence of naturalness on the adaptation. However, what characteristics of images and what levels of visual system were involved were not examined enough. This research investigates whether the effect of colorfulness-adaptation is associated with spatial frequency components in natural images. If adaptation was a mechanism in early cortical level, the effect would be strong for adaptation and test images sharing similar spatial frequency components. In the experiment, we examined how the colorfulness impression of a test image changed following adaptation images with different levels of saturation. We selected several types of natural image from a standard image database for test and adaptation images. We also processed them to make shuffled images with spatial frequency component differed from the originals and phase-scrambled images with the component similar to the originals, for both adaptation and test images. Observers evaluated whether a test image was colorful or faded. Results show that the colorfulness perception of the test images was influenced by the saturation of the adaptation images. The effect was the strongest for the combination of natural (original adaptation and natural test images regardless of image types. The effect for the combination of phase-scrambled images was weaker than those of original images and stronger than those of shuffled images. They suggest that not only the spatial frequency components of an image but also the recognition of images would contribute to colorfulness-adaptation.

  19. Color sensitivity of the multi-exposure HDR imaging process

    Science.gov (United States)

    Lenseigne, Boris; Jacobs, Valéry Ann; Withouck, Martijn; Hanselaer, Peter; Jonker, Pieter P.

    2013-04-01

    Multi-exposure high dynamic range(HDR) imaging builds HDR radiance maps by stitching together different views of a same scene with varying exposures. Practically, this process involves converting raw sensor data into low dynamic range (LDR) images, estimate the camera response curves, and use them in order to recover the irradiance for every pixel. During the export, applying white balance settings and image stitching, which both have an influence on the color balance in the final image. In this paper, we use a calibrated quasi-monochromatic light source, an integrating sphere, and a spectrograph in order to evaluate and compare the average spectral response of the image sensor. We finally draw some conclusion about the color consistency of HDR imaging and the additional steps necessary to use multi-exposure HDR imaging as a tool to measure the physical quantities such as radiance and luminance.

  20. A Linear Criterion to sort Color Components in Images

    Directory of Open Access Journals (Sweden)

    Leonardo Barriga Rodriguez

    2017-01-01

    Full Text Available The color and its representation play a basic role in Image Analysis process. Several methods can be beneficial whenever they have a correct representation of wave-length variations used to represent scenes with a camera. A wide variety of spaces and color representations is founded in specialized literature. Each one is useful in concrete circumstances and others may offer redundant color information (for instance, all RGB components are high correlated. This work deals with the task of identifying and sorting which component from several color representations offers the majority of information about the scene. This approach is based on analyzing linear dependences among each color component, by the implementation of a new sorting algorithm based on entropy. The proposal is tested in several outdoor/indoor scenes with different light conditions. Repeatability and stability are tested in order to guarantee its use in several image analysis applications. Finally, the results of this work have been used to enhance an external algorithm to compensate the camera random vibrations.

  1. Multi-clues image retrieval based on improved color invariants

    Science.gov (United States)

    Liu, Liu; Li, Jian-Xun

    2012-05-01

    At present, image retrieval has a great progress in indexing efficiency and memory usage, which mainly benefits from the utilization of the text retrieval technology, such as the bag-of-features (BOF) model and the inverted-file structure. Meanwhile, because the robust local feature invariants are selected to establish BOF, the retrieval precision of BOF is enhanced, especially when it is applied to a large-scale database. However, these local feature invariants mainly consider the geometric variance of the objects in the images, and thus the color information of the objects fails to be made use of. Because of the development of the information technology and Internet, the majority of our retrieval objects is color images. Therefore, retrieval performance can be further improved through proper utilization of the color information. We propose an improved method through analyzing the flaw of shadow-shading quasi-invariant. The response and performance of shadow-shading quasi-invariant for the object edge with the variance of lighting are enhanced. The color descriptors of the invariant regions are extracted and integrated into BOF based on the local feature. The robustness of the algorithm and the improvement of the performance are verified in the final experiments.

  2. Muscular pathology: echographic and NMR imaging aspects

    International Nuclear Information System (INIS)

    Pascal-Suisse, P.; Beaurain, P.; Mougniot, C.

    1995-01-01

    A comparison of echographic techniques and NMR imaging has been done for the diagnosis of muscular trauma and tumor pathologies. In traumatic pathology, the echographic analysis allows to determine the complete assessment of recent muscular injuries. NMR imaging can be used in granuloma or fibrous callosity appreciation and for the analysis of deep injury (muscles and muscles-tendon junctions) and of muscular aponeurosis. Echography must be used together with color coding Doppler technique in the diagnosis of tumor pathology and for the study of slow fluxes. The recently available energy Doppler technique seems to be powerful in the study of vascularization of small expansive formations, but their extension to adjacent bone or tissue can only be appreciated using NMR imaging. (J.S.)

  3. Nutcracker Syndrome Accompanying Pelvic Congestion Syndrome; Color Doppler Sonography and Multislice CT Findings: A Case Report

    International Nuclear Information System (INIS)

    Inal, Mikail; Karadeniz Bilgili, Mihrace Yasemin; Sahin, Safa

    2014-01-01

    Nutcracker syndrome (NCS) is a rare pathology, caused by compression of the left renal vein (LRV) between the abdominal aorta (AA) and the superior mesenteric artery (SMA), due to reduction of the angle between AA and SMA. This leads to LRV varices, left gonadal vein varices and therefore, the pelvic congestion syndrome. For this reason, coexistence of NCS and pelvic congestion syndrome has been described. It manifests by hematuria, proteinuria, and nonspecific pelvic pain secondary to pelvic congestion, dyspareunia and persistent genital arousal. We report a 27-year-old woman who experienced hematuria and left flank pain. The diagnosis of NCS accompanied by pelvic congestion syndrome was missed initially, but later on the diagnosis was made by color Doppler ultrasound, abdominal computed tomography (CT) and CT angiography that were later performed. She refused interventional and surgical treatments, and was lost to follow up

  4. Featured Image: Revealing Hidden Objects with Color

    Science.gov (United States)

    Kohler, Susanna

    2018-02-01

    Stunning color astronomical images can often be the motivation for astronomers to continue slogging through countless data files, calculations, and simulations as we seek to understand the mysteries of the universe. But sometimes the stunning images can, themselves, be the source of scientific discovery. This is the case with the below image of Lynds Dark Nebula 673, located in the Aquila constellation, that was captured with the Mayall 4-meter telescope at Kitt Peak National Observatory by a team of scientists led by Travis Rector (University of Alaska Anchorage). After creating the image with a novel color-composite imaging method that reveals faint H emission (visible in red in both images here), Rector and collaborators identified the presence of a dozen new Herbig-Haro objects small cloud patches that are caused when material is energetically flung out from newly born stars. The image adapted above shows three of the new objects, HH 118789, aligned with two previously known objects, HH 32 and 332 suggesting they are driven by the same source. For more beautiful images and insight into the authors discoveries, check out the article linked below!Full view of Lynds Dark Nebula 673. Click for the larger view this beautiful composite image deserves! [T.A. Rector (University of Alaska Anchorage) and H. Schweiker (WIYN and NOAO/AURA/NSF)]CitationT. A. Rector et al 2018 ApJ 852 13. doi:10.3847/1538-4357/aa9ce1

  5. Color and textural quality of packaged wild rocket measured by multispectral imaging

    DEFF Research Database (Denmark)

    Løkke, Mette Marie; Seefeldt, Helene Fast; Skov, Thomas

    2013-01-01

    Green color and texture are important attributes for the perception of freshness of wild rocket. Packaging of green leafy vegetables can postpone senescence and yellowing, but a drawback is the risk of anaerobic respiration leading to loss of tissue integrity and development of an olive-brown color....... The hypothesis underlying this paper is that color and textural quality of packaged wild rocket leaves can be predicted by multispectral imaging for faster evaluation of visual quality of leafy green vegetables in scientific experiments. Multispectral imaging was correlated to sensory evaluation of packaged wild...... rocket quality. CIELAB values derived from the multispectral images and from a spectrophotometer changed during storage, but the data were insufficient to describe variation in sensory perceived color and texture. CIELAB values from the multispectral images allowed for a more detailed determination...

  6. Natural-color and color-infrared image mosaics of the Colorado River corridor in Arizona derived from the May 2009 airborne image collection

    Science.gov (United States)

    Davis, Philip A.

    2013-01-01

    The Grand Canyon Monitoring and Research Center (GCMRC) of the U.S. Geological Survey (USGS) periodically collects airborne image data for the Colorado River corridor within Arizona (fig. 1) to allow scientists to study the impacts of Glen Canyon Dam water release on the corridor’s natural and cultural resources. These data are collected from just above Glen Canyon Dam (in Lake Powell) down to the entrance of Lake Mead, for a total distance of 450 kilometers (km) and within a 500-meter (m) swath centered on the river’s mainstem and its seven main tributaries (fig. 1). The most recent airborne data collection in 2009 acquired image data in four wavelength bands (blue, green, red, and near infrared) at a spatial resolution of 20 centimeters (cm). The image collection used the latest model of the Leica ADS40 airborne digital sensor (the SH52), which uses a single optic for all four bands and collects and stores band radiance in 12-bits. Davis (2012) reported on the performance of the SH52 sensor and on the processing steps required to produce the nearly flawless four-band image mosaic (sectioned into map tiles) for the river corridor. The final image mosaic has a total of only 3 km of surface defects in addition to some areas of cloud shadow because of persistent inclement weather during data collection. The 2009 four-band image mosaic is perhaps the best image dataset that exists for the entire Arizona part of the Colorado River. Some analyses of these image mosaics do not require the full 12-bit dynamic range or all four bands of the calibrated image database, in which atmospheric scattering (or haze) had not been removed from the four bands. To provide scientists and the general public with image products that are more useful for visual interpretation, the 12-bit image data were converted to 8-bit natural-color and color-infrared images, which also removed atmospheric scattering within each wavelength-band image. The conversion required an evaluation of the

  7. HDR imaging and color constancy: two sides of the same coin?

    Science.gov (United States)

    McCann, John J.

    2011-01-01

    At first, we think that High Dynamic Range (HDR) imaging is a technique for improved recordings of scene radiances. Many of us think that human color constancy is a variation of a camera's automatic white balance algorithm. However, on closer inspection, glare limits the range of light we can detect in cameras and on retinas. All scene regions below middle gray are influenced, more or less, by the glare from the bright scene segments. Instead of accurate radiance reproduction, HDR imaging works well because it preserves the details in the scene's spatial contrast. Similarly, on closer inspection, human color constancy depends on spatial comparisons that synthesize appearances from all the scene segments. Can spatial image processing play similar principle roles in both HDR imaging and color constancy?

  8. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo [Keimyung University School of Medicine, Taegu (Korea, Republic of); Kim, Jung Sik [Radiological Clinic, Taegu (Korea, Republic of)

    2002-06-15

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  9. Digital color image encoding and decoding using a novel chaotic random generator

    International Nuclear Information System (INIS)

    Nien, H.H.; Huang, C.K.; Changchien, S.K.; Shieh, H.W.; Chen, C.T.; Tuan, Y.Y.

    2007-01-01

    This paper proposes a novel chaotic system, in which variables are treated as encryption keys in order to achieve secure transmission of digital color images. Since the dynamic response of chaotic system is highly sensitive to the initial values of a system and to the variation of a parameter, and chaotic trajectory is so unpredictable, we use elements of variables as encryption keys and apply these to computer internet communication of digital color images. As a result, we obtain much higher communication security. We adopt one statistic method involving correlation coefficient γ and FIPS PUB 140-1 to test on the distribution of distinguished elements of variables for continuous-time chaotic system, and accordingly select optimal encryption keys to use in secure communication of digital color images. At the transmitter end, we conduct RGB level decomposition on digital color images, and encrypt them with chaotic keys, and finally transmit them through computer internet. The same encryption keys are used to decrypt and recover the original images at the receiver end. Even if the encrypted images are stolen in the public channel, an intruder is not able to decrypt and recover the original images because of the lack of adequate encryption keys. Empirical example shows that the chaotic system and encryption keys applied in the encryption, transmission, decryption, and recovery of digital color images can achieve higher communication security and best recovered images

  10. Color Image Quality Assessment Based on CIEDE2000

    Directory of Open Access Journals (Sweden)

    Yang Yang

    2012-01-01

    Full Text Available Combining the color difference formula of CIEDE2000 and the printing industry standard for visual verification, we present an objective color image quality assessment method correlated with subjective vision perception. An objective score conformed to subjective perception (OSCSP Q was proposed to directly reflect the subjective visual perception. In addition, we present a general method to calibrate correction factors of color difference formula under real experimental conditions. Our experiment results show that the present DE2000-based metric can be consistent with human visual system in general application environment.

  11. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study.

    Science.gov (United States)

    Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel

    2012-01-01

    To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  12. On Adapting the Tensor Voting Framework to Robust Color Image Denoising

    Science.gov (United States)

    Moreno, Rodrigo; Garcia, Miguel Angel; Puig, Domenec; Julià, Carme

    This paper presents an adaptation of the tensor voting framework for color image denoising, while preserving edges. Tensors are used in order to encode the CIELAB color channels, the uniformity and the edginess of image pixels. A specific voting process is proposed in order to propagate color from a pixel to its neighbors by considering the distance between pixels, the perceptual color difference (by using an optimized version of CIEDE2000), a uniformity measurement and the likelihood of the pixels being impulse noise. The original colors are corrected with those encoded by the tensors obtained after the voting process. Peak to noise ratios and visual inspection show that the proposed methodology has a better performance than state-of-the-art techniques.

  13. Giga-pixel lensfree holographic microscopy and tomography using color image sensors.

    Directory of Open Access Journals (Sweden)

    Serhan O Isikman

    Full Text Available We report Giga-pixel lensfree holographic microscopy and tomography using color sensor-arrays such as CMOS imagers that exhibit Bayer color filter patterns. Without physically removing these color filters coated on the sensor chip, we synthesize pixel super-resolved lensfree holograms, which are then reconstructed to achieve ~350 nm lateral resolution, corresponding to a numerical aperture of ~0.8, across a field-of-view of ~20.5 mm(2. This constitutes a digital image with ~0.7 Billion effective pixels in both amplitude and phase channels (i.e., ~1.4 Giga-pixels total. Furthermore, by changing the illumination angle (e.g., ± 50° and scanning a partially-coherent light source across two orthogonal axes, super-resolved images of the same specimen from different viewing angles are created, which are then digitally combined to synthesize tomographic images of the object. Using this dual-axis lensfree tomographic imager running on a color sensor-chip, we achieve a 3D spatial resolution of ~0.35 µm × 0.35 µm × ~2 µm, in x, y and z, respectively, creating an effective voxel size of ~0.03 µm(3 across a sample volume of ~5 mm(3, which is equivalent to >150 Billion voxels. We demonstrate the proof-of-concept of this lensfree optical tomographic microscopy platform on a color CMOS image sensor by creating tomograms of micro-particles as well as a wild-type C. elegans nematode.

  14. COMPARATIVE STUDY OF EDGE BASED LSB MATCHING STEGANOGRAPHY FOR COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    A.J. Umbarkar

    2016-02-01

    Full Text Available Steganography is a very pivotal technique mainly used for covert transfer of information over a covert communication channel. This paper proposes a significant comparative study of the spatial LSB domain technique that focuses on sharper edges of the color as well as gray scale images for the purpose of data hiding and hides secret message first in sharper edge regions and then in smooth regions of the image. Message embedding depends on content of the image and message size. The experimental results illustrate that, for low embedding rate the method hides the message in sharp edges of cover image to get better stego image visualization quality. For high embedding rate, smooth regions and edges of the cover image are used for the purpose of data hiding. In this steganography method, color image and textured kind of image preserves better visual quality of stego image. The novelty of the comparative study is that, it helps to analyze the efficiency and performance of the method as it gives better results because it directly works on color images instead of converting to gray scale image.

  15. Comparison of Color Model in Cotton Image Under Conditions of Natural Light

    Science.gov (United States)

    Zhang, J. H.; Kong, F. T.; Wu, J. Z.; Wang, S. W.; Liu, J. J.; Zhao, P.

    Although the color images contain a large amount of information reflecting the species characteristics, different color models also get different information. The selection of color models is the key to separating crops from background effectively and rapidly. Taking the cotton images collected under natural light as the object, we convert the color components of RGB color model, HSL color model and YIQ color model respectively. Then, we use subjective evaluation and objective evaluation methods, evaluating the 9 color components of conversion. It is concluded that the Q component of the soil, straw and plastic film region gray values remain the same without larger fluctuation when using subjective evaluation method. In the objective evaluation, we use the variance method, average gradient method, gray prediction objective evaluation error statistics method and information entropy method respectively to find the minimum numerical of Q color component suitable for background segmentation.

  16. a New Graduation Algorithm for Color Balance of Remote Sensing Image

    Science.gov (United States)

    Zhou, G.; Liu, X.; Yue, T.; Wang, Q.; Sha, H.; Huang, S.; Pan, Q.

    2018-05-01

    In order to expand the field of view to obtain more data and information when doing research on remote sensing image, workers always need to mosaicking images together. However, the image after mosaic always has the large color differences and produces the gap line. This paper based on the graduation algorithm of tarigonometric function proposed a new algorithm of Two Quarter-rounds Curves (TQC). The paper uses the Gaussian filter to solve the program about the image color noise and the gap line. The paper used one of Greenland compiled data acquired in 1963 from Declassified Intelligence Photography Project (DISP) by ARGON KH-5 satellite, and used the photography of North Gulf, China, by Landsat satellite to experiment. The experimental results show that the proposed method has improved the accuracy of the results in two parts: on the one hand, for the large color differences remote sensing image will become more balanced. On the other hands, the remote sensing image will achieve more smooth transition.

  17. The role of Doppler ultrasonography in the evaluation of the renal function

    International Nuclear Information System (INIS)

    Krasteva, R.; Kiperova, B.; Andreev, E.; Kostadinova, I.; Petrov, T.; Hadjidekov, V.; Simeonova, A.

    2008-01-01

    The purpose of the study was to evaluate Doppler ultrasonography in the detection of the renal function. Sixty six patients with unilateral kidney changes were enrolled in this prospective study. 16 had hypoplastic kidney, 24 had hypofunctioned kidney and 26 had afunctioned kidney. 15 healthy potential donors were controls. A dynamic renal scintigraphy was performed with 74-111 MBq 99mTc-MAG3. The Color, Pulsed and Power Doppler were performed. The Vp and δVp derived from the spectrum of the segmental arteries were measured during Pulsed Doppler examination. There are not any difference between kidneys of health and hypoplastic kidneys on color and Power Doppler. The hypofunctioning kidneys had reduced blood flow and afunctioning kidneys had markedly reduced blood flow. The Vp of donors (48.8±7.6) and Vp of hypoplastic kidneys (49.9±4.8) were significantly higher compared to Vp of hypofunctioning kidneys (31.6±10.0) and to Vp of afunctioning kidneys (26.6±9.1), (p 14.5 cm/s in 93%, and from hypofunctioning kidney by delta Vp>10.5 cm/s in 87%. The Doppler ultrasonography is very useful in the evaluation of renal function. The changes of the Doppler parameters accurately marked the loss of function which can not be detected by elevation of the creatinine level. (authors)

  18. SUPERVISED AUTOMATIC HISTOGRAM CLUSTERING AND WATERSHED SEGMENTATION. APPLICATION TO MICROSCOPIC MEDICAL COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    Olivier Lezoray

    2011-05-01

    Full Text Available In this paper, an approach to the segmentation of microscopic color images is addressed, and applied to medical images. The approach combines a clustering method and a region growing method. Each color plane is segmented independently relying on a watershed based clustering of the plane histogram. The marginal segmentation maps intersect in a label concordance map. The latter map is simplified based on the assumption that the color planes are correlated. This produces a simplified label concordance map containing labeled and unlabeled pixels. The formers are used as an image of seeds for a color watershed. This fast and robust segmentation scheme is applied to several types of medical images.

  19. Color image encryption using random transforms, phase retrieval, chaotic maps, and diffusion

    Science.gov (United States)

    Annaby, M. H.; Rushdi, M. A.; Nehary, E. A.

    2018-04-01

    The recent tremendous proliferation of color imaging applications has been accompanied by growing research in data encryption to secure color images against adversary attacks. While recent color image encryption techniques perform reasonably well, they still exhibit vulnerabilities and deficiencies in terms of statistical security measures due to image data redundancy and inherent weaknesses. This paper proposes two encryption algorithms that largely treat these deficiencies and boost the security strength through novel integration of the random fractional Fourier transforms, phase retrieval algorithms, as well as chaotic scrambling and diffusion. We show through detailed experiments and statistical analysis that the proposed enhancements significantly improve security measures and immunity to attacks.

  20. Color image analysis of contaminants and bacteria transport in porous media

    Science.gov (United States)

    Rashidi, Mehdi; Dehmeshki, Jamshid; Daemi, Mohammad F.; Cole, Larry; Dickenson, Eric

    1997-10-01

    Transport of contaminants and bacteria in aqueous heterogeneous saturated porous systems have been studied experimentally using a novel fluorescent microscopic imaging technique. The approach involves color visualization and quantification of bacterium and contaminant distributions within a transparent porous column. By introducing stained bacteria and an organic dye as a contaminant into the column and illuminating the porous regions with a planar sheet of laser beam, contaminant and bacterial transport processes through the porous medium can be observed and measured microscopically. A computer controlled color CCD camera is used to record the fluorescent images as a function of time. These images are recorded by a frame accurate high resolution VCR and are then analyzed using a color image analysis code written in our laboratories. The color images are digitized this way and simultaneous concentration and velocity distributions of both contaminant and bacterium are evaluated as a function of time and pore characteristics. The approach provides a unique dynamic probe to observe these transport processes microscopically. These results are extremely valuable in in-situ bioremediation problems since microscopic particle-contaminant- bacterium interactions are the key to understanding and optimization of these processes.

  1. Copyright Protection of Color Imaging Using Robust-Encoded Watermarking

    Directory of Open Access Journals (Sweden)

    M. Cedillo-Hernandez

    2015-04-01

    Full Text Available In this paper we present a robust-encoded watermarking method applied to color images for copyright protection, which presents robustness against several geometric and signal processing distortions. Trade-off between payload, robustness and imperceptibility is a very important aspect which has to be considered when a watermark algorithm is designed. In our proposed scheme, previously to be embedded into the image, the watermark signal is encoded using a convolutional encoder, which can perform forward error correction achieving better robustness performance. Then, the embedding process is carried out through the discrete cosine transform domain (DCT of an image using the image normalization technique to accomplish robustness against geometric and signal processing distortions. The embedded watermark coded bits are extracted and decoded using the Viterbi algorithm. In order to determine the presence or absence of the watermark into the image we compute the bit error rate (BER between the recovered and the original watermark data sequence. The quality of the watermarked image is measured using the well-known indices: Peak Signal to Noise Ratio (PSNR, Visual Information Fidelity (VIF and Structural Similarity Index (SSIM. The color difference between the watermarked and original images is obtained by using the Normalized Color Difference (NCD measure. The experimental results show that the proposed method provides good performance in terms of imperceptibility and robustness. The comparison among the proposed and previously reported methods based on different techniques is also provided.

  2. A kind of color image segmentation algorithm based on super-pixel and PCNN

    Science.gov (United States)

    Xu, GuangZhu; Wang, YaWen; Zhang, Liu; Zhao, JingJing; Fu, YunXia; Lei, BangJun

    2018-04-01

    Image segmentation is a very important step in the low-level visual computing. Although image segmentation has been studied for many years, there are still many problems. PCNN (Pulse Coupled Neural network) has biological background, when it is applied to image segmentation it can be viewed as a region-based method, but due to the dynamics properties of PCNN, many connectionless neurons will pulse at the same time, so it is necessary to identify different regions for further processing. The existing PCNN image segmentation algorithm based on region growing is used for grayscale image segmentation, cannot be directly used for color image segmentation. In addition, the super-pixel can better reserve the edges of images, and reduce the influences resulted from the individual difference between the pixels on image segmentation at the same time. Therefore, on the basis of the super-pixel, the original PCNN algorithm based on region growing is improved by this paper. First, the color super-pixel image was transformed into grayscale super-pixel image which was used to seek seeds among the neurons that hadn't been fired. And then it determined whether to stop growing by comparing the average of each color channel of all the pixels in the corresponding regions of the color super-pixel image. Experiment results show that the proposed algorithm for the color image segmentation is fast and effective, and has a certain effect and accuracy.

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  4. Principles of image processing in machine vision systems for the color analysis of minerals

    Science.gov (United States)

    Petukhova, Daria B.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.

    2014-09-01

    At the moment color sorting method is one of promising methods of mineral raw materials enrichment. This method is based on registration of color differences between images of analyzed objects. As is generally known the problem with delimitation of close color tints when sorting low-contrast minerals is one of the main disadvantages of color sorting method. It is can be related with wrong choice of a color model and incomplete image processing in machine vision system for realizing color sorting algorithm. Another problem is a necessity of image processing features reconfiguration when changing the type of analyzed minerals. This is due to the fact that optical properties of mineral samples vary from one mineral deposit to another. Therefore searching for values of image processing features is non-trivial task. And this task doesn't always have an acceptable solution. In addition there are no uniform guidelines for determining criteria of mineral samples separation. It is assumed that the process of image processing features reconfiguration had to be made by machine learning. But in practice it's carried out by adjusting the operating parameters which are satisfactory for one specific enrichment task. This approach usually leads to the fact that machine vision system unable to estimate rapidly the concentration rate of analyzed mineral ore by using color sorting method. This paper presents the results of research aimed at addressing mentioned shortcomings in image processing organization for machine vision systems which are used to color sorting of mineral samples. The principles of color analysis for low-contrast minerals by using machine vision systems are also studied. In addition, a special processing algorithm for color images of mineral samples is developed. Mentioned algorithm allows you to determine automatically the criteria of mineral samples separation based on an analysis of representative mineral samples. Experimental studies of the proposed algorithm

  5. Toward optimal color image quality of television display

    Science.gov (United States)

    MacDonald, Lindsay W.; Endrikhovski, Sergej N.; Bech, Soren; Jensen, Kaj

    1999-12-01

    A general framework and first experimental results are presented for the `OPTimal IMage Appearance' (OPTIMA) project, which aims to develop a computational model for achieving optimal color appearance of natural images on adaptive CRT television displays. To achieve this goal we considered the perceptual constraints determining quality of displayed images and how they could be quantified. The practical value of the notion of optimal image appearance was translated from the high level of the perceptual constraints into a method for setting the display's parameters at the physical level. In general, the whole framework of quality determination includes: (1) evaluation of perceived quality; (2) evaluation of the individual perceptual attributes; and (3) correlation between the physical measurements, psychometric parameters and the subjective responses. We performed a series of psychophysical experiments, with observers viewing a series of color images on a high-end consumer television display, to investigate the relationships between Overall Image Quality and four quality-related attributes: Brightness Rendering, Chromatic Rendering, Visibility of Details and Overall Naturalness. The results of the experiments presented in this paper suggest that these attributes are highly inter-correlated.

  6. Systolic and Diastolic Function by Tissue Doppler Imaging Predicts Mortality in Patients with Atrial Fibrillation

    DEFF Research Database (Denmark)

    Dons, Maria; BieringSørensen, Tor; Jensen, Jan Skov

    2015-01-01

    AIM: Tissue Doppler Imaging (TDI) detects early signs of left ventricular dysfunction. The prognostic potential of TDI in patients with atrial fibrillation (AF) has, however, not yet been clarified. This study evaluates the prognostic value of TDI in patients with atrial fibrillation. METHODS...

  7. Fuzzy Logic-Based Filter for Removing Additive and Impulsive Noise from Color Images

    Science.gov (United States)

    Zhu, Yuhong; Li, Hongyang; Jiang, Huageng

    2017-12-01

    This paper presents an efficient filter method based on fuzzy logics for adaptively removing additive and impulsive noise from color images. The proposed filter comprises two parts including noise detection and noise removal filtering. In the detection part, the fuzzy peer group concept is applied to determine what type of noise is added to each pixel of the corrupted image. In the filter part, the impulse noise is deducted by the vector median filter in the CIELAB color space and an optimal fuzzy filter is introduced to reduce the Gaussian noise, while they can work together to remove the mixed Gaussian-impulse noise from color images. Experimental results on several color images proves the efficacy of the proposed fuzzy filter.

  8. Experimental single-chip color HDTV image acquisition system with 8M-pixel CMOS image sensor

    Science.gov (United States)

    Shimamoto, Hiroshi; Yamashita, Takayuki; Funatsu, Ryohei; Mitani, Kohji; Nojiri, Yuji

    2006-02-01

    We have developed an experimental single-chip color HDTV image acquisition system using 8M-pixel CMOS image sensor. The sensor has 3840 × 2160 effective pixels and is progressively scanned at 60 frames per second. We describe the color filter array and interpolation method to improve image quality with a high-pixel-count single-chip sensor. We also describe an experimental image acquisition system we used to measured spatial frequency characteristics in the horizontal direction. The results indicate good prospects for achieving a high quality single chip HDTV camera that reduces pseudo signals and maintains high spatial frequency characteristics within the frequency band for HDTV.

  9. Preparing Colorful Astronomical Images II

    Science.gov (United States)

    Levay, Z. G.; Frattare, L. M.

    2002-12-01

    We present additional techniques for using mainstream graphics software (Adobe Photoshop and Illustrator) to produce composite color images and illustrations from astronomical data. These techniques have been used on numerous images from the Hubble Space Telescope to produce photographic, print and web-based products for news, education and public presentation as well as illustrations for technical publication. We expand on a previous paper to present more detail and additional techniques, taking advantage of new or improved features available in the latest software versions. While Photoshop is not intended for quantitative analysis of full dynamic range data (as are IRAF or IDL, for example), we have had much success applying Photoshop's numerous, versatile tools to work with scaled images, masks, text and graphics in multiple semi-transparent layers and channels.

  10. Color Segmentation Approach of Infrared Thermography Camera Image for Automatic Fault Diagnosis

    International Nuclear Information System (INIS)

    Djoko Hari Nugroho; Ari Satmoko; Budhi Cynthia Dewi

    2007-01-01

    Predictive maintenance based on fault diagnosis becomes very important in current days to assure the availability and reliability of a system. The main purpose of this research is to configure a computer software for automatic fault diagnosis based on image model acquired from infrared thermography camera using color segmentation approach. This technique detects hot spots in equipment of the plants. Image acquired from camera is first converted to RGB (Red, Green, Blue) image model and then converted to CMYK (Cyan, Magenta, Yellow, Key for Black) image model. Assume that the yellow color in the image represented the hot spot in the equipment, the CMYK image model is then diagnosed using color segmentation model to estimate the fault. The software is configured utilizing Borland Delphi 7.0 computer programming language. The performance is then tested for 10 input infrared thermography images. The experimental result shows that the software capable to detect the faulty automatically with performance value of 80 % from 10 sheets of image input. (author)

  11. Colorization-Based RGB-White Color Interpolation using Color Filter Array with Randomly Sampled Pattern.

    Science.gov (United States)

    Oh, Paul; Lee, Sukho; Kang, Moon Gi

    2017-06-28

    Recently, several RGB-White (RGBW) color filter arrays (CFAs) have been proposed, which have extra white (W) pixels in the filter array that are highly sensitive. Due to the high sensitivity, the W pixels have better SNR (Signal to Noise Ratio) characteristics than other color pixels in the filter array, especially, in low light conditions. However, most of the RGBW CFAs are designed so that the acquired RGBW pattern image can be converted into the conventional Bayer pattern image, which is then again converted into the final color image by using conventional demosaicing methods, i.e., color interpolation techniques. In this paper, we propose a new RGBW color filter array based on a totally different color interpolation technique, the colorization algorithm. The colorization algorithm was initially proposed for colorizing a gray image into a color image using a small number of color seeds. Here, we adopt this algorithm as a color interpolation technique, so that the RGBW color filter array can be designed with a very large number of W pixels to make the most of the highly sensitive characteristics of the W channel. The resulting RGBW color filter array has a pattern with a large proportion of W pixels, while the small-numbered RGB pixels are randomly distributed over the array. The colorization algorithm makes it possible to reconstruct the colors from such a small number of RGB values. Due to the large proportion of W pixels, the reconstructed color image has a high SNR value, especially higher than those of conventional CFAs in low light condition. Experimental results show that many important information which are not perceived in color images reconstructed with conventional CFAs are perceived in the images reconstructed with the proposed method.

  12. Structure of a swirl-stabilized spray flame by imaging, laser Doppler velocimetry, and phase Doppler anemometry

    Science.gov (United States)

    Edwards, C. F.; Rudoff, R. C.

    1991-01-01

    Data are presented which describe the mean structure of a steady, swirl-stabilized, kerosene spray flame in the near-injector region of a research furnace. The data presented include ensemble-averaged results of schlieren, luminosity, and extinction imaging, measurement of the gas phase velocity field by laser Doppler velocimetry, and characterization of the condensed phase velocity by phase Doppler anemometry. The results of these studies define six key regions in the flame: the dense spray region; the rich, two-phase, fuel jet; the main air jet; the internal product recirculation zone; the external product recirculation zone; and the gaseous diffusion flame zone. The first five of these regions form a conical mixing layer which prepares the air and fuel for combustion. The air and fuel jets comprise the central portion of this mixing layer and are bounded on either side by the hot product gases of the internal and external recirculation zones. Entrainment of these product gases into the air/fuel streams provides the energy required to evaporate the fuel spray and initiate combustion. Intermittency of the internal recirculation and spray jet flows accounts for unexpected behavior observed in the aerodynamics of the two phases. The data reported herein are part of the database being accumulated on this spray flame for the purpose of detailed comparison with numerical modeling.

  13. Quantum Color Image Encryption Algorithm Based on A Hyper-Chaotic System and Quantum Fourier Transform

    Science.gov (United States)

    Tan, Ru-Chao; Lei, Tong; Zhao, Qing-Min; Gong, Li-Hua; Zhou, Zhi-Hong

    2016-12-01

    To improve the slow processing speed of the classical image encryption algorithms and enhance the security of the private color images, a new quantum color image encryption algorithm based on a hyper-chaotic system is proposed, in which the sequences generated by the Chen's hyper-chaotic system are scrambled and diffused with three components of the original color image. Sequentially, the quantum Fourier transform is exploited to fulfill the encryption. Numerical simulations show that the presented quantum color image encryption algorithm possesses large key space to resist illegal attacks, sensitive dependence on initial keys, uniform distribution of gray values for the encrypted image and weak correlation between two adjacent pixels in the cipher-image.

  14. Imaging tristimulus colorimeter for the evaluation of color in printed textiles

    Science.gov (United States)

    Hunt, Martin A.; Goddard, James S., Jr.; Hylton, Kathy W.; Karnowski, Thomas P.; Richards, Roger K.; Simpson, Marc L.; Tobin, Kenneth W., Jr.; Treece, Dale A.

    1999-03-01

    The high-speed production of textiles with complicated printed patterns presents a difficult problem for a colorimetric measurement system. Accurate assessment of product quality requires a repeatable measurement using a standard color space, such as CIELAB, and the use of a perceptually based color difference formula, e.g. (Delta) ECMC color difference formula. Image based color sensors used for on-line measurement are not colorimetric by nature and require a non-linear transformation of the component colors based on the spectral properties of the incident illumination, imaging sensor, and the actual textile color. This research and development effort describes a benchtop, proof-of-principle system that implements a projection onto convex sets (POCS) algorithm for mapping component color measurements to standard tristimulus values and incorporates structural and color based segmentation for improved precision and accuracy. The POCS algorithm consists of determining the closed convex sets that describe the constraints on the reconstruction of the true tristimulus values based on the measured imperfect values. We show that using a simulated D65 standard illuminant, commercial filters and a CCD camera, accurate (under perceptibility limits) per-region based (Delta) ECMC values can be measured on real textile samples.

  15. Diagnosic evaluation study of color doppler ultrasonic examination in abdominal wall endometriosis%彩色多普勒高频超声对腹壁子宫内膜异位症的诊断价值研究

    Institute of Scientific and Technical Information of China (English)

    史淼; 亓恒涛; 王倩; 张东东; 章阳

    2014-01-01

    Objective To explore the color doppler ultrasound manifestation of abdominal wall endometriosis,and evaluate its clinical value. Methods The manifestation of two-dimensional high frequency ultrasonography and color doppler imaging of 36 patients withabdominal wall endometriosis,which proven by surgery and pathology,were retrospectively analyzed.Results Among the 36 patients with abdominal wall endometriosis,1 6 cases located in fat layer,20 cases in muscular layer,with diameter ranging from 1 .1 to 5 .2 cm.With two-dimensionalultrasonography,there was no capsule,but with irregular morphology,blurred margins,low echoes inside and some parts of irregular no-echo areas.The size and internal echo of the mass changed respectively according to the menstruation.Color doppler ultrasound showed scattered or striped flow signals in the lesion,whose artery displayed low-speed and high resistance frequency spectrum.The accuracy and misdiagnosis rate of ultrasonography were 83.3% and 1 6.7%, respectively.Conclusions The color doppler ultrasound may directlydisplay the size,morphology,condition of internal echo and blood inflow of the abdominal wall endometriosis lesion.Therefore,it is the first choice of imaging examination for the diagnosis of abdominal wall endometriosis.%目的:探讨腹壁子宫内膜异位症的彩色多普勒高频超声表现,评价其临床应用价值。方法回顾性分析2010年2月至2013年12月,山东省聊城市人民医院经手术病理证实的腹壁子宫内膜异位症患者36例的高频超声二维图像及彩色多普勒超声表现。结果36例腹壁子宫内膜异位症患者中,位于脂肪层内16例,位于肌层内20例,直径1.1~5.2 cm。二维超声表现:无包膜,形态不规则,边缘不光滑,内部为不均质低回声,随月经的不同时期肿块大小及回声呈相应改变。彩色多普勒超声显示病灶内部可见点状或条状血流信号,其动脉均为

  16. Color Texture Image Retrieval Based on Local Extrema Features and Riemannian Distance

    Directory of Open Access Journals (Sweden)

    Minh-Tan Pham

    2017-10-01

    Full Text Available A novel efficient method for content-based image retrieval (CBIR is developed in this paper using both texture and color features. Our motivation is to represent and characterize an input image by a set of local descriptors extracted from characteristic points (i.e., keypoints within the image. Then, dissimilarity measure between images is calculated based on the geometric distance between the topological feature spaces (i.e., manifolds formed by the sets of local descriptors generated from each image of the database. In this work, we propose to extract and use the local extrema pixels as our feature points. Then, the so-called local extrema-based descriptor (LED is generated for each keypoint by integrating all color, spatial as well as gradient information captured by its nearest local extrema. Hence, each image is encoded by an LED feature point cloud and Riemannian distances between these point clouds enable us to tackle CBIR. Experiments performed on several color texture databases including Vistex, STex, color Brodazt, USPtex and Outex TC-00013 using the proposed approach provide very efficient and competitive results compared to the state-of-the-art methods.

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements into an array of ...

  18. Consistency and standardization of color in medical imaging: a consensus report.

    Science.gov (United States)

    Badano, Aldo; Revie, Craig; Casertano, Andrew; Cheng, Wei-Chung; Green, Phil; Kimpe, Tom; Krupinski, Elizabeth; Sisson, Christye; Skrøvseth, Stein; Treanor, Darren; Boynton, Paul; Clunie, David; Flynn, Michael J; Heki, Tatsuo; Hewitt, Stephen; Homma, Hiroyuki; Masia, Andy; Matsui, Takashi; Nagy, Balázs; Nishibori, Masahiro; Penczek, John; Schopf, Thomas; Yagi, Yukako; Yokoi, Hideto

    2015-02-01

    This article summarizes the consensus reached at the Summit on Color in Medical Imaging held at the Food and Drug Administration (FDA) on May 8-9, 2013, co-sponsored by the FDA and ICC (International Color Consortium). The purpose of the meeting was to gather information on how color is currently handled by medical imaging systems to identify areas where there is a need for improvement, to define objective requirements, and to facilitate consensus development of best practices. Participants were asked to identify areas of concern and unmet needs. This summary documents the topics that were discussed at the meeting and recommendations that were made by the participants. Key areas identified where improvements in color would provide immediate tangible benefits were those of digital microscopy, telemedicine, medical photography (particularly ophthalmic and dental photography), and display calibration. Work in these and other related areas has been started within several professional groups, including the creation of the ICC Medical Imaging Working Group.

  19. A new Watermarking System based on Discrete Cosine Transform (DCT) in color biometric images.

    Science.gov (United States)

    Dogan, Sengul; Tuncer, Turker; Avci, Engin; Gulten, Arif

    2012-08-01

    This paper recommend a biometric color images hiding approach An Watermarking System based on Discrete Cosine Transform (DCT), which is used to protect the security and integrity of transmitted biometric color images. Watermarking is a very important hiding information (audio, video, color image, gray image) technique. It is commonly used on digital objects together with the developing technology in the last few years. One of the common methods used for hiding information on image files is DCT method which used in the frequency domain. In this study, DCT methods in order to embed watermark data into face images, without corrupting their features.

  20. Cardiac time intervals by tissue Doppler imaging M-mode echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor

    2016-01-01

    for myocardial myocytes to achieve an LV pressure equal to that of aorta increases, resulting in a prolongation of the isovolumic contraction time (IVCT). Furthermore, the ability of myocardial myocytes to maintain the LV pressure decreases, resulting in reduction in the ejection time (ET). As LV diastolic...... of whether the LV is suffering from impaired systolic or diastolic function. A novel method of evaluating the cardiac time intervals has recently evolved. Using tissue Doppler imaging (TDI) M-mode through the mitral valve (MV) to estimate the cardiac time intervals may be an improved method reflecting global...

  1. A pilot study of three dimensional color CT images of brain diseases to improve informed consent

    International Nuclear Information System (INIS)

    Tanizaki, Yoshio; Akiyama, Takenori; Hiraga, Kenji; Akaji, Kazunori

    2005-01-01

    We have described brain diseases to patients and their family using monochrome CT images. It is thought that patients have difficulties in giving their consent to our conventional explanation because their understanding of brain diseases is based on three dimensional and color images, however, standard CT images are two dimensional and gray scale images. We have been trying to use three dimensional color CT images to improve the typical patient's comprehension of brain diseases. We also try to simulate surgery using these images. Multi-slice CT accumulates precise isotropic voxel data within a half minute. These two dimensional and monochrome data are converted to three dimensional color CT images by 3D workstation. Three dimensional color CT images of each brain structures (e.g. scalp, skull, brain, ventricles and lesions) are created separately. Then, selected structures are fused together for different purposes. These images are able to rotate around any axis. Because the methods to generate three-dimensional color images have not established, we neurosurgeons must create these images. In particular, when an operation is required, the surgeon should create the images. In this paper, we demonstrate how three-dimensional color CT images can improve informed consent. (author)

  2. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok [Dongkang Hospital, Ulsan (Korea, Republic of); Lee, Yeong Hwan [Taegu Catholic Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-06-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm.

  3. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    International Nuclear Information System (INIS)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok; Lee, Yeong Hwan

    1996-01-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm

  4. 2D Doppler backscattering using synthetic aperture microwave imaging of MAST edge plasmas

    Science.gov (United States)

    Thomas, D. A.; Brunner, K. J.; Freethy, S. J.; Huang, B. K.; Shevchenko, V. F.; Vann, R. G. L.

    2016-02-01

    Doppler backscattering (DBS) is already established as a powerful diagnostic; its extension to 2D enables imaging of turbulence characteristics from an extended region of the cut-off surface. The Synthetic Aperture Microwave Imaging (SAMI) diagnostic has conducted proof-of-principle 2D DBS experiments of MAST edge plasma. SAMI actively probes the plasma edge using a wide (±40° vertical and horizontal) and tuneable (10-34.5 GHz) beam. The Doppler backscattered signal is digitised in vector form using an array of eight Vivaldi PCB antennas. This allows the receiving array to be focused in any direction within the field of view simultaneously to an angular range of 6-24° FWHM at 10-34.5 GHz. This capability is unique to SAMI and is a novel way of conducting DBS experiments. In this paper the feasibility of conducting 2D DBS experiments is explored. Initial observations of phenomena previously measured by conventional DBS experiments are presented; such as momentum injection from neutral beams and an abrupt change in power and turbulence velocity coinciding with the onset of H-mode. In addition, being able to carry out 2D DBS imaging allows a measurement of magnetic pitch angle to be made; preliminary results are presented. Capabilities gained through steering a beam using a phased array and the limitations of this technique are discussed.

  5. Colorization and automated segmentation of human T2 MR brain images for characterization of soft tissues.

    Directory of Open Access Journals (Sweden)

    Muhammad Attique

    Full Text Available Characterization of tissues like brain by using magnetic resonance (MR images and colorization of the gray scale image has been reported in the literature, along with the advantages and drawbacks. Here, we present two independent methods; (i a novel colorization method to underscore the variability in brain MR images, indicative of the underlying physical density of bio tissue, (ii a segmentation method (both hard and soft segmentation to characterize gray brain MR images. The segmented images are then transformed into color using the above-mentioned colorization method, yielding promising results for manual tracing. Our color transformation incorporates the voxel classification by matching the luminance of voxels of the source MR image and provided color image by measuring the distance between them. The segmentation method is based on single-phase clustering for 2D and 3D image segmentation with a new auto centroid selection method, which divides the image into three distinct regions (gray matter (GM, white matter (WM, and cerebrospinal fluid (CSF using prior anatomical knowledge. Results have been successfully validated on human T2-weighted (T2 brain MR images. The proposed method can be potentially applied to gray-scale images from other imaging modalities, in bringing out additional diagnostic tissue information contained in the colorized image processing approach as described.

  6. A robust color image watermarking algorithm against rotation attacks

    Science.gov (United States)

    Han, Shao-cheng; Yang, Jin-feng; Wang, Rui; Jia, Gui-min

    2018-01-01

    A robust digital watermarking algorithm is proposed based on quaternion wavelet transform (QWT) and discrete cosine transform (DCT) for copyright protection of color images. The luminance component Y of a host color image in YIQ space is decomposed by QWT, and then the coefficients of four low-frequency subbands are transformed by DCT. An original binary watermark scrambled by Arnold map and iterated sine chaotic system is embedded into the mid-frequency DCT coefficients of the subbands. In order to improve the performance of the proposed algorithm against rotation attacks, a rotation detection scheme is implemented before watermark extracting. The experimental results demonstrate that the proposed watermarking scheme shows strong robustness not only against common image processing attacks but also against arbitrary rotation attacks.

  7. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...

  8. Quantitative Evaluation of Surface Color of Tomato Fruits Cultivated in Remote Farm Using Digital Camera Images

    Science.gov (United States)

    Hashimoto, Atsushi; Suehara, Ken-Ichiro; Kameoka, Takaharu

    To measure the quantitative surface color information of agricultural products with the ambient information during cultivation, a color calibration method for digital camera images and a remote monitoring system of color imaging using the Web were developed. Single-lens reflex and web digital cameras were used for the image acquisitions. The tomato images through the post-ripening process were taken by the digital camera in both the standard image acquisition system and in the field conditions from the morning to evening. Several kinds of images were acquired with the standard RGB color chart set up just behind the tomato fruit on a black matte, and a color calibration was carried out. The influence of the sunlight could be experimentally eliminated, and the calibrated color information consistently agreed with the standard ones acquired in the system through the post-ripening process. Furthermore, the surface color change of the tomato on the tree in a greenhouse was remotely monitored during maturation using the digital cameras equipped with the Field Server. The acquired digital color images were sent from the Farm Station to the BIFE Laboratory of Mie University via VPN. The time behavior of the tomato surface color change during the maturing process could be measured using the color parameter calculated based on the obtained and calibrated color images along with the ambient atmospheric record. This study is a very important step in developing the surface color analysis for both the simple and rapid evaluation of the crop vigor in the field and to construct an ambient and networked remote monitoring system for food security, precision agriculture, and agricultural research.

  9. Color-coded MR imaging phase velocity mapping with the Pixar image processor

    International Nuclear Information System (INIS)

    Singleton, H.R.; Cranney, G.B.; Pohost, G.M.

    1989-01-01

    The authors have developed a graphic interaction technique in which a mouse and cursor are used to assign colors to phase-sensitive MR images of the heart. Two colors are used, one for flow in the positive direction, another for flow in the negative direction. A lookup table is generated interactively by manipulating lines representing ramps superimposed on an intensity histogram. Intensity is made to vary with flow magnitude in each color's direction. Coded series of the ascending and descending aorta, and of two- and four-chamber views of the heart, have been generated. In conjunction with movie display, flow dynamics, especially changes in direction, are readily apparent

  10. Color management systems: methods and technologies for increased image quality

    Science.gov (United States)

    Caretti, Maria

    1997-02-01

    All the steps in the imaging chain -- from handling the originals in the prepress to outputting them on any device - - have to be well calibrated and adjusted to each other, in order to reproduce color images in a desktop environment as accurate as possible according to the original. Today most of the steps in the prepress production are digital and therefore it is realistic to believe that the color reproduction can be well controlled. This is true thanks to the last years development of fast, cost effective scanners, digital sources and digital proofing devices not the least. It is likely to believe that well defined tools and methods to control this imaging flow will lead to large cost and time savings as well as increased overall image quality. Until now, there has been a lack of good, reliable, easy-to- use systems (e.g. hardware, software, documentation, training and support) in an extent that has made them accessible to the large group of users of graphic arts production systems. This paper provides an overview of the existing solutions to manage colors in a digital pre-press environment. Their benefits and limitations are discussed as well as how they affect the production workflow and organization. The difference between a color controlled environment and one that is not is explained.

  11. Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

    Science.gov (United States)

    Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H

    2006-12-01

    To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (pultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.

  12. MEMS-based handheld fourier domain Doppler optical coherence tomography for intraoperative microvascular anastomosis imaging.

    Directory of Open Access Journals (Sweden)

    Yong Huang

    Full Text Available To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis.A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager.With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral×512(axial pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images.A miniature handheld OCT imager that can be used for intraoperative evaluation of

  13. Perivesical varices and portal hypertension: imaging study; Varices perivesiculares e hipertension postal. Estudio por imagen

    Energy Technology Data Exchange (ETDEWEB)

    Mallorquin Jimenez, F; Medina Benitez, A; Lopez Machado, E; Pardo Moreno, M D; Garrido Moreno, C; Pastor Rull, J [Servicio de Radiodiagnostico, Hospital General de Especialidades Virgen de la Nieve, Granada (Spain)

    1995-07-01

    Nine patients with portal hypertension syndrome and Perivesical varices are studied retrospectively by means of imaging techniques including ultrasound, duplex Doppler, color Doppler, CT and angiography. All the patients presented portal thrombosis and thickening of the bladder wall. These collaterals either represent a shunting of hepato pedal flow or correspond to blood stasis associated with said syndrome. Ultrasound, whether involving duplex Doppler or color Doppler techniques, is highly useful to detect the presence of Perivesical varices which appear as tubular or rounded hypo echogenic areas in the bladder wall. Given the association of this entity with bladder wall thickening, it should be taken into account in any clinical situation involving said change, especially in patients with portal hypertension; moreover knowledge of its presence is of great importance when the possibility of creating shunts by means of interventional or surgical vascular procedures or other types of abdominal procedures are being considered because of the risk of bleeding. (Author)

  14. Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sørensen, Tor; Søgaard, Peter

    2016-01-01

    BACKGROUND: The current method for a non-invasive assessment of diastolic dysfunction is complex with the use of algorithms of many different echocardiographic parameters. Total average diastolic longitudinal displacement (LD), determined by colour tissue Doppler imaging (TDI) via the measurement...

  15. #TheDress: Categorical perception of an ambiguous color image.

    Science.gov (United States)

    Lafer-Sousa, Rosa; Conway, Bevil R

    2017-10-01

    We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region.

  16. #TheDress: Categorical perception of an ambiguous color image

    Science.gov (United States)

    Lafer-Sousa, Rosa; Conway, Bevil R.

    2017-01-01

    We present a full analysis of data from our preliminary report (Lafer-Sousa, Hermann, & Conway, 2015) and test whether #TheDress image is multistable. A multistable image must give rise to more than one mutually exclusive percept, typically within single individuals. Clustering algorithms of color-matching data showed that the dress was seen categorically, as white/gold (W/G) or blue/black (B/K), with a blue/brown transition state. Multinomial regression predicted categorical labels. Consistent with our prior hypothesis, W/G observers inferred a cool illuminant, whereas B/K observers inferred a warm illuminant; moreover, subjects could use skin color alone to infer the illuminant. The data provide some, albeit weak, support for our hypothesis that day larks see the dress as W/G and night owls see it as B/K. About half of observers who were previously familiar with the image reported switching categories at least once. Switching probability increased with professional art experience. Priming with an image that disambiguated the dress as B/K biased reports toward B/K (priming with W/G had negligible impact); furthermore, knowledge of the dress's true colors and any prior exposure to the image shifted the population toward B/K. These results show that some people have switched their perception of the dress. Finally, consistent with a role of attention and local image statistics in determining how multistable images are seen, we found that observers tended to discount as achromatic the dress component that they did not attend to: B/K reporters focused on a blue region, whereas W/G reporters focused on a golden region. PMID:29090319

  17. Color evaluation of computer-generated color rainbow holography

    International Nuclear Information System (INIS)

    Shi, Yile; Wang, Hui; Wu, Qiong

    2013-01-01

    A color evaluation approach for computer-generated color rainbow holography (CGCRH) is presented. Firstly, the relationship between color quantities of a computer display and a color computer-generated holography (CCGH) colorimetric system is discussed based on color matching theory. An isochromatic transfer relationship of color quantity and amplitude of object light field is proposed. Secondly, the color reproduction mechanism and factors leading to the color difference between the color object and the holographic image that is reconstructed by CGCRH are analyzed in detail. A quantitative color calculation method for the holographic image reconstructed by CGCRH is given. Finally, general color samples are selected as numerical calculation test targets and the color differences between holographic images and test targets are calculated based on our proposed method. (paper)

  18. Evaluation of portal hypertension in cirrhotic patients using color duplex-doppler ultrasound. Preliminary study; Evaluacion de la hipertension portal del cirrotico mediante ultrasonografia duplex-Doppler color. Estudio prliminar

    Energy Technology Data Exchange (ETDEWEB)

    Varas, M J; Torres, G; Sanllely, H [Unidad de Ecografias, Consorcio del Hospital de la Cruz Roja, L` Hospitalet de Llobregat, Barcelona (Spain)

    1996-09-01

    The objective was to compare data obtained by color duplex-Doppler ultrasound (mean velocity, flow and portal vein congestion index) in patients with chronic diffuse liver disease with and without portal hypertension (PH) (demonstrated endoscopically) with that of a healthy control group. Over a two-year period, 50 studies were performed in 10 healthy subjects (control group) with a mean age of 36 years and in 40 chronic liver disease patients (study group with a mean age of 58 years), most of whom presented alcoholic liver cirrhosis and belonged to Child-Pugh class B. They were subdivided according to endoscopic study into patients without (group 1) and with (group 2) portal hypertension. There were statistically significant differences in the diameters of splenic vein, spleen, portal vein and in the portal Vm, which decreased as the Child-Pugh score rose. When the patients without (group 1) and with (group 2) endoscopic evidence of PH (esophageal varices)were analyzed and compared, the two groups presented no statistically significant differences with respect to portal Vm, blood flow out of the liver, presence of collateral vessels, or the portal vein congestion index; the latter was significantly different in both the study group as a whole and in the patients with PH when compared with the control group. Given that this report is based on a pilot study which requires a larger sample number, we are unable to arrive at definitive conclusions. (Author) 18 refs.

  19. A Fast, Background-Independent Retrieval Strategy for Color Image Databases

    National Research Council Canada - National Science Library

    Das, M; Draper, B. A; Lim, W. J; Manmatha, R; Riseman, E. M

    1996-01-01

    We describe an interactive, multi-phase color-based image retrieval system which is capable of identifying query objects specified by the user in an image in the presence of significant, interfering backgrounds...

  20. Colored Chaos

    Science.gov (United States)

    2004-01-01

    [figure removed for brevity, see original site] Released 7 May 2004 This daytime visible color image was collected on May 30, 2002 during the Southern Fall season in Atlantis Chaos. The THEMIS VIS camera is capable of capturing color images of the martian surface using its five different color filters. In this mode of operation, the spatial resolution and coverage of the image must be reduced to accommodate the additional data volume produced from the use of multiple filters. To make a color image, three of the five filter images (each in grayscale) are selected. Each is contrast enhanced and then converted to a red, green, or blue intensity image. These three images are then combined to produce a full color, single image. Because the THEMIS color filters don't span the full range of colors seen by the human eye, a color THEMIS image does not represent true color. Also, because each single-filter image is contrast enhanced before inclusion in the three-color image, the apparent color variation of the scene is exaggerated. Nevertheless, the color variation that does appear is representative of some change in color, however subtle, in the actual scene. Note that the long edges of THEMIS color images typically contain color artifacts that do not represent surface variation. Image information: VIS instrument. Latitude -34.5, Longitude 183.6 East (176.4 West). 38 meter/pixel resolution. Note: this THEMIS visual image has not been radiometrically nor geometrically calibrated for this preliminary release. An empirical correction has been performed to remove instrumental effects. A linear shift has been applied in the cross-track and down-track direction to approximate spacecraft and planetary motion. Fully calibrated and geometrically projected images will be released through the Planetary Data System in accordance with Project policies at a later time. NASA's Jet Propulsion Laboratory manages the 2001 Mars Odyssey mission for NASA's Office of Space Science, Washington, D

  1. Use of image analysis to assess color response on plants caused by herbicide application

    DEFF Research Database (Denmark)

    Asif, Ali; Streibig, Jens Carl; Duus, Joachim

    2013-01-01

    by herbicides. The range of color components of green and nongreen parts of the plants and soil in Hue, Saturation, and Brightness (HSB) color space were used for segmentation. The canopy color changes of barley, winter wheat, red fescue, and brome fescue caused by doses of a glyphosate and diflufenican mixture...... for the green and nongreen parts of the plants and soil were different. The relative potencies were not significantly different from one, indicating that visual and image analysis estimations were about the same. The comparison results suggest that image analysis can be used to assess color changes of plants......In herbicide-selectivity experiments, response can be measured by visual inspection, stand counts, plant mortality, and biomass. Some response types are relative to nontreated control. We developed a nondestructive method by analyzing digital color images to quantify color changes in leaves caused...

  2. One-Shot Color Astronomical Imaging In Less Time, For Less Money!

    CERN Document Server

    Kennedy, L A

    2012-01-01

    Anyone who has seen recent pictures of the many wondrous objects in space has surely been amazed by the stunning color images. Trying to capture images like these through your own telescope has always seemed too time-consuming, expensive, and complicated. However, with improvements in affordable, easy-to-use CCD imaging technology, you can now capture amazing images yourself. With today's improved "one-shot" color imagers, high-quality images can be taken in a fraction of the time and at a fraction of the cost, right from your own backyard. This book will show you how to harness the power of today's computerized telescopes and entry-level imagers to capture spectacular images that you can share with family and friends. It covers such topics as - evaluating your existing equipment, choosing the right imager, finding targets to image, telescope alignment, focusing and framing the image, exposure times, aligning and stacking multiple frames, image calibration, and enhancement techniques! - how to expand the numb...

  3. Security of Color Image Data Designed by Public-Key Cryptosystem Associated with 2D-DWT

    Science.gov (United States)

    Mishra, D. C.; Sharma, R. K.; Kumar, Manish; Kumar, Kuldeep

    2014-08-01

    In present times the security of image data is a major issue. So, we have proposed a novel technique for security of color image data by public-key cryptosystem or asymmetric cryptosystem. In this technique, we have developed security of color image data using RSA (Rivest-Shamir-Adleman) cryptosystem with two-dimensional discrete wavelet transform (2D-DWT). Earlier proposed schemes for security of color images designed on the basis of keys, but this approach provides security of color images with the help of keys and correct arrangement of RSA parameters. If the attacker knows about exact keys, but has no information of exact arrangement of RSA parameters, then the original information cannot be recovered from the encrypted data. Computer simulation based on standard example is critically examining the behavior of the proposed technique. Security analysis and a detailed comparison between earlier developed schemes for security of color images and proposed technique are also mentioned for the robustness of the cryptosystem.

  4. Cryptanalysis and Improvement of the Robust and Blind Watermarking Scheme for Dual Color Image

    Directory of Open Access Journals (Sweden)

    Hai Nan

    2015-01-01

    Full Text Available With more color images being widely used on the Internet, the research on embedding color watermark image into color host image has been receiving more attention. Recently, Su et al. have proposed a robust and blind watermarking scheme for dual color image, in which the main innovation is the using of two-level DCT. However, it has been demonstrated in this paper that the original scheme in Su’s study is not secure and can be attacked by our proposed method. In addition, some errors in the original scheme have been pointed out. Also, an improvement measure is presented to enhance the security of the original watermarking scheme. The proposed method has been confirmed by both theoretical analysis and experimental results.

  5. Quantification of colour Doppler activity in the wrist in patients with rheumatoid arthritis - the reliability of different methods for image selection and evaluation

    DEFF Research Database (Denmark)

    Ellegaard, K.; Torp-Pedersen, S.; Lund, H.

    2008-01-01

    measurements in the wrist of patients with rheumatoid arthritis (RA) using different selection and quantification methods. Materials and Methods: 14 patients with RA had their wrist scanned twice by the same investigator with an interval of 30 Minutes, The images for analysis were selected either......Purpose: The amount Of colour Doppler activity in the inflamed synovium is used to quantity inflammatory activity. The measurements may vary due to image selection, quantification method, and point in cardiac cycle. This study investigated the test-retest reliability Of ultrasound colour Doppler...... was obtained when the images were selected guided by colour Doppler and the Subsequent quantification was (done in an area defined by anatomical Structures. With this method, the intra-class coefficient ICC (2.1) was 0.95 and the within-subject SD (SW) was 0.017, indicating good reliability. In contrast, poor...

  6. Sonographic evaluation of thyroiditis with color flow study.

    Science.gov (United States)

    Sultana, N; Rima, S; Rahman, S; Azad, S A; Karim, M E; Shawkat, S; Ahsan, M; Kamal, M M; Begum, M

    2014-01-01

    This cross sectional study was carried out in the Department of Radiology and Imaging, Bangabandhu Sheikh Mujib Medical University, Bangladesh in collaboration with the Department of Endocrinology and Department of Histopathology of the same hospital during the period of March 2007 to February 2008 to determine efficacy of ultrasonogram in the evaluation of thyroiditis and to compare its results with color flow Doppler study. For this purpose, a total of 50 patients having clinical suspicion of thyroiditis were enrolled in this study. Ultrasound and color Doppler were done in all these patients. Then all patients underwent for FNAC in the Histopathology department. Correlation between sonographic diagnosis and histopathological diagnosis were observed. Out of these 50 patients 10(20%) were male and 40 (80%) were female with age ranging from 12 to 50 years, highest between 21 to 30 years. The mean age of the patients was 30.42±9.57 years. On unltrasonographic findings of thyroid gland 42.0% patients had regular and 58.0% had irregular margin. Seventy percent had fibrosis, 14.0% had feature of necrosis, 48.0% had lymphadenopathy. Out of all patients 6.0% had normal echogenic feature, 16.0% had increased and 78.0% decreased echogeneic feature. Twelve percent (12.0%) patients had homogeneous and 88.0% had heterogeneous pattern of echogenecity. Thirty eight percent (38%) patients had focal nodules. Sixty percent (60.0%) patients had focal swelling and 40.0% had diffuse swelling. On color flow Doppler 28.0% had normal, 38.0% had increased and 34.0% decreased vascular flow pattern. USG reports revealed that 48.0% had thyromegaly, 36.0% had thyroid nodule, 10.0% had multinodular goiter and 6.0% had thyroid abscess. FNAC diagnosis revealed that 34.0% patients had Hashimoto's thyroiditis, 24.0% had lymphocytic thyroiditis, 18.0% had granulomatous thyroiditis, 6.0% had abscess, 8.0% had goitre and 10.0% nonspecific. USG and CFD are recommended modalities for the diagnosis of

  7. Modeling a color-rendering operator for high dynamic range images using a cone-response function

    Science.gov (United States)

    Choi, Ho-Hyoung; Kim, Gi-Seok; Yun, Byoung-Ju

    2015-09-01

    Tone-mapping operators are the typical algorithms designed to produce visibility and the overall impression of brightness, contrast, and color of high dynamic range (HDR) images on low dynamic range (LDR) display devices. Although several new tone-mapping operators have been proposed in recent years, the results of these operators have not matched those of the psychophysical experiments based on the human visual system. A color-rendering model that is a combination of tone-mapping and cone-response functions using an XYZ tristimulus color space is presented. In the proposed method, the tone-mapping operator produces visibility and the overall impression of brightness, contrast, and color in HDR images when mapped onto relatively LDR devices. The tone-mapping resultant image is obtained using chromatic and achromatic colors to avoid well-known color distortions shown in the conventional methods. The resulting image is then processed with a cone-response function wherein emphasis is placed on human visual perception (HVP). The proposed method covers the mismatch between the actual scene and the rendered image based on HVP. The experimental results show that the proposed method yields an improved color-rendering performance compared to conventional methods.

  8. Wide angle Michelson Doppler imaging interferometer. [measuring atmospheric emissions

    Science.gov (United States)

    Shepherd, G. G.

    1980-01-01

    The optical system, stepping control, phase and modulation depth, array detector, and directions sensor are described for a specialized type of Michelson interferometer which works at sufficiently high resolution to measure the line widths and Doppler shifts of naturally occurring atmospheric emissions. With its imaging capability, the instrument can potentially supply this data independently for each element of the 100 x 100 detector array. The experiment seeks: (1) to obtain vertical profiles of atmospheric winds and temperatures as functions of latitude by observing near the limb; (2) to acquire exploratory wind and temperature data on smaller scale structures in airglow irregularities and in auroral forms; and (3) to collaborate with other Spacelab experiments, such as barium cloud releases, in providing wind and temperature data.

  9. Complex regression Doppler optical coherence tomography

    Science.gov (United States)

    Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2018-04-01

    We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.

  10. Generating color terrain images in an emergency response system

    International Nuclear Information System (INIS)

    Belles, R.D.

    1985-08-01

    The Atmospheric Release Advisory Capability (ARAC) provides real-time assessments of the consequences resulting from an atmospheric release of radioactive material. In support of this operation, a system has been created which integrates numerical models, data acquisition systems, data analysis techniques, and professional staff. Of particular importance is the rapid generation of graphical images of the terrain surface in the vicinity of the accident site. A terrain data base and an associated acquisition system have been developed that provide the required terrain data. This data is then used as input to a collection of graphics programs which create and display realistic color images of the terrain. The graphics system currently has the capability of generating color shaded relief images from both overhead and perspective viewpoints within minutes. These images serve to quickly familiarize ARAC assessors with the terrain near the release location, and thus permit them to make better informed decisions in modeling the behavior of the released material. 7 refs., 8 figs

  11. Neurilemmoma of the glans penis: ultrasonography and magnetic resonance imaging findings.

    Science.gov (United States)

    Jung, Dae Chul; Hwang, Sung Il; Jung, Sung Il; Kim, Sun Ho; Kim, Seung Hyup

    2006-01-01

    Neurilemmoma of the glans penis is rare, and no imaging findings have been reported. A case of neurilemmoma of the glans penis is presented. Ultrasonography (US) and magnetic resonance imaging revealed a well-defined small mass in the glans penis. The mass appeared hypoechoic on gray-scale US and hypervascular on color Doppler US. Magnetic resonance imaging revealed high signal intensity of the mass on a T2-weighted image and strong enhancement on a contrast-enhanced T1-weighted image.

  12. Visibility enhancement of color images using Type-II fuzzy membership function

    Science.gov (United States)

    Singh, Harmandeep; Khehra, Baljit Singh

    2018-04-01

    Images taken in poor environmental conditions decrease the visibility and hidden information of digital images. Therefore, image enhancement techniques are necessary for improving the significant details of these images. An extensive review has shown that histogram-based enhancement techniques greatly suffer from over/under enhancement issues. Fuzzy-based enhancement techniques suffer from over/under saturated pixels problems. In this paper, a novel Type-II fuzzy-based image enhancement technique has been proposed for improving the visibility of images. The Type-II fuzzy logic can automatically extract the local atmospheric light and roughly eliminate the atmospheric veil in local detail enhancement. The proposed technique has been evaluated on 10 well-known weather degraded color images and is also compared with four well-known existing image enhancement techniques. The experimental results reveal that the proposed technique outperforms others regarding visible edge ratio, color gradients and number of saturated pixels.

  13. Luminance contours can gate afterimage colors and "real" colors.

    Science.gov (United States)

    Anstis, Stuart; Vergeer, Mark; Van Lier, Rob

    2012-09-06

    It has long been known that colored images may elicit afterimages in complementary colors. We have already shown (Van Lier, Vergeer, & Anstis, 2009) that one and the same adapting image may result in different afterimage colors, depending on the test contours presented after the colored image. The color of the afterimage depends on two adapting colors, those both inside and outside the test. Here, we further explore this phenomenon and show that the color-contour interactions shown for afterimage colors also occur for "real" colors. We argue that similar mechanisms apply for both types of stimulation.

  14. Modeling human color categorization: Color discrimination and color memory

    NARCIS (Netherlands)

    Heskes, T.; van den Broek, Egon; Lucas, P.; Hendriks, Maria A.; Vuurpijl, L.G.; Puts, M.J.H.; Wiegerinck, W.

    2003-01-01

    Color matching in Content-Based Image Retrieval is done using a color space and measuring distances between colors. Such an approach yields non-intuitive results for the user. We introduce color categories (or focal colors), determine that they are valid, and use them in two experiments. The

  15. Luminance contours can gate afterimage colors and 'real' colors

    NARCIS (Netherlands)

    Anstis, S.; Vergeer, M.L.T.; Lier, R.J. van

    2012-01-01

    It has long been known that colored images may elicit afterimages in complementary colors. We have already shown (Van Lier, Vergeer, & Anstis, 2009) that one and the same adapting image may result in different afterimage colors, depending on the test contours presented after the colored image. The

  16. Clinical utility of eco-color-power Doppler ultrasonography and contrast enhanced magnetic resonance imaging for interpretation and quantification of joint synovitis: a review.

    Science.gov (United States)

    Carotti, Marina; Galeazzi, Vittoria; Catucci, Francesca; Zappia, Marcello; Arrigoni, Francesco; Barile, Antonio; Giovagnoni, Andrea

    2018-01-19

    With the introduction of new biologics such as anti-TNF-alpha antibodies and other therapies in the treatment of inflammatory arthritis, capable of halting joint destruction and functional disability, there are new pressures on diagnostic and prognostic imaging. Early demonstration of pre-erosive inflammatory features and monitoring of the long-term effects of treatment are becoming increasingly important. Early detection of synovitis offers advantages in terms of allowing early instigation of therapy and may allow the identification of those patients displaying more aggressive disease who might benefit from early intervention with expensive DMARD therapy. Advanced imaging techniques such as ultrasound (US) and magnetic resonance imaging (MRI) have focussed on the demonstration and quantification of synovitis and allow early diagnosis of inflammatory arthropathies such as rheumatoid arthritis (RA) and psoriatic arthritis (PsA). Synovitis represents a potential surrogate measure of disease activity that can be monitored using either MRI or US; the techniques have, generally, focused on monitoring synovial volume or quality as assessed by its vascularity. However to achieve these goals, standardisation and validation of US and MRI are required to ensure accurate diagnosis, reproducibility and reliability. Each modality has different strengths and weaknesses and levels of validation. This article aims to increase the awareness of radiologists and rheumatologists about this field and to encourage them to participate and contribute to the ongoing development of these modalities. Without this collaboration, it is unlikely that these modalities will reach their full potential in the field of rheumatological imaging. This review is in two parts. The first part addresses the role of US and colour or power Doppler sonography (PDUS) in the detection and monitoring of synovitis in inflammatory arthropathies. The second part will look at advanced MR imaging and Dynamic contrast

  17. Quantum color image watermarking based on Arnold transformation and LSB steganography

    Science.gov (United States)

    Zhou, Ri-Gui; Hu, Wenwen; Fan, Ping; Luo, Gaofeng

    In this paper, a quantum color image watermarking scheme is proposed through twice-scrambling of Arnold transformations and steganography of least significant bit (LSB). Both carrier image and watermark images are represented by the novel quantum representation of color digital images model (NCQI). The image sizes for carrier and watermark are assumed to be 2n×2n and 2n‑1×2n‑1, respectively. At first, the watermark is scrambled into a disordered form through image preprocessing technique of exchanging the image pixel position and altering the color information based on Arnold transforms, simultaneously. Then, the scrambled watermark with 2n‑1×2n‑1 image size and 24-qubit grayscale is further expanded to an image with size 2n×2n and 6-qubit grayscale using the nearest-neighbor interpolation method. Finally, the scrambled and expanded watermark is embedded into the carrier by steganography of LSB scheme, and a key image with 2n×2n size and 3-qubit information is generated at the meantime, which only can use the key image to retrieve the original watermark. The extraction of watermark is the reverse process of embedding, which is achieved by applying a sequence of operations in the reverse order. Simulation-based experimental results involving different carrier and watermark images (i.e. conventional or non-quantum) are simulated based on the classical computer’s MATLAB 2014b software, which illustrates that the present method has a good performance in terms of three items: visual quality, robustness and steganography capacity.

  18. Evaluation of mitral regurgitation by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kobayashi, Shiro; Kishi, Naohiro; Kumai, Toshihiko

    1993-01-01

    Valvular regurgitation can be detected as a region of signal loss ('flow void') by cardiac cine magnetic resonance (MR) imaging. Cine MR images of 36 patients with mitral regurgitation caused by mitral valve prolapse (MVP) and non-MVP were evaluated and compared with color Doppler flow images. The direction, distance, area and timing of flow void were detected in all patients in several different planes at mitral level with a 0.5 Tesla superconducting magnet by an ECG-gated fast field echo technique. In 23 of the 36 patients contiguous multiple transaxial images were also obtained to calculate the volumes of flow void and the left atrium. The direction of flow void tended to deviate to the opposite side within the left atrium in MVP. The frame showing maximal area of flow void was demonstrated in mid-systole in 24 of the 36 patients (67%). The distance, area and volume of flow void were concordant with the grade from color Doppler flow images. The volumes of flow void and the left atrium correlated (n=19, r=0.74, p<0.05) in MVP. In conclusion, cine MR images in several different planes or contiguous multiple slices are useful in determining spatial orientation and the extent and timing of mitral regurgitation noninvasively. Furthermore, calculation of the volume of flow void enables the assessment of the semiquantitation of mitral regurgitation. (author)

  19. A method for evaluating image quality of monochrome and color displays based on luminance by use of a commercially available color digital camera

    Energy Technology Data Exchange (ETDEWEB)

    Tokurei, Shogo, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582, Japan and Department of Radiology, Yamaguchi University Hospital, 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Morishita, Junji, E-mail: shogo.tokurei@gmail.com, E-mail: junjim@med.kyushu-u.ac.jp [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Fukuoka 812-8582 (Japan)

    2015-08-15

    Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signals for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The authors

  20. Identification of primary thyroid lymphoma with medical imaging: A case report and review of the literature.

    Science.gov (United States)

    Wang, Jia-Huan; Chen, Liang; Ren, Ke

    2014-12-01

    Primary thyroid lymphoma (PTL) is a rare thyroid malignancy. Clinical diagnosis of PTL may not be easily established based on imaging studies, as the imaging features of PTL are similar to those of lymphocytic thyroiditis and primary thyroid cancer. The present study describes the case of a patient who was confirmed to have PTL by intra-operative pathological diagnosis. On color Doppler ultrasound, the PTL was shown as a significantly enlarged thyroid with reduced gland echoes. Color Doppler flow imaging showed increased blood flow. By computed tomography, the thyroid was revealed to be enlarged with reduced tissue density, particularly in the left lobe and the isthmus. In addition, calcified spots and swollen lymph nodes were evident. The clinical history of the patient was obtained and the imaging results were retrospectively analyzed. The imaging features of PTL were investigated through reviewing the literature. PTL exhibits specific features on medical imaging that aid in distinguishing it from other thyroid diseases. PTL exhibits specific features on medical imaging that aid in distinguishing PTL from other thyroid diseases, which may aid the support for clinical diagnosis and improve the clinical accuracy.

  1. A Robust Color Image Watermarking Scheme Using Entropy and QR Decomposition

    Directory of Open Access Journals (Sweden)

    L. Laur

    2015-12-01

    Full Text Available Internet has affected our everyday life drastically. Expansive volumes of information are exchanged over the Internet consistently which causes numerous security concerns. Issues like content identification, document and image security, audience measurement, ownership, copyrights and others can be settled by using digital watermarking. In this work, robust and imperceptible non-blind color image watermarking algorithm is proposed, which benefit from the fact that watermark can be hidden in different color channel which results into further robustness of the proposed technique to attacks. Given method uses some algorithms such as entropy, discrete wavelet transform, Chirp z-transform, orthogonal-triangular decomposition and Singular value decomposition in order to embed the watermark in a color image. Many experiments are performed using well-known signal processing attacks such as histogram equalization, adding noise and compression. Experimental results show that proposed scheme is imperceptible and robust against common signal processing attacks.

  2. Acquisition and visualization techniques for narrow spectral color imaging.

    Science.gov (United States)

    Neumann, László; García, Rafael; Basa, János; Hegedüs, Ramón

    2013-06-01

    This paper introduces a new approach in narrow-band imaging (NBI). Existing NBI techniques generate images by selecting discrete bands over the full visible spectrum or an even wider spectral range. In contrast, here we perform the sampling with filters covering a tight spectral window. This image acquisition method, named narrow spectral imaging, can be particularly useful when optical information is only available within a narrow spectral window, such as in the case of deep-water transmittance, which constitutes the principal motivation of this work. In this study we demonstrate the potential of the proposed photographic technique on nonunderwater scenes recorded under controlled conditions. To this end three multilayer narrow bandpass filters were employed, which transmit at 440, 456, and 470 nm bluish wavelengths, respectively. Since the differences among the images captured in such a narrow spectral window can be extremely small, both image acquisition and visualization require a novel approach. First, high-bit-depth images were acquired with multilayer narrow-band filters either placed in front of the illumination or mounted on the camera lens. Second, a color-mapping method is proposed, using which the input data can be transformed onto the entire display color gamut with a continuous and perceptually nearly uniform mapping, while ensuring optimally high information content for human perception.

  3. The utilization of human color categorization for content-based image retrieval

    NARCIS (Netherlands)

    van den Broek, Egon; Rogowitz, Bernice E.; Kisters, Peter M.F.; Pappas, Thrasyvoulos N.; Vuurpijl, Louis G.

    2004-01-01

    We present the concept of intelligent Content-Based Image Retrieval (iCBIR), which incorporates knowledge concerning human cognition in system development. The present research focuses on the utilization of color categories (or focal colors) for CBIR purposes, in particularly considered to be useful

  4. Multi-Frequency Encoding for Rapid Color Flow and Quadroplex Imaging

    DEFF Research Database (Denmark)

    Oddershede, Niels; Gran, Fredrik; Jensen, Jørgen Arendt

    2007-01-01

    Ultrasonic color flow maps are made by estimating the velocities line by line over the region of interest. For each velocity estimate, multiple repetitions are needed. This sets a limit on the frame rate, which becomes increasingly severe when imaging deeper lying structures or when simultaneously...... acquiring spectrogram data for triplex imaging. This paper proposes a method for decreasing the data acquisition time by simultaneously sampling multiple lines at different spatial positions for the color flow map using narrow band signals with disjoint spectral support. The signals are separated...... in the receiver by filters matched to the emitted waveforms and the autocorrelation estimator is applied. Alternatively, one spectral band can be used for creating a color flow map, while data for a number of spectrograms are acquired simultaneously. Using three disjoint spectral bands, this will result...

  5. Laser Doppler imaging as a tool in the burn wound treatment protocol

    OpenAIRE

    Venclauskiene, Algirda; Basevicius, Algidas; Zacharevskij, Ernest; Vaicekauskas, Vytautas; Rimdeika, Rytis; Lukosevicius, Saulius

    2014-01-01

    Introduction The main treatment of burns is early excision of injured tissues. Aim To compare two different methods of examination of burned patients: clinical burn depth examination (CDE) and laser Doppler imaging (LDI). Material and methods A prospective randomized study of 57 burn patients treated in 2009–2011 was carried out. The burned patients were randomized into a CDE group and an LDI group. The CDE and LDI scan were performed 72 h after injury, with the second and third CDE and LDI s...

  6. Plane wave fast color flow mode imaging

    DEFF Research Database (Denmark)

    Bolic, Ibrahim; Udesen, Jesper; Gran, Fredrik

    2006-01-01

    A new Plane wave fast color flow imaging method (PWM) has been investigated, and performance evaluation of the PWM based on experimental measurements has been made. The results show that it is possible to obtain a CFM image using only 8 echo-pulse emissions for beam to flow angles between 45...... degrees and 75 degrees. Compared to the conventional ultrasound imaging the frame rate is similar to 30 - 60 times higher. The bias, B-est of the velocity profile estimate, based on 8 pulse-echo emissions, is between 3.3% and 6.1% for beam to flow angles between 45 degrees and 75 degrees, and the standard...

  7. Diagnosis of Pentalogy of Cantrell in the First Trimester Using Transvaginal Sonography and Color Doppler

    Directory of Open Access Journals (Sweden)

    Ayşe Figen Türkçapar

    2015-01-01

    Full Text Available We report the prenatal diagnosis of Cantrell syndrome in the first trimester. During a routine transabdominal ultrasonographic examination, a midline supraumbilical abdominal wall defect including herniated liver and ectopia cordis with a large omphalocele containing the intestines and cystic hygroma was incidentally identified at the 12th week of gestation. A transvaginal sonography examination revealed a severe lumbosacral scoliosis in addition to the inability to visualize the abdominal aorta which was indicative of a severe intracardiac defect. The parents opted for pregnancy to be terminated. In this case report, we discuss the complementary role of transvaginal sonography and Doppler imaging in the diagnosis of Cantrell syndrome in early pregnancy.

  8. Modeling human color categorization: Color discrimination and color memory

    OpenAIRE

    Heskes, T.; van den Broek, Egon; Lucas, P.; Hendriks, Maria A.; Vuurpijl, L.G.; Puts, M.J.H.; Wiegerinck, W.

    2003-01-01

    Color matching in Content-Based Image Retrieval is done using a color space and measuring distances between colors. Such an approach yields non-intuitive results for the user. We introduce color categories (or focal colors), determine that they are valid, and use them in two experiments. The experiments conducted prove the difference between color categorization by the cognitive processes color discrimination and color memory. In addition, they yield a Color Look-Up Table, which can improve c...

  9. Role of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation in detecting fetal pulmonary veins.

    Science.gov (United States)

    Sun, Xue; Zhang, Ying; Fan, Miao; Wang, Yu; Wang, Meilian; Siddiqui, Faiza Amber; Sun, Wei; Sun, Feifei; Zhang, Dongyu; Lei, Wenjia; Hu, Guyue

    2017-06-01

    Prenatal diagnosis of fetal total anomalous pulmonary vein connection (TAPVC) remains challenging for most screening sonographers. The purpose of this study was to evaluate the use of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation (4D-HDFI) in identifying pulmonary veins in normal and TAPVC fetuses. We retrospectively reviewed and performed 4D-HDFI in 204 normal and 12 fetuses with confirmed diagnosis of TAPVC. Cardiac volumes were available for postanalysis to obtain 4D-rendered images of the pulmonary veins. For the normal fetuses, two other traditional modalities including color Doppler and HDFI were used to detect the number of pulmonary veins and comparisons were made between each of these traditional methods and 4D-HDFI. For conventional echocardiography, HDFI modality was superior to color Doppler in detecting more pulmonary veins in normal fetuses throughout the gestational period. 4D-HDFI was the best method during the second trimester of pregnancy in identifying normal fetal pulmonary veins. 4D-HDFI images vividly depicted the figure, course, and drainage of pulmonary veins in both normal and TAPVC fetuses. HDFI and the advanced 4D-HDFI technique could facilitate identification of the anatomical features of pulmonary veins in both normal and TAPVC fetuses; 4D-HDFI therefore provides additional and more precise information than conventional echocardiography techniques. © 2017, Wiley Periodicals, Inc.

  10. [Design Method Analysis and Performance Comparison of Wall Filter for Ultrasound Color Flow Imaging].

    Science.gov (United States)

    Wang, Lutao; Xiao, Jun; Chai, Hua

    2015-08-01

    The successful suppression of clutter arising from stationary or slowly moving tissue is one of the key issues in medical ultrasound color blood imaging. Remaining clutter may cause bias in the mean blood frequency estimation and results in a potentially misleading description of blood-flow. In this paper, based on the principle of general wall-filter, the design process of three classes of filters, infinitely impulse response with projection initialization (Prj-IIR), polynomials regression (Pol-Reg), and eigen-based filters are previewed and analyzed. The performance of the filters was assessed by calculating the bias and variance of a mean blood velocity using a standard autocorrelation estimator. Simulation results show that the performance of Pol-Reg filter is similar to Prj-IIR filters. Both of them can offer accurate estimation of mean blood flow speed under steady clutter conditions, and the clutter rejection ability can be enhanced by increasing the ensemble size of Doppler vector. Eigen-based filters can effectively remove the non-stationary clutter component, and further improve the estimation accuracy for low speed blood flow signals. There is also no significant increase in computation complexity for eigen-based filters when the ensemble size is less than 10.

  11. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  12. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2011-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  13. A simple methodology for obtaining X-ray color images in scanning electron microscopy

    International Nuclear Information System (INIS)

    Veiga, M.M. da; Pietroluongo, L.R.V.

    1985-01-01

    A simple methodology for obtaining at least 3 elements X-ray images in only one photography is described. The fluorescent X-ray image is obtained from scanning electron microscopy with energy dispersion analysis system. The change of detector analytic channels, color cellophane foils and color films are used sequentially. (M.C.K.) [pt

  14. Moving Target Detection With Compact Laser Doppler Radar

    Science.gov (United States)

    Sepp, G.; Breining, A.; Eisfeld, W.; Knopp, R.; Lill, E.; Wagner, D.

    1989-12-01

    This paper describes an experimental integrated optronic system for detection and tracking of moving objects. The system is based on a CO2 waveguide laser Doppler ra-dar with homodyne receiver and galvanometer mirror beam scanner. A "hot spot" seeker consisting of a thermal imager with image processor transmits the coordinates of IR-emitting, i.e. potentially powered, objects to the laser radar scanner. The scanner addresses these "hot" locations operating in a large field-of-view (FOV) random ac-cess mode. Hot spots exhibiting a Doppler shifted laser signal are indicated in the thermal image by velocity-to-colour encoded markers. After switching to a small FOV scanning mode, the laser Doppler radar is used to track fast moving objects. Labora-tory and field experiments with moving objects including rotating discs, automobiles and missiles are described.

  15. Hyperspectral imaging of cuttlefish camouflage indicates good color match in the eyes of fish predators.

    Science.gov (United States)

    Chiao, Chuan-Chin; Wickiser, J Kenneth; Allen, Justine J; Genter, Brock; Hanlon, Roger T

    2011-05-31

    Camouflage is a widespread phenomenon throughout nature and an important antipredator tactic in natural selection. Many visual predators have keen color perception, and thus camouflage patterns should provide some degree of color matching in addition to other visual factors such as pattern, contrast, and texture. Quantifying camouflage effectiveness in the eyes of the predator is a challenge from the perspectives of both biology and optical imaging technology. Here we take advantage of hyperspectral imaging (HSI), which records full-spectrum light data, to simultaneously visualize color match and pattern match in the spectral and the spatial domains, respectively. Cuttlefish can dynamically camouflage themselves on any natural substrate and, despite their colorblindness, produce body patterns that appear to have high-fidelity color matches to the substrate when viewed directly by humans or with RGB images. Live camouflaged cuttlefish on natural backgrounds were imaged using HSI, and subsequent spectral analysis revealed that most reflectance spectra of individual cuttlefish and substrates were similar, rendering the color match possible. Modeling color vision of potential di- and trichromatic fish predators of cuttlefish corroborated the spectral match analysis and demonstrated that camouflaged cuttlefish show good color match as well as pattern match in the eyes of fish predators. These findings (i) indicate the strong potential of HSI technology to enhance studies of biological coloration and (ii) provide supporting evidence that cuttlefish can produce color-coordinated camouflage on natural substrates despite lacking color vision.

  16. PROCEDURES FOR ACCURATE PRODUCTION OF COLOR IMAGES FROM SATELLITE OR AIRCRAFT MULTISPECTRAL DIGITAL DATA.

    Science.gov (United States)

    Duval, Joseph S.

    1985-01-01

    Because the display and interpretation of satellite and aircraft remote-sensing data make extensive use of color film products, accurate reproduction of the color images is important. To achieve accurate color reproduction, the exposure and chemical processing of the film must be monitored and controlled. By using a combination of sensitometry, densitometry, and transfer functions that control film response curves, all of the different steps in the making of film images can be monitored and controlled. Because a sensitometer produces a calibrated exposure, the resulting step wedge can be used to monitor the chemical processing of the film. Step wedges put on film by image recording machines provide a means of monitoring the film exposure and color balance of the machines.

  17. Primary chronic venous insufficiency of the lower extremities: preoperative color duplex Doppler ultrasound study

    International Nuclear Information System (INIS)

    Selfa, S.; Diago, T.; Ricart, M.; Chulia, R.; Martin, F.

    2000-01-01

    To asses the role of color duplex Doppler ultrasound (CDU) in the preoperative study of patients with varicose veins in lower extremities. We employed CDU to examine varicose veins in 342 lower limbs, assessing reflux in saphenous veins (SV), deep venous system (DVS) and perforating veins (PV). We analyzed the relationship between the anatomical extent of the reflux and the clinical findings. Insufficiency of the superficial venous system alone was uncommon, occurring in only 10.8% of the limbs examined. Reflux was observed in SV and PV in 48.2% of the legs. It was detected in all three systems in 29.2% of cases. The presence of reflux in more than one system and more than one value was associated with increased clinical severity. The site of venous reflux in lower extremities with varicose veins varies. Greater clinical severity is observed in the presence of more marked reflux in the DVS and PV. CDU provides anatomic and functional data on the three venous systems of the lower limbs, allowing an individualized therapeutic surgery. Preoperative localization of incompetent PV by means of CDU facilities their ligation. CDU is the technique of choice for the preoperative examination of the venous systems of patients with varicose veins. (Author)

  18. Improving scale invariant feature transform with local color contrastive descriptor for image classification

    Science.gov (United States)

    Guo, Sheng; Huang, Weilin; Qiao, Yu

    2017-01-01

    Image representation and classification are two fundamental tasks toward version understanding. Shape and texture provide two key features for visual representation and have been widely exploited in a number of successful local descriptors, e.g., scale invariant feature transform (SIFT), local binary pattern descriptor, and histogram of oriented gradient. Unlike these gradient-based descriptors, this paper presents a simple yet efficient local descriptor, named local color contrastive descriptor (LCCD), which captures the contrastive aspects among local regions or color channels for image representation. LCCD is partly inspired by the neural science facts that color contrast plays important roles in visual perception and there exist strong linkages between color and shape. We leverage f-divergence as a robust measure to estimate the contrastive features between different spatial locations and multiple channels. Our descriptor enriches local image representation with both color and contrast information. Due to that LCCD does not explore any gradient information, individual LCCD does not yield strong performance. But we verified experimentally that LCCD can compensate strongly SIFT. Extensive experimental results on image classification show that our descriptor improves the performance of SIFT substantially by combination on three challenging benchmarks, including MIT Indoor-67 database, SUN397, and PASCAL VOC 2007.

  19. Computer-Generated Abstract Paintings Oriented by the Color Composition of Images

    Directory of Open Access Journals (Sweden)

    Mao Li

    2017-06-01

    Full Text Available Designers and artists often require reference images at authoring time. The emergence of computer technology has provided new conditions and possibilities for artistic creation and research. It has also expanded the forms of artistic expression and attracted many artists, designers and computer experts to explore different artistic directions and collaborate with one another. In this paper, we present an efficient k-means-based method to segment the colors of an original picture to analyze the composition ratio of the color information and calculate individual color areas that are associated with their sizes. This information is transformed into regular geometries to reconstruct the colors of the picture to generate abstract images. Furthermore, we designed an application system using the proposed method and generated many works; some artists and designers have used it as an auxiliary tool for art and design creation. The experimental results of datasets demonstrate the effectiveness of our method and can give us inspiration for our work.

  20. Evaluation of valvular regurgitation by cine magnetic resonance imaging in patients with various cardiac diseases

    International Nuclear Information System (INIS)

    Kubota, Shuuhei; Nishimura, Tsunehiko

    1990-01-01

    In order to evaluate the clinical value and limitation of magnetic resonance imaging (MRI) for detection and quantification of valvular regurgitation, 98 patients with various cardiac diseases were studied by cine MRI and the results were compared with contrast angiography and doppler color-flow imaging. Cine MRI was carried out using FLASH (fast low angle shot) which employs TE of 10∼20 msec and TR of 30∼40 msec. 22 transverse tomograms per cardiac cycle with a slice thickness of 10 mm were obtained at the level of atrium and ventricle. The jet of valvular regurgitation was easily seen as a discrete are of low signal with cine MRI. Identification of the regurgitation and its severity were visually evaluated based on the relative size of the regurgitant jet from the incompetent valve orifice. Using contrast angiography as a gold standard, the sensitivity of cine MRI for detecting mitral regurgitation was 83% and was 94% for aortic regurgitation, with the specificity of 82% and 100%, respectively. For mitral requrgitation and aortic regurgitation, evaluation by cine MRI and severity agreed well with contrast angiography. By the comparative study with doppler color-flow imaging, relatively good agreement was found between the two methods in detection and quantitative evaluation of valvular regurgitation in any of four valves. Cine MRI was suggested to be useful for both the detection and semiquantification of valvular regurgitation in generally, but its clinical limitation at this point was also found because, 1)its images are not acquired in real times, as in contrast angiography or doppler color-flow imaging, but are compiled from the cumulative information from 128 heart beats, 2)the evaluation of regurgitation is made from only two-dimensional transverse tomograms. (author)